SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 30 | 14.91 | 483 | 216 | 0.22 / 1163.50 | 2 | 2 |
2 | 7 | 2002.84 | 44 | 14.13 | 2964 | 1843 | 2.06 / 1165.35 | 2 | 2 |
3 | 13 | 1738.04 | 18 | 14.19 | 2689 | 687 | 2.75 / 1166.03 | 2 | 2 |
4 | 13 | 1310.64 | 18 | 14.31 | 2087 | 538 | 3.28 / 1166.57 | 2 | 2 |
5 | 13 | 741.48 | 18 | 14.58 | 1363 | 358 | 3.64 / 1166.93 | 2 | 2 |
6 | 13 | 81.60 | 18 | 14.93 | 459 | 123 | 3.76 / 1167.05 | 2 | 2 |
7 | 8 | -1.40 | 165 | 14.94 | 307 | 757 | 4.52 / 1167.81 | 2 | 2 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 30 | 14.90 | 507 | 227 | 0.23 / 1159.06 | 2 | 2 |
2 | 7 | 2007.96 | 44 | 14.12 | 2995 | 1861 | 2.09 / 1160.92 | 2 | 2 |
3 | 13 | 1745.60 | 18 | 14.20 | 2656 | 679 | 2.77 / 1161.60 | 2 | 2 |
4 | 13 | 1173.00 | 18 | 14.37 | 1921 | 497 | 3.26 / 1162.09 | 2 | 2 |
5 | 13 | 616.72 | 18 | 14.64 | 1206 | 318 | 3.58 / 1162.41 | 2 | 2 |
6 | 13 | 89.76 | 18 | 14.92 | 463 | 124 | 3.71 / 1162.54 | 2 | 2 |
7 | 8 | -1.36 | 165 | 14.94 | 305 | 752 | 4.46 / 1163.29 | 2 | 2 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 30 | 14.90 | 506 | 226 | 0.23 / 1154.60 | 2 | 2 |
2 | 7 | 2004.96 | 44 | 14.11 | 2988 | 1855 | 2.08 / 1156.46 | 2 | 2 |
3 | 13 | 1614.32 | 18 | 14.23 | 2512 | 643 | 2.72 / 1157.10 | 2 | 2 |
4 | 13 | 1209.08 | 18 | 14.35 | 1979 | 511 | 3.24 / 1157.61 | 2 | 2 |
5 | 13 | 652.40 | 18 | 14.62 | 1252 | 329 | 3.57 / 1157.94 | 2 | 2 |
6 | 13 | 107.92 | 18 | 14.91 | 491 | 132 | 3.70 / 1158.07 | 2 | 2 |
7 | 8 | -1.12 | 165 | 14.93 | 307 | 756 | 4.45 / 1158.83 | 2 | 2 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 30 | 14.89 | 499 | 223 | 0.22 / 1150.07 | 2 | 2 |
2 | 7 | 2002.88 | 44 | 14.13 | 2961 | 1841 | 2.06 / 1151.91 | 2 | 2 |
3 | 13 | 1735.36 | 18 | 14.20 | 2699 | 690 | 2.75 / 1152.60 | 2 | 2 |
4 | 13 | 1308.76 | 18 | 14.31 | 2100 | 541 | 3.29 / 1153.14 | 2 | 2 |
5 | 13 | 738.92 | 18 | 14.57 | 1363 | 357 | 3.65 / 1153.50 | 2 | 2 |
6 | 13 | 80.84 | 18 | 14.93 | 453 | 122 | 3.77 / 1153.62 | 2 | 2 |
7 | 8 | -1.44 | 165 | 14.94 | 308 | 759 | 4.53 / 1154.38 | 2 | 2 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 30 | 14.89 | 496 | 222 | 0.22 / 1145.51 | 2 | 2 |
2 | 7 | 2010.76 | 44 | 14.11 | 3009 | 1868 | 2.09 / 1147.38 | 2 | 2 |
3 | 13 | 1739.04 | 18 | 14.20 | 2647 | 677 | 2.77 / 1148.06 | 2 | 2 |
4 | 13 | 1316.12 | 18 | 14.31 | 2116 | 545 | 3.31 / 1148.60 | 2 | 2 |
5 | 13 | 729.36 | 18 | 14.57 | 1362 | 357 | 3.67 / 1148.96 | 2 | 2 |
6 | 13 | 73.40 | 18 | 14.93 | 443 | 119 | 3.79 / 1149.08 | 2 | 2 |
7 | 8 | -1.24 | 165 | 14.93 | 310 | 764 | 4.55 / 1149.84 | 2 | 2 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 30 | 14.89 | 503 | 225 | 0.22 / 1141.06 | 2 | 2 |
2 | 7 | 2004.20 | 44 | 14.11 | 3009 | 1868 | 2.09 / 1142.93 | 2 | 2 |
3 | 13 | 1736.08 | 18 | 14.19 | 2665 | 681 | 2.77 / 1143.61 | 2 | 2 |
4 | 13 | 1178.80 | 18 | 14.37 | 1949 | 504 | 3.28 / 1144.12 | 2 | 2 |
5 | 13 | 615.52 | 18 | 14.64 | 1181 | 311 | 3.59 / 1144.43 | 2 | 2 |
6 | 13 | 45.92 | 18 | 14.94 | 385 | 104 | 3.69 / 1144.53 | 2 | 2 |
7 | 8 | -1.20 | 165 | 14.93 | 309 | 761 | 4.45 / 1145.29 | 2 | 2 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 28 | 14.89 | 489 | 204 | 0.20 / 1136.51 | 2 | 2 |
2 | 10 | 1005.72 | 3 | 14.72 | 1824 | 81 | 0.28 / 1136.59 | 2 | 2 |
3 | 7 | 2009.12 | 44 | 14.11 | 2992 | 1858 | 2.14 / 1138.45 | 2 | 2 |
4 | 13 | 1747.24 | 18 | 14.19 | 2647 | 676 | 2.82 / 1139.13 | 2 | 2 |
5 | 13 | 1173.92 | 18 | 14.37 | 1944 | 503 | 3.32 / 1139.63 | 2 | 2 |
6 | 13 | 628.00 | 18 | 14.63 | 1221 | 322 | 3.64 / 1139.95 | 2 | 2 |
7 | 13 | 94.40 | 18 | 14.91 | 477 | 128 | 3.77 / 1140.08 | 2 | 2 |
8 | 8 | -1.20 | 165 | 14.92 | 309 | 761 | 4.53 / 1140.84 | 2 | 2 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 30 | 14.87 | 485 | 216 | 0.22 / 1132.09 | 2 | 2 |
2 | 3 | 928.24 | -1 | 15.30 | 0 | 0 | 0.00 / 1132.09 | 2 | 2 |
3 | 3 | 968.76 | -1 | 15.33 | 0 | 0 | 0.00 / 1132.09 | 2 | 2 |
4 | 7 | 2010.28 | 44 | 14.10 | 2998 | 1860 | 2.08 / 1133.95 | 2 | 2 |
5 | 13 | 1614.80 | 18 | 14.22 | 2504 | 641 | 2.72 / 1134.59 | 2 | 2 |
6 | 13 | 1202.48 | 18 | 14.35 | 1971 | 509 | 3.23 / 1135.10 | 2 | 2 |
7 | 13 | 650.76 | 18 | 14.61 | 1250 | 329 | 3.56 / 1135.43 | 2 | 2 |
8 | 13 | 105.36 | 18 | 14.90 | 489 | 131 | 3.69 / 1135.56 | 2 | 2 |
9 | 8 | -1.24 | 165 | 14.92 | 304 | 748 | 4.43 / 1136.31 | 2 | 2 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 30 | 14.88 | 498 | 222 | 0.22 / 1127.68 | 2 | 2 |
2 | 7 | 2008.80 | 44 | 14.12 | 2955 | 1836 | 2.06 / 1129.51 | 2 | 2 |
3 | 13 | 1610.32 | 18 | 14.23 | 2515 | 644 | 2.70 / 1130.16 | 2 | 2 |
4 | 13 | 1201.76 | 18 | 14.36 | 1940 | 501 | 3.20 / 1130.66 | 2 | 2 |
5 | 13 | 640.36 | 18 | 14.62 | 1221 | 321 | 3.53 / 1130.98 | 2 | 2 |
6 | 13 | 100.00 | 18 | 14.90 | 487 | 131 | 3.66 / 1131.11 | 2 | 2 |
7 | 8 | -1.04 | 165 | 14.92 | 309 | 761 | 4.42 / 1131.87 | 2 | 2 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 30 | 14.87 | 491 | 219 | 0.22 / 1123.24 | 2 | 2 |
2 | 7 | 2004.80 | 44 | 14.11 | 3000 | 1863 | 2.08 / 1125.10 | 2 | 2 |
3 | 13 | 1612.24 | 18 | 14.22 | 2533 | 648 | 2.73 / 1125.75 | 2 | 2 |
4 | 13 | 1204.72 | 18 | 14.34 | 1978 | 511 | 3.24 / 1126.26 | 2 | 2 |
5 | 13 | 623.88 | 18 | 14.61 | 1219 | 321 | 3.56 / 1126.58 | 2 | 2 |
6 | 13 | 97.84 | 18 | 14.90 | 477 | 128 | 3.69 / 1126.71 | 2 | 2 |
7 | 8 | -1.12 | 165 | 14.92 | 305 | 751 | 4.44 / 1127.46 | 2 | 2 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 30 | 14.88 | 505 | 225 | 0.23 / 1118.70 | 2 | 2 |
2 | 7 | 2003.52 | 44 | 14.12 | 2969 | 1845 | 2.07 / 1120.55 | 2 | 2 |
3 | 13 | 1872.72 | 18 | 14.16 | 2855 | 728 | 2.80 / 1121.27 | 2 | 2 |
4 | 13 | 1296.36 | 18 | 14.33 | 2016 | 520 | 3.32 / 1121.79 | 2 | 2 |
5 | 13 | 725.92 | 18 | 14.57 | 1341 | 352 | 3.67 / 1122.14 | 2 | 2 |
6 | 13 | 64.68 | 18 | 14.92 | 425 | 114 | 3.78 / 1122.26 | 2 | 2 |
7 | 8 | -1.12 | 165 | 14.92 | 308 | 758 | 4.54 / 1123.02 | 2 | 2 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 30 | 14.89 | 496 | 222 | 0.22 / 1114.03 | 2 | 2 |
2 | 7 | 2007.08 | 44 | 14.11 | 2989 | 1856 | 2.08 / 1115.88 | 2 | 2 |
3 | 13 | 1744.48 | 18 | 14.19 | 2698 | 689 | 2.77 / 1116.57 | 2 | 2 |
4 | 13 | 1177.32 | 18 | 14.37 | 1928 | 499 | 3.27 / 1117.07 | 2 | 2 |
5 | 13 | 750.04 | 18 | 14.56 | 1362 | 357 | 3.62 / 1117.43 | 2 | 2 |
6 | 13 | 79.44 | 18 | 14.91 | 435 | 117 | 3.74 / 1117.54 | 2 | 2 |
7 | 8 | -1.04 | 165 | 14.91 | 313 | 770 | 4.51 / 1118.31 | 2 | 2 |
8 | 14 | -1.04 | 35 | 14.89 | 311 | 162 | 4.67 / 1118.48 | 2 | 2 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 30 | 14.88 | 504 | 225 | 0.22 / 1109.57 | 2 | 2 |
2 | 7 | 2006.36 | 44 | 14.12 | 2941 | 1827 | 2.05 / 1111.39 | 2 | 2 |
3 | 13 | 1606.84 | 18 | 14.23 | 2528 | 648 | 2.70 / 1112.04 | 2 | 2 |
4 | 13 | 1195.92 | 18 | 14.34 | 1980 | 511 | 3.21 / 1112.55 | 2 | 2 |
5 | 13 | 765.36 | 18 | 14.54 | 1406 | 368 | 3.58 / 1112.92 | 2 | 2 |
6 | 13 | 91.08 | 18 | 14.90 | 472 | 127 | 3.71 / 1113.05 | 2 | 2 |
7 | 8 | -0.96 | 165 | 14.91 | 308 | 758 | 4.46 / 1113.80 | 2 | 2 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 30 | 14.88 | 500 | 223 | 0.22 / 1105.15 | 2 | 2 |
2 | 7 | 2005.04 | 44 | 14.11 | 2986 | 1854 | 2.08 / 1107.00 | 2 | 2 |
3 | 13 | 1598.92 | 18 | 14.22 | 2476 | 634 | 2.71 / 1107.64 | 2 | 2 |
4 | 13 | 1186.52 | 18 | 14.35 | 1935 | 500 | 3.21 / 1108.14 | 2 | 2 |
5 | 13 | 617.28 | 18 | 14.61 | 1215 | 320 | 3.53 / 1108.46 | 2 | 2 |
6 | 13 | 87.88 | 18 | 14.90 | 469 | 126 | 3.66 / 1108.58 | 2 | 2 |
7 | 8 | -1.16 | 165 | 14.91 | 309 | 760 | 4.42 / 1109.34 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 29 | 14.88 | 515 | 222 | 0.22 / 1100.75 | 2 | 2 |
2 | 3 | 1031.40 | 1 | 14.90 | 1896 | 28 | 0.25 / 1100.77 | 2 | 2 |
3 | 7 | 2002.72 | 44 | 14.10 | 3005 | 1864 | 2.11 / 1102.64 | 2 | 2 |
4 | 13 | 1732.40 | 18 | 14.19 | 2635 | 673 | 2.79 / 1103.31 | 2 | 2 |
5 | 13 | 1166.08 | 18 | 14.36 | 1907 | 493 | 3.28 / 1103.80 | 2 | 2 |
6 | 13 | 485.12 | 18 | 14.69 | 1005 | 266 | 3.55 / 1104.07 | 2 | 2 |
7 | 13 | 24.24 | 18 | 14.93 | 351 | 94 | 3.64 / 1104.16 | 2 | 2 |
8 | 8 | -1.12 | 165 | 14.91 | 309 | 760 | 4.40 / 1104.93 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 30 | 14.88 | 482 | 215 | 0.22 / 1096.33 | 2 | 2 |
2 | 3 | 973.60 | -1 | 15.30 | 0 | 0 | 0.00 / 1096.33 | 2 | 2 |
3 | 7 | 2005.60 | 44 | 14.10 | 3000 | 1861 | 2.08 / 1098.19 | 2 | 2 |
4 | 13 | 1599.20 | 18 | 14.22 | 2495 | 639 | 2.71 / 1098.83 | 2 | 2 |
5 | 13 | 1184.56 | 18 | 14.35 | 1936 | 500 | 3.22 / 1099.33 | 2 | 2 |
6 | 13 | 627.52 | 18 | 14.62 | 1189 | 313 | 3.53 / 1099.64 | 2 | 2 |
7 | 13 | 93.60 | 18 | 14.89 | 463 | 124 | 3.65 / 1099.76 | 2 | 2 |
8 | 8 | -1.20 | 165 | 14.91 | 309 | 760 | 4.41 / 1100.52 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 30 | 14.88 | 489 | 218 | 0.22 / 1091.83 | 2 | 2 |
2 | 7 | 2005.16 | 44 | 14.12 | 2960 | 1839 | 2.06 / 1093.67 | 2 | 2 |
3 | 13 | 1735.88 | 18 | 14.20 | 2644 | 676 | 2.73 / 1094.34 | 2 | 2 |
4 | 13 | 1306.44 | 18 | 14.29 | 2105 | 541 | 3.27 / 1094.89 | 2 | 2 |
5 | 13 | 734.64 | 18 | 14.55 | 1368 | 358 | 3.63 / 1095.24 | 2 | 2 |
6 | 13 | 79.12 | 18 | 14.90 | 446 | 120 | 3.75 / 1095.36 | 2 | 2 |
7 | 8 | -1.04 | 165 | 14.91 | 304 | 748 | 4.50 / 1096.11 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 30 | 14.89 | 511 | 228 | 0.23 / 1087.38 | 2 | 2 |
2 | 7 | 2008.08 | 44 | 14.11 | 2963 | 1840 | 2.07 / 1089.21 | 2 | 2 |
3 | 13 | 1734.84 | 18 | 14.19 | 2676 | 684 | 2.75 / 1089.90 | 2 | 2 |
4 | 13 | 1170.04 | 18 | 14.37 | 1883 | 487 | 3.24 / 1090.39 | 2 | 2 |
5 | 13 | 758.20 | 18 | 14.54 | 1386 | 363 | 3.60 / 1090.75 | 2 | 2 |
6 | 13 | 40.96 | 18 | 14.92 | 384 | 103 | 3.70 / 1090.85 | 2 | 2 |
7 | 8 | -1.40 | 165 | 14.91 | 309 | 760 | 4.46 / 1091.61 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 30 | 14.88 | 479 | 214 | 0.21 / 1082.91 | 2 | 2 |
2 | 7 | 2003.08 | 44 | 14.11 | 3000 | 1863 | 2.08 / 1084.77 | 2 | 2 |
3 | 13 | 1725.84 | 18 | 14.19 | 2654 | 678 | 2.75 / 1085.45 | 2 | 2 |
4 | 13 | 1180.88 | 18 | 14.36 | 1936 | 500 | 3.25 / 1085.95 | 2 | 2 |
5 | 13 | 613.48 | 18 | 14.61 | 1199 | 315 | 3.57 / 1086.27 | 2 | 2 |
6 | 13 | 84.88 | 18 | 14.89 | 454 | 122 | 3.69 / 1086.39 | 2 | 2 |
7 | 8 | -1.04 | 165 | 14.91 | 308 | 758 | 4.45 / 1087.15 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 30 | 14.89 | 487 | 218 | 0.22 / 1078.48 | 2 | 2 |
2 | 7 | 2007.08 | 44 | 14.11 | 2999 | 1862 | 2.08 / 1080.35 | 2 | 2 |
3 | 13 | 1614.68 | 18 | 14.22 | 2531 | 648 | 2.73 / 1080.99 | 2 | 2 |
4 | 13 | 1195.32 | 18 | 14.35 | 1945 | 502 | 3.23 / 1081.50 | 2 | 2 |
5 | 13 | 635.24 | 18 | 14.60 | 1221 | 321 | 3.55 / 1081.82 | 2 | 2 |
6 | 13 | 102.24 | 18 | 14.88 | 484 | 130 | 3.68 / 1081.95 | 2 | 2 |
7 | 8 | -1.12 | 165 | 14.91 | 305 | 750 | 4.43 / 1082.70 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 30 | 14.89 | 492 | 220 | 0.22 / 1073.96 | 2 | 2 |
2 | 7 | 2005.92 | 45 | 14.11 | 2985 | 1895 | 2.12 / 1075.86 | 2 | 2 |
3 | 13 | 1743.40 | 18 | 14.20 | 2644 | 676 | 2.79 / 1076.54 | 2 | 2 |
4 | 13 | 1317.76 | 18 | 14.29 | 2115 | 544 | 3.33 / 1077.08 | 2 | 2 |
5 | 13 | 613.60 | 18 | 14.62 | 1192 | 314 | 3.65 / 1077.39 | 2 | 2 |
6 | 13 | 91.36 | 18 | 14.89 | 463 | 124 | 3.77 / 1077.52 | 2 | 2 |
7 | 8 | -1.12 | 165 | 14.91 | 305 | 750 | 4.52 / 1078.27 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 30 | 14.89 | 498 | 222 | 0.22 / 1069.54 | 2 | 2 |
2 | 7 | 2003.44 | 44 | 14.12 | 2968 | 1844 | 2.07 / 1071.39 | 2 | 2 |
3 | 13 | 1741.44 | 18 | 14.19 | 2676 | 684 | 2.75 / 1072.07 | 2 | 2 |
4 | 13 | 1186.56 | 18 | 14.35 | 1921 | 496 | 3.25 / 1072.57 | 2 | 2 |
5 | 13 | 624.88 | 18 | 14.60 | 1215 | 319 | 3.57 / 1072.89 | 2 | 2 |
6 | 13 | 53.16 | 18 | 14.91 | 395 | 106 | 3.67 / 1072.99 | 2 | 2 |
7 | 8 | -1.28 | 165 | 14.91 | 306 | 753 | 4.42 / 1073.74 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 30 | 14.89 | 485 | 217 | 0.22 / 1065.08 | 2 | 2 |
2 | 7 | 2002.60 | 44 | 14.11 | 2977 | 1848 | 2.06 / 1066.93 | 2 | 2 |
3 | 13 | 1599.28 | 18 | 14.22 | 2503 | 641 | 2.71 / 1067.57 | 2 | 2 |
4 | 13 | 1316.12 | 18 | 14.29 | 2104 | 541 | 3.25 / 1068.11 | 2 | 2 |
5 | 13 | 591.52 | 18 | 14.62 | 1169 | 308 | 3.55 / 1068.42 | 2 | 2 |
6 | 13 | 154.40 | 18 | 14.85 | 569 | 152 | 3.71 / 1068.57 | 2 | 2 |
7 | 8 | -1.12 | 165 | 14.91 | 306 | 753 | 4.46 / 1069.32 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 30 | 14.90 | 495 | 221 | 0.22 / 1060.62 | 2 | 2 |
2 | 7 | 2009.68 | 44 | 14.11 | 2985 | 1853 | 2.07 / 1062.47 | 2 | 2 |
3 | 13 | 1741.16 | 18 | 14.19 | 2655 | 678 | 2.75 / 1063.15 | 2 | 2 |
4 | 13 | 1307.92 | 18 | 14.30 | 2110 | 543 | 3.30 / 1063.69 | 2 | 2 |
5 | 13 | 605.92 | 18 | 14.62 | 1177 | 310 | 3.61 / 1064.00 | 2 | 2 |
6 | 13 | 83.12 | 18 | 14.89 | 454 | 122 | 3.73 / 1064.12 | 2 | 2 |
7 | 8 | -1.20 | 165 | 14.91 | 300 | 738 | 4.47 / 1064.86 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 30 | 14.88 | 492 | 220 | 0.22 / 1056.15 | 2 | 2 |
2 | 7 | 2003.92 | 44 | 14.12 | 2988 | 1856 | 2.08 / 1058.01 | 2 | 2 |
3 | 13 | 1730.32 | 18 | 14.19 | 2657 | 679 | 2.75 / 1058.69 | 2 | 2 |
4 | 13 | 1299.36 | 18 | 14.29 | 2088 | 537 | 3.29 / 1059.22 | 2 | 2 |
5 | 13 | 579.28 | 18 | 14.63 | 1157 | 305 | 3.60 / 1059.53 | 2 | 2 |
6 | 13 | 79.52 | 18 | 14.90 | 447 | 120 | 3.72 / 1059.65 | 2 | 2 |
7 | 8 | -1.24 | 165 | 14.91 | 304 | 748 | 4.46 / 1060.40 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 30 | 14.89 | 474 | 212 | 0.21 / 1051.65 | 2 | 2 |
2 | 7 | 2004.92 | 44 | 14.09 | 3024 | 1875 | 2.09 / 1053.53 | 2 | 2 |
3 | 13 | 1738.08 | 18 | 14.19 | 2666 | 681 | 2.77 / 1054.21 | 2 | 2 |
4 | 13 | 1166.28 | 18 | 14.35 | 1921 | 496 | 3.26 / 1054.70 | 2 | 2 |
5 | 13 | 752.92 | 18 | 14.53 | 1386 | 362 | 3.63 / 1055.07 | 2 | 2 |
6 | 13 | 74.92 | 18 | 14.89 | 440 | 118 | 3.74 / 1055.18 | 2 | 2 |
7 | 8 | -1.16 | 165 | 14.91 | 304 | 748 | 4.49 / 1055.93 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 30 | 14.89 | 483 | 216 | 0.22 / 1047.19 | 2 | 2 |
2 | 7 | 2009.52 | 44 | 14.12 | 2965 | 1842 | 2.06 / 1049.03 | 2 | 2 |
3 | 13 | 1748.12 | 18 | 14.18 | 2697 | 688 | 2.75 / 1049.72 | 2 | 2 |
4 | 13 | 1310.48 | 18 | 14.29 | 2114 | 544 | 3.29 / 1050.26 | 2 | 2 |
5 | 13 | 597.56 | 18 | 14.60 | 1181 | 310 | 3.60 / 1050.57 | 2 | 2 |
6 | 13 | 46.56 | 18 | 14.91 | 396 | 106 | 3.71 / 1050.68 | 2 | 2 |
7 | 8 | -1.12 | 165 | 14.91 | 309 | 760 | 4.47 / 1051.44 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 30 | 14.90 | 482 | 215 | 0.22 / 1042.85 | 2 | 2 |
2 | 7 | 2005.32 | 44 | 14.13 | 2956 | 1838 | 2.05 / 1044.69 | 2 | 2 |
3 | 13 | 1594.12 | 18 | 14.23 | 2491 | 638 | 2.69 / 1045.33 | 2 | 2 |
4 | 13 | 1189.56 | 18 | 14.33 | 1952 | 503 | 3.19 / 1045.83 | 2 | 2 |
5 | 13 | 482.44 | 18 | 14.66 | 1028 | 271 | 3.47 / 1046.11 | 2 | 2 |
6 | 13 | 52.64 | 18 | 14.90 | 402 | 108 | 3.57 / 1046.21 | 2 | 2 |
7 | 8 | -1.16 | 165 | 14.90 | 309 | 760 | 4.33 / 1046.97 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 30 | 14.87 | 489 | 218 | 0.22 / 1038.37 | 2 | 2 |
2 | 7 | 2002.08 | 44 | 14.12 | 2934 | 1823 | 2.04 / 1040.19 | 2 | 2 |
3 | 13 | 1739.56 | 18 | 14.19 | 2666 | 681 | 2.72 / 1040.87 | 2 | 2 |
4 | 13 | 1312.40 | 18 | 14.29 | 2131 | 548 | 3.27 / 1041.42 | 2 | 2 |
5 | 13 | 606.08 | 18 | 14.60 | 1194 | 314 | 3.58 / 1041.74 | 2 | 2 |
6 | 13 | 87.04 | 18 | 14.88 | 469 | 126 | 3.71 / 1041.86 | 2 | 2 |
7 | 8 | -1.12 | 165 | 14.90 | 316 | 777 | 4.49 / 1042.64 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 30 | 14.89 | 501 | 224 | 0.22 / 1033.90 | 2 | 2 |
2 | 7 | 2004.20 | 44 | 14.11 | 2985 | 1853 | 2.08 / 1035.75 | 2 | 2 |
3 | 13 | 1736.28 | 18 | 14.21 | 2641 | 676 | 2.75 / 1036.42 | 2 | 2 |
4 | 13 | 1184.40 | 18 | 14.34 | 1955 | 505 | 3.26 / 1036.93 | 2 | 2 |
5 | 13 | 620.96 | 18 | 14.60 | 1209 | 318 | 3.57 / 1037.25 | 2 | 2 |
6 | 13 | 185.76 | 18 | 14.81 | 614 | 164 | 3.74 / 1037.41 | 2 | 2 |
7 | 8 | -1.08 | 165 | 14.90 | 302 | 742 | 4.48 / 1038.15 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 30 | 14.89 | 486 | 217 | 0.22 / 1029.47 | 2 | 2 |
2 | 7 | 2004.24 | 44 | 14.13 | 2945 | 1831 | 2.05 / 1031.30 | 2 | 2 |
3 | 13 | 1597.88 | 18 | 14.23 | 2482 | 636 | 2.68 / 1031.94 | 2 | 2 |
4 | 13 | 1328.24 | 18 | 14.28 | 2093 | 538 | 3.22 / 1032.47 | 2 | 2 |
5 | 13 | 741.16 | 18 | 14.53 | 1373 | 359 | 3.58 / 1032.83 | 2 | 2 |
6 | 13 | 43.84 | 18 | 14.91 | 377 | 101 | 3.68 / 1032.93 | 2 | 2 |
7 | 8 | -1.20 | 165 | 14.91 | 300 | 738 | 4.42 / 1033.67 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 30 | 14.89 | 493 | 220 | 0.22 / 1024.95 | 2 | 2 |
2 | 7 | 2005.56 | 44 | 14.12 | 2970 | 1845 | 2.07 / 1026.80 | 2 | 2 |
3 | 13 | 1732.92 | 18 | 14.20 | 2665 | 681 | 2.75 / 1027.48 | 2 | 2 |
4 | 13 | 1308.16 | 18 | 14.28 | 2105 | 541 | 3.29 / 1028.02 | 2 | 2 |
5 | 13 | 732.76 | 18 | 14.54 | 1364 | 357 | 3.64 / 1028.38 | 2 | 2 |
6 | 13 | 71.00 | 18 | 14.89 | 436 | 117 | 3.76 / 1028.49 | 2 | 2 |
7 | 8 | -1.12 | 165 | 14.91 | 308 | 758 | 4.52 / 1029.25 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 30 | 14.88 | 476 | 212 | 0.21 / 1020.62 | 2 | 2 |
