SIO Argo Site:
Pump Diagnostics Page   



Serial= 8679 WMO= 5905694

Return

←PreviousNext→

Cycle 37 GMT 19/ 6/2019 2:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 31 15.18 459 216 0.22 / 140.15 2 2
2 12 1158.12 3 15.27 1901 87 0.30 / 140.24 2 2
3 7 2001.32 34 14.88 2852 1443 1.75 / 141.68 2 2
4 13 1479.92 19 14.93 2251 639 2.38 / 142.32 2 2
5 13 966.44 19 15.01 1611 459 2.84 / 142.78 2 3
6 13 279.52 19 15.17 729 210 3.05 / 142.99 2 3
7 13 79.64 19 15.22 442 128 3.18 / 143.12 2 2
8 13 19.40 19 15.23 352 102 3.28 / 143.22 2 2
9 8 0.08 165 15.20 318 798 4.08 / 144.02 2 9
Average= 3.79
(KJ/cycle)

Cycle 36 GMT 9/ 6/2019 4:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 31 15.17 452 213 0.21 / 136.18 2 2
2 12 1162.24 3 15.27 1920 88 0.30 / 136.27 2 2
3 7 2001.72 34 14.89 2841 1438 1.74 / 137.71 2 2
4 13 1474.48 19 14.93 2233 633 2.37 / 138.34 2 3
5 13 950.60 19 15.02 1593 455 2.83 / 138.80 2 3
6 13 258.20 19 15.18 704 203 3.03 / 139.00 2 3
7 13 72.04 19 15.23 436 126 3.16 / 139.13 2 2
8 8 0.00 165 15.21 324 813 3.97 / 139.94 2 4
Average= 3.78
(KJ/cycle)

Cycle 35 GMT 30/ 5/2019 6: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 31 15.18 447 210 0.21 / 132.15 2 2
2 12 1140.76 3 15.28 1866 86 0.30 / 132.23 2 2
3 7 2002.40 34 14.89 2836 1436 1.73 / 133.67 2 2
4 13 1477.84 19 14.93 2248 638 2.37 / 134.30 2 2
5 13 816.60 19 15.05 1426 408 2.78 / 134.71 2 3
6 13 292.72 19 15.17 753 217 2.99 / 134.93 2 3
7 13 73.84 19 15.23 437 126 3.12 / 135.06 2 2
8 13 20.60 19 15.24 356 103 3.22 / 135.16 2 2
9 8 0.04 165 15.20 323 810 4.03 / 135.97 2 7
Average= 3.78
(KJ/cycle)

Cycle 34 GMT 20/ 5/2019 7:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 31 15.18 450 212 0.21 / 128.20 2 2
2 12 1151.64 3 15.28 1889 87 0.30 / 128.29 2 2
3 7 2003.80 34 14.89 2846 1441 1.74 / 129.73 2 2
4 13 1481.36 19 14.94 2242 636 2.38 / 130.37 2 2
5 13 939.88 19 15.02 1577 450 2.83 / 130.82 2 2
6 13 245.56 19 15.19 681 197 3.02 / 131.01 2 2
7 13 68.56 19 15.23 431 125 3.15 / 131.14 2 2
8 8 -0.04 165 15.22 318 799 3.95 / 131.94 2 5
Average= 3.77
(KJ/cycle)

Cycle 33 GMT 10/ 5/2019 9: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 31 15.18 463 218 0.22 / 124.21 2 2
2 12 1160.12 3 15.28 1900 87 0.30 / 124.30 2 2
3 7 2003.32 34 14.89 2843 1439 1.74 / 125.73 2 2
4 13 1485.20 19 14.94 2242 636 2.38 / 126.37 2 2
5 13 824.24 19 15.06 1431 409 2.79 / 126.78 2 3
6 13 187.16 19 15.21 601 174 2.96 / 126.95 2 2
7 13 64.88 19 15.24 417 121 3.08 / 127.07 2 2
8 13 35.96 19 15.24 379 110 3.19 / 127.18 2 2
9 8 0.12 165 15.21 321 806 4.00 / 127.99 2 6
Average= 3.76
(KJ/cycle)

