SIO Argo Site:
Pump Diagnostics Page   



Serial= 8246 WMO= 5904530

Return

←PreviousNext→

Cycle 222 GMT 23/ 5/2019 5:11: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.24 42 10.60 446 199 0.20 / 1122.18 6 6
2 1136.36 110 6.71 1940 1432 1.63 / 1123.61 6 6
3 1138.88 31 6.84 1964 416 2.05 / 1124.03 6 6
4 1020.68 45 7.17 1784 576 2.62 / 1124.61 6 6
5 473.36 45 8.85 1041 415 3.04 / 1125.02 6 6
6 107.36 45 10.18 501 230 3.27 / 1125.25 6 6
7 0.04 170 10.67 321 582 3.85 / 1125.83 6 6
Average= 5.05 (KJ/cycle)

Cycle 221 GMT 13/ 5/2019 10:14: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.12 40 10.60 464 197 0.20 / 1118.20 6 6
2 1026.56 1 7.73 1732 13 0.21 / 1118.22 6 6
3 1019.80 1 7.60 1732 13 0.22 / 1118.23 6 6
4 1171.64 111 6.81 1988 1503 1.73 / 1119.73 6 6
5 1174.92 31 6.97 1995 431 2.16 / 1120.16 6 6
6 1058.76 44 7.21 1826 579 2.74 / 1120.74 6 6
7 512.28 45 8.81 1096 435 3.17 / 1121.18 6 6
8 110.16 45 10.23 498 229 3.40 / 1121.41 6 6
9 0.08 170 10.70 318 578 3.98 / 1121.98 6 6
Average= 5.05 (KJ/cycle)

Cycle 220 GMT 3/ 5/2019 15:13: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.44 41 10.60 446 194 0.19 / 1115.52 6 6
2 973.20 -1 10.60 446 0. 0.00 / 1115.52 6 6
3 1028.56 1 7.73 1821 14 0.21 / 1115.54 6 6
4 1028.88 31 7.30 1760 398 0.61 / 1115.94 6 6
5 950.32 45 7.52 1706 577 1.18 / 1116.51 6 6
6 600.76 45 8.60 1232 477 1.66 / 1116.99 6 6
7 113.20 45 10.23 508 234 1.89 / 1117.22 6 6
8 63.16 45 10.47 417 196 2.09 / 1117.42 6 6
9 0.16 170 10.72 321 585 2.68 / 1118.01 6 8
Average= 5.06 (KJ/cycle)

Cycle 219 GMT 23/ 4/2019 20:32: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.80 41 10.73 428 188 0.19 / 1108.41 6 6
2 972.48 -1 10.73 428 0. 0.00 / 1108.41 6 6
3 1032.44 1 8.18 1767 14 0.20 / 1108.42 6 6
4 1175.72 16 7.46 1986 237 0.44 / 1108.66 6 6
5 1804.72 111 5.31 3179 1874 2.31 / 1110.53 6 6
6 1799.96 31 5.13 3265 519 2.83 / 1111.05 6 6
7 1724.40 44 5.92 2796 728 3.56 / 1111.78 6 6
8 1645.20 45 6.16 2666 739 4.30 / 1112.52 6 6
9 1537.20 45 6.39 2452 705 5.01 / 1113.22 6 6
10 1030.92 45 7.54 1817 617 5.62 / 1113.84 6 6
11 619.92 45 8.70 1254 491 6.11 / 1114.33 6 6
12 103.36 45 10.38 484 226 6.34 / 1114.56 6 6
13 54.72 45 10.55 398 189 6.53 / 1114.74 6 6
14 -0.08 170 10.76 320 585 7.11 / 1115.33 6 7
Average= 5.07 (KJ/cycle)

Cycle 218 GMT 22/ 4/2019 16: 0: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.72 39 10.73 446 187 0.19 / 1104.50 6 6
2 1043.04 1 8.11 1767 14 0.20 / 1104.52 6 6
3 1029.00 1 8.18 1732 14 0.22 / 1104.53 6 6
4 1168.48 111 7.37 1976 1617 1.83 / 1106.15 6 6
5 1168.76 31 7.46 2016 466 2.30 / 1106.61 6 6
6 895.44 45 8.05 1644 596 2.89 / 1107.21 6 6
7 125.44 45 10.28 544 252 3.15 / 1107.46 6 6
8 68.76 45 10.50 437 206 3.35 / 1107.67 6 6
9 -0.04 170 10.81 300 551 3.90 / 1108.22 6 8
Average= 5.06 (KJ/cycle)

Cycle 217 GMT 12/ 4/2019 20:55: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.28 40 10.73 428 184 0.18 / 1100.59 6 6
2 948.00 -1 10.73 428 0. 0.00 / 1100.59 6 6
3 1170.04 111 7.54 1975 1653 1.84 / 1102.24 6 6
4 1171.40 31 7.59 1999 470 2.31 / 1102.71 6 6
5 777.28 45 8.51 1471 563 2.87 / 1103.28 6 6
6 120.76 45 10.36 525 245 3.12 / 1103.52 6 6
7 66.00 45 10.57 423 201 3.32 / 1103.72 6 6
8 0.08 170 10.79 322 591 3.91 / 1104.31 6 7
Average= 5.07 (KJ/cycle)

Cycle 216 GMT 3/ 4/2019 1:52: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.80 41 10.73 464 204 0.20 / 1098.08 6 6
2 1017.76 32 7.91 1736 439 0.64 / 1098.52 6 6
3 927.32 45 8.16 1647 605 1.25 / 1099.12 6 6
4 529.16 45 9.23 1114 463 1.71 / 1099.59 6 6
5 101.88 45 10.43 491 230 1.94 / 1099.82 6 6
6 -0.08 170 10.78 322 590 2.53 / 1100.41 6 6
Average= 5.07 (KJ/cycle)

Cycle 215 GMT 24/ 3/2019 7:31: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.48 41 10.73 464 204 0.20 / 1092.70 6 6
2 1140.52 16 7.95 1948 248 0.45 / 1092.95 6 6
3 1798.60 91 6.44 2893 1695 2.15 / 1094.65 6 6
4 1792.00 51 6.48 2879 951 3.10 / 1095.60 6 6
5 1168.28 45 7.83 2005 706 3.81 / 1096.31 6 6
6 654.88 45 9.05 1305 531 4.34 / 1096.84 6 6
7 110.84 45 10.43 515 242 4.58 / 1097.08 6 6
8 55.88 45 10.64 414 198 4.78 / 1097.28 6 6
9 -0.08 170 10.80 326 599 5.38 / 1097.88 6 10
Average= 5.08 (KJ/cycle)

Cycle 214 GMT 23/ 3/2019 3:17: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.12 41 10.73 446 196 0.20 / 1088.67 6 6
2 960.20 -1 10.73 446 0. 0.00 / 1088.67 6 6
3 1020.48 1 8.62 1732 15 0.21 / 1088.69 6 6
4 1173.52 91 7.80 1985 1409 1.62 / 1090.10 6 6
5 1178.24 51 7.90 2007 809 2.43 / 1090.91 6 6
6 764.28 45 8.82 1441 572 3.00 / 1091.48 6 6
7 105.48 45 10.49 494 233 3.23 / 1091.71 6 6
8 57.92 45 10.65 410 196 3.43 / 1091.91 6 6
9 -0.12 170 10.83 322 593 4.02 / 1092.50 6 8
Average= 5.08 (KJ/cycle)

Cycle 213 GMT 13/ 3/2019 8:19: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.16 41 10.73 446 196 0.20 / 1084.98 6 6
2 1145.48 91 7.92 1957 1410 1.61 / 1086.39 6 6
3 1148.88 51 8.05 1966 807 2.41 / 1087.19 6 6
4 488.32 45 9.51 1067 457 2.87 / 1087.65 6 6
5 102.36 45 10.52 494 234 3.10 / 1087.88 6 6
6 0.16 170 10.85 322 594 3.70 / 1088.48 6 6
Average= 5.09 (KJ/cycle)

Cycle 212 GMT 3/ 3/2019 13:20: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.24 40 10.79 428 185 0.18 / 1082.36 6 6
2 1015.32 50 8.21 1757 721 0.91 / 1083.08 6 6
3 893.56 45 8.56 1616 622 1.53 / 1083.70 6 6
4 182.00 45 10.25 635 293 1.82 / 1083.99 6 6
5 45.96 45 10.69 399 192 2.01 / 1084.19 6 6
6 -0.12 170 10.84 322 593 2.61 / 1084.78 6 9
Average= 5.09 (KJ/cycle)

Cycle 211 GMT 21/ 2/2019 19: 1: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.96 40 10.79 446 192 0.19 / 1076.58 6 6
2 1159.76 10 8.17 1978 162 0.35 / 1076.74 6 6
3 1900.16 30 6.76 3011 611 0.96 / 1077.35 6 6
4 1900.08 90 6.67 3072 1844 2.81 / 1079.19 6 6
5 1891.24 51 6.59 3016 1014 3.82 / 1080.21 6 6
6 1125.88 45 8.26 1918 713 4.54 / 1080.92 6 6
7 454.00 45 9.68 1020 444 4.98 / 1081.37 6 6
8 86.84 45 10.60 463 221 5.20 / 1081.59 6 6
9 0.00 170 10.88 317 586 5.79 / 1082.17 6 7
Average= 5.10 (KJ/cycle)

Cycle 210 GMT 20/ 2/2019 15:24: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.32 40 10.73 464 199 0.20 / 1072.38 6 6
2 1156.36 30 8.04 1963 473 0.67 / 1072.85 6 6
3 1159.20 91 8.16 2005 1489 2.16 / 1074.34 6 6
4 1160.16 51 8.17 1998 833 2.99 / 1075.17 6 6
5 352.24 45 9.92 875 391 3.38 / 1075.56 6 6
6 96.04 45 10.57 484 230 3.61 / 1075.79 6 6
7 0.16 170 10.87 321 593 4.21 / 1076.39 6 6
Average= 5.10 (KJ/cycle)

Cycle 209 GMT 10/ 2/2019 20:25: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.84 40 10.79 446 192 0.19 / 1068.11 6 6
2 1149.84 30 8.09 1960 476 0.67 / 1068.58 6 6
3 1153.04 91 8.26 1992 1497 2.17 / 1070.08 6 6
4 1154.68 51 8.31 1980 839 3.00 / 1070.92 6 6
5 445.16 45 9.73 1016 445 3.45 / 1071.36 6 6
6 82.36 45 10.63 463 221 3.67 / 1071.59 6 6
7 0.04 170 10.88 320 592 4.26 / 1072.18 6 6
Average= 5.11 (KJ/cycle)

Cycle 208 GMT 1/ 2/2019 1:27: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.48 40 10.86 446 194 0.19 / 1065.51 6 6
2 1001.80 50 8.42 1767 744 0.94 / 1066.26 6 6
3 883.60 45 8.81 1609 638 1.58 / 1066.90 6 6
4 123.60 45 10.56 519 247 1.82 / 1067.14 6 6
5 68.64 45 10.70 426 205 2.03 / 1067.35 6 6
6 0.00 170 10.91 306 568 2.59 / 1067.91 6 8
Average= 5.11 (KJ/cycle)

Cycle 207 GMT 22/ 1/2019 7: 8: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.40 38 10.79 446 183 0.18 / 1059.60 6 6
2 1079.52 2 8.49 1928 33 0.22 / 1059.63 6 6
3 1032.20 1 8.94 1750 16 0.23 / 1059.64 6 6
4 1164.56 10 8.36 1999 167 0.40 / 1059.81 6 6
5 1898.48 30 6.87 3074 634 1.03 / 1060.44 6 6
6 1898.12 90 6.92 3049 1899 2.93 / 1062.34 6 6
7 1888.80 51 6.73 3021 1037 3.97 / 1063.38 6 6
8 1057.32 45 8.49 1860 711 4.68 / 1064.09 6 6
9 368.08 45 9.97 900 404 5.08 / 1064.49 6 6
10 98.52 45 10.62 484 231 5.31 / 1064.73 6 6
11 -0.04 170 10.89 321 594 5.91 / 1065.32 6 6
Average= 5.12 (KJ/cycle)

Cycle 206 GMT 21/ 1/2019 2:55: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.12 41 10.79 464 205 0.21 / 1055.38 6 6
2 971.60 -1 10.79 464 0. 0.00 / 1055.38 6 6
3 1020.00 1 9.07 1803 16 0.22 / 1055.39 6 6
4 1167.04 30 8.22 1969 486 0.71 / 1055.88 6 6
5 1170.16 91 8.35 1994 1515 2.22 / 1057.39 6 6
6 1171.16 50 8.36 1991 832 3.05 / 1058.22 6 6
7 363.88 44 9.99 893 393 3.45 / 1058.62 6 6
8 100.20 44 10.62 483 226 3.67 / 1058.84 6 6
9 0.04 170 10.91 307 569 4.24 / 1059.41 6 6
Average= 5.12 (KJ/cycle)

Cycle 205 GMT 11/ 1/2019 7:56: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.64 39 10.79 464 195 0.20 / 1051.06 6 6
2 1041.36 1 8.81 1839 16 0.21 / 1051.08 6 6
3 1036.68 1 8.88 1767 16 0.23 / 1051.09 6 6
4 1179.84 30 8.28 1972 490 0.72 / 1051.58 6 6
5 1182.76 91 8.42 2017 1545 2.26 / 1053.13 6 6
6 1182.52 51 8.40 1997 856 3.12 / 1053.98 6 6
7 325.92 45 10.07 843 382 3.50 / 1054.37 6 6
8 94.36 45 10.63 469 224 3.72 / 1054.59 6 6
9 0.04 170 10.90 313 580 4.30 / 1055.17 6 6
Average= 5.12 (KJ/cycle)

Cycle 204 GMT 1/ 1/2019 13: 2: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.44 38 10.98 464 194 0.19 / 1048.33 6 6
2 1057.96 1 9.13 1892 17 0.21 / 1048.35 6 6
3 1034.12 1 8.94 1875 17 0.23 / 1048.37 6 6
4 1034.64 91 8.77 1808 1443 1.67 / 1049.81 6 6
5 186.28 45 10.40 634 297 1.97 / 1050.11 6 6
6 46.16 45 10.81 383 186 2.15 / 1050.29 6 6
7 -0.08 170 10.91 308 571 2.72 / 1050.87 6 8
Average= 5.13 (KJ/cycle)

Cycle 203 GMT 22/12/2018 18:40: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.20 36 11.05 446 177 0.18 / 1042.54 6 6
2 1028.24 1 9.20 1803 17 0.19 / 1042.56 6 6
3 1025.28 1 9.13 1750 16 0.21 / 1042.57 6 6
4 1165.00 8 8.70 1986 138 0.35 / 1042.71 6 6
5 1900.60 21 7.08 3084 459 0.81 / 1043.17 6 6
6 1900.88 60 7.07 3057 1297 2.10 / 1044.47 6 6
7 1891.52 91 6.67 3037 1843 3.95 / 1046.31 6 6
8 931.92 45 8.89 1693 677 4.62 / 1046.99 6 6
9 266.00 45 10.29 761 352 4.98 / 1047.34 6 6
10 82.88 45 10.79 449 218 5.19 / 1047.56 6 6
11 0.04 170 11.02 312 585 5.78 / 1048.14 6 9
Average= 5.14 (KJ/cycle)

Cycle 202 GMT 21/12/2018 15:25: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.00 40 11.18 446 199 0.20 / 1039.83 6 6
2 967.40 -1 11.18 446 0. 0.00 / 1039.83 6 6
3 1023.04 1 9.20 1785 16 0.22 / 1039.85 6 6
4 1018.64 91 8.66 1800 1419 1.63 / 1041.27 6 6
5 191.00 45 10.55 645 306 1.94 / 1041.57 6 6
6 57.80 45 10.98 399 197 2.14 / 1041.77 6 6
7 0.00 170 11.13 313 592 2.73 / 1042.36 6 8
Average= 5.13 (KJ/cycle)

Cycle 201 GMT 11/12/2018 21:13: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.28 31 11.37 446 157 0.16 / 1036.91 6 6
2 1046.88 4 9.58 1892 73 0.23 / 1036.99 6 6
3 1109.16 3 9.32 1910 53 0.28 / 1037.04 6 6
4 1072.00 2 9.52 1821 35 0.32 / 1037.08 6 6
5 1046.68 91 8.88 1819 1470 1.79 / 1038.55 6 6
6 181.28 45 10.61 619 296 2.08 / 1038.84 6 6
7 53.44 45 11.02 390 193 2.28 / 1039.03 6 6
8 -0.08 170 11.13 316 598 2.87 / 1039.63 6 8
Average= 5.15 (KJ/cycle)

Cycle 200 GMT 2/12/2018 5:11: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.72 31 11.81 464 170 0.17 / 1034.00 6 6
2 1006.24 4 10.54 1857 78 0.25 / 1034.08 6 6
3 1065.76 2 10.66 1875 40 0.29 / 1034.12 6 6
4 1034.12 1 10.47 1910 20 0.31 / 1034.14 6 6
5 1026.20 91 9.45 1824 1569 1.88 / 1035.70 6 6
6 139.56 45 11.14 557 279 2.16 / 1035.98 6 6
7 40.08 45 11.42 371 191 2.35 / 1036.17 6 6
8 0.00 170 11.41 301 584 2.93 / 1036.76 6 9
Average= 5.16 (KJ/cycle)

Cycle 199 GMT 22/11/2018 11: 7: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.40 31 12.31 464 177 0.18 / 1028.00 6 6
2 1050.16 3 11.18 1839 62 0.24 / 1028.06 6 6
3 1069.24 2 10.79 1892 41 0.28 / 1028.10 6 6
4 1030.60 1 10.47 1875 20 0.30 / 1028.12 6 6
5 1155.36 7 10.22 2077 149 0.45 / 1028.27 6 6
6 1861.16 51 8.60 2959 1298 1.75 / 1029.56 6 6
7 1858.76 60 7.57 2937 1334 3.08 / 1030.90 6 6
8 1841.68 75 6.90 2920 1511 4.59 / 1032.41 6 6
9 498.24 45 10.57 1109 527 5.12 / 1032.94 6 6
10 87.12 45 11.46 478 247 5.36 / 1033.18 6 6
11 -0.04 170 11.69 324 644 6.01 / 1033.83 6 7
Average= 5.17 (KJ/cycle)

Cycle 198 GMT 21/11/2018 7:26:58

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.84 31 13.21 446 183 0.18 / 1023.34 6 6
2 1152.76 51 8.04 1960 804 0.99 / 1024.14 6 6
3 1157.48 61 7.10 1965 851 1.84 / 1024.99 6 6
4 1160.16 75 7.34 1972 1086 2.92 / 1026.08 6 6
5 656.80 45 10.27 1326 613 3.54 / 1026.69 6 6
6 103.20 45 11.76 514 272 3.81 / 1026.96 6 6
7 10.80 45 12.08 342 186 3.99 / 1027.15 6 6
8 -0.04 170 11.89 331 669 4.66 / 1027.82 6 14
Average= 5.16 (KJ/cycle)

