SIO Argo Site:
Pump Diagnostics Page   



Serial= 8081 WMO= 5903854

Return

←PreviousNext→

Cycle 62 GMT 16/10/2013 3: 9:32

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.40 39 13.65 538 286 0.29 / 325.01 6 6
2 2003.60 28 10.34 2709 784 1.07 / 325.79 6 6
3 1960.20 21 12.12 2771 705 1.78 / 326.50 6 6
4 1882.20 21 12.26 2689 692 2.47 / 327.19 6 6
5 1587.04 20 12.64 2398 606 3.07 / 327.79 6 7
6 1285.56 20 12.88 2045 527 3.60 / 328.32 6 6
7 851.76 20 13.23 1494 395 4.00 / 328.72 6 6
8 292.84 20 13.67 809 221 4.22 / 328.94 6 6
9 -0.00 20 13.95 446 124 4.34 / 329.06 6 6
10 -0.00 200 13.30 409 1088 5.43 / 330.15 6 25
Average= 5.24 (KJ/cycle)

Cycle 61 GMT 6/10/2013 2:58:31

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.12 38 13.72 538 280 0.28 / 319.54 6 6
2 2005.48 28 10.41 2750 802 1.08 / 320.34 6 6
3 1961.72 21 12.09 2736 695 1.78 / 321.04 6 6
4 1882.20 21 12.25 2747 707 2.48 / 321.75 6 6
5 1683.52 20 12.61 2473 624 3.11 / 322.37 6 6
6 1168.72 20 12.98 1896 492 3.60 / 322.86 6 6
7 852.24 20 13.21 1509 399 4.00 / 323.26 6 6
8 287.32 21 13.64 805 231 4.23 / 323.49 6 6
9 0.32 21 13.92 456 133 4.36 / 323.62 6 6
10 0.28 200 13.27 413 1096 5.46 / 324.72 6 17
Average= 5.24 (KJ/cycle)

Cycle 60

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.20 37 13.59 576 290 0.29 / 314.21 6 6
2 1049.80 1 12.76 1769 23 0.31 / 314.24 6 6
3 2005.92 28 10.28 2781 800 1.11 / 315.04 6 6
4 1957.64 21 12.10 2805 713 1.83 / 315.75 6 6
5 1880.80 21 12.35 2559 664 2.49 / 316.41 6 6
6 1589.64 21 12.59 2354 622 3.11 / 317.04 6 6
7 1167.12 20 12.97 1893 491 3.60 / 317.53 6 6
8 536.04 21 13.42 1129 318 3.92 / 317.85 6 6
9 213.64 20 13.75 713 196 4.12 / 318.04 6 6
10 -0.00 21 13.97 446 131 4.25 / 318.17 6 7
11 -0.08 200 13.29 410 1090 5.34 / 319.26 6 24
Average= 5.23 (KJ/cycle)

Cycle 59 GMT 16/ 9/2013 2:35:45

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.32 35 13.72 557 267 0.27 / 308.69 6 6
2 1097.88 2 13.21 1807 48 0.32 / 308.74 6 6
3 2001.48 28 10.26 2843 817 1.13 / 309.56 6 6
4 1950.28 21 12.10 2764 702 1.83 / 310.26 6 6
5 1869.16 21 12.24 2660 684 2.52 / 310.94 6 6
6 1770.84 21 12.39 2574 670 3.19 / 311.61 6 6
7 1145.84 20 12.99 1857 482 3.67 / 312.09 6 6
8 728.40 21 13.28 1360 379 4.05 / 312.47 6 6
9 182.28 20 13.75 694 191 4.24 / 312.66 6 6
10 0.24 21 13.95 454 133 4.37 / 312.80 6 6
11 0.12 200 13.27 425 1128 5.50 / 313.92 6 23
Average= 5.23 (KJ/cycle)

Cycle 58 GMT 6/ 9/2013 2:32:46

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.68 33 13.53 596 266 0.27 / 303.42 6 6
2 1057.24 1 13.02 1750 23 0.29 / 303.45 6 6
3 2005.64 28 10.43 2758 805 1.09 / 304.25 6 6
4 1950.84 21 12.17 2595 663 1.76 / 304.91 6 7
5 1869.76 21 12.25 2691 692 2.45 / 305.61 6 6
6 1569.00 21 12.60 2341 619 3.07 / 306.23 6 7
7 1147.28 21 12.93 1862 506 3.57 / 306.73 6 6
8 508.20 21 13.46 1093 309 3.88 / 307.04 6 6
9 79.16 21 13.89 535 156 4.04 / 307.20 6 6
10 1.00 21 14.00 444 131 4.17 / 307.33 6 6
11 1.12 200 13.30 412 1096 5.27 / 308.42 6 31
Average= 5.23 (KJ/cycle)

Cycle 57 GMT 27/ 8/2013 1:49:41

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.52 35 13.72 538 258 0.26 / 298.38 6 6
2 950.56 -1 13.72 538 0. 0.00 / 298.38 6 6
3 2002.52 28 10.28 2752 792 1.05 / 299.17 6 6
4 1947.00 21 12.10 2717 690 1.74 / 299.86 6 6
5 1865.64 21 12.26 2666 686 2.43 / 300.55 6 6
6 1472.36 21 12.69 2206 588 3.02 / 301.14 6 6
7 1049.00 20 13.08 1720 450 3.47 / 301.59 6 6
8 498.64 20 13.51 1045 282 3.75 / 301.87 6 7
9 80.68 20 13.92 514 143 3.89 / 302.01 6 6
10 -0.16 21 14.04 407 120 4.01 / 302.13 6 6
11 -0.20 200 13.39 382 1023 5.03 / 303.16 6 22
Average= 5.23 (KJ/cycle)

