SIO Argo Site:
Pump Diagnostics Page   



Serial= 8664 WMO= 5905687

Return

←PreviousNext→

Cycle 212 GMT 16/ 4/2024 14:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 35 14.84 476 247 0.25 / 897.82 3 3
2 12 1192.12 3 15.05 1954 88 0.34 / 897.91 3 3
3 7 2002.84 30 14.68 2858 1259 1.59 / 899.17 3 3
4 13 1678.56 24 14.63 2503 879 2.47 / 900.05 3 3
5 13 969.96 24 14.69 1647 581 3.05 / 900.63 3 4
6 13 288.76 24 14.83 776 276 3.33 / 900.91 3 4
7 13 53.36 24 14.90 433 155 3.48 / 901.06 3 3
8 8 0.16 165 14.87 348 854 4.34 / 901.91 3 7
Average= 4.23
(KJ/cycle)

Cycle 211 GMT 6/ 4/2024 16:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 35 14.84 486 252 0.25 / 893.52 3 3
2 12 1180.36 3 15.04 1941 88 0.34 / 893.61 3 3
3 7 2005.48 30 14.68 2847 1254 1.59 / 894.86 3 3
4 13 1693.56 24 14.62 2520 884 2.48 / 895.74 3 3
5 13 972.32 24 14.68 1653 582 3.06 / 896.33 3 4
6 13 286.28 24 14.83 771 274 3.33 / 896.60 3 5
7 13 37.52 24 14.90 397 142 3.48 / 896.74 3 3
8 8 0.08 165 14.87 340 834 4.31 / 897.58 3 10
Average= 4.23
(KJ/cycle)

Cycle 210 GMT 27/ 3/2024 19:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 35 14.84 470 244 0.24 / 889.16 3 3
2 12 1177.64 3 15.06 1939 88 0.33 / 889.25 3 3
3 7 2008.64 30 14.67 2852 1255 1.59 / 890.50 3 3
4 13 1705.64 24 14.62 2524 886 2.47 / 891.39 3 4
5 13 1004.48 24 14.67 1685 593 3.07 / 891.98 3 4
6 13 307.76 24 14.83 797 284 3.35 / 892.27 3 4
7 13 58.84 24 14.89 437 156 3.51 / 892.42 3 3
8 8 -0.04 165 14.87 344 844 4.35 / 893.27 3 6
Average= 4.23
(KJ/cycle)

Cycle 209 GMT 17/ 3/2024 21:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 35 14.84 460 239 0.24 / 884.76 3 3
2 12 1177.56 3 15.06 1956 88 0.33 / 884.85 3 3
3 7 2002.64 31 14.68 2853 1298 1.63 / 886.15 3 4
4 13 1713.52 24 14.62 2556 897 2.52 / 887.05 3 4
5 13 988.68 24 14.68 1677 591 3.11 / 887.64 3 4
6 13 298.92 24 14.83 786 280 3.39 / 887.92 3 5
7 13 37.84 24 14.90 407 146 3.54 / 888.06 3 3
8 8 0.16 165 14.87 347 851 4.39 / 888.92 3 6
Average= 4.23
(KJ/cycle)

Cycle 208 GMT 7/ 3/2024 23:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 35 14.84 473 246 0.25 / 880.42 3 3
2 12 1170.04 3 15.05 1921 87 0.33 / 880.51 3 3
3 7 2005.96 30 14.68 2838 1250 1.58 / 881.76 3 4
4 13 1850.16 24 14.60 2702 947 2.53 / 882.71 3 4
5 13 957.64 24 14.69 1633 576 3.10 / 883.28 3 4
6 13 289.96 24 14.83 774 275 3.38 / 883.56 3 4
7 13 55.08 24 14.90 417 149 3.53 / 883.71 3 3
8 8 0.04 165 14.87 334 819 4.35 / 884.53 3 9
Average= 4.23
(KJ/cycle)

Cycle 207 GMT 27/ 2/2024 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 35 14.84 455 236 0.24 / 876.15 3 3
2 12 1198.08 3 15.04 1977 89 0.33 / 876.24 3 3
3 7 2011.60 30 14.67 2862 1260 1.59 / 877.50 3 3
4 13 1560.24 24 14.64 2353 827 2.41 / 878.33 3 5
5 13 878.84 24 14.70 1537 542 2.95 / 878.87 3 4
6 13 341.52 24 14.81 852 303 3.26 / 879.17 3 4
7 13 43.04 24 14.89 422 151 3.41 / 879.32 3 3
8 8 0.16 165 14.86 349 856 4.26 / 880.18 3 7
Average= 4.23
(KJ/cycle)

Cycle 206 GMT 17/ 2/2024 4:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 35 14.85 469 244 0.24 / 871.84 3 3
2 12 1171.88 3 15.06 1945 88 0.33 / 871.93 3 3
3 7 2008.56 30 14.68 2845 1253 1.58 / 873.18 3 4
4 13 1695.52 24 14.63 2518 884 2.47 / 874.07 3 4
5 13 990.76 24 14.68 1676 590 3.06 / 874.66 3 4
6 13 300.72 24 14.83 790 281 3.34 / 874.94 3 4
7 13 36.08 24 14.90 399 143 3.48 / 875.08 3 3
8 8 0.12 165 14.87 339 832 4.31 / 875.91 3 5
Average= 4.23
(KJ/cycle)

Cycle 205 GMT 7/ 2/2024 6:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 35 14.84 466 242 0.24 / 867.50 3 3
2 12 1182.96 3 15.04 1939 87 0.33 / 867.58 3 3
3 7 2003.44 30 14.67 2857 1257 1.59 / 868.84 3 4
4 13 1680.04 24 14.63 2506 880 2.47 / 869.72 3 4
5 13 988.28 24 14.67 1673 589 3.06 / 870.31 3 4
6 13 306.96 24 14.82 805 286 3.34 / 870.60 3 4
7 13 58.28 24 14.89 435 155 3.50 / 870.75 3 3
8 8 0.08 165 14.87 345 846 4.34 / 871.60 3 5
Average= 4.23
(KJ/cycle)

Cycle 204 GMT 28/ 1/2024 8:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 35 14.83 491 255 0.25 / 862.99 3 3
2 12 1167.76 3 15.05 1933 87 0.34 / 863.08 3 3
3 7 2010.92 30 14.68 2880 1268 1.61 / 864.34 3 4
4 13 1868.12 24 14.60 2714 951 2.56 / 865.29 3 4
5 13 1113.00 24 14.66 1821 641 3.20 / 865.94 3 4
6 13 378.92 24 14.80 901 320 3.52 / 866.26 3 4
7 13 47.92 24 14.90 421 151 3.67 / 866.41 3 3
8 8 0.04 165 14.87 346 849 4.52 / 867.25 3 6
Average= 4.23
(KJ/cycle)

Cycle 203 GMT 18/ 1/2024 11: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 35 14.83 465 241 0.24 / 858.51 3 3
2 12 1159.12 3 15.06 1924 87 0.33 / 858.60 3 3
3 7 2004.24 30 14.68 2861 1260 1.59 / 859.86 3 4
4 13 1700.00 24 14.62 2516 883 2.47 / 860.74 3 3
5 13 1142.20 24 14.65 1857 653 3.12 / 861.40 3 4
6 13 377.68 24 14.80 906 322 3.45 / 861.72 3 4
7 13 45.52 24 14.90 424 152 3.60 / 861.87 3 4
8 8 0.08 165 14.87 352 864 4.46 / 862.73 3 5
Average= 4.23
(KJ/cycle)

Cycle 202 GMT 8/ 1/2024 13:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 35 14.85 463 241 0.24 / 854.18 3 3
2 12 1173.72 3 15.04 1935 87 0.33 / 854.27 3 3
3 7 1960.24 30 14.67 2806 1235 1.56 / 855.50 3 3
4 13 1649.84 24 14.63 2470 867 2.43 / 856.37 3 4
5 13 937.12 24 14.69 1608 567 3.00 / 856.93 3 4
6 13 388.96 24 14.80 914 325 3.32 / 857.26 3 5
7 13 40.12 24 14.90 417 149 3.47 / 857.41 3 3
8 8 0.00 165 14.86 352 863 4.33 / 858.27 3 8
Average= 4.23
(KJ/cycle)

Cycle 201 GMT 29/12/2023 13: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 35 14.85 472 245 0.25 / 849.86 3 3
2 12 1186.84 3 15.05 1926 87 0.33 / 849.94 3 3
3 7 1990.04 31 14.66 2859 1299 1.63 / 851.24 3 3
4 13 1673.12 24 14.63 2499 877 2.51 / 852.12 3 4
5 13 964.56 24 14.68 1644 579 3.09 / 852.70 3 4
6 13 279.56 24 14.83 753 268 3.36 / 852.97 3 5
7 13 26.48 24 14.90 382 137 3.49 / 853.10 3 3
8 8 0.12 165 14.87 340 834 4.33 / 853.94 3 8
Average= 4.23
(KJ/cycle)

Cycle 200 GMT 19/12/2023 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 35 14.86 464 241 0.24 / 845.63 3 3
2 12 1174.24 3 15.04 1930 87 0.33 / 845.72 3 3
3 7 1830.76 30 14.72 2663 1176 1.50 / 846.89 3 4
4 13 1676.72 24 14.65 2500 879 2.38 / 847.77 3 4
5 13 978.28 24 14.70 1661 586 2.97 / 848.36 3 4
6 13 284.24 24 14.84 767 273 3.24 / 848.63 3 4
7 13 29.32 24 14.91 388 139 3.38 / 848.77 3 3
8 8 0.12 165 14.88 343 842 4.22 / 849.61 3 5
Average= 4.23
(KJ/cycle)

Cycle 199 GMT 9/12/2023 12:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 35 14.85 482 251 0.25 / 841.61 3 3
2 12 1160.08 3 15.06 1925 87 0.34 / 841.70 3 3
3 7 1624.44 30 14.80 2386 1059 1.40 / 842.76 3 3
4 13 1494.40 24 14.73 2274 804 2.20 / 843.56 3 4
5 13 970.84 24 14.75 1645 582 2.78 / 844.15 3 4
6 13 251.44 24 14.88 711 254 3.04 / 844.40 3 4
7 13 44.80 24 14.92 412 148 3.18 / 844.55 3 3
8 8 0.04 165 14.89 342 840 4.02 / 845.39 3 6
Average= 4.23
(KJ/cycle)

Cycle 198 GMT 29/11/2023 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 35 14.84 484 251 0.25 / 837.37 3 3
2 12 1332.44 3 15.01 2144 97 0.35 / 837.47 3 3
3 7 1835.48 30 14.71 2659 1173 1.52 / 838.64 3 4
4 13 1681.52 24 14.65 2504 880 2.40 / 839.53 3 4
5 13 968.76 24 14.71 1647 581 2.98 / 840.11 3 4
6 13 280.04 24 14.85 756 269 3.25 / 840.38 3 4
7 13 24.60 24 14.92 382 137 3.39 / 840.51 3 3
8 8 0.04 165 14.88 346 849 4.24 / 841.36 3 7
Average= 4.23
(KJ/cycle)

Cycle 197 GMT 19/11/2023 12:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 35 14.85 490 255 0.25 / 833.20 3 3
2 12 1171.80 3 15.05 1922 87 0.34 / 833.29 3 3
3 7 1744.64 30 14.74 2537 1122 1.46 / 834.41 3 3
4 13 1596.96 24 14.68 2397 845 2.31 / 835.26 3 3
5 13 893.40 24 14.74 1557 551 2.86 / 835.81 3 4
6 13 347.68 24 14.84 856 305 3.16 / 836.11 3 5
7 13 32.92 24 14.92 402 144 3.31 / 836.26 3 3
8 8 0.08 165 14.88 353 867 4.17 / 837.12 3 6
Average= 4.23
(KJ/cycle)

Cycle 196 GMT 9/11/2023 12:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 35 14.87 473 246 0.25 / 829.14 3 3
2 12 1185.64 3 15.04 1929 87 0.33 / 829.23 3 3
3 7 1640.64 30 14.78 2445 1084 1.42 / 830.31 3 4
4 13 1515.28 24 14.71 2309 815 2.23 / 831.13 3 4
5 13 851.40 24 14.76 1496 530 2.76 / 831.66 3 4
6 13 314.92 24 14.85 815 290 3.05 / 831.95 3 5
7 13 26.36 24 14.92 390 140 3.19 / 832.09 3 3
8 8 0.00 165 14.89 350 860 4.05 / 832.95 3 6
Average= 4.23
(KJ/cycle)

Cycle 195 GMT 30/10/2023 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 35 14.88 480 250 0.25 / 825.32 3 3
2 12 1165.00 3 15.05 1922 87 0.34 / 825.41 3 3
3 7 1522.32 30 14.82 2290 1018 1.35 / 826.43 3 3
4 13 1398.96 24 14.76 2162 766 2.12 / 827.19 3 4
5 13 893.96 24 14.78 1545 548 2.67 / 827.74 3 4
6 13 339.36 24 14.86 849 303 2.97 / 828.05 3 4
7 8 0.16 165 14.91 346 851 3.82 / 828.90 3 5
Average= 4.23
(KJ/cycle)

Cycle 194 GMT 20/10/2023 12:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 35 14.86 508 264 0.26 / 821.70 3 3
2 12 1183.84 3 15.05 1944 88 0.35 / 821.79 3 3
3 7 1380.52 30 14.87 2125 948 1.30 / 822.74 3 3
4 13 1282.24 24 14.81 2026 720 2.02 / 823.46 3 3
5 13 778.32 24 14.83 1411 502 2.52 / 823.96 3 4
6 13 244.48 24 14.91 706 253 2.77 / 824.21 3 4
7 8 0.16 165 14.92 350 862 3.64 / 825.07 3 9
Average= 4.23
(KJ/cycle)

Cycle 193 GMT 10/10/2023 13: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 35 14.86 487 253 0.25 / 817.66 3 3
2 12 1168.60 3 15.05 1921 87 0.34 / 817.74 3 3
3 7 1728.20 30 14.76 2541 1125 1.47 / 818.87 3 3
4 13 1585.80 24 14.69 2389 842 2.31 / 819.71 3 4
5 13 920.56 24 14.74 1591 563 2.87 / 820.27 3 4
6 13 378.52 24 14.82 900 320 3.19 / 820.59 3 4
7 8 0.12 165 14.90 343 843 4.03 / 821.44 3 8
Average= 4.23
(KJ/cycle)

Cycle 192 GMT 30/ 9/2023 13: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 35 14.87 479 249 0.25 / 813.70 3 3
2 12 1170.92 3 15.04 1926 87 0.34 / 813.78 3 3
3 7 1648.28 30 14.78 2446 1085 1.42 / 814.87 3 4
4 13 1523.20 24 14.71 2316 818 2.24 / 815.69 3 4
5 13 998.00 24 14.74 1683 595 2.83 / 816.28 3 4
6 13 273.96 24 14.87 756 270 3.10 / 816.55 3 4
7 8 0.20 165 14.90 347 853 3.96 / 817.40 3 6
Average= 4.24
(KJ/cycle)

Cycle 191 GMT 20/ 9/2023 13:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 35 14.88 472 246 0.25 / 809.79 3 3
2 12 1178.96 3 15.05 1941 88 0.33 / 809.88 3 3
3 7 1450.28 30 14.85 2205 982 1.32 / 810.86 3 3
4 13 1341.84 24 14.79 2093 743 2.06 / 811.60 3 3
5 13 1013.00 24 14.78 1691 600 2.66 / 812.20 3 4
6 13 270.48 24 14.90 746 267 2.93 / 812.47 3 4
7 13 24.20 24 14.95 383 137 3.06 / 812.61 3 3
8 8 0.08 165 14.91 342 841 3.90 / 813.45 3 5
Average= 4.24
(KJ/cycle)

Cycle 190 GMT 10/ 9/2023 13:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 35 14.84 480 249 0.25 / 806.02 3 3
2 12 1173.24 3 15.05 1935 87 0.34 / 806.11 3 3
3 7 1493.64 30 14.84 2234 995 1.33 / 807.10 3 3
4 13 1409.80 24 14.78 2129 755 2.09 / 807.86 3 4
5 13 892.20 24 14.80 1532 544 2.63 / 808.40 3 4
6 13 335.64 24 14.87 839 299 2.93 / 808.70 3 4
7 8 0.12 165 14.92 342 842 3.77 / 809.54 3 10
Average= 4.24
(KJ/cycle)

Cycle 189 GMT 31/ 8/2023 13:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.24 35 14.85 494 257 0.26 / 801.64 3 3
2 12 1155.56 3 15.06 1929 87 0.34 / 801.73 3 3
3 7 1927.48 30 14.70 2763 1218 1.56 / 802.95 3 4
4 13 1636.96 24 14.65 2452 862 2.42 / 803.81 3 5
5 13 1108.60 24 14.67 1825 643 3.07 / 804.45 3 4
6 13 374.56 24 14.81 897 319 3.39 / 804.77 3 4
7 13 42.60 24 14.91 411 147 3.53 / 804.92 3 3
8 8 0.00 165 14.87 348 854 4.39 / 805.77 3 6
Average= 4.24
(KJ/cycle)

Cycle 188 GMT 21/ 8/2023 13:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 34 14.86 473 239 0.24 / 797.49 3 3
2 12 1190.88 3 15.06 1943 88 0.33 / 797.58 3 3
3 7 1770.76 30 14.75 2574 1139 1.47 / 798.72 3 3
4 13 1620.20 24 14.68 2426 855 2.32 / 799.58 3 4
5 13 926.60 24 14.73 1599 565 2.89 / 800.14 3 4
6 13 253.44 24 14.87 723 258 3.14 / 800.40 3 4
7 13 23.56 24 14.93 378 135 3.28 / 800.53 3 3
8 8 -0.04 165 14.88 346 849 4.13 / 801.38 3 6
Average= 4.24
(KJ/cycle)