Cycle 197 GMT 11/11/2018 12:27: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.20 31 13.40 464 193 0.19 / 1018.52 6 6
2 1143.36 51 7.42 1932 731 0.92 / 1019.25 6 6
3 1148.12 61 6.74 1909 785 1.71 / 1020.03 6 6
4 1154.24 75 7.23 1954 1060 2.77 / 1021.09 6 6
5 1034.72 44 9.38 1817 750 3.52 / 1021.84 6 6
6 182.60 45 12.17 649 355 3.87 / 1022.20 6 6
7 47.12 45 12.80 407 234 4.11 / 1022.43 6 6
8 -0.04 170 12.61 338 725 4.83 / 1023.16 6 14
Average= 5.17 (KJ/cycle)

Cycle 196 GMT 1/11/2018 17:27: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.92 31 13.65 482 204 0.20 / 1015.62 6 6
2 1016.52 75 8.83 1795 1189 1.39 / 1016.81 6 6
3 344.72 45 12.10 887 483 1.88 / 1017.29 6 6
4 88.64 45 12.93 482 280 2.16 / 1017.57 6 6
5 0.04 170 13.08 338 752 2.91 / 1018.32 6 13
Average= 5.17 (KJ/cycle)

Cycle 195 GMT 22/10/2018 23:18: 3

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.44 30 14.04 482 203 0.20 / 1009.20 6 6
2 1136.00 7 10.96 2005 154 0.36 / 1009.35 6 6
3 1862.28 51 8.83 2977 1341 1.70 / 1010.69 6 6
4 1860.00 60 7.92 2982 1417 3.11 / 1012.11 6 6
5 1843.36 75 8.69 2916 1901 5.02 / 1014.01 6 6
6 178.80 45 12.79 662 381 5.40 / 1014.39 6 6
7 47.44 45 13.28 419 250 5.65 / 1014.64 6 6
8 0.00 170 13.22 345 775 6.42 / 1015.42 6 16
Average= 5.18 (KJ/cycle)

Cycle 194 GMT 21/10/2018 19:46: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.96 28 14.10 482 190 0.19 / 1003.96 6 6
2 1103.68 3 11.94 1964 70 0.26 / 1004.03 6 6
3 1043.88 1 11.37 1892 22 0.28 / 1004.05 6 6
4 1185.32 51 7.03 1910 685 0.97 / 1004.74 6 6
5 1190.88 61 7.07 2009 866 1.83 / 1005.60 6 6
6 1198.00 75 8.00 2034 1220 3.05 / 1006.82 6 6
7 936.68 45 10.27 1712 791 3.84 / 1007.62 6 6
8 113.36 45 13.52 538 327 4.17 / 1007.94 6 6
9 27.00 45 13.92 387 242 4.41 / 1008.19 6 6
10 0.00 170 13.66 348 808 5.22 / 1008.99 6 22
Average= 5.17 (KJ/cycle)

Cycle 193 GMT 12/10/2018 1:34: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.20 29 14.17 464 191 0.19 / 999.06 6 6
2 970.88 -1 14.17 464 0. 0.00 / 999.06 6 6
3 1161.48 51 7.38 1948 733 0.92 / 999.80 6 6
4 1166.96 61 7.46 1975 899 1.82 / 1000.69 6 6
5 1171.88 75 8.49 1977 1259 3.08 / 1001.95 6 6
6 634.20 45 11.95 1310 704 3.79 / 1002.66 6 6
7 85.24 45 13.75 488 302 4.09 / 1002.96 6 6
8 0.00 170 13.86 344 811 4.90 / 1003.77 6 12
Average= 5.17 (KJ/cycle)

Cycle 192 GMT 2/10/2018 6:45: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.64 31 14.23 482 213 0.21 / 995.99 6 6
2 1000.00 90 9.29 1759 1471 1.68 / 997.46 6 6
3 161.80 45 13.67 594 365 2.05 / 997.83 6 6
4 17.64 45 14.19 356 227 2.28 / 998.06 6 6
5 0.04 170 14.07 341 816 3.09 / 998.87 6 20
Average= 5.18 (KJ/cycle)

Cycle 191 GMT 22/ 9/2018 12:37: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.12 27 14.23 482 185 0.19 / 989.01 6 6
2 1023.28 3 12.12 1857 68 0.25 / 989.07 6 6
3 1142.24 7 10.66 2017 151 0.40 / 989.23 6 6
4 1900.80 51 8.71 3048 1354 1.76 / 990.58 6 6
5 1899.20 60 8.46 3042 1544 3.30 / 992.12 6 6
6 1883.48 90 9.15 3011 2480 5.78 / 994.60 6 6
7 143.20 45 13.85 578 360 6.14 / 994.96 6 6
8 0.12 170 14.19 339 818 6.96 / 995.78 6 9
Average= 5.19 (KJ/cycle)

Cycle 190 GMT 21/ 9/2018 9:28: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.16 29 14.23 482 199 0.20 / 984.00 6 6
2 1148.04 51 7.77 1928 764 0.96 / 984.76 6 6
3 1152.52 61 8.02 1975 966 1.93 / 985.73 6 6
4 1153.56 91 9.08 1970 1628 3.56 / 987.35 6 6
5 175.48 45 13.70 635 391 3.95 / 987.74 6 6
6 4.20 45 14.27 341 219 4.17 / 987.96 6 6
7 0.08 170 14.22 355 858 5.03 / 988.82 6 20
Average= 5.18 (KJ/cycle)

Cycle 189 GMT 11/ 9/2018 14:33: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.24 28 14.23 482 192 0.19 / 978.82 6 6
2 1165.68 51 8.09 1951 805 1.00 / 979.63 6 6
3 1170.60 61 8.30 1995 1010 2.01 / 980.64 6 6
4 1171.40 91 9.12 2017 1674 3.68 / 982.31 6 6
5 151.40 45 13.75 609 377 4.06 / 982.69 6 6
6 35.40 45 14.18 400 255 4.31 / 982.94 6 6
7 0.08 170 14.22 353 853 5.17 / 983.80 6 25
Average= 5.18 (KJ/cycle)

Cycle 188 GMT 1/ 9/2018 19:43: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.80 31 14.29 482 214 0.21 / 975.61 6 6
2 997.20 91 9.38 1787 1525 1.74 / 977.14 6 6
3 144.04 45 13.78 606 376 2.11 / 977.52 6 6
4 38.24 45 14.15 410 261 2.38 / 977.78 6 6
5 0.00 170 14.21 353 853 3.23 / 978.63 6 28
Average= 5.18 (KJ/cycle)

Cycle 187 GMT 23/ 8/2018 1:40: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.36 31 14.29 464 206 0.21 / 968.47 6 6
2 875.96 -2 14.29 464 0. 0.00 / 968.47 6 6
3 955.48 -1 14.29 464 0. 0.00 / 968.47 6 6
4 1142.76 7 10.76 2017 152 0.36 / 968.62 6 6
5 1884.88 51 9.13 3036 1414 1.77 / 970.04 6 6
6 1882.60 60 8.86 3017 1604 3.37 / 971.64 6 6
7 1864.92 91 9.58 2968 2587 5.96 / 974.23 6 6
8 96.64 45 13.98 515 324 6.29 / 974.55 6 6
9 0.08 170 14.24 351 850 7.14 / 975.40 6 13
Average= 5.19 (KJ/cycle)

Cycle 186 GMT 21/ 8/2018 22:40: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.52 28 14.29 482 193 0.19 / 963.27 6 6
2 1155.28 51 7.96 1950 792 0.98 / 964.06 6 6
3 1159.48 61 8.32 1983 1006 1.99 / 965.07 6 6
4 1158.68 91 9.50 1997 1726 3.72 / 966.80 6 6
5 123.72 45 13.86 564 352 4.07 / 967.15 6 6
6 31.76 45 14.18 395 252 4.32 / 967.40 6 6
7 0.08 170 14.24 357 864 5.19 / 968.27 6 27
Average= 5.18 (KJ/cycle)

Cycle 185 GMT 12/ 8/2018 3:58: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.12 31 14.29 482 214 0.21 / 957.98 6 6
2 916.92 -2 14.29 482 0. 0.00 / 957.98 6 6
3 1178.12 51 8.11 2004 829 1.04 / 958.81 6 6
4 1182.76 61 8.58 2030 1062 2.10 / 959.87 6 6
5 1181.52 91 9.50 2026 1751 3.86 / 961.62 6 6
6 112.92 45 13.89 556 348 4.20 / 961.97 6 6
7 27.72 45 14.16 394 251 4.45 / 962.22 6 6
8 -0.04 170 14.21 357 862 5.32 / 963.08 6 32
Average= 5.18 (KJ/cycle)

Cycle 184 GMT 2/ 8/2018 9:18: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.20 31 14.29 482 214 0.21 / 954.77 6 6
2 1004.16 91 9.36 1772 1509 1.72 / 956.28 6 6
3 136.12 45 13.83 596 371 2.09 / 956.65 6 6
4 27.32 45 14.15 395 252 2.35 / 956.90 6 6
5 0.00 170 14.22 355 858 3.20 / 957.76 6 30
Average= 5.18 (KJ/cycle)

Cycle 183 GMT 23/ 7/2018 15:15: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.12 31 14.23 482 213 0.21 / 947.59 6 6
2 1125.24 7 11.02 2011 155 0.37 / 947.74 6 6
3 1860.44 51 9.28 3006 1423 1.79 / 949.17 6 6
4 1858.40 60 9.18 2954 1627 3.42 / 950.79 6 6
5 1842.16 91 9.68 2965 2612 6.03 / 953.41 6 6
6 76.76 45 14.04 478 302 6.33 / 953.71 6 6
7 0.00 170 14.24 352 852 7.18 / 954.56 6 17
Average= 5.19 (KJ/cycle)

Cycle 182 GMT 22/ 7/2018 12:16: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.64 31 14.23 482 213 0.21 / 942.61 6 6
2 1156.56 51 7.91 1928 778 0.99 / 943.39 6 6
3 1161.80 61 8.58 1979 1036 2.03 / 944.42 6 6
4 1162.16 91 9.66 2001 1759 3.79 / 946.18 6 6
5 107.40 45 13.89 542 339 4.12 / 946.52 6 6
6 0.12 170 14.23 354 856 4.98 / 947.38 6 16
Average= 5.18 (KJ/cycle)

Cycle 181 GMT 12/ 7/2018 17:33: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.20 31 14.29 482 214 0.21 / 937.67 6 6
2 1133.88 51 8.37 1917 818 1.03 / 938.48 6 6
3 1138.76 61 8.73 1964 1046 2.08 / 939.53 6 6
4 1138.28 91 9.68 1961 1727 3.81 / 941.26 6 6
5 94.12 45 13.92 517 324 4.13 / 941.58 6 6
6 0.12 170 14.25 336 814 4.94 / 942.40 6 20
Average= 5.18 (KJ/cycle)

Cycle 180 GMT 2/ 7/2018 22:59: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.24 31 14.23 482 213 0.21 / 934.75 6 6
2 994.64 91 9.20 1770 1482 1.69 / 936.23 6 6
3 125.08 45 13.87 576 360 2.05 / 936.59 6 6
4 0.04 170 14.18 357 861 2.91 / 937.45 6 12
Average= 5.18 (KJ/cycle)

Cycle 179 GMT 23/ 6/2018 5: 1: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.68 31 14.23 500 221 0.22 / 927.46 6 6
2 1129.32 7 10.85 1999 152 0.37 / 927.61 6 6
3 1852.60 51 9.33 2994 1425 1.80 / 929.04 6 6
4 1850.48 60 9.22 2977 1647 3.44 / 930.68 6 6
5 1833.48 91 9.80 2962 2642 6.09 / 933.33 6 6
6 93.80 45 13.93 529 332 6.42 / 933.66 6 6
7 0.00 170 14.18 365 880 7.30 / 934.54 6 20
Average= 5.19 (KJ/cycle)

Cycle 178 GMT 22/ 6/2018 2:13: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.76 30 14.29 482 207 0.21 / 922.44 6 6
2 1023.08 1 11.30 1875 21 0.23 / 922.46 6 6
3 1164.24 51 7.46 1945 740 0.97 / 923.20 6 6
4 1169.60 61 8.45 2021 1042 2.01 / 924.24 6 6
5 1171.40 91 9.69 2024 1785 3.79 / 926.03 6 6
6 106.80 45 13.87 560 350 4.14 / 926.38 6 6
7 0.00 170 14.20 358 864 5.01 / 927.24 6 15
Average= 5.18 (KJ/cycle)

Cycle 177 GMT 12/ 6/2018 7:33: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.12 31 14.29 482 214 0.21 / 917.40 6 6
2 954.52 -1 14.29 482 0. 0.00 / 917.40 6 6
3 1170.00 51 7.68 1948 763 0.98 / 918.17 6 6
4 1175.08 61 8.67 2012 1064 2.04 / 919.23 6 6
5 1176.56 91 9.66 2033 1787 3.83 / 921.02 6 6
6 108.16 45 13.88 562 351 4.18 / 921.37 6 6
7 0.04 170 14.22 358 865 5.04 / 922.23 6 17
Average= 5.18 (KJ/cycle)

Cycle 176 GMT 2/ 6/2018 12:52: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.32 30 14.29 482 207 0.21 / 914.18 6 6
2 1038.40 1 12.25 1892 23 0.23 / 914.20 6 6
3 1021.40 91 8.80 1800 1441 1.67 / 915.64 6 6
4 159.16 45 13.75 656 406 2.08 / 916.05 6 6
5 36.20 45 14.10 414 263 2.34 / 916.31 6 6
6 -0.08 170 14.20 363 876 3.22 / 917.19 6 23
Average= 5.18 (KJ/cycle)

Cycle 175 GMT 23/ 5/2018 18:45: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.40 31 14.23 482 213 0.21 / 907.30 6 6
2 1129.24 7 10.81 1982 150 0.36 / 907.45 6 6
3 1848.84 100 9.06 2995 2713 3.08 / 910.16 6 6
4 1831.24 91 9.85 2963 2656 5.73 / 912.81 6 6
5 87.96 45 14.00 504 318 6.05 / 913.13 6 6
6 0.08 170 14.25 347 841 6.89 / 913.97 6 17
Average= 5.19 (KJ/cycle)

Cycle 174 GMT 22/ 5/2018 15:44: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.84 28 14.23 482 192 0.19 / 902.55 6 6
2 1081.88 2 11.88 1946 46 0.24 / 902.60 6 6
3 1039.88 1 11.56 1892 22 0.26 / 902.62 6 6
4 1171.96 101 7.49 1968 1489 1.75 / 904.11 6 6
5 1172.00 91 9.72 2036 1801 3.55 / 905.91 6 6
6 85.28 45 13.96 501 315 3.86 / 906.23 6 6
7 0.00 170 14.20 355 857 4.72 / 907.08 6 12
Average= 5.18 (KJ/cycle)

Cycle 173 GMT 12/ 5/2018 21:14: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.96 32 14.29 464 212 0.21 / 897.84 6 6
2 866.12 -3 14.29 464 0. 0.00 / 897.84 6 6
3 1145.92 101 7.75 1953 1529 1.74 / 899.37 6 6
4 1144.24 91 9.81 1986 1773 3.51 / 901.15 6 6
5 102.68 45 13.89 537 336 3.85 / 901.48 6 6
6 0.04 170 14.19 365 880 4.73 / 902.36 6 14
Average= 5.19 (KJ/cycle)

Cycle 172 GMT 3/ 5/2018 2:59: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.08 31 14.29 464 206 0.21 / 894.75 6 6
2 938.76 -1 14.29 464 0. 0.00 / 894.75 6 6
3 987.36 91 8.69 1758 1390 1.60 / 896.14 6 6
4 154.00 45 13.80 636 395 1.99 / 896.54 6 6
5 4.44 45 14.19 360 230 2.22 / 896.77 6 6
6 0.04 170 14.23 357 864 3.08 / 897.63 6 24
Average= 5.19 (KJ/cycle)

Cycle 171 GMT 23/ 4/2018 8:52: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.04 31 14.17 500 220 0.22 / 887.82 6 6
2 1128.52 7 10.58 2029 150 0.37 / 887.97 6 6
3 1862.40 100 8.98 3002 2696 3.07 / 890.67 6 6
4 1845.48 91 9.88 2980 2679 5.74 / 893.35 6 6
5 109.36 45 13.98 535 337 6.08 / 893.69 6 6
6 0.12 170 14.23 356 861 6.94 / 894.55 6 15
Average= 5.20 (KJ/cycle)

Cycle 170 GMT 22/ 4/2018 5:45: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.00 29 14.23 482 199 0.20 / 883.12 6 6
2 1011.04 3 11.94 1892 68 0.27 / 883.19 6 6
3 1158.04 101 7.10 1942 1393 1.66 / 884.58 6 6
4 1159.72 91 9.69 2028 1788 3.45 / 886.37 6 6
5 142.28 45 13.81 603 375 3.82 / 886.75 6 6
6 0.08 170 14.21 355 858 4.68 / 887.60 6 12
Average= 5.19 (KJ/cycle)

Cycle 169 GMT 12/ 4/2018 11:25: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.80 30 14.23 482 206 0.21 / 878.51 6 6
2 945.92 -1 14.23 482 0. 0.00 / 878.51 6 6
3 1143.92 101 7.31 1942 1434 1.64 / 879.94 6 6
4 1144.16 91 9.66 1994 1753 3.39 / 881.70 6 6
5 143.72 45 13.82 596 371 3.76 / 882.07 6 6
6 0.00 170 14.20 355 857 4.62 / 882.92 6 13
Average= 5.19 (KJ/cycle)

Cycle 168 GMT 2/ 4/2018 17: 1: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.20 30 14.23 482 206 0.21 / 875.30 6 6
2 1011.20 91 8.33 1792 1358 1.56 / 876.66 6 6
3 296.48 45 13.48 860 522 2.09 / 877.18 6 6
4 31.92 45 14.13 405 258 2.34 / 877.44 6 6
5 -0.04 170 14.22 357 863 3.21 / 878.30 6 21
Average= 5.20 (KJ/cycle)

Cycle 167 GMT 23/ 3/2018 22:57: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.08 31 14.10 500 219 0.22 / 868.40 6 6
2 1132.48 7 10.45 2017 148 0.37 / 868.55 6 6
3 1866.32 100 8.85 3004 2659 3.02 / 871.21 6 6
4 1852.44 91 9.85 2983 2674 5.70 / 873.88 6 6
5 115.72 45 13.91 560 351 6.05 / 874.23 6 6
6 -0.04 170 14.22 358 865 6.91 / 875.10 6 12
Average= 5.21 (KJ/cycle)

Cycle 166 GMT 22/ 3/2018 19:43: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.32 29 14.17 482 198 0.20 / 863.91 6 6
2 1024.04 1 9.52 1857 18 0.22 / 863.93 6 6
3 1153.36 101 6.69 1930 1304 1.52 / 865.23 6 6
4 1156.80 91 9.54 1993 1730 3.25 / 866.96 6 6
5 130.80 45 13.88 574 359 3.61 / 867.32 6 6
6 0.12 170 14.22 356 861 4.47 / 868.18 6 12
Average= 5.20 (KJ/cycle)

Cycle 165 GMT 13/ 3/2018 1: 1: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.48 30 14.23 482 206 0.21 / 860.65 6 6
2 1021.36 91 8.09 1784 1313 1.52 / 861.96 6 6
3 462.08 45 13.14 1100 650 2.17 / 862.61 6 6
4 29.40 45 14.14 386 246 2.42 / 862.86 6 6
5 0.00 170 14.22 354 856 3.27 / 863.71 6 26
Average= 5.20 (KJ/cycle)

