SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 37 | 10.69 | 516 | 204 | 0.20 / 1649.92 | 1 | 1 |
2 | 3 | 968.28 | -1 | 11.56 | 0 | 0 | 0.00 / 1649.92 | 1 | 1 |
3 | 3 | 1025.16 | 1 | 8.68 | 2044 | 18 | 0.22 / 1649.94 | 1 | 1 |
4 | 12 | 1151.04 | 140 | 7.98 | 2190 | 2447 | 2.67 / 1652.38 | 1 | 1 |
5 | 7 | 1141.96 | 25 | 8.16 | 2161 | 441 | 3.11 / 1652.82 | 1 | 1 |
6 | 13 | 178.84 | 55 | 10.32 | 629 | 357 | 3.47 / 1653.18 | 1 | 1 |
7 | 13 | 17.72 | 55 | 10.79 | 334 | 198 | 3.66 / 1653.38 | 1 | 1 |
8 | 8 | 0.04 | 160 | 10.79 | 341 | 589 | 4.25 / 1653.97 | 1 | 243 |
Average= | 5.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 40 | 10.70 | 516 | 221 | 0.22 / 1645.89 | 1 | 1 |
2 | 3 | 902.28 | -2 | 11.56 | 0 | 0 | 0.00 / 1645.89 | 1 | 1 |
3 | 12 | 1117.48 | 140 | 8.17 | 2138 | 2445 | 2.67 / 1648.34 | 1 | 1 |
4 | 7 | 1107.72 | 25 | 8.28 | 2108 | 436 | 3.10 / 1648.77 | 1 | 1 |
5 | 13 | 159.44 | 55 | 10.39 | 604 | 345 | 3.45 / 1649.12 | 1 | 1 |
6 | 8 | 0.04 | 160 | 10.81 | 345 | 597 | 4.04 / 1649.72 | 1 | 1 |
Average= | 5.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 50 | 10.74 | 514 | 276 | 0.28 / 1641.45 | 1 | 1 |
2 | 3 | 594.16 | -8 | 11.55 | 0 | 0 | 0.00 / 1641.45 | 1 | 1 |
3 | 3 | 906.96 | -2 | 11.56 | 0 | 0 | 0.00 / 1641.45 | 1 | 1 |
4 | 12 | 1165.64 | 140 | 8.20 | 2211 | 2538 | 2.81 / 1643.99 | 1 | 1 |
5 | 7 | 1157.80 | 25 | 8.30 | 2193 | 455 | 3.27 / 1644.44 | 1 | 1 |
6 | 13 | 194.68 | 55 | 10.32 | 681 | 387 | 3.66 / 1644.83 | 1 | 1 |
7 | 13 | 43.56 | 55 | 10.71 | 420 | 247 | 3.90 / 1645.08 | 1 | 1 |
8 | 8 | -0.08 | 160 | 10.83 | 342 | 593 | 4.50 / 1645.67 | 1 | 187 |
Average= | 5.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 39 | 10.73 | 527 | 221 | 0.22 / 1634.49 | 1 | 1 |
2 | 3 | 918.84 | -2 | 11.56 | 0 | 0 | 0.00 / 1634.49 | 1 | 1 |
3 | 12 | 1129.36 | 4 | 8.35 | 2177 | 73 | 0.29 / 1634.57 | 1 | 1 |
4 | 12 | 1991.20 | 140 | 6.75 | 3567 | 3371 | 3.66 / 1637.94 | 1 | 1 |
5 | 7 | 1982.92 | 25 | 6.65 | 3552 | 591 | 4.25 / 1638.53 | 1 | 1 |
6 | 13 | 1399.36 | 55 | 7.91 | 2618 | 1139 | 5.39 / 1639.67 | 1 | 1 |
7 | 13 | 487.88 | 55 | 9.71 | 1182 | 631 | 6.02 / 1640.30 | 1 | 1 |
8 | 13 | 71.12 | 55 | 10.66 | 479 | 281 | 6.31 / 1640.58 | 1 | 1 |
9 | 8 | 0.08 | 160 | 10.86 | 343 | 596 | 6.90 / 1641.17 | 1 | 1 |
Average= | 5.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 39 | 10.77 | 508 | 213 | 0.21 / 1630.39 | 1 | 1 |
2 | 3 | 925.64 | -1 | 11.56 | 0 | 0 | 0.00 / 1630.39 | 1 | 1 |
3 | 12 | 1111.20 | 140 | 8.49 | 2129 | 2531 | 2.74 / 1632.92 | 1 | 1 |
4 | 7 | 1101.68 | 24 | 8.62 | 2111 | 437 | 3.18 / 1633.35 | 1 | 1 |
5 | 13 | 145.72 | 55 | 10.53 | 571 | 331 | 3.51 / 1633.69 | 1 | 1 |
6 | 8 | 0.08 | 160 | 10.87 | 338 | 588 | 4.10 / 1634.27 | 1 | 1 |
Average= | 5.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 77 | 10.73 | 498 | 411 | 0.41 / 1626.28 | 1 | 1 |
2 | 3 | 170.68 | -16 | 11.54 | 0 | 0 | 0.00 / 1626.28 | 1 | 1 |
3 | 3 | 602.88 | -8 | 11.56 | 0 | 0 | 0.00 / 1626.28 | 1 | 1 |
4 | 12 | 1120.20 | 140 | 8.47 | 2182 | 2587 | 3.00 / 1628.87 | 1 | 1 |
5 | 7 | 1109.44 | 25 | 8.55 | 2152 | 460 | 3.46 / 1629.33 | 1 | 1 |
6 | 13 | 62.64 | 55 | 10.72 | 447 | 264 | 3.72 / 1629.59 | 1 | 1 |
7 | 8 | 0.08 | 160 | 10.88 | 334 | 581 | 4.30 / 1630.17 | 1 | 2 |
Average= | 5.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 10 | 2030.40 | 17 | 5.91 | 3681 | 370 | 0.37 / 1618.54 | 1 | 1 |
2 | 3 | 2031.04 | 26 | 5.97 | 3911 | 607 | 0.98 / 1619.15 | 1 | 1 |
3 | 3 | 1952.00 | 24 | 6.77 | 3431 | 557 | 1.53 / 1619.71 | 1 | 1 |
4 | 12 | 1907.04 | 140 | 6.57 | 3477 | 3198 | 4.73 / 1622.90 | 1 | 1 |
5 | 7 | 1899.56 | 25 | 6.49 | 3428 | 556 | 5.29 / 1623.46 | 1 | 1 |
6 | 13 | 1209.72 | 55 | 8.09 | 2317 | 1031 | 6.32 / 1624.49 | 1 | 1 |
7 | 13 | 352.48 | 55 | 9.94 | 958 | 524 | 6.84 / 1625.02 | 1 | 1 |
8 | 13 | 61.60 | 55 | 10.69 | 453 | 266 | 7.11 / 1625.28 | 1 | 1 |
9 | 8 | 0.00 | 160 | 10.85 | 339 | 589 | 7.70 / 1625.87 | 1 | 1 |
Average= | 5.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 31 | 10.46 | 507 | 164 | 0.16 / 1578.05 | 1 | 1 |
2 | 10 | 1042.52 | 4 | 7.86 | 1996 | 63 | 0.23 / 1578.12 | 1 | 1 |
3 | 3 | 1104.72 | 3 | 7.48 | 2110 | 47 | 0.27 / 1578.16 | 1 | 1 |
4 | 3 | 1070.44 | 2 | 7.65 | 2043 | 31 | 0.31 / 1578.19 | 1 | 1 |
5 | 12 | 1160.04 | 4 | 7.14 | 2178 | 62 | 0.37 / 1578.26 | 1 | 1 |
6 | 12 | 2006.36 | 140 | 5.65 | 2674 | 2115 | 2.48 / 1580.37 | 1 | 1 |
7 | 7 | 2007.96 | 25 | 5.71 | 2413 | 344 | 2.83 / 1580.72 | 1 | 1 |
8 | 13 | 2023.44 | 55 | 5.76 | 2789 | 884 | 3.71 / 1581.60 | 1 | 1 |
9 | 13 | 2024.16 | 55 | 5.80 | 2897 | 924 | 4.64 / 1582.52 | 1 | 1 |
10 | 13 | 2027.08 | 55 | 5.80 | 2982 | 951 | 5.59 / 1583.48 | 1 | 1 |
11 | 13 | 2026.64 | 55 | 5.82 | 3052 | 977 | 6.56 / 1584.45 | 1 | 1 |
12 | 13 | 2034.28 | 55 | 5.83 | 3119 | 1000 | 7.56 / 1585.45 | 1 | 1 |
13 | 13 | 2041.36 | 55 | 5.85 | 3176 | 1022 | 8.59 / 1586.47 | 1 | 1 |
14 | 13 | 2036.32 | 55 | 5.86 | 3224 | 1039 | 9.62 / 1587.51 | 1 | 1 |
15 | 13 | 2029.28 | 55 | 5.86 | 3276 | 1056 | 10.68 / 1588.57 | 1 | 1 |
16 | 13 | 2026.24 | 55 | 5.89 | 3313 | 1073 | 11.75 / 1589.64 | 1 | 1 |
17 | 13 | 2037.00 | 55 | 5.88 | 3362 | 1087 | 12.84 / 1590.73 | 1 | 1 |
18 | 13 | 2046.20 | 55 | 5.90 | 3400 | 1103 | 13.94 / 1591.83 | 1 | 1 |
19 | 13 | 2045.36 | 55 | 5.89 | 3443 | 1115 | 15.06 / 1592.95 | 1 | 1 |
20 | 13 | 2041.08 | 55 | 5.90 | 3479 | 1129 | 16.19 / 1594.08 | 1 | 1 |
21 | 13 | 2048.80 | 55 | 5.91 | 3511 | 1141 | 17.33 / 1595.22 | 1 | 1 |
22 | 13 | 2051.52 | 55 | 5.92 | 3541 | 1153 | 18.48 / 1596.37 | 1 | 1 |
23 | 13 | 2042.76 | 55 | 5.92 | 3567 | 1161 | 19.64 / 1597.53 | 1 | 1 |
24 | 13 | 2036.76 | 55 | 5.93 | 3597 | 1173 | 20.82 / 1598.71 | 1 | 1 |
25 | 13 | 2036.20 | 55 | 5.93 | 3628 | 1183 | 22.00 / 1599.89 | 1 | 1 |
26 | 13 | 2041.52 | 55 | 5.93 | 3653 | 1191 | 23.19 / 1601.08 | 1 | 1 |
27 | 13 | 2045.40 | 55 | 5.94 | 3677 | 1201 | 24.39 / 1602.28 | 1 | 1 |
28 | 13 | 2037.68 | 55 | 5.95 | 3695 | 1209 | 25.60 / 1603.49 | 1 | 1 |
29 | 13 | 2026.88 | 55 | 5.96 | 3718 | 1219 | 26.82 / 1604.71 | 1 | 1 |
30 | 13 | 2026.52 | 55 | 5.95 | 3741 | 1224 | 28.05 / 1605.93 | 1 | 1 |
31 | 13 | 2037.64 | 55 | 5.96 | 3754 | 1231 | 29.28 / 1607.17 | 1 | 1 |
32 | 13 | 2039.44 | 55 | 5.97 | 3812 | 1252 | 30.53 / 1608.42 | 1 | 1 |
33 | 13 | 2039.40 | 55 | 5.98 | 3835 | 1261 | 31.79 / 1609.68 | 1 | 1 |
34 | 13 | 2033.16 | 55 | 5.97 | 3859 | 1267 | 33.06 / 1610.95 | 1 | 1 |
35 | 13 | 2025.52 | 55 | 5.98 | 3875 | 1274 | 34.33 / 1612.22 | 1 | 1 |
36 | 13 | 2032.28 | 55 | 6.00 | 3881 | 1281 | 35.61 / 1613.50 | 1 | 1 |
37 | 13 | 2051.68 | 55 | 5.99 | 3908 | 1287 | 36.90 / 1614.79 | 1 | 1 |
38 | 8 | 2053.80 | 160 | 5.83 | 3628 | 3384 | 40.28 / 1618.17 | 1 | 1 |
Average= | 5.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 29 | 10.71 | 508 | 158 | 0.16 / 1573.55 | 1 | 1 |
2 | 10 | 1001.00 | 3 | 8.64 | 1942 | 50 | 0.21 / 1573.60 | 1 | 1 |
3 | 10 | 1029.32 | 3 | 8.55 | 2015 | 52 | 0.26 / 1573.65 | 1 | 1 |
4 | 10 | 1057.68 | 3 | 8.47 | 2046 | 52 | 0.31 / 1573.70 | 1 | 1 |
5 | 3 | 1055.76 | 1 | 8.43 | 2030 | 17 | 0.33 / 1573.72 | 1 | 1 |
6 | 3 | 1036.80 | 1 | 8.45 | 2023 | 17 | 0.35 / 1573.74 | 1 | 1 |
7 | 12 | 1156.68 | 140 | 6.55 | 2144 | 1966 | 2.31 / 1575.70 | 1 | 1 |
8 | 7 | 1150.24 | 25 | 6.32 | 2140 | 338 | 2.65 / 1576.04 | 1 | 1 |
9 | 13 | 873.84 | 55 | 7.87 | 1720 | 745 | 3.39 / 1576.78 | 1 | 1 |
10 | 13 | 148.72 | 55 | 10.14 | 573 | 320 | 3.71 / 1577.10 | 1 | 1 |
11 | 13 | 29.96 | 55 | 10.53 | 381 | 221 | 3.93 / 1577.32 | 1 | 1 |
12 | 8 | -0.04 | 160 | 10.63 | 332 | 565 | 4.50 / 1577.89 | 1 | 44 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 33 | 10.96 | 499 | 180 | 0.18 / 1569.39 | 1 | 1 |
2 | 3 | 1054.80 | 1 | 9.17 | 2075 | 19 | 0.20 / 1569.41 | 1 | 1 |
3 | 3 | 1030.16 | 1 | 9.15 | 2039 | 19 | 0.22 / 1569.43 | 1 | 1 |
4 | 12 | 1157.84 | 140 | 6.86 | 2159 | 2074 | 2.29 / 1571.50 | 1 | 1 |
5 | 7 | 1150.00 | 25 | 7.10 | 2148 | 381 | 2.67 / 1571.88 | 1 | 1 |
6 | 13 | 591.60 | 55 | 9.09 | 1297 | 648 | 3.32 / 1572.53 | 1 | 1 |
7 | 13 | 123.28 | 55 | 10.47 | 513 | 295 | 3.62 / 1572.83 | 1 | 1 |