Cycle 187 GMT 11/ 8/2023 13:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.48 34 14.86 495 250 0.25 / 793.48 3 3
2 12 1178.88 3 15.06 1924 87 0.34 / 793.57 3 3
3 7 1908.80 30 14.70 2733 1205 1.54 / 794.78 3 4
4 13 1604.88 24 14.66 2417 850 2.39 / 795.63 3 4
5 13 881.36 24 14.73 1543 545 2.94 / 796.17 3 4
6 13 225.88 24 14.87 680 243 3.18 / 796.41 3 4
7 8 0.12 165 14.90 342 841 4.02 / 797.26 3 7
Average= 4.24
(KJ/cycle)

Cycle 186 GMT 1/ 8/2023 12:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 35 14.87 465 242 0.24 / 789.20 3 3
2 12 1158.96 3 15.05 1911 86 0.33 / 789.28 3 3
3 7 1959.32 31 14.68 2800 1274 1.60 / 790.56 3 3
4 13 1659.24 24 14.63 2493 875 2.48 / 791.43 3 4
5 13 973.76 24 14.69 1654 583 3.06 / 792.01 3 4
6 13 293.04 24 14.83 774 275 3.34 / 792.29 3 4
7 8 0.16 165 14.89 333 818 4.15 / 793.11 3 7
8 14 0.16 25 14.86 339 126 4.28 / 793.23 3 7
Average= 4.24
(KJ/cycle)

Cycle 185 GMT 22/ 7/2023 12: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 35 14.85 483 251 0.25 / 785.28 3 3
2 12 1168.04 3 15.06 1929 87 0.34 / 785.36 3 3
3 7 1598.24 31 14.81 2381 1093 1.43 / 786.46 3 3
4 13 1489.48 24 14.74 2281 807 2.24 / 787.26 3 3
5 13 970.96 24 14.76 1651 585 2.82 / 787.85 3 4
6 13 267.12 24 14.88 748 267 3.09 / 788.11 3 4
7 8 0.12 165 14.91 341 839 3.93 / 788.95 3 4
Average= 4.24
(KJ/cycle)

Cycle 184 GMT 12/ 7/2023 12:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 35 14.86 474 247 0.25 / 780.83 3 3
2 12 1161.72 3 15.06 1909 86 0.33 / 780.92 3 3
3 7 2012.60 30 14.69 2874 1267 1.60 / 782.18 3 3
4 13 1719.76 24 14.64 2548 895 2.49 / 783.08 3 4
5 13 1158.36 24 14.66 1882 662 3.16 / 783.74 3 4
6 13 296.84 24 14.84 777 277 3.43 / 784.02 3 4
7 13 59.12 24 14.90 433 155 3.59 / 784.17 3 3
8 8 0.16 165 14.88 347 852 4.44 / 785.02 3 9
Average= 4.24
(KJ/cycle)

Cycle 183 GMT 2/ 7/2023 14:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 35 14.84 482 250 0.25 / 776.41 3 3
2 12 1176.72 3 15.06 1947 88 0.34 / 776.50 3 3
3 7 2010.64 30 14.69 2856 1259 1.60 / 777.76 3 3
4 13 1691.36 24 14.64 2515 884 2.48 / 778.64 3 5
5 13 960.96 24 14.70 1632 576 3.06 / 779.22 3 4
6 13 283.08 24 14.85 771 275 3.33 / 779.49 3 4
7 13 31.72 24 14.92 392 140 3.47 / 779.64 3 3
8 8 0.20 165 14.89 335 823 4.29 / 780.46 3 12
9 14 0.20 25 14.86 339 126 4.42 / 780.58 3 8
Average= 4.24
(KJ/cycle)

Cycle 182 GMT 22/ 6/2023 16:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 35 14.85 465 242 0.24 / 771.88 3 3
2 12 1165.92 3 15.06 1934 87 0.33 / 771.96 3 3
3 7 2004.36 30 14.70 2845 1255 1.58 / 773.22 3 3
4 13 1848.44 24 14.62 2699 947 2.53 / 774.16 3 4
5 13 1134.76 24 14.67 1855 653 3.18 / 774.82 3 4
6 13 400.52 24 14.80 931 331 3.51 / 775.15 3 4
7 13 49.12 24 14.91 423 151 3.67 / 775.30 3 4
8 8 0.04 165 14.87 352 864 4.53 / 776.16 3 5
Average= 4.24
(KJ/cycle)

Cycle 181 GMT 12/ 6/2023 19: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 35 14.85 451 234 0.23 / 767.49 3 3
2 12 1181.48 3 15.06 1931 87 0.32 / 767.58 3 3
3 7 2011.60 30 14.69 2870 1265 1.59 / 768.85 3 4
4 13 1714.68 24 14.63 2547 894 2.48 / 769.74 3 4
5 13 1010.80 24 14.68 1702 600 3.08 / 770.34 3 4
6 13 304.20 24 14.83 796 283 3.36 / 770.62 3 4
7 13 58.32 24 14.90 441 158 3.52 / 770.78 3 3
8 8 0.24 165 14.87 348 854 4.38 / 771.63 3 5
Average= 4.24
(KJ/cycle)

Cycle 180 GMT 2/ 6/2023 21: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 35 14.85 459 239 0.24 / 763.20 3 3
2 12 1169.00 3 15.06 1928 87 0.33 / 763.29 3 3
3 7 2004.56 30 14.69 2856 1259 1.58 / 764.55 3 4
4 13 1543.76 24 14.66 2344 825 2.41 / 765.37 3 4
5 13 1039.08 24 14.68 1731 610 3.02 / 765.98 3 4
6 13 301.52 24 14.83 798 284 3.30 / 766.26 3 5
7 13 54.28 24 14.90 435 156 3.46 / 766.42 3 4
8 8 0.08 165 14.87 342 839 4.30 / 767.26 3 8
Average= 4.24
(KJ/cycle)

Cycle 179 GMT 23/ 5/2023 23:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 35 14.85 468 243 0.24 / 758.92 3 3
2 12 1181.16 3 15.07 1967 89 0.33 / 759.01 3 3
3 7 2005.56 31 14.70 2847 1297 1.63 / 760.31 3 3
4 13 1549.76 24 14.66 2343 824 2.45 / 761.13 3 4
5 13 893.16 24 14.71 1553 548 3.00 / 761.68 3 4
6 13 365.20 24 14.81 871 310 3.31 / 761.99 3 4
7 13 31.16 24 14.91 391 140 3.45 / 762.13 3 3
8 8 0.12 165 14.88 338 830 4.28 / 762.96 3 7
Average= 4.24
(KJ/cycle)

Cycle 178 GMT 14/ 5/2023 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 34 14.86 467 236 0.24 / 754.62 3 3
2 12 1166.08 3 15.06 1946 88 0.32 / 754.71 3 3
3 7 2009.48 30 14.70 2850 1257 1.58 / 755.97 3 4
4 13 1694.24 24 14.65 2488 875 2.46 / 756.84 3 4
5 13 995.44 24 14.70 1678 592 3.05 / 757.43 3 4
6 13 301.52 24 14.84 798 284 3.33 / 757.72 3 4
7 13 33.64 24 14.91 387 138 3.47 / 757.85 3 3
8 8 0.04 165 14.88 336 825 4.30 / 758.68 3 6
Average= 4.24
(KJ/cycle)

Cycle 177 GMT 4/ 5/2023 3:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 34 14.86 460 232 0.23 / 750.31 3 3
2 12 1171.64 3 15.07 1935 87 0.32 / 750.39 3 3
3 7 2010.20 30 14.71 2851 1258 1.58 / 751.65 3 4
4 13 1688.76 24 14.65 2507 881 2.46 / 752.53 3 4
5 13 987.32 24 14.70 1662 586 3.05 / 753.12 3 4
6 13 296.32 24 14.85 778 277 3.32 / 753.40 3 4
7 13 54.04 24 14.91 422 151 3.47 / 753.55 3 3
8 8 0.00 165 14.88 341 837 4.31 / 754.38 3 6
Average= 4.24
(KJ/cycle)

Cycle 176 GMT 24/ 4/2023 6: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 34 14.87 454 230 0.23 / 745.97 3 3
2 12 1169.32 3 15.07 1912 86 0.32 / 746.06 3 3
3 7 2004.36 30 14.70 2854 1259 1.57 / 747.32 3 3
4 13 1708.72 24 14.65 2528 889 2.46 / 748.21 3 4
5 13 1004.52 24 14.70 1687 595 3.06 / 748.80 3 4
6 13 317.64 24 14.84 807 287 3.35 / 749.09 3 4
7 13 35.72 24 14.92 400 143 3.49 / 749.23 3 3
8 8 0.08 165 14.88 343 842 4.33 / 750.07 3 5
Average= 4.24
(KJ/cycle)

Cycle 175 GMT 14/ 4/2023 7:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 34 14.86 457 231 0.23 / 741.83 3 3
2 12 1166.56 3 15.08 1945 88 0.32 / 741.92 3 3
3 7 2003.32 30 14.70 2843 1254 1.57 / 743.17 3 4
4 13 1524.84 24 14.67 2321 817 2.39 / 743.99 3 4
5 13 896.24 24 14.72 1559 551 2.94 / 744.54 3 4
6 13 222.12 24 14.87 678 242 3.18 / 744.78 3 4
7 13 47.24 24 14.92 417 149 3.33 / 744.93 3 3
8 8 0.16 165 14.89 330 811 4.14 / 745.74 3 8
Average= 4.24
(KJ/cycle)

Cycle 174 GMT 4/ 4/2023 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 34 14.85 464 234 0.23 / 737.51 3 3
2 12 1183.16 3 15.07 1950 88 0.32 / 737.59 3 3
3 7 2003.76 31 14.70 2845 1296 1.62 / 738.89 3 3
4 13 1684.08 24 14.65 2517 885 2.50 / 739.78 3 4
5 13 963.80 24 14.71 1641 579 3.08 / 740.35 3 4
6 13 267.08 24 14.86 738 263 3.35 / 740.62 3 4
7 13 51.60 24 14.92 428 153 3.50 / 740.77 3 4
8 8 0.20 165 14.89 337 828 4.33 / 741.60 3 7
Average= 4.24
(KJ/cycle)

Cycle 173 GMT 25/ 3/2023 12:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 34 14.86 454 229 0.23 / 733.02 3 3
2 12 1165.48 3 15.07 1927 87 0.32 / 733.11 3 3
3 7 2007.20 31 14.70 2855 1301 1.62 / 734.41 3 3
4 13 1852.12 24 14.64 2694 947 2.56 / 735.36 3 4
5 13 1103.16 24 14.69 1796 633 3.20 / 735.99 3 4
6 13 360.16 24 14.82 886 315 3.51 / 736.31 3 4
7 13 43.32 24 14.91 403 144 3.66 / 736.45 3 4
8 8 0.00 165 14.88 334 820 4.48 / 737.27 3 7
Average= 4.24
(KJ/cycle)

Cycle 172 GMT 15/ 3/2023 14:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.28 34 14.86 491 248 0.25 / 728.86 3 3
2 12 1172.76 3 15.06 1924 87 0.33 / 728.94 3 3
3 7 2008.12 30 14.70 2867 1264 1.60 / 730.21 3 3
4 13 1557.72 24 14.67 2365 833 2.43 / 731.04 3 4
5 13 911.88 24 14.71 1575 556 2.99 / 731.60 3 4
6 13 253.36 24 14.86 712 254 3.24 / 731.85 3 4
7 13 53.68 24 14.91 414 148 3.39 / 732.00 3 3
8 8 0.16 165 14.89 324 796 4.19 / 732.79 3 5
Average= 4.24
(KJ/cycle)

Cycle 171 GMT 5/ 3/2023 16:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 34 14.85 508 256 0.26 / 724.52 3 3
2 12 1173.88 3 15.06 1930 87 0.34 / 724.61 3 3
3 7 2009.12 30 14.70 2859 1261 1.60 / 725.87 3 3
4 13 1687.76 24 14.65 2515 884 2.49 / 726.75 3 3
5 13 969.44 24 14.70 1652 583 3.07 / 727.33 3 4
6 13 288.80 24 14.85 772 275 3.35 / 727.61 3 4
7 13 55.60 24 14.91 432 155 3.50 / 727.76 3 3
8 8 0.12 165 14.88 344 845 4.35 / 728.61 3 7
Average= 4.24
(KJ/cycle)

Cycle 170 GMT 23/ 2/2023 18:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 34 14.86 475 240 0.24 / 720.02 3 3
2 12 1171.12 3 15.07 1918 87 0.33 / 720.11 3 3
3 7 2003.28 30 14.71 2858 1261 1.59 / 721.37 3 4
4 13 1700.08 24 14.65 2530 890 2.48 / 722.26 3 5
5 13 1156.16 24 14.68 1862 656 3.13 / 722.91 3 4
6 13 412.48 24 14.81 944 336 3.47 / 723.25 3 4
7 13 41.64 24 14.92 415 149 3.62 / 723.40 3 4
8 8 0.00 165 14.88 353 867 4.48 / 724.26 3 6
Average= 4.24
(KJ/cycle)

Cycle 169 GMT 13/ 2/2023 21: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 34 14.86 471 238 0.24 / 715.67 3 3
2 12 1165.68 3 15.07 1927 87 0.33 / 715.76 3 3
3 7 2005.68 30 14.70 2862 1262 1.59 / 717.02 3 4
4 13 1699.24 24 14.65 2518 885 2.47 / 717.91 3 5
5 13 982.80 24 14.70 1666 588 3.06 / 718.50 3 4
6 13 293.96 24 14.85 773 275 3.34 / 718.77 3 4
7 13 27.08 24 14.92 395 141 3.48 / 718.91 3 3
8 8 0.08 165 14.89 352 865 4.34 / 719.78 3 7
Average= 4.23
(KJ/cycle)

Cycle 168 GMT 3/ 2/2023 23: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 34 14.86 460 232 0.23 / 711.30 3 3
2 12 1187.24 3 15.06 1948 88 0.32 / 711.39 3 3
3 7 2008.32 31 14.70 2858 1302 1.62 / 712.69 3 3
4 13 1709.96 24 14.64 2543 894 2.52 / 713.59 3 4
5 13 986.52 24 14.71 1673 591 3.11 / 714.18 3 4
6 13 290.40 24 14.85 782 279 3.39 / 714.46 3 4
7 13 27.44 24 14.93 396 142 3.53 / 714.60 3 3
8 8 0.08 165 14.89 341 838 4.37 / 715.44 3 8
Average= 4.23
(KJ/cycle)

Cycle 167 GMT 25/ 1/2023 1:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 34 14.85 478 241 0.24 / 706.88 3 3
2 12 1175.72 3 15.07 1944 88 0.33 / 706.96 3 3
3 7 2012.24 30 14.71 2861 1263 1.59 / 708.23 3 3
4 13 1701.76 24 14.65 2534 891 2.48 / 709.12 3 4
5 13 1015.44 24 14.70 1706 602 3.08 / 709.72 3 4
6 13 457.04 24 14.80 1003 356 3.44 / 710.08 3 4
7 13 46.32 24 14.91 422 151 3.59 / 710.23 3 4
8 8 0.12 165 14.88 344 845 4.44 / 711.07 3 5
Average= 4.23
(KJ/cycle)

Cycle 166 GMT 15/ 1/2023 3:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 34 14.86 466 235 0.24 / 702.45 3 3
2 12 1181.96 3 15.06 1951 88 0.32 / 702.54 3 3
3 7 2010.88 30 14.71 2870 1267 1.59 / 703.81 3 3
4 13 1694.52 24 14.66 2517 886 2.48 / 704.69 3 3
5 13 983.16 24 14.71 1656 585 3.06 / 705.28 3 4
6 13 431.32 24 14.81 973 346 3.41 / 705.62 3 4
7 13 46.76 24 14.92 423 151 3.56 / 705.77 3 4
8 8 0.04 165 14.89 350 860 4.42 / 706.63 3 7
Average= 4.23
(KJ/cycle)

Cycle 165 GMT 5/ 1/2023 5:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 34 14.87 470 238 0.24 / 698.18 3 3
2 12 1170.28 3 15.07 1925 87 0.32 / 698.27 3 3
3 7 2007.52 30 14.70 2862 1262 1.59 / 699.53 3 3
4 13 1536.36 24 14.67 2338 823 2.41 / 700.36 3 4
5 13 895.20 24 14.72 1559 551 2.96 / 700.91 3 4
6 13 354.12 24 14.83 868 309 3.27 / 701.22 3 5
7 13 25.08 24 14.92 389 139 3.41 / 701.36 3 3
8 8 0.08 165 14.88 351 862 4.27 / 702.22 3 6
Average= 4.23
(KJ/cycle)

Cycle 164 GMT 26/12/2022 7:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 34 14.86 490 248 0.25 / 694.04 3 3
2 12 1180.48 3 15.07 1948 88 0.34 / 694.13 3 3
3 7 2007.80 31 14.70 2859 1303 1.64 / 695.43 3 4
4 13 1535.00 24 14.67 2328 820 2.46 / 696.25 3 4
5 13 856.16 24 14.74 1512 535 2.99 / 696.78 3 4
6 13 339.48 24 14.83 853 304 3.30 / 697.09 3 5
7 8 0.28 165 14.90 349 858 4.15 / 697.95 3 6
Average= 4.23
(KJ/cycle)

Cycle 163 GMT 16/12/2022 9:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 34 14.87 472 239 0.24 / 689.63 3 3
2 12 1172.76 3 15.08 1936 88 0.33 / 689.72 3 3
3 7 2008.92 30 14.71 2867 1265 1.59 / 690.98 3 3
4 13 1705.08 24 14.65 2533 891 2.48 / 691.87 3 3
5 13 1033.28 24 14.70 1739 614 3.10 / 692.49 3 4
6 13 326.88 24 14.84 838 298 3.39 / 692.78 3 4
7 13 28.48 24 14.93 399 143 3.54 / 692.93 3 3
8 8 0.00 165 14.89 352 865 4.40 / 693.79 3 8
Average= 4.23
(KJ/cycle)

