SIO Argo Site:
Pump Diagnostics Page   



Serial= 8131 WMO= 5904332

Return

←PreviousNext→

Cycle 216 GMT 16/11/2018 3:50: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.36 41 10.57 480 208 0.21 / 1046.46 6 6
2 1005.68 50 7.39 1914 707 0.92 / 1047.16 6 6
3 904.00 31 7.85 1751 426 1.34 / 1047.59 6 6
4 778.24 31 8.23 1587 405 1.75 / 1047.99 6 6
5 211.44 31 10.06 661 206 1.95 / 1048.20 6 6
6 13.92 30 10.72 310 100 2.05 / 1048.30 6 6
7 0.00 181 10.78 289 564 2.62 / 1048.86 6 15
Average= 4.83 (KJ/cycle)

Cycle 215 GMT 6/11/2018 10:28: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.52 41 10.50 500 215 0.22 / 1043.93 6 6
2 997.48 50 7.45 1916 714 0.93 / 1044.65 6 6
3 887.92 31 7.93 1759 432 1.36 / 1045.08 6 6
4 767.16 31 8.39 1557 405 1.77 / 1045.48 6 6
5 187.92 30 10.18 622 190 1.96 / 1045.67 6 6
6 0.20 181 10.78 294 574 2.53 / 1046.25 6 15
Average= 4.84 (KJ/cycle)

Cycle 214 GMT 27/10/2018 17:11: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.08 41 10.57 500 217 0.22 / 1041.48 6 6
2 1010.80 50 7.64 1925 735 0.95 / 1042.22 6 6
3 888.80 31 8.02 1751 435 1.39 / 1042.65 6 6
4 618.52 30 8.87 1327 353 1.74 / 1043.01 6 6
5 82.76 31 10.56 437 143 1.88 / 1043.15 6 6
6 0.04 181 10.80 291 569 2.45 / 1043.72 6 13
Average= 4.85 (KJ/cycle)

Cycle 213 GMT 17/10/2018 23:53: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.12 44 10.63 461 216 0.22 / 1036.71 6 6
2 915.12 -1 10.63 461 0. 0.00 / 1036.71 6 6
3 943.28 -1 10.63 461 0. 0.00 / 1036.71 6 6
4 1196.16 11 7.36 2222 180 0.40 / 1036.89 6 6
5 1285.48 120 6.98 2373 1988 2.38 / 1038.87 6 6
6 1282.56 51 6.49 2360 781 3.16 / 1039.65 6 6
7 1006.28 31 7.75 1940 466 3.63 / 1040.12 6 6
8 726.64 31 8.51 1522 402 4.03 / 1040.52 6 6
9 54.52 31 10.59 409 134 4.17 / 1040.66 6 6
10 0.08 181 10.77 313 610 4.78 / 1041.27 6 11
Average= 4.87 (KJ/cycle)

Cycle 212 GMT 16/10/2018 21:41: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.60 43 10.63 480 219 0.22 / 1034.26 6 6
2 952.72 -1 10.63 480 0. 0.00 / 1034.26 6 6
3 993.12 50 7.72 1906 736 0.96 / 1034.99 6 6
4 878.12 31 8.20 1732 440 1.40 / 1035.43 6 6
5 615.76 30 8.86 1342 357 1.75 / 1035.79 6 6
6 75.52 30 10.58 424 135 1.89 / 1035.92 6 6
7 0.08 181 10.81 289 565 2.45 / 1036.49 6 16
Average= 4.87 (KJ/cycle)

Cycle 211 GMT 7/10/2018 4:25: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.20 43 10.57 500 227 0.23 / 1031.81 6 6
2 961.20 -1 10.57 500 0. 0.00 / 1031.81 6 6
3 993.24 50 7.79 1916 746 0.97 / 1032.55 6 6
4 881.28 30 8.34 1709 428 1.40 / 1032.98 6 6
5 607.16 30 9.01 1316 356 1.76 / 1033.34 6 6
6 82.00 30 10.57 437 139 1.90 / 1033.47 6 6
7 0.04 180 10.83 289 563 2.46 / 1034.04 6 14
Average= 4.88 (KJ/cycle)

Cycle 210 GMT 27/ 9/2018 11: 7: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.44 38 10.57 500 201 0.20 / 1029.23 6 6
2 1003.44 4 8.32 1980 66 0.27 / 1029.30 6 6
3 1007.72 50 7.89 1936 764 1.03 / 1030.06 6 6
4 893.44 30 8.38 1736 436 1.47 / 1030.50 6 6
5 624.20 30 9.03 1345 364 1.83 / 1030.86 6 6
6 88.68 31 10.63 445 147 1.98 / 1031.01 6 6
7 0.12 181 10.83 290 568 2.55 / 1031.58 6 9
Average= 4.89 (KJ/cycle)

Cycle 209 GMT 17/ 9/2018 17:54: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.68 36 10.44 480 180 0.18 / 1023.09 6 6
2 1035.04 6 7.75 2000 93 0.27 / 1023.18 6 6
3 1070.64 2 7.50 2076 31 0.30 / 1023.21 6 6
4 1042.60 1 7.88 2019 16 0.32 / 1023.23 6 6
5 1143.48 11 7.34 2149 174 0.49 / 1023.40 6 6
6 1435.32 120 5.70 2619 1791 2.29 / 1025.20 6 6
7 1433.96 51 4.80 2382 583 2.87 / 1025.78 6 7
8 1384.44 31 6.48 2498 502 3.37 / 1026.28 6 6
9 1311.00 30 6.82 2427 497 3.87 / 1026.78 6 6
10 1214.20 31 7.34 2231 508 4.37 / 1027.28 6 6
11 1097.80 31 7.54 2116 495 4.87 / 1027.78 6 6
12 706.84 31 8.65 1494 401 5.27 / 1028.18 6 6
13 290.20 31 9.90 813 250 5.52 / 1028.43 6 6
14 0.16 181 10.79 309 603 6.12 / 1029.03 6 11
Average= 4.90 (KJ/cycle)

Cycle 208 GMT 16/ 9/2018 14:36: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.44 32 10.94 442 155 0.15 / 1020.42 6 6
2 1007.52 6 8.50 1961 100 0.25 / 1020.52 6 6
3 1036.32 4 8.07 2038 66 0.32 / 1020.58 6 6
4 1038.00 1 8.69 1980 17 0.34 / 1020.60 6 6
5 1022.12 1 8.44 1961 17 0.35 / 1020.61 6 6
6 1024.44 50 7.50 1940 727 1.08 / 1021.34 6 6
7 919.36 30 7.84 1784 420 1.50 / 1021.76 6 6
8 789.00 30 8.11 1592 387 1.89 / 1022.15 6 6
9 222.60 30 10.02 676 203 2.09 / 1022.35 6 6
10 0.04 180 10.76 288 558 2.65 / 1022.91 6 13
Average= 4.89 (KJ/cycle)

Cycle 207 GMT 6/ 9/2018 21:21: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.16 38 11.07 500 210 0.21 / 1017.86 6 6
2 1019.28 1 8.88 2076 18 0.23 / 1017.88 6 6
3 1011.52 50 5.67 1898 538 0.77 / 1018.42 6 6
4 918.64 30 7.69 1783 411 1.18 / 1018.83 6 6
5 797.56 30 8.19 1614 397 1.57 / 1019.22 6 6
6 533.28 30 9.19 1199 331 1.91 / 1019.56 6 6
7 41.64 30 10.96 371 122 2.03 / 1019.68 6 6
8 0.12 181 11.03 292 583 2.61 / 1020.26 6 11
Average= 4.91 (KJ/cycle)

Cycle 206 GMT 28/ 8/2018 3:54: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.44 31 11.88 500 184 0.18 / 1015.10 6 6
2 1011.52 5 10.57 1980 105 0.29 / 1015.20 6 6
3 1052.20 1 10.44 2038 21 0.31 / 1015.22 6 6
4 1030.04 1 10.38 2057 21 0.33 / 1015.24 6 6
5 1024.24 50 7.26 1937 703 1.03 / 1015.95 6 6
6 922.12 31 8.46 1812 475 1.51 / 1016.42 6 6
7 662.48 30 9.28 1409 392 1.90 / 1016.81 6 6
8 237.84 30 10.59 720 229 2.13 / 1017.04 6 6
9 0.08 181 11.29 297 607 2.74 / 1017.65 6 12
Average= 4.92 (KJ/cycle)

Cycle 205 GMT 18/ 8/2018 10:30: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.40 31 12.31 480 183 0.18 / 1010.47 6 6
2 1027.20 4 10.94 2019 88 0.27 / 1010.56 6 6
3 1121.00 12 10.22 2191 269 0.54 / 1010.83 6 6
4 1252.60 120 8.33 2311 2310 2.85 / 1013.14 6 6
5 1246.00 51 6.72 2260 775 3.62 / 1013.91 6 6
6 347.76 30 10.94 937 308 3.93 / 1014.22 6 6
7 0.08 181 11.75 326 693 4.63 / 1014.91 6 11
Average= 4.93 (KJ/cycle)

Cycle 204 GMT 17/ 8/2018 8:28: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.80 31 13.00 519 209 0.21 / 1007.49 6 6
2 1034.60 1 10.82 2038 22 0.23 / 1007.52 6 6
3 1025.12 1 10.38 2038 21 0.25 / 1007.54 6 6
4 1018.44 50 5.03 1891 476 0.73 / 1008.01 6 7
5 957.08 30 8.33 1866 466 1.19 / 1008.48 6 6
6 860.56 30 8.96 1712 460 1.65 / 1008.94 6 6
7 730.44 31 9.56 1528 453 2.11 / 1009.39 6 6
8 146.08 30 12.03 572 206 2.31 / 1009.60 6 6
9 0.08 181 12.31 309 688 3.00 / 1010.29 6 17
Average= 4.93 (KJ/cycle)

Cycle 203 GMT 7/ 8/2018 14:59: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.32 31 13.56 500 210 0.21 / 1004.44 6 6
2 995.00 50 4.61 1312 302 0.51 / 1004.74 6 7
3 995.88 30 6.57 1879 370 0.88 / 1005.11 6 7
4 925.28 30 7.78 1797 419 1.30 / 1005.53 6 6
5 826.84 30 8.94 1675 449 1.75 / 1005.98 6 6
6 566.16 30 10.63 1276 407 2.16 / 1006.39 6 6
7 51.72 30 13.20 414 164 2.32 / 1006.55 6 6
8 0.04 180 12.95 314 732 3.05 / 1007.28 6 21
Average= 4.94 (KJ/cycle)

Cycle 202 GMT 28/ 7/2018 20:52: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.68 31 13.93 519 224 0.22 / 1001.35 6 6
2 990.24 50 4.79 1791 429 0.65 / 1001.78 6 7
3 954.68 31 8.60 1869 498 1.15 / 1002.28 6 6
4 858.16 31 9.46 1730 507 1.66 / 1002.79 6 6
5 731.80 31 10.30 1538 491 2.15 / 1003.28 6 6
6 64.68 31 13.53 445 187 2.34 / 1003.47 6 6
7 0.00 180 13.39 317 764 3.10 / 1004.23 6 19
Average= 4.95 (KJ/cycle)

Cycle 201 GMT 19/ 7/2018 3:15: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.00 31 13.81 500 214 0.21 / 994.84 6 6
2 1105.16 12 10.15 2130 259 0.47 / 995.10 6 6
3 1656.52 120 5.80 2714 1889 2.36 / 996.99 6 6
4 1652.88 51 7.02 2850 1020 3.38 / 998.01 6 6
5 1543.76 30 9.24 2767 767 4.15 / 998.77 6 6
6 1414.60 30 9.54 2608 746 4.90 / 999.52 6 6
7 702.96 30 11.61 1530 533 5.43 / 1000.05 6 6
8 110.16 30 13.58 552 225 5.65 / 1000.28 6 6
9 0.12 180 13.60 348 852 6.51 / 1001.13 6 22
Average= 4.96 (KJ/cycle)

Cycle 200 GMT 18/ 7/2018 0: 9: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.44 31 13.93 519 224 0.22 / 991.72 6 6
2 999.52 50 4.62 1375 318 0.54 / 992.04 6 7
3 999.76 30 8.83 1916 508 1.05 / 992.55 6 6
4 902.52 31 9.95 1797 554 1.60 / 993.10 6 6
5 636.88 31 11.52 1411 504 2.11 / 993.60 6 6
6 91.64 30 13.80 498 206 2.31 / 993.81 6 6
7 0.12 181 13.91 323 813 3.13 / 994.62 6 23
Average= 4.95 (KJ/cycle)

Cycle 199 GMT 8/ 7/2018 6:11: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.92 29 13.68 557 221 0.22 / 988.48 6 6
2 1046.32 1 10.94 2057 23 0.24 / 988.50 6 6
3 1031.56 1 10.38 2057 21 0.26 / 988.52 6 6
4 1020.12 50 4.65 1472 342 0.61 / 988.87 6 7
5 1012.76 30 9.28 1951 543 1.15 / 989.41 6 6
6 924.52 30 10.17 1827 557 1.71 / 989.97 6 6
7 655.64 31 11.62 1438 518 2.23 / 990.48 6 6
8 39.32 31 14.00 398 173 2.40 / 990.66 6 6
9 -0.08 181 13.93 333 840 3.24 / 991.50 6 18
Average= 4.96 (KJ/cycle)

Cycle 198 GMT 28/ 6/2018 12: 9: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.16 31 14.06 519 226 0.23 / 985.53 6 6
2 953.28 -1 14.06 519 0. 0.00 / 985.53 6 6
3 1009.00 50 5.10 1832 467 0.69 / 985.99 6 6
4 931.12 30 10.28 1856 572 1.27 / 986.56 6 6
5 805.76 31 11.02 1664 568 1.83 / 987.13 6 6
6 220.64 30 13.44 715 288 2.12 / 987.42 6 6
7 0.16 181 13.98 331 838 2.96 / 988.26 6 18
Average= 4.97 (KJ/cycle)

Cycle 197 GMT 18/ 6/2018 18:53: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.44 30 13.93 538 225 0.22 / 979.69 6 6
2 1116.96 12 10.57 2168 275 0.50 / 979.96 6 6
3 1520.36 120 7.30 2742 2402 2.90 / 982.36 6 6
4 1512.92 51 8.91 2769 1258 4.16 / 983.62 6 6
5 641.28 31 12.72 1442 569 4.73 / 984.19 6 6
6 76.16 31 13.99 496 215 4.94 / 984.41 6 7
7 0.00 181 14.06 351 893 5.84 / 985.30 6 24
Average= 4.98 (KJ/cycle)

Cycle 196 GMT 17/ 6/2018 16:14: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.08 31 14.06 538 234 0.23 / 976.60 6 6
2 990.04 50 4.66 1499 349 0.58 / 976.95 6 7
3 994.24 31 10.30 1951 623 1.21 / 977.57 6 6
4 893.40 31 10.90 1792 606 1.81 / 978.18 6 6
5 471.80 31 12.62 1142 447 2.26 / 978.62 6 6
6 0.08 181 14.06 330 840 3.10 / 979.46 6 23
Average= 4.97 (KJ/cycle)

Cycle 195 GMT 7/ 6/2018 22:16: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.24 31 14.06 519 226 0.23 / 973.25 6 6
2 1002.32 50 4.68 1620 379 0.61 / 973.63 6 7
3 999.92 30 10.37 1962 610 1.22 / 974.24 6 6
4 902.36 30 10.93 1821 597 1.81 / 974.83 6 6
5 629.64 30 12.10 1396 507 2.32 / 975.34 6 6
6 30.56 31 14.07 385 168 2.49 / 975.51 6 7
7 0.08 181 14.09 335 854 3.34 / 976.36 6 25
Average= 4.98 (KJ/cycle)

Cycle 194 GMT 29/ 5/2018 4:22: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.72 31 14.06 538 234 0.23 / 970.31 6 6
2 998.60 50 6.07 1860 565 0.80 / 970.87 6 6
3 912.24 31 11.22 1842 641 1.44 / 971.52 6 6
4 516.96 30 12.66 1219 463 1.90 / 971.98 6 6
5 39.52 31 14.05 403 176 2.08 / 972.15 6 6
6 0.08 181 14.13 339 867 2.95 / 973.02 6 23
Average= 4.99 (KJ/cycle)

Cycle 193 GMT 19/ 5/2018 11: 3: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.24 30 14.06 480 202 0.20 / 965.10 6 6
2 1116.00 12 10.47 2149 270 0.47 / 965.37 6 6
3 1244.36 120 8.91 2320 2481 2.95 / 967.85 6 6
4 1236.28 51 9.41 2326 1116 4.07 / 968.96 6 6
5 43.76 30 14.06 435 183 4.25 / 969.15 6 6
6 0.56 181 14.08 364 928 5.18 / 970.08 6 27
Average= 5.00 (KJ/cycle)

Cycle 192 GMT 18/ 5/2018 9:22: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.40 31 14.12 500 219 0.22 / 962.10 6 6
2 995.00 50 4.67 1533 358 0.58 / 962.45 6 7
3 989.32 30 10.49 1945 612 1.19 / 963.07 6 6
4 887.52 30 11.06 1828 607 1.80 / 963.67 6 6
5 349.92 30 13.16 949 375 2.17 / 964.05 6 6
6 0.16 181 14.12 332 848 3.02 / 964.90 6 28
Average= 5.00 (KJ/cycle)

Cycle 191 GMT 8/ 5/2018 15:24: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.76 31 14.12 519 227 0.23 / 958.94 6 6
2 991.56 50 4.71 1682 396 0.62 / 959.33 6 7
3 985.76 30 10.24 1932 594 1.22 / 959.93 6 6
4 886.68 30 10.99 1796 592 1.81 / 960.52 6 6
5 350.60 30 13.25 943 375 2.18 / 960.90 6 6
6 17.20 30 14.09 363 153 2.34 / 961.05 6 7
7 0.20 180 14.20 324 828 3.17 / 961.88 6 19
Average= 5.01 (KJ/cycle)

Cycle 190 GMT 28/ 4/2018 21:41: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.68 31 14.12 538 235 0.24 / 955.95 6 6
2 982.40 50 6.70 1900 636 0.87 / 956.59 6 6
3 891.88 31 11.64 1802 650 1.52 / 957.24 6 6
4 472.08 30 12.95 1151 447 1.97 / 957.69 6 6
5 28.72 31 14.10 385 168 2.14 / 957.85 6 7
6 0.04 181 14.18 334 857 2.99 / 958.71 6 23
Average= 5.02 (KJ/cycle)