2 | 7 | 2002.44 | 44 | 14.13 | 2979 | 1852 | 2.06 / 1022.48 | 2 | 2 |
3 | 13 | 1606.64 | 18 | 14.23 | 2507 | 642 | 2.71 / 1023.12 | 2 | 2 |
4 | 13 | 1083.56 | 18 | 14.38 | 1812 | 469 | 3.18 / 1023.59 | 2 | 2 |
5 | 13 | 544.84 | 18 | 14.63 | 1117 | 294 | 3.47 / 1023.88 | 2 | 2 |
6 | 13 | 39.40 | 18 | 14.91 | 369 | 99 | 3.57 / 1023.98 | 2 | 2 |
7 | 8 | -1.00 | 165 | 14.91 | 306 | 753 | 4.32 / 1024.73 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 30 | 14.87 | 489 | 218 | 0.22 / 1016.10 | 2 | 2 |
2 | 7 | 2012.52 | 45 | 14.12 | 2981 | 1894 | 2.11 / 1017.99 | 2 | 2 |
3 | 13 | 1745.64 | 18 | 14.20 | 2657 | 679 | 2.79 / 1018.67 | 2 | 2 |
4 | 13 | 1189.72 | 18 | 14.34 | 1959 | 506 | 3.30 / 1019.18 | 2 | 2 |
5 | 13 | 762.88 | 18 | 14.52 | 1393 | 364 | 3.66 / 1019.54 | 2 | 2 |
6 | 13 | 78.68 | 18 | 14.88 | 441 | 118 | 3.78 / 1019.66 | 2 | 2 |
7 | 8 | -1.04 | 165 | 14.89 | 306 | 752 | 4.53 / 1020.41 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 30 | 14.87 | 480 | 214 | 0.21 / 1011.63 | 2 | 2 |
2 | 7 | 2010.80 | 44 | 14.13 | 2955 | 1837 | 2.05 / 1013.46 | 2 | 2 |
3 | 13 | 1756.48 | 18 | 14.19 | 2692 | 688 | 2.74 / 1014.15 | 2 | 2 |
4 | 13 | 1321.32 | 18 | 14.29 | 2115 | 544 | 3.28 / 1014.69 | 2 | 2 |
5 | 13 | 629.28 | 18 | 14.60 | 1214 | 319 | 3.60 / 1015.01 | 2 | 2 |
6 | 13 | 51.12 | 18 | 14.90 | 396 | 106 | 3.71 / 1015.12 | 2 | 2 |
7 | 8 | -0.88 | 165 | 14.90 | 309 | 760 | 4.47 / 1015.88 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 30 | 14.88 | 481 | 215 | 0.21 / 1007.24 | 2 | 2 |
2 | 7 | 2008.92 | 44 | 14.12 | 2985 | 1855 | 2.07 / 1009.10 | 2 | 2 |
3 | 13 | 1609.20 | 18 | 14.23 | 2496 | 639 | 2.71 / 1009.74 | 2 | 2 |
4 | 13 | 1195.60 | 18 | 14.33 | 1945 | 502 | 3.21 / 1010.24 | 2 | 2 |
5 | 13 | 624.44 | 18 | 14.59 | 1183 | 311 | 3.52 / 1010.55 | 2 | 2 |
6 | 13 | 89.60 | 18 | 14.88 | 449 | 120 | 3.64 / 1010.67 | 2 | 2 |
7 | 8 | -0.96 | 165 | 14.90 | 302 | 742 | 4.38 / 1011.41 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 30 | 14.87 | 496 | 221 | 0.22 / 1002.81 | 2 | 2 |
2 | 7 | 2004.88 | 44 | 14.14 | 2938 | 1828 | 2.05 / 1004.63 | 2 | 2 |
3 | 13 | 1740.56 | 18 | 14.21 | 2674 | 684 | 2.73 / 1005.32 | 2 | 2 |
4 | 13 | 1189.08 | 18 | 14.34 | 1953 | 504 | 3.24 / 1005.82 | 2 | 2 |
5 | 13 | 637.20 | 18 | 14.59 | 1231 | 323 | 3.56 / 1006.14 | 2 | 2 |
6 | 13 | 98.80 | 18 | 14.87 | 479 | 128 | 3.69 / 1006.27 | 2 | 2 |
7 | 8 | -1.00 | 165 | 14.90 | 307 | 755 | 4.44 / 1007.03 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 30 | 14.87 | 487 | 217 | 0.22 / 998.42 | 2 | 2 |
2 | 7 | 2007.36 | 44 | 14.14 | 2944 | 1832 | 2.05 / 1000.25 | 2 | 2 |
3 | 13 | 1607.12 | 18 | 14.25 | 2486 | 638 | 2.69 / 1000.89 | 2 | 2 |
4 | 13 | 1196.64 | 18 | 14.33 | 1973 | 509 | 3.20 / 1001.40 | 2 | 2 |
5 | 13 | 640.20 | 18 | 14.58 | 1236 | 324 | 3.52 / 1001.72 | 2 | 2 |
6 | 13 | 46.24 | 18 | 14.90 | 400 | 107 | 3.63 / 1001.83 | 2 | 2 |
7 | 8 | -0.92 | 165 | 14.89 | 308 | 757 | 4.38 / 1002.58 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 30 | 14.86 | 487 | 217 | 0.22 / 994.06 | 2 | 2 |
2 | 7 | 2009.08 | 44 | 14.13 | 2987 | 1857 | 2.07 / 995.92 | 2 | 2 |
3 | 13 | 1609.92 | 18 | 14.23 | 2485 | 637 | 2.71 / 996.55 | 2 | 2 |
4 | 13 | 1205.60 | 18 | 14.33 | 1969 | 508 | 3.22 / 997.06 | 2 | 2 |
5 | 13 | 518.60 | 18 | 14.65 | 1075 | 283 | 3.50 / 997.35 | 2 | 2 |
6 | 13 | 60.48 | 18 | 14.89 | 410 | 110 | 3.61 / 997.46 | 2 | 2 |
7 | 8 | -0.88 | 165 | 14.90 | 303 | 745 | 4.36 / 998.20 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 30 | 14.87 | 493 | 220 | 0.22 / 989.59 | 2 | 2 |
2 | 7 | 2005.96 | 44 | 14.13 | 2952 | 1835 | 2.06 / 991.42 | 2 | 2 |
3 | 13 | 1746.24 | 18 | 14.21 | 2663 | 681 | 2.74 / 992.10 | 2 | 2 |
4 | 13 | 1192.16 | 18 | 14.36 | 1908 | 493 | 3.23 / 992.60 | 2 | 2 |
5 | 13 | 763.92 | 18 | 14.52 | 1394 | 364 | 3.59 / 992.96 | 2 | 2 |
6 | 13 | 82.72 | 18 | 14.87 | 457 | 122 | 3.72 / 993.08 | 2 | 2 |
7 | 8 | -0.96 | 165 | 14.89 | 310 | 762 | 4.48 / 993.84 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 29 | 14.87 | 486 | 210 | 0.21 / 985.26 | 2 | 2 |
2 | 3 | 1021.16 | 1 | 14.97 | 1873 | 28 | 0.24 / 985.28 | 2 | 2 |
3 | 7 | 2004.08 | 44 | 14.14 | 2966 | 1845 | 2.08 / 987.13 | 2 | 2 |
4 | 13 | 1608.72 | 18 | 14.24 | 2496 | 640 | 2.72 / 987.77 | 2 | 2 |
5 | 13 | 1206.00 | 18 | 14.34 | 1983 | 512 | 3.23 / 988.28 | 2 | 2 |
6 | 13 | 641.40 | 18 | 14.58 | 1240 | 325 | 3.56 / 988.61 | 2 | 2 |
7 | 8 | -0.56 | 165 | 14.90 | 309 | 760 | 4.32 / 989.37 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 29 | 14.85 | 503 | 217 | 0.22 / 980.80 | 2 | 2 |
2 | 3 | 1020.44 | 1 | 14.97 | 1897 | 28 | 0.25 / 980.83 | 2 | 2 |
3 | 7 | 2004.00 | 44 | 14.14 | 2954 | 1838 | 2.08 / 982.67 | 2 | 2 |
4 | 13 | 1872.60 | 18 | 14.18 | 2846 | 726 | 2.81 / 983.40 | 2 | 2 |
5 | 13 | 1160.40 | 18 | 14.37 | 1897 | 491 | 3.30 / 983.89 | 2 | 2 |
6 | 13 | 611.60 | 18 | 14.60 | 1180 | 310 | 3.61 / 984.20 | 2 | 2 |
7 | 13 | 44.04 | 18 | 14.91 | 378 | 101 | 3.71 / 984.30 | 2 | 2 |
8 | 8 | -1.08 | 165 | 14.90 | 304 | 747 | 4.46 / 985.05 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 30 | 14.86 | 488 | 218 | 0.22 / 976.41 | 2 | 2 |
2 | 3 | 966.28 | -1 | 15.31 | 0 | 0 | 0.00 / 976.41 | 2 | 2 |
3 | 7 | 2007.80 | 44 | 14.14 | 2971 | 1848 | 2.07 / 978.26 | 2 | 2 |
4 | 13 | 1605.24 | 18 | 14.24 | 2498 | 640 | 2.71 / 978.90 | 2 | 2 |
5 | 13 | 1196.68 | 18 | 14.34 | 1970 | 508 | 3.21 / 979.41 | 2 | 2 |
6 | 13 | 628.56 | 18 | 14.59 | 1224 | 321 | 3.54 / 979.73 | 2 | 2 |
7 | 13 | 44.36 | 18 | 14.90 | 386 | 104 | 3.64 / 979.83 | 2 | 2 |
8 | 8 | -0.84 | 165 | 14.89 | 308 | 757 | 4.40 / 980.59 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 29 | 14.85 | 498 | 214 | 0.21 / 972.01 | 2 | 2 |
2 | 3 | 1020.68 | 1 | 14.98 | 1868 | 28 | 0.24 / 972.04 | 2 | 2 |
3 | 7 | 2005.12 | 44 | 14.14 | 2955 | 1838 | 2.08 / 973.88 | 2 | 2 |
4 | 13 | 1606.28 | 18 | 14.25 | 2497 | 640 | 2.72 / 974.52 | 2 | 2 |
5 | 13 | 1201.52 | 18 | 14.34 | 1968 | 508 | 3.23 / 975.03 | 2 | 2 |
6 | 13 | 641.56 | 18 | 14.59 | 1220 | 320 | 3.55 / 975.35 | 2 | 2 |
7 | 13 | 50.84 | 18 | 14.91 | 375 | 101 | 3.65 / 975.45 | 2 | 2 |
8 | 8 | -0.52 | 165 | 14.90 | 302 | 742 | 4.39 / 976.19 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 29 | 14.85 | 493 | 212 | 0.21 / 967.57 | 2 | 2 |
2 | 7 | 2004.96 | 44 | 14.14 | 2976 | 1852 | 2.06 / 969.42 | 2 | 2 |
3 | 13 | 1612.16 | 18 | 14.23 | 2524 | 646 | 2.71 / 970.07 | 2 | 2 |
4 | 13 | 1200.56 | 18 | 14.34 | 1967 | 508 | 3.22 / 970.57 | 2 | 2 |
5 | 13 | 642.48 | 18 | 14.58 | 1236 | 324 | 3.54 / 970.90 | 2 | 2 |
6 | 8 | 3.08 | 165 | 14.90 | 302 | 742 | 4.28 / 971.64 | 2 | 2 |
7 | 14 | 3.08 | 35 | 14.88 | 302 | 157 | 4.44 / 971.80 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 30 | 14.85 | 495 | 221 | 0.22 / 963.07 | 2 | 2 |
2 | 3 | 968.04 | -1 | 15.31 | 0 | 0 | 0.00 / 963.07 | 2 | 2 |
3 | 3 | 1020.24 | 1 | 15.00 | 1863 | 28 | 0.25 / 963.10 | 2 | 2 |
4 | 7 | 2008.44 | 44 | 14.14 | 2978 | 1853 | 2.10 / 964.95 | 2 | 2 |
5 | 13 | 1740.80 | 18 | 14.20 | 2661 | 680 | 2.78 / 965.63 | 2 | 2 |
6 | 13 | 1319.60 | 18 | 14.29 | 2115 | 544 | 3.33 / 966.17 | 2 | 2 |
7 | 13 | 605.64 | 18 | 14.61 | 1174 | 309 | 3.63 / 966.48 | 2 | 2 |
8 | 13 | 88.00 | 18 | 14.88 | 446 | 119 | 3.75 / 966.60 | 2 | 2 |
9 | 8 | -1.00 | 165 | 14.89 | 307 | 754 | 4.51 / 967.36 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 30 | 14.87 | 494 | 220 | 0.22 / 958.56 | 2 | 2 |
2 | 7 | 2002.80 | 44 | 14.13 | 3014 | 1874 | 2.09 / 960.43 | 2 | 2 |
3 | 13 | 1599.84 | 18 | 14.24 | 2504 | 642 | 2.74 / 961.07 | 2 | 2 |
4 | 13 | 1313.68 | 18 | 14.29 | 2105 | 541 | 3.28 / 961.62 | 2 | 2 |
5 | 13 | 737.84 | 18 | 14.53 | 1359 | 355 | 3.63 / 961.97 | 2 | 2 |
6 | 13 | 77.24 | 18 | 14.88 | 440 | 118 | 3.75 / 962.09 | 2 | 2 |
7 | 8 | -0.88 | 165 | 14.89 | 309 | 759 | 4.51 / 962.85 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 30 | 14.87 | 507 | 226 | 0.23 / 954.06 | 2 | 2 |
2 | 7 | 2008.84 | 44 | 14.14 | 2979 | 1853 | 2.08 / 955.91 | 2 | 2 |
3 | 13 | 1731.24 | 18 | 14.20 | 2691 | 688 | 2.77 / 956.60 | 2 | 2 |
4 | 13 | 1181.36 | 18 | 14.34 | 1968 | 508 | 3.28 / 957.11 | 2 | 2 |
5 | 13 | 634.36 | 18 | 14.59 | 1230 | 323 | 3.60 / 957.43 | 2 | 2 |
6 | 8 | -0.80 | 165 | 14.90 | 303 | 745 | 4.34 / 958.18 | 2 | 2 |
7 | 14 | -0.80 | 35 | 14.88 | 309 | 161 | 4.50 / 958.34 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 30 | 14.85 | 531 | 237 | 0.24 / 949.66 | 2 | 2 |
2 | 7 | 2007.92 | 44 | 14.15 | 2960 | 1843 | 2.08 / 951.50 | 2 | 2 |
3 | 13 | 1603.76 | 18 | 14.25 | 2510 | 644 | 2.72 / 952.15 | 2 | 2 |
4 | 13 | 1193.08 | 18 | 14.34 | 1954 | 504 | 3.23 / 952.65 | 2 | 2 |
5 | 13 | 499.04 | 18 | 14.66 | 1040 | 274 | 3.50 / 952.93 | 2 | 2 |
6 | 8 | -0.88 | 165 | 14.90 | 304 | 747 | 4.25 / 953.67 | 2 | 2 |
7 | 14 | -0.88 | 35 | 14.88 | 306 | 159 | 4.41 / 953.83 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 30 | 14.86 | 485 | 216 | 0.22 / 945.20 | 2 | 2 |
2 | 7 | 2007.16 | 44 | 14.15 | 2972 | 1850 | 2.07 / 947.05 | 2 | 2 |
3 | 13 | 1741.84 | 18 | 14.21 | 2674 | 684 | 2.75 / 947.73 | 2 | 2 |
4 | 13 | 1192.12 | 18 | 14.35 | 1949 | 503 | 3.25 / 948.24 | 2 | 2 |
5 | 13 | 621.88 | 18 | 14.59 | 1208 | 317 | 3.57 / 948.55 | 2 | 2 |
6 | 13 | 90.64 | 18 | 14.88 | 461 | 123 | 3.69 / 948.68 | 2 | 2 |
7 | 8 | -0.76 | 165 | 14.89 | 304 | 747 | 4.44 / 949.42 | 2 | 2 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 30 | 14.86 | 478 | 213 | 0.21 / 940.59 | 2 | 2 |
2 | 7 | 2008.36 | 44 | 14.15 | 2959 | 1842 | 2.06 / 942.43 | 2 | 2 |
3 | 13 | 1746.12 | 18 | 14.23 | 2621 | 671 | 2.73 / 943.10 | 2 | 2 |
4 | 13 | 1315.00 | 18 | 14.30 | 2131 | 549 | 3.28 / 943.65 | 2 | 2 |
5 | 13 | 609.04 | 18 | 14.61 | 1177 | 310 | 3.58 / 943.96 | 2 | 2 |
6 | 13 | 87.36 | 18 | 14.89 | 442 | 118 | 3.70 / 944.08 | 2 | 2 |
7 | 8 | -0.68 | 165 | 14.90 | 303 | 745 | 4.45 / 944.83 | 2 | 2 |
8 | 14 | -0.68 | 35 | 14.88 | 302 | 157 | 4.61 / 944.98 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 29 | 14.88 | 502 | 217 | 0.22 / 936.25 | 2 | 2 |
2 | 3 | 1037.72 | 1 | 14.93 | 1880 | 28 | 0.24 / 936.28 | 2 | 2 |
3 | 7 | 2006.32 | 44 | 14.15 | 2955 | 1840 | 2.08 / 938.12 | 2 | 2 |
4 | 13 | 1613.72 | 18 | 14.24 | 2490 | 638 | 2.72 / 938.76 | 2 | 2 |
5 | 13 | 1206.72 | 18 | 14.35 | 1930 | 499 | 3.22 / 939.26 | 2 | 2 |
6 | 13 | 525.72 | 18 | 14.65 | 1065 | 281 | 3.50 / 939.54 | 2 | 2 |
7 | 13 | 58.40 | 18 | 14.91 | 387 | 104 | 3.61 / 939.64 | 2 | 2 |
8 | 8 | -1.00 | 165 | 14.90 | 299 | 735 | 4.34 / 940.38 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 30 | 14.87 | 504 | 225 | 0.22 / 931.98 | 2 | 2 |
2 | 3 | 955.52 | -1 | 15.32 | 0 | 0 | 0.00 / 931.98 | 2 | 2 |
3 | 7 | 2004.68 | 44 | 14.14 | 2977 | 1852 | 2.08 / 933.84 | 2 | 2 |
4 | 13 | 1733.44 | 18 | 14.24 | 2635 | 675 | 2.75 / 934.51 | 2 | 2 |
5 | 13 | 1171.00 | 18 | 14.36 | 1939 | 501 | 3.25 / 935.01 | 2 | 2 |
6 | 13 | 489.60 | 18 | 14.66 | 1037 | 274 | 3.53 / 935.29 | 2 | 2 |
7 | 8 | -0.56 | 165 | 14.91 | 305 | 750 | 4.28 / 936.04 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 30 | 14.86 | 513 | 229 | 0.23 / 927.31 | 2 | 2 |
2 | 7 | 2006.76 | 44 | 14.16 | 2948 | 1837 | 2.07 / 929.14 | 2 | 2 |
3 | 13 | 1877.60 | 18 | 14.18 | 2821 | 720 | 2.79 / 929.86 | 2 | 2 |
4 | 13 | 1146.28 | 18 | 14.38 | 1906 | 493 | 3.28 / 930.36 | 2 | 2 |
5 | 13 | 727.16 | 18 | 14.54 | 1350 | 353 | 3.63 / 930.71 | 2 | 2 |
6 | 13 | 135.08 | 18 | 14.86 | 532 | 142 | 3.77 / 930.85 | 2 | 2 |
7 | 8 | -0.76 | 165 | 14.90 | 303 | 745 | 4.52 / 931.60 | 2 | 2 |
8 | 14 | -0.76 | 35 | 14.88 | 309 | 161 | 4.68 / 931.76 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 30 | 14.88 | 500 | 223 | 0.22 / 922.87 | 2 | 2 |
2 | 7 | 2009.12 | 44 | 14.15 | 2960 | 1843 | 2.07 / 924.71 | 2 | 2 |
3 | 13 | 1603.64 | 18 | 14.27 | 2456 | 631 | 2.70 / 925.34 | 2 | 2 |
4 | 13 | 1186.16 | 18 | 14.36 | 1947 | 503 | 3.20 / 925.85 | 2 | 2 |
5 | 13 | 757.56 | 18 | 14.53 | 1385 | 362 | 3.56 / 926.21 | 2 | 2 |
6 | 13 | 81.68 | 18 | 14.89 | 447 | 120 | 3.68 / 926.33 | 2 | 2 |
7 | 8 | -1.12 | 165 | 14.90 | 305 | 750 | 4.43 / 927.08 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 30 | 14.87 | 492 | 219 | 0.22 / 918.45 | 2 | 2 |
2 | 7 | 2003.88 | 44 | 14.15 | 2988 | 1860 | 2.08 / 920.31 | 2 | 2 |
3 | 13 | 1732.08 | 18 | 14.23 | 2648 | 678 | 2.76 / 920.99 | 2 | 2 |
4 | 13 | 1170.20 | 18 | 14.36 | 1938 | 501 | 3.26 / 921.49 | 2 | 2 |
5 | 13 | 613.08 | 18 | 14.61 | 1200 | 316 | 3.57 / 921.81 | 2 | 2 |
6 | 13 | 40.36 | 18 | 14.92 | 367 | 99 | 3.67 / 921.90 | 2 | 2 |
7 | 8 | -0.80 | 165 | 14.91 | 302 | 743 | 4.42 / 922.65 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 30 | 14.88 | 480 | 214 | 0.21 / 913.98 | 2 | 2 |
2 | 7 | 2007.68 | 44 | 14.14 | 2990 | 1860 | 2.07 / 915.84 | 2 | 2 |
3 | 13 | 1743.12 | 18 | 14.22 | 2669 | 683 | 2.76 / 916.53 | 2 | 2 |
4 | 13 | 1304.48 | 18 | 14.31 | 2098 | 540 | 3.30 / 917.07 | 2 | 2 |
5 | 13 | 594.64 | 18 | 14.62 | 1173 | 309 | 3.61 / 917.38 | 2 | 2 |
6 | 13 | 78.16 | 18 | 14.90 | 434 | 116 | 3.72 / 917.49 | 2 | 2 |
7 | 8 | -1.08 | 165 | 14.91 | 300 | 738 | 4.46 / 918.23 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 30 | 14.88 | 488 | 218 | 0.22 / 909.52 | 2 | 2 |
2 | 7 | 2006.08 | 44 | 14.15 | 2953 | 1839 | 2.06 / 911.36 | 2 | 2 |
3 | 13 | 1877.64 | 18 | 14.19 | 2861 | 731 | 2.79 / 912.09 | 2 | 2 |
4 | 13 | 1158.88 | 18 | 14.38 | 1894 | 490 | 3.28 / 912.58 | 2 | 2 |
5 | 13 | 748.80 | 18 | 14.55 | 1354 | 355 | 3.63 / 912.93 | 2 | 2 |
6 | 13 | 79.40 | 18 | 14.91 | 421 | 113 | 3.74 / 913.04 | 2 | 2 |
7 | 8 | -0.76 | 165 | 14.91 | 295 | 726 | 4.47 / 913.77 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 30 | 14.89 | 502 | 224 | 0.22 / 905.02 | 2 | 2 |
2 | 7 | 2005.52 | 44 | 14.16 | 2955 | 1841 | 2.07 / 906.86 | 2 | 2 |
3 | 13 | 1602.56 | 18 | 14.25 | 2500 | 641 | 2.71 / 907.50 | 2 | 2 |
4 | 13 | 1327.88 | 18 | 14.30 | 2118 | 545 | 3.25 / 908.05 | 2 | 2 |
5 | 13 | 736.08 | 18 | 14.54 | 1364 | 357 | 3.61 / 908.41 | 2 | 2 |
6 | 13 | 142.56 | 18 | 14.85 | 545 | 146 | 3.75 / 908.55 | 2 | 2 |
7 | 8 | -0.80 | 165 | 14.90 | 304 | 747 | 4.50 / 909.30 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 30 | 14.87 | 495 | 221 | 0.22 / 900.61 | 2 | 2 |
2 | 7 | 2004.16 | 44 | 14.16 | 2923 | 1821 | 2.04 / 902.43 | 2 | 2 |
3 | 13 | 1736.20 | 18 | 14.23 | 2658 | 681 | 2.72 / 903.11 | 2 | 2 |
4 | 13 | 1169.36 | 18 | 14.37 | 1907 | 493 | 3.22 / 903.61 | 2 | 2 |
5 | 13 | 618.84 | 18 | 14.61 | 1198 | 315 | 3.53 / 903.92 | 2 | 2 |
6 | 13 | 87.20 | 18 | 14.89 | 462 | 124 | 3.65 / 904.05 | 2 | 2 |
7 | 8 | -1.08 | 165 | 14.91 | 305 | 750 | 4.41 / 904.80 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 30 | 14.88 | 502 | 224 | 0.22 / 896.22 | 2 | 2 |
2 | 7 | 2004.08 | 44 | 14.16 | 2951 | 1839 | 2.06 / 898.05 | 2 | 2 |
3 | 13 | 1734.68 | 18 | 14.23 | 2671 | 684 | 2.75 / 898.74 | 2 | 2 |
4 | 13 | 1171.92 | 18 | 14.37 | 1916 | 496 | 3.24 / 899.23 | 2 | 2 |
5 | 13 | 601.00 | 18 | 14.61 | 1190 | 313 | 3.56 / 899.55 | 2 | 2 |
6 | 13 | 41.32 | 18 | 14.92 | 370 | 99 | 3.65 / 899.65 | 2 | 2 |
7 | 8 | -0.68 | 165 | 14.91 | 303 | 745 | 4.40 / 900.39 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 30 | 14.87 | 483 | 215 | 0.22 / 891.80 | 2 | 2 |
2 | 7 | 2003.48 | 44 | 14.15 | 2973 | 1851 | 2.07 / 893.65 | 2 | 2 |
3 | 13 | 1606.92 | 18 | 14.26 | 2488 | 639 | 2.71 / 894.29 | 2 | 2 |
4 | 13 | 1065.72 | 18 | 14.42 | 1793 | 465 | 3.17 / 894.76 | 2 | 2 |
5 | 13 | 781.84 | 18 | 14.52 | 1426 | 373 | 3.54 / 895.13 | 2 | 2 |
6 | 13 | 84.72 | 18 | 14.89 | 448 | 120 | 3.66 / 895.25 | 2 | 2 |
7 | 8 | -0.64 | 165 | 14.90 | 302 | 742 | 4.41 / 895.99 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 30 | 14.87 | 492 | 219 | 0.22 / 887.16 | 2 | 2 |
2 | 7 | 2007.44 | 44 | 14.15 | 2997 | 1866 | 2.09 / 889.03 | 2 | 2 |
3 | 13 | 1605.24 | 18 | 14.28 | 2445 | 628 | 2.71 / 889.66 | 2 | 2 |
4 | 13 | 1190.24 | 18 | 14.36 | 1952 | 505 | 3.22 / 890.16 | 2 | 2 |
5 | 13 | 905.72 | 18 | 14.46 | 1570 | 409 | 3.63 / 890.57 | 2 | 2 |
6 | 13 | 70.12 | 18 | 14.90 | 420 | 113 | 3.74 / 890.68 | 2 | 2 |
7 | 8 | -0.84 | 165 | 14.90 | 304 | 747 | 4.49 / 891.43 | 2 | 2 |
8 | 14 | -0.84 | 35 | 14.88 | 298 | 155 | 4.64 / 891.59 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 30 | 14.88 | 494 | 221 | 0.22 / 882.76 | 2 | 2 |
2 | 7 | 2004.84 | 44 | 14.15 | 2967 | 1847 | 2.07 / 884.61 | 2 | 2 |
3 | 13 | 1613.84 | 18 | 14.25 | 2469 | 633 | 2.70 / 885.24 | 2 | 2 |
4 | 13 | 1198.40 | 18 | 14.36 | 1949 | 504 | 3.20 / 885.74 | 2 | 2 |
5 | 13 | 644.24 | 18 | 14.60 | 1236 | 325 | 3.53 / 886.07 | 2 | 2 |
6 | 13 | 97.88 | 18 | 14.88 | 472 | 126 | 3.66 / 886.20 | 2 | 2 |
7 | 8 | -0.64 | 165 | 14.90 | 304 | 747 | 4.40 / 886.94 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 30 | 14.88 | 486 | 217 | 0.22 / 878.33 | 2 | 2 |
2 | 7 | 2003.96 | 44 | 14.16 | 2937 | 1830 | 2.05 / 880.16 | 2 | 2 |
3 | 13 | 1747.56 | 18 | 14.23 | 2692 | 690 | 2.74 / 880.85 | 2 | 2 |