Cycle 162 GMT 6/12/2022 11:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 34 14.86 487 246 0.25 / 685.28 3 3
2 12 1171.96 3 15.07 1935 87 0.33 / 685.37 3 3
3 7 2009.44 30 14.72 2862 1264 1.60 / 686.63 3 3
4 13 1691.32 24 14.66 2522 887 2.48 / 687.52 3 4
5 13 992.24 24 14.71 1680 593 3.08 / 688.11 3 4
6 13 306.16 24 14.85 793 283 3.36 / 688.40 3 4
7 13 30.40 24 14.93 397 142 3.50 / 688.54 3 3
8 8 0.04 165 14.90 346 851 4.35 / 689.39 3 8
Average= 4.23
(KJ/cycle)

Cycle 161 GMT 26/11/2022 14: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 34 14.87 480 243 0.24 / 680.90 3 3
2 12 1161.44 3 15.08 1914 87 0.33 / 680.99 3 3
3 7 2006.28 30 14.72 2857 1262 1.59 / 682.25 3 3
4 13 1702.68 24 14.66 2527 889 2.48 / 683.14 3 5
5 13 996.64 24 14.71 1679 593 3.07 / 683.73 3 4
6 13 309.08 24 14.85 805 287 3.36 / 684.02 3 4
7 13 55.48 24 14.92 439 157 3.52 / 684.18 3 3
8 8 0.08 165 14.89 349 857 4.37 / 685.04 3 7
Average= 4.23
(KJ/cycle)

Cycle 160 GMT 16/11/2022 16: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 34 14.88 491 248 0.25 / 676.56 3 3
2 12 1176.48 3 15.08 1923 87 0.34 / 676.65 3 3
3 7 2005.60 30 14.71 2858 1261 1.60 / 677.91 3 3
4 13 1701.28 24 14.66 2534 892 2.49 / 678.80 3 4
5 13 971.96 24 14.72 1649 583 3.07 / 679.38 3 4
6 13 296.16 24 14.86 794 283 3.35 / 679.67 3 4
7 13 23.76 24 14.94 388 139 3.49 / 679.81 3 3
8 8 0.12 165 14.90 348 856 4.35 / 680.66 3 11
Average= 4.23
(KJ/cycle)

Cycle 159 GMT 6/11/2022 18:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 34 14.87 477 241 0.24 / 672.32 3 3
2 12 1173.96 3 15.07 1930 87 0.33 / 672.41 3 3
3 7 2012.00 30 14.71 2875 1269 1.60 / 673.68 3 3
4 13 1694.56 24 14.66 2520 887 2.48 / 674.56 3 3
5 13 1007.72 24 14.71 1696 599 3.08 / 675.16 3 4
6 13 318.32 24 14.85 819 292 3.37 / 675.45 3 4
7 8 0.08 165 14.91 349 859 4.23 / 676.31 3 6
Average= 4.23
(KJ/cycle)

Cycle 158 GMT 27/10/2022 20:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.72 34 14.87 487 246 0.25 / 668.14 3 3
2 12 1182.04 3 15.07 1943 88 0.33 / 668.23 3 3
3 7 2010.20 30 14.71 2870 1267 1.60 / 669.49 3 4
4 13 1706.96 24 14.65 2536 892 2.49 / 670.38 3 3
5 13 858.92 24 14.74 1516 536 3.03 / 670.92 3 4
6 13 337.96 24 14.84 855 305 3.33 / 671.22 3 5
7 8 0.16 165 14.91 348 856 4.19 / 672.08 3 5
Average= 4.23
(KJ/cycle)

Cycle 157 GMT 17/10/2022 22:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 34 14.88 497 251 0.25 / 663.99 3 3
2 12 1181.64 3 15.08 1955 88 0.34 / 664.08 3 3
3 7 2012.08 30 14.71 2867 1265 1.61 / 665.34 3 3
4 13 1550.08 24 14.68 2351 828 2.43 / 666.17 3 3
5 13 882.88 24 14.73 1542 545 2.98 / 666.72 3 4
6 13 357.48 24 14.83 879 313 3.29 / 667.03 3 4
7 8 0.08 165 14.90 350 860 4.15 / 667.89 3 6
Average= 4.23
(KJ/cycle)

Cycle 156 GMT 8/10/2022 0:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 34 14.88 466 236 0.24 / 659.81 3 3
2 12 1155.76 3 15.08 1900 86 0.32 / 659.89 3 3
3 7 2003.40 30 14.70 2871 1266 1.59 / 661.16 3 3
4 13 1679.32 24 14.66 2501 880 2.47 / 662.04 3 5
5 13 977.00 24 14.72 1659 586 3.05 / 662.62 3 4
6 13 283.84 24 14.86 769 274 3.33 / 662.90 3 5
7 8 0.08 165 14.92 342 842 4.17 / 663.74 3 5
Average= 4.23
(KJ/cycle)

Cycle 155 GMT 28/ 9/2022 2:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 34 14.87 490 248 0.25 / 655.64 3 3
2 12 1166.84 3 15.08 1943 88 0.34 / 655.73 3 3
3 7 2011.24 30 14.71 2860 1262 1.60 / 656.99 3 3
4 13 1698.52 24 14.66 2519 886 2.48 / 657.87 3 4
5 13 979.84 24 14.72 1664 588 3.07 / 658.46 3 4
6 13 282.96 24 14.87 767 274 3.35 / 658.74 3 4
7 8 0.12 165 14.91 339 834 4.18 / 659.57 3 5
Average= 4.23
(KJ/cycle)

Cycle 154 GMT 18/ 9/2022 5: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 34 14.88 481 243 0.24 / 651.41 3 3
2 12 1189.28 3 15.08 1967 89 0.33 / 651.50 3 3
3 7 2006.64 30 14.72 2854 1260 1.59 / 652.76 3 3
4 13 1697.52 24 14.66 2519 886 2.48 / 653.65 3 4
5 13 996.80 24 14.72 1678 593 3.07 / 654.24 3 4
6 13 317.00 24 14.86 809 289 3.36 / 654.53 3 5
7 8 0.04 165 14.91 350 861 4.22 / 655.39 3 7
Average= 4.23
(KJ/cycle)

Cycle 153 GMT 8/ 9/2022 7:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 34 14.88 470 238 0.24 / 647.28 3 3
2 12 1173.56 3 15.08 1932 87 0.33 / 647.37 3 3
3 7 2008.36 30 14.70 2864 1263 1.59 / 648.63 3 3
4 13 1544.60 24 14.68 2346 827 2.41 / 649.46 3 4
5 13 1011.20 24 14.71 1695 598 3.01 / 650.05 3 4
6 13 289.76 24 14.87 771 275 3.29 / 650.33 3 4
7 8 0.24 165 14.92 341 839 4.13 / 651.17 3 9
Average= 4.23
(KJ/cycle)

Cycle 152 GMT 29/ 8/2022 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 34 14.88 489 247 0.25 / 643.09 3 3
2 12 1167.20 3 15.08 1920 87 0.33 / 643.17 3 3
3 7 2003.36 30 14.71 2854 1259 1.59 / 644.43 3 3
4 13 1695.52 24 14.66 2516 885 2.48 / 645.32 3 4
5 13 985.28 24 14.73 1665 589 3.07 / 645.91 3 4
6 13 296.68 24 14.87 783 279 3.35 / 646.19 3 4
7 8 0.20 165 14.92 347 854 4.20 / 647.04 3 6
Average= 4.23
(KJ/cycle)

Cycle 151 GMT 19/ 8/2022 11:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 34 14.88 482 244 0.24 / 638.90 3 3
2 12 1167.84 3 15.09 1912 87 0.33 / 638.99 3 3
3 7 2002.72 30 14.72 2846 1257 1.59 / 640.25 3 3
4 13 1690.36 24 14.66 2516 885 2.47 / 641.13 3 4
5 13 964.44 24 14.73 1637 579 3.05 / 641.71 3 4
6 13 280.44 24 14.87 762 272 3.32 / 641.98 3 4
7 8 0.08 165 14.91 348 856 4.18 / 642.84 3 6
Average= 4.23
(KJ/cycle)

Cycle 150 GMT 9/ 8/2022 14:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 34 14.89 472 239 0.24 / 634.73 3 3
2 12 1167.60 3 15.09 1915 87 0.33 / 634.81 3 3
3 7 2003.44 30 14.71 2857 1261 1.59 / 636.07 3 3
4 13 1668.60 24 14.67 2490 877 2.46 / 636.95 3 3
5 13 972.00 24 14.73 1652 584 3.05 / 637.53 3 4
6 13 282.04 24 14.87 763 272 3.32 / 637.81 3 4
7 8 0.08 165 14.92 347 854 4.17 / 638.66 3 7
Average= 4.23
(KJ/cycle)

Cycle 149 GMT 30/ 7/2022 16:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 34 14.88 494 250 0.25 / 630.54 3 3
2 12 1170.16 3 15.09 1927 87 0.34 / 630.62 3 3
3 7 2009.52 30 14.73 2846 1258 1.59 / 631.88 3 3
4 13 1690.12 24 14.67 2508 883 2.48 / 632.76 3 4
5 13 994.64 24 14.73 1672 591 3.07 / 633.36 3 4
6 13 302.48 24 14.87 797 284 3.35 / 633.64 3 4
7 8 0.08 165 14.92 344 847 4.20 / 634.49 3 6
Average= 4.23
(KJ/cycle)

Cycle 148 GMT 20/ 7/2022 18:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 34 14.89 468 237 0.24 / 626.35 3 3
2 12 1171.52 3 15.07 1927 87 0.32 / 626.44 3 3
3 7 2008.92 30 14.71 2865 1264 1.59 / 627.70 3 4
4 13 1677.48 24 14.67 2501 881 2.47 / 628.58 3 5
5 13 958.56 24 14.73 1630 576 3.05 / 629.16 3 4
6 13 272.96 24 14.88 753 269 3.31 / 629.43 3 4
7 8 0.12 165 14.92 349 859 4.17 / 630.29 3 6
Average= 4.23
(KJ/cycle)

Cycle 147 GMT 10/ 7/2022 20:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 34 14.89 486 246 0.25 / 622.15 3 3
2 12 1181.76 3 15.08 1946 88 0.33 / 622.24 3 3
3 7 2010.60 30 14.73 2866 1266 1.60 / 623.50 3 4
4 13 1690.96 24 14.67 2525 889 2.49 / 624.39 3 4
5 13 988.80 24 14.73 1675 592 3.08 / 624.98 3 4
6 13 298.16 24 14.87 785 280 3.36 / 625.26 3 4
7 8 0.04 165 14.92 345 849 4.21 / 626.11 3 5
Average= 4.23
(KJ/cycle)

Cycle 146 GMT 30/ 6/2022 22:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 34 14.89 478 242 0.24 / 617.95 3 3
2 12 1175.64 3 15.08 1927 87 0.33 / 618.04 3 3
3 7 2009.20 31 14.71 2863 1306 1.63 / 619.35 3 4
4 13 1698.04 24 14.66 2522 887 2.52 / 620.23 3 4
5 13 839.76 24 14.76 1489 527 3.05 / 620.76 3 5
6 13 318.64 24 14.86 815 291 3.34 / 621.05 3 5
7 8 0.08 165 14.92 345 849 4.19 / 621.90 3 7
Average= 4.23
(KJ/cycle)

Cycle 145 GMT 21/ 6/2022 1: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.84 34 14.88 482 244 0.24 / 613.80 3 3
2 12 1170.36 3 15.08 1930 87 0.33 / 613.89 3 3
3 7 2007.20 30 14.71 2859 1262 1.59 / 615.15 3 3
4 13 1541.48 24 14.69 2349 828 2.42 / 615.98 3 4
5 13 1015.52 24 14.72 1706 603 3.02 / 616.58 3 4
6 13 299.00 24 14.87 791 282 3.31 / 616.87 3 4
7 8 0.12 165 14.92 344 847 4.15 / 617.71 3 4
Average= 4.23
(KJ/cycle)

Cycle 144 GMT 11/ 6/2022 3: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 34 14.89 476 241 0.24 / 609.37 3 3
2 12 1169.36 3 15.08 1934 87 0.33 / 609.46 3 3
3 7 2009.48 30 14.71 2869 1266 1.59 / 610.72 3 3
4 13 1706.60 24 14.66 2541 894 2.49 / 611.62 3 4
5 13 859.00 24 14.75 1515 536 3.02 / 612.15 3 4
6 13 323.40 24 14.86 830 296 3.32 / 612.45 3 4
7 13 26.60 24 14.94 393 141 3.46 / 612.59 3 3
8 8 0.00 165 14.91 343 844 4.31 / 613.43 3 6
9 14 0.00 25 14.88 340 126 4.43 / 613.56 3 11
Average= 4.23
(KJ/cycle)

Cycle 143 GMT 1/ 6/2022 5: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 34 14.89 472 239 0.24 / 604.91 3 3
2 12 1167.92 3 15.09 1930 87 0.33 / 605.00 3 3
3 7 2010.76 31 14.72 2867 1308 1.63 / 606.30 3 3
4 13 1550.00 24 14.69 2356 831 2.47 / 607.13 3 3
5 13 1012.00 24 14.72 1704 602 3.07 / 607.74 3 4
6 13 294.64 24 14.87 785 280 3.35 / 608.02 3 5
7 13 31.32 24 14.95 393 141 3.49 / 608.16 3 3
8 8 0.16 165 14.91 343 844 4.33 / 609.00 3 7
9 14 0.16 25 14.89 339 126 4.46 / 609.13 3 9
Average= 4.23
(KJ/cycle)

Cycle 142 GMT 22/ 5/2022 7:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 34 14.89 481 244 0.24 / 600.79 3 3
2 12 1163.60 3 15.10 1922 87 0.33 / 600.88 3 3
3 7 2010.52 30 14.72 2864 1265 1.60 / 602.15 3 3
4 13 1539.56 24 14.69 2337 824 2.42 / 602.97 3 4
5 13 867.08 24 14.76 1524 540 2.96 / 603.51 3 4
6 13 340.92 24 14.86 846 302 3.26 / 603.81 3 5
7 8 0.16 165 14.92 348 857 4.12 / 604.67 3 6
Average= 4.23
(KJ/cycle)

Cycle 141 GMT 12/ 5/2022 9:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 34 14.89 464 235 0.23 / 596.47 3 3
2 12 1167.80 3 15.10 1925 87 0.32 / 596.56 3 3
3 7 2009.56 30 14.72 2856 1261 1.58 / 597.82 3 3
4 13 1701.68 24 14.67 2536 893 2.48 / 598.71 3 4
5 13 988.24 24 14.74 1661 588 3.06 / 599.30 3 4
6 13 280.64 24 14.88 769 275 3.34 / 599.57 3 4
7 13 26.08 24 14.95 392 141 3.48 / 599.71 3 4
8 8 0.00 165 14.92 341 839 4.32 / 600.55 3 7
Average= 4.23
(KJ/cycle)

Cycle 140 GMT 2/ 5/2022 11:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 34 14.88 479 242 0.24 / 592.36 3 3
2 12 1174.88 3 15.08 1940 88 0.33 / 592.45 3 3
3 7 2003.48 30 14.72 2854 1260 1.59 / 593.71 3 3
4 13 1540.32 24 14.70 2336 824 2.41 / 594.53 3 4
5 13 915.48 24 14.74 1583 560 2.97 / 595.09 3 4
6 13 366.80 24 14.85 887 316 3.29 / 595.41 3 4
7 8 0.08 165 14.92 336 827 4.12 / 596.23 3 6
Average= 4.23
(KJ/cycle)

Cycle 139 GMT 22/ 4/2022 13:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 34 14.89 482 244 0.24 / 587.96 3 3
2 12 1189.28 3 15.08 1939 88 0.33 / 588.05 3 3
3 7 2008.60 31 14.72 2869 1309 1.64 / 589.36 3 3
4 13 1698.84 24 14.67 2521 888 2.53 / 590.25 3 4
5 13 991.52 24 14.73 1680 594 3.12 / 590.84 3 4
6 13 298.52 24 14.88 790 282 3.40 / 591.12 3 5
7 13 26.60 24 14.95 384 138 3.54 / 591.26 3 3
8 8 0.04 165 14.92 347 854 4.40 / 592.12 3 5
Average= 4.23
(KJ/cycle)

Cycle 138 GMT 12/ 4/2022 15:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 34 14.89 471 238 0.24 / 583.67 3 3
2 12 1161.92 3 15.09 1915 87 0.33 / 583.75 3 3
3 7 2003.36 30 14.72 2854 1260 1.59 / 585.01 3 3
4 13 1539.28 24 14.69 2340 825 2.41 / 585.84 3 4
5 13 1007.76 24 14.73 1702 602 3.01 / 586.44 3 4
6 13 298.84 24 14.88 795 284 3.30 / 586.73 3 4
7 13 33.00 24 14.95 401 144 3.44 / 586.87 3 3
8 8 0.12 165 14.92 345 849 4.29 / 587.72 3 7
Average= 4.23
(KJ/cycle)

Cycle 137 GMT 2/ 4/2022 18: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 34 14.90 467 237 0.24 / 579.35 3 3
2 12 1181.72 3 15.09 1948 88 0.32 / 579.44 3 3
3 7 2007.56 30 14.72 2859 1263 1.59 / 580.70 3 4
4 13 1683.88 24 14.67 2516 886 2.47 / 581.59 3 4
5 13 967.48 24 14.74 1650 584 3.06 / 582.17 3 4
6 13 277.16 24 14.89 749 268 3.32 / 582.44 3 4
7 13 49.60 24 14.95 420 151 3.48 / 582.59 3 3
8 8 0.04 165 14.92 340 837 4.31 / 583.43 3 7
Average= 4.23
(KJ/cycle)

Cycle 136 GMT 23/ 3/2022 20:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 34 14.90 457 232 0.23 / 575.01 3 3
2 12 1182.84 3 15.08 1944 88 0.32 / 575.10 3 3
3 7 2007.88 31 14.72 2858 1304 1.62 / 576.40 3 3
4 13 1687.76 24 14.67 2509 883 2.51 / 577.28 3 4
5 13 975.52 24 14.74 1652 584 3.09 / 577.87 3 4
6 13 283.92 24 14.89 770 275 3.37 / 578.14 3 4
7 13 28.88 24 14.96 396 142 3.51 / 578.28 3 3
8 8 0.04 165 14.93 338 833 4.34 / 579.12 3 7
Average= 4.23
(KJ/cycle)