Cycle 189 GMT 19/ 4/2018 4:22: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.28 29 14.06 500 204 0.20 / 950.29 6 6
2 1000.40 4 11.82 1980 94 0.30 / 950.38 6 6
3 951.52 -1 11.82 1980 0. 0.09 / 950.38 6 6
4 966.48 -1 11.82 1980 0. 0.09 / 950.38 6 6
5 1106.48 12 10.76 2161 279 0.58 / 950.66 6 6
6 1427.32 120 8.68 2594 2702 3.28 / 953.36 6 6
7 1420.64 51 9.32 2614 1242 4.52 / 954.60 6 6
8 56.48 31 14.09 456 199 4.72 / 954.80 6 6
9 0.20 181 14.16 357 915 5.64 / 955.72 6 18
Average= 5.03 (KJ/cycle)

Cycle 188 GMT 18/ 4/2018 2:12: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.16 29 14.06 500 204 0.20 / 946.96 6 6
2 1029.92 1 11.13 2019 22 0.23 / 946.98 6 6
3 1020.48 1 10.38 2019 21 0.25 / 947.00 6 6
4 1029.36 50 4.67 1546 361 0.61 / 947.37 6 7
5 1020.80 31 10.85 1986 668 1.28 / 948.03 6 6
6 910.92 31 11.45 1831 650 1.93 / 948.68 6 6
7 359.24 31 13.28 965 397 2.32 / 949.08 6 7
8 12.64 30 14.11 355 150 2.47 / 949.23 6 7
9 0.00 181 14.15 332 850 3.32 / 950.08 6 27
Average= 5.03 (KJ/cycle)

Cycle 187 GMT 8/ 4/2018 8:15: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.80 29 14.06 500 204 0.20 / 943.52 6 6
2 1033.56 1 11.25 2019 23 0.23 / 943.54 6 6
3 1024.52 1 10.82 2076 22 0.25 / 943.56 6 6
4 1010.80 50 4.69 1644 386 0.63 / 943.95 6 7
5 1011.64 30 10.26 2001 616 1.25 / 944.56 6 6
6 906.04 31 11.21 1837 638 1.89 / 945.20 6 6
7 612.08 30 12.40 1392 518 2.41 / 945.72 6 6
8 50.12 31 13.99 432 187 2.59 / 945.91 6 7
9 0.12 181 14.13 332 849 3.44 / 946.76 6 23
Average= 5.04 (KJ/cycle)

Cycle 186 GMT 29/ 3/2018 14:45: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.76 31 13.93 538 232 0.23 / 940.59 6 6
2 953.00 -1 13.93 538 0. 0.00 / 940.59 6 6
3 984.88 50 6.60 1829 604 0.84 / 941.19 6 6
4 893.08 30 11.68 1824 639 1.48 / 941.83 6 6
5 486.52 31 12.91 1187 475 1.95 / 942.30 6 7
6 29.24 31 14.09 384 168 2.12 / 942.47 6 7
7 0.00 181 14.16 329 843 2.96 / 943.31 6 25
Average= 5.04 (KJ/cycle)

Cycle 185 GMT 19/ 3/2018 21:31: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.36 31 14.00 519 225 0.23 / 935.16 6 6
2 958.28 -1 14.00 519 0. 0.00 / 935.16 6 6
3 1100.28 12 10.64 2138 273 0.50 / 935.43 6 6
4 1402.88 120 8.23 2562 2530 3.03 / 937.96 6 6
5 1395.24 51 9.32 2592 1232 4.26 / 939.19 6 6
6 132.72 31 13.88 597 257 4.52 / 939.45 6 7
7 0.12 181 14.15 353 904 5.42 / 940.35 6 23
Average= 5.06 (KJ/cycle)

Cycle 184 GMT 18/ 3/2018 19:15: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.96 31 14.00 538 233 0.23 / 931.84 6 6
2 966.92 -1 14.00 538 0. 0.00 / 931.84 6 6
3 1010.20 50 4.65 1466 341 0.57 / 932.18 6 7
4 1002.92 30 10.52 1985 626 1.20 / 932.80 6 6
5 914.04 30 11.31 1853 629 1.83 / 933.43 6 6
6 500.64 31 12.82 1204 478 2.31 / 933.91 6 6
7 30.24 31 14.05 387 169 2.48 / 934.08 6 7
8 0.04 181 14.12 334 854 3.33 / 934.93 6 26
Average= 5.05 (KJ/cycle)

Cycle 183 GMT 9/ 3/2018 1:20: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.28 31 14.00 538 233 0.23 / 928.54 6 6
2 981.56 50 4.67 1559 364 0.60 / 928.90 6 7
3 970.08 31 10.13 1913 601 1.20 / 929.51 6 6
4 884.12 30 11.11 1807 602 1.80 / 930.11 6 6
5 463.32 31 12.91 1142 457 2.26 / 930.56 6 6
6 52.56 31 13.98 434 188 2.45 / 930.75 6 7
7 0.16 181 14.13 332 849 3.29 / 931.60 6 26
Average= 5.06 (KJ/cycle)

Cycle 182 GMT 27/ 2/2018 7:49: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.20 31 14.00 538 233 0.23 / 925.59 6 6
2 983.88 50 6.47 1829 592 0.83 / 926.18 6 6
3 896.80 30 11.71 1816 638 1.46 / 926.82 6 6
4 486.88 31 13.02 1177 475 1.94 / 927.29 6 6
5 28.32 30 14.08 380 161 2.10 / 927.45 6 7
6 0.08 181 14.16 334 856 2.95 / 928.31 6 24
Average= 5.07 (KJ/cycle)

Cycle 181 GMT 17/ 2/2018 14:33: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.00 31 14.06 519 226 0.23 / 919.98 6 6
2 1103.80 12 10.58 2130 270 0.50 / 920.25 6 6
3 1517.00 120 7.59 2741 2497 2.99 / 922.75 6 6
4 1509.72 51 9.25 2789 1316 4.31 / 924.06 6 6
5 338.80 30 13.53 948 385 4.69 / 924.45 6 6
6 0.04 181 14.19 352 904 5.60 / 925.35 6 25
Average= 5.08 (KJ/cycle)

Cycle 180 GMT 16/ 2/2018 11:52: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.60 30 13.93 538 225 0.22 / 916.65 6 6
2 1034.76 1 11.00 2076 23 0.25 / 916.68 6 6
3 1020.76 1 10.19 2038 21 0.27 / 916.70 6 6
4 1016.36 50 4.63 1407 326 0.59 / 917.02 6 7
5 1013.96 31 10.63 1990 656 1.25 / 917.68 6 6
6 916.00 31 11.52 1866 666 1.92 / 918.35 6 6
7 364.60 30 13.33 977 391 2.31 / 918.74 6 6
8 29.88 31 14.06 385 168 2.47 / 918.90 6 7
9 0.08 181 14.15 332 850 3.33 / 919.75 6 24
Average= 5.08 (KJ/cycle)

Cycle 179 GMT 6/ 2/2018 17:52: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.72 31 14.06 519 226 0.23 / 913.37 6 6
2 996.64 50 4.66 1548 361 0.59 / 913.73 6 7
3 1004.68 30 10.10 1969 597 1.18 / 914.33 6 6
4 893.92 30 11.35 1815 618 1.80 / 914.94 6 6
5 480.48 30 12.98 1177 458 2.26 / 915.40 6 7
6 25.72 30 14.03 379 160 2.42 / 915.56 6 7
7 0.12 181 14.14 339 868 3.29 / 916.43 6 22
Average= 5.09 (KJ/cycle)

Cycle 178 GMT 28/ 1/2018 0:19: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.40 31 14.06 538 234 0.23 / 910.28 6 6
2 999.68 50 6.08 1876 570 0.80 / 910.85 6 6
3 912.80 31 11.66 1847 668 1.47 / 911.51 6 6
4 792.68 30 12.08 1674 607 2.08 / 912.12 6 6
5 29.20 31 14.06 379 165 2.24 / 912.29 6 6
6 0.04 181 14.16 334 856 3.10 / 913.14 6 19
Average= 5.10 (KJ/cycle)

Cycle 177 GMT 18/ 1/2018 7: 1: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.08 30 14.06 519 219 0.22 / 904.97 6 6
2 1025.64 1 10.38 2076 22 0.24 / 904.99 6 6
3 1127.12 11 10.35 2191 249 0.49 / 905.24 6 6
4 1276.00 120 8.75 2382 2501 2.99 / 907.74 6 6
5 1269.52 51 9.51 2399 1164 4.15 / 908.90 6 6
6 99.36 30 13.93 533 223 4.38 / 909.12 6 7
7 0.68 180 14.13 361 918 5.30 / 910.04 6 19
Average= 5.11 (KJ/cycle)

Cycle 176 GMT 17/ 1/2018 5:18: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.48 31 14.00 538 233 0.23 / 901.69 6 6
2 967.84 -1 14.00 538 0. 0.00 / 901.69 6 6
3 1011.04 50 4.62 1402 324 0.56 / 902.02 6 7
4 1005.88 31 10.44 1961 635 1.19 / 902.65 6 6
5 894.08 30 11.58 1812 629 1.82 / 903.28 6 6
6 477.00 30 13.04 1159 453 2.27 / 903.73 6 7
7 21.24 31 14.09 366 160 2.43 / 903.89 6 7
8 0.00 181 14.14 333 852 3.29 / 904.75 6 22
Average= 5.11 (KJ/cycle)

Cycle 175 GMT 7/ 1/2018 11:27: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.56 29 13.75 557 222 0.22 / 898.19 6 6
2 1041.24 1 11.07 2038 23 0.24 / 898.21 6 6
3 1031.84 1 10.82 2057 22 0.27 / 898.23 6 6
4 1023.48 50 4.67 1551 362 0.63 / 898.59 6 7
5 1002.80 30 10.48 1994 627 1.26 / 899.22 6 6
6 905.52 30 11.47 1844 635 1.89 / 899.85 6 6
7 629.92 31 12.61 1421 555 2.45 / 900.41 6 6
8 25.16 31 14.03 387 168 2.61 / 900.58 6 7
9 0.08 181 14.12 345 882 3.50 / 901.46 6 24
Average= 5.12 (KJ/cycle)

Cycle 174 GMT 28/12/2017 17:55: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.32 31 13.75 557 237 0.24 / 895.11 6 6
2 966.20 -1 13.75 557 0. 0.00 / 895.11 6 6
3 1027.20 50 6.26 1886 590 0.83 / 895.71 6 6
4 941.20 30 11.68 1895 664 1.49 / 896.37 6 6
5 676.68 30 12.58 1493 563 2.06 / 896.93 6 6
6 17.24 30 14.06 368 155 2.21 / 897.09 6 7
7 0.04 181 14.11 343 876 3.09 / 897.96 6 29
Average= 5.13 (KJ/cycle)

Cycle 173 GMT 19/12/2017 0:34: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.32 30 14.00 519 218 0.22 / 890.50 6 6
2 1076.60 120 9.10 2071 2262 2.48 / 892.76 6 6
3 1072.36 50 9.64 2081 1003 3.48 / 893.76 6 6
4 34.20 30 13.97 435 182 3.66 / 893.94 6 7
5 0.12 180 14.04 370 935 4.60 / 894.88 6 25
Average= 5.14 (KJ/cycle)

Cycle 172 GMT 17/12/2017 23:14: 3

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.08 31 13.81 538 230 0.23 / 887.11 6 6
2 993.56 50 4.67 1571 367 0.60 / 887.47 6 7
3 991.68 30 10.46 1970 618 1.22 / 888.09 6 6
4 871.56 30 11.52 1802 623 1.84 / 888.72 6 6
5 597.08 30 12.62 1356 513 2.35 / 889.23 6 6
6 12.92 31 13.95 379 164 2.52 / 889.39 6 7
7 0.12 181 14.05 348 885 3.40 / 890.28 6 28
Average= 5.15 (KJ/cycle)

Cycle 171 GMT 8/12/2017 5:49: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.76 30 13.75 557 230 0.23 / 883.94 6 6
2 1018.68 80 5.06 1831 741 0.97 / 884.68 6 6
3 903.36 46 11.37 1820 952 1.92 / 885.63 6 6
4 132.44 46 13.82 577 367 2.29 / 886.00 6 7
5 -0.04 181 14.07 346 881 3.17 / 886.88 6 24
Average= 5.16 (KJ/cycle)

Cycle 170 GMT 28/11/2017 12:20: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.12 30 13.75 576 238 0.24 / 880.79 6 6
2 996.32 80 7.13 1875 1069 1.31 / 881.86 6 6
3 836.56 46 11.95 1720 945 2.25 / 882.81 6 6
4 0.16 181 14.07 353 899 3.15 / 883.71 6 23
Average= 5.17 (KJ/cycle)

Cycle 169 GMT 18/11/2017 19:12: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.16 30 13.68 557 229 0.23 / 874.81 6 6
2 1101.52 15 10.52 2114 334 0.56 / 875.14 6 6
3 1407.48 120 8.22 2571 2536 3.10 / 877.68 6 6
4 1400.12 80 9.25 2576 1906 5.00 / 879.59 6 6
5 0.00 181 14.01 382 969 5.97 / 880.55 6 25
Average= 5.18 (KJ/cycle)

Cycle 168 GMT 17/11/2017 17:22: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.52 31 13.87 538 231 0.23 / 871.39 6 6
2 991.76 80 4.65 1573 585 0.82 / 871.97 6 7
3 988.24 45 10.43 1951 916 1.73 / 872.89 6 6
4 629.52 46 12.45 1393 798 2.53 / 873.69 6 6
5 0.00 181 14.00 353 895 3.42 / 874.58 6 27
Average= 5.18 (KJ/cycle)

Cycle 167 GMT 7/11/2017 23:14: 3

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.92 30 14.00 519 218 0.22 / 867.85 6 6
2 1001.92 80 4.72 1804 681 0.90 / 868.53 6 6
3 979.68 46 10.87 1935 968 1.87 / 869.50 6 6
4 625.52 45 12.43 1394 780 2.65 / 870.28 6 6
5 0.00 181 14.05 345 877 3.52 / 871.16 6 19
Average= 5.19 (KJ/cycle)

Cycle 166 GMT 29/10/2017 5:35: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.16 30 13.93 519 217 0.22 / 864.77 6 6
2 1010.84 80 6.82 1896 1034 1.25 / 865.80 6 6
3 828.60 46 11.92 1720 943 2.19 / 866.75 6 6
4 0.04 181 14.09 348 888 3.08 / 867.63 6 24
Average= 5.20 (KJ/cycle)

Cycle 165 GMT 19/10/2017 12:25: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.96 29 13.68 538 213 0.21 / 858.94 6 6
2 1038.20 1 10.69 2076 22 0.24 / 858.97 6 6
3 1133.48 15 10.29 2188 338 0.57 / 859.30 6 6
4 1372.64 120 8.13 2508 2447 3.02 / 861.75 6 6
5 1365.04 80 9.11 2530 1844 4.86 / 863.59 6 6
6 0.12 180 14.02 379 956 5.82 / 864.55 6 20
Average= 5.21 (KJ/cycle)

Cycle 164 GMT 18/10/2017 10:41: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.28 31 13.75 557 237 0.24 / 855.58 6 6
2 989.24 80 4.64 1527 567 0.80 / 856.15 6 7
3 987.88 46 10.05 1936 895 1.70 / 857.04 6 6
4 637.48 46 12.32 1424 807 2.51 / 857.85 6 6
5 0.12 181 14.02 347 881 3.39 / 858.73 6 27
Average= 5.20 (KJ/cycle)

Cycle 163 GMT 8/10/2017 16:30:58

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.40 30 13.87 538 224 0.22 / 852.04 6 6
2 1009.40 80 4.70 1743 655 0.88 / 852.69 6 7
3 1006.12 46 10.52 1965 951 1.83 / 853.64 6 6
4 651.76 46 12.28 1443 815 2.65 / 854.46 6 6
5 0.04 181 14.02 349 886 3.53 / 855.34 6 21
Average= 5.22 (KJ/cycle)

Cycle 162 GMT 28/ 9/2017 22:50: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.96 29 13.87 557 224 0.22 / 849.00 6 6
2 1015.88 80 6.58 1877 988 1.21 / 849.99 6 6
3 840.20 46 11.84 1728 941 2.15 / 850.93 6 6
4 0.04 181 14.05 348 885 3.04 / 851.81 6 21
Average= 5.23 (KJ/cycle)

Cycle 161 GMT 19/ 9/2017 5:41: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.12 31 13.62 538 227 0.23 / 843.11 6 6
2 966.12 -1 13.62 538 0. 0.00 / 843.11 6 6
3 1110.36 15 10.12 2127 323 0.55 / 843.43 6 6
4 1378.80 120 7.78 2532 2364 2.91 / 845.80 6 6
5 1371.64 80 8.87 2547 1807 4.72 / 847.60 6 6
6 4.52 45 14.02 374 236 4.96 / 847.84 6 10
7 0.04 180 14.02 371 936 5.89 / 848.77 6 29
Average= 5.24 (KJ/cycle)

Cycle 160 GMT 18/ 9/2017 3:50: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.12 30 13.81 557 231 0.23 / 839.71 6 6
2 1020.04 1 9.19 2000 18 0.25 / 839.73 6 6
3 1015.56 80 4.64 1495 555 0.80 / 840.28 6 7
4 1012.28 46 9.93 1987 908 1.71 / 841.19 6 6
5 653.56 46 12.29 1443 816 2.53 / 842.00 6 6
6 0.28 181 14.02 346 878 3.41 / 842.88 6 26
Average= 5.24 (KJ/cycle)

Cycle 159 GMT 8/ 9/2017 9:37: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.52 31 13.68 557 236 0.24 / 836.28 6 6
2 962.32 -1 13.68 557 0. 0.00 / 836.28 6 6
3 998.40 80 4.65 1623 604 0.84 / 836.89 6 7
4 1005.24 46 9.88 1961 891 1.73 / 837.78 6 6
5 655.44 46 12.18 1439 806 2.54 / 838.58 6 6
6 0.52 181 13.96 353 892 3.43 / 839.48 6 31
Average= 5.25 (KJ/cycle)

Cycle 158 GMT 29/ 8/2017 15:51: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.84 31 13.93 538 232 0.23 / 833.47 6 6
2 971.64 80 6.23 1808 901 1.13 / 834.37 6 6
3 650.56 45 12.19 1435 787 1.92 / 835.16 6 6
4 0.24 181 13.98 350 886 2.81 / 836.05 6 26
Average= 5.26 (KJ/cycle)