4 | 13 | 1190.48 | 18 | 14.37 | 1958 | 506 | 3.24 / 881.35 | 2 | 2 |
5 | 13 | 628.40 | 18 | 14.61 | 1208 | 318 | 3.56 / 881.67 | 2 | 2 |
6 | 13 | 90.16 | 18 | 14.89 | 465 | 125 | 3.69 / 881.80 | 2 | 2 |
7 | 8 | -0.60 | 165 | 14.90 | 303 | 745 | 4.43 / 882.54 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 30 | 14.88 | 489 | 218 | 0.22 / 873.92 | 2 | 2 |
2 | 7 | 2007.76 | 44 | 14.15 | 2996 | 1865 | 2.08 / 875.79 | 2 | 2 |
3 | 13 | 1598.68 | 18 | 14.25 | 2522 | 647 | 2.73 / 876.43 | 2 | 2 |
4 | 13 | 1183.96 | 18 | 14.36 | 1941 | 502 | 3.23 / 876.94 | 2 | 2 |
5 | 13 | 622.72 | 18 | 14.60 | 1207 | 317 | 3.55 / 877.25 | 2 | 2 |
6 | 13 | 48.20 | 18 | 14.92 | 390 | 105 | 3.65 / 877.36 | 2 | 2 |
7 | 8 | -0.92 | 165 | 14.91 | 306 | 753 | 4.41 / 878.11 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 30 | 14.89 | 478 | 214 | 0.21 / 869.49 | 2 | 2 |
2 | 7 | 2006.20 | 44 | 14.16 | 2943 | 1834 | 2.05 / 871.32 | 2 | 2 |
3 | 13 | 1734.40 | 18 | 14.23 | 2649 | 679 | 2.73 / 872.00 | 2 | 2 |
4 | 13 | 1189.72 | 18 | 14.37 | 1957 | 506 | 3.23 / 872.50 | 2 | 2 |
5 | 13 | 632.80 | 18 | 14.60 | 1216 | 320 | 3.55 / 872.82 | 2 | 2 |
6 | 13 | 100.44 | 18 | 14.88 | 491 | 132 | 3.68 / 872.96 | 2 | 2 |
7 | 8 | -0.84 | 165 | 14.91 | 304 | 748 | 4.43 / 873.70 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 30 | 14.88 | 483 | 216 | 0.22 / 865.03 | 2 | 2 |
2 | 7 | 2004.44 | 44 | 14.16 | 2989 | 1862 | 2.08 / 866.89 | 2 | 2 |
3 | 13 | 1732.92 | 18 | 14.25 | 2629 | 674 | 2.75 / 867.57 | 2 | 2 |
4 | 13 | 1285.84 | 18 | 14.34 | 2098 | 542 | 3.29 / 868.11 | 2 | 2 |
5 | 13 | 581.84 | 18 | 14.64 | 1162 | 306 | 3.60 / 868.42 | 2 | 2 |
6 | 13 | 73.56 | 18 | 14.91 | 434 | 116 | 3.72 / 868.53 | 2 | 2 |
7 | 8 | -0.56 | 165 | 14.91 | 301 | 741 | 4.46 / 869.27 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 30 | 14.88 | 490 | 219 | 0.22 / 860.63 | 2 | 2 |
2 | 7 | 2004.68 | 44 | 14.16 | 2964 | 1847 | 2.07 / 862.48 | 2 | 2 |
3 | 13 | 1600.36 | 18 | 14.26 | 2480 | 637 | 2.70 / 863.11 | 2 | 2 |
4 | 13 | 1192.96 | 18 | 14.36 | 1962 | 507 | 3.21 / 863.62 | 2 | 2 |
5 | 13 | 633.00 | 18 | 14.61 | 1231 | 324 | 3.53 / 863.94 | 2 | 2 |
6 | 13 | 88.32 | 18 | 14.89 | 464 | 124 | 3.66 / 864.07 | 2 | 2 |
7 | 8 | -0.84 | 165 | 14.91 | 304 | 748 | 4.41 / 864.82 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 30 | 14.88 | 503 | 225 | 0.22 / 856.27 | 2 | 2 |
2 | 7 | 2007.16 | 44 | 14.17 | 2965 | 1849 | 2.07 / 858.12 | 2 | 2 |
3 | 13 | 1483.44 | 18 | 14.30 | 2320 | 597 | 2.67 / 858.72 | 2 | 2 |
4 | 13 | 1211.68 | 18 | 14.36 | 1970 | 509 | 3.18 / 859.23 | 2 | 2 |
5 | 13 | 644.40 | 18 | 14.60 | 1247 | 328 | 3.51 / 859.56 | 2 | 2 |
6 | 13 | 47.96 | 18 | 14.92 | 391 | 105 | 3.61 / 859.66 | 2 | 2 |
7 | 8 | -0.80 | 165 | 14.91 | 304 | 748 | 4.36 / 860.41 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 30 | 14.88 | 478 | 213 | 0.21 / 851.82 | 2 | 2 |
2 | 7 | 2010.48 | 44 | 14.15 | 2973 | 1851 | 2.06 / 853.67 | 2 | 2 |
3 | 13 | 1747.00 | 18 | 14.24 | 2687 | 689 | 2.75 / 854.36 | 2 | 2 |
4 | 13 | 1193.04 | 18 | 14.37 | 1985 | 513 | 3.27 / 854.87 | 2 | 2 |
5 | 13 | 636.00 | 18 | 14.61 | 1243 | 327 | 3.59 / 855.20 | 2 | 2 |
6 | 13 | 50.84 | 18 | 14.92 | 398 | 107 | 3.70 / 855.30 | 2 | 2 |
7 | 8 | -0.92 | 165 | 14.92 | 303 | 746 | 4.45 / 856.05 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 30 | 14.88 | 487 | 217 | 0.22 / 847.42 | 2 | 2 |
2 | 7 | 2002.64 | 44 | 14.17 | 2974 | 1854 | 2.07 / 849.28 | 2 | 2 |
3 | 13 | 1589.16 | 18 | 14.28 | 2469 | 635 | 2.71 / 849.91 | 2 | 2 |
4 | 13 | 1172.04 | 18 | 14.39 | 1935 | 501 | 3.21 / 850.41 | 2 | 2 |
5 | 13 | 611.40 | 18 | 14.62 | 1214 | 319 | 3.53 / 850.73 | 2 | 2 |
6 | 13 | 80.16 | 18 | 14.90 | 449 | 120 | 3.65 / 850.85 | 2 | 2 |
7 | 8 | -0.68 | 165 | 14.91 | 305 | 750 | 4.40 / 851.60 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 30 | 14.90 | 482 | 215 | 0.22 / 842.96 | 2 | 2 |
2 | 7 | 2005.84 | 44 | 14.16 | 2963 | 1846 | 2.06 / 844.81 | 2 | 2 |
3 | 13 | 1874.12 | 18 | 14.20 | 2846 | 727 | 2.79 / 845.54 | 2 | 2 |
4 | 13 | 1167.44 | 18 | 14.39 | 1945 | 504 | 3.29 / 846.04 | 2 | 2 |
5 | 13 | 606.08 | 18 | 14.63 | 1188 | 313 | 3.61 / 846.35 | 2 | 2 |
6 | 13 | 42.44 | 18 | 14.94 | 378 | 102 | 3.71 / 846.46 | 2 | 2 |
7 | 8 | -0.32 | 165 | 14.92 | 305 | 751 | 4.46 / 847.21 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 30 | 14.89 | 501 | 224 | 0.22 / 838.53 | 2 | 2 |
2 | 7 | 2003.96 | 44 | 14.17 | 2947 | 1837 | 2.06 / 840.36 | 2 | 2 |
3 | 13 | 1735.04 | 18 | 14.24 | 2650 | 679 | 2.74 / 841.04 | 2 | 2 |
4 | 13 | 1184.92 | 18 | 14.40 | 1904 | 494 | 3.23 / 841.54 | 2 | 2 |
5 | 13 | 765.44 | 18 | 14.56 | 1381 | 362 | 3.60 / 841.90 | 2 | 2 |
6 | 13 | 45.28 | 18 | 14.94 | 374 | 101 | 3.70 / 842.00 | 2 | 2 |
7 | 8 | -0.92 | 165 | 14.92 | 304 | 748 | 4.44 / 842.75 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 30 | 14.87 | 499 | 223 | 0.22 / 834.03 | 2 | 2 |
2 | 7 | 2003.68 | 45 | 14.17 | 2971 | 1894 | 2.12 / 835.92 | 2 | 2 |
3 | 13 | 1733.08 | 18 | 14.24 | 2675 | 686 | 2.80 / 836.61 | 2 | 2 |
4 | 13 | 1292.20 | 18 | 14.34 | 2095 | 541 | 3.34 / 837.15 | 2 | 2 |
5 | 13 | 583.08 | 18 | 14.64 | 1167 | 308 | 3.65 / 837.45 | 2 | 2 |
6 | 13 | 35.48 | 18 | 14.94 | 367 | 99 | 3.75 / 837.55 | 2 | 2 |
7 | 8 | -0.48 | 165 | 14.92 | 305 | 751 | 4.50 / 838.30 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 30 | 14.88 | 503 | 225 | 0.22 / 829.59 | 2 | 2 |
2 | 7 | 2004.00 | 44 | 14.18 | 2943 | 1836 | 2.06 / 831.43 | 2 | 2 |
3 | 13 | 1732.48 | 18 | 14.25 | 2661 | 683 | 2.74 / 832.11 | 2 | 2 |
4 | 13 | 1178.44 | 18 | 14.39 | 1954 | 506 | 3.25 / 832.62 | 2 | 2 |
5 | 13 | 617.84 | 18 | 14.63 | 1209 | 318 | 3.57 / 832.93 | 2 | 2 |
6 | 13 | 91.40 | 18 | 14.90 | 465 | 125 | 3.69 / 833.06 | 2 | 2 |
7 | 8 | -0.76 | 165 | 14.92 | 302 | 743 | 4.44 / 833.80 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 30 | 14.87 | 495 | 221 | 0.22 / 825.14 | 2 | 2 |
2 | 7 | 2005.36 | 44 | 14.18 | 2956 | 1844 | 2.07 / 826.99 | 2 | 2 |
3 | 13 | 1740.00 | 18 | 14.24 | 2670 | 684 | 2.75 / 827.67 | 2 | 2 |
4 | 13 | 1184.72 | 18 | 14.39 | 1949 | 505 | 3.25 / 828.17 | 2 | 2 |
5 | 13 | 622.16 | 18 | 14.63 | 1217 | 320 | 3.57 / 828.50 | 2 | 2 |
6 | 13 | 92.84 | 18 | 14.90 | 469 | 126 | 3.70 / 828.62 | 2 | 2 |
7 | 8 | -0.72 | 165 | 14.92 | 303 | 746 | 4.45 / 829.37 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 30 | 14.88 | 499 | 223 | 0.22 / 820.73 | 2 | 2 |
2 | 7 | 2004.92 | 44 | 14.16 | 3004 | 1872 | 2.09 / 822.61 | 2 | 2 |
3 | 13 | 1600.76 | 18 | 14.29 | 2487 | 640 | 2.73 / 823.25 | 2 | 2 |
4 | 13 | 1191.84 | 18 | 14.38 | 1986 | 514 | 3.25 / 823.76 | 2 | 2 |
5 | 13 | 617.28 | 18 | 14.63 | 1202 | 317 | 3.56 / 824.08 | 2 | 2 |
6 | 13 | 20.72 | 18 | 14.95 | 336 | 90 | 3.66 / 824.17 | 2 | 2 |
7 | 8 | -0.48 | 165 | 14.92 | 306 | 753 | 4.41 / 824.92 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 30 | 14.88 | 499 | 223 | 0.22 / 816.53 | 2 | 2 |
2 | 7 | 2004.36 | 44 | 14.19 | 2950 | 1842 | 2.06 / 818.37 | 2 | 2 |
3 | 13 | 1610.96 | 18 | 14.29 | 2477 | 637 | 2.70 / 819.00 | 2 | 2 |
4 | 13 | 1073.72 | 18 | 14.45 | 1797 | 467 | 3.17 / 819.47 | 2 | 2 |
5 | 13 | 537.48 | 18 | 14.68 | 1092 | 289 | 3.46 / 819.76 | 2 | 2 |
6 | 8 | -0.44 | 165 | 14.93 | 305 | 751 | 4.21 / 820.51 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 30 | 14.87 | 497 | 222 | 0.22 / 812.03 | 2 | 2 |
2 | 7 | 2002.60 | 44 | 14.18 | 2944 | 1837 | 2.06 / 813.87 | 2 | 2 |
3 | 13 | 1726.56 | 18 | 14.26 | 2656 | 682 | 2.74 / 814.55 | 2 | 2 |
4 | 13 | 1295.32 | 18 | 14.35 | 2120 | 548 | 3.29 / 815.10 | 2 | 2 |
5 | 13 | 720.00 | 18 | 14.58 | 1355 | 356 | 3.64 / 815.46 | 2 | 2 |
6 | 13 | 32.88 | 18 | 14.95 | 364 | 98 | 3.74 / 815.55 | 2 | 2 |
7 | 8 | -0.64 | 165 | 14.93 | 304 | 749 | 4.49 / 816.30 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 30 | 14.86 | 496 | 221 | 0.22 / 807.55 | 2 | 2 |
2 | 7 | 2005.04 | 44 | 14.17 | 2991 | 1865 | 2.09 / 809.42 | 2 | 2 |
3 | 13 | 1731.36 | 18 | 14.26 | 2631 | 675 | 2.76 / 810.09 | 2 | 2 |
4 | 13 | 1169.60 | 18 | 14.41 | 1912 | 496 | 3.26 / 810.59 | 2 | 2 |
5 | 13 | 741.00 | 18 | 14.58 | 1353 | 355 | 3.61 / 810.94 | 2 | 2 |
6 | 13 | 70.84 | 18 | 14.92 | 425 | 114 | 3.73 / 811.06 | 2 | 2 |
7 | 8 | -0.40 | 165 | 14.92 | 307 | 756 | 4.48 / 811.81 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 30 | 14.87 | 509 | 227 | 0.23 / 802.99 | 2 | 2 |
2 | 7 | 2004.72 | 44 | 14.17 | 2994 | 1867 | 2.09 / 804.85 | 2 | 2 |
3 | 13 | 1740.56 | 18 | 14.25 | 2665 | 684 | 2.78 / 805.54 | 2 | 2 |
4 | 13 | 1306.88 | 18 | 14.36 | 2104 | 544 | 3.32 / 806.08 | 2 | 2 |
5 | 13 | 724.80 | 18 | 14.59 | 1352 | 355 | 3.68 / 806.44 | 2 | 2 |
6 | 13 | 143.60 | 18 | 14.88 | 535 | 143 | 3.82 / 806.58 | 2 | 2 |
7 | 8 | -0.56 | 165 | 14.92 | 305 | 751 | 4.57 / 807.33 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 30 | 14.87 | 511 | 228 | 0.23 / 798.55 | 2 | 2 |
2 | 7 | 2005.20 | 44 | 14.19 | 2944 | 1838 | 2.07 / 800.39 | 2 | 2 |
3 | 13 | 1729.44 | 18 | 14.27 | 2645 | 679 | 2.75 / 801.07 | 2 | 2 |
4 | 13 | 1165.56 | 18 | 14.41 | 1938 | 503 | 3.25 / 801.57 | 2 | 2 |
5 | 13 | 611.16 | 18 | 14.65 | 1197 | 316 | 3.56 / 801.89 | 2 | 2 |
6 | 13 | 41.60 | 18 | 14.94 | 386 | 104 | 3.67 / 801.99 | 2 | 2 |
7 | 8 | -0.48 | 165 | 14.92 | 312 | 768 | 4.44 / 802.76 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 30 | 14.87 | 514 | 229 | 0.23 / 794.10 | 2 | 2 |
2 | 7 | 2001.52 | 44 | 14.20 | 2955 | 1846 | 2.08 / 795.95 | 2 | 2 |
3 | 13 | 1732.56 | 18 | 14.27 | 2637 | 677 | 2.75 / 796.62 | 2 | 2 |
4 | 13 | 1165.48 | 18 | 14.41 | 1928 | 500 | 3.25 / 797.12 | 2 | 2 |
5 | 13 | 606.80 | 18 | 14.65 | 1190 | 314 | 3.57 / 797.44 | 2 | 2 |
6 | 13 | 79.48 | 18 | 14.92 | 448 | 120 | 3.69 / 797.56 | 2 | 2 |
7 | 8 | -0.56 | 165 | 14.92 | 311 | 766 | 4.45 / 798.32 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 30 | 14.87 | 500 | 223 | 0.22 / 789.65 | 2 | 2 |
2 | 7 | 2005.04 | 44 | 14.19 | 2962 | 1849 | 2.07 / 791.50 | 2 | 2 |
3 | 13 | 1600.44 | 18 | 14.29 | 2507 | 645 | 2.72 / 792.14 | 2 | 2 |
4 | 13 | 1192.56 | 18 | 14.40 | 1971 | 511 | 3.23 / 792.65 | 2 | 2 |
5 | 13 | 508.44 | 18 | 14.70 | 1055 | 279 | 3.51 / 792.93 | 2 | 2 |
6 | 13 | 31.64 | 18 | 14.95 | 363 | 98 | 3.60 / 793.03 | 2 | 2 |
7 | 13 | 9.52 | 18 | 14.96 | 326 | 88 | 3.69 / 793.12 | 2 | 2 |
8 | 8 | -0.68 | 165 | 14.92 | 307 | 756 | 4.45 / 793.87 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 30 | 14.88 | 517 | 231 | 0.23 / 785.18 | 2 | 2 |
2 | 7 | 2006.92 | 44 | 14.19 | 2944 | 1838 | 2.07 / 787.01 | 2 | 2 |
3 | 13 | 1751.24 | 18 | 14.25 | 2716 | 697 | 2.77 / 787.71 | 2 | 2 |
4 | 13 | 1185.08 | 18 | 14.39 | 1959 | 507 | 3.27 / 788.22 | 2 | 2 |
5 | 13 | 633.00 | 18 | 14.64 | 1229 | 324 | 3.60 / 788.54 | 2 | 2 |
6 | 13 | 90.00 | 18 | 14.91 | 473 | 127 | 3.72 / 788.67 | 2 | 2 |
7 | 8 | -0.84 | 165 | 14.92 | 306 | 753 | 4.48 / 789.42 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 30 | 14.88 | 492 | 220 | 0.22 / 780.70 | 2 | 2 |
2 | 7 | 2006.08 | 44 | 14.18 | 2973 | 1855 | 2.07 / 782.55 | 2 | 2 |
3 | 13 | 1740.00 | 18 | 14.26 | 2661 | 683 | 2.76 / 783.24 | 2 | 2 |
4 | 13 | 1172.72 | 18 | 14.42 | 1913 | 497 | 3.25 / 783.73 | 2 | 2 |
5 | 13 | 749.68 | 18 | 14.59 | 1370 | 360 | 3.61 / 784.09 | 2 | 2 |
6 | 13 | 42.32 | 18 | 14.95 | 373 | 100 | 3.71 / 784.19 | 2 | 2 |
7 | 8 | -0.36 | 165 | 14.93 | 305 | 751 | 4.47 / 784.95 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 29 | 14.89 | 526 | 227 | 0.23 / 776.28 | 2 | 2 |
2 | 3 | 1032.96 | 1 | 15.00 | 1863 | 28 | 0.26 / 776.31 | 2 | 2 |
3 | 7 | 2002.12 | 44 | 14.19 | 2970 | 1854 | 2.11 / 778.16 | 2 | 2 |
4 | 13 | 1719.08 | 18 | 14.27 | 2644 | 679 | 2.79 / 778.84 | 2 | 2 |
5 | 13 | 1043.40 | 18 | 14.48 | 1763 | 460 | 3.25 / 779.30 | 2 | 2 |
6 | 13 | 639.24 | 18 | 14.64 | 1241 | 327 | 3.58 / 779.63 | 2 | 2 |
7 | 13 | 45.00 | 18 | 14.95 | 381 | 103 | 3.68 / 779.73 | 2 | 2 |
8 | 8 | -0.36 | 165 | 14.93 | 304 | 749 | 4.43 / 780.48 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 30 | 14.88 | 501 | 224 | 0.22 / 771.94 | 2 | 2 |
2 | 3 | 953.92 | -1 | 15.35 | 0 | 0 | 0.00 / 771.94 | 2 | 2 |
3 | 7 | 2005.40 | 44 | 14.19 | 2955 | 1845 | 2.07 / 773.79 | 2 | 2 |
4 | 13 | 1736.92 | 18 | 14.27 | 2645 | 679 | 2.75 / 774.47 | 2 | 2 |
5 | 13 | 1176.80 | 18 | 14.41 | 1957 | 508 | 3.26 / 774.97 | 2 | 2 |
6 | 13 | 619.08 | 18 | 14.65 | 1209 | 319 | 3.57 / 775.29 | 2 | 2 |
7 | 8 | -0.60 | 165 | 14.94 | 309 | 762 | 4.34 / 776.05 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 30 | 14.88 | 510 | 228 | 0.23 / 767.37 | 2 | 2 |
2 | 7 | 2007.24 | 44 | 14.18 | 2995 | 1869 | 2.10 / 769.24 | 2 | 2 |
3 | 13 | 1609.28 | 18 | 14.30 | 2497 | 643 | 2.74 / 769.88 | 2 | 2 |
4 | 13 | 1193.08 | 18 | 14.41 | 1940 | 503 | 3.24 / 770.38 | 2 | 2 |
5 | 13 | 480.40 | 18 | 14.72 | 1023 | 271 | 3.51 / 770.65 | 2 | 2 |
6 | 13 | 91.76 | 18 | 14.92 | 471 | 126 | 3.64 / 770.78 | 2 | 2 |
7 | 8 | -0.40 | 165 | 14.93 | 313 | 771 | 4.41 / 771.55 | 2 | 2 |
8 | 14 | -0.40 | 35 | 14.90 | 317 | 165 | 4.58 / 771.72 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 30 | 14.88 | 518 | 231 | 0.23 / 762.90 | 2 | 2 |
2 | 7 | 2006.76 | 44 | 14.19 | 2978 | 1859 | 2.09 / 764.76 | 2 | 2 |
3 | 13 | 1737.36 | 18 | 14.27 | 2649 | 680 | 2.77 / 765.44 | 2 | 2 |
4 | 13 | 1186.48 | 18 | 14.42 | 1928 | 500 | 3.27 / 765.94 | 2 | 2 |
5 | 13 | 621.80 | 18 | 14.67 | 1188 | 314 | 3.59 / 766.26 | 2 | 2 |
6 | 13 | 89.52 | 18 | 14.93 | 465 | 125 | 3.71 / 766.38 | 2 | 2 |
7 | 8 | -0.64 | 165 | 14.93 | 309 | 761 | 4.47 / 767.14 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 30 | 14.89 | 524 | 234 | 0.23 / 758.56 | 2 | 2 |
2 | 7 | 2003.28 | 44 | 14.18 | 3005 | 1875 | 2.11 / 760.44 | 2 | 2 |
3 | 13 | 1601.76 | 18 | 14.31 | 2486 | 640 | 2.75 / 761.08 | 2 | 2 |
4 | 13 | 1188.84 | 18 | 14.41 | 1961 | 509 | 3.26 / 761.59 | 2 | 2 |
5 | 13 | 625.52 | 18 | 14.65 | 1222 | 322 | 3.58 / 761.91 | 2 | 2 |
6 | 8 | -0.40 | 165 | 14.94 | 308 | 759 | 4.34 / 762.67 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 30 | 14.90 | 508 | 227 | 0.23 / 754.20 | 2 | 2 |
2 | 7 | 2003.32 | 44 | 14.20 | 2954 | 1846 | 2.07 / 756.05 | 2 | 2 |
3 | 13 | 1605.76 | 18 | 14.30 | 2489 | 641 | 2.71 / 756.69 | 2 | 2 |
4 | 13 | 1201.92 | 18 | 14.40 | 1974 | 512 | 3.23 / 757.20 | 2 | 2 |
5 | 13 | 508.56 | 18 | 14.71 | 1051 | 278 | 3.50 / 757.48 | 2 | 2 |
6 | 13 | 23.20 | 18 | 14.97 | 346 | 93 | 3.60 / 757.57 | 2 | 2 |
7 | 8 | -0.44 | 165 | 14.94 | 308 | 759 | 4.36 / 758.33 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 30 | 14.90 | 501 | 224 | 0.22 / 749.73 | 2 | 2 |
2 | 7 | 2009.00 | 44 | 14.19 | 2994 | 1869 | 2.09 / 751.60 | 2 | 2 |
3 | 13 | 1741.12 | 18 | 14.28 | 2668 | 686 | 2.78 / 752.28 | 2 | 2 |
4 | 13 | 1186.16 | 18 | 14.43 | 1946 | 505 | 3.28 / 752.79 | 2 | 2 |
5 | 13 | 606.40 | 18 | 14.67 | 1194 | 315 | 3.60 / 753.10 | 2 | 2 |
6 | 13 | 87.28 | 18 | 14.93 | 462 | 124 | 3.72 / 753.23 | 2 | 2 |
7 | 8 | -0.64 | 165 | 14.94 | 303 | 747 | 4.47 / 753.97 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 30 | 14.89 | 509 | 227 | 0.23 / 745.21 | 2 | 2 |
2 | 7 | 2006.12 | 44 | 14.21 | 2952 | 1846 | 2.07 / 747.05 | 2 | 2 |
3 | 13 | 1740.12 | 18 | 14.28 | 2633 | 677 | 2.75 / 747.73 | 2 | 2 |
4 | 13 | 1316.68 | 18 | 14.37 | 2141 | 554 | 3.30 / 748.28 | 2 | 2 |
5 | 13 | 727.80 | 18 | 14.61 | 1354 | 356 | 3.66 / 748.64 | 2 | 2 |
6 | 13 | 63.48 | 18 | 14.95 | 425 | 114 | 3.77 / 748.75 | 2 | 2 |
7 | 8 | -0.40 | 165 | 14.94 | 304 | 749 | 4.52 / 749.50 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 30 | 14.91 | 486 | 217 | 0.22 / 740.74 | 2 | 2 |
2 | 7 | 2007.68 | 44 | 14.19 | 2989 | 1866 | 2.08 / 742.61 | 2 | 2 |
3 | 13 | 1616.20 | 18 | 14.31 | 2492 | 642 | 2.73 / 743.25 | 2 | 2 |
4 | 13 | 1203.28 | 18 | 14.40 | 1985 | 515 | 3.24 / 743.76 | 2 | 2 |
5 | 13 | 632.64 | 18 | 14.65 | 1235 | 326 | 3.57 / 744.09 | 2 | 2 |
6 | 13 | 92.52 | 18 | 14.92 | 477 | 128 | 3.69 / 744.22 | 2 | 2 |
7 | 8 | -0.64 | 165 | 14.94 | 309 | 762 | 4.46 / 744.98 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 30 | 14.90 | 492 | 220 | 0.22 / 736.18 | 2 | 2 |
2 | 7 | 2003.84 | 45 | 14.19 | 2968 | 1895 | 2.12 / 738.07 | 2 | 2 |
3 | 13 | 1872.84 | 18 | 14.24 | 2849 | 730 | 2.85 / 738.80 | 2 | 2 |
4 | 13 | 1281.80 | 18 | 14.39 | 2083 | 540 | 3.38 / 739.34 | 2 | 2 |
5 | 13 | 596.96 | 18 | 14.68 | 1171 | 309 | 3.69 / 739.65 | 2 | 2 |
6 | 13 | 75.84 | 18 | 14.94 | 444 | 119 | 3.81 / 739.77 | 2 | 2 |
7 | 8 | -0.76 | 165 | 14.94 | 306 | 754 | 4.57 / 740.52 | 2 | 2 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 30 | 14.90 | 508 | 227 | 0.23 / 731.72 | 2 | 2 |
2 | 7 | 2003.24 | 44 | 14.21 | 2940 | 1838 | 2.07 / 733.56 | 2 | 2 |
3 | 13 | 1735.80 | 18 | 14.27 | 2694 | 692 | 2.76 / 734.25 | 2 | 2 |
4 | 13 | 1176.88 | 18 | 14.43 | 1924 | 500 | 3.26 / 734.75 | 2 | 2 |
5 | 13 | 634.12 | 18 | 14.65 | 1230 | 324 | 3.58 / 735.08 | 2 | 2 |
6 | 13 | 94.12 | 18 | 14.93 | 470 | 126 | 3.71 / 735.20 | 2 | 2 |