Cycle 164 GMT 3/ 3/2018 6:58: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.64 31 14.23 482 213 0.21 / 853.81 6 6
2 1133.32 7 10.60 1976 147 0.36 / 853.96 6 6
3 1875.12 100 8.68 3001 2605 2.96 / 856.56 6 6
4 1858.84 91 9.85 2986 2677 5.64 / 859.24 6 6
5 125.92 45 13.93 550 345 5.99 / 859.58 6 6
6 0.20 170 14.23 356 861 6.85 / 860.44 6 15
Average= 5.21 (KJ/cycle)

Cycle 163 GMT 2/ 3/2018 3:43: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.16 31 14.17 500 220 0.22 / 849.44 6 6
2 941.68 -1 14.17 500 0. 0.00 / 849.44 6 6
3 1144.04 101 6.52 1896 1249 1.47 / 850.68 6 6
4 1149.88 91 9.43 1988 1706 3.17 / 852.39 6 6
5 137.60 45 13.82 588 366 3.54 / 852.76 6 6
6 -0.08 170 14.21 348 841 4.38 / 853.60 6 10
Average= 5.20 (KJ/cycle)

Cycle 162 GMT 20/ 2/2018 9: 1: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.64 31 14.17 500 220 0.22 / 846.15 6 6
2 949.08 -1 14.17 500 0. 0.00 / 846.15 6 6
3 1013.40 91 7.85 1767 1262 1.48 / 847.42 6 6
4 458.12 45 13.11 1107 653 2.13 / 848.07 6 6
5 60.40 45 14.02 453 286 2.42 / 848.36 6 6
6 0.04 170 14.18 357 861 3.28 / 849.22 6 24
Average= 5.21 (KJ/cycle)

Cycle 161 GMT 10/ 2/2018 15: 1: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.56 30 14.10 500 211 0.21 / 839.29 6 6
2 1158.24 7 10.53 2029 150 0.36 / 839.44 6 6
3 1862.32 100 8.73 2991 2611 2.97 / 842.05 6 6
4 1846.08 91 9.85 2995 2685 5.66 / 844.74 6 6
5 111.20 45 13.93 537 337 5.99 / 845.08 6 6
6 0.00 170 14.21 356 860 6.85 / 845.94 6 14
Average= 5.22 (KJ/cycle)

Cycle 160 GMT 9/ 2/2018 11:53: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.12 31 14.10 482 211 0.21 / 834.89 6 6
2 1138.08 101 6.58 1907 1267 1.48 / 836.16 6 6
3 1143.76 91 9.40 1987 1700 3.18 / 837.85 6 6
4 137.32 45 13.82 596 371 3.55 / 838.23 6 6
5 0.12 170 14.19 355 856 4.40 / 839.08 6 14
Average= 5.21 (KJ/cycle)

Cycle 159 GMT 30/ 1/2018 17: 8: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.80 27 14.17 482 184 0.18 / 831.67 6 6
2 1031.20 3 12.44 1875 70 0.25 / 831.74 6 6
3 1024.68 1 11.56 1875 22 0.28 / 831.76 6 6
4 1013.96 91 7.69 1758 1230 1.51 / 832.99 6 6
5 362.64 45 13.31 960 575 2.08 / 833.57 6 6
6 26.44 45 14.12 392 249 2.33 / 833.82 6 6
7 -0.04 170 14.20 357 862 3.19 / 834.68 6 21
Average= 5.22 (KJ/cycle)

Cycle 158 GMT 20/ 1/2018 23: 3: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.20 30 14.10 500 211 0.21 / 824.87 6 6
2 1144.12 7 10.30 2053 148 0.36 / 825.02 6 6
3 1858.20 100 8.58 2999 2573 2.93 / 827.59 6 6
4 1841.20 91 9.88 2978 2677 5.61 / 830.27 6 6
5 123.40 45 13.93 557 349 5.96 / 830.62 6 6
6 0.00 170 14.19 360 868 6.83 / 831.48 6 13
Average= 5.23 (KJ/cycle)

Cycle 157 GMT 19/ 1/2018 19:50: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.72 31 14.17 500 220 0.22 / 820.33 6 6
2 1143.16 101 6.09 1886 1160 1.38 / 821.49 6 6
3 1150.12 91 9.11 1999 1657 3.04 / 823.15 6 6
4 155.20 45 13.69 635 391 3.43 / 823.54 6 6
5 35.60 45 14.04 413 261 3.69 / 823.80 6 6
6 0.04 170 14.15 357 859 4.55 / 824.66 6 18
Average= 5.22 (KJ/cycle)

Cycle 156 GMT 10/ 1/2018 0:58: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.04 31 14.10 500 219 0.22 / 817.09 6 6
2 880.76 -2 14.10 500 0. 0.00 / 817.09 6 6
3 958.80 -1 14.10 500 0. 0.00 / 817.09 6 6
4 1006.24 91 7.41 1750 1180 1.40 / 818.27 6 6
5 479.52 45 13.08 1130 665 2.06 / 818.93 6 6
6 78.36 45 13.95 493 309 2.37 / 819.24 6 6
7 -0.04 170 14.13 361 867 3.24 / 820.11 6 21
Average= 5.22 (KJ/cycle)

Cycle 155 GMT 31/12/2017 6:54: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.80 31 14.17 482 212 0.21 / 810.02 6 6
2 965.52 -1 14.17 482 0. 0.00 / 810.02 6 6
3 1161.24 7 10.45 1999 146 0.36 / 810.16 6 6
4 1865.40 100 8.55 3002 2567 2.92 / 812.73 6 6
5 1849.32 91 9.89 2988 2689 5.61 / 815.42 6 6
6 122.56 45 13.89 562 351 5.97 / 815.77 6 6
7 8.16 45 14.14 365 232 6.20 / 816.00 6 6
8 0.04 170 14.22 358 865 7.06 / 816.87 6 30
Average= 5.24 (KJ/cycle)

Cycle 154 GMT 30/12/2017 3:38: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.40 31 14.10 500 219 0.22 / 805.37 6 6
2 1141.84 101 5.91 1871 1117 1.34 / 806.49 6 6
3 1147.28 91 9.03 1998 1642 2.98 / 808.13 6 6
4 286.28 45 13.42 841 508 3.49 / 808.64 6 6
5 64.48 45 13.95 464 291 3.78 / 808.93 6 6
6 -0.08 170 14.14 365 877 4.65 / 809.81 6 22
Average= 5.22 (KJ/cycle)

Cycle 153 GMT 20/12/2017 8:54: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.08 31 14.10 500 219 0.22 / 802.16 6 6
2 1002.92 91 7.25 1735 1145 1.36 / 803.30 6 6
3 488.20 45 13.07 1134 667 2.03 / 803.97 6 6
4 75.36 45 13.92 484 303 2.33 / 804.27 6 6
5 0.56 171 14.12 364 879 3.21 / 805.15 6 16
Average= 5.23 (KJ/cycle)

Cycle 152 GMT 10/12/2017 14:47: 3

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.04 31 14.10 500 219 0.22 / 795.25 6 6
2 1136.88 7 10.45 2005 147 0.37 / 795.40 6 6
3 1882.72 100 8.49 3055 2594 2.96 / 797.99 6 6
4 1868.52 91 9.93 3005 2715 5.67 / 800.70 6 6
5 137.68 45 13.82 597 371 6.05 / 801.08 6 6
6 0.04 170 14.21 358 865 6.91 / 801.94 6 12
Average= 5.24 (KJ/cycle)

Cycle 151 GMT 9/12/2017 11:26: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.40 32 14.17 482 219 0.22 / 790.57 6 6
2 972.28 -1 14.17 482 0. 0.00 / 790.57 6 6
3 1150.56 101 5.89 1871 1113 1.33 / 791.68 6 6
4 1159.96 91 9.01 2016 1653 2.98 / 793.34 6 6
5 298.44 45 13.38 863 520 3.50 / 793.86 6 6
6 73.52 45 13.94 479 300 3.80 / 794.16 6 6
7 0.00 170 14.15 363 873 4.68 / 795.03 6 20
Average= 5.23 (KJ/cycle)

Cycle 150 GMT 29/11/2017 16:38:59

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.68 31 14.17 482 212 0.21 / 787.35 6 6
2 1018.92 91 7.08 1761 1135 1.35 / 788.48 6 6
3 508.52 45 13.01 1164 681 2.03 / 789.16 6 6
4 96.80 45 13.89 522 326 2.35 / 789.49 6 6
5 0.04 170 14.15 359 864 3.22 / 790.35 6 21
Average= 5.23 (KJ/cycle)

Cycle 149 GMT 19/11/2017 22:26: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.80 31 14.10 482 211 0.21 / 780.50 6 6
2 1138.00 7 10.60 2035 151 0.36 / 780.65 6 6
3 1854.16 100 8.68 2990 2595 2.96 / 783.25 6 6
4 1837.72 91 9.93 2975 2688 5.65 / 785.94 6 6
5 100.20 45 13.88 534 334 5.98 / 786.27 6 6
6 0.08 170 14.19 358 864 6.84 / 787.13 6 21
Average= 5.25 (KJ/cycle)

Cycle 148 GMT 18/11/2017 19:12: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.36 29 14.10 500 204 0.20 / 775.69 6 6
2 1061.04 2 11.11 1946 43 0.25 / 775.73 6 6
3 1026.68 1 10.60 1857 20 0.27 / 775.75 6 6
4 1166.28 101 5.72 1905 1101 1.37 / 776.85 6 6
5 1173.92 91 8.99 2033 1663 3.03 / 778.52 6 6
6 344.24 45 13.31 930 557 3.59 / 779.08 6 6
7 81.72 45 13.88 511 319 3.91 / 779.39 6 6
8 -0.16 170 14.08 375 898 4.80 / 780.29 6 17
Average= 5.24 (KJ/cycle)

Cycle 147 GMT 9/11/2017 0:22:59

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.24 31 14.10 482 211 0.21 / 772.46 6 6
2 1002.24 91 6.99 1737 1105 1.32 / 773.56 6 6
3 608.64 45 12.78 1315 756 2.07 / 774.32 6 6
4 79.04 45 13.92 486 304 2.38 / 774.62 6 6
5 0.04 170 14.15 360 866 3.24 / 775.49 6 23
Average= 5.24 (KJ/cycle)

Cycle 146 GMT 30/10/2017 6:17: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.24 31 14.10 482 211 0.21 / 765.63 6 6
2 1129.40 4 10.34 1982 82 0.29 / 765.71 6 6
3 1909.12 100 8.33 3080 2566 2.86 / 768.28 6 6
4 1896.52 91 9.83 3061 2738 5.60 / 771.02 6 6
5 155.60 45 13.77 617 382 5.98 / 771.40 6 6
6 0.16 170 14.22 350 846 6.82 / 772.24 6 16
Average= 5.25 (KJ/cycle)

Cycle 145 GMT 29/10/2017 3:56: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.24 29 14.10 446 182 0.18 / 760.96 6 6
2 1142.88 101 5.89 1868 1111 1.29 / 762.07 6 6
3 1150.44 91 8.90 2001 1621 2.91 / 763.69 6 6
4 414.32 45 13.15 1030 610 3.52 / 764.30 6 6
5 46.76 45 14.01 421 265 3.79 / 764.57 6 6
6 -0.04 170 14.17 354 853 4.64 / 765.42 6 24
Average= 5.24 (KJ/cycle)

Cycle 144 GMT 19/10/2017 9:17: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.96 31 14.10 482 211 0.21 / 757.76 6 6
2 1006.56 91 6.97 1748 1109 1.32 / 758.87 6 6
3 614.04 45 12.79 1300 748 2.07 / 759.62 6 6
4 78.48 45 13.95 480 301 2.37 / 759.92 6 6
5 0.00 170 14.16 357 859 3.23 / 760.78 6 15
Average= 5.25 (KJ/cycle)

Cycle 143 GMT 9/10/2017 15:11: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.72 31 14.10 482 211 0.21 / 750.84 6 6
2 1114.36 4 10.37 1999 83 0.29 / 750.92 6 6
3 1902.68 100 8.56 3043 2605 2.90 / 753.53 6 6
4 1889.08 91 9.90 3061 2758 5.66 / 756.29 6 6
5 126.88 45 13.79 593 368 6.02 / 756.65 6 6
6 0.04 170 14.15 372 895 6.92 / 757.55 6 12
Average= 5.26 (KJ/cycle)

Cycle 142 GMT 8/10/2017 12:30: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.52 30 14.04 500 211 0.21 / 746.20 6 6
2 970.80 -1 14.04 500 0. 0.00 / 746.20 6 6
3 1165.00 101 5.90 1881 1121 1.33 / 747.32 6 6
4 1173.12 91 8.90 2027 1642 2.97 / 748.96 6 6
5 314.00 45 13.36 873 525 3.50 / 749.49 6 6
6 41.68 45 13.99 426 268 3.77 / 749.76 6 6
7 -0.04 170 14.14 364 875 4.64 / 750.63 6 18
Average= 5.25 (KJ/cycle)

Cycle 141 GMT 28/ 9/2017 17:42: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.92 31 14.17 500 220 0.22 / 742.98 6 6
2 1012.48 91 6.84 1739 1082 1.30 / 744.06 6 6
3 631.20 45 12.72 1342 768 2.07 / 744.83 6 6
4 80.40 45 13.95 479 301 2.37 / 745.13 6 6
5 0.04 170 14.18 357 861 3.23 / 745.99 6 15
Average= 5.25 (KJ/cycle)

Cycle 140 GMT 18/ 9/2017 23:35: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.08 31 14.10 500 219 0.22 / 736.09 6 6
2 1131.24 4 10.53 1973 83 0.30 / 736.18 6 6
3 1907.32 100 8.61 3038 2616 2.92 / 738.79 6 6
4 1894.32 91 9.90 3034 2733 5.65 / 741.53 6 6
5 134.88 45 13.81 587 365 6.02 / 741.89 6 6
6 0.08 170 14.21 359 867 6.88 / 742.76 6 12
Average= 5.27 (KJ/cycle)

Cycle 139 GMT 17/ 9/2017 21:16: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.12 31 14.10 482 211 0.21 / 731.53 6 6
2 953.76 -1 14.10 482 0. 0.00 / 731.53 6 6
3 1155.52 101 6.11 1903 1174 1.39 / 732.71 6 6
4 1162.76 91 9.15 2013 1676 3.06 / 734.38 6 6
5 164.84 45 13.65 650 399 3.46 / 734.78 6 6
6 6.72 45 14.13 361 230 3.69 / 735.01 6 6
7 0.04 170 14.18 358 863 4.55 / 735.88 6 26
Average= 5.26 (KJ/cycle)

Cycle 138 GMT 8/ 9/2017 2:19: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.68 31 14.10 500 219 0.22 / 728.29 6 6
2 1006.20 91 6.86 1738 1085 1.30 / 729.38 6 6
3 628.00 45 12.74 1336 766 2.07 / 730.15 6 6
4 87.52 45 13.92 499 313 2.38 / 730.46 6 6
5 0.08 170 14.17 359 865 3.25 / 731.32 6 17
Average= 5.26 (KJ/cycle)

Cycle 137 GMT 29/ 8/2017 8: 8: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.32 31 14.17 500 220 0.22 / 721.39 6 6
2 1139.24 4 10.73 1973 85 0.30 / 721.48 6 6
3 1902.00 100 8.71 3058 2664 2.97 / 724.14 6 6
4 1886.76 90 9.95 3025 2709 5.68 / 726.85 6 6
5 145.24 45 13.80 597 371 6.05 / 727.22 6 6
6 0.08 170 14.23 354 856 6.90 / 728.08 6 13
Average= 5.28 (KJ/cycle)

Cycle 136 GMT 28/ 8/2017 5:48: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.08 30 14.10 482 204 0.20 / 716.92 6 6
2 1021.36 1 10.41 1892 20 0.22 / 716.94 6 6
3 1166.16 101 6.41 1925 1246 1.47 / 718.19 6 6
4 1171.88 91 9.42 2040 1749 3.22 / 719.93 6 6
5 146.64 45 13.72 612 378 3.60 / 720.31 6 6
6 0.04 170 14.17 357 860 4.46 / 721.17 6 11
Average= 5.26 (KJ/cycle)

Cycle 135 GMT 18/ 8/2017 11: 1: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.72 31 14.10 500 219 0.22 / 713.73 6 6
2 1014.88 91 7.04 1767 1132 1.35 / 714.86 6 6
3 494.96 45 12.99 1138 665 2.02 / 715.53 6 6
4 89.40 45 13.86 514 321 2.34 / 715.85 6 6
5 0.00 170 14.13 360 865 3.20 / 716.72 6 18
Average= 5.27 (KJ/cycle)

Cycle 134 GMT 8/ 8/2017 16:56: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.16 29 14.04 500 204 0.20 / 706.73 6 6
2 1073.76 2 11.24 1982 45 0.25 / 706.78 6 6
3 1034.04 1 10.98 1910 21 0.27 / 706.80 6 6
4 1173.52 4 10.89 2017 88 0.36 / 706.89 6 6
5 1901.68 100 8.86 3040 2693 3.05 / 709.58 6 6
6 1885.32 91 9.89 3023 2721 5.77 / 712.30 6 6
7 108.00 45 13.81 559 347 6.12 / 712.65 6 6
8 0.08 170 14.15 360 866 6.98 / 713.51 6 13
Average= 5.29 (KJ/cycle)

Cycle 133 GMT 7/ 8/2017 14: 0: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.76 30 14.04 500 211 0.21 / 703.49 6 6
2 1019.04 1 10.41 1821 19 0.23 / 703.51 6 6
3 1022.52 91 6.99 1768 1125 1.35 / 704.64 6 6
4 511.00 45 12.88 1168 677 2.03 / 705.31 6 6
5 83.60 45 13.82 518 322 2.35 / 705.64 6 6
6 0.00 170 14.06 374 894 3.25 / 706.53 6 19
Average= 5.27 (KJ/cycle)

Cycle 132 GMT 28/ 7/2017 19:59: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.16 31 14.10 482 211 0.21 / 700.30 6 6
2 1004.76 91 7.19 1737 1137 1.35 / 701.44 6 6
3 468.04 45 13.05 1092 641 1.99 / 702.08 6 6
4 68.04 45 13.87 488 305 2.29 / 702.38 6 6
5 -0.20 171 14.06 374 899 3.19 / 703.28 6 22
Average= 5.29 (KJ/cycle)

Cycle 131 GMT 19/ 7/2017 1:56: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.84 29 14.04 500 204 0.20 / 693.12 6 6
2 1071.56 2 11.56 1892 44 0.25 / 693.16 6 6
3 1037.28 1 10.92 1928 21 0.27 / 693.18 6 6
4 1162.56 4 11.27 2098 95 0.36 / 693.27 6 6
5 1902.80 100 9.11 3071 2798 3.16 / 696.07 6 6
6 1887.24 91 10.03 3056 2789 5.95 / 698.86 6 6
7 97.88 45 13.82 535 333 6.28 / 699.19 6 6
8 0.04 170 14.13 373 896 7.18 / 700.09 6 18
Average= 5.30 (KJ/cycle)