Cycle 157 GMT 19/ 8/2017 22:31: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.64 31 13.75 557 237 0.24 / 826.72 6 6
2 1103.64 15 9.73 2137 312 0.55 / 827.04 6 6
3 1625.36 120 5.64 2939 1989 2.54 / 829.02 6 6
4 1622.08 80 7.75 2930 1817 4.36 / 830.84 6 6
5 1066.44 45 11.74 2128 1124 5.48 / 831.97 6 6
6 107.48 45 13.81 559 347 5.83 / 832.31 6 7
7 0.24 181 14.04 365 928 6.75 / 833.24 6 30
Average= 5.27 (KJ/cycle)

Cycle 156 GMT 18/ 8/2017 19:18: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.60 31 13.56 538 226 0.23 / 823.41 6 6
2 967.00 -1 13.56 538 0. 0.00 / 823.41 6 6
3 1007.52 80 4.61 1412 521 0.75 / 823.93 6 7
4 995.56 46 9.18 1931 815 1.56 / 824.75 6 6
5 821.20 46 11.36 1709 893 2.46 / 825.64 6 6
6 -0.08 181 14.01 333 844 3.30 / 826.49 6 21
Average= 5.26 (KJ/cycle)

Cycle 155 GMT 9/ 8/2017 1: 6: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.56 31 13.87 538 231 0.23 / 820.06 6 6
2 978.60 80 4.65 1624 604 0.84 / 820.66 6 7
3 982.12 46 9.80 1922 866 1.70 / 821.53 6 6
4 632.36 46 12.14 1404 784 2.49 / 822.31 6 6
5 0.72 180 13.96 348 874 3.36 / 823.19 6 17
Average= 5.28 (KJ/cycle)

Cycle 154 GMT 30/ 7/2017 6:56: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.12 31 13.87 538 231 0.23 / 817.19 6 6
2 971.64 80 6.07 1807 877 1.11 / 818.07 6 6
3 803.56 46 11.43 1656 871 1.98 / 818.94 6 6
4 0.28 181 13.98 350 886 2.87 / 819.83 6 22
Average= 5.29 (KJ/cycle)

Cycle 153 GMT 20/ 7/2017 13:43: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.16 30 13.75 538 222 0.22 / 809.58 6 6
2 1116.00 15 9.92 2147 319 0.54 / 809.89 6 6
3 1793.00 120 5.40 3086 2000 2.54 / 811.89 6 6
4 1787.88 80 6.68 3272 1749 4.29 / 813.64 6 6
5 1617.20 45 10.71 2989 1441 5.73 / 815.08 6 6
6 779.76 45 12.32 1690 937 6.67 / 816.02 6 6
7 0.64 181 14.00 371 940 7.61 / 816.96 6 23
Average= 5.30 (KJ/cycle)

Cycle 152 GMT 19/ 7/2017 10:22: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.24 31 13.68 538 228 0.23 / 806.05 6 6
2 970.92 80 4.61 1436 530 0.76 / 806.58 6 7
3 973.92 45 9.39 1892 799 1.56 / 807.38 6 6
4 798.24 46 11.43 1659 872 2.43 / 808.25 6 6
5 8.44 46 13.89 356 227 2.66 / 808.48 6 8
6 -0.16 181 13.93 348 877 3.53 / 809.35 6 33
Average= 5.29 (KJ/cycle)

Cycle 151 GMT 9/ 7/2017 16:15: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.40 31 13.87 538 231 0.23 / 802.61 6 6
2 999.28 80 4.66 1634 609 0.84 / 803.22 6 7
3 999.04 45 9.85 1955 867 1.71 / 804.09 6 6
4 820.36 45 11.47 1686 870 2.58 / 804.96 6 6
5 0.12 181 13.96 341 862 3.44 / 805.82 6 23
Average= 5.30 (KJ/cycle)

Cycle 150 GMT 29/ 6/2017 22: 8: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.76 31 13.93 538 232 0.23 / 799.74 6 6
2 976.64 80 6.09 1794 874 1.11 / 800.61 6 6
3 811.88 46 11.48 1668 881 1.99 / 801.49 6 6
4 0.00 181 13.95 351 886 2.87 / 802.38 6 23
Average= 5.31 (KJ/cycle)

Cycle 149 GMT 20/ 6/2017 4:57: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.12 29 13.75 500 199 0.20 / 792.38 6 6
2 1030.80 1 10.00 2057 21 0.22 / 792.40 6 6
3 1132.96 15 10.05 2131 321 0.54 / 792.72 6 6
4 1795.72 120 5.56 3093 2064 2.60 / 794.78 6 6
5 1790.84 80 7.19 3154 1814 4.42 / 796.60 6 6
6 1422.72 46 11.05 2674 1359 5.78 / 797.96 6 6
7 370.72 45 13.24 1008 601 6.38 / 798.56 6 7
8 0.20 181 14.00 375 950 7.33 / 799.51 6 28
Average= 5.33 (KJ/cycle)

Cycle 148 GMT 19/ 6/2017 1:31: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.20 29 13.87 538 216 0.22 / 789.07 6 6
2 1056.00 1 10.19 2019 21 0.24 / 789.09 6 6
3 1035.04 1 9.94 1980 20 0.26 / 789.11 6 6
4 1023.32 80 4.63 1450 537 0.79 / 789.65 6 7
5 1019.48 46 9.56 1975 869 1.66 / 790.51 6 6
6 667.56 46 12.13 1454 811 2.47 / 791.33 6 6
7 0.12 181 13.97 337 852 3.33 / 792.18 6 20
Average= 5.32 (KJ/cycle)

Cycle 147 GMT 9/ 6/2017 7:12: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.68 31 13.81 538 230 0.23 / 785.73 6 6
2 992.72 80 4.66 1622 605 0.84 / 786.34 6 7
3 989.72 46 9.91 1929 879 1.71 / 787.22 6 6
4 634.44 46 12.18 1402 786 2.50 / 788.00 6 6
5 0.08 181 13.98 336 850 3.35 / 788.85 6 21
Average= 5.33 (KJ/cycle)

Cycle 146 GMT 30/ 5/2017 13: 1: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.96 31 13.87 519 223 0.22 / 782.62 6 6
2 988.48 80 5.90 1790 845 1.07 / 783.46 6 6
3 823.08 46 11.35 1676 875 1.94 / 784.34 6 6
4 76.04 46 13.81 466 296 2.24 / 784.63 6 7
5 0.04 181 14.01 343 870 3.11 / 785.50 6 28
Average= 5.34 (KJ/cycle)

Cycle 145 GMT 20/ 5/2017 19:45: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.44 32 13.93 480 214 0.21 / 775.32 6 6
2 917.92 -1 13.93 480 0. 0.00 / 775.32 6 6
3 959.80 -1 13.93 480 0. 0.00 / 775.32 6 6
4 1207.36 15 9.44 2271 322 0.54 / 775.64 6 6
5 1750.44 120 5.41 3024 1963 2.50 / 777.60 6 6
6 1746.80 80 7.24 3097 1794 4.29 / 779.40 6 6
7 1382.60 46 11.16 2593 1331 5.62 / 780.73 6 6
8 523.44 46 12.93 1237 736 6.36 / 781.46 6 7
9 0.20 181 14.04 366 930 7.29 / 782.39 6 30
Average= 5.36 (KJ/cycle)

Cycle 144 GMT 19/ 5/2017 16:30: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.96 32 13.75 538 237 0.24 / 771.98 6 6
2 920.92 -1 13.75 538 0. 0.00 / 771.98 6 6
3 943.20 -1 13.75 538 0. 0.00 / 771.98 6 6
4 982.00 80 4.63 1499 555 0.79 / 772.53 6 7
5 986.32 46 9.56 1901 836 1.63 / 773.37 6 6
6 818.88 46 11.47 1681 887 2.51 / 774.26 6 6
7 0.16 181 13.99 334 846 3.36 / 775.10 6 21
Average= 5.35 (KJ/cycle)

Cycle 143 GMT 9/ 5/2017 22:27: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.84 30 13.81 538 223 0.22 / 768.52 6 6
2 995.16 80 4.67 1639 612 0.84 / 769.13 6 7
3 998.92 45 10.06 1938 877 1.71 / 770.01 6 6
4 830.24 45 11.55 1703 885 2.60 / 770.89 6 6
5 0.24 180 14.00 338 852 3.45 / 771.74 6 20
Average= 5.36 (KJ/cycle)

Cycle 142 GMT 30/ 4/2017 4:18: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.76 30 13.87 538 224 0.22 / 765.36 6 6
2 1011.44 80 5.91 1839 869 1.09 / 766.23 6 6
3 854.00 46 11.42 1724 906 2.00 / 767.13 6 6
4 85.96 45 13.78 486 301 2.30 / 767.43 6 7
5 -0.04 181 14.06 338 860 3.16 / 768.29 6 23
Average= 5.37 (KJ/cycle)

Cycle 141 GMT 20/ 4/2017 11: 1: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.00 27 13.81 538 201 0.20 / 758.02 6 6
2 1004.44 5 11.69 2000 117 0.32 / 758.14 6 6
3 1042.12 1 10.63 2076 22 0.34 / 758.16 6 6
4 1132.36 15 10.36 2143 333 0.67 / 758.49 6 6
5 1780.72 120 6.01 3274 2361 3.03 / 760.85 6 6
6 1772.68 80 8.09 3158 2044 5.08 / 762.90 6 6
7 955.92 46 12.01 1940 1072 6.15 / 763.97 6 6
8 13.28 46 14.05 372 240 6.39 / 764.21 6 7
9 0.20 181 14.15 360 922 7.31 / 765.13 6 27
Average= 5.39 (KJ/cycle)

Cycle 140 GMT 19/ 4/2017 7:36: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.40 27 14.00 519 196 0.20 / 754.18 6 6
2 1031.64 4 11.88 2000 95 0.29 / 754.28 6 6
3 1052.16 1 10.57 2134 23 0.31 / 754.30 6 6
4 1028.48 1 10.32 2057 21 0.34 / 754.32 6 6
5 1010.80 80 4.70 1794 675 1.01 / 755.00 6 7
6 1009.56 46 10.32 1972 936 1.95 / 755.93 6 6
7 649.52 46 12.40 1418 809 2.75 / 756.74 6 6
8 13.68 45 14.02 349 220 2.97 / 756.96 6 7
9 0.16 181 14.10 337 860 3.83 / 757.82 6 18
Average= 5.37 (KJ/cycle)

Cycle 139 GMT 9/ 4/2017 13:56: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.48 31 13.93 500 216 0.22 / 745.77 6 6
2 962.16 -1 13.93 500 0. 0.00 / 745.77 6 6
3 1109.88 15 4.73 1534 109 0.32 / 745.88 6 7
4 2005.40 120 4.66 1700 951 1.28 / 746.83 6 7
5 2009.28 80 4.75 2156 819 2.09 / 747.65 7 7
6 2072.44 46 6.71 3459 1068 3.16 / 748.72 6 6
7 1978.48 46 8.59 3465 1369 4.53 / 750.09 6 6
8 1825.72 46 9.92 3269 1492 6.02 / 751.58 6 6
9 1066.32 46 11.70 2117 1139 7.16 / 752.72 6 6
10 180.60 46 13.68 656 413 7.58 / 753.13 6 7
11 0.08 180 14.13 336 855 8.43 / 753.99 6 25
Average= 5.39 (KJ/cycle)

Cycle 138 GMT 30/ 3/2017 12:36: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.96 31 13.93 519 224 0.22 / 737.35 6 6
2 1100.24 15 4.72 1522 108 0.33 / 737.46 6 7
3 2001.04 120 4.65 1638 914 1.25 / 738.37 6 7
4 2005.00 80 4.72 2072 782 2.03 / 739.16 7 7
5 2072.28 46 6.28 3454 998 3.03 / 740.15 6 6
6 2000.48 46 7.97 3611 1324 4.35 / 741.48 6 6
7 1851.76 46 9.74 3260 1461 5.81 / 742.94 6 6
8 1304.12 46 11.23 2469 1275 7.09 / 744.21 6 6
9 268.08 46 13.51 801 498 7.58 / 744.71 6 7
10 0.04 181 14.16 330 846 8.43 / 745.56 6 19
Average= 5.36 (KJ/cycle)

Cycle 137 GMT 20/ 3/2017 10:54: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.16 31 14.00 500 217 0.22 / 728.79 6 6
2 1109.04 15 4.72 1515 107 0.32 / 728.90 6 7
3 2002.12 120 4.65 1612 899 1.22 / 729.80 6 7
4 2006.64 80 4.71 2046 771 1.99 / 730.57 7 7
5 2081.12 46 6.27 3401 981 2.98 / 731.55 6 6
6 2008.56 46 7.85 3622 1308 4.28 / 732.86 6 6
7 1868.32 46 9.66 3290 1462 5.75 / 734.32 6 6
8 1478.92 45 10.89 2718 1332 7.08 / 735.65 6 6
9 422.88 45 13.14 1066 630 7.71 / 736.28 6 7
10 0.28 180 14.15 331 843 8.55 / 737.13 6 19
Average= 5.34 (KJ/cycle)

Cycle 136 GMT 10/ 3/2017 9:26: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.48 31 14.00 519 225 0.23 / 720.08 6 6
2 1215.12 14 4.69 1432 94 0.32 / 720.18 6 7
3 2004.92 120 4.62 1543 855 1.17 / 721.03 6 7
4 2009.32 80 4.67 1949 728 1.90 / 721.76 7 7
5 2103.80 46 6.06 3304 921 2.82 / 722.68 6 6
6 2031.36 46 7.45 3670 1258 4.08 / 723.94 6 6
7 1894.36 46 9.39 3330 1438 5.52 / 725.38 6 6
8 1530.40 46 10.72 2814 1388 6.91 / 726.76 6 6
9 504.00 46 12.97 1207 720 7.63 / 727.48 6 6
10 5.32 46 14.08 333 216 7.84 / 727.70 6 6
11 -0.12 180 14.15 344 876 8.72 / 728.58 6 25
Average= 5.32 (KJ/cycle)

Cycle 135 GMT 28/ 2/2017 7:39: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.20 31 13.87 538 231 0.23 / 711.36 6 6
2 1111.88 15 4.69 1419 100 0.33 / 711.46 6 7
3 2002.32 120 4.61 1450 802 1.13 / 712.26 6 7
4 2006.00 80 4.66 1823 680 1.81 / 712.94 7 7
5 2089.68 45 5.87 3196 844 2.66 / 713.79 6 6
6 2035.00 46 7.21 3575 1186 3.84 / 714.97 6 6
7 1923.16 46 9.23 3353 1424 5.27 / 716.39 6 6
8 1566.84 46 10.70 2863 1409 6.68 / 717.80 6 6
9 739.68 46 12.47 1588 911 7.59 / 718.71 6 6
10 42.32 46 14.00 397 256 7.84 / 718.97 6 7
11 0.24 180 14.15 348 886 8.73 / 719.86 6 20
Average= 5.29 (KJ/cycle)

Cycle 134 GMT 18/ 2/2017 6:13: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.84 31 13.81 538 230 0.23 / 704.00 6 6
2 1122.28 10 4.69 1427 67 0.30 / 704.07 6 7
3 2005.24 75 4.63 1438 499 0.80 / 704.57 6 7
4 2013.08 56 4.79 1961 526 1.32 / 705.09 7 7
5 2084.72 31 5.90 3171 580 1.90 / 705.67 6 6
6 2039.32 31 7.26 3480 783 2.69 / 706.45 6 6
7 1963.20 31 8.85 3424 939 3.63 / 707.39 6 6
8 1813.36 31 10.15 3212 1011 4.64 / 708.40 6 6
9 1454.64 31 11.21 2723 946 5.58 / 709.35 6 6
10 872.88 30 12.38 1828 679 6.26 / 710.03 6 6
11 111.44 30 13.82 531 220 6.48 / 710.25 6 6
12 0.00 181 14.10 344 878 7.36 / 711.13 6 21
Average= 5.27 (KJ/cycle)

Cycle 133 GMT 8/ 2/2017 4: 0: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.24 31 13.93 519 224 0.22 / 696.78 6 6
2 1130.76 10 4.69 1326 62 0.29 / 696.84 6 7
3 2006.00 75 4.60 1342 463 0.75 / 697.31 6 7
4 2011.28 56 4.71 1824 481 1.23 / 697.79 7 7
5 2074.40 31 5.59 3030 525 1.76 / 698.31 6 6
6 2055.24 31 6.58 3478 709 2.46 / 699.02 6 6
7 1977.64 31 8.34 3445 891 3.36 / 699.91 6 6
8 1872.64 31 9.71 3334 1004 4.36 / 700.92 6 6
9 1541.12 31 11.09 2791 960 5.32 / 701.88 6 6
10 1000.92 30 12.21 1998 732 6.05 / 702.61 6 6
11 219.16 30 13.52 723 293 6.34 / 702.90 6 6
12 0.64 180 14.08 342 867 7.21 / 703.77 6 14
Average= 5.25 (KJ/cycle)

Cycle 132 GMT 29/ 1/2017 1:27: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.52 31 13.93 538 232 0.23 / 689.63 6 6
2 1115.96 10 4.69 1331 62 0.29 / 689.69 6 7
3 2004.72 75 4.61 1358 470 0.76 / 690.16 6 7
4 2010.88 56 4.71 1830 483 1.25 / 690.64 7 7
5 2074.48 30 5.64 3082 521 1.77 / 691.16 6 6
6 2046.16 30 6.97 3353 701 2.47 / 691.86 6 6
7 1952.36 30 8.61 3449 891 3.36 / 692.76 6 6
8 1827.08 31 10.10 3247 1017 4.38 / 693.77 6 6
9 1480.88 31 11.26 2775 969 5.35 / 694.74 6 6
10 920.80 30 12.40 1887 702 6.05 / 695.44 6 6
11 138.40 30 13.72 586 241 6.29 / 695.68 6 6
12 0.40 181 14.09 343 875 7.16 / 696.56 6 21
Average= 5.24 (KJ/cycle)

Cycle 131 GMT 18/ 1/2017 23:22: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.92 31 13.81 538 230 0.23 / 682.33 6 6
2 1111.80 9 4.69 1312 55 0.29 / 682.38 6 7
3 2001.68 75 4.61 1337 462 0.75 / 682.85 6 7
4 2007.44 55 4.71 1813 470 1.22 / 683.32 7 7
5 2073.64 30 5.73 3068 527 1.75 / 683.84 6 6
6 2039.72 30 6.87 3502 722 2.47 / 684.57 6 6
7 1958.00 30 9.00 3417 923 3.39 / 685.49 6 6
8 1829.92 30 10.35 3265 1014 4.40 / 686.50 6 6
9 1652.88 30 11.16 3010 1008 5.41 / 687.51 6 6
10 1029.44 30 12.24 2066 759 6.17 / 688.27 6 6
11 108.52 30 13.77 545 225 6.39 / 688.49 6 6
12 0.04 181 14.07 354 902 7.30 / 689.39 6 24
Average= 5.22 (KJ/cycle)

