SIO Argo Site:
Pump Diagnostics Page   



Serial= 8667 WMO= 5905690

Return

←PreviousNext→

Cycle 232 GMT 18/12/2024 2:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 37 14.81 465 255 0.25 / 901.12 2 2
2 12 1142.16 4 15.03 1862 112 0.37 / 901.23 2 2
3 7 2002.88 36 14.62 2805 1476 1.84 / 902.71 2 3
4 13 1354.56 18 14.66 2060 544 2.39 / 903.25 2 3
5 13 1020.12 18 14.66 1660 438 2.82 / 903.69 2 4
6 13 350.56 18 14.81 819 218 3.04 / 903.91 2 5
7 8 0.20 165 14.86 323 792 3.84 / 904.70 2 10
Average= 3.88
(KJ/cycle)

Cycle 231 GMT 8/12/2024 4:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 37 14.80 461 252 0.25 / 897.12 2 2
2 12 1182.28 4 15.02 1910 115 0.37 / 897.23 2 2
3 7 2007.88 36 14.62 2809 1478 1.85 / 898.71 2 3
4 13 1510.68 18 14.64 2236 589 2.43 / 899.30 2 3
5 13 1001.12 18 14.67 1631 431 2.87 / 899.73 2 3
6 13 337.72 18 14.81 787 210 3.08 / 899.94 2 4
7 8 -0.08 165 14.86 319 782 3.86 / 900.72 2 6
8 14 -0.08 30 14.83 318 141 4.00 / 900.86 2 5
Average= 3.88
(KJ/cycle)

Cycle 230 GMT 28/11/2024 6:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 37 14.81 439 241 0.24 / 893.27 2 2
2 12 1143.48 4 15.05 1871 113 0.35 / 893.38 2 2
3 7 2006.44 36 14.63 2803 1476 1.83 / 894.86 2 3
4 13 1508.44 18 14.64 2242 591 2.42 / 895.45 2 3
5 13 1005.88 18 14.67 1632 431 2.85 / 895.88 2 4
6 13 355.56 18 14.79 806 215 3.07 / 896.10 2 4
7 8 0.24 165 14.84 314 769 3.83 / 896.86 2 6
Average= 3.88
(KJ/cycle)

Cycle 229 GMT 18/11/2024 8:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 37 14.79 456 250 0.25 / 889.32 2 2
2 12 1159.36 4 15.05 1879 113 0.36 / 889.44 2 2
3 7 2007.64 36 14.62 2810 1479 1.84 / 890.92 2 2
4 13 1500.92 18 14.64 2229 587 2.43 / 891.50 2 3
5 13 986.80 18 14.67 1612 426 2.85 / 891.93 2 3
6 13 281.72 18 14.83 709 189 3.04 / 892.12 2 3
7 8 0.04 165 14.85 315 772 3.82 / 892.89 2 5
8 14 0.04 30 14.83 314 140 3.96 / 893.03 2 4
Average= 3.88
(KJ/cycle)

Cycle 228 GMT 8/11/2024 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 37 14.77 448 245 0.24 / 885.42 2 2
2 12 1186.76 4 15.05 1910 115 0.36 / 885.54 2 2
3 7 2008.96 36 14.64 2812 1482 1.84 / 887.02 2 5
4 13 1506.68 18 14.65 2238 590 2.43 / 887.61 2 2
5 13 1026.92 18 14.67 1653 436 2.87 / 888.04 2 3
6 13 530.92 18 14.74 1025 272 3.14 / 888.32 2 4
7 8 0.04 165 14.83 310 759 3.90 / 889.07 2 6
Average= 3.88
(KJ/cycle)

Cycle 227 GMT 29/10/2024 12:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 37 14.81 450 247 0.25 / 881.53 2 2
2 12 1173.04 4 15.05 1902 115 0.36 / 881.65 2 2
3 7 2009.52 36 14.63 2810 1480 1.84 / 883.13 2 3
4 13 1515.20 18 14.63 2244 591 2.43 / 883.72 2 3
5 13 1007.00 18 14.65 1632 430 2.86 / 884.15 2 3
6 13 492.04 18 14.73 980 260 3.12 / 884.41 2 3
7 8 0.04 165 14.81 314 767 3.89 / 885.18 2 7
Average= 3.88
(KJ/cycle)

Cycle 226 GMT 19/10/2024 14:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 36 14.80 451 240 0.24 / 877.51 2 2
2 12 1193.32 4 15.05 1905 115 0.35 / 877.62 2 2
3 7 2007.44 37 14.64 2805 1519 1.87 / 879.14 2 4
4 13 1657.36 18 14.64 2410 635 2.51 / 879.78 2 3
5 13 971.00 18 14.67 1586 419 2.93 / 880.20 2 3
6 13 325.40 18 14.79 755 201 3.13 / 880.40 2 3
7 8 0.16 165 14.84 308 754 3.88 / 881.15 2 7
8 14 0.16 30 14.82 306 136 4.02 / 881.29 2 6
Average= 3.88
(KJ/cycle)

Cycle 225 GMT 9/10/2024 16:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 36 14.79 464 247 0.25 / 873.66 2 2
2 12 1180.48 4 15.05 1890 114 0.36 / 873.77 2 2
3 7 2009.84 36 14.63 2816 1483 1.84 / 875.25 2 4
4 13 1497.76 18 14.65 2236 590 2.43 / 875.84 2 3
5 13 1000.00 18 14.67 1629 430 2.86 / 876.27 2 4
6 13 343.68 18 14.79 803 214 3.08 / 876.49 2 4
7 8 0.16 165 14.84 318 779 3.86 / 877.27 2 6
Average= 3.88
(KJ/cycle)

Cycle 224 GMT 29/ 9/2024 18:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 36 14.81 455 243 0.24 / 869.82 2 2
2 12 1182.92 4 15.04 1893 114 0.36 / 869.93 2 2
3 7 2004.96 36 14.63 2814 1482 1.84 / 871.41 2 4
4 13 1508.40 18 14.65 2253 594 2.43 / 872.01 2 3
5 13 1004.60 18 14.67 1634 431 2.86 / 872.44 2 3
6 13 338.08 18 14.79 782 208 3.07 / 872.64 2 3
7 8 0.24 165 14.83 313 766 3.84 / 873.41 2 5
Average= 3.88
(KJ/cycle)

Cycle 223 GMT 19/ 9/2024 20:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 36 14.78 473 252 0.25 / 865.87 2 2
2 12 1175.72 4 15.05 1896 114 0.37 / 865.98 2 2
3 7 2004.40 36 14.64 2810 1481 1.85 / 867.46 2 4
4 13 1656.20 18 14.63 2416 636 2.48 / 868.10 2 3
5 13 1106.96 18 14.66 1762 465 2.95 / 868.56 2 3
6 13 412.92 18 14.79 886 236 3.18 / 868.80 2 4
7 8 -0.16 165 14.85 315 772 3.96 / 869.57 2 7
Average= 3.88
(KJ/cycle)

Cycle 222 GMT 9/ 9/2024 22:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 36 14.81 454 242 0.24 / 861.92 2 2
2 12 1179.24 4 15.05 1929 116 0.36 / 862.04 2 2
3 7 2004.32 36 14.63 2806 1478 1.84 / 863.52 2 5
4 13 1666.76 18 14.61 2429 639 2.47 / 864.16 2 3
5 13 992.16 18 14.64 1617 426 2.90 / 864.58 2 3
6 13 477.44 18 14.73 970 257 3.16 / 864.84 2 4
7 8 0.28 165 14.81 318 777 3.94 / 865.62 2 8
Average= 3.88
(KJ/cycle)

Cycle 221 GMT 31/ 8/2024 1:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 36 14.82 450 240 0.24 / 858.01 2 2
2 12 1179.68 4 15.04 1905 115 0.35 / 858.13 2 2
3 7 2004.64 37 14.63 2806 1519 1.87 / 859.65 2 3
4 13 1502.12 18 14.65 2235 589 2.46 / 860.24 2 3
5 13 882.60 18 14.70 1483 392 2.86 / 860.63 2 3
6 13 552.08 18 14.75 1061 282 3.14 / 860.91 2 4
7 8 -0.08 165 14.85 315 772 3.91 / 861.68 2 9
Average= 3.88
(KJ/cycle)

Cycle 220 GMT 21/ 8/2024 3:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 36 14.82 462 246 0.25 / 854.21 2 2
2 12 1168.68 4 15.05 1901 114 0.36 / 854.33 2 2
3 7 2001.64 36 14.63 2797 1473 1.83 / 855.80 2 5
4 13 1482.60 18 14.65 2216 584 2.42 / 856.38 2 3
5 13 977.72 18 14.68 1597 422 2.84 / 856.81 2 3
6 13 308.04 18 14.82 746 199 3.04 / 857.01 2 4
7 8 -0.24 165 14.86 313 767 3.81 / 857.77 2 9
Average= 3.88
(KJ/cycle)

Cycle 219 GMT 11/ 8/2024 5:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 36 14.83 451 241 0.24 / 850.31 2 2
2 3 1025.56 1 14.98 1710 26 0.27 / 850.34 2 3
3 12 1169.00 4 15.04 1906 115 0.38 / 850.45 2 2
4 7 2006.32 36 14.63 2801 1475 1.86 / 851.93 2 3
5 13 1500.96 18 14.64 2240 590 2.45 / 852.52 2 4
6 13 992.48 18 14.67 1619 428 2.87 / 852.95 2 3
7 13 475.12 18 14.77 966 257 3.13 / 853.20 2 4
8 8 0.04 165 14.86 311 763 3.89 / 853.97 2 5
Average= 3.88
(KJ/cycle)

Cycle 218 GMT 1/ 8/2024 7:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 36 14.83 450 240 0.24 / 846.44 2 2
2 12 1204.88 4 15.04 1943 117 0.36 / 846.56 2 2
3 7 2006.64 36 14.63 2812 1481 1.84 / 848.04 2 4
4 13 1503.88 18 14.66 2239 591 2.43 / 848.63 2 3
5 13 1005.16 18 14.68 1640 433 2.86 / 849.06 2 4
6 13 486.52 18 14.78 973 259 3.12 / 849.32 2 4
7 8 0.20 165 14.87 306 751 3.87 / 850.07 2 5
Average= 3.88
(KJ/cycle)

Cycle 217 GMT 22/ 7/2024 9:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 36 14.82 454 242 0.24 / 842.56 2 2
2 12 1185.80 4 15.03 1933 116 0.36 / 842.68 2 2
3 7 2004.88 36 14.63 2813 1482 1.84 / 844.16 2 5
4 13 1489.04 18 14.66 2222 586 2.43 / 844.74 2 3
5 13 980.72 18 14.68 1613 426 2.85 / 845.17 2 3
6 13 473.28 18 14.78 969 258 3.11 / 845.43 2 6
7 8 0.20 165 14.87 315 773 3.88 / 846.20 2 6
Average= 3.88
(KJ/cycle)

Cycle 216 GMT 12/ 7/2024 11:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 36 14.81 465 248 0.25 / 838.73 2 2
2 12 1162.32 4 15.03 1905 115 0.36 / 838.84 2 2
3 7 2010.92 36 14.63 2822 1486 1.85 / 840.33 2 3
4 13 1500.68 18 14.65 2241 591 2.44 / 840.92 2 3
5 13 870.92 18 14.71 1479 392 2.83 / 841.31 2 3
6 13 353.24 18 14.81 819 218 3.05 / 841.53 2 4
7 8 -0.28 165 14.86 321 787 3.84 / 842.32 2 8
Average= 3.88
(KJ/cycle)

Cycle 215 GMT 2/ 7/2024 13:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 36 14.81 466 248 0.25 / 834.67 2 2
2 12 1161.88 4 15.04 1878 113 0.36 / 834.78 2 2
3 7 2009.00 37 14.62 2817 1524 1.89 / 836.30 2 3
4 13 1506.88 18 14.65 2246 592 2.48 / 836.90 2 3
5 13 975.04 18 14.69 1605 424 2.90 / 837.32 2 4
6 13 465.32 18 14.78 970 258 3.16 / 837.58 2 5
7 13 24.36 18 14.89 377 101 3.26 / 837.68 2 4
8 8 0.12 165 14.85 327 801 4.06 / 838.48 2 7
Average= 3.88
(KJ/cycle)

Cycle 214 GMT 22/ 6/2024 15:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 36 14.81 456 243 0.24 / 830.82 2 2
2 12 1157.72 4 15.03 1866 112 0.36 / 830.93 2 2
3 7 2007.20 36 14.62 2809 1478 1.83 / 832.41 2 5
4 13 1498.72 18 14.64 2226 587 2.42 / 832.99 2 3
5 13 992.40 18 14.68 1620 428 2.85 / 833.42 2 4
6 13 319.80 18 14.81 774 206 3.05 / 833.63 2 4
7 8 0.00 165 14.85 322 789 3.84 / 834.42 2 10
Average= 3.88
(KJ/cycle)

Cycle 213 GMT 12/ 6/2024 17:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 36 14.82 432 230 0.23 / 826.69 2 2
2 12 1188.60 4 15.05 1926 116 0.35 / 826.81 2 2
3 7 2007.12 36 14.63 2807 1478 1.82 / 828.29 2 4
4 13 1491.12 18 14.66 2227 588 2.41 / 828.87 2 3
5 13 979.84 18 14.69 1606 425 2.84 / 829.30 2 3
6 13 448.12 18 14.77 938 249 3.09 / 829.55 2 6
7 13 54.96 18 14.87 410 110 3.20 / 829.66 2 3
8 8 0.04 165 14.85 317 777 3.97 / 830.44 2 3
9 14 0.04 30 14.82 313 139 4.11 / 830.57 2 6
Average= 3.88
(KJ/cycle)

Cycle 212 GMT 2/ 6/2024 19:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 36 14.82 457 244 0.24 / 822.62 2 2
2 3 1023.84 1 14.97 1701 25 0.27 / 822.64 2 3
3 12 1181.20 4 15.04 1898 114 0.38 / 822.76 2 2
4 7 2002.28 36 14.63 2803 1476 1.86 / 824.23 2 4
5 13 1508.92 18 14.65 2246 592 2.45 / 824.83 2 3
6 13 1005.00 18 14.68 1633 432 2.88 / 825.26 2 3
7 13 351.12 18 14.81 811 216 3.10 / 825.47 2 3
8 13 45.20 18 14.89 385 103 3.20 / 825.58 2 3
9 8 -0.16 165 14.86 306 750 3.95 / 826.33 2 5
10 14 -0.16 30 14.83 304 135 4.09 / 826.46 2 8
Average= 3.88
(KJ/cycle)

Cycle 211 GMT 23/ 5/2024 21:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 36 14.82 439 234 0.23 / 818.60 2 2
2 12 1194.80 4 15.03 1922 116 0.35 / 818.72 2 2
3 7 2009.56 36 14.64 2818 1485 1.83 / 820.20 2 3
4 13 1513.80 18 14.66 2257 596 2.43 / 820.80 2 3
5 13 1020.92 18 14.68 1648 435 2.87 / 821.23 2 3
6 13 504.36 18 14.77 1004 267 3.13 / 821.50 2 4
7 13 63.40 18 14.88 415 111 3.24 / 821.61 2 4
8 8 0.12 165 14.85 312 764 4.01 / 822.37 2 5
Average= 3.88
(KJ/cycle)

Cycle 210 GMT 13/ 5/2024 23:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.32 35 14.82 468 243 0.24 / 814.61 2 2
2 12 1171.80 4 15.04 1906 115 0.36 / 814.72 2 2
3 7 2002.56 36 14.63 2805 1477 1.83 / 816.20 2 5
4 13 1500.80 18 14.65 2231 588 2.42 / 816.79 2 3
5 13 994.72 18 14.68 1623 429 2.85 / 817.22 2 3
6 13 477.40 18 14.78 977 260 3.11 / 817.48 2 4
7 13 56.76 18 14.88 415 111 3.22 / 817.59 2 4
8 8 0.00 165 14.85 318 779 4.00 / 818.37 2 7
Average= 3.88
(KJ/cycle)

Cycle 209 GMT 4/ 5/2024 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 35 14.82 458 238 0.24 / 810.61 2 2
2 12 1179.28 4 15.05 1921 116 0.35 / 810.73 2 2
3 7 2005.68 36 14.63 2808 1479 1.83 / 812.21 2 5
4 13 1490.64 18 14.66 2225 587 2.42 / 812.80 2 3
5 13 981.12 18 14.69 1610 426 2.84 / 813.22 2 3
6 13 463.36 18 14.78 957 255 3.10 / 813.48 2 5
7 13 56.72 18 14.88 412 110 3.21 / 813.59 2 4
8 8 0.12 165 14.86 317 777 3.99 / 814.36 2 6
Average= 3.88
(KJ/cycle)

Cycle 208 GMT 24/ 4/2024 4: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 35 14.81 465 241 0.24 / 806.44 2 2
2 12 1176.64 4 15.04 1916 115 0.36 / 806.56 2 2
3 7 2006.40 36 14.63 2815 1483 1.84 / 808.04 2 5
4 13 1514.32 18 14.65 2262 596 2.44 / 808.64 2 3
5 13 996.16 18 14.68 1633 432 2.87 / 809.07 2 4
6 13 492.24 18 14.77 1005 267 3.13 / 809.34 2 4
7 13 32.68 18 14.89 387 104 3.24 / 809.44 2 4
8 8 0.08 165 14.85 324 794 4.03 / 810.23 2 5
9 14 0.08 30 14.83 318 141 4.17 / 810.38 2 7
Average= 3.88
(KJ/cycle)

Cycle 207 GMT 14/ 4/2024 5:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 36 14.82 455 243 0.24 / 802.42 2 2
2 12 1150.68 4 15.04 1884 113 0.36 / 802.53 2 2
3 7 2005.76 37 14.63 2807 1519 1.88 / 804.05 2 4
4 13 1512.56 18 14.65 2256 595 2.47 / 804.65 2 3
5 13 1003.12 18 14.68 1634 432 2.90 / 805.08 2 3
6 13 323.60 18 14.81 788 210 3.11 / 805.29 2 4
7 13 37.84 18 14.88 396 106 3.22 / 805.40 2 4
8 8 -0.08 165 14.85 329 806 4.02 / 806.20 2 6
Average= 3.88
(KJ/cycle)

Cycle 206 GMT 4/ 4/2024 7:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 36 14.81 450 240 0.24 / 798.47 2 2
2 12 1153.56 4 15.03 1892 114 0.35 / 798.58 2 2
3 7 2006.04 36 14.63 2808 1479 1.83 / 800.06 2 3
4 13 1513.56 18 14.65 2265 597 2.43 / 800.66 2 3
5 13 990.20 18 14.68 1628 430 2.86 / 801.09 2 3
6 13 329.32 18 14.81 791 211 3.07 / 801.30 2 4
7 13 20.52 18 14.89 365 98 3.17 / 801.40 2 3
8 8 0.28 165 14.86 318 780 3.95 / 802.18 2 5
Average= 3.88
(KJ/cycle)

Cycle 205 GMT 25/ 3/2024 9:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 36 14.81 455 243 0.24 / 794.45 2 2
2 12 1149.32 4 15.05 1876 113 0.36 / 794.56 2 2
3 7 2004.60 36 14.63 2815 1483 1.84 / 796.04 2 4
4 13 1514.16 18 14.66 2252 594 2.43 / 796.64 2 3
5 13 998.88 18 14.68 1633 432 2.86 / 797.07 2 3
6 13 503.48 18 14.76 1013 269 3.13 / 797.34 2 4
7 13 62.56 18 14.87 427 114 3.25 / 797.45 2 4
8 8 0.00 165 14.85 318 779 4.03 / 798.23 2 6
Average= 3.87
(KJ/cycle)

Cycle 204 GMT 15/ 3/2024 11:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 36 14.82 436 233 0.23 / 790.48 2 2
2 12 1161.04 4 15.04 1904 115 0.35 / 790.59 2 2
3 7 2002.84 36 14.63 2799 1474 1.82 / 792.07 2 3
4 13 1487.24 18 14.66 2227 588 2.41 / 792.65 2 3
5 13 983.52 18 14.68 1610 425 2.83 / 793.08 2 3
6 13 461.88 18 14.77 957 254 3.09 / 793.33 2 4
7 13 31.96 18 14.88 377 101 3.19 / 793.43 2 4
8 8 0.08 165 14.85 314 769 3.96 / 794.20 2 5
Average= 3.87
(KJ/cycle)

Cycle 203 GMT 5/ 3/2024 13:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 36 14.82 441 235 0.24 / 786.43 2 2
2 12 1161.20 4 15.05 1891 114 0.35 / 786.55 2 2
3 7 2002.32 36 14.63 2799 1474 1.82 / 788.02 2 4
4 13 1496.24 18 14.66 2230 588 2.41 / 788.61 2 3
5 13 993.84 18 14.69 1624 429 2.84 / 789.04 2 3
6 13 483.40 18 14.77 980 261 3.10 / 789.30 2 3
7 13 59.00 18 14.87 411 110 3.21 / 789.41 2 4
8 13 19.32 18 14.88 348 93 3.30 / 789.50 2 3
9 8 0.12 165 14.85 303 742 4.05 / 790.24 2 7
Average= 3.87
(KJ/cycle)