7 | 8 | -0.40 | 165 | 14.94 | 306 | 754 | 4.46 / 735.96 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 29 | 14.90 | 491 | 212 | 0.21 / 727.36 | 2 | 2 |
2 | 7 | 2005.04 | 44 | 14.19 | 2995 | 1870 | 2.08 / 729.23 | 2 | 2 |
3 | 13 | 1732.44 | 18 | 14.27 | 2677 | 688 | 2.77 / 729.92 | 2 | 2 |
4 | 13 | 1162.96 | 18 | 14.43 | 1937 | 503 | 3.27 / 730.42 | 2 | 2 |
5 | 13 | 605.04 | 18 | 14.67 | 1190 | 314 | 3.59 / 730.74 | 2 | 2 |
6 | 8 | -0.28 | 165 | 14.95 | 308 | 760 | 4.35 / 731.49 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 29 | 14.91 | 498 | 215 | 0.22 / 722.86 | 2 | 2 |
2 | 7 | 2006.20 | 44 | 14.21 | 2951 | 1845 | 2.06 / 724.70 | 2 | 2 |
3 | 13 | 1744.92 | 18 | 14.27 | 2705 | 695 | 2.76 / 725.40 | 2 | 2 |
4 | 13 | 1175.00 | 18 | 14.43 | 1949 | 506 | 3.26 / 725.90 | 2 | 2 |
5 | 13 | 746.04 | 18 | 14.60 | 1371 | 360 | 3.62 / 726.26 | 2 | 2 |
6 | 13 | 73.80 | 18 | 14.94 | 439 | 118 | 3.74 / 726.38 | 2 | 2 |
7 | 8 | -0.64 | 165 | 14.94 | 311 | 767 | 4.51 / 727.15 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 29 | 14.91 | 503 | 217 | 0.22 / 718.45 | 2 | 2 |
2 | 7 | 2003.72 | 44 | 14.20 | 2951 | 1844 | 2.06 / 720.29 | 2 | 2 |
3 | 13 | 1729.32 | 18 | 14.28 | 2650 | 681 | 2.74 / 720.97 | 2 | 2 |
4 | 13 | 1052.12 | 18 | 14.48 | 1775 | 463 | 3.21 / 721.43 | 2 | 2 |
5 | 13 | 636.28 | 18 | 14.66 | 1245 | 329 | 3.53 / 721.76 | 2 | 2 |
6 | 13 | 55.44 | 18 | 14.96 | 408 | 110 | 3.64 / 721.87 | 2 | 2 |
7 | 8 | -0.48 | 165 | 14.95 | 312 | 770 | 4.41 / 722.64 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 29 | 14.92 | 504 | 218 | 0.22 / 713.99 | 2 | 2 |
2 | 7 | 2010.12 | 44 | 14.20 | 2953 | 1845 | 2.06 / 715.83 | 2 | 2 |
3 | 13 | 1746.28 | 18 | 14.28 | 2674 | 687 | 2.75 / 716.52 | 2 | 2 |
4 | 13 | 1180.68 | 18 | 14.43 | 1950 | 506 | 3.26 / 717.03 | 2 | 2 |
5 | 13 | 616.20 | 18 | 14.67 | 1213 | 320 | 3.58 / 717.35 | 2 | 2 |
6 | 13 | 84.32 | 18 | 14.93 | 465 | 125 | 3.70 / 717.47 | 2 | 2 |
7 | 8 | -0.52 | 165 | 14.95 | 307 | 757 | 4.46 / 718.23 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 29 | 14.92 | 479 | 207 | 0.21 / 709.45 | 2 | 2 |
2 | 7 | 2005.16 | 44 | 14.20 | 2979 | 1861 | 2.07 / 711.31 | 2 | 2 |
3 | 13 | 1731.20 | 18 | 14.29 | 2647 | 681 | 2.75 / 711.99 | 2 | 2 |
4 | 13 | 1302.76 | 18 | 14.38 | 2125 | 550 | 3.30 / 712.54 | 2 | 2 |
5 | 13 | 711.76 | 18 | 14.63 | 1333 | 351 | 3.65 / 712.89 | 2 | 2 |
6 | 13 | 60.92 | 18 | 14.95 | 417 | 112 | 3.76 / 713.01 | 2 | 2 |
7 | 8 | -0.36 | 165 | 14.95 | 309 | 762 | 4.52 / 713.77 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 29 | 14.92 | 492 | 213 | 0.21 / 705.04 | 2 | 2 |
2 | 7 | 2004.32 | 44 | 14.19 | 2976 | 1858 | 2.07 / 706.90 | 2 | 2 |
3 | 13 | 1728.36 | 18 | 14.29 | 2662 | 685 | 2.76 / 707.58 | 2 | 2 |
4 | 13 | 1166.88 | 18 | 14.44 | 1929 | 501 | 3.26 / 708.08 | 2 | 2 |
5 | 13 | 604.92 | 18 | 14.68 | 1175 | 310 | 3.57 / 708.39 | 2 | 2 |
6 | 13 | 44.24 | 18 | 14.97 | 396 | 107 | 3.67 / 708.50 | 2 | 2 |
7 | 8 | -0.60 | 165 | 14.96 | 302 | 745 | 4.42 / 709.24 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 29 | 14.93 | 492 | 213 | 0.21 / 700.62 | 2 | 2 |
2 | 7 | 2006.68 | 44 | 14.20 | 2965 | 1853 | 2.07 / 702.47 | 2 | 2 |
3 | 13 | 1611.44 | 18 | 14.32 | 2487 | 641 | 2.71 / 703.11 | 2 | 2 |
4 | 13 | 1188.40 | 18 | 14.43 | 1963 | 510 | 3.22 / 703.62 | 2 | 2 |
5 | 13 | 629.36 | 18 | 14.66 | 1225 | 323 | 3.54 / 703.95 | 2 | 2 |
6 | 13 | 89.28 | 18 | 14.94 | 461 | 124 | 3.66 / 704.07 | 2 | 2 |
7 | 8 | -0.36 | 165 | 14.95 | 306 | 755 | 4.42 / 704.82 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 29 | 14.92 | 489 | 212 | 0.21 / 696.18 | 2 | 2 |
2 | 7 | 2008.20 | 44 | 14.20 | 2963 | 1851 | 2.06 / 698.04 | 2 | 2 |
3 | 13 | 1610.28 | 18 | 14.32 | 2482 | 640 | 2.70 / 698.67 | 2 | 2 |
4 | 13 | 1327.28 | 18 | 14.38 | 2107 | 545 | 3.25 / 699.22 | 2 | 2 |
5 | 13 | 597.64 | 18 | 14.69 | 1164 | 308 | 3.56 / 699.53 | 2 | 2 |
6 | 13 | 82.08 | 18 | 14.94 | 457 | 123 | 3.68 / 699.65 | 2 | 2 |
7 | 8 | -0.60 | 165 | 14.95 | 306 | 755 | 4.43 / 700.41 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 29 | 14.91 | 491 | 212 | 0.21 / 691.65 | 2 | 2 |
2 | 7 | 2007.12 | 44 | 14.20 | 2984 | 1864 | 2.08 / 693.51 | 2 | 2 |
3 | 13 | 1602.44 | 18 | 14.31 | 2506 | 645 | 2.72 / 694.16 | 2 | 2 |
4 | 13 | 1187.28 | 18 | 14.43 | 1956 | 508 | 3.23 / 694.67 | 2 | 2 |
5 | 13 | 890.20 | 18 | 14.53 | 1564 | 409 | 3.64 / 695.07 | 2 | 2 |
6 | 13 | 119.04 | 18 | 14.92 | 508 | 136 | 3.78 / 695.21 | 2 | 2 |
7 | 8 | -0.56 | 165 | 14.94 | 309 | 762 | 4.54 / 695.97 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 29 | 14.92 | 494 | 214 | 0.21 / 687.23 | 2 | 2 |
2 | 7 | 2002.92 | 44 | 14.20 | 2955 | 1846 | 2.06 / 689.08 | 2 | 2 |
3 | 13 | 1601.64 | 18 | 14.32 | 2492 | 642 | 2.70 / 689.72 | 2 | 2 |
4 | 13 | 1185.80 | 18 | 14.43 | 1969 | 511 | 3.21 / 690.23 | 2 | 2 |
5 | 13 | 606.20 | 18 | 14.67 | 1201 | 317 | 3.53 / 690.55 | 2 | 2 |
6 | 13 | 73.68 | 18 | 14.94 | 446 | 120 | 3.65 / 690.67 | 2 | 2 |
7 | 8 | -0.32 | 165 | 14.95 | 311 | 767 | 4.42 / 691.43 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 29 | 14.92 | 484 | 209 | 0.21 / 682.79 | 2 | 2 |
2 | 7 | 2003.60 | 44 | 14.20 | 2989 | 1868 | 2.08 / 684.65 | 2 | 2 |
3 | 13 | 1723.64 | 18 | 14.29 | 2645 | 680 | 2.76 / 685.33 | 2 | 2 |
4 | 13 | 1159.52 | 18 | 14.45 | 1912 | 497 | 3.25 / 685.83 | 2 | 2 |
5 | 13 | 595.88 | 18 | 14.68 | 1177 | 311 | 3.57 / 686.14 | 2 | 2 |
6 | 13 | 74.12 | 18 | 14.95 | 440 | 118 | 3.68 / 686.26 | 2 | 2 |
7 | 8 | -0.40 | 165 | 14.95 | 307 | 757 | 4.44 / 687.02 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 29 | 14.92 | 511 | 221 | 0.22 / 678.37 | 2 | 2 |
2 | 7 | 2006.24 | 44 | 14.21 | 2958 | 1849 | 2.07 / 680.22 | 2 | 2 |
3 | 13 | 1602.68 | 18 | 14.32 | 2517 | 649 | 2.72 / 680.87 | 2 | 2 |
4 | 13 | 1188.24 | 18 | 14.42 | 1970 | 511 | 3.23 / 681.38 | 2 | 2 |
5 | 13 | 622.52 | 18 | 14.67 | 1206 | 318 | 3.55 / 681.70 | 2 | 2 |
6 | 13 | 84.00 | 18 | 14.94 | 454 | 122 | 3.67 / 681.82 | 2 | 2 |
7 | 8 | -0.52 | 165 | 14.95 | 306 | 755 | 4.43 / 682.58 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 29 | 14.92 | 491 | 212 | 0.21 / 674.02 | 2 | 2 |
2 | 7 | 2003.76 | 44 | 14.21 | 2943 | 1840 | 2.05 / 675.86 | 2 | 2 |
3 | 13 | 1604.72 | 18 | 14.32 | 2511 | 647 | 2.70 / 676.51 | 2 | 2 |
4 | 13 | 1183.04 | 18 | 14.43 | 1952 | 507 | 3.21 / 677.01 | 2 | 2 |
5 | 13 | 482.36 | 18 | 14.74 | 1021 | 271 | 3.48 / 677.29 | 2 | 2 |
6 | 13 | 49.04 | 18 | 14.97 | 395 | 106 | 3.58 / 677.39 | 2 | 2 |
7 | 8 | -0.40 | 165 | 14.96 | 307 | 758 | 4.34 / 678.15 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 29 | 14.91 | 515 | 223 | 0.22 / 669.52 | 2 | 2 |
2 | 7 | 2008.48 | 44 | 14.20 | 2991 | 1869 | 2.09 / 671.38 | 2 | 2 |
3 | 13 | 1740.56 | 18 | 14.29 | 2664 | 685 | 2.78 / 672.07 | 2 | 2 |
4 | 13 | 1179.20 | 18 | 14.44 | 1956 | 508 | 3.29 / 672.58 | 2 | 2 |
5 | 13 | 749.32 | 18 | 14.61 | 1381 | 363 | 3.65 / 672.94 | 2 | 2 |
6 | 13 | 71.28 | 18 | 14.96 | 433 | 117 | 3.76 / 673.06 | 2 | 2 |
7 | 8 | -0.36 | 165 | 14.96 | 304 | 750 | 4.52 / 673.81 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 29 | 14.92 | 509 | 220 | 0.22 / 665.08 | 2 | 2 |
2 | 7 | 2004.00 | 44 | 14.20 | 2975 | 1859 | 2.08 / 666.94 | 2 | 2 |
3 | 13 | 1599.48 | 18 | 14.33 | 2513 | 648 | 2.73 / 667.59 | 2 | 2 |
4 | 13 | 1181.12 | 18 | 14.43 | 1957 | 508 | 3.24 / 668.09 | 2 | 2 |
5 | 13 | 617.88 | 18 | 14.67 | 1209 | 319 | 3.55 / 668.41 | 2 | 2 |
6 | 13 | 80.76 | 18 | 14.95 | 453 | 122 | 3.68 / 668.54 | 2 | 2 |
7 | 8 | -0.60 | 165 | 14.95 | 307 | 757 | 4.43 / 669.29 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 29 | 14.90 | 501 | 216 | 0.22 / 660.67 | 2 | 2 |
2 | 7 | 2002.92 | 44 | 14.21 | 2949 | 1844 | 2.06 / 662.52 | 2 | 2 |
3 | 13 | 1730.24 | 18 | 14.32 | 2614 | 674 | 2.73 / 663.19 | 2 | 2 |
4 | 13 | 1157.16 | 18 | 14.45 | 1910 | 497 | 3.23 / 663.69 | 2 | 2 |
5 | 13 | 581.64 | 18 | 14.70 | 1156 | 306 | 3.54 / 663.99 | 2 | 2 |
6 | 13 | 33.20 | 18 | 14.98 | 366 | 99 | 3.64 / 664.09 | 2 | 2 |
7 | 8 | -0.44 | 165 | 14.96 | 310 | 765 | 4.40 / 664.86 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 29 | 14.91 | 504 | 218 | 0.22 / 656.25 | 2 | 2 |
2 | 7 | 2003.56 | 44 | 14.21 | 2972 | 1858 | 2.08 / 658.11 | 2 | 2 |
3 | 13 | 1734.24 | 18 | 14.29 | 2679 | 689 | 2.77 / 658.80 | 2 | 2 |
4 | 13 | 1153.00 | 18 | 14.45 | 1910 | 497 | 3.26 / 659.30 | 2 | 2 |
5 | 13 | 593.12 | 18 | 14.70 | 1165 | 308 | 3.57 / 659.61 | 2 | 2 |
6 | 13 | 35.44 | 18 | 14.99 | 364 | 98 | 3.67 / 659.70 | 2 | 2 |
7 | 8 | -0.36 | 165 | 14.96 | 305 | 753 | 4.42 / 660.46 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 29 | 14.91 | 507 | 219 | 0.22 / 651.79 | 2 | 2 |
2 | 7 | 2004.68 | 44 | 14.22 | 2932 | 1834 | 2.05 / 653.63 | 2 | 2 |
3 | 13 | 1731.44 | 18 | 14.29 | 2673 | 688 | 2.74 / 654.31 | 2 | 2 |
4 | 13 | 1298.88 | 18 | 14.39 | 2103 | 545 | 3.29 / 654.86 | 2 | 2 |
5 | 13 | 591.76 | 18 | 14.69 | 1167 | 309 | 3.59 / 655.17 | 2 | 2 |
6 | 13 | 43.96 | 18 | 14.98 | 388 | 105 | 3.70 / 655.27 | 2 | 2 |
7 | 8 | -0.40 | 165 | 14.96 | 310 | 765 | 4.46 / 656.04 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 29 | 14.91 | 502 | 217 | 0.22 / 647.28 | 2 | 2 |
2 | 7 | 2007.44 | 45 | 14.21 | 2973 | 1901 | 2.12 / 649.19 | 2 | 2 |
3 | 13 | 1612.32 | 18 | 14.34 | 2496 | 644 | 2.76 / 649.83 | 2 | 2 |
4 | 13 | 1201.44 | 18 | 14.43 | 1960 | 509 | 3.27 / 650.34 | 2 | 2 |
5 | 13 | 769.40 | 18 | 14.60 | 1414 | 372 | 3.64 / 650.71 | 2 | 2 |
6 | 13 | 42.24 | 18 | 14.98 | 385 | 104 | 3.75 / 650.81 | 2 | 2 |
7 | 8 | -0.52 | 165 | 14.96 | 307 | 758 | 4.50 / 651.57 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 29 | 14.90 | 497 | 215 | 0.21 / 642.84 | 2 | 2 |
2 | 7 | 2008.16 | 44 | 14.21 | 2958 | 1849 | 2.06 / 644.69 | 2 | 2 |
3 | 13 | 1732.48 | 18 | 14.29 | 2696 | 693 | 2.76 / 645.38 | 2 | 2 |
4 | 13 | 1051.52 | 18 | 14.50 | 1782 | 465 | 3.22 / 645.85 | 2 | 2 |
5 | 13 | 634.40 | 18 | 14.67 | 1232 | 325 | 3.55 / 646.17 | 2 | 2 |
6 | 13 | 85.20 | 18 | 14.95 | 460 | 124 | 3.67 / 646.30 | 2 | 2 |
7 | 8 | -0.48 | 165 | 14.95 | 313 | 772 | 4.44 / 647.07 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 29 | 14.91 | 490 | 212 | 0.21 / 638.40 | 2 | 2 |
2 | 7 | 2008.00 | 44 | 14.21 | 2979 | 1863 | 2.07 / 640.26 | 2 | 2 |
3 | 13 | 1733.12 | 18 | 14.28 | 2675 | 688 | 2.76 / 640.95 | 2 | 2 |
4 | 13 | 1158.52 | 18 | 14.46 | 1890 | 492 | 3.25 / 641.44 | 2 | 2 |
5 | 13 | 600.24 | 18 | 14.69 | 1183 | 313 | 3.57 / 641.75 | 2 | 2 |
6 | 13 | 36.16 | 18 | 14.99 | 383 | 103 | 3.67 / 641.86 | 2 | 2 |
7 | 8 | -0.40 | 165 | 14.96 | 310 | 765 | 4.44 / 642.62 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 29 | 14.91 | 507 | 219 | 0.22 / 633.91 | 2 | 2 |
2 | 7 | 2002.96 | 44 | 14.22 | 2950 | 1846 | 2.06 / 635.76 | 2 | 2 |
3 | 13 | 1739.68 | 18 | 14.30 | 2675 | 689 | 2.75 / 636.45 | 2 | 2 |
4 | 13 | 1308.40 | 18 | 14.40 | 2135 | 553 | 3.31 / 637.00 | 2 | 2 |
5 | 13 | 585.16 | 18 | 14.70 | 1165 | 308 | 3.62 / 637.31 | 2 | 2 |
6 | 13 | 75.84 | 18 | 14.96 | 441 | 119 | 3.73 / 637.43 | 2 | 2 |
7 | 8 | -0.52 | 165 | 14.96 | 308 | 760 | 4.49 / 638.19 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 29 | 14.91 | 512 | 221 | 0.22 / 629.45 | 2 | 2 |
2 | 7 | 2002.76 | 44 | 14.21 | 2967 | 1855 | 2.08 / 631.30 | 2 | 2 |
3 | 13 | 1738.44 | 18 | 14.30 | 2681 | 690 | 2.77 / 631.99 | 2 | 2 |
4 | 13 | 1170.40 | 18 | 14.45 | 1938 | 504 | 3.27 / 632.49 | 2 | 2 |
5 | 13 | 607.12 | 18 | 14.69 | 1193 | 315 | 3.59 / 632.81 | 2 | 2 |
6 | 13 | 79.44 | 18 | 14.96 | 449 | 121 | 3.71 / 632.93 | 2 | 2 |
7 | 8 | -0.28 | 165 | 14.96 | 309 | 763 | 4.47 / 633.69 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 29 | 14.89 | 520 | 225 | 0.22 / 625.03 | 2 | 2 |
2 | 7 | 2007.04 | 44 | 14.20 | 2991 | 1869 | 2.09 / 626.90 | 2 | 2 |
3 | 13 | 1605.96 | 18 | 14.34 | 2493 | 643 | 2.74 / 627.54 | 2 | 2 |
4 | 13 | 1185.60 | 18 | 14.44 | 1968 | 512 | 3.25 / 628.05 | 2 | 2 |
5 | 13 | 478.44 | 18 | 14.76 | 1028 | 273 | 3.52 / 628.32 | 2 | 2 |
6 | 13 | 95.80 | 18 | 14.95 | 485 | 131 | 3.65 / 628.45 | 2 | 2 |
7 | 8 | -0.60 | 165 | 14.96 | 312 | 770 | 4.42 / 629.22 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 29 | 14.91 | 515 | 223 | 0.22 / 620.61 | 2 | 2 |
2 | 7 | 2004.00 | 44 | 14.22 | 2960 | 1852 | 2.07 / 622.47 | 2 | 2 |
3 | 13 | 1601.24 | 18 | 14.34 | 2488 | 642 | 2.72 / 623.11 | 2 | 2 |
4 | 13 | 1186.76 | 18 | 14.44 | 1957 | 509 | 3.23 / 623.62 | 2 | 2 |
5 | 13 | 496.08 | 18 | 14.74 | 1046 | 278 | 3.50 / 623.89 | 2 | 2 |
6 | 13 | 98.20 | 18 | 14.95 | 486 | 131 | 3.63 / 624.02 | 2 | 2 |
7 | 8 | -0.24 | 165 | 14.96 | 315 | 778 | 4.41 / 624.80 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 29 | 14.92 | 515 | 223 | 0.22 / 616.29 | 2 | 2 |
2 | 7 | 2005.72 | 44 | 14.20 | 2999 | 1874 | 2.10 / 618.17 | 2 | 2 |
3 | 13 | 1590.20 | 18 | 14.34 | 2462 | 635 | 2.73 / 618.80 | 2 | 2 |
4 | 13 | 1053.04 | 18 | 14.51 | 1759 | 459 | 3.19 / 619.26 | 2 | 2 |
5 | 13 | 501.84 | 18 | 14.75 | 1030 | 273 | 3.46 / 619.54 | 2 | 2 |
6 | 13 | 24.48 | 18 | 15.00 | 332 | 90 | 3.55 / 619.62 | 2 | 2 |
7 | 8 | -0.16 | 165 | 14.97 | 310 | 766 | 4.32 / 620.39 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 29 | 14.91 | 502 | 217 | 0.22 / 611.70 | 2 | 2 |
2 | 7 | 2007.44 | 44 | 14.21 | 2996 | 1873 | 2.09 / 613.57 | 2 | 2 |
3 | 13 | 1597.28 | 18 | 14.35 | 2475 | 639 | 2.73 / 614.21 | 2 | 2 |
4 | 13 | 1190.68 | 18 | 14.43 | 1977 | 514 | 3.24 / 614.73 | 2 | 2 |
5 | 13 | 752.52 | 18 | 14.61 | 1400 | 368 | 3.61 / 615.10 | 2 | 2 |
6 | 13 | 73.92 | 18 | 14.96 | 439 | 118 | 3.73 / 615.21 | 2 | 2 |
7 | 13 | 15.92 | 18 | 14.99 | 340 | 92 | 3.82 / 615.31 | 2 | 2 |
8 | 8 | -0.20 | 165 | 14.96 | 310 | 765 | 4.59 / 616.07 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 29 | 14.91 | 516 | 223 | 0.22 / 607.24 | 2 | 2 |
2 | 7 | 2003.36 | 44 | 14.22 | 2954 | 1848 | 2.07 / 609.09 | 2 | 2 |
3 | 13 | 1598.28 | 18 | 14.35 | 2474 | 639 | 2.71 / 609.73 | 2 | 2 |
4 | 13 | 1185.80 | 18 | 14.46 | 1940 | 505 | 3.22 / 610.24 | 2 | 2 |
5 | 13 | 752.36 | 18 | 14.62 | 1397 | 368 | 3.58 / 610.60 | 2 | 2 |
6 | 13 | 64.28 | 18 | 14.97 | 421 | 113 | 3.70 / 610.72 | 2 | 2 |
7 | 8 | -0.20 | 165 | 14.96 | 311 | 768 | 4.46 / 611.48 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 29 | 14.91 | 494 | 214 | 0.21 / 602.79 | 2 | 2 |
2 | 7 | 2006.08 | 44 | 14.23 | 2942 | 1842 | 2.06 / 604.63 | 2 | 2 |
3 | 13 | 1744.16 | 18 | 14.31 | 2671 | 688 | 2.74 / 605.32 | 2 | 2 |
4 | 13 | 1175.80 | 18 | 14.46 | 1922 | 500 | 3.24 / 605.82 | 2 | 2 |
5 | 13 | 607.56 | 18 | 14.70 | 1184 | 313 | 3.56 / 606.13 | 2 | 2 |
6 | 13 | 78.64 | 18 | 14.97 | 454 | 122 | 3.68 / 606.25 | 2 | 2 |
7 | 8 | -0.44 | 165 | 14.97 | 310 | 766 | 4.45 / 607.02 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 29 | 14.92 | 495 | 214 | 0.21 / 598.29 | 2 | 2 |
2 | 7 | 2005.64 | 44 | 14.21 | 2989 | 1869 | 2.08 / 600.16 | 2 | 2 |
3 | 13 | 1599.80 | 18 | 14.34 | 2478 | 640 | 2.72 / 600.80 | 2 | 2 |
4 | 13 | 1319.16 | 18 | 14.40 | 2128 | 552 | 3.27 / 601.35 | 2 | 2 |
5 | 13 | 723.44 | 18 | 14.64 | 1347 | 355 | 3.63 / 601.70 | 2 | 2 |
6 | 13 | 61.96 | 18 | 14.98 | 411 | 111 | 3.74 / 601.81 | 2 | 2 |
7 | 8 | -0.08 | 165 | 14.97 | 308 | 761 | 4.50 / 602.57 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 29 | 14.92 | 490 | 212 | 0.21 / 593.69 | 2 | 2 |
2 | 7 | 2010.60 | 44 | 14.21 | 3014 | 1884 | 2.10 / 595.57 | 2 | 2 |
3 | 13 | 1737.96 | 18 | 14.31 | 2698 | 695 | 2.79 / 596.27 | 2 | 2 |
4 | 13 | 1299.56 | 18 | 14.41 | 2110 | 547 | 3.34 / 596.82 | 2 | 2 |
5 | 13 | 712.96 | 18 | 14.64 | 1349 | 355 | 3.69 / 597.17 | 2 | 2 |
6 | 13 | 131.56 | 18 | 14.93 | 528 | 142 | 3.84 / 597.31 | 2 | 2 |
7 | 8 | -0.60 | 165 | 14.97 | 308 | 761 | 4.60 / 598.07 | 2 | 2 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 29 | 14.93 | 493 | 213 | 0.21 / 589.16 | 2 | 2 |
2 | 7 | 2009.92 | 44 | 14.22 | 2974 | 1861 | 2.07 / 591.02 | 2 | 2 |
3 | 13 | 1612.04 | 18 | 14.34 | 2499 | 645 | 2.72 / 591.67 | 2 | 2 |
4 | 13 | 1188.16 | 18 | 14.45 | 1954 | 508 | 3.23 / 592.18 | 2 | 2 |
5 | 13 | 610.80 | 18 | 14.69 | 1201 | 318 | 3.55 / 592.49 | 2 | 2 |
6 | 13 | 84.24 | 18 | 14.96 | 460 | 124 | 3.67 / 592.62 | 2 | 2 |
7 | 13 | 17.88 | 18 | 14.99 | 348 | 94 | 3.76 / 592.71 | 2 | 2 |
8 | 8 | -0.28 | 165 | 14.96 | 310 | 765 | 4.53 / 593.48 | 2 | 2 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 29 | 14.93 | 503 | 218 | 0.22 / 584.68 | 2 | 2 |
2 | 7 | 2003.64 | 44 | 14.22 | 2965 | 1855 | 2.07 / 586.53 | 2 | 2 |
3 | 13 | 1607.92 | 18 | 14.35 | 2486 | 642 | 2.72 / 587.18 | 2 | 2 |
4 | 13 | 1192.80 | 18 | 14.45 | 1970 | 512 | 3.23 / 587.69 | 2 | 2 |
5 | 13 | 756.60 | 18 | 14.62 | 1390 | 366 | 3.59 / 588.05 | 2 | 2 |
6 | 13 | 75.88 | 18 | 14.96 | 451 | 121 | 3.71 / 588.18 | 2 | 2 |
7 | 8 | -0.60 | 165 | 14.97 | 313 | 773 | 4.49 / 588.95 | 2 | 2 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 28 | 14.94 | 507 | 212 | 0.21 / 580.35 | 2 | 2 |
2 | 7 | 2002.48 | 44 | 14.22 | 2961 | 1853 | 2.06 / 582.20 | 2 | 2 |
3 | 13 | 1590.88 | 18 | 14.35 | 2487 | 642 | 2.71 / 582.84 | 2 | 2 |