Cycle 32 GMT 30/ 4/2019 10:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 31 15.19 449 211 0.21 / 120.15 2 2
2 12 1161.04 3 15.28 1905 87 0.30 / 120.24 2 2
3 7 2005.32 34 14.90 2850 1444 1.74 / 121.68 2 2
4 13 1486.32 19 14.94 2253 640 2.38 / 122.32 2 2
5 13 810.52 19 15.06 1416 405 2.79 / 122.73 2 2
6 13 301.40 19 15.18 759 219 3.01 / 122.95 2 3
7 13 76.60 19 15.24 444 129 3.13 / 123.08 2 2
8 13 20.68 19 15.24 356 103 3.24 / 123.18 2 2
9 8 0.04 165 15.21 323 811 4.05 / 123.99 2 6
Average= 3.76
(KJ/cycle)

Cycle 31 GMT 20/ 4/2019 12: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 31 15.19 455 214 0.21 / 116.25 2 2
2 12 1147.68 3 15.28 1899 87 0.30 / 116.33 2 2
3 7 2003.24 34 14.90 2850 1444 1.75 / 117.78 2 2
4 13 1344.16 19 14.98 2075 591 2.34 / 118.37 2 2
5 13 853.32 19 15.05 1472 421 2.76 / 118.79 2 3
6 13 188.48 19 15.21 611 177 2.93 / 118.96 2 2
7 13 72.48 19 15.24 431 125 3.06 / 119.09 2 2
8 8 0.12 175 15.22 320 852 3.91 / 119.94 2 6
Average= 3.75
(KJ/cycle)

Cycle 30 GMT 10/ 4/2019 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 31 15.19 452 213 0.21 / 112.20 2 2
2 12 1159.60 3 15.29 1911 88 0.30 / 112.29 2 2
3 7 2002.32 34 14.91 2853 1446 1.75 / 113.73 2 2
4 13 1342.72 18 14.99 2092 564 2.31 / 114.30 2 2
5 13 864.84 18 15.06 1494 405 2.72 / 114.70 2 3
6 13 351.08 18 15.17 834 228 2.94 / 114.93 2 3
7 13 87.00 18 15.24 465 128 3.07 / 115.06 2 2
8 13 23.20 18 15.25 365 100 3.17 / 115.16 2 2
9 8 0.08 175 15.22 328 874 4.05 / 116.03 2 7
Average= 3.74
(KJ/cycle)

Cycle 29 GMT 31/ 3/2019 14:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 31 15.20 446 210 0.21 / 108.10 2 2
2 12 1163.96 3 15.29 1919 88 0.30 / 108.19 2 2
3 7 2002.00 34 14.90 2850 1444 1.74 / 109.63 2 2
4 13 1482.36 18 14.96 2258 608 2.35 / 110.24 2 2
5 13 958.80 18 15.04 1616 437 2.79 / 110.68 2 3
6 13 291.04 18 15.19 756 207 2.99 / 110.88 2 2
7 13 75.40 18 15.25 450 124 3.12 / 111.01 2 2
8 13 21.40 18 15.25 367 101 3.22 / 111.11 2 2
9 8 0.00 175 15.22 330 879 4.10 / 111.99 2 6
Average= 3.73
(KJ/cycle)

Cycle 28 GMT 21/ 3/2019 16:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 31 15.20 446 210 0.21 / 104.20 2 2
2 12 1168.00 3 15.30 1912 88 0.30 / 104.28 2 2
3 7 2001.28 34 14.91 2844 1442 1.74 / 105.73 2 2
4 13 1487.00 18 14.97 2266 611 2.35 / 106.34 2 2
5 13 835.16 18 15.08 1454 395 2.74 / 106.73 2 2
6 13 207.72 18 15.22 638 175 2.92 / 106.91 2 2
7 13 71.64 18 15.25 432 119 3.04 / 107.03 2 2
8 8 0.04 175 15.23 324 864 3.90 / 107.89 2 9
Average= 3.72
(KJ/cycle)

