SIO Argo Site:
Pump Diagnostics Page   



Serial= 8557 WMO= 5905239

Return

←PreviousNext→

Bug in float firmware: Transmitted values shaded red are not valid


Cycle 246 GMT 13/ 4/2024 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 28 15.07 0 0 0.00 / 1052.84 2 2
2 7 2007.72 42 14.12 3085 1830 1.83 / 1054.67 2 2
3 13 1881.64 19 14.11 2941 788 2.62 / 1055.46 2 2
4 13 1121.12 19 14.41 1938 531 3.15 / 1055.99 2 5
5 13 540.20 19 14.67 1151 321 3.47 / 1056.31 2 3
6 13 69.44 19 14.97 414 118 3.59 / 1056.43 2 2
7 13 18.00 19 14.99 333 95 3.68 / 1056.53 2 2
8 8 0.12 175 14.95 308 806 4.49 / 1057.33 2 2
Average= 4.28
(KJ/cycle)

Cycle 245 GMT 3/ 4/2024 20:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 28 15.07 0 0 0.00 / 1048.50 2 2
2 7 2010.16 42 14.12 3077 1825 1.82 / 1050.32 2 2
3 13 1751.76 19 14.16 2783 749 2.57 / 1051.07 2 3
4 13 1172.52 19 14.38 1991 544 3.12 / 1051.61 2 2
5 13 459.84 19 14.72 1034 289 3.41 / 1051.90 2 5
6 13 93.04 19 14.95 448 127 3.53 / 1052.03 2 2
7 8 0.08 175 14.95 311 814 4.35 / 1052.84 2 2
Average= 4.28
(KJ/cycle)

Cycle 244 GMT 24/ 3/2024 20:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 28 15.04 0 0 0.00 / 1044.08 2 2
2 7 2004.44 42 14.12 3080 1827 1.83 / 1045.91 2 2
3 13 1733.16 19 14.17 2730 735 2.56 / 1046.64 2 2
4 13 1299.96 19 14.32 2151 585 3.15 / 1047.23 2 3
5 13 573.44 19 14.66 1192 332 3.48 / 1047.56 2 4
6 13 74.16 19 14.96 427 121 3.60 / 1047.68 2 2
7 8 0.12 175 14.95 311 814 4.41 / 1048.50 2 2
Average= 4.28
(KJ/cycle)

Cycle 243 GMT 14/ 3/2024 21:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 28 15.04 0 0 0.00 / 1039.71 2 2
2 7 2002.16 42 14.12 3074 1823 1.82 / 1041.54 2 2
3 13 1725.20 19 14.17 2748 740 2.56 / 1042.28 2 2
4 13 1141.32 19 14.39 1960 536 3.10 / 1042.81 2 4
5 13 557.84 19 14.66 1170 326 3.42 / 1043.14 2 5
6 13 69.56 19 14.96 419 119 3.54 / 1043.26 2 2
7 8 0.08 175 14.94 315 824 4.37 / 1044.08 2 2
Average= 4.28
(KJ/cycle)

Cycle 242 GMT 4/ 3/2024 21:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 28 15.05 0 0 0.00 / 1035.30 2 2
2 7 2006.04 42 14.12 3083 1828 1.83 / 1037.12 2 2
3 13 1729.88 19 14.16 2755 741 2.57 / 1037.86 2 2
4 13 1142.92 19 14.39 1965 537 3.11 / 1038.40 2 3
5 13 560.36 19 14.66 1181 329 3.44 / 1038.73 2 4
6 13 134.92 19 14.92 530 150 3.59 / 1038.88 2 2
7 8 0.12 175 14.93 319 833 4.42 / 1039.71 2 2
Average= 4.28
(KJ/cycle)

Cycle 241 GMT 23/ 2/2024 22:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 28 15.05 0 0 0.00 / 1030.92 2 2
2 7 2008.24 42 14.12 3097 1837 1.84 / 1032.76 2 2
3 13 1750.44 19 14.15 2782 748 2.58 / 1033.50 2 2
4 13 1186.72 19 14.37 2015 550 3.13 / 1034.05 2 3
5 13 477.60 19 14.70 1068 298 3.43 / 1034.35 2 4
6 13 95.16 19 14.94 458 130 3.56 / 1034.48 2 2
7 8 0.12 175 14.94 311 813 4.38 / 1035.30 2 2
Average= 4.28
(KJ/cycle)

Cycle 240 GMT 13/ 2/2024 22:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 28 15.05 0 0 0.00 / 1026.51 2 2
2 7 2005.80 42 14.12 3089 1832 1.83 / 1028.34 2 2
3 13 1736.32 19 14.16 2752 740 2.57 / 1029.08 2 2
4 13 1150.60 19 14.39 1952 534 3.11 / 1029.61 2 2
5 13 569.76 19 14.65 1195 333 3.44 / 1029.95 2 2
6 13 138.56 19 14.91 521 148 3.59 / 1030.09 2 2
7 8 0.08 175 14.94 316 826 4.41 / 1030.92 2 2
Average= 4.28
(KJ/cycle)

Cycle 239 GMT 3/ 2/2024 23: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 28 15.05 0 0 0.00 / 1022.20 2 2
2 7 2004.40 42 14.13 3064 1818 1.82 / 1024.02 2 2
3 13 1587.56 19 14.22 2541 687 2.50 / 1024.70 2 2
4 13 1040.92 19 14.43 1828 501 3.01 / 1025.21 2 3
5 13 591.04 19 14.63 1220 339 3.35 / 1025.55 2 2
6 13 135.12 19 14.91 517 146 3.49 / 1025.69 2 2
7 8 0.08 175 14.93 312 815 4.31 / 1026.51 2 2
Average= 4.28
(KJ/cycle)

Cycle 238 GMT 24/ 1/2024 23:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 28 15.05 0 0 0.00 / 1017.80 2 2
2 7 2003.12 42 14.12 3095 1835 1.84 / 1019.63 2 2
3 13 1725.88 19 14.16 2749 740 2.58 / 1020.37 2 3
4 13 1159.48 19 14.38 1980 541 3.12 / 1020.91 2 4
5 13 574.00 19 14.64 1196 333 3.45 / 1021.24 2 4
6 13 67.32 19 14.95 421 120 3.57 / 1021.36 2 2
7 8 -0.04 175 14.93 320 836 4.40 / 1022.20 2 2
Average= 4.28
(KJ/cycle)

Cycle 237 GMT 14/ 1/2024 23:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 28 15.05 0 0 0.00 / 1013.47 2 2
2 7 2006.04 42 14.13 3068 1821 1.82 / 1015.29 2 2
3 13 1741.80 19 14.16 2766 744 2.56 / 1016.03 2 2
4 13 1033.36 19 14.43 1816 498 3.06 / 1016.53 2 3
5 13 481.48 19 14.69 1083 302 3.37 / 1016.83 2 2
6 13 103.76 19 14.92 472 134 3.50 / 1016.97 2 2
7 8 0.04 175 14.92 318 830 4.33 / 1017.80 2 2
Average= 4.28
(KJ/cycle)

Cycle 236 GMT 5/ 1/2024 0:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 28 15.04 0 0 0.00 / 1009.02 2 2
2 7 2003.76 42 14.12 3091 1833 1.83 / 1010.85 2 2
3 13 1725.52 19 14.17 2711 730 2.56 / 1011.58 2 2
4 13 1294.96 19 14.32 2136 581 3.14 / 1012.17 2 3
5 13 573.00 19 14.64 1190 331 3.48 / 1012.50 2 3
6 13 133.72 19 14.90 519 147 3.62 / 1012.64 2 2
7 8 0.12 175 14.93 315 823 4.45 / 1013.47 2 2
Average= 4.28
(KJ/cycle)

Cycle 235 GMT 26/12/2023 0:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 28 15.04 0 0 0.00 / 1004.53 2 2
2 7 2006.28 42 14.12 3073 1822 1.82 / 1006.36 2 2
3 13 1876.68 19 14.11 2956 792 2.61 / 1007.15 2 2
4 13 1161.92 19 14.38 1984 542 3.16 / 1007.69 2 5
5 13 608.80 19 14.63 1245 346 3.50 / 1008.04 2 2
6 13 168.64 19 14.88 580 164 3.67 / 1008.20 2 2
7 8 0.08 175 14.92 314 820 4.49 / 1009.02 2 2
Average= 4.28
(KJ/cycle)

Cycle 234 GMT 16/12/2023 0:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 28 15.05 0 0 0.00 / 1000.25 2 2
2 7 2011.24 42 14.12 3087 1831 1.83 / 1002.08 2 2
3 13 1614.60 19 14.21 2569 694 2.52 / 1002.77 2 2
4 13 1054.24 19 14.41 1859 509 3.03 / 1003.28 2 3
5 13 486.76 19 14.69 1081 302 3.34 / 1003.58 2 3
6 13 101.28 19 14.93 461 131 3.47 / 1003.71 2 2
7 8 0.04 175 14.93 314 820 4.29 / 1004.53 2 2
Average= 4.27
(KJ/cycle)

Cycle 233 GMT 6/12/2023 1:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 28 15.05 0 0 0.00 / 995.96 2 2
2 7 2003.08 42 14.12 3093 1834 1.83 / 997.79 2 2
3 13 1595.36 19 14.22 2554 690 2.52 / 998.48 2 4
4 13 1169.16 19 14.37 1988 543 3.07 / 999.03 2 3
5 13 453.28 19 14.70 1031 288 3.36 / 999.31 2 3
6 13 93.84 19 14.94 447 127 3.48 / 999.44 2 2
7 8 0.04 175 14.93 309 807 4.29 / 1000.25 2 2
Average= 4.27
(KJ/cycle)

Cycle 232 GMT 26/11/2023 2: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 28 15.04 0 0 0.00 / 991.59 2 2
2 7 2004.88 42 14.12 3087 1831 1.83 / 993.43 2 2
3 13 1737.52 19 14.16 2753 741 2.57 / 994.17 2 3
4 13 1181.88 19 14.36 1994 544 3.12 / 994.71 2 2
5 13 482.24 19 14.69 1074 300 3.42 / 995.01 2 4
6 13 109.00 19 14.92 473 134 3.55 / 995.14 2 2
7 8 0.00 175 14.93 312 815 4.36 / 995.96 2 2
Average= 4.27
(KJ/cycle)

Cycle 231 GMT 16/11/2023 2: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 27 15.05 0 0 0.00 / 987.21 2 2
2 3 1032.84 1 15.38 0 0 0.00 / 987.21 2 2
3 7 2003.00 42 14.12 3089 1832 1.83 / 989.05 2 2
4 13 1737.04 19 14.17 2723 733 2.57 / 989.78 2 2
5 13 1163.92 19 14.37 1968 537 3.10 / 990.32 2 2
6 13 599.32 19 14.62 1227 341 3.44 / 990.66 2 3
7 13 84.08 19 14.93 435 123 3.57 / 990.78 2 2
8 8 -0.04 175 14.92 312 815 4.38 / 991.59 2 2
Average= 4.27
(KJ/cycle)

Cycle 230 GMT 6/11/2023 2:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 27 15.03 0 0 0.00 / 982.86 2 2
2 7 2008.40 43 14.11 3104 1883 1.88 / 984.74 2 2
3 13 1743.80 19 14.15 2754 740 2.62 / 985.48 2 2
4 13 1136.20 19 14.38 1948 532 3.16 / 986.01 2 3
5 13 422.68 19 14.72 985 275 3.43 / 986.29 2 3
6 13 71.80 19 14.94 417 118 3.55 / 986.41 2 2
7 8 -0.08 175 14.93 309 807 4.36 / 987.21 2 2
Average= 4.27
(KJ/cycle)

Cycle 229 GMT 27/10/2023 2:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 27 15.03 0 0 0.00 / 978.42 2 2
2 7 2006.08 42 14.12 3098 1837 1.84 / 980.26 2 2
3 13 1610.88 19 14.21 2570 694 2.53 / 980.95 2 3
4 13 1190.40 19 14.35 2001 546 3.08 / 981.50 2 3
5 13 754.64 19 14.53 1435 396 3.47 / 981.90 2 4
6 13 137.48 19 14.89 515 146 3.62 / 982.04 2 2
7 8 0.04 175 14.91 312 814 4.43 / 982.86 2 2
Average= 4.27
(KJ/cycle)

Cycle 228 GMT 17/10/2023 3: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 27 15.03 0 0 0.00 / 974.07 2 2
2 7 2003.40 42 14.14 3055 1814 1.81 / 975.88 2 2
3 13 1726.40 19 14.17 2722 733 2.55 / 976.62 2 2
4 13 1128.44 19 14.38 1933 528 3.08 / 977.15 2 3
5 13 562.56 19 14.63 1170 325 3.40 / 977.47 2 4
6 13 130.32 19 14.89 505 143 3.54 / 977.61 2 2
7 8 0.04 175 14.92 310 809 4.35 / 978.42 2 2
Average= 4.27
(KJ/cycle)

Cycle 227 GMT 7/10/2023 3:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 28 15.03 0 0 0.00 / 969.74 2 2
2 3 965.92 -1 15.38 0 0 0.00 / 969.74 2 2
3 7 2004.68 42 14.13 3079 1827 1.83 / 971.57 2 2
4 13 1593.28 19 14.21 2561 691 2.52 / 972.26 2 2
5 13 1136.68 19 14.37 1938 529 3.05 / 972.79 2 2
6 13 559.60 19 14.63 1170 325 3.37 / 973.11 2 3
7 13 131.96 19 14.89 508 144 3.52 / 973.26 2 2
8 8 0.08 175 14.92 311 812 4.33 / 974.07 2 2
Average= 4.27
(KJ/cycle)

Cycle 226 GMT 27/ 9/2023 4:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 28 15.03 0 0 0.00 / 965.36 2 2
2 7 2003.16 43 14.12 3086 1874 1.87 / 967.23 2 2
3 13 1741.44 19 14.15 2773 746 2.62 / 967.97 2 2
4 13 1143.80 19 14.37 1957 534 3.15 / 968.51 2 3
5 13 443.40 19 14.70 1018 284 3.44 / 968.79 2 4
6 13 83.40 19 14.93 436 124 3.56 / 968.92 2 2
7 8 0.24 175 14.92 316 825 4.39 / 969.74 2 2
Average= 4.27
(KJ/cycle)

Cycle 225 GMT 17/ 9/2023 4:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 27 15.04 0 0 0.00 / 961.08 2 2
2 3 1030.32 1 15.37 0 0 0.00 / 961.08 2 2
3 7 2005.36 42 14.13 3085 1831 1.83 / 962.91 2 2
4 13 1591.80 19 14.22 2552 689 2.52 / 963.60 2 3
5 13 1034.24 19 14.41 1801 493 3.01 / 964.09 2 5
6 13 605.32 19 14.60 1229 341 3.35 / 964.43 2 2
7 13 38.00 19 14.95 365 104 3.46 / 964.54 2 2
8 8 0.04 175 14.92 314 820 4.28 / 965.36 2 2
Average= 4.27
(KJ/cycle)

Cycle 224 GMT 7/ 9/2023 5:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 28 15.02 0 0 0.00 / 956.75 2 2
2 3 970.60 -1 15.38 0 0 0.00 / 956.75 2 2
3 7 2007.40 42 14.13 3098 1839 1.84 / 958.59 2 2
4 13 1745.60 19 14.17 2736 737 2.58 / 959.33 2 2
5 13 1048.68 19 14.41 1834 502 3.08 / 959.83 2 3
6 13 487.36 19 14.67 1070 298 3.38 / 960.13 2 2
7 13 98.40 19 14.91 457 129 3.50 / 960.26 2 2
8 8 0.12 175 14.91 315 822 4.33 / 961.08 2 5
Average= 4.27
(KJ/cycle)

Cycle 223 GMT 28/ 8/2023 5:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 28 15.03 0 0 0.00 / 952.36 2 2
2 7 2003.04 43 14.12 3081 1871 1.87 / 954.23 2 2
3 13 1732.20 19 14.16 2755 741 2.61 / 954.97 2 2
4 13 1018.44 19 14.43 1791 491 3.10 / 955.47 2 4
5 13 581.48 19 14.61 1210 336 3.44 / 955.80 2 3
6 13 65.24 19 14.93 412 117 3.56 / 955.92 2 2
7 8 0.04 175 14.91 319 832 4.39 / 956.75 2 2
Average= 4.27
(KJ/cycle)

Cycle 222 GMT 18/ 8/2023 6:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 28 15.03 0 0 0.00 / 948.14 2 2
2 7 2009.60 42 14.13 3079 1827 1.83 / 949.97 2 2
3 13 1470.68 19 14.26 2383 646 2.47 / 950.62 2 3
4 13 1050.92 19 14.40 1837 503 2.98 / 951.12 2 3
5 13 495.16 19 14.66 1083 302 3.28 / 951.42 2 3
6 13 95.60 19 14.91 452 128 3.41 / 951.55 2 2
7 8 0.16 175 14.90 312 814 4.22 / 952.36 2 2
Average= 4.27
(KJ/cycle)

Cycle 221 GMT 8/ 8/2023 6:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 27 15.04 0 0 0.00 / 943.81 2 2
2 3 1019.32 1 15.38 0 0 0.00 / 943.81 2 2
3 7 2005.28 42 14.13 3097 1838 1.84 / 945.65 2 2
4 13 1600.00 19 14.21 2575 695 2.53 / 946.34 2 3
5 13 1040.48 19 14.41 1819 498 3.03 / 946.84 2 3
6 13 610.44 19 14.59 1251 347 3.38 / 947.19 2 3
7 13 91.40 19 14.91 454 129 3.51 / 947.31 2 2
8 8 -0.04 175 14.91 318 830 4.34 / 948.14 2 2
Average= 4.27
(KJ/cycle)

Cycle 220 GMT 29/ 7/2023 6:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 27 15.02 0 0 0.00 / 939.46 2 2
2 7 2010.16 42 14.13 3103 1842 1.84 / 941.30 2 2
3 13 1610.16 19 14.21 2569 694 2.54 / 941.99 2 2
4 13 1191.68 19 14.34 2026 552 3.09 / 942.54 2 3
5 13 491.40 19 14.66 1083 302 3.39 / 942.85 2 2
6 13 107.44 19 14.90 476 135 3.52 / 942.98 2 2
7 8 0.20 175 14.91 317 827 4.35 / 943.81 2 2
Average= 4.27
(KJ/cycle)

Cycle 219 GMT 19/ 7/2023 6:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 28 15.02 0 0 0.00 / 935.12 2 2
2 7 2007.60 42 14.13 3086 1831 1.83 / 936.95 2 2
3 13 1582.40 19 14.21 2522 681 2.51 / 937.63 2 2
4 13 1144.64 19 14.36 1957 534 3.05 / 938.16 2 4
5 13 572.44 19 14.61 1194 331 3.38 / 938.50 2 4
6 13 125.60 19 14.88 503 142 3.52 / 938.64 2 2
7 8 -0.08 175 14.91 314 819 4.34 / 939.46 2 2
Average= 4.27
(KJ/cycle)

Cycle 218 GMT 9/ 7/2023 7:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 28 15.03 0 0 0.00 / 930.62 2 2
2 7 2008.28 42 14.13 3104 1842 1.84 / 932.47 2 2
3 13 1876.76 19 14.13 2943 790 2.63 / 933.26 2 2
4 13 1033.00 19 14.42 1822 499 3.13 / 933.76 2 3
5 13 740.88 19 14.53 1420 392 3.52 / 934.15 2 3
6 13 131.84 19 14.89 508 144 3.67 / 934.29 2 2
7 8 0.12 175 14.90 317 827 4.49 / 935.12 2 2
Average= 4.27
(KJ/cycle)