Cycle 202 GMT 24/ 2/2024 15:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 36 14.80 443 236 0.24 / 782.52 2 2
2 12 1157.60 4 15.06 1884 113 0.35 / 782.63 2 2
3 7 2008.68 36 14.63 2805 1477 1.83 / 784.11 2 3
4 13 1511.60 18 14.65 2243 591 2.42 / 784.70 2 3
5 13 1013.48 18 14.67 1642 434 2.85 / 785.14 2 4
6 13 367.20 18 14.79 821 219 3.07 / 785.35 2 4
7 13 46.40 18 14.87 386 103 3.17 / 785.46 2 3
8 8 0.00 165 14.84 302 739 3.91 / 786.20 2 6
Average= 3.87
(KJ/cycle)

Cycle 201 GMT 14/ 2/2024 17:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 36 14.82 424 226 0.23 / 778.56 2 2
2 12 1177.04 4 15.06 1895 114 0.34 / 778.68 2 2
3 7 2006.16 36 14.64 2806 1479 1.82 / 780.16 2 3
4 13 1510.60 18 14.66 2246 593 2.41 / 780.75 2 3
5 13 1005.28 18 14.69 1624 429 2.84 / 781.18 2 3
6 13 490.12 18 14.76 977 260 3.10 / 781.44 2 4
7 13 64.84 18 14.86 403 108 3.21 / 781.55 2 3
8 8 0.40 165 14.84 301 737 3.95 / 782.28 2 5
Average= 3.87
(KJ/cycle)

Cycle 200 GMT 4/ 2/2024 19:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 36 14.81 453 242 0.24 / 774.47 2 2
2 12 1174.80 4 15.05 1899 114 0.36 / 774.59 2 2
3 7 2006.12 36 14.65 2803 1478 1.83 / 776.07 2 6
4 13 1509.24 18 14.66 2240 591 2.43 / 776.66 2 3
5 13 1003.48 18 14.69 1631 431 2.86 / 777.09 2 3
6 13 494.64 18 14.77 989 263 3.12 / 777.35 2 4
7 13 69.88 18 14.88 418 112 3.23 / 777.46 2 3
8 8 0.08 165 14.86 303 743 3.97 / 778.21 2 5
9 14 0.08 30 14.83 298 133 4.11 / 778.34 2 5
Average= 3.87
(KJ/cycle)

Cycle 199 GMT 25/ 1/2024 21:24: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 36 14.81 455 243 0.24 / 770.51 2 2
2 12 1168.12 4 15.06 1881 113 0.36 / 770.62 2 2
3 7 2003.64 36 14.64 2809 1480 1.84 / 772.10 2 3
4 13 1478.52 18 14.67 2208 583 2.42 / 772.68 2 3
5 13 976.20 18 14.70 1599 423 2.84 / 773.11 2 3
6 13 481.64 18 14.78 977 260 3.10 / 773.37 2 4
7 13 28.60 18 14.88 368 99 3.20 / 773.46 2 3
8 8 -0.12 165 14.85 313 767 3.97 / 774.23 2 8
Average= 3.87
(KJ/cycle)

Cycle 198 GMT 15/ 1/2024 23:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 36 14.80 453 241 0.24 / 766.53 2 2
2 12 1158.80 4 15.05 1884 113 0.35 / 766.64 2 2
3 7 2006.24 37 14.63 2806 1519 1.87 / 768.16 2 3
4 13 1504.12 18 14.66 2246 593 2.47 / 768.75 2 2
5 13 993.16 18 14.69 1626 430 2.90 / 769.18 2 4
6 13 337.44 18 14.81 791 211 3.11 / 769.39 2 4
7 13 32.60 18 14.88 375 100 3.21 / 769.49 2 4
8 8 0.08 165 14.85 314 769 3.98 / 770.26 2 7
Average= 3.87
(KJ/cycle)

Cycle 197 GMT 6/ 1/2024 1:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 36 14.80 441 235 0.23 / 762.60 2 2
2 12 1156.80 4 15.05 1876 113 0.35 / 762.72 2 2
3 7 2003.96 36 14.63 2811 1480 1.83 / 764.20 2 3
4 13 1501.12 18 14.66 2223 587 2.42 / 764.78 2 3
5 13 984.96 18 14.69 1612 426 2.84 / 765.21 2 3
6 13 348.88 18 14.81 806 215 3.06 / 765.43 2 4
7 13 32.48 18 14.88 369 99 3.15 / 765.52 2 3
8 8 0.28 165 14.85 311 762 3.92 / 766.29 2 7
Average= 3.87
(KJ/cycle)

Cycle 196 GMT 27/12/2023 3:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 36 14.80 439 234 0.23 / 758.68 2 2
2 12 1163.96 4 15.05 1901 114 0.35 / 758.80 2 2
3 7 2008.48 36 14.63 2811 1480 1.83 / 760.28 2 4
4 13 1494.84 18 14.66 2222 586 2.42 / 760.86 2 3
5 13 989.24 18 14.69 1613 427 2.84 / 761.29 2 4
6 13 337.28 18 14.81 793 211 3.05 / 761.50 2 4
7 13 33.48 18 14.88 373 100 3.15 / 761.60 2 3
8 8 -0.12 165 14.85 314 769 3.92 / 762.37 2 9
Average= 3.87
(KJ/cycle)

Cycle 195 GMT 17/12/2023 5:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 36 14.82 442 236 0.24 / 754.71 2 2
2 12 1165.28 4 15.06 1881 113 0.35 / 754.83 2 2
3 7 2009.76 36 14.64 2811 1482 1.83 / 756.31 2 2
4 13 1502.44 18 14.66 2232 589 2.42 / 756.90 2 3
5 13 1010.72 18 14.68 1635 432 2.85 / 757.33 2 3
6 13 483.00 18 14.76 973 259 3.11 / 757.59 2 4
7 13 55.68 18 14.86 403 108 3.22 / 757.69 2 3
8 8 0.04 165 14.84 307 752 3.97 / 758.45 2 4
Average= 3.87
(KJ/cycle)

Cycle 194 GMT 7/12/2023 7:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 36 14.80 457 243 0.24 / 750.76 2 2
2 12 1176.20 4 15.05 1912 115 0.36 / 750.87 2 2
3 7 2003.28 36 14.64 2805 1478 1.84 / 752.35 2 4
4 13 1503.96 18 14.66 2227 588 2.42 / 752.94 2 3
5 13 989.36 18 14.70 1609 426 2.85 / 753.37 2 3
6 13 467.92 18 14.78 952 253 3.10 / 753.62 2 3
7 13 59.72 18 14.88 402 108 3.21 / 753.73 2 3
8 8 0.08 165 14.85 306 750 3.96 / 754.48 2 7
Average= 3.87
(KJ/cycle)

Cycle 193 GMT 27/11/2023 9:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 36 14.81 458 244 0.24 / 746.80 2 2
2 12 1172.28 4 15.06 1887 114 0.36 / 746.91 2 2
3 7 2004.92 36 14.64 2801 1476 1.83 / 748.39 2 4
4 13 1490.88 18 14.67 2215 585 2.42 / 748.97 2 3
5 13 989.56 18 14.69 1614 427 2.85 / 749.40 2 3
6 13 479.44 18 14.78 972 259 3.10 / 749.66 2 4
7 13 24.96 18 14.88 360 96 3.20 / 749.75 2 3
8 8 -0.04 165 14.85 311 762 3.96 / 750.52 2 7
Average= 3.87
(KJ/cycle)

Cycle 192 GMT 17/11/2023 11:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 36 14.81 451 240 0.24 / 742.81 2 2
2 12 1177.08 4 15.06 1903 115 0.36 / 742.93 2 2
3 7 2009.48 36 14.64 2817 1485 1.84 / 744.41 2 3
4 13 1508.88 18 14.66 2247 593 2.43 / 745.00 2 3
5 13 999.88 18 14.69 1631 431 2.86 / 745.43 2 3
6 13 477.76 18 14.78 968 258 3.12 / 745.69 2 4
7 13 24.04 18 14.88 362 97 3.22 / 745.79 2 3
8 8 -0.04 165 14.85 312 764 3.98 / 746.55 2 5
Average= 3.87
(KJ/cycle)

Cycle 191 GMT 7/11/2023 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 36 14.80 457 243 0.24 / 738.87 2 2
2 12 1173.12 4 15.05 1908 115 0.36 / 738.98 2 2
3 7 2002.36 36 14.65 2809 1481 1.84 / 740.46 2 4
4 13 1508.48 18 14.67 2248 594 2.43 / 741.06 2 3
5 13 1015.16 18 14.69 1649 436 2.87 / 741.49 2 3
6 13 378.40 18 14.80 840 224 3.09 / 741.72 2 4
7 13 21.08 18 14.89 353 95 3.19 / 741.81 2 3
8 8 0.08 165 14.86 310 760 3.95 / 742.57 2 7
Average= 3.87
(KJ/cycle)

Cycle 190 GMT 28/10/2023 15:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 36 14.81 462 246 0.25 / 734.89 2 2
2 12 1169.48 4 15.06 1891 114 0.36 / 735.00 2 2
3 7 2003.64 36 14.64 2805 1478 1.84 / 736.48 2 3
4 13 1497.52 18 14.67 2233 590 2.43 / 737.07 2 4
5 13 1001.36 18 14.69 1625 430 2.86 / 737.50 2 3
6 13 478.00 18 14.78 973 259 3.12 / 737.76 2 4
7 13 13.84 18 14.89 347 93 3.21 / 737.85 2 3
8 8 0.08 165 14.85 314 769 3.98 / 738.62 2 6
Average= 3.87
(KJ/cycle)

Cycle 189 GMT 18/10/2023 17:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 36 14.81 454 242 0.24 / 731.04 2 2
2 12 1169.60 4 15.06 1884 113 0.36 / 731.15 2 2
3 7 2003.48 36 14.64 2808 1480 1.84 / 732.63 2 4
4 13 1495.80 18 14.66 2237 590 2.43 / 733.22 2 3
5 13 997.72 18 14.69 1633 432 2.86 / 733.65 2 3
6 13 348.84 18 14.81 805 215 3.07 / 733.87 2 3
7 8 0.04 165 14.86 317 777 3.85 / 734.64 2 6
Average= 3.87
(KJ/cycle)

Cycle 188 GMT 8/10/2023 19:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 36 14.82 453 242 0.24 / 727.26 2 2
2 12 1176.36 4 15.05 1919 116 0.36 / 727.37 2 2
3 7 2007.36 36 14.64 2814 1483 1.84 / 728.85 2 5
4 13 1351.28 18 14.68 2054 543 2.38 / 729.40 2 3
5 13 886.92 18 14.71 1491 395 2.78 / 729.79 2 4
6 13 392.56 18 14.79 861 229 3.01 / 730.02 2 4
7 8 0.08 165 14.86 315 772 3.78 / 730.79 2 6
Average= 3.87
(KJ/cycle)

Cycle 187 GMT 28/ 9/2023 21:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 36 14.81 471 251 0.25 / 723.35 2 2
2 12 1183.04 4 15.06 1916 115 0.37 / 723.46 2 2
3 7 2005.48 37 14.65 2810 1523 1.89 / 724.98 2 4
4 13 1480.24 18 14.67 2214 585 2.47 / 725.57 2 3
5 13 980.80 18 14.70 1602 424 2.90 / 725.99 2 3
6 13 469.72 18 14.78 956 254 3.15 / 726.25 2 5
7 8 0.08 165 14.86 313 767 3.92 / 727.01 2 6
Average= 3.87
(KJ/cycle)

Cycle 186 GMT 18/ 9/2023 23:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 36 14.82 461 246 0.25 / 719.47 2 2
2 12 1176.88 4 15.05 1913 115 0.36 / 719.59 2 2
3 7 2003.92 37 14.65 2807 1522 1.88 / 721.11 2 2
4 13 1376.48 18 14.68 2093 553 2.44 / 721.66 2 3
5 13 1040.08 18 14.68 1680 444 2.88 / 722.11 2 3
6 13 355.28 18 14.81 810 216 3.10 / 722.32 2 4
7 8 0.16 165 14.86 315 772 3.87 / 723.09 2 7
Average= 3.87
(KJ/cycle)

Cycle 185 GMT 9/ 9/2023 1:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 36 14.81 453 242 0.24 / 715.63 2 2
2 12 1163.36 4 15.07 1877 113 0.35 / 715.75 2 2
3 7 2002.80 36 14.65 2810 1482 1.84 / 717.23 2 4
4 13 1497.48 18 14.68 2237 591 2.43 / 717.82 2 3
5 13 992.56 18 14.70 1625 430 2.86 / 718.25 2 3
6 13 330.60 18 14.82 780 208 3.07 / 718.46 2 3
7 8 0.20 165 14.86 313 767 3.83 / 719.23 2 5
Average= 3.87
(KJ/cycle)

Cycle 184 GMT 30/ 8/2023 3:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 36 14.81 460 245 0.25 / 711.61 2 2
2 12 1162.60 4 15.06 1869 113 0.36 / 711.72 2 2
3 7 2003.48 36 14.65 2812 1483 1.84 / 713.20 2 5
4 13 1496.84 18 14.68 2239 592 2.43 / 713.79 2 3
5 13 993.12 18 14.71 1621 429 2.86 / 714.22 2 3
6 13 470.48 18 14.79 961 256 3.12 / 714.48 2 4
7 8 0.32 165 14.86 316 775 3.89 / 715.25 2 9
8 14 0.32 30 14.84 314 140 4.03 / 715.39 2 6
Average= 3.87
(KJ/cycle)

Cycle 183 GMT 20/ 8/2023 5:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 36 14.81 456 243 0.24 / 707.70 2 2
2 12 1163.48 4 15.06 1893 114 0.36 / 707.81 2 2
3 7 2005.80 36 14.65 2814 1484 1.84 / 709.30 2 4
4 13 1513.64 18 14.67 2257 596 2.44 / 709.89 2 4
5 13 1002.36 18 14.70 1638 433 2.87 / 710.33 2 3
6 13 470.08 18 14.78 964 256 3.13 / 710.58 2 4
7 8 0.16 165 14.86 317 777 3.90 / 711.36 2 6
Average= 3.87
(KJ/cycle)

Cycle 182 GMT 10/ 8/2023 7:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 36 14.81 452 241 0.24 / 703.80 2 2
2 12 1177.04 4 15.05 1911 115 0.36 / 703.91 2 2
3 7 2009.96 36 14.64 2809 1480 1.84 / 705.39 2 5
4 13 1499.60 18 14.67 2233 590 2.43 / 705.98 2 3
5 13 990.76 18 14.70 1616 428 2.85 / 706.41 2 3
6 13 472.60 18 14.78 971 258 3.11 / 706.67 2 4
7 8 0.04 165 14.86 321 787 3.90 / 707.46 2 5
Average= 3.87
(KJ/cycle)

Cycle 181 GMT 31/ 7/2023 9:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.36 36 14.82 469 250 0.25 / 699.90 2 2
2 12 1175.56 4 15.05 1903 115 0.36 / 700.01 2 2
3 7 2002.24 36 14.65 2805 1479 1.84 / 701.49 2 4
4 13 1511.20 18 14.67 2247 593 2.44 / 702.09 2 4
5 13 1007.72 18 14.70 1637 433 2.87 / 702.52 2 3
6 13 495.36 18 14.78 995 265 3.14 / 702.79 2 4
7 8 -0.04 165 14.86 315 772 3.91 / 703.56 2 6
Average= 3.87
(KJ/cycle)

Cycle 180 GMT 21/ 7/2023 11:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 36 14.82 463 247 0.25 / 695.98 2 2
2 12 1176.48 4 15.07 1898 114 0.36 / 696.10 2 2
3 7 2006.84 36 14.65 2806 1480 1.84 / 697.58 2 2
4 13 1527.08 18 14.67 2264 598 2.44 / 698.18 2 3
5 13 1018.84 18 14.70 1652 437 2.88 / 698.61 2 3
6 13 519.96 18 14.78 1019 271 3.15 / 698.88 2 3
7 8 -0.08 165 14.86 312 765 3.91 / 699.65 2 4
Average= 3.87
(KJ/cycle)

Cycle 179 GMT 11/ 7/2023 13:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 36 14.81 450 240 0.24 / 692.11 2 2
2 12 1149.96 4 15.07 1874 113 0.35 / 692.23 2 2
3 7 2009.20 36 14.64 2807 1479 1.83 / 693.71 2 4
4 13 1518.52 18 14.67 2250 594 2.43 / 694.30 2 3
5 13 1025.72 18 14.69 1667 441 2.87 / 694.74 2 3
6 13 370.88 18 14.81 835 223 3.09 / 694.96 2 3
7 8 0.04 165 14.86 316 775 3.86 / 695.74 2 6
Average= 3.87
(KJ/cycle)

Cycle 178 GMT 1/ 7/2023 15: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 36 14.82 458 244 0.24 / 688.23 2 2
2 12 1177.68 4 15.07 1916 115 0.36 / 688.35 2 2
3 7 2007.24 36 14.65 2808 1481 1.84 / 689.83 2 4
4 13 1513.40 18 14.67 2255 595 2.44 / 690.42 2 3
5 13 980.44 18 14.70 1601 424 2.86 / 690.85 2 3
6 13 464.04 18 14.78 956 254 3.11 / 691.10 2 4
7 8 0.08 165 14.85 315 772 3.89 / 691.87 2 6
Average= 3.87
(KJ/cycle)

Cycle 177 GMT 21/ 6/2023 17:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 36 14.82 451 241 0.24 / 684.33 2 2
2 12 1179.32 4 15.07 1893 114 0.35 / 684.45 2 2
3 7 2004.72 36 14.66 2805 1480 1.84 / 685.93 2 4
4 13 1490.20 18 14.69 2213 585 2.42 / 686.51 2 3
5 13 990.40 18 14.71 1617 428 2.85 / 686.94 2 3
6 13 331.84 18 14.83 770 206 3.05 / 687.15 2 3
7 13 19.16 18 14.90 340 91 3.15 / 687.24 2 3
8 8 0.08 165 14.86 305 748 3.89 / 687.99 2 7
Average= 3.87
(KJ/cycle)

Cycle 176 GMT 11/ 6/2023 19:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 36 14.81 450 240 0.24 / 680.42 2 2
2 12 1169.92 4 15.07 1895 114 0.35 / 680.53 2 2
3 7 2010.72 36 14.65 2812 1483 1.84 / 682.02 2 4
4 13 1503.16 18 14.68 2239 592 2.43 / 682.61 2 3
5 13 993.44 18 14.71 1615 428 2.86 / 683.04 2 3
6 13 329.24 18 14.83 771 206 3.06 / 683.24 2 3
7 13 15.84 18 14.90 340 91 3.15 / 683.33 2 3
8 8 0.08 165 14.86 310 760 3.91 / 684.09 2 11
Average= 3.86
(KJ/cycle)

Cycle 175 GMT 1/ 6/2023 21: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 36 14.80 451 240 0.24 / 676.50 2 2
2 12 1167.96 4 15.07 1911 115 0.36 / 676.61 2 2
3 7 2007.48 36 14.65 2811 1483 1.84 / 678.09 2 4
4 13 1500.56 18 14.67 2237 591 2.43 / 678.69 2 3
5 13 997.36 18 14.70 1625 430 2.86 / 679.12 2 4
6 13 329.64 18 14.82 773 206 3.06 / 679.32 2 3
7 13 33.32 18 14.89 371 99 3.16 / 679.42 2 3
8 8 0.04 165 14.85 310 760 3.92 / 680.18 2 8
Average= 3.86
(KJ/cycle)

Cycle 174 GMT 22/ 5/2023 23: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.80 36 14.82 463 247 0.25 / 672.51 2 2
2 3 1025.40 1 15.02 1695 25 0.27 / 672.54 2 2
3 12 1164.48 4 15.07 1902 115 0.39 / 672.65 2 2
4 7 2003.08 36 14.66 2794 1475 1.86 / 674.13 2 3
5 13 1506.72 18 14.68 2247 594 2.46 / 674.72 2 4
6 13 1002.28 18 14.71 1625 430 2.89 / 675.15 2 3
7 13 467.48 18 14.78 953 254 3.14 / 675.41 2 4
8 13 26.00 18 14.88 356 95 3.23 / 675.50 2 3
9 8 0.04 165 14.85 308 755 3.99 / 676.26 2 5
Average= 3.86
(KJ/cycle)

Cycle 173 GMT 13/ 5/2023 1:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 36 14.82 448 239 0.24 / 668.58 2 2
2 12 1193.16 4 15.08 1943 117 0.36 / 668.70 2 2
3 7 2008.28 36 14.67 2809 1483 1.84 / 670.19 2 4
4 13 1499.04 18 14.68 2238 591 2.43 / 670.78 2 2
5 13 996.24 18 14.71 1619 429 2.86 / 671.21 2 3
6 13 331.88 18 14.83 770 206 3.07 / 671.41 2 3
7 13 74.44 18 14.89 420 113 3.18 / 671.52 2 3
8 8 0.36 165 14.87 303 743 3.92 / 672.27 2 7
Average= 3.86
(KJ/cycle)