8 | 8 | -0.04 | 160 | 10.82 | 326 | 564 | 4.18 / 1573.39 | 1 | 1 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 28 | 11.79 | 526 | 174 | 0.17 / 1564.88 | 1 | 1 |
2 | 10 | 1011.68 | 3 | 10.65 | 2007 | 64 | 0.24 / 1564.95 | 1 | 1 |
3 | 3 | 1069.92 | 2 | 10.50 | 2114 | 44 | 0.28 / 1564.99 | 1 | 1 |
4 | 3 | 1027.92 | 1 | 10.40 | 2059 | 21 | 0.30 / 1565.01 | 1 | 1 |
5 | 12 | 1154.92 | 140 | 8.34 | 2192 | 2559 | 2.86 / 1567.57 | 1 | 1 |
6 | 7 | 1146.12 | 25 | 8.09 | 2161 | 437 | 3.30 / 1568.01 | 1 | 1 |
7 | 13 | 174.96 | 55 | 10.61 | 614 | 358 | 3.66 / 1568.37 | 1 | 1 |
8 | 13 | 38.64 | 55 | 10.95 | 408 | 246 | 3.90 / 1568.61 | 1 | 1 |
9 | 8 | -0.04 | 160 | 11.03 | 337 | 595 | 4.50 / 1569.21 | 1 | 243 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 27 | 12.43 | 524 | 176 | 0.18 / 1557.09 | 1 | 1 |
2 | 10 | 1013.64 | 5 | 11.20 | 2032 | 114 | 0.29 / 1557.20 | 1 | 1 |
3 | 12 | 1127.60 | 4 | 10.75 | 2225 | 96 | 0.39 / 1557.30 | 1 | 1 |
4 | 12 | 1983.12 | 140 | 6.92 | 3399 | 3293 | 3.68 / 1560.59 | 1 | 1 |
5 | 7 | 1976.24 | 25 | 6.46 | 3454 | 558 | 4.24 / 1561.15 | 1 | 1 |
6 | 13 | 1842.40 | 55 | 7.97 | 3322 | 1456 | 5.69 / 1562.61 | 1 | 1 |
7 | 13 | 1086.20 | 55 | 9.33 | 2126 | 1091 | 6.78 / 1563.70 | 1 | 1 |
8 | 13 | 138.84 | 55 | 11.35 | 600 | 375 | 7.16 / 1564.07 | 1 | 1 |
9 | 8 | 0.20 | 160 | 11.67 | 342 | 639 | 7.80 / 1564.71 | 1 | 1 |
Average= | 5.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 27 | 13.25 | 526 | 188 | 0.19 / 1551.10 | 1 | 1 |
2 | 3 | 1053.72 | 1 | 11.39 | 2098 | 24 | 0.21 / 1551.12 | 1 | 1 |
3 | 3 | 1031.44 | 1 | 11.19 | 2072 | 23 | 0.24 / 1551.14 | 1 | 1 |
4 | 12 | 1151.40 | 140 | 5.53 | 2037 | 1577 | 1.81 / 1552.72 | 1 | 1 |
5 | 7 | 1158.68 | 25 | 8.36 | 2201 | 460 | 2.27 / 1553.18 | 1 | 1 |
6 | 13 | 1259.44 | 55 | 7.69 | 2338 | 989 | 3.26 / 1554.17 | 1 | 1 |
7 | 13 | 1161.60 | 55 | 8.35 | 2192 | 1007 | 4.27 / 1555.17 | 1 | 1 |
8 | 13 | 598.24 | 55 | 10.35 | 1324 | 754 | 5.02 / 1555.93 | 1 | 1 |
9 | 13 | 67.76 | 55 | 12.07 | 474 | 315 | 5.34 / 1556.24 | 1 | 1 |
10 | 8 | 0.04 | 160 | 12.14 | 345 | 670 | 6.01 / 1556.91 | 1 | 14 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 27 | 13.59 | 548 | 201 | 0.20 / 1545.13 | 1 | 1 |
2 | 3 | 1036.28 | 1 | 11.48 | 2070 | 24 | 0.22 / 1545.16 | 1 | 1 |
3 | 12 | 1157.76 | 140 | 5.46 | 1695 | 1296 | 1.52 / 1546.45 | 1 | 1 |
4 | 7 | 1163.96 | 24 | 8.48 | 2217 | 451 | 1.97 / 1546.90 | 1 | 1 |
5 | 13 | 1231.84 | 55 | 7.00 | 2249 | 866 | 2.84 / 1547.77 | 1 | 1 |
6 | 13 | 1180.76 | 55 | 8.05 | 2218 | 982 | 3.82 / 1548.75 | 1 | 1 |
7 | 13 | 1058.40 | 55 | 9.12 | 2040 | 1023 | 4.84 / 1549.77 | 1 | 1 |
8 | 13 | 142.84 | 55 | 12.53 | 587 | 405 | 5.25 / 1550.18 | 1 | 1 |
9 | 8 | 0.12 | 160 | 12.97 | 351 | 728 | 5.98 / 1550.91 | 1 | 2 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 27 | 13.99 | 543 | 205 | 0.21 / 1540.43 | 1 | 1 |
2 | 12 | 1148.64 | 140 | 6.10 | 2113 | 1805 | 2.01 / 1542.24 | 1 | 1 |
3 | 7 | 1143.96 | 25 | 9.38 | 2196 | 515 | 2.52 / 1542.75 | 1 | 1 |
4 | 13 | 881.12 | 55 | 10.17 | 1756 | 982 | 3.51 / 1543.73 | 1 | 1 |
5 | 13 | 117.32 | 55 | 13.13 | 568 | 410 | 3.92 / 1544.14 | 1 | 1 |
6 | 8 | 0.00 | 160 | 13.39 | 367 | 786 | 4.70 / 1544.93 | 1 | 69 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 27 | 14.02 | 550 | 208 | 0.21 / 1533.09 | 1 | 1 |
2 | 12 | 1129.28 | 4 | 11.14 | 2198 | 98 | 0.31 / 1533.18 | 1 | 1 |
3 | 12 | 1976.36 | 140 | 7.43 | 3522 | 3664 | 3.97 / 1536.85 | 1 | 1 |
4 | 7 | 1967.80 | 25 | 9.12 | 3566 | 813 | 4.78 / 1537.66 | 1 | 1 |
5 | 13 | 1076.64 | 55 | 11.45 | 2074 | 1306 | 6.09 / 1538.97 | 1 | 1 |
6 | 13 | 110.64 | 55 | 13.59 | 581 | 434 | 6.52 / 1539.40 | 1 | 1 |
7 | 8 | -0.08 | 160 | 13.75 | 376 | 827 | 7.35 / 1540.23 | 1 | 243 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 27 | 14.13 | 550 | 210 | 0.21 / 1527.12 | 1 | 1 |
2 | 12 | 1120.48 | 140 | 5.47 | 1750 | 1340 | 1.55 / 1528.46 | 1 | 1 |
3 | 7 | 1125.68 | 24 | 9.11 | 2164 | 473 | 2.02 / 1528.93 | 1 | 1 |
4 | 13 | 1209.72 | 55 | 7.97 | 2263 | 992 | 3.02 / 1529.93 | 1 | 1 |
5 | 13 | 1131.00 | 55 | 9.03 | 2155 | 1070 | 4.09 / 1531.00 | 1 | 1 |
6 | 13 | 408.84 | 55 | 12.70 | 1039 | 726 | 4.81 / 1531.72 | 1 | 1 |
7 | 13 | 22.00 | 55 | 13.94 | 423 | 324 | 5.14 / 1532.05 | 1 | 1 |
8 | 8 | 0.04 | 160 | 13.89 | 374 | 831 | 5.97 / 1532.88 | 1 | 243 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 27 | 14.12 | 543 | 207 | 0.21 / 1521.17 | 1 | 1 |
2 | 12 | 1147.04 | 140 | 5.50 | 1898 | 1461 | 1.67 / 1522.63 | 1 | 1 |
3 | 7 | 1152.76 | 24 | 9.41 | 2220 | 501 | 2.17 / 1523.13 | 1 | 1 |
4 | 13 | 1222.80 | 55 | 8.55 | 2301 | 1082 | 3.25 / 1524.22 | 1 | 1 |
5 | 13 | 1129.84 | 55 | 9.65 | 2165 | 1149 | 4.40 / 1525.37 | 1 | 1 |
6 | 13 | 371.44 | 55 | 12.94 | 980 | 697 | 5.10 / 1526.06 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.02 | 378 | 848 | 5.95 / 1526.91 | 1 | 2 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 27 | 14.20 | 550 | 211 | 0.21 / 1516.48 | 1 | 1 |
2 | 12 | 1115.56 | 140 | 6.55 | 2077 | 1905 | 2.12 / 1518.39 | 1 | 1 |
3 | 7 | 1109.24 | 25 | 9.87 | 2144 | 529 | 2.64 / 1518.91 | 1 | 1 |
4 | 13 | 563.16 | 55 | 12.48 | 1258 | 863 | 3.51 / 1519.78 | 1 | 1 |
5 | 13 | 42.92 | 55 | 13.95 | 461 | 354 | 3.86 / 1520.13 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.06 | 370 | 832 | 4.69 / 1520.96 | 1 | 243 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 27 | 14.10 | 560 | 213 | 0.21 / 1509.11 | 1 | 1 |
2 | 12 | 1096.12 | 4 | 11.13 | 2161 | 96 | 0.31 / 1509.20 | 1 | 1 |
3 | 12 | 1972.64 | 140 | 7.90 | 3548 | 3924 | 4.23 / 1513.13 | 1 | 1 |
4 | 7 | 1963.60 | 25 | 9.66 | 3544 | 856 | 5.09 / 1513.98 | 1 | 1 |
5 | 13 | 665.28 | 55 | 12.74 | 1494 | 1047 | 6.14 / 1515.03 | 1 | 1 |
6 | 13 | 49.76 | 55 | 14.03 | 490 | 378 | 6.51 / 1515.41 | 1 | 1 |
7 | 8 | -0.04 | 160 | 14.14 | 382 | 864 | 7.38 / 1516.27 | 1 | 243 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 27 | 14.13 | 545 | 208 | 0.21 / 1503.04 | 1 | 1 |
2 | 12 | 1130.92 | 140 | 5.52 | 1980 | 1530 | 1.74 / 1504.57 | 1 | 1 |
3 | 7 | 1135.96 | 25 | 9.44 | 2200 | 519 | 2.26 / 1505.09 | 1 | 1 |
4 | 13 | 1199.60 | 55 | 9.61 | 2289 | 1210 | 3.47 / 1506.30 | 1 | 1 |
5 | 13 | 1085.44 | 55 | 10.51 | 2122 | 1227 | 4.69 / 1507.52 | 1 | 1 |
6 | 13 | 161.96 | 55 | 13.65 | 665 | 499 | 5.19 / 1508.02 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.10 | 385 | 869 | 6.06 / 1508.89 | 1 | 217 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 27 | 14.16 | 544 | 208 | 0.21 / 1496.96 | 1 | 1 |
2 | 12 | 1138.00 | 140 | 5.52 | 2028 | 1567 | 1.78 / 1498.53 | 1 | 1 |
3 | 7 | 1143.92 | 25 | 9.44 | 2193 | 518 | 2.29 / 1499.05 | 1 | 1 |
4 | 13 | 1205.96 | 55 | 9.72 | 2289 | 1224 | 3.52 / 1500.27 | 1 | 1 |
5 | 13 | 1104.80 | 55 | 10.61 | 2115 | 1234 | 4.75 / 1501.51 | 1 | 1 |
6 | 13 | 143.32 | 55 | 13.71 | 630 | 475 | 5.23 / 1501.98 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.14 | 375 | 848 | 6.07 / 1502.83 | 1 | 221 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 27 | 14.22 | 549 | 211 | 0.21 / 1492.24 | 1 | 1 |
2 | 12 | 1139.00 | 140 | 6.94 | 2120 | 2060 | 2.27 / 1494.30 | 1 | 1 |
3 | 7 | 1132.72 | 25 | 10.16 | 2173 | 552 | 2.82 / 1494.85 | 1 | 1 |
4 | 13 | 417.44 | 55 | 13.20 | 978 | 710 | 3.53 / 1495.56 | 1 | 1 |
5 | 13 | 49.88 | 55 | 14.03 | 471 | 363 | 3.90 / 1495.92 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.18 | 368 | 835 | 4.73 / 1496.76 | 1 | 243 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 27 | 14.16 | 569 | 218 | 0.22 / 1484.94 | 1 | 1 |
2 | 12 | 1108.24 | 4 | 11.20 | 2170 | 97 | 0.31 / 1485.03 | 1 | 1 |
3 | 12 | 1975.48 | 140 | 8.08 | 3554 | 4020 | 4.34 / 1489.05 | 1 | 1 |
4 | 7 | 1965.76 | 25 | 9.83 | 3563 | 876 | 5.21 / 1489.93 | 1 | 1 |
5 | 13 | 497.08 | 55 | 13.22 | 1186 | 862 | 6.07 / 1490.79 | 1 | 1 |
6 | 13 | 65.52 | 55 | 14.06 | 511 | 395 | 6.47 / 1491.19 | 1 | 1 |
7 | 8 | -0.04 | 160 | 14.26 | 367 | 837 | 7.31 / 1492.03 | 1 | 243 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 27 | 14.12 | 559 | 213 | 0.21 / 1478.72 | 1 | 1 |
2 | 12 | 1140.52 | 140 | 5.53 | 2049 | 1586 | 1.80 / 1480.30 | 1 | 1 |