Cycle 130 GMT 8/ 1/2017 21:14: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.76 31 13.87 538 231 0.23 / 675.08 6 6
2 1121.24 9 4.69 1283 54 0.29 / 675.13 6 7
3 2003.20 75 4.60 1327 458 0.74 / 675.59 6 7
4 2009.92 56 4.71 1816 479 1.22 / 676.07 7 7
5 2081.48 30 5.71 3087 529 1.75 / 676.60 6 6
6 2045.00 30 7.10 3530 752 2.50 / 677.35 6 6
7 1945.36 30 9.33 3385 947 3.45 / 678.30 6 6
8 1809.48 30 10.59 3222 1024 4.47 / 679.32 6 6
9 1630.00 30 11.34 2959 1007 5.48 / 680.33 6 6
10 818.28 30 12.64 1727 655 6.14 / 680.98 6 6
11 75.72 30 13.85 488 203 6.34 / 681.19 6 7
12 0.04 181 14.05 359 913 7.25 / 682.10 6 23
Average= 5.21 (KJ/cycle)

Cycle 129 GMT 29/12/2016 19:14:58

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.80 31 13.93 538 232 0.23 / 667.95 6 6
2 1109.24 9 4.69 1302 55 0.29 / 668.00 6 7
3 2003.24 75 4.61 1336 462 0.75 / 668.46 6 7
4 2011.00 56 4.71 1842 486 1.24 / 668.95 7 7
5 2076.20 31 5.80 3180 572 1.81 / 669.52 6 6
6 2029.40 30 7.57 3584 814 2.62 / 670.34 6 6
7 1948.12 31 9.75 3435 1038 3.66 / 671.37 6 6
8 1772.64 31 10.95 3183 1080 4.74 / 672.45 6 6
9 1223.04 31 12.07 2356 882 5.62 / 673.34 6 6
10 458.20 30 13.23 1126 447 6.07 / 673.78 6 6
11 19.56 30 14.00 377 158 6.23 / 673.94 6 7
12 0.04 181 14.10 355 906 7.13 / 674.85 6 25
Average= 5.19 (KJ/cycle)

Cycle 128 GMT 19/12/2016 17: 7: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.04 31 14.00 519 225 0.23 / 661.17 6 6
2 1112.24 9 4.69 1321 56 0.28 / 661.23 6 7
3 2001.32 75 4.62 1394 483 0.76 / 661.71 6 7
4 2007.32 56 4.76 1941 517 1.28 / 662.23 7 7
5 2065.20 30 6.16 3373 623 1.90 / 662.85 6 6
6 2006.64 30 8.57 3563 916 2.82 / 663.77 6 6
7 1872.60 30 10.51 3340 1053 3.87 / 664.82 6 6
8 1544.16 30 11.62 2877 1003 4.88 / 665.82 6 6
9 969.64 30 12.52 1975 742 5.62 / 666.56 6 6
10 167.40 30 13.65 651 267 5.89 / 666.83 6 6
11 -0.12 181 14.12 346 884 6.77 / 667.71 6 22
Average= 5.18 (KJ/cycle)

Cycle 127 GMT 9/12/2016 15:15: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.20 31 13.93 538 232 0.23 / 654.23 6 6
2 1102.24 9 4.69 1355 57 0.29 / 654.28 6 7
3 2006.84 75 4.63 1452 504 0.79 / 654.79 6 7
4 2013.12 56 4.82 2048 553 1.35 / 655.34 7 7
5 2069.04 31 6.87 3528 751 2.10 / 656.09 6 6
6 1988.56 30 9.69 3512 1021 3.12 / 657.11 6 6
7 1842.96 31 11.06 3296 1130 4.25 / 658.24 6 6
8 1489.16 31 11.84 2826 1037 5.29 / 659.28 6 6
9 711.76 30 12.97 1549 603 5.89 / 659.88 6 6
10 56.76 30 13.99 435 183 6.07 / 660.06 6 6
11 0.16 180 14.15 346 881 6.95 / 660.95 6 22
Average= 5.16 (KJ/cycle)

Cycle 126 GMT 29/11/2016 13:18:59

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.52 30 13.93 538 225 0.22 / 647.25 6 6
2 1123.00 9 4.69 1350 57 0.28 / 647.31 6 7
3 2005.44 75 4.65 1510 527 0.81 / 647.83 6 7
4 2011.92 56 4.85 2176 591 1.40 / 648.43 7 7
5 2056.48 30 7.41 3659 813 2.21 / 649.24 6 6
6 1964.16 31 10.13 3477 1092 3.30 / 650.33 6 6
7 1811.92 30 11.31 3248 1102 4.41 / 651.43 6 6
8 1414.92 31 12.07 2651 992 5.40 / 652.43 6 6
9 608.44 30 13.13 1363 537 5.94 / 652.96 6 6
10 33.96 30 13.98 404 169 6.11 / 653.13 6 7
11 -0.16 181 14.12 337 861 6.97 / 653.99 6 30
Average= 5.15 (KJ/cycle)

Cycle 125 GMT 19/11/2016 12: 6: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.36 30 13.81 538 223 0.22 / 640.40 6 6
2 1132.52 9 4.69 1417 60 0.28 / 640.45 6 7
3 2000.44 75 4.67 1640 574 0.86 / 641.03 6 7
4 2004.96 56 4.99 2368 662 1.52 / 641.69 7 7
5 2042.24 30 8.16 3724 912 2.43 / 642.60 6 6
6 1945.80 31 10.57 3424 1122 3.55 / 643.72 6 6
7 1778.76 31 11.41 3257 1152 4.70 / 644.88 6 6
8 1184.44 31 12.39 2294 881 5.59 / 645.76 6 6
9 372.68 30 13.43 986 397 5.98 / 646.16 6 7
10 0.20 181 14.12 341 872 6.85 / 647.03 6 22
Average= 5.14 (KJ/cycle)

Cycle 124 GMT 9/11/2016 11:16: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.04 30 13.93 538 225 0.22 / 633.66 6 6
2 1110.28 9 4.69 1393 59 0.28 / 633.72 6 7
3 2002.76 75 4.70 1740 613 0.90 / 634.33 6 7
4 2007.84 56 5.09 2576 734 1.63 / 635.06 7 6
5 2017.80 30 9.35 3534 991 2.62 / 636.05 6 6
6 1918.20 31 11.16 3382 1170 3.79 / 637.22 6 6
7 1570.72 31 11.89 2904 1070 4.86 / 638.29 6 6
8 978.00 31 12.66 1991 781 5.64 / 639.08 6 6
9 84.32 30 13.92 499 208 5.85 / 639.28 6 7
10 0.08 181 14.09 348 888 6.74 / 640.17 6 25
Average= 5.12 (KJ/cycle)

Cycle 123 GMT 30/10/2016 10:22: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.76 29 13.81 557 223 0.22 / 626.99 6 6
2 1028.96 1 10.88 2019 22 0.25 / 627.01 6 6
3 1133.80 9 4.70 1418 60 0.31 / 627.07 6 7
4 2002.28 75 4.71 1774 627 0.93 / 627.70 6 7
5 2006.60 56 5.22 2639 771 1.70 / 628.47 7 6
6 2009.16 30 10.20 3565 1091 2.79 / 629.56 6 6
7 1872.88 30 11.49 3329 1148 3.94 / 630.71 6 6
8 1509.52 31 12.07 2802 1048 4.99 / 631.76 6 6
9 704.76 31 13.01 1536 619 5.61 / 632.38 6 6
10 26.96 30 14.05 391 165 5.77 / 632.54 6 7
11 -0.04 181 14.12 349 892 6.67 / 633.43 6 23
Average= 5.11 (KJ/cycle)

Cycle 122 GMT 20/10/2016 9:20: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.32 31 14.06 480 209 0.21 / 620.76 6 6
2 962.56 -1 14.06 480 0. 0.00 / 620.76 6 6
3 1112.92 6 4.69 1300 37 0.25 / 620.79 6 7
4 2005.32 11 4.75 1568 82 0.33 / 620.88 6 7
5 2007.96 56 4.73 1871 496 0.82 / 621.37 7 7
6 2051.32 30 7.56 3743 849 1.67 / 622.22 6 6
7 1971.16 31 10.73 3478 1157 2.83 / 623.38 6 6
8 1808.24 31 11.51 3248 1159 3.99 / 624.54 6 6
9 1220.12 31 12.33 2368 905 4.89 / 625.44 6 6
10 432.76 30 13.33 1095 438 5.33 / 625.88 6 7
11 0.20 181 14.06 348 886 6.22 / 626.77 6 28
Average= 5.10 (KJ/cycle)

Cycle 121 GMT 10/10/2016 8: 3: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.48 31 13.81 538 230 0.23 / 614.56 6 6
2 1112.92 6 4.69 1332 37 0.27 / 614.60 6 7
3 2003.40 11 4.75 1599 84 0.35 / 614.68 6 7
4 2005.84 56 4.76 1946 519 0.87 / 615.20 7 7
5 2056.04 31 8.45 3557 932 1.80 / 616.13 6 6
6 1938.60 30 11.04 3443 1140 2.94 / 617.27 6 6
7 1761.92 31 11.64 3145 1135 4.08 / 618.41 6 6
8 1164.68 31 12.47 2268 877 4.95 / 619.28 6 6
9 337.20 30 13.46 938 379 5.33 / 619.66 6 7
10 0.12 181 14.12 347 887 6.22 / 620.55 6 20
Average= 5.09 (KJ/cycle)

Cycle 120 GMT 30/ 9/2016 6:57: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.32 31 14.00 557 242 0.24 / 608.29 6 6
2 1213.48 6 4.69 1320 37 0.28 / 608.32 6 7
3 2002.08 11 4.76 1688 88 0.37 / 608.41 6 6
4 2004.28 56 4.79 2110 566 0.93 / 608.98 6 7
5 2040.72 30 9.52 3529 1008 1.94 / 609.99 6 6
6 1930.32 31 11.23 3413 1188 3.13 / 611.18 6 6
7 1756.64 31 11.67 3170 1147 4.28 / 612.32 6 6
8 1142.28 31 12.46 2248 868 5.14 / 613.19 6 6
9 149.32 30 13.85 611 254 5.40 / 613.44 6 7
10 -0.08 181 14.10 347 886 6.28 / 614.33 6 29
Average= 5.08 (KJ/cycle)

Cycle 119 GMT 20/ 9/2016 6:18:59

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.20 31 14.06 557 243 0.24 / 602.06 6 6
2 1215.60 6 4.69 1301 37 0.28 / 602.10 6 7
3 2002.36 11 4.76 1703 89 0.37 / 602.19 6 6
4 2004.92 56 4.82 2257 609 0.98 / 602.80 6 7
5 2043.36 31 10.11 3608 1131 2.11 / 603.93 6 6
6 1913.40 31 11.29 3438 1203 3.31 / 605.13 6 6
7 1551.24 31 11.96 2845 1055 4.37 / 606.19 6 6
8 968.80 31 12.71 1967 775 5.14 / 606.96 6 6
9 79.56 30 13.99 494 207 5.35 / 607.17 6 6
10 -0.08 180 14.13 345 877 6.23 / 608.05 6 21
Average= 5.07 (KJ/cycle)

Cycle 118 GMT 10/ 9/2016 5:13: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.64 31 14.06 538 234 0.23 / 595.92 6 6
2 1204.16 3 4.69 1249 18 0.25 / 595.94 6 7
3 2002.72 11 4.70 1460 75 0.33 / 596.01 6 7
4 2004.60 55 4.80 2200 581 0.91 / 596.59 7 6
5 2054.16 30 10.43 3603 1127 2.04 / 597.72 6 6
6 1936.32 30 11.30 3417 1158 3.19 / 598.88 6 6
7 1581.60 30 12.00 2917 1050 4.24 / 599.93 6 6
8 990.48 30 12.68 2028 771 5.02 / 600.70 6 6
9 172.28 30 13.87 646 269 5.28 / 600.97 6 6
10 0.04 181 14.21 330 849 6.13 / 601.82 6 29
Average= 5.06 (KJ/cycle)

Cycle 117 GMT 31/ 8/2016 4: 3: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.92 30 14.12 519 220 0.22 / 589.78 6 6
2 1128.08 3 4.69 1278 18 0.24 / 589.80 6 7
3 2000.64 11 4.73 1518 79 0.32 / 589.88 6 7
4 2002.80 56 4.85 2412 655 0.97 / 590.53 7 6
5 2040.24 31 10.91 3584 1212 2.18 / 591.74 6 6
6 1910.52 30 11.51 3368 1163 3.35 / 592.91 6 6
7 1539.64 31 12.04 2863 1069 4.42 / 593.98 6 6
8 762.12 31 13.03 1651 667 5.08 / 594.64 6 6
9 78.28 30 14.06 480 202 5.28 / 594.85 6 6
10 0.28 180 14.24 328 841 6.13 / 595.69 6 16
Average= 5.05 (KJ/cycle)

Cycle 116 GMT 21/ 8/2016 3: 6: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.56 30 14.06 538 227 0.23 / 583.63 6 6
2 1125.68 3 4.69 1288 18 0.25 / 583.64 6 7
3 2001.52 11 4.72 1503 78 0.32 / 583.72 6 7
4 2003.92 56 4.88 2453 670 0.99 / 584.39 7 6
5 2038.00 31 11.01 3587 1224 2.22 / 585.62 6 6
6 1895.88 30 11.53 3404 1177 3.40 / 586.79 6 6
7 1531.44 31 12.09 2839 1064 4.46 / 587.86 6 6
8 742.92 31 13.04 1613 652 5.11 / 588.51 6 6
9 72.84 30 14.10 462 195 5.31 / 588.70 6 6
10 0.04 181 14.24 332 856 6.16 / 589.56 6 25
Average= 5.04 (KJ/cycle)

Cycle 115 GMT 11/ 8/2016 2: 8: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.48 30 14.06 557 235 0.23 / 577.33 6 6
2 1117.24 3 4.69 1317 19 0.25 / 577.35 6 7
3 2003.32 11 4.75 1568 82 0.34 / 577.43 6 6
4 2005.08 56 4.91 2659 731 1.07 / 578.16 6 6
5 2037.72 31 11.16 3626 1254 2.32 / 579.41 6 6
6 1897.44 31 11.59 3424 1230 3.55 / 580.64 6 6
7 1530.12 31 12.10 2850 1069 4.62 / 581.71 6 6
8 744.44 31 13.04 1630 659 5.28 / 582.37 6 6
9 17.52 30 14.22 361 154 5.43 / 582.53 6 6
10 0.04 180 14.22 341 873 6.31 / 583.40 6 18
Average= 5.03 (KJ/cycle)

Cycle 114 GMT 1/ 8/2016 1: 6: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.96 30 14.06 519 219 0.22 / 571.01 6 6
2 1109.76 3 4.69 1316 19 0.24 / 571.03 6 7
3 2001.84 11 4.76 1653 87 0.32 / 571.12 6 6
4 2003.84 56 4.96 2924 812 1.14 / 571.93 6 6
5 2029.96 30 11.33 3573 1214 2.35 / 573.14 6 6
6 1896.76 30 11.67 3401 1191 3.54 / 574.33 6 6
7 1529.88 30 12.15 2855 1041 4.58 / 575.38 6 6
8 721.24 31 13.07 1579 640 5.22 / 576.02 6 6
9 73.76 31 14.07 469 205 5.43 / 576.22 6 7
10 0.16 181 14.22 339 873 6.30 / 577.09 6 24
Average= 5.02 (KJ/cycle)

Cycle 113 GMT 22/ 7/2016 0: 8: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.48 30 14.12 557 236 0.24 / 564.69 6 6
2 1110.32 3 4.69 1317 19 0.25 / 564.71 6 7
3 2002.72 11 4.77 1695 89 0.34 / 564.80 6 6
4 2003.84 56 5.09 3169 903 1.25 / 565.70 6 6
5 2010.12 31 11.50 3545 1264 2.51 / 566.96 6 6
6 1877.44 31 11.69 3382 1226 3.74 / 568.19 6 6
7 1514.12 31 12.15 2866 1079 4.82 / 569.27 6 6
8 718.08 31 13.09 1578 640 5.46 / 569.91 6 6
9 0.12 181 14.15 345 884 6.34 / 570.79 6 26
Average= 5.01 (KJ/cycle)

Cycle 112 GMT 11/ 7/2016 22:55: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.20 30 14.00 557 234 0.23 / 558.18 6 6
2 1126.56 3 4.72 1394 20 0.25 / 558.20 6 7
3 2006.72 11 4.83 1930 103 0.36 / 558.31 6 6
4 2009.04 56 5.23 3527 1033 1.39 / 559.34 6 6
5 2023.76 31 11.46 3589 1275 2.66 / 560.61 6 6
6 1881.52 31 11.71 3412 1239 3.90 / 561.85 6 6
7 1353.24 31 12.33 2558 978 4.88 / 562.83 6 6
8 591.80 30 13.28 1347 537 5.42 / 563.37 6 6
9 34.68 30 14.17 406 173 5.59 / 563.54 6 7
10 -0.08 181 14.19 356 914 6.50 / 564.45 6 23
Average= 5.00 (KJ/cycle)

Cycle 111 GMT 1/ 7/2016 21:41: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.04 30 14.00 557 234 0.23 / 552.22 6 6
2 1104.64 3 4.72 1461 21 0.25 / 552.24 6 7
3 2004.76 11 4.89 2184 117 0.37 / 552.36 6 6
4 2006.84 56 7.21 3568 1441 1.81 / 553.80 6 6
5 1896.72 30 11.68 3350 1174 2.99 / 554.98 6 6
6 1549.72 31 12.06 2869 1073 4.06 / 556.05 6 6
7 962.88 30 12.77 1975 757 4.82 / 556.80 6 6
8 70.40 31 13.98 494 214 5.03 / 557.02 6 7
9 0.16 181 14.09 365 931 5.96 / 557.95 6 27
Average= 4.98 (KJ/cycle)