4 | 13 | 1046.36 | 18 | 14.50 | 1786 | 466 | 3.17 / 583.31 | 2 | 2 |
5 | 13 | 508.52 | 18 | 14.75 | 1065 | 283 | 3.46 / 583.59 | 2 | 2 |
6 | 13 | 52.08 | 18 | 14.98 | 407 | 110 | 3.57 / 583.70 | 2 | 2 |
7 | 8 | -0.52 | 165 | 14.97 | 307 | 758 | 4.32 / 584.46 | 2 | 2 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 29 | 14.94 | 505 | 219 | 0.22 / 575.95 | 2 | 2 |
2 | 7 | 2003.64 | 44 | 14.22 | 2973 | 1860 | 2.08 / 577.81 | 2 | 2 |
3 | 13 | 1732.48 | 18 | 14.31 | 2659 | 685 | 2.76 / 578.50 | 2 | 2 |
4 | 13 | 1156.08 | 18 | 14.47 | 1923 | 501 | 3.26 / 579.00 | 2 | 2 |
5 | 13 | 461.44 | 18 | 14.78 | 993 | 264 | 3.53 / 579.26 | 2 | 2 |
6 | 13 | 48.08 | 18 | 14.99 | 394 | 106 | 3.64 / 579.37 | 2 | 2 |
7 | 8 | -0.44 | 165 | 14.98 | 310 | 766 | 4.40 / 580.14 | 2 | 2 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 29 | 14.94 | 504 | 218 | 0.22 / 571.52 | 2 | 2 |
2 | 7 | 2006.96 | 44 | 14.23 | 2957 | 1851 | 2.07 / 573.37 | 2 | 2 |
3 | 13 | 1590.52 | 18 | 14.36 | 2469 | 638 | 2.71 / 574.01 | 2 | 2 |
4 | 13 | 1165.04 | 18 | 14.47 | 1914 | 499 | 3.21 / 574.51 | 2 | 2 |
5 | 13 | 725.04 | 18 | 14.64 | 1351 | 356 | 3.56 / 574.86 | 2 | 2 |
6 | 13 | 61.08 | 18 | 14.98 | 419 | 113 | 3.68 / 574.98 | 2 | 2 |
7 | 8 | -0.12 | 165 | 14.97 | 307 | 758 | 4.43 / 575.74 | 2 | 2 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 28 | 14.94 | 492 | 206 | 0.21 / 567.01 | 2 | 2 |
2 | 7 | 2010.40 | 44 | 14.22 | 2979 | 1864 | 2.07 / 568.87 | 2 | 2 |
3 | 13 | 1733.76 | 18 | 14.31 | 2666 | 687 | 2.76 / 569.56 | 2 | 2 |
4 | 13 | 1183.40 | 18 | 14.47 | 1945 | 507 | 3.26 / 570.06 | 2 | 2 |
5 | 13 | 755.48 | 18 | 14.63 | 1392 | 367 | 3.63 / 570.43 | 2 | 2 |
6 | 13 | 42.16 | 18 | 14.99 | 392 | 106 | 3.74 / 570.54 | 2 | 2 |
7 | 8 | -0.28 | 165 | 14.98 | 310 | 766 | 4.50 / 571.30 | 2 | 2 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 28 | 14.94 | 488 | 204 | 0.20 / 562.60 | 2 | 2 |
2 | 7 | 2002.88 | 44 | 14.22 | 2969 | 1858 | 2.06 / 564.46 | 2 | 2 |
3 | 13 | 1737.96 | 18 | 14.32 | 2666 | 687 | 2.75 / 565.14 | 2 | 2 |
4 | 13 | 1171.64 | 18 | 14.47 | 1959 | 510 | 3.26 / 565.65 | 2 | 2 |
5 | 13 | 498.64 | 18 | 14.76 | 1053 | 280 | 3.54 / 565.93 | 2 | 2 |
6 | 13 | 48.52 | 18 | 15.00 | 402 | 109 | 3.65 / 566.04 | 2 | 2 |
7 | 8 | -0.28 | 165 | 14.98 | 307 | 759 | 4.41 / 566.80 | 2 | 2 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 29 | 14.95 | 486 | 211 | 0.21 / 558.22 | 2 | 2 |
2 | 7 | 2004.40 | 44 | 14.22 | 2988 | 1870 | 2.08 / 560.09 | 2 | 2 |
3 | 13 | 1592.08 | 18 | 14.36 | 2489 | 643 | 2.72 / 560.74 | 2 | 2 |
4 | 13 | 1178.88 | 18 | 14.46 | 1930 | 502 | 3.23 / 561.24 | 2 | 2 |
5 | 13 | 469.00 | 18 | 14.78 | 1006 | 268 | 3.49 / 561.51 | 2 | 2 |
6 | 13 | 88.64 | 18 | 14.97 | 469 | 126 | 3.62 / 561.63 | 2 | 2 |
7 | 8 | -0.32 | 165 | 14.98 | 308 | 761 | 4.38 / 562.39 | 2 | 2 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 29 | 14.95 | 499 | 216 | 0.22 / 553.78 | 2 | 2 |
2 | 7 | 2003.92 | 44 | 14.23 | 2967 | 1858 | 2.07 / 555.64 | 2 | 2 |
3 | 13 | 1584.16 | 18 | 14.36 | 2471 | 639 | 2.71 / 556.28 | 2 | 2 |
4 | 13 | 1303.52 | 18 | 14.43 | 2107 | 547 | 3.26 / 556.83 | 2 | 2 |
5 | 13 | 576.88 | 18 | 14.72 | 1161 | 308 | 3.57 / 557.13 | 2 | 2 |
6 | 13 | 63.32 | 18 | 14.99 | 423 | 114 | 3.68 / 557.25 | 2 | 2 |
7 | 8 | -0.48 | 165 | 14.98 | 309 | 764 | 4.45 / 558.01 | 2 | 2 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 29 | 14.95 | 503 | 218 | 0.22 / 549.37 | 2 | 2 |
2 | 7 | 2007.76 | 44 | 14.24 | 2956 | 1852 | 2.07 / 551.22 | 2 | 2 |
3 | 13 | 1597.44 | 18 | 14.36 | 2463 | 637 | 2.71 / 551.86 | 2 | 2 |
4 | 13 | 1200.36 | 18 | 14.46 | 1975 | 514 | 3.22 / 552.37 | 2 | 2 |
5 | 13 | 645.32 | 18 | 14.69 | 1241 | 328 | 3.55 / 552.70 | 2 | 2 |
6 | 13 | 53.24 | 18 | 14.99 | 403 | 109 | 3.66 / 552.81 | 2 | 2 |
7 | 8 | -0.28 | 165 | 14.99 | 307 | 759 | 4.42 / 553.57 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 28 | 14.95 | 494 | 207 | 0.21 / 544.94 | 2 | 2 |
2 | 7 | 2002.72 | 44 | 14.22 | 2984 | 1867 | 2.07 / 546.81 | 2 | 2 |
3 | 13 | 1608.20 | 18 | 14.35 | 2521 | 651 | 2.72 / 547.46 | 2 | 2 |
4 | 13 | 1190.12 | 18 | 14.46 | 1959 | 510 | 3.23 / 547.97 | 2 | 2 |
5 | 13 | 611.44 | 18 | 14.71 | 1194 | 316 | 3.55 / 548.29 | 2 | 2 |
6 | 13 | 41.80 | 18 | 15.00 | 388 | 105 | 3.66 / 548.39 | 2 | 2 |
7 | 8 | -0.44 | 165 | 14.99 | 306 | 757 | 4.41 / 549.15 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 29 | 14.94 | 482 | 209 | 0.21 / 540.59 | 2 | 2 |
2 | 7 | 2004.52 | 44 | 14.23 | 2985 | 1869 | 2.08 / 542.46 | 2 | 2 |
3 | 13 | 1597.28 | 18 | 14.37 | 2490 | 644 | 2.72 / 543.10 | 2 | 2 |
4 | 13 | 1055.32 | 18 | 14.51 | 1799 | 470 | 3.19 / 543.57 | 2 | 2 |
5 | 13 | 515.04 | 18 | 14.76 | 1081 | 287 | 3.48 / 543.86 | 2 | 2 |
6 | 13 | 47.32 | 18 | 14.99 | 397 | 107 | 3.59 / 543.97 | 2 | 2 |
7 | 8 | 0.08 | 165 | 14.98 | 311 | 769 | 4.35 / 544.74 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 29 | 14.96 | 485 | 210 | 0.21 / 536.04 | 2 | 2 |
2 | 7 | 2007.72 | 44 | 14.23 | 2976 | 1863 | 2.07 / 537.90 | 2 | 2 |
3 | 13 | 1737.12 | 18 | 14.32 | 2665 | 687 | 2.76 / 538.59 | 2 | 2 |
4 | 13 | 1167.28 | 18 | 14.47 | 1924 | 501 | 3.26 / 539.09 | 2 | 2 |
5 | 13 | 598.96 | 18 | 14.72 | 1178 | 312 | 3.57 / 539.40 | 2 | 2 |
6 | 13 | 69.92 | 18 | 14.99 | 431 | 116 | 3.69 / 539.52 | 2 | 2 |
7 | 13 | 15.48 | 18 | 15.01 | 340 | 92 | 3.78 / 539.61 | 2 | 2 |
8 | 8 | -0.24 | 165 | 14.97 | 312 | 771 | 4.55 / 540.38 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 29 | 14.95 | 493 | 214 | 0.21 / 531.62 | 2 | 2 |
2 | 7 | 2002.76 | 44 | 14.24 | 2929 | 1835 | 2.05 / 533.45 | 2 | 2 |
3 | 13 | 1726.48 | 18 | 14.33 | 2649 | 683 | 2.73 / 534.14 | 2 | 2 |
4 | 13 | 1160.32 | 18 | 14.48 | 1928 | 503 | 3.23 / 534.64 | 2 | 2 |
5 | 13 | 600.52 | 18 | 14.72 | 1182 | 313 | 3.55 / 534.95 | 2 | 2 |
6 | 13 | 72.68 | 18 | 14.98 | 436 | 118 | 3.67 / 535.07 | 2 | 2 |
7 | 8 | -0.20 | 165 | 14.99 | 307 | 759 | 4.42 / 535.83 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 29 | 14.94 | 497 | 215 | 0.22 / 527.20 | 2 | 2 |
2 | 7 | 2006.44 | 44 | 14.24 | 2951 | 1849 | 2.06 / 529.05 | 2 | 2 |
3 | 13 | 1728.72 | 18 | 14.33 | 2630 | 678 | 2.74 / 529.73 | 2 | 2 |
4 | 13 | 1154.48 | 18 | 14.49 | 1910 | 498 | 3.24 / 530.22 | 2 | 2 |
5 | 13 | 588.96 | 18 | 14.73 | 1170 | 310 | 3.55 / 530.53 | 2 | 2 |
6 | 13 | 63.48 | 18 | 14.99 | 424 | 114 | 3.67 / 530.65 | 2 | 2 |
7 | 8 | -0.44 | 165 | 14.99 | 306 | 757 | 4.42 / 531.40 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 29 | 14.94 | 492 | 213 | 0.21 / 522.76 | 2 | 2 |
2 | 7 | 2002.68 | 44 | 14.23 | 2988 | 1871 | 2.08 / 524.63 | 2 | 2 |
3 | 13 | 1732.24 | 18 | 14.32 | 2668 | 688 | 2.77 / 525.32 | 2 | 2 |
4 | 13 | 1161.28 | 18 | 14.48 | 1905 | 497 | 3.27 / 525.81 | 2 | 2 |
5 | 13 | 585.04 | 18 | 14.72 | 1166 | 309 | 3.58 / 526.12 | 2 | 2 |
6 | 13 | 32.24 | 18 | 15.01 | 367 | 99 | 3.68 / 526.22 | 2 | 2 |
7 | 8 | -0.44 | 165 | 14.99 | 308 | 762 | 4.44 / 526.98 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 29 | 14.93 | 516 | 223 | 0.22 / 518.37 | 2 | 2 |
2 | 7 | 2009.24 | 45 | 14.24 | 2947 | 1888 | 2.11 / 520.25 | 2 | 2 |
3 | 13 | 1615.20 | 18 | 14.35 | 2540 | 656 | 2.77 / 520.91 | 2 | 2 |
4 | 13 | 1083.76 | 18 | 14.52 | 1826 | 477 | 3.25 / 521.39 | 2 | 2 |
5 | 13 | 519.08 | 18 | 14.76 | 1077 | 286 | 3.53 / 521.67 | 2 | 2 |
6 | 13 | 50.96 | 18 | 14.99 | 403 | 109 | 3.64 / 521.78 | 2 | 2 |
7 | 8 | -0.16 | 165 | 14.99 | 308 | 762 | 4.40 / 522.54 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 29 | 14.93 | 498 | 216 | 0.22 / 513.96 | 2 | 2 |
2 | 7 | 2002.88 | 45 | 14.24 | 2981 | 1910 | 2.13 / 515.87 | 2 | 2 |
3 | 13 | 1601.36 | 18 | 14.36 | 2511 | 649 | 2.77 / 516.52 | 2 | 2 |
4 | 13 | 1060.64 | 18 | 14.53 | 1781 | 466 | 3.24 / 516.99 | 2 | 2 |
5 | 13 | 498.00 | 18 | 14.78 | 1050 | 279 | 3.52 / 517.27 | 2 | 2 |
6 | 13 | 45.60 | 18 | 15.00 | 389 | 105 | 3.63 / 517.37 | 2 | 2 |
7 | 8 | -0.16 | 165 | 14.99 | 312 | 772 | 4.40 / 518.14 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 29 | 14.93 | 498 | 216 | 0.22 / 509.55 | 2 | 2 |
2 | 7 | 2003.64 | 44 | 14.24 | 2967 | 1859 | 2.07 / 511.41 | 2 | 2 |
3 | 13 | 1730.16 | 18 | 14.34 | 2641 | 682 | 2.76 / 512.09 | 2 | 2 |
4 | 13 | 1175.96 | 18 | 14.49 | 1936 | 505 | 3.26 / 512.59 | 2 | 2 |
5 | 13 | 478.00 | 18 | 14.79 | 1016 | 270 | 3.53 / 512.87 | 2 | 2 |
6 | 13 | 45.04 | 18 | 15.00 | 394 | 106 | 3.64 / 512.97 | 2 | 2 |
7 | 8 | -0.36 | 165 | 14.99 | 313 | 774 | 4.41 / 513.75 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 29 | 14.93 | 491 | 213 | 0.21 / 505.16 | 2 | 2 |
2 | 7 | 2003.40 | 44 | 14.23 | 2990 | 1872 | 2.08 / 507.03 | 2 | 2 |
3 | 13 | 1595.28 | 18 | 14.36 | 2491 | 644 | 2.73 / 507.67 | 2 | 2 |
4 | 13 | 1055.16 | 18 | 14.53 | 1787 | 467 | 3.20 / 508.14 | 2 | 2 |
5 | 13 | 638.04 | 18 | 14.70 | 1238 | 328 | 3.52 / 508.47 | 2 | 2 |
6 | 13 | 21.92 | 18 | 15.02 | 350 | 95 | 3.62 / 508.56 | 2 | 2 |
7 | 8 | -0.32 | 165 | 14.99 | 311 | 769 | 4.39 / 509.33 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 29 | 14.93 | 511 | 221 | 0.22 / 500.60 | 2 | 2 |
2 | 7 | 2003.80 | 44 | 14.24 | 2982 | 1868 | 2.09 / 502.47 | 2 | 2 |
3 | 13 | 1597.96 | 18 | 14.37 | 2509 | 649 | 2.74 / 503.12 | 2 | 2 |
4 | 13 | 1059.04 | 18 | 14.53 | 1801 | 471 | 3.21 / 503.59 | 2 | 2 |
5 | 13 | 637.32 | 18 | 14.70 | 1239 | 328 | 3.54 / 503.92 | 2 | 2 |
6 | 13 | 44.40 | 18 | 15.00 | 389 | 105 | 3.64 / 504.02 | 2 | 2 |
7 | 8 | -0.16 | 165 | 14.98 | 309 | 764 | 4.41 / 504.78 | 2 | 2 |
8 | 14 | -0.16 | 35 | 14.97 | 310 | 162 | 4.57 / 504.95 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 28 | 14.93 | 507 | 212 | 0.21 / 496.17 | 2 | 2 |
2 | 7 | 2009.00 | 44 | 14.25 | 2953 | 1852 | 2.06 / 498.02 | 2 | 2 |
3 | 13 | 1615.00 | 18 | 14.38 | 2513 | 650 | 2.71 / 498.67 | 2 | 2 |
4 | 13 | 1065.36 | 18 | 14.53 | 1800 | 471 | 3.18 / 499.14 | 2 | 2 |
5 | 13 | 650.52 | 18 | 14.70 | 1253 | 332 | 3.52 / 499.47 | 2 | 2 |
6 | 13 | 88.80 | 18 | 14.98 | 467 | 126 | 3.64 / 499.60 | 2 | 2 |
7 | 8 | -0.28 | 165 | 14.98 | 316 | 781 | 4.42 / 500.38 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 28 | 14.93 | 497 | 208 | 0.21 / 491.83 | 2 | 2 |
2 | 7 | 2003.68 | 44 | 14.24 | 2980 | 1867 | 2.07 / 493.70 | 2 | 2 |
3 | 13 | 1594.44 | 18 | 14.37 | 2508 | 649 | 2.72 / 494.35 | 2 | 2 |
4 | 13 | 1056.48 | 18 | 14.53 | 1776 | 464 | 3.19 / 494.81 | 2 | 2 |
5 | 13 | 499.04 | 18 | 14.78 | 1045 | 278 | 3.47 / 495.09 | 2 | 2 |
6 | 13 | 20.84 | 18 | 15.02 | 345 | 93 | 3.56 / 495.19 | 2 | 2 |
7 | 8 | -0.24 | 165 | 14.99 | 311 | 769 | 4.33 / 495.95 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 29 | 14.94 | 494 | 214 | 0.21 / 487.43 | 2 | 2 |
2 | 7 | 2002.56 | 44 | 14.25 | 2957 | 1854 | 2.07 / 489.29 | 2 | 2 |
3 | 13 | 1592.28 | 18 | 14.38 | 2492 | 645 | 2.71 / 489.93 | 2 | 2 |
4 | 13 | 1185.60 | 18 | 14.49 | 1920 | 501 | 3.21 / 490.43 | 2 | 2 |
5 | 13 | 605.12 | 18 | 14.73 | 1186 | 314 | 3.53 / 490.75 | 2 | 2 |
6 | 13 | 69.36 | 18 | 14.99 | 427 | 115 | 3.64 / 490.86 | 2 | 2 |
7 | 8 | 0.00 | 165 | 14.99 | 309 | 764 | 4.41 / 491.63 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 29 | 14.93 | 507 | 220 | 0.22 / 483.15 | 2 | 2 |
2 | 7 | 2005.24 | 44 | 14.25 | 2968 | 1861 | 2.08 / 485.01 | 2 | 2 |
3 | 13 | 1610.36 | 18 | 14.37 | 2538 | 656 | 2.74 / 485.66 | 2 | 2 |
4 | 13 | 1192.64 | 18 | 14.48 | 1956 | 510 | 3.25 / 486.17 | 2 | 2 |
5 | 13 | 486.68 | 18 | 14.79 | 1033 | 275 | 3.52 / 486.45 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.00 | 311 | 770 | 4.29 / 487.22 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 29 | 14.93 | 499 | 216 | 0.22 / 478.70 | 2 | 2 |
2 | 7 | 2007.12 | 44 | 14.25 | 2976 | 1866 | 2.08 / 480.57 | 2 | 2 |
3 | 13 | 1734.16 | 18 | 14.34 | 2685 | 693 | 2.78 / 481.26 | 2 | 2 |
4 | 13 | 1161.76 | 18 | 14.51 | 1895 | 495 | 3.27 / 481.75 | 2 | 2 |
5 | 13 | 592.48 | 18 | 14.74 | 1161 | 308 | 3.58 / 482.06 | 2 | 2 |
6 | 13 | 33.96 | 18 | 15.01 | 368 | 99 | 3.68 / 482.16 | 2 | 2 |
7 | 8 | -0.12 | 165 | 14.99 | 309 | 764 | 4.44 / 482.93 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 28 | 14.94 | 496 | 207 | 0.21 / 474.19 | 2 | 2 |
2 | 7 | 2007.56 | 44 | 14.24 | 2991 | 1874 | 2.08 / 476.06 | 2 | 2 |
3 | 13 | 1729.56 | 18 | 14.34 | 2649 | 684 | 2.77 / 476.74 | 2 | 2 |
4 | 13 | 1166.72 | 18 | 14.50 | 1919 | 501 | 3.27 / 477.25 | 2 | 2 |
5 | 13 | 727.96 | 18 | 14.67 | 1351 | 357 | 3.62 / 477.60 | 2 | 2 |
6 | 13 | 56.52 | 18 | 15.00 | 410 | 111 | 3.73 / 477.71 | 2 | 2 |
7 | 8 | -0.28 | 165 | 14.99 | 312 | 772 | 4.51 / 478.48 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 28 | 14.93 | 500 | 209 | 0.21 / 469.75 | 2 | 2 |
2 | 7 | 2001.84 | 45 | 14.25 | 2977 | 1909 | 2.12 / 471.66 | 2 | 2 |
3 | 13 | 1721.80 | 18 | 14.34 | 2652 | 685 | 2.80 / 472.35 | 2 | 2 |
4 | 13 | 1159.76 | 18 | 14.51 | 1925 | 503 | 3.31 / 472.85 | 2 | 2 |
5 | 13 | 726.04 | 18 | 14.67 | 1364 | 360 | 3.67 / 473.21 | 2 | 2 |
6 | 8 | -0.32 | 165 | 15.00 | 311 | 770 | 4.44 / 473.98 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 28 | 14.94 | 505 | 211 | 0.21 / 465.36 | 2 | 2 |
2 | 7 | 2004.36 | 44 | 14.25 | 2972 | 1863 | 2.07 / 467.23 | 2 | 2 |
3 | 13 | 1725.48 | 18 | 14.34 | 2701 | 697 | 2.77 / 467.92 | 2 | 2 |
4 | 13 | 1032.36 | 18 | 14.55 | 1774 | 465 | 3.24 / 468.39 | 2 | 2 |
5 | 13 | 484.72 | 18 | 14.79 | 1031 | 274 | 3.51 / 468.66 | 2 | 2 |
6 | 13 | 47.56 | 18 | 15.01 | 399 | 108 | 3.62 / 468.77 | 2 | 2 |
7 | 8 | -0.12 | 165 | 14.99 | 313 | 774 | 4.39 / 469.54 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 28 | 14.94 | 493 | 206 | 0.21 / 461.03 | 2 | 2 |
2 | 7 | 2004.24 | 44 | 14.24 | 2988 | 1872 | 2.08 / 462.91 | 2 | 2 |
3 | 13 | 1587.96 | 18 | 14.38 | 2501 | 647 | 2.73 / 463.55 | 2 | 2 |
4 | 13 | 1177.36 | 18 | 14.48 | 1952 | 509 | 3.23 / 464.06 | 2 | 2 |
5 | 13 | 605.32 | 18 | 14.73 | 1192 | 316 | 3.55 / 464.38 | 2 | 2 |
6 | 8 | -0.36 | 165 | 15.00 | 312 | 772 | 4.32 / 465.15 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 28 | 14.95 | 518 | 217 | 0.22 / 456.64 | 2 | 2 |
2 | 7 | 2006.04 | 44 | 14.26 | 2947 | 1849 | 2.07 / 458.49 | 2 | 2 |
3 | 13 | 1602.08 | 18 | 14.39 | 2463 | 638 | 2.70 / 459.13 | 2 | 2 |
4 | 13 | 1183.68 | 18 | 14.49 | 1940 | 506 | 3.21 / 459.64 | 2 | 2 |
5 | 13 | 613.76 | 18 | 14.73 | 1198 | 318 | 3.53 / 459.95 | 2 | 2 |
6 | 13 | 37.28 | 18 | 15.02 | 372 | 101 | 3.63 / 460.05 | 2 | 2 |
7 | 8 | -0.16 | 165 | 14.99 | 313 | 774 | 4.40 / 460.83 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 28 | 14.95 | 492 | 206 | 0.21 / 452.35 | 2 | 2 |
2 | 7 | 2002.48 | 44 | 14.24 | 2996 | 1877 | 2.08 / 454.23 | 2 | 2 |
3 | 13 | 1599.52 | 18 | 14.39 | 2487 | 644 | 2.73 / 454.87 | 2 | 2 |
4 | 13 | 1185.72 | 18 | 14.49 | 1961 | 511 | 3.24 / 455.38 | 2 | 2 |
5 | 13 | 482.44 | 18 | 14.79 | 1028 | 274 | 3.51 / 455.66 | 2 | 2 |
6 | 8 | -0.20 | 165 | 15.00 | 311 | 770 | 4.28 / 456.43 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 28 | 14.95 | 507 | 212 | 0.21 / 447.84 | 2 | 2 |
2 | 7 | 2003.88 | 44 | 14.24 | 2996 | 1877 | 2.09 / 449.72 | 2 | 2 |
3 | 13 | 1724.96 | 18 | 14.34 | 2676 | 691 | 2.78 / 450.41 | 2 | 2 |
4 | 13 | 1291.68 | 18 | 14.45 | 2080 | 541 | 3.32 / 450.95 | 2 | 2 |
5 | 13 | 582.60 | 18 | 14.74 | 1166 | 309 | 3.63 / 451.26 | 2 | 2 |
6 | 13 | 66.32 | 18 | 15.00 | 433 | 117 | 3.75 / 451.37 | 2 | 2 |
7 | 8 | -0.20 | 165 | 15.00 | 311 | 770 | 4.52 / 452.14 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 28 | 14.95 | 485 | 203 | 0.20 / 443.47 | 2 | 2 |
2 | 7 | 2002.96 | 44 | 14.24 | 2993 | 1875 | 2.08 / 445.35 | 2 | 2 |
3 | 13 | 1589.80 | 18 | 14.39 | 2482 | 643 | 2.72 / 445.99 | 2 | 2 |
4 | 13 | 1304.48 | 18 | 14.44 | 2132 | 554 | 3.28 / 446.55 | 2 | 2 |
5 | 13 | 573.04 | 18 | 14.74 | 1159 | 308 | 3.58 / 446.85 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.00 | 312 | 772 | 4.36 / 447.63 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 28 | 14.94 | 503 | 210 | 0.21 / 438.82 | 2 | 2 |
2 | 7 | 2002.76 | 44 | 14.25 | 2979 | 1868 | 2.08 / 440.69 | 2 | 2 |
3 | 13 | 1724.64 | 18 | 14.35 | 2660 | 687 | 2.77 / 441.37 | 2 | 2 |
4 | 13 | 1145.56 | 18 | 14.51 | 1896 | 495 | 3.26 / 441.87 | 2 | 2 |
5 | 13 | 712.56 | 18 | 14.69 | 1332 | 352 | 3.61 / 442.22 | 2 | 2 |
6 | 13 | 56.96 | 18 | 15.01 | 414 | 112 | 3.72 / 442.33 | 2 | 2 |
7 | 8 | -0.20 | 165 | 15.00 | 313 | 775 | 4.50 / 443.11 | 2 | 2 |
8 | 14 | -0.20 | 35 | 14.98 | 312 | 164 | 4.66 / 443.27 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 28 | 14.94 | 496 | 207 | 0.21 / 434.51 | 2 | 2 |
2 | 7 | 2003.64 | 44 | 14.25 | 2973 | 1864 | 2.07 / 436.38 | 2 | 2 |
3 | 13 | 1584.16 | 18 | 14.39 | 2491 | 645 | 2.72 / 437.02 | 2 | 2 |
4 | 13 | 1060.16 | 18 | 14.55 | 1782 | 467 | 3.18 / 437.49 | 2 | 2 |
5 | 13 | 383.16 | 18 | 14.85 | 892 | 238 | 3.42 / 437.73 | 2 | 2 |
6 | 13 | 57.68 | 18 | 15.01 | 411 | 111 | 3.53 / 437.84 | 2 | 2 |
7 | 8 | -0.40 | 165 | 15.00 | 311 | 770 | 4.30 / 438.61 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 28 | 14.95 | 510 | 213 | 0.21 / 430.15 | 2 | 2 |