Cycle 27 GMT 11/ 3/2019 17:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 31 15.21 457 215 0.22 / 100.12 2 2
2 12 1159.24 3 15.31 1905 87 0.30 / 100.21 2 2
3 7 2004.20 34 14.91 2844 1442 1.74 / 101.65 2 2
4 13 1494.48 17 14.97 2276 579 2.32 / 102.23 2 2
5 13 977.40 17 15.05 1634 418 2.74 / 102.64 2 3
6 13 465.80 17 15.16 986 254 3.00 / 102.90 2 3
7 13 86.24 17 15.25 457 118 3.11 / 103.02 2 2
8 13 47.28 17 15.26 400 104 3.22 / 103.12 2 2
9 8 0.00 175 15.23 325 866 4.08 / 103.99 2 6
Average= 3.71
(KJ/cycle)

Cycle 26 GMT 1/ 3/2019 19:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 31 15.20 448 211 0.21 / 96.17 2 2
2 12 1164.24 3 15.31 1908 88 0.30 / 96.26 2 2
3 7 2004.52 34 14.92 2860 1451 1.75 / 97.71 2 2
4 13 1507.24 17 14.97 2283 581 2.33 / 98.29 2 2
5 13 979.76 17 15.05 1636 419 2.75 / 98.71 2 2
6 13 320.36 17 15.20 786 203 2.95 / 98.91 2 2
7 13 88.72 17 15.25 466 121 3.07 / 99.04 2 2
8 8 0.08 175 15.24 325 867 3.94 / 99.90 2 6
Average= 3.70
(KJ/cycle)

Cycle 25 GMT 19/ 2/2019 20:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 31 15.21 453 214 0.21 / 92.17 2 2
2 12 1146.08 2 15.32 1889 58 0.27 / 92.23 2 2
3 7 2004.28 34 14.92 2861 1451 1.72 / 93.68 2 2
4 13 1500.08 17 14.98 2274 579 2.30 / 94.26 2 2
5 13 979.24 17 15.05 1628 417 2.72 / 94.68 2 2
6 13 322.44 17 15.20 786 203 2.92 / 94.88 2 3
7 13 90.80 17 15.26 465 121 3.04 / 95.00 2 2
8 13 24.56 17 15.27 368 96 3.14 / 95.10 2 2
9 8 0.00 175 15.24 325 867 4.00 / 95.96 2 11
Average= 3.69
(KJ/cycle)

Cycle 24 GMT 9/ 2/2019 22:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 31 15.22 457 216 0.22 / 88.08 2 2
2 12 1154.44 2 15.33 1905 58 0.27 / 88.14 2 2
3 7 2004.92 34 14.93 2854 1449 1.72 / 89.59 2 2
4 13 1665.60 17 14.95 2472 628 2.35 / 90.22 2 2
5 13 971.44 17 15.06 1623 416 2.77 / 90.63 2 3
6 13 458.64 17 15.17 970 250 3.02 / 90.88 2 3
7 13 92.64 17 15.26 464 120 3.14 / 91.00 2 2
8 13 24.92 17 15.27 365 95 3.23 / 91.10 2 2
9 8 0.08 175 15.24 322 859 4.09 / 91.96 2 7
Average= 3.68
(KJ/cycle)

Cycle 23 GMT 30/ 1/2019 23:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 31 15.22 475 224 0.22 / 84.14 2 2
2 12 1144.32 2 15.34 1894 58 0.28 / 84.19 2 2
3 7 2001.96 34 14.93 2850 1447 1.73 / 85.64 2 2
4 13 1500.88 17 14.98 2283 581 2.31 / 86.22 2 2
5 13 975.04 17 15.06 1629 417 2.73 / 86.64 2 2
6 13 454.16 17 15.17 970 250 2.98 / 86.89 2 3
7 13 86.28 17 15.26 457 119 3.10 / 87.01 2 2
8 8 0.12 175 15.25 322 859 3.96 / 87.87 2 5
Average= 3.66
(KJ/cycle)