Cycle 110 GMT 21/ 6/2016 20:56: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.20 30 14.00 538 226 0.23 / 546.00 6 6
2 2001.32 55 6.10 3236 1086 1.31 / 547.09 6 6
3 1949.76 30 11.52 3485 1204 2.52 / 548.29 6 6
4 1803.36 30 11.80 3228 1143 3.66 / 549.43 6 6
5 1241.40 30 12.42 2397 893 4.55 / 550.33 6 6
6 618.80 30 13.24 1400 556 5.11 / 550.88 6 7
7 12.80 30 14.15 388 165 5.27 / 551.05 6 8
8 -0.32 181 14.06 370 942 6.21 / 551.99 6 25
Average= 4.97 (KJ/cycle)

Cycle 109 GMT 11/ 6/2016 20:21: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.56 30 14.00 557 234 0.23 / 540.17 6 6
2 2007.44 55 6.92 3240 1233 1.47 / 541.40 6 6
3 1930.44 30 11.49 3454 1191 2.66 / 542.59 6 6
4 1760.72 30 11.77 3187 1125 3.78 / 543.72 6 6
5 1135.56 30 12.51 2241 841 4.62 / 544.56 6 6
6 171.88 30 13.84 676 281 4.90 / 544.84 6 7
7 0.00 181 14.08 367 935 5.84 / 545.77 6 27
Average= 4.96 (KJ/cycle)

Cycle 108 GMT 1/ 6/2016 20: 9: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.60 30 14.06 538 227 0.23 / 534.33 6 6
2 2003.20 55 7.32 3300 1329 1.56 / 535.65 6 6
3 1906.12 30 11.48 3430 1181 2.74 / 536.84 6 6
4 1564.52 30 12.01 2896 1043 3.78 / 537.88 6 6
5 1154.24 30 12.48 2260 846 4.63 / 538.73 6 6
6 131.28 30 13.86 600 249 4.88 / 538.97 6 7
7 0.24 181 14.07 377 960 5.84 / 539.93 6 26
Average= 4.95 (KJ/cycle)

Cycle 107 GMT 22/ 5/2016 20: 5: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.04 30 14.12 519 220 0.22 / 528.73 6 6
2 2002.72 55 7.67 3381 1426 1.65 / 530.16 6 6
3 1881.52 30 11.60 3356 1168 2.81 / 531.32 6 6
4 1528.68 30 12.02 2831 1021 3.83 / 532.34 6 6
5 751.44 30 13.01 1614 630 4.46 / 532.97 6 6
6 79.16 30 14.05 496 209 4.67 / 533.18 6 7
7 0.04 181 14.12 358 915 5.59 / 534.10 6 25
Average= 4.95 (KJ/cycle)

Cycle 106 GMT 12/ 5/2016 19:51: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.52 29 14.06 557 227 0.23 / 522.96 6 6
2 1037.68 1 12.37 2057 25 0.25 / 522.99 6 6
3 2014.72 55 8.51 3385 1584 1.84 / 524.57 6 6
4 1877.52 31 11.58 3385 1215 3.05 / 525.79 6 6
5 1501.64 31 12.06 2820 1054 4.11 / 526.84 6 6
6 698.80 30 13.04 1542 603 4.71 / 527.44 6 6
7 55.40 30 14.07 454 192 4.90 / 527.63 6 7
8 0.08 180 14.14 344 876 5.78 / 528.51 6 27
Average= 4.94 (KJ/cycle)

Cycle 105 GMT 2/ 5/2016 19:28: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.44 30 14.12 500 212 0.21 / 517.31 6 6
2 961.60 -1 14.12 500 0. 0.00 / 517.31 6 6
3 2001.12 55 8.56 3378 1590 1.80 / 518.90 6 6
4 1865.00 30 11.56 3342 1159 2.96 / 520.06 6 6
5 1485.12 30 12.08 2768 1003 3.96 / 521.06 6 6
6 695.40 30 13.10 1521 598 4.56 / 521.66 6 6
7 55.68 30 14.11 451 191 4.75 / 521.85 6 7
8 0.04 181 14.14 345 883 5.64 / 522.73 6 26
Average= 4.93 (KJ/cycle)

Cycle 104 GMT 22/ 4/2016 19:26: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.08 29 14.12 538 220 0.22 / 511.62 6 6
2 1023.36 1 11.13 2076 23 0.24 / 511.65 6 6
3 2002.00 55 8.89 3413 1669 1.91 / 513.32 6 6
4 1857.80 30 11.60 3318 1155 3.07 / 514.47 6 6
5 1473.16 30 12.12 2735 994 4.06 / 515.46 6 6
6 658.28 30 13.12 1485 584 4.65 / 516.05 6 6
7 23.72 30 14.17 395 168 4.81 / 516.22 6 7
8 0.00 181 14.14 344 880 5.69 / 517.10 6 25
Average= 4.92 (KJ/cycle)

Cycle 103 GMT 12/ 4/2016 19:29: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.76 31 14.06 519 226 0.23 / 505.98 6 6
2 967.76 -1 14.06 519 0. 0.00 / 505.98 6 6
3 2003.88 55 8.79 3422 1654 1.88 / 507.64 6 6
4 1860.08 30 11.61 3342 1164 3.04 / 508.80 6 6
5 1311.72 30 12.31 2514 928 3.97 / 509.73 6 6
6 713.96 30 13.09 1549 608 4.58 / 510.34 6 6
7 28.04 30 14.18 396 168 4.75 / 510.50 6 6
8 0.04 181 14.15 351 899 5.65 / 511.40 6 23
Average= 4.92 (KJ/cycle)

Cycle 102 GMT 2/ 4/2016 19:17: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.48 31 14.06 538 234 0.23 / 500.24 6 6
2 2001.00 55 8.92 3384 1660 1.89 / 501.90 6 6
3 1860.00 31 11.60 3305 1188 3.08 / 503.09 6 6
4 1474.44 30 12.11 2744 997 4.08 / 504.09 6 6
5 690.16 30 13.11 1523 599 4.68 / 504.69 6 6
6 10.56 30 14.23 365 156 4.83 / 504.84 6 6
7 0.00 181 14.13 357 913 5.75 / 505.75 6 27
Average= 4.91 (KJ/cycle)

Cycle 101 GMT 23/ 3/2016 19:10: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.64 31 14.12 538 235 0.24 / 494.66 6 6
2 2006.44 55 9.12 3397 1704 1.94 / 496.36 6 6
3 1851.76 30 11.62 3313 1155 3.09 / 497.52 6 6
4 1301.20 30 12.31 2489 919 4.01 / 498.44 6 6
5 526.64 30 13.33 1255 502 4.52 / 498.94 6 6
6 56.48 30 14.10 456 193 4.71 / 499.13 6 7
7 0.00 181 14.16 342 877 5.58 / 500.01 6 28
Average= 4.90 (KJ/cycle)

Cycle 100 GMT 13/ 3/2016 18:47: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.80 31 14.12 538 235 0.24 / 489.05 6 6
2 2001.72 55 9.24 3437 1747 1.98 / 490.80 6 6
3 1846.88 30 11.61 3310 1153 3.14 / 491.95 6 6
4 1287.08 30 12.28 2475 912 4.05 / 492.86 6 6
5 527.64 30 13.36 1249 501 4.55 / 493.36 6 6
6 1.68 30 14.26 347 148 4.70 / 493.51 6 7
7 0.00 180 14.10 359 911 5.61 / 494.42 6 23
Average= 4.90 (KJ/cycle)

Cycle 99 GMT 3/ 3/2016 18:20: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.88 30 14.12 538 228 0.23 / 483.29 6 6
2 2005.52 55 9.27 3468 1768 2.00 / 485.06 6 6
3 1851.76 30 11.67 3299 1155 3.15 / 486.21 6 6
4 1288.32 30 12.34 2481 918 4.07 / 487.13 6 6
5 684.36 30 13.10 1517 596 4.67 / 487.73 6 6
6 37.44 30 14.12 427 181 4.85 / 487.91 6 7
7 0.08 181 14.10 356 909 5.76 / 488.81 6 30
Average= 4.89 (KJ/cycle)

Cycle 98 GMT 22/ 2/2016 18:18: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.28 30 14.12 538 228 0.23 / 477.44 6 6
2 2001.32 56 9.26 3464 1796 2.02 / 479.23 6 6
3 1843.68 31 11.67 3302 1195 3.22 / 480.43 6 6
4 1288.52 30 12.30 2482 916 4.13 / 481.34 6 6
5 683.68 31 13.13 1512 615 4.75 / 481.96 6 6
6 43.52 31 14.14 430 188 4.94 / 482.15 6 7
7 0.12 181 14.13 357 913 5.85 / 483.06 6 24
Average= 4.88 (KJ/cycle)

Cycle 97 GMT 12/ 2/2016 18:11: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.80 30 14.12 538 228 0.23 / 471.69 6 6
2 2002.92 56 9.25 3466 1795 2.02 / 473.48 6 6
3 1835.00 31 11.66 3297 1192 3.22 / 474.67 6 6
4 1264.68 31 12.38 2445 938 4.15 / 475.61 6 6
5 496.20 31 13.41 1196 497 4.65 / 476.11 6 6
6 59.44 31 14.16 453 199 4.85 / 476.31 6 7
7 0.68 181 14.17 351 900 5.75 / 477.21 6 25
Average= 4.87 (KJ/cycle)

Cycle 96 GMT 2/ 2/2016 18: 6: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.60 30 14.06 538 227 0.23 / 465.93 6 6
2 2002.84 55 9.37 3491 1799 2.03 / 467.73 6 6
3 1848.60 30 11.69 3294 1155 3.18 / 468.89 6 6
4 1284.36 30 12.35 2483 920 4.10 / 469.81 6 6
5 670.76 30 13.17 1504 594 4.70 / 470.40 6 6
6 17.84 30 14.20 376 160 4.86 / 470.56 6 7
7 -0.04 181 14.10 351 896 5.75 / 471.46 6 28
Average= 4.86 (KJ/cycle)

Cycle 95 GMT 23/ 1/2016 18:10: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.40 30 14.12 519 220 0.22 / 460.09 6 6
2 2001.04 56 9.50 3441 1831 2.05 / 461.92 6 6
3 1836.64 30 11.67 3316 1161 3.21 / 463.08 6 6
4 1447.12 30 12.16 2709 988 4.20 / 464.07 6 6
5 621.72 31 13.28 1408 580 4.78 / 464.65 6 6
6 14.48 31 14.23 371 164 4.94 / 464.81 6 6
7 0.04 181 14.11 351 896 5.84 / 465.71 6 35
Average= 4.85 (KJ/cycle)

Cycle 94 GMT 13/ 1/2016 18:25: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.36 30 14.06 557 235 0.23 / 454.54 6 6
2 2004.80 56 9.48 3475 1845 2.08 / 456.38 6 6
3 1843.24 30 11.65 3321 1161 3.24 / 457.54 6 6
4 1287.40 30 12.39 2480 922 4.16 / 458.47 6 6
5 503.88 31 13.44 1211 505 4.67 / 458.97 6 6
6 -0.04 181 14.12 351 897 5.56 / 459.87 6 21
Average= 4.84 (KJ/cycle)

Cycle 93 GMT 3/ 1/2016 18:17: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.08 30 14.12 538 228 0.23 / 448.83 6 6
2 2003.04 56 9.54 3474 1856 2.08 / 450.69 6 6
3 1839.36 30 11.66 3352 1173 3.26 / 451.86 6 6
4 1269.44 31 12.38 2461 944 4.20 / 452.80 6 6
5 647.04 31 13.21 1458 597 4.80 / 453.40 6 6
6 0.00 181 14.12 354 905 5.70 / 454.30 6 19
Average= 4.83 (KJ/cycle)

Cycle 92 GMT 24/12/2015 18:29: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.68 30 14.12 538 228 0.23 / 443.22 6 6
2 2002.00 56 9.60 3461 1861 2.09 / 445.08 6 6
3 1837.92 30 11.69 3315 1163 3.25 / 446.24 6 6
4 1273.88 31 12.40 2477 952 4.20 / 447.19 6 6
5 476.28 31 13.48 1164 486 4.69 / 447.68 6 6
6 0.12 181 14.11 361 922 5.61 / 448.60 6 23
Average= 4.82 (KJ/cycle)

Cycle 91 GMT 14/12/2015 18:18:59

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.72 30 14.00 557 234 0.23 / 437.60 6 6
2 2005.52 56 9.67 3465 1876 2.11 / 439.47 6 6
3 1846.32 30 11.74 3289 1158 3.27 / 440.63 6 6
4 1278.76 31 12.40 2467 948 4.22 / 441.58 6 6
5 486.72 31 13.44 1180 492 4.71 / 442.07 6 6
6 0.08 181 14.11 359 917 5.63 / 442.99 6 19
Average= 4.82 (KJ/cycle)

Cycle 90 GMT 4/12/2015 18: 8: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.72 30 14.12 538 228 0.23 / 431.97 6 6
2 2001.56 56 9.73 3479 1896 2.12 / 433.86 6 6
3 1839.64 31 11.75 3300 1202 3.33 / 435.07 6 6
4 1254.32 30 12.44 2433 908 4.23 / 435.97 6 6
5 448.72 31 13.52 1122 470 4.70 / 436.44 6 6
6 0.20 181 14.09 361 921 5.62 / 437.36 6 20
Average= 4.81 (KJ/cycle)

Cycle 89 GMT 24/11/2015 18: 6: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.12 30 14.12 557 236 0.24 / 426.49 6 6
2 2001.56 46 9.65 3436 1525 1.76 / 428.01 6 6
3 1850.48 31 11.72 3336 1212 2.97 / 429.23 6 6
4 1318.84 31 12.42 2536 976 3.95 / 430.20 6 6
5 720.80 31 13.11 1569 638 4.59 / 430.84 6 6
6 0.16 181 14.09 353 900 5.49 / 431.74 6 21
Average= 4.80 (KJ/cycle)

Cycle 88 GMT 14/11/2015 17:50: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.28 30 14.06 576 243 0.24 / 420.75 6 6
2 2004.28 46 9.78 3455 1554 1.80 / 422.31 6 6
3 1860.04 31 11.78 3284 1199 3.00 / 423.51 6 6
4 1484.04 31 12.20 2770 1048 4.04 / 424.55 6 6
5 672.44 31 13.21 1494 612 4.66 / 425.17 6 6
6 46.36 31 14.15 440 193 4.85 / 425.36 6 7
7 0.04 181 14.13 349 893 5.74 / 426.25 6 23
Average= 4.79 (KJ/cycle)

Cycle 87 GMT 4/11/2015 17:53: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.24 30 14.00 557 234 0.23 / 415.36 6 6
2 1113.52 3 7.50 2144 48 0.28 / 415.41 6 6
3 2002.64 45 9.89 3601 1603 1.88 / 417.01 6 6
4 1849.64 30 11.77 3288 1161 3.05 / 418.17 6 6
5 1281.00 30 12.47 2443 914 3.96 / 419.08 6 6
6 485.32 30 13.47 1182 478 4.44 / 419.56 6 6
7 0.16 180 14.04 376 950 5.39 / 420.51 6 22
Average= 4.78 (KJ/cycle)

Cycle 86 GMT 25/10/2015 17:30: 3

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.08 30 13.87 596 248 0.25 / 409.99 6 6
2 1108.60 3 7.69 2220 51 0.30 / 410.04 6 6
3 2002.92 45 10.16 3498 1599 1.90 / 411.64 6 6
4 1840.52 30 11.74 3300 1162 3.06 / 412.80 6 6
5 1255.36 30 12.47 2430 909 3.97 / 413.71 6 6
6 454.76 30 13.50 1132 458 4.43 / 414.17 6 7
7 0.00 181 14.02 375 952 5.38 / 415.12 6 23
Average= 4.77 (KJ/cycle)

Cycle 85 GMT 15/10/2015 17: 8: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.12 30 14.00 557 234 0.23 / 404.53 6 6
2 1103.00 3 7.66 2288 53 0.29 / 404.58 6 6
3 2001.72 45 10.12 3498 1593 1.88 / 406.17 6 6
4 1841.92 30 11.74 3275 1153 3.03 / 407.33 6 6
5 1443.00 30 12.22 2741 1005 4.04 / 408.33 6 6
6 440.84 30 13.52 1121 455 4.49 / 408.79 6 6
7 0.92 181 14.01 377 956 5.45 / 409.74 6 23
Average= 4.76 (KJ/cycle)

Cycle 84 GMT 5/10/2015 16:35:59

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.72 30 14.00 576 242 0.24 / 399.17 6 6
2 1113.52 3 8.47 2249 57 0.30 / 399.23 6 6
3 1996.12 46 10.17 3516 1645 1.94 / 400.87 6 6
4 1835.64 30 11.67 3363 1177 3.12 / 402.05 6 6
5 1253.04 30 12.43 2438 909 4.03 / 402.96 6 6
6 311.08 30 13.67 906 372 4.40 / 403.33 6 6
7 0.12 181 14.01 380 964 5.37 / 404.29 6 24
Average= 4.76 (KJ/cycle)

Cycle 83 GMT 25/ 9/2015 15:15: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.40 30 14.06 557 235 0.23 / 393.77 6 6
2 1108.04 3 8.31 2191 55 0.29 / 393.82 6 6
3 1997.32 45 10.15 3538 1616 1.91 / 395.44 6 6
4 1822.00 30 11.72 3286 1155 3.06 / 396.59 6 6
5 1259.52 30 12.37 2478 920 3.98 / 397.51 6 6
6 455.52 30 13.45 1155 466 4.45 / 397.98 6 7
7 0.28 181 13.99 376 952 5.40 / 398.93 6 22
Average= 4.75 (KJ/cycle)

Cycle 82 GMT 15/ 9/2015 14: 9: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.56 30 14.06 557 235 0.23 / 388.38 6 6
2 1115.44 3 8.22 2201 54 0.29 / 388.43 6 6
3 2001.48 45 10.09 3566 1619 1.91 / 390.05 6 6
4 1837.08 30 11.70 3358 1179 3.09 / 391.23 6 6
5 1255.88 30 12.44 2433 908 4.00 / 392.14 6 6
6 471.68 30 13.43 1179 475 4.47 / 392.61 6 6
7 0.04 181 14.02 362 919 5.39 / 393.53 6 27
Average= 4.74 (KJ/cycle)