3 | 7 | 1147.68 | 25 | 9.69 | 2214 | 536 | 2.34 / 1480.84 | 1 | 1 |
4 | 13 | 1236.60 | 55 | 10.18 | 2356 | 1319 | 3.65 / 1482.16 | 1 | 1 |
5 | 13 | 975.88 | 55 | 11.55 | 1886 | 1198 | 4.85 / 1483.36 | 1 | 1 |
6 | 13 | 153.32 | 55 | 13.75 | 637 | 482 | 5.33 / 1483.84 | 1 | 1 |
7 | 8 | 0.08 | 160 | 14.14 | 390 | 882 | 6.22 / 1484.72 | 1 | 243 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.96 | 27 | 14.12 | 564 | 215 | 0.22 / 1472.45 | 1 | 1 |
2 | 12 | 1146.56 | 140 | 5.54 | 2042 | 1584 | 1.80 / 1474.03 | 1 | 1 |
3 | 7 | 1152.00 | 24 | 9.82 | 2228 | 525 | 2.32 / 1474.55 | 1 | 1 |
4 | 13 | 1217.72 | 55 | 10.13 | 2331 | 1299 | 3.62 / 1475.85 | 1 | 1 |
5 | 13 | 1106.40 | 55 | 10.87 | 2153 | 1287 | 4.91 / 1477.14 | 1 | 1 |
6 | 13 | 147.04 | 55 | 13.75 | 648 | 490 | 5.40 / 1477.63 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.16 | 385 | 872 | 6.27 / 1478.50 | 1 | 243 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 27 | 14.19 | 557 | 213 | 0.21 / 1468.01 | 1 | 1 |
2 | 12 | 1122.56 | 140 | 7.01 | 2094 | 2055 | 2.27 / 1470.07 | 1 | 1 |
3 | 7 | 1115.76 | 25 | 10.26 | 2157 | 553 | 2.82 / 1470.62 | 1 | 1 |
4 | 13 | 407.80 | 55 | 13.21 | 1041 | 756 | 3.58 / 1471.37 | 1 | 1 |
5 | 8 | 0.04 | 160 | 14.19 | 377 | 856 | 4.43 / 1472.23 | 1 | 1 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 28 | 14.13 | 557 | 220 | 0.22 / 1460.67 | 1 | 1 |
2 | 12 | 1092.56 | 4 | 11.18 | 2157 | 96 | 0.32 / 1460.77 | 1 | 1 |
3 | 12 | 1981.12 | 140 | 7.90 | 3561 | 3938 | 4.26 / 1464.70 | 1 | 1 |
4 | 7 | 1972.20 | 25 | 9.97 | 3582 | 893 | 5.15 / 1465.60 | 1 | 1 |
5 | 13 | 539.20 | 55 | 13.15 | 1292 | 934 | 6.08 / 1466.53 | 1 | 1 |
6 | 13 | 83.56 | 55 | 14.01 | 542 | 418 | 6.50 / 1466.95 | 1 | 1 |
7 | 8 | -0.12 | 160 | 14.23 | 372 | 847 | 7.35 / 1467.80 | 1 | 243 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 27 | 14.12 | 541 | 206 | 0.21 / 1454.32 | 1 | 1 |
2 | 12 | 1129.88 | 140 | 5.53 | 2065 | 1599 | 1.80 / 1455.92 | 1 | 1 |
3 | 7 | 1136.08 | 25 | 9.90 | 2201 | 545 | 2.35 / 1456.46 | 1 | 1 |
4 | 13 | 1219.16 | 55 | 10.54 | 2338 | 1355 | 3.71 / 1457.82 | 1 | 1 |
5 | 13 | 1103.48 | 55 | 11.16 | 2125 | 1304 | 5.01 / 1459.12 | 1 | 1 |
6 | 13 | 128.00 | 55 | 13.84 | 608 | 463 | 5.47 / 1459.58 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.18 | 382 | 867 | 6.34 / 1460.45 | 1 | 243 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.28 | 28 | 14.11 | 556 | 220 | 0.22 / 1448.01 | 1 | 1 |
2 | 12 | 1126.32 | 140 | 5.53 | 2090 | 1618 | 1.84 / 1449.63 | 1 | 1 |
3 | 7 | 1131.64 | 25 | 9.78 | 2195 | 537 | 2.37 / 1450.17 | 1 | 1 |
4 | 13 | 1206.64 | 55 | 10.48 | 2301 | 1326 | 3.70 / 1451.49 | 1 | 1 |
5 | 13 | 1079.24 | 55 | 11.11 | 2109 | 1289 | 4.99 / 1452.78 | 1 | 1 |
6 | 13 | 129.36 | 55 | 13.84 | 611 | 465 | 5.45 / 1453.25 | 1 | 1 |
7 | 8 | 0.08 | 160 | 14.18 | 380 | 862 | 6.32 / 1454.11 | 1 | 207 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 28 | 14.15 | 547 | 217 | 0.22 / 1443.71 | 1 | 1 |
2 | 12 | 1113.32 | 140 | 7.12 | 2082 | 2075 | 2.29 / 1445.78 | 1 | 1 |
3 | 7 | 1105.60 | 25 | 10.40 | 2131 | 554 | 2.85 / 1446.34 | 1 | 1 |
4 | 13 | 265.32 | 55 | 13.56 | 825 | 615 | 3.46 / 1446.95 | 1 | 1 |
5 | 8 | 0.04 | 160 | 14.19 | 371 | 842 | 4.30 / 1447.79 | 1 | 1 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.08 | 27 | 14.10 | 555 | 211 | 0.21 / 1436.43 | 1 | 1 |
2 | 12 | 1143.08 | 4 | 11.15 | 2245 | 100 | 0.31 / 1436.53 | 1 | 1 |
3 | 12 | 1990.16 | 140 | 7.97 | 3562 | 3974 | 4.29 / 1440.50 | 1 | 1 |
4 | 7 | 1981.88 | 25 | 10.11 | 3581 | 905 | 5.19 / 1441.41 | 1 | 1 |
5 | 13 | 502.84 | 55 | 13.25 | 1231 | 897 | 6.09 / 1442.31 | 1 | 1 |
6 | 13 | 28.68 | 55 | 14.12 | 437 | 339 | 6.43 / 1442.64 | 1 | 1 |
7 | 8 | 0.12 | 160 | 14.24 | 371 | 845 | 7.27 / 1443.49 | 1 | 243 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 27 | 14.13 | 552 | 211 | 0.21 / 1429.98 | 1 | 1 |
2 | 12 | 1152.40 | 140 | 5.53 | 2078 | 1609 | 1.82 / 1431.58 | 1 | 1 |
3 | 7 | 1158.44 | 25 | 9.97 | 2233 | 557 | 2.38 / 1432.14 | 1 | 1 |
4 | 13 | 1239.76 | 55 | 10.75 | 2368 | 1400 | 3.78 / 1433.54 | 1 | 1 |
5 | 13 | 1117.56 | 55 | 11.32 | 2144 | 1335 | 5.11 / 1434.88 | 1 | 1 |
6 | 13 | 141.60 | 55 | 13.85 | 626 | 477 | 5.59 / 1435.35 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.18 | 381 | 864 | 6.45 / 1436.22 | 1 | 243 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 27 | 14.09 | 557 | 212 | 0.21 / 1423.59 | 1 | 1 |
2 | 12 | 1143.36 | 140 | 5.55 | 2076 | 1613 | 1.82 / 1425.20 | 1 | 1 |
3 | 7 | 1149.20 | 24 | 10.09 | 2227 | 539 | 2.36 / 1425.74 | 1 | 1 |
4 | 13 | 1235.48 | 55 | 10.55 | 2356 | 1367 | 3.73 / 1427.11 | 1 | 1 |
5 | 13 | 1118.60 | 55 | 11.18 | 2137 | 1314 | 5.05 / 1428.42 | 1 | 1 |
6 | 13 | 141.84 | 55 | 13.81 | 639 | 485 | 5.53 / 1428.91 | 1 | 1 |
7 | 8 | 0.08 | 160 | 14.18 | 377 | 855 | 6.39 / 1429.77 | 1 | 164 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 28 | 14.12 | 548 | 217 | 0.22 / 1418.62 | 1 | 1 |
2 | 3 | 963.84 | -1 | 15.12 | 0 | 0 | 0.00 / 1418.62 | 1 | 1 |
3 | 12 | 1147.92 | 140 | 6.94 | 2134 | 2073 | 2.29 / 1420.70 | 1 | 1 |
4 | 7 | 1141.56 | 25 | 10.34 | 2205 | 570 | 2.86 / 1421.27 | 1 | 1 |
5 | 13 | 587.44 | 55 | 12.96 | 1297 | 925 | 3.78 / 1422.19 | 1 | 1 |
6 | 13 | 47.40 | 55 | 14.04 | 465 | 359 | 4.14 / 1422.55 | 1 | 1 |
7 | 8 | -0.08 | 160 | 14.20 | 365 | 829 | 4.97 / 1423.38 | 1 | 243 |
Average= | 5.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 27 | 14.07 | 556 | 211 | 0.21 / 1411.33 | 1 | 1 |
2 | 12 | 1128.20 | 4 | 11.11 | 2217 | 99 | 0.31 / 1411.42 | 1 | 1 |
3 | 12 | 1988.64 | 140 | 7.89 | 3565 | 3938 | 4.25 / 1415.36 | 1 | 1 |
4 | 7 | 1980.08 | 25 | 10.26 | 3578 | 918 | 5.17 / 1416.28 | 1 | 1 |
5 | 13 | 517.76 | 55 | 13.25 | 1256 | 915 | 6.08 / 1417.20 | 1 | 1 |
6 | 13 | 37.76 | 55 | 14.09 | 460 | 356 | 6.44 / 1417.55 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.21 | 376 | 855 | 7.29 / 1418.41 | 1 | 243 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 28 | 14.11 | 526 | 208 | 0.21 / 1405.07 | 1 | 1 |
2 | 12 | 1114.28 | 140 | 5.54 | 2086 | 1618 | 1.83 / 1406.68 | 1 | 1 |
3 | 7 | 1120.04 | 25 | 10.17 | 2183 | 555 | 2.38 / 1407.24 | 1 | 1 |
4 | 13 | 1189.32 | 55 | 11.16 | 2264 | 1390 | 3.77 / 1408.63 | 1 | 1 |
5 | 13 | 804.48 | 55 | 12.44 | 1693 | 1158 | 4.93 / 1409.79 | 1 | 1 |
6 | 13 | 118.52 | 55 | 13.86 | 606 | 462 | 5.39 / 1410.25 | 1 | 1 |
7 | 8 | 0.16 | 160 | 14.15 | 382 | 865 | 6.26 / 1411.11 | 1 | 243 |
Average= | 5.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 25 | 14.07 | 548 | 193 | 0.19 / 1398.65 | 1 | 1 |
2 | 3 | 1070.36 | 2 | 11.46 | 2132 | 49 | 0.24 / 1398.70 | 1 | 1 |
3 | 3 | 1038.32 | 1 | 11.07 | 2064 | 23 | 0.26 / 1398.72 | 1 | 1 |
4 | 12 | 1145.52 | 140 | 5.55 | 2123 | 1650 | 1.91 / 1400.37 | 1 | 1 |
5 | 7 | 1151.92 | 25 | 10.04 | 2227 | 559 | 2.47 / 1400.93 | 1 | 1 |
6 | 13 | 1234.60 | 55 | 10.82 | 2353 | 1400 | 3.87 / 1402.33 | 1 | 1 |
7 | 13 | 969.68 | 55 | 12.04 | 1849 | 1224 | 5.10 / 1403.56 | 1 | 1 |
8 | 13 | 118.76 | 55 | 13.86 | 598 | 456 | 5.55 / 1404.01 | 1 | 1 |
9 | 8 | -0.04 | 160 | 14.16 | 374 | 847 | 6.40 / 1404.86 | 1 | 243 |
Average= | 5.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 37 | 14.17 | 518 | 272 | 0.27 / 1393.74 | 1 | 1 |
2 | 3 | 598.20 | -8 | 15.16 | 0 | 0 | 0.00 / 1393.74 | 1 | 1 |
3 | 3 | 859.68 | -3 | 15.15 | 0 | 0 | 0.00 / 1393.74 | 1 | 1 |
4 | 12 | 1139.68 | 140 | 7.03 | 2116 | 2083 | 2.35 / 1395.83 | 1 | 1 |
5 | 7 | 1134.08 | 25 | 10.43 | 2184 | 569 | 2.92 / 1396.39 | 1 | 1 |
6 | 13 | 566.16 | 55 | 13.19 | 1147 | 832 | 3.76 / 1397.23 | 1 | 1 |
7 | 13 | 89.84 | 55 | 13.95 | 532 | 408 | 4.16 / 1397.63 | 1 | 1 |
8 | 8 | -0.08 | 160 | 14.17 | 363 | 823 | 4.99 / 1398.46 | 1 | 243 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 27 | 14.12 | 522 | 199 | 0.20 / 1386.29 | 1 | 1 |
2 | 12 | 1118.88 | 4 | 11.12 | 2195 | 98 | 0.30 / 1386.39 | 1 | 1 |
3 | 12 | 1976.04 | 140 | 8.16 | 3550 | 4056 | 4.35 / 1390.45 | 1 | 1 |
4 | 7 | 1966.52 | 25 | 10.42 | 3544 | 923 | 5.28 / 1391.37 | 1 | 1 |
5 | 13 | 494.16 | 55 | 13.32 | 1212 | 888 | 6.16 / 1392.26 | 1 | 1 |
6 | 13 | 53.56 | 55 | 14.05 | 481 | 372 | 6.53 / 1392.63 | 1 | 1 |
