SIO Argo Site:
Pump Diagnostics Page   



Serial= 8072 WMO= 5903845

Return

←PreviousNext→

Cycle 22 GMT 21/ 3/2012 17:35:39

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.12 31 13.93 673 291 0.29 / 30.79 6 6
2 2003.36 69 12.39 2937 2511 2.80 / 33.30 6 6
3 1277.12 25 13.31 2045 680 3.48 / 33.98 6 6
4 572.92 25 13.76 1230 423 3.91 / 34.41 6 6
5 70.24 25 14.19 635 225 4.13 / 34.63 6 6
6 -0.08 25 14.20 562 200 4.33 / 34.83 6 6
7 -0.20 298 13.28 516 2042 6.37 / 36.87 6 144
Average= 18.44 (KJ/cycle)

Cycle 21 GMT 20/ 3/2012 23:52:31

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.96 31 13.93 673 291 0.29 / 24.43 6 6
2 2001.92 69 12.40 2934 2510 2.80 / 26.94 6 6
3 1087.28 25 13.42 1820 611 3.41 / 27.56 6 6
4 630.48 25 13.73 1291 443 3.85 / 28.00 6 6
5 64.28 25 14.20 628 223 4.08 / 28.22 6 6
6 0.52 25 14.19 574 204 4.28 / 28.43 6 6
7 0.52 295 13.27 530 2075 6.36 / 30.50 6 141
Average= 30.50 (KJ/cycle)

Cycle 18 GMT 18/ 3/2012 17:42:18

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.12 31 14.00 653 283 0.28 / 18.15 6 6
2 2002.96 69 12.41 2951 2527 2.81 / 20.68 6 6
3 1101.16 25 13.40 1851 620 3.43 / 21.30 6 6
4 446.56 25 13.86 1093 379 3.81 / 21.67 6 6
5 47.48 25 14.20 624 222 4.03 / 21.90 6 6
6 0.40 25 14.22 564 201 4.23 / 22.10 6 6
7 0.36 295 13.32 521 2047 6.28 / 24.14 6 141
Average= 24.14 (KJ/cycle)

Cycle 9 GMT 12/ 3/2012 9:36: 7

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.36 29 13.87 673 271 0.27 / 13.93 6 6
2 989.68 68 13.22 1733 1558 1.83 / 15.49 6 6
3 76.44 24 14.14 651 221 2.05 / 15.71 6 6
4 -0.20 25 14.16 564 200 2.25 / 15.91 6 6
5 -0.24 284 13.41 514 1958 4.21 / 17.87 6 139
Average= 17.87 (KJ/cycle)

Cycle 5 GMT 10/ 3/2012 17:47:36

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.36 30 14.00 557 234 0.23 / 9.67 6 6
2 1155.04 69 13.11 1805 1633 1.87 / 11.30 6 6
3 164.68 25 14.05 630 221 2.09 / 11.52 6 6
4 0.16 25 14.22 503 179 2.27 / 11.70 6 6
5 0.08 290 13.45 502 1958 4.22 / 13.66 6 143
Average= 4.55 (KJ/cycle)

Cycle 4 GMT 9/ 3/2012 18:45:16

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.24 30 13.93 557 233 0.23 / 5.90 6 6
2 1101.52 69 13.10 1746 1578 1.81 / 7.48 6 6
3 68.16 25 14.13 517 183 1.99 / 7.66 6 6
4 0.16 25 14.19 442 157 2.15 / 7.82 6 6
5 0.12 295 13.57 403 1613 3.76 / 9.43 6 138
Average= 4.72 (KJ/cycle)

Cycle 3 GMT 8/ 3/2012 19:48:24

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.92 28 14.00 538 211 0.21 / 2.27 6 6
2 1010.92 68 13.11 1634 1457 1.67 / 3.73 6 6
3 93.12 24 14.08 549 186 1.85 / 3.92 6 6
4 0.32 25 14.19 436 155 2.01 / 4.07 6 6
5 0.36 292 13.55 404 1598 3.61 / 5.67 6 154
Average= 5.67 (KJ/cycle)

Cycle 0 GMT 7/ 3/2012 13:37: 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 70.12 69 13.84 466 445 0.45 / 0.45 148 6
2 54.84 25 14.15 451 160 0.60 / 0.60 6 6
3 -0.12 25 14.28 395 141 0.75 / 0.75 6 6
4 -0.16 261 13.84 365 1318 2.06 / 2.06 6 153
Average= 2.06 (KJ/cycle)