Cycle 172 GMT 3/ 5/2023 3:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 36 14.82 451 241 0.24 / 664.44 2 2
2 12 1162.72 4 15.08 1881 113 0.35 / 664.55 2 2
3 7 2010.76 36 14.66 2819 1488 1.84 / 666.04 2 5
4 13 1500.96 18 14.68 2238 591 2.43 / 666.63 2 3
5 13 1007.44 18 14.71 1640 434 2.87 / 667.06 2 3
6 13 494.16 18 14.79 996 265 3.13 / 667.33 2 4
7 13 56.44 18 14.89 408 109 3.24 / 667.44 2 3
8 8 -0.20 165 14.86 313 767 4.01 / 668.21 2 6
9 14 -0.20 30 14.83 314 140 4.15 / 668.35 2 7
Average= 3.86
(KJ/cycle)

Cycle 171 GMT 23/ 4/2023 5: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 36 14.80 456 243 0.24 / 660.47 2 2
2 12 1153.24 4 15.08 1869 113 0.36 / 660.58 2 2
3 7 2004.08 36 14.66 2805 1480 1.84 / 662.06 2 4
4 13 1485.24 18 14.69 2227 589 2.42 / 662.65 2 4
5 13 976.28 18 14.72 1604 425 2.85 / 663.07 2 3
6 13 461.20 18 14.80 958 255 3.11 / 663.33 2 5
7 13 26.84 18 14.90 364 98 3.20 / 663.43 2 3
8 8 0.28 165 14.86 314 770 3.97 / 664.20 2 7
Average= 3.86
(KJ/cycle)

Cycle 170 GMT 13/ 4/2023 7: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.96 36 14.81 458 244 0.24 / 656.46 2 2
2 12 1160.36 4 15.06 1883 113 0.36 / 656.58 2 2
3 7 2003.52 36 14.66 2803 1479 1.84 / 658.06 2 3
4 13 1510.00 18 14.68 2242 592 2.43 / 658.65 2 3
5 13 995.64 18 14.70 1628 431 2.86 / 659.08 2 3
6 13 489.04 18 14.78 989 263 3.12 / 659.34 2 3
7 13 58.80 18 14.87 414 111 3.23 / 659.45 2 3
8 8 -0.16 165 14.85 315 772 4.01 / 660.22 2 7
Average= 3.86
(KJ/cycle)

Cycle 169 GMT 3/ 4/2023 9:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 36 14.82 433 231 0.23 / 652.58 2 2
2 12 1168.96 4 15.08 1875 113 0.34 / 652.69 2 2
3 7 2003.36 36 14.66 2795 1475 1.82 / 654.17 2 5
4 13 1488.08 18 14.68 2227 588 2.41 / 654.76 2 3
5 13 984.44 18 14.71 1606 425 2.83 / 655.18 2 3
6 13 317.36 18 14.83 743 198 3.03 / 655.38 2 3
7 13 69.12 18 14.88 406 109 3.14 / 655.49 2 3
8 8 0.16 165 14.85 298 730 3.87 / 656.22 2 8
Average= 3.86
(KJ/cycle)

Cycle 168 GMT 24/ 3/2023 11:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 37 14.82 445 244 0.24 / 648.63 2 2
2 12 1172.28 4 15.09 1870 113 0.36 / 648.74 2 2
3 7 2005.68 36 14.66 2810 1483 1.84 / 650.22 2 3
4 13 1515.12 18 14.68 2250 595 2.43 / 650.82 2 3
5 13 1007.68 18 14.71 1630 432 2.87 / 651.25 2 3
6 13 496.00 18 14.79 982 261 3.13 / 651.51 2 3
7 13 74.56 18 14.89 414 111 3.24 / 651.62 2 3
8 8 0.20 165 14.86 297 728 3.97 / 652.35 2 7
Average= 3.86
(KJ/cycle)

Cycle 167 GMT 14/ 3/2023 13:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 37 14.80 426 233 0.23 / 644.70 2 2
2 12 1158.00 4 15.07 1882 113 0.35 / 644.81 2 2
3 7 2003.80 36 14.66 2801 1478 1.82 / 646.29 2 3
4 13 1506.36 18 14.68 2241 592 2.42 / 646.88 2 3
5 13 1022.60 18 14.70 1652 437 2.85 / 647.32 2 3
6 13 349.68 18 14.82 803 214 3.07 / 647.53 2 4
7 13 43.72 18 14.89 384 103 3.17 / 647.63 2 3
8 8 0.08 165 14.86 305 748 3.92 / 648.38 2 4
Average= 3.86
(KJ/cycle)

Cycle 166 GMT 4/ 3/2023 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 36 14.85 426 228 0.23 / 640.70 2 2
2 10 1008.12 2 14.97 1633 49 0.28 / 640.75 2 2
3 12 1161.72 4 15.09 1867 113 0.39 / 640.86 2 2
4 7 2008.20 36 14.67 2807 1482 1.87 / 642.35 2 3
5 13 1503.96 18 14.69 2233 590 2.46 / 642.94 2 3
6 13 1002.56 18 14.71 1627 431 2.89 / 643.37 2 3
7 13 497.16 18 14.78 988 263 3.16 / 643.63 2 3
8 13 68.92 18 14.87 401 107 3.26 / 643.74 2 3
9 8 -0.12 165 14.84 296 725 3.99 / 644.46 2 5
Average= 3.86
(KJ/cycle)

Cycle 165 GMT 22/ 2/2023 17:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 36 14.83 458 245 0.24 / 636.81 2 2
2 12 1209.20 4 15.09 1951 118 0.36 / 636.93 2 2
3 7 2008.56 36 14.68 2816 1488 1.85 / 638.42 2 4
4 13 1501.96 18 14.70 2239 592 2.44 / 639.01 2 3
5 13 1014.88 18 14.73 1642 435 2.88 / 639.44 2 3
6 13 358.00 18 14.84 793 212 3.09 / 639.66 2 3
7 13 51.48 18 14.91 377 101 3.19 / 639.76 2 3
8 8 0.44 165 14.89 292 717 3.91 / 640.47 2 6
Average= 3.86
(KJ/cycle)

Cycle 164 GMT 12/ 2/2023 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 36 14.82 458 244 0.24 / 632.81 2 2
2 12 1175.24 4 15.06 1917 115 0.36 / 632.92 2 2
3 7 2006.80 36 14.66 2814 1485 1.84 / 634.41 2 3
4 13 1494.84 18 14.69 2237 592 2.44 / 635.00 2 3
5 13 977.68 18 14.72 1604 425 2.86 / 635.42 2 3
6 13 451.60 18 14.81 942 251 3.11 / 635.67 2 4
7 13 29.32 18 14.90 379 102 3.21 / 635.78 2 3
8 8 0.36 165 14.87 322 790 4.00 / 636.57 2 7
Average= 3.86
(KJ/cycle)

Cycle 163 GMT 2/ 2/2023 21:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 36 14.82 450 240 0.24 / 628.81 2 2
2 12 1158.64 4 15.08 1897 114 0.35 / 628.93 2 2
3 7 2002.08 36 14.66 2800 1478 1.83 / 630.40 2 4
4 13 1478.84 18 14.70 2217 587 2.42 / 630.99 2 3
5 13 977.24 18 14.72 1606 426 2.84 / 631.42 2 4
6 13 458.52 18 14.80 955 254 3.10 / 631.67 2 4
7 13 27.40 18 14.90 374 100 3.20 / 631.77 2 4
8 8 -0.08 165 14.86 322 790 3.99 / 632.56 2 10
Average= 3.86
(KJ/cycle)

Cycle 162 GMT 23/ 1/2023 23:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 36 14.83 450 240 0.24 / 624.82 2 2
2 12 1169.84 4 15.07 1906 115 0.36 / 624.94 2 2
3 7 2004.16 36 14.66 2804 1480 1.83 / 626.42 2 5
4 13 1495.36 18 14.69 2241 593 2.43 / 627.01 2 3
5 13 976.56 18 14.72 1603 425 2.85 / 627.44 2 3
6 13 446.80 18 14.81 941 251 3.10 / 627.69 2 4
7 13 25.24 18 14.90 371 100 3.20 / 627.79 2 3
8 8 -0.04 165 14.86 321 787 3.99 / 628.57 2 4
Average= 3.86
(KJ/cycle)

Cycle 161 GMT 14/ 1/2023 1:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 36 14.83 462 247 0.25 / 620.81 2 2
2 12 1185.36 4 15.08 1910 115 0.36 / 620.92 2 2
3 7 2002.76 36 14.67 2802 1480 1.84 / 622.40 2 5
4 13 1486.00 18 14.70 2222 588 2.43 / 622.99 2 3
5 13 975.28 18 14.72 1601 424 2.85 / 623.42 2 3
6 13 462.32 18 14.81 956 255 3.11 / 623.67 2 4
7 8 0.24 165 14.88 315 773 3.88 / 624.44 2 4
8 14 0.24 30 14.85 313 139 4.02 / 624.58 2 7
Average= 3.86
(KJ/cycle)

Cycle 160 GMT 4/ 1/2023 3:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 36 14.84 458 245 0.24 / 616.95 2 2
2 12 1167.88 4 15.08 1908 115 0.36 / 617.06 2 2
3 7 2002.88 36 14.67 2808 1483 1.84 / 618.55 2 2
4 13 1490.68 18 14.70 2235 591 2.43 / 619.14 2 3
5 13 988.92 18 14.73 1625 431 2.86 / 619.57 2 3
6 13 322.84 18 14.84 774 207 3.07 / 619.78 2 4
7 8 0.04 165 14.87 320 785 3.86 / 620.56 2 5
Average= 3.85
(KJ/cycle)

Cycle 159 GMT 25/12/2022 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 36 14.84 469 251 0.25 / 613.08 2 2
2 12 1179.76 4 15.09 1919 116 0.37 / 613.19 2 2
3 7 2002.16 36 14.67 2810 1484 1.85 / 614.68 2 3
4 13 1507.60 18 14.70 2249 595 2.45 / 615.27 2 3
5 13 1000.32 18 14.73 1636 434 2.88 / 615.71 2 4
6 13 327.28 18 14.84 784 209 3.09 / 615.92 2 4
7 8 0.28 165 14.88 321 788 3.88 / 616.70 2 6
Average= 3.85
(KJ/cycle)

Cycle 158 GMT 15/12/2022 7:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 36 14.81 460 245 0.25 / 608.91 2 2
2 12 1145.92 4 15.08 1878 113 0.36 / 609.02 2 2
3 7 2012.32 36 14.66 2822 1489 1.85 / 610.51 2 4
4 13 1505.76 18 14.69 2240 592 2.44 / 611.10 2 3
5 13 986.72 18 14.73 1614 428 2.87 / 611.53 2 3
6 13 469.48 18 14.81 971 259 3.13 / 611.79 2 4
7 13 22.92 18 14.91 370 99 3.23 / 611.89 2 3
8 8 0.16 165 14.87 324 795 4.02 / 612.69 2 9
9 14 0.16 30 14.85 320 143 4.16 / 612.83 2 6
Average= 3.85
(KJ/cycle)

Cycle 157 GMT 5/12/2022 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 36 14.84 447 239 0.24 / 605.15 2 2
2 12 1157.40 4 15.07 1880 113 0.35 / 605.26 2 2
3 7 2005.00 36 14.66 2817 1487 1.84 / 606.75 2 4
4 13 1365.16 18 14.70 2081 551 2.39 / 607.30 2 3
5 13 883.12 18 14.73 1489 395 2.78 / 607.70 2 4
6 13 243.16 18 14.85 668 179 2.96 / 607.87 2 4
7 8 -0.04 165 14.86 322 790 3.75 / 608.66 2 6
Average= 3.85
(KJ/cycle)

Cycle 156 GMT 25/11/2022 10:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 36 14.83 449 240 0.24 / 601.07 2 2
2 12 1180.64 4 15.07 1910 115 0.35 / 601.19 2 2
3 7 2009.68 36 14.67 2812 1485 1.84 / 602.67 2 4
4 13 1516.40 18 14.69 2263 598 2.44 / 603.27 2 3
5 13 1008.24 18 14.72 1641 435 2.87 / 603.71 2 3
6 13 349.08 18 14.84 800 214 3.09 / 603.92 2 3
7 13 16.68 18 14.91 348 93 3.18 / 604.01 2 3
8 8 0.24 165 14.88 310 761 3.94 / 604.78 2 9
9 14 0.24 30 14.85 306 136 4.08 / 604.91 2 10
Average= 3.85
(KJ/cycle)

Cycle 155 GMT 15/11/2022 12:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 36 14.83 459 245 0.25 / 597.09 2 2
2 12 1178.84 4 15.08 1911 115 0.36 / 597.21 2 2
3 7 2002.28 36 14.67 2816 1487 1.85 / 598.69 2 5
4 13 1498.60 18 14.69 2227 589 2.44 / 599.28 2 3
5 13 988.84 18 14.73 1617 429 2.87 / 599.71 2 3
6 13 469.44 18 14.80 962 256 3.12 / 599.97 2 4
7 13 21.64 18 14.90 359 96 3.22 / 600.06 2 3
8 8 -0.16 165 14.87 314 770 3.99 / 600.83 2 8
Average= 3.85
(KJ/cycle)

Cycle 154 GMT 5/11/2022 14:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 36 14.84 455 243 0.24 / 593.09 2 2
2 12 1174.72 4 15.09 1912 115 0.36 / 593.21 2 2
3 7 2006.72 36 14.67 2819 1489 1.85 / 594.70 2 5
4 13 1487.24 18 14.70 2220 587 2.43 / 595.28 2 3
5 13 974.44 18 14.73 1599 424 2.86 / 595.71 2 3
6 13 444.60 18 14.82 929 248 3.11 / 595.96 2 4
7 8 0.56 165 14.88 307 754 3.86 / 596.71 2 4
8 14 0.56 30 14.86 306 136 4.00 / 596.85 2 7
Average= 3.85
(KJ/cycle)

Cycle 153 GMT 26/10/2022 16:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 36 14.83 453 242 0.24 / 589.16 2 2
2 12 1185.08 4 15.08 1938 117 0.36 / 589.28 2 2
3 7 2007.36 36 14.68 2811 1486 1.84 / 590.77 2 4
4 13 1502.40 18 14.70 2238 592 2.44 / 591.36 2 3
5 13 987.64 18 14.73 1617 429 2.87 / 591.79 2 3
6 13 329.40 18 14.85 777 208 3.07 / 592.00 2 4
7 13 30.68 18 14.91 365 98 3.17 / 592.09 2 3
8 8 -0.20 165 14.88 308 756 3.93 / 592.85 2 7
Average= 3.85
(KJ/cycle)

Cycle 152 GMT 16/10/2022 18:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 36 14.83 450 240 0.24 / 585.30 2 2
2 12 1168.00 4 15.09 1904 115 0.36 / 585.42 2 2
3 7 2005.32 37 14.67 2816 1528 1.88 / 586.95 2 4
4 13 1361.00 18 14.70 2073 549 2.43 / 587.50 2 3
5 13 1025.24 18 14.72 1658 439 2.87 / 587.94 2 3
6 13 342.32 18 14.84 797 213 3.08 / 588.15 2 3
7 8 0.04 165 14.88 315 773 3.86 / 588.92 2 5
Average= 3.85
(KJ/cycle)

Cycle 151 GMT 6/10/2022 20:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 36 14.83 469 250 0.25 / 581.27 2 2
2 12 1177.00 4 15.09 1913 115 0.37 / 581.38 2 2
3 7 2005.12 36 14.68 2815 1488 1.85 / 582.87 2 2
4 13 1500.36 18 14.70 2238 592 2.45 / 583.46 2 3
5 13 991.84 18 14.73 1624 431 2.88 / 583.89 2 3
6 13 464.76 18 14.81 962 256 3.13 / 584.15 2 4
7 8 0.20 165 14.88 316 776 3.91 / 584.92 2 8
8 14 0.20 30 14.86 314 140 4.05 / 585.06 2 6
Average= 3.85
(KJ/cycle)

Cycle 150 GMT 26/ 9/2022 22:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 35 14.84 459 238 0.24 / 577.30 2 2
2 12 1179.48 4 15.08 1927 116 0.35 / 577.42 2 2
3 7 2006.44 36 14.68 2810 1485 1.84 / 578.91 2 2
4 13 1503.68 18 14.70 2253 596 2.44 / 579.50 2 3
5 13 997.80 18 14.73 1633 433 2.87 / 579.93 2 4
6 13 333.96 18 14.85 782 209 3.08 / 580.14 2 4
7 13 31.36 18 14.91 370 99 3.18 / 580.24 2 3
8 8 0.24 165 14.88 315 773 3.95 / 581.02 2 7
Average= 3.85
(KJ/cycle)

Cycle 149 GMT 17/ 9/2022 0:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 35 14.84 475 247 0.25 / 573.26 2 2
2 12 1165.44 4 15.09 1901 115 0.36 / 573.38 2 2
3 7 2002.32 36 14.67 2808 1483 1.84 / 574.86 2 2
4 13 1496.80 18 14.70 2244 594 2.44 / 575.45 2 3
5 13 990.52 18 14.73 1620 430 2.87 / 575.88 2 3
6 13 468.48 18 14.81 965 257 3.12 / 576.14 2 3
7 8 -0.12 165 14.89 319 784 3.91 / 576.92 2 7
8 14 -0.12 30 14.86 316 141 4.05 / 577.07 2 9
Average= 3.85
(KJ/cycle)

Cycle 148 GMT 7/ 9/2022 2:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 35 14.85 462 240 0.24 / 569.30 2 2
2 12 1174.24 4 15.09 1896 114 0.35 / 569.42 2 2
3 7 2008.08 37 14.68 2812 1527 1.88 / 570.94 2 4
4 13 1502.48 18 14.70 2246 594 2.48 / 571.54 2 3
5 13 998.56 18 14.73 1629 432 2.91 / 571.97 2 3
6 13 477.32 18 14.81 978 261 3.17 / 572.23 2 4
7 8 0.04 165 14.89 320 786 3.96 / 573.02 2 7
Average= 3.85
(KJ/cycle)

Cycle 147 GMT 28/ 8/2022 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 36 14.83 459 245 0.25 / 565.46 2 2
2 3 972.04 -1 15.34 0 0 0.00 / 565.46 2 2
3 12 1163.08 4 15.09 1900 115 0.36 / 565.57 2 2
4 7 2004.56 36 14.67 2806 1482 1.84 / 567.05 2 2
5 13 1494.72 18 14.70 2238 592 2.43 / 567.65 2 3
6 13 987.12 18 14.74 1614 428 2.86 / 568.08 2 3
7 13 326.76 18 14.85 774 207 3.07 / 568.28 2 4
8 8 0.24 165 14.89 317 779 3.85 / 569.06 2 7
Average= 3.85
(KJ/cycle)

Cycle 146 GMT 18/ 8/2022 6:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 36 14.82 460 245 0.25 / 561.59 2 2
2 12 1151.32 4 15.08 1877 113 0.36 / 561.71 2 2
3 7 2003.48 36 14.67 2808 1483 1.84 / 563.19 2 3
4 13 1384.20 18 14.71 2114 560 2.40 / 563.75 2 3
5 13 1058.32 18 14.71 1701 450 2.85 / 564.20 2 4
6 13 386.88 18 14.82 860 229 3.08 / 564.43 2 3
7 8 0.00 165 14.88 320 786 3.87 / 565.21 2 6
Average= 3.84
(KJ/cycle)

Cycle 145 GMT 8/ 8/2022 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 36 14.85 440 235 0.24 / 557.68 2 2
2 3 1020.00 1 15.06 1694 26 0.26 / 557.70 2 2
3 12 1149.64 4 15.08 1872 113 0.37 / 557.82 2 2
4 7 2002.92 36 14.68 2808 1484 1.86 / 559.30 2 3
5 13 1513.68 18 14.70 2250 595 2.45 / 559.90 2 3
6 13 1008.60 18 14.72 1634 433 2.89 / 560.33 2 3
7 13 496.84 18 14.79 994 265 3.15 / 560.59 2 3
8 8 0.08 165 14.87 307 753 3.90 / 561.35 2 6
Average= 3.84
(KJ/cycle)

Cycle 144 GMT 29/ 7/2022 10:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 36 14.84 456 244 0.24 / 553.84 2 2
2 12 1184.72 4 15.10 1905 115 0.36 / 553.96 2 2
3 7 2004.40 36 14.69 2809 1486 1.84 / 555.44 2 3
4 13 1488.56 18 14.71 2222 588 2.43 / 556.03 2 3
5 13 991.24 18 14.74 1615 428 2.86 / 556.46 2 3
6 13 471.28 18 14.82 942 251 3.11 / 556.71 2 3
7 8 0.00 165 14.89 297 730 3.84 / 557.44 2 5
Average= 3.84
(KJ/cycle)

Cycle 143 GMT 19/ 7/2022 12:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 36 14.87 439 235 0.24 / 549.97 2 2
2 12 1180.44 4 15.10 1905 115 0.35 / 550.08 2 2
3 7 2002.84 36 14.69 2807 1484 1.83 / 551.57 2 4
4 13 1353.88 18 14.72 2064 547 2.38 / 552.11 2 3
5 13 1031.92 18 14.73 1662 441 2.82 / 552.55 2 3
6 13 356.64 18 14.84 801 214 3.04 / 552.77 2 3
7 13 20.16 18 14.92 336 90 3.13 / 552.86 2 3
8 8 0.16 165 14.88 302 741 3.87 / 553.60 2 9
Average= 3.84
(KJ/cycle)