Cycle 22 GMT 21/ 1/2019 1:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 31 15.22 454 214 0.21 / 80.24 2 2
2 12 1137.68 2 15.34 1880 58 0.27 / 80.29 2 2
3 7 2003.08 34 14.94 2847 1446 1.72 / 81.74 2 2
4 13 1486.60 17 14.99 2255 575 2.29 / 82.31 2 2
5 13 968.16 17 15.07 1618 415 2.71 / 82.73 2 3
6 13 313.40 17 15.22 778 201 2.91 / 82.93 2 2
7 13 82.44 17 15.27 452 117 3.03 / 83.05 2 2
8 8 0.12 175 15.25 324 865 3.89 / 83.91 2 5
Average= 3.65
(KJ/cycle)

Cycle 21 GMT 11/ 1/2019 3: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 31 15.23 455 215 0.21 / 76.39 2 2
2 12 1156.60 2 15.33 1903 58 0.27 / 76.45 2 2
3 7 2002.44 34 14.94 2835 1440 1.71 / 77.89 2 2
4 13 1344.24 17 15.02 2088 533 2.25 / 78.42 2 2
5 13 877.24 17 15.09 1508 387 2.63 / 78.81 2 2
6 13 365.32 17 15.20 851 220 2.85 / 79.03 2 3
7 13 96.88 17 15.26 475 123 2.98 / 79.15 2 2
8 8 0.08 175 15.25 326 870 3.85 / 80.02 2 6
Average= 3.64
(KJ/cycle)

Cycle 20 GMT 1/ 1/2019 4:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 31 15.22 455 215 0.21 / 72.51 2 2
2 12 1161.32 2 15.33 1920 59 0.27 / 72.57 2 2
3 7 2006.04 34 14.94 2862 1454 1.73 / 74.02 2 2
4 13 1489.68 17 15.00 2259 576 2.30 / 74.60 2 2
5 13 840.12 17 15.11 1459 375 2.68 / 74.97 2 2
6 13 346.80 17 15.21 823 213 2.89 / 75.18 2 2
7 13 89.84 17 15.27 464 120 3.01 / 75.30 2 2
8 8 0.04 175 15.26 326 871 3.88 / 76.18 2 5
Average= 3.63
(KJ/cycle)

Cycle 19 GMT 22/12/2018 6:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 31 15.21 453 214 0.21 / 68.46 2 2
2 12 1160.32 2 15.34 1914 59 0.27 / 68.52 2 2
3 7 2002.32 34 14.95 2841 1444 1.72 / 69.96 2 2
4 13 1651.40 17 14.98 2449 624 2.34 / 70.59 2 2
5 13 945.04 17 15.09 1587 407 2.75 / 71.00 2 2
6 13 428.12 17 15.19 934 241 2.99 / 71.24 2 3
7 13 81.36 17 15.28 446 116 3.10 / 71.35 2 2
8 13 24.32 17 15.29 365 95 3.20 / 71.45 2 2
9 8 0.04 170 15.26 326 846 4.04 / 72.29 2 5
Average= 3.61
(KJ/cycle)

Cycle 18 GMT 12/12/2018 8:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 31 15.23 470 222 0.22 / 64.06 2 2
2 12 1158.28 2 15.34 1892 58 0.28 / 64.12 2 2
3 7 2002.60 34 14.95 2844 1446 1.73 / 65.56 2 2
4 13 1496.36 17 15.01 2268 579 2.30 / 66.14 2 2
5 13 974.36 17 15.08 1628 417 2.72 / 66.56 2 2
6 13 437.08 17 15.19 949 245 2.97 / 66.80 2 3
7 13 118.52 17 15.27 514 133 3.10 / 66.94 2 2
8 13 27.44 17 15.29 380 99 3.20 / 67.04 2 2
9 8 0.12 170 15.26 333 864 4.06 / 67.90 2 6
10 14 0.12 70 15.22 326 347 4.41 / 68.25 2 9
Average= 3.59
(KJ/cycle)