Cycle 217 GMT 29/ 6/2023 7:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 28 15.03 0 0 0.00 / 926.39 2 2
2 7 2005.20 42 14.13 3097 1838 1.84 / 928.22 2 2
3 13 1473.72 19 14.26 2374 643 2.48 / 928.87 2 2
4 13 1063.00 19 14.40 1839 503 2.98 / 929.37 2 3
5 13 497.96 19 14.65 1091 304 3.29 / 929.67 2 3
6 13 106.72 19 14.90 470 133 3.42 / 929.81 2 2
7 8 0.16 175 14.90 313 816 4.24 / 930.62 2 2
Average= 4.27
(KJ/cycle)

Cycle 216 GMT 19/ 6/2023 8:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 28 15.03 0 0 0.00 / 921.86 2 2
2 7 2021.84 42 14.13 3124 1854 1.85 / 923.72 2 2
3 13 1902.56 19 14.10 2983 799 2.65 / 924.52 2 2
4 13 1283.00 19 14.30 2134 580 3.23 / 925.10 2 2
5 13 533.76 19 14.63 1144 318 3.55 / 925.41 2 2
6 13 128.56 19 14.89 511 145 3.70 / 925.56 2 2
7 8 0.00 175 14.91 317 827 4.52 / 926.39 2 2
Average= 4.27
(KJ/cycle)

Cycle 215 GMT 9/ 6/2023 8:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 28 15.03 0 0 0.00 / 917.38 2 2
2 7 2011.72 42 14.14 3075 1826 1.83 / 919.20 2 2
3 13 1884.64 19 14.10 2974 797 2.62 / 920.00 2 2
4 13 1293.96 19 14.31 2130 579 3.20 / 920.58 2 2
5 13 552.36 19 14.62 1168 324 3.53 / 920.90 2 2
6 13 128.16 19 14.89 507 143 3.67 / 921.05 2 2
7 8 0.16 175 14.91 313 817 4.49 / 921.86 2 2
Average= 4.27
(KJ/cycle)

Cycle 214 GMT 30/ 5/2023 8:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 28 15.03 0 0 0.00 / 913.07 2 2
2 7 2002.36 43 14.13 3086 1875 1.88 / 914.94 2 2
3 13 1722.96 19 14.16 2749 740 2.61 / 915.68 2 2
4 13 1000.80 19 14.42 1776 487 3.10 / 916.17 2 2
5 13 448.00 19 14.68 1028 287 3.39 / 916.45 2 2
6 13 85.64 19 14.92 433 123 3.51 / 916.58 2 2
7 8 0.00 175 14.91 307 801 4.31 / 917.38 2 2
Average= 4.27
(KJ/cycle)

Cycle 213 GMT 20/ 5/2023 9:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 28 15.03 0 0 0.00 / 908.76 2 2
2 7 2006.96 42 14.15 3059 1818 1.82 / 910.58 2 2
3 13 1744.28 19 14.16 2763 743 2.56 / 911.33 2 2
4 13 1042.56 19 14.40 1839 503 3.06 / 911.83 2 3
5 13 494.48 19 14.65 1087 303 3.37 / 912.13 2 2
6 13 101.12 19 14.91 458 130 3.50 / 912.26 2 2
7 8 0.12 175 14.92 308 804 4.30 / 913.07 2 2
Average= 4.27
(KJ/cycle)

Cycle 212 GMT 10/ 5/2023 9:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 28 15.03 0 0 0.00 / 904.50 2 2
2 7 2004.72 42 14.14 3089 1834 1.83 / 906.33 2 2
3 13 1606.00 19 14.21 2564 692 2.53 / 907.02 2 2
4 13 1062.80 19 14.39 1846 505 3.03 / 907.53 2 2
5 13 520.00 19 14.64 1127 313 3.34 / 907.84 2 3
6 13 62.80 19 14.93 401 114 3.46 / 907.96 2 2
7 8 0.24 175 14.92 310 809 4.27 / 908.76 2 2
Average= 4.27
(KJ/cycle)

Cycle 211 GMT 30/ 4/2023 10: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 28 15.04 0 0 0.00 / 900.10 2 2
2 7 2003.76 42 14.13 3079 1827 1.83 / 901.93 2 2
3 13 1874.40 19 14.11 2946 790 2.62 / 902.72 2 2
4 13 1034.08 19 14.41 1821 499 3.12 / 903.22 2 2
5 13 355.04 19 14.75 868 243 3.36 / 903.46 2 2
6 13 103.96 19 14.91 465 132 3.49 / 903.59 2 2
7 13 22.16 19 14.95 336 95 3.59 / 903.69 2 2
8 8 0.12 175 14.91 310 809 4.39 / 904.50 2 2
Average= 4.27
(KJ/cycle)

Cycle 210 GMT 20/ 4/2023 10:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 28 15.02 0 0 0.00 / 895.73 2 2
2 7 2005.80 42 14.15 3061 1819 1.82 / 897.54 2 2
3 13 1740.52 19 14.16 2759 742 2.56 / 898.29 2 2
4 13 1180.60 19 14.34 2007 547 3.11 / 898.83 2 2
5 13 593.28 19 14.60 1221 339 3.45 / 899.17 2 2
6 13 81.80 19 14.92 435 123 3.57 / 899.30 2 2
7 8 0.12 175 14.91 309 806 4.38 / 900.10 2 2
Average= 4.27
(KJ/cycle)

Cycle 209 GMT 10/ 4/2023 10:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 28 15.03 0 0 0.00 / 891.49 2 2
2 7 2002.84 43 14.14 3083 1875 1.87 / 893.36 2 2
3 13 1581.68 19 14.21 2550 688 2.56 / 894.05 2 2
4 13 899.60 19 14.47 1637 450 3.01 / 894.50 2 2
5 13 480.32 19 14.66 1066 297 3.31 / 894.80 2 2
6 13 93.12 19 14.91 445 126 3.44 / 894.92 2 2
7 8 0.24 175 14.91 308 804 4.24 / 895.73 2 2
Average= 4.27
(KJ/cycle)

Cycle 208 GMT 31/ 3/2023 11:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 28 15.04 0 0 0.00 / 887.20 2 2
2 7 2002.40 42 14.14 3090 1835 1.84 / 889.03 2 2
3 13 1591.00 19 14.21 2565 693 2.53 / 889.72 2 2
4 13 1171.12 19 14.34 1985 541 3.07 / 890.26 2 2
5 13 458.12 19 14.67 1039 290 3.36 / 890.55 2 2
6 13 87.08 19 14.91 442 125 3.48 / 890.68 2 2
7 8 0.00 175 14.92 309 807 4.29 / 891.49 2 2
Average= 4.27
(KJ/cycle)

Cycle 207 GMT 21/ 3/2023 11:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 28 15.02 0 0 0.00 / 882.82 2 2
2 7 2009.88 42 14.14 3104 1843 1.84 / 884.66 2 2
3 13 1749.64 19 14.16 2756 741 2.58 / 885.41 2 2
4 13 1183.80 19 14.34 2006 547 3.13 / 885.95 2 2
5 13 466.80 19 14.67 1051 293 3.42 / 886.25 2 2
6 13 96.00 19 14.91 458 130 3.55 / 886.38 2 2
7 8 0.20 175 14.92 314 820 4.37 / 887.20 2 2
Average= 4.27
(KJ/cycle)

Cycle 206 GMT 11/ 3/2023 11:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 28 15.03 0 0 0.00 / 878.32 2 2
2 7 2008.12 42 14.15 3080 1830 1.83 / 880.15 2 2
3 13 1608.88 19 14.21 2568 693 2.52 / 880.84 2 2
4 13 1334.76 19 14.27 2201 597 3.12 / 881.44 2 2
5 13 571.16 19 14.60 1195 331 3.45 / 881.77 2 2
6 13 129.40 19 14.88 512 145 3.60 / 881.92 2 2
7 13 25.20 19 14.93 343 97 3.69 / 882.01 2 2
8 8 0.08 175 14.89 310 808 4.50 / 882.82 2 2
Average= 4.26
(KJ/cycle)

Cycle 205 GMT 1/ 3/2023 12:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 28 15.03 0 0 0.00 / 873.90 2 2
2 7 2005.60 43 14.14 3087 1877 1.88 / 875.78 2 2
3 13 1732.48 19 14.16 2743 738 2.61 / 876.52 2 2
4 13 1138.20 19 14.36 1940 529 3.14 / 877.05 2 2
5 13 550.44 19 14.62 1160 322 3.47 / 877.37 2 2
6 13 120.40 19 14.89 495 140 3.61 / 877.51 2 2
7 8 0.04 175 14.91 310 809 4.42 / 878.32 2 2
Average= 4.26
(KJ/cycle)

Cycle 204 GMT 19/ 2/2023 13:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 28 15.03 0 0 0.00 / 869.68 2 2
2 7 2006.44 43 14.14 3087 1877 1.88 / 871.55 2 2
3 13 1606.92 19 14.20 2568 693 2.57 / 872.25 2 2
4 13 1027.64 19 14.40 1803 493 3.06 / 872.74 2 2
5 13 361.24 19 14.74 885 248 3.31 / 872.99 2 2
6 13 55.16 19 14.94 391 111 3.42 / 873.10 2 2
7 8 0.12 175 14.92 309 807 4.23 / 873.90 2 2
Average= 4.26
(KJ/cycle)

Cycle 203 GMT 9/ 2/2023 13:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 28 15.03 0 0 0.00 / 865.40 2 2
2 7 2007.48 42 14.14 3091 1836 1.84 / 867.23 2 2
3 13 1732.92 19 14.17 2741 738 2.57 / 867.97 2 2
4 13 1018.20 19 14.41 1783 488 3.06 / 868.46 2 2
5 13 456.56 19 14.67 1036 289 3.35 / 868.75 2 2
6 13 85.08 19 14.91 436 124 3.47 / 868.87 2 2
7 8 0.00 175 14.91 309 806 4.28 / 869.68 2 2
Average= 4.26
(KJ/cycle)

Cycle 202 GMT 30/ 1/2023 13:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 28 15.03 0 0 0.00 / 861.04 2 2
2 7 2004.12 42 14.16 3057 1818 1.82 / 862.85 2 2
3 13 1727.84 19 14.17 2753 741 2.56 / 863.60 2 2
4 13 1126.00 19 14.36 1938 529 3.09 / 864.12 2 2
5 13 544.20 19 14.62 1161 323 3.41 / 864.45 2 2
6 13 117.04 19 14.89 491 139 3.55 / 864.59 2 2
7 8 0.12 175 14.91 310 809 4.36 / 865.40 2 2
Average= 4.26
(KJ/cycle)

Cycle 201 GMT 20/ 1/2023 14:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 28 15.03 0 0 0.00 / 856.73 2 2
2 7 2002.52 42 14.15 3073 1826 1.83 / 858.55 2 2
3 13 1725.92 19 14.17 2724 733 2.56 / 859.29 2 2
4 13 1149.96 19 14.35 1955 533 3.09 / 859.82 2 2
5 13 450.80 19 14.68 1023 285 3.38 / 860.11 2 2
6 13 87.08 19 14.92 439 124 3.50 / 860.23 2 2
7 8 0.12 175 14.92 309 807 4.31 / 861.04 2 2
Average= 4.26
(KJ/cycle)

Cycle 200 GMT 10/ 1/2023 14:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 28 15.04 0 0 0.00 / 852.36 2 2
2 7 2003.72 42 14.16 3052 1815 1.82 / 854.17 2 2
3 13 1732.12 19 14.17 2740 738 2.55 / 854.91 2 2
4 13 1144.08 19 14.36 1951 532 3.09 / 855.44 2 2
5 13 574.48 19 14.60 1200 333 3.42 / 855.77 2 2
6 13 130.56 19 14.88 510 144 3.56 / 855.92 2 2
7 8 0.08 175 14.90 310 808 4.37 / 856.73 2 2
Average= 4.26
(KJ/cycle)

Cycle 199 GMT 31/12/2022 14:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 28 15.02 0 0 0.00 / 848.07 2 2
2 7 2011.04 42 14.15 3093 1838 1.84 / 849.91 2 2
3 13 1625.48 19 14.20 2590 699 2.54 / 850.61 2 2
4 13 1064.72 19 14.38 1849 505 3.04 / 851.11 2 2
5 13 513.16 19 14.64 1110 309 3.35 / 851.42 2 2
6 13 110.28 19 14.89 477 135 3.49 / 851.56 2 2
7 8 0.08 175 14.91 307 801 4.29 / 852.36 2 2
Average= 4.26
(KJ/cycle)

Cycle 198 GMT 21/12/2022 15:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 28 15.03 0 0 0.00 / 843.77 2 2
2 7 2008.64 42 14.15 3092 1838 1.84 / 845.60 2 2
3 13 1616.72 19 14.21 2570 694 2.53 / 846.30 2 2
4 13 1063.32 19 14.38 1854 507 3.04 / 846.81 2 2
5 13 501.64 19 14.64 1096 305 3.34 / 847.11 2 2
6 13 103.84 19 14.90 471 133 3.48 / 847.24 2 2
7 8 0.16 175 14.90 317 827 4.30 / 848.07 2 2
Average= 4.26
(KJ/cycle)

Cycle 197 GMT 11/12/2022 15:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 28 15.02 0 0 0.00 / 839.42 2 2
2 7 2006.12 42 14.16 3072 1827 1.83 / 841.25 2 2
3 13 1759.56 19 14.16 2777 747 2.57 / 841.99 2 2
4 13 1057.48 19 14.40 1847 505 3.08 / 842.50 2 2
5 13 501.04 19 14.65 1100 306 3.39 / 842.80 2 2
6 13 102.36 19 14.90 472 134 3.52 / 842.94 2 2
7 8 0.08 175 14.91 318 830 4.35 / 843.77 2 2
Average= 4.26
(KJ/cycle)

Cycle 196 GMT 1/12/2022 15:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 27 15.02 0 0 0.00 / 835.09 2 2
2 3 1036.40 1 15.39 0 0 0.00 / 835.09 2 2
3 7 2007.20 42 14.15 3075 1827 1.83 / 836.92 2 2
4 13 1597.56 19 14.21 2550 688 2.52 / 837.61 2 2
5 13 1028.80 19 14.40 1815 497 3.01 / 838.10 2 2
6 13 594.32 19 14.59 1227 340 3.35 / 838.44 2 2
7 13 140.48 19 14.87 529 149 3.50 / 838.59 2 2
8 8 0.04 175 14.90 317 827 4.33 / 839.42 2 2
Average= 4.26
(KJ/cycle)

Cycle 195 GMT 21/11/2022 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 27 15.01 0 0 0.00 / 830.59 2 2
2 7 2004.68 42 14.17 3048 1814 1.81 / 832.40 2 2
3 13 1748.20 19 14.17 2747 740 2.55 / 833.14 2 2
4 13 1310.64 19 14.28 2188 594 3.15 / 833.74 2 2
5 13 703.12 19 14.53 1372 379 3.53 / 834.12 2 2
6 13 121.72 19 14.88 501 142 3.67 / 834.26 2 2
7 8 0.12 175 14.90 319 832 4.50 / 835.09 2 2
Average= 4.26
(KJ/cycle)

Cycle 194 GMT 11/11/2022 16:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 28 15.02 0 0 0.00 / 826.32 2 2
2 3 971.20 -1 15.41 0 0 0.00 / 826.32 2 2
3 7 2008.16 42 14.16 3070 1826 1.83 / 828.15 2 2
4 13 1597.08 19 14.21 2565 693 2.52 / 828.84 2 2
5 13 1046.68 19 14.39 1836 502 3.02 / 829.34 2 2
6 13 478.48 19 14.65 1071 298 3.32 / 829.64 2 3
7 13 93.56 19 14.90 458 130 3.45 / 829.77 2 2
8 8 0.00 175 14.90 314 819 4.27 / 830.59 2 2
Average= 4.26
(KJ/cycle)

Cycle 193 GMT 1/11/2022 17:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 28 15.02 0 0 0.00 / 822.06 2 2
2 7 2003.56 42 14.16 3090 1838 1.84 / 823.90 2 2
3 13 1477.16 19 14.25 2381 645 2.48 / 824.54 2 2
4 13 1211.32 19 14.32 2046 557 3.04 / 825.10 2 2
5 13 500.12 19 14.64 1094 304 3.34 / 825.40 2 3
6 13 59.72 19 14.93 398 113 3.46 / 825.52 2 2
7 8 0.12 175 14.90 310 808 4.26 / 826.32 2 2
Average= 4.26
(KJ/cycle)

Cycle 192 GMT 22/10/2022 17:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 28 15.02 0 0 0.00 / 817.71 2 2
2 7 2005.12 43 14.15 3078 1873 1.87 / 819.58 2 2
3 13 1734.20 19 14.17 2755 742 2.61 / 820.32 2 2
4 13 1001.60 19 14.41 1762 482 3.10 / 820.81 2 2
5 13 575.64 19 14.60 1197 332 3.43 / 821.14 2 2
6 13 32.32 19 14.94 355 101 3.53 / 821.24 2 2
7 8 0.00 175 14.90 314 819 4.35 / 822.06 2 2
Average= 4.26
(KJ/cycle)

Cycle 191 GMT 12/10/2022 18:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 28 15.01 0 0 0.00 / 813.52 2 2
2 7 2003.92 42 14.16 3087 1836 1.84 / 815.35 2 2
3 13 1482.32 19 14.25 2408 652 2.49 / 816.01 2 2
4 13 958.44 19 14.43 1717 471 2.96 / 816.48 2 4
5 13 539.48 19 14.62 1144 318 3.28 / 816.79 2 2
6 13 16.40 19 14.95 332 94 3.37 / 816.89 2 2
7 8 0.12 175 14.90 315 821 4.19 / 817.71 2 2
Average= 4.26
(KJ/cycle)

Cycle 190 GMT 2/10/2022 18:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 28 15.02 0 0 0.00 / 809.28 2 2
2 7 2003.52 42 14.16 3071 1826 1.83 / 811.10 2 2
3 13 1599.96 19 14.22 2545 688 2.51 / 811.79 2 2
4 13 1026.72 19 14.40 1803 493 3.01 / 812.28 2 4
5 13 459.72 19 14.66 1033 288 3.30 / 812.57 2 4
6 13 85.36 19 14.90 443 125 3.42 / 812.70 2 2
7 8 0.00 175 14.89 315 821 4.24 / 813.52 2 3
Average= 4.26
(KJ/cycle)

Cycle 189 GMT 22/ 9/2022 18:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 28 15.01 0 0 0.00 / 804.99 2 2
2 7 2008.52 42 14.16 3090 1838 1.84 / 806.83 2 2
3 13 1607.16 19 14.20 2567 693 2.53 / 807.52 2 3
4 13 1043.84 19 14.39 1821 498 3.03 / 808.02 2 7
5 13 493.56 19 14.65 1078 300 3.33 / 808.32 2 2
6 13 101.96 19 14.90 471 133 3.46 / 808.45 2 2
7 8 -0.04 175 14.89 317 826 4.29 / 809.28 2 2
Average= 4.26
(KJ/cycle)