Cycle 130 GMT 18/ 7/2017 5:44: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.28 31 14.17 482 212 0.21 / 689.92 6 6
2 957.12 -1 14.17 482 0. 0.00 / 689.92 6 6
3 1013.16 91 7.01 1747 1114 1.33 / 691.04 6 6
4 508.40 45 12.93 1156 673 2.00 / 691.71 6 6
5 88.92 45 13.82 524 326 2.32 / 692.03 6 6
6 -0.04 170 14.10 366 877 3.20 / 692.91 6 18
Average= 5.29 (KJ/cycle)

Cycle 129 GMT 8/ 7/2017 11:41: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.88 31 14.10 500 219 0.22 / 686.66 6 6
2 997.92 90 6.94 1728 1079 1.30 / 687.73 6 6
3 733.76 45 12.56 1466 829 2.13 / 688.56 6 6
4 61.48 45 13.92 460 288 2.41 / 688.85 6 6
5 0.08 170 14.15 357 859 3.27 / 689.71 6 18
Average= 5.31 (KJ/cycle)

Cycle 128 GMT 28/ 6/2017 17:57: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.52 30 14.10 482 204 0.20 / 681.24 6 6
2 956.40 -1 14.10 482 0. 0.00 / 681.24 6 6
3 1134.36 60 10.75 2029 1309 1.51 / 682.55 6 6
4 686.28 100 11.62 1384 1608 3.12 / 684.16 6 6
5 666.76 90 11.39 1342 1376 4.50 / 685.54 6 6
6 -0.20 170 14.04 377 900 5.40 / 686.44 6 33
Average= 5.32 (KJ/cycle)

Cycle 127 GMT 28/ 6/2017 0:11: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.12 31 14.10 482 211 0.21 / 678.02 6 6
2 992.96 91 7.20 1732 1135 1.35 / 679.15 6 6
3 586.52 45 12.75 1275 732 2.08 / 679.89 6 6
4 64.12 45 13.93 462 290 2.37 / 680.18 6 6
5 0.00 170 14.12 360 864 3.23 / 681.04 6 18
Average= 5.32 (KJ/cycle)

Cycle 126 GMT 18/ 6/2017 6:18: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.88 31 14.10 500 219 0.22 / 674.79 6 6
2 1008.16 91 6.99 1745 1110 1.33 / 675.90 6 6
3 626.04 45 12.79 1307 752 2.08 / 676.65 6 6
4 77.92 45 13.93 475 298 2.38 / 676.95 6 6
5 0.16 170 14.17 357 860 3.24 / 677.81 6 20
Average= 5.34 (KJ/cycle)

Cycle 125 GMT 8/ 6/2017 12:27: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.96 31 14.10 500 219 0.22 / 669.46 6 6
2 959.92 -1 14.10 500 0. 0.00 / 669.46 6 6
3 1161.28 60 10.78 2050 1326 1.54 / 670.79 6 6
4 642.56 100 11.78 1324 1560 3.10 / 672.35 6 6
5 618.92 91 11.51 1266 1326 4.43 / 673.67 6 6
6 0.24 170 14.04 376 897 5.33 / 674.57 6 37
Average= 5.35 (KJ/cycle)

Cycle 124 GMT 7/ 6/2017 18:43: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.84 30 14.10 500 211 0.21 / 666.19 6 6
2 1031.20 1 11.05 1857 21 0.23 / 666.21 6 6
3 1017.00 91 7.12 1784 1156 1.39 / 667.37 6 6
4 497.60 45 12.94 1155 673 2.06 / 668.04 6 6
5 85.20 45 13.85 514 320 2.38 / 668.36 6 6
6 0.00 170 14.10 369 884 3.27 / 669.24 6 18
Average= 5.35 (KJ/cycle)

Cycle 123 GMT 29/ 5/2017 0:42: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.00 30 14.04 482 203 0.20 / 663.00 6 6
2 1024.24 91 6.96 1764 1117 1.32 / 664.11 6 6
3 503.64 45 13.01 1141 668 1.99 / 664.78 6 6
4 97.12 45 13.85 523 326 2.31 / 665.11 6 6
5 0.08 170 14.15 362 871 3.19 / 665.98 6 20
Average= 5.37 (KJ/cycle)

Cycle 122 GMT 19/ 5/2017 6:45: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.52 30 14.10 482 204 0.20 / 657.72 6 6
2 1031.68 1 11.24 1839 21 0.22 / 657.74 6 6
3 1152.76 60 10.76 2052 1325 1.55 / 659.06 6 6
4 624.56 100 11.77 1300 1530 3.08 / 660.59 6 6
5 599.92 91 11.52 1243 1303 4.38 / 661.89 6 6
6 -0.08 170 14.05 376 898 5.28 / 662.79 6 39
Average= 5.39 (KJ/cycle)

Cycle 121 GMT 18/ 5/2017 13: 0: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.80 31 14.10 482 211 0.21 / 654.54 6 6
2 964.88 -1 14.10 482 0. 0.00 / 654.54 6 6
3 1018.52 91 7.09 1741 1123 1.33 / 655.66 6 6
4 506.20 45 12.90 1150 668 2.00 / 656.33 6 6
5 90.96 45 13.83 513 319 2.32 / 656.65 6 6
6 0.04 170 14.11 359 861 3.18 / 657.51 6 19
Average= 5.39 (KJ/cycle)

Cycle 120 GMT 8/ 5/2017 18:55: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.40 33 14.10 500 233 0.23 / 651.29 6 6
2 922.60 -1 14.10 500 0. 0.00 / 651.29 6 6
3 966.76 -1 14.10 500 0. 0.00 / 651.29 6 6
4 1026.48 91 6.86 1752 1094 1.33 / 652.39 6 6
5 633.04 45 12.70 1348 770 2.10 / 653.16 6 6
6 87.00 45 13.92 494 309 2.41 / 653.47 6 6
7 0.12 170 14.18 359 865 3.27 / 654.33 6 15
Average= 5.41 (KJ/cycle)

Cycle 119 GMT 29/ 4/2017 1: 0: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.52 34 14.10 500 240 0.24 / 645.97 6 6
2 885.96 -2 14.10 500 0. 0.00 / 645.97 6 6
3 968.24 -1 14.10 500 0. 0.00 / 645.97 6 6
4 1144.12 60 10.72 2029 1305 1.54 / 647.27 6 6
5 648.04 100 11.69 1334 1559 3.10 / 648.83 6 6
6 624.72 91 11.48 1275 1332 4.44 / 650.16 6 6
7 -0.12 170 14.07 374 895 5.33 / 651.06 6 31
Average= 5.43 (KJ/cycle)

Cycle 118 GMT 28/ 4/2017 7:12: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.48 31 14.17 482 212 0.21 / 642.77 6 6
2 1011.88 91 6.55 1728 1030 1.24 / 643.80 6 6
3 630.12 45 12.52 1341 756 2.00 / 644.56 6 6
4 91.36 45 13.90 499 312 2.31 / 644.87 6 6
5 -0.04 170 14.19 356 859 3.17 / 645.73 6 15
Average= 5.43 (KJ/cycle)

Cycle 117 GMT 18/ 4/2017 13: 9: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.24 23 14.10 482 156 0.16 / 639.30 6 6
2 1012.80 5 12.44 1892 118 0.27 / 639.42 6 6
3 1044.20 3 12.89 1964 76 0.35 / 639.49 6 6
4 1051.64 1 11.75 1892 22 0.37 / 639.51 6 6
5 1019.88 91 6.98 1756 1115 1.49 / 640.63 6 6
6 625.72 45 12.78 1322 760 2.25 / 641.39 6 6
7 82.08 45 13.97 488 307 2.55 / 641.70 6 6
8 0.16 170 14.22 357 863 3.42 / 642.56 6 14
Average= 5.45 (KJ/cycle)

Cycle 116 GMT 8/ 4/2017 19:20: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 117.00 21 14.23 500 149 0.15 / 633.75 6 6
2 1055.52 5 12.25 1946 119 0.27 / 633.87 6 6
3 1096.76 4 12.51 2035 102 0.37 / 633.97 6 6
4 1116.24 3 11.69 2017 71 0.44 / 634.04 6 6
5 1057.24 1 10.98 1910 21 0.46 / 634.06 6 6
6 1193.16 60 10.97 2109 1388 1.85 / 635.45 6 6
7 601.76 100 12.02 1270 1527 3.38 / 636.98 6 6
8 581.12 91 11.69 1216 1294 4.67 / 638.27 6 6
9 -0.16 170 14.16 363 874 5.54 / 639.14 6 35
Average= 5.46 (KJ/cycle)

Cycle 115 GMT 8/ 4/2017 1:22: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.52 31 14.23 482 213 0.21 / 625.70 6 6
2 2008.32 69 10.84 417 312 0.52 / 626.02 6 6
3 2011.60 101 4.68 2040 964 1.49 / 626.98 6 6
4 2017.64 91 5.50 2979 1491 2.98 / 628.47 6 6
5 1966.40 45 10.36 3166 1476 4.46 / 629.95 6 6
6 1796.12 45 11.16 2959 1486 5.94 / 631.43 6 6
7 898.64 45 12.55 1679 948 6.89 / 632.38 6 6
8 123.80 45 13.96 551 346 7.24 / 632.73 6 6
9 -0.04 170 14.30 358 870 8.11 / 633.60 6 10
Average= 5.46 (KJ/cycle)

Cycle 114 GMT 29/ 3/2017 0:47: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.00 31 14.23 500 221 0.22 / 617.60 6 6
2 2006.56 69 10.77 420 312 0.53 / 617.91 6 6
3 2009.12 101 4.68 2039 964 1.50 / 618.88 6 6
4 2013.76 91 5.52 2957 1485 2.98 / 620.36 6 6
5 1953.60 45 10.36 3176 1481 4.46 / 621.84 6 6
6 1774.56 45 11.28 2898 1471 5.93 / 623.31 6 6
7 849.12 45 12.65 1628 927 6.86 / 624.24 6 6
8 149.00 45 13.83 619 385 7.25 / 624.63 6 6
9 0.12 170 14.27 357 866 8.11 / 625.49 6 20
Average= 5.44 (KJ/cycle)

Cycle 113 GMT 19/ 3/2017 0:35: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.00 31 14.17 482 212 0.21 / 609.66 6 6
2 2008.20 69 10.45 410 296 0.51 / 609.95 6 6
3 2011.36 101 4.66 1902 895 1.40 / 610.85 6 6
4 2017.24 91 5.40 2904 1427 2.83 / 612.28 6 6
5 1991.56 44 10.46 3221 1482 4.31 / 613.76 6 6
6 1820.36 45 11.29 2975 1511 5.82 / 615.27 6 6
7 891.28 45 12.63 1663 945 6.77 / 616.22 6 6
8 115.72 45 13.95 536 336 7.11 / 616.55 6 6
9 0.08 170 14.32 340 828 7.93 / 617.38 6 14
Average= 5.42 (KJ/cycle)

Cycle 112 GMT 9/ 3/2017 0:13: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.64 31 14.23 482 213 0.21 / 601.81 6 6
2 1142.64 35 4.66 1781 290 0.50 / 602.10 6 6
3 2007.72 111 4.93 2697 1476 1.98 / 603.58 6 6
4 2013.16 91 7.61 3274 2267 4.25 / 605.85 6 6
5 1832.80 45 11.32 2993 1525 5.77 / 607.37 6 6
6 741.08 45 12.82 1477 852 6.62 / 608.22 6 6
7 126.80 45 13.91 577 361 6.98 / 608.59 6 6
8 0.00 170 14.28 355 862 7.85 / 609.45 6 15
Average= 5.39 (KJ/cycle)

Cycle 111 GMT 27/ 2/2017 0: 6: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.40 31 14.23 500 221 0.22 / 594.73 6 6
2 1158.60 17 4.67 1650 131 0.35 / 594.87 6 6
3 2010.04 80 4.76 2258 860 1.21 / 595.73 6 6
4 2015.68 71 6.06 3057 1315 2.53 / 597.04 6 6
5 1928.96 38 11.08 3144 1324 3.85 / 598.36 6 6
6 1750.00 38 11.66 2860 1267 5.12 / 599.63 6 6
7 843.12 38 12.82 1604 781 5.90 / 600.41 6 6
8 169.44 38 13.83 643 338 6.24 / 600.75 6 6
9 -0.04 170 14.30 350 851 7.09 / 601.60 6 8
Average= 5.37 (KJ/cycle)

Cycle 110 GMT 16/ 2/2017 23:33: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.24 31 14.23 482 213 0.21 / 587.66 6 6
2 1141.28 17 4.66 1586 126 0.34 / 587.78 6 6
3 2002.20 80 4.75 2222 844 1.18 / 588.63 6 6
4 2008.80 71 6.09 3064 1325 2.51 / 589.95 6 6
5 1935.52 38 11.13 3150 1332 3.84 / 591.28 6 6
6 1751.96 38 11.66 2895 1283 5.12 / 592.57 6 6
7 880.56 38 12.83 1624 792 5.91 / 593.36 6 6
8 117.20 38 13.98 550 292 6.21 / 593.65 6 6
9 0.08 170 14.31 355 864 7.07 / 594.51 6 8
Average= 5.36 (KJ/cycle)

Cycle 109 GMT 6/ 2/2017 22:55: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.96 31 14.29 500 221 0.22 / 580.53 6 6
2 1153.60 26 4.69 1780 217 0.44 / 580.74 6 6
3 2004.12 50 4.91 2834 696 1.13 / 581.44 6 6
4 2008.84 71 6.71 3287 1566 2.70 / 583.01 6 6
5 1893.64 38 11.42 3094 1343 4.04 / 584.35 6 6
6 1503.92 38 12.00 2524 1151 5.19 / 585.50 6 6
7 801.40 38 12.95 1540 758 5.95 / 586.26 6 6
8 130.64 38 13.92 590 312 6.26 / 586.57 6 6
9 -0.08 170 14.29 360 875 7.14 / 587.44 6 16
Average= 5.34 (KJ/cycle)

Cycle 108 GMT 27/ 1/2017 22:31: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.72 31 14.29 482 214 0.21 / 573.82 6 6
2 1151.76 25 5.31 1815 241 0.45 / 574.06 6 6
3 1985.76 50 4.95 2969 735 1.19 / 574.79 6 6
4 1985.56 71 7.76 3211 1769 2.96 / 576.56 6 6
5 1802.08 38 11.42 2938 1275 4.23 / 577.84 6 6
6 1147.12 38 12.44 2016 953 5.19 / 578.79 6 6
7 226.52 38 13.70 747 389 5.58 / 579.18 6 6
8 47.00 38 14.16 436 235 5.81 / 579.41 6 6
9 0.00 170 14.28 367 891 6.70 / 580.31 6 18
Average= 5.32 (KJ/cycle)

Cycle 107 GMT 17/ 1/2017 21: 9: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.08 31 14.29 482 214 0.21 / 567.15 6 6
2 1148.92 13 4.70 1731 106 0.32 / 567.25 6 6
3 2003.16 30 4.90 2667 392 0.71 / 567.65 6 6
4 2007.24 70 6.10 3340 1426 2.14 / 569.07 6 6
5 1951.64 37 11.24 3118 1297 3.43 / 570.37 6 6
6 1774.88 37 11.69 2890 1250 4.68 / 571.62 6 6
7 884.16 38 12.84 1684 822 5.51 / 572.44 6 6
8 139.64 38 13.99 587 312 5.82 / 572.75 6 6
9 0.04 170 14.36 349 852 6.67 / 573.60 6 8
Average= 5.31 (KJ/cycle)

Cycle 106 GMT 7/ 1/2017 20:23: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.36 31 14.29 500 221 0.22 / 560.57 6 6
2 1143.76 13 4.79 1716 107 0.33 / 560.68 6 6
3 2002.04 30 4.92 2715 401 0.73 / 561.08 6 6
4 2005.12 71 6.16 3417 1494 2.22 / 562.57 6 6
5 1924.32 38 11.29 3119 1338 3.56 / 563.91 6 6
6 1526.52 38 11.99 2558 1165 4.73 / 565.08 6 6
7 669.84 38 13.08 1387 689 5.42 / 565.77 6 6
8 118.76 38 13.99 563 299 5.72 / 566.07 6 6
9 0.00 170 14.31 357 868 6.58 / 566.93 6 10
Average= 5.30 (KJ/cycle)

Cycle 105 GMT 28/12/2016 19:26:58

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.92 31 14.29 482 214 0.21 / 554.19 6 6
2 1169.36 13 4.74 1773 109 0.32 / 554.30 6 6
3 2000.68 30 4.92 2856 422 0.74 / 554.72 6 6
4 2003.24 71 7.39 3195 1676 2.42 / 556.40 6 6
5 1851.16 38 11.32 3006 1293 3.71 / 557.69 6 6
6 1426.64 38 12.12 2398 1104 4.82 / 558.80 6 6
7 287.80 38 13.62 845 437 5.26 / 559.23 6 6
8 71.08 38 14.16 465 250 5.51 / 559.48 6 6
9 0.12 170 14.34 355 865 6.37 / 560.35 6 13
Average= 5.29 (KJ/cycle)

Cycle 104 GMT 18/12/2016 19: 0: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.08 31 14.29 500 221 0.22 / 548.00 6 6
2 1133.96 13 5.17 1740 117 0.34 / 548.12 6 6
3 2004.56 30 4.98 2941 439 0.78 / 548.56 6 6
4 2007.92 71 7.70 3184 1741 2.52 / 550.30 6 6
5 1841.00 38 11.33 3035 1307 3.83 / 551.60 6 6
6 1018.28 38 12.62 1859 892 4.72 / 552.49 6 6
7 185.04 38 13.78 688 360 5.08 / 552.85 6 6
8 47.28 38 14.20 428 231 5.31 / 553.09 6 6
9 0.00 170 14.28 368 893 6.20 / 553.98 6 19
Average= 5.28 (KJ/cycle)

Cycle 103 GMT 8/12/2016 18:17: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.04 31 14.29 500 221 0.22 / 541.72 6 6
2 1145.56 13 5.36 1779 124 0.35 / 541.85 6 6
3 2001.52 30 4.98 3056 457 0.80 / 542.30 6 6
4 2003.44 70 8.02 3190 1791 2.59 / 544.09 6 6
5 1800.88 38 11.39 2960 1281 3.87 / 545.38 6 6
6 1132.80 38 12.43 2030 959 4.83 / 546.33 6 6
7 184.56 37 13.81 682 348 5.18 / 546.68 6 6
8 44.20 37 14.21 418 220 5.40 / 546.90 6 6
9 -0.04 170 14.30 360 875 6.28 / 547.78 6 21
Average= 5.27 (KJ/cycle)

Cycle 102 GMT 28/11/2016 17:53: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.08 30 14.29 500 214 0.21 / 535.58 6 6
2 1170.64 13 5.78 1844 139 0.35 / 535.71 6 6
3 2002.88 30 5.04 3304 500 0.85 / 536.21 6 6
4 2005.88 71 8.72 3172 1964 2.82 / 538.18 6 6
5 1836.08 38 11.38 3031 1311 4.13 / 539.49 6 6
6 931.88 38 12.72 1744 843 4.97 / 540.33 6 6
7 131.60 38 13.97 587 312 5.28 / 540.64 6 6
8 0.00 170 14.31 353 859 6.14 / 541.50 6 11
Average= 5.26 (KJ/cycle)