Cycle 135 GMT 13/ 3/2022 22:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.36 34 14.90 489 248 0.25 / 570.73 3 3
2 12 1162.60 3 15.09 1912 87 0.33 / 570.82 3 3
3 7 2009.88 30 14.72 2860 1263 1.60 / 572.08 3 3
4 13 1690.04 24 14.68 2519 887 2.48 / 572.97 3 4
5 13 970.00 24 14.74 1644 582 3.07 / 573.55 3 4
6 13 289.24 24 14.89 767 274 3.34 / 573.82 3 4
7 13 26.60 24 14.96 387 139 3.48 / 573.96 3 3
8 8 0.00 165 14.93 330 813 4.29 / 574.78 3 7
Average= 4.23
(KJ/cycle)

Cycle 134 GMT 4/ 3/2022 0:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.80 34 14.90 480 243 0.24 / 566.38 3 3
2 12 1171.80 3 15.09 1944 88 0.33 / 566.47 3 3
3 7 2004.80 30 14.74 2860 1265 1.60 / 567.73 3 3
4 13 1560.40 24 14.69 2372 836 2.43 / 568.57 3 4
5 13 1053.92 24 14.72 1759 621 3.05 / 569.19 3 4
6 13 348.12 24 14.86 851 304 3.36 / 569.49 3 4
7 13 36.16 24 14.96 401 144 3.50 / 569.64 3 3
8 8 0.08 165 14.92 343 844 4.35 / 570.48 3 6
Average= 4.23
(KJ/cycle)

Cycle 133 GMT 22/ 2/2022 2:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 34 14.89 469 237 0.24 / 562.06 3 3
2 12 1179.60 3 15.09 1944 88 0.33 / 562.15 3 3
3 7 2004.76 30 14.74 2853 1262 1.59 / 563.41 3 3
4 13 1691.44 24 14.68 2501 881 2.47 / 564.29 3 3
5 13 983.48 24 14.74 1660 587 3.06 / 564.88 3 4
6 13 300.60 24 14.89 789 282 3.34 / 565.16 3 4
7 13 31.48 24 14.97 388 139 3.48 / 565.30 3 3
8 8 0.16 165 14.93 341 840 4.32 / 566.14 3 8
Average= 4.22
(KJ/cycle)

Cycle 132 GMT 12/ 2/2022 4:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 34 14.90 460 233 0.23 / 557.72 3 3
2 12 1176.84 3 15.09 1928 87 0.32 / 557.81 3 3
3 7 2009.72 30 14.73 2860 1264 1.58 / 559.07 3 3
4 13 1685.80 24 14.68 2515 886 2.47 / 559.96 3 4
5 13 976.08 24 14.74 1657 586 3.06 / 560.55 3 4
6 13 297.12 24 14.89 779 278 3.33 / 560.82 3 4
7 13 23.92 24 14.96 384 138 3.47 / 560.96 3 3
8 8 0.12 165 14.92 349 859 4.33 / 561.82 3 5
Average= 4.22
(KJ/cycle)

Cycle 131 GMT 2/ 2/2022 6:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 34 14.90 482 244 0.24 / 553.40 3 3
2 12 1181.12 3 15.08 1942 88 0.33 / 553.48 3 3
3 7 2007.20 30 14.73 2858 1263 1.59 / 554.75 3 3
4 13 1699.88 24 14.68 2521 888 2.48 / 555.63 3 4
5 13 986.88 24 14.74 1664 589 3.07 / 556.22 3 4
6 13 296.00 24 14.89 791 283 3.35 / 556.51 3 4
7 13 28.24 24 14.97 393 141 3.50 / 556.65 3 3
8 8 0.04 165 14.93 342 842 4.34 / 557.49 3 9
Average= 4.22
(KJ/cycle)

Cycle 130 GMT 23/ 1/2022 9: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 34 14.91 457 232 0.23 / 549.03 3 3
2 12 1163.84 3 15.10 1911 87 0.32 / 549.12 3 3
3 7 2002.80 30 14.74 2850 1260 1.58 / 550.38 3 3
4 13 1686.92 24 14.68 2500 881 2.46 / 551.26 3 4
5 13 992.52 24 14.74 1676 593 3.05 / 551.85 3 4
6 13 312.08 24 14.88 816 291 3.34 / 552.15 3 4
7 13 27.24 24 14.96 397 143 3.49 / 552.29 3 3
8 8 0.08 165 14.93 350 862 4.35 / 553.15 3 9
Average= 4.22
(KJ/cycle)

Cycle 129 GMT 13/ 1/2022 11:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 34 14.90 500 253 0.25 / 544.94 3 3
2 12 1158.96 3 15.11 1922 87 0.34 / 545.03 3 3
3 7 2004.88 30 14.73 2848 1259 1.60 / 546.29 3 4
4 13 1691.44 24 14.68 2529 891 2.49 / 547.18 3 3
5 13 831.88 24 14.78 1474 523 3.01 / 547.70 3 4
6 13 305.32 24 14.89 794 284 3.30 / 547.99 3 4
7 8 0.08 165 14.95 331 816 4.11 / 548.80 3 6
Average= 4.22
(KJ/cycle)

Cycle 128 GMT 3/ 1/2022 13:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 34 14.90 482 244 0.24 / 540.78 3 3
2 12 1188.08 3 15.10 1946 88 0.33 / 540.87 3 3
3 7 2011.24 30 14.73 2868 1267 1.60 / 542.14 3 3
4 13 1550.72 24 14.70 2361 833 2.43 / 542.97 3 4
5 13 881.88 24 14.76 1542 546 2.98 / 543.52 3 4
6 13 352.72 24 14.87 861 307 3.29 / 543.82 3 5
7 8 0.12 165 14.94 351 865 4.15 / 544.69 3 6
Average= 4.22
(KJ/cycle)

Cycle 127 GMT 24/12/2021 15:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 34 14.90 463 235 0.23 / 536.40 3 3
2 12 1177.00 3 15.10 1929 87 0.32 / 536.48 3 3
3 7 2009.44 31 14.73 2865 1308 1.63 / 537.79 3 3
4 13 1685.36 24 14.69 2508 884 2.51 / 538.68 3 4
5 13 952.92 24 14.76 1626 576 3.09 / 539.25 3 4
6 13 277.60 24 14.90 766 274 3.36 / 539.53 3 4
7 13 22.72 24 14.97 392 141 3.51 / 539.67 3 3
8 8 0.08 165 14.93 354 872 4.38 / 540.54 3 6
Average= 4.22
(KJ/cycle)

Cycle 126 GMT 14/12/2021 17:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 34 14.92 481 244 0.24 / 532.25 3 3
2 12 1174.08 3 15.10 1934 88 0.33 / 532.34 3 3
3 7 2004.24 30 14.73 2863 1265 1.60 / 533.61 3 3
4 13 1538.20 24 14.70 2348 828 2.43 / 534.44 3 4
5 13 875.20 24 14.77 1537 545 2.97 / 534.98 3 4
6 13 337.80 24 14.87 857 306 3.28 / 535.29 3 5
7 8 0.28 165 14.93 355 875 4.15 / 536.16 3 7
Average= 4.22
(KJ/cycle)

Cycle 125 GMT 4/12/2021 19:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 34 14.90 493 250 0.25 / 528.05 3 3
2 12 1176.92 3 15.09 1925 87 0.34 / 528.13 3 3
3 7 2008.80 30 14.73 2869 1268 1.60 / 529.40 3 3
4 13 1700.76 24 14.68 2528 891 2.50 / 530.29 3 4
5 13 1130.00 24 14.72 1838 649 3.14 / 530.94 3 4
6 13 244.12 24 14.92 701 251 3.40 / 531.19 3 4
7 8 0.12 165 14.96 332 820 4.22 / 532.01 3 7
Average= 4.22
(KJ/cycle)

Cycle 124 GMT 24/11/2021 21:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 34 14.90 472 239 0.24 / 523.72 3 3
2 12 1174.92 3 15.10 1921 87 0.33 / 523.81 3 3
3 7 2010.16 30 14.74 2870 1269 1.60 / 525.08 3 3
4 13 1550.04 24 14.71 2349 829 2.42 / 525.91 3 3
5 13 1023.56 24 14.74 1720 608 3.03 / 526.52 3 4
6 13 311.80 24 14.89 805 288 3.32 / 526.80 3 4
7 13 30.88 24 14.97 393 141 3.46 / 526.94 3 3
8 8 -0.04 165 14.94 345 850 4.31 / 527.80 3 6
Average= 4.22
(KJ/cycle)

Cycle 123 GMT 14/11/2021 23:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 34 14.91 467 237 0.24 / 519.38 3 3
2 12 1164.32 3 15.11 1916 87 0.32 / 519.47 3 3
3 7 2007.32 31 14.73 2869 1310 1.63 / 520.78 3 3
4 13 1535.56 24 14.70 2332 823 2.46 / 521.60 3 4
5 13 1017.04 24 14.74 1709 605 3.06 / 522.20 3 4
6 13 305.52 24 14.89 806 288 3.35 / 522.49 3 4
7 13 29.88 24 14.97 402 144 3.49 / 522.64 3 3
8 8 0.04 165 14.93 344 847 4.34 / 523.48 3 8
Average= 4.22
(KJ/cycle)

Cycle 122 GMT 5/11/2021 1:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 34 14.91 495 251 0.25 / 515.13 3 3
2 12 1180.72 3 15.10 1946 88 0.34 / 515.22 3 3
3 7 2005.60 31 14.74 2861 1307 1.65 / 516.53 3 4
4 13 1699.96 24 14.68 2541 895 2.54 / 517.42 3 4
5 13 981.12 24 14.75 1663 589 3.13 / 518.01 3 4
6 13 294.04 24 14.90 782 280 3.41 / 518.29 3 4
7 8 0.16 165 14.95 345 851 4.26 / 519.14 3 8
Average= 4.22
(KJ/cycle)

Cycle 121 GMT 26/10/2021 3:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 34 14.92 474 240 0.24 / 510.79 3 3
2 12 1171.28 3 15.09 1920 87 0.33 / 510.88 3 3
3 7 2002.52 30 14.73 2867 1267 1.59 / 512.14 3 3
4 13 1671.72 24 14.69 2494 879 2.47 / 513.02 3 4
5 13 964.40 24 14.75 1652 585 3.06 / 513.61 3 4
6 13 277.12 24 14.91 763 273 3.33 / 513.88 3 4
7 13 25.00 24 14.98 395 142 3.47 / 514.02 3 3
8 8 0.04 165 14.94 348 858 4.33 / 514.88 3 7
Average= 4.22
(KJ/cycle)

Cycle 120 GMT 16/10/2021 6: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 34 14.90 476 241 0.24 / 506.58 3 3
2 12 1172.48 3 15.11 1945 88 0.33 / 506.67 3 3
3 7 2009.60 30 14.73 2860 1264 1.59 / 507.93 3 3
4 13 1688.44 24 14.69 2516 887 2.48 / 508.82 3 4
5 13 974.28 24 14.75 1664 589 3.07 / 509.41 3 4
6 13 291.76 24 14.90 789 282 3.35 / 509.69 3 4
7 8 0.16 165 14.95 348 858 4.21 / 510.55 3 5
Average= 4.22
(KJ/cycle)

Cycle 119 GMT 6/10/2021 8: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 34 14.92 491 249 0.25 / 502.47 3 3
2 12 1163.20 3 15.11 1926 87 0.34 / 502.55 3 3
3 7 2005.44 30 14.74 2852 1261 1.60 / 503.81 3 3
4 13 1526.80 24 14.71 2324 820 2.42 / 504.63 3 3
5 13 860.68 24 14.78 1522 540 2.96 / 505.17 3 4
6 13 322.96 24 14.89 831 297 3.25 / 505.47 3 4
7 8 0.08 165 14.95 352 868 4.12 / 506.34 3 7
Average= 4.22
(KJ/cycle)

Cycle 118 GMT 26/ 9/2021 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 34 14.91 472 239 0.24 / 498.25 3 3
2 12 1176.32 3 15.10 1927 87 0.33 / 498.34 3 3
3 7 2008.68 30 14.73 2859 1263 1.59 / 499.61 3 3
4 13 1682.92 24 14.70 2510 886 2.48 / 500.49 3 4
5 13 966.60 24 14.76 1652 585 3.06 / 501.08 3 4
6 13 285.48 24 14.91 774 277 3.34 / 501.35 3 4
7 8 0.12 165 14.96 350 864 4.20 / 502.22 3 5
Average= 4.22
(KJ/cycle)

Cycle 117 GMT 16/ 9/2021 12:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 34 14.92 472 239 0.24 / 494.13 3 3
2 12 1166.72 3 15.10 1943 88 0.33 / 494.22 3 3
3 7 2004.20 30 14.74 2858 1264 1.59 / 495.48 3 3
4 13 1536.48 24 14.71 2334 824 2.42 / 496.31 3 4
5 13 850.64 24 14.79 1503 534 2.95 / 496.84 3 5
6 13 322.68 24 14.89 831 297 3.25 / 497.14 3 4
7 8 0.08 165 14.94 356 878 4.12 / 498.02 3 6
Average= 4.22
(KJ/cycle)

Cycle 116 GMT 6/ 9/2021 14:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 34 14.91 502 254 0.25 / 489.86 3 3
2 12 1200.32 3 15.10 1964 89 0.34 / 489.95 3 3
3 7 2006.24 31 14.74 2863 1308 1.65 / 491.26 3 4
4 13 1691.80 24 14.69 2529 892 2.54 / 492.15 3 4
5 13 974.60 24 14.76 1665 590 3.13 / 492.74 3 4
6 13 294.24 24 14.91 790 283 3.42 / 493.03 3 4
7 8 0.04 165 14.95 351 866 4.28 / 493.89 3 6
Average= 4.22
(KJ/cycle)

Cycle 115 GMT 27/ 8/2021 16:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 34 14.91 478 242 0.24 / 485.69 3 3
2 12 1172.76 3 15.10 1926 87 0.33 / 485.78 3 3
3 7 2006.88 30 14.75 2865 1268 1.60 / 487.04 3 3
4 13 1538.32 24 14.72 2340 827 2.42 / 487.87 3 4
5 13 880.28 24 14.78 1541 547 2.97 / 488.42 3 4
6 13 349.08 24 14.88 867 310 3.28 / 488.73 3 4
7 8 0.16 165 14.95 358 883 4.16 / 489.61 3 6
Average= 4.22
(KJ/cycle)

Cycle 114 GMT 17/ 8/2021 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 34 14.91 473 240 0.24 / 481.48 3 3
2 12 1179.40 3 15.11 1942 88 0.33 / 481.57 3 3
3 7 2007.64 30 14.75 2856 1264 1.59 / 482.83 3 3
4 13 1683.60 24 14.70 2506 884 2.48 / 483.71 3 4
5 13 971.08 24 14.77 1652 586 3.06 / 484.30 3 4
6 13 288.24 24 14.91 785 281 3.34 / 484.58 3 4
7 8 0.12 165 14.96 351 866 4.21 / 485.45 3 9
Average= 4.22
(KJ/cycle)

Cycle 113 GMT 7/ 8/2021 21:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 34 14.92 491 249 0.25 / 477.27 3 3
2 12 1184.60 3 15.11 1947 88 0.34 / 477.36 3 3
3 7 2008.28 30 14.75 2863 1267 1.60 / 478.63 3 4
4 13 1533.60 25 14.72 2343 862 2.47 / 479.49 3 4
5 13 866.28 25 14.78 1522 562 3.03 / 480.05 3 4
6 13 316.68 25 14.90 824 307 3.34 / 480.36 3 4
7 8 0.12 165 14.95 356 878 4.21 / 481.24 3 11
Average= 4.22
(KJ/cycle)

Cycle 112 GMT 28/ 7/2021 23:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 34 14.91 489 248 0.25 / 473.00 3 3
2 12 1176.96 3 15.11 1958 89 0.34 / 473.09 3 3
3 7 2008.68 30 14.75 2873 1271 1.61 / 474.36 3 3
4 13 1699.76 25 14.69 2543 934 2.54 / 475.29 3 4
5 13 970.52 25 14.77 1652 610 3.15 / 475.90 3 4
6 13 252.92 25 14.93 731 273 3.42 / 476.18 3 4
7 8 0.00 165 14.96 344 849 4.27 / 477.02 3 6
Average= 4.22
(KJ/cycle)

Cycle 111 GMT 19/ 7/2021 1:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 34 14.92 488 248 0.25 / 468.74 3 3
2 12 1174.04 3 15.11 1940 88 0.34 / 468.83 3 3
3 7 2010.36 30 14.74 2858 1264 1.60 / 470.09 3 3
4 13 1692.12 25 14.70 2531 930 2.53 / 471.02 3 4
5 13 829.88 25 14.79 1489 551 3.08 / 471.57 3 5
6 13 290.20 25 14.90 793 295 3.38 / 471.87 3 4
7 8 0.12 165 14.95 359 886 4.26 / 472.75 3 7
Average= 4.22
(KJ/cycle)

Cycle 110 GMT 9/ 7/2021 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 34 14.92 478 242 0.24 / 464.56 3 3
2 12 1172.76 3 15.10 1941 88 0.33 / 464.64 3 3
3 7 2003.92 30 14.74 2855 1262 1.59 / 465.91 3 3
4 13 1547.40 25 14.71 2366 870 2.46 / 466.78 3 3
5 13 857.76 25 14.78 1526 564 3.03 / 467.34 3 4
6 13 301.64 25 14.90 793 295 3.32 / 467.64 3 4
7 8 0.08 165 14.95 346 853 4.18 / 468.49 3 5
Average= 4.22
(KJ/cycle)

Cycle 109 GMT 29/ 6/2021 6: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 34 14.92 487 247 0.25 / 460.31 3 3
2 12 1167.48 3 15.11 1933 88 0.33 / 460.39 3 3
3 7 2002.72 30 14.75 2855 1263 1.60 / 461.66 3 3
4 13 1687.08 25 14.70 2522 927 2.52 / 462.58 3 4
5 13 834.04 25 14.80 1490 551 3.08 / 463.14 3 4
6 13 312.24 25 14.90 819 305 3.38 / 463.44 3 4
7 8 0.00 165 14.95 354 873 4.25 / 464.31 3 5
Average= 4.22
(KJ/cycle)