7 | 8 | 0.08 | 160 | 14.20 | 371 | 843 | 7.38 / 1393.47 | 1 | 243 |
Average= | 5.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 27 | 14.12 | 549 | 209 | 0.21 / 1379.90 | 1 | 1 |
2 | 12 | 1133.00 | 140 | 5.56 | 2113 | 1645 | 1.85 / 1381.54 | 1 | 1 |
3 | 7 | 1139.96 | 24 | 10.45 | 2218 | 556 | 2.41 / 1382.10 | 1 | 1 |
4 | 13 | 1225.88 | 55 | 11.37 | 2295 | 1435 | 3.85 / 1383.53 | 1 | 1 |
5 | 13 | 952.60 | 55 | 12.30 | 1857 | 1256 | 5.10 / 1384.79 | 1 | 1 |
6 | 13 | 111.36 | 55 | 13.92 | 564 | 432 | 5.53 / 1385.22 | 1 | 1 |
7 | 8 | 0.08 | 160 | 14.16 | 385 | 872 | 6.41 / 1386.09 | 1 | 243 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 27 | 14.08 | 468 | 178 | 0.18 / 1373.15 | 1 | 1 |
2 | 10 | 1023.80 | 5 | 12.32 | 2046 | 126 | 0.30 / 1373.28 | 1 | 1 |
3 | 10 | 1056.60 | 3 | 12.55 | 2128 | 80 | 0.38 / 1373.36 | 1 | 1 |
4 | 3 | 1103.52 | 3 | 12.10 | 2195 | 80 | 0.46 / 1373.44 | 1 | 1 |
5 | 3 | 1034.68 | 1 | 11.30 | 2086 | 24 | 0.49 / 1373.46 | 1 | 1 |
6 | 12 | 1155.84 | 140 | 5.55 | 2138 | 1661 | 2.15 / 1375.12 | 1 | 1 |
7 | 7 | 1162.32 | 25 | 10.16 | 2247 | 571 | 2.72 / 1375.69 | 1 | 1 |
8 | 13 | 1231.36 | 55 | 11.18 | 2308 | 1419 | 4.14 / 1377.11 | 1 | 1 |
9 | 13 | 970.52 | 55 | 12.20 | 1880 | 1261 | 5.40 / 1378.38 | 1 | 1 |
10 | 13 | 120.24 | 55 | 13.87 | 600 | 458 | 5.86 / 1378.83 | 1 | 1 |
11 | 8 | 0.04 | 160 | 14.16 | 377 | 854 | 6.71 / 1379.69 | 1 | 243 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 27 | 14.15 | 521 | 199 | 0.20 / 1368.28 | 1 | 1 |
2 | 12 | 1135.36 | 140 | 7.15 | 2110 | 2112 | 2.31 / 1370.39 | 1 | 1 |
3 | 7 | 1128.28 | 25 | 10.44 | 2188 | 571 | 2.88 / 1370.96 | 1 | 1 |
4 | 13 | 540.52 | 55 | 13.16 | 1164 | 843 | 3.72 / 1371.80 | 1 | 1 |
5 | 13 | 41.60 | 55 | 14.04 | 448 | 346 | 4.07 / 1372.15 | 1 | 1 |
6 | 8 | 0.08 | 160 | 14.17 | 364 | 825 | 4.90 / 1372.98 | 1 | 243 |
Average= | 5.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 27 | 14.12 | 544 | 207 | 0.21 / 1360.87 | 1 | 1 |
2 | 12 | 1135.52 | 4 | 10.90 | 2222 | 97 | 0.30 / 1360.96 | 1 | 1 |
3 | 12 | 1976.88 | 140 | 8.11 | 3544 | 4024 | 4.33 / 1364.99 | 1 | 1 |
4 | 7 | 1967.60 | 25 | 10.39 | 3555 | 923 | 5.25 / 1365.91 | 1 | 1 |
5 | 13 | 593.16 | 55 | 13.18 | 1344 | 974 | 6.23 / 1366.89 | 1 | 1 |
6 | 13 | 45.56 | 55 | 14.07 | 466 | 361 | 6.59 / 1367.25 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.20 | 367 | 834 | 7.42 / 1368.08 | 1 | 243 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 27 | 14.06 | 550 | 209 | 0.21 / 1354.60 | 1 | 1 |
2 | 12 | 1153.04 | 140 | 5.54 | 2109 | 1636 | 1.84 / 1356.24 | 1 | 1 |
3 | 7 | 1158.24 | 25 | 10.26 | 2249 | 577 | 2.42 / 1356.82 | 1 | 1 |
4 | 13 | 1201.16 | 55 | 11.37 | 2315 | 1448 | 3.87 / 1358.26 | 1 | 1 |
5 | 13 | 800.60 | 55 | 12.66 | 1666 | 1160 | 5.03 / 1359.42 | 1 | 1 |
6 | 13 | 76.84 | 55 | 13.99 | 501 | 385 | 5.41 / 1359.81 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.17 | 375 | 850 | 6.26 / 1360.66 | 1 | 243 |
Average= | 5.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 27 | 14.05 | 546 | 207 | 0.21 / 1348.07 | 1 | 1 |
2 | 12 | 1144.36 | 140 | 5.56 | 2131 | 1659 | 1.87 / 1349.73 | 1 | 1 |
3 | 7 | 1151.24 | 25 | 10.19 | 2233 | 569 | 2.43 / 1350.29 | 1 | 1 |
4 | 13 | 1225.80 | 55 | 11.11 | 2353 | 1438 | 3.87 / 1351.73 | 1 | 1 |
5 | 13 | 1094.80 | 55 | 11.68 | 2129 | 1368 | 5.24 / 1353.10 | 1 | 1 |
6 | 13 | 107.68 | 55 | 13.89 | 562 | 429 | 5.67 / 1353.53 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.15 | 382 | 865 | 6.53 / 1354.39 | 1 | 243 |
Average= | 5.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 28 | 14.13 | 544 | 215 | 0.22 / 1343.69 | 1 | 1 |
2 | 12 | 1124.56 | 140 | 7.33 | 2103 | 2158 | 2.37 / 1345.85 | 1 | 1 |
3 | 7 | 1116.84 | 25 | 10.56 | 2160 | 570 | 2.94 / 1346.42 | 1 | 1 |
4 | 13 | 230.56 | 55 | 13.63 | 777 | 582 | 3.53 / 1347.00 | 1 | 1 |
5 | 8 | -0.04 | 160 | 14.13 | 381 | 861 | 4.39 / 1347.86 | 1 | 1 |
Average= | 5.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 27 | 14.10 | 530 | 202 | 0.20 / 1336.37 | 1 | 1 |
2 | 12 | 1101.32 | 4 | 10.96 | 2132 | 93 | 0.30 / 1336.46 | 1 | 1 |
3 | 12 | 1984.64 | 140 | 8.04 | 3570 | 4018 | 4.31 / 1340.48 | 1 | 1 |
4 | 7 | 1975.48 | 25 | 10.45 | 3559 | 930 | 5.24 / 1341.41 | 1 | 1 |
5 | 13 | 476.04 | 55 | 13.36 | 1177 | 865 | 6.11 / 1342.27 | 1 | 1 |
6 | 13 | 46.56 | 55 | 14.04 | 469 | 362 | 6.47 / 1342.64 | 1 | 1 |
7 | 8 | -0.04 | 160 | 14.17 | 369 | 837 | 7.31 / 1343.47 | 1 | 243 |
Average= | 5.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 27 | 14.09 | 519 | 197 | 0.20 / 1329.90 | 1 | 1 |
2 | 12 | 1154.12 | 140 | 5.55 | 2103 | 1634 | 1.83 / 1331.54 | 1 | 1 |
3 | 7 | 1159.92 | 25 | 10.29 | 2245 | 578 | 2.41 / 1332.11 | 1 | 1 |
4 | 13 | 1213.08 | 55 | 11.42 | 2306 | 1448 | 3.86 / 1333.56 | 1 | 1 |
5 | 13 | 1085.72 | 55 | 11.98 | 2054 | 1353 | 5.21 / 1334.92 | 1 | 1 |
6 | 13 | 97.60 | 55 | 13.94 | 535 | 410 | 5.62 / 1335.33 | 1 | 1 |
7 | 8 | 0.08 | 160 | 14.17 | 370 | 839 | 6.46 / 1336.17 | 1 | 243 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 27 | 14.07 | 545 | 207 | 0.21 / 1323.47 | 1 | 1 |
2 | 12 | 1132.44 | 140 | 5.55 | 2131 | 1656 | 1.86 / 1325.13 | 1 | 1 |
3 | 7 | 1138.08 | 25 | 10.26 | 2208 | 566 | 2.43 / 1325.69 | 1 | 1 |
4 | 13 | 1212.72 | 55 | 11.21 | 2314 | 1427 | 3.86 / 1327.12 | 1 | 1 |
5 | 13 | 1081.40 | 55 | 11.82 | 2083 | 1354 | 5.21 / 1328.48 | 1 | 1 |
6 | 13 | 98.20 | 55 | 13.93 | 521 | 399 | 5.61 / 1328.87 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.15 | 367 | 831 | 6.44 / 1329.71 | 1 | 169 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 27 | 14.11 | 530 | 202 | 0.20 / 1319.00 | 1 | 1 |
2 | 12 | 1125.16 | 140 | 7.30 | 2096 | 2142 | 2.34 / 1321.14 | 1 | 1 |
3 | 7 | 1118.20 | 25 | 10.56 | 2153 | 568 | 2.91 / 1321.71 | 1 | 1 |
4 | 13 | 380.80 | 55 | 13.38 | 986 | 726 | 3.64 / 1322.43 | 1 | 1 |
5 | 8 | 0.08 | 160 | 14.14 | 368 | 833 | 4.47 / 1323.27 | 1 | 1 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 27 | 14.07 | 543 | 206 | 0.21 / 1311.52 | 1 | 1 |
2 | 12 | 1117.04 | 4 | 10.82 | 2189 | 95 | 0.30 / 1311.61 | 1 | 1 |
3 | 12 | 1993.16 | 140 | 8.03 | 3564 | 4007 | 4.31 / 1315.62 | 1 | 1 |
4 | 7 | 1985.20 | 25 | 10.45 | 3589 | 938 | 5.25 / 1316.56 | 1 | 1 |
5 | 13 | 661.80 | 55 | 13.09 | 1469 | 1058 | 6.30 / 1317.61 | 1 | 1 |
6 | 13 | 53.48 | 55 | 14.06 | 466 | 360 | 6.66 / 1317.98 | 1 | 1 |
7 | 8 | 0.08 | 160 | 14.20 | 361 | 820 | 7.48 / 1318.80 | 1 | 243 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 27 | 14.06 | 540 | 205 | 0.20 / 1305.09 | 1 | 1 |
2 | 12 | 1130.20 | 140 | 5.54 | 2079 | 1612 | 1.82 / 1306.70 | 1 | 1 |
3 | 7 | 1135.88 | 25 | 10.31 | 2213 | 570 | 2.39 / 1307.27 | 1 | 1 |
4 | 13 | 1209.24 | 55 | 11.39 | 2280 | 1428 | 3.82 / 1308.70 | 1 | 1 |
5 | 13 | 1077.88 | 55 | 11.98 | 2053 | 1353 | 5.17 / 1310.05 | 1 | 1 |
6 | 13 | 104.24 | 55 | 13.91 | 552 | 422 | 5.59 / 1310.47 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.15 | 371 | 840 | 6.43 / 1311.31 | 1 | 243 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 27 | 14.05 | 541 | 205 | 0.21 / 1299.66 | 1 | 1 |
2 | 12 | 1145.32 | 140 | 5.99 | 2168 | 1818 | 2.02 / 1301.47 | 1 | 1 |
3 | 7 | 1148.76 | 25 | 10.40 | 2217 | 576 | 2.60 / 1302.05 | 1 | 1 |
4 | 13 | 1069.72 | 55 | 11.78 | 2063 | 1337 | 3.94 / 1303.39 | 1 | 1 |
5 | 13 | 311.32 | 55 | 13.51 | 894 | 664 | 4.60 / 1304.05 | 1 | 1 |
6 | 8 | 0.20 | 160 | 14.13 | 367 | 830 | 5.43 / 1304.88 | 1 | 2 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 27 | 14.11 | 523 | 199 | 0.20 / 1295.28 | 1 | 1 |
2 | 12 | 1124.76 | 140 | 7.62 | 2097 | 2237 | 2.44 / 1297.52 | 1 | 1 |
3 | 7 | 1117.44 | 24 | 10.83 | 2148 | 558 | 2.99 / 1298.07 | 1 | 1 |
4 | 13 | 232.12 | 55 | 13.64 | 755 | 566 | 3.56 / 1298.64 | 1 | 1 |
5 | 8 | 0.12 | 160 | 14.13 | 358 | 809 | 4.37 / 1299.45 | 1 | 1 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 27 | 14.06 | 539 | 205 | 0.20 / 1287.95 | 1 | 1 |
2 | 12 | 1099.40 | 4 | 10.81 | 2148 | 93 | 0.30 / 1288.05 | 1 | 1 |
3 | 12 | 1987.88 | 140 | 8.32 | 3554 | 4140 | 4.44 / 1292.19 | 1 | 1 |
4 | 7 | 1978.64 | 25 | 10.54 | 3581 | 944 | 5.38 / 1293.13 | 1 | 1 |