Cycle 142 GMT 9/ 7/2022 14:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 36 14.91 466 250 0.25 / 546.08 2 2
2 12 1194.32 4 15.08 1936 117 0.37 / 546.20 2 2
3 7 2005.96 36 14.67 2811 1485 1.85 / 547.68 2 6
4 13 1500.68 18 14.70 2238 592 2.44 / 548.27 2 3
5 13 987.64 18 14.73 1611 427 2.87 / 548.70 2 3
6 13 333.80 18 14.86 770 206 3.08 / 548.91 2 3
7 13 46.48 18 14.93 372 100 3.18 / 549.01 2 3
8 8 0.04 165 14.90 296 728 3.90 / 549.73 2 5
Average= 3.84
(KJ/cycle)

Cycle 141 GMT 29/ 6/2022 16: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 36 14.84 459 245 0.25 / 542.71 2 2
2 12 1245.08 4 15.08 2009 121 0.37 / 542.83 2 2
3 7 1288.80 36 14.92 1965 1055 1.42 / 543.88 2 4
4 13 1185.60 18 14.90 1849 496 1.92 / 544.38 2 3
5 13 868.44 18 14.91 1459 392 2.31 / 544.77 2 4
6 13 336.64 18 14.97 781 210 2.52 / 544.98 2 3
7 13 35.72 18 15.00 361 97 2.62 / 545.08 2 3
8 8 0.04 165 14.97 303 748 3.37 / 545.83 2 7
Average= 3.84
(KJ/cycle)

Cycle 140 GMT 19/ 6/2022 16:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 36 14.89 441 236 0.24 / 538.82 2 2
2 12 1157.32 4 15.08 1878 113 0.35 / 538.93 2 2
3 7 1929.52 36 14.68 2736 1446 1.80 / 540.38 2 3
4 13 1437.72 18 14.71 2158 571 2.37 / 540.95 2 3
5 13 939.72 18 14.74 1558 413 2.78 / 541.36 2 4
6 13 418.64 18 14.83 896 239 3.02 / 541.60 2 4
7 13 56.48 18 14.91 396 106 3.13 / 541.71 2 3
8 8 0.16 165 14.88 307 754 3.88 / 542.46 2 8
Average= 3.85
(KJ/cycle)

Cycle 139 GMT 9/ 6/2022 16: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 36 14.86 442 236 0.24 / 535.37 2 2
2 12 1173.76 4 15.09 1904 115 0.35 / 535.49 2 2
3 7 1428.80 36 14.86 2137 1143 1.49 / 536.63 2 3
4 13 1292.12 18 14.85 1986 531 2.03 / 537.16 2 3
5 13 811.04 18 14.88 1396 374 2.40 / 537.53 2 3
6 13 297.68 18 14.95 731 197 2.60 / 537.73 2 3
7 13 67.52 18 14.98 411 111 2.71 / 537.84 2 3
8 8 0.32 165 14.95 301 742 3.45 / 538.58 2 7
Average= 3.85
(KJ/cycle)

Cycle 138 GMT 30/ 5/2022 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 36 14.86 423 226 0.23 / 531.47 2 2
2 12 1170.72 4 15.09 1916 116 0.34 / 531.58 2 2
3 7 2004.48 36 14.68 2818 1489 1.83 / 533.07 2 3
4 13 1375.44 18 14.72 2083 552 2.38 / 533.62 2 3
5 13 1044.60 18 14.72 1690 448 2.83 / 534.07 2 3
6 13 372.92 18 14.84 834 223 3.05 / 534.29 2 3
7 13 52.36 18 14.92 388 104 3.16 / 534.40 2 3
8 8 -0.36 165 14.90 299 735 3.89 / 535.13 2 13
Average= 3.85
(KJ/cycle)

Cycle 137 GMT 20/ 5/2022 18:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 35 14.86 431 224 0.22 / 527.53 2 2
2 12 1166.68 4 15.09 1912 115 0.34 / 527.64 2 2
3 7 2006.88 36 14.67 2819 1489 1.83 / 529.13 2 3
4 13 1483.48 18 14.70 2221 588 2.42 / 529.72 2 3
5 13 979.36 18 14.74 1610 427 2.84 / 530.15 2 4
6 13 453.92 18 14.83 942 251 3.09 / 530.40 2 3
7 13 69.04 18 14.91 409 110 3.20 / 530.51 2 3
8 8 0.08 165 14.89 299 735 3.94 / 531.24 2 4
Average= 3.85
(KJ/cycle)

Cycle 136 GMT 10/ 5/2022 20: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 35 14.87 420 219 0.22 / 523.60 2 2
2 12 1183.36 4 15.10 1917 116 0.33 / 523.71 2 2
3 7 2001.40 36 14.68 2810 1485 1.82 / 525.20 2 5
4 13 1475.28 18 14.72 2209 585 2.40 / 525.78 2 3
5 13 973.80 18 14.75 1600 425 2.83 / 526.21 2 3
6 13 458.60 18 14.83 940 251 3.08 / 526.46 2 3
7 13 76.28 18 14.92 415 111 3.19 / 526.57 2 3
8 8 0.16 165 14.90 298 733 3.92 / 527.30 2 6
Average= 3.85
(KJ/cycle)

Cycle 135 GMT 30/ 4/2022 22:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 35 14.87 454 236 0.24 / 519.73 2 2
2 12 1168.64 4 15.10 1909 115 0.35 / 519.84 2 2
3 7 1913.12 37 14.69 2714 1475 1.83 / 521.32 2 3
4 13 1416.84 18 14.73 2138 567 2.39 / 521.88 2 3
5 13 922.60 18 14.77 1532 407 2.80 / 522.29 2 3
6 13 415.68 18 14.85 892 238 3.04 / 522.53 2 4
7 13 60.04 18 14.92 399 107 3.15 / 522.64 2 3
8 8 0.08 165 14.90 301 740 3.89 / 523.38 2 5
Average= 3.85
(KJ/cycle)

Cycle 134 GMT 20/ 4/2022 21:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 35 14.92 420 219 0.22 / 515.78 2 2
2 12 1186.28 4 15.08 1915 116 0.33 / 515.90 2 2
3 7 2002.68 36 14.67 2808 1483 1.82 / 517.38 2 4
4 13 1506.84 18 14.69 2244 593 2.41 / 517.97 2 3
5 13 983.20 18 14.73 1611 427 2.84 / 518.40 2 3
6 13 456.36 18 14.82 945 252 3.09 / 518.65 2 5
7 13 61.00 18 14.92 399 107 3.20 / 518.76 2 3
8 8 0.08 165 14.90 298 733 3.93 / 519.49 2 7
Average= 3.85
(KJ/cycle)

Cycle 133 GMT 10/ 4/2022 23:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 35 14.90 420 219 0.22 / 512.48 2 2
2 12 1166.88 4 15.09 1914 116 0.33 / 512.59 2 2
3 7 1214.52 36 14.96 1870 1007 1.34 / 513.60 2 3
4 13 1118.92 18 14.94 1772 477 1.82 / 514.08 2 3
5 13 805.52 18 14.94 1390 374 2.19 / 514.45 2 4
6 13 183.04 18 15.01 568 153 2.35 / 514.60 2 3
7 13 54.24 18 15.02 382 103 2.45 / 514.71 2 3
8 8 0.04 165 14.99 293 725 3.17 / 515.43 2 6
9 14 0.04 30 14.96 288 129 3.30 / 515.56 2 7
Average= 3.85
(KJ/cycle)

Cycle 132 GMT 1/ 4/2022 0: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 35 14.89 422 220 0.22 / 508.41 2 2
2 12 1171.52 4 15.08 1901 115 0.33 / 508.53 2 2
3 7 2005.68 36 14.68 2814 1487 1.82 / 510.02 2 4
4 13 1357.04 18 14.73 2069 549 2.37 / 510.56 2 3
5 13 883.16 18 14.76 1491 396 2.77 / 510.96 2 3
6 13 380.20 18 14.85 850 227 2.99 / 511.19 2 4
7 13 63.80 18 14.93 401 108 3.10 / 511.30 2 3
8 13 38.48 18 14.93 362 97 3.20 / 511.39 2 3
9 8 0.04 165 14.91 298 733 3.93 / 512.13 2 5
10 14 0.04 30 14.88 295 132 4.06 / 512.26 2 8
Average= 3.85
(KJ/cycle)

Cycle 131 GMT 22/ 3/2022 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 35 14.90 442 231 0.23 / 504.88 2 2
2 12 1177.16 4 15.10 1922 116 0.35 / 505.00 2 2
3 7 1560.72 36 14.82 2300 1227 1.57 / 506.23 2 3
4 13 1271.28 18 14.83 1966 525 2.10 / 506.75 2 3
5 13 796.12 18 14.85 1386 370 2.47 / 507.12 2 3
6 13 296.32 18 14.92 744 200 2.67 / 507.32 2 3
7 13 55.48 18 14.96 406 109 2.78 / 507.43 2 3
8 8 0.00 165 14.93 310 764 3.54 / 508.19 2 8
Average= 3.85
(KJ/cycle)

Cycle 130 GMT 12/ 3/2022 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 35 14.88 426 222 0.22 / 501.17 2 2
2 12 1187.84 4 15.09 1942 117 0.34 / 501.28 2 2
3 7 1648.36 36 14.79 2400 1278 1.62 / 502.56 2 2
4 13 1347.44 18 14.81 2051 547 2.16 / 503.11 2 3
5 13 853.04 18 14.83 1455 388 2.55 / 503.50 2 4
6 13 343.12 18 14.91 795 213 2.77 / 503.71 2 3
7 13 48.96 18 14.96 389 105 2.87 / 503.81 2 3
8 13 29.76 18 14.96 358 96 2.97 / 503.91 2 3
9 8 0.20 165 14.93 301 741 3.71 / 504.65 2 7
Average= 3.85
(KJ/cycle)

Cycle 129 GMT 2/ 3/2022 1:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 35 14.88 422 220 0.22 / 497.34 2 2
2 12 1171.32 4 15.09 1904 115 0.33 / 497.46 2 2
3 7 1749.08 36 14.76 2520 1339 1.67 / 498.80 2 4
4 13 1442.72 18 14.77 2173 578 2.25 / 499.37 2 3
5 13 930.60 18 14.80 1553 414 2.67 / 499.79 2 4
6 13 269.16 18 14.91 707 190 2.85 / 499.98 2 3
7 13 62.92 18 14.94 417 112 2.97 / 500.09 2 3
8 13 35.00 18 14.94 371 100 3.07 / 500.19 2 3
9 8 -0.08 165 14.91 307 755 3.82 / 500.94 2 6
Average= 3.85
(KJ/cycle)

Cycle 128 GMT 20/ 2/2022 1:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 35 14.89 408 213 0.21 / 493.47 2 2
2 12 1165.68 4 15.10 1917 116 0.33 / 493.58 2 2
3 7 2001.96 37 14.68 2802 1522 1.85 / 495.10 2 6
4 13 1341.20 18 14.73 2054 545 2.39 / 495.65 2 3
5 13 874.56 18 14.77 1478 393 2.79 / 496.04 2 3
6 13 376.92 18 14.85 841 225 3.01 / 496.27 2 4
7 13 94.72 18 14.92 449 121 3.13 / 496.39 2 3
8 8 0.08 165 14.91 299 736 3.87 / 497.12 2 6
Average= 3.85
(KJ/cycle)

Cycle 127 GMT 10/ 2/2022 2:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 35 14.89 418 218 0.22 / 489.52 2 2
2 12 1182.16 4 15.08 1937 117 0.33 / 489.64 2 2
3 7 2005.00 36 14.68 2808 1484 1.82 / 491.12 2 3
4 13 1490.64 18 14.72 2223 589 2.41 / 491.71 2 3
5 13 977.28 18 14.75 1600 425 2.83 / 492.13 2 3
6 13 316.64 18 14.88 753 202 3.03 / 492.33 2 3
7 13 84.84 18 14.93 424 114 3.15 / 492.45 2 3
8 13 21.04 18 14.94 330 89 3.24 / 492.54 2 3
9 8 0.16 165 14.92 291 716 3.95 / 493.25 2 6
Average= 3.85
(KJ/cycle)

Cycle 126 GMT 31/ 1/2022 4:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 35 14.90 417 217 0.22 / 485.46 2 2
2 12 1172.52 4 15.09 1913 115 0.33 / 485.57 2 2
3 7 2002.28 37 14.69 2802 1523 1.86 / 487.09 2 3
4 13 1477.28 18 14.72 2215 587 2.44 / 487.68 2 3
5 13 973.56 18 14.76 1604 426 2.87 / 488.11 2 4
6 13 452.16 18 14.84 943 252 3.12 / 488.36 2 4
7 13 92.04 18 14.93 439 118 3.24 / 488.48 2 3
8 13 49.04 18 14.94 375 101 3.34 / 488.58 2 3
9 8 0.00 165 14.91 294 723 4.06 / 489.30 2 5
Average= 3.85
(KJ/cycle)

Cycle 125 GMT 21/ 1/2022 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 35 14.88 427 222 0.22 / 481.28 2 2
2 12 1164.76 4 15.09 1906 115 0.34 / 481.40 2 2
3 7 2004.12 36 14.69 2806 1484 1.82 / 482.88 2 3
4 13 1489.44 18 14.72 2222 589 2.41 / 483.47 2 3
5 13 978.44 18 14.76 1607 427 2.84 / 483.90 2 4
6 13 453.12 18 14.84 950 254 3.09 / 484.15 2 4
7 13 72.52 18 14.93 424 114 3.20 / 484.26 2 3
8 13 41.44 18 14.94 375 101 3.31 / 484.36 2 3
9 8 0.84 165 14.91 301 741 4.05 / 485.10 2 6
10 14 0.84 30 14.89 297 133 4.18 / 485.24 2 12
Average= 3.85
(KJ/cycle)

Cycle 124 GMT 11/ 1/2022 8:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 35 14.89 445 232 0.23 / 477.23 2 2
2 12 1154.80 4 15.11 1887 114 0.35 / 477.35 2 2
3 7 2002.20 36 14.69 2808 1485 1.83 / 478.83 2 6
4 13 1484.28 18 14.72 2224 589 2.42 / 479.42 2 3
5 13 970.16 18 14.76 1603 426 2.85 / 479.85 2 4
6 13 442.64 18 14.85 935 250 3.10 / 480.10 2 5
7 13 74.64 18 14.94 426 115 3.21 / 480.21 2 3
8 13 43.12 18 14.94 376 101 3.31 / 480.31 2 3
9 8 0.08 165 14.91 303 745 4.06 / 481.06 2 14
Average= 3.85
(KJ/cycle)

Cycle 123 GMT 1/ 1/2022 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 35 14.89 423 220 0.22 / 473.27 2 2
2 12 1149.12 4 15.10 1872 113 0.33 / 473.38 2 2
3 7 2002.52 36 14.69 2812 1487 1.82 / 474.87 2 4
4 13 1361.20 18 14.73 2081 552 2.37 / 475.42 2 3
5 13 870.88 18 14.77 1475 392 2.76 / 475.81 2 4
6 13 384.00 18 14.86 855 229 2.99 / 476.04 2 3
7 13 61.88 18 14.94 408 110 3.10 / 476.15 2 3
8 13 34.56 18 14.94 366 98 3.20 / 476.25 2 3
9 8 0.04 165 14.91 305 750 3.95 / 477.00 2 6
Average= 3.85
(KJ/cycle)

Cycle 122 GMT 22/12/2021 11:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.24 35 14.89 439 229 0.23 / 469.34 2 2
2 12 1160.48 4 15.10 1887 114 0.34 / 469.45 2 2
3 7 2005.52 36 14.68 2807 1483 1.83 / 470.93 2 2
4 13 1497.32 18 14.72 2228 590 2.42 / 471.52 2 3
5 13 975.60 18 14.75 1606 426 2.84 / 471.95 2 3
6 13 447.96 18 14.84 935 250 3.09 / 472.20 2 4
7 13 62.44 18 14.94 401 108 3.20 / 472.31 2 3
8 8 0.04 165 14.92 301 741 3.94 / 473.05 2 7
Average= 3.85
(KJ/cycle)

Cycle 121 GMT 12/12/2021 13:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 35 14.89 412 215 0.21 / 465.31 2 2
2 12 1159.72 4 15.10 1886 114 0.33 / 465.42 2 2
3 7 2002.32 36 14.69 2806 1484 1.81 / 466.91 2 2
4 13 1502.96 18 14.72 2245 595 2.41 / 467.50 2 3
5 13 992.88 18 14.75 1615 429 2.84 / 467.93 2 3
6 13 476.76 18 14.84 966 258 3.09 / 468.19 2 3
7 13 79.56 18 14.94 416 112 3.21 / 468.30 2 3
8 13 25.56 18 14.95 339 91 3.30 / 468.39 2 3
9 8 0.04 165 14.92 291 716 4.01 / 469.11 2 4
Average= 3.85
(KJ/cycle)

Cycle 120 GMT 2/12/2021 15:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.12 35 14.90 450 235 0.23 / 461.26 2 2
2 12 1168.96 4 15.09 1903 115 0.35 / 461.38 2 2
3 7 2004.68 37 14.69 2814 1529 1.88 / 462.91 2 4
4 13 1499.08 18 14.72 2235 592 2.47 / 463.50 2 3
5 13 982.16 18 14.75 1610 427 2.90 / 463.93 2 4
6 13 463.68 18 14.85 949 254 3.15 / 464.18 2 3
7 13 75.80 18 14.94 410 110 3.26 / 464.29 2 2
8 13 20.72 18 14.95 328 88 3.35 / 464.38 2 3
9 8 0.00 165 14.92 290 714 4.06 / 465.09 2 7
Average= 3.84
(KJ/cycle)

Cycle 119 GMT 22/11/2021 17:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.88 35 14.90 447 233 0.23 / 457.37 2 2
2 12 1182.80 4 15.10 1918 116 0.35 / 457.49 2 2
3 7 2004.20 36 14.69 2810 1486 1.83 / 458.98 2 3
4 13 1494.40 18 14.73 2225 590 2.42 / 459.57 2 3
5 13 983.48 18 14.76 1611 428 2.85 / 459.99 2 3
6 13 336.04 18 14.89 766 205 3.06 / 460.20 2 3
7 13 86.60 18 14.95 421 113 3.17 / 460.31 2 3
8 8 0.16 165 14.94 291 717 3.89 / 461.03 2 7
Average= 3.84
(KJ/cycle)

Cycle 118 GMT 12/11/2021 19:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 35 14.91 443 231 0.23 / 453.48 2 2
2 12 1163.24 4 15.11 1898 115 0.35 / 453.59 2 2
3 7 2003.04 36 14.70 2809 1487 1.83 / 455.08 2 3
4 13 1494.76 18 14.73 2227 590 2.42 / 455.67 2 3
5 13 984.44 18 14.76 1612 428 2.85 / 456.10 2 4
6 13 330.56 18 14.89 766 205 3.06 / 456.30 2 3
7 13 75.68 18 14.95 413 111 3.17 / 456.41 2 3
8 8 0.00 165 14.93 296 729 3.90 / 457.14 2 4
Average= 3.84
(KJ/cycle)

Cycle 117 GMT 2/11/2021 21:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 35 14.90 450 235 0.23 / 449.55 2 2
2 12 1184.56 4 15.10 1925 116 0.35 / 449.67 2 2
3 7 2002.60 37 14.70 2809 1528 1.88 / 451.20 2 5
4 13 1477.60 18 14.73 2208 585 2.46 / 451.78 2 4
5 13 970.80 18 14.77 1598 425 2.89 / 452.21 2 4
6 13 314.04 18 14.90 749 201 3.09 / 452.41 2 3
7 13 39.16 18 14.96 367 99 3.19 / 452.51 2 3
8 8 0.16 165 14.94 299 737 3.93 / 453.24 2 5
Average= 3.84
(KJ/cycle)

Cycle 116 GMT 23/10/2021 23: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 35 14.91 430 224 0.22 / 445.60 2 2
2 12 1178.24 4 15.10 1921 116 0.34 / 445.72 2 2
3 7 2003.84 36 14.70 2810 1487 1.83 / 447.21 2 4
4 13 1487.72 18 14.73 2220 589 2.42 / 447.80 2 3
5 13 967.76 18 14.77 1595 424 2.84 / 448.22 2 3
6 13 451.52 18 14.86 936 250 3.09 / 448.47 2 4
7 13 62.00 18 14.95 399 107 3.20 / 448.58 2 3
8 8 0.16 165 14.93 301 741 3.94 / 449.32 2 5
Average= 3.84
(KJ/cycle)