Cycle 101 GMT 18/11/2016 17: 4: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.68 30 14.23 500 213 0.21 / 529.44 6 6
2 1149.52 6 4.85 1708 50 0.26 / 529.49 6 6
3 2004.56 25 4.96 2878 357 0.62 / 529.84 6 6
4 2008.20 71 8.27 3206 1882 2.50 / 531.73 6 6
5 1827.12 38 11.43 2998 1302 3.80 / 533.03 6 6
6 989.20 38 12.66 1832 881 4.69 / 533.91 6 6
7 157.96 38 13.89 639 337 5.02 / 534.25 6 6
8 42.52 38 14.22 428 231 5.25 / 534.48 6 6
9 0.00 170 14.31 363 883 6.14 / 535.36 6 20
Average= 5.25 (KJ/cycle)

Cycle 100 GMT 8/11/2016 16:39:59

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.28 30 14.29 482 207 0.21 / 523.10 6 6
2 1149.60 6 4.72 1791 51 0.26 / 523.15 6 6
3 2004.24 25 5.00 3056 382 0.64 / 523.53 6 6
4 2008.88 71 8.58 3189 1943 2.58 / 525.48 6 6
5 1835.44 38 11.42 2990 1298 3.88 / 526.77 6 6
6 1161.28 38 12.46 2029 961 4.84 / 527.73 6 6
7 205.72 38 13.82 702 369 5.21 / 528.10 6 6
8 41.68 38 14.20 432 233 5.44 / 528.34 6 6
9 0.04 170 14.27 366 888 6.33 / 529.22 6 25
Average= 5.24 (KJ/cycle)

Cycle 99 GMT 29/10/2016 16:42:58

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.12 30 14.29 482 207 0.21 / 516.98 6 6
2 1153.56 6 4.72 1785 51 0.26 / 517.03 6 6
3 2008.00 25 4.99 3049 380 0.64 / 517.41 6 6
4 2012.20 71 8.69 3149 1943 2.58 / 519.35 6 6
5 1829.84 38 11.44 2953 1284 3.86 / 520.64 6 6
6 944.92 38 12.71 1749 845 4.71 / 521.48 6 6
7 152.64 38 13.94 620 328 5.04 / 521.81 6 6
8 14.48 38 14.30 379 206 5.24 / 522.02 6 6
9 -0.04 170 14.29 361 877 6.12 / 522.89 6 20
Average= 5.23 (KJ/cycle)

Cycle 98 GMT 19/10/2016 16: 9: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.12 30 14.29 482 207 0.21 / 511.12 6 6
2 1159.20 6 5.24 1737 55 0.26 / 511.17 6 6
3 2002.36 25 5.44 3108 423 0.68 / 511.59 6 6
4 2005.04 71 8.94 3152 2001 2.68 / 513.59 6 6
5 1611.24 38 11.82 2647 1189 3.87 / 514.78 6 6
6 917.12 38 12.77 1702 826 4.70 / 515.61 6 6
7 105.08 38 14.03 536 286 4.99 / 515.90 6 6
8 0.08 170 14.27 362 878 5.86 / 516.77 6 12
Average= 5.22 (KJ/cycle)

Cycle 97 GMT 9/10/2016 16:15:59

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.08 30 14.29 482 207 0.21 / 505.16 6 6
2 1153.40 6 5.45 1779 58 0.26 / 505.22 6 6
3 2000.64 25 6.30 3031 477 0.74 / 505.70 6 6
4 2003.04 71 9.17 3149 2050 2.79 / 507.75 6 6
5 1803.92 38 11.53 2982 1307 4.10 / 509.05 6 6
6 683.36 38 13.09 1384 688 4.79 / 509.74 6 6
7 109.80 38 14.04 550 293 5.08 / 510.04 6 6
8 0.04 170 14.28 360 874 5.95 / 510.91 6 12
Average= 5.21 (KJ/cycle)

Cycle 96 GMT 29/ 9/2016 16: 3:59

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.04 30 14.29 464 199 0.20 / 499.36 6 6
2 1150.76 5 5.51 1815 50 0.25 / 499.41 6 6
3 2001.64 70 7.75 3137 1702 1.95 / 501.11 6 6
4 1823.64 38 11.52 2984 1306 3.26 / 502.41 6 6
5 1186.40 38 12.45 2055 972 4.23 / 503.39 6 6
6 273.00 38 13.70 823 428 4.66 / 503.81 6 6
7 56.88 37 14.17 462 242 4.90 / 504.06 6 6
8 -0.08 170 14.24 371 898 5.80 / 504.96 6 19
Average= 5.21 (KJ/cycle)

Cycle 95 GMT 19/ 9/2016 15:44: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.32 30 14.29 464 199 0.20 / 493.54 6 6
2 1139.72 5 6.28 1767 55 0.25 / 493.60 6 6
3 2003.24 70 7.89 3138 1733 1.99 / 495.33 6 6
4 1839.36 38 11.55 3004 1318 3.31 / 496.65 6 6
5 1183.36 38 12.42 2072 978 4.28 / 497.63 6 6
6 252.24 37 13.72 794 403 4.69 / 498.03 6 6
7 57.04 37 14.16 459 240 4.93 / 498.27 6 6
8 0.00 170 14.24 366 886 5.81 / 499.16 6 17
Average= 5.20 (KJ/cycle)

Cycle 94 GMT 9/ 9/2016 15: 4: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.08 30 14.29 482 207 0.21 / 487.82 6 6
2 1160.52 5 6.54 1874 61 0.27 / 487.88 6 6
3 2001.40 70 8.35 3206 1874 2.14 / 489.76 6 6
4 1823.64 38 11.58 2969 1306 3.45 / 491.06 6 6
5 962.92 38 12.70 1747 843 4.29 / 491.91 6 6
6 150.96 38 13.92 630 333 4.62 / 492.24 6 6
7 39.88 37 14.22 426 224 4.85 / 492.46 6 6
8 0.04 170 14.26 363 880 5.73 / 493.34 6 19
Average= 5.19 (KJ/cycle)

Cycle 93 GMT 30/ 8/2016 14:51: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.28 30 14.29 464 199 0.20 / 481.96 6 6
2 1151.36 5 6.79 1844 63 0.26 / 482.03 6 6
3 2005.40 70 8.45 3202 1894 2.16 / 483.92 6 6
4 1822.44 38 11.50 2978 1301 3.46 / 485.22 6 6
5 1153.72 38 12.44 2034 962 4.42 / 486.18 6 6
6 177.24 38 13.84 674 354 4.77 / 486.54 6 6
7 17.56 37 14.25 392 207 4.98 / 486.74 6 6
8 0.04 170 14.27 359 871 5.85 / 487.61 6 20
Average= 5.19 (KJ/cycle)

Cycle 92 GMT 20/ 8/2016 14:37: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.60 30 14.29 482 207 0.21 / 476.31 6 6
2 1151.80 5 7.05 1886 66 0.27 / 476.37 6 6
3 2001.60 70 8.64 3162 1912 2.19 / 478.29 6 6
4 1799.40 38 11.51 2934 1283 3.47 / 479.57 6 6
5 893.96 38 12.79 1672 813 4.28 / 480.38 6 6
6 120.56 38 14.03 560 299 4.58 / 480.68 6 6
7 27.92 37 14.27 404 213 4.79 / 480.89 6 6
8 0.04 170 14.29 358 870 5.66 / 481.76 6 17
Average= 5.18 (KJ/cycle)

Cycle 91 GMT 10/ 8/2016 13:28: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.20 30 14.29 464 199 0.20 / 471.02 6 6
2 1155.16 5 7.38 1898 70 0.27 / 471.09 6 6
3 1989.44 70 8.80 3174 1955 2.22 / 473.04 6 6
4 1606.44 38 11.81 2645 1187 3.41 / 474.23 6 6
5 729.80 38 13.01 1437 710 4.12 / 474.94 6 6
6 116.48 38 14.00 565 301 4.42 / 475.24 6 6
7 0.04 170 14.24 356 862 5.28 / 476.10 6 11
Average= 5.18 (KJ/cycle)

Cycle 90 GMT 31/ 7/2016 12: 6: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.36 30 14.29 464 199 0.20 / 465.65 6 6
2 1138.12 5 7.79 1910 74 0.27 / 465.72 6 6
3 1977.68 70 9.03 3142 1986 2.26 / 467.71 6 6
4 1565.72 38 11.84 2608 1173 3.43 / 468.88 6 6
5 864.88 38 12.83 1619 789 4.22 / 469.67 6 6
6 98.52 38 14.06 525 280 4.50 / 469.95 6 6
7 -0.08 170 14.24 358 867 5.37 / 470.82 6 13
Average= 5.17 (KJ/cycle)

Cycle 89 GMT 21/ 7/2016 10:48: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.88 30 14.29 482 207 0.21 / 460.43 6 6
2 1154.40 3 7.18 1973 42 0.25 / 460.47 6 6
3 2006.24 70 9.14 3177 2033 2.28 / 462.51 6 6
4 1615.72 37 11.81 2665 1165 3.45 / 463.67 6 6
5 743.44 37 13.03 1424 687 4.13 / 464.36 6 6
6 136.64 37 13.99 560 290 4.42 / 464.65 6 6
7 0.64 170 14.28 330 801 5.22 / 465.45 6 12
Average= 5.17 (KJ/cycle)

Cycle 88 GMT 11/ 7/2016 10:31: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.84 30 14.23 464 198 0.20 / 454.77 6 6
2 1143.64 3 7.15 1892 41 0.24 / 454.81 6 6
3 2003.16 70 9.08 3163 2010 2.25 / 456.82 6 6
4 1809.24 37 11.48 2923 1242 3.49 / 458.06 6 6
5 884.68 37 12.79 1654 783 4.27 / 458.85 6 6
6 115.48 37 14.01 554 287 4.56 / 459.13 6 6
7 59.04 36 14.19 451 230 4.79 / 459.36 6 6
8 0.00 170 14.24 356 862 5.65 / 460.22 6 20
Average= 5.17 (KJ/cycle)

Cycle 87 GMT 1/ 7/2016 10: 4: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.56 30 14.29 482 207 0.21 / 449.77 6 6
2 1157.28 2 6.87 2017 28 0.23 / 449.80 6 6
3 1675.80 70 9.56 2765 1850 2.08 / 451.65 6 6
4 1493.00 35 11.96 2507 1049 3.13 / 452.69 6 6
5 606.32 35 13.20 1276 590 3.72 / 453.28 6 6
6 90.88 35 14.05 521 256 3.98 / 453.54 6 6
7 7.04 35 14.30 359 180 4.16 / 453.72 6 6
8 0.00 170 14.23 352 852 5.01 / 454.57 6 21
Average= 5.17 (KJ/cycle)

Cycle 86 GMT 21/ 6/2016 9:21: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.72 30 14.29 482 207 0.21 / 444.25 6 6
2 1141.92 2 6.99 1999 28 0.23 / 444.28 6 6
3 2000.44 70 9.46 3175 2102 2.34 / 446.38 6 6
4 1613.84 35 11.86 2682 1113 3.45 / 447.49 6 6
5 758.24 35 13.00 1493 679 4.13 / 448.17 6 6
6 135.88 35 13.94 603 294 4.42 / 448.46 6 6
7 30.56 36 14.23 419 215 4.64 / 448.68 6 6
8 0.00 170 14.21 365 882 5.52 / 449.56 6 15
Average= 5.17 (KJ/cycle)

Cycle 85 GMT 11/ 6/2016 8:56: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.16 30 14.23 500 213 0.21 / 438.78 6 6
2 1150.36 2 7.12 1981 28 0.24 / 438.80 6 6
3 2001.12 59 9.44 3203 1784 2.03 / 440.59 6 6
4 1807.72 37 11.52 2950 1257 3.28 / 441.85 6 6
5 928.96 37 12.75 1722 812 4.10 / 442.66 6 6
6 132.12 37 13.97 587 303 4.40 / 442.96 6 6
7 34.44 36 14.23 416 213 4.61 / 443.18 6 6
8 -0.04 170 14.22 358 865 5.48 / 444.04 6 20
Average= 5.16 (KJ/cycle)

Cycle 84 GMT 1/ 6/2016 8:46: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.84 30 14.23 482 206 0.21 / 433.22 6 6
2 1157.56 2 7.12 2053 29 0.24 / 433.25 6 6
3 2002.20 59 9.53 3206 1803 2.04 / 435.05 6 6
4 1802.20 37 11.61 2943 1264 3.30 / 436.32 6 6
5 935.48 37 12.74 1715 808 4.11 / 437.12 6 6
6 134.84 37 13.92 607 313 4.42 / 437.44 6 6
7 68.04 36 14.12 480 244 4.67 / 437.68 6 6
8 0.56 170 14.18 366 882 5.55 / 438.56 6 17
Average= 5.16 (KJ/cycle)

Cycle 83 GMT 22/ 5/2016 8:24: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.24 30 14.29 464 199 0.20 / 427.76 6 6
2 1152.28 2 7.92 1946 31 0.23 / 427.79 6 6
3 2002.96 59 9.68 3151 1800 2.03 / 429.59 6 6
4 1809.08 37 11.56 2924 1251 3.28 / 430.84 6 6
5 928.28 37 12.82 1666 790 4.07 / 431.63 6 6
6 125.36 37 13.97 581 300 4.37 / 431.93 6 6
7 32.36 36 14.23 411 211 4.58 / 432.14 6 6
8 -0.04 170 14.21 360 870 5.45 / 433.01 6 20
Average= 5.15 (KJ/cycle)

Cycle 82 GMT 12/ 5/2016 7:50: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.20 30 14.29 482 207 0.21 / 422.35 6 6
2 1163.20 2 7.92 2026 32 0.24 / 422.38 6 6
3 2005.68 59 9.77 3132 1805 2.04 / 424.18 6 6
4 1815.00 37 11.62 2935 1262 3.31 / 425.44 6 6
5 914.36 37 12.81 1649 782 4.09 / 426.23 6 6
6 121.88 36 14.01 550 277 4.36 / 426.50 6 6
7 63.00 36 14.20 440 225 4.59 / 426.73 6 6
8 -0.08 170 14.23 345 835 5.42 / 427.56 6 13
Average= 5.15 (KJ/cycle)

Cycle 81 GMT 2/ 5/2016 7:24: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.16 30 14.23 482 206 0.21 / 416.70 6 6
2 1175.76 2 7.50 2071 31 0.24 / 416.73 6 6
3 2002.52 59 9.74 3205 1842 2.08 / 418.58 6 6
4 1823.76 37 11.57 2938 1258 3.34 / 419.83 6 6
5 1132.12 37 12.52 1980 917 4.25 / 420.75 6 6
6 115.44 37 14.01 547 284 4.54 / 421.03 6 6
7 61.12 36 14.16 467 238 4.78 / 421.27 6 6
8 -0.04 170 14.20 359 867 5.64 / 422.14 6 18
Average= 5.15 (KJ/cycle)

Cycle 80 GMT 22/ 4/2016 7: 0: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.64 30 14.36 464 200 0.20 / 411.39 6 6
2 1149.40 2 7.72 1955 30 0.23 / 411.42 6 6
3 2002.24 59 9.82 3186 1846 2.08 / 413.27 6 6
4 1801.76 37 11.53 2979 1271 3.35 / 414.54 6 6
5 909.80 37 12.77 1691 799 4.15 / 415.34 6 6
6 124.44 37 13.98 578 299 4.44 / 415.64 6 6
7 0.04 170 14.23 356 861 5.31 / 416.50 6 12
Average= 5.14 (KJ/cycle)

Cycle 79 GMT 12/ 4/2016 6:16: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.68 30 14.29 464 199 0.20 / 406.13 6 6
2 1147.32 2 8.14 1919 31 0.23 / 406.16 6 6
3 2003.44 59 9.88 3166 1846 2.08 / 408.01 6 6
4 1626.56 37 11.81 2688 1175 3.25 / 409.18 6 6
5 757.76 37 12.99 1478 710 3.96 / 409.89 6 6
6 130.72 37 13.96 587 303 4.26 / 410.20 6 6
7 2.84 36 14.34 354 183 4.45 / 410.38 6 6
8 -0.04 170 14.23 335 810 5.26 / 411.19 6 13
Average= 5.14 (KJ/cycle)

Cycle 78 GMT 2/ 4/2016 4:59: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.64 30 14.36 464 200 0.20 / 401.24 6 6
2 1113.68 2 7.95 1892 30 0.23 / 401.27 6 6
3 1967.80 59 9.89 3188 1860 2.09 / 403.13 6 6
4 1411.36 35 12.13 2400 1019 3.11 / 404.15 6 6
5 765.24 35 13.08 1451 664 3.77 / 404.82 6 6
6 130.08 35 13.99 562 275 4.05 / 405.09 6 6
7 0.04 170 14.21 348 841 4.89 / 405.93 6 9
Average= 5.14 (KJ/cycle)

Cycle 77 GMT 23/ 3/2016 3:39: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.56 30 14.29 482 207 0.21 / 395.92 6 6
2 1128.88 2 7.76 1919 30 0.24 / 395.95 6 6
3 1983.32 59 9.98 3151 1855 2.09 / 397.81 6 6
4 1594.28 35 11.96 2627 1100 3.19 / 398.91 6 6
5 931.52 35 12.80 1740 780 3.97 / 399.69 6 6
6 104.68 35 14.04 542 266 4.24 / 399.95 6 6
7 24.88 36 14.27 406 209 4.45 / 400.16 6 6
8 -0.04 170 14.19 366 883 5.33 / 401.04 6 18
Average= 5.14 (KJ/cycle)

Cycle 76 GMT 13/ 3/2016 2:29: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.16 30 14.23 482 206 0.21 / 390.73 6 6
2 1120.56 2 7.22 2071 30 0.24 / 390.76 6 6
3 1937.48 59 10.08 3136 1865 2.10 / 392.63 6 6
4 1555.92 35 12.01 2592 1090 3.19 / 393.72 6 6
5 689.80 35 13.12 1394 640 3.83 / 394.36 6 6
6 104.60 35 14.02 549 269 4.10 / 394.63 6 6
7 24.60 36 14.23 406 208 4.31 / 394.83 6 6
8 -0.08 170 14.18 366 882 5.19 / 395.72 6 18
Average= 5.14 (KJ/cycle)

Cycle 75 GMT 3/ 3/2016 1:15: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.08 30 14.29 482 207 0.21 / 385.82 6 6
2 1132.28 2 7.22 2053 30 0.24 / 385.85 6 6
3 1947.00 59 10.24 3072 1856 2.09 / 387.71 6 6
4 1532.44 35 12.04 2556 1077 3.17 / 388.78 6 6
5 643.20 35 13.23 1324 613 3.78 / 389.40 6 6
6 96.92 35 14.04 535 263 4.05 / 389.66 6 6
7 0.04 170 14.20 359 867 4.91 / 390.53 6 10
Average= 5.14 (KJ/cycle)

Cycle 74 GMT 22/ 2/2016 0:13: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.40 30 14.29 482 207 0.21 / 380.70 6 6
2 1109.80 2 6.90 1990 27 0.23 / 380.73 6 6
3 1949.32 59 10.25 3121 1887 2.12 / 382.62 6 6
4 1536.64 34 12.04 2601 1065 3.19 / 383.68 6 6
5 678.56 34 13.14 1387 620 3.81 / 384.30 6 6
6 100.00 34 14.05 528 252 4.06 / 384.55 6 6
7 22.44 35 14.26 393 196 4.25 / 384.75 6 6
8 -0.12 170 14.18 358 863 5.12 / 385.61 6 18
Average= 5.14 (KJ/cycle)