5 | 13 | 459.00 | 55 | 13.42 | 1114 | 822 | 6.20 / 1293.95 | 1 | 1 |
6 | 13 | 23.92 | 55 | 14.11 | 410 | 318 | 6.52 / 1294.27 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.21 | 356 | 809 | 7.33 / 1295.08 | 1 | 243 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 27 | 14.06 | 540 | 205 | 0.20 / 1281.68 | 1 | 1 |
2 | 12 | 1138.72 | 140 | 5.55 | 2143 | 1665 | 1.87 / 1283.35 | 1 | 1 |
3 | 7 | 1145.04 | 25 | 10.45 | 2220 | 580 | 2.45 / 1283.93 | 1 | 1 |
4 | 13 | 1213.08 | 55 | 11.43 | 2324 | 1461 | 3.91 / 1285.39 | 1 | 1 |
5 | 13 | 811.04 | 55 | 12.68 | 1685 | 1175 | 5.09 / 1286.56 | 1 | 1 |
6 | 13 | 70.72 | 55 | 14.00 | 464 | 357 | 5.44 / 1286.92 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.14 | 366 | 828 | 6.27 / 1287.75 | 1 | 243 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 27 | 14.03 | 546 | 207 | 0.21 / 1276.64 | 1 | 1 |
2 | 12 | 1130.96 | 140 | 6.41 | 2096 | 1881 | 2.09 / 1278.52 | 1 | 1 |
3 | 7 | 1127.56 | 25 | 10.51 | 2181 | 573 | 2.66 / 1279.09 | 1 | 1 |
4 | 13 | 755.04 | 55 | 12.62 | 1590 | 1104 | 3.76 / 1280.20 | 1 | 1 |
5 | 13 | 113.60 | 55 | 13.85 | 581 | 443 | 4.21 / 1280.64 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.11 | 372 | 840 | 5.05 / 1281.48 | 1 | 243 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 27 | 14.11 | 541 | 206 | 0.21 / 1272.17 | 1 | 1 |
2 | 12 | 1133.44 | 140 | 7.74 | 2121 | 2298 | 2.50 / 1274.47 | 1 | 1 |
3 | 7 | 1125.68 | 25 | 10.73 | 2174 | 583 | 3.09 / 1275.05 | 1 | 1 |
4 | 13 | 210.36 | 55 | 13.66 | 733 | 551 | 3.64 / 1275.60 | 1 | 1 |
5 | 8 | 0.08 | 160 | 14.11 | 368 | 831 | 4.47 / 1276.43 | 1 | 2 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 27 | 14.05 | 535 | 203 | 0.20 / 1265.12 | 1 | 1 |
2 | 12 | 1109.32 | 4 | 10.98 | 2166 | 95 | 0.30 / 1265.22 | 1 | 1 |
3 | 12 | 1977.96 | 140 | 8.40 | 3540 | 4163 | 4.46 / 1269.38 | 1 | 1 |
4 | 7 | 1968.28 | 25 | 10.55 | 3548 | 936 | 5.40 / 1270.31 | 1 | 1 |
5 | 13 | 457.56 | 55 | 13.41 | 1113 | 821 | 6.22 / 1271.13 | 1 | 1 |
6 | 8 | 0.12 | 160 | 14.20 | 364 | 827 | 7.04 / 1271.96 | 1 | 1 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 27 | 14.06 | 538 | 204 | 0.20 / 1258.96 | 1 | 1 |
2 | 12 | 1131.16 | 140 | 5.75 | 2146 | 1728 | 1.93 / 1260.69 | 1 | 1 |
3 | 7 | 1136.32 | 24 | 10.61 | 2213 | 564 | 2.50 / 1261.25 | 1 | 1 |
4 | 13 | 1139.28 | 55 | 11.71 | 2174 | 1400 | 3.90 / 1262.65 | 1 | 1 |
5 | 13 | 696.84 | 55 | 12.88 | 1498 | 1061 | 4.96 / 1263.71 | 1 | 1 |
6 | 13 | 59.20 | 55 | 13.97 | 484 | 372 | 5.33 / 1264.08 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.13 | 369 | 834 | 6.16 / 1264.92 | 1 | 243 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 27 | 14.01 | 532 | 201 | 0.20 / 1253.90 | 1 | 1 |
2 | 12 | 1137.16 | 140 | 6.38 | 2114 | 1888 | 2.09 / 1255.79 | 1 | 1 |
3 | 7 | 1132.96 | 25 | 10.48 | 2194 | 575 | 2.66 / 1256.36 | 1 | 1 |
4 | 13 | 858.64 | 55 | 12.36 | 1723 | 1171 | 3.84 / 1257.53 | 1 | 1 |
5 | 13 | 79.24 | 55 | 13.90 | 505 | 386 | 4.22 / 1257.92 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.09 | 371 | 836 | 5.06 / 1258.75 | 1 | 175 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 27 | 14.11 | 522 | 199 | 0.20 / 1249.49 | 1 | 1 |
2 | 12 | 1128.20 | 140 | 7.68 | 2108 | 2267 | 2.47 / 1251.76 | 1 | 1 |
3 | 7 | 1120.96 | 25 | 10.68 | 2173 | 580 | 3.05 / 1252.34 | 1 | 1 |
4 | 13 | 206.20 | 55 | 13.65 | 704 | 529 | 3.57 / 1252.87 | 1 | 1 |
5 | 8 | 0.08 | 160 | 14.07 | 368 | 828 | 4.40 / 1253.70 | 1 | 1 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 27 | 14.06 | 534 | 203 | 0.20 / 1242.34 | 1 | 1 |
2 | 12 | 1113.72 | 4 | 10.86 | 2176 | 95 | 0.30 / 1242.43 | 1 | 1 |
3 | 12 | 1984.52 | 140 | 7.84 | 3543 | 3889 | 4.19 / 1246.32 | 1 | 1 |
4 | 7 | 1975.80 | 24 | 10.61 | 3565 | 908 | 5.09 / 1247.23 | 1 | 1 |
5 | 13 | 517.48 | 55 | 13.27 | 1242 | 906 | 6.00 / 1248.13 | 1 | 1 |
6 | 13 | 34.32 | 55 | 14.08 | 432 | 335 | 6.33 / 1248.47 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.19 | 364 | 826 | 7.16 / 1249.29 | 1 | 243 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 28 | 14.02 | 534 | 210 | 0.21 / 1236.92 | 1 | 1 |
2 | 12 | 1118.92 | 140 | 5.98 | 2150 | 1800 | 2.01 / 1238.72 | 1 | 1 |
3 | 7 | 1122.40 | 25 | 10.57 | 2187 | 578 | 2.59 / 1239.30 | 1 | 1 |
4 | 13 | 1055.88 | 55 | 11.91 | 2047 | 1341 | 3.93 / 1240.64 | 1 | 1 |
5 | 13 | 304.88 | 55 | 13.50 | 882 | 655 | 4.58 / 1241.30 | 1 | 1 |
6 | 8 | 0.08 | 160 | 14.10 | 370 | 835 | 5.42 / 1242.13 | 1 | 1 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 28 | 13.98 | 538 | 211 | 0.21 / 1231.93 | 1 | 1 |
2 | 12 | 1132.08 | 140 | 6.53 | 2107 | 1926 | 2.14 / 1233.85 | 1 | 1 |
3 | 7 | 1127.56 | 25 | 10.53 | 2189 | 576 | 2.71 / 1234.43 | 1 | 1 |
4 | 13 | 720.92 | 55 | 12.64 | 1525 | 1060 | 3.77 / 1235.49 | 1 | 1 |
5 | 13 | 93.44 | 55 | 13.88 | 515 | 393 | 4.17 / 1235.88 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.09 | 369 | 832 | 5.00 / 1236.71 | 1 | 243 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 28 | 14.06 | 532 | 209 | 0.21 / 1227.51 | 1 | 1 |
2 | 12 | 1129.36 | 140 | 7.69 | 2113 | 2275 | 2.48 / 1229.78 | 1 | 1 |
3 | 7 | 1122.04 | 25 | 10.69 | 2169 | 580 | 3.06 / 1230.36 | 1 | 1 |
4 | 13 | 197.40 | 55 | 13.64 | 698 | 524 | 3.59 / 1230.89 | 1 | 1 |
5 | 8 | 0.04 | 160 | 14.07 | 368 | 828 | 4.42 / 1231.72 | 1 | 1 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 27 | 13.99 | 535 | 202 | 0.20 / 1220.24 | 1 | 1 |
2 | 12 | 1108.52 | 4 | 10.82 | 2169 | 94 | 0.30 / 1220.33 | 1 | 1 |
3 | 12 | 1970.92 | 140 | 7.49 | 3516 | 3687 | 3.98 / 1224.02 | 1 | 1 |
4 | 7 | 1961.96 | 25 | 10.49 | 3545 | 930 | 4.91 / 1224.95 | 1 | 1 |
5 | 13 | 732.08 | 55 | 12.93 | 1580 | 1124 | 6.04 / 1226.07 | 1 | 1 |
6 | 13 | 75.92 | 55 | 13.97 | 506 | 389 | 6.42 / 1226.46 | 1 | 1 |
7 | 8 | -0.08 | 160 | 14.15 | 372 | 842 | 7.27 / 1227.30 | 1 | 243 |
Average= | 5.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 28 | 14.01 | 528 | 207 | 0.21 / 1215.38 | 1 | 1 |
2 | 12 | 1088.84 | 140 | 6.53 | 2032 | 1858 | 2.06 / 1217.24 | 1 | 1 |
3 | 7 | 1083.64 | 25 | 10.61 | 2104 | 558 | 2.62 / 1217.79 | 1 | 1 |
4 | 13 | 702.48 | 55 | 12.70 | 1481 | 1034 | 3.66 / 1218.83 | 1 | 1 |
5 | 13 | 80.72 | 55 | 13.88 | 497 | 379 | 4.04 / 1219.21 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.08 | 366 | 825 | 4.86 / 1220.03 | 1 | 243 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 28 | 13.99 | 533 | 209 | 0.21 / 1210.58 | 1 | 1 |
2 | 12 | 1113.64 | 140 | 6.83 | 2057 | 1967 | 2.18 / 1212.55 | 1 | 1 |
3 | 7 | 1107.64 | 25 | 10.64 | 2146 | 571 | 2.75 / 1213.12 | 1 | 1 |
4 | 13 | 545.92 | 55 | 12.97 | 1253 | 894 | 3.64 / 1214.01 | 1 | 1 |
5 | 13 | 36.08 | 55 | 13.97 | 423 | 325 | 3.97 / 1214.33 | 1 | 1 |
6 | 8 | -0.04 | 160 | 14.06 | 372 | 837 | 4.80 / 1215.17 | 1 | 243 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 28 | 14.09 | 534 | 211 | 0.21 / 1206.16 | 1 | 1 |
2 | 12 | 1122.80 | 140 | 7.78 | 2114 | 2303 | 2.51 / 1208.46 | 1 | 1 |
3 | 7 | 1114.24 | 25 | 10.75 | 2150 | 578 | 3.09 / 1209.04 | 1 | 1 |
4 | 13 | 195.84 | 55 | 13.65 | 679 | 510 | 3.60 / 1209.55 | 1 | 1 |
5 | 8 | -0.04 | 160 | 14.06 | 364 | 819 | 4.42 / 1210.37 | 1 | 1 |
Average= | 5.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 27 | 14.01 | 533 | 202 | 0.20 / 1199.41 | 1 | 1 |
2 | 12 | 1118.88 | 4 | 10.72 | 2175 | 93 | 0.29 / 1199.50 | 1 | 1 |
3 | 12 | 1978.08 | 140 | 7.51 | 3541 | 3723 | 4.02 / 1203.23 | 1 | 1 |
4 | 7 | 1969.84 | 25 | 10.49 | 3549 | 931 | 4.95 / 1204.16 | 1 | 1 |
5 | 13 | 563.72 | 55 | 13.18 | 1314 | 953 | 5.90 / 1205.11 | 1 | 1 |
6 | 8 | 0.12 | 160 | 14.18 | 370 | 839 | 6.74 / 1205.95 | 1 | 1 |
Average= | 5.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 28 | 13.98 | 540 | 211 | 0.21 / 1194.36 | 1 | 1 |
2 | 12 | 1135.40 | 140 | 6.50 | 2095 | 1906 | 2.12 / 1196.27 | 1 | 1 |
3 | 7 | 1129.48 | 25 | 10.64 | 2187 | 582 | 2.70 / 1196.85 | 1 | 1 |
4 | 13 | 858.68 | 55 | 12.39 | 1717 | 1170 | 3.87 / 1198.02 | 1 | 1 |
5 | 13 | 71.76 | 55 | 13.94 | 467 | 358 | 4.23 / 1198.38 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.10 | 367 | 828 | 5.06 / 1199.21 | 1 | 243 |