Cycle 81 GMT 5/ 9/2015 13:14: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.08 30 14.00 576 242 0.24 / 382.82 6 6
2 1125.08 3 8.34 2163 54 0.30 / 382.88 6 6
3 2004.60 46 10.16 3504 1638 1.93 / 384.51 6 6
4 1845.92 30 11.73 3333 1173 3.11 / 385.69 6 6
5 1255.16 30 12.46 2429 908 4.01 / 386.60 6 6
6 449.36 30 13.47 1138 460 4.47 / 387.05 6 6
7 1.68 30 14.21 371 158 4.63 / 387.21 6 10
8 0.00 180 13.98 369 929 5.56 / 388.14 6 27
Average= 4.73 (KJ/cycle)

Cycle 80 GMT 26/ 8/2015 11:58: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.52 30 14.06 557 235 0.23 / 377.46 6 6
2 1108.72 3 8.10 2115 51 0.29 / 377.51 6 6
3 1995.36 45 10.23 3482 1603 1.89 / 379.11 6 6
4 1831.20 30 11.72 3307 1163 3.05 / 380.28 6 6
5 1247.12 30 12.48 2400 899 3.95 / 381.17 6 6
6 440.36 30 13.47 1119 452 4.40 / 381.63 6 6
7 0.40 180 13.98 379 954 5.36 / 382.58 6 30
Average= 4.72 (KJ/cycle)

Cycle 79 GMT 16/ 8/2015 11: 5: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.20 30 14.06 576 243 0.24 / 372.40 6 6
2 1112.60 5 9.42 2102 99 0.34 / 372.50 6 6
3 1962.84 34 10.49 3485 1243 1.58 / 373.75 6 6
4 1809.52 25 11.90 3220 958 2.54 / 374.70 6 6
5 1437.88 25 12.36 2720 840 3.38 / 375.55 6 6
6 698.64 25 13.21 1530 505 3.89 / 376.05 6 6
7 37.48 26 14.12 433 159 4.05 / 376.21 6 6
8 0.08 191 13.98 380 1015 5.06 / 377.22 6 28
Average= 4.72 (KJ/cycle)

Cycle 78 GMT 6/ 8/2015 9:54: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.44 30 14.06 576 243 0.24 / 367.16 6 6
2 1121.04 5 9.31 2115 98 0.34 / 367.26 6 6
3 1967.64 34 10.63 3478 1257 1.60 / 368.51 6 6
4 1820.12 25 11.84 3314 981 2.58 / 369.50 6 6
5 1452.88 25 12.35 2722 840 3.42 / 370.34 6 6
6 856.68 25 12.99 1803 586 4.01 / 370.92 6 6
7 118.36 26 13.98 586 213 4.22 / 371.13 6 7
8 0.04 191 13.97 385 1027 5.25 / 372.16 6 25
Average= 4.71 (KJ/cycle)

Cycle 77 GMT 27/ 7/2015 8:50: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.68 30 14.06 557 235 0.23 / 361.84 6 6
2 1226.56 5 9.29 2217 103 0.34 / 361.94 6 6
3 2002.96 34 10.70 3493 1271 1.61 / 363.21 6 6
4 1860.52 25 11.87 3324 986 2.60 / 364.20 6 6
5 1498.52 25 12.35 2782 859 3.45 / 365.06 6 6
6 913.96 25 12.94 1899 614 4.07 / 365.67 6 6
7 155.32 26 13.90 642 232 4.30 / 365.90 6 6
8 0.12 191 13.97 379 1011 5.31 / 366.92 6 23
Average= 4.70 (KJ/cycle)

Cycle 76 GMT 17/ 7/2015 7:40: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.48 30 14.00 596 250 0.25 / 356.58 6 6
2 1100.16 5 9.25 2108 97 0.35 / 356.68 6 6
3 1979.12 34 10.47 3513 1251 1.60 / 357.93 6 6
4 1830.12 25 11.88 3318 985 2.58 / 358.91 6 6
5 1466.20 25 12.36 2766 855 3.44 / 359.77 6 6
6 878.64 25 12.97 1839 596 4.03 / 360.37 6 6
7 123.76 25 13.99 605 212 4.25 / 360.58 6 6
8 0.04 191 13.97 385 1027 5.27 / 361.60 6 25
Average= 4.70 (KJ/cycle)

Cycle 75 GMT 7/ 7/2015 6:37: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.08 30 14.00 596 250 0.25 / 351.33 6 6
2 1118.68 5 9.17 2076 95 0.35 / 351.42 6 6
3 1973.12 34 10.59 3463 1247 1.59 / 352.67 6 6
4 1824.92 25 11.94 3272 977 2.57 / 353.64 6 6
5 1466.52 25 12.33 2767 853 3.42 / 354.50 6 6
6 892.32 25 12.94 1884 609 4.03 / 355.11 6 6
7 72.68 25 14.04 520 183 4.21 / 355.29 6 6
8 -0.08 191 13.98 390 1041 5.26 / 356.33 6 23
Average= 4.69 (KJ/cycle)

Cycle 74 GMT 27/ 6/2015 5:27: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.48 30 14.12 576 244 0.24 / 346.17 6 6
2 1114.04 5 9.17 2070 95 0.34 / 346.27 6 6
3 1980.64 34 10.63 3467 1253 1.59 / 347.52 6 6
4 1830.76 25 11.95 3259 974 2.57 / 348.50 6 6
5 1489.20 25 12.33 2803 864 3.43 / 349.36 6 6
6 737.36 25 13.16 1612 530 3.96 / 349.89 6 6
7 23.64 26 14.16 419 154 4.11 / 350.04 6 6
8 0.12 191 13.99 386 1031 5.15 / 351.08 6 27
Average= 4.68 (KJ/cycle)

Cycle 73 GMT 17/ 6/2015 4: 5: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.76 30 14.12 557 236 0.24 / 340.79 6 6
2 1106.76 5 9.08 2083 95 0.33 / 340.89 6 6
3 1963.48 34 10.60 3478 1253 1.58 / 342.14 6 6
4 1821.84 25 11.96 3307 989 2.57 / 343.13 6 6
5 1466.52 25 12.33 2784 858 3.43 / 343.99 6 6
6 887.64 25 12.99 1845 599 4.03 / 344.59 6 6
7 136.16 26 13.95 621 225 4.26 / 344.81 6 7
8 5.20 26 14.22 375 139 4.39 / 344.95 6 8
9 0.00 191 13.95 367 978 5.37 / 345.93 6 29
Average= 4.67 (KJ/cycle)

Cycle 72 GMT 7/ 6/2015 2:56: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.96 30 14.12 557 236 0.24 / 335.44 6 6
2 1217.60 5 8.77 2179 96 0.33 / 335.53 6 6
3 2001.44 34 10.62 3516 1270 1.60 / 336.80 6 6
4 1857.84 25 11.89 3370 1002 2.60 / 337.80 6 6
5 1505.92 25 12.34 2822 871 3.47 / 338.67 6 6
6 933.64 25 12.91 1957 632 4.10 / 339.31 6 6
7 161.44 26 13.90 685 248 4.35 / 339.55 6 6
8 0.08 190 13.98 378 1004 5.36 / 340.56 6 22
Average= 4.67 (KJ/cycle)

Cycle 71 GMT 28/ 5/2015 2: 1: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.88 29 14.06 596 243 0.24 / 330.14 6 6
2 1131.68 5 8.98 2082 93 0.34 / 330.23 6 6
3 1973.48 34 10.55 3491 1252 1.59 / 331.48 6 6
4 1841.08 25 11.85 3378 1001 2.59 / 332.48 6 6
5 1455.36 25 12.39 2768 857 3.45 / 333.34 6 6
6 881.96 25 13.00 1868 607 4.05 / 333.95 6 6
7 153.84 26 13.94 653 237 4.29 / 334.19 6 6
8 0.00 191 14.00 380 1016 5.31 / 335.20 6 22
Average= 4.66 (KJ/cycle)

Cycle 70 GMT 18/ 5/2015 0:53: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.60 29 14.12 576 236 0.24 / 324.73 6 6
2 1223.36 5 8.73 2140 93 0.33 / 324.82 6 6
3 2001.92 34 10.57 3552 1277 1.61 / 326.10 6 6
4 1866.88 25 11.96 3357 1004 2.61 / 327.10 6 6
5 1505.88 25 12.36 2836 876 3.49 / 327.98 6 6
6 924.80 25 12.96 1939 628 4.11 / 328.61 6 6
7 162.88 25 13.89 678 235 4.35 / 328.84 6 6
8 0.28 191 13.99 393 1050 5.40 / 329.89 6 25
Average= 4.65 (KJ/cycle)

Cycle 69 GMT 7/ 5/2015 23:44: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.52 28 14.18 500 199 0.20 / 319.52 6 6
2 1026.12 1 10.88 2076 23 0.22 / 319.54 6 6
3 1134.64 5 8.44 2102 89 0.31 / 319.63 6 6
4 1982.76 34 10.47 3515 1251 1.56 / 320.88 6 6
5 1843.12 25 12.00 3349 1005 2.57 / 321.88 6 6
6 1479.64 25 12.39 2788 864 3.43 / 322.75 6 6
7 903.20 25 12.96 1884 610 4.04 / 323.36 6 6
8 141.56 26 13.95 615 223 4.26 / 323.58 6 6
9 -0.08 191 14.08 340 914 5.18 / 324.50 6 22
Average= 4.64 (KJ/cycle)

Cycle 68 GMT 27/ 4/2015 22:29: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.44 30 14.18 500 213 0.21 / 314.36 6 6
2 961.36 -1 14.18 500 0. 0.00 / 314.36 6 6
3 1163.40 3 6.50 1999 39 0.25 / 314.40 6 6
4 2002.60 34 10.35 3527 1241 1.49 / 315.64 6 6
5 1877.48 25 12.03 3357 1010 2.50 / 316.65 6 6
6 1526.88 25 12.37 2884 892 3.39 / 317.54 6 6
7 969.32 25 12.94 1966 636 4.03 / 318.18 6 6
8 187.64 25 13.93 678 236 4.27 / 318.41 6 6
9 -0.20 191 14.05 337 904 5.17 / 319.32 6 28
Average= 4.63 (KJ/cycle)

Cycle 67 GMT 17/ 4/2015 21:59: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.32 30 14.25 500 214 0.21 / 309.13 6 6
2 1157.72 3 4.91 2230 33 0.25 / 309.16 6 6
3 2003.20 34 10.25 3523 1228 1.47 / 310.39 6 6
4 1886.00 25 11.93 3420 1020 2.49 / 311.41 6 6
5 1536.36 25 12.36 2837 877 3.37 / 312.29 6 6
6 1138.44 25 12.77 2251 719 4.09 / 313.01 6 6
7 171.28 25 13.91 658 229 4.32 / 313.24 6 6
8 0.20 191 14.07 339 911 5.23 / 314.15 6 24
Average= 4.62 (KJ/cycle)

Cycle 66 GMT 7/ 4/2015 21:47: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.48 30 14.12 519 220 0.22 / 303.35 6 6
2 1166.52 2 4.88 1961 19 0.24 / 303.36 6 6
3 2001.08 36 9.91 3478 1241 1.48 / 304.61 6 6
4 1919.88 21 12.04 3448 872 2.35 / 305.48 6 6
5 1812.00 21 12.27 3251 838 3.19 / 306.31 6 6
6 1393.96 21 12.61 2621 694 3.88 / 307.01 6 6
7 1100.00 21 12.88 2204 596 4.48 / 307.61 6 6
8 349.92 21 13.67 967 278 4.76 / 307.88 6 6
9 30.56 21 14.18 411 122 4.88 / 308.01 6 7
10 -0.12 191 14.05 340 912 5.79 / 308.92 6 24
Average= 4.61 (KJ/cycle)

Cycle 65 GMT 28/ 3/2015 22:19: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.20 27 14.25 500 192 0.19 / 297.73 6 6
2 1011.88 4 13.25 1980 105 0.30 / 297.83 6 6
3 932.44 -1 13.25 1980 0. 0.10 / 297.83 6 6
4 1142.60 2 4.91 2076 20 0.32 / 297.85 6 6
5 2004.48 36 9.97 3518 1263 1.58 / 299.12 6 6
6 1920.64 21 12.08 3444 874 2.45 / 299.99 6 6
7 1819.68 21 12.25 3290 846 3.30 / 300.84 6 6
8 1395.48 21 12.64 2653 704 4.00 / 301.54 6 6
9 817.88 21 13.15 1719 475 4.48 / 302.02 6 6
10 249.24 21 13.84 779 226 4.71 / 302.24 6 6
11 0.12 191 14.09 328 883 5.59 / 303.13 6 26
Average= 4.59 (KJ/cycle)

Cycle 64 GMT 18/ 3/2015 22:29: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.12 29 14.25 500 207 0.21 / 292.55 6 6
2 1002.24 4 13.18 2038 107 0.31 / 292.66 6 6
3 874.56 -2 13.18 2038 0. 0.11 / 292.66 6 6
4 898.00 -2 13.18 2038 0. 0.11 / 292.66 6 6
5 1159.92 2 5.25 1990 21 0.33 / 292.68 6 6
6 1773.08 36 10.32 3187 1184 1.52 / 293.86 6 6
7 1708.56 21 12.21 3108 797 2.32 / 294.66 6 6
8 1590.76 21 12.43 2871 749 3.07 / 295.41 6 6
9 1204.80 21 12.75 2369 634 3.70 / 296.04 6 6
10 664.48 21 13.32 1473 412 4.11 / 296.45 6 6
11 105.84 21 14.03 554 163 4.27 / 296.62 6 6
12 -0.08 190 14.05 345 921 5.20 / 297.54 6 26
Average= 4.58 (KJ/cycle)

Cycle 63 GMT 8/ 3/2015 22:10: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.52 29 14.31 480 199 0.20 / 287.82 6 6
2 1181.16 2 4.88 1980 19 0.22 / 287.84 6 6
3 1587.68 36 10.39 2892 1082 1.30 / 288.92 6 6
4 1533.72 21 12.31 2865 741 2.04 / 289.66 6 6
5 1417.00 21 12.48 2677 702 2.74 / 290.36 6 6
6 1149.76 21 12.81 2228 599 3.34 / 290.96 6 6
7 441.72 21 13.57 1100 313 3.66 / 291.28 6 6
8 69.76 21 14.14 478 142 3.80 / 291.42 6 6
9 0.08 191 14.06 344 924 4.72 / 292.34 6 25
Average= 4.57 (KJ/cycle)

Cycle 62 GMT 26/ 2/2015 22:26: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.00 29 14.18 519 213 0.21 / 283.01 6 6
2 1157.84 2 4.91 2144 21 0.23 / 283.04 6 6
3 1480.04 36 10.76 2749 1065 1.30 / 284.10 6 6
4 1438.00 21 12.38 2698 701 2.00 / 284.80 6 6
5 1330.08 21 12.66 2508 667 2.67 / 285.47 6 6
6 1205.08 21 12.76 2335 626 3.29 / 286.09 6 6
7 626.36 21 13.32 1424 398 3.69 / 286.49 6 6
8 165.68 21 13.97 659 193 3.88 / 286.69 6 7
9 -0.04 191 14.06 348 935 4.82 / 287.62 6 26
Average= 4.57 (KJ/cycle)

Cycle 61 GMT 16/ 2/2015 23: 1: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.60 30 14.31 500 215 0.21 / 278.40 6 6
2 942.56 -1 14.31 500 0. 0.00 / 278.40 6 6
3 1163.32 2 5.32 2019 21 0.24 / 278.42 6 6
4 1392.12 36 10.81 2605 1014 1.25 / 279.44 6 6
5 1361.60 21 12.49 2553 670 1.92 / 280.10 6 6
6 1268.04 21 12.65 2414 641 2.56 / 280.75 6 6
7 1136.12 21 12.81 2215 596 3.16 / 281.34 6 6
8 674.88 21 13.31 1480 414 3.57 / 281.76 6 6
9 41.64 21 14.17 429 128 3.70 / 281.88 6 6
10 0.08 191 14.05 342 918 4.62 / 282.80 6 29
Average= 4.56 (KJ/cycle)

Cycle 60 GMT 6/ 2/2015 23:45: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.64 30 14.25 500 214 0.21 / 273.80 6 6
2 1152.76 2 6.16 1980 24 0.24 / 273.83 6 6
3 1385.28 36 10.80 2626 1021 1.26 / 274.85 6 6
4 1351.64 21 12.45 2580 675 1.93 / 275.52 6 6
5 1260.32 21 12.69 2405 641 2.57 / 276.17 6 6
6 1139.60 21 12.80 2247 604 3.18 / 276.77 6 6
7 535.00 21 13.46 1275 360 3.54 / 277.13 6 6
8 53.80 21 14.18 458 136 3.68 / 277.27 6 6
9 0.24 191 14.11 341 919 4.59 / 278.19 6 30
Average= 4.56 (KJ/cycle)

Cycle 59 GMT 28/ 1/2015 0:29: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.44 29 14.31 519 215 0.22 / 269.29 6 6
2 1020.40 1 10.57 1980 21 0.24 / 269.31 6 6
3 1108.52 2 6.69 1999 27 0.26 / 269.34 6 6
4 1385.64 36 10.93 2615 1029 1.29 / 270.37 6 6
5 1346.00 21 12.50 2548 669 1.96 / 271.04 6 6
6 1239.96 21 12.71 2384 636 2.60 / 271.67 6 6
7 1109.96 21 12.87 2181 589 3.19 / 272.26 6 6
8 401.28 21 13.67 1048 301 3.49 / 272.57 6 6
9 43.88 21 14.24 429 128 3.62 / 272.69 6 6
10 0.56 191 14.11 333 897 4.51 / 273.59 6 25
Average= 4.56 (KJ/cycle)

Cycle 58 GMT 18/ 1/2015 1: 6: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.88 29 14.31 500 207 0.21 / 264.18 6 6
2 1183.96 2 7.13 2163 31 0.24 / 264.21 6 6
3 1719.12 36 10.63 3117 1193 1.43 / 265.40 6 6
4 1646.40 21 12.26 2999 772 2.20 / 266.18 6 6
5 1534.88 21 12.49 2839 745 2.95 / 266.92 6 6
6 1273.20 21 12.77 2446 656 3.60 / 267.58 6 6
7 834.60 21 13.15 1762 487 4.09 / 268.06 6 6
8 100.24 21 14.15 521 155 4.25 / 268.22 6 6
9 -0.08 190 14.15 320 860 5.11 / 269.08 6 24
Average= 4.56 (KJ/cycle)