Cycle 73 GMT 11/ 2/2016 23: 7: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.96 30 14.29 482 207 0.21 / 375.52 6 6
2 1112.48 2 6.83 1973 27 0.23 / 375.55 6 6
3 1948.76 59 10.25 3144 1901 2.13 / 377.45 6 6
4 1551.96 34 12.06 2611 1071 3.21 / 378.52 6 6
5 675.56 35 13.15 1380 635 3.84 / 379.16 6 6
6 101.80 35 14.01 546 268 4.11 / 379.42 6 6
7 12.12 35 14.26 389 194 4.30 / 379.62 6 6
8 -0.12 170 14.13 366 879 5.18 / 380.50 6 19
Average= 5.14 (KJ/cycle)

Cycle 72 GMT 1/ 2/2016 21:58: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.04 30 14.23 500 213 0.21 / 370.40 6 6
2 1114.08 2 6.00 1830 22 0.24 / 370.42 6 6
3 1918.04 59 10.36 3101 1895 2.13 / 372.31 6 6
4 1510.84 34 12.14 2540 1048 3.18 / 373.36 6 6
5 642.12 34 13.23 1337 601 3.78 / 373.96 6 6
6 86.76 34 14.06 522 250 4.03 / 374.21 6 6
7 48.68 34 14.18 448 216 4.25 / 374.43 6 6
8 -0.08 170 14.17 368 886 5.13 / 375.31 6 17
Average= 5.14 (KJ/cycle)

Cycle 71 GMT 22/ 1/2016 20:58: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.52 30 14.29 482 207 0.21 / 364.38 6 6
2 2001.36 61 12.23 437 326 0.53 / 364.70 6 6
3 2003.52 15 7.68 4187 482 1.01 / 365.18 6 6
4 2006.04 35 10.92 3248 1241 2.26 / 366.42 6 6
5 1853.68 28 12.02 3069 1033 3.29 / 367.46 6 6
6 1450.88 28 12.49 2465 862 4.15 / 368.32 6 6
7 785.16 28 13.15 1528 563 4.71 / 368.88 6 6
8 149.88 28 13.93 632 247 4.96 / 369.13 6 6
9 52.04 29 14.20 446 184 5.14 / 369.31 6 6
10 -0.04 170 14.21 360 870 6.01 / 370.18 6 12
Average= 5.14 (KJ/cycle)

Cycle 70 GMT 12/ 1/2016 20:31: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.52 30 14.29 464 199 0.20 / 358.47 6 6
2 2002.64 61 12.25 437 327 0.53 / 358.80 6 6
3 2005.12 15 8.17 3975 487 1.01 / 359.28 6 6
4 2007.40 36 10.93 3238 1274 2.29 / 360.56 6 6
5 1841.48 29 11.97 3027 1051 3.34 / 361.61 6 6
6 1252.32 29 12.62 2187 800 4.14 / 362.41 6 6
7 580.00 29 13.35 1251 484 4.62 / 362.89 6 6
8 108.80 29 14.05 539 220 4.84 / 363.11 6 6
9 63.68 29 14.20 464 191 5.03 / 363.30 6 6
10 0.04 170 14.23 358 866 5.90 / 364.17 6 18
Average= 5.13 (KJ/cycle)

Cycle 69 GMT 2/ 1/2016 19:54: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.52 30 14.29 500 214 0.21 / 352.58 6 6
2 2002.88 61 12.16 419 311 0.53 / 352.89 6 6
3 2004.88 15 7.97 4062 486 1.01 / 353.37 6 6
4 2006.96 35 10.98 3264 1254 2.27 / 354.63 6 6
5 1842.80 28 12.04 3022 1019 3.28 / 355.65 6 6
6 1442.40 28 12.52 2449 859 4.14 / 356.51 6 6
7 581.60 28 13.40 1257 472 4.61 / 356.98 6 6
8 111.80 29 14.04 557 227 4.84 / 357.20 6 6
9 76.40 29 14.19 483 199 5.04 / 357.40 6 6
10 0.12 170 14.23 358 866 5.91 / 358.27 6 13
Average= 5.12 (KJ/cycle)

Cycle 68 GMT 23/12/2015 18:55: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.52 30 14.36 464 200 0.20 / 346.75 6 6
2 2003.68 61 12.14 437 324 0.52 / 347.08 6 6
3 2005.88 15 8.02 3925 472 1.00 / 347.55 6 6
4 2008.20 36 10.93 3230 1271 2.27 / 348.82 6 6
5 1850.52 28 12.11 3009 1020 3.29 / 349.84 6 6
6 1231.68 29 12.65 2146 787 4.07 / 350.63 6 6
7 579.00 29 13.34 1252 484 4.56 / 351.11 6 6
8 94.04 29 14.10 514 210 4.77 / 351.32 6 6
9 57.96 29 14.21 450 185 4.95 / 351.51 6 6
10 0.04 170 14.22 354 856 5.81 / 352.36 6 20
Average= 5.11 (KJ/cycle)

Cycle 67 GMT 13/12/2015 18:18:59

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.40 30 14.29 482 207 0.21 / 340.98 6 6
2 2001.04 61 12.05 439 323 0.53 / 341.30 6 6
3 2003.36 15 7.86 3764 444 0.97 / 341.75 6 6
4 2005.80 36 10.92 3263 1283 2.26 / 343.03 6 6
5 1829.52 29 12.07 2990 1047 3.30 / 344.07 6 6
6 1229.04 29 12.67 2138 786 4.09 / 344.86 6 6
7 549.96 29 13.39 1209 469 4.56 / 345.33 6 6
8 100.92 29 14.09 518 212 4.77 / 345.54 6 6
9 59.36 29 14.25 447 185 4.95 / 345.73 6 6
10 0.04 170 14.24 342 828 5.78 / 346.55 6 14
Average= 5.10 (KJ/cycle)

Cycle 66 GMT 3/12/2015 17:58: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.88 30 14.36 464 200 0.20 / 334.97 6 6
2 2006.20 61 12.03 436 320 0.52 / 335.29 6 6
3 2008.96 15 7.98 4020 481 1.00 / 335.77 6 6
4 2011.60 36 10.99 3272 1295 2.30 / 337.06 6 6
5 1846.52 29 12.03 3015 1052 3.35 / 338.11 6 6
6 1421.80 28 12.51 2421 848 4.20 / 338.96 6 6
7 745.16 28 13.21 1477 546 4.74 / 339.51 6 6
8 130.56 28 14.00 592 232 4.97 / 339.74 6 6
9 45.40 28 14.27 426 170 5.14 / 339.91 6 6
10 0.04 170 14.23 356 861 6.01 / 340.77 6 13
Average= 5.09 (KJ/cycle)

Cycle 65 GMT 23/11/2015 17:40: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.44 30 14.29 482 207 0.21 / 329.71 6 6
2 2002.16 11 10.47 371 43 0.25 / 329.75 6 6
3 2002.60 6 6.22 3386 126 0.38 / 329.88 6 6
4 2004.80 35 11.27 3268 1289 1.66 / 331.17 6 6
5 1832.60 28 12.10 2967 1005 2.67 / 332.17 6 6
6 1256.20 28 12.70 2174 773 3.44 / 332.95 6 6
7 821.68 28 13.12 1559 573 4.02 / 333.52 6 6
8 108.08 28 14.08 528 208 4.22 / 333.73 6 6
9 58.68 29 14.21 462 190 4.41 / 333.92 6 6
10 0.04 170 14.21 352 850 5.26 / 334.77 6 14
Average= 5.07 (KJ/cycle)

Cycle 64 GMT 13/11/2015 17: 3: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.80 30 14.29 500 214 0.21 / 324.39 6 6
2 2001.44 11 10.38 378 43 0.26 / 324.43 6 6
3 2001.88 6 5.43 3368 110 0.37 / 324.54 6 6
4 2003.96 36 11.27 3256 1321 1.69 / 325.86 6 6
5 1836.12 29 12.04 3025 1056 2.74 / 326.92 6 6
6 1423.20 29 12.50 2386 865 3.61 / 327.78 6 6
7 560.20 29 13.37 1203 466 4.08 / 328.25 6 6
8 94.24 29 14.10 508 208 4.28 / 328.46 6 6
9 56.60 29 14.24 441 182 4.47 / 328.64 6 6
10 0.08 170 14.21 357 862 5.33 / 329.50 6 13
Average= 5.07 (KJ/cycle)

Cycle 63 GMT 3/11/2015 16:46: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.00 29 14.29 482 200 0.20 / 319.04 6 6
2 1035.52 1 11.18 1928 22 0.22 / 319.06 6 6
3 2003.96 11 10.55 374 43 0.26 / 319.10 6 6
4 2004.56 6 5.74 3589 124 0.39 / 319.23 6 6
5 2007.60 36 11.24 3293 1332 1.72 / 320.56 6 6
6 1835.72 29 12.00 3016 1050 2.77 / 321.61 6 6
7 1245.08 29 12.63 2190 802 3.57 / 322.41 6 6
8 620.24 29 13.31 1298 501 4.07 / 322.91 6 6
9 94.72 29 14.11 512 210 4.28 / 323.12 6 6
10 54.32 29 14.21 455 188 4.47 / 323.31 6 6
11 0.04 170 14.19 358 864 5.33 / 324.17 6 15
Average= 5.07 (KJ/cycle)

Cycle 62 GMT 24/10/2015 16:14: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.08 30 14.36 482 208 0.21 / 313.84 6 6
2 952.44 -1 14.36 482 0. 0.00 / 313.84 6 6
3 2001.48 11 10.31 396 45 0.25 / 313.88 6 6
4 2002.12 6 5.58 3362 113 0.37 / 314.00 6 6
5 2005.44 36 11.05 3281 1305 1.67 / 315.30 6 6
6 1835.56 28 12.07 3014 1019 2.69 / 316.32 6 6
7 1231.96 29 12.63 2157 790 3.48 / 317.11 6 6
8 602.72 29 13.36 1246 483 3.96 / 317.59 6 6
9 104.84 29 14.11 512 210 4.17 / 317.80 6 6
10 63.84 29 14.24 440 182 4.35 / 317.99 6 6
11 0.16 170 14.21 354 855 5.21 / 318.84 6 15
Average= 5.06 (KJ/cycle)

Cycle 61 GMT 14/10/2015 15:57: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.16 30 14.29 482 207 0.21 / 308.42 6 6
2 2002.68 11 10.35 385 44 0.25 / 308.46 6 6
3 2003.52 6 5.36 3368 108 0.36 / 308.57 6 6
4 2007.64 35 11.07 3247 1258 1.62 / 309.83 6 6
5 1879.76 28 12.00 3110 1045 2.66 / 310.88 6 6
6 1460.08 28 12.49 2496 873 3.53 / 311.75 6 6
7 798.12 29 13.12 1527 581 4.12 / 312.33 6 6
8 159.92 29 13.94 643 260 4.38 / 312.59 6 6
9 47.12 29 14.25 437 181 4.56 / 312.77 6 6
10 0.12 170 14.20 357 862 5.42 / 313.63 6 10
Average= 5.06 (KJ/cycle)

Cycle 60 GMT 4/10/2015 15:40: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.40 30 14.36 482 208 0.21 / 303.09 6 6
2 2006.52 11 10.53 375 43 0.25 / 303.13 6 6
3 2007.08 6 5.49 3374 111 0.36 / 303.24 6 6
4 2009.72 35 11.06 3230 1250 1.61 / 304.49 6 6
5 1841.44 28 12.09 3009 1019 2.63 / 305.51 6 6
6 1436.80 28 12.54 2437 856 3.49 / 306.36 6 6
7 787.20 28 13.18 1520 561 4.05 / 306.93 6 6
8 156.92 28 13.98 637 249 4.30 / 307.17 6 6
9 50.96 29 14.22 443 183 4.48 / 307.36 6 6
10 0.04 170 14.20 355 857 5.34 / 308.21 6 16
Average= 5.05 (KJ/cycle)

Cycle 59 GMT 24/ 9/2015 15:20: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.44 30 14.36 500 215 0.22 / 298.34 6 6
2 1110.20 5 7.94 1946 77 0.29 / 298.42 6 6
3 1904.12 11 10.02 3117 344 0.64 / 298.76 6 6
4 1891.32 36 11.40 3105 1274 1.91 / 300.04 6 6
5 1507.40 29 12.38 2524 906 2.82 / 300.94 6 6
6 853.16 29 13.10 1603 609 3.43 / 301.55 6 6
7 195.84 29 13.88 696 280 3.71 / 301.83 6 6
8 53.20 29 14.25 446 184 3.89 / 302.02 6 6
9 0.08 170 14.19 357 861 4.75 / 302.88 6 13
Average= 5.05 (KJ/cycle)

Cycle 58 GMT 14/ 9/2015 14:23: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.52 30 14.29 482 207 0.21 / 293.50 6 6
2 1103.76 5 7.98 2011 80 0.29 / 293.58 6 6
3 1907.20 11 9.92 3074 335 0.62 / 293.92 6 6
4 1895.00 35 11.33 3120 1237 1.86 / 295.15 6 6
5 1695.24 28 12.23 2824 967 2.83 / 296.12 6 6
6 1040.68 28 12.92 1871 677 3.50 / 296.80 6 6
7 197.80 29 13.91 705 284 3.79 / 297.08 6 6
8 58.04 28 14.24 462 184 3.97 / 297.27 6 6
9 0.08 170 14.20 356 859 4.83 / 298.13 6 11
Average= 5.05 (KJ/cycle)

Cycle 57 GMT 4/ 9/2015 13:26: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.80 29 14.36 500 208 0.21 / 288.77 6 6
2 1110.12 5 8.42 1910 80 0.29 / 288.85 6 6
3 1885.80 11 9.94 3099 339 0.63 / 289.19 6 6
4 1870.00 36 11.39 3051 1251 1.88 / 290.44 6 6
5 1500.16 29 12.39 2512 903 2.78 / 291.35 6 6
6 890.20 29 13.06 1658 628 3.41 / 291.97 6 6
7 193.68 29 13.91 684 276 3.68 / 292.25 6 6
8 59.36 29 14.25 441 182 3.87 / 292.43 6 6
9 0.16 170 14.20 357 862 4.73 / 293.29 6 13
Average= 5.06 (KJ/cycle)

Cycle 56 GMT 25/ 8/2015 12:28: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.92 30 14.36 500 215 0.22 / 284.04 6 6
2 972.56 -1 14.36 500 0. 0.00 / 284.04 6 6
3 1031.16 1 11.75 1928 23 0.24 / 284.06 6 6
4 1107.16 5 8.34 1904 79 0.32 / 284.14 6 6
5 1902.88 11 9.88 3092 336 0.65 / 284.48 6 6
6 1886.72 36 11.36 3089 1263 1.92 / 285.74 6 6
7 1519.04 29 12.35 2562 918 2.83 / 286.66 6 6
8 893.40 29 13.08 1637 621 3.46 / 287.28 6 6
9 137.16 29 14.03 593 241 3.70 / 287.52 6 6
10 43.76 29 14.28 435 180 3.88 / 287.70 6 6
11 0.16 170 14.20 359 867 4.74 / 288.57 6 14
Average= 5.06 (KJ/cycle)

Cycle 55 GMT 15/ 8/2015 11:21: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.24 30 14.36 500 215 0.22 / 279.33 6 6
2 1118.60 5 8.62 1946 84 0.30 / 279.42 6 6
3 1880.16 11 10.00 3035 334 0.63 / 279.75 6 6
4 1866.56 36 11.37 3039 1244 1.88 / 281.00 6 6
5 1464.44 29 12.43 2498 900 2.78 / 281.90 6 6
6 868.36 29 13.08 1648 625 3.40 / 282.52 6 6
7 129.60 29 14.02 601 244 3.65 / 282.77 6 6
8 34.64 29 14.29 423 175 3.82 / 282.94 6 6
9 0.08 170 14.16 366 881 4.70 / 283.82 6 12
Average= 5.07 (KJ/cycle)

Cycle 54 GMT 5/ 8/2015 10:12: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.32 30 14.36 500 215 0.22 / 274.74 6 6
2 1108.64 5 8.66 1940 84 0.30 / 274.83 6 6
3 1864.52 11 10.34 2985 340 0.64 / 275.17 6 6
4 1851.24 35 11.38 3027 1206 1.84 / 276.37 6 6
5 1460.04 28 12.52 2407 844 2.69 / 277.22 6 6
6 828.12 28 13.16 1564 576 3.26 / 277.79 6 6
7 185.12 28 13.96 679 265 3.53 / 278.06 6 6
8 59.24 28 14.25 460 184 3.71 / 278.24 6 6
9 0.04 170 14.18 364 877 4.59 / 279.12 6 16
Average= 5.07 (KJ/cycle)

Cycle 53 GMT 26/ 7/2015 9:14: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.64 30 14.36 500 215 0.22 / 269.77 6 6
2 1209.12 5 8.49 2053 87 0.30 / 269.86 6 6
3 1992.24 11 10.21 3167 356 0.66 / 270.21 6 6
4 1977.44 36 11.29 3168 1288 1.95 / 271.50 6 6
5 1613.00 29 12.30 2657 948 2.89 / 272.45 6 6
6 1001.16 29 12.99 1760 663 3.56 / 273.11 6 6
7 327.68 29 13.72 873 347 3.90 / 273.46 6 6
8 76.80 29 14.19 482 198 4.10 / 273.66 6 6
9 0.16 170 14.18 361 870 4.97 / 274.53 6 12
Average= 5.08 (KJ/cycle)

Cycle 52 GMT 16/ 7/2015 7:54: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.92 30 14.36 500 215 0.22 / 264.80 6 6
2 1223.76 5 8.28 2107 87 0.30 / 264.89 6 6
3 1995.76 11 10.53 3145 364 0.67 / 265.25 6 6
4 1984.48 36 11.40 3182 1306 1.97 / 266.56 6 6
5 1591.32 29 12.34 2621 938 2.91 / 267.50 6 6
6 956.92 29 13.02 1749 660 3.57 / 268.16 6 6
7 280.08 29 13.79 836 334 3.91 / 268.49 6 6
8 63.52 29 14.20 474 195 4.10 / 268.69 6 6
9 0.08 170 14.18 361 870 4.97 / 269.56 6 13
Average= 5.09 (KJ/cycle)

Cycle 51 GMT 6/ 7/2015 6:45: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.64 30 14.29 500 214 0.21 / 260.00 6 6
2 1107.44 5 8.53 1910 81 0.30 / 260.08 6 6
3 1862.76 11 10.25 3042 343 0.64 / 260.42 6 6
4 1850.12 36 11.49 3020 1249 1.89 / 261.67 6 6
5 1655.84 29 12.28 2748 979 2.87 / 262.65 6 6
6 818.64 29 13.11 1584 602 3.47 / 263.25 6 6
7 173.08 29 13.96 676 274 3.74 / 263.53 6 6
8 55.64 29 14.27 453 187 3.93 / 263.72 6 6
9 0.00 170 14.20 360 869 4.80 / 264.58 6 13
Average= 5.09 (KJ/cycle)