2 | 7 | 2004.68 | 44 | 14.25 | 2957 | 1854 | 2.07 / 432.00 | 2 | 2 |
3 | 13 | 1467.96 | 18 | 14.44 | 2287 | 594 | 2.66 / 432.60 | 2 | 2 |
4 | 13 | 1201.48 | 18 | 14.49 | 1969 | 514 | 3.18 / 433.11 | 2 | 2 |
5 | 13 | 624.12 | 18 | 14.73 | 1188 | 315 | 3.49 / 433.43 | 2 | 2 |
6 | 13 | 74.04 | 18 | 14.99 | 434 | 117 | 3.61 / 433.54 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.00 | 308 | 762 | 4.37 / 434.31 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 28 | 14.94 | 509 | 213 | 0.21 / 425.83 | 2 | 2 |
2 | 7 | 2004.48 | 44 | 14.25 | 2964 | 1858 | 2.07 / 427.69 | 2 | 2 |
3 | 13 | 1592.92 | 18 | 14.39 | 2474 | 641 | 2.71 / 428.33 | 2 | 2 |
4 | 13 | 1047.68 | 18 | 14.55 | 1751 | 459 | 3.17 / 428.79 | 2 | 2 |
5 | 13 | 502.20 | 18 | 14.79 | 1033 | 275 | 3.45 / 429.06 | 2 | 2 |
6 | 13 | 53.56 | 18 | 15.02 | 388 | 105 | 3.55 / 429.17 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.00 | 310 | 767 | 4.32 / 429.94 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 28 | 14.95 | 487 | 204 | 0.20 / 421.34 | 2 | 2 |
2 | 7 | 2006.00 | 44 | 14.24 | 3004 | 1882 | 2.09 / 423.22 | 2 | 2 |
3 | 13 | 1738.20 | 18 | 14.35 | 2686 | 694 | 2.78 / 423.91 | 2 | 2 |
4 | 13 | 1180.76 | 18 | 14.50 | 1958 | 511 | 3.29 / 424.43 | 2 | 2 |
5 | 13 | 608.16 | 18 | 14.73 | 1196 | 317 | 3.61 / 424.74 | 2 | 2 |
6 | 13 | 39.68 | 18 | 15.02 | 384 | 104 | 3.71 / 424.85 | 2 | 2 |
7 | 8 | 0.00 | 165 | 14.99 | 312 | 772 | 4.48 / 425.62 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 28 | 14.96 | 476 | 199 | 0.20 / 416.95 | 2 | 2 |
2 | 7 | 2003.16 | 44 | 14.24 | 2997 | 1878 | 2.08 / 418.83 | 2 | 2 |
3 | 13 | 1585.56 | 18 | 14.39 | 2501 | 648 | 2.72 / 419.48 | 2 | 2 |
4 | 13 | 1157.12 | 18 | 14.50 | 1930 | 504 | 3.23 / 419.98 | 2 | 2 |
5 | 13 | 454.28 | 18 | 14.81 | 994 | 265 | 3.49 / 420.25 | 2 | 2 |
6 | 13 | 73.40 | 18 | 14.99 | 442 | 119 | 3.61 / 420.37 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.00 | 311 | 770 | 4.38 / 421.14 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 28 | 14.95 | 504 | 211 | 0.21 / 412.33 | 2 | 2 |
2 | 7 | 2007.36 | 44 | 14.24 | 2994 | 1876 | 2.09 / 414.21 | 2 | 2 |
3 | 13 | 1589.52 | 18 | 14.39 | 2489 | 645 | 2.73 / 414.86 | 2 | 2 |
4 | 13 | 1049.20 | 18 | 14.55 | 1776 | 465 | 3.20 / 415.32 | 2 | 2 |
5 | 13 | 491.80 | 18 | 14.79 | 1038 | 276 | 3.47 / 415.60 | 2 | 2 |
6 | 13 | 54.28 | 18 | 15.01 | 415 | 112 | 3.59 / 415.71 | 2 | 2 |
7 | 13 | 34.24 | 18 | 15.01 | 380 | 103 | 3.69 / 415.81 | 2 | 2 |
8 | 8 | -0.08 | 165 | 14.99 | 314 | 777 | 4.46 / 416.59 | 2 | 2 |
9 | 14 | -0.08 | 35 | 14.97 | 313 | 164 | 4.63 / 416.75 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 28 | 14.95 | 497 | 208 | 0.21 / 407.76 | 2 | 2 |
2 | 7 | 2006.00 | 44 | 14.25 | 2972 | 1863 | 2.07 / 409.63 | 2 | 2 |
3 | 13 | 1597.64 | 18 | 14.39 | 2492 | 645 | 2.72 / 410.27 | 2 | 2 |
4 | 13 | 1180.08 | 18 | 14.49 | 1949 | 508 | 3.23 / 410.78 | 2 | 2 |
5 | 13 | 599.12 | 18 | 14.73 | 1184 | 314 | 3.54 / 411.10 | 2 | 2 |
6 | 13 | 36.52 | 18 | 15.02 | 375 | 101 | 3.64 / 411.20 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.00 | 308 | 762 | 4.40 / 411.96 | 2 | 2 |
8 | 14 | 0.08 | 35 | 14.98 | 313 | 164 | 4.57 / 412.12 | 2 | 2 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 28 | 14.97 | 487 | 204 | 0.20 / 403.41 | 2 | 2 |
2 | 7 | 2006.68 | 44 | 14.25 | 2979 | 1868 | 2.07 / 405.28 | 2 | 2 |
3 | 13 | 1593.32 | 18 | 14.40 | 2471 | 640 | 2.71 / 405.92 | 2 | 2 |
4 | 13 | 1179.12 | 18 | 14.50 | 1906 | 497 | 3.21 / 406.42 | 2 | 2 |
5 | 13 | 472.44 | 18 | 14.80 | 1002 | 267 | 3.48 / 406.69 | 2 | 2 |
6 | 13 | 42.60 | 18 | 15.02 | 388 | 105 | 3.58 / 406.79 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.00 | 309 | 765 | 4.35 / 407.56 | 2 | 2 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 28 | 14.96 | 485 | 203 | 0.20 / 399.05 | 2 | 2 |
2 | 7 | 2006.36 | 44 | 14.24 | 2981 | 1868 | 2.07 / 400.92 | 2 | 2 |
3 | 13 | 1604.92 | 18 | 14.39 | 2508 | 650 | 2.72 / 401.57 | 2 | 2 |
4 | 13 | 1178.44 | 18 | 14.50 | 1943 | 507 | 3.23 / 402.08 | 2 | 2 |
5 | 13 | 469.08 | 18 | 14.81 | 1009 | 269 | 3.50 / 402.35 | 2 | 2 |
6 | 13 | 44.60 | 18 | 15.02 | 393 | 106 | 3.60 / 402.45 | 2 | 2 |
7 | 8 | -0.40 | 165 | 15.01 | 306 | 758 | 4.36 / 403.21 | 2 | 2 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 28 | 14.96 | 495 | 207 | 0.21 / 394.64 | 2 | 2 |
2 | 7 | 2014.84 | 44 | 14.24 | 3017 | 1890 | 2.10 / 396.53 | 2 | 2 |
3 | 13 | 1606.96 | 18 | 14.38 | 2511 | 650 | 2.75 / 397.18 | 2 | 2 |
4 | 13 | 1059.24 | 18 | 14.55 | 1799 | 471 | 3.22 / 397.65 | 2 | 2 |
5 | 13 | 642.56 | 18 | 14.72 | 1238 | 328 | 3.55 / 397.98 | 2 | 2 |
6 | 13 | 47.84 | 18 | 15.01 | 396 | 107 | 3.65 / 398.08 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.00 | 310 | 767 | 4.42 / 398.85 | 2 | 2 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 28 | 14.96 | 503 | 211 | 0.21 / 390.11 | 2 | 2 |
2 | 7 | 2003.40 | 44 | 14.25 | 2984 | 1871 | 2.08 / 391.98 | 2 | 2 |
3 | 13 | 1594.44 | 18 | 14.39 | 2488 | 644 | 2.73 / 392.63 | 2 | 2 |
4 | 13 | 1173.84 | 18 | 14.50 | 1937 | 506 | 3.23 / 393.13 | 2 | 2 |
5 | 13 | 607.00 | 18 | 14.74 | 1197 | 318 | 3.55 / 393.45 | 2 | 2 |
6 | 13 | 51.64 | 18 | 15.01 | 404 | 109 | 3.66 / 393.56 | 2 | 2 |
7 | 13 | 32.40 | 18 | 15.02 | 373 | 101 | 3.76 / 393.66 | 2 | 2 |
8 | 8 | 0.16 | 165 | 15.00 | 310 | 767 | 4.53 / 394.43 | 2 | 2 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 28 | 14.96 | 489 | 205 | 0.20 / 385.68 | 2 | 2 |
2 | 7 | 2004.16 | 44 | 14.25 | 2998 | 1880 | 2.08 / 387.56 | 2 | 2 |
3 | 13 | 1741.60 | 18 | 14.35 | 2658 | 687 | 2.77 / 388.25 | 2 | 2 |
4 | 13 | 1156.04 | 18 | 14.51 | 1920 | 501 | 3.27 / 388.75 | 2 | 2 |
5 | 13 | 466.28 | 18 | 14.82 | 1001 | 267 | 3.54 / 389.02 | 2 | 2 |
6 | 13 | 89.60 | 18 | 14.99 | 469 | 127 | 3.67 / 389.14 | 2 | 2 |
7 | 8 | -0.24 | 165 | 15.00 | 307 | 760 | 4.43 / 389.90 | 2 | 2 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 28 | 14.95 | 501 | 210 | 0.21 / 381.25 | 2 | 2 |
2 | 7 | 2005.24 | 44 | 14.25 | 2989 | 1874 | 2.08 / 383.13 | 2 | 2 |
3 | 13 | 1589.72 | 18 | 14.40 | 2484 | 644 | 2.73 / 383.77 | 2 | 2 |
4 | 13 | 1181.08 | 18 | 14.51 | 1929 | 504 | 3.23 / 384.28 | 2 | 2 |
5 | 13 | 611.84 | 18 | 14.74 | 1195 | 317 | 3.55 / 384.59 | 2 | 2 |
6 | 13 | 75.48 | 18 | 15.00 | 450 | 121 | 3.67 / 384.71 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.00 | 308 | 762 | 4.43 / 385.48 | 2 | 2 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 28 | 14.96 | 502 | 210 | 0.21 / 376.73 | 2 | 2 |
2 | 7 | 2005.56 | 44 | 14.25 | 2979 | 1868 | 2.08 / 378.60 | 2 | 2 |
3 | 13 | 1591.92 | 18 | 14.40 | 2467 | 639 | 2.72 / 379.24 | 2 | 2 |
4 | 13 | 1050.84 | 18 | 14.56 | 1779 | 466 | 3.18 / 379.70 | 2 | 2 |
5 | 13 | 626.48 | 18 | 14.74 | 1196 | 317 | 3.50 / 380.02 | 2 | 2 |
6 | 13 | 50.00 | 18 | 15.02 | 388 | 105 | 3.61 / 380.13 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.00 | 305 | 755 | 4.36 / 380.88 | 2 | 2 |
8 | 14 | 0.16 | 35 | 14.97 | 309 | 162 | 4.52 / 381.04 | 2 | 2 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 28 | 14.96 | 493 | 207 | 0.21 / 372.30 | 2 | 2 |
2 | 7 | 2008.72 | 44 | 14.24 | 3005 | 1883 | 2.09 / 374.18 | 2 | 2 |
3 | 13 | 1607.68 | 18 | 14.39 | 2509 | 650 | 2.74 / 374.83 | 2 | 2 |
4 | 13 | 1182.64 | 18 | 14.49 | 1960 | 511 | 3.25 / 375.34 | 2 | 2 |
5 | 13 | 609.72 | 18 | 14.74 | 1205 | 320 | 3.57 / 375.66 | 2 | 2 |
6 | 13 | 38.64 | 18 | 15.02 | 378 | 102 | 3.67 / 375.76 | 2 | 2 |
7 | 8 | -0.08 | 165 | 15.00 | 306 | 757 | 4.43 / 376.52 | 2 | 2 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 28 | 14.95 | 503 | 211 | 0.21 / 367.83 | 2 | 2 |
2 | 7 | 2003.68 | 44 | 14.25 | 3001 | 1882 | 2.09 / 369.71 | 2 | 2 |
3 | 13 | 1728.04 | 18 | 14.35 | 2680 | 692 | 2.78 / 370.41 | 2 | 2 |
4 | 13 | 1165.28 | 18 | 14.51 | 1925 | 503 | 3.29 / 370.91 | 2 | 2 |
5 | 13 | 606.16 | 18 | 14.74 | 1200 | 318 | 3.61 / 371.23 | 2 | 2 |
6 | 13 | 38.76 | 18 | 15.02 | 378 | 102 | 3.71 / 371.33 | 2 | 2 |
7 | 8 | 0.36 | 165 | 15.01 | 308 | 763 | 4.47 / 372.09 | 2 | 2 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 28 | 14.95 | 501 | 210 | 0.21 / 363.35 | 2 | 2 |
2 | 7 | 2004.20 | 44 | 14.26 | 2953 | 1853 | 2.06 / 365.20 | 2 | 2 |
3 | 13 | 1727.16 | 18 | 14.35 | 2657 | 686 | 2.75 / 365.89 | 2 | 2 |
4 | 13 | 1052.48 | 18 | 14.56 | 1776 | 465 | 3.21 / 366.35 | 2 | 2 |
5 | 13 | 504.16 | 18 | 14.80 | 1056 | 281 | 3.50 / 366.63 | 2 | 2 |
6 | 13 | 46.96 | 18 | 15.02 | 401 | 108 | 3.60 / 366.74 | 2 | 2 |
7 | 13 | 29.56 | 18 | 15.02 | 375 | 101 | 3.71 / 366.84 | 2 | 2 |
8 | 8 | -0.36 | 165 | 15.00 | 314 | 777 | 4.48 / 367.62 | 2 | 2 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 28 | 14.96 | 476 | 199 | 0.20 / 358.81 | 2 | 2 |
2 | 7 | 2006.24 | 44 | 14.25 | 2982 | 1870 | 2.07 / 360.68 | 2 | 2 |
3 | 13 | 1734.20 | 18 | 14.36 | 2647 | 684 | 2.75 / 361.37 | 2 | 2 |
4 | 13 | 1303.52 | 18 | 14.46 | 2130 | 554 | 3.31 / 361.92 | 2 | 2 |
5 | 13 | 712.64 | 18 | 14.69 | 1331 | 352 | 3.66 / 362.27 | 2 | 2 |
6 | 13 | 30.60 | 18 | 15.02 | 364 | 98 | 3.76 / 362.37 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.00 | 310 | 767 | 4.53 / 363.14 | 2 | 2 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 28 | 14.95 | 493 | 206 | 0.21 / 354.42 | 2 | 2 |
2 | 7 | 2002.56 | 44 | 14.26 | 2971 | 1864 | 2.07 / 356.29 | 2 | 2 |
3 | 13 | 1596.76 | 18 | 14.40 | 2497 | 647 | 2.72 / 356.93 | 2 | 2 |
4 | 13 | 1179.76 | 18 | 14.50 | 1936 | 505 | 3.22 / 357.44 | 2 | 2 |
5 | 13 | 618.48 | 18 | 14.74 | 1197 | 318 | 3.54 / 357.76 | 2 | 2 |
6 | 13 | 34.40 | 18 | 15.03 | 366 | 99 | 3.64 / 357.85 | 2 | 2 |
7 | 8 | -0.12 | 165 | 15.01 | 306 | 758 | 4.40 / 358.61 | 2 | 2 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 28 | 14.95 | 500 | 209 | 0.21 / 349.99 | 2 | 2 |
2 | 7 | 2005.64 | 44 | 14.25 | 2999 | 1880 | 2.09 / 351.87 | 2 | 2 |
3 | 13 | 1596.32 | 18 | 14.41 | 2473 | 641 | 2.73 / 352.51 | 2 | 2 |
4 | 13 | 1181.72 | 18 | 14.51 | 1956 | 511 | 3.24 / 353.03 | 2 | 2 |
5 | 13 | 611.76 | 18 | 14.74 | 1199 | 318 | 3.56 / 353.34 | 2 | 2 |
6 | 13 | 71.04 | 18 | 15.01 | 430 | 116 | 3.68 / 353.46 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.01 | 305 | 755 | 4.43 / 354.22 | 2 | 2 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 28 | 14.96 | 510 | 214 | 0.21 / 345.55 | 2 | 2 |
2 | 7 | 2003.48 | 44 | 14.26 | 2985 | 1873 | 2.09 / 347.42 | 2 | 2 |
3 | 13 | 1607.52 | 18 | 14.38 | 2521 | 653 | 2.74 / 348.08 | 2 | 2 |
4 | 13 | 1199.04 | 18 | 14.50 | 1981 | 517 | 3.26 / 348.59 | 2 | 2 |
5 | 13 | 627.40 | 18 | 14.73 | 1223 | 324 | 3.58 / 348.92 | 2 | 2 |
6 | 13 | 38.16 | 18 | 15.02 | 376 | 102 | 3.68 / 349.02 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.00 | 309 | 765 | 4.45 / 349.78 | 2 | 2 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 28 | 14.95 | 500 | 209 | 0.21 / 341.24 | 2 | 2 |
2 | 7 | 2003.88 | 44 | 14.26 | 2985 | 1873 | 2.08 / 343.11 | 2 | 2 |
3 | 13 | 1728.60 | 18 | 14.36 | 2671 | 690 | 2.77 / 343.81 | 2 | 2 |
4 | 13 | 1148.88 | 18 | 14.52 | 1906 | 498 | 3.27 / 344.30 | 2 | 2 |
5 | 13 | 467.80 | 18 | 14.82 | 995 | 265 | 3.54 / 344.57 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.02 | 310 | 768 | 4.30 / 345.34 | 2 | 2 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 28 | 14.95 | 502 | 210 | 0.21 / 336.77 | 2 | 2 |
2 | 7 | 2003.60 | 44 | 14.26 | 2982 | 1871 | 2.08 / 338.65 | 2 | 2 |
3 | 13 | 1734.76 | 18 | 14.37 | 2659 | 688 | 2.77 / 339.33 | 2 | 2 |
4 | 13 | 1173.12 | 18 | 14.51 | 1937 | 506 | 3.27 / 339.84 | 2 | 2 |
5 | 13 | 609.04 | 18 | 14.76 | 1191 | 316 | 3.59 / 340.16 | 2 | 2 |
6 | 13 | 37.32 | 18 | 15.03 | 377 | 102 | 3.69 / 340.26 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.00 | 313 | 775 | 4.47 / 341.03 | 2 | 2 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 29 | 14.94 | 513 | 222 | 0.22 / 332.41 | 2 | 2 |
2 | 7 | 2002.80 | 44 | 14.25 | 2982 | 1870 | 2.09 / 334.28 | 2 | 2 |
3 | 13 | 1591.92 | 18 | 14.40 | 2475 | 642 | 2.73 / 334.92 | 2 | 2 |
4 | 13 | 1166.96 | 18 | 14.51 | 1933 | 505 | 3.24 / 335.42 | 2 | 2 |
5 | 13 | 460.16 | 18 | 14.82 | 991 | 264 | 3.50 / 335.69 | 2 | 2 |
6 | 13 | 37.64 | 18 | 15.03 | 377 | 102 | 3.60 / 335.79 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.01 | 313 | 775 | 4.38 / 336.56 | 2 | 2 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 29 | 14.95 | 496 | 215 | 0.22 / 327.93 | 2 | 2 |
2 | 7 | 2001.76 | 44 | 14.27 | 2972 | 1866 | 2.08 / 329.79 | 2 | 2 |
3 | 13 | 1595.92 | 18 | 14.42 | 2425 | 629 | 2.71 / 330.42 | 2 | 2 |
4 | 13 | 1063.56 | 18 | 14.56 | 1791 | 469 | 3.18 / 330.89 | 2 | 2 |
5 | 13 | 511.04 | 18 | 14.81 | 1060 | 283 | 3.46 / 331.17 | 2 | 2 |
6 | 13 | 12.24 | 18 | 15.05 | 325 | 88 | 3.55 / 331.26 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.01 | 306 | 758 | 4.31 / 332.02 | 2 | 2 |
8 | 14 | -0.04 | 35 | 14.99 | 316 | 166 | 4.47 / 332.18 | 2 | 2 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 28 | 14.95 | 501 | 210 | 0.21 / 323.47 | 2 | 2 |
2 | 7 | 2003.20 | 44 | 14.27 | 2949 | 1852 | 2.06 / 325.32 | 2 | 2 |
3 | 13 | 1734.52 | 18 | 14.37 | 2659 | 688 | 2.75 / 326.01 | 2 | 2 |
4 | 13 | 1168.08 | 18 | 14.52 | 1921 | 502 | 3.25 / 326.51 | 2 | 2 |
5 | 13 | 463.20 | 18 | 14.83 | 990 | 264 | 3.52 / 326.78 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.02 | 310 | 768 | 4.28 / 327.55 | 2 | 2 |
7 | 14 | 0.16 | 35 | 15.00 | 311 | 163 | 4.45 / 327.71 | 2 | 2 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 28 | 14.95 | 512 | 214 | 0.21 / 319.22 | 2 | 2 |
2 | 7 | 2003.80 | 44 | 14.27 | 2985 | 1874 | 2.09 / 321.09 | 2 | 2 |
3 | 13 | 1584.40 | 18 | 14.42 | 2475 | 642 | 2.73 / 321.73 | 2 | 2 |
4 | 13 | 1157.24 | 18 | 14.52 | 1921 | 502 | 3.23 / 322.23 | 2 | 2 |
5 | 13 | 464.12 | 18 | 14.83 | 994 | 265 | 3.50 / 322.50 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.02 | 308 | 763 | 4.26 / 323.26 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 28 | 14.96 | 493 | 207 | 0.21 / 314.91 | 2 | 2 |
2 | 7 | 2002.00 | 44 | 14.27 | 2990 | 1877 | 2.08 / 316.78 | 2 | 2 |
3 | 13 | 1721.08 | 18 | 14.37 | 2687 | 695 | 2.78 / 317.48 | 2 | 2 |
4 | 13 | 1148.00 | 18 | 14.54 | 1905 | 499 | 3.28 / 317.98 | 2 | 2 |
5 | 13 | 444.52 | 18 | 14.84 | 973 | 260 | 3.54 / 318.24 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.02 | 309 | 766 | 4.30 / 319.00 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 28 | 14.96 | 495 | 207 | 0.21 / 310.63 | 2 | 2 |
2 | 7 | 2004.68 | 44 | 14.28 | 2980 | 1872 | 2.08 / 312.50 | 2 | 2 |
3 | 13 | 1608.28 | 18 | 14.41 | 2501 | 649 | 2.73 / 313.15 | 2 | 2 |
4 | 13 | 1188.00 | 18 | 14.52 | 1964 | 513 | 3.24 / 313.66 | 2 | 2 |
5 | 13 | 487.32 | 18 | 14.83 | 1023 | 273 | 3.51 / 313.93 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.03 | 308 | 764 | 4.28 / 314.70 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 28 | 14.96 | 526 | 220 | 0.22 / 306.41 | 2 | 2 |
2 | 7 | 2002.80 | 44 | 14.27 | 3007 | 1888 | 2.11 / 308.30 | 2 | 2 |
3 | 13 | 1456.76 | 18 | 14.46 | 2296 | 598 | 2.71 / 308.89 | 2 | 2 |
4 | 13 | 1054.32 | 18 | 14.58 | 1789 | 470 | 3.18 / 309.36 | 2 | 2 |
5 | 13 | 501.72 | 18 | 14.82 | 1052 | 281 | 3.46 / 309.64 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.02 | 313 | 776 | 4.23 / 310.42 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 28 | 14.97 | 527 | 221 | 0.22 / 301.98 | 2 | 2 |
2 | 7 | 2003.68 | 44 | 14.27 | 3005 | 1887 | 2.11 / 303.87 | 2 | 2 |
3 | 13 | 1605.20 | 18 | 14.42 | 2495 | 648 | 2.76 / 304.52 | 2 | 2 |
4 | 13 | 1056.60 | 18 | 14.58 | 1766 | 463 | 3.22 / 304.98 | 2 | 2 |
5 | 13 | 502.80 | 18 | 14.83 | 1040 | 278 | 3.50 / 305.26 | 2 | 2 |
6 | 8 | 0.44 | 165 | 15.03 | 309 | 766 | 4.26 / 306.02 | 2 | 2 |
7 | 14 | 0.44 | 35 | 15.01 | 315 | 165 | 4.43 / 306.19 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 28 | 14.97 | 503 | 211 | 0.21 / 297.68 | 2 | 2 |
2 | 7 | 2003.84 | 44 | 14.27 | 2988 | 1876 | 2.09 / 299.55 | 2 | 2 |
3 | 13 | 1606.20 | 18 | 14.42 | 2507 | 651 | 2.74 / 300.20 | 2 | 2 |
4 | 13 | 1196.32 | 18 | 14.53 | 1951 | 510 | 3.25 / 300.71 | 2 | 2 |
5 | 13 | 494.32 | 18 | 14.84 | 1034 | 276 | 3.52 / 300.99 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.03 | 310 | 769 | 4.29 / 301.76 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 28 | 14.97 | 487 | 204 | 0.20 / 293.44 | 2 | 2 |
2 | 7 | 2004.80 | 44 | 14.28 | 2985 | 1876 | 2.08 / 295.31 | 2 | 2 |
3 | 13 | 1599.32 | 18 | 14.43 | 2482 | 645 | 2.72 / 295.96 | 2 | 2 |
4 | 13 | 1044.72 | 18 | 14.59 | 1788 | 470 | 3.19 / 296.42 | 2 | 2 |
5 | 13 | 494.12 | 18 | 14.84 | 1040 | 278 | 3.47 / 296.70 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.04 | 308 | 764 | 4.24 / 297.47 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 28 | 14.99 | 507 | 213 | 0.21 / 288.96 | 2 | 2 |
2 | 7 | 2005.20 | 44 | 14.27 | 3012 | 1891 | 2.10 / 290.85 | 2 | 2 |
3 | 13 | 1736.88 | 18 | 14.38 | 2643 | 684 | 2.79 / 291.53 | 2 | 2 |
4 | 13 | 1166.28 | 18 | 14.55 | 1914 | 501 | 3.29 / 292.03 | 2 | 2 |
5 | 13 | 592.20 | 18 | 14.80 | 1166 | 311 | 3.60 / 292.34 | 2 | 2 |