Cycle 115 GMT 14/10/2021 1: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.16 35 14.90 453 236 0.24 / 441.72 2 2
2 12 1171.64 4 15.10 1926 116 0.35 / 441.83 2 2
3 7 2001.84 36 14.70 2815 1490 1.84 / 443.32 2 3
4 13 1491.20 18 14.73 2220 589 2.43 / 443.91 2 3
5 13 971.48 18 14.77 1598 425 2.86 / 444.34 2 4
6 13 323.96 18 14.90 757 203 3.06 / 444.54 2 3
7 13 82.44 18 14.95 418 112 3.17 / 444.65 2 3
8 8 0.16 165 14.94 295 727 3.90 / 445.38 2 4
Average= 3.84
(KJ/cycle)

Cycle 114 GMT 4/10/2021 2:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.12 35 14.91 450 235 0.23 / 437.75 2 2
2 12 1171.48 4 15.10 1897 115 0.35 / 437.86 2 2
3 7 2003.16 36 14.70 2813 1489 1.84 / 439.35 2 4
4 13 1505.28 18 14.72 2238 593 2.43 / 439.94 2 3
5 13 997.76 18 14.76 1628 433 2.86 / 440.38 2 3
6 13 470.76 18 14.86 963 258 3.12 / 440.63 2 5
7 13 75.72 18 14.96 415 112 3.23 / 440.75 2 3
8 8 -0.04 165 14.94 298 735 3.97 / 441.48 2 6
Average= 3.84
(KJ/cycle)

Cycle 113 GMT 24/ 9/2021 4:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 35 14.91 431 225 0.22 / 433.89 2 2
2 12 1178.32 4 15.10 1900 115 0.34 / 434.01 2 2
3 7 2001.76 36 14.70 2807 1485 1.83 / 435.49 2 6
4 13 1353.84 18 14.74 2066 548 2.37 / 436.04 2 3
5 13 884.24 18 14.78 1501 399 2.77 / 436.44 2 3
6 13 385.84 18 14.88 852 228 3.00 / 436.67 2 4
7 13 53.56 18 14.96 388 104 3.11 / 436.77 2 3
8 8 0.08 165 14.94 301 742 3.85 / 437.51 2 4
Average= 3.84
(KJ/cycle)

Cycle 112 GMT 14/ 9/2021 6:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 34 14.91 445 226 0.23 / 429.96 2 2
2 12 1185.00 4 15.10 1924 116 0.34 / 430.07 2 2
3 7 2004.16 36 14.70 2806 1485 1.83 / 431.56 2 3
4 13 1486.72 18 14.73 2225 590 2.42 / 432.15 2 3
5 13 964.08 18 14.77 1596 424 2.84 / 432.57 2 3
6 13 442.80 18 14.87 931 249 3.09 / 432.82 2 4
7 13 75.44 18 14.96 413 111 3.20 / 432.93 2 3
8 8 0.00 165 14.95 298 735 3.94 / 433.67 2 7
Average= 3.84
(KJ/cycle)

Cycle 111 GMT 4/ 9/2021 8:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 34 14.93 463 235 0.24 / 426.05 2 2
2 12 1184.60 4 15.09 1913 115 0.35 / 426.17 2 2
3 7 1861.28 36 14.72 2653 1406 1.76 / 427.57 2 3
4 13 1375.00 18 14.77 2090 556 2.31 / 428.13 2 3
5 13 887.32 18 14.80 1501 400 2.71 / 428.53 2 3
6 13 375.24 18 14.90 840 225 2.94 / 428.75 2 4
7 13 30.36 18 14.98 354 95 3.03 / 428.85 2 3
8 8 0.12 165 14.95 303 747 3.78 / 429.60 2 6
9 14 0.12 30 14.92 298 133 3.91 / 429.73 2 7
Average= 3.84
(KJ/cycle)

Cycle 110 GMT 25/ 8/2021 8: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 34 14.97 429 218 0.22 / 422.53 2 2
2 12 1172.36 4 15.08 1902 115 0.33 / 422.64 2 2
3 7 1508.80 36 14.84 2231 1192 1.52 / 423.84 2 3
4 13 1391.12 18 14.82 2105 562 2.09 / 424.40 2 3
5 13 886.64 18 14.86 1498 401 2.49 / 424.80 2 3
6 13 229.36 18 14.97 640 172 2.66 / 424.97 2 3
7 13 24.88 18 15.01 348 94 2.75 / 425.06 2 3
8 8 -0.08 165 14.98 304 751 3.51 / 425.82 2 8
Average= 3.84
(KJ/cycle)

Cycle 109 GMT 15/ 8/2021 8:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 34 14.95 452 230 0.23 / 419.46 2 2
2 12 1160.72 4 15.09 1911 115 0.35 / 419.57 2 2
3 7 1161.60 36 14.98 1807 974 1.32 / 420.55 2 3
4 13 1061.76 18 14.96 1706 459 1.78 / 421.01 2 4
5 13 767.28 18 14.95 1347 362 2.14 / 421.37 2 3
6 13 252.36 18 15.02 670 181 2.32 / 421.55 2 3
7 8 0.16 165 15.03 306 759 3.08 / 422.31 2 5
Average= 3.84
(KJ/cycle)

Cycle 108 GMT 5/ 8/2021 8:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 34 14.95 432 220 0.22 / 416.13 2 2
2 12 1165.32 4 15.09 1918 116 0.34 / 416.24 2 2
3 7 1284.52 36 14.93 1960 1053 1.39 / 417.30 2 3
4 13 1164.20 18 14.92 1829 491 1.88 / 417.79 2 3
5 13 849.16 18 14.92 1452 390 2.27 / 418.18 2 4
6 13 331.32 18 14.99 779 210 2.48 / 418.39 2 3
7 13 35.72 18 15.04 363 98 2.58 / 418.49 2 3
8 8 0.08 165 15.00 300 742 3.32 / 419.23 2 4
Average= 3.85
(KJ/cycle)

Cycle 107 GMT 26/ 7/2021 9:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 34 14.96 422 215 0.21 / 412.85 2 2
2 12 1165.96 4 15.10 1911 115 0.33 / 412.97 2 2
3 7 1296.36 36 14.93 1972 1060 1.39 / 414.03 2 3
4 13 1168.16 18 14.92 1830 491 1.88 / 414.52 2 3
5 13 854.92 18 14.92 1449 389 2.27 / 414.91 2 3
6 13 213.80 18 15.01 608 164 2.43 / 415.07 2 3
7 13 61.36 18 15.03 389 105 2.54 / 415.18 2 3
8 8 0.08 165 15.00 296 733 3.27 / 415.91 2 6
Average= 3.85
(KJ/cycle)

Cycle 106 GMT 16/ 7/2021 10: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 35 14.96 427 224 0.22 / 409.62 2 2
2 12 1149.56 4 15.09 1875 113 0.34 / 409.74 2 2
3 7 1228.92 36 14.96 1882 1014 1.35 / 410.75 2 3
4 13 1119.92 18 14.94 1766 475 1.83 / 411.23 2 3
5 13 805.28 18 14.94 1389 374 2.20 / 411.60 2 3
6 13 291.32 18 15.01 721 195 2.39 / 411.79 2 3
7 13 65.72 18 15.04 402 109 2.50 / 411.90 2 3
8 8 -0.04 165 15.02 296 734 3.24 / 412.64 2 8
Average= 3.86
(KJ/cycle)

Cycle 105 GMT 6/ 7/2021 10:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 35 14.95 429 224 0.22 / 406.31 2 2
2 12 1158.28 4 15.10 1903 115 0.34 / 406.43 2 2
3 7 1262.80 36 14.95 1936 1042 1.38 / 407.47 2 3
4 13 1157.24 18 14.93 1821 489 1.87 / 407.96 2 3
5 13 841.96 18 14.93 1437 386 2.26 / 408.35 2 3
6 13 313.12 18 15.00 755 204 2.46 / 408.55 2 3
7 13 70.56 18 15.04 410 111 2.57 / 408.66 2 3
8 8 0.12 165 15.01 298 738 3.31 / 409.40 2 4
Average= 3.86
(KJ/cycle)

Cycle 104 GMT 26/ 6/2021 11:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 35 14.92 434 227 0.23 / 402.88 2 2
2 12 1179.08 4 15.11 1910 115 0.34 / 403.00 2 2
3 7 1405.16 36 14.90 2096 1124 1.47 / 404.12 2 2
4 13 1279.64 18 14.89 1970 528 1.99 / 404.65 2 3
5 13 939.96 18 14.89 1554 417 2.41 / 405.06 2 3
6 13 251.68 18 15.00 664 179 2.59 / 405.24 2 3
7 13 60.96 18 15.03 395 107 2.70 / 405.35 2 3
8 8 0.16 165 15.00 299 740 3.44 / 406.09 2 5
Average= 3.87
(KJ/cycle)

Cycle 103 GMT 16/ 6/2021 11:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 35 14.92 433 226 0.23 / 399.22 2 2
2 12 1160.64 4 15.11 1888 114 0.34 / 399.33 2 2
3 7 1677.76 36 14.81 2425 1293 1.63 / 400.62 2 3
4 13 1365.36 18 14.82 2074 553 2.19 / 401.18 2 3
5 13 867.56 18 14.85 1472 393 2.58 / 401.57 2 3
6 13 353.04 18 14.93 809 217 2.80 / 401.79 2 4
7 13 78.48 18 14.99 428 115 2.91 / 401.90 2 3
8 8 0.00 165 14.96 304 750 3.66 / 402.65 2 6
Average= 3.87
(KJ/cycle)

Cycle 102 GMT 6/ 6/2021 11:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 35 14.92 432 226 0.23 / 395.33 2 2
2 12 1166.40 4 15.12 1895 115 0.34 / 395.45 2 2
3 7 2005.64 36 14.70 2810 1487 1.83 / 396.93 2 6
4 13 1486.96 18 14.74 2221 589 2.42 / 397.52 2 3
5 13 978.00 18 14.78 1601 426 2.84 / 397.95 2 3
6 13 311.88 18 14.91 745 200 3.04 / 398.15 2 3
7 13 77.60 18 14.97 415 112 3.15 / 398.26 2 3
8 8 0.24 165 14.96 295 728 3.88 / 398.99 2 5
Average= 3.87
(KJ/cycle)

Cycle 101 GMT 27/ 5/2021 13:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 35 14.92 422 220 0.22 / 391.46 2 2
2 12 1175.52 4 15.12 1907 115 0.34 / 391.57 2 2
3 7 2007.08 36 14.71 2809 1488 1.82 / 393.06 2 5
4 13 1487.80 18 14.74 2227 591 2.41 / 393.65 2 3
5 13 833.84 18 14.81 1429 381 2.80 / 394.03 2 3
6 13 352.08 18 14.90 801 215 3.01 / 394.25 2 4
7 13 87.68 18 14.96 434 117 3.13 / 394.36 2 3
8 8 0.08 165 14.95 302 745 3.87 / 395.11 2 8
Average= 3.87
(KJ/cycle)

Cycle 100 GMT 17/ 5/2021 15:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 35 14.91 452 236 0.24 / 387.58 2 2
2 12 1175.36 4 15.11 1910 115 0.35 / 387.69 2 2
3 7 2005.44 37 14.71 2815 1532 1.88 / 389.22 2 4
4 13 1357.72 18 14.76 2071 550 2.43 / 389.77 2 3
5 13 878.40 18 14.80 1481 395 2.83 / 390.17 2 3
6 13 381.16 18 14.89 843 226 3.05 / 390.39 2 4
7 13 65.80 18 14.98 403 109 3.16 / 390.50 2 3
8 8 0.20 165 14.96 297 733 3.90 / 391.24 2 4
Average= 3.87
(KJ/cycle)

Cycle 99 GMT 7/ 5/2021 16:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 35 14.92 431 225 0.23 / 383.65 2 2
2 12 1173.68 4 15.11 1920 116 0.34 / 383.77 2 2
3 7 2002.36 37 14.70 2810 1528 1.87 / 385.30 2 3
4 13 1359.08 18 14.76 2068 549 2.42 / 385.85 2 3
5 13 881.16 18 14.79 1491 397 2.82 / 386.25 2 4
6 13 379.64 18 14.89 842 226 3.04 / 386.47 2 3
7 13 96.56 18 14.96 450 121 3.16 / 386.59 2 3
8 8 0.08 165 14.95 303 747 3.91 / 387.34 2 7
Average= 3.87
(KJ/cycle)

Cycle 98 GMT 27/ 4/2021 18:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.52 35 14.92 448 234 0.23 / 379.71 2 2
2 12 1155.32 4 15.12 1882 114 0.35 / 379.82 2 2
3 7 2006.92 36 14.71 2810 1488 1.84 / 381.31 2 2
4 13 1492.04 18 14.75 2230 592 2.43 / 381.90 2 3
5 13 966.20 18 14.78 1592 424 2.85 / 382.33 2 4
6 13 453.64 18 14.88 943 253 3.10 / 382.58 2 4
7 13 74.48 18 14.97 419 113 3.22 / 382.69 2 3
8 8 0.20 165 14.96 299 738 3.95 / 383.43 2 10
Average= 3.87
(KJ/cycle)

Cycle 97 GMT 17/ 4/2021 20:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 35 14.93 411 215 0.21 / 375.81 2 2
2 12 1171.20 4 15.12 1912 116 0.33 / 375.92 2 2
3 7 2003.20 36 14.72 2805 1486 1.82 / 377.41 2 4
4 13 1482.16 18 14.75 2214 588 2.40 / 378.00 2 3
5 13 963.56 18 14.79 1591 424 2.83 / 378.42 2 4
6 13 322.64 18 14.92 758 204 3.03 / 378.62 2 3
7 13 74.28 18 14.98 418 113 3.14 / 378.74 2 3
8 8 0.16 165 14.96 299 738 3.88 / 379.47 2 5
Average= 3.87
(KJ/cycle)

Cycle 96 GMT 7/ 4/2021 22:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.84 35 14.94 440 230 0.23 / 371.95 2 2
2 12 1168.92 4 15.11 1896 115 0.34 / 372.06 2 2
3 7 2005.80 36 14.71 2807 1486 1.83 / 373.55 2 3
4 13 1481.32 18 14.75 2216 588 2.42 / 374.14 2 3
5 13 961.76 18 14.79 1583 421 2.84 / 374.56 2 4
6 13 292.88 18 14.93 717 193 3.03 / 374.75 2 3
7 13 70.72 18 14.98 406 109 3.14 / 374.86 2 2
8 8 0.00 165 14.96 296 731 3.87 / 375.59 2 6
Average= 3.87
(KJ/cycle)

Cycle 95 GMT 29/ 3/2021 0: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 35 14.93 410 214 0.21 / 368.09 2 2
2 12 1177.64 4 15.12 1920 116 0.33 / 368.20 2 2
3 7 2002.80 36 14.71 2803 1484 1.81 / 369.69 2 3
4 13 1480.16 18 14.75 2213 588 2.40 / 370.28 2 3
5 13 960.68 18 14.79 1582 421 2.82 / 370.70 2 4
6 13 301.60 18 14.93 721 194 3.02 / 370.89 2 3
7 13 77.56 18 14.98 410 111 3.13 / 371.00 2 3
8 8 0.08 165 14.97 290 716 3.84 / 371.72 2 5
Average= 3.87
(KJ/cycle)

Cycle 94 GMT 19/ 3/2021 1:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 35 14.94 427 223 0.22 / 364.08 2 2
2 12 1171.16 4 15.12 1904 115 0.34 / 364.19 2 2
3 7 2006.20 36 14.71 2812 1489 1.83 / 365.68 2 4
4 13 1490.84 18 14.75 2228 592 2.42 / 366.27 2 3
5 13 978.48 18 14.79 1604 427 2.85 / 366.70 2 3
6 13 456.84 18 14.88 939 252 3.10 / 366.95 2 3
7 13 74.52 18 14.98 409 110 3.21 / 367.06 2 3
8 13 20.04 18 14.98 331 89 3.30 / 367.15 2 3
9 8 -0.04 165 14.95 294 725 4.02 / 367.87 2 6
Average= 3.87
(KJ/cycle)

Cycle 93 GMT 9/ 3/2021 3:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 35 14.93 429 224 0.22 / 360.14 2 2
2 12 1180.40 4 15.12 1924 116 0.34 / 360.26 2 2
3 7 2004.68 36 14.72 2813 1491 1.83 / 361.75 2 5
4 13 1498.80 18 14.75 2230 592 2.42 / 362.34 2 3
5 13 958.84 18 14.80 1582 421 2.84 / 362.77 2 3
6 13 441.48 18 14.89 922 247 3.09 / 363.01 2 3
7 13 74.60 18 14.99 411 111 3.20 / 363.12 2 3
8 8 0.12 165 14.97 295 729 3.93 / 363.85 2 6
Average= 3.87
(KJ/cycle)

Cycle 92 GMT 27/ 2/2021 5:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.56 35 14.93 455 238 0.24 / 356.20 2 2
2 12 1174.20 4 15.12 1909 115 0.35 / 356.31 2 2
3 7 2002.56 36 14.72 2805 1486 1.84 / 357.80 2 4
4 13 1486.92 18 14.76 2215 588 2.43 / 358.39 2 3
5 13 972.28 18 14.80 1598 426 2.85 / 358.82 2 3
6 13 468.04 18 14.89 959 257 3.11 / 359.07 2 3
7 13 67.08 18 14.99 407 110 3.22 / 359.18 2 3
8 8 0.12 165 14.97 299 739 3.96 / 359.92 2 5
Average= 3.87
(KJ/cycle)

Cycle 91 GMT 17/ 2/2021 7: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 35 14.93 452 236 0.24 / 352.23 2 2
2 12 1320.32 4 15.08 2115 128 0.36 / 352.36 2 2
3 7 2002.28 36 14.72 2807 1487 1.85 / 353.85 2 4
4 13 1494.44 18 14.75 2231 592 2.44 / 354.44 2 3
5 13 961.56 18 14.80 1589 423 2.87 / 354.86 2 3
6 13 432.12 18 14.90 913 245 3.11 / 355.11 2 4
7 13 57.20 18 14.99 397 107 3.22 / 355.22 2 3
8 8 0.20 165 14.97 302 746 3.96 / 355.96 2 7
Average= 3.87
(KJ/cycle)

Cycle 90 GMT 7/ 2/2021 8:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 35 14.94 443 232 0.23 / 348.35 2 2
2 12 1149.92 4 15.13 1867 113 0.34 / 348.46 2 2
3 7 2008.48 36 14.72 2807 1487 1.83 / 349.95 2 3
4 13 1365.24 18 14.77 2086 555 2.39 / 350.50 2 3
5 13 895.04 18 14.81 1505 401 2.79 / 350.91 2 3
6 13 394.88 18 14.90 866 232 3.02 / 351.14 2 3
7 13 49.96 18 14.99 392 106 3.13 / 351.24 2 3
8 8 -0.04 165 14.97 305 753 3.88 / 352.00 2 9
Average= 3.87
(KJ/cycle)

Cycle 89 GMT 28/ 1/2021 10:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 35 14.93 449 235 0.23 / 344.42 2 2
2 12 1163.48 4 15.12 1911 116 0.35 / 344.54 2 2
3 7 2001.72 37 14.72 2800 1525 1.88 / 346.06 2 4
4 13 1471.00 18 14.77 2205 586 2.46 / 346.65 2 3
5 13 959.68 18 14.80 1583 422 2.88 / 347.07 2 3
6 13 287.08 18 14.94 717 193 3.08 / 347.26 2 3
7 13 63.00 18 15.00 406 110 3.19 / 347.37 2 3
8 8 0.04 165 14.98 301 744 3.93 / 348.12 2 7
Average= 3.87
(KJ/cycle)

Cycle 88 GMT 18/ 1/2021 12:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 35 14.94 445 233 0.23 / 340.56 2 2
2 12 1170.96 4 15.13 1912 116 0.35 / 340.67 2 2
3 7 2008.08 36 14.73 2810 1490 1.84 / 342.17 2 3
4 13 1365.32 18 14.77 2072 551 2.39 / 342.72 2 3
5 13 878.84 18 14.82 1486 396 2.79 / 343.11 2 4
6 13 364.60 18 14.92 825 222 3.01 / 343.33 2 3
7 13 45.96 18 14.99 382 103 3.11 / 343.44 2 3
8 8 0.08 165 14.97 304 751 3.86 / 344.19 2 7
Average= 3.87
(KJ/cycle)

Cycle 87 GMT 8/ 1/2021 14: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 35 14.95 442 231 0.23 / 336.53 2 2
2 12 1167.68 4 15.13 1896 115 0.35 / 336.64 2 2
3 7 2003.16 37 14.73 2807 1530 1.88 / 338.17 2 4
4 13 1479.84 18 14.77 2203 586 2.46 / 338.76 2 3
5 13 832.32 18 14.84 1421 380 2.84 / 339.14 2 4
6 13 339.28 18 14.93 788 212 3.05 / 339.35 2 3
7 13 40.56 18 15.00 374 101 3.15 / 339.45 2 3
8 8 0.04 165 14.98 301 744 3.90 / 340.19 2 8
9 14 0.04 30 14.95 298 134 4.03 / 340.33 2 8
Average= 3.87
(KJ/cycle)