Cycle 56 GMT 17/ 8/2013 1:15:56

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.00 34 13.78 519 243 0.24 / 293.27 6 6
2 2002.72 28 10.26 2754 791 1.03 / 294.06 6 6
3 1949.08 21 12.18 2657 680 1.71 / 294.74 6 6
4 1869.44 21 12.32 2629 680 2.39 / 295.42 6 6
5 1671.64 21 12.57 2420 639 3.03 / 296.06 6 6
6 1139.28 20 12.97 1850 480 3.51 / 296.54 6 6
7 496.80 20 13.51 1054 285 3.80 / 296.82 6 6
8 84.36 20 13.91 516 144 3.94 / 296.97 6 6
9 0.44 21 14.00 420 123 4.06 / 297.09 6 6
10 0.48 200 13.39 386 1034 5.10 / 298.12 6 26
Average= 5.23 (KJ/cycle)

Cycle 55 GMT 7/ 8/2013 0:30:15

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.00 34 13.78 538 252 0.25 / 288.18 6 6
2 2003.92 28 10.28 2768 797 1.05 / 288.97 6 6
3 1958.52 21 12.11 2726 693 1.74 / 289.67 6 6
4 1878.32 21 12.32 2630 680 2.42 / 290.35 6 6
5 1570.36 21 12.64 2339 621 3.04 / 290.97 6 6
6 1256.12 21 12.91 1948 528 3.57 / 291.50 6 6
7 568.64 21 13.44 1129 319 3.89 / 291.81 6 6
8 126.32 20 13.87 578 160 4.05 / 291.97 6 6
9 1.00 201 13.51 387 1051 5.10 / 293.03 6 22
Average= 5.23 (KJ/cycle)

Cycle 54 GMT 28/ 7/2013 0: 6:32

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.16 34 13.78 538 252 0.25 / 283.20 6 6
2 2002.36 28 10.23 2729 782 1.03 / 283.98 6 6
3 1942.68 21 12.18 2621 670 1.70 / 284.65 6 6
4 1857.08 21 12.35 2578 669 2.37 / 285.32 6 6
5 1664.08 21 12.66 2339 622 2.99 / 285.94 6 6
6 1010.96 20 13.12 1677 440 3.43 / 286.38 6 6
7 590.32 20 13.45 1158 312 3.75 / 286.69 6 6
8 155.52 20 13.83 627 173 3.92 / 286.86 6 6
9 0.16 201 13.52 390 1060 4.98 / 287.92 6 25
Average= 5.23 (KJ/cycle)

Cycle 53 GMT 17/ 7/2013 23:27:35

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.20 34 13.72 557 260 0.26 / 278.00 6 6
2 2005.00 28 10.13 2713 770 1.03 / 278.77 6 6
3 1951.24 21 12.12 2724 693 1.72 / 279.47 6 6
4 1868.88 21 12.27 2610 673 2.40 / 280.14 6 6
5 1665.84 21 12.55 2484 655 3.05 / 280.79 6 6
6 1141.24 20 13.02 1848 481 3.53 / 281.28 6 6
7 613.16 20 13.47 1187 320 3.85 / 281.59 6 6
8 179.64 20 13.85 641 178 4.03 / 281.77 6 6
9 0.44 21 14.07 427 126 4.15 / 281.90 6 6
10 0.24 200 13.41 390 1046 5.20 / 282.94 6 21
Average= 5.24 (KJ/cycle)

Cycle 52 GMT 7/ 7/2013 23: 3:41

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.72 34 13.78 519 243 0.24 / 272.94 6 6
2 2002.12 28 10.14 2828 803 1.05 / 273.74 6 6
3 1947.00 21 12.20 2726 698 1.74 / 274.44 6 6
4 1864.04 21 12.32 2565 664 2.41 / 275.10 6 6
5 1669.72 21 12.64 2409 639 3.05 / 275.74 6 6
6 1042.00 21 13.06 1719 471 3.52 / 276.21 6 6
7 301.84 20 13.70 809 222 3.74 / 276.43 6 6
8 98.56 20 13.93 550 153 3.89 / 276.59 6 6
9 -0.00 21 14.08 420 124 4.02 / 276.71 6 6
10 0.16 200 13.43 385 1034 5.05 / 277.74 6 28
Average= 5.24 (KJ/cycle)

Cycle 51 GMT 27/ 6/2013 22:23: 7

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.16 33 13.85 519 237 0.24 / 267.77 6 6
2 2002.60 28 10.13 2684 761 1.00 / 268.53 6 6
3 1946.68 21 12.18 2683 686 1.68 / 269.21 6 6
4 1865.68 21 12.26 2681 690 2.38 / 269.90 6 6
5 1667.36 21 12.57 2456 648 3.02 / 270.55 6 6
6 1133.52 20 13.07 1814 474 3.50 / 271.03 6 6
7 696.92 20 13.38 1304 349 3.85 / 271.38 6 6
8 65.16 20 13.97 497 139 3.99 / 271.51 6 6
9 0.16 21 14.10 414 123 4.11 / 271.64 6 6
10 -0.00 200 13.42 393 1055 5.16 / 272.69 6 32
Average= 5.24 (KJ/cycle)

Cycle 50 GMT 17/ 6/2013 22: 1:18

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.24 33 13.91 519 238 0.24 / 262.58 6 6
2 2005.00 27 10.11 2753 751 0.99 / 263.33 6 7
3 1954.76 20 12.28 2766 679 1.67 / 264.01 6 6
4 1875.80 20 12.41 2660 660 2.33 / 264.67 6 6
5 1676.84 20 12.67 2470 626 2.96 / 265.30 6 6
6 1249.24 20 13.02 1946 507 3.46 / 265.81 6 6
7 606.12 20 13.45 1184 318 3.78 / 266.12 6 6
8 97.84 20 13.92 538 150 3.93 / 266.27 6 6
9 3.32 20 14.07 415 117 4.05 / 266.39 6 6
10 -0.00 20 13.98 405 113 4.16 / 266.50 6 6
11 -0.08 200 13.39 383 1026 5.19 / 267.53 6 39
Average= 5.25 (KJ/cycle)