6 | 13 | 71.88 | 18 | 15.04 | 443 | 120 | 3.72 / 292.46 | 2 | 2 |
7 | 8 | -0.08 | 165 | 15.03 | 310 | 769 | 4.49 / 293.23 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 27 | 15.00 | 508 | 206 | 0.21 / 284.38 | 2 | 2 |
2 | 7 | 2003.92 | 44 | 14.28 | 2984 | 1875 | 2.08 / 286.26 | 2 | 2 |
3 | 13 | 1603.44 | 18 | 14.43 | 2468 | 641 | 2.72 / 286.90 | 2 | 2 |
4 | 13 | 1058.00 | 18 | 14.59 | 1783 | 468 | 3.19 / 287.37 | 2 | 2 |
5 | 13 | 631.36 | 18 | 14.78 | 1222 | 325 | 3.52 / 287.69 | 2 | 2 |
6 | 13 | 80.48 | 18 | 15.04 | 444 | 120 | 3.64 / 287.81 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.04 | 308 | 764 | 4.40 / 288.58 | 2 | 2 |
8 | 14 | 0.20 | 35 | 15.02 | 312 | 164 | 4.56 / 288.74 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 27 | 15.00 | 491 | 199 | 0.20 / 280.19 | 2 | 2 |
2 | 7 | 2003.84 | 44 | 14.28 | 2991 | 1879 | 2.08 / 282.07 | 2 | 2 |
3 | 13 | 1465.20 | 18 | 14.48 | 2323 | 605 | 2.68 / 282.67 | 2 | 2 |
4 | 13 | 1052.24 | 18 | 14.60 | 1778 | 467 | 3.15 / 283.14 | 2 | 2 |
5 | 13 | 490.80 | 18 | 14.85 | 1029 | 275 | 3.43 / 283.41 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.06 | 308 | 765 | 4.19 / 284.18 | 2 | 2 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 27 | 15.00 | 505 | 205 | 0.20 / 275.80 | 2 | 2 |
2 | 7 | 2002.44 | 44 | 14.29 | 2984 | 1876 | 2.08 / 277.68 | 2 | 2 |
3 | 13 | 1601.32 | 18 | 14.45 | 2481 | 645 | 2.73 / 278.32 | 2 | 2 |
4 | 13 | 1185.84 | 18 | 14.55 | 1962 | 514 | 3.24 / 278.84 | 2 | 2 |
5 | 13 | 476.04 | 18 | 14.86 | 1019 | 273 | 3.51 / 279.11 | 2 | 2 |
6 | 13 | 40.60 | 18 | 15.07 | 385 | 104 | 3.62 / 279.22 | 2 | 2 |
7 | 8 | 0.44 | 165 | 15.05 | 311 | 772 | 4.39 / 279.99 | 2 | 2 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 27 | 15.00 | 520 | 211 | 0.21 / 271.39 | 2 | 2 |
2 | 7 | 2005.28 | 44 | 14.28 | 3009 | 1891 | 2.10 / 273.28 | 2 | 2 |
3 | 13 | 1582.28 | 18 | 14.45 | 2450 | 637 | 2.74 / 273.92 | 2 | 2 |
4 | 13 | 1167.68 | 18 | 14.56 | 1942 | 509 | 3.25 / 274.42 | 2 | 2 |
5 | 13 | 591.00 | 18 | 14.80 | 1179 | 314 | 3.56 / 274.74 | 2 | 2 |
6 | 13 | 14.68 | 18 | 15.09 | 338 | 92 | 3.65 / 274.83 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.05 | 309 | 767 | 4.42 / 275.60 | 2 | 2 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 27 | 15.00 | 505 | 205 | 0.20 / 267.00 | 2 | 2 |
2 | 7 | 2006.92 | 44 | 14.29 | 2992 | 1881 | 2.09 / 268.88 | 2 | 2 |
3 | 13 | 1588.20 | 18 | 14.44 | 2490 | 647 | 2.73 / 269.53 | 2 | 2 |
4 | 13 | 1164.60 | 18 | 14.56 | 1938 | 508 | 3.24 / 270.04 | 2 | 2 |
5 | 13 | 455.16 | 18 | 14.88 | 989 | 265 | 3.51 / 270.30 | 2 | 2 |
6 | 13 | 38.72 | 18 | 15.08 | 378 | 103 | 3.61 / 270.40 | 2 | 2 |
7 | 8 | 0.44 | 165 | 15.06 | 311 | 773 | 4.38 / 271.18 | 2 | 2 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 27 | 15.01 | 496 | 201 | 0.20 / 262.47 | 2 | 2 |
2 | 7 | 2005.96 | 44 | 14.29 | 2998 | 1885 | 2.09 / 264.36 | 2 | 2 |
3 | 13 | 1586.84 | 18 | 14.46 | 2495 | 649 | 2.74 / 265.00 | 2 | 2 |
4 | 13 | 1158.68 | 18 | 14.58 | 1914 | 502 | 3.24 / 265.51 | 2 | 2 |
5 | 13 | 338.16 | 18 | 14.94 | 829 | 223 | 3.46 / 265.73 | 2 | 2 |
6 | 13 | 94.20 | 18 | 15.05 | 475 | 129 | 3.59 / 265.86 | 2 | 2 |
7 | 8 | -0.08 | 165 | 15.06 | 311 | 773 | 4.36 / 266.63 | 2 | 2 |
8 | 14 | -0.08 | 35 | 15.04 | 313 | 165 | 4.53 / 266.80 | 2 | 2 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 27 | 15.02 | 508 | 206 | 0.21 / 257.92 | 2 | 2 |
2 | 7 | 2003.40 | 44 | 14.30 | 3011 | 1895 | 2.10 / 259.81 | 2 | 2 |
3 | 13 | 1583.88 | 18 | 14.46 | 2469 | 643 | 2.74 / 260.45 | 2 | 2 |
4 | 13 | 1036.48 | 18 | 14.63 | 1743 | 459 | 3.20 / 260.91 | 2 | 2 |
5 | 13 | 612.56 | 18 | 14.81 | 1200 | 320 | 3.52 / 261.23 | 2 | 2 |
6 | 13 | 37.52 | 18 | 15.09 | 377 | 102 | 3.62 / 261.33 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.07 | 310 | 771 | 4.40 / 262.11 | 2 | 2 |
8 | 14 | 0.16 | 35 | 15.05 | 311 | 164 | 4.56 / 262.27 | 2 | 2 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 27 | 15.03 | 487 | 198 | 0.20 / 253.60 | 2 | 2 |
2 | 7 | 2001.64 | 44 | 14.30 | 2987 | 1879 | 2.08 / 255.48 | 2 | 2 |
3 | 13 | 1594.84 | 18 | 14.46 | 2509 | 653 | 2.73 / 256.13 | 2 | 2 |
4 | 13 | 1037.48 | 18 | 14.65 | 1750 | 461 | 3.19 / 256.59 | 2 | 2 |
5 | 13 | 471.28 | 18 | 14.89 | 997 | 267 | 3.46 / 256.86 | 2 | 2 |
6 | 13 | 39.88 | 18 | 15.10 | 362 | 98 | 3.56 / 256.96 | 2 | 2 |
7 | 8 | 0.24 | 165 | 15.08 | 303 | 754 | 4.31 / 257.71 | 2 | 2 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 27 | 15.03 | 495 | 201 | 0.20 / 249.13 | 2 | 2 |
2 | 7 | 2005.20 | 44 | 14.30 | 2986 | 1879 | 2.08 / 251.01 | 2 | 2 |
3 | 13 | 1728.08 | 18 | 14.42 | 2673 | 694 | 2.77 / 251.70 | 2 | 2 |
4 | 13 | 1147.32 | 18 | 14.59 | 1922 | 505 | 3.28 / 252.21 | 2 | 2 |
5 | 13 | 583.48 | 18 | 14.84 | 1166 | 311 | 3.59 / 252.52 | 2 | 2 |
6 | 13 | 65.00 | 18 | 15.08 | 421 | 114 | 3.70 / 252.63 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.08 | 308 | 766 | 4.47 / 253.40 | 2 | 2 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 27 | 15.04 | 488 | 198 | 0.20 / 244.70 | 2 | 2 |
2 | 7 | 2004.04 | 44 | 14.30 | 2986 | 1879 | 2.08 / 246.57 | 2 | 2 |
3 | 13 | 1593.04 | 18 | 14.47 | 2490 | 649 | 2.73 / 247.22 | 2 | 2 |
4 | 13 | 1158.12 | 18 | 14.61 | 1902 | 500 | 3.23 / 247.72 | 2 | 2 |
5 | 13 | 573.72 | 18 | 14.84 | 1151 | 307 | 3.53 / 248.03 | 2 | 2 |
6 | 13 | 58.52 | 18 | 15.08 | 424 | 115 | 3.65 / 248.15 | 2 | 2 |
7 | 8 | 0.28 | 165 | 15.08 | 315 | 784 | 4.43 / 248.93 | 2 | 2 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 27 | 15.04 | 485 | 197 | 0.20 / 240.15 | 2 | 2 |
2 | 7 | 2002.68 | 44 | 14.30 | 2993 | 1883 | 2.08 / 242.03 | 2 | 2 |
3 | 13 | 1720.68 | 18 | 14.44 | 2674 | 695 | 2.78 / 242.73 | 2 | 2 |
4 | 13 | 1015.96 | 18 | 14.66 | 1743 | 460 | 3.24 / 243.19 | 2 | 2 |
5 | 13 | 464.80 | 18 | 14.90 | 1004 | 269 | 3.50 / 243.46 | 2 | 2 |
6 | 13 | 42.76 | 18 | 15.10 | 387 | 105 | 3.61 / 243.56 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.09 | 309 | 769 | 4.38 / 244.33 | 2 | 2 |
8 | 14 | -0.04 | 35 | 15.06 | 311 | 164 | 4.54 / 244.50 | 2 | 2 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 27 | 15.04 | 498 | 202 | 0.20 / 235.73 | 2 | 2 |
2 | 7 | 2002.12 | 45 | 14.31 | 2978 | 1918 | 2.12 / 237.64 | 2 | 2 |
3 | 13 | 1594.76 | 18 | 14.48 | 2482 | 647 | 2.77 / 238.29 | 2 | 2 |
4 | 13 | 1038.96 | 18 | 14.65 | 1754 | 463 | 3.23 / 238.75 | 2 | 2 |
5 | 13 | 608.04 | 18 | 14.83 | 1188 | 317 | 3.55 / 239.07 | 2 | 2 |
6 | 13 | 67.60 | 18 | 15.09 | 425 | 115 | 3.66 / 239.19 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.08 | 309 | 769 | 4.43 / 239.95 | 2 | 2 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 27 | 15.05 | 499 | 203 | 0.20 / 231.41 | 2 | 2 |
2 | 7 | 2001.92 | 44 | 14.31 | 2974 | 1873 | 2.08 / 233.28 | 2 | 2 |
3 | 13 | 1584.76 | 18 | 14.49 | 2456 | 641 | 2.72 / 233.92 | 2 | 2 |
4 | 13 | 1032.20 | 18 | 14.66 | 1736 | 458 | 3.17 / 234.38 | 2 | 2 |
5 | 13 | 464.88 | 18 | 14.91 | 996 | 267 | 3.44 / 234.65 | 2 | 2 |
6 | 13 | 43.44 | 18 | 15.11 | 392 | 107 | 3.55 / 234.76 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.09 | 308 | 767 | 4.31 / 235.52 | 2 | 2 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 27 | 15.06 | 492 | 200 | 0.20 / 227.07 | 2 | 2 |
2 | 7 | 2006.08 | 44 | 14.33 | 2965 | 1869 | 2.07 / 228.94 | 2 | 2 |
3 | 13 | 1469.16 | 18 | 14.53 | 2331 | 610 | 2.68 / 229.55 | 2 | 2 |
4 | 13 | 1050.68 | 18 | 14.65 | 1782 | 470 | 3.15 / 230.02 | 2 | 2 |
5 | 13 | 613.16 | 18 | 14.84 | 1197 | 320 | 3.47 / 230.34 | 2 | 2 |
6 | 13 | 39.04 | 18 | 15.11 | 380 | 103 | 3.57 / 230.44 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.09 | 307 | 764 | 4.34 / 231.21 | 2 | 2 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 27 | 15.05 | 510 | 207 | 0.21 / 222.77 | 2 | 2 |
2 | 7 | 2005.64 | 44 | 14.32 | 2998 | 1889 | 2.10 / 224.66 | 2 | 2 |
3 | 13 | 1585.32 | 18 | 14.49 | 2482 | 647 | 2.74 / 225.30 | 2 | 2 |
4 | 13 | 1021.84 | 18 | 14.67 | 1752 | 463 | 3.21 / 225.77 | 2 | 2 |
5 | 13 | 342.24 | 18 | 14.97 | 840 | 226 | 3.43 / 225.99 | 2 | 2 |
6 | 13 | 48.16 | 18 | 15.11 | 401 | 109 | 3.54 / 226.10 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.10 | 309 | 770 | 4.31 / 226.87 | 2 | 2 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 27 | 15.06 | 508 | 207 | 0.21 / 218.42 | 2 | 2 |
2 | 7 | 2003.92 | 44 | 14.33 | 2963 | 1868 | 2.07 / 220.29 | 2 | 2 |
3 | 13 | 1590.68 | 18 | 14.49 | 2489 | 649 | 2.72 / 220.94 | 2 | 2 |
4 | 13 | 1039.84 | 18 | 14.67 | 1771 | 468 | 3.19 / 221.41 | 2 | 2 |
5 | 13 | 480.36 | 18 | 14.91 | 1019 | 273 | 3.47 / 221.68 | 2 | 2 |
6 | 13 | 38.24 | 18 | 15.12 | 377 | 103 | 3.57 / 221.79 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.10 | 311 | 775 | 4.34 / 222.56 | 2 | 2 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 27 | 15.06 | 486 | 198 | 0.20 / 214.09 | 2 | 2 |
2 | 7 | 2001.36 | 44 | 14.32 | 3002 | 1892 | 2.09 / 215.98 | 2 | 2 |
3 | 13 | 1473.52 | 18 | 14.54 | 2334 | 611 | 2.70 / 216.59 | 2 | 2 |
4 | 13 | 1058.08 | 18 | 14.66 | 1789 | 472 | 3.17 / 217.06 | 2 | 2 |
5 | 13 | 504.56 | 18 | 14.90 | 1048 | 281 | 3.45 / 217.34 | 2 | 2 |
6 | 13 | 25.64 | 18 | 15.12 | 365 | 99 | 3.55 / 217.44 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.10 | 311 | 775 | 4.33 / 218.22 | 2 | 2 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 27 | 15.06 | 494 | 201 | 0.20 / 209.75 | 2 | 2 |
2 | 7 | 2006.24 | 44 | 14.33 | 2987 | 1883 | 2.08 / 211.63 | 2 | 2 |
3 | 13 | 1590.24 | 18 | 14.50 | 2476 | 646 | 2.73 / 212.28 | 2 | 2 |
4 | 13 | 1039.16 | 18 | 14.67 | 1771 | 468 | 3.20 / 212.75 | 2 | 2 |
5 | 13 | 479.28 | 18 | 14.92 | 1016 | 273 | 3.47 / 213.02 | 2 | 2 |
6 | 13 | 21.04 | 18 | 15.14 | 349 | 95 | 3.57 / 213.12 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.11 | 311 | 775 | 4.34 / 213.89 | 2 | 2 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 27 | 15.07 | 487 | 198 | 0.20 / 205.44 | 2 | 2 |
2 | 7 | 2004.64 | 44 | 14.33 | 2975 | 1876 | 2.07 / 207.31 | 2 | 2 |
3 | 13 | 1459.36 | 18 | 14.54 | 2320 | 607 | 2.68 / 207.92 | 2 | 2 |
4 | 13 | 1058.08 | 18 | 14.68 | 1770 | 468 | 3.15 / 208.39 | 2 | 2 |
5 | 13 | 500.16 | 18 | 14.91 | 1052 | 282 | 3.43 / 208.67 | 2 | 2 |
6 | 13 | 49.64 | 18 | 15.12 | 401 | 109 | 3.54 / 208.78 | 2 | 2 |
7 | 8 | 0.64 | 165 | 15.11 | 309 | 770 | 4.31 / 209.55 | 2 | 2 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 27 | 15.06 | 509 | 207 | 0.21 / 201.09 | 2 | 2 |
2 | 7 | 2004.60 | 44 | 14.35 | 2993 | 1890 | 2.10 / 202.98 | 2 | 2 |
3 | 13 | 1594.32 | 18 | 14.50 | 2480 | 647 | 2.74 / 203.63 | 2 | 2 |
4 | 13 | 1045.04 | 18 | 14.68 | 1761 | 465 | 3.21 / 204.09 | 2 | 2 |
5 | 13 | 477.00 | 18 | 14.92 | 1014 | 272 | 3.48 / 204.36 | 2 | 2 |
6 | 13 | 39.04 | 18 | 15.13 | 377 | 103 | 3.58 / 204.47 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.11 | 310 | 773 | 4.36 / 205.24 | 2 | 2 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 27 | 15.07 | 493 | 201 | 0.20 / 196.70 | 2 | 2 |
2 | 7 | 2002.24 | 44 | 14.34 | 2985 | 1883 | 2.08 / 198.58 | 2 | 2 |
3 | 13 | 1580.36 | 18 | 14.52 | 2463 | 644 | 2.73 / 199.22 | 2 | 2 |
4 | 13 | 1040.52 | 18 | 14.69 | 1746 | 462 | 3.19 / 199.68 | 2 | 2 |
5 | 13 | 603.80 | 18 | 14.87 | 1182 | 316 | 3.51 / 200.00 | 2 | 2 |
6 | 13 | 35.16 | 18 | 15.13 | 375 | 102 | 3.61 / 200.10 | 2 | 2 |
7 | 8 | -0.08 | 165 | 15.11 | 312 | 778 | 4.39 / 200.88 | 2 | 2 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 27 | 15.06 | 502 | 204 | 0.20 / 192.43 | 2 | 2 |
2 | 7 | 2002.64 | 44 | 14.34 | 2998 | 1892 | 2.10 / 194.32 | 2 | 2 |
3 | 13 | 1463.60 | 18 | 14.56 | 2316 | 607 | 2.70 / 194.93 | 2 | 2 |
4 | 13 | 1062.28 | 18 | 14.68 | 1813 | 479 | 3.18 / 195.40 | 2 | 2 |
5 | 13 | 352.28 | 18 | 14.99 | 841 | 227 | 3.41 / 195.63 | 2 | 2 |
6 | 13 | 24.00 | 18 | 15.15 | 351 | 96 | 3.50 / 195.73 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.12 | 308 | 768 | 4.27 / 196.50 | 2 | 2 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 27 | 15.07 | 491 | 200 | 0.20 / 188.06 | 2 | 2 |
2 | 7 | 2006.40 | 44 | 14.33 | 3025 | 1907 | 2.11 / 189.97 | 2 | 2 |
3 | 13 | 1603.76 | 18 | 14.50 | 2519 | 657 | 2.76 / 190.63 | 2 | 2 |
4 | 13 | 1058.12 | 18 | 14.68 | 1800 | 476 | 3.24 / 191.10 | 2 | 2 |
5 | 13 | 373.24 | 18 | 14.98 | 878 | 237 | 3.48 / 191.34 | 2 | 2 |
6 | 13 | 51.96 | 18 | 15.13 | 401 | 109 | 3.59 / 191.45 | 2 | 2 |
7 | 8 | -0.16 | 165 | 15.11 | 310 | 773 | 4.36 / 192.22 | 2 | 2 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 27 | 15.07 | 501 | 204 | 0.20 / 183.79 | 2 | 2 |
2 | 7 | 2002.40 | 44 | 14.34 | 2994 | 1889 | 2.09 / 185.68 | 2 | 2 |
3 | 13 | 1586.48 | 18 | 14.52 | 2466 | 645 | 2.74 / 186.32 | 2 | 2 |
4 | 13 | 1161.80 | 18 | 14.63 | 1926 | 507 | 3.24 / 186.83 | 2 | 2 |
5 | 13 | 444.24 | 18 | 14.95 | 963 | 259 | 3.50 / 187.09 | 2 | 2 |
6 | 8 | 0.52 | 165 | 15.13 | 311 | 776 | 4.28 / 187.86 | 2 | 2 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 27 | 15.08 | 496 | 202 | 0.20 / 179.55 | 2 | 2 |
2 | 7 | 2008.48 | 44 | 14.34 | 3005 | 1896 | 2.10 / 181.44 | 2 | 2 |
3 | 13 | 1594.96 | 18 | 14.53 | 2449 | 641 | 2.74 / 182.08 | 2 | 2 |
4 | 13 | 1031.12 | 18 | 14.71 | 1736 | 460 | 3.20 / 182.54 | 2 | 2 |
5 | 13 | 462.08 | 18 | 14.95 | 994 | 267 | 3.47 / 182.81 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.13 | 310 | 774 | 4.24 / 183.58 | 2 | 2 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 27 | 15.07 | 515 | 210 | 0.21 / 175.28 | 2 | 2 |
2 | 7 | 2002.64 | 44 | 14.36 | 2964 | 1873 | 2.08 / 177.15 | 2 | 2 |
3 | 13 | 1581.88 | 18 | 14.53 | 2472 | 647 | 2.73 / 177.80 | 2 | 2 |
4 | 13 | 1155.08 | 18 | 14.64 | 1925 | 507 | 3.24 / 178.31 | 2 | 2 |
5 | 13 | 446.28 | 18 | 14.95 | 978 | 263 | 3.50 / 178.57 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.14 | 310 | 774 | 4.27 / 179.34 | 2 | 2 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 27 | 15.07 | 507 | 206 | 0.21 / 170.92 | 2 | 2 |
2 | 7 | 2001.72 | 44 | 14.36 | 2995 | 1892 | 2.10 / 172.82 | 2 | 2 |
3 | 13 | 1461.68 | 18 | 14.56 | 2316 | 607 | 2.71 / 173.42 | 2 | 2 |
4 | 13 | 1184.40 | 18 | 14.65 | 1921 | 507 | 3.21 / 173.93 | 2 | 2 |
5 | 13 | 467.20 | 18 | 14.95 | 1003 | 270 | 3.48 / 174.20 | 2 | 2 |
6 | 13 | 19.08 | 18 | 15.16 | 343 | 94 | 3.58 / 174.29 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.13 | 311 | 776 | 4.35 / 175.07 | 2 | 2 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 27 | 15.08 | 496 | 202 | 0.20 / 166.73 | 2 | 2 |
2 | 7 | 2003.40 | 44 | 14.36 | 2969 | 1876 | 2.08 / 168.61 | 2 | 2 |
3 | 13 | 1463.36 | 18 | 14.58 | 2275 | 597 | 2.67 / 169.21 | 2 | 2 |
4 | 13 | 1059.40 | 18 | 14.70 | 1766 | 467 | 3.14 / 169.67 | 2 | 2 |
5 | 13 | 490.92 | 18 | 14.94 | 1028 | 276 | 3.42 / 169.95 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.14 | 307 | 767 | 4.19 / 170.72 | 2 | 2 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 27 | 15.08 | 489 | 199 | 0.20 / 162.35 | 2 | 2 |
2 | 7 | 2001.16 | 44 | 14.37 | 2939 | 1858 | 2.06 / 164.21 | 2 | 2 |
3 | 13 | 1573.20 | 18 | 14.54 | 2460 | 644 | 2.70 / 164.85 | 2 | 2 |
4 | 13 | 1144.00 | 18 | 14.67 | 1886 | 498 | 3.20 / 165.35 | 2 | 2 |
5 | 13 | 429.96 | 18 | 14.98 | 934 | 252 | 3.45 / 165.60 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.14 | 307 | 767 | 4.22 / 166.37 | 2 | 2 |
7 | 14 | -0.04 | 35 | 15.12 | 313 | 166 | 4.38 / 166.53 | 2 | 2 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 27 | 15.09 | 487 | 198 | 0.20 / 158.16 | 2 | 2 |
2 | 7 | 2005.44 | 44 | 14.37 | 2970 | 1878 | 2.08 / 160.03 | 2 | 2 |
3 | 13 | 1595.92 | 18 | 14.54 | 2428 | 635 | 2.71 / 160.67 | 2 | 2 |
4 | 13 | 1030.80 | 18 | 14.73 | 1737 | 461 | 3.17 / 161.13 | 2 | 2 |
5 | 13 | 466.12 | 18 | 14.96 | 982 | 264 | 3.44 / 161.39 | 2 | 2 |
6 | 8 | 0.36 | 165 | 15.15 | 302 | 755 | 4.19 / 162.15 | 2 | 2 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 27 | 15.08 | 499 | 203 | 0.20 / 153.92 | 2 | 2 |
2 | 7 | 2003.12 | 44 | 14.37 | 2977 | 1882 | 2.09 / 155.80 | 2 | 2 |
3 | 13 | 1582.28 | 18 | 14.54 | 2475 | 648 | 2.73 / 156.45 | 2 | 2 |
4 | 13 | 1036.72 | 18 | 14.72 | 1760 | 466 | 3.20 / 156.91 | 2 | 2 |
5 | 13 | 475.72 | 18 | 14.96 | 1016 | 274 | 3.47 / 157.19 | 2 | 2 |
6 | 8 | -0.12 | 165 | 15.15 | 308 | 770 | 4.24 / 157.96 | 2 | 2 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 27 | 15.09 | 498 | 203 | 0.20 / 149.64 | 2 | 2 |
2 | 7 | 2001.76 | 44 | 14.37 | 2994 | 1893 | 2.10 / 151.53 | 2 | 2 |
3 | 13 | 1573.64 | 18 | 14.55 | 2443 | 640 | 2.74 / 152.17 | 2 | 2 |
4 | 13 | 1017.04 | 18 | 14.72 | 1735 | 460 | 3.20 / 152.63 | 2 | 2 |
5 | 13 | 344.72 | 18 | 15.02 | 826 | 223 | 3.42 / 152.85 | 2 | 2 |
6 | 13 | 21.12 | 18 | 15.18 | 340 | 93 | 3.51 / 152.94 | 2 | 2 |
7 | 8 | 0.28 | 165 | 15.15 | 308 | 770 | 4.28 / 153.71 | 2 | 2 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 27 | 15.09 | 496 | 202 | 0.20 / 145.35 | 2 | 2 |
2 | 7 | 2004.44 | 44 | 14.37 | 2976 | 1882 | 2.08 / 147.23 | 2 | 2 |
3 | 13 | 1468.64 | 18 | 14.58 | 2309 | 606 | 2.69 / 147.84 | 2 | 2 |