Cycle 57 GMT 8/ 1/2015 1: 7: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.48 29 14.25 519 214 0.21 / 259.33 6 6
2 1174.48 2 7.62 2192 33 0.25 / 259.36 6 6
3 1639.16 36 10.84 2955 1153 1.40 / 260.52 6 6
4 1568.20 21 12.34 2943 763 2.16 / 261.28 6 6
5 1451.12 21 12.53 2721 716 2.88 / 262.00 6 6
6 1183.52 21 12.83 2320 625 3.50 / 262.62 6 6
7 488.64 21 13.60 1185 338 3.84 / 262.96 6 6
8 42.68 21 14.28 416 125 3.97 / 263.08 6 6
9 0.12 190 14.12 331 888 4.86 / 263.97 6 25
Average= 4.55 (KJ/cycle)

Cycle 56 GMT 29/12/2014 1:14:58

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.36 29 14.31 500 207 0.21 / 253.90 6 6
2 1102.72 2 8.72 2115 37 0.24 / 253.94 6 6
3 1967.96 36 10.52 3487 1321 1.56 / 255.26 6 6
4 1870.96 21 12.17 3362 859 2.42 / 256.12 6 6
5 1740.24 21 12.34 3138 813 3.24 / 256.93 6 6
6 1187.44 21 12.87 2332 630 3.87 / 257.56 6 6
7 899.24 21 13.13 1888 521 4.39 / 258.09 6 6
8 65.72 21 14.15 469 139 4.53 / 258.22 6 6
9 0.16 190 14.13 332 891 5.42 / 259.12 6 22
Average= 4.55 (KJ/cycle)

Cycle 55 GMT 19/12/2014 0:44: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.28 29 14.25 500 207 0.21 / 248.34 6 6
2 1172.48 2 9.81 2393 47 0.25 / 248.39 6 6
3 2004.56 36 10.55 3585 1362 1.62 / 249.75 6 6
4 1909.52 21 12.16 3373 861 2.48 / 250.61 6 6
5 1778.24 21 12.31 3200 827 3.30 / 251.44 6 6
6 1360.12 21 12.73 2612 698 4.00 / 252.14 6 6
7 774.96 21 13.25 1657 461 4.46 / 252.60 6 6
8 190.60 21 14.00 681 200 4.66 / 252.80 6 6
9 -0.08 191 14.12 334 901 5.56 / 253.70 6 25
Average= 4.53 (KJ/cycle)

Cycle 54 GMT 9/12/2014 0:30: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.64 29 14.25 519 214 0.21 / 242.71 6 6
2 1164.24 2 10.87 2268 49 0.26 / 242.75 6 6
3 2000.48 36 10.92 3526 1386 1.65 / 244.14 6 6
4 1927.00 21 12.20 3424 877 2.53 / 245.02 6 6
5 1795.52 21 12.35 3268 848 3.37 / 245.87 6 6
6 1513.68 21 12.64 2777 737 4.11 / 246.60 6 6
7 761.44 21 13.25 1653 460 4.57 / 247.06 6 6
8 78.80 21 14.13 504 150 4.72 / 247.21 6 6
9 0.00 191 14.10 342 921 5.64 / 248.13 6 24
Average= 4.51 (KJ/cycle)

Cycle 53 GMT 29/11/2014 0:43: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.08 29 14.31 500 207 0.21 / 237.34 6 6
2 1103.80 2 11.07 2173 48 0.26 / 237.39 6 6
3 2002.68 36 10.87 3526 1380 1.64 / 238.77 6 6
4 1901.48 21 12.20 3386 867 2.50 / 239.64 6 6
5 1774.92 21 12.33 3230 836 3.34 / 240.47 6 6
6 1216.08 21 12.91 2349 637 3.98 / 241.11 6 6
7 546.44 21 13.55 1288 367 4.34 / 241.48 6 6
8 51.64 21 14.25 435 130 4.47 / 241.61 6 6
9 0.08 191 14.15 327 884 5.36 / 242.49 6 22
Average= 4.49 (KJ/cycle)

Cycle 52 GMT 19/11/2014 0:13: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.20 29 14.31 500 207 0.21 / 232.68 6 6
2 1169.80 2 11.75 2250 53 0.26 / 232.73 6 6
3 1532.00 36 11.52 2809 1165 1.43 / 233.89 6 6
4 1468.40 21 12.53 2743 722 2.15 / 234.62 6 6
5 1361.84 21 12.69 2584 689 2.84 / 235.30 6 6
6 957.92 21 13.10 1937 533 3.37 / 235.84 6 6
7 396.96 21 13.74 1038 300 3.67 / 236.14 6 6
8 3.00 21 14.31 348 105 3.77 / 236.24 6 6
9 0.08 191 14.08 332 893 4.67 / 237.13 6 28
Average= 4.47 (KJ/cycle)

Cycle 51 GMT 9/11/2014 0:34: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.24 29 14.25 519 214 0.21 / 228.38 6 6
2 1108.96 2 12.18 2173 53 0.27 / 228.43 6 6
3 1358.00 36 11.81 2538 1079 1.35 / 229.51 6 6
4 1301.12 21 12.67 2480 660 2.01 / 230.17 6 6
5 1195.52 21 12.86 2307 623 2.63 / 230.80 6 6
6 793.00 21 13.29 1683 470 3.10 / 231.27 6 6
7 360.48 21 13.78 976 282 3.38 / 231.55 6 7
8 0.12 191 14.10 342 921 4.30 / 232.47 6 24
Average= 4.47 (KJ/cycle)

Cycle 50 GMT 30/10/2014 1:23:59

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.84 29 14.25 519 214 0.21 / 223.92 6 6
2 1161.36 2 12.06 2307 56 0.27 / 223.98 6 6
3 1440.28 36 11.82 2665 1134 1.40 / 225.11 6 6
4 1379.44 21 12.67 2593 690 2.09 / 225.80 6 6
5 1269.92 21 12.80 2420 650 2.74 / 226.45 6 6
6 868.32 21 13.23 1796 499 3.24 / 226.95 6 6
7 438.76 21 13.71 1093 315 3.56 / 227.27 6 6
8 0.04 191 14.11 334 900 4.46 / 228.17 6 26
Average= 4.47 (KJ/cycle)

Cycle 49 GMT 20/10/2014 2: 3: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.24 29 14.31 519 215 0.22 / 219.62 6 6
2 1169.52 2 12.31 2269 56 0.27 / 219.68 6 6
3 1355.04 36 11.90 2559 1096 1.37 / 220.78 6 6
4 1301.76 21 12.71 2486 664 2.03 / 221.44 6 6
5 1195.84 21 12.86 2341 632 2.66 / 222.07 6 6
6 815.76 21 13.31 1717 480 3.14 / 222.55 6 6
7 237.96 21 13.98 775 228 3.37 / 222.78 6 6
8 0.16 191 14.12 344 928 4.30 / 223.71 6 21
Average= 4.47 (KJ/cycle)

Cycle 48 GMT 10/10/2014 2:52: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.68 29 14.25 519 214 0.21 / 215.57 6 6
2 1169.92 2 12.56 2326 58 0.27 / 215.63 6 6
3 1185.04 5 12.43 2320 144 0.42 / 215.78 6 6
4 1185.00 50 12.09 2282 1379 1.80 / 217.16 6 6
5 1081.36 21 12.97 2142 583 2.38 / 217.74 6 6
6 949.84 21 13.16 1929 533 2.91 / 218.27 6 6
7 202.40 21 14.03 715 211 3.12 / 218.48 6 6
8 0.04 191 14.10 344 926 4.05 / 219.41 6 19
Average= 4.48 (KJ/cycle)

Cycle 47 GMT 30/ 9/2014 4:14:58

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.20 29 14.18 519 213 0.21 / 209.99 6 6
2 1169.96 2 12.68 2250 57 0.27 / 210.05 6 6
3 2000.24 5 12.02 3602 216 0.49 / 210.27 6 6
4 2000.48 50 11.40 3526 2010 2.50 / 212.28 6 6
5 1746.52 21 12.48 3185 835 3.33 / 213.11 6 6
6 1325.24 21 12.89 2529 685 4.02 / 213.80 6 6
7 876.76 20 13.27 1848 490 4.51 / 214.29 6 6
8 65.16 21 14.21 475 142 4.65 / 214.43 6 6
9 0.08 191 14.11 345 930 5.58 / 215.36 6 24
Average= 4.49 (KJ/cycle)

Cycle 46 GMT 20/ 9/2014 4:26:58

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.28 29 14.31 538 223 0.22 / 204.59 6 6
2 1185.28 2 12.81 2269 58 0.28 / 204.65 6 6
3 2002.16 5 12.29 3538 217 0.50 / 204.87 6 6
4 2002.32 50 11.47 3544 2032 2.53 / 206.90 6 6
5 1746.52 21 12.53 3129 823 3.35 / 207.72 6 6
6 1198.68 20 13.00 2331 606 3.96 / 208.33 6 6
7 647.68 20 13.52 1449 392 4.35 / 208.72 6 6
8 105.16 20 14.19 535 152 4.50 / 208.87 6 6
9 0.00 191 14.13 336 907 5.41 / 209.78 6 25
Average= 4.46 (KJ/cycle)

Cycle 45 GMT 10/ 9/2014 4:30: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.76 28 14.37 500 201 0.20 / 199.18 6 6
2 1176.92 3 12.62 2298 87 0.29 / 199.26 6 6
3 1990.00 50 11.31 3551 2008 2.30 / 201.27 6 6
4 1723.48 21 12.52 3161 831 3.13 / 202.10 6 6
5 1325.72 21 12.82 2563 690 3.82 / 202.79 6 6
6 780.76 21 13.36 1651 463 4.28 / 203.26 6 6
7 200.92 21 14.05 704 208 4.49 / 203.46 6 7
8 0.12 191 14.16 335 906 5.39 / 204.37 6 21
Average= 4.44 (KJ/cycle)

Cycle 44 GMT 31/ 8/2014 3:57: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.68 28 14.37 519 209 0.21 / 193.77 6 6
2 1184.64 3 12.75 2307 88 0.30 / 193.86 6 6
3 1965.40 50 11.34 3510 1990 2.29 / 195.85 6 6
4 1835.72 21 12.29 3392 875 3.16 / 196.73 6 6
5 1281.56 21 12.89 2473 669 3.83 / 197.39 6 6
6 863.52 21 13.28 1817 507 4.34 / 197.90 6 7
7 125.80 21 14.15 580 172 4.51 / 198.07 6 6
8 0.00 191 14.14 334 902 5.41 / 198.98 6 20
Average= 4.42 (KJ/cycle)

Cycle 43 GMT 21/ 8/2014 3:34: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.48 28 14.31 519 208 0.21 / 189.32 6 6
2 1116.64 2 12.43 2269 56 0.26 / 189.38 6 6
3 1512.80 50 11.89 2798 1663 1.93 / 191.04 6 6
4 1394.92 21 12.68 2653 706 2.63 / 191.75 6 6
5 1130.36 21 13.01 2236 611 3.25 / 192.36 6 6
6 396.96 21 13.77 1038 300 3.55 / 192.66 6 6
7 0.12 191 14.15 334 903 4.45 / 193.56 6 22
Average= 4.40 (KJ/cycle)

Cycle 42 GMT 11/ 8/2014 7:18: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.48 28 14.31 538 216 0.22 / 184.78 6 6
2 1108.12 1 12.43 2192 27 0.24 / 184.81 6 6
3 1515.48 50 11.88 2822 1676 1.92 / 186.49 6 6
4 1414.08 21 12.68 2685 715 2.63 / 187.20 6 6
5 1150.68 21 12.96 2277 620 3.25 / 187.82 6 6
6 580.72 21 13.54 1352 384 3.64 / 188.21 6 6
7 0.04 191 14.13 337 910 4.55 / 189.11 6 22
Average= 4.40 (KJ/cycle)

Cycle 41 GMT 1/ 8/2014 11: 2: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.32 28 14.25 519 207 0.21 / 180.41 6 6
2 1107.72 1 12.06 2288 28 0.23 / 180.44 6 6
3 1501.44 50 11.97 2793 1672 1.91 / 182.11 6 6
4 1391.52 21 12.74 2601 696 2.60 / 182.81 6 6
5 985.28 21 13.15 2008 555 3.16 / 183.36 6 6
6 408.80 21 13.71 1076 310 3.47 / 183.67 6 6
7 0.16 191 14.13 331 893 4.36 / 184.57 6 23
Average= 4.39 (KJ/cycle)

Cycle 40 GMT 22/ 7/2014 14:59: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.24 28 14.37 519 209 0.21 / 176.01 6 6
2 1107.84 1 12.31 2192 27 0.24 / 176.04 6 6
3 1502.92 50 12.02 2780 1671 1.91 / 177.71 6 6
4 1390.72 21 12.74 2632 704 2.61 / 178.41 6 6
5 1112.60 21 13.01 2228 609 3.22 / 179.02 6 6
6 390.96 21 13.78 1040 301 3.52 / 179.32 6 6
7 0.12 191 14.15 328 886 4.41 / 180.21 6 23
Average= 4.40 (KJ/cycle)

Cycle 39 GMT 12/ 7/2014 18:56: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.44 28 14.25 519 207 0.21 / 171.54 6 6
2 1106.24 1 12.37 2211 27 0.23 / 171.57 6 6
3 1505.92 50 12.04 2788 1678 1.91 / 173.25 6 6
4 1401.56 21 12.75 2623 702 2.62 / 173.95 6 6
5 1118.40 21 13.03 2217 607 3.22 / 174.55 6 6
6 267.32 21 13.99 826 243 3.46 / 174.80 6 6
7 8.20 21 14.39 354 107 3.57 / 174.90 6 7
8 0.04 191 14.13 332 896 4.47 / 175.80 6 29
Average= 4.40 (KJ/cycle)

Cycle 38 GMT 2/ 7/2014 22:45: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.72 28 14.25 519 207 0.21 / 167.07 6 6
2 1021.00 1 13.56 2057 28 0.23 / 167.10 6 6
3 1118.48 1 12.50 2230 28 0.26 / 167.13 6 6
4 1503.80 50 12.17 2803 1706 1.97 / 168.83 6 6
5 1386.44 21 12.78 2600 698 2.67 / 169.53 6 6
6 986.96 21 13.17 2001 553 3.22 / 170.08 6 6
7 289.40 21 13.98 862 253 3.47 / 170.34 6 6
8 11.16 21 14.40 365 110 3.58 / 170.45 6 7
9 0.04 191 14.14 328 886 4.47 / 171.33 6 25
Average= 4.39 (KJ/cycle)

Cycle 37 GMT 23/ 6/2014 2:32: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.36 28 14.43 500 202 0.20 / 162.42 6 6
2 1132.64 1 12.75 2269 29 0.23 / 162.45 6 6
3 1513.40 50 12.28 2801 1720 1.95 / 164.17 6 6
4 1392.84 21 12.81 2631 708 2.66 / 164.88 6 6
5 1118.12 21 13.11 2217 610 3.27 / 165.49 6 6
6 532.40 21 13.68 1268 364 3.63 / 165.85 6 6
7 18.24 21 14.39 375 113 3.75 / 165.96 6 6
8 0.88 190 14.11 336 901 4.65 / 166.86 6 23
Average= 4.39 (KJ/cycle)

Cycle 36 GMT 13/ 6/2014 6:24: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.88 28 14.37 480 193 0.19 / 158.09 6 6
2 1109.48 15 13.08 2185 429 0.62 / 158.52 6 6
3 1502.00 50 12.48 2787 1739 2.36 / 160.26 6 6
4 1088.64 21 13.12 2142 590 2.95 / 160.85 6 6
5 542.96 21 13.67 1266 363 3.31 / 161.21 6 6
6 20.16 21 14.38 371 112 3.43 / 161.32 6 6
7 0.04 191 14.16 331 895 4.32 / 162.22 6 23
Average= 4.38 (KJ/cycle)

Cycle 35 GMT 3/ 6/2014 9: 7: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.80 28 14.37 519 209 0.21 / 153.65 6 6
2 1118.64 15 13.06 2207 432 0.64 / 154.08 6 6
3 1502.76 50 12.52 2776 1738 2.38 / 155.82 6 6
4 1099.40 21 13.10 2176 599 2.98 / 156.42 6 6
5 675.36 21 13.58 1499 427 3.41 / 156.85 6 7
6 90.96 21 14.28 516 155 3.56 / 157.00 6 6
7 0.04 191 14.19 330 894 4.45 / 157.89 6 23
Average= 4.39 (KJ/cycle)

Cycle 34 GMT 24/ 5/2014 12:14: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.88 27 14.43 500 195 0.19 / 149.49 6 6
2 1118.64 15 13.01 2204 430 0.62 / 149.92 6 6
3 1278.80 50 12.76 2439 1556 2.18 / 151.48 6 6
4 1161.12 21 13.10 2266 623 2.80 / 152.10 6 6
5 433.60 21 13.82 1102 320 3.12 / 152.42 6 6
6 27.16 21 14.40 394 119 3.24 / 152.54 6 6
7 0.04 191 14.16 332 898 4.14 / 153.44 6 25
Average= 4.38 (KJ/cycle)

Cycle 33 GMT 14/ 5/2014 13:21: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.08 27 14.43 500 195 0.19 / 144.98 6 6
2 1107.64 15 13.12 2172 427 0.62 / 145.40 6 6
3 1501.40 50 12.55 2780 1744 2.37 / 147.15 6 6
4 1226.20 21 13.09 2382 655 3.02 / 147.80 6 6
5 658.56 21 13.57 1482 422 3.44 / 148.23 6 6
6 85.56 21 14.35 506 152 3.60 / 148.38 6 6
7 0.12 191 14.18 340 921 4.52 / 149.30 6 26
Average= 4.39 (KJ/cycle)

Cycle 32 GMT 4/ 5/2014 16:43: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.84 27 14.43 500 195 0.19 / 140.49 6 6
2 1128.92 15 13.18 2214 438 0.63 / 140.93 6 6
3 1502.44 50 12.60 2780 1751 2.38 / 142.68 6 6
4 1226.08 21 13.13 2360 651 3.03 / 143.33 6 6
5 636.20 21 13.62 1433 410 3.44 / 143.74 6 6
6 38.52 21 14.40 420 127 3.57 / 143.87 6 6
7 0.00 191 14.16 337 911 4.48 / 144.78 6 22
Average= 4.39 (KJ/cycle)

Cycle 31 GMT 24/ 4/2014 20: 3: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.92 27 14.43 519 202 0.20 / 135.94 6 6
2 1108.56 15 13.17 2195 434 0.64 / 136.37 6 6
3 1502.60 50 12.59 2786 1754 2.39 / 138.12 6 6
4 1233.40 21 13.08 2414 663 3.05 / 138.79 6 6
5 654.28 21 13.58 1482 423 3.48 / 139.21 6 6
6 81.12 21 14.29 510 153 3.63 / 139.36 6 6
7 0.12 191 14.16 346 936 4.56 / 140.30 6 24
Average= 4.38 (KJ/cycle)