Cycle 108 GMT 19/ 6/2021 8:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.16 34 14.91 501 254 0.25 / 456.06 3 3
2 12 1164.96 3 15.12 1919 87 0.34 / 456.14 3 3
3 7 2005.48 30 14.75 2845 1259 1.60 / 457.40 3 3
4 13 1556.04 25 14.72 2374 874 2.47 / 458.28 3 3
5 13 1023.92 25 14.76 1712 632 3.11 / 458.91 3 4
6 13 285.20 25 14.92 778 290 3.40 / 459.20 3 4
7 8 0.08 165 14.96 349 861 4.26 / 460.06 3 5
Average= 4.22
(KJ/cycle)

Cycle 107 GMT 9/ 6/2021 10:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 34 14.91 489 248 0.25 / 451.82 3 3
2 12 1167.36 3 15.11 1924 87 0.34 / 451.91 3 3
3 7 2008.24 30 14.74 2866 1267 1.60 / 453.18 3 3
4 13 1553.96 25 14.71 2359 868 2.47 / 454.04 3 4
5 13 879.88 25 14.78 1543 570 3.04 / 454.61 3 4
6 13 317.00 25 14.90 827 308 3.35 / 454.92 3 5
7 8 0.20 165 14.95 357 881 4.23 / 455.80 3 6
Average= 4.22
(KJ/cycle)

Cycle 106 GMT 30/ 5/2021 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 34 14.91 476 241 0.24 / 447.40 3 3
2 12 1163.00 3 15.11 1910 87 0.33 / 447.48 3 3
3 7 2004.88 31 14.75 2863 1309 1.64 / 448.79 3 4
4 13 1695.60 25 14.70 2524 928 2.56 / 449.72 3 4
5 13 943.52 25 14.77 1625 600 3.16 / 450.32 3 4
6 13 241.76 25 14.94 707 264 3.43 / 450.58 3 4
7 13 17.12 25 14.99 381 143 3.57 / 450.73 3 3
8 8 0.16 165 14.95 343 846 4.42 / 451.57 3 7
Average= 4.22
(KJ/cycle)

Cycle 105 GMT 20/ 5/2021 14:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 34 14.92 486 247 0.25 / 443.17 3 3
2 12 1187.00 3 15.11 1943 88 0.33 / 443.26 3 3
3 7 2006.28 30 14.76 2859 1266 1.60 / 444.52 3 3
4 13 1558.28 25 14.72 2365 870 2.47 / 445.39 3 4
5 13 887.56 25 14.79 1555 575 3.05 / 445.97 3 4
6 13 341.60 25 14.89 863 321 3.37 / 446.29 3 4
7 8 0.12 165 14.95 351 866 4.23 / 447.16 3 5
Average= 4.22
(KJ/cycle)

Cycle 104 GMT 10/ 5/2021 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 34 14.93 462 235 0.23 / 438.94 3 3
2 12 1174.24 3 15.12 1944 88 0.32 / 439.02 3 3
3 7 2002.48 30 14.75 2858 1265 1.59 / 440.29 3 3
4 13 1671.20 25 14.71 2490 916 2.50 / 441.20 3 3
5 13 939.36 25 14.77 1628 601 3.10 / 441.81 3 4
6 13 239.40 25 14.93 719 268 3.37 / 442.07 3 4
7 8 0.16 165 14.96 344 849 4.22 / 442.92 3 6
Average= 4.22
(KJ/cycle)

Cycle 103 GMT 30/ 4/2021 18:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 34 14.93 474 241 0.24 / 434.69 3 3
2 12 1170.60 3 15.11 1939 88 0.33 / 434.78 3 3
3 7 2004.04 30 14.76 2861 1267 1.60 / 436.04 3 3
4 13 1692.40 25 14.71 2526 929 2.52 / 436.97 3 4
5 13 960.24 25 14.78 1641 606 3.13 / 437.58 3 4
6 13 259.72 25 14.93 736 275 3.41 / 437.85 3 4
7 8 0.00 165 14.97 343 847 4.25 / 438.70 3 7
Average= 4.22
(KJ/cycle)

Cycle 102 GMT 20/ 4/2021 20:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 34 14.91 471 239 0.24 / 430.58 3 3
2 12 1165.56 3 15.12 1931 88 0.33 / 430.67 3 3
3 7 2009.88 30 14.75 2868 1269 1.60 / 431.94 3 3
4 13 1531.16 25 14.73 2339 861 2.46 / 432.80 3 3
5 13 838.24 25 14.80 1499 555 3.01 / 433.35 3 4
6 13 185.36 25 14.95 631 236 3.25 / 433.59 3 4
7 8 0.12 165 14.96 348 859 4.11 / 434.45 3 10
Average= 4.22
(KJ/cycle)

Cycle 101 GMT 10/ 4/2021 22:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 34 14.94 476 242 0.24 / 426.20 3 3
2 12 1182.04 3 15.12 1947 88 0.33 / 426.29 3 3
3 7 2009.68 30 14.75 2868 1269 1.60 / 427.55 3 3
4 13 1537.72 25 14.73 2339 861 2.46 / 428.42 3 4
5 13 1005.20 25 14.76 1701 628 3.09 / 429.04 3 4
6 13 261.28 25 14.93 747 279 3.37 / 429.32 3 4
7 13 20.88 25 14.98 400 150 3.52 / 429.47 3 3
8 8 -0.04 165 14.94 353 870 4.39 / 430.34 3 8
Average= 4.22
(KJ/cycle)

Cycle 100 GMT 1/ 4/2021 0:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 34 14.92 469 238 0.24 / 421.99 3 3
2 12 1160.88 3 15.11 1918 87 0.32 / 422.08 3 3
3 7 2003.72 30 14.75 2859 1265 1.59 / 423.35 3 4
4 13 1675.56 25 14.71 2506 922 2.51 / 424.27 3 4
5 13 942.04 25 14.78 1619 598 3.11 / 424.87 3 4
6 13 231.32 25 14.94 690 258 3.37 / 425.12 3 4
7 8 0.12 165 14.97 337 832 4.20 / 425.96 3 5
Average= 4.22
(KJ/cycle)

Cycle 99 GMT 22/ 3/2021 2:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 34 14.92 469 238 0.24 / 417.63 3 3
2 12 1176.40 3 15.12 1929 87 0.33 / 417.71 3 3
3 7 2002.44 30 14.76 2853 1263 1.59 / 418.98 3 3
4 13 1689.36 25 14.71 2520 927 2.52 / 419.90 3 4
5 13 966.96 25 14.78 1650 610 3.13 / 420.51 3 4
6 13 260.28 25 14.94 729 272 3.40 / 420.78 3 4
7 13 21.36 25 15.00 365 137 3.53 / 420.92 3 3
8 8 0.04 165 14.96 338 834 4.37 / 421.76 3 8
Average= 4.22
(KJ/cycle)

Cycle 98 GMT 12/ 3/2021 5:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.36 34 14.94 473 240 0.24 / 413.23 3 3
2 12 1157.44 3 15.13 1918 87 0.33 / 413.32 3 3
3 7 2005.64 30 14.76 2859 1266 1.59 / 414.58 3 3
4 13 1672.08 25 14.72 2512 924 2.52 / 415.51 3 4
5 13 954.56 25 14.78 1635 604 3.12 / 416.11 3 4
6 13 254.76 25 14.93 730 272 3.39 / 416.38 3 4
7 13 20.64 25 14.99 390 146 3.54 / 416.53 3 3
8 8 0.08 165 14.95 348 858 4.40 / 417.39 3 8
Average= 4.22
(KJ/cycle)

Cycle 97 GMT 2/ 3/2021 7: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 34 14.93 459 233 0.23 / 408.99 3 3
2 12 1177.56 3 15.11 1948 88 0.32 / 409.08 3 3
3 7 2004.00 31 14.75 2860 1308 1.63 / 410.39 3 3
4 13 1680.88 25 14.71 2514 925 2.55 / 411.31 3 4
5 13 947.04 25 14.78 1630 602 3.16 / 411.91 3 4
6 13 246.80 25 14.94 711 266 3.42 / 412.18 3 4
7 8 0.12 165 14.98 328 811 4.23 / 412.99 3 7
Average= 4.21
(KJ/cycle)

Cycle 96 GMT 20/ 2/2021 9:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 34 14.93 489 248 0.25 / 404.76 3 3
2 12 1163.72 3 15.12 1925 87 0.34 / 404.85 3 3
3 7 2003.84 30 14.76 2860 1266 1.60 / 406.11 3 3
4 13 1691.08 25 14.71 2532 931 2.53 / 407.04 3 4
5 13 948.80 25 14.78 1635 604 3.14 / 407.65 3 4
6 13 247.68 25 14.94 714 267 3.40 / 407.91 3 4
7 8 0.16 165 14.97 341 842 4.25 / 408.76 3 6
Average= 4.21
(KJ/cycle)

Cycle 95 GMT 10/ 2/2021 11:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 34 14.93 475 241 0.24 / 400.32 3 3
2 12 1175.80 3 15.12 1923 87 0.33 / 400.41 3 3
3 7 2004.96 30 14.77 2856 1265 1.59 / 401.67 3 3
4 13 1854.04 25 14.70 2710 996 2.59 / 402.67 3 3
5 13 930.84 25 14.80 1611 596 3.19 / 403.26 3 4
6 13 247.76 25 14.94 722 270 3.46 / 403.53 3 4
7 13 21.00 25 15.00 372 139 3.60 / 403.67 3 3
8 8 0.16 165 14.96 339 837 4.43 / 404.51 3 6
Average= 4.21
(KJ/cycle)

Cycle 94 GMT 31/ 1/2021 13:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 34 14.94 482 245 0.24 / 396.11 3 3
2 12 1177.88 3 15.12 1952 89 0.33 / 396.20 3 3
3 7 2007.40 30 14.76 2871 1271 1.60 / 397.47 3 3
4 13 1536.40 25 14.74 2361 870 2.47 / 398.34 3 3
5 13 858.84 25 14.80 1526 565 3.04 / 398.91 3 4
6 13 305.92 25 14.91 806 300 3.34 / 399.21 3 4
7 8 0.04 165 14.96 352 869 4.21 / 400.08 3 6
Average= 4.21
(KJ/cycle)

Cycle 93 GMT 21/ 1/2021 15:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.52 34 14.94 510 259 0.26 / 391.88 3 3
2 12 1165.84 3 15.13 1917 87 0.35 / 391.96 3 3
3 7 2003.80 30 14.76 2859 1266 1.61 / 393.23 3 4
4 13 1691.88 25 14.71 2530 930 2.54 / 394.16 3 3
5 13 961.92 25 14.78 1636 605 3.15 / 394.76 3 4
6 13 242.04 25 14.95 704 263 3.41 / 395.03 3 4
7 8 0.08 165 14.97 341 842 4.25 / 395.87 3 6
Average= 4.21
(KJ/cycle)

Cycle 92 GMT 11/ 1/2021 18: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 34 14.94 497 252 0.25 / 387.60 3 3
2 12 1186.52 3 15.11 1953 89 0.34 / 387.69 3 3
3 7 2004.40 30 14.76 2873 1272 1.61 / 388.97 3 3
4 13 1682.52 25 14.72 2519 927 2.54 / 389.89 3 4
5 13 945.84 25 14.79 1627 602 3.14 / 390.49 3 4
6 13 242.48 25 14.95 718 268 3.41 / 390.76 3 4
7 8 0.24 165 14.98 346 855 4.27 / 391.62 3 6
Average= 4.21
(KJ/cycle)

Cycle 91 GMT 1/ 1/2021 20:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 34 14.93 473 240 0.24 / 383.31 3 3
2 12 1162.00 3 15.12 1926 87 0.33 / 383.39 3 3
3 7 2002.08 30 14.77 2866 1270 1.60 / 384.66 3 3
4 13 1669.16 25 14.73 2498 920 2.52 / 385.58 3 3
5 13 957.76 25 14.79 1652 611 3.13 / 386.20 3 4
6 13 256.36 25 14.94 740 276 3.40 / 386.47 3 4
7 8 0.20 165 14.98 356 880 4.28 / 387.35 3 6
Average= 4.21
(KJ/cycle)

Cycle 90 GMT 22/12/2020 22:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.12 34 14.94 500 254 0.25 / 379.00 3 3
2 12 1180.36 3 15.13 1946 88 0.34 / 379.09 3 3
3 7 2005.64 31 14.76 2873 1315 1.66 / 380.40 3 3
4 13 1678.84 25 14.72 2520 927 2.58 / 381.33 3 3
5 13 945.20 25 14.79 1628 602 3.19 / 381.93 3 4
6 13 235.80 25 14.95 708 265 3.45 / 382.20 3 4
7 8 0.20 165 14.98 353 873 4.32 / 383.07 3 6
Average= 4.21
(KJ/cycle)

Cycle 89 GMT 13/12/2020 0:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 34 14.95 473 240 0.24 / 374.72 3 3
2 12 1179.64 3 15.12 1936 88 0.33 / 374.81 3 3
3 7 2005.52 30 14.77 2856 1265 1.59 / 376.08 3 3
4 13 1696.08 25 14.72 2532 932 2.53 / 377.01 3 4
5 13 950.64 25 14.80 1629 603 3.13 / 377.61 3 4
6 13 253.12 25 14.95 732 274 3.40 / 377.88 3 4
7 8 0.08 165 14.98 348 860 4.26 / 378.74 3 10
Average= 4.21
(KJ/cycle)

Cycle 88 GMT 3/12/2020 2:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 34 14.94 472 240 0.24 / 370.44 3 3
2 12 1169.28 3 15.14 1915 87 0.33 / 370.53 3 3
3 7 2009.44 30 14.77 2879 1276 1.60 / 371.81 3 3
4 13 1700.32 25 14.72 2543 936 2.54 / 372.74 3 3
5 13 968.32 25 14.79 1658 613 3.15 / 373.35 3 4
6 13 269.80 25 14.95 749 280 3.43 / 373.63 3 4
7 8 0.20 165 14.99 343 848 4.28 / 374.48 3 7
Average= 4.21
(KJ/cycle)

Cycle 87 GMT 23/11/2020 5: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 34 14.94 479 243 0.24 / 366.21 3 3
2 12 1167.92 3 15.13 1926 87 0.33 / 366.30 3 3
3 7 2008.56 30 14.77 2878 1275 1.61 / 367.57 3 3
4 13 1681.72 25 14.72 2516 926 2.53 / 368.50 3 3
5 13 824.80 25 14.83 1481 549 3.08 / 369.05 3 4
6 13 296.08 25 14.93 802 299 3.38 / 369.35 3 4
7 8 0.16 165 14.98 346 855 4.24 / 370.20 3 5
Average= 4.21
(KJ/cycle)

Cycle 86 GMT 13/11/2020 7: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 34 14.95 489 249 0.25 / 362.02 3 3
2 12 1170.48 3 15.14 1933 88 0.34 / 362.10 3 3
3 7 2007.20 30 14.77 2862 1268 1.60 / 363.37 3 3
4 13 1548.04 25 14.75 2352 867 2.47 / 364.24 3 3
5 13 849.60 25 14.82 1512 560 3.03 / 364.80 3 4
6 13 294.64 25 14.93 806 301 3.33 / 365.10 3 4
7 8 0.12 165 14.98 351 868 4.20 / 365.97 3 8
Average= 4.21
(KJ/cycle)

Cycle 85 GMT 3/11/2020 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 34 14.94 496 252 0.25 / 357.77 3 3
2 12 1173.32 3 15.13 1937 88 0.34 / 357.86 3 3
3 7 2010.56 30 14.77 2873 1273 1.61 / 359.13 3 3
4 13 1548.08 25 14.75 2358 870 2.48 / 360.00 3 3
5 13 1022.68 25 14.79 1716 634 3.12 / 360.63 3 4
6 13 266.88 25 14.95 747 279 3.40 / 360.91 3 4
7 8 0.16 165 14.99 345 853 4.25 / 361.77 3 7
Average= 4.21
(KJ/cycle)

Cycle 84 GMT 24/10/2020 11:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 34 14.96 489 249 0.25 / 353.52 3 3
2 12 1181.28 3 15.14 1952 89 0.34 / 353.61 3 3
3 7 2010.12 30 14.79 2881 1278 1.62 / 354.89 3 3
4 13 1557.36 25 14.75 2375 876 2.49 / 355.77 3 3
5 13 867.28 25 14.82 1535 569 3.06 / 356.33 3 4
6 13 321.28 25 14.93 838 313 3.37 / 356.65 3 4
7 8 0.08 165 14.98 352 870 4.24 / 357.52 3 5
Average= 4.21
(KJ/cycle)

Cycle 83 GMT 14/10/2020 13:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 34 14.95 481 244 0.24 / 349.21 3 3
2 12 1166.36 3 15.15 1946 88 0.33 / 349.29 3 3
3 7 2003.24 31 14.78 2866 1313 1.65 / 350.61 3 3
4 13 1679.28 25 14.74 2514 926 2.57 / 351.53 3 3
5 13 950.84 25 14.81 1638 606 3.18 / 352.14 3 4
6 13 242.44 25 14.97 710 266 3.44 / 352.41 3 4
7 8 0.12 165 15.00 351 869 4.31 / 353.27 3 6
Average= 4.21
(KJ/cycle)

Cycle 82 GMT 4/10/2020 15:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 34 14.95 479 243 0.24 / 345.02 3 3
2 12 1176.28 3 15.15 1921 87 0.33 / 345.11 3 3
3 7 2003.40 30 14.80 2868 1273 1.60 / 346.38 3 3
4 13 1519.92 25 14.76 2314 854 2.46 / 347.23 3 3
5 13 836.28 25 14.84 1498 556 3.01 / 347.79 3 4
6 13 276.80 25 14.96 777 291 3.30 / 348.08 3 4
7 8 0.00 165 14.99 356 881 4.18 / 348.96 3 5
Average= 4.20
(KJ/cycle)