Cycle 86 GMT 29/12/2020 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.12 35 14.95 456 239 0.24 / 332.69 2 2
2 12 1171.84 4 15.14 1890 114 0.35 / 332.80 2 2
3 7 2006.56 36 14.73 2812 1491 1.84 / 334.29 2 2
4 13 1349.08 18 14.79 2056 547 2.39 / 334.84 2 3
5 13 873.60 18 14.82 1475 393 2.79 / 335.23 2 4
6 13 367.56 18 14.92 819 220 3.00 / 335.45 2 3
7 13 54.44 18 15.00 384 104 3.11 / 335.56 2 3
8 8 0.04 165 14.98 298 737 3.85 / 336.30 2 5
Average= 3.87
(KJ/cycle)

Cycle 85 GMT 19/12/2020 17:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 35 14.94 430 225 0.22 / 328.73 2 2
2 12 1163.48 4 15.14 1891 115 0.34 / 328.84 2 2
3 7 2004.00 37 14.74 2802 1528 1.87 / 330.37 2 2
4 13 1489.24 18 14.77 2226 592 2.46 / 330.96 2 3
5 13 986.20 18 14.81 1614 430 2.89 / 331.39 2 4
6 13 324.64 18 14.94 761 205 3.09 / 331.60 2 3
7 13 80.16 18 15.00 423 114 3.21 / 331.71 2 3
8 8 0.16 165 14.99 299 740 3.95 / 332.45 2 7
Average= 3.87
(KJ/cycle)

Cycle 84 GMT 9/12/2020 19:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 35 14.96 435 228 0.23 / 324.83 2 2
2 12 1154.80 4 15.15 1886 114 0.34 / 324.94 2 2
3 7 2006.68 36 14.73 2800 1485 1.83 / 326.43 2 3
4 13 1486.04 18 14.77 2220 590 2.42 / 327.02 2 3
5 13 984.32 18 14.81 1611 429 2.85 / 327.45 2 4
6 13 312.36 18 14.94 746 201 3.05 / 327.65 2 3
7 13 63.64 18 15.00 402 109 3.16 / 327.76 2 3
8 8 0.08 165 14.98 302 746 3.90 / 328.50 2 7
Average= 3.86
(KJ/cycle)

Cycle 83 GMT 29/11/2020 21: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 35 14.97 422 221 0.22 / 320.94 2 2
2 12 1188.32 4 15.15 1915 116 0.34 / 321.05 2 2
3 7 2005.52 36 14.74 2811 1492 1.83 / 322.54 2 3
4 13 1485.76 18 14.77 2219 590 2.42 / 323.13 2 3
5 13 969.92 18 14.82 1588 424 2.84 / 323.56 2 4
6 13 308.92 18 14.96 736 198 3.04 / 323.76 2 3
7 13 71.16 18 15.01 406 110 3.15 / 323.87 2 3
8 8 -0.04 165 14.99 297 735 3.88 / 324.60 2 9
Average= 3.86
(KJ/cycle)

Cycle 82 GMT 19/11/2020 23: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.72 35 14.97 450 236 0.24 / 317.05 2 2
2 12 1167.36 4 15.15 1881 114 0.35 / 317.16 2 2
3 7 2003.88 36 14.74 2809 1491 1.84 / 318.66 2 2
4 13 1490.60 18 14.78 2220 591 2.43 / 319.25 2 3
5 13 981.48 18 14.82 1605 428 2.86 / 319.67 2 3
6 13 324.28 18 14.95 756 203 3.06 / 319.88 2 3
7 13 93.48 18 15.01 433 117 3.18 / 319.99 2 3
8 8 0.24 165 15.00 291 720 3.90 / 320.71 2 5
Average= 3.86
(KJ/cycle)

Cycle 81 GMT 10/11/2020 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 35 14.97 452 237 0.24 / 313.01 2 2
2 12 1187.04 4 15.15 1938 117 0.35 / 313.12 2 2
3 7 2003.20 36 14.75 2809 1492 1.85 / 314.62 2 2
4 13 1483.68 18 14.79 2219 591 2.44 / 315.21 2 4
5 13 966.28 18 14.83 1595 426 2.86 / 315.63 2 4
6 13 303.04 18 14.97 731 197 3.06 / 315.83 2 3
7 13 66.80 18 15.02 405 109 3.17 / 315.94 2 3
8 8 0.12 165 15.00 300 742 3.91 / 316.68 2 7
9 14 0.12 30 14.98 297 133 4.04 / 316.82 2 9
Average= 3.86
(KJ/cycle)

Cycle 80 GMT 31/10/2020 2:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 35 14.96 455 238 0.24 / 309.11 2 2
2 12 1169.84 4 15.15 1911 116 0.35 / 309.22 2 2
3 7 2001.92 36 14.75 2802 1488 1.84 / 310.71 2 2
4 13 1475.16 18 14.78 2210 588 2.43 / 311.30 2 3
5 13 956.12 18 14.83 1575 420 2.85 / 311.72 2 4
6 13 302.76 18 14.97 729 196 3.05 / 311.92 2 3
7 13 69.64 18 15.03 409 111 3.16 / 312.03 2 3
8 8 0.08 165 15.01 300 743 3.90 / 312.77 2 3
Average= 3.86
(KJ/cycle)

Cycle 79 GMT 21/10/2020 4:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 35 14.97 434 227 0.23 / 305.16 2 2
2 12 1178.32 4 15.14 1920 116 0.34 / 305.28 2 2
3 7 2002.76 36 14.75 2803 1488 1.83 / 306.76 2 2
4 13 1467.04 18 14.79 2196 585 2.42 / 307.35 2 4
5 13 946.80 18 14.83 1571 419 2.84 / 307.77 2 3
6 13 425.72 18 14.93 900 242 3.08 / 308.01 2 4
7 13 54.76 18 15.03 391 106 3.18 / 308.12 2 3
8 8 0.04 165 15.00 305 755 3.94 / 308.87 2 6
Average= 3.86
(KJ/cycle)

Cycle 78 GMT 11/10/2020 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.96 35 14.97 456 239 0.24 / 301.29 2 2
2 12 1172.12 4 15.16 1897 115 0.35 / 301.41 2 2
3 7 2002.68 36 14.75 2800 1487 1.84 / 302.89 2 2
4 13 1484.96 18 14.79 2214 589 2.43 / 303.48 2 3
5 13 841.16 18 14.85 1437 384 2.81 / 303.87 2 3
6 13 345.20 18 14.96 788 212 3.03 / 304.08 2 3
7 13 83.36 18 15.03 427 116 3.14 / 304.19 2 3
8 8 0.00 165 15.01 298 738 3.88 / 304.93 2 6
Average= 3.86
(KJ/cycle)

Cycle 77 GMT 1/10/2020 8:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 34 14.99 451 230 0.23 / 297.41 2 2
2 12 1170.32 4 15.15 1917 116 0.35 / 297.53 2 2
3 7 2007.40 36 14.75 2801 1487 1.83 / 299.01 2 2
4 13 1352.44 18 14.81 2064 550 2.38 / 299.56 2 3
5 13 879.04 18 14.85 1486 397 2.78 / 299.96 2 3
6 13 379.20 18 14.95 833 224 3.00 / 300.19 2 3
7 13 97.12 18 15.02 445 120 3.13 / 300.31 2 3
8 8 0.16 165 15.01 301 745 3.87 / 301.05 2 6
Average= 3.86
(KJ/cycle)

Cycle 76 GMT 21/ 9/2020 10:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 34 14.99 437 223 0.22 / 293.52 2 2
2 12 1168.56 4 15.15 1890 115 0.34 / 293.63 2 2
3 7 2002.36 36 14.75 2797 1485 1.82 / 295.12 2 2
4 13 1354.64 18 14.81 2061 549 2.37 / 295.67 2 3
5 13 1015.00 18 14.83 1649 440 2.81 / 296.11 2 3
6 13 352.00 18 14.97 794 214 3.03 / 296.32 2 3
7 13 91.72 18 15.04 435 118 3.14 / 296.44 2 3
8 8 0.00 165 15.02 299 741 3.88 / 297.18 2 3
Average= 3.86
(KJ/cycle)

Cycle 75 GMT 11/ 9/2020 12: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 34 14.99 457 233 0.23 / 289.55 2 2
2 12 1178.80 4 15.16 1917 116 0.35 / 289.67 2 2
3 7 2003.40 36 14.77 2808 1493 1.84 / 291.16 2 2
4 13 1493.60 18 14.79 2229 593 2.44 / 291.75 2 3
5 13 986.68 18 14.84 1624 434 2.87 / 292.19 2 3
6 13 467.12 18 14.95 953 256 3.13 / 292.44 2 3
7 13 82.12 18 15.05 420 114 3.24 / 292.56 2 3
8 8 0.12 165 15.03 298 739 3.98 / 293.30 2 6
Average= 3.86
(KJ/cycle)

Cycle 74 GMT 1/ 9/2020 13:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 34 15.00 446 227 0.23 / 285.67 2 2
2 12 1168.48 4 15.16 1901 115 0.34 / 285.79 2 2
3 7 2004.84 36 14.75 2805 1489 1.83 / 287.28 2 3
4 13 1476.80 18 14.80 2207 588 2.42 / 287.87 2 3
5 13 828.00 18 14.87 1423 381 2.80 / 288.25 2 3
6 13 340.56 18 14.98 780 210 3.01 / 288.46 2 3
7 13 78.88 18 15.05 420 114 3.13 / 288.57 2 3
8 8 0.16 165 15.03 301 746 3.87 / 289.32 2 5
Average= 3.86
(KJ/cycle)

Cycle 73 GMT 22/ 8/2020 15:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 34 14.99 463 236 0.24 / 281.77 2 2
2 12 1164.64 4 15.16 1914 116 0.35 / 281.88 2 2
3 7 2005.72 36 14.76 2808 1492 1.84 / 283.37 2 2
4 13 1484.04 18 14.79 2214 589 2.43 / 283.96 2 3
5 13 972.60 18 14.85 1593 426 2.86 / 284.39 2 4
6 13 313.72 18 15.00 745 201 3.06 / 284.59 2 3
7 13 70.36 18 15.06 410 111 3.17 / 284.70 2 3
8 8 0.12 165 15.04 300 744 3.92 / 285.45 2 7
Average= 3.86
(KJ/cycle)

Cycle 72 GMT 12/ 8/2020 17:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 34 15.01 446 228 0.23 / 277.90 2 2
2 12 1169.68 4 15.17 1922 117 0.34 / 278.02 2 2
3 7 2004.28 36 14.76 2805 1490 1.83 / 279.51 2 3
4 13 1349.60 18 14.81 2054 548 2.38 / 280.06 2 3
5 13 863.80 18 14.87 1465 392 2.77 / 280.45 2 3
6 13 362.96 18 14.98 821 221 3.00 / 280.67 2 3
7 13 42.76 18 15.06 374 101 3.10 / 280.77 2 2
8 8 0.04 165 15.03 306 759 3.86 / 281.53 2 6
Average= 3.86
(KJ/cycle)

Cycle 71 GMT 2/ 8/2020 19:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 34 15.01 445 227 0.23 / 273.94 2 2
2 12 1173.64 4 15.16 1911 116 0.34 / 274.06 2 2
3 7 2001.96 36 14.75 2800 1487 1.83 / 275.55 2 2
4 13 1489.36 18 14.80 2218 591 2.42 / 276.14 2 3
5 13 979.68 18 14.85 1605 429 2.85 / 276.57 2 4
6 13 451.00 18 14.96 935 252 3.10 / 276.82 2 3
7 13 64.80 18 15.06 401 109 3.21 / 276.93 2 3
8 8 0.04 165 15.04 301 747 3.96 / 277.67 2 5
Average= 3.86
(KJ/cycle)

Cycle 70 GMT 23/ 7/2020 20:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 34 15.02 452 231 0.23 / 270.00 2 2
2 12 1176.16 4 15.16 1915 116 0.35 / 270.11 2 2
3 7 2003.80 36 14.76 2807 1492 1.84 / 271.60 2 2
4 13 1468.52 18 14.81 2196 585 2.42 / 272.19 2 3
5 13 948.40 18 14.86 1567 419 2.84 / 272.61 2 3
6 13 419.44 18 14.97 893 241 3.08 / 272.85 2 3
7 13 120.36 18 15.05 474 128 3.21 / 272.98 2 3
8 8 0.00 165 15.04 298 740 3.95 / 273.72 2 9
Average= 3.86
(KJ/cycle)

Cycle 69 GMT 13/ 7/2020 22:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 34 15.02 452 231 0.23 / 265.91 2 2
2 12 1176.56 4 15.16 1931 117 0.35 / 266.03 2 2
3 7 2003.08 36 14.77 2800 1489 1.84 / 267.51 2 2
4 13 1483.92 18 14.81 2215 590 2.43 / 268.10 2 3
5 13 963.36 18 14.86 1586 424 2.85 / 268.53 2 4
6 13 444.92 18 14.97 927 250 3.10 / 268.78 2 3
7 13 70.36 18 15.07 402 109 3.21 / 268.89 2 2
8 8 0.08 165 15.05 299 742 3.95 / 269.63 2 6
9 14 0.08 30 15.03 298 134 4.09 / 269.76 3 9
Average= 3.85
(KJ/cycle)

Cycle 68 GMT 4/ 7/2020 0:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 34 15.02 436 223 0.22 / 261.93 2 2
2 12 1179.24 4 15.17 1908 116 0.34 / 262.05 2 2
3 7 2001.76 36 14.77 2796 1487 1.83 / 263.53 2 2
4 13 1472.56 18 14.81 2198 586 2.41 / 264.12 2 3
5 13 956.32 18 14.86 1579 422 2.83 / 264.54 2 4
6 13 438.28 18 14.97 922 248 3.08 / 264.79 2 3
7 13 126.76 18 15.06 485 131 3.21 / 264.92 2 3
8 8 0.20 165 15.05 304 755 3.97 / 265.68 2 5
Average= 3.85
(KJ/cycle)

Cycle 67 GMT 24/ 6/2020 2:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 34 15.02 427 218 0.22 / 257.95 2 2
2 12 1167.52 4 15.17 1914 116 0.33 / 258.07 2 2
3 7 2002.60 36 14.77 2801 1489 1.82 / 259.56 2 2
4 13 1481.24 18 14.81 2213 590 2.41 / 260.15 2 3
5 13 966.40 18 14.86 1591 426 2.84 / 260.57 2 4
6 13 441.16 18 14.97 932 251 3.09 / 260.83 2 3
7 13 123.76 18 15.06 486 132 3.22 / 260.96 2 3
8 8 -0.04 165 15.05 303 752 3.97 / 261.71 2 4
Average= 3.85
(KJ/cycle)

Cycle 66 GMT 14/ 6/2020 4:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 34 15.04 426 218 0.22 / 254.01 2 2
2 12 1172.32 4 15.17 1897 115 0.33 / 254.12 2 2
3 7 2007.32 36 14.77 2808 1493 1.83 / 255.61 2 3
4 13 1481.32 18 14.81 2210 589 2.42 / 256.20 2 3
5 13 962.68 18 14.87 1584 424 2.84 / 256.63 2 4
6 13 437.56 18 14.98 925 249 3.09 / 256.88 2 3
7 13 76.24 18 15.08 416 113 3.20 / 256.99 2 3
8 8 0.04 165 15.06 300 745 3.95 / 257.74 2 4
Average= 3.85
(KJ/cycle)

Cycle 65 GMT 4/ 6/2020 6:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.16 34 15.04 453 232 0.23 / 250.05 2 2
2 12 1172.12 4 15.17 1914 116 0.35 / 250.16 2 2
3 7 2003.12 37 14.77 2807 1534 1.88 / 251.70 2 2
4 13 1493.80 18 14.81 2217 591 2.47 / 252.29 2 3
5 13 974.08 18 14.87 1604 429 2.90 / 252.72 2 4
6 13 321.08 18 15.02 760 205 3.11 / 252.92 2 3
7 13 96.48 18 15.08 443 120 3.23 / 253.04 2 3
8 8 0.08 165 15.07 299 743 3.97 / 253.79 2 5
Average= 3.85
(KJ/cycle)

Cycle 64 GMT 25/ 5/2020 8: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 34 15.05 443 227 0.23 / 246.12 2 2
2 12 1180.32 4 15.17 1923 117 0.34 / 246.24 2 2
3 7 2002.60 37 14.78 2805 1534 1.88 / 247.77 2 3
4 13 1357.04 18 14.83 2075 554 2.43 / 248.32 2 3
5 13 866.16 18 14.89 1472 395 2.83 / 248.72 2 3
6 13 362.64 18 15.01 822 222 3.05 / 248.94 2 3
7 13 99.64 18 15.08 455 124 3.17 / 249.06 2 3
8 8 0.08 165 15.07 303 753 3.92 / 249.82 2 6
Average= 3.84
(KJ/cycle)

Cycle 63 GMT 15/ 5/2020 9:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 34 15.05 422 216 0.22 / 242.15 2 2
2 12 1179.32 4 15.18 1910 116 0.33 / 242.27 2 2
3 7 2002.36 36 14.78 2797 1488 1.82 / 243.75 2 2
4 13 1486.40 18 14.81 2224 593 2.41 / 244.35 2 3
5 13 973.40 18 14.87 1605 430 2.84 / 244.78 2 4
6 13 443.04 18 14.99 933 252 3.09 / 245.03 2 3
7 13 92.60 18 15.09 442 120 3.21 / 245.15 2 3
8 8 0.12 165 15.08 299 744 3.96 / 245.89 2 6
Average= 3.84
(KJ/cycle)

Cycle 62 GMT 5/ 5/2020 11:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 34 15.04 440 225 0.22 / 238.19 2 2
2 12 1169.24 4 15.18 1919 117 0.34 / 238.31 2 2
3 7 2006.80 36 14.78 2803 1491 1.83 / 239.80 2 2
4 13 1484.52 18 14.82 2217 591 2.42 / 240.39 2 3
5 13 962.96 18 14.88 1592 426 2.85 / 240.82 2 4
6 13 440.88 18 14.99 922 249 3.10 / 241.06 2 4
7 13 77.72 18 15.10 423 115 3.21 / 241.18 2 3
8 8 0.24 165 15.08 303 754 3.97 / 241.93 2 6
Average= 3.84
(KJ/cycle)

Cycle 61 GMT 25/ 4/2020 13:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.16 34 15.05 455 233 0.23 / 234.28 2 2
2 12 1190.16 4 15.17 1934 117 0.35 / 234.40 2 2
3 7 2008.52 36 14.77 2816 1497 1.85 / 235.90 2 2
4 13 1351.24 18 14.84 2064 551 2.40 / 236.45 2 3
5 13 874.92 18 14.90 1488 399 2.80 / 236.85 2 3
6 13 367.84 18 15.01 832 225 3.02 / 237.07 2 3
7 13 93.40 18 15.09 451 123 3.15 / 237.20 2 3
8 8 0.04 165 15.08 309 769 3.91 / 237.97 2 5
Average= 3.84
(KJ/cycle)

Cycle 60 GMT 15/ 4/2020 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 34 15.05 432 221 0.22 / 230.37 2 2
2 12 1168.96 4 15.18 1904 116 0.34 / 230.49 2 2
3 7 2003.36 36 14.78 2801 1490 1.83 / 231.98 2 2
4 13 1345.12 18 14.85 2044 546 2.37 / 232.53 2 3
5 13 1014.56 18 14.87 1653 442 2.82 / 232.97 2 4
6 13 329.24 18 15.04 774 210 3.03 / 233.18 2 3
7 13 78.32 18 15.10 425 116 3.14 / 233.29 2 3
8 8 0.12 165 15.09 304 757 3.90 / 234.05 2 5
Average= 3.84
(KJ/cycle)

Cycle 59 GMT 5/ 4/2020 16: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 34 15.06 426 218 0.22 / 226.54 2 2
2 12 1166.88 4 15.19 1910 116 0.33 / 226.65 2 2
3 7 1987.36 36 14.77 2791 1484 1.82 / 228.14 2 2
4 13 1330.84 18 14.85 2037 544 2.36 / 228.68 2 3
5 13 860.52 18 14.91 1466 393 2.76 / 229.07 2 4
6 13 348.28 18 15.03 801 217 2.97 / 229.29 2 3
7 13 52.32 18 15.11 390 106 3.08 / 229.40 2 3
8 8 0.04 165 15.09 304 757 3.84 / 230.15 2 7
Average= 3.84
(KJ/cycle)

Cycle 58 GMT 26/ 3/2020 15: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 34 15.07 425 218 0.22 / 222.58 2 2
2 12 1159.48 4 15.18 1895 115 0.33 / 222.69 2 2
3 7 2003.28 36 14.78 2812 1496 1.83 / 224.19 2 2
4 13 1486.40 18 14.83 2220 593 2.42 / 224.78 2 3
5 13 955.48 18 14.89 1579 423 2.84 / 225.21 2 4
6 13 444.24 18 15.01 927 250 3.10 / 225.46 2 3
7 13 70.24 18 15.11 407 111 3.21 / 225.57 2 3
8 8 0.00 165 15.09 301 749 3.96 / 226.32 2 10
Average= 3.84
(KJ/cycle)