Cycle 49 GMT 7/ 6/2013 21:20:54

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.84 33 13.91 538 247 0.25 / 257.50 6 6
2 2004.64 28 10.25 2721 781 1.03 / 258.28 6 6
3 1949.08 21 12.16 2745 701 1.73 / 258.98 6 6
4 1866.60 21 12.33 2638 683 2.41 / 259.66 6 6
5 1561.08 21 12.71 2322 620 3.03 / 260.28 6 6
6 1135.56 21 13.07 1809 497 3.53 / 260.78 6 6
7 393.08 20 13.67 920 252 3.78 / 261.03 6 6
8 81.32 21 13.95 521 153 3.93 / 261.18 6 6
9 0.04 21 14.08 422 125 4.06 / 261.31 6 7
10 -0.00 200 13.46 384 1034 5.09 / 262.34 6 30
Average= 5.25 (KJ/cycle)

Cycle 48 GMT 28/ 5/2013 20:49:32

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.64 32 13.85 538 238 0.24 / 252.23 6 6
2 2003.12 28 9.98 2786 779 1.02 / 253.01 6 6
3 1955.96 21 12.16 2764 706 1.72 / 253.71 6 6
4 1881.36 21 12.33 2647 685 2.41 / 254.40 6 6
5 1784.72 21 12.38 2619 681 3.09 / 255.08 6 6
6 1026.92 20 13.16 1689 445 3.53 / 255.52 6 6
7 497.84 20 13.57 1054 286 3.82 / 255.81 6 6
8 45.36 20 14.00 485 136 3.96 / 255.95 6 6
9 24.28 20 13.99 444 124 4.08 / 256.07 6 6
10 0.28 21 13.98 429 126 4.21 / 256.20 6 6
11 0.28 200 13.38 395 1057 5.26 / 257.25 6 28
Average= 5.25 (KJ/cycle)

Cycle 47 GMT 18/ 5/2013 20:14:16

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.40 32 13.91 538 239 0.24 / 247.06 6 6
2 2007.20 28 10.02 2862 803 1.04 / 247.86 6 6
3 1958.36 21 12.19 2717 696 1.74 / 248.56 6 6
4 1876.24 21 12.36 2662 691 2.43 / 249.25 6 6
5 1571.12 21 12.74 2341 626 3.06 / 249.87 6 6
6 1039.84 20 13.15 1720 452 3.51 / 250.32 6 6
7 613.28 21 13.48 1196 339 3.85 / 250.66 6 6
8 76.40 21 13.98 512 150 4.00 / 250.81 6 6
9 0.28 21 14.09 418 124 4.12 / 250.94 6 6
10 0.04 200 13.46 391 1053 5.17 / 251.99 6 35
Average= 5.25 (KJ/cycle)

Cycle 46 GMT 8/ 5/2013 19:46:15

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.20 31 13.91 557 240 0.24 / 241.76 6 6
2 1056.08 1 13.46 1750 24 0.26 / 241.79 6 6
3 2002.44 28 10.85 2608 792 1.06 / 242.58 6 6
4 1947.80 21 12.27 2715 700 1.76 / 243.28 6 6
5 1867.24 21 12.47 2465 646 2.40 / 243.92 6 6
6 1669.72 21 12.67 2414 642 3.04 / 244.57 6 6
7 1035.68 21 13.18 1685 466 3.51 / 245.03 6 6
8 493.52 21 13.56 1052 300 3.81 / 245.33 6 6
9 160.56 20 13.92 622 173 3.98 / 245.51 6 6
10 28.40 21 14.05 458 135 4.12 / 245.64 6 6
11 0.08 21 14.01 431 127 4.24 / 245.77 6 8
12 -0.04 200 13.42 391 1049 5.29 / 246.82 6 39
Average= 5.25 (KJ/cycle)

Cycle 45 GMT 28/ 4/2013 19:19: 4

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.32 31 13.91 557 240 0.24 / 236.60 6 6
2 2001.72 28 10.88 2684 818 1.06 / 237.41 6 6
3 1945.12 21 12.28 2728 703 1.76 / 238.12 6 6
4 1863.72 21 12.44 2659 695 2.46 / 238.81 6 6
5 1460.12 21 12.84 2215 597 3.05 / 239.41 6 6
6 1152.40 21 13.06 1860 510 3.56 / 239.92 6 6
7 504.44 20 13.58 1071 291 3.85 / 240.21 6 6
8 74.40 20 14.02 511 143 4.00 / 240.35 6 6
9 0.28 21 14.13 414 123 4.12 / 240.48 6 6
10 0.08 200 13.52 387 1046 5.17 / 241.52 6 32
Average= 5.25 (KJ/cycle)

Cycle 44 GMT 18/ 4/2013 18:35:45

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.48 31 13.97 557 241 0.24 / 231.53 6 6
2 2003.04 28 10.54 2744 810 1.05 / 232.34 6 6
3 1948.00 21 12.28 2719 701 1.75 / 233.04 6 6
4 1867.08 21 12.41 2634 686 2.44 / 233.73 6 6
5 1355.96 21 12.95 2082 566 3.00 / 234.29 6 6
6 1147.84 21 13.11 1830 504 3.51 / 234.80 6 6
7 405.32 20 13.69 944 258 3.77 / 235.06 6 6
8 42.68 20 14.05 475 133 3.90 / 235.19 6 6
9 0.04 21 14.08 416 123 4.02 / 235.31 6 7
10 -0.08 200 13.49 387 1044 5.07 / 236.36 6 35
Average= 5.25 (KJ/cycle)