Cycle 188 GMT 12/ 9/2022 19: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 28 15.02 0 0 0.00 / 800.64 2 2
2 7 2005.32 42 14.16 3082 1833 1.83 / 802.47 2 2
3 13 1619.32 19 14.21 2583 697 2.53 / 803.17 2 2
4 13 1211.88 19 14.31 2035 553 3.08 / 803.72 2 2
5 13 499.40 19 14.65 1085 302 3.39 / 804.02 2 2
6 13 103.52 19 14.90 474 134 3.52 / 804.16 2 2
7 8 0.12 175 14.89 319 831 4.35 / 804.99 2 2
Average= 4.26
(KJ/cycle)

Cycle 187 GMT 2/ 9/2022 19:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 27 15.02 0 0 0.00 / 796.34 2 2
2 10 1020.04 3 15.36 0 0 0.00 / 796.34 2 2
3 3 949.48 -1 15.38 0 0 0.00 / 796.34 2 2
4 7 2003.52 42 14.16 3076 1829 1.83 / 798.17 2 2
5 13 1732.16 19 14.18 2739 738 2.57 / 798.91 2 3
6 13 1028.92 19 14.40 1804 494 3.06 / 799.40 2 8
7 13 468.52 19 14.66 1048 292 3.35 / 799.69 2 2
8 13 79.36 19 14.90 435 123 3.48 / 799.81 2 2
9 8 0.08 175 14.89 316 823 4.30 / 800.64 2 2
Average= 4.26
(KJ/cycle)

Cycle 186 GMT 23/ 8/2022 19:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 28 15.00 0 0 0.00 / 792.09 2 2
2 3 961.04 -1 15.39 0 0 0.00 / 792.09 2 2
3 7 2004.88 42 14.17 3051 1816 1.82 / 793.90 2 2
4 13 1587.56 19 14.21 2544 687 2.50 / 794.59 2 3
5 13 1031.76 19 14.40 1796 491 2.99 / 795.08 2 4
6 13 471.40 19 14.66 1056 294 3.29 / 795.38 2 3
7 13 89.12 19 14.90 454 129 3.42 / 795.51 2 2
8 8 0.08 175 14.89 320 834 4.25 / 796.34 2 2
Average= 4.26
(KJ/cycle)

Cycle 185 GMT 13/ 8/2022 19:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 28 15.01 0 0 0.00 / 787.76 2 2
2 7 2002.96 42 14.17 3074 1829 1.83 / 789.59 2 2
3 13 1583.72 19 14.23 2519 681 2.51 / 790.27 2 2
4 13 1161.96 19 14.34 1961 534 3.04 / 790.81 2 4
5 13 588.48 19 14.59 1208 335 3.38 / 791.14 2 3
6 13 72.92 19 14.91 423 120 3.50 / 791.26 2 2
7 8 0.08 175 14.89 317 826 4.33 / 792.09 2 2
Average= 4.26
(KJ/cycle)

Cycle 184 GMT 3/ 8/2022 20:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 28 15.01 0 0 0.00 / 783.45 2 2
2 3 1021.20 1 15.39 0 0 0.00 / 783.45 2 2
3 7 2003.52 42 14.17 3079 1832 1.83 / 785.29 2 2
4 13 1733.12 19 14.17 2749 740 2.57 / 786.03 2 2
5 13 1023.92 19 14.40 1801 493 3.07 / 786.52 2 3
6 13 457.72 19 14.67 1042 290 3.36 / 786.81 2 3
7 13 89.04 19 14.91 448 127 3.48 / 786.94 2 2
8 8 0.20 175 14.90 317 827 4.31 / 787.76 2 2
Average= 4.26
(KJ/cycle)

Cycle 183 GMT 24/ 7/2022 20:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 28 15.00 0 0 0.00 / 779.09 2 2
2 7 2002.40 42 14.17 3061 1822 1.82 / 780.91 2 2
3 13 1729.28 19 14.18 2714 731 2.55 / 781.64 2 2
4 13 1161.80 19 14.34 1971 537 3.09 / 782.18 2 4
5 13 575.84 19 14.60 1194 331 3.42 / 782.51 2 5
6 13 75.12 19 14.91 426 121 3.54 / 782.63 2 2
7 8 -0.04 175 14.89 316 823 4.37 / 783.45 2 2
Average= 4.26
(KJ/cycle)

Cycle 182 GMT 14/ 7/2022 21:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 28 15.00 0 0 0.00 / 774.62 2 2
2 7 2002.44 42 14.17 3074 1829 1.83 / 776.45 2 2
3 13 1610.84 19 14.21 2565 693 2.52 / 777.14 2 3
4 13 1195.00 19 14.33 1995 543 3.07 / 777.68 2 4
5 13 637.56 19 14.57 1274 353 3.42 / 778.03 2 4
6 13 90.92 19 14.90 451 128 3.55 / 778.16 2 2
7 13 16.60 19 14.93 337 96 3.64 / 778.26 2 2
8 8 0.08 175 14.88 319 831 4.47 / 779.09 2 2
Average= 4.26
(KJ/cycle)

Cycle 181 GMT 4/ 7/2022 21:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 28 15.01 0 0 0.00 / 770.26 2 2
2 7 2005.08 42 14.17 3080 1833 1.83 / 772.09 2 2
3 13 1732.32 19 14.19 2728 735 2.57 / 772.82 2 2
4 13 1052.28 19 14.39 1826 499 3.07 / 773.32 2 4
5 13 623.40 19 14.57 1263 350 3.42 / 773.67 2 2
6 13 82.56 19 14.90 443 125 3.54 / 773.80 2 2
7 8 0.08 175 14.89 314 818 4.36 / 774.62 2 2
Average= 4.26
(KJ/cycle)

Cycle 180 GMT 24/ 6/2022 22: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 28 15.01 0 0 0.00 / 765.93 2 2
2 7 2007.08 42 14.17 3083 1835 1.83 / 767.77 2 2
3 13 1742.80 19 14.17 2762 744 2.58 / 768.51 2 2
4 13 1017.72 19 14.40 1787 489 3.07 / 769.00 2 2
5 13 460.96 19 14.67 1043 291 3.36 / 769.29 2 4
6 13 88.48 19 14.90 450 127 3.49 / 769.42 2 2
7 8 0.12 175 14.89 321 836 4.32 / 770.26 2 2
Average= 4.26
(KJ/cycle)

Cycle 179 GMT 14/ 6/2022 22:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 28 15.01 0 0 0.00 / 761.58 2 2
2 7 2004.12 42 14.17 3059 1821 1.82 / 763.40 2 2
3 13 1873.44 19 14.14 2939 790 2.61 / 764.19 2 2
4 13 1017.60 19 14.41 1794 491 3.10 / 764.68 2 8
5 13 461.24 19 14.67 1046 292 3.39 / 764.97 2 2
6 13 89.96 19 14.91 461 131 3.52 / 765.10 2 2
7 8 0.04 175 14.90 320 834 4.36 / 765.93 2 2
Average= 4.26
(KJ/cycle)

Cycle 178 GMT 4/ 6/2022 23: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 28 15.02 0 0 0.00 / 757.20 2 2
2 7 2010.36 42 14.18 3033 1806 1.81 / 759.01 2 2
3 13 1739.80 19 14.18 2713 731 2.54 / 759.74 2 2
4 13 1303.88 19 14.28 2146 582 3.12 / 760.32 2 2
5 13 555.60 19 14.61 1161 322 3.44 / 760.64 2 3
6 13 78.56 19 14.91 431 122 3.56 / 760.76 2 2
7 8 0.20 175 14.90 311 811 4.37 / 761.58 2 2
Average= 4.25
(KJ/cycle)

Cycle 177 GMT 25/ 5/2022 23:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 28 15.01 0 0 0.00 / 752.89 2 2
2 7 2003.88 42 14.18 3071 1829 1.83 / 754.71 2 2
3 13 1595.56 19 14.22 2535 685 2.51 / 755.40 2 3
4 13 1174.24 19 14.33 1971 537 3.05 / 755.94 2 4
5 13 588.52 19 14.59 1215 337 3.39 / 756.27 2 7
6 13 83.64 19 14.90 441 125 3.51 / 756.40 2 2
7 8 0.12 175 14.90 308 803 4.32 / 757.20 2 2
Average= 4.25
(KJ/cycle)

Cycle 176 GMT 15/ 5/2022 23:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 28 15.00 0 0 0.00 / 748.59 2 2
2 7 2005.68 42 14.17 3077 1831 1.83 / 750.42 2 2
3 13 1610.92 19 14.21 2565 693 2.52 / 751.11 2 2
4 13 1176.12 19 14.32 1975 537 3.06 / 751.65 2 5
5 13 472.16 19 14.65 1054 293 3.35 / 751.94 2 2
6 13 87.80 19 14.89 451 128 3.48 / 752.07 2 2
7 8 0.16 175 14.89 314 818 4.30 / 752.89 2 3
Average= 4.25
(KJ/cycle)

Cycle 175 GMT 5/ 5/2022 23:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 28 15.02 0 0 0.00 / 744.40 2 2
2 7 2008.80 42 14.17 3091 1840 1.84 / 746.24 2 2
3 13 1467.76 19 14.25 2393 648 2.49 / 746.89 2 2
4 13 921.96 19 14.44 1678 460 2.95 / 747.35 2 3
5 13 504.12 19 14.63 1104 307 3.25 / 747.66 2 2
6 13 58.72 19 14.91 397 112 3.37 / 747.77 2 2
7 8 -0.08 175 14.89 313 816 4.18 / 748.59 2 3
Average= 4.25
(KJ/cycle)

Cycle 174 GMT 26/ 4/2022 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 28 15.00 0 0 0.00 / 740.06 2 2
2 7 2010.04 42 14.17 3093 1841 1.84 / 741.90 2 2
3 13 1747.52 19 14.18 2727 735 2.58 / 742.63 2 2
4 13 1069.20 19 14.38 1868 510 3.09 / 743.14 2 5
5 13 505.08 19 14.64 1102 307 3.39 / 743.45 2 2
6 13 104.92 19 14.89 477 135 3.53 / 743.58 2 2
7 8 0.04 175 14.90 314 819 4.35 / 744.40 2 2
Average= 4.25
(KJ/cycle)

Cycle 173 GMT 16/ 4/2022 0:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 28 15.01 0 0 0.00 / 735.73 2 2
2 7 2003.56 42 14.17 3096 1843 1.84 / 737.57 2 2
3 13 1593.28 19 14.22 2544 687 2.53 / 738.26 2 3
4 13 1183.36 19 14.32 2017 549 3.08 / 738.81 2 4
5 13 460.56 19 14.65 1041 290 3.37 / 739.10 2 3
6 13 86.52 19 14.89 456 129 3.50 / 739.23 2 2
7 8 0.08 175 14.89 318 829 4.33 / 740.06 2 2
Average= 4.25
(KJ/cycle)

Cycle 172 GMT 6/ 4/2022 0:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 28 15.02 0 0 0.00 / 731.42 2 2
2 7 2008.08 42 14.17 3090 1839 1.84 / 733.26 2 2
3 13 1599.24 19 14.22 2548 688 2.53 / 733.95 2 2
4 13 1167.44 19 14.33 1978 539 3.07 / 734.49 2 2
5 13 444.36 19 14.67 1031 287 3.35 / 734.78 2 2
6 13 81.00 19 14.90 445 126 3.48 / 734.90 2 2
7 8 0.12 175 14.90 317 827 4.31 / 735.73 2 2
Average= 4.25
(KJ/cycle)

Cycle 171 GMT 27/ 3/2022 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 28 15.02 0 0 0.00 / 727.05 2 2
2 7 2003.56 43 14.17 3057 1863 1.86 / 728.91 2 2
3 13 1730.92 19 14.18 2729 735 2.60 / 729.64 2 2
4 13 1293.32 19 14.28 2151 584 3.18 / 730.23 2 3
5 13 439.80 19 14.68 1009 281 3.46 / 730.51 2 2
6 13 83.44 19 14.91 434 123 3.59 / 730.63 2 2
7 8 0.24 175 14.91 304 793 4.38 / 731.42 2 2
Average= 4.25
(KJ/cycle)

Cycle 170 GMT 17/ 3/2022 1:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 28 15.01 0 0 0.00 / 722.80 2 2
2 7 2006.20 43 14.16 3083 1877 1.88 / 724.68 2 2
3 13 1596.28 19 14.21 2561 691 2.57 / 725.37 2 2
4 13 1023.92 19 14.39 1791 490 3.06 / 725.86 2 4
5 13 346.00 19 14.74 866 243 3.30 / 726.10 2 2
6 13 101.16 19 14.89 469 133 3.43 / 726.24 2 2
7 8 -0.04 175 14.90 310 808 4.24 / 727.05 2 2
Average= 4.25
(KJ/cycle)

Cycle 169 GMT 7/ 3/2022 1:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 28 15.01 0 0 0.00 / 718.45 2 2
2 7 2001.72 42 14.17 3074 1829 1.83 / 720.28 2 2
3 13 1726.16 19 14.18 2739 738 2.57 / 721.02 2 2
4 13 1124.00 19 14.35 1930 526 3.09 / 721.54 2 3
5 13 557.56 19 14.60 1182 328 3.42 / 721.87 2 2
6 13 69.36 19 14.91 423 120 3.54 / 721.99 2 2
7 8 0.16 175 14.90 312 814 4.35 / 722.80 2 2
Average= 4.25
(KJ/cycle)

Cycle 168 GMT 25/ 2/2022 2: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 28 15.01 0 0 0.00 / 714.10 2 2
2 7 2008.08 42 14.18 3088 1839 1.84 / 715.94 2 2
3 13 1739.28 19 14.19 2753 742 2.58 / 716.69 2 2
4 13 1024.36 19 14.40 1798 492 3.07 / 717.18 2 3
5 13 595.80 19 14.58 1223 339 3.41 / 717.52 2 3
6 13 81.60 19 14.91 440 125 3.54 / 717.64 2 2
7 8 0.16 175 14.90 310 808 4.35 / 718.45 2 2
Average= 4.25
(KJ/cycle)

Cycle 167 GMT 15/ 2/2022 2:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 28 15.01 0 0 0.00 / 709.80 2 2
2 7 2002.88 42 14.18 3074 1831 1.83 / 711.63 2 2
3 13 1729.16 19 14.19 2739 738 2.57 / 712.37 2 2
4 13 1035.52 19 14.40 1811 495 3.06 / 712.86 2 6
5 13 486.44 19 14.65 1079 300 3.37 / 713.16 2 2
6 13 98.32 19 14.89 462 131 3.50 / 713.30 2 2
7 8 0.00 175 14.90 310 808 4.30 / 714.10 2 2
Average= 4.25
(KJ/cycle)

Cycle 166 GMT 5/ 2/2022 3: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 28 15.01 0 0 0.00 / 705.43 2 2
2 7 2008.96 42 14.17 3091 1840 1.84 / 707.27 2 2
3 13 1729.28 19 14.18 2730 736 2.58 / 708.00 2 2
4 13 1151.88 19 14.34 1968 536 3.11 / 708.54 2 2
5 13 581.76 19 14.59 1208 335 3.45 / 708.87 2 2
6 13 76.52 19 14.91 428 121 3.57 / 708.99 2 2
7 8 0.16 175 14.91 309 806 4.37 / 709.80 2 2
Average= 4.25
(KJ/cycle)

Cycle 165 GMT 26/ 1/2022 3:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 28 15.00 0 0 0.00 / 701.15 2 2
2 7 2003.12 42 14.19 3072 1831 1.83 / 702.98 2 2
3 13 1587.32 19 14.23 2531 684 2.52 / 703.67 2 2
4 13 1141.72 19 14.34 1957 533 3.05 / 704.20 2 3
5 13 423.48 19 14.68 1000 279 3.33 / 704.48 2 2
6 13 73.12 19 14.90 433 123 3.45 / 704.60 2 2
7 8 0.08 175 14.89 316 823 4.27 / 705.43 2 2
Average= 4.25
(KJ/cycle)

Cycle 164 GMT 16/ 1/2022 3:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 28 15.00 0 0 0.00 / 696.84 2 2
2 7 2006.28 42 14.18 3096 1844 1.84 / 698.68 2 2
3 13 1732.52 19 14.19 2748 741 2.58 / 699.42 2 2
4 13 1011.40 19 14.41 1785 489 3.07 / 699.91 2 7
5 13 458.84 19 14.67 1041 290 3.36 / 700.20 2 3
6 13 78.88 19 14.90 434 123 3.49 / 700.33 2 2
7 8 0.16 175 14.89 317 826 4.31 / 701.15 2 2
Average= 4.25
(KJ/cycle)

Cycle 163 GMT 6/ 1/2022 4:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 28 15.00 0 0 0.00 / 692.49 2 2
2 7 2003.08 42 14.18 3098 1845 1.85 / 694.33 2 2
3 13 1735.40 19 14.19 2745 740 2.59 / 695.07 2 2
4 13 1163.60 19 14.35 1968 537 3.12 / 695.61 2 3
5 13 465.20 19 14.67 1049 292 3.41 / 695.90 2 2
6 13 85.72 19 14.90 443 125 3.54 / 696.03 2 2
7 8 0.08 175 14.89 312 813 4.35 / 696.84 2 2
Average= 4.25
(KJ/cycle)

Cycle 162 GMT 27/12/2021 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 28 15.00 0 0 0.00 / 688.19 2 2
2 7 2008.84 42 14.18 3093 1842 1.84 / 690.03 2 2
3 13 1582.68 19 14.23 2532 685 2.53 / 690.71 2 2
4 13 1160.00 19 14.34 1968 536 3.06 / 691.25 2 3
5 13 445.24 19 14.67 1018 284 3.35 / 691.53 2 2
6 13 83.16 19 14.90 446 126 3.47 / 691.66 2 2
7 8 0.00 175 14.89 318 829 4.30 / 692.49 2 3
Average= 4.25
(KJ/cycle)

Cycle 161 GMT 17/12/2021 4:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 28 15.01 0 0 0.00 / 683.87 2 2
2 7 2003.52 42 14.18 3082 1836 1.84 / 685.70 2 2
3 13 1606.20 19 14.22 2579 697 2.53 / 686.40 2 2
4 13 1184.68 19 14.32 2004 545 3.08 / 686.94 2 3
5 13 476.96 19 14.66 1061 296 3.37 / 687.24 2 6
6 13 88.28 19 14.90 451 128 3.50 / 687.37 2 2
7 8 0.12 175 14.89 314 818 4.32 / 688.19 2 2
Average= 4.25
(KJ/cycle)

Cycle 160 GMT 7/12/2021 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 28 15.01 0 0 0.00 / 679.59 2 2
2 7 2007.40 42 14.19 3078 1834 1.83 / 681.42 2 2
3 13 1736.32 19 14.19 2743 740 2.57 / 682.16 2 2
4 13 1013.48 19 14.41 1772 485 3.06 / 682.65 2 2
5 13 459.16 19 14.67 1024 285 3.34 / 682.93 2 2
6 13 87.72 19 14.90 441 125 3.47 / 683.06 2 2
7 8 0.04 175 14.89 311 810 4.28 / 683.87 2 2
Average= 4.25
(KJ/cycle)

Cycle 159 GMT 27/11/2021 5:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 28 15.01 0 0 0.00 / 675.29 2 2
2 7 2008.76 43 14.18 3076 1876 1.88 / 677.16 2 2
3 13 1734.16 19 14.18 2751 741 2.62 / 677.90 2 2
4 13 1028.40 19 14.40 1801 493 3.11 / 678.40 2 6
5 13 343.24 19 14.75 845 237 3.35 / 678.63 2 2
6 13 100.40 19 14.90 466 132 3.48 / 678.77 2 2
7 8 0.00 175 14.90 315 821 4.30 / 679.59 2 2
Average= 4.25
(KJ/cycle)