4 | 13 | 943.48 | 18 | 14.76 | 1637 | 435 | 3.12 / 148.27 | 2 | 2 |
5 | 13 | 527.36 | 18 | 14.93 | 1084 | 291 | 3.42 / 148.56 | 2 | 2 |
6 | 13 | 22.32 | 18 | 15.18 | 347 | 95 | 3.51 / 148.66 | 2 | 2 |
7 | 8 | 0.28 | 165 | 15.14 | 310 | 774 | 4.29 / 149.43 | 2 | 2 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 27 | 15.09 | 511 | 208 | 0.21 / 141.20 | 2 | 2 |
2 | 7 | 2004.12 | 44 | 14.38 | 2979 | 1885 | 2.09 / 143.08 | 2 | 2 |
3 | 13 | 1459.40 | 18 | 14.59 | 2307 | 606 | 2.70 / 143.69 | 2 | 2 |
4 | 13 | 1047.92 | 18 | 14.72 | 1757 | 466 | 3.16 / 144.15 | 2 | 2 |
5 | 13 | 340.16 | 18 | 15.03 | 811 | 219 | 3.38 / 144.37 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.15 | 310 | 775 | 4.16 / 145.15 | 2 | 2 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 27 | 15.10 | 495 | 202 | 0.20 / 136.81 | 2 | 2 |
2 | 7 | 2004.04 | 44 | 14.37 | 3001 | 1897 | 2.10 / 138.71 | 2 | 2 |
3 | 13 | 1593.16 | 18 | 14.55 | 2475 | 648 | 2.75 / 139.36 | 2 | 2 |
4 | 13 | 1167.20 | 18 | 14.70 | 1861 | 492 | 3.24 / 139.85 | 2 | 2 |
5 | 13 | 729.76 | 18 | 14.84 | 1361 | 364 | 3.60 / 140.21 | 2 | 2 |
6 | 8 | -0.12 | 165 | 15.15 | 310 | 775 | 4.38 / 140.99 | 2 | 2 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 27 | 15.10 | 491 | 200 | 0.20 / 132.61 | 2 | 2 |
2 | 7 | 2002.76 | 44 | 14.38 | 2981 | 1886 | 2.09 / 134.50 | 2 | 2 |
3 | 13 | 1454.44 | 18 | 14.60 | 2282 | 600 | 2.69 / 135.10 | 2 | 2 |
4 | 13 | 1049.04 | 18 | 14.72 | 1758 | 466 | 3.15 / 135.56 | 2 | 2 |
5 | 13 | 482.20 | 18 | 14.97 | 1012 | 273 | 3.42 / 135.83 | 2 | 2 |
6 | 8 | 0.64 | 165 | 15.16 | 310 | 775 | 4.20 / 136.61 | 2 | 2 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 27 | 15.10 | 509 | 208 | 0.21 / 128.37 | 2 | 2 |
2 | 7 | 2004.44 | 44 | 14.39 | 2991 | 1894 | 2.10 / 130.26 | 2 | 2 |
3 | 13 | 1584.08 | 18 | 14.56 | 2483 | 651 | 2.75 / 130.91 | 2 | 2 |
4 | 13 | 1027.44 | 18 | 14.74 | 1725 | 458 | 3.21 / 131.37 | 2 | 2 |
5 | 13 | 465.04 | 18 | 14.98 | 984 | 265 | 3.48 / 131.63 | 2 | 2 |
6 | 8 | -0.12 | 165 | 15.16 | 310 | 775 | 4.25 / 132.41 | 2 | 2 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 27 | 15.11 | 492 | 201 | 0.20 / 124.06 | 2 | 2 |
2 | 7 | 2001.56 | 44 | 14.40 | 2963 | 1877 | 2.08 / 125.93 | 2 | 2 |
3 | 13 | 1579.28 | 18 | 14.58 | 2435 | 639 | 2.72 / 126.57 | 2 | 2 |
4 | 13 | 1028.88 | 18 | 14.75 | 1728 | 459 | 3.18 / 127.03 | 2 | 2 |
5 | 13 | 465.92 | 18 | 14.98 | 996 | 269 | 3.44 / 127.30 | 2 | 2 |
6 | 13 | 19.12 | 18 | 15.19 | 332 | 91 | 3.54 / 127.39 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.16 | 307 | 768 | 4.30 / 128.16 | 2 | 2 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 27 | 15.11 | 509 | 208 | 0.21 / 119.85 | 2 | 2 |
2 | 7 | 2004.92 | 44 | 14.40 | 2979 | 1887 | 2.10 / 121.73 | 2 | 2 |
3 | 13 | 1602.16 | 18 | 14.56 | 2499 | 655 | 2.75 / 122.39 | 2 | 2 |
4 | 13 | 1040.68 | 18 | 14.74 | 1757 | 466 | 3.22 / 122.85 | 2 | 2 |
5 | 13 | 339.20 | 18 | 15.05 | 824 | 223 | 3.44 / 123.08 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.17 | 311 | 778 | 4.22 / 123.86 | 2 | 2 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 27 | 15.11 | 513 | 209 | 0.21 / 115.59 | 2 | 2 |
2 | 7 | 2002.84 | 44 | 14.40 | 2980 | 1888 | 2.10 / 117.48 | 2 | 2 |
3 | 13 | 1723.76 | 18 | 14.54 | 2627 | 688 | 2.78 / 118.16 | 2 | 2 |
4 | 13 | 1006.16 | 18 | 14.77 | 1683 | 447 | 3.23 / 118.61 | 2 | 2 |
5 | 13 | 438.56 | 18 | 15.00 | 955 | 258 | 3.49 / 118.87 | 2 | 2 |
6 | 8 | -0.12 | 165 | 15.17 | 307 | 768 | 4.26 / 119.64 | 2 | 2 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 27 | 15.12 | 504 | 206 | 0.21 / 111.16 | 2 | 2 |
2 | 7 | 2003.52 | 44 | 14.40 | 2991 | 1895 | 2.10 / 113.05 | 2 | 2 |
3 | 13 | 1599.28 | 18 | 14.57 | 2497 | 655 | 2.76 / 113.71 | 2 | 2 |
4 | 13 | 1041.44 | 18 | 14.75 | 1749 | 464 | 3.22 / 114.17 | 2 | 2 |
5 | 13 | 611.96 | 18 | 14.92 | 1186 | 319 | 3.54 / 114.49 | 2 | 2 |
6 | 13 | 64.48 | 18 | 15.17 | 416 | 114 | 3.65 / 114.60 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.16 | 311 | 778 | 4.43 / 115.38 | 2 | 2 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 26 | 15.12 | 497 | 195 | 0.20 / 106.90 | 2 | 2 |
2 | 7 | 2003.24 | 44 | 14.40 | 2982 | 1889 | 2.08 / 108.79 | 2 | 2 |
3 | 13 | 1588.64 | 18 | 14.57 | 2490 | 653 | 2.74 / 109.45 | 2 | 2 |
4 | 13 | 1040.76 | 18 | 14.75 | 1761 | 468 | 3.21 / 109.91 | 2 | 2 |
5 | 13 | 477.20 | 18 | 14.99 | 1008 | 272 | 3.48 / 110.19 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.18 | 305 | 764 | 4.24 / 110.95 | 2 | 2 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 26 | 15.12 | 500 | 197 | 0.20 / 102.62 | 2 | 2 |
2 | 7 | 2005.04 | 44 | 14.42 | 2955 | 1875 | 2.07 / 104.50 | 2 | 2 |
3 | 13 | 1574.32 | 18 | 14.61 | 2404 | 632 | 2.70 / 105.13 | 2 | 2 |
4 | 13 | 1001.96 | 18 | 14.77 | 1706 | 454 | 3.16 / 105.59 | 2 | 2 |
5 | 13 | 441.00 | 18 | 15.01 | 967 | 261 | 3.42 / 105.85 | 2 | 2 |
6 | 13 | 29.96 | 18 | 15.20 | 359 | 98 | 3.52 / 105.95 | 2 | 2 |
7 | 8 | -0.32 | 165 | 15.17 | 305 | 763 | 4.28 / 106.71 | 2 | 2 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 26 | 15.12 | 492 | 193 | 0.19 / 98.29 | 2 | 2 |
2 | 7 | 2001.44 | 44 | 14.43 | 2947 | 1871 | 2.06 / 100.17 | 2 | 2 |
3 | 13 | 1580.36 | 18 | 14.61 | 2420 | 636 | 2.70 / 100.80 | 2 | 2 |
4 | 13 | 1023.88 | 18 | 14.76 | 1754 | 466 | 3.17 / 101.27 | 2 | 2 |
5 | 13 | 470.48 | 18 | 15.00 | 997 | 269 | 3.44 / 101.54 | 2 | 2 |
6 | 13 | 75.92 | 18 | 15.17 | 448 | 122 | 3.56 / 101.66 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.18 | 307 | 769 | 4.33 / 102.43 | 2 | 2 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 26 | 15.13 | 506 | 199 | 0.20 / 93.84 | 2 | 2 |
2 | 7 | 2001.64 | 44 | 14.42 | 2992 | 1898 | 2.10 / 95.74 | 2 | 2 |
3 | 13 | 1715.08 | 18 | 14.55 | 2654 | 695 | 2.79 / 96.44 | 2 | 2 |
4 | 13 | 1123.20 | 18 | 14.72 | 1855 | 492 | 3.28 / 96.93 | 2 | 2 |
5 | 13 | 558.52 | 18 | 14.96 | 1120 | 302 | 3.59 / 97.23 | 2 | 2 |
6 | 13 | 51.92 | 18 | 15.19 | 400 | 109 | 3.69 / 97.34 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.18 | 304 | 761 | 4.46 / 98.10 | 2 | 2 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 26 | 15.15 | 462 | 182 | 0.18 / 89.57 | 2 | 2 |
2 | 7 | 2004.04 | 44 | 14.44 | 2972 | 1888 | 2.07 / 91.46 | 2 | 2 |
3 | 13 | 1571.92 | 18 | 14.61 | 2427 | 638 | 2.71 / 92.09 | 2 | 2 |
4 | 13 | 1012.68 | 18 | 14.78 | 1698 | 452 | 3.16 / 92.55 | 2 | 2 |
5 | 13 | 449.24 | 18 | 15.02 | 950 | 257 | 3.42 / 92.80 | 2 | 2 |
6 | 13 | 35.28 | 18 | 15.21 | 358 | 98 | 3.52 / 92.90 | 2 | 2 |
7 | 8 | 0.36 | 165 | 15.19 | 297 | 744 | 4.26 / 93.64 | 2 | 2 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 26 | 15.14 | 479 | 189 | 0.19 / 85.35 | 2 | 2 |
2 | 7 | 2003.16 | 44 | 14.44 | 2966 | 1884 | 2.07 / 87.23 | 2 | 2 |
3 | 13 | 1582.60 | 18 | 14.61 | 2425 | 638 | 2.71 / 87.87 | 2 | 2 |
4 | 13 | 1010.76 | 18 | 14.79 | 1696 | 452 | 3.16 / 88.32 | 2 | 2 |
5 | 13 | 443.64 | 18 | 15.03 | 952 | 258 | 3.42 / 88.58 | 2 | 2 |
6 | 13 | 17.48 | 18 | 15.23 | 325 | 89 | 3.51 / 88.67 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.20 | 285 | 715 | 4.22 / 89.39 | 2 | 2 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 26 | 15.15 | 466 | 184 | 0.18 / 81.11 | 2 | 2 |
2 | 7 | 2002.56 | 44 | 14.45 | 2969 | 1888 | 2.07 / 83.00 | 2 | 2 |
3 | 13 | 1568.76 | 18 | 14.63 | 2410 | 635 | 2.71 / 83.63 | 2 | 2 |
4 | 13 | 1014.80 | 18 | 14.79 | 1713 | 456 | 3.16 / 84.09 | 2 | 2 |
5 | 13 | 441.96 | 18 | 15.03 | 949 | 257 | 3.42 / 84.35 | 2 | 2 |
6 | 13 | 32.84 | 18 | 15.22 | 353 | 97 | 3.52 / 84.44 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.20 | 286 | 717 | 4.23 / 85.16 | 2 | 2 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 26 | 15.15 | 460 | 181 | 0.18 / 76.91 | 2 | 2 |
2 | 7 | 2006.80 | 44 | 14.46 | 2957 | 1881 | 2.06 / 78.79 | 2 | 2 |
3 | 13 | 1460.84 | 18 | 14.65 | 2294 | 605 | 2.67 / 79.39 | 2 | 2 |
4 | 13 | 1052.92 | 18 | 14.78 | 1759 | 468 | 3.14 / 79.86 | 2 | 2 |
5 | 13 | 350.04 | 18 | 15.08 | 820 | 223 | 3.36 / 80.08 | 2 | 2 |
6 | 13 | 99.28 | 18 | 15.18 | 463 | 127 | 3.48 / 80.21 | 2 | 2 |
7 | 8 | -0.16 | 165 | 15.20 | 286 | 717 | 4.20 / 80.93 | 2 | 2 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 26 | 15.17 | 483 | 191 | 0.19 / 72.43 | 2 | 2 |
2 | 7 | 2003.00 | 44 | 14.46 | 2950 | 1877 | 2.07 / 74.30 | 2 | 2 |
3 | 13 | 1584.48 | 18 | 14.63 | 2454 | 646 | 2.71 / 74.95 | 2 | 2 |
4 | 13 | 907.28 | 18 | 14.84 | 1577 | 421 | 3.13 / 75.37 | 2 | 2 |
5 | 13 | 359.88 | 18 | 15.08 | 825 | 224 | 3.36 / 75.59 | 2 | 2 |
6 | 13 | 45.84 | 18 | 15.22 | 369 | 101 | 3.46 / 75.69 | 2 | 2 |
7 | 8 | 0.24 | 165 | 15.21 | 283 | 710 | 4.17 / 76.40 | 2 | 2 |
8 | 14 | 0.24 | 75 | 15.18 | 283 | 322 | 4.49 / 76.73 | 2 | 2 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 26 | 15.17 | 483 | 191 | 0.19 / 68.06 | 2 | 2 |
2 | 7 | 2005.60 | 44 | 14.47 | 2965 | 1888 | 2.08 / 69.95 | 2 | 2 |
3 | 13 | 1593.20 | 18 | 14.61 | 2499 | 657 | 2.74 / 70.61 | 2 | 2 |
4 | 13 | 1170.76 | 18 | 14.75 | 1890 | 502 | 3.24 / 71.11 | 2 | 2 |
5 | 13 | 582.56 | 18 | 14.98 | 1135 | 306 | 3.54 / 71.42 | 2 | 2 |
6 | 13 | 34.24 | 18 | 15.23 | 352 | 96 | 3.64 / 71.51 | 2 | 2 |
7 | 8 | -0.24 | 165 | 15.21 | 287 | 720 | 4.36 / 72.23 | 2 | 2 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 26 | 15.17 | 455 | 179 | 0.18 / 63.88 | 2 | 2 |
2 | 7 | 2002.76 | 44 | 14.47 | 2966 | 1888 | 2.07 / 65.77 | 2 | 2 |
3 | 13 | 1457.76 | 18 | 14.66 | 2307 | 609 | 2.68 / 66.38 | 2 | 2 |
4 | 13 | 1039.64 | 18 | 14.79 | 1752 | 466 | 3.14 / 66.84 | 2 | 2 |
5 | 13 | 338.04 | 18 | 15.09 | 811 | 220 | 3.36 / 67.07 | 2 | 2 |
6 | 13 | 24.68 | 18 | 15.24 | 334 | 92 | 3.45 / 67.16 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.21 | 286 | 718 | 4.17 / 67.87 | 2 | 2 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 26 | 15.18 | 472 | 186 | 0.19 / 59.55 | 2 | 2 |
2 | 7 | 2000.52 | 44 | 14.47 | 2967 | 1889 | 2.08 / 61.44 | 2 | 2 |
3 | 13 | 1714.96 | 18 | 14.61 | 2607 | 686 | 2.76 / 62.13 | 2 | 2 |
4 | 13 | 1139.92 | 18 | 14.76 | 1855 | 493 | 3.25 / 62.62 | 2 | 2 |
5 | 13 | 415.52 | 18 | 15.06 | 910 | 247 | 3.50 / 62.87 | 2 | 2 |
6 | 13 | 56.56 | 18 | 15.22 | 402 | 110 | 3.61 / 62.98 | 2 | 2 |
7 | 8 | 0.32 | 165 | 15.22 | 289 | 726 | 4.34 / 63.70 | 2 | 2 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 26 | 15.17 | 488 | 192 | 0.19 / 55.31 | 2 | 2 |
2 | 7 | 2008.72 | 44 | 14.48 | 2979 | 1898 | 2.09 / 57.21 | 2 | 2 |
3 | 13 | 1584.92 | 18 | 14.63 | 2468 | 650 | 2.74 / 57.86 | 2 | 2 |
4 | 13 | 1022.92 | 18 | 14.80 | 1736 | 462 | 3.20 / 58.32 | 2 | 2 |
5 | 13 | 325.12 | 18 | 15.11 | 782 | 213 | 3.42 / 58.53 | 2 | 2 |
6 | 13 | 37.76 | 18 | 15.23 | 363 | 100 | 3.52 / 58.63 | 2 | 2 |
7 | 8 | 0.32 | 165 | 15.22 | 292 | 733 | 4.25 / 59.37 | 2 | 2 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 26 | 15.18 | 484 | 191 | 0.19 / 51.00 | 2 | 2 |
2 | 7 | 2002.76 | 44 | 14.49 | 2948 | 1880 | 2.07 / 52.88 | 2 | 2 |
3 | 13 | 1582.40 | 18 | 14.64 | 2478 | 653 | 2.72 / 53.53 | 2 | 2 |
4 | 13 | 1138.52 | 18 | 14.77 | 1862 | 495 | 3.22 / 54.03 | 2 | 2 |
5 | 13 | 421.16 | 18 | 15.06 | 924 | 250 | 3.47 / 54.28 | 2 | 2 |
6 | 13 | 55.60 | 18 | 15.22 | 399 | 109 | 3.58 / 54.39 | 2 | 2 |
7 | 8 | -0.16 | 165 | 15.22 | 291 | 731 | 4.31 / 55.12 | 2 | 2 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 26 | 15.18 | 470 | 185 | 0.19 / 46.79 | 2 | 2 |
2 | 7 | 2001.08 | 44 | 14.49 | 2976 | 1897 | 2.08 / 48.68 | 2 | 2 |
3 | 13 | 1578.84 | 18 | 14.66 | 2417 | 638 | 2.72 / 49.32 | 2 | 2 |
4 | 13 | 1011.72 | 18 | 14.82 | 1693 | 452 | 3.17 / 49.77 | 2 | 2 |
5 | 13 | 316.76 | 18 | 15.12 | 781 | 213 | 3.38 / 49.99 | 2 | 2 |
6 | 13 | 18.28 | 18 | 15.25 | 326 | 89 | 3.47 / 50.07 | 2 | 2 |
7 | 8 | 0.32 | 165 | 15.22 | 292 | 733 | 4.21 / 50.81 | 2 | 2 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 26 | 15.17 | 481 | 190 | 0.19 / 42.66 | 2 | 2 |
2 | 7 | 2009.36 | 44 | 14.49 | 2980 | 1900 | 2.09 / 44.56 | 2 | 2 |
3 | 13 | 1580.08 | 18 | 14.65 | 2438 | 643 | 2.73 / 45.21 | 2 | 2 |
4 | 13 | 1019.36 | 18 | 14.82 | 1705 | 455 | 3.19 / 45.66 | 2 | 2 |
5 | 13 | 323.88 | 18 | 15.11 | 787 | 214 | 3.40 / 45.88 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.23 | 288 | 724 | 4.13 / 46.60 | 2 | 2 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 26 | 15.17 | 489 | 193 | 0.19 / 38.41 | 2 | 2 |
2 | 7 | 2003.12 | 44 | 14.51 | 2930 | 1871 | 2.06 / 40.28 | 2 | 2 |
3 | 13 | 1581.64 | 18 | 14.66 | 2473 | 653 | 2.72 / 40.93 | 2 | 2 |
4 | 13 | 1016.56 | 18 | 14.82 | 1700 | 453 | 3.17 / 41.38 | 2 | 2 |
5 | 13 | 457.52 | 18 | 15.06 | 970 | 263 | 3.43 / 41.65 | 2 | 2 |
6 | 13 | 31.72 | 18 | 15.24 | 358 | 98 | 3.53 / 41.74 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.22 | 291 | 731 | 4.26 / 42.48 | 2 | 2 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 26 | 15.18 | 458 | 181 | 0.18 / 34.13 | 2 | 2 |
2 | 7 | 2002.88 | 45 | 14.50 | 2992 | 1952 | 2.13 / 36.08 | 2 | 2 |
3 | 13 | 1464.16 | 18 | 14.70 | 2311 | 611 | 2.74 / 36.69 | 2 | 2 |
4 | 13 | 1050.92 | 18 | 14.81 | 1754 | 468 | 3.21 / 37.16 | 2 | 2 |
5 | 13 | 322.64 | 18 | 15.11 | 790 | 215 | 3.43 / 37.37 | 2 | 2 |
6 | 13 | 39.96 | 18 | 15.24 | 373 | 102 | 3.53 / 37.48 | 2 | 2 |
7 | 8 | -0.24 | 165 | 15.22 | 294 | 738 | 4.27 / 38.21 | 2 | 2 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 27 | 15.18 | 467 | 191 | 0.19 / 30.00 | 2 | 2 |
2 | 7 | 2003.32 | 44 | 14.50 | 2987 | 1906 | 2.10 / 31.91 | 2 | 2 |
3 | 13 | 1585.40 | 18 | 14.66 | 2465 | 650 | 2.75 / 32.56 | 2 | 2 |
4 | 13 | 1013.28 | 18 | 14.83 | 1689 | 451 | 3.20 / 33.01 | 2 | 2 |
5 | 13 | 304.88 | 18 | 15.13 | 759 | 207 | 3.41 / 33.22 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.24 | 290 | 729 | 4.13 / 33.95 | 2 | 2 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 26 | 15.17 | 493 | 194 | 0.19 / 25.93 | 2 | 2 |
2 | 7 | 2009.64 | 44 | 14.51 | 2958 | 1889 | 2.08 / 27.81 | 2 | 2 |
3 | 13 | 1455.64 | 18 | 14.71 | 2270 | 601 | 2.68 / 28.42 | 2 | 2 |
4 | 13 | 1040.32 | 18 | 14.83 | 1729 | 462 | 3.15 / 28.88 | 2 | 2 |
5 | 13 | 319.40 | 18 | 15.13 | 772 | 210 | 3.36 / 29.09 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.24 | 288 | 724 | 4.08 / 29.81 | 2 | 2 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 25 | 15.18 | 478 | 181 | 0.18 / 21.63 | 2 | 2 |
2 | 3 | 1046.52 | 1 | 15.16 | 1903 | 29 | 0.21 / 21.66 | 2 | 2 |
3 | 7 | 2003.92 | 44 | 14.52 | 2973 | 1899 | 2.11 / 23.56 | 2 | 2 |
4 | 13 | 1576.16 | 20 | 14.66 | 2485 | 729 | 2.84 / 24.29 | 2 | 2 |
5 | 13 | 999.64 | 20 | 14.83 | 1681 | 499 | 3.34 / 24.79 | 2 | 2 |
6 | 13 | 282.00 | 20 | 15.13 | 727 | 220 | 3.56 / 25.01 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.24 | 288 | 724 | 4.28 / 25.73 | 2 | 2 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 23 | 15.20 | 472 | 165 | 0.17 / 17.36 | 2 | 2 |
2 | 3 | 1080.64 | 2 | 15.07 | 1943 | 59 | 0.22 / 17.42 | 2 | 2 |
3 | 7 | 2001.68 | 44 | 14.53 | 2971 | 1899 | 2.12 / 19.32 | 2 | 2 |
4 | 13 | 1586.28 | 20 | 14.66 | 2486 | 729 | 2.85 / 20.05 | 2 | 2 |
5 | 13 | 1008.56 | 20 | 14.83 | 1705 | 506 | 3.36 / 20.55 | 2 | 2 |
6 | 13 | 150.36 | 20 | 15.20 | 537 | 163 | 3.52 / 20.72 | 2 | 2 |
7 | 8 | 0.28 | 165 | 15.24 | 292 | 734 | 4.26 / 21.45 | 2 | 2 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 25 | 15.18 | 506 | 192 | 0.19 / 13.42 | 2 | 2 |
2 | 7 | 1513.88 | 44 | 14.75 | 2373 | 1540 | 1.73 / 14.96 | 2 | 2 |
3 | 13 | 1262.56 | 20 | 14.83 | 2049 | 608 | 2.34 / 15.57 | 2 | 2 |
4 | 13 | 709.28 | 20 | 15.00 | 1330 | 399 | 2.74 / 15.97 | 2 | 2 |
5 | 13 | 131.72 | 20 | 15.23 | 518 | 158 | 2.90 / 16.13 | 2 | 2 |
6 | 8 | 0.00 | 240 | 15.25 | 292 | 1069 | 3.97 / 17.20 | 2 | 2 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 25 | 15.16 | 513 | 194 | 0.19 / 9.43 | 2 | 2 |
2 | 7 | 1518.32 | 44 | 14.75 | 2378 | 1543 | 1.74 / 10.97 | 2 | 2 |
3 | 13 | 1270.68 | 20 | 14.82 | 2047 | 607 | 2.34 / 11.58 | 2 | 2 |
4 | 13 | 708.96 | 20 | 14.99 | 1321 | 396 | 2.74 / 11.97 | 2 | 2 |
5 | 13 | 119.36 | 20 | 15.23 | 503 | 153 | 2.89 / 12.13 | 2 | 2 |
6 | 8 | 0.80 | 240 | 15.23 | 302 | 1104 | 4.00 / 13.23 | 2 | 2 |
Average= | 3.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 24 | 15.19 | 511 | 186 | 0.19 / 5.24 | 2 | 2 |
2 | 3 | 1028.28 | 1 | 15.22 | 1925 | 29 | 0.22 / 5.26 | 2 | 2 |
3 | 7 | 1512.56 | 75 | 14.67 | 2343 | 2578 | 2.79 / 7.84 | 2 | 2 |
4 | 13 | 288.92 | 25 | 15.14 | 738 | 279 | 3.07 / 8.12 | 2 | 2 |
5 | 8 | 0.04 | 240 | 15.22 | 304 | 1110 | 4.18 / 9.23 | 2 | 2 |
Average= | 3.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 25 | 15.33 | 499 | 191 | 0.19 / 2.04 | 2 | 2 |
2 | 3 | 957.48 | -1 | 15.58 | 0 | 0 | 0.00 / 2.04 | 2 | 2 |
3 | 7 | 990.72 | 75 | 14.90 | 1671 | 1867 | 2.06 / 3.91 | 2 | 2 |
4 | 8 | 0.04 | 240 | 15.26 | 311 | 1139 | 3.20 / 5.05 | 2 | 2 |
Average= | 2.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 82.48 | 25 | 15.51 | 467 | 181 | 0.18 / 0.18 | 2 | 2 |
2 | 7 | 91.36 | 74 | 15.46 | 473 | 541 | 0.72 / 0.72 | 2 | 2 |
3 | 8 | 0.24 | 240 | 15.43 | 305 | 1129 | 1.85 / 1.85 | 2 | 2 |
Average= | 1.85 (KJ/cycle) |