Cycle 43 GMT 8/ 4/2013 17:53:16

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.76 30 13.97 538 225 0.23 / 226.45 6 6
2 2002.68 28 10.71 2870 861 1.09 / 227.31 6 6
3 1939.12 21 12.47 2608 683 1.77 / 227.99 6 6
4 1841.08 21 12.45 2542 665 2.43 / 228.66 6 6
5 1525.88 21 12.83 2287 616 3.05 / 229.27 6 6
6 1015.52 21 13.18 1683 466 3.52 / 229.74 6 6
7 375.32 20 13.73 896 246 3.76 / 229.99 6 6
8 69.44 20 14.06 499 140 3.90 / 230.13 6 6
9 32.88 20 14.05 446 125 4.03 / 230.25 6 6
10 0.80 201 13.57 380 1036 5.06 / 231.29 6 31
Average= 5.26 (KJ/cycle)

Cycle 42 GMT 29/ 3/2013 17:40:26

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.52 31 14.04 519 226 0.23 / 221.34 6 6
2 962.24 -1 14.04 519 0. 0.00 / 221.34 6 6
3 2001.72 28 11.43 2640 845 1.07 / 222.19 6 6
4 1937.20 21 12.36 2723 707 1.78 / 222.89 6 6
5 1845.44 21 12.47 2659 696 2.47 / 223.59 6 6
6 1540.12 21 12.85 2298 620 3.09 / 224.21 6 6
7 1117.24 20 13.19 1792 473 3.57 / 224.68 6 7
8 377.36 21 13.76 892 258 3.82 / 224.94 6 6
9 72.44 21 14.05 497 147 3.97 / 225.09 6 6
10 0.08 20 14.16 405 115 4.09 / 225.20 6 7
11 0.08 200 13.56 377 1022 5.11 / 226.22 6 36
Average= 5.26 (KJ/cycle)

Cycle 41 GMT 19/ 3/2013 17:19:54

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.52 31 13.97 519 225 0.22 / 216.09 6 6
2 2002.12 69 11.18 2649 2043 2.27 / 218.14 6 6
3 1573.52 24 12.71 2307 704 2.97 / 218.84 6 6
4 909.40 25 13.30 1530 509 3.48 / 219.35 6 6
5 230.80 25 13.89 695 241 3.72 / 219.59 6 6
6 19.92 25 14.10 440 155 3.88 / 219.74 6 6
7 0.20 25 14.10 403 142 4.02 / 219.89 6 7
8 0.04 251 13.46 364 1230 5.25 / 221.12 9 48
Average= 5.26 (KJ/cycle)

Cycle 40 GMT 9/ 3/2013 16:38:39

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.88 31 14.04 519 226 0.23 / 210.71 6 6
2 2001.88 69 11.23 2656 2058 2.28 / 212.76 6 7
3 1794.32 25 12.60 2576 811 3.10 / 213.58 6 6
4 1097.64 25 13.14 1772 582 3.68 / 214.16 6 6
5 201.44 25 13.91 666 232 3.91 / 214.39 6 6
6 40.20 25 14.10 461 163 4.07 / 214.55 6 6
7 0.76 251 13.51 388 1316 5.39 / 215.87 6 41
Average= 5.27 (KJ/cycle)

Cycle 39 GMT 27/ 2/2013 16:15: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.60 31 14.04 519 226 0.23 / 205.31 6 6
2 2002.96 69 11.40 2725 2143 2.37 / 207.45 6 6
3 1576.00 24 12.79 2339 718 3.09 / 208.17 6 6
4 893.00 24 13.34 1515 485 3.57 / 208.65 6 6
5 217.36 24 13.91 688 230 3.80 / 208.88 6 6
6 39.84 25 14.08 470 165 3.97 / 209.05 6 6
7 -0.00 25 14.08 412 145 4.11 / 209.19 6 7
8 -0.00 251 13.45 381 1286 5.40 / 210.48 6 44
Average= 5.26 (KJ/cycle)

Cycle 38 GMT 17/ 2/2013 16: 3: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.04 31 13.97 538 233 0.23 / 199.95 6 6
2 2003.20 69 11.60 2643 2115 2.35 / 202.07 6 6
3 1581.68 25 12.79 2324 743 3.09 / 202.81 6 6
4 915.08 25 13.33 1559 520 3.61 / 203.33 6 6
5 443.56 24 13.70 980 322 3.93 / 203.65 6 6
6 -0.08 25 14.17 411 146 4.08 / 203.80 6 6
7 -0.00 251 13.50 379 1284 5.36 / 205.08 6 38
Average= 5.26 (KJ/cycle)

Cycle 37 GMT 7/ 2/2013 15:42:43

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.56 31 14.04 538 234 0.23 / 194.70 6 6
2 2002.12 69 11.69 2700 2178 2.41 / 196.88 6 6
3 1554.96 24 12.85 2324 717 3.13 / 197.59 6 6
4 865.76 24 13.35 1499 480 3.61 / 198.07 6 6
5 169.48 24 14.01 616 207 3.82 / 198.28 6 6
6 14.84 24 14.12 434 147 3.96 / 198.43 6 6
7 0.24 251 13.53 380 1290 5.25 / 199.72 6 40
Average= 5.26 (KJ/cycle)

Cycle 36 GMT 28/ 1/2013 15:20:34

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.96 31 14.04 538 234 0.23 / 189.23 6 6
2 2002.28 69 11.92 2651 2180 2.41 / 191.41 6 15
3 1553.52 24 12.91 2299 712 3.13 / 192.12 6 6
4 856.44 24 13.38 1478 475 3.60 / 192.60 6 6
5 393.44 24 13.76 914 302 3.90 / 192.90 6 6
6 24.80 24 14.13 444 151 4.05 / 193.05 6 6
7 0.24 25 14.10 403 142 4.20 / 193.19 6 7
8 0.20 251 13.47 376 1271 5.47 / 194.46 6 45
Average= 5.26 (KJ/cycle)