Cycle 158 GMT 17/11/2021 5:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 28 15.00 0 0 0.00 / 670.93 2 2
2 7 2009.32 42 14.18 3091 1841 1.84 / 672.77 2 2
3 13 1598.64 19 14.23 2575 696 2.54 / 673.46 2 2
4 13 1174.92 19 14.33 1984 540 3.08 / 674.00 2 2
5 13 600.60 19 14.59 1233 342 3.42 / 674.34 2 2
6 13 83.36 19 14.90 441 125 3.54 / 674.47 2 2
7 8 0.08 175 14.90 314 819 4.36 / 675.29 2 2
Average= 4.25
(KJ/cycle)

Cycle 157 GMT 7/11/2021 6: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 28 15.00 0 0 0.00 / 666.67 2 2
2 7 2009.52 42 14.19 3054 1820 1.82 / 668.50 2 2
3 13 1494.24 19 14.27 2404 652 2.47 / 669.15 2 3
4 13 1084.88 19 14.38 1867 510 2.98 / 669.66 2 4
5 13 518.64 19 14.63 1117 310 3.29 / 669.97 2 3
6 13 107.04 19 14.89 477 135 3.43 / 670.10 2 2
7 8 0.08 175 14.88 316 823 4.25 / 670.93 2 2
Average= 4.25
(KJ/cycle)

Cycle 156 GMT 28/10/2021 6:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 28 15.01 0 0 0.00 / 662.45 2 2
2 7 2004.04 42 14.18 3075 1831 1.83 / 664.28 2 2
3 13 1476.12 19 14.27 2401 651 2.48 / 664.93 2 2
4 13 1059.40 19 14.39 1835 502 2.98 / 665.43 2 2
5 13 502.40 19 14.64 1094 304 3.29 / 665.74 2 5
6 13 102.52 19 14.90 466 132 3.42 / 665.87 2 2
7 8 -0.04 175 14.89 310 808 4.23 / 666.67 2 2
Average= 4.25
(KJ/cycle)

Cycle 155 GMT 18/10/2021 6:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 28 15.01 0 0 0.00 / 658.14 2 2
2 7 2005.60 42 14.20 3036 1811 1.81 / 659.95 2 2
3 13 1747.48 19 14.20 2734 738 2.55 / 660.69 2 2
4 13 1172.72 19 14.35 1985 541 3.09 / 661.23 2 4
5 13 434.40 19 14.69 1000 279 3.37 / 661.51 2 5
6 13 77.40 19 14.92 429 122 3.49 / 661.63 2 2
7 8 0.16 175 14.90 314 819 4.31 / 662.45 2 3
Average= 4.25
(KJ/cycle)

Cycle 154 GMT 8/10/2021 6:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 28 15.01 0 0 0.00 / 653.78 2 2
2 7 2008.24 42 14.20 3068 1830 1.83 / 655.61 2 2
3 13 1739.32 19 14.20 2749 742 2.57 / 656.35 2 2
4 13 1179.00 19 14.35 1990 543 3.11 / 656.89 2 2
5 13 474.96 19 14.67 1061 296 3.41 / 657.19 2 3
6 13 99.72 19 14.91 462 131 3.54 / 657.32 2 2
7 8 0.16 175 14.91 314 819 4.36 / 658.14 2 2
Average= 4.25
(KJ/cycle)

Cycle 153 GMT 28/ 9/2021 7: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 28 15.02 0 0 0.00 / 649.51 2 2
2 7 2004.32 42 14.19 3093 1843 1.84 / 651.35 2 2
3 13 1600.96 19 14.24 2545 689 2.53 / 652.04 2 2
4 13 1031.68 19 14.40 1808 495 3.03 / 652.53 2 5
5 13 475.00 19 14.66 1056 294 3.32 / 652.83 2 2
6 13 91.24 19 14.90 454 129 3.45 / 652.96 2 2
7 8 0.08 175 14.90 315 821 4.27 / 653.78 2 3
Average= 4.25
(KJ/cycle)

Cycle 152 GMT 18/ 9/2021 7:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 28 15.01 0 0 0.00 / 645.20 2 2
2 7 2007.16 42 14.20 3060 1825 1.82 / 647.02 2 2
3 13 1740.60 19 14.20 2754 743 2.57 / 647.77 2 2
4 13 1026.64 19 14.42 1803 494 3.06 / 648.26 2 7
5 13 461.72 19 14.68 1046 292 3.35 / 648.55 2 2
6 13 84.84 19 14.91 449 127 3.48 / 648.68 2 2
7 8 0.12 175 14.90 317 827 4.31 / 649.51 2 3
Average= 4.25
(KJ/cycle)

Cycle 151 GMT 8/ 9/2021 7:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 28 15.01 0 0 0.00 / 640.78 2 2
2 7 2006.52 42 14.19 3076 1833 1.83 / 642.61 2 2
3 13 1743.92 19 14.20 2749 742 2.57 / 643.35 2 2
4 13 1158.00 19 14.36 1972 538 3.11 / 643.89 2 2
5 13 572.80 19 14.61 1189 330 3.44 / 644.22 2 7
6 13 136.80 19 14.88 528 149 3.59 / 644.37 2 2
7 8 0.04 175 14.89 319 831 4.42 / 645.20 2 2
Average= 4.24
(KJ/cycle)

Cycle 150 GMT 29/ 8/2021 8: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 28 15.01 0 0 0.00 / 636.48 2 2
2 7 2009.12 43 14.20 3049 1862 1.86 / 638.34 2 2
3 13 1593.12 19 14.24 2548 689 2.55 / 639.03 2 3
4 13 1042.28 19 14.40 1829 500 3.05 / 639.53 2 6
5 13 478.96 19 14.66 1074 299 3.35 / 639.83 2 2
6 13 43.24 19 14.93 384 109 3.46 / 639.94 2 2
7 8 0.00 175 14.89 321 836 4.30 / 640.78 2 2
Average= 4.24
(KJ/cycle)

Cycle 149 GMT 19/ 8/2021 8:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 28 15.02 0 0 0.00 / 632.09 2 2
2 7 2002.80 42 14.20 3054 1821 1.82 / 633.91 2 2
3 13 1723.36 19 14.22 2700 729 2.55 / 634.64 2 2
4 13 1014.60 19 14.42 1783 489 3.04 / 635.13 2 2
5 13 448.32 19 14.68 1021 285 3.32 / 635.41 2 3
6 13 92.52 19 14.91 454 129 3.45 / 635.54 2 2
7 13 55.12 19 14.92 391 111 3.56 / 635.65 2 2
8 8 0.08 175 14.89 317 826 4.39 / 636.48 2 2
Average= 4.24
(KJ/cycle)

Cycle 148 GMT 9/ 8/2021 8:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 28 15.02 0 0 0.00 / 627.87 2 2
2 7 2010.68 42 14.20 3075 1834 1.83 / 629.70 2 2
3 13 1614.44 19 14.25 2553 691 2.53 / 630.39 2 2
4 13 1056.20 19 14.40 1844 505 3.03 / 630.90 2 5
5 13 363.40 19 14.74 894 250 3.28 / 631.15 2 2
6 13 57.44 19 14.93 397 113 3.39 / 631.26 2 2
7 8 0.12 175 14.90 319 832 4.22 / 632.09 2 3
Average= 4.24
(KJ/cycle)

Cycle 147 GMT 30/ 7/2021 8:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 28 15.01 0 0 0.00 / 623.63 2 2
2 7 2002.92 42 14.20 3068 1830 1.83 / 625.46 2 2
3 13 1589.68 19 14.26 2538 688 2.52 / 626.14 2 2
4 13 1015.16 19 14.42 1782 488 3.01 / 626.63 2 2
5 13 468.76 19 14.67 1049 292 3.30 / 626.93 2 2
6 13 44.40 19 14.94 383 109 3.41 / 627.03 2 2
7 8 -0.08 175 14.91 319 832 4.24 / 627.87 2 2
Average= 4.24
(KJ/cycle)

Cycle 146 GMT 20/ 7/2021 8:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 28 15.01 0 0 0.00 / 619.33 2 2
2 7 2009.60 42 14.20 3083 1839 1.84 / 621.17 2 2
3 13 1601.32 19 14.25 2549 690 2.53 / 621.86 2 2
4 13 1050.16 19 14.41 1832 502 3.03 / 622.36 2 3
5 13 484.36 19 14.67 1070 298 3.33 / 622.66 2 3
6 13 86.48 19 14.91 451 128 3.46 / 622.79 2 2
7 8 0.16 175 14.90 321 837 4.29 / 623.63 2 3
Average= 4.24
(KJ/cycle)

Cycle 145 GMT 10/ 7/2021 9: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 28 15.02 0 0 0.00 / 615.12 2 2
2 7 2011.44 43 14.20 3057 1867 1.87 / 616.99 2 2
3 13 1484.44 19 14.29 2399 651 2.52 / 617.64 2 2
4 13 1072.48 19 14.40 1851 506 3.02 / 618.15 2 2
5 13 366.20 19 14.74 896 251 3.28 / 618.40 2 2
6 13 57.88 19 14.93 402 114 3.39 / 618.51 2 2
7 8 0.00 175 14.91 315 822 4.21 / 619.33 2 2
Average= 4.24
(KJ/cycle)

Cycle 144 GMT 30/ 6/2021 9:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 28 15.02 0 0 0.00 / 610.67 2 2
2 7 2006.00 42 14.20 3090 1843 1.84 / 612.51 2 2
3 13 1875.48 19 14.18 2918 786 2.63 / 613.30 2 2
4 13 1134.20 19 14.39 1902 520 3.15 / 613.82 2 3
5 13 571.00 19 14.63 1192 331 3.48 / 614.15 2 3
6 13 131.44 19 14.89 522 148 3.63 / 614.30 2 2
7 8 0.20 175 14.91 317 827 4.46 / 615.12 2 2
Average= 4.24
(KJ/cycle)

Cycle 143 GMT 20/ 6/2021 9:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 28 15.02 0 0 0.00 / 606.26 2 2
2 7 2006.52 42 14.20 3068 1830 1.83 / 608.09 2 2
3 13 1734.64 19 14.21 2736 739 2.57 / 608.83 2 2
4 13 1159.28 19 14.37 1974 539 3.11 / 609.37 2 4
5 13 580.04 19 14.62 1206 335 3.44 / 609.71 2 3
6 13 71.96 19 14.93 433 123 3.57 / 609.83 2 2
7 8 0.04 175 14.91 321 838 4.40 / 610.67 2 2
Average= 4.24
(KJ/cycle)

Cycle 142 GMT 10/ 6/2021 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 28 15.01 0 0 0.00 / 601.94 2 2
2 7 2002.48 42 14.20 3081 1838 1.84 / 603.78 2 2
3 13 1724.08 19 14.22 2732 738 2.58 / 604.52 2 2
4 13 1130.96 19 14.39 1922 525 3.10 / 605.04 2 6
5 13 434.60 19 14.71 1010 282 3.38 / 605.32 2 2
6 13 73.24 19 14.93 423 120 3.50 / 605.44 2 2
7 8 0.04 175 14.91 314 819 4.32 / 606.26 2 2
Average= 4.24
(KJ/cycle)

Cycle 141 GMT 31/ 5/2021 9:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 28 15.03 0 0 0.00 / 597.66 2 2
2 7 2002.56 42 14.21 3064 1829 1.83 / 599.49 2 2
3 13 1730.44 19 14.23 2715 734 2.56 / 600.22 2 2
4 13 1013.20 19 14.44 1780 488 3.05 / 600.71 2 6
5 13 456.80 19 14.69 1037 289 3.34 / 601.00 2 2
6 13 77.24 19 14.93 432 123 3.46 / 601.12 2 2
7 8 0.08 175 14.91 315 822 4.28 / 601.94 2 3
Average= 4.24
(KJ/cycle)

Cycle 140 GMT 21/ 5/2021 10: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 28 15.02 0 0 0.00 / 593.33 2 2
2 7 2007.92 43 14.20 3067 1873 1.87 / 595.20 2 2
3 13 1728.12 19 14.22 2721 735 2.61 / 595.94 2 2
4 13 1022.64 19 14.44 1783 489 3.10 / 596.43 2 7
5 13 467.24 19 14.69 1050 293 3.39 / 596.72 2 2
6 13 48.60 19 14.95 389 110 3.50 / 596.83 2 2
7 8 0.00 175 14.92 317 828 4.33 / 597.66 2 2
Average= 4.24
(KJ/cycle)

Cycle 139 GMT 11/ 5/2021 10:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 28 15.03 0 0 0.00 / 589.05 2 2
2 7 2004.16 42 14.20 3083 1839 1.84 / 590.89 2 2
3 13 1598.28 19 14.26 2534 687 2.53 / 591.57 2 2
4 13 1032.20 19 14.42 1818 498 3.02 / 592.07 2 7
5 13 479.72 19 14.68 1071 299 3.32 / 592.37 2 2
6 13 90.40 19 14.91 456 129 3.45 / 592.50 2 2
7 8 0.08 175 14.91 318 830 4.28 / 593.33 2 3
Average= 4.24
(KJ/cycle)

Cycle 138 GMT 1/ 5/2021 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 28 15.01 0 0 0.00 / 584.75 2 2
2 7 2002.28 42 14.21 3063 1828 1.83 / 586.58 2 2
3 13 1722.36 19 14.23 2728 738 2.57 / 587.31 2 2
4 13 1131.76 19 14.39 1935 529 3.09 / 587.84 2 4
5 13 428.00 19 14.72 984 275 3.37 / 588.12 2 3
6 13 70.44 19 14.94 417 118 3.49 / 588.24 2 2
7 8 0.04 175 14.92 311 812 4.30 / 589.05 2 2
Average= 4.24
(KJ/cycle)

Cycle 137 GMT 21/ 4/2021 11: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 28 15.02 0 0 0.00 / 580.39 2 2
2 7 2008.60 42 14.22 3030 1810 1.81 / 582.20 2 2
3 13 1740.96 19 14.23 2729 738 2.55 / 582.94 2 2
4 13 1163.16 19 14.38 1975 540 3.09 / 583.48 2 3
5 13 573.68 19 14.63 1191 331 3.42 / 583.81 2 3
6 13 65.00 19 14.93 410 116 3.53 / 583.93 2 2
7 8 0.08 175 14.91 315 822 4.36 / 584.75 2 2
Average= 4.24
(KJ/cycle)

Cycle 136 GMT 11/ 4/2021 11:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 28 15.01 0 0 0.00 / 576.03 2 2
2 7 2004.20 42 14.21 3064 1829 1.83 / 577.86 2 2
3 13 1732.96 19 14.23 2732 739 2.57 / 578.59 2 2
4 13 1023.96 19 14.45 1788 491 3.06 / 579.08 2 6
5 13 599.72 19 14.62 1228 341 3.40 / 579.43 2 6
6 13 66.68 19 14.93 423 120 3.52 / 579.55 2 2
7 8 0.08 175 14.90 324 845 4.36 / 580.39 2 2
Average= 4.24
(KJ/cycle)

Cycle 135 GMT 1/ 4/2021 11:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 29 15.01 0 0 0.00 / 571.70 2 2
2 7 2008.68 42 14.20 3088 1842 1.84 / 573.54 2 2
3 13 1472.20 19 14.31 2380 647 2.49 / 574.18 2 3
4 13 1194.48 19 14.36 2008 548 3.04 / 574.73 2 2
5 13 598.08 19 14.62 1224 340 3.38 / 575.07 2 6
6 13 34.76 19 14.93 380 108 3.48 / 575.18 2 2
7 8 0.00 175 14.89 325 847 4.33 / 576.03 2 2
Average= 4.24
(KJ/cycle)

Cycle 134 GMT 22/ 3/2021 12: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 29 15.03 0 0 0.00 / 567.41 2 2
2 7 2006.88 42 14.22 3043 1817 1.82 / 569.23 2 2
3 13 1613.56 19 14.27 2560 694 2.51 / 569.92 2 2
4 13 1070.04 19 14.42 1855 508 3.02 / 570.43 2 3
5 13 508.96 19 14.67 1103 307 3.33 / 570.74 2 7
6 13 51.44 19 14.94 402 114 3.44 / 570.85 2 2
7 8 0.20 175 14.91 323 843 4.28 / 571.70 2 2
Average= 4.23
(KJ/cycle)

Cycle 133 GMT 12/ 3/2021 12:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 29 15.02 0 0 0.00 / 563.20 2 2
2 7 2002.56 42 14.21 3077 1836 1.84 / 565.04 2 2
3 13 1599.40 19 14.28 2536 688 2.52 / 565.72 2 3
4 13 1056.32 19 14.43 1837 504 3.03 / 566.23 2 2
5 13 376.52 19 14.76 910 255 3.28 / 566.48 2 2
6 13 58.52 19 14.95 400 114 3.40 / 566.60 2 2
7 8 0.20 175 14.92 312 815 4.21 / 567.41 2 2
Average= 4.23
(KJ/cycle)

Cycle 132 GMT 2/ 3/2021 12:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 29 15.03 0 0 0.00 / 558.93 2 2
2 7 2002.92 42 14.22 3054 1824 1.82 / 560.75 2 2
3 13 1596.56 19 14.29 2531 687 2.51 / 561.44 2 2
4 13 1039.64 19 14.44 1828 502 3.01 / 561.94 2 2
5 13 473.08 19 14.70 1058 295 3.31 / 562.24 2 3
6 13 82.80 19 14.92 447 127 3.43 / 562.36 2 2
7 8 0.00 175 14.91 321 838 4.27 / 563.20 2 3
Average= 4.23
(KJ/cycle)

Cycle 131 GMT 20/ 2/2021 12:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 29 15.04 0 0 0.00 / 554.69 2 2
2 7 2004.04 42 14.22 3060 1828 1.83 / 556.52 2 2
3 13 1589.12 19 14.28 2550 692 2.52 / 557.21 2 2
4 13 1018.12 19 14.46 1781 489 3.01 / 557.70 2 3
5 13 440.96 19 14.72 1014 284 3.29 / 557.99 2 3
6 13 38.08 19 14.95 377 107 3.40 / 558.09 2 2
7 8 0.04 175 14.92 319 833 4.23 / 558.93 2 2
Average= 4.23
(KJ/cycle)

Cycle 130 GMT 10/ 2/2021 13: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 29 15.03 0 0 0.00 / 550.45 2 2
2 7 2003.96 42 14.23 3055 1826 1.83 / 552.28 2 2
3 13 1731.92 19 14.25 2734 740 2.57 / 553.02 2 3
4 13 1021.20 19 14.46 1805 496 3.06 / 553.52 2 5
5 13 327.12 19 14.80 838 236 3.30 / 553.75 2 2
6 13 45.24 19 14.96 389 111 3.41 / 553.86 2 2
7 8 0.16 175 14.93 319 833 4.24 / 554.69 2 2
Average= 4.23
(KJ/cycle)

Cycle 129 GMT 31/ 1/2021 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 29 15.03 0 0 0.00 / 546.05 2 2
2 7 2008.24 42 14.21 3088 1843 1.84 / 547.90 2 2
3 13 1879.40 19 14.20 2948 795 2.64 / 548.69 2 2
4 13 1136.84 19 14.41 1942 532 3.17 / 549.22 2 3
5 13 433.52 19 14.73 1006 282 3.45 / 549.50 2 2
6 13 34.08 19 14.96 369 105 3.56 / 549.61 2 2
7 8 0.08 175 14.92 323 843 4.40 / 550.45 2 2
Average= 4.23
(KJ/cycle)