Cycle 57 GMT 16/ 3/2020 16:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 34 15.07 422 216 0.22 / 218.62 2 2
2 12 1164.72 4 15.20 1908 116 0.33 / 218.74 2 2
3 7 1978.92 36 14.78 2793 1486 1.82 / 220.23 2 3
4 13 1472.48 18 14.83 2207 589 2.41 / 220.81 2 3
5 13 955.24 18 14.90 1581 424 2.83 / 221.24 2 3
6 13 314.16 18 15.06 746 202 3.03 / 221.44 2 3
7 13 104.96 18 15.11 444 121 3.15 / 221.56 2 3
8 13 15.12 18 15.13 314 86 3.24 / 221.65 2 3
9 8 0.16 165 15.10 287 715 3.96 / 222.36 2 6
Average= 3.83
(KJ/cycle)

Cycle 56 GMT 6/ 3/2020 15:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 34 15.09 420 215 0.22 / 214.53 2 2
2 12 1172.64 4 15.19 1926 117 0.33 / 214.65 2 2
3 7 2001.64 37 14.79 2796 1530 1.86 / 216.18 2 2
4 13 1490.48 18 14.83 2223 593 2.46 / 216.77 2 3
5 13 975.92 18 14.89 1599 429 2.88 / 217.20 2 3
6 13 443.84 18 15.02 918 248 3.13 / 217.45 2 3
7 13 130.80 18 15.10 484 132 3.26 / 217.58 2 3
8 13 33.28 18 15.12 347 94 3.36 / 217.68 2 2
9 8 0.08 165 15.10 293 730 4.09 / 218.41 2 5
Average= 3.83
(KJ/cycle)

Cycle 55 GMT 25/ 2/2020 17:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 34 15.09 421 216 0.22 / 210.68 2 2
2 12 1170.72 4 15.19 1909 116 0.33 / 210.80 2 2
3 7 1801.36 36 14.85 2582 1380 1.71 / 212.18 2 3
4 13 1476.92 18 14.86 2212 592 2.30 / 212.77 2 3
5 13 953.60 18 14.93 1579 424 2.73 / 213.20 2 3
6 13 297.00 18 15.09 716 194 2.92 / 213.39 2 3
7 13 82.36 18 15.14 416 113 3.04 / 213.50 2 3
8 13 22.80 18 15.15 330 90 3.13 / 213.59 2 3
9 8 0.12 165 15.12 290 723 3.85 / 214.32 2 8
Average= 3.83
(KJ/cycle)

Cycle 54 GMT 15/ 2/2020 17:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 34 15.08 426 218 0.22 / 206.90 2 2
2 12 1187.76 4 15.19 1929 117 0.34 / 207.02 2 2
3 7 1866.00 36 14.82 2653 1415 1.75 / 208.44 2 2
4 13 1374.24 18 14.87 2089 559 2.31 / 209.00 2 3
5 13 860.36 18 14.94 1469 395 2.71 / 209.39 2 4
6 13 353.60 18 15.06 805 218 2.92 / 209.61 2 3
7 13 86.76 18 15.13 433 118 3.04 / 209.73 2 3
8 8 0.08 165 15.12 297 741 3.78 / 210.47 2 6
Average= 3.83
(KJ/cycle)

Cycle 53 GMT 5/ 2/2020 16:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 34 15.08 453 232 0.23 / 203.02 2 2
2 12 1172.84 4 15.19 1903 116 0.35 / 203.14 2 2
3 7 1856.52 36 14.83 2639 1409 1.76 / 204.55 2 2
4 13 1370.16 18 14.88 2082 558 2.31 / 205.11 2 3
5 13 880.72 18 14.94 1490 401 2.72 / 205.51 2 3
6 13 365.32 18 15.06 827 224 2.94 / 205.73 2 3
7 13 56.72 18 15.14 397 108 3.05 / 205.84 2 3
8 13 16.56 18 15.14 334 91 3.14 / 205.93 2 3
9 8 -0.04 165 15.11 303 755 3.89 / 206.69 2 8
Average= 3.83
(KJ/cycle)

Cycle 52 GMT 26/ 1/2020 16:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 34 15.09 441 226 0.23 / 199.12 2 2
2 12 1180.84 4 15.20 1923 117 0.34 / 199.24 2 2
3 7 1933.12 36 14.82 2730 1457 1.80 / 200.69 2 2
4 13 1438.44 18 14.86 2153 576 2.38 / 201.27 2 3
5 13 929.68 18 14.92 1551 417 2.79 / 201.69 2 4
6 13 416.28 18 15.04 893 242 3.03 / 201.93 2 4
7 13 62.48 18 15.14 402 110 3.14 / 202.04 2 3
8 8 0.16 165 15.12 303 756 3.90 / 202.79 2 8
Average= 3.83
(KJ/cycle)

Cycle 51 GMT 16/ 1/2020 15:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 34 15.10 455 234 0.23 / 195.21 2 2
2 12 1166.84 4 15.20 1910 116 0.35 / 195.33 2 2
3 7 2006.08 36 14.80 2816 1500 1.85 / 196.83 2 2
4 13 1478.04 18 14.85 2210 591 2.44 / 197.42 2 3
5 13 948.40 18 14.92 1573 422 2.86 / 197.84 2 3
6 13 285.96 18 15.09 712 193 3.06 / 198.03 2 3
7 13 63.52 18 15.14 401 109 3.17 / 198.14 2 3
8 8 0.00 165 15.12 301 751 3.92 / 198.89 2 5
Average= 3.82
(KJ/cycle)

Cycle 50 GMT 6/ 1/2020 17:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 34 15.09 427 219 0.22 / 191.61 2 2
2 12 1159.20 4 15.20 1901 116 0.33 / 191.72 2 2
3 7 1621.24 36 14.92 2364 1270 1.60 / 192.99 2 3
4 13 1316.60 18 14.93 2018 542 2.15 / 193.53 2 3
5 13 831.92 18 14.99 1425 384 2.53 / 193.92 2 3
6 13 311.28 18 15.11 749 204 2.73 / 194.12 2 4
7 13 36.12 18 15.17 363 99 2.83 / 194.22 2 3
8 8 0.00 165 15.14 302 754 3.59 / 194.98 2 7
Average= 3.82
(KJ/cycle)

Cycle 49 GMT 27/12/2019 17:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 34 15.10 439 225 0.23 / 187.75 2 2
2 12 1167.32 4 15.20 1922 117 0.34 / 187.87 2 2
3 7 2003.84 36 14.80 2807 1496 1.84 / 189.37 2 2
4 13 1343.64 18 14.87 2049 548 2.39 / 189.91 2 3
5 13 862.88 18 14.94 1468 395 2.78 / 190.31 2 3
6 13 358.88 18 15.06 815 221 3.00 / 190.53 2 3
7 13 45.56 18 15.15 382 104 3.11 / 190.63 2 3
8 8 0.08 165 15.12 302 753 3.86 / 191.39 2 4
Average= 3.83
(KJ/cycle)

Cycle 48 GMT 17/12/2019 18:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 34 15.10 432 222 0.22 / 183.75 2 2
2 12 1162.12 4 15.20 1902 116 0.34 / 183.87 2 2
3 7 2003.36 36 14.80 2806 1495 1.83 / 185.36 2 2
4 13 1475.76 18 14.86 2206 590 2.42 / 185.95 2 3
5 13 822.72 18 14.96 1412 380 2.80 / 186.33 2 3
6 13 329.56 18 15.08 772 210 3.01 / 186.54 2 3
7 13 41.72 18 15.16 372 102 3.11 / 186.64 2 3
8 8 0.08 165 15.13 301 751 3.87 / 187.39 2 6
9 14 0.08 30 15.11 298 135 4.00 / 187.53 2 6
Average= 3.83
(KJ/cycle)

Cycle 47 GMT 7/12/2019 20:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 34 15.11 448 230 0.23 / 179.85 2 2
2 12 1162.48 4 15.20 1890 115 0.35 / 179.97 2 2
3 7 2003.24 36 14.81 2811 1499 1.84 / 181.47 2 2
4 13 1467.40 18 14.86 2204 590 2.43 / 182.06 2 3
5 13 928.76 18 14.93 1547 416 2.85 / 182.47 2 3
6 13 282.88 18 15.10 711 193 3.04 / 182.67 2 3
7 13 60.12 18 15.15 399 109 3.15 / 182.77 2 3
8 8 0.04 165 15.13 302 754 3.91 / 183.53 2 5
Average= 3.82
(KJ/cycle)

Cycle 46 GMT 27/11/2019 22: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.48 34 15.10 452 232 0.23 / 176.23 2 2
2 12 1169.80 4 15.21 1892 115 0.35 / 176.34 2 2
3 7 1710.24 36 14.90 2466 1323 1.67 / 177.67 2 2
4 13 1386.72 18 14.92 2094 562 2.23 / 178.23 2 3
5 13 738.84 18 15.01 1314 355 2.59 / 178.58 2 3
6 13 251.72 18 15.13 667 182 2.77 / 178.77 2 3
7 13 27.76 18 15.18 355 97 2.87 / 178.86 2 2
8 8 0.08 165 15.15 304 760 3.63 / 179.62 2 5
Average= 3.82
(KJ/cycle)

Cycle 45 GMT 17/11/2019 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 34 15.11 447 230 0.23 / 172.27 2 2
2 12 1166.52 4 15.21 1898 115 0.35 / 172.38 2 2
3 7 2002.44 36 14.81 2801 1493 1.84 / 173.88 2 2
4 13 1475.48 18 14.86 2201 589 2.43 / 174.47 2 3
5 13 949.12 18 14.93 1574 423 2.85 / 174.89 2 3
6 13 425.84 18 15.06 907 246 3.10 / 175.14 2 3
7 13 53.80 18 15.16 392 107 3.20 / 175.24 2 3
8 8 0.16 165 15.14 302 754 3.96 / 176.00 2 5
Average= 3.83
(KJ/cycle)

Cycle 44 GMT 7/11/2019 23:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 34 15.11 454 233 0.23 / 168.37 2 2
2 12 1160.60 4 15.21 1897 115 0.35 / 168.48 2 2
3 7 2001.64 36 14.82 2798 1493 1.84 / 169.98 2 2
4 13 1476.16 18 14.87 2212 592 2.43 / 170.57 2 3
5 13 948.48 18 14.94 1568 422 2.86 / 170.99 2 3
6 13 304.48 18 15.10 736 200 3.06 / 171.19 2 3
7 13 35.28 18 15.17 359 98 3.15 / 171.29 2 3
8 8 0.12 165 15.14 301 752 3.91 / 172.04 2 6
Average= 3.82
(KJ/cycle)

Cycle 43 GMT 29/10/2019 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 34 15.11 448 230 0.23 / 164.45 2 2
2 12 1166.00 4 15.22 1906 116 0.35 / 164.57 2 2
3 7 2001.92 36 14.81 2801 1493 1.84 / 166.06 2 2
4 13 1474.48 18 14.87 2204 590 2.43 / 166.65 2 3
5 13 961.00 18 14.94 1589 427 2.86 / 167.08 2 3
6 13 300.68 18 15.11 726 197 3.05 / 167.28 2 3
7 13 66.64 18 15.16 402 110 3.16 / 167.39 2 2
8 8 0.12 165 15.15 299 747 3.91 / 168.13 2 4
Average= 3.82
(KJ/cycle)

Cycle 42 GMT 19/10/2019 2:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 34 15.11 458 235 0.24 / 160.48 2 2
2 12 1176.24 4 15.21 1910 116 0.35 / 160.59 2 2
3 7 2003.60 36 14.82 2808 1498 1.85 / 162.09 2 2
4 13 1485.52 18 14.87 2211 592 2.44 / 162.68 2 3
5 13 965.76 18 14.94 1594 429 2.87 / 163.11 2 3
6 13 443.24 18 15.06 930 252 3.12 / 163.37 2 3
7 13 60.80 18 15.16 393 107 3.23 / 163.47 2 3
8 8 0.20 165 15.15 300 750 3.98 / 164.22 2 5
Average= 3.82
(KJ/cycle)

Cycle 41 GMT 9/10/2019 4:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 34 15.12 447 230 0.23 / 156.63 2 2
2 12 1166.84 4 15.22 1900 116 0.35 / 156.74 2 2
3 7 2004.20 36 14.82 2803 1495 1.84 / 158.24 2 2
4 13 1320.40 18 14.90 2030 544 2.39 / 158.78 2 3
5 13 853.60 18 14.97 1455 392 2.78 / 159.17 2 3
6 13 356.44 18 15.09 804 218 3.00 / 159.39 2 3
7 13 43.92 18 15.17 370 101 3.10 / 159.49 2 2
8 8 0.16 165 15.15 300 750 3.85 / 160.24 2 6
Average= 3.82
(KJ/cycle)

Cycle 40 GMT 29/ 9/2019 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 34 15.12 437 225 0.22 / 152.72 2 2
2 12 1171.48 4 15.22 1905 116 0.34 / 152.84 2 2
3 7 2003.08 36 14.82 2798 1493 1.83 / 154.33 2 2
4 13 1478.44 18 14.87 2209 591 2.42 / 154.92 2 3
5 13 957.48 18 14.95 1582 426 2.85 / 155.35 2 3
6 13 294.84 18 15.12 724 197 3.05 / 155.54 2 3
7 13 32.32 18 15.18 356 97 3.14 / 155.64 2 3
8 8 0.04 165 15.15 302 755 3.90 / 156.40 2 5
Average= 3.81
(KJ/cycle)

Cycle 39 GMT 19/ 9/2019 7:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 34 15.12 454 233 0.23 / 148.82 2 2
2 12 1165.40 4 15.22 1905 116 0.35 / 148.94 2 2
3 7 2004.76 36 14.83 2803 1496 1.85 / 150.43 2 2
4 13 1485.40 18 14.88 2222 595 2.44 / 151.03 2 3
5 13 823.32 18 14.99 1419 383 2.82 / 151.41 2 4
6 13 340.32 18 15.10 784 213 3.04 / 151.63 2 3
7 13 82.80 18 15.17 429 117 3.15 / 151.74 2 3
8 8 0.16 165 15.15 302 755 3.91 / 152.50 2 6
Average= 3.81
(KJ/cycle)

Cycle 38 GMT 9/ 9/2019 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 34 15.13 437 225 0.22 / 145.06 2 2
2 12 1152.56 4 15.23 1889 115 0.34 / 145.17 2 2
3 7 2003.60 36 14.83 2800 1495 1.83 / 146.67 2 2
4 13 1324.92 18 14.91 2033 546 2.38 / 147.21 2 3
5 13 850.40 18 14.97 1451 391 2.77 / 147.60 2 4
6 13 347.28 18 15.10 800 217 2.99 / 147.82 2 3
7 8 0.16 165 15.15 307 767 3.76 / 148.59 2 6
Average= 3.81
(KJ/cycle)

Cycle 37 GMT 30/ 8/2019 10:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.64 34 15.13 450 231 0.23 / 141.21 2 2
2 12 1161.56 4 15.23 1899 116 0.35 / 141.32 2 2
3 7 2003.84 36 14.83 2806 1498 1.85 / 142.82 2 2
4 13 1469.44 18 14.88 2202 590 2.44 / 143.41 2 3
5 13 953.00 18 14.96 1576 424 2.86 / 143.84 2 3
6 13 423.16 18 15.08 896 243 3.10 / 144.08 2 3
7 8 0.08 165 15.17 301 753 3.86 / 144.83 2 8
Average= 3.81
(KJ/cycle)

Cycle 36 GMT 20/ 8/2019 11:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 34 15.13 453 233 0.23 / 137.21 2 2
2 12 1180.64 4 15.24 1912 117 0.35 / 137.33 2 2
3 7 2002.68 37 14.83 2804 1539 1.89 / 138.87 2 2
4 13 1485.84 18 14.89 2217 594 2.48 / 139.46 2 3
5 13 953.72 18 14.96 1568 422 2.90 / 139.88 2 3
6 13 423.40 18 15.09 891 242 3.15 / 140.13 2 3
7 13 59.92 18 15.18 389 106 3.25 / 140.23 2 3
8 8 0.20 165 15.17 297 743 4.00 / 140.98 2 5
Average= 3.81
(KJ/cycle)

Cycle 35 GMT 10/ 8/2019 13:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 34 15.14 450 232 0.23 / 133.30 2 2
2 12 1178.36 4 15.24 1925 117 0.35 / 133.42 2 2
3 7 2002.12 36 14.84 2800 1496 1.84 / 134.91 2 2
4 13 1468.12 18 14.89 2191 587 2.43 / 135.50 2 3
5 13 960.40 18 14.97 1583 427 2.86 / 135.93 2 3
6 13 302.92 18 15.13 728 198 3.06 / 136.12 2 3
7 13 76.28 18 15.18 412 113 3.17 / 136.24 2 3
8 8 0.00 165 15.17 297 743 3.91 / 136.98 2 8
Average= 3.80
(KJ/cycle)

Cycle 34 GMT 31/ 7/2019 14:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 34 15.14 444 229 0.23 / 129.38 2 2
2 3 1021.68 1 15.20 1719 26 0.25 / 129.41 2 2
3 12 1167.44 4 15.24 1888 115 0.37 / 129.52 2 2
4 7 2001.56 36 14.84 2807 1500 1.87 / 131.02 2 2
5 13 1333.68 18 14.91 2044 549 2.42 / 131.57 2 3
6 13 989.72 18 14.96 1621 437 2.85 / 132.01 2 3
7 13 311.92 18 15.13 741 202 3.06 / 132.21 2 3
8 13 70.56 18 15.19 407 111 3.17 / 132.32 2 3
9 8 0.16 165 15.17 298 746 3.91 / 133.07 2 8
Average= 3.80
(KJ/cycle)

Cycle 33 GMT 21/ 7/2019 16:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 33 15.14 447 223 0.22 / 125.33 2 2
2 12 1176.76 4 15.24 1924 117 0.34 / 125.45 2 2
3 7 2002.96 36 14.84 2811 1502 1.84 / 126.95 2 2
4 13 1464.36 18 14.90 2195 589 2.43 / 127.54 2 3
5 13 949.80 18 14.98 1572 424 2.85 / 127.97 2 3
6 13 296.92 18 15.14 719 196 3.05 / 128.16 2 3
7 13 73.60 18 15.19 406 111 3.16 / 128.27 2 3
8 8 0.08 165 15.18 298 746 3.91 / 129.02 2 5
9 14 0.08 30 15.15 296 135 4.04 / 129.15 2 7
Average= 3.80
(KJ/cycle)

Cycle 32 GMT 11/ 7/2019 17:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 33 15.14 451 225 0.23 / 121.40 2 2
2 12 1172.96 4 15.24 1913 117 0.34 / 121.51 2 2
3 7 2001.84 36 14.85 2812 1503 1.85 / 123.02 2 2
4 13 1482.16 18 14.89 2216 594 2.44 / 123.61 2 3
5 13 964.08 18 14.97 1594 430 2.87 / 124.04 2 4
6 13 304.04 18 15.14 742 202 3.07 / 124.24 2 3
7 13 79.00 18 15.19 421 115 3.19 / 124.36 2 3
8 8 0.12 165 15.17 301 753 3.94 / 125.11 2 6
Average= 3.79
(KJ/cycle)

Cycle 31 GMT 1/ 7/2019 19:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 33 15.14 429 214 0.21 / 117.50 2 2
2 12 1167.80 4 15.24 1919 117 0.33 / 117.61 2 2
3 7 2003.72 36 14.85 2809 1502 1.83 / 119.12 2 2
4 13 1465.00 18 14.91 2183 586 2.42 / 119.70 2 3
5 13 944.76 18 14.98 1561 421 2.84 / 120.12 2 3
6 13 275.56 18 15.15 697 190 3.03 / 120.31 2 3
7 13 66.24 18 15.20 400 109 3.14 / 120.42 2 2
8 8 0.04 165 15.18 299 749 3.89 / 121.17 2 6
Average= 3.79
(KJ/cycle)

Cycle 30 GMT 21/ 6/2019 20:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 33 15.15 430 215 0.21 / 113.54 2 2
2 12 1179.68 4 15.24 1897 116 0.33 / 113.66 2 2
3 7 2001.20 36 14.85 2798 1496 1.83 / 115.15 2 2
4 13 1471.76 18 14.90 2197 589 2.42 / 115.74 2 3
5 13 947.16 18 14.98 1570 423 2.84 / 116.16 2 3
6 13 415.40 18 15.10 888 241 3.08 / 116.41 2 3
7 13 114.04 18 15.18 469 128 3.21 / 116.53 2 3
8 8 -0.08 165 15.18 299 749 3.96 / 117.28 2 8
Average= 3.78
(KJ/cycle)

Cycle 29 GMT 11/ 6/2019 22:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 33 15.16 444 222 0.22 / 109.68 2 2
2 12 1166.40 4 15.25 1872 114 0.34 / 109.80 2 2
3 7 2003.08 36 14.85 2809 1502 1.84 / 111.30 2 2
4 13 1348.68 18 14.93 2049 551 2.39 / 111.85 2 3
5 13 858.04 18 15.00 1461 394 2.78 / 112.25 2 3
6 13 350.12 18 15.13 795 217 3.00 / 112.46 2 3
7 13 93.92 18 15.19 436 119 3.12 / 112.58 2 2
8 8 0.08 165 15.18 297 744 3.86 / 113.33 2 5
Average= 3.78
(KJ/cycle)