Cycle 81 GMT 24/ 9/2020 17:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.48 33 14.96 512 253 0.25 / 340.82 3 3
2 12 1184.08 3 15.15 1934 88 0.34 / 340.91 3 3
3 7 2003.00 30 14.79 2858 1268 1.61 / 342.18 3 3
4 13 1533.12 25 14.76 2340 863 2.47 / 343.04 3 3
5 13 835.96 25 14.84 1494 554 3.03 / 343.60 3 4
6 13 278.56 25 14.95 782 292 3.32 / 343.89 3 4
7 8 0.24 165 14.99 358 885 4.20 / 344.78 3 8
Average= 4.20
(KJ/cycle)

Cycle 80 GMT 14/ 9/2020 19:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 33 14.96 497 245 0.25 / 336.58 3 3
2 12 1172.04 3 15.15 1946 88 0.33 / 336.67 3 3
3 7 2004.04 30 14.78 2853 1265 1.60 / 337.93 3 3
4 13 1526.20 25 14.77 2321 857 2.46 / 338.79 3 3
5 13 1001.08 25 14.81 1703 631 3.09 / 339.42 3 4
6 13 258.92 25 14.97 734 275 3.36 / 339.70 3 4
7 8 0.04 165 15.00 354 876 4.24 / 340.57 3 5
Average= 4.20
(KJ/cycle)

Cycle 79 GMT 4/ 9/2020 22: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 33 14.96 505 249 0.25 / 332.33 3 3
2 12 1178.08 3 15.15 1937 88 0.34 / 332.42 3 3
3 7 2008.00 30 14.79 2860 1269 1.61 / 333.69 3 3
4 13 1547.44 25 14.76 2361 871 2.48 / 334.56 3 4
5 13 867.88 25 14.84 1539 571 3.05 / 335.13 3 4
6 13 315.16 25 14.95 833 311 3.36 / 335.44 3 5
7 8 0.20 165 15.00 360 891 4.25 / 336.33 3 7
Average= 4.20
(KJ/cycle)

Cycle 78 GMT 26/ 8/2020 0: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 33 14.98 496 245 0.25 / 328.06 3 3
2 12 1170.08 3 15.15 1938 88 0.33 / 328.15 3 3
3 7 2001.48 30 14.80 2856 1268 1.60 / 329.42 3 3
4 13 1660.88 25 14.76 2501 923 2.52 / 330.34 3 3
5 13 817.24 25 14.85 1474 547 3.07 / 330.89 3 4
6 13 287.84 25 14.96 798 298 3.37 / 331.19 3 5
7 8 0.04 165 15.00 362 896 4.27 / 332.08 3 7
Average= 4.20
(KJ/cycle)

Cycle 77 GMT 16/ 8/2020 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.48 33 14.98 499 247 0.25 / 323.78 3 3
2 12 1169.28 3 15.15 1946 88 0.34 / 323.87 3 3
3 7 2002.84 30 14.80 2869 1274 1.61 / 325.14 3 3
4 13 1679.40 25 14.75 2518 929 2.54 / 326.07 3 4
5 13 952.48 25 14.82 1644 609 3.15 / 326.68 3 4
6 13 238.44 25 14.99 715 268 3.41 / 326.95 3 4
7 8 0.16 165 15.02 351 870 4.28 / 327.82 3 6
Average= 4.20
(KJ/cycle)

Cycle 76 GMT 6/ 8/2020 4: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 33 14.99 499 247 0.25 / 319.46 3 3
2 12 1186.04 3 15.15 1964 89 0.34 / 319.55 3 3
3 7 2004.76 31 14.79 2867 1314 1.65 / 320.86 3 3
4 13 1673.20 25 14.75 2510 926 2.58 / 321.79 3 4
5 13 939.52 25 14.83 1627 603 3.18 / 322.39 3 4
6 13 229.28 25 15.00 706 265 3.44 / 322.65 3 4
7 8 -0.04 165 15.02 355 880 4.32 / 323.53 3 6
Average= 4.20
(KJ/cycle)

Cycle 75 GMT 27/ 7/2020 6:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 33 14.99 476 235 0.24 / 315.32 3 3
2 12 1169.12 3 15.15 1937 88 0.32 / 315.41 3 3
3 7 2003.68 30 14.79 2866 1272 1.60 / 316.68 3 3
4 13 1534.92 25 14.77 2351 868 2.46 / 317.55 3 4
5 13 842.72 25 14.85 1510 561 3.02 / 318.11 3 4
6 13 174.24 25 15.02 620 233 3.26 / 318.34 3 4
7 8 0.16 165 15.03 349 866 4.12 / 319.21 3 7
Average= 4.20
(KJ/cycle)

Cycle 74 GMT 17/ 7/2020 8:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 33 14.98 489 242 0.24 / 311.18 3 3
2 12 1160.76 3 15.16 1921 87 0.33 / 311.27 3 3
3 7 2007.48 30 14.80 2878 1278 1.61 / 312.55 3 3
4 13 1534.44 25 14.78 2350 868 2.48 / 313.41 3 4
5 13 863.56 25 14.85 1532 569 3.04 / 313.98 3 4
6 13 182.04 25 15.02 638 240 3.28 / 314.22 3 4
7 8 0.04 165 15.03 349 866 4.15 / 315.09 3 5
Average= 4.20
(KJ/cycle)

Cycle 73 GMT 7/ 7/2020 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 33 14.99 489 242 0.24 / 306.89 3 3
2 12 1172.24 3 15.17 1927 88 0.33 / 306.97 3 3
3 7 2002.28 30 14.80 2848 1265 1.59 / 308.24 3 4
4 13 1676.48 25 14.76 2522 931 2.52 / 309.17 3 3
5 13 947.92 25 14.84 1637 607 3.13 / 309.78 3 4
6 13 224.80 25 15.01 704 264 3.40 / 310.04 3 4
7 8 0.08 165 15.03 362 898 4.29 / 310.94 3 5
Average= 4.20
(KJ/cycle)

Cycle 72 GMT 27/ 6/2020 12:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 33 14.99 484 239 0.24 / 302.66 3 3
2 12 1179.16 3 15.15 1943 88 0.33 / 302.75 3 3
3 7 2010.64 30 14.79 2874 1275 1.60 / 304.03 3 3
4 13 1538.44 25 14.78 2346 867 2.47 / 304.89 3 3
5 13 851.64 25 14.86 1512 562 3.03 / 305.46 3 4
6 13 294.56 25 14.98 804 301 3.33 / 305.76 3 5
7 8 0.00 165 15.03 358 888 4.22 / 306.64 3 7
Average= 4.20
(KJ/cycle)

Cycle 71 GMT 17/ 6/2020 14:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.80 33 15.02 493 244 0.24 / 298.28 3 3
2 12 1161.80 3 15.16 1924 88 0.33 / 298.36 3 3
3 7 2003.12 30 14.82 2846 1265 1.60 / 299.63 3 3
4 13 1528.44 25 14.79 2340 865 2.46 / 300.49 3 3
5 13 1000.12 25 14.83 1699 630 3.09 / 301.12 3 4
6 13 259.04 25 15.00 754 283 3.38 / 301.41 3 4
7 13 27.04 25 15.06 405 152 3.53 / 301.56 3 3
8 8 -0.04 165 15.03 349 866 4.39 / 302.42 3 6
Average= 4.20
(KJ/cycle)

Cycle 70 GMT 7/ 6/2020 16:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 33 15.01 482 239 0.24 / 294.14 3 3
2 12 1185.04 3 15.16 1946 89 0.33 / 294.23 3 3
3 7 2004.28 30 14.81 2870 1275 1.60 / 295.50 3 3
4 13 1534.56 25 14.78 2352 869 2.47 / 296.37 3 4
5 13 835.08 25 14.87 1489 554 3.02 / 296.93 3 4
6 13 175.24 25 15.04 621 233 3.26 / 297.16 3 4
7 8 0.12 165 15.05 351 872 4.13 / 298.03 3 5
Average= 4.20
(KJ/cycle)

Cycle 69 GMT 28/ 5/2020 18:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 33 15.02 483 239 0.24 / 289.91 3 3
2 12 1167.96 3 15.17 1922 87 0.33 / 290.00 3 3
3 7 2004.00 30 14.80 2873 1276 1.60 / 291.28 3 3
4 13 1531.48 25 14.78 2343 866 2.47 / 292.14 3 4
5 13 831.96 25 14.87 1497 557 3.02 / 292.70 3 4
6 13 284.52 25 15.00 789 296 3.32 / 293.00 3 5
7 8 0.20 165 15.04 365 906 4.23 / 293.90 3 5
Average= 4.20
(KJ/cycle)

Cycle 68 GMT 18/ 5/2020 20:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 33 15.00 476 236 0.24 / 285.61 3 3
2 12 1177.48 3 15.18 1950 89 0.32 / 285.70 3 3
3 7 2003.84 30 14.82 2866 1274 1.60 / 286.98 3 3
4 13 1694.24 25 14.76 2520 930 2.53 / 287.91 3 3
5 13 967.52 25 14.85 1655 614 3.14 / 288.52 3 4
6 13 243.76 25 15.02 728 273 3.42 / 288.79 3 4
7 8 0.08 165 15.05 355 882 4.30 / 289.67 3 6
Average= 4.20
(KJ/cycle)

Cycle 67 GMT 8/ 5/2020 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 33 15.03 468 232 0.23 / 281.40 3 3
2 12 1174.04 3 15.17 1948 89 0.32 / 281.48 3 3
3 7 2003.32 30 14.81 2856 1269 1.59 / 282.75 3 3
4 13 1522.40 25 14.79 2335 863 2.45 / 283.62 3 4
5 13 852.08 25 14.88 1516 564 3.02 / 284.18 3 4
6 13 302.96 25 15.00 807 303 3.32 / 284.48 3 4
7 8 0.16 165 15.04 360 893 4.21 / 285.38 3 6
Average= 4.20
(KJ/cycle)

Cycle 66 GMT 29/ 4/2020 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 33 15.02 486 241 0.24 / 277.15 3 3
2 12 1168.36 3 15.17 1937 88 0.33 / 277.24 3 3
3 7 2001.88 30 14.81 2864 1272 1.60 / 278.51 3 3
4 13 1671.48 25 14.77 2522 931 2.53 / 279.44 3 4
5 13 922.48 25 14.87 1608 598 3.13 / 280.04 3 4
6 13 205.36 25 15.04 670 252 3.38 / 280.29 3 4
7 8 0.12 165 15.06 351 872 4.25 / 281.16 3 6
Average= 4.20
(KJ/cycle)

Cycle 65 GMT 19/ 4/2020 3:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 33 15.03 465 231 0.23 / 272.73 3 3
2 12 1174.64 3 15.17 1941 88 0.32 / 272.82 3 3
3 7 2002.12 30 14.82 2870 1276 1.59 / 274.09 3 3
4 13 1673.00 25 14.77 2512 928 2.52 / 275.02 3 4
5 13 914.48 25 14.88 1602 596 3.12 / 275.62 3 4
6 13 216.56 25 15.04 691 260 3.38 / 275.88 3 4
7 13 39.44 25 15.08 428 161 3.54 / 276.04 3 3
8 8 0.12 165 15.05 351 872 4.41 / 276.91 3 8
Average= 4.20
(KJ/cycle)

Cycle 64 GMT 9/ 4/2020 5:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 33 15.03 488 242 0.24 / 268.47 3 3
2 12 1174.76 3 15.17 1938 88 0.33 / 268.56 3 3
3 7 2008.88 31 14.81 2874 1319 1.65 / 269.87 3 3
4 13 1543.32 25 14.79 2355 871 2.52 / 270.75 3 3
5 13 846.68 25 14.88 1518 565 3.09 / 271.31 3 4
6 13 294.64 25 15.01 807 303 3.39 / 271.61 3 4
7 8 0.12 165 15.06 356 885 4.27 / 272.50 3 5
Average= 4.19
(KJ/cycle)

Cycle 63 GMT 30/ 3/2020 7:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 33 15.03 501 248 0.25 / 264.04 3 3
2 12 1171.28 3 15.18 1939 88 0.34 / 264.13 3 3
3 7 2003.24 30 14.82 2865 1274 1.61 / 265.40 3 3
4 13 1540.60 25 14.79 2357 872 2.48 / 266.27 3 4
5 13 990.28 25 14.85 1692 628 3.11 / 266.90 3 4
6 13 258.08 25 15.03 748 281 3.39 / 267.18 3 4
7 13 41.28 25 15.09 430 162 3.55 / 267.34 3 4
8 8 0.16 165 15.05 355 882 4.44 / 268.22 3 3
Average= 4.19
(KJ/cycle)

Cycle 62 GMT 20/ 3/2020 9:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 33 15.05 472 234 0.23 / 259.59 3 3
2 12 1168.08 3 15.18 1918 87 0.32 / 259.68 3 3
3 7 2003.96 30 14.82 2862 1272 1.59 / 260.95 3 3
4 13 1690.84 25 14.78 2537 937 2.53 / 261.89 3 4
5 13 831.32 25 14.90 1497 558 3.09 / 262.44 3 4
6 13 301.04 25 15.02 815 306 3.40 / 262.75 3 4
7 13 23.72 25 15.09 407 154 3.55 / 262.90 3 4
8 8 0.08 165 15.06 357 887 4.44 / 263.79 3 7
Average= 4.19
(KJ/cycle)

Cycle 61 GMT 10/ 3/2020 11:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 33 15.04 476 236 0.24 / 255.40 3 3
2 12 1160.88 3 15.19 1927 88 0.32 / 255.49 3 3
3 7 2003.72 31 14.82 2873 1320 1.64 / 256.81 3 3
4 13 1552.40 25 14.79 2364 874 2.52 / 257.68 3 3
5 13 864.48 25 14.89 1531 570 3.09 / 258.25 3 4
6 13 185.24 25 15.07 631 238 3.33 / 258.49 3 4
7 8 0.20 165 15.08 347 863 4.19 / 259.35 3 5
Average= 4.18
(KJ/cycle)

Cycle 60 GMT 29/ 2/2020 13:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 33 15.05 484 240 0.24 / 251.02 3 3
2 12 1176.84 3 15.18 1945 89 0.33 / 251.11 3 3
3 7 2003.16 30 14.83 2877 1280 1.61 / 252.39 3 3
4 13 1696.64 25 14.78 2553 943 2.55 / 253.33 3 4
5 13 964.16 25 14.87 1661 617 3.17 / 253.95 3 4
6 13 380.52 25 15.00 916 343 3.51 / 254.29 3 5
7 8 0.12 165 15.08 350 871 4.38 / 255.16 3 6
Average= 4.18
(KJ/cycle)

Cycle 59 GMT 19/ 2/2020 15:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 33 15.05 484 240 0.24 / 246.71 3 3
2 12 1178.80 3 15.19 1962 89 0.33 / 246.80 3 3
3 7 2009.92 30 14.82 2889 1284 1.61 / 248.08 3 3
4 13 1694.76 25 14.78 2535 937 2.55 / 249.02 3 3
5 13 949.12 25 14.88 1637 609 3.16 / 249.63 3 4
6 13 245.76 25 15.06 723 272 3.43 / 249.90 3 4
7 8 0.16 165 15.09 353 879 4.31 / 250.78 3 6
Average= 4.18
(KJ/cycle)

Cycle 58 GMT 9/ 2/2020 17:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 33 15.06 489 243 0.24 / 242.44 3 3
2 12 1175.44 3 15.18 1934 88 0.33 / 242.53 3 3
3 7 2001.92 31 14.82 2868 1318 1.65 / 243.85 3 3
4 13 1534.76 25 14.80 2348 869 2.52 / 244.72 3 3
5 13 839.80 25 14.91 1497 558 3.08 / 245.28 3 4
6 13 286.20 25 15.04 784 295 3.37 / 245.57 3 4
7 8 0.12 165 15.08 361 898 4.27 / 246.47 3 8
Average= 4.18
(KJ/cycle)

Cycle 57 GMT 30/ 1/2020 19:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.64 33 15.06 508 252 0.25 / 238.18 3 3
2 12 1186.84 3 15.19 1948 89 0.34 / 238.27 3 3
3 7 2001.88 30 14.85 2851 1270 1.61 / 239.54 3 3
4 13 1683.24 25 14.79 2524 933 2.54 / 240.47 3 4
5 13 798.72 25 14.93 1455 543 3.09 / 241.02 3 4
6 13 273.56 25 15.06 771 290 3.38 / 241.31 3 4
7 8 0.08 165 15.10 359 894 4.27 / 242.20 3 5
Average= 4.18
(KJ/cycle)

Cycle 56 GMT 20/ 1/2020 21:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 33 15.06 500 248 0.25 / 233.83 3 3
2 12 1178.92 3 15.20 1961 89 0.34 / 233.91 3 3
3 7 2003.40 31 14.83 2871 1320 1.66 / 235.23 3 3
4 13 1683.40 25 14.79 2525 934 2.59 / 236.17 3 3
5 13 942.44 25 14.90 1635 609 3.20 / 236.78 3 4
6 13 212.08 25 15.09 681 257 3.46 / 237.03 3 4
7 8 0.12 165 15.10 359 894 4.35 / 237.93 3 5
Average= 4.17
(KJ/cycle)

Cycle 55 GMT 10/ 1/2020 23:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 33 15.07 461 229 0.23 / 229.35 3 3
2 12 1168.16 3 15.20 1937 88 0.32 / 229.44 3 3
3 7 2004.80 30 14.84 2874 1280 1.60 / 230.72 3 3
4 13 1683.60 25 14.79 2524 933 2.53 / 231.65 3 3
5 13 947.80 25 14.90 1644 612 3.14 / 232.26 3 4
6 13 250.60 25 15.08 729 275 3.42 / 232.54 3 4
7 13 19.72 25 15.13 396 150 3.57 / 232.69 3 3
8 8 0.00 165 15.09 357 889 4.46 / 233.58 3 8
Average= 4.17
(KJ/cycle)