Cycle 35 GMT 18/ 1/2013 15: 5: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.24 29 14.10 519 212 0.21 / 183.91 6 6
2 1046.00 1 14.10 1692 24 0.24 / 183.94 6 6
3 2002.00 69 11.92 2690 2212 2.45 / 186.15 6 6
4 1553.60 24 12.95 2253 700 3.15 / 186.85 6 6
5 854.32 25 13.41 1482 497 3.65 / 187.35 6 6
6 163.00 24 14.01 613 206 3.85 / 187.55 6 6
7 -0.28 25 14.20 414 147 4.00 / 187.70 6 6
8 -0.32 251 13.53 382 1297 5.30 / 189.00 6 42
Average= 5.25 (KJ/cycle)

Cycle 34 GMT 8/ 1/2013 14:44: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.40 31 14.04 519 226 0.23 / 178.57 6 6
2 945.48 -1 14.04 519 0. 0.00 / 178.57 6 6
3 2002.20 69 12.00 2706 2241 2.47 / 180.81 6 6
4 1548.24 25 12.97 2305 747 3.21 / 181.56 6 6
5 850.28 24 13.45 1468 474 3.69 / 182.03 6 6
6 174.84 25 13.98 645 225 3.91 / 182.26 6 6
7 0.32 25 14.22 418 149 4.06 / 182.41 6 6
8 0.16 251 13.56 380 1293 5.36 / 183.70 6 44
Average= 5.25 (KJ/cycle)

Cycle 33 GMT 29/12/2012 14:30: 3

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.80 31 14.10 519 227 0.23 / 173.17 6 6
2 2002.32 69 12.12 2720 2275 2.50 / 175.45 6 6
3 1533.44 25 13.00 2272 738 3.24 / 176.19 6 6
4 842.52 25 13.46 1472 495 3.74 / 176.68 6 6
5 169.64 25 14.01 639 224 3.96 / 176.91 6 6
6 0.08 25 14.21 422 150 4.11 / 177.06 6 6
7 0.12 251 13.57 379 1291 5.40 / 178.35 6 44
Average= 5.25 (KJ/cycle)

Cycle 32 GMT 19/12/2012 14:20: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.68 31 14.04 538 234 0.23 / 167.82 6 6
2 2003.00 69 12.21 2672 2251 2.49 / 170.07 6 6
3 1557.20 24 13.04 2270 710 3.20 / 170.78 6 6
4 852.24 25 13.48 1482 499 3.70 / 171.28 6 6
5 171.36 24 14.04 641 216 3.91 / 171.50 6 6
6 0.40 25 14.24 414 147 4.06 / 171.65 6 6
7 0.36 251 13.58 381 1299 5.36 / 172.95 6 43
Average= 5.24 (KJ/cycle)

Cycle 31 GMT 9/12/2012 14:19:48

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.00 32 13.97 557 249 0.25 / 162.46 6 6
2 931.08 -1 13.97 557 0. 0.00 / 162.46 6 6
3 2003.44 69 12.25 2656 2245 2.49 / 164.70 6 6
4 1347.28 25 13.11 2109 691 3.19 / 165.40 6 6
5 889.28 25 13.45 1543 519 3.70 / 165.91 6 6
6 177.80 25 14.05 638 224 3.93 / 166.14 6 6
7 -0.24 25 14.21 416 148 4.08 / 166.29 6 7
8 -0.24 250 13.57 384 1303 5.38 / 167.59 6 42
Average= 5.24 (KJ/cycle)

Cycle 30 GMT 29/11/2012 14: 2: 8

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.80 33 14.10 500 233 0.23 / 157.11 6 6
2 2005.84 69 12.27 2690 2277 2.51 / 159.39 6 6
3 1324.36 25 13.22 2028 670 3.18 / 160.06 6 6
4 659.08 25 13.65 1261 430 3.61 / 160.49 6 6
5 194.92 25 14.03 668 234 3.84 / 160.72 6 6
6 0.28 25 14.28 424 151 4.00 / 160.87 6 6
7 0.28 251 13.57 393 1339 5.33 / 162.21 6 48
Average= 5.23 (KJ/cycle)

Cycle 29 GMT 19/11/2012 14:38:39

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.32 33 14.04 519 240 0.24 / 151.82 6 6
2 2003.36 69 12.29 2727 2313 2.55 / 154.13 6 8
3 1342.76 25 13.19 2080 686 3.24 / 154.82 6 6
4 676.92 25 13.65 1274 435 3.67 / 155.25 6 6
5 99.76 25 14.13 539 190 3.86 / 155.44 6 6
6 0.08 25 14.25 416 148 4.01 / 155.59 6 6
7 -0.00 251 13.60 376 1284 5.30 / 156.88 6 47
Average= 5.23 (KJ/cycle)

Cycle 28 GMT 9/11/2012 15: 5:22

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.52 33 14.04 538 249 0.25 / 146.41 6 6
2 2001.76 69 12.26 2737 2315 2.56 / 148.73 6 6
3 1322.24 25 13.24 2020 669 3.23 / 149.40 6 6
4 853.28 25 13.53 1482 501 3.73 / 149.90 6 6
5 155.72 25 14.09 614 216 3.95 / 150.11 6 6
6 -0.00 25 14.28 422 151 4.10 / 150.26 6 6
7 -0.08 251 13.61 385 1315 5.42 / 151.58 6 43
Average= 5.23 (KJ/cycle)

Cycle 27 GMT 30/10/2012 15:37:29

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.96 32 13.97 557 249 0.25 / 140.93 6 6
2 2001.72 69 12.31 2693 2287 2.54 / 143.21 6 6
3 1547.48 25 13.06 2343 765 3.30 / 143.98 6 6
4 834.44 25 13.53 1492 505 3.81 / 144.48 6 6
5 160.44 25 14.10 624 220 4.03 / 144.70 6 6
6 0.28 25 14.26 418 149 4.18 / 144.85 6 6
7 0.28 251 13.60 384 1311 5.49 / 146.16 6 43
Average= 5.22 (KJ/cycle)