Cycle 17 GMT 2/12/2018 9:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 31 15.24 466 220 0.22 / 60.23 2 2
2 12 1151.56 2 15.34 1896 58 0.28 / 60.29 2 2
3 7 2005.16 34 14.96 2844 1447 1.72 / 61.74 2 2
4 13 1341.08 17 15.04 2086 533 2.26 / 62.27 2 2
5 13 867.44 17 15.11 1497 385 2.64 / 62.65 2 2
6 13 372.64 17 15.21 856 221 2.86 / 62.88 2 3
7 13 93.96 17 15.28 472 123 2.99 / 63.00 2 2
8 8 0.04 170 15.26 324 841 3.83 / 63.84 2 6
Average= 3.55
(KJ/cycle)

Cycle 16 GMT 22/11/2018 11:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 30 15.24 463 212 0.21 / 56.36 2 2
2 12 1158.56 2 15.34 1920 59 0.27 / 56.42 2 2
3 7 2003.68 34 14.96 2844 1447 1.72 / 57.87 2 2
4 13 1481.36 17 15.01 2256 576 2.29 / 58.44 2 2
5 13 971.76 17 15.09 1623 416 2.71 / 58.86 2 2
6 13 307.76 17 15.23 769 199 2.91 / 59.06 2 2
7 13 84.76 17 15.29 451 117 3.03 / 59.18 2 2
8 8 0.08 170 15.27 321 833 3.86 / 60.01 2 5
Average= 3.53
(KJ/cycle)

Cycle 15 GMT 12/11/2018 13:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 30 15.24 452 207 0.21 / 52.49 2 2
2 12 1313.48 2 15.31 2106 64 0.27 / 52.56 2 2
3 7 2005.44 34 14.96 2852 1451 1.72 / 54.01 2 2
4 13 1490.52 17 15.02 2271 580 2.30 / 54.59 2 2
5 13 848.00 17 15.12 1479 380 2.68 / 54.97 2 2
6 13 369.16 17 15.22 858 222 2.90 / 55.19 2 2
7 13 104.96 17 15.28 492 128 3.03 / 55.32 2 2
8 8 -0.08 165 15.27 331 834 3.87 / 56.15 2 5
Average= 3.51
(KJ/cycle)

Cycle 14 GMT 2/11/2018 14:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 30 15.24 449 205 0.21 / 48.59 2 2
2 12 1308.52 2 15.31 2103 64 0.27 / 48.65 2 2
3 7 2002.48 34 14.96 2845 1447 1.72 / 50.10 2 2
4 13 1483.40 17 15.02 2250 575 2.29 / 50.67 2 2
5 13 965.40 17 15.10 1618 415 2.71 / 51.09 2 2
6 13 432.56 17 15.21 936 242 2.95 / 51.33 2 2
7 13 116.76 17 15.28 507 132 3.08 / 51.46 2 2
8 8 0.04 165 15.27 327 824 3.90 / 52.29 2 5
Average= 3.49
(KJ/cycle)

Cycle 13 GMT 23/10/2018 16:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 30 15.25 453 207 0.21 / 44.67 2 2
2 12 1315.40 2 15.31 2106 64 0.27 / 44.73 2 2
3 7 2002.40 38 14.95 2836 1611 1.88 / 46.35 2 2
4 13 1457.60 17 15.02 2221 567 2.45 / 46.91 2 2
5 13 785.72 17 15.14 1386 357 2.81 / 47.27 2 2
6 13 282.24 17 15.25 733 190 3.00 / 47.46 2 2
7 13 83.20 17 15.29 445 116 3.11 / 47.58 2 2
8 8 0.04 165 15.28 320 807 3.92 / 48.38 2 5
Average= 3.46
(KJ/cycle)