Cycle 128 GMT 21/ 1/2021 13:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 29 15.03 0 0 0.00 / 541.64 2 2
2 7 2006.52 42 14.22 3062 1829 1.83 / 543.47 2 2
3 13 1875.32 19 14.20 2936 792 2.62 / 544.26 2 2
4 13 1116.56 19 14.42 1919 526 3.15 / 544.79 2 3
5 13 542.52 19 14.67 1154 322 3.47 / 545.11 2 7
6 13 60.68 19 14.95 414 118 3.59 / 545.23 2 2
7 8 0.00 175 14.92 317 828 4.41 / 546.05 2 2
Average= 4.23
(KJ/cycle)

Cycle 127 GMT 11/ 1/2021 14:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 29 15.03 0 0 0.00 / 537.31 2 2
2 7 2003.60 42 14.22 3080 1839 1.84 / 539.15 2 2
3 13 1745.36 19 14.25 2759 747 2.59 / 539.89 2 2
4 13 1021.00 19 14.47 1800 495 3.08 / 540.39 2 4
5 13 463.72 19 14.71 1054 295 3.38 / 540.68 2 4
6 13 44.28 19 14.96 394 112 3.49 / 540.80 2 2
7 8 0.12 175 14.93 323 844 4.33 / 541.64 2 2
Average= 4.23
(KJ/cycle)

Cycle 126 GMT 1/ 1/2021 14:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 29 15.03 0 0 0.00 / 532.98 2 2
2 7 2004.04 43 14.22 3046 1863 1.86 / 534.84 2 2
3 13 1736.20 19 14.24 2742 742 2.60 / 535.58 2 2
4 13 1010.20 19 14.47 1788 492 3.10 / 536.08 2 3
5 13 439.44 19 14.73 1016 284 3.38 / 536.36 2 5
6 13 33.92 19 14.97 367 104 3.48 / 536.46 2 2
7 8 0.04 175 14.92 323 843 4.33 / 537.31 2 3
Average= 4.23
(KJ/cycle)

Cycle 125 GMT 22/12/2020 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 29 15.04 0 0 0.00 / 528.73 2 2
2 7 2003.64 42 14.22 3064 1830 1.83 / 530.56 2 2
3 13 1592.56 19 14.30 2527 687 2.52 / 531.25 2 3
4 13 1028.84 19 14.46 1802 495 3.01 / 531.74 2 3
5 13 454.48 19 14.72 1025 287 3.30 / 532.03 2 5
6 13 36.00 19 14.97 376 107 3.41 / 532.14 2 2
7 8 0.20 175 14.92 323 843 4.25 / 532.98 2 4
Average= 4.23
(KJ/cycle)

Cycle 124 GMT 12/12/2020 15:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 28 15.02 0 0 0.00 / 524.56 2 2
2 7 2003.72 43 14.23 3037 1858 1.86 / 526.42 2 2
3 13 1473.92 19 14.33 2393 652 2.51 / 527.07 2 2
4 13 1052.60 19 14.46 1831 503 3.01 / 527.58 2 7
5 13 355.32 19 14.79 874 246 3.26 / 527.82 2 2
6 13 23.04 19 14.98 343 98 3.36 / 527.92 2 2
7 8 0.16 175 14.93 311 813 4.17 / 528.73 2 3
Average= 4.23
(KJ/cycle)

Cycle 123 GMT 2/12/2020 15:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 29 15.04 0 0 0.00 / 520.22 2 2
2 7 2002.56 42 14.23 3051 1823 1.82 / 522.04 2 2
3 13 1488.24 19 14.33 2392 651 2.47 / 522.69 2 2
4 13 1208.20 19 14.39 2033 556 3.03 / 523.25 2 3
5 13 615.84 19 14.64 1242 345 3.38 / 523.59 2 4
6 13 75.64 19 14.94 438 124 3.50 / 523.72 2 2
7 8 0.08 175 14.92 323 843 4.34 / 524.56 2 2
Average= 4.23
(KJ/cycle)

Cycle 122 GMT 22/11/2020 16: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 29 15.04 0 0 0.00 / 515.90 2 2
2 7 2002.28 42 14.23 3068 1834 1.83 / 517.74 2 2
3 13 1738.72 19 14.26 2727 739 2.57 / 518.47 2 2
4 13 1037.56 19 14.47 1822 501 3.07 / 518.98 2 3
5 13 484.36 19 14.72 1069 299 3.37 / 519.27 2 2
6 13 19.52 19 14.98 354 101 3.47 / 519.37 2 2
7 8 0.00 175 14.93 323 844 4.32 / 520.22 2 2
Average= 4.23
(KJ/cycle)

Cycle 121 GMT 12/11/2020 16:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 29 15.04 0 0 0.00 / 511.48 2 2
2 7 2003.04 42 14.23 3059 1828 1.83 / 513.30 2 2
3 13 1735.08 19 14.27 2736 742 2.57 / 514.05 2 2
4 13 1148.76 19 14.42 1971 540 3.11 / 514.59 2 3
5 13 575.76 19 14.67 1202 335 3.45 / 514.92 2 3
6 13 60.12 19 14.96 427 121 3.57 / 515.04 2 2
7 8 0.04 175 14.93 329 860 4.43 / 515.90 2 4
Average= 4.23
(KJ/cycle)

Cycle 120 GMT 2/11/2020 16:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 28 15.03 0 0 0.00 / 507.21 2 2
2 7 2002.92 43 14.22 3075 1880 1.88 / 509.09 2 2
3 13 1590.48 19 14.30 2548 692 2.57 / 509.78 2 3
4 13 1045.80 19 14.47 1841 506 3.08 / 510.29 2 4
5 13 333.40 19 14.82 847 238 3.32 / 510.53 2 3
6 13 21.56 19 14.98 354 101 3.42 / 510.63 2 2
7 8 0.20 175 14.94 324 847 4.27 / 511.48 2 2
Average= 4.23
(KJ/cycle)

Cycle 119 GMT 23/10/2020 17: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 28 15.04 0 0 0.00 / 502.88 2 2
2 7 2003.60 42 14.23 3068 1834 1.83 / 504.71 2 2
3 13 1598.80 19 14.31 2556 695 2.53 / 505.41 2 2
4 13 1178.20 19 14.41 1990 545 3.07 / 505.95 2 4
5 13 455.44 19 14.74 1032 289 3.36 / 506.24 2 2
6 13 35.48 19 14.98 379 108 3.47 / 506.35 2 2
7 8 0.08 175 14.93 330 862 4.33 / 507.21 2 2
Average= 4.23
(KJ/cycle)

Cycle 118 GMT 13/10/2020 17:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 28 15.03 0 0 0.00 / 498.69 2 2
2 7 2002.80 42 14.24 3051 1825 1.82 / 500.52 2 2
3 13 1581.92 19 14.31 2526 687 2.51 / 501.20 2 2
4 13 1019.48 19 14.49 1781 490 3.00 / 501.69 2 3
5 13 587.16 19 14.67 1207 336 3.34 / 502.03 2 7
6 8 0.16 175 14.93 325 849 4.19 / 502.88 2 3
Average= 4.23
(KJ/cycle)

Cycle 117 GMT 3/10/2020 17:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 28 15.03 0 0 0.00 / 494.36 2 2
2 7 2010.56 42 14.23 3059 1828 1.83 / 496.19 2 2
3 13 1614.08 19 14.29 2582 701 2.53 / 496.89 2 2
4 13 1181.84 19 14.41 2001 548 3.08 / 497.44 2 4
5 13 457.08 19 14.73 1035 290 3.37 / 497.73 2 4
6 13 17.92 19 14.98 357 102 3.47 / 497.83 2 2
7 8 0.08 175 14.93 329 860 4.33 / 498.69 2 3
Average= 4.23
(KJ/cycle)

Cycle 116 GMT 23/ 9/2020 17:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 28 15.05 0 0 0.00 / 490.05 2 2
2 7 2004.52 42 14.23 3076 1838 1.84 / 491.89 2 2
3 13 1593.12 19 14.31 2540 691 2.53 / 492.58 2 2
4 13 1159.76 19 14.43 1958 537 3.07 / 493.11 2 5
5 13 442.48 19 14.75 1014 284 3.35 / 493.40 2 3
6 13 16.12 19 14.98 356 101 3.45 / 493.50 2 2
7 8 0.08 175 14.92 331 864 4.32 / 494.36 2 2
Average= 4.23
(KJ/cycle)

Cycle 115 GMT 13/ 9/2020 17:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 28 15.05 0 0 0.00 / 485.87 2 2
2 7 2003.72 42 14.23 3071 1835 1.84 / 487.71 2 2
3 13 1593.16 19 14.32 2545 692 2.53 / 488.40 2 2
4 13 1037.48 19 14.48 1806 497 3.02 / 488.90 2 3
5 13 466.16 19 14.73 1052 294 3.32 / 489.19 2 2
6 8 0.16 175 14.95 327 856 4.17 / 490.05 2 3
Average= 4.22
(KJ/cycle)

Cycle 114 GMT 3/ 9/2020 18:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 28 15.05 0 0 0.00 / 481.76 2 2
2 7 2003.92 42 14.23 3076 1838 1.84 / 483.60 2 2
3 13 1475.96 19 14.36 2385 651 2.49 / 484.25 2 2
4 13 1059.44 19 14.47 1848 508 3.00 / 484.76 2 8
5 13 372.24 19 14.80 903 254 3.25 / 485.01 2 3
6 8 0.16 175 14.95 328 858 4.11 / 485.87 2 3
Average= 4.22
(KJ/cycle)

Cycle 113 GMT 24/ 8/2020 18:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 28 15.05 0 0 0.00 / 477.53 2 2
2 7 2002.64 42 14.24 3073 1838 1.84 / 479.37 2 2
3 13 1734.00 19 14.27 2726 739 2.58 / 480.11 2 2
4 13 1031.48 19 14.49 1807 497 3.07 / 480.61 2 5
5 13 469.64 19 14.74 1046 293 3.37 / 480.90 2 3
6 8 0.08 175 14.95 329 861 4.23 / 481.76 2 3
Average= 4.23
(KJ/cycle)

Cycle 112 GMT 14/ 8/2020 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 27 15.05 0 0 0.00 / 473.33 2 2
2 3 1045.00 1 15.44 0 0 0.00 / 473.33 2 2
3 7 2008.08 42 14.24 3060 1830 1.83 / 475.16 2 2
4 13 1746.20 19 14.27 2747 745 2.57 / 475.90 2 2
5 13 1023.12 19 14.50 1798 495 3.07 / 476.40 2 6
6 13 460.64 19 14.75 1032 289 3.36 / 476.69 2 4
7 8 0.08 175 14.96 323 846 4.21 / 477.53 2 3
Average= 4.23
(KJ/cycle)

Cycle 111 GMT 4/ 8/2020 19:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 28 15.05 0 0 0.00 / 469.09 2 2
2 3 969.44 -1 15.45 0 0 0.00 / 469.09 2 2
3 7 2007.52 42 14.24 3062 1831 1.83 / 470.92 2 2
4 13 1731.80 19 14.27 2732 741 2.57 / 471.66 2 2
5 13 1147.16 19 14.45 1949 535 3.11 / 472.19 2 2
6 13 436.60 19 14.76 1008 283 3.39 / 472.48 2 2
7 8 0.00 175 14.95 326 853 4.24 / 473.33 2 2
Average= 4.23
(KJ/cycle)

Cycle 110 GMT 25/ 7/2020 19:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 28 15.06 0 0 0.00 / 464.87 2 2
2 7 2009.08 42 14.25 3049 1825 1.82 / 466.69 2 2
3 13 1600.12 19 14.32 2532 689 2.51 / 467.38 2 2
4 13 1183.08 19 14.43 2003 549 3.06 / 467.93 2 4
5 13 465.00 19 14.75 1045 293 3.36 / 468.23 2 3
6 8 0.20 175 14.96 329 861 4.22 / 469.09 2 2
Average= 4.23
(KJ/cycle)

Cycle 109 GMT 15/ 7/2020 19:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 28 15.05 0 0 0.00 / 460.68 2 2
2 7 2008.48 42 14.23 3077 1839 1.84 / 462.52 2 2
3 13 1741.68 19 14.28 2731 741 2.58 / 463.26 2 2
4 13 1035.88 19 14.50 1808 498 3.08 / 463.76 2 6
5 13 349.40 19 14.82 880 248 3.33 / 464.00 2 3
6 8 0.12 175 14.96 331 867 4.19 / 464.87 2 3
Average= 4.23
(KJ/cycle)

Cycle 108 GMT 5/ 7/2020 20: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 28 15.05 0 0 0.00 / 456.46 2 2
2 7 2004.80 42 14.25 3031 1814 1.81 / 458.28 2 2
3 13 1604.56 19 14.32 2544 692 2.51 / 458.97 2 2
4 13 1042.60 19 14.50 1814 500 3.01 / 459.47 2 5
5 13 612.80 19 14.67 1247 348 3.35 / 459.82 2 3
6 8 0.12 175 14.96 329 861 4.21 / 460.68 2 2
Average= 4.23
(KJ/cycle)

Cycle 107 GMT 25/ 6/2020 20:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 28 15.05 0 0 0.00 / 452.16 2 2
2 7 2002.00 42 14.24 3061 1831 1.83 / 453.99 2 2
3 13 1597.12 19 14.32 2546 693 2.52 / 454.68 2 2
4 13 1162.48 19 14.43 1981 543 3.07 / 455.22 2 3
5 13 422.80 19 14.77 988 277 3.34 / 455.50 2 2
6 13 28.48 19 14.99 363 103 3.45 / 455.60 2 2
7 8 -0.04 175 14.94 329 860 4.31 / 456.46 2 3
Average= 4.23
(KJ/cycle)

Cycle 106 GMT 15/ 6/2020 20:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 28 15.05 0 0 0.00 / 447.78 2 2
2 7 2003.92 42 14.24 3049 1824 1.82 / 449.60 2 2
3 13 1741.72 19 14.28 2746 745 2.57 / 450.34 2 2
4 13 1160.00 19 14.46 1965 540 3.11 / 450.88 2 3
5 13 441.76 19 14.77 1016 285 3.39 / 451.17 2 4
6 13 73.20 19 14.98 439 125 3.52 / 451.29 2 2
7 8 0.04 175 14.95 329 861 4.38 / 452.16 2 2
Average= 4.23
(KJ/cycle)

Cycle 105 GMT 5/ 6/2020 21:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 28 15.06 0 0 0.00 / 443.45 2 2
2 7 2010.64 42 14.24 3055 1827 1.83 / 445.27 2 2
3 13 1745.32 19 14.28 2743 744 2.57 / 446.02 2 2
4 13 1031.28 19 14.50 1805 497 3.07 / 446.52 2 4
5 13 469.44 19 14.75 1056 296 3.36 / 446.81 2 4
6 13 38.08 19 14.99 384 109 3.47 / 446.92 2 2
7 8 0.00 175 14.95 327 856 4.33 / 447.78 2 3
Average= 4.22
(KJ/cycle)

Cycle 104 GMT 26/ 5/2020 21:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 28 15.06 0 0 0.00 / 439.22 2 2
2 7 2004.96 42 14.25 3047 1824 1.82 / 441.05 2 2
3 13 1603.40 19 14.34 2530 689 2.51 / 441.74 2 2
4 13 1044.64 19 14.50 1822 502 3.01 / 442.24 2 4
5 13 344.76 19 14.83 862 243 3.26 / 442.48 2 2
6 13 46.68 19 15.00 391 111 3.37 / 442.59 2 2
7 8 0.04 175 14.95 326 853 4.22 / 443.45 2 2
Average= 4.22
(KJ/cycle)

Cycle 103 GMT 16/ 5/2020 21:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 28 15.06 0 0 0.00 / 435.00 2 2
2 7 2002.36 42 14.25 3057 1830 1.83 / 436.83 2 2
3 13 1600.08 19 14.33 2551 695 2.52 / 437.53 2 2
4 13 1038.24 19 14.51 1814 500 3.02 / 438.03 2 6
5 13 345.00 19 14.83 861 243 3.27 / 438.27 2 2
6 13 44.96 19 15.00 385 110 3.38 / 438.38 2 2
7 8 -0.08 175 14.96 323 846 4.22 / 439.22 2 2
Average= 4.22
(KJ/cycle)

Cycle 102 GMT 6/ 5/2020 22:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 28 15.06 0 0 0.00 / 430.71 2 2
2 7 2004.52 42 14.25 3050 1825 1.83 / 432.53 2 2
3 13 1744.24 19 14.29 2744 745 2.57 / 433.28 2 2
4 13 1039.24 19 14.50 1829 504 3.07 / 433.78 2 4
5 13 368.12 19 14.82 898 253 3.33 / 434.04 2 2
6 13 53.92 19 15.00 404 115 3.44 / 434.15 2 2
7 8 0.16 175 14.96 325 851 4.29 / 435.00 2 2
Average= 4.22
(KJ/cycle)

Cycle 101 GMT 26/ 4/2020 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 29 15.07 0 0 0.00 / 426.44 2 2
2 7 2010.72 42 14.25 3052 1827 1.83 / 428.27 2 2
3 13 1596.40 19 14.34 2542 693 2.52 / 428.96 2 3
4 13 1046.00 19 14.50 1830 504 3.02 / 429.46 2 3
5 13 473.24 19 14.76 1056 296 3.32 / 429.76 2 3
6 13 43.80 19 15.00 385 110 3.43 / 429.87 2 2
7 8 0.04 175 14.96 321 840 4.27 / 430.71 2 3
Average= 4.22
(KJ/cycle)

Cycle 100 GMT 16/ 4/2020 22:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 28 15.06 0 0 0.00 / 422.20 2 2
2 7 2006.92 43 14.25 3032 1858 1.86 / 424.06 2 2
3 13 1602.80 19 14.34 2538 692 2.55 / 424.75 2 2
4 13 1040.52 19 14.51 1824 503 3.05 / 425.25 2 2
5 13 350.24 19 14.84 870 245 3.30 / 425.50 2 3
6 13 50.84 19 15.00 395 113 3.41 / 425.61 2 2
7 8 0.12 175 14.97 317 830 4.24 / 426.44 2 2
Average= 4.22
(KJ/cycle)

Cycle 99 GMT 6/ 4/2020 22:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 28 15.08 0 0 0.00 / 417.91 2 2
2 7 2009.32 42 14.24 3081 1843 1.84 / 419.76 2 2
3 13 1605.68 19 14.34 2553 696 2.54 / 420.45 2 2
4 13 1038.36 19 14.51 1824 503 3.04 / 420.95 2 6
5 13 464.84 19 14.76 1046 293 3.33 / 421.25 2 2
6 13 37.36 19 15.00 381 109 3.44 / 421.36 2 2
7 8 -0.04 175 14.96 322 843 4.29 / 422.20 2 2
Average= 4.22
(KJ/cycle)

Cycle 98 GMT 27/ 3/2020 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 28 15.08 0 0 0.00 / 413.72 2 2
2 7 2005.04 43 14.24 3069 1879 1.88 / 415.60 2 2
3 13 1585.88 19 14.34 2530 689 2.57 / 416.29 2 2
4 13 1033.20 19 14.51 1811 499 3.07 / 416.79 2 4
5 13 453.44 19 14.77 1033 290 3.36 / 417.08 2 5
6 8 0.04 175 14.98 319 836 4.19 / 417.91 2 2
Average= 4.22
(KJ/cycle)