Cycle 54 GMT 1/ 1/2020 1:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 33 15.08 477 237 0.24 / 224.96 3 3
2 12 1169.36 3 15.20 1944 89 0.33 / 225.05 3 3
3 7 2002.48 30 14.83 2881 1282 1.61 / 226.33 3 3
4 13 1669.56 25 14.80 2512 929 2.54 / 227.26 3 3
5 13 941.84 25 14.90 1635 609 3.15 / 227.87 3 4
6 13 214.32 25 15.09 687 259 3.41 / 228.13 3 4
7 13 16.32 25 15.14 388 147 3.55 / 228.28 3 3
8 8 0.04 165 15.10 339 845 4.40 / 229.12 3 9
Average= 4.17
(KJ/cycle)

Cycle 53 GMT 22/12/2019 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 33 15.08 469 233 0.23 / 220.70 3 3
2 12 1171.12 3 15.21 1955 89 0.32 / 220.79 3 3
3 7 2003.64 30 14.83 2878 1280 1.60 / 222.07 3 3
4 13 1680.08 25 14.80 2517 931 2.53 / 223.00 3 3
5 13 804.40 25 14.94 1451 542 3.08 / 223.54 3 4
6 13 267.04 25 15.07 768 289 3.37 / 223.83 3 4
7 8 0.12 165 15.11 358 893 4.26 / 224.72 3 6
Average= 4.16
(KJ/cycle)

Cycle 52 GMT 12/12/2019 5:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 33 15.08 493 245 0.25 / 216.56 3 3
2 12 1174.08 3 15.21 1949 89 0.33 / 216.65 3 3
3 7 2005.68 30 14.84 2872 1279 1.61 / 217.93 3 3
4 13 1530.76 25 14.82 2353 872 2.48 / 218.80 3 3
5 13 852.48 25 14.93 1522 568 3.05 / 219.37 3 4
6 13 171.20 25 15.11 621 235 3.29 / 219.60 3 4
7 8 0.12 165 15.12 347 866 4.15 / 220.47 3 6
Average= 4.16
(KJ/cycle)

Cycle 51 GMT 2/12/2019 7:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.88 33 15.09 503 250 0.25 / 212.30 3 3
2 12 1165.56 3 15.20 1942 89 0.34 / 212.39 3 3
3 7 2006.96 31 14.84 2880 1325 1.66 / 213.71 3 3
4 13 1515.92 25 14.83 2325 862 2.53 / 214.57 3 3
5 13 827.16 25 14.94 1488 556 3.08 / 215.13 3 4
6 13 266.96 25 15.08 769 290 3.37 / 215.42 3 4
7 8 0.08 165 15.11 358 893 4.26 / 216.31 3 7
Average= 4.16
(KJ/cycle)

Cycle 50 GMT 22/11/2019 9:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 33 15.08 484 241 0.24 / 208.12 3 3
2 12 1171.16 3 15.20 1950 89 0.33 / 208.21 3 3
3 7 2004.24 30 14.84 2881 1283 1.61 / 209.49 3 3
4 13 1537.12 25 14.82 2349 870 2.48 / 210.36 3 3
5 13 856.72 25 14.93 1527 570 3.05 / 210.93 3 4
6 13 174.40 25 15.11 626 236 3.29 / 211.17 3 4
7 8 0.08 165 15.12 352 878 4.17 / 212.05 3 5
Average= 4.16
(KJ/cycle)

Cycle 49 GMT 12/11/2019 11:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 33 15.08 512 255 0.25 / 203.67 3 3
2 12 1179.16 3 15.21 1952 89 0.34 / 203.76 3 3
3 7 2004.84 30 14.85 2880 1283 1.63 / 205.04 3 3
4 13 1542.84 25 14.83 2368 878 2.50 / 205.92 3 4
5 13 1009.76 25 14.90 1721 641 3.15 / 206.56 3 4
6 13 262.68 25 15.09 758 286 3.43 / 206.84 3 4
7 13 25.20 25 15.15 406 154 3.59 / 207.00 3 3
8 8 0.04 165 15.11 354 883 4.47 / 207.88 3 7
Average= 4.16
(KJ/cycle)

Cycle 48 GMT 2/11/2019 13:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 33 15.09 490 244 0.24 / 199.42 3 3
2 12 1179.12 3 15.20 1944 89 0.33 / 199.51 3 3
3 7 2003.68 30 14.85 2882 1284 1.62 / 200.79 3 3
4 13 1516.60 25 14.84 2343 869 2.49 / 201.66 3 4
5 13 819.96 25 14.95 1488 556 3.04 / 202.22 3 4
6 13 270.56 25 15.08 779 294 3.34 / 202.51 3 4
7 8 0.08 165 15.12 361 901 4.24 / 203.41 3 6
Average= 4.15
(KJ/cycle)

Cycle 47 GMT 23/10/2019 15:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 33 15.09 501 249 0.25 / 195.12 3 3
2 12 1181.20 3 15.22 1956 89 0.34 / 195.21 3 3
3 7 2000.68 30 14.86 2868 1279 1.62 / 196.48 3 3
4 13 1666.40 25 14.82 2490 923 2.54 / 197.41 3 4
5 13 932.88 25 14.93 1628 608 3.15 / 198.01 3 4
6 13 217.64 25 15.11 697 263 3.41 / 198.28 3 4
7 8 0.00 165 15.13 360 899 4.31 / 199.18 3 6
Average= 4.15
(KJ/cycle)

Cycle 46 GMT 13/10/2019 17:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 33 15.10 490 244 0.24 / 190.84 3 3
2 12 1171.36 3 15.22 1924 88 0.33 / 190.93 3 3
3 7 2002.28 30 14.86 2872 1280 1.61 / 192.21 3 3
4 13 1677.52 25 14.82 2520 934 2.55 / 193.14 3 3
5 13 792.20 25 14.97 1454 544 3.09 / 193.69 3 4
6 13 256.04 25 15.10 749 283 3.37 / 193.97 3 4
7 8 0.12 165 15.13 359 896 4.27 / 194.87 3 6
Average= 4.15
(KJ/cycle)

Cycle 45 GMT 3/10/2019 19:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 33 15.11 508 253 0.25 / 186.55 3 3
2 12 1174.72 3 15.22 1968 90 0.34 / 186.64 3 3
3 7 2002.64 30 14.85 2873 1280 1.62 / 187.92 3 3
4 13 1665.72 25 14.82 2504 928 2.55 / 188.85 3 3
5 13 921.44 25 14.94 1606 600 3.15 / 189.45 3 4
6 13 203.88 25 15.12 669 253 3.40 / 189.70 3 4
7 8 0.00 165 15.14 359 897 4.30 / 190.60 3 5
Average= 4.14
(KJ/cycle)

Cycle 44 GMT 23/ 9/2019 21:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 33 15.10 492 245 0.25 / 182.38 3 3
2 12 1169.04 3 15.23 1950 89 0.33 / 182.47 3 3
3 7 2003.20 30 14.85 2876 1281 1.62 / 183.75 3 3
4 13 1531.08 25 14.85 2359 876 2.49 / 184.63 3 3
5 13 838.04 25 14.96 1501 561 3.05 / 185.19 3 4
6 13 159.84 25 15.14 605 229 3.28 / 185.42 3 4
7 8 0.04 165 15.14 352 879 4.16 / 186.30 3 6
Average= 4.14
(KJ/cycle)

Cycle 43 GMT 13/ 9/2019 23:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.12 32 15.10 513 248 0.25 / 178.10 3 3
2 12 1176.08 3 15.22 1969 90 0.34 / 178.19 3 3
3 7 2002.52 30 14.87 2879 1284 1.62 / 179.47 3 3
4 13 1659.28 25 14.83 2501 927 2.55 / 180.40 3 3
5 13 791.80 25 14.98 1452 544 3.09 / 180.94 3 4
6 13 267.56 25 15.10 776 293 3.39 / 181.23 3 4
7 8 0.12 165 15.14 361 902 4.29 / 182.14 3 6
Average= 4.14
(KJ/cycle)

Cycle 42 GMT 4/ 9/2019 1:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 32 15.11 491 237 0.24 / 173.75 3 3
2 12 1170.48 3 15.23 1928 88 0.33 / 173.84 3 3
3 7 2002.80 30 14.86 2876 1282 1.61 / 175.12 3 3
4 13 1673.12 25 14.83 2519 934 2.54 / 176.06 3 4
5 13 957.12 25 14.94 1657 619 3.16 / 176.68 3 4
6 13 225.08 25 15.12 710 268 3.43 / 176.94 3 4
7 8 0.08 165 15.14 362 904 4.33 / 177.85 3 6
Average= 4.14
(KJ/cycle)

Cycle 41 GMT 25/ 8/2019 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 32 15.11 501 242 0.24 / 169.42 3 3
2 12 1178.40 3 15.23 1953 89 0.33 / 169.51 3 3
3 7 2003.52 30 14.87 2880 1285 1.62 / 170.79 3 3
4 13 1680.68 25 14.83 2530 938 2.55 / 171.73 3 4
5 13 950.96 25 14.95 1645 615 3.17 / 172.34 3 5
6 13 224.40 25 15.13 703 266 3.43 / 172.61 3 4
7 8 0.04 165 15.15 362 905 4.34 / 173.52 3 7
Average= 4.13
(KJ/cycle)

Cycle 40 GMT 15/ 8/2019 5:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 32 15.11 492 238 0.24 / 165.12 3 3
2 12 1169.64 3 15.23 1940 89 0.33 / 165.21 3 3
3 7 2005.88 30 14.86 2888 1287 1.61 / 166.50 3 3
4 13 1528.08 25 14.86 2345 871 2.49 / 167.37 3 4
5 13 973.40 25 14.93 1685 629 3.11 / 168.00 3 4
6 13 233.88 25 15.12 721 273 3.39 / 168.27 3 4
7 8 0.20 165 15.15 363 907 4.29 / 169.18 3 5
Average= 4.13
(KJ/cycle)

Cycle 39 GMT 5/ 8/2019 7:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 32 15.11 520 251 0.25 / 160.78 3 3
2 12 1182.04 3 15.22 1955 89 0.34 / 160.87 3 3
3 7 2002.08 31 14.86 2877 1325 1.67 / 162.19 3 3
4 13 1669.64 25 14.83 2522 935 2.60 / 163.13 3 3
5 13 920.16 25 14.96 1619 606 3.21 / 163.73 3 4
6 13 187.04 25 15.15 651 247 3.45 / 163.98 3 4
7 8 0.08 165 15.16 361 903 4.36 / 164.88 3 5
Average= 4.12
(KJ/cycle)

Cycle 38 GMT 26/ 7/2019 9:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 32 15.11 490 237 0.24 / 156.44 3 3
2 12 1170.08 3 15.24 1957 89 0.33 / 156.53 3 3
3 7 2005.32 30 14.88 2882 1287 1.61 / 157.81 3 3
4 13 1698.20 25 14.84 2530 939 2.55 / 158.75 3 3
5 13 829.68 25 14.99 1498 561 3.11 / 159.31 3 4
6 13 280.68 25 15.11 791 299 3.41 / 159.61 3 4
7 8 0.28 165 15.15 366 915 4.33 / 160.53 3 6
Average= 4.12
(KJ/cycle)

Cycle 37 GMT 16/ 7/2019 11:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 32 15.13 497 241 0.24 / 152.14 3 3
2 12 1165.40 3 15.24 1931 88 0.33 / 152.23 3 3
3 7 2006.88 31 14.88 2875 1326 1.66 / 153.55 3 3
4 13 1528.20 25 14.87 2348 873 2.53 / 154.43 3 4
5 13 836.84 25 14.98 1503 563 3.09 / 154.99 3 4
6 13 287.00 25 15.11 799 302 3.39 / 155.29 3 4
7 8 0.04 165 15.15 363 907 4.30 / 156.20 3 6
Average= 4.11
(KJ/cycle)

Cycle 36 GMT 6/ 7/2019 13:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 32 15.13 499 242 0.24 / 147.98 3 3
2 12 1175.64 3 15.24 1942 89 0.33 / 148.07 3 3
3 7 2003.44 30 14.87 2875 1283 1.61 / 149.35 3 3
4 13 1520.76 25 14.87 2339 870 2.48 / 150.22 3 3
5 13 819.24 25 14.99 1485 557 3.04 / 150.78 3 4
6 13 154.28 25 15.16 595 226 3.26 / 151.00 3 4
7 8 0.08 165 15.17 358 896 4.16 / 151.90 3 9
Average= 4.11
(KJ/cycle)

Cycle 35 GMT 26/ 6/2019 15:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 32 15.13 489 237 0.24 / 143.66 3 3
2 12 1168.28 3 15.25 1930 88 0.33 / 143.75 3 3
3 7 2004.52 30 14.88 2892 1291 1.62 / 145.04 3 4
4 13 1695.76 25 14.84 2556 948 2.56 / 145.98 3 4
5 13 814.72 25 15.00 1483 556 3.12 / 146.54 3 4
6 13 265.92 25 15.13 772 292 3.41 / 146.83 3 4
7 8 0.04 165 15.16 362 906 4.32 / 147.74 3 5
Average= 4.10
(KJ/cycle)

Cycle 34 GMT 16/ 6/2019 17:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 32 15.13 490 237 0.24 / 139.49 3 3
2 12 1163.92 3 15.24 1942 89 0.33 / 139.58 3 3
3 7 2006.76 30 14.87 2885 1287 1.61 / 140.87 3 3
4 13 1533.00 25 14.87 2352 874 2.49 / 141.74 3 3
5 13 835.40 25 14.99 1517 568 3.06 / 142.31 3 4
6 13 157.84 25 15.17 603 229 3.28 / 142.54 3 4
7 8 0.08 165 15.17 353 884 4.17 / 143.42 3 6
Average= 4.10
(KJ/cycle)

Cycle 33 GMT 6/ 6/2019 19: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 32 15.12 524 254 0.25 / 135.17 3 3
2 12 1167.44 3 15.25 1954 89 0.34 / 135.25 3 3
3 7 2003.08 31 14.87 2872 1324 1.67 / 136.58 3 3
4 13 1533.56 25 14.88 2352 875 2.54 / 137.45 3 3
5 13 973.36 25 14.96 1681 629 3.17 / 138.08 3 4
6 13 212.92 25 15.15 690 261 3.43 / 138.34 3 4
7 8 0.12 165 15.17 363 909 4.34 / 139.25 3 6
Average= 4.10
(KJ/cycle)

Cycle 32 GMT 27/ 5/2019 21: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 32 15.13 480 232 0.23 / 130.59 3 3
2 12 1173.84 3 15.25 1956 89 0.32 / 130.68 3 3
3 7 2002.68 31 14.88 2883 1330 1.65 / 132.01 3 3
4 13 1537.40 25 14.87 2368 880 2.53 / 132.89 3 4
5 13 844.76 25 14.99 1520 570 3.10 / 133.46 3 4
6 13 731.60 25 14.99 1377 516 3.62 / 133.98 3 4
7 8 0.16 165 15.15 373 932 4.55 / 134.91 3 6
Average= 4.09
(KJ/cycle)

Cycle 31 GMT 17/ 5/2019 23: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 32 15.14 481 233 0.23 / 126.32 3 3
2 12 1170.48 3 15.25 1953 89 0.32 / 126.41 3 3
3 7 2003.48 30 14.88 2891 1291 1.61 / 127.70 3 3
4 13 1530.24 25 14.88 2356 876 2.49 / 128.58 3 3
5 13 824.84 25 15.00 1495 561 3.05 / 129.14 3 4
6 13 270.88 25 15.13 782 296 3.35 / 129.43 3 4
7 8 0.08 165 15.17 371 929 4.27 / 130.36 3 8
Average= 4.07
(KJ/cycle)

Cycle 30 GMT 8/ 5/2019 1: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 32 15.14 486 235 0.24 / 121.89 3 3
2 12 1165.44 3 15.24 1944 89 0.32 / 121.98 3 3
3 7 2002.16 30 14.89 2871 1282 1.61 / 123.26 3 3
4 13 1672.72 25 14.86 2516 935 2.54 / 124.19 3 3
5 13 914.72 25 14.98 1606 601 3.14 / 124.80 3 4
6 13 185.04 25 15.17 651 247 3.39 / 125.04 3 4
7 13 15.48 25 15.21 398 151 3.54 / 125.19 3 3
8 8 0.04 165 15.17 357 894 4.43 / 126.09 3 5
Average= 4.07
(KJ/cycle)

Cycle 29 GMT 28/ 4/2019 3:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 32 15.15 495 240 0.24 / 117.45 3 3
2 12 1161.64 3 15.26 1935 89 0.33 / 117.54 3 3
3 7 2002.36 30 14.88 2885 1288 1.62 / 118.83 3 4
4 13 1686.28 25 14.86 2545 945 2.56 / 119.77 3 4
5 13 783.40 25 15.02 1446 543 3.10 / 120.31 3 4
6 13 246.24 25 15.15 749 284 3.39 / 120.60 3 4
7 13 20.96 25 15.21 404 154 3.54 / 120.75 3 4
8 8 0.12 165 15.17 360 901 4.44 / 121.65 3 5
Average= 4.06
(KJ/cycle)

Cycle 28 GMT 18/ 4/2019 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 32 15.14 515 250 0.25 / 113.15 3 3
2 12 1170.52 3 15.27 1937 89 0.34 / 113.24 3 3
3 7 2004.52 30 14.89 2894 1293 1.63 / 114.53 3 4
4 13 1681.28 25 14.87 2536 943 2.57 / 115.48 3 4
5 13 780.36 25 15.02 1447 543 3.12 / 116.02 3 4
6 13 231.60 25 15.16 727 276 3.39 / 116.29 3 4
7 8 0.16 165 15.19 365 915 4.31 / 117.21 3 5
Average= 4.04
(KJ/cycle)

Cycle 27 GMT 8/ 4/2019 6:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 32 15.15 508 246 0.25 / 108.67 3 3
2 12 1169.00 3 15.26 1943 89 0.34 / 108.76 3 3
3 7 2000.84 30 14.91 2887 1291 1.63 / 110.05 3 3
4 13 1667.48 25 14.87 2528 940 2.57 / 110.99 3 3
5 13 803.12 25 15.02 1479 555 3.12 / 111.55 3 4
6 13 256.00 25 15.15 760 288 3.41 / 111.83 3 4
7 13 19.76 25 15.21 404 154 3.56 / 111.99 3 3
8 8 0.00 165 15.17 365 914 4.48 / 112.90 3 8
Average= 4.03
(KJ/cycle)