Cycle 26 GMT 20/10/2012 16: 9:27

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.92 32 14.04 538 242 0.24 / 135.48 6 6
2 2003.36 69 12.32 2698 2294 2.54 / 137.77 6 6
3 1331.48 25 13.22 2061 681 3.22 / 138.45 6 6
4 871.44 25 13.55 1505 510 3.73 / 138.96 6 6
5 165.28 25 14.09 639 225 3.95 / 139.19 6 6
6 -0.04 25 14.28 432 154 4.11 / 139.34 6 6
7 -0.04 251 13.59 392 1337 5.44 / 140.68 6 43
Average= 5.21 (KJ/cycle)

Cycle 25 GMT 10/10/2012 16:39:25

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.72 32 14.04 538 242 0.24 / 130.04 6 6
2 2002.52 69 12.38 2634 2250 2.49 / 132.29 6 6
3 1532.96 25 13.09 2313 757 3.25 / 133.04 6 6
4 852.64 25 13.55 1482 502 3.75 / 133.55 6 6
5 156.28 25 14.11 618 218 3.97 / 133.76 6 6
6 0.24 24 14.27 424 145 4.11 / 133.91 6 6
7 0.20 251 13.62 388 1326 5.44 / 135.23 6 45
Average= 5.20 (KJ/cycle)

Cycle 24 GMT 30/ 9/2012 16:52:17

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.76 32 14.10 538 243 0.24 / 124.86 6 6
2 2000.84 69 12.32 2678 2277 2.52 / 127.14 6 6
3 1344.00 25 13.23 2061 682 3.20 / 127.82 6 6
4 672.56 25 13.69 1263 432 3.63 / 128.25 6 6
5 117.24 25 14.17 566 201 3.83 / 128.45 6 6
6 0.72 250 13.71 391 1340 5.17 / 129.79 6 35
Average= 5.19 (KJ/cycle)

Cycle 23 GMT 20/ 9/2012 17: 4:44

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.56 32 14.04 538 242 0.24 / 119.67 6 6
2 2001.24 69 12.34 2686 2287 2.53 / 121.96 6 6
3 1350.12 25 13.22 2101 694 3.22 / 122.65 6 6
4 674.88 25 13.69 1270 435 3.66 / 123.09 6 6
5 110.32 25 14.17 562 199 3.86 / 123.29 6 6
6 0.08 251 13.73 387 1334 5.19 / 124.62 6 42
Average= 5.19 (KJ/cycle)

Cycle 22 GMT 10/ 9/2012 17:21:28

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.40 32 14.10 538 243 0.24 / 114.20 6 6
2 2001.60 69 12.32 2689 2286 2.53 / 116.48 6 6
3 1361.68 25 13.22 2105 696 3.22 / 117.18 6 7
4 916.76 25 13.52 1570 531 3.75 / 117.71 6 6
5 188.24 25 14.09 660 232 3.99 / 117.94 6 6
6 0.24 25 14.30 426 152 4.14 / 118.09 6 6
7 0.20 251 13.64 390 1335 5.47 / 119.43 6 44
Average= 5.19 (KJ/cycle)

Cycle 21 GMT 31/ 8/2012 17:45: 6

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.88 31 14.10 538 235 0.24 / 108.99 6 6
2 2002.48 69 12.33 2668 2270 2.51 / 111.26 6 6
3 1339.60 25 13.23 2064 683 3.19 / 111.94 6 7
4 686.76 25 13.66 1305 446 3.63 / 112.39 6 6
5 125.16 25 14.16 582 206 3.84 / 112.59 6 6
6 -0.04 251 13.72 396 1364 5.20 / 113.96 6 37
Average= 5.18 (KJ/cycle)

Cycle 20 GMT 21/ 8/2012 18: 2: 7

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.12 31 14.10 538 235 0.24 / 103.57 6 6
2 2004.00 69 12.30 2656 2254 2.49 / 105.83 6 6
3 1343.24 25 13.22 2072 685 3.17 / 106.51 6 6
4 878.12 25 13.54 1520 515 3.69 / 107.03 6 6
5 159.20 25 14.13 628 222 3.91 / 107.25 6 6
6 0.24 24 14.30 434 149 4.06 / 107.40 6 6
7 -0.00 251 13.66 395 1354 5.41 / 108.75 6 40
Average= 5.18 (KJ/cycle)

Cycle 19 GMT 11/ 8/2012 18:15:18

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.60 31 14.10 519 227 0.23 / 98.14 6 6
2 2003.40 69 12.36 2592 2211 2.44 / 100.35 6 7
3 1536.96 25 13.11 2265 742 3.18 / 101.09 6 7
4 843.64 25 13.53 1493 505 3.68 / 101.60 6 6
5 181.72 25 14.11 666 235 3.92 / 101.83 6 6
6 0.20 24 14.30 442 152 4.07 / 101.98 6 6
7 0.12 251 13.68 395 1356 5.43 / 103.34 6 45
Average= 5.17 (KJ/cycle)

Cycle 18 GMT 1/ 8/2012 18:34: 3

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.88 31 14.10 557 243 0.24 / 92.67 6 6
2 2003.08 69 12.34 2649 2256 2.50 / 94.92 6 7
3 1539.36 25 13.10 2328 762 3.26 / 95.69 6 6
4 840.64 25 13.57 1478 501 3.76 / 96.19 6 6
5 165.24 25 14.10 640 226 3.99 / 96.41 6 6
6 -0.00 25 14.29 430 154 4.14 / 96.57 6 6
7 0.16 251 13.69 391 1344 5.49 / 97.91 6 39
Average= 5.15 (KJ/cycle)