Cycle 97 GMT 17/ 3/2020 23:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 28 15.07 0 0 0.00 / 409.33 2 2
2 7 2005.60 42 14.25 3066 1835 1.84 / 411.17 2 2
3 13 1738.88 19 14.29 2723 739 2.57 / 411.91 2 2
4 13 1154.28 19 14.47 1957 538 3.11 / 412.44 2 4
5 13 574.36 19 14.71 1186 331 3.44 / 412.78 2 2
6 13 59.52 19 15.00 407 116 3.56 / 412.89 2 2
7 8 0.04 175 14.97 316 828 4.39 / 413.72 2 3
Average= 4.22
(KJ/cycle)

Cycle 96 GMT 7/ 3/2020 23:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 28 15.07 0 0 0.00 / 405.02 2 2
2 7 2008.20 43 14.25 3073 1883 1.88 / 406.91 2 2
3 13 1597.12 19 14.35 2525 688 2.57 / 407.60 2 2
4 13 1032.60 19 14.52 1797 496 3.07 / 408.09 2 5
5 13 461.48 19 14.77 1032 290 3.36 / 408.38 2 2
6 13 38.56 19 15.01 376 107 3.46 / 408.49 2 2
7 8 0.08 175 14.97 322 844 4.31 / 409.33 2 2
Average= 4.22
(KJ/cycle)

Cycle 95 GMT 26/ 2/2020 23:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 28 15.08 0 0 0.00 / 400.71 2 2
2 7 2005.68 43 14.25 3067 1879 1.88 / 402.59 2 2
3 13 1582.40 19 14.35 2512 685 2.56 / 403.28 2 3
4 13 1021.76 19 14.52 1803 497 3.06 / 403.78 2 4
5 13 442.12 19 14.78 1012 284 3.35 / 404.06 2 4
6 13 65.60 19 15.00 429 122 3.47 / 404.18 2 2
7 8 -0.04 175 14.97 321 841 4.31 / 405.02 2 3
Average= 4.22
(KJ/cycle)

Cycle 94 GMT 17/ 2/2020 0:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 28 15.07 0 0 0.00 / 396.42 2 2
2 7 2002.12 42 14.26 3064 1835 1.84 / 398.25 2 2
3 13 1588.44 19 14.35 2537 692 2.53 / 398.94 2 3
4 13 1043.00 19 14.52 1834 506 3.03 / 399.45 2 3
5 13 482.56 19 14.77 1069 300 3.33 / 399.75 2 2
6 13 42.12 19 15.01 394 112 3.45 / 399.86 2 2
7 8 0.08 175 14.97 325 851 4.30 / 400.71 2 3
Average= 4.22
(KJ/cycle)

Cycle 93 GMT 7/ 2/2020 0:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 28 15.08 0 0 0.00 / 392.04 2 2
2 7 2006.40 43 14.26 3050 1870 1.87 / 393.91 2 2
3 13 1599.28 19 14.35 2537 692 2.56 / 394.60 2 2
4 13 1174.40 19 14.47 1976 543 3.11 / 395.15 2 5
5 13 452.32 19 14.78 1030 289 3.39 / 395.43 2 3
6 13 33.44 19 15.01 381 109 3.50 / 395.54 2 2
7 8 0.24 175 14.97 334 875 4.38 / 396.42 2 3
Average= 4.22
(KJ/cycle)

Cycle 92 GMT 28/ 1/2020 0:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 28 15.07 0 0 0.00 / 387.71 2 2
2 7 2005.08 42 14.26 3067 1837 1.84 / 389.54 2 2
3 13 1737.80 19 14.32 2699 734 2.57 / 390.28 2 2
4 13 1021.36 19 14.54 1793 495 3.07 / 390.77 2 4
5 13 451.52 19 14.78 1035 291 3.36 / 391.06 2 4
6 13 16.68 19 15.02 360 103 3.46 / 391.17 2 2
7 8 0.16 175 14.97 333 872 4.33 / 392.04 2 3
Average= 4.22
(KJ/cycle)

Cycle 91 GMT 18/ 1/2020 1:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 29 15.08 0 0 0.00 / 383.29 2 2
2 7 2006.84 42 14.26 3052 1828 1.83 / 385.12 2 2
3 13 1737.52 19 14.30 2747 746 2.57 / 385.86 2 2
4 13 1151.20 19 14.48 1968 541 3.12 / 386.41 2 3
5 13 564.96 19 14.73 1182 331 3.45 / 386.74 2 3
6 13 14.76 19 15.02 350 100 3.55 / 386.84 2 2
7 8 0.08 175 14.96 333 872 4.42 / 387.71 2 2
Average= 4.21
(KJ/cycle)

Cycle 90 GMT 8/ 1/2020 1:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 28 15.09 0 0 0.00 / 378.94 2 2
2 7 2005.32 42 14.26 3061 1833 1.83 / 380.77 2 2
3 13 1599.84 19 14.36 2533 691 2.52 / 381.46 2 2
4 13 1172.44 19 14.48 1978 544 3.07 / 382.01 2 5
5 13 569.56 19 14.73 1183 331 3.40 / 382.34 2 2
6 13 15.76 19 15.03 349 100 3.50 / 382.44 2 2
7 8 0.16 175 14.98 325 852 4.35 / 383.29 2 2
Average= 4.21
(KJ/cycle)

Cycle 89 GMT 29/12/2019 1:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 28 15.09 0 0 0.00 / 374.69 2 2
2 7 2003.48 42 14.27 3054 1830 1.83 / 376.52 2 2
3 13 1598.72 19 14.35 2573 702 2.53 / 377.22 2 2
4 13 1309.92 19 14.42 2154 590 3.12 / 377.81 2 3
5 13 435.36 19 14.81 1000 281 3.40 / 378.09 2 2
6 8 0.12 175 15.00 322 845 4.25 / 378.94 2 2
Average= 4.21
(KJ/cycle)

Cycle 88 GMT 19/12/2019 2:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 28 15.09 0 0 0.00 / 370.46 2 2
2 7 2005.00 42 14.27 3056 1832 1.83 / 372.30 2 2
3 13 1599.84 19 14.36 2548 695 2.53 / 372.99 2 2
4 13 1175.32 19 14.47 1991 547 3.07 / 373.54 2 4
5 13 447.00 19 14.80 1023 288 3.36 / 373.83 2 4
6 8 0.00 175 14.99 329 863 4.22 / 374.69 2 2
Average= 4.21
(KJ/cycle)

Cycle 87 GMT 9/12/2019 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 28 15.09 0 0 0.00 / 366.30 2 2
2 7 2006.48 42 14.26 3061 1833 1.83 / 368.13 2 2
3 13 1585.96 19 14.36 2529 690 2.52 / 368.82 2 2
4 13 1015.80 19 14.55 1793 496 3.02 / 369.32 2 3
5 13 446.08 19 14.80 1022 287 3.31 / 369.61 2 2
6 8 0.04 175 14.99 327 858 4.16 / 370.46 2 2
Average= 4.21
(KJ/cycle)

Cycle 86 GMT 29/11/2019 2:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 28 15.08 0 0 0.00 / 362.08 2 2
2 3 1020.40 1 15.48 0 0 0.00 / 362.08 2 2
3 7 2006.08 42 14.28 3043 1825 1.83 / 363.91 2 2
4 13 1722.68 19 14.32 2700 735 2.56 / 364.64 2 2
5 13 1135.04 19 14.49 1931 532 3.09 / 365.18 2 7
6 13 417.20 19 14.83 967 272 3.36 / 365.45 2 2
7 8 0.16 175 14.99 325 853 4.22 / 366.30 2 3
Average= 4.21
(KJ/cycle)

Cycle 85 GMT 19/11/2019 3: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 28 15.08 0 0 0.00 / 357.70 2 2
2 7 2003.36 42 14.28 3036 1821 1.82 / 359.52 2 2
3 13 1605.80 19 14.37 2532 691 2.51 / 360.21 2 2
4 13 1175.08 19 14.48 1988 547 3.06 / 360.75 2 2
5 13 592.32 19 14.73 1212 339 3.40 / 361.09 2 3
6 13 60.80 19 15.01 421 120 3.52 / 361.21 2 2
7 8 0.16 175 14.98 332 870 4.39 / 362.08 2 3
Average= 4.21
(KJ/cycle)

Cycle 84 GMT 9/11/2019 3:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 28 15.09 0 0 0.00 / 353.51 2 2
2 7 2004.80 42 14.27 3072 1841 1.84 / 355.35 2 2
3 13 1722.40 19 14.33 2688 732 2.57 / 356.09 2 2
4 13 1025.76 19 14.55 1797 497 3.07 / 356.58 2 4
5 13 330.72 19 14.87 851 240 3.31 / 356.82 2 2
6 8 0.04 175 14.98 333 873 4.18 / 357.70 2 3
Average= 4.21
(KJ/cycle)

Cycle 83 GMT 30/10/2019 3:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 28 15.08 0 0 0.00 / 349.38 2 2
2 7 2003.12 42 14.28 3027 1815 1.82 / 351.19 2 2
3 13 1597.40 19 14.37 2535 692 2.51 / 351.89 2 2
4 13 1042.08 19 14.54 1813 501 3.01 / 352.39 2 4
5 13 355.60 19 14.86 884 250 3.26 / 352.64 2 2
6 8 0.00 175 14.99 334 876 4.13 / 353.51 2 4
Average= 4.21
(KJ/cycle)

Cycle 82 GMT 20/10/2019 3:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 28 15.09 0 0 0.00 / 345.18 2 2
2 7 2002.52 42 14.28 3034 1820 1.82 / 347.00 2 2
3 13 1611.12 19 14.37 2561 699 2.52 / 347.70 2 2
4 13 1056.80 19 14.54 1836 507 3.03 / 348.20 2 4
5 13 492.60 19 14.79 1074 302 3.33 / 348.50 2 3
6 8 0.36 175 14.99 333 874 4.20 / 349.38 2 3
Average= 4.21
(KJ/cycle)

Cycle 81 GMT 10/10/2019 4:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 28 15.09 0 0 0.00 / 340.97 2 2
2 7 2008.80 42 14.28 3058 1834 1.83 / 342.80 2 2
3 13 1587.00 19 14.38 2520 689 2.52 / 343.49 2 2
4 13 1145.76 19 14.50 1936 533 3.06 / 344.02 2 5
5 13 429.64 19 14.83 989 279 3.33 / 344.30 2 3
6 8 -0.12 175 14.99 333 874 4.21 / 345.18 2 6
Average= 4.21
(KJ/cycle)

Cycle 80 GMT 30/ 9/2019 4:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 28 15.10 0 0 0.00 / 336.75 2 2
2 7 2003.88 42 14.27 3074 1842 1.84 / 338.60 2 2
3 13 1596.48 19 14.37 2562 700 2.54 / 339.30 2 3
4 13 1051.04 19 14.55 1827 505 3.05 / 339.80 2 6
5 13 473.80 19 14.81 1049 295 3.34 / 340.10 2 3
6 8 0.20 175 15.00 332 871 4.21 / 340.97 2 3
Average= 4.21
(KJ/cycle)

Cycle 79 GMT 20/ 9/2019 5: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 28 15.09 0 0 0.00 / 332.63 2 2
2 7 2004.36 42 14.29 3029 1818 1.82 / 334.45 2 2
3 13 1482.96 19 14.41 2397 656 2.47 / 335.11 2 2
4 13 1078.24 19 14.53 1878 518 2.99 / 335.63 2 3
5 13 374.28 19 14.87 908 257 3.25 / 335.88 2 2
6 8 -0.08 175 15.00 332 871 4.12 / 336.75 2 5
Average= 4.21
(KJ/cycle)

Cycle 78 GMT 10/ 9/2019 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 27 15.10 0 0 0.00 / 328.45 2 2
2 3 1023.04 1 15.49 0 0 0.00 / 328.45 2 2
3 7 2002.68 42 14.29 3021 1813 1.81 / 330.26 2 2
4 13 1594.84 19 14.38 2531 692 2.50 / 330.95 2 2
5 13 1034.36 19 14.56 1811 501 3.01 / 331.45 2 5
6 13 457.60 19 14.81 1034 291 3.30 / 331.74 2 4
7 8 0.12 175 14.99 340 892 4.19 / 332.63 2 3
Average= 4.21
(KJ/cycle)

Cycle 77 GMT 31/ 8/2019 5:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 28 15.09 0 0 0.00 / 324.16 2 2
2 3 946.44 -1 15.49 0 0 0.00 / 324.16 2 2
3 7 2004.08 42 14.28 3052 1830 1.83 / 325.99 2 2
4 13 1738.28 19 14.33 2740 746 2.58 / 326.74 2 2
5 13 1150.64 19 14.51 1955 539 3.12 / 327.28 2 4
6 13 443.88 19 14.83 1013 285 3.40 / 327.56 2 2
7 8 -0.08 175 15.00 337 885 4.29 / 328.45 2 3
Average= 4.21
(KJ/cycle)

Cycle 76 GMT 21/ 8/2019 5:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 28 15.10 0 0 0.00 / 319.56 2 2
2 3 1027.60 1 15.49 0 0 0.00 / 319.56 2 2
3 7 2009.84 42 14.28 3073 1843 1.84 / 321.40 2 2
4 13 1880.08 19 14.28 2928 794 2.64 / 322.19 2 2
5 13 1140.76 19 14.52 1926 531 3.17 / 322.73 2 3
6 13 296.36 19 14.91 793 225 3.39 / 322.95 2 2
7 8 0.04 175 15.00 337 885 4.28 / 323.84 2 3
8 14 0.04 65 14.95 334 325 4.60 / 324.16 2 9
Average= 4.21
(KJ/cycle)

Cycle 75 GMT 11/ 8/2019 6: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 28 15.10 0 0 0.00 / 315.28 2 2
2 7 2006.84 43 14.27 3074 1886 1.89 / 317.16 2 2
3 13 1733.40 19 14.33 2719 740 2.63 / 317.91 2 2
4 13 1015.96 19 14.57 1795 497 3.12 / 318.40 2 4
5 13 424.04 19 14.84 978 276 3.40 / 318.68 2 3
6 8 0.12 175 15.00 335 879 4.28 / 319.56 2 3
Average= 4.20
(KJ/cycle)

Cycle 74 GMT 1/ 8/2019 6:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 28 15.10 0 0 0.00 / 311.00 2 2
2 7 2008.08 42 14.29 3046 1828 1.83 / 312.83 2 2
3 13 1597.72 19 14.39 2540 694 2.52 / 313.52 2 2
4 13 1170.64 19 14.50 1971 543 3.07 / 314.06 2 2
5 13 318.72 19 14.90 821 232 3.30 / 314.30 2 2
6 13 37.36 19 15.05 386 110 3.41 / 314.41 2 2
7 8 0.20 175 15.00 332 871 4.28 / 315.28 2 4
Average= 4.20
(KJ/cycle)

Cycle 73 GMT 22/ 7/2019 6:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 28 15.10 0 0 0.00 / 306.73 2 2
2 7 2002.12 42 14.29 3046 1828 1.83 / 308.56 2 2
3 13 1738.24 19 14.34 2724 742 2.57 / 309.30 2 2
4 13 1158.52 19 14.51 1963 541 3.11 / 309.84 2 4
5 13 427.08 19 14.84 978 276 3.39 / 310.12 2 4
6 8 0.24 175 15.01 335 880 4.27 / 311.00 2 5
Average= 4.20
(KJ/cycle)

Cycle 72 GMT 12/ 7/2019 6:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 27 15.10 0 0 0.00 / 302.48 2 2
2 3 1030.04 1 15.49 0 0 0.00 / 302.48 2 2
3 7 2007.96 42 14.29 3069 1842 1.84 / 304.32 2 2
4 13 1613.28 19 14.38 2573 703 2.54 / 305.03 2 2
5 13 1068.48 19 14.56 1844 510 3.06 / 305.54 2 2
6 13 487.04 19 14.81 1078 303 3.36 / 305.84 2 3
7 8 -0.08 175 15.00 340 892 4.25 / 306.73 2 4
Average= 4.20
(KJ/cycle)

Cycle 71 GMT 2/ 7/2019 7:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 28 15.08 0 0 0.00 / 298.17 2 2
2 7 2002.56 42 14.30 3035 1823 1.82 / 299.99 2 2
3 13 1589.52 19 14.39 2536 693 2.52 / 300.68 2 3
4 13 1028.08 19 14.57 1815 502 3.02 / 301.19 2 2
5 13 464.00 19 14.82 1039 293 3.31 / 301.48 2 3
6 13 33.56 19 15.05 387 111 3.42 / 301.59 2 2
7 8 0.32 175 14.99 340 892 4.31 / 302.48 2 6
Average= 4.20
(KJ/cycle)

Cycle 70 GMT 22/ 6/2019 7:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 28 15.11 0 0 0.00 / 293.43 2 2
2 7 2004.12 42 14.30 3035 1823 1.82 / 295.25 2 2
3 13 1603.36 19 14.39 2548 697 2.52 / 295.95 2 2
4 13 1180.52 19 14.50 2005 552 3.07 / 296.50 2 6
5 13 585.32 19 14.76 1203 337 3.41 / 296.84 2 4
6 13 25.60 19 15.05 379 108 3.52 / 296.95 2 2
7 8 -0.04 175 14.99 340 892 4.41 / 297.84 2 4
8 14 -0.04 65 14.94 339 329 4.74 / 298.17 2 8
Average= 4.20
(KJ/cycle)

Cycle 69 GMT 12/ 6/2019 7:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 27 15.10 0 0 0.00 / 289.28 2 2
2 3 1033.16 1 15.49 0 0 0.00 / 289.28 2 2
3 7 2005.28 42 14.30 3031 1820 1.82 / 291.10 2 2
4 13 1605.84 19 14.39 2566 702 2.52 / 291.80 2 2
5 13 1048.60 19 14.57 1820 504 3.03 / 292.30 2 3
6 13 352.92 19 14.89 880 249 3.27 / 292.55 2 2
7 8 0.00 175 15.02 333 875 4.15 / 293.43 2 3
Average= 4.19
(KJ/cycle)

Cycle 68 GMT 2/ 6/2019 8: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 28 15.09 0 0 0.00 / 285.04 2 2
2 3 973.44 -1 15.52 0 0 0.00 / 285.04 2 2
3 7 2006.56 42 14.29 3072 1844 1.84 / 286.89 2 2
4 13 1598.96 19 14.38 2553 698 2.54 / 287.59 2 2
5 13 1051.00 19 14.57 1833 507 3.05 / 288.09 2 3
6 13 475.76 19 14.82 1066 300 3.35 / 288.39 2 3
7 8 0.20 175 15.00 337 885 4.23 / 289.28 2 4
Average= 4.19
(KJ/cycle)

Cycle 67 GMT 23/ 5/2019 8:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 28 15.11 0 0 0.00 / 280.68 2 2
2 7 2003.84 42 14.30 3050 1832 1.83 / 282.51 2 2
3 13 1597.32 19 14.39 2559 700 2.53 / 283.21 2 2
4 13 1167.80 19 14.52 1981 547 3.08 / 283.76 2 3
5 13 449.72 19 14.84 1015 286 3.36 / 284.04 2 2
6 13 37.64 19 15.05 394 113 3.48 / 284.16 2 2
7 8 0.04 175 15.00 338 887 4.36 / 285.04 2 3
Average= 4.19
(KJ/cycle)