Cycle 30 GMT 14/ 4/2014 23:17: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.36 27 14.43 519 202 0.20 / 131.36 6 6
2 1102.76 15 13.26 2185 435 0.64 / 131.79 6 6
3 1503.64 50 12.62 2787 1759 2.40 / 133.55 6 6
4 1372.28 21 12.98 2591 706 3.10 / 134.26 6 6
5 615.20 21 13.68 1392 400 3.50 / 134.66 6 6
6 73.96 21 14.35 491 148 3.65 / 134.81 6 6
7 0.00 191 14.17 343 928 4.58 / 135.74 6 24
Average= 4.38 (KJ/cycle)

Cycle 29 GMT 5/ 4/2014 2:28: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.68 27 14.43 500 195 0.19 / 126.90 6 6
2 1123.16 15 13.28 2230 444 0.64 / 127.34 6 6
3 1506.12 50 12.64 2817 1780 2.42 / 129.13 6 6
4 1374.36 21 12.99 2599 709 3.13 / 129.83 6 7
5 320.40 21 14.01 920 271 3.40 / 130.10 6 6
6 73.32 21 14.35 491 148 3.55 / 130.25 6 7
7 0.00 191 14.18 334 905 4.45 / 131.16 6 25
Average= 4.37 (KJ/cycle)

Cycle 28 GMT 26/ 3/2014 5:21: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.08 27 14.37 538 209 0.21 / 122.55 6 6
2 1102.00 15 13.34 2185 437 0.65 / 122.99 6 6
3 1511.24 50 12.69 2778 1763 2.41 / 124.75 6 6
4 1113.60 21 13.24 2187 608 3.02 / 125.36 6 6
5 389.60 21 13.94 1033 302 3.32 / 125.66 6 6
6 43.96 21 14.39 431 130 3.45 / 125.79 6 7
7 0.08 191 14.16 337 911 4.36 / 126.71 6 24
Average= 4.37 (KJ/cycle)

Cycle 27 GMT 16/ 3/2014 8:18: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.76 27 14.43 519 202 0.20 / 118.07 6 6
2 1120.92 15 13.45 2214 447 0.65 / 118.52 6 6
3 1501.64 50 12.72 2801 1781 2.43 / 120.30 6 6
4 1220.48 21 13.14 2367 653 3.08 / 120.95 6 6
5 509.88 21 13.82 1247 362 3.45 / 121.32 6 6
6 37.92 21 14.43 420 127 3.57 / 121.44 6 6
7 0.04 191 14.18 333 902 4.47 / 122.35 6 24
Average= 4.37 (KJ/cycle)

Cycle 26 GMT 6/ 3/2014 11:32: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.12 27 14.43 500 195 0.19 / 113.43 6 6
2 1114.80 15 13.49 2205 446 0.64 / 113.88 6 6
3 1500.76 50 12.74 2780 1771 2.41 / 115.65 6 6
4 1227.16 21 13.13 2398 661 3.07 / 116.31 6 6
5 793.04 21 13.53 1702 484 3.56 / 116.80 6 7
6 70.36 21 14.38 475 143 3.70 / 116.94 6 6
7 0.16 191 14.18 344 932 4.63 / 117.87 6 27
Average= 4.37 (KJ/cycle)

Cycle 25 GMT 24/ 2/2014 14:48: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.32 27 14.43 519 202 0.20 / 108.96 6 6
2 1117.56 15 13.52 2233 453 0.66 / 109.41 6 6
3 1503.00 50 12.74 2806 1787 2.44 / 111.20 6 6
4 1097.84 21 13.27 2185 609 3.05 / 111.81 6 6
5 530.92 21 13.78 1271 368 3.42 / 112.17 6 6
6 41.64 21 14.40 442 134 3.55 / 112.31 6 7
7 0.12 191 14.16 344 930 4.48 / 113.24 6 27
Average= 4.36 (KJ/cycle)

Cycle 24 GMT 14/ 2/2014 17:41: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.08 27 14.43 500 195 0.19 / 104.57 6 6
2 1116.56 15 13.53 2224 451 0.65 / 105.02 6 6
3 1503.60 50 12.75 2784 1775 2.42 / 106.79 6 6
4 957.76 21 13.35 1971 553 2.97 / 107.34 6 6
5 543.56 21 13.79 1283 372 3.35 / 107.72 6 6
6 38.56 21 14.43 422 128 3.47 / 107.84 6 6
7 0.04 191 14.17 337 912 4.39 / 108.76 6 25
Average= 4.35 (KJ/cycle)

Cycle 23 GMT 4/ 2/2014 20:52: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.20 27 14.43 500 195 0.19 / 100.20 6 6
2 1103.68 15 13.55 2214 450 0.64 / 100.65 6 6
3 1505.12 50 12.74 2808 1789 2.43 / 102.44 6 6
4 1074.68 21 13.26 2177 606 3.04 / 103.05 6 6
5 360.52 21 14.00 991 291 3.33 / 103.34 6 6
6 1.48 21 14.51 350 107 3.44 / 103.45 6 6
7 0.04 191 14.16 342 925 4.36 / 104.37 6 17
Average= 4.35 (KJ/cycle)

Cycle 22 GMT 25/ 1/2014 23:53: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.08 27 14.43 519 202 0.20 / 95.76 6 6
2 1107.04 15 13.59 2185 445 0.65 / 96.21 6 6
3 1505.08 50 12.75 2815 1795 2.44 / 98.00 6 6
4 1221.56 21 13.14 2386 658 3.10 / 98.66 6 6
5 466.40 21 13.89 1149 335 3.44 / 99.00 6 6
6 27.08 21 14.47 401 122 3.56 / 99.12 6 6
7 0.00 190 14.21 330 891 4.45 / 100.01 6 25
Average= 4.35 (KJ/cycle)

Cycle 21 GMT 16/ 1/2014 2:50: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.48 27 14.43 500 195 0.19 / 91.42 6 6
2 1117.12 15 13.55 2237 455 0.65 / 91.87 6 6
3 1501.48 50 12.74 2814 1793 2.44 / 93.66 6 6
4 977.36 21 13.37 1982 556 3.00 / 94.22 6 6
5 394.96 21 13.96 1044 306 3.30 / 94.53 6 6
6 18.00 21 14.45 388 118 3.42 / 94.65 6 6
7 0.40 191 14.16 338 914 4.34 / 95.56 6 24
Average= 4.34 (KJ/cycle)

Cycle 20 GMT 6/ 1/2014 5:45: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.12 27 14.43 538 210 0.21 / 86.98 6 6
2 1193.88 15 13.48 2348 475 0.68 / 87.45 6 6
3 1502.00 50 12.77 2790 1781 2.47 / 89.24 6 6
4 1072.32 21 13.26 2142 596 3.06 / 89.83 6 6
5 527.88 21 13.80 1258 365 3.43 / 90.20 6 6
6 17.24 21 14.46 388 118 3.54 / 90.31 6 6
7 0.68 190 14.15 338 909 4.45 / 91.22 6 24
Average= 4.34 (KJ/cycle)

Cycle 19 GMT 27/12/2013 8:51: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.20 27 14.37 519 201 0.20 / 82.63 6 6
2 1117.00 15 13.44 2211 446 0.65 / 83.08 6 6
3 1501.88 50 12.72 2789 1774 2.42 / 84.85 6 6
4 1076.16 21 13.26 2168 604 3.02 / 85.46 6 6
5 333.20 21 14.01 937 276 3.30 / 85.73 6 6
6 14.08 21 14.45 384 117 3.42 / 85.85 6 7
7 -0.08 191 14.14 341 921 4.34 / 86.77 6 28
Average= 4.34 (KJ/cycle)

Cycle 18 GMT 17/12/2013 11:56: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.72 27 14.37 519 201 0.20 / 78.28 6 6
2 1101.56 15 13.40 2214 445 0.65 / 78.73 6 6
3 1503.08 50 12.73 2778 1768 2.41 / 80.50 6 6
4 1084.04 21 13.23 2144 596 3.01 / 81.09 6 6
5 361.60 21 13.97 982 288 3.30 / 81.38 6 7
6 14.44 21 14.46 386 117 3.42 / 81.50 6 7
7 0.16 191 14.13 346 934 4.35 / 82.43 6 31
Average= 4.34 (KJ/cycle)

Cycle 17 GMT 7/12/2013 14:57: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.84 27 14.37 519 201 0.20 / 74.08 6 6
2 1117.60 15 13.47 2220 449 0.65 / 74.53 6 6
3 1504.12 50 12.75 2774 1768 2.42 / 76.30 6 6
4 950.24 21 13.37 1935 543 2.96 / 76.84 6 6
5 126.12 21 14.31 587 176 3.14 / 77.02 6 6
6 19.88 21 14.43 390 118 3.26 / 77.14 6 7
7 0.20 191 14.15 349 943 4.20 / 78.08 6 29
Average= 4.34 (KJ/cycle)

Cycle 16 GMT 27/11/2013 18:10: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.28 27 14.37 519 201 0.20 / 69.81 6 6
2 1141.16 15 13.40 2259 454 0.66 / 70.27 6 6
3 1504.00 50 12.75 2804 1788 2.44 / 72.05 6 6
4 949.72 21 13.36 1961 550 2.99 / 72.60 6 6
5 397.84 21 13.93 1065 312 3.30 / 72.92 6 7
6 -0.04 190 14.14 360 967 4.27 / 73.88 6 26
Average= 4.35 (KJ/cycle)

Cycle 15 GMT 17/11/2013 21:13: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.72 27 14.37 538 209 0.21 / 65.23 6 6
2 1113.56 15 13.48 2214 448 0.66 / 65.68 6 6
3 1560.08 50 12.68 2891 1833 2.49 / 67.51 6 6
4 1275.12 21 13.10 2469 679 3.17 / 68.19 6 6
5 456.80 21 13.89 1144 334 3.50 / 68.53 6 7
6 32.44 21 14.45 420 127 3.63 / 68.65 6 7
7 0.12 190 14.15 356 957 4.59 / 69.61 6 27
Average= 4.35 (KJ/cycle)

Cycle 14 GMT 7/11/2013 21:36: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.80 26 14.43 519 195 0.19 / 60.69 6 6
2 1045.28 1 14.31 2096 30 0.22 / 60.72 6 6
3 1108.88 15 13.46 2207 446 0.67 / 61.16 6 6
4 1546.88 50 12.72 2873 1827 2.50 / 62.99 6 6
5 1258.04 21 13.12 2444 673 3.17 / 63.67 6 6
6 363.80 21 13.99 999 293 3.46 / 63.96 6 7
7 15.00 21 14.46 394 120 3.58 / 64.08 6 7
8 0.16 191 14.11 351 946 4.53 / 65.02 6 29
Average= 4.33 (KJ/cycle)

Cycle 13 GMT 28/10/2013 22:12: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.24 27 14.43 519 202 0.20 / 56.33 6 6
2 1022.80 1 14.25 2134 30 0.23 / 56.36 6 6
3 962.40 -1 14.25 2134 0. 0.03 / 56.36 6 6
4 1114.92 15 13.60 2191 447 0.68 / 56.81 6 6
5 1536.64 50 12.75 2845 1814 2.49 / 58.62 6 6
6 1269.28 21 13.13 2428 669 3.16 / 59.29 6 6
7 252.16 21 14.16 802 238 3.40 / 59.53 6 7
8 0.04 191 14.16 357 966 4.37 / 60.49 6 24
Average= 4.32 (KJ/cycle)

Cycle 12 GMT 18/10/2013 22:41: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.32 27 14.43 519 202 0.20 / 51.63 6 6
2 1231.36 15 13.50 2387 483 0.69 / 52.11 6 6
3 1585.32 50 12.75 2931 1869 2.55 / 53.98 6 6
4 1453.76 21 12.95 2756 749 3.30 / 54.73 6 6
5 675.64 21 13.67 1514 435 3.74 / 55.16 6 7
6 0.24 191 14.17 356 964 4.70 / 56.13 6 24
Average= 4.32 (KJ/cycle)

Cycle 11 GMT 8/10/2013 23:17: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.48 27 14.43 519 202 0.20 / 47.31 6 6
2 1106.04 15 13.60 2214 452 0.65 / 47.76 6 6
3 1503.48 50 12.85 2788 1791 2.45 / 49.55 6 6
4 1114.12 21 13.26 2230 621 3.07 / 50.17 6 6
5 398.32 21 13.93 1063 311 3.38 / 50.48 6 7
6 0.08 190 14.18 351 946 4.32 / 51.43 6 32
Average= 4.29 (KJ/cycle)

Cycle 10 GMT 29/ 9/2013 2: 5: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.48 26 14.37 538 201 0.20 / 42.98 6 6
2 1110.00 15 13.65 2195 449 0.65 / 43.42 6 6
3 1523.60 50 12.84 2827 1815 2.47 / 45.24 6 6
4 1091.16 21 13.28 2187 610 3.08 / 45.85 6 6
5 356.44 21 14.01 986 290 3.37 / 46.14 6 7
6 0.04 191 14.17 356 964 4.33 / 47.10 6 30
Average= 4.28 (KJ/cycle)

Cycle 9 GMT 19/ 9/2013 3:22:59

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.04 26 14.31 557 207 0.21 / 38.59 6 6
2 1136.64 15 13.62 2262 462 0.67 / 39.05 6 6
3 1506.36 50 12.88 2807 1808 2.48 / 40.86 6 6
4 1098.64 21 13.30 2191 612 3.09 / 41.47 6 6
5 483.80 21 13.85 1204 350 3.44 / 41.82 6 7
6 0.08 191 14.18 352 953 4.39 / 42.77 6 24
Average= 4.28 (KJ/cycle)

Cycle 8 GMT 9/ 9/2013 5:42: 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.84 26 14.43 557 209 0.21 / 33.85 6 6
2 1008.44 4 14.25 2038 116 0.33 / 33.97 6 6
3 874.00 -2 14.25 2038 0. 0.12 / 33.97 6 6
4 929.60 -1 14.25 2038 0. 0.12 / 33.97 6 6
5 1501.76 70 12.74 2775 2475 2.80 / 36.44 6 6
6 807.04 25 13.50 1714 578 3.38 / 37.02 6 7
7 363.72 24 13.98 995 334 3.71 / 37.36 6 7
8 0.80 201 14.14 361 1026 4.74 / 38.38 6 27
Average= 4.26 (KJ/cycle)

Cycle 7 GMT 30/ 8/2013 9:45: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.12 28 14.37 557 224 0.22 / 29.49 6 6
2 918.20 -1 14.37 557 0. 0.00 / 29.49 6 6
3 1508.52 70 12.72 2799 2492 2.72 / 31.98 6 6
4 646.64 24 13.64 1455 476 3.19 / 32.46 6 7
5 79.72 25 14.39 507 182 3.38 / 32.64 6 7
6 0.20 201 14.16 352 1002 4.38 / 33.64 6 28
Average= 4.21 (KJ/cycle)

Cycle 6 GMT 20/ 8/2013 13:22: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.16 24 14.43 557 193 0.19 / 24.57 6 6
2 1037.20 4 14.25 2096 119 0.31 / 24.69 6 6
3 1504.48 70 12.71 2794 2486 2.80 / 27.18 6 6
4 817.24 25 13.47 1745 588 3.39 / 27.77 6 6
5 149.44 24 14.28 639 219 3.60 / 27.98 6 7
6 0.24 251 14.11 362 1282 4.89 / 29.27 6 45
Average= 4.18 (KJ/cycle)

Cycle 5 GMT 10/ 8/2013 17:11: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.76 30 14.37 538 232 0.23 / 19.68 6 6
2 841.80 -2 14.37 538 0. 0.00 / 19.68 6 6
3 887.24 -2 14.37 538 0. 0.00 / 19.68 6 6
4 1512.20 70 12.71 2806 2496 2.73 / 22.17 6 6
5 1038.20 25 13.27 2091 694 3.42 / 22.87 6 6
6 131.12 25 14.28 622 222 3.64 / 23.09 6 7
7 -0.12 251 14.10 365 1292 4.94 / 24.38 6 47
Average= 4.06 (KJ/cycle)

Cycle 4 GMT 31/ 7/2013 21: 6: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.28 27 14.37 557 216 0.22 / 14.86 6 6
2 1509.20 70 12.72 2817 2508 2.72 / 17.37 6 6
3 821.56 24 13.40 1767 568 3.29 / 17.94 6 6
4 151.36 24 14.25 655 224 3.52 / 18.16 6 7
5 0.00 251 14.09 362 1280 4.80 / 19.44 6 48
Average= 3.89 (KJ/cycle)

Cycle 3 GMT 30/ 7/2013 21:33: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.32 27 14.31 557 215 0.22 / 10.07 6 6
2 1507.32 70 12.65 2818 2495 2.71 / 12.57 6 6
3 836.24 24 13.35 1786 572 3.28 / 13.14 6 6
4 155.88 24 14.20 662 226 3.51 / 13.36 6 7
5 0.08 251 14.04 364 1283 4.79 / 14.65 6 44
Average= 3.66 (KJ/cycle)

Cycle 2 GMT 29/ 7/2013 21:54: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.52 27 14.31 538 208 0.21 / 5.40 6 6
2 1455.04 70 12.56 2737 2406 2.61 / 7.81 6 6
3 760.64 25 13.34 1655 552 3.17 / 8.36 6 6
4 127.52 25 14.20 611 217 3.38 / 8.58 6 7
5 0.08 250 14.01 365 1278 4.66 / 9.86 6 44
Average= 3.29 (KJ/cycle)

Cycle 1 GMT 28/ 7/2013 22:28: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.80 24 14.31 538 185 0.18 / 2.01 6 6
2 1009.20 4 13.75 2076 114 0.30 / 2.13 6 6
3 953.16 -1 13.75 2076 0. 0.11 / 2.13 6 6
4 971.84 70 12.88 1975 1781 2.08 / 3.91 6 6
5 0.16 251 13.98 367 1288 3.37 / 5.19 6 32
Average= 2.60 (KJ/cycle)

Cycle 0 GMT 28/ 7/2013 10:49: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 77.56 70 14.28 488 488 0.49 / 0.49 159 6
2 41.20 25 14.32 424 152 0.64 / 0.64 6 6
3 0.48 250 14.05 338 1187 1.83 / 1.83 6 37
Average= 1.83 (KJ/cycle)