Cycle 17 GMT 22/ 7/2012 18:55:28

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.12 31 14.10 538 235 0.24 / 87.22 6 6
2 2001.92 69 12.40 2599 2224 2.46 / 89.44 6 6
3 1352.24 25 13.21 2107 696 3.15 / 90.14 6 6
4 887.20 25 13.53 1551 525 3.68 / 90.66 6 6
5 174.00 25 14.12 649 229 3.91 / 90.89 6 6
6 0.56 25 14.30 436 156 4.06 / 91.05 6 6
7 0.08 251 13.70 400 1375 5.44 / 92.42 6 42
Average= 5.13 (KJ/cycle)

Cycle 16 GMT 12/ 7/2012 19:16:21

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.88 29 14.10 557 228 0.23 / 81.69 6 6
2 1054.40 1 14.48 1730 25 0.25 / 81.71 6 6
3 2000.36 69 12.39 2640 2257 2.51 / 83.97 6 6
4 1340.56 25 13.24 2089 691 3.20 / 84.66 6 7
5 657.12 25 13.70 1261 432 3.63 / 85.09 6 6
6 196.84 25 14.12 678 239 3.87 / 85.33 6 6
7 35.76 25 14.24 466 166 4.04 / 85.50 6 6
8 1.16 25 14.23 416 148 4.19 / 85.65 6 8
9 0.04 250 13.67 392 1340 5.53 / 86.99 6 67
Average= 5.12 (KJ/cycle)

Cycle 15 GMT 2/ 7/2012 19:34: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.52 29 14.10 538 220 0.22 / 76.25 6 6
2 2002.48 69 12.43 2622 2249 2.47 / 78.50 6 6
3 1334.96 25 13.23 2082 689 3.16 / 79.18 6 7
4 876.24 25 13.55 1530 518 3.68 / 79.70 6 7
5 184.20 25 14.11 666 235 3.91 / 79.94 6 6
6 0.04 25 14.32 434 155 4.07 / 80.09 6 6
7 -0.00 251 13.74 396 1366 5.43 / 81.46 6 61
Average= 5.09 (KJ/cycle)

Cycle 14 GMT 22/ 6/2012 20:13: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.44 29 14.17 538 221 0.22 / 70.83 6 6
2 2001.24 69 12.48 2665 2295 2.52 / 73.12 6 6
3 1326.16 25 13.25 2072 686 3.20 / 73.81 6 6
4 695.72 25 13.68 1309 448 3.65 / 74.26 6 6
5 235.24 25 14.09 722 254 3.90 / 74.51 6 7
6 0.28 25 14.33 426 153 4.06 / 74.66 6 6
7 0.28 251 13.75 395 1363 5.42 / 76.03 6 55
Average= 5.07 (KJ/cycle)

Cycle 13 GMT 12/ 6/2012 20:53: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.24 29 14.17 538 221 0.22 / 65.31 6 6
2 2002.88 69 12.50 2682 2313 2.53 / 67.62 6 6
3 1536.04 25 13.15 2239 736 3.27 / 68.35 6 7
4 821.56 25 13.63 1432 488 3.76 / 68.84 6 6
5 170.00 25 14.14 639 226 3.98 / 69.07 6 6
6 -0.20 25 14.34 432 155 4.14 / 69.22 6 6
7 -0.20 251 13.75 401 1384 5.52 / 70.61 6 51
Average= 5.04 (KJ/cycle)

Cycle 12 GMT 2/ 6/2012 21:47: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.76 29 14.10 557 228 0.23 / 59.75 6 6
2 2001.84 69 12.55 2637 2284 2.51 / 62.03 6 6
3 1553.52 25 13.13 2347 770 3.28 / 62.80 6 6
4 856.36 25 13.58 1495 508 3.79 / 63.31 6 6
5 171.08 25 14.13 649 229 4.02 / 63.54 6 6
6 0.40 25 14.36 426 153 4.17 / 63.69 6 6
7 0.24 251 13.75 403 1391 5.56 / 65.08 6 56
Average= 5.01 (KJ/cycle)

Cycle 11 GMT 23/ 5/2012 22:29: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.64 29 14.10 557 228 0.23 / 54.18 6 6
2 2002.20 69 12.58 2673 2320 2.55 / 56.50 6 6
3 1531.12 25 13.15 2303 757 3.31 / 57.26 6 6
4 842.12 25 13.60 1476 502 3.81 / 57.76 6 7
5 168.84 25 14.14 638 226 4.03 / 57.99 6 6
6 0.48 25 14.38 426 153 4.19 / 58.14 6 6
7 0.36 251 13.77 400 1383 5.57 / 59.52 6 52
Average= 4.96 (KJ/cycle)

Cycle 10 GMT 13/ 5/2012 23: 1: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.08 28 14.17 576 229 0.23 / 48.63 6 6
2 2003.96 69 12.66 2610 2280 2.51 / 50.91 6 6
3 1358.20 25 13.25 2099 695 3.20 / 51.61 6 6
4 904.16 25 13.52 1574 532 3.74 / 52.14 6 7
5 215.40 25 14.10 705 249 3.98 / 52.39 6 6
6 14.92 25 14.33 451 162 4.15 / 52.55 6 6
7 0.20 251 13.79 406 1405 5.55 / 53.95 6 61
Average= 4.90 (KJ/cycle)

Cycle 9 GMT 3/ 5/2012 23:38: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.36 28 14.17 576 229 0.23 / 43.06 6 6
2 2002.76 69 12.68 2612 2285 2.51 / 45.35 6 6
3 1543.00 25 13.14 2284 750 3.26 / 46.10 6 7
4 857.72 25 13.55 1507 510 3.77 / 46.61 6 7
5 181.96 25 14.15 662 234 4.01 / 46.84 6 6
6 -0.00 25 14.39 430 155 4.16 / 46.99 6 7
7 -0.04 251 13.78 407 1408 5.57 / 48.40 6 58
Average= 4.84 (KJ/cycle)