Cycle 12 GMT 13/10/2018 18:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 30 15.24 471 215 0.22 / 40.81 2 2
2 12 1290.56 2 15.33 2080 64 0.28 / 40.88 2 2
3 7 2002.40 38 14.95 2853 1621 1.90 / 42.50 2 2
4 13 1308.44 17 15.06 2040 522 2.42 / 43.02 2 2
5 13 806.68 17 15.14 1416 364 2.79 / 43.38 2 2
6 13 184.40 17 15.27 602 156 2.94 / 43.54 2 2
7 13 100.20 17 15.29 471 122 3.07 / 43.66 2 2
8 8 0.12 165 15.28 318 802 3.87 / 44.46 2 4
Average= 3.42
(KJ/cycle)

Cycle 11 GMT 3/10/2018 19:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 30 15.24 456 208 0.21 / 36.78 2 2
2 3 1025.12 1 15.30 1756 27 0.24 / 36.81 2 2
3 7 2001.80 40 14.95 2840 1698 1.93 / 38.51 2 2
4 13 1290.76 18 15.06 2031 551 2.48 / 39.06 2 2
5 13 790.52 18 15.13 1401 382 2.87 / 39.44 2 2
6 13 251.12 18 15.25 701 192 3.06 / 39.63 2 2
7 13 67.56 18 15.30 435 120 3.18 / 39.75 2 2
8 8 0.12 165 15.28 334 842 4.02 / 40.60 2 3
Average= 3.38
(KJ/cycle)

Cycle 10 GMT 23/ 9/2018 21:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 29 15.25 446 197 0.20 / 32.72 2 2
2 3 1032.48 1 15.28 1772 27 0.22 / 32.75 2 2
3 7 2003.88 40 14.96 2838 1698 1.92 / 34.45 2 2
4 13 1467.72 18 15.03 2236 605 2.53 / 35.05 2 2
5 13 766.88 18 15.15 1370 374 2.90 / 35.43 2 2
6 13 238.36 18 15.26 677 186 3.09 / 35.61 2 2
7 13 66.24 18 15.30 438 121 3.21 / 35.73 2 2
8 8 0.04 165 15.28 334 842 4.05 / 36.58 2 4
Average= 3.33
(KJ/cycle)

Cycle 9 GMT 13/ 9/2018 23:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 29 15.26 459 203 0.20 / 28.82 2 2
2 7 2009.56 40 14.96 2833 1695 1.90 / 30.51 2 2
3 13 1340.52 18 15.06 2056 557 2.46 / 31.07 2 2
4 13 693.28 18 15.17 1266 346 2.80 / 31.42 2 3
5 13 201.84 18 15.27 627 172 2.97 / 31.59 2 2
6 13 59.88 18 15.30 421 116 3.09 / 31.70 2 2
7 8 0.08 165 15.28 326 822 3.91 / 32.53 2 5
Average= 3.25
(KJ/cycle)

Cycle 8 GMT 4/ 9/2018 1:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 29 15.26 457 202 0.20 / 25.29 2 2
2 7 1521.52 40 15.10 2262 1366 1.57 / 26.65 2 2
3 13 1214.40 18 15.12 1917 522 2.09 / 27.17 2 2
4 13 687.48 18 15.19 1268 347 2.44 / 27.52 2 2
5 13 169.60 18 15.30 592 163 2.60 / 27.68 2 2
6 13 47.88 18 15.32 403 111 2.71 / 27.79 2 2
7 8 0.00 165 15.29 325 820 3.53 / 28.61 2 7
Average= 3.18
(KJ/cycle)

Cycle 7 GMT 3/ 9/2018 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 29 15.26 444 196 0.20 / 21.79 2 2
2 7 1523.84 41 15.09 2257 1396 1.59 / 23.19 2 2
3 13 1216.32 18 15.12 1904 518 2.11 / 23.70 2 2
4 13 548.08 18 15.22 1083 297 2.41 / 24.00 2 2
5 13 127.08 18 15.31 517 142 2.55 / 24.14 2 2
6 13 71.68 18 15.31 435 120 2.67 / 24.26 2 2
7 8 0.12 165 15.29 325 820 3.49 / 25.08 2 5
Average= 3.14
(KJ/cycle)