Cycle 26 GMT 29/ 3/2019 8:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 32 15.15 502 243 0.24 / 104.44 3 3
2 12 1159.72 3 15.26 1933 88 0.33 / 104.53 3 3
3 7 2003.48 30 14.90 2893 1293 1.63 / 105.83 3 3
4 13 1526.48 25 14.90 2358 878 2.50 / 106.70 3 3
5 13 855.84 25 15.01 1535 576 3.08 / 107.28 3 4
6 13 167.44 25 15.18 620 235 3.31 / 107.52 3 4
7 8 0.16 165 15.19 363 910 4.22 / 108.43 3 6
Average= 4.02
(KJ/cycle)

Cycle 25 GMT 19/ 3/2019 10:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 32 15.15 502 243 0.24 / 100.17 3 3
2 12 1170.20 3 15.27 1961 90 0.33 / 100.26 3 3
3 7 2007.12 30 14.90 2886 1290 1.62 / 101.55 3 3
4 13 1529.08 25 14.90 2357 878 2.50 / 102.43 3 3
5 13 821.84 25 15.02 1492 560 3.06 / 102.99 3 4
6 13 260.60 25 15.15 765 290 3.35 / 103.28 3 4
7 8 0.04 165 15.19 368 922 4.27 / 104.20 3 6
Average= 4.01
(KJ/cycle)

Cycle 24 GMT 9/ 3/2019 12:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 32 15.17 489 237 0.24 / 95.70 3 3
2 12 1162.08 3 15.26 1934 89 0.33 / 95.79 3 3
3 7 2004.12 30 14.92 2875 1287 1.61 / 97.08 3 3
4 13 1684.56 25 14.88 2532 942 2.55 / 98.02 3 3
5 13 815.96 25 15.03 1486 558 3.11 / 98.58 3 4
6 13 267.24 25 15.16 772 293 3.41 / 98.87 3 4
7 13 17.92 25 15.22 402 153 3.56 / 99.02 3 4
8 8 0.04 165 15.18 361 904 4.46 / 99.93 3 5
Average= 4.00
(KJ/cycle)

Cycle 23 GMT 27/ 2/2019 14:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 32 15.16 494 240 0.24 / 91.49 3 3
2 12 1312.84 3 15.23 2129 97 0.34 / 91.58 3 3
3 7 2007.40 30 14.90 2897 1295 1.63 / 92.88 3 3
4 13 1525.72 25 14.91 2360 880 2.51 / 93.76 3 3
5 13 830.80 25 15.02 1508 566 3.08 / 94.32 3 4
6 13 149.96 25 15.20 600 228 3.31 / 94.55 3 4
7 8 0.08 165 15.20 364 913 4.22 / 95.46 3 6
Average= 3.98
(KJ/cycle)

Cycle 22 GMT 17/ 2/2019 15:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 32 15.16 520 252 0.25 / 87.20 3 3
2 12 1169.36 3 15.28 1934 89 0.34 / 87.29 3 3
3 7 2006.84 30 14.91 2903 1299 1.64 / 88.59 3 3
4 13 1677.12 25 14.88 2533 942 2.58 / 89.53 3 4
5 13 771.92 25 15.05 1438 541 3.12 / 90.07 3 4
6 13 224.28 25 15.18 711 270 3.39 / 90.34 3 4
7 8 0.00 165 15.20 361 905 4.30 / 91.25 3 6
Average= 3.97
(KJ/cycle)

Cycle 21 GMT 7/ 2/2019 17: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 32 15.17 495 240 0.24 / 82.92 3 3
2 12 1190.16 3 15.27 1964 90 0.33 / 83.01 3 3
3 7 2003.36 30 14.91 2886 1291 1.62 / 84.30 3 3
4 13 1505.28 25 14.92 2330 869 2.49 / 85.17 3 3
5 13 811.08 25 15.04 1484 558 3.05 / 85.73 3 4
6 13 244.16 25 15.17 749 284 3.33 / 86.01 3 4
7 8 0.08 165 15.20 372 933 4.27 / 86.95 3 5
Average= 3.95
(KJ/cycle)

Cycle 20 GMT 28/ 1/2019 18:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 31 15.17 507 238 0.24 / 78.57 3 3
2 12 1173.88 3 15.29 1960 90 0.33 / 78.66 3 3
3 7 2002.56 30 14.94 2884 1293 1.62 / 79.95 3 3
4 13 1673.92 25 14.90 2524 940 2.56 / 80.89 3 3
5 13 937.88 25 15.02 1637 615 3.18 / 81.51 3 4
6 13 195.60 25 15.20 669 254 3.43 / 81.76 3 4
7 8 0.08 165 15.21 367 921 4.35 / 82.68 3 7
Average= 3.94
(KJ/cycle)

Cycle 19 GMT 18/ 1/2019 20:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 31 15.17 489 230 0.23 / 74.15 3 3
2 12 1175.60 3 15.29 1961 90 0.32 / 74.24 3 3
3 7 2002.72 30 14.93 2883 1291 1.61 / 75.53 3 3
4 13 1503.84 32 14.91 2308 1101 2.71 / 76.63 3 4
5 13 591.44 32 15.08 1196 577 3.29 / 77.21 3 5
6 13 44.96 32 15.23 441 215 3.50 / 77.42 3 4
7 8 0.12 165 15.20 363 910 4.41 / 78.33 3 10
Average= 3.92
(KJ/cycle)

Cycle 18 GMT 8/ 1/2019 22:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 31 15.17 489 230 0.23 / 69.72 3 3
2 12 1178.32 3 15.30 1961 90 0.32 / 69.81 3 3
3 7 2004.00 30 14.93 2896 1297 1.62 / 71.10 3 4
4 13 1511.28 32 14.91 2320 1107 2.72 / 72.21 3 4
5 13 600.60 32 15.09 1202 580 3.30 / 72.79 3 4
6 13 48.72 32 15.23 445 217 3.52 / 73.01 3 4
7 8 0.12 165 15.20 362 908 4.43 / 73.92 3 9
Average= 3.89
(KJ/cycle)

Cycle 17 GMT 30/12/2018 0:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 31 15.17 490 230 0.23 / 65.29 3 3
2 12 1182.48 3 15.30 1985 91 0.32 / 65.38 3 3
3 7 2002.60 30 14.93 2876 1288 1.61 / 66.67 3 3
4 13 1527.08 32 14.91 2344 1118 2.73 / 67.79 3 3
5 13 579.04 32 15.09 1180 570 3.30 / 68.36 3 4
6 13 41.72 32 15.24 440 215 3.51 / 68.57 3 4
7 8 0.00 165 15.20 365 915 4.43 / 69.49 3 6
Average= 3.86
(KJ/cycle)

Cycle 16 GMT 20/12/2018 2:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 31 15.19 493 232 0.23 / 60.86 3 3
2 12 1170.60 3 15.29 1947 89 0.32 / 60.95 3 3
3 7 2004.88 30 14.94 2878 1290 1.61 / 62.24 3 3
4 13 1504.72 32 14.92 2318 1107 2.72 / 63.35 3 3
5 13 580.16 32 15.10 1178 569 3.29 / 63.92 3 4
6 13 38.44 32 15.24 439 214 3.50 / 64.13 3 4
7 8 0.08 165 15.21 369 926 4.43 / 65.06 3 5
Average= 3.83
(KJ/cycle)

Cycle 15 GMT 10/12/2018 4:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 31 15.19 488 230 0.23 / 56.73 3 3
2 12 1164.48 3 15.30 1947 89 0.32 / 56.82 3 3
3 7 2003.40 30 14.94 2884 1293 1.61 / 58.11 3 3
4 13 1518.68 18 14.96 2351 633 2.24 / 58.75 3 3
5 13 1176.48 18 14.99 1941 524 2.77 / 59.27 3 4
6 13 457.16 18 15.14 1040 283 3.05 / 59.55 3 4
7 13 136.60 18 15.23 585 160 3.21 / 59.72 3 4
8 8 0.04 165 15.22 365 917 4.13 / 60.63 3 5
Average= 3.79
(KJ/cycle)

Cycle 14 GMT 30/11/2018 5:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 31 15.18 513 241 0.24 / 52.72 3 3
2 12 1166.52 3 15.31 1952 90 0.33 / 52.81 3 3
3 7 2003.60 30 14.94 2889 1295 1.63 / 54.11 3 3
4 13 1511.20 17 14.97 2349 598 2.22 / 54.70 3 3
5 13 1011.80 17 15.04 1742 445 2.67 / 55.15 3 4
6 13 490.80 17 15.14 1087 280 2.95 / 55.43 3 4
7 13 164.92 17 15.23 625 162 3.11 / 55.59 3 4
8 8 0.28 165 15.23 363 912 4.02 / 56.50 3 6
Average= 3.77
(KJ/cycle)

Cycle 13 GMT 20/11/2018 7: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 31 15.19 483 227 0.23 / 48.55 3 3
2 12 1170.96 3 15.30 1958 90 0.32 / 48.64 3 3
3 7 2003.16 30 14.95 2882 1293 1.61 / 49.93 3 3
4 13 1522.16 17 14.97 2368 603 2.21 / 50.53 3 3
5 13 1033.08 17 15.03 1775 454 2.67 / 50.99 3 4
6 13 531.76 17 15.13 1133 291 2.96 / 51.28 3 4
7 13 194.04 17 15.22 673 174 3.13 / 51.45 3 4
8 13 16.60 17 15.26 409 106 3.24 / 51.56 3 3
9 8 0.08 165 15.22 367 922 4.16 / 52.48 3 6
Average= 3.75
(KJ/cycle)

Cycle 12 GMT 10/11/2018 8:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.88 31 15.20 511 241 0.24 / 44.41 3 3
2 12 1172.28 3 15.31 1956 90 0.33 / 44.50 3 3
3 7 2001.28 30 14.95 2887 1295 1.63 / 45.79 3 3
4 13 1515.88 17 14.98 2354 599 2.22 / 46.39 3 3
5 13 1017.20 17 15.04 1752 448 2.67 / 46.84 3 4
6 13 517.76 17 15.14 1117 287 2.96 / 47.13 3 4
7 13 188.48 17 15.22 662 171 3.13 / 47.30 3 4
8 13 33.96 17 15.26 427 111 3.24 / 47.41 3 3
9 8 0.08 165 15.23 362 910 4.15 / 48.32 3 6
Average= 3.72
(KJ/cycle)

Cycle 11 GMT 31/10/2018 9:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 31 15.20 482 227 0.23 / 40.36 3 3
2 12 1169.16 3 15.31 1963 90 0.32 / 40.45 3 3
3 7 2004.52 30 14.96 2888 1296 1.61 / 41.74 3 3
4 13 1530.60 17 14.98 2374 605 2.22 / 42.35 3 3
5 13 1038.64 17 15.04 1769 452 2.67 / 42.80 3 3
6 13 516.84 17 15.14 1115 287 2.96 / 43.09 3 4
7 13 177.28 17 15.23 645 167 3.12 / 43.26 3 4
8 8 0.04 165 15.24 363 913 4.04 / 44.17 3 5
Average= 3.68
(KJ/cycle)

Cycle 10 GMT 21/10/2018 10:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.00 31 15.21 519 245 0.24 / 36.29 3 3
2 12 1172.52 3 15.31 1947 89 0.33 / 36.38 3 3
3 7 2000.52 30 14.95 2886 1294 1.63 / 37.68 3 3
4 13 1672.84 17 14.95 2542 646 2.27 / 38.32 3 3
5 13 989.36 17 15.05 1713 438 2.71 / 38.76 3 4
6 13 499.24 17 15.15 1097 283 3.00 / 39.04 3 4
7 13 166.44 17 15.23 635 164 3.16 / 39.21 3 4
8 8 0.08 165 15.24 367 923 4.08 / 40.13 3 8
Average= 3.65
(KJ/cycle)

Cycle 9 GMT 11/10/2018 11:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 31 15.21 494 233 0.23 / 32.29 3 3
2 12 1177.72 4 15.31 1947 119 0.35 / 32.40 3 3
3 7 1948.92 28 14.98 2826 1185 1.54 / 33.59 3 3
4 13 1461.40 18 15.00 2294 619 2.16 / 34.21 3 3
5 13 979.44 18 15.06 1711 464 2.62 / 34.67 3 4
6 13 466.80 18 15.16 1058 289 2.91 / 34.96 3 4
7 13 143.60 18 15.24 590 162 3.07 / 35.12 3 3
8 8 0.08 165 15.24 368 925 4.00 / 36.05 3 5
Average= 3.60
(KJ/cycle)

Cycle 8 GMT 1/10/2018 10:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 31 15.21 510 240 0.24 / 28.27 3 3
2 12 1170.16 4 15.32 1954 120 0.36 / 28.39 3 3
3 7 1970.24 28 14.98 2825 1185 1.55 / 29.58 3 3
4 13 1641.00 18 14.97 2490 671 2.22 / 30.25 3 3
5 13 960.44 18 15.07 1668 452 2.67 / 30.70 3 4
6 13 444.56 18 15.17 1023 279 2.95 / 30.98 3 4
7 13 132.28 18 15.25 584 160 3.11 / 31.14 3 4
8 8 0.16 165 15.24 363 913 4.02 / 32.05 3 5
Average= 3.56
(KJ/cycle)

Cycle 7 GMT 21/ 9/2018 10:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 30 15.21 472 215 0.22 / 24.20 3 3
2 3 1025.20 1 15.27 1784 27 0.24 / 24.23 3 3
3 12 2007.08 3 15.19 3010 137 0.38 / 24.37 3 3
4 7 2007.84 28 14.99 2875 1207 1.59 / 25.58 3 3
5 13 1500.80 18 15.00 2322 627 2.21 / 26.20 3 3
6 13 1015.00 18 15.06 1741 472 2.69 / 26.67 3 3
7 13 513.28 18 15.15 1118 305 2.99 / 26.98 3 4
8 13 99.48 18 15.26 522 143 3.13 / 27.12 3 3
9 8 0.12 165 15.25 361 908 4.04 / 28.03 3 6
Average= 3.50
(KJ/cycle)

Cycle 6 GMT 11/ 9/2018 12:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 29 15.21 477 210 0.21 / 20.01 3 3
2 10 1000.64 2 15.20 1741 53 0.26 / 20.06 3 3
3 3 965.12 -1 15.54 0 0 0.05 / 20.06 3 3
4 7 2006.04 40 14.93 2862 1709 1.97 / 21.77 3 3
5 13 1320.40 18 15.02 2107 570 2.54 / 22.34 3 4
6 13 808.96 18 15.10 1488 404 2.95 / 22.75 3 4
7 13 301.96 18 15.20 826 226 3.17 / 22.97 3 4
8 13 31.44 18 15.28 417 115 3.29 / 23.09 3 3
9 8 0.16 165 15.24 358 900 4.19 / 23.99 3 5
Average= 3.43
(KJ/cycle)

Cycle 5 GMT 1/ 9/2018 14:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 29 15.23 463 204 0.20 / 15.84 3 3
2 3 1020.56 1 15.30 1778 27 0.23 / 15.87 3 3
3 7 2004.20 40 14.94 2866 1713 1.94 / 17.58 3 3
4 13 1316.64 18 15.03 2090 565 2.51 / 18.15 3 4
5 13 822.88 18 15.10 1500 408 2.92 / 18.56 3 4
6 13 314.36 18 15.20 841 230 3.15 / 18.79 3 4
7 13 36.52 18 15.28 431 119 3.27 / 18.90 3 3
8 8 0.08 165 15.24 357 898 4.16 / 19.80 3 5
Average= 3.30
(KJ/cycle)

Cycle 4 GMT 22/ 8/2018 14:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 29 15.23 485 214 0.21 / 12.34 3 3
2 7 1507.84 40 15.06 2276 1371 1.59 / 13.71 3 3
3 13 1204.04 18 15.08 1949 529 2.11 / 14.24 3 3
4 13 689.48 18 15.15 1318 359 2.47 / 14.59 3 4
5 13 198.96 18 15.25 670 184 2.66 / 14.78 3 3
6 8 0.12 165 15.27 341 859 3.52 / 15.64 3 5
Average= 3.13
(KJ/cycle)

Cycle 3 GMT 21/ 8/2018 14:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 29 15.24 461 204 0.20 / 8.46 3 3
2 7 1508.00 74 14.98 2266 2512 2.72 / 10.97 3 3
3 13 277.76 18 15.24 730 200 2.92 / 11.17 3 4
4 13 61.04 18 15.29 421 116 3.03 / 11.29 3 3
5 8 0.08 165 15.27 330 831 3.86 / 12.12 3 5
Average= 3.03
(KJ/cycle)

Cycle 2 GMT 20/ 8/2018 14:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 30 15.28 427 196 0.20 / 4.72 3 3
2 3 941.40 -1 15.57 0 0 0.00 / 4.72 3 3
3 7 1509.24 74 15.00 2212 2455 2.65 / 7.18 3 3
4 13 274.68 18 15.25 718 197 2.85 / 7.38 3 4
5 13 30.16 18 15.31 351 97 2.94 / 7.47 3 3
6 8 0.20 165 15.28 311 784 3.73 / 8.26 3 5
Average= 2.75
(KJ/cycle)

Cycle 1 GMT 19/ 8/2018 15: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.48 30 15.49 406 189 0.19 / 1.61 3 3
2 3 944.24 -1 15.60 0 0 0.00 / 1.61 3 3
3 7 993.88 74 15.17 1597 1793 1.98 / 3.40 3 4
4 8 0.08 240 15.33 306 1126 3.11 / 4.53 3 13
Average= 2.26
(KJ/cycle)

Cycle 0 GMT 19/ 8/2018 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 84.28 22 15.63 362 124 0.12 / 0.12 3 3
2 7 99.32 74 15.60 373 431 0.56 / 0.56 3 3
3 8 0.32 240 15.56 232 866 1.42 / 1.42 3 6
Average= 1.42
(KJ/cycle)