Cycle 66 GMT 13/ 5/2019 8:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 28 15.10 0 0 0.00 / 276.41 2 2
2 7 2003.92 42 14.31 3043 1829 1.83 / 278.24 2 2
3 13 1594.68 19 14.39 2542 695 2.52 / 278.93 2 3
4 13 1162.96 19 14.52 1964 542 3.07 / 279.47 2 4
5 13 563.12 19 14.78 1177 331 3.40 / 279.80 2 5
6 8 0.04 175 15.01 334 877 4.27 / 280.68 2 3
Average= 4.19
(KJ/cycle)

Cycle 65 GMT 3/ 5/2019 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 28 15.10 0 0 0.00 / 271.96 2 2
2 7 2009.20 42 14.30 3040 1826 1.83 / 273.79 2 2
3 13 1736.88 19 14.34 2743 747 2.57 / 274.53 2 2
4 13 1147.80 19 14.53 1945 537 3.11 / 275.07 2 3
5 13 547.20 19 14.78 1156 325 3.43 / 275.40 2 4
6 13 46.64 19 15.04 416 119 3.55 / 275.52 2 2
7 8 0.08 175 14.99 340 892 4.45 / 276.41 2 5
Average= 4.19
(KJ/cycle)

Cycle 64 GMT 23/ 4/2019 9:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 28 15.11 0 0 0.00 / 267.68 2 2
2 7 2007.40 42 14.30 3056 1835 1.84 / 269.51 2 2
3 13 1471.64 19 14.45 2378 653 2.49 / 270.17 2 2
4 13 1030.76 19 14.57 1802 499 2.99 / 270.67 2 3
5 13 454.84 19 14.84 1035 292 3.28 / 270.96 2 2
6 13 28.44 19 15.05 389 111 3.39 / 271.07 2 2
7 8 0.00 175 14.99 340 892 4.28 / 271.96 2 4
Average= 4.18
(KJ/cycle)

Cycle 63 GMT 13/ 4/2019 9:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 28 15.11 0 0 0.00 / 263.30 2 2
2 7 2003.44 42 14.32 3024 1819 1.82 / 265.12 2 2
3 13 1729.48 19 14.36 2714 740 2.56 / 265.86 2 2
4 13 1152.32 19 14.53 1953 539 3.10 / 266.40 2 2
5 13 443.60 19 14.85 1015 286 3.38 / 266.68 2 2
6 13 30.24 19 15.06 387 111 3.50 / 266.79 2 2
7 8 0.04 175 15.00 337 885 4.38 / 267.68 2 3
Average= 4.18
(KJ/cycle)

Cycle 62 GMT 3/ 4/2019 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 28 15.12 0 0 0.00 / 258.92 2 2
2 7 2005.80 43 14.31 3034 1867 1.87 / 260.79 2 2
3 13 1606.44 19 14.40 2568 703 2.57 / 261.49 2 4
4 13 1035.20 19 14.59 1800 499 3.07 / 261.99 2 3
5 13 473.40 19 14.83 1056 298 3.37 / 262.29 2 4
6 13 33.88 19 15.05 401 115 3.48 / 262.40 2 2
7 8 0.16 175 15.00 341 895 4.38 / 263.30 2 3
Average= 4.18
(KJ/cycle)

Cycle 61 GMT 24/ 3/2019 10:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 28 15.12 0 0 0.00 / 254.57 2 2
2 7 2006.80 42 14.32 3033 1824 1.82 / 256.40 2 2
3 13 1742.16 19 14.36 2736 746 2.57 / 257.14 2 2
4 13 1144.72 19 14.55 1934 535 3.11 / 257.68 2 4
5 13 417.68 19 14.87 974 275 3.38 / 257.95 2 3
6 13 26.24 19 15.06 377 108 3.49 / 258.06 2 2
7 8 0.00 175 15.01 328 862 4.35 / 258.92 2 5
Average= 4.18
(KJ/cycle)

Cycle 60 GMT 14/ 3/2019 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 28 15.12 0 0 0.00 / 250.30 2 2
2 7 2007.36 42 14.32 3036 1826 1.83 / 252.13 2 2
3 13 1606.60 19 14.41 2563 702 2.53 / 252.83 2 2
4 13 1042.40 19 14.59 1815 503 3.03 / 253.33 2 2
5 13 339.72 19 14.91 867 246 3.28 / 253.58 2 2
6 13 40.44 19 15.06 402 115 3.39 / 253.69 2 2
7 8 0.24 175 15.02 335 881 4.27 / 254.57 2 5
Average= 4.17
(KJ/cycle)

Cycle 59 GMT 4/ 3/2019 10:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 28 15.13 0 0 0.00 / 245.87 2 2
2 7 2005.28 42 14.33 3025 1821 1.82 / 247.69 2 2
3 13 1731.92 19 14.37 2727 745 2.57 / 248.43 2 3
4 13 1149.96 19 14.55 1942 537 3.10 / 248.97 2 4
5 13 554.96 19 14.81 1159 326 3.43 / 249.30 2 3
6 13 24.04 19 15.07 384 110 3.54 / 249.40 2 2
7 8 0.12 175 15.02 341 896 4.43 / 250.30 2 2
Average= 4.17
(KJ/cycle)

Cycle 58 GMT 22/ 2/2019 11:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 28 15.13 0 0 0.00 / 241.72 2 2
2 7 2005.44 42 14.32 3049 1834 1.83 / 243.56 2 2
3 13 1581.20 19 14.44 2507 688 2.52 / 244.25 2 2
4 13 1025.48 19 14.61 1804 501 3.02 / 244.75 2 5
5 13 306.48 19 14.93 826 234 3.26 / 244.98 2 2
6 8 0.08 175 15.03 337 886 4.14 / 245.87 2 4
Average= 4.17
(KJ/cycle)

Cycle 57 GMT 12/ 2/2019 11:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 28 15.13 0 0 0.00 / 237.42 2 2
2 7 2002.00 43 14.33 3028 1866 1.87 / 239.28 2 2
3 13 1726.32 19 14.39 2670 730 2.60 / 240.01 2 2
4 13 1002.00 19 14.62 1768 491 3.09 / 240.50 2 3
5 13 292.08 19 14.95 795 226 3.31 / 240.73 2 2
6 13 29.16 19 15.07 384 110 3.42 / 240.84 2 2
7 8 0.12 175 15.02 337 886 4.31 / 241.72 2 5
Average= 4.17
(KJ/cycle)

Cycle 56 GMT 2/ 2/2019 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 28 15.14 0 0 0.00 / 233.12 2 2
2 7 2007.12 42 14.33 3063 1843 1.84 / 234.97 2 2
3 13 1610.24 19 14.44 2521 692 2.54 / 235.66 2 2
4 13 1051.84 19 14.61 1832 509 3.04 / 236.17 2 5
5 13 361.84 19 14.92 881 250 3.29 / 236.42 2 2
6 13 23.88 19 15.08 379 109 3.40 / 236.53 2 2
7 8 -0.04 175 15.03 338 889 4.29 / 237.42 2 3
Average= 4.17
(KJ/cycle)

Cycle 55 GMT 23/ 1/2019 12:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 28 15.15 0 0 0.00 / 228.94 2 2
2 7 2004.92 42 14.33 3063 1843 1.84 / 230.78 2 2
3 13 1592.96 19 14.44 2533 695 2.54 / 231.48 2 3
4 13 1032.72 19 14.62 1808 502 3.04 / 231.98 2 7
5 13 326.64 19 14.93 850 241 3.28 / 232.22 2 2
6 8 0.20 175 15.04 343 903 4.18 / 233.12 2 4
Average= 4.16
(KJ/cycle)

Cycle 54 GMT 13/ 1/2019 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 28 15.14 0 0 0.00 / 224.72 2 2
2 7 2005.80 42 14.35 3017 1818 1.82 / 226.54 2 2
3 13 1608.24 19 14.44 2559 702 2.52 / 227.24 2 2
4 13 1175.28 19 14.56 1986 549 3.07 / 227.79 2 4
5 13 320.28 19 14.94 845 240 3.31 / 228.03 2 2
6 8 0.04 175 15.04 344 905 4.22 / 228.94 2 5
Average= 4.16
(KJ/cycle)

Cycle 53 GMT 3/ 1/2019 12:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 28 15.15 0 0 0.00 / 220.48 2 2
2 7 2007.40 42 14.35 3048 1837 1.84 / 222.32 2 2
3 13 1597.40 19 14.44 2540 697 2.53 / 223.02 2 2
4 13 1026.64 19 14.64 1790 498 3.03 / 223.51 2 2
5 13 455.24 19 14.88 1023 289 3.32 / 223.80 2 3
6 8 0.12 175 15.04 350 921 4.24 / 224.72 2 6
Average= 4.16
(KJ/cycle)

Cycle 52 GMT 24/12/2018 12:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 27 15.16 0 0 0.00 / 216.39 2 2
2 3 1034.68 1 15.51 0 0 0.00 / 216.39 2 2
3 7 2003.40 42 14.35 3038 1831 1.83 / 218.22 2 2
4 13 1469.92 19 14.50 2379 655 2.49 / 218.88 2 2
5 13 1056.20 19 14.63 1829 508 2.99 / 219.39 2 4
6 13 216.76 19 15.01 676 193 3.19 / 219.58 2 2
7 8 0.04 175 15.06 342 901 4.09 / 220.48 2 4
Average= 4.16
(KJ/cycle)

Cycle 51 GMT 14/12/2018 13: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 27 15.16 0 0 0.00 / 212.19 2 2
2 7 2003.24 42 14.34 3059 1842 1.84 / 214.03 2 2
3 13 1591.72 19 14.46 2539 698 2.54 / 214.73 2 2
4 13 1057.00 19 14.63 1836 510 3.05 / 215.24 2 2
5 13 352.08 19 14.94 885 251 3.30 / 215.49 2 3
6 8 0.08 175 15.06 342 901 4.20 / 216.39 2 5
Average= 4.16
(KJ/cycle)

Cycle 50 GMT 4/12/2018 13:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 27 15.16 0 0 0.00 / 208.03 2 2
2 7 2006.28 42 14.36 3017 1820 1.82 / 209.85 2 2
3 13 1601.00 19 14.46 2550 701 2.52 / 210.55 2 2
4 13 1035.48 19 14.64 1812 504 3.02 / 211.05 2 3
5 13 304.56 19 14.96 824 234 3.26 / 211.28 2 2
6 8 0.32 175 15.06 344 907 4.17 / 212.19 2 4
Average= 4.16
(KJ/cycle)

Cycle 49 GMT 24/11/2018 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 27 15.16 0 0 0.00 / 203.83 2 2
2 7 2003.96 42 14.36 3028 1826 1.83 / 205.66 2 2
3 13 1613.84 19 14.47 2528 695 2.52 / 206.36 2 2
4 13 1059.20 19 14.64 1834 510 3.03 / 206.87 2 3
5 13 341.44 19 14.96 870 247 3.28 / 207.11 2 2
6 8 0.12 175 15.06 346 912 4.19 / 208.03 2 4
Average= 4.16
(KJ/cycle)

Cycle 48 GMT 14/11/2018 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 27 15.17 0 0 0.00 / 199.65 2 2
2 7 2004.96 42 14.36 3048 1838 1.84 / 201.49 2 2
3 13 1593.88 19 14.48 2514 692 2.53 / 202.18 2 2
4 13 913.16 19 14.72 1638 458 2.99 / 202.64 2 4
5 13 483.56 19 14.89 1061 300 3.29 / 202.94 2 2
6 8 0.00 175 15.06 341 899 4.19 / 203.83 2 5
Average= 4.16
(KJ/cycle)

Cycle 47 GMT 4/11/2018 14:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 27 15.17 0 0 0.00 / 195.37 2 2
2 7 2008.08 42 14.35 3061 1845 1.84 / 197.21 2 2
3 13 1734.84 19 14.42 2728 747 2.59 / 197.96 2 2
4 13 1160.48 19 14.61 1975 548 3.14 / 198.51 2 2
5 13 298.48 19 14.99 814 232 3.37 / 198.74 2 2
6 8 0.08 175 15.07 345 910 4.28 / 199.65 2 3
Average= 4.16
(KJ/cycle)

Cycle 46 GMT 25/10/2018 14:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 27 15.17 0 0 0.00 / 191.09 2 2
2 7 2002.72 42 14.37 3034 1831 1.83 / 192.92 2 2
3 13 1728.88 19 14.43 2712 744 2.57 / 193.66 2 2
4 13 1009.80 19 14.67 1778 496 3.07 / 194.16 2 4
5 13 436.44 19 14.92 1009 286 3.36 / 194.45 2 3
6 8 0.28 175 15.07 349 920 4.28 / 195.37 2 4
Average= 4.16
(KJ/cycle)

Cycle 45 GMT 15/10/2018 14:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 27 15.17 0 0 0.00 / 186.88 2 2
2 7 2005.28 43 14.36 3023 1867 1.87 / 188.75 2 2
3 13 1593.96 19 14.49 2524 695 2.56 / 189.44 2 2
4 13 1019.68 19 14.67 1788 498 3.06 / 189.94 2 2
5 13 317.04 19 14.98 835 238 3.30 / 190.18 2 2
6 8 0.00 175 15.07 346 912 4.21 / 191.09 2 3
Average= 4.15
(KJ/cycle)

Cycle 44 GMT 5/10/2018 15:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 27 15.18 0 0 0.00 / 182.69 2 2
2 7 2007.44 42 14.38 3018 1823 1.82 / 184.51 2 2
3 13 1588.40 19 14.49 2537 698 2.52 / 185.21 2 4
4 13 1025.64 19 14.67 1804 503 3.02 / 185.72 2 4
5 13 321.72 19 14.98 843 240 3.26 / 185.96 2 2
6 8 0.04 175 15.08 350 924 4.19 / 186.88 2 5
Average= 4.15
(KJ/cycle)

Cycle 43 GMT 25/ 9/2018 15:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 27 15.19 0 0 0.00 / 178.50 2 2
2 7 2002.80 42 14.38 3025 1827 1.83 / 180.33 2 2
3 13 1604.44 19 14.49 2553 703 2.53 / 181.03 2 2
4 13 1028.28 19 14.68 1789 499 3.03 / 181.53 2 3
5 13 324.04 19 14.99 841 240 3.27 / 181.77 2 2
6 8 0.24 175 15.08 349 921 4.19 / 182.69 2 4
Average= 4.15
(KJ/cycle)

Cycle 42 GMT 15/ 9/2018 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 27 15.19 0 0 0.00 / 174.22 2 2
2 7 2004.20 43 14.38 3021 1868 1.87 / 176.09 2 2
3 13 1735.64 19 14.44 2731 749 2.62 / 176.84 2 2
4 13 1021.60 19 14.69 1792 500 3.12 / 177.34 2 3
5 13 314.92 19 15.00 832 237 3.35 / 177.58 2 2
6 8 0.04 175 15.08 350 924 4.28 / 178.50 2 3
Average= 4.15
(KJ/cycle)

Cycle 41 GMT 5/ 9/2018 16: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 27 15.18 0 0 0.00 / 169.91 2 2
2 7 2003.04 43 14.37 3035 1875 1.88 / 171.78 2 2
3 13 1619.52 19 14.49 2563 706 2.58 / 172.49 2 2
4 13 1166.36 19 14.62 1971 548 3.13 / 173.04 2 2
5 13 397.56 19 14.95 949 270 3.40 / 173.30 2 2
6 8 0.32 175 15.09 348 919 4.32 / 174.22 2 4
Average= 4.15
(KJ/cycle)

Cycle 40 GMT 26/ 8/2018 16:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 27 15.19 0 0 0.00 / 165.45 2 2
2 7 2007.40 43 14.37 3035 1875 1.88 / 167.33 2 2
3 13 1880.04 19 14.39 2932 802 2.68 / 168.13 2 2
4 13 1111.60 19 14.65 1910 532 3.21 / 168.66 2 3
5 13 523.36 19 14.90 1123 318 3.53 / 168.98 2 2
6 8 -0.12 175 15.08 352 929 4.46 / 169.91 2 3
Average= 4.14
(KJ/cycle)

Cycle 39 GMT 16/ 8/2018 16:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 26 15.20 0 0 0.00 / 161.11 2 2
2 3 1060.24 2 15.53 0 0 0.00 / 161.11 2 2
3 7 2006.52 42 14.38 3022 1825 1.83 / 162.94 2 2
4 13 1599.60 19 14.51 2533 698 2.52 / 163.64 2 2
5 13 1175.88 19 14.62 1993 554 3.08 / 164.19 2 3
6 13 591.76 19 14.87 1213 343 3.42 / 164.53 2 3
7 8 -0.12 175 15.09 348 919 4.34 / 165.45 2 5
Average= 4.14
(KJ/cycle)

Cycle 38 GMT 6/ 8/2018 17:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 28 15.19 0 0 0.00 / 156.85 2 2
2 3 944.32 -1 15.53 0 0 0.00 / 156.85 2 2
3 7 2007.84 42 14.39 3028 1830 1.83 / 158.68 2 2
4 13 1607.72 19 14.51 2549 703 2.53 / 159.39 2 2
5 13 1048.76 19 14.68 1819 507 3.04 / 159.89 2 5
6 13 472.16 19 14.93 1046 297 3.34 / 160.19 2 4
7 8 0.20 175 15.09 349 922 4.26 / 161.11 2 10
Average= 4.13
(KJ/cycle)

Cycle 37 GMT 27/ 7/2018 17:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 28 15.21 0 0 0.00 / 152.52 2 2
2 7 2003.24 42 14.39 3026 1829 1.83 / 154.35 2 2
3 13 1605.12 19 14.51 2562 706 2.54 / 155.06 2 2
4 13 1164.40 19 14.64 1971 548 3.08 / 155.61 2 6
5 13 303.72 19 15.02 813 232 3.32 / 155.84 2 2
6 13 14.72 19 15.15 366 105 3.42 / 155.94 2 2
7 8 0.00 175 15.09 345 911 4.33 / 156.85 2 7
Average= 4.13
(KJ/cycle)

Cycle 36 GMT 17/ 7/2018 17:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 28 15.21 0 0 0.00 / 148.35 2 2
2 7 2007.52 42 14.40 3015 1823 1.82 / 150.17 2 2
3 13 1595.72 19 14.51 2546 702 2.53 / 150.88 2 2
4 13 1035.44 19 14.69 1810 505 3.03 / 151.38 2 5
5 13 319.00 19 15.01 839 239 3.27 / 151.62 2 2
6 8 0.24 175 15.11 341 902 4.17 / 152.52 2 4
Average= 4.12
(KJ/cycle)

Cycle 35 GMT 7/ 7/2018 17:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 28 15.21 0 0 0.00 / 144.23 2 2
2 7 2003.96 42 14.39 3037 1836 1.84 / 146.06 2 2
3 13 1461.28 19 14.57 2350 651 2.49 / 146.71 2 2
4 13 1045.00 19 14.69 1828 510 3.00 / 147.22 2 4
5 13 320.48 19 15.01 834 238 3.23 / 147.46 2 2
6 8 0.00 175 15.11 336 888 4.12 / 148.35 2 6
Average= 4.12
(KJ/cycle)

Cycle 34 GMT 27/ 6/2018 18: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 28 15.22 0 0 0.00 / 140.05 2 2
2 7 2003.72 42 14.41 3015 1825 1.82 / 141.88 2 2
3 13 1468.68 19 14.56 2368 655 2.48 / 142.53 2 3
4 13 1052.72 19 14.69 1821 508 2.99 / 143.04 2 6
5 13 469.08 19 14.94 1043 296 3.28 / 143.34 2 4
6 8 -0.04 175 15.12 336 889 4.17 / 144.23 2 5
Average= 4.12
(KJ/cycle)