Cycle 28 GMT 1/ 6/2019 23:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 33 15.16 425 213 0.21 / 105.77 2 2
2 12 1163.04 4 15.25 1902 116 0.33 / 105.89 2 2
3 7 2003.56 36 14.85 2809 1502 1.83 / 107.39 2 2
4 13 1480.24 18 14.91 2215 594 2.42 / 107.98 2 3
5 13 952.40 18 14.99 1572 424 2.85 / 108.41 2 3
6 13 288.00 18 15.16 706 193 3.04 / 108.60 2 3
7 13 72.36 18 15.20 410 112 3.15 / 108.71 2 3
8 8 -0.04 165 15.19 299 749 3.90 / 109.46 2 6
Average= 3.77
(KJ/cycle)

Cycle 27 GMT 23/ 5/2019 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 33 15.17 423 212 0.21 / 101.87 2 2
2 12 1153.80 4 15.26 1887 115 0.33 / 101.99 2 2
3 7 2001.40 36 14.85 2803 1498 1.83 / 103.48 2 2
4 13 1477.16 18 14.91 2215 594 2.42 / 104.08 2 3
5 13 949.68 18 14.99 1573 424 2.84 / 104.50 2 4
6 13 283.24 18 15.16 707 193 3.04 / 104.70 2 3
7 13 72.28 18 15.21 409 112 3.15 / 104.81 2 3
8 8 0.00 165 15.19 300 752 3.90 / 105.56 2 6
Average= 3.77
(KJ/cycle)

Cycle 26 GMT 13/ 5/2019 2:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 33 15.17 419 210 0.21 / 97.99 2 2
2 12 1169.00 4 15.25 1896 116 0.33 / 98.11 2 2
3 7 2001.64 36 14.87 2801 1499 1.82 / 99.61 2 2
4 13 1467.80 18 14.92 2193 589 2.41 / 100.20 2 3
5 13 934.00 18 15.00 1556 420 2.83 / 100.62 2 3
6 13 273.92 18 15.17 690 188 3.02 / 100.81 2 3
7 13 69.52 18 15.21 401 110 3.13 / 100.92 2 3
8 8 0.08 165 15.20 296 742 3.87 / 101.66 2 4
Average= 3.77
(KJ/cycle)

Cycle 25 GMT 3/ 5/2019 4:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 33 15.16 430 215 0.22 / 94.12 2 2
2 12 1170.76 3 15.28 1910 88 0.30 / 94.21 2 2
3 7 2002.24 36 14.87 2804 1501 1.80 / 95.71 2 2
4 13 1480.76 18 14.92 2218 596 2.40 / 96.31 2 3
5 13 964.88 18 14.99 1587 428 2.83 / 96.73 2 3
6 13 306.04 18 15.16 729 199 3.03 / 96.93 2 3
7 13 96.20 18 15.21 435 119 3.15 / 97.05 2 3
8 8 0.12 165 15.20 292 732 3.88 / 97.78 2 6
Average= 3.76
(KJ/cycle)

Cycle 24 GMT 23/ 4/2019 5:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 33 15.17 410 205 0.21 / 90.12 2 2
2 12 1169.96 3 15.27 1898 87 0.29 / 90.21 2 2
3 7 2002.56 37 14.87 2805 1543 1.84 / 91.75 2 2
4 13 1488.92 18 14.92 2227 598 2.43 / 92.35 2 3
5 13 962.24 18 15.00 1586 428 2.86 / 92.77 2 3
6 13 444.92 18 15.12 923 251 3.11 / 93.03 2 3
7 13 126.56 18 15.20 486 133 3.25 / 93.16 2 2
8 8 0.16 165 15.19 298 747 3.99 / 93.91 2 5
Average= 3.76
(KJ/cycle)

Cycle 23 GMT 13/ 4/2019 7:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 33 15.18 416 208 0.21 / 86.03 2 2
2 12 1175.60 3 15.29 1901 87 0.30 / 86.12 2 2
3 7 2005.92 36 14.87 2807 1503 1.80 / 87.62 2 2
4 13 1483.24 17 14.92 2217 562 2.36 / 88.18 2 2
5 13 968.56 17 15.00 1592 406 2.77 / 88.59 2 3
6 13 455.76 17 15.12 939 241 3.01 / 88.83 2 3
7 13 144.48 17 15.20 507 131 3.14 / 88.96 2 3
8 13 40.20 17 15.22 359 93 3.23 / 89.05 2 3
9 8 0.08 165 15.20 290 727 3.96 / 89.78 2 6
10 14 0.08 30 15.18 289 132 4.09 / 89.91 3 10
Average= 3.75
(KJ/cycle)

Cycle 22 GMT 3/ 4/2019 9:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 33 15.18 421 211 0.21 / 82.10 2 2
2 12 1174.16 3 15.28 1914 88 0.30 / 82.18 2 2
3 7 2002.44 37 14.88 2802 1543 1.84 / 83.73 2 2
4 13 1483.36 17 14.93 2209 561 2.40 / 84.29 2 2
5 13 983.04 17 15.00 1610 411 2.81 / 84.70 2 3
6 13 333.72 17 15.17 763 197 3.01 / 84.89 2 2
7 13 112.48 17 15.22 452 117 3.13 / 85.01 2 2
8 13 31.28 17 15.23 342 89 3.21 / 85.10 2 3
9 8 0.08 165 15.21 288 723 3.94 / 85.82 2 7
Average= 3.73
(KJ/cycle)

Cycle 21 GMT 24/ 3/2019 11:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 33 15.19 419 210 0.21 / 78.24 2 2
2 12 1182.76 3 15.29 1921 88 0.30 / 78.32 2 2
3 7 2004.36 36 14.88 2804 1502 1.80 / 79.83 2 2
4 13 1347.40 17 14.96 2053 522 2.32 / 80.35 2 3
5 13 870.72 17 15.03 1471 376 2.70 / 80.72 2 3
6 13 381.80 17 15.15 837 216 2.91 / 80.94 2 3
7 13 127.36 17 15.21 479 124 3.04 / 81.06 2 2
8 13 29.68 17 15.23 341 88 3.13 / 81.15 2 3
9 8 0.16 165 15.21 292 733 3.86 / 81.88 2 5
Average= 3.72
(KJ/cycle)

Cycle 20 GMT 14/ 3/2019 13: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 33 15.18 426 213 0.21 / 74.35 2 2
2 12 1177.72 2 15.28 1915 59 0.27 / 74.41 2 2
3 7 2007.20 36 14.89 2807 1505 1.78 / 75.91 2 2
4 13 1496.88 17 14.94 2236 568 2.34 / 76.48 2 3
5 13 984.48 17 15.01 1613 412 2.76 / 76.89 2 3
6 13 349.20 17 15.16 787 203 2.96 / 77.09 2 3
7 13 123.40 17 15.22 471 122 3.08 / 77.22 2 3
8 13 31.32 17 15.24 338 88 3.17 / 77.30 2 2
9 8 0.08 165 15.22 288 723 3.89 / 78.03 2 6
Average= 3.72
(KJ/cycle)

Cycle 19 GMT 4/ 3/2019 14:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 33 15.19 417 209 0.21 / 70.50 2 2
2 12 1164.48 2 15.30 1894 58 0.27 / 70.55 2 2
3 7 2004.04 36 14.89 2807 1505 1.77 / 72.06 2 2
4 13 1357.76 17 14.96 2061 524 2.30 / 72.58 2 3
5 13 1023.00 17 15.00 1657 423 2.72 / 73.01 2 3
6 13 492.88 17 15.12 990 254 2.97 / 73.26 2 3
7 13 150.52 17 15.20 518 134 3.11 / 73.39 2 3
8 8 0.32 165 15.21 295 740 3.85 / 74.13 2 4
Average= 3.71
(KJ/cycle)

Cycle 18 GMT 22/ 2/2019 16:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 33 15.19 422 212 0.21 / 66.41 2 2
2 12 1177.24 2 15.31 1903 58 0.27 / 66.47 2 2
3 7 2005.04 36 14.90 2792 1498 1.77 / 67.97 2 2
4 13 1501.88 17 14.95 2229 567 2.33 / 68.53 2 2
5 13 995.88 17 15.02 1628 416 2.75 / 68.95 2 3
6 13 475.52 17 15.13 962 247 3.00 / 69.20 2 3
7 13 166.84 17 15.21 536 139 3.14 / 69.34 2 3
8 13 47.28 17 15.24 367 95 3.23 / 69.43 2 3
9 8 0.00 165 15.22 289 726 3.96 / 70.16 2 10
10 14 0.00 30 15.20 287 131 4.09 / 70.29 3 8
Average= 3.70
(KJ/cycle)

Cycle 17 GMT 12/ 2/2019 18:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 33 15.19 433 217 0.22 / 62.46 2 2
2 12 1176.68 2 15.30 1915 59 0.28 / 62.52 2 2
3 7 2001.60 37 14.90 2804 1546 1.82 / 64.06 2 2
4 13 1484.40 17 14.94 2225 565 2.39 / 64.63 2 3
5 13 974.24 17 15.02 1608 411 2.80 / 65.04 2 3
6 13 331.08 17 15.18 769 198 3.00 / 65.24 2 3
7 13 97.80 17 15.23 448 116 3.11 / 65.35 2 2
8 13 52.60 17 15.24 378 98 3.21 / 65.45 2 3
9 8 -0.04 165 15.22 298 748 3.96 / 66.20 2 7
Average= 3.68
(KJ/cycle)

Cycle 16 GMT 2/ 2/2019 20:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 33 15.19 427 214 0.21 / 58.49 2 2
2 12 1180.80 2 15.31 1944 60 0.27 / 58.55 2 2
3 7 2003.12 36 14.91 2800 1503 1.78 / 60.05 2 2
4 13 1483.36 17 14.95 2218 564 2.34 / 60.62 2 3
5 13 982.36 17 15.03 1611 412 2.75 / 61.03 2 3
6 13 470.28 17 15.14 959 247 3.00 / 61.28 2 3
7 13 96.80 17 15.24 446 116 3.11 / 61.39 2 2
8 13 54.56 17 15.24 382 99 3.21 / 61.49 2 3
9 8 0.08 165 15.22 299 751 3.96 / 62.24 2 6
Average= 3.66
(KJ/cycle)

Cycle 15 GMT 23/ 1/2019 22:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 33 15.19 447 224 0.22 / 54.54 2 2
2 12 1176.80 2 15.31 1904 58 0.28 / 54.60 2 2
3 7 2004.20 36 14.91 2799 1502 1.78 / 56.10 2 2
4 13 1487.08 17 14.96 2218 564 2.35 / 56.67 2 3
5 13 972.80 17 15.03 1598 408 2.76 / 57.08 2 3
6 13 452.28 17 15.15 937 241 3.00 / 57.32 2 3
7 13 79.36 17 15.24 426 110 3.11 / 57.43 2 3
8 13 21.84 17 15.25 342 89 3.20 / 57.52 2 2
9 8 0.04 165 15.22 303 761 3.96 / 58.28 2 5
Average= 3.64
(KJ/cycle)

Cycle 14 GMT 14/ 1/2019 0:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 33 15.21 444 223 0.22 / 50.57 2 2
2 12 1166.16 2 15.33 1890 58 0.28 / 50.63 2 2
3 7 2003.00 36 14.91 2810 1508 1.79 / 52.13 2 2
4 13 1480.40 17 14.96 2210 562 2.35 / 52.70 2 3
5 13 968.96 17 15.04 1597 408 2.76 / 53.10 2 3
6 13 462.20 17 15.15 953 245 3.00 / 53.35 2 4
7 13 68.80 17 15.25 415 108 3.11 / 53.46 2 2
8 13 18.20 17 15.25 342 89 3.20 / 53.55 2 3
9 8 0.08 165 15.22 308 773 3.97 / 54.32 2 4
Average= 3.62
(KJ/cycle)

Cycle 13 GMT 4/ 1/2019 2:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 33 15.20 456 229 0.23 / 46.75 2 2
2 12 1178.32 2 15.33 1905 58 0.29 / 46.81 2 2
3 7 2005.32 36 14.92 2804 1506 1.79 / 48.31 2 2
4 13 1479.16 17 14.96 2212 563 2.36 / 48.88 2 3
5 13 972.88 17 15.04 1596 408 2.76 / 49.28 2 3
6 13 333.80 17 15.19 773 200 2.96 / 49.48 2 3
7 13 91.16 17 15.25 432 112 3.08 / 49.60 2 3
8 8 0.04 165 15.24 298 749 3.82 / 50.34 2 6
Average= 3.60
(KJ/cycle)

Cycle 12 GMT 25/12/2018 4:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 33 15.20 454 228 0.23 / 42.85 2 2
2 12 1175.92 2 15.33 1934 59 0.29 / 42.91 2 2
3 7 2003.44 36 14.92 2807 1508 1.79 / 44.42 2 2
4 13 1493.00 17 14.97 2229 567 2.36 / 44.99 2 2
5 13 984.76 17 15.04 1616 413 2.78 / 45.40 2 3
6 13 465.96 17 15.15 955 246 3.02 / 45.65 2 3
7 13 72.68 17 15.25 414 107 3.13 / 45.75 2 3
8 8 0.12 165 15.23 305 766 3.89 / 46.52 2 5
Average= 3.58
(KJ/cycle)

Cycle 11 GMT 15/12/2018 6:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 33 15.22 428 215 0.21 / 38.97 2 2
2 12 1160.72 2 15.33 1885 58 0.27 / 39.03 2 2
3 7 2004.92 36 14.92 2805 1507 1.78 / 40.54 2 2
4 13 1344.72 17 14.99 2057 524 2.30 / 41.06 2 3
5 13 1012.32 17 15.03 1646 421 2.72 / 41.48 2 3
6 13 483.64 17 15.14 981 252 2.98 / 41.73 2 4
7 13 73.00 17 15.25 424 110 3.09 / 41.84 2 3
8 8 0.00 165 15.23 311 782 3.87 / 42.63 2 8
Average= 3.55
(KJ/cycle)

Cycle 10 GMT 5/12/2018 8: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 33 15.20 465 233 0.23 / 35.09 2 2
2 12 1191.40 2 15.33 1954 60 0.29 / 35.15 2 2
3 7 2006.84 37 14.93 2808 1551 1.84 / 36.70 2 2
4 13 1499.28 17 14.97 2235 569 2.41 / 37.27 2 3
5 13 1000.12 17 15.04 1632 417 2.83 / 37.69 2 3
6 13 356.68 17 15.19 797 206 3.04 / 37.89 2 3
7 13 105.96 17 15.26 448 116 3.15 / 38.01 2 3
8 8 0.36 165 15.25 298 750 3.90 / 38.76 2 4
Average= 3.52
(KJ/cycle)

Cycle 9 GMT 25/11/2018 9:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 33 15.21 462 232 0.23 / 31.19 2 2
2 12 1181.16 2 15.33 1932 59 0.29 / 31.25 2 2
3 7 2003.24 36 14.93 2808 1509 1.80 / 32.76 2 2
4 13 1464.60 17 14.98 2190 558 2.36 / 33.32 2 3
5 13 955.00 17 15.05 1577 403 2.76 / 33.72 2 3
6 13 439.08 17 15.17 921 238 3.00 / 33.96 2 3
7 13 60.12 17 15.26 405 105 3.10 / 34.07 2 3
8 8 0.00 165 15.24 314 790 3.89 / 34.85 2 8
Average= 3.49
(KJ/cycle)

Cycle 8 GMT 15/11/2018 11:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 32 15.21 439 214 0.21 / 27.25 2 2
2 12 1174.52 2 15.33 1917 59 0.27 / 27.31 2 2
3 7 2003.40 37 14.92 2805 1548 1.82 / 28.86 2 2
4 13 1483.52 17 14.98 2218 565 2.39 / 29.42 2 3
5 13 975.36 17 15.05 1604 410 2.80 / 29.83 2 3
6 13 451.60 17 15.16 942 243 3.04 / 30.07 2 3
7 13 66.04 17 15.26 409 106 3.15 / 30.18 2 2
8 8 0.16 165 15.24 311 782 3.93 / 30.96 2 6
Average= 3.44
(KJ/cycle)

Cycle 7 GMT 5/11/2018 13:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 32 15.21 432 210 0.21 / 23.26 2 2
2 3 1026.08 1 15.26 1740 27 0.24 / 23.28 2 2
3 12 1184.08 2 15.34 1929 59 0.30 / 23.34 2 2
4 7 2003.28 37 14.94 2802 1549 1.84 / 24.89 2 2
5 13 1493.12 16 15.00 2229 535 2.38 / 25.43 2 3
6 13 988.72 16 15.06 1618 390 2.77 / 25.82 2 3
7 13 487.76 16 15.16 979 237 3.01 / 26.06 2 3
8 13 165.52 16 15.25 539 132 3.14 / 26.19 2 2
9 13 38.80 16 15.27 361 88 3.23 / 26.27 2 2
10 8 0.12 165 15.24 302 759 3.99 / 27.03 2 3
Average= 3.38
(KJ/cycle)

Cycle 6 GMT 26/10/2018 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 31 15.22 431 203 0.20 / 19.31 2 2
2 3 1035.72 1 15.25 1760 27 0.23 / 19.33 2 2
3 7 2007.64 36 14.94 2805 1509 1.74 / 20.84 2 2
4 13 1511.56 18 14.98 2239 604 2.34 / 21.44 2 2
5 13 1004.88 18 15.05 1632 442 2.78 / 21.89 2 3
6 13 485.36 18 15.16 974 266 3.05 / 22.15 2 3
7 13 155.00 18 15.24 521 143 3.19 / 22.30 2 3
8 8 0.12 165 15.25 299 752 3.95 / 23.05 2 7
Average= 3.29
(KJ/cycle)

Cycle 5 GMT 16/10/2018 17:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.88 30 15.23 456 208 0.21 / 15.34 2 2
2 3 1026.72 1 15.26 1744 27 0.23 / 15.36 2 2
3 7 2007.40 37 14.95 2810 1554 1.79 / 16.92 2 2
4 13 1502.36 18 15.00 2232 603 2.39 / 17.52 2 2
5 13 1002.24 18 15.05 1628 441 2.83 / 17.96 2 3
6 13 472.48 18 15.16 957 261 3.09 / 18.22 2 3
7 13 79.72 18 15.27 419 115 3.21 / 18.34 2 3
8 8 0.08 165 15.25 304 765 3.97 / 19.10 2 4
Average= 3.18
(KJ/cycle)

Cycle 4 GMT 6/10/2018 17:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.08 30 15.23 451 206 0.21 / 11.94 2 2
2 7 1525.16 38 15.06 2224 1273 1.48 / 13.21 2 2
3 13 1240.92 18 15.07 1910 518 2.00 / 13.73 2 2
4 13 752.80 18 15.13 1314 358 2.35 / 14.09 2 3
5 13 246.40 18 15.24 653 179 2.53 / 14.27 2 3
6 13 60.64 18 15.29 390 107 2.64 / 14.37 2 2
7 8 0.16 165 15.26 300 755 3.40 / 15.13 2 6
Average= 3.03
(KJ/cycle)

Cycle 3 GMT 5/10/2018 17:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 30 15.23 430 196 0.20 / 8.40 2 2
2 3 1030.96 1 15.25 1733 26 0.22 / 8.42 2 2
3 7 1506.12 39 15.06 2207 1296 1.52 / 9.72 2 2
4 13 1350.64 18 15.06 2032 551 2.07 / 10.27 2 2
5 13 830.12 18 15.12 1411 384 2.45 / 10.66 2 3
6 13 295.84 18 15.23 722 198 2.65 / 10.85 2 3
7 13 60.56 18 15.28 399 110 2.76 / 10.96 2 2
8 8 0.00 165 15.26 305 768 3.53 / 11.73 2 5
Average= 2.93
(KJ/cycle)

Cycle 2 GMT 4/10/2018 17:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 29 15.25 451 199 0.20 / 4.94 2 2
2 3 1034.36 1 15.27 1734 26 0.23 / 4.97 2 2
3 7 1506.76 39 15.06 2199 1292 1.52 / 6.26 2 2
4 13 1353.92 18 15.07 2032 551 2.07 / 6.81 2 2
5 13 819.56 18 15.12 1400 381 2.45 / 7.19 2 3
6 13 177.48 18 15.27 557 153 2.60 / 7.34 2 2
7 13 40.60 18 15.30 365 101 2.70 / 7.44 2 3
8 8 0.00 165 15.27 301 758 3.46 / 8.20 2 4
Average= 2.73
(KJ/cycle)

Cycle 1 GMT 3/10/2018 17:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 28 15.43 414 179 0.18 / 1.77 2 2
2 10 1011.68 2 15.28 1658 51 0.23 / 1.82 2 2
3 7 1002.36 74 15.14 1584 1775 2.00 / 3.59 2 3
4 8 0.00 240 15.30 312 1146 3.15 / 4.74 2 13
Average= 2.37
(KJ/cycle)

Cycle 0 GMT 3/10/2018 7: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 129.84 22 15.58 442 151 0.15 / 0.15 2 2
2 7 144.56 74 15.55 442 509 0.66 / 0.66 2 2
3 8 0.32 240 15.50 250 930 1.59 / 1.59 2 11
Average= 1.59
(KJ/cycle)