Cycle 8 GMT 24/ 4/2012 0: 1: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.28 28 14.10 596 235 0.24 / 37.49 6 6
2 2002.08 69 12.73 2543 2234 2.47 / 39.72 6 6
3 1532.52 25 13.13 2316 760 3.23 / 40.48 6 6
4 874.44 25 13.50 1532 517 3.75 / 41.00 6 6
5 202.84 25 14.08 703 247 3.99 / 41.25 6 6
6 0.36 25 14.40 436 157 4.15 / 41.41 6 6
7 0.20 251 13.76 413 1426 5.58 / 42.83 6 52
Average= 4.76 (KJ/cycle)

Cycle 7 GMT 14/ 4/2012 0:33: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.72 28 14.10 576 227 0.23 / 31.94 6 6
2 2005.76 69 12.72 2594 2277 2.50 / 34.22 6 6
3 1342.96 25 13.17 2105 693 3.20 / 34.91 6 7
4 869.80 25 13.50 1534 518 3.71 / 35.43 6 7
5 185.64 25 14.12 670 237 3.95 / 35.67 6 6
6 -0.00 25 14.35 438 157 4.11 / 35.82 6 7
7 -0.00 251 13.73 415 1430 5.54 / 37.25 6 49
Average= 4.66 (KJ/cycle)

Cycle 6 GMT 4/ 4/2012 1: 4: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.72 28 14.10 576 227 0.23 / 26.35 6 6
2 2007.28 69 12.72 2586 2270 2.50 / 28.62 6 6
3 1573.24 25 13.03 2328 758 3.26 / 29.38 6 6
4 858.60 25 13.46 1530 515 3.77 / 29.89 6 8
5 171.44 25 14.11 657 232 4.00 / 30.13 6 6
6 0.20 25 14.36 436 157 4.16 / 30.28 6 6
7 0.24 251 13.73 416 1434 5.59 / 31.72 6 60
Average= 4.53 (KJ/cycle)

Cycle 5 GMT 25/ 3/2012 0:55: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.52 30 14.04 596 251 0.25 / 20.80 6 6
2 929.00 -1 14.04 596 0. 0.00 / 20.80 6 6
3 2012.84 69 12.69 2599 2276 2.53 / 23.07 6 6
4 1576.80 25 13.02 2334 760 3.29 / 23.83 6 8
5 858.96 25 13.45 1528 514 3.80 / 24.34 6 7
6 185.52 25 14.08 668 235 4.04 / 24.58 6 6
7 0.16 25 14.36 442 159 4.19 / 24.74 6 6
8 0.08 251 13.73 402 1385 5.58 / 26.12 6 58
Average= 4.35 (KJ/cycle)

Cycle 4 GMT 15/ 3/2012 0:13: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.32 28 14.04 596 234 0.23 / 15.97 6 6
2 1512.60 68 12.83 2285 1994 2.23 / 17.96 6 6
3 1296.52 25 13.11 2085 683 2.91 / 18.64 6 7
4 553.68 25 13.64 1164 397 3.31 / 19.04 6 7
5 54.72 25 14.21 515 183 3.49 / 19.22 6 6
6 0.48 25 14.29 442 158 3.65 / 19.38 6 6
7 0.40 201 13.67 423 1162 4.81 / 20.54 6 40
Average= 4.11 (KJ/cycle)

Cycle 3 GMT 14/ 3/2012 1:50:37

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.12 28 14.04 557 219 0.22 / 11.37 6 6
2 1505.96 69 12.73 2303 2023 2.24 / 13.39 6 6
3 1070.84 25 13.15 1811 595 2.84 / 13.98 6 8
4 611.20 25 13.53 1232 417 3.25 / 14.40 6 6
5 0.40 25 14.28 461 165 3.42 / 14.57 6 6
6 0.12 201 13.66 425 1167 4.59 / 15.73 6 34
Average= 3.93 (KJ/cycle)

Cycle 2 GMT 13/ 3/2012 3:16: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.00 30 13.91 576 240 0.24 / 6.34 6 6
2 924.88 -1 13.91 576 0. 0.00 / 6.34 6 6
3 1469.60 69 12.63 2205 1922 2.16 / 8.26 6 6
4 1251.20 25 12.94 2024 655 2.82 / 8.92 6 7
5 555.88 25 13.52 1162 393 3.21 / 9.31 6 6
6 26.04 25 14.11 484 171 3.38 / 9.48 6 6
7 -0.08 25 14.10 436 154 3.53 / 9.63 6 6
8 -0.12 269 13.54 416 1515 5.05 / 11.15 6 152
Average= 3.72 (KJ/cycle)

Cycle 1 GMT 12/ 3/2012 3:33: 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.52 25 14.10 576 203 0.20 / 2.59 6 6
2 1047.28 1 13.91 1865 26 0.23 / 2.62 6 6
3 1024.48 68 12.79 1699 1478 1.71 / 4.10 6 7
4 142.08 25 13.90 638 222 1.93 / 4.32 6 6
5 0.12 25 14.17 470 166 2.09 / 4.49 6 6
6 0.16 279 13.53 427 1612 3.71 / 6.10 6 138
Average= 3.05 (KJ/cycle)

Cycle 0 GMT 11/ 3/2012 17:16: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.56 69 13.72 544 515 0.51 / 0.51 156 6
2 89.92 25 14.05 543 191 0.71 / 0.71 6 6
3 42.12 25 14.12 476 168 0.87 / 0.87 6 6
4 0.08 25 14.20 432 153 1.03 / 1.03 6 7
5 0.16 244 13.74 407 1364 2.39 / 2.39 6 157
Average= 2.39 (KJ/cycle)