Cycle 50 GMT 26/ 6/2015 5:51: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.96 30 14.36 500 215 0.22 / 254.48 6 6
2 2000.88 35 9.67 3524 1193 1.41 / 255.67 6 6
3 1870.16 28 12.17 3105 1058 2.47 / 256.73 6 6
4 1679.28 28 12.41 2796 972 3.44 / 257.70 6 6
5 1000.60 28 13.02 1832 668 4.11 / 258.37 6 6
6 320.24 29 13.75 889 354 4.46 / 258.72 6 6
7 79.76 29 14.18 496 204 4.66 / 258.92 6 6
8 0.04 170 14.20 357 862 5.53 / 259.79 6 12
Average= 5.09 (KJ/cycle)

Cycle 49 GMT 16/ 6/2015 5:39: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.52 30 14.36 500 215 0.22 / 249.20 6 6
2 2003.36 35 9.80 3472 1191 1.41 / 250.39 6 6
3 1872.36 28 12.13 3100 1053 2.46 / 251.45 6 6
4 1488.24 28 12.58 2507 883 3.34 / 252.33 6 6
5 854.36 28 13.16 1624 598 3.94 / 252.93 6 6
6 184.08 29 13.96 678 274 4.22 / 253.20 6 6
7 65.00 29 14.26 461 191 4.41 / 253.39 6 6
8 0.04 170 14.20 359 867 5.27 / 254.26 6 11
Average= 5.09 (KJ/cycle)

Cycle 48 GMT 6/ 6/2015 5: 3: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.68 29 14.36 500 208 0.21 / 244.06 6 6
2 1873.20 35 10.48 3163 1160 1.37 / 245.22 6 6
3 1735.76 28 12.25 2906 997 2.37 / 246.22 6 6
4 1541.60 28 12.55 2584 908 3.27 / 247.13 6 6
5 860.56 28 13.20 1614 597 3.87 / 247.72 6 6
6 122.48 28 14.13 553 219 4.09 / 247.94 6 6
7 72.92 29 14.27 473 196 4.28 / 248.14 6 6
8 0.08 170 14.22 351 849 5.13 / 248.99 6 14
Average= 5.08 (KJ/cycle)

Cycle 47 GMT 27/ 5/2015 4: 6: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.44 29 14.42 482 202 0.20 / 239.22 6 6
2 1619.72 35 10.52 3072 1131 1.33 / 240.35 6 6
3 1539.20 28 12.52 2559 897 2.23 / 241.24 6 6
4 1361.96 28 12.75 2309 824 3.05 / 242.07 6 6
5 553.00 28 13.52 1230 466 3.52 / 242.53 6 6
6 144.64 29 14.02 630 256 3.78 / 242.79 6 6
7 43.44 28 14.32 436 175 3.95 / 242.97 6 6
8 0.04 170 14.18 369 890 4.84 / 243.85 6 16
Average= 5.08 (KJ/cycle)

Cycle 46 GMT 17/ 5/2015 3:34: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.12 29 14.42 500 209 0.21 / 234.40 6 6
2 1680.92 35 10.63 3022 1124 1.33 / 235.53 6 6
3 1579.20 28 12.48 2619 915 2.25 / 236.44 6 6
4 1381.20 28 12.75 2314 826 3.07 / 237.27 6 6
5 541.76 29 13.54 1167 458 3.53 / 237.73 6 6
6 115.52 29 14.15 548 225 3.76 / 237.95 6 6
7 71.08 29 14.30 471 195 3.95 / 238.15 6 6
8 0.16 170 14.24 359 869 4.82 / 239.01 6 17
Average= 5.09 (KJ/cycle)

Cycle 45 GMT 7/ 5/2015 2:51: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.52 29 14.36 517 215 0.22 / 229.36 6 6
2 1782.40 35 10.81 3160 1196 1.41 / 230.56 6 6
3 1667.44 20 12.64 2762 698 2.11 / 231.25 6 6
4 1504.96 20 12.81 2510 643 2.75 / 231.90 6 6
5 1287.52 20 13.04 2167 565 3.32 / 232.46 6 6
6 816.80 20 13.40 1515 406 3.72 / 232.87 6 6
7 177.92 20 14.07 651 183 3.91 / 233.05 6 6
8 107.20 20 14.23 530 151 4.06 / 233.20 6 6
9 56.40 21 14.33 446 134 4.19 / 233.34 6 6
10 0.00 170 14.25 353 855 5.05 / 234.19 6 11
Average= 5.09 (KJ/cycle)

Cycle 44 GMT 27/ 4/2015 1:58: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.84 29 14.42 500 209 0.21 / 224.06 6 6
2 2002.72 35 10.88 3370 1283 1.49 / 225.34 6 6
3 1848.96 20 12.49 3046 761 2.25 / 226.10 6 6
4 1638.84 20 12.77 2691 687 2.94 / 226.79 6 6
5 1423.84 20 12.96 2417 626 3.57 / 227.42 6 6
6 721.44 20 13.47 1432 386 3.95 / 227.80 6 6
7 164.88 21 14.08 650 192 4.15 / 228.00 6 6
8 100.52 21 14.27 523 157 4.30 / 228.15 6 6
9 47.00 21 14.36 432 130 4.43 / 228.28 6 6
10 0.12 170 14.21 357 862 5.29 / 229.15 6 16
Average= 5.09 (KJ/cycle)

Cycle 43 GMT 17/ 4/2015 1:49: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.64 29 14.48 482 202 0.20 / 218.81 6 6
2 2000.64 35 11.10 3315 1288 1.49 / 220.10 6 6
3 1852.80 20 12.57 3066 771 2.26 / 220.87 6 6
4 1659.72 20 12.78 2727 697 2.96 / 221.57 6 6
5 1216.76 20 13.11 2093 549 3.51 / 222.12 6 6
6 770.08 20 13.47 1457 393 3.90 / 222.51 6 6
7 176.72 21 14.08 646 191 4.09 / 222.70 6 6
8 100.00 21 14.25 525 157 4.25 / 222.86 6 6
9 46.20 20 14.37 434 125 4.37 / 222.98 6 6
10 0.08 170 14.20 359 867 5.24 / 223.85 6 12
Average= 5.09 (KJ/cycle)

Cycle 42 GMT 7/ 4/2015 1:29: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.56 29 14.42 464 194 0.19 / 213.57 6 6
2 2001.16 35 11.12 3395 1321 1.52 / 214.89 6 6
3 1842.16 20 12.63 2972 751 2.27 / 215.64 6 6
4 1630.52 20 12.84 2671 686 2.95 / 216.33 6 6
5 1416.12 20 12.99 2399 623 3.58 / 216.95 6 6
6 706.72 20 13.52 1401 379 3.95 / 217.33 6 6
7 145.24 20 14.13 613 173 4.13 / 217.50 6 6
8 95.84 20 14.28 517 148 4.27 / 217.65 6 6
9 51.68 20 14.39 430 124 4.40 / 217.77 6 6
10 0.16 170 14.24 346 838 5.24 / 218.61 6 11
Average= 5.08 (KJ/cycle)

Cycle 41 GMT 28/ 3/2015 1:17: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.20 29 14.48 500 210 0.21 / 208.43 6 6
2 2001.60 35 11.53 3324 1341 1.55 / 209.77 6 6
3 1822.04 20 12.69 3001 762 2.31 / 210.54 6 6
4 1614.60 20 12.88 2651 683 3.00 / 211.22 6 6
5 1191.12 20 13.17 2066 544 3.54 / 211.76 6 6
6 719.12 20 13.54 1405 380 3.92 / 212.14 6 6
7 139.88 21 14.19 575 171 4.09 / 212.31 6 6
8 87.04 20 14.32 493 141 4.23 / 212.46 6 6
9 43.32 21 14.39 404 122 4.36 / 212.58 6 6
10 0.04 170 14.26 329 798 5.15 / 213.38 6 17
Average= 5.08 (KJ/cycle)

Cycle 40 GMT 18/ 3/2015 0:53: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.48 29 14.48 482 202 0.20 / 203.09 6 6
2 2001.84 36 11.48 3440 1422 1.62 / 204.51 6 6
3 1845.24 21 12.64 3001 797 2.42 / 205.31 6 6
4 1645.00 21 12.82 2701 727 3.15 / 206.04 6 6
5 994.28 21 13.28 1823 508 3.66 / 206.54 6 6
6 556.36 21 13.64 1247 357 4.01 / 206.90 6 6
7 144.40 20 14.18 624 177 4.19 / 207.08 6 6
8 85.72 20 14.35 504 145 4.34 / 207.22 6 6
9 40.64 20 14.40 428 123 4.46 / 207.35 6 6
10 0.08 170 14.22 363 878 5.34 / 208.22 6 15
Average= 5.08 (KJ/cycle)

Cycle 39 GMT 8/ 3/2015 0:41: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.96 29 14.42 517 216 0.22 / 197.71 6 6
2 2006.32 36 11.82 3385 1440 1.66 / 199.15 6 6
3 1840.68 21 12.71 2989 798 2.45 / 199.95 6 6
4 1433.60 21 12.98 2475 675 3.13 / 200.63 6 6
5 1214.44 21 13.15 2118 585 3.71 / 201.21 6 6
6 509.00 21 13.73 1160 334 4.05 / 201.55 6 6
7 138.72 21 14.21 615 184 4.23 / 201.73 6 6
8 77.36 21 14.33 501 151 4.38 / 201.88 6 6
9 14.28 21 14.43 396 120 4.50 / 202.00 6 6
10 0.16 170 14.19 368 888 5.39 / 202.89 6 19
Average= 5.07 (KJ/cycle)

Cycle 38 GMT 26/ 2/2015 0:32: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.68 29 14.48 482 202 0.20 / 192.44 6 6
2 2004.56 36 11.73 3381 1428 1.63 / 193.87 6 6
3 1835.64 21 12.73 2997 801 2.43 / 194.67 6 6
4 1627.88 21 12.88 2702 731 3.16 / 195.40 6 6
5 1146.88 21 13.23 2041 567 3.73 / 195.97 6 6
6 448.64 21 13.81 1081 314 4.04 / 196.28 6 6
7 118.76 21 14.25 579 173 4.22 / 196.46 6 6
8 67.68 21 14.35 486 146 4.36 / 196.60 6 6
9 0.16 170 14.23 370 895 5.26 / 197.50 6 9
Average= 5.06 (KJ/cycle)

Cycle 37 GMT 16/ 2/2015 0:19: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.52 29 14.48 500 210 0.21 / 187.03 6 6
2 2003.24 36 11.90 3375 1446 1.66 / 188.47 6 6
3 1845.20 20 12.76 3042 776 2.43 / 189.25 6 6
4 1636.92 20 12.97 2698 700 3.13 / 189.95 6 6
5 1197.64 20 13.24 2097 555 3.69 / 190.50 6 6
6 736.36 20 13.60 1455 396 4.08 / 190.90 6 6
7 145.20 20 14.20 633 180 4.26 / 191.08 6 6
8 87.56 20 14.36 519 149 4.41 / 191.23 6 6
9 47.32 20 14.41 448 129 4.54 / 191.36 6 6
10 0.12 170 14.23 365 883 5.42 / 192.24 6 15
Average= 5.06 (KJ/cycle)

Cycle 36 GMT 6/ 2/2015 0: 6: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.16 29 14.48 482 202 0.20 / 181.80 6 6
2 2004.88 36 12.01 3354 1450 1.65 / 183.25 6 6
3 1840.44 20 12.85 2970 763 2.42 / 184.01 6 6
4 1430.48 20 13.14 2374 624 3.04 / 184.63 6 6
5 1215.88 20 13.28 2062 548 3.59 / 185.18 6 6
6 517.84 20 13.81 1135 313 3.90 / 185.49 6 6
7 145.08 20 14.26 598 171 4.07 / 185.66 6 6
8 86.76 20 14.38 497 143 4.21 / 185.81 6 6
9 43.60 20 14.42 425 123 4.34 / 185.93 6 6
10 0.04 170 14.23 366 885 5.22 / 186.82 6 19
Average= 5.05 (KJ/cycle)

Cycle 35 GMT 26/ 1/2015 23:57: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.32 29 14.55 482 203 0.20 / 176.46 6 6
2 2002.32 36 12.31 3305 1465 1.67 / 177.93 6 6
3 1836.92 20 12.84 2995 769 2.44 / 178.70 6 6
4 1617.48 20 13.00 2693 700 3.14 / 179.40 6 6
5 1176.20 20 13.30 2079 553 3.69 / 179.95 6 6
6 489.88 20 13.86 1129 313 4.00 / 180.26 6 6
7 132.72 20 14.28 611 175 4.18 / 180.44 6 6
8 78.52 20 14.38 506 146 4.32 / 180.58 6 6
9 40.20 20 14.43 432 125 4.45 / 180.71 6 6
10 0.08 170 14.23 366 885 5.33 / 181.59 6 15
Average= 5.04 (KJ/cycle)

Cycle 34 GMT 16/ 1/2015 23:35: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.52 29 14.48 500 210 0.21 / 171.25 6 6
2 2002.44 36 12.31 3303 1464 1.67 / 172.72 6 6
3 1829.36 20 12.87 2959 762 2.44 / 173.48 6 6
4 1611.36 20 13.00 2675 695 3.13 / 174.18 6 6
5 936.16 20 13.47 1709 460 3.59 / 174.64 6 6
6 470.20 20 13.90 1080 300 3.89 / 174.94 6 6
7 129.00 20 14.29 591 169 4.06 / 175.11 6 6
8 71.88 20 14.38 486 140 4.20 / 175.25 6 6
9 34.52 20 14.43 425 123 4.32 / 175.37 6 6
10 0.04 170 14.22 369 892 5.21 / 176.26 6 19
Average= 5.04 (KJ/cycle)

Cycle 33 GMT 6/ 1/2015 23:21: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.68 29 14.55 500 211 0.21 / 166.26 6 6
2 1890.12 36 12.41 3186 1423 1.63 / 167.68 6 6
3 1727.44 20 12.91 2903 750 2.38 / 168.43 6 6
4 1512.60 20 13.04 2586 674 3.06 / 169.10 6 6
5 1043.92 20 13.42 1890 507 3.57 / 169.61 6 6
6 361.80 20 13.99 959 268 3.83 / 169.88 6 6
7 115.12 20 14.36 559 161 3.99 / 170.04 6 6
8 75.44 20 14.44 482 139 4.13 / 170.18 6 6
9 0.12 170 14.31 356 866 5.00 / 171.04 6 11
Average= 5.03 (KJ/cycle)

Cycle 32 GMT 27/12/2014 22:26:58

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.60 29 14.55 500 211 0.21 / 161.59 6 6
2 1721.72 36 12.77 2840 1306 1.52 / 162.89 6 6
3 1570.68 20 13.03 2638 687 2.20 / 163.58 6 6
4 1372.24 20 13.16 2332 614 2.82 / 164.19 6 6
5 926.48 20 13.51 1693 457 3.28 / 164.65 6 6
6 242.04 20 14.14 778 220 3.50 / 164.87 6 6
7 121.16 20 14.32 591 169 3.66 / 165.04 6 6
8 65.64 20 14.40 479 138 3.80 / 165.18 6 6
9 0.12 170 14.26 357 865 4.67 / 166.05 6 13
Average= 5.03 (KJ/cycle)

Cycle 31 GMT 17/12/2014 21:59: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.76 29 14.48 500 210 0.21 / 156.77 6 6
2 1818.52 36 12.48 3043 1367 1.58 / 158.13 6 6
3 1653.20 20 13.03 2736 713 2.29 / 158.85 6 6
4 1456.40 20 13.13 2448 643 2.93 / 159.49 6 6
5 804.68 20 13.62 1535 418 3.35 / 159.91 6 6
6 363.68 20 14.01 961 269 3.62 / 160.18 6 6
7 145.52 20 14.30 633 181 3.80 / 160.36 6 6
8 73.80 20 14.42 495 143 3.94 / 160.50 6 6
9 0.12 170 14.26 361 875 4.82 / 161.38 6 11
Average= 5.04 (KJ/cycle)

Cycle 30 GMT 7/12/2014 21:11: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.40 29 14.55 500 211 0.21 / 151.62 6 6
2 2004.00 36 12.38 3255 1451 1.66 / 153.07 6 6
3 1815.24 20 12.91 2939 759 2.42 / 153.83 6 6
4 1401.72 20 13.18 2363 623 3.04 / 154.45 6 6
5 973.36 20 13.49 1814 489 3.53 / 154.94 6 6
6 519.52 20 13.89 1140 317 3.85 / 155.26 6 6
7 142.24 20 14.30 613 175 4.02 / 155.43 6 6
8 73.40 20 14.41 493 142 4.17 / 155.57 6 6
9 14.84 20 14.53 387 112 4.28 / 155.69 6 6
10 0.08 170 14.21 361 872 5.15 / 156.56 6 19
Average= 5.05 (KJ/cycle)

Cycle 29 GMT 27/11/2014 20:51: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.20 29 14.55 500 211 0.21 / 146.49 6 6
2 2005.72 36 12.46 3278 1470 1.68 / 147.97 6 6
3 1813.44 20 12.88 2932 755 2.44 / 148.72 6 6
4 1390.60 20 13.19 2334 616 3.05 / 149.34 6 6
5 948.08 20 13.56 1702 462 3.51 / 149.80 6 6
6 492.00 20 13.91 1102 307 3.82 / 150.10 6 6
7 138.80 20 14.35 573 164 3.98 / 150.27 6 6
8 70.24 20 14.46 477 138 4.12 / 150.41 6 6
9 32.88 20 14.47 416 120 4.24 / 150.53 6 6
10 0.04 170 14.25 363 879 5.12 / 151.41 6 17
Average= 5.05 (KJ/cycle)

Cycle 28 GMT 17/11/2014 20:37: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.40 28 14.55 517 211 0.21 / 141.30 6 6
2 1023.24 1 13.91 1910 27 0.24 / 141.32 6 6
3 2009.92 36 12.39 3325 1483 1.72 / 142.81 6 6
4 1829.12 20 12.89 2957 762 2.48 / 143.57 6 6
5 1403.36 20 13.17 2408 634 3.12 / 144.20 6 6
6 963.48 20 13.52 1745 472 3.59 / 144.67 6 6
7 509.04 20 13.88 1155 321 3.91 / 144.99 6 6
8 140.20 20 14.34 609 175 4.08 / 145.17 6 6
9 74.52 20 14.44 484 140 4.22 / 145.31 6 6
10 34.88 20 14.47 414 120 4.34 / 145.43 6 6
11 0.08 170 14.25 353 855 5.20 / 146.28 6 16
Average= 5.04 (KJ/cycle)

Cycle 27 GMT 7/11/2014 20:18: 3

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.92 28 14.48 517 210 0.21 / 136.80 6 6
2 1665.56 36 12.68 2772 1265 1.47 / 138.07 6 6
3 1518.08 20 13.08 2515 658 2.13 / 138.73 6 6
4 1336.88 20 13.22 2236 591 2.72 / 139.32 6 6
5 715.16 20 13.70 1412 387 3.11 / 139.70 6 6
6 267.84 20 14.15 816 231 3.34 / 139.93 6 6
7 130.84 20 14.37 564 162 3.50 / 140.10 6 6
8 61.92 20 14.46 459 133 3.64 / 140.23 6 6
9 0.12 170 14.26 353 856 4.49 / 141.09 6 13
Average= 5.04 (KJ/cycle)