Average= | 5.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 28 | 14.01 | 529 | 208 | 0.21 / 1189.94 | 1 | 1 |
2 | 12 | 1118.36 | 140 | 7.01 | 2077 | 2038 | 2.25 / 1191.98 | 1 | 1 |
3 | 7 | 1112.60 | 25 | 10.73 | 2159 | 579 | 2.83 / 1192.56 | 1 | 1 |
4 | 13 | 415.44 | 55 | 13.23 | 1044 | 760 | 3.58 / 1193.32 | 1 | 1 |
5 | 8 | -0.04 | 160 | 14.07 | 371 | 835 | 4.42 / 1194.15 | 1 | 1 |
Average= | 5.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.92 | 28 | 14.03 | 553 | 217 | 0.22 / 1185.37 | 1 | 1 |
2 | 12 | 1125.08 | 140 | 7.87 | 2102 | 2316 | 2.53 / 1187.68 | 1 | 1 |
3 | 7 | 1116.84 | 25 | 10.81 | 2159 | 583 | 3.12 / 1188.27 | 1 | 1 |
4 | 13 | 188.88 | 55 | 13.65 | 677 | 508 | 3.62 / 1188.77 | 1 | 1 |
5 | 8 | -0.12 | 160 | 14.06 | 366 | 823 | 4.45 / 1189.60 | 1 | 1 |
6 | 14 | -0.12 | 27 | 14.11 | 359 | 137 | 4.59 / 1189.73 | 1 | 243 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 28 | 13.98 | 536 | 210 | 0.21 / 1178.09 | 1 | 1 |
2 | 12 | 1100.08 | 4 | 10.86 | 2165 | 94 | 0.30 / 1178.18 | 1 | 1 |
3 | 12 | 1977.40 | 140 | 7.45 | 3529 | 3681 | 3.98 / 1181.86 | 1 | 1 |
4 | 7 | 1968.60 | 25 | 10.48 | 3558 | 932 | 4.92 / 1182.79 | 1 | 1 |
5 | 13 | 725.60 | 55 | 12.93 | 1562 | 1111 | 6.03 / 1183.90 | 1 | 1 |
6 | 13 | 86.48 | 55 | 13.94 | 528 | 405 | 6.43 / 1184.31 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.14 | 371 | 839 | 7.27 / 1185.15 | 1 | 243 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 28 | 13.96 | 522 | 204 | 0.20 / 1173.15 | 1 | 1 |
2 | 12 | 1121.96 | 140 | 6.75 | 2076 | 1962 | 2.17 / 1175.11 | 1 | 1 |
3 | 7 | 1115.36 | 25 | 10.73 | 2157 | 579 | 2.74 / 1175.69 | 1 | 1 |
4 | 13 | 671.48 | 55 | 12.71 | 1467 | 1026 | 3.77 / 1176.72 | 1 | 1 |
5 | 13 | 28.64 | 55 | 13.99 | 420 | 323 | 4.09 / 1177.04 | 1 | 1 |
6 | 8 | 0.12 | 160 | 14.08 | 371 | 836 | 4.93 / 1177.88 | 1 | 243 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 27 | 13.97 | 533 | 201 | 0.20 / 1168.70 | 1 | 1 |
2 | 12 | 1134.40 | 140 | 7.10 | 2101 | 2088 | 2.29 / 1170.79 | 1 | 1 |
3 | 7 | 1129.20 | 24 | 10.91 | 2182 | 571 | 2.86 / 1171.36 | 1 | 1 |
4 | 13 | 420.48 | 55 | 13.21 | 1055 | 767 | 3.63 / 1172.13 | 1 | 1 |
5 | 8 | 0.00 | 160 | 14.06 | 365 | 821 | 4.45 / 1172.95 | 1 | 1 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 27 | 14.03 | 537 | 203 | 0.20 / 1164.25 | 1 | 1 |
2 | 12 | 1127.12 | 140 | 8.00 | 2121 | 2376 | 2.58 / 1166.62 | 1 | 1 |
3 | 7 | 1119.20 | 24 | 11.00 | 2172 | 573 | 3.15 / 1167.20 | 1 | 1 |
4 | 13 | 166.44 | 55 | 13.67 | 645 | 485 | 3.64 / 1167.68 | 1 | 1 |
5 | 8 | 0.08 | 160 | 14.06 | 363 | 817 | 4.45 / 1168.50 | 1 | 1 |
Average= | 5.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 28 | 13.94 | 544 | 212 | 0.21 / 1157.09 | 1 | 1 |
2 | 12 | 1113.48 | 4 | 11.01 | 2161 | 95 | 0.31 / 1157.19 | 1 | 1 |
3 | 12 | 1967.40 | 140 | 7.54 | 3512 | 3707 | 4.01 / 1160.89 | 1 | 1 |
4 | 7 | 1959.12 | 25 | 10.49 | 3534 | 927 | 4.94 / 1161.82 | 1 | 1 |
5 | 13 | 684.40 | 55 | 13.02 | 1445 | 1035 | 5.98 / 1162.85 | 1 | 1 |
6 | 13 | 65.84 | 55 | 13.98 | 484 | 372 | 6.35 / 1163.23 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.15 | 362 | 820 | 7.17 / 1164.05 | 1 | 230 |
Average= | 5.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 28 | 13.96 | 541 | 211 | 0.21 / 1152.37 | 1 | 1 |
2 | 12 | 1116.56 | 140 | 7.09 | 2073 | 2058 | 2.27 / 1154.43 | 1 | 1 |
3 | 7 | 1109.48 | 24 | 11.01 | 2157 | 570 | 2.84 / 1155.00 | 1 | 1 |
4 | 13 | 384.44 | 55 | 13.27 | 996 | 727 | 3.57 / 1155.73 | 1 | 1 |
5 | 13 | 17.52 | 55 | 13.99 | 401 | 309 | 3.87 / 1156.04 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.05 | 374 | 841 | 4.72 / 1156.88 | 1 | 243 |
Average= | 5.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 27 | 13.96 | 548 | 207 | 0.21 / 1148.02 | 1 | 1 |
2 | 12 | 1114.12 | 140 | 7.41 | 2085 | 2163 | 2.37 / 1150.18 | 1 | 1 |
3 | 7 | 1106.08 | 25 | 10.95 | 2144 | 587 | 2.96 / 1150.77 | 1 | 1 |
4 | 13 | 222.32 | 55 | 13.55 | 750 | 559 | 3.52 / 1151.33 | 1 | 1 |
5 | 8 | 0.00 | 160 | 14.05 | 370 | 832 | 4.35 / 1152.16 | 1 | 1 |
Average= | 5.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 27 | 14.05 | 540 | 205 | 0.20 / 1143.55 | 1 | 1 |
2 | 12 | 1118.68 | 140 | 8.26 | 2100 | 2428 | 2.63 / 1145.97 | 1 | 1 |
3 | 7 | 1109.88 | 25 | 10.99 | 2134 | 586 | 3.22 / 1146.56 | 1 | 1 |
4 | 13 | 140.40 | 55 | 13.73 | 596 | 450 | 3.67 / 1147.01 | 1 | 1 |
5 | 8 | 0.08 | 160 | 14.07 | 357 | 804 | 4.47 / 1147.82 | 1 | 2 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 27 | 13.99 | 535 | 202 | 0.20 / 1136.82 | 1 | 1 |
2 | 12 | 1134.88 | 4 | 11.16 | 2217 | 99 | 0.30 / 1136.92 | 1 | 1 |
3 | 12 | 1954.00 | 140 | 8.13 | 3492 | 3975 | 4.28 / 1140.89 | 1 | 1 |
4 | 7 | 1944.20 | 25 | 10.57 | 3491 | 922 | 5.20 / 1141.81 | 1 | 1 |
5 | 13 | 329.20 | 55 | 13.49 | 939 | 697 | 5.89 / 1142.51 | 1 | 1 |
6 | 8 | -0.04 | 160 | 14.15 | 367 | 831 | 6.73 / 1143.34 | 1 | 1 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 27 | 13.99 | 537 | 203 | 0.20 / 1131.71 | 1 | 1 |
2 | 3 | 1019.00 | 1 | 11.06 | 2144 | 24 | 0.23 / 1131.73 | 1 | 1 |
3 | 12 | 1118.04 | 140 | 7.17 | 2080 | 2088 | 2.31 / 1133.82 | 1 | 1 |
4 | 7 | 1111.68 | 25 | 10.97 | 2149 | 589 | 2.90 / 1134.41 | 1 | 1 |
5 | 13 | 688.84 | 55 | 12.79 | 1477 | 1039 | 3.94 / 1135.45 | 1 | 1 |
6 | 13 | 54.04 | 55 | 13.94 | 462 | 354 | 4.30 / 1135.80 | 1 | 1 |
7 | 8 | -0.08 | 160 | 14.08 | 361 | 813 | 5.11 / 1136.62 | 1 | 243 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 27 | 13.99 | 539 | 204 | 0.20 / 1126.72 | 1 | 1 |
2 | 12 | 1130.00 | 140 | 7.49 | 2103 | 2205 | 2.41 / 1128.92 | 1 | 1 |
3 | 7 | 1123.12 | 25 | 10.95 | 2167 | 593 | 3.00 / 1129.52 | 1 | 1 |
4 | 13 | 515.76 | 55 | 13.08 | 1208 | 869 | 3.87 / 1130.38 | 1 | 1 |
5 | 13 | 23.08 | 55 | 14.02 | 402 | 310 | 4.18 / 1130.69 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.09 | 360 | 812 | 4.99 / 1131.51 | 1 | 243 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 27 | 14.09 | 532 | 202 | 0.20 / 1122.52 | 1 | 1 |
2 | 12 | 1130.68 | 120 | 8.20 | 2118 | 2084 | 2.29 / 1124.61 | 1 | 1 |
3 | 7 | 1123.92 | 24 | 11.13 | 2174 | 581 | 2.87 / 1125.19 | 1 | 1 |
4 | 13 | 256.56 | 48 | 13.55 | 778 | 506 | 3.37 / 1125.69 | 1 | 1 |
5 | 8 | 0.12 | 160 | 14.09 | 363 | 818 | 4.19 / 1126.51 | 1 | 1 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 27 | 14.03 | 535 | 203 | 0.20 / 1115.80 | 1 | 1 |
2 | 12 | 1125.24 | 4 | 11.28 | 2170 | 98 | 0.30 / 1115.90 | 1 | 1 |
3 | 12 | 1965.68 | 120 | 8.20 | 3502 | 3446 | 3.75 / 1119.35 | 1 | 1 |
4 | 7 | 1955.88 | 24 | 10.73 | 3515 | 905 | 4.65 / 1120.25 | 1 | 1 |
5 | 13 | 660.12 | 48 | 13.10 | 1456 | 916 | 5.57 / 1121.17 | 1 | 1 |
6 | 13 | 74.64 | 48 | 14.00 | 497 | 334 | 5.90 / 1121.50 | 1 | 1 |
7 | 8 | -0.04 | 160 | 14.18 | 362 | 821 | 6.72 / 1122.32 | 1 | 8 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 27 | 14.03 | 524 | 198 | 0.20 / 1111.04 | 1 | 1 |
2 | 12 | 1128.56 | 120 | 7.29 | 2099 | 1836 | 2.03 / 1112.88 | 1 | 1 |
3 | 7 | 1122.16 | 24 | 11.08 | 2175 | 578 | 2.61 / 1113.46 | 1 | 1 |
4 | 13 | 834.08 | 48 | 12.59 | 1689 | 1021 | 3.63 / 1114.48 | 1 | 1 |
5 | 13 | 71.16 | 48 | 13.96 | 455 | 305 | 3.94 / 1114.78 | 1 | 1 |
6 | 8 | -0.08 | 160 | 14.11 | 361 | 815 | 4.75 / 1115.60 | 1 | 5 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 27 | 14.06 | 519 | 197 | 0.20 / 1106.41 | 1 | 1 |
2 | 12 | 1123.52 | 120 | 7.65 | 2094 | 1922 | 2.12 / 1108.33 | 1 | 1 |
3 | 7 | 1117.40 | 24 | 11.18 | 2162 | 580 | 2.70 / 1108.91 | 1 | 1 |
4 | 13 | 537.28 | 48 | 13.12 | 1227 | 773 | 3.47 / 1109.68 | 1 | 1 |
5 | 13 | 88.72 | 48 | 13.89 | 515 | 343 | 3.82 / 1110.03 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.11 | 363 | 820 | 4.64 / 1110.85 | 1 | 26 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 27 | 14.15 | 520 | 199 | 0.20 / 1102.17 | 1 | 1 |
2 | 12 | 1123.04 | 120 | 8.72 | 2112 | 2210 | 2.41 / 1104.38 | 1 | 1 |
3 | 7 | 1115.08 | 25 | 11.19 | 2147 | 601 | 3.01 / 1104.98 | 1 | 1 |
4 | 13 | 183.28 | 48 | 13.72 | 649 | 427 | 3.44 / 1105.40 | 1 | 1 |