Cycle 33 GMT 17/ 6/2018 18:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 28 15.22 0 0 0.00 / 135.88 2 2
2 7 2004.24 42 14.40 3038 1837 1.84 / 137.71 2 2
3 13 1485.04 19 14.56 2392 662 2.50 / 138.37 2 2
4 13 1198.32 19 14.63 2004 557 3.06 / 138.93 2 6
5 13 330.92 19 15.02 848 242 3.30 / 139.17 2 2
6 8 0.04 175 15.12 333 881 4.18 / 140.05 2 4
Average= 4.12
(KJ/cycle)

Cycle 32 GMT 7/ 6/2018 18:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 28 15.22 0 0 0.00 / 131.69 2 2
2 7 2002.76 42 14.40 3047 1843 1.84 / 133.53 2 2
3 13 1594.88 19 14.53 2523 697 2.54 / 134.23 2 2
4 13 1031.96 19 14.71 1808 505 3.04 / 134.73 2 5
5 13 322.96 19 15.03 832 238 3.28 / 134.97 2 3
6 8 0.20 175 15.12 342 905 4.19 / 135.88 2 6
Average= 4.12
(KJ/cycle)

Cycle 31 GMT 28/ 5/2018 18:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 28 15.22 0 0 0.00 / 127.29 2 2
2 7 2007.80 42 14.40 3066 1854 1.85 / 129.14 2 2
3 13 1604.48 19 14.52 2564 707 2.56 / 129.85 2 2
4 13 1160.24 19 14.66 1967 548 3.11 / 130.40 2 4
5 13 425.40 19 14.98 988 281 3.39 / 130.68 2 3
6 13 53.64 19 15.15 424 122 3.51 / 130.80 2 2
7 8 -0.08 175 15.12 335 886 4.40 / 131.69 2 3
Average= 4.12
(KJ/cycle)

Cycle 30 GMT 18/ 5/2018 18:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 28 15.22 0 0 0.00 / 122.92 2 2
2 7 2004.48 42 14.41 3020 1828 1.83 / 124.75 2 2
3 13 1731.56 19 14.48 2732 752 2.58 / 125.50 2 2
4 13 1011.12 19 14.73 1781 498 3.08 / 126.00 2 2
5 13 459.12 19 14.96 1034 294 3.37 / 126.29 2 4
6 13 34.48 19 15.17 387 112 3.48 / 126.40 2 2
7 8 0.12 175 15.12 335 886 4.37 / 127.29 2 3
Average= 4.11
(KJ/cycle)

Cycle 29 GMT 8/ 5/2018 19: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 27 15.23 0 0 0.00 / 118.63 2 2
2 7 2005.08 42 14.41 3038 1839 1.84 / 120.47 2 2
3 13 1594.28 19 14.53 2541 701 2.54 / 121.17 2 3
4 13 1035.36 19 14.72 1807 505 3.05 / 121.67 2 4
5 13 322.96 19 15.03 844 241 3.29 / 121.91 2 2
6 13 36.24 19 15.17 394 114 3.40 / 122.03 2 2
7 8 0.28 175 15.12 337 892 4.29 / 122.92 2 6
Average= 4.10
(KJ/cycle)

Cycle 28 GMT 28/ 4/2018 19: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 27 15.23 0 0 0.00 / 114.41 2 2
2 7 2003.04 42 14.41 3035 1837 1.84 / 116.24 2 2
3 13 1468.64 19 14.58 2365 655 2.49 / 116.90 2 2
4 13 1048.56 19 14.71 1822 509 3.00 / 117.41 2 3
5 13 326.40 19 15.03 846 242 3.24 / 117.65 2 2
6 13 33.44 19 15.17 385 111 3.35 / 117.76 2 2
7 8 0.12 175 15.13 328 868 4.22 / 118.63 2 3
Average= 4.09
(KJ/cycle)

Cycle 27 GMT 18/ 4/2018 19: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 27 15.23 0 0 0.00 / 110.14 2 2
2 7 2003.24 42 14.42 3055 1850 1.85 / 111.99 2 2
3 13 1575.20 19 14.56 2486 688 2.54 / 112.68 2 3
4 13 1012.88 19 14.73 1781 498 3.04 / 113.18 2 4
5 13 304.28 19 15.05 810 232 3.27 / 113.41 2 2
6 13 29.08 19 15.18 380 110 3.38 / 113.52 2 2
7 8 0.04 175 15.13 334 884 4.26 / 114.41 2 4
Average= 4.09
(KJ/cycle)

Cycle 26 GMT 8/ 4/2018 19:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 27 15.23 0 0 0.00 / 105.80 2 2
2 7 2006.08 42 14.42 3030 1835 1.84 / 107.64 2 2
3 13 1608.92 19 14.55 2531 700 2.53 / 108.33 2 2
4 13 1048.04 19 14.72 1830 512 3.05 / 108.85 2 3
5 13 474.24 19 14.96 1049 298 3.34 / 109.14 2 3
6 13 34.32 19 15.18 396 114 3.46 / 109.26 2 2
7 8 -0.04 175 15.13 334 884 4.34 / 110.14 2 4
Average= 4.08
(KJ/cycle)

Cycle 25 GMT 29/ 3/2018 19:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 28 15.23 0 0 0.00 / 101.44 2 2
2 7 2005.48 42 14.42 3047 1845 1.85 / 103.29 2 2
3 13 1596.08 19 14.55 2536 701 2.55 / 103.99 2 2
4 13 1040.64 19 14.72 1824 510 3.06 / 104.50 2 3
5 13 460.64 19 14.97 1033 294 3.35 / 104.79 2 3
6 13 34.76 19 15.18 388 112 3.46 / 104.91 2 2
7 8 0.04 175 15.13 338 895 4.36 / 105.80 2 3
Average= 4.07
(KJ/cycle)

Cycle 24 GMT 19/ 3/2018 19:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 27 15.24 0 0 0.00 / 97.14 2 2
2 7 2003.96 42 14.42 3053 1849 1.85 / 98.99 2 2
3 13 1593.16 19 14.55 2530 699 2.55 / 99.69 2 2
4 13 1024.60 19 14.74 1785 500 3.05 / 100.19 2 4
5 13 315.00 19 15.04 833 238 3.29 / 100.43 2 2
6 13 35.56 19 15.18 402 116 3.40 / 100.54 2 2
7 8 0.00 175 15.13 340 900 4.30 / 101.44 2 3
Average= 4.06
(KJ/cycle)

Cycle 23 GMT 9/ 3/2018 19:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 27 15.24 0 0 0.00 / 92.91 2 2
2 7 2006.80 42 14.43 3054 1851 1.85 / 94.76 2 2
3 13 1601.12 19 14.55 2553 706 2.56 / 95.47 2 2
4 13 1029.72 19 14.74 1805 506 3.06 / 95.97 2 6
5 13 202.52 19 15.12 653 188 3.25 / 96.16 2 2
6 13 22.84 19 15.19 369 106 3.36 / 96.27 2 2
7 8 0.04 175 15.14 330 874 4.23 / 97.14 2 3
Average= 4.05
(KJ/cycle)

Cycle 22 GMT 27/ 2/2018 19:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 27 15.24 0 0 0.00 / 88.59 2 2
2 7 2004.08 42 14.44 3014 1828 1.83 / 90.41 2 2
3 13 1607.88 19 14.56 2554 707 2.53 / 91.12 2 2
4 13 1042.04 19 14.74 1811 507 3.04 / 91.63 2 3
5 13 465.76 19 14.98 1043 297 3.34 / 91.92 2 2
6 13 29.72 19 15.19 385 111 3.45 / 92.04 2 2
7 8 0.16 175 15.14 330 874 4.32 / 92.91 2 5
Average= 4.04
(KJ/cycle)

Cycle 21 GMT 17/ 2/2018 19:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 27 15.24 0 0 0.00 / 84.33 2 2
2 7 2004.04 42 14.45 3019 1832 1.83 / 86.16 2 2
3 13 1458.60 19 14.61 2362 656 2.49 / 86.82 2 2
4 13 1051.52 19 14.73 1821 510 3.00 / 87.33 2 4
5 13 326.08 19 15.05 854 244 3.24 / 87.57 2 2
6 13 34.44 19 15.19 392 113 3.35 / 87.68 2 2
7 8 0.12 175 15.14 340 901 4.26 / 88.59 2 4
Average= 4.03
(KJ/cycle)

Cycle 20 GMT 7/ 2/2018 20:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 27 15.25 0 0 0.00 / 80.06 2 2
2 7 2002.96 43 14.45 3002 1865 1.87 / 81.92 2 2
3 13 1455.08 19 14.62 2335 649 2.51 / 82.57 2 2
4 13 1027.52 19 14.74 1802 505 3.02 / 83.08 2 4
5 13 305.28 19 15.07 815 233 3.25 / 83.31 2 2
6 13 29.52 19 15.19 385 111 3.36 / 83.42 2 2
7 8 -0.04 175 15.14 343 909 4.27 / 84.33 2 5
Average= 4.02
(KJ/cycle)

Cycle 19 GMT 28/ 1/2018 20:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 27 15.25 0 0 0.00 / 75.85 2 2
2 7 2007.84 42 14.46 3018 1833 1.83 / 77.68 2 2
3 13 1600.36 19 14.59 2520 699 2.53 / 78.38 2 3
4 13 1034.92 19 14.76 1784 500 3.03 / 78.88 2 3
5 13 446.32 19 15.00 1010 288 3.32 / 79.17 2 4
6 8 -0.08 175 15.16 336 891 4.21 / 80.06 2 5
Average= 4.00
(KJ/cycle)

Cycle 18 GMT 18/ 1/2018 20:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 27 15.26 0 0 0.00 / 71.53 2 2
2 7 2003.04 42 14.46 3020 1834 1.83 / 73.36 2 2
3 13 1603.40 19 14.58 2532 701 2.54 / 74.07 2 2
4 13 1040.44 19 14.75 1832 513 3.05 / 74.58 2 5
5 13 336.12 19 15.06 867 248 3.30 / 74.83 2 2
6 13 17.44 19 15.21 366 106 3.40 / 74.93 2 2
7 8 0.08 175 15.15 345 915 4.32 / 75.85 2 5
Average= 3.99
(KJ/cycle)

Cycle 17 GMT 8/ 1/2018 20:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 27 15.27 0 0 0.00 / 67.36 2 2
2 7 2004.16 42 14.46 3042 1847 1.85 / 69.20 2 2
3 13 1584.08 19 14.60 2500 693 2.54 / 69.90 2 2
4 13 1015.76 19 14.76 1784 500 3.04 / 70.40 2 2
5 13 293.28 19 15.08 790 226 3.27 / 70.62 2 2
6 8 0.16 175 15.16 341 905 4.17 / 71.53 2 4
Average= 3.97
(KJ/cycle)

Cycle 16 GMT 29/12/2017 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 27 15.27 0 0 0.00 / 63.17 2 2
2 7 2002.88 42 14.46 3060 1858 1.86 / 65.03 2 2
3 13 1583.32 19 14.59 2511 696 2.55 / 65.72 2 2
4 13 1027.96 19 14.76 1803 506 3.06 / 66.23 2 5
5 13 321.72 19 15.07 835 239 3.30 / 66.47 2 2
6 8 -0.08 175 15.17 335 889 4.19 / 67.36 2 3
Average= 3.96
(KJ/cycle)

Cycle 15 GMT 19/12/2017 21:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 27 15.26 0 0 0.00 / 59.02 2 2
2 7 2004.60 42 14.49 2994 1822 1.82 / 60.84 2 2
3 13 1583.00 19 14.60 2480 688 2.51 / 61.53 2 2
4 13 1145.08 19 14.72 1922 538 3.05 / 62.07 2 3
5 13 285.32 19 15.09 774 222 3.27 / 62.29 2 2
6 8 0.04 175 15.17 332 881 4.15 / 63.17 2 4
Average= 3.95
(KJ/cycle)

Cycle 14 GMT 9/12/2017 21:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 27 15.27 0 0 0.00 / 54.96 2 2
2 7 2009.52 42 14.47 3029 1841 1.84 / 56.80 2 2
3 13 1462.96 19 14.64 2337 650 2.49 / 57.45 2 2
4 13 903.80 19 14.82 1626 458 2.95 / 57.91 2 5
5 13 215.08 19 15.13 675 194 3.14 / 58.10 2 2
6 8 0.12 175 15.17 346 919 4.06 / 59.02 2 5
Average= 3.93
(KJ/cycle)

Cycle 13 GMT 29/11/2017 21:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 27 15.27 0 0 0.00 / 50.77 2 2
2 7 2002.76 42 14.49 3017 1836 1.84 / 52.61 2 2
3 13 1589.68 19 14.60 2524 700 2.54 / 53.31 2 2
4 13 1019.72 19 14.78 1772 498 3.03 / 53.80 2 6
5 13 319.48 19 15.08 827 237 3.27 / 54.04 2 2
6 8 0.08 175 15.17 345 916 4.19 / 54.96 2 4
Average= 3.93
(KJ/cycle)

Cycle 12 GMT 19/11/2017 21:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 27 15.28 0 0 0.00 / 46.35 2 2
2 7 2002.64 44 14.48 3008 1916 1.92 / 48.27 2 2
3 13 1589.32 25 14.57 2511 915 2.83 / 49.18 2 2
4 13 843.32 25 14.83 1516 562 3.39 / 49.75 2 4
5 13 43.92 25 15.21 411 156 3.55 / 49.90 2 2
6 8 0.20 165 15.16 347 868 4.42 / 50.77 2 5
Average= 3.91
(KJ/cycle)

Cycle 11 GMT 9/11/2017 21:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 27 15.27 0 0 0.00 / 42.02 2 2
2 7 2004.36 44 14.49 3000 1913 1.91 / 43.93 2 2
3 13 1453.88 25 14.63 2288 837 2.75 / 44.77 2 2
4 13 867.28 25 14.82 1565 580 3.33 / 45.35 2 4
5 13 25.16 25 15.22 382 145 3.47 / 45.50 2 2
6 8 -0.04 165 15.17 342 856 4.33 / 46.35 2 8
Average= 3.86
(KJ/cycle)

Cycle 10 GMT 30/10/2017 22: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 27 15.28 0 0 0.00 / 37.75 2 2
2 7 2001.56 44 14.50 2981 1902 1.90 / 39.65 2 2
3 13 1450.56 25 14.63 2316 847 2.75 / 40.50 2 2
4 13 742.96 25 14.88 1405 523 3.27 / 41.02 2 3
5 13 13.92 25 15.23 360 137 3.41 / 41.16 2 2
6 8 0.00 165 15.17 345 864 4.27 / 42.02 2 5
Average= 3.82
(KJ/cycle)

Cycle 9 GMT 20/10/2017 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 26 15.28 0 0 0.00 / 33.48 2 2
2 7 2003.68 48 14.49 3002 2088 2.09 / 35.57 2 2
3 13 1415.72 25 14.63 2269 830 2.92 / 36.40 2 4
4 13 666.56 25 14.92 1292 482 3.40 / 36.88 2 4
5 8 0.20 165 15.18 346 867 4.27 / 37.75 2 4
Average= 3.77
(KJ/cycle)

Cycle 8 GMT 10/10/2017 22:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 26 15.28 0 0 0.00 / 29.24 2 2
2 7 2013.52 48 14.47 3050 2118 2.12 / 31.36 2 2
3 13 1428.16 25 14.63 2288 837 2.96 / 32.20 2 2
4 13 534.52 25 14.98 1126 422 3.38 / 32.62 2 3
5 8 -0.12 165 15.18 344 862 4.24 / 33.48 2 7
Average= 3.72
(KJ/cycle)

Cycle 7 GMT 30/ 9/2017 22:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 26 15.28 0 0 0.00 / 24.96 2 2
2 3 1019.44 1 15.60 0 0 0.00 / 24.96 2 2
3 7 2002.76 48 14.50 3009 2094 2.09 / 27.06 2 2
4 13 1427.56 25 14.64 2288 837 2.93 / 27.90 2 2
5 13 678.44 25 14.92 1318 492 3.42 / 28.39 2 3
6 8 0.28 165 15.18 342 857 4.28 / 29.24 2 6
Average= 3.66
(KJ/cycle)

Cycle 6 GMT 20/ 9/2017 22:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 25 15.29 0 0 0.00 / 20.71 2 2
2 3 1037.16 1 15.60 0 0 0.00 / 20.71 2 2
3 7 2002.68 48 14.50 2992 2082 2.08 / 22.79 2 2
4 13 1429.28 25 14.64 2284 836 2.92 / 23.63 2 2
5 13 687.04 25 14.92 1322 493 3.41 / 24.12 2 5
6 8 0.08 165 15.19 336 842 4.25 / 24.96 2 4
Average= 3.57
(KJ/cycle)

Cycle 5 GMT 10/ 9/2017 22:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 24 15.26 0 0 0.00 / 16.43 2 2
2 3 1025.36 1 15.60 1 0 0.00 / 16.43 2 2
3 7 2001.64 37 14.56 3012 1623 1.62 / 18.05 2 2
4 13 1854.92 14 14.62 2876 589 2.21 / 18.64 2 3
5 13 1551.52 14 14.67 2472 508 2.72 / 19.15 2 3
6 13 1082.16 14 14.80 1843 382 3.10 / 19.53 2 5
7 13 619.28 14 14.98 1235 259 3.36 / 19.79 2 4
8 13 306.08 14 15.10 817 173 3.53 / 19.96 2 3
9 8 0.04 150 15.19 329 750 4.28 / 20.71 2 6
Average= 3.45
(KJ/cycle)

Cycle 4 GMT 31/ 8/2017 23:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 25 15.28 0 0 0.00 / 12.25 2 2
2 7 1513.20 74 14.68 2363 2567 2.57 / 14.82 2 3
3 13 273.80 25 15.13 747 283 2.85 / 15.10 2 3
4 13 17.88 25 15.24 356 136 2.99 / 15.24 2 2
5 8 0.04 240 15.17 327 1191 4.18 / 16.43 2 16
Average= 3.29
(KJ/cycle)

Cycle 3 GMT 31/ 8/2017 0:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 24 15.29 0 0 0.00 / 8.22 2 2
2 7 1513.64 74 14.67 2357 2559 2.56 / 10.78 2 3
3 13 408.84 25 15.08 912 344 2.90 / 11.12 2 4
4 8 0.20 240 15.18 311 1133 4.04 / 12.25 2 11
Average= 3.06
(KJ/cycle)

Cycle 2 GMT 30/ 8/2017 1:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 24 15.31 0 0 0.00 / 4.37 2 2
2 7 1516.88 74 14.70 2271 2470 2.47 / 6.84 2 2
3 13 322.96 25 15.12 783 296 2.77 / 7.14 2 3
4 8 0.08 240 15.20 296 1080 3.85 / 8.22 2 6
Average= 2.74
(KJ/cycle)

Cycle 1 GMT 29/ 8/2017 2: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 24 15.45 0 0 0.00 / 1.41 2 2
2 7 996.96 74 14.91 1678 1851 1.85 / 3.26 2 3
3 8 0.00 240 15.22 303 1107 2.96 / 4.37 2 10
Average= 2.19
(KJ/cycle)

Cycle 0 GMT 28/ 8/2017 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 24 15.67 0 0 0.00 / 0.00 2 2
2 7 115.72 74 15.52 420 482 0.48 / 0.48 2 2
3 8 0.20 240 15.45 251 931 1.41 / 1.41 2 3
Average= 1.41
(KJ/cycle)