Cycle 6 GMT 2/ 9/2018 0:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 29 15.26 440 195 0.19 / 18.33 2 2
2 7 1506.40 40 15.10 2241 1354 1.55 / 19.68 2 2
3 13 1190.16 18 15.12 1878 511 2.06 / 20.19 2 2
4 13 659.76 18 15.20 1221 334 2.39 / 20.53 2 2
5 13 153.56 18 15.30 560 154 2.55 / 20.68 2 2
6 13 44.48 18 15.32 393 108 2.66 / 20.79 2 2
7 8 0.00 165 15.30 318 803 3.46 / 21.59 2 3
Average= 3.08
(KJ/cycle)

Cycle 5 GMT 1/ 9/2018 0:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 29 15.27 443 196 0.20 / 14.90 2 2
2 7 1526.64 40 15.10 2252 1360 1.56 / 16.26 2 2
3 13 1081.72 18 15.14 1746 476 2.03 / 16.73 2 2
4 13 599.68 18 15.21 1150 315 2.35 / 17.05 2 2
5 13 136.40 18 15.30 536 148 2.49 / 17.20 2 2
6 13 77.04 18 15.31 444 122 2.62 / 17.32 2 2
7 8 0.04 165 15.29 323 815 3.43 / 18.13 2 4
Average= 3.02
(KJ/cycle)

Cycle 4 GMT 31/ 8/2018 0:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 28 15.26 432 185 0.18 / 11.43 2 2
2 7 1525.40 40 15.10 2250 1359 1.54 / 12.79 2 2
3 13 1217.32 18 15.12 1898 517 2.06 / 13.30 2 2
4 13 699.76 18 15.19 1264 346 2.41 / 13.65 2 2
5 13 160.12 18 15.30 559 154 2.56 / 13.80 2 2
6 13 44.24 18 15.32 389 107 2.67 / 13.91 2 2
7 8 0.04 165 15.29 314 792 3.46 / 14.70 2 6
Average= 2.94
(KJ/cycle)

Cycle 3 GMT 30/ 8/2018 0:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 28 15.26 428 183 0.18 / 7.95 2 2
2 7 1507.64 40 15.10 2226 1345 1.53 / 9.29 2 2
3 13 1352.16 18 15.10 2060 560 2.09 / 9.85 2 2
4 13 640.56 18 15.20 1184 324 2.41 / 10.18 2 2
5 13 145.80 18 15.30 538 148 2.56 / 10.33 2 2
6 13 78.64 18 15.31 438 121 2.68 / 10.45 2 2
7 8 -0.04 165 15.29 316 797 3.48 / 11.24 2 7
Average= 2.81
(KJ/cycle)

Cycle 2 GMT 29/ 8/2018 0:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 29 15.30 413 183 0.18 / 4.65 2 2
2 7 1522.36 40 15.10 2227 1345 1.53 / 5.99 2 2
3 13 1076.64 18 15.15 1707 465 1.99 / 6.46 2 2
4 13 591.16 18 15.21 1110 304 2.30 / 6.76 2 2
5 13 131.48 18 15.31 501 138 2.44 / 6.90 2 2
6 13 76.12 18 15.31 415 114 2.55 / 7.01 2 2
7 8 0.04 165 15.30 298 752 3.30 / 7.77 2 4
Average= 2.59
(KJ/cycle)

Cycle 1 GMT 27/ 8/2018 23:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 28 15.52 387 168 0.17 / 1.59 2 2
2 7 1000.96 75 15.19 1572 1791 1.96 / 3.38 2 2
3 8 -0.04 240 15.35 295 1087 3.05 / 4.46 2 9
Average= 2.23
(KJ/cycle)

Cycle 0 GMT 27/ 8/2018 13:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 99.96 22 15.65 369 127 0.13 / 0.13 2 2
2 7 117.24 74 15.61 386 446 0.57 / 0.57 2 2
3 8 0.28 240 15.58 226 845 1.42 / 1.42 2 3
Average= 1.42
(KJ/cycle)