5 | 8 | 0.00 | 160 | 14.12 | 357 | 807 | 4.24 / 1106.21 | 1 | 1 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 24 | 14.13 | 530 | 180 | 0.18 / 1095.08 | 1 | 1 |
2 | 10 | 1020.72 | 3 | 12.36 | 2042 | 76 | 0.26 / 1095.16 | 1 | 1 |
3 | 3 | 1070.68 | 2 | 11.56 | 2122 | 49 | 0.30 / 1095.21 | 1 | 1 |
4 | 3 | 1028.08 | 1 | 11.05 | 2054 | 23 | 0.33 / 1095.23 | 1 | 1 |
5 | 12 | 1117.08 | 5 | 11.42 | 2177 | 124 | 0.45 / 1095.36 | 1 | 1 |
6 | 12 | 1944.44 | 120 | 9.39 | 3491 | 3934 | 4.39 / 1099.29 | 1 | 1 |
7 | 7 | 1934.08 | 24 | 10.90 | 3495 | 914 | 5.30 / 1100.20 | 1 | 1 |
8 | 13 | 382.76 | 48 | 13.53 | 1004 | 652 | 5.95 / 1100.86 | 1 | 1 |
9 | 13 | 39.60 | 48 | 14.11 | 431 | 292 | 6.24 / 1101.15 | 1 | 1 |
10 | 8 | 0.00 | 160 | 14.22 | 360 | 819 | 7.06 / 1101.97 | 1 | 243 |
Average= | 5.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 27 | 14.16 | 533 | 204 | 0.20 / 1084.78 | 1 | 1 |
2 | 12 | 1143.92 | 12 | 8.30 | 2167 | 216 | 0.42 / 1085.00 | 1 | 1 |
3 | 12 | 1977.16 | 170 | 5.86 | 3535 | 3522 | 3.94 / 1088.52 | 1 | 1 |
4 | 12 | 1968.48 | 120 | 7.85 | 3502 | 3299 | 7.24 / 1091.82 | 1 | 1 |
5 | 7 | 1960.00 | 25 | 10.77 | 3516 | 947 | 8.19 / 1092.76 | 1 | 1 |
6 | 13 | 726.96 | 48 | 13.06 | 1532 | 960 | 9.15 / 1093.72 | 1 | 1 |
7 | 13 | 91.40 | 48 | 13.96 | 527 | 353 | 9.50 / 1094.08 | 1 | 1 |
8 | 8 | 0.04 | 160 | 14.20 | 364 | 827 | 10.33 / 1094.90 | 1 | 3 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.48 | 27 | 14.10 | 540 | 206 | 0.21 / 1074.15 | 1 | 1 |
2 | 12 | 1103.04 | 14 | 8.39 | 2098 | 246 | 0.45 / 1074.40 | 1 | 1 |
3 | 12 | 1973.04 | 160 | 5.83 | 3469 | 3236 | 3.69 / 1077.64 | 1 | 1 |
4 | 12 | 1970.16 | 108 | 7.10 | 3629 | 2783 | 6.47 / 1080.42 | 1 | 1 |
5 | 7 | 1964.28 | 25 | 10.83 | 3526 | 955 | 7.43 / 1081.37 | 1 | 1 |
6 | 13 | 1527.44 | 48 | 12.12 | 2750 | 1600 | 9.03 / 1082.97 | 1 | 1 |
7 | 13 | 239.00 | 48 | 13.70 | 761 | 500 | 9.53 / 1083.47 | 1 | 1 |
8 | 13 | 45.48 | 48 | 14.13 | 411 | 279 | 9.80 / 1083.75 | 1 | 1 |
9 | 8 | 0.00 | 160 | 14.22 | 362 | 824 | 10.63 / 1084.58 | 1 | 243 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.88 | 27 | 14.14 | 534 | 204 | 0.20 / 1064.57 | 1 | 1 |
2 | 12 | 1106.80 | 14 | 8.55 | 2075 | 248 | 0.45 / 1064.81 | 1 | 1 |
3 | 12 | 1935.48 | 160 | 6.09 | 3439 | 3351 | 3.80 / 1068.16 | 1 | 1 |
4 | 12 | 1926.96 | 108 | 7.76 | 3427 | 2872 | 6.68 / 1071.04 | 1 | 1 |
5 | 7 | 1918.56 | 25 | 10.85 | 3441 | 933 | 7.61 / 1071.97 | 1 | 1 |
6 | 13 | 588.28 | 48 | 13.23 | 1311 | 833 | 8.44 / 1072.80 | 1 | 1 |
7 | 13 | 54.16 | 48 | 14.05 | 461 | 311 | 8.75 / 1073.11 | 1 | 1 |
8 | 8 | 0.04 | 160 | 14.20 | 368 | 836 | 9.59 / 1073.95 | 1 | 13 |
Average= | 5.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 27 | 14.18 | 540 | 207 | 0.21 / 1054.92 | 1 | 1 |
2 | 12 | 1128.64 | 14 | 8.61 | 2111 | 254 | 0.46 / 1055.18 | 1 | 1 |
3 | 12 | 1943.92 | 160 | 6.12 | 3456 | 3384 | 3.85 / 1058.56 | 1 | 1 |
4 | 12 | 1932.28 | 108 | 7.70 | 3441 | 2862 | 6.71 / 1061.42 | 1 | 1 |
5 | 7 | 1923.40 | 25 | 10.87 | 3451 | 938 | 7.64 / 1062.36 | 1 | 1 |
6 | 13 | 611.92 | 48 | 13.21 | 1353 | 858 | 8.50 / 1063.22 | 1 | 1 |
7 | 13 | 56.00 | 48 | 14.05 | 463 | 312 | 8.81 / 1063.53 | 1 | 1 |
8 | 8 | 0.04 | 160 | 14.20 | 365 | 829 | 9.64 / 1064.36 | 1 | 14 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 27 | 14.16 | 528 | 202 | 0.20 / 1044.70 | 1 | 1 |
2 | 12 | 1104.28 | 12 | 8.09 | 2070 | 201 | 0.40 / 1044.90 | 1 | 1 |
3 | 12 | 2015.64 | 160 | 5.83 | 3463 | 3230 | 3.63 / 1048.13 | 1 | 1 |
4 | 12 | 2022.76 | 60 | 6.68 | 3723 | 1492 | 5.13 / 1049.63 | 1 | 1 |
5 | 7 | 2020.40 | 25 | 10.82 | 3608 | 976 | 6.10 / 1050.60 | 1 | 1 |
6 | 13 | 1915.40 | 48 | 11.67 | 3385 | 1896 | 8.00 / 1052.50 | 1 | 1 |
7 | 13 | 828.84 | 48 | 13.04 | 1679 | 1051 | 9.05 / 1053.55 | 1 | 1 |
8 | 13 | 73.28 | 48 | 14.06 | 500 | 337 | 9.39 / 1053.89 | 1 | 1 |
9 | 8 | 0.08 | 160 | 14.25 | 364 | 830 | 10.22 / 1054.72 | 1 | 2 |
Average= | 5.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 27 | 14.20 | 535 | 205 | 0.21 / 1035.73 | 1 | 1 |
2 | 12 | 1102.32 | 12 | 8.17 | 2071 | 203 | 0.41 / 1035.93 | 1 | 1 |
3 | 12 | 2002.12 | 160 | 6.22 | 3551 | 3534 | 3.94 / 1039.46 | 1 | 1 |
4 | 12 | 2002.80 | 60 | 7.82 | 3547 | 1664 | 5.61 / 1041.13 | 1 | 1 |
5 | 7 | 1996.88 | 25 | 10.91 | 3582 | 977 | 6.58 / 1042.11 | 1 | 1 |
6 | 13 | 1022.20 | 48 | 12.80 | 1956 | 1202 | 7.79 / 1043.31 | 1 | 1 |
7 | 13 | 107.12 | 48 | 13.95 | 556 | 372 | 8.16 / 1043.68 | 1 | 1 |
8 | 8 | 0.00 | 160 | 14.23 | 361 | 822 | 8.98 / 1044.50 | 1 | 1 |
Average= | 5.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 27 | 14.18 | 528 | 202 | 0.20 / 1025.59 | 1 | 1 |
2 | 12 | 1123.80 | 12 | 7.13 | 2117 | 181 | 0.38 / 1025.77 | 1 | 1 |
3 | 12 | 2002.36 | 160 | 5.80 | 3306 | 3068 | 3.45 / 1028.84 | 1 | 1 |
4 | 12 | 2006.36 | 60 | 6.35 | 3726 | 1420 | 4.87 / 1030.26 | 1 | 1 |
5 | 7 | 2003.92 | 25 | 10.94 | 3606 | 986 | 5.86 / 1031.25 | 1 | 1 |
6 | 13 | 1887.44 | 48 | 11.78 | 3385 | 1914 | 7.77 / 1033.16 | 1 | 1 |
7 | 13 | 973.24 | 48 | 12.94 | 1874 | 1164 | 8.94 / 1034.32 | 1 | 1 |
8 | 13 | 122.20 | 48 | 13.98 | 560 | 376 | 9.31 / 1034.70 | 1 | 1 |
9 | 8 | 0.04 | 160 | 14.25 | 361 | 823 | 10.13 / 1035.52 | 1 | 1 |
Average= | 5.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.32 | 27 | 14.23 | 535 | 206 | 0.21 / 1017.54 | 1 | 1 |
2 | 12 | 1118.64 | 8 | 7.88 | 2096 | 132 | 0.34 / 1017.68 | 1 | 1 |
3 | 12 | 2001.88 | 130 | 6.85 | 3477 | 3096 | 3.43 / 1020.77 | 1 | 1 |
4 | 12 | 1990.00 | 60 | 7.24 | 3506 | 1523 | 4.96 / 1022.30 | 1 | 1 |
5 | 7 | 1980.96 | 25 | 10.98 | 3543 | 973 | 5.93 / 1023.27 | 1 | 1 |
6 | 13 | 697.24 | 48 | 13.16 | 1483 | 937 | 6.87 / 1024.21 | 1 | 1 |
7 | 13 | 91.52 | 48 | 13.99 | 532 | 357 | 7.22 / 1024.56 | 1 | 1 |
8 | 8 | 0.00 | 160 | 14.21 | 363 | 825 | 8.05 / 1025.39 | 1 | 2 |
Average= | 5.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 27 | 14.21 | 530 | 203 | 0.20 / 1007.95 | 1 | 1 |
2 | 12 | 1139.92 | 8 | 5.69 | 2066 | 94 | 0.30 / 1008.04 | 1 | 1 |
3 | 12 | 2009.08 | 130 | 5.76 | 2999 | 2246 | 2.54 / 1010.29 | 1 | 1 |
4 | 12 | 2017.20 | 60 | 5.80 | 3622 | 1260 | 3.80 / 1011.55 | 1 | 1 |
5 | 7 | 2019.64 | 25 | 10.90 | 3642 | 992 | 4.80 / 1012.54 | 1 | 1 |
6 | 13 | 1946.92 | 48 | 11.79 | 3458 | 1957 | 6.75 / 1014.50 | 1 | 1 |
7 | 13 | 1496.68 | 48 | 12.46 | 2700 | 1615 | 8.37 / 1016.11 | 1 | 1 |
8 | 13 | 155.40 | 48 | 13.92 | 619 | 414 | 8.78 / 1016.52 | 1 | 1 |
9 | 8 | 0.08 | 160 | 14.26 | 357 | 815 | 9.60 / 1017.34 | 1 | 1 |
Average= | 5.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 27 | 14.23 | 517 | 199 | 0.20 / 1000.59 | 1 | 1 |
2 | 12 | 1124.60 | 7 | 6.33 | 2168 | 96 | 0.29 / 1000.68 | 1 | 1 |
3 | 12 | 2003.24 | 85 | 6.74 | 3465 | 1985 | 2.28 / 1002.67 | 1 | 1 |
4 | 12 | 2002.56 | 45 | 7.14 | 3523 | 1132 | 3.41 / 1003.80 | 1 | 1 |
5 | 7 | 1997.76 | 25 | 10.85 | 3555 | 964 | 4.38 / 1004.76 | 1 | 1 |
6 | 13 | 1560.32 | 48 | 12.20 | 2801 | 1640 | 6.02 / 1006.40 | 1 | 1 |
7 | 13 | 254.92 | 48 | 13.71 | 787 | 518 | 6.53 / 1006.92 | 1 | 1 |
8 | 8 | 0.04 | 160 | 14.22 | 361 | 821 | 7.36 / 1007.74 | 1 | 1 |
Average= | 5.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 27 | 14.23 | 509 | 196 | 0.20 / 992.31 | 1 | 1 |
2 | 12 | 1114.84 | 7 | 5.73 | 2101 | 84 | 0.28 / 992.40 | 1 | 1 |
3 | 12 | 2004.00 | 85 | 5.80 | 3150 | 1553 | 1.83 / 993.95 | 1 | 1 |
4 | 12 | 2007.12 | 45 | 5.77 | 3570 | 927 | 2.76 / 994.88 | 1 | 1 |
5 | 7 | 2008.40 | 25 | 10.89 | 3620 | 986 | 3.75 / 995.86 | 1 | 1 |
6 | 13 | 1929.60 | 48 | 11.85 | 3406 | 1937 | 5.68 / 997.80 | 1 | 1 |
7 | 13 | 1205.80 | 48 | 12.75 | 2232 | 1366 | 7.05 / 999.17 | 1 | 1 |
8 | 13 | 134.96 | 48 | 13.97 | 597 | 400 | 7.45 / 999.57 | 1 | 1 |
9 | 8 | 0.04 | 160 | 14.26 | 360 | 821 | 8.27 / 1000.39 | 1 | 1 |
Average= | 5.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 27 | 14.20 | 537 | 206 | 0.21 / 985.04 | 1 | 1 |
2 | 12 | 1125.08 | 3 | 5.58 | 1417 | 24 | 0.23 / 985.06 | 1 | 1 |
3 | 12 | 2011.92 | 46 | 5.78 | 2771 | 737 | 0.97 / 985.80 | 1 | 1 |
4 | 12 | 2014.88 | 36 | 5.80 | 3378 | 705 | 1.67 / 986.50 | 1 | 1 |
5 | 7 | 2016.52 | 24 | 10.82 | 3620 | 940 | 2.61 / 987.44 | 1 | 1 |
6 | 13 | 1942.96 | 48 | 11.67 | 3467 | 1942 | 4.55 / 989.38 | 1 | 1 |