Cycle 26 GMT 28/10/2014 19:48:59

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.48 28 14.55 500 204 0.20 / 131.73 6 6
2 1851.48 36 12.72 3043 1393 1.60 / 133.13 6 6
3 1676.20 20 12.98 2745 713 2.31 / 133.84 6 6
4 1461.24 20 13.18 2430 641 2.95 / 134.48 6 6
5 1003.84 20 13.51 1796 485 3.44 / 134.97 6 6
6 538.24 20 13.89 1166 324 3.76 / 135.29 6 6
7 143.76 20 14.35 589 169 3.93 / 135.46 6 6
8 72.28 20 14.47 475 137 4.07 / 135.60 6 6
9 36.16 20 14.49 416 121 4.19 / 135.72 6 6
10 0.00 170 14.24 362 876 5.06 / 136.59 6 16
Average= 5.06 (KJ/cycle)

Cycle 25 GMT 18/10/2014 19:10:59

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.68 28 14.55 500 204 0.20 / 126.76 6 6
2 2001.08 36 12.47 3222 1446 1.65 / 128.21 6 6
3 1836.60 20 12.86 2954 760 2.41 / 128.97 6 6
4 1407.72 20 13.15 2394 630 3.04 / 129.60 6 6
5 966.12 20 13.51 1774 479 3.52 / 130.08 6 6
6 309.72 20 14.10 883 249 3.77 / 130.33 6 6
7 149.92 20 14.34 613 176 3.94 / 130.50 6 6
8 72.96 20 14.45 486 140 4.08 / 130.65 6 6
9 -0.08 170 14.25 365 884 4.97 / 131.53 6 12
Average= 5.06 (KJ/cycle)

Cycle 24 GMT 8/10/2014 18:41: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.92 28 14.55 500 204 0.20 / 121.45 6 6
2 2003.12 36 12.49 3248 1460 1.66 / 122.91 6 6
3 1810.08 20 12.87 2970 764 2.43 / 123.67 6 6
4 1604.88 20 13.01 2647 689 3.12 / 124.36 6 6
5 932.00 20 13.55 1682 456 3.57 / 124.82 6 6
6 468.44 20 13.95 1057 295 3.87 / 125.11 6 6
7 123.72 20 14.38 557 160 4.03 / 125.27 6 6
8 65.68 20 14.45 477 138 4.17 / 125.41 6 6
9 13.88 20 14.51 394 114 4.28 / 125.53 6 6
10 0.08 201 14.18 363 1035 5.32 / 126.56 6 20
Average= 5.06 (KJ/cycle)

Cycle 23 GMT 28/ 9/2014 18:27: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.76 28 14.61 500 205 0.20 / 116.05 6 6
2 2006.84 36 12.48 3221 1447 1.65 / 117.49 6 6
3 1860.32 20 12.83 2981 765 2.42 / 118.26 6 6
4 1664.56 20 12.96 2740 710 3.13 / 118.97 6 6
5 1222.04 20 13.30 2088 555 3.68 / 119.52 6 6
6 359.76 20 14.07 925 260 3.94 / 119.78 6 6
7 165.56 20 14.34 609 175 4.12 / 119.96 6 6
8 74.92 20 14.48 450 130 4.25 / 120.09 6 6
9 15.24 20 14.55 376 109 4.36 / 120.20 6 6
10 0.00 200 14.17 370 1049 5.41 / 121.25 6 28
Average= 5.05 (KJ/cycle)

Cycle 22 GMT 18/ 9/2014 17:51: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.00 28 14.55 517 211 0.21 / 110.69 6 6
2 2001.92 36 12.54 3337 1506 1.72 / 112.20 6 6
3 1805.72 21 12.86 2924 790 2.51 / 112.99 6 6
4 1595.00 20 13.07 2602 680 3.19 / 113.67 6 6
5 891.80 20 13.59 1633 444 3.63 / 114.11 6 6
6 431.96 20 13.99 1017 285 3.92 / 114.40 6 6
7 121.52 20 14.42 535 154 4.07 / 114.55 6 6
8 57.08 20 14.50 443 128 4.20 / 114.68 6 6
9 30.32 20 14.49 410 119 4.32 / 114.80 6 6
10 0.12 201 14.21 364 1040 5.36 / 115.84 6 21
Average= 5.04 (KJ/cycle)

Cycle 21 GMT 8/ 9/2014 17:27: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.60 28 14.55 500 204 0.20 / 104.99 6 6
2 2001.92 36 11.80 3629 1542 1.75 / 106.53 6 6
3 1861.12 21 12.81 3037 817 2.56 / 107.34 6 6
4 1670.52 20 13.00 2758 717 3.28 / 108.06 6 6
5 1228.48 20 13.34 2111 563 3.84 / 108.62 6 6
6 750.68 20 13.69 1430 392 4.23 / 109.02 6 6
7 160.04 20 14.34 618 177 4.41 / 109.19 6 6
8 92.04 20 14.47 482 139 4.55 / 109.33 6 6
9 43.16 20 14.54 423 123 4.67 / 109.46 6 6
10 0.04 201 14.22 360 1029 5.70 / 110.48 6 18
Average= 5.02 (KJ/cycle)

Cycle 20 GMT 29/ 8/2014 17: 6: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.68 28 14.61 482 197 0.20 / 99.77 6 6
2 2003.60 36 12.45 3262 1462 1.66 / 101.23 6 6
3 1831.32 21 12.81 2946 793 2.45 / 102.02 6 6
4 1614.12 20 13.04 2646 690 3.14 / 102.71 6 6
5 951.36 20 13.51 1740 470 3.61 / 103.18 6 6
6 311.24 20 14.07 883 248 3.86 / 103.43 6 6
7 146.80 20 14.31 629 180 4.04 / 103.61 6 6
8 74.80 20 14.42 491 142 4.18 / 103.75 6 6
9 0.08 201 14.17 362 1031 5.21 / 104.78 6 16
Average= 4.99 (KJ/cycle)

Cycle 19 GMT 19/ 8/2014 16:33: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.68 27 14.48 517 202 0.20 / 94.63 6 6
2 2002.20 36 12.55 3261 1473 1.68 / 96.10 6 6
3 1831.80 21 12.79 2961 795 2.47 / 96.90 6 6
4 1623.48 20 12.97 2662 691 3.16 / 97.59 6 6
5 927.56 20 13.54 1669 452 3.61 / 98.04 6 6
6 462.52 20 13.94 1048 292 3.91 / 98.33 6 6
7 121.48 20 14.39 528 152 4.06 / 98.48 6 6
8 61.12 20 14.49 428 124 4.18 / 98.61 6 6
9 0.08 201 14.23 336 961 5.14 / 99.57 6 21
Average= 4.98 (KJ/cycle)

Cycle 18 GMT 9/ 8/2014 16:23: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.32 28 14.48 517 210 0.21 / 89.47 6 6
2 973.00 -1 14.48 517 0. 0.00 / 89.47 6 6
3 1023.44 1 14.29 1946 28 0.24 / 89.50 6 6
4 2005.60 36 12.53 3295 1486 1.72 / 90.98 6 6
5 1827.68 21 12.74 2960 792 2.52 / 91.78 6 6
6 1402.52 20 13.11 2381 624 3.14 / 92.40 6 6
7 968.68 20 13.47 1747 471 3.61 / 92.87 6 6
8 305.36 20 14.07 861 242 3.85 / 93.11 6 6
9 141.32 20 14.33 577 165 4.02 / 93.28 6 6
10 66.12 20 14.46 448 130 4.15 / 93.41 6 6
11 0.04 201 14.17 357 1017 5.16 / 94.43 6 14
Average= 4.97 (KJ/cycle)

Cycle 17 GMT 30/ 7/2014 16: 1: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.56 28 14.48 517 210 0.21 / 84.37 6 6
2 2001.52 36 12.67 3191 1455 1.67 / 85.82 6 6
3 1827.00 21 12.74 2938 786 2.45 / 86.61 6 6
4 1394.80 20 13.13 2321 609 3.06 / 87.22 6 6
5 767.16 20 13.62 1477 402 3.46 / 87.62 6 6
6 326.72 20 14.04 890 250 3.71 / 87.87 6 6
7 83.92 20 14.46 482 139 3.85 / 88.01 6 6
8 48.64 20 14.48 428 124 3.98 / 88.13 6 6
9 9.64 20 14.54 361 105 4.08 / 88.24 6 6
10 0.20 201 14.12 361 1025 5.11 / 89.26 6 25
Average= 4.96 (KJ/cycle)

Cycle 16 GMT 20/ 7/2014 15:28: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.12 28 14.61 500 205 0.20 / 79.21 6 6
2 2002.68 36 12.69 3215 1469 1.67 / 80.68 6 6
3 1820.48 21 12.74 2944 788 2.46 / 81.47 6 6
4 1383.92 20 13.14 2329 612 3.07 / 82.08 6 6
5 933.36 20 13.49 1698 458 3.53 / 82.54 6 6
6 480.60 20 13.90 1082 301 3.83 / 82.84 6 6
7 116.20 20 14.40 546 157 3.99 / 82.99 6 6
8 58.12 20 14.47 452 131 4.12 / 83.13 6 6
9 0.16 201 14.16 362 1030 5.15 / 84.16 6 22
Average= 4.95 (KJ/cycle)

Cycle 15 GMT 10/ 7/2014 15: 2: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.00 26 14.61 517 196 0.20 / 74.09 6 6
2 1070.28 2 14.48 1982 57 0.25 / 74.15 6 6
3 2004.88 36 12.73 3207 1470 1.72 / 75.62 6 6
4 1820.24 21 12.75 2950 790 2.51 / 76.41 6 6
5 1390.92 20 13.14 2345 616 3.13 / 77.02 6 6
6 936.36 20 13.51 1709 462 3.59 / 77.49 6 6
7 266.96 20 14.14 798 226 3.82 / 77.71 6 6
8 120.96 20 14.39 537 155 3.97 / 77.87 6 6
9 28.88 20 14.58 385 112 4.08 / 77.98 6 6
10 0.04 201 14.15 361 1027 5.11 / 79.01 6 22
Average= 4.94 (KJ/cycle)

Cycle 14 GMT 30/ 6/2014 14:39: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.36 26 14.61 500 190 0.19 / 69.11 6 6
2 2001.32 36 12.73 3200 1466 1.66 / 70.58 6 6
3 1816.72 21 12.80 2924 786 2.44 / 71.37 6 6
4 1387.32 20 13.16 2327 612 3.05 / 71.98 6 6
5 926.92 20 13.55 1669 452 3.51 / 72.43 6 6
6 254.12 20 14.22 767 218 3.73 / 72.65 6 6
7 61.28 20 14.58 437 127 3.85 / 72.78 6 6
8 31.32 20 14.55 392 114 3.97 / 72.89 6 6
9 0.08 201 14.18 352 1003 4.97 / 73.89 6 17
Average= 4.93 (KJ/cycle)

Cycle 13 GMT 20/ 6/2014 14:26: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.24 26 14.68 500 191 0.19 / 63.55 6 6
2 2002.08 70 12.22 3275 2801 2.99 / 66.36 6 6
3 1086.44 25 13.26 1981 657 3.65 / 67.01 6 6
4 404.04 25 13.92 994 346 3.99 / 67.36 6 6
5 85.00 25 14.46 482 174 4.17 / 67.53 6 6
6 39.88 25 14.52 399 145 4.31 / 67.68 6 6
7 0.16 251 14.16 351 1248 5.56 / 68.92 6 78
Average= 4.92 (KJ/cycle)

Cycle 12 GMT 10/ 6/2014 14:29: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.16 26 14.61 517 196 0.20 / 58.05 6 6
2 2001.00 70 12.26 3271 2807 3.00 / 60.85 6 6
3 1024.68 25 13.30 1837 611 3.61 / 61.46 6 6
4 332.96 25 14.01 906 317 3.93 / 61.78 6 6
5 88.68 25 14.50 474 172 4.10 / 61.95 6 6
6 17.24 25 14.62 357 130 4.23 / 62.08 6 6
7 0.08 251 14.15 360 1279 5.51 / 63.36 6 75
Average= 4.87 (KJ/cycle)

Cycle 11 GMT 31/ 5/2014 14:26: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.80 26 14.68 500 191 0.19 / 52.29 6 6
2 2006.76 70 12.27 3292 2827 3.02 / 55.11 6 6
3 1264.00 25 13.12 2210 725 3.74 / 55.84 6 6
4 533.40 25 13.80 1163 401 4.14 / 56.24 6 6
5 76.80 25 14.51 465 169 4.31 / 56.41 6 6
6 37.08 25 14.52 410 149 4.46 / 56.56 6 6
7 0.12 251 14.15 364 1293 5.75 / 57.85 6 63
Average= 4.82 (KJ/cycle)

Cycle 10 GMT 21/ 5/2014 14: 3: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.04 25 14.74 500 184 0.18 / 46.67 6 6
2 2003.00 70 12.31 3265 2813 3.00 / 49.49 6 6
3 1246.72 25 13.16 2153 708 3.71 / 50.19 6 6
4 336.32 25 14.05 913 321 4.03 / 50.51 6 6
5 82.12 25 14.55 471 171 4.20 / 50.69 6 6
6 16.60 25 14.64 381 139 4.34 / 50.83 6 6
7 0.12 251 14.18 357 1271 5.61 / 52.10 6 77
Average= 4.74 (KJ/cycle)

Cycle 9 GMT 11/ 5/2014 13:38: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.40 25 14.74 482 178 0.18 / 41.28 6 6
2 2002.12 70 12.33 3282 2833 3.01 / 44.12 6 6
3 1056.76 25 13.27 1935 642 3.65 / 44.76 6 6
4 358.32 25 13.99 949 332 3.98 / 45.09 6 6
5 82.00 25 14.56 465 169 4.15 / 45.26 6 6
6 0.92 251 14.25 343 1227 5.38 / 46.49 6 32
Average= 4.65 (KJ/cycle)

Cycle 8 GMT 1/ 5/2014 13: 9: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.08 25 14.68 464 170 0.17 / 35.75 6 6
2 2002.64 70 12.37 3244 2809 2.98 / 38.56 6 6
3 1037.00 25 13.30 1915 637 3.62 / 39.20 6 6
4 339.00 25 14.03 933 327 3.94 / 39.52 6 6
5 73.32 25 14.54 465 169 4.11 / 39.69 6 6
6 16.00 25 14.64 367 134 4.25 / 39.83 6 6
7 0.04 251 14.14 361 1281 5.53 / 41.11 6 89
Average= 4.57 (KJ/cycle)

Cycle 7 GMT 21/ 4/2014 12:37: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.32 25 14.68 517 190 0.19 / 30.45 6 6
2 1990.76 70 12.40 3250 2821 3.01 / 33.27 6 6
3 1034.64 25 13.31 1862 620 3.63 / 33.89 6 6
4 322.92 25 14.09 892 314 3.94 / 34.21 6 6
5 61.00 25 14.57 447 163 4.11 / 34.37 6 6
6 0.08 251 14.20 339 1208 5.32 / 35.58 6 41
Average= 4.45 (KJ/cycle)

Cycle 6 GMT 11/ 4/2014 11:59: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.88 21 14.74 517 160 0.16 / 24.81 6 6
2 1041.24 3 14.42 1928 83 0.24 / 24.89 6 6
3 1027.64 1 14.48 2000 29 0.27 / 24.92 6 6
4 1994.88 70 12.42 3233 2811 3.08 / 27.73 6 6
5 1026.92 25 13.32 1860 619 3.70 / 28.35 6 6
6 325.16 25 14.08 895 315 4.02 / 28.66 6 6
7 73.80 25 14.56 467 170 4.19 / 28.83 6 6
8 16.24 25 14.63 386 141 4.33 / 28.98 6 6
9 0.00 251 14.14 363 1288 5.62 / 30.26 6 97
Average= 4.32 (KJ/cycle)

Cycle 5 GMT 1/ 4/2014 11:31: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.20 29 14.61 482 204 0.20 / 19.21 6 6
2 763.80 -4 14.61 482 0. 0.00 / 19.21 6 6
3 900.12 -2 14.61 482 0. 0.00 / 19.21 6 6
4 2002.04 70 12.40 3260 2830 3.03 / 22.04 6 6
5 1015.56 25 13.32 1824 607 3.64 / 22.64 6 6
6 554.24 25 13.78 1174 404 4.05 / 23.05 6 6
7 142.60 25 14.42 585 211 4.26 / 23.26 6 6
8 28.96 25 14.65 408 149 4.41 / 23.41 6 6
9 0.04 251 14.23 347 1239 5.65 / 24.65 6 73
Average= 4.11 (KJ/cycle)

Cycle 4 GMT 22/ 3/2014 11:17: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.88 23 14.68 500 169 0.17 / 14.54 6 6
2 1514.00 70 12.76 2560 2287 2.46 / 16.82 6 6
3 796.60 25 13.51 1505 508 2.96 / 17.33 6 6
4 173.44 25 14.33 647 232 3.20 / 17.56 6 6
5 92.88 25 14.50 515 187 3.38 / 17.75 6 6
6 0.12 251 14.24 350 1251 4.63 / 19.00 6 40
Average= 3.80 (KJ/cycle)

Cycle 3 GMT 21/ 3/2014 11:40: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.36 22 14.68 482 156 0.16 / 9.88 6 6
2 1028.04 1 14.42 2000 29 0.18 / 9.91 6 6
3 1501.28 70 12.74 2539 2264 2.45 / 12.17 6 6
4 780.44 25 13.51 1485 502 2.95 / 12.68 6 6
5 176.92 25 14.31 642 230 3.18 / 12.91 6 6
6 92.84 25 14.47 522 189 3.37 / 13.09 6 6
7 0.16 251 14.22 357 1274 4.64 / 14.37 6 41
Average= 3.59 (KJ/cycle)

Cycle 2 GMT 20/ 3/2014 12: 6: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.48 29 14.55 464 196 0.20 / 5.31 6 6
2 770.84 -4 14.55 464 0. 0.00 / 5.31 6 6
3 924.20 -1 14.55 464 0. 0.00 / 5.31 6 6
4 1501.00 70 12.65 2566 2272 2.47 / 7.58 6 6
5 790.44 25 13.42 1515 508 2.98 / 8.09 6 6
6 183.36 25 14.22 678 241 3.22 / 8.33 6 6
7 98.04 25 14.44 529 191 3.41 / 8.52 6 6
8 0.04 251 14.23 337 1204 4.61 / 9.73 6 39
Average= 3.24 (KJ/cycle)

Cycle 1 GMT 19/ 3/2014 12:25: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.84 29 14.68 446 190 0.19 / 1.98 7 7
2 759.72 -5 14.68 446 0. 0.00 / 1.98 7 7
3 948.88 -1 14.68 446 0. 0.00 / 1.98 7 7
4 985.72 70 12.97 1807 1641 1.83 / 3.62 7 6
5 120.44 24 14.36 549 189 2.02 / 3.81 6 6
6 61.96 25 14.49 446 162 2.18 / 3.97 6 6
7 0.16 251 14.26 320 1145 3.33 / 5.11 6 56
Average= 2.56 (KJ/cycle)

Cycle 0 GMT 19/ 3/2014 0:20: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 135.36 70 14.37 470 473 0.47 / 0.47 174 7
2 123.16 25 14.64 460 168 0.64 / 0.64 7 7
3 68.84 25 14.77 381 141 0.78 / 0.78 7 7
4 0.20 251 14.61 274 1005 1.79 / 1.79 7 32
Average= 1.79 (KJ/cycle)