7 | 13 | 1337.48 | 48 | 12.54 | 2453 | 1477 | 6.03 / 990.86 | 1 | 1 |
8 | 13 | 187.04 | 48 | 13.88 | 662 | 441 | 6.47 / 991.30 | 1 | 1 |
9 | 8 | 0.04 | 160 | 14.23 | 358 | 815 | 7.29 / 992.12 | 1 | 1 |
Average= | 5.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 27 | 14.22 | 540 | 207 | 0.21 / 977.73 | 1 | 1 |
2 | 12 | 1123.28 | 3 | 5.61 | 1472 | 25 | 0.23 / 977.75 | 1 | 1 |
3 | 12 | 2004.48 | 46 | 5.80 | 2838 | 757 | 0.99 / 978.51 | 1 | 1 |
4 | 12 | 2007.48 | 36 | 5.78 | 3304 | 687 | 1.68 / 979.20 | 1 | 1 |
5 | 7 | 2009.12 | 24 | 10.84 | 3603 | 937 | 2.61 / 980.13 | 1 | 1 |
6 | 13 | 1934.44 | 48 | 11.75 | 3428 | 1933 | 4.55 / 982.07 | 1 | 1 |
7 | 13 | 1358.16 | 48 | 12.54 | 2471 | 1487 | 6.03 / 983.55 | 1 | 1 |
8 | 13 | 187.72 | 48 | 13.86 | 678 | 451 | 6.49 / 984.00 | 1 | 1 |
9 | 8 | 0.12 | 160 | 14.23 | 363 | 826 | 7.31 / 984.83 | 1 | 1 |
Average= | 5.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 27 | 14.23 | 508 | 195 | 0.20 / 971.25 | 1 | 1 |
2 | 12 | 2002.88 | 46 | 5.74 | 2561 | 676 | 0.87 / 971.93 | 1 | 1 |
3 | 7 | 2003.60 | 24 | 10.57 | 3581 | 908 | 1.78 / 972.84 | 1 | 1 |
4 | 13 | 1928.96 | 48 | 11.51 | 3439 | 1900 | 3.68 / 974.74 | 1 | 1 |
5 | 13 | 1349.04 | 48 | 12.45 | 2485 | 1485 | 5.16 / 976.22 | 1 | 1 |
6 | 13 | 199.28 | 48 | 13.82 | 705 | 468 | 5.63 / 976.69 | 1 | 1 |
7 | 8 | 0.08 | 160 | 14.22 | 365 | 830 | 6.46 / 977.52 | 1 | 1 |
Average= | 5.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 27 | 14.21 | 524 | 201 | 0.20 / 964.75 | 1 | 1 |
2 | 12 | 2006.48 | 46 | 5.77 | 2657 | 705 | 0.91 / 965.46 | 1 | 1 |
3 | 7 | 2007.96 | 24 | 10.71 | 3595 | 924 | 1.83 / 966.38 | 1 | 1 |
4 | 13 | 1934.60 | 48 | 11.59 | 3440 | 1914 | 3.74 / 968.29 | 1 | 1 |
5 | 13 | 1340.56 | 48 | 12.49 | 2471 | 1481 | 5.23 / 969.78 | 1 | 1 |
6 | 13 | 197.72 | 48 | 13.85 | 690 | 459 | 5.68 / 970.23 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.22 | 361 | 821 | 6.51 / 971.06 | 1 | 1 |
Average= | 5.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 27 | 14.22 | 530 | 203 | 0.20 / 958.23 | 1 | 1 |
2 | 12 | 2007.40 | 46 | 5.81 | 2861 | 765 | 0.97 / 959.00 | 1 | 1 |
3 | 7 | 2008.52 | 24 | 10.75 | 3596 | 928 | 1.90 / 959.92 | 1 | 1 |
4 | 13 | 1921.64 | 48 | 11.62 | 3432 | 1914 | 3.81 / 961.84 | 1 | 1 |
5 | 13 | 1218.88 | 48 | 12.62 | 2281 | 1382 | 5.19 / 963.22 | 1 | 1 |
6 | 13 | 225.92 | 48 | 13.77 | 762 | 504 | 5.70 / 963.72 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.21 | 364 | 828 | 6.52 / 964.55 | 1 | 1 |
Average= | 5.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 27 | 14.22 | 514 | 197 | 0.20 / 951.85 | 1 | 1 |
2 | 12 | 2004.48 | 46 | 5.76 | 2679 | 710 | 0.91 / 952.56 | 1 | 1 |
3 | 7 | 2005.12 | 24 | 10.72 | 3579 | 921 | 1.83 / 953.48 | 1 | 1 |
4 | 13 | 1922.04 | 48 | 11.60 | 3416 | 1902 | 3.73 / 955.38 | 1 | 1 |
5 | 13 | 1248.56 | 48 | 12.60 | 2314 | 1400 | 5.13 / 956.78 | 1 | 1 |
6 | 13 | 164.64 | 48 | 13.90 | 644 | 430 | 5.56 / 957.21 | 1 | 1 |
7 | 8 | 0.08 | 160 | 14.22 | 359 | 817 | 6.38 / 958.03 | 1 | 1 |
Average= | 5.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 27 | 14.23 | 516 | 198 | 0.20 / 945.27 | 1 | 1 |
2 | 12 | 2008.24 | 46 | 5.75 | 2636 | 697 | 0.90 / 945.96 | 1 | 1 |
3 | 7 | 2009.36 | 24 | 10.72 | 3574 | 920 | 1.81 / 946.88 | 1 | 1 |
4 | 13 | 1943.24 | 48 | 11.58 | 3457 | 1922 | 3.74 / 948.81 | 1 | 1 |
5 | 13 | 1387.20 | 48 | 12.46 | 2536 | 1517 | 5.25 / 950.32 | 1 | 1 |
6 | 13 | 235.80 | 48 | 13.77 | 769 | 508 | 5.76 / 950.83 | 1 | 1 |
7 | 8 | 0.08 | 160 | 14.21 | 361 | 821 | 6.58 / 951.65 | 1 | 1 |
Average= | 5.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 27 | 14.21 | 537 | 206 | 0.21 / 938.77 | 1 | 1 |
2 | 12 | 2001.92 | 46 | 5.77 | 2695 | 715 | 0.92 / 939.49 | 1 | 1 |
3 | 7 | 2002.44 | 24 | 10.80 | 3579 | 928 | 1.85 / 940.41 | 1 | 1 |
4 | 13 | 1920.52 | 48 | 11.68 | 3417 | 1916 | 3.76 / 942.33 | 1 | 1 |
5 | 13 | 1346.96 | 48 | 12.49 | 2477 | 1485 | 5.25 / 943.81 | 1 | 1 |
6 | 13 | 191.24 | 48 | 13.87 | 667 | 444 | 5.69 / 944.26 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.22 | 356 | 810 | 6.50 / 945.07 | 1 | 1 |
Average= | 5.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 27 | 14.27 | 508 | 196 | 0.20 / 932.29 | 1 | 1 |
2 | 12 | 2002.16 | 46 | 5.82 | 2851 | 763 | 0.96 / 933.05 | 1 | 1 |
3 | 7 | 2002.96 | 24 | 10.83 | 3586 | 932 | 1.89 / 933.99 | 1 | 1 |
4 | 13 | 1920.80 | 48 | 11.68 | 3417 | 1916 | 3.81 / 935.90 | 1 | 1 |
5 | 13 | 1186.52 | 48 | 12.67 | 2219 | 1350 | 5.16 / 937.25 | 1 | 1 |
6 | 13 | 222.80 | 48 | 13.81 | 733 | 486 | 5.64 / 937.74 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.21 | 364 | 828 | 6.47 / 938.57 | 1 | 1 |
Average= | 5.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 27 | 14.24 | 528 | 203 | 0.20 / 925.93 | 1 | 1 |
2 | 12 | 2003.92 | 46 | 5.78 | 2737 | 728 | 0.93 / 926.66 | 1 | 1 |
3 | 7 | 2004.48 | 24 | 10.81 | 3582 | 929 | 1.86 / 927.59 | 1 | 1 |
4 | 13 | 1911.24 | 48 | 11.71 | 3407 | 1915 | 3.78 / 929.50 | 1 | 1 |
5 | 13 | 1207.84 | 48 | 12.65 | 2259 | 1372 | 5.15 / 930.87 | 1 | 1 |
6 | 13 | 153.20 | 48 | 13.95 | 618 | 414 | 5.56 / 931.29 | 1 | 1 |
7 | 8 | 0.12 | 160 | 14.24 | 355 | 809 | 6.37 / 932.10 | 1 | 1 |
Average= | 5.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 27 | 14.24 | 526 | 202 | 0.20 / 919.51 | 1 | 1 |
2 | 12 | 2008.36 | 46 | 5.80 | 2844 | 759 | 0.96 / 920.26 | 1 | 1 |
3 | 7 | 2009.48 | 24 | 10.96 | 3594 | 945 | 1.91 / 921.21 | 1 | 1 |
4 | 13 | 1928.56 | 48 | 11.77 | 3422 | 1933 | 3.84 / 923.14 | 1 | 1 |
5 | 13 | 1223.92 | 48 | 12.68 | 2259 | 1375 | 5.21 / 924.52 | 1 | 1 |
6 | 13 | 144.44 | 48 | 14.00 | 597 | 401 | 5.62 / 924.92 | 1 | 1 |
7 | 8 | -0.08 | 160 | 14.25 | 354 | 807 | 6.42 / 925.73 | 1 | 1 |
Average= | 5.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 27 | 14.23 | 528 | 203 | 0.20 / 912.87 | 1 | 1 |
2 | 12 | 2004.40 | 46 | 5.81 | 2897 | 774 | 0.98 / 913.64 | 1 | 1 |
3 | 7 | 2005.72 | 24 | 10.94 | 3581 | 940 | 1.92 / 914.58 | 1 | 1 |
4 | 13 | 1933.04 | 48 | 11.78 | 3409 | 1928 | 3.84 / 916.51 | 1 | 1 |
5 | 13 | 1352.16 | 48 | 12.53 | 2473 | 1487 | 5.33 / 918.00 | 1 | 1 |
6 | 13 | 207.16 | 48 | 13.84 | 727 | 483 | 5.82 / 918.48 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.22 | 361 | 821 | 6.64 / 919.30 | 1 | 1 |
Average= | 5.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.24 | 27 | 14.25 | 519 | 200 | 0.20 / 906.43 | 1 | 1 |
2 | 12 | 2004.88 | 46 | 5.76 | 2778 | 736 | 0.94 / 907.17 | 1 | 1 |
3 | 7 | 2006.20 | 24 | 10.95 | 3567 | 937 | 1.87 / 908.11 | 1 | 1 |
4 | 13 | 1925.64 | 48 | 11.73 | 3428 | 1930 | 3.80 / 910.04 | 1 | 1 |
5 | 13 | 1190.04 | 48 | 12.71 | 2207 | 1346 | 5.15 / 911.38 | 1 | 1 |
6 | 13 | 205.24 | 48 | 13.86 | 703 | 468 | 5.62 / 911.85 | 1 | 1 |
7 | 8 | -0.12 | 160 | 14.22 | 358 | 815 | 6.43 / 912.67 | 1 | 1 |
Average= | 5.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 27 | 14.26 | 499 | 192 | 0.19 / 899.91 | 1 | 1 |
2 | 12 | 2006.04 | 46 | 5.80 | 2807 | 749 | 0.94 / 900.65 | 1 | 1 |
3 | 7 | 2006.88 | 24 | 10.97 | 3594 | 946 | 1.89 / 901.60 | 1 | 1 |
4 | 13 | 1921.60 | 48 | 11.78 | 3414 | 1930 | 3.82 / 903.53 | 1 | 1 |
5 | 13 | 1326.20 | 48 | 12.54 | 2437 | 1467 | 5.28 / 905.00 | 1 | 1 |
6 | 13 | 172.08 | 48 | 13.91 | 658 | 439 | 5.72 / 905.44 | 1 | 1 |
7 | 8 | 0.08 | 160 | 14.24 | 350 | 797 | 6.52 / 906.23 | 1 | 1 |
Average= | 5.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 27 | 14.24 | 505 | 194 | 0.19 / 893.48 | 1 | 1 |
2 | 12 | 2005.12 | 46 | 6.08 | 2929 | 819 | 1.01 / 894.30 | 1 | 1 |
3 | 7 | 2005.36 | 24 | 11.03 | 3591 | 951 | 1.96 / 895.25 | 1 | 1 |
4 | 13 | 1912.32 | 48 | 11.81 | 3387 | 1920 | 3.88 / 897.17 | 1 | 1 |
5 | 13 | 1166.28 | 48 | 12.72 | 2167 | 1323 | 5.21 / 898.49 | 1 | 1 |
6 | 13 | 173.72 | 48 | 13.92 | 636 | 425 | 5.63 / 898.91 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.23 | 351 | 799 | 6.43 / 899.71 | 1 | 1 |
Average= | 5.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 27 | 14.28 | 514 | 198 | 0.20 / 887.13 | 1 | 1 |
2 | 12 | 2004.76 | 46 | 7.05 | 2985 | 968 | 1.17 / 888.10 | 1 | 1 |
3 | 7 | 2003.68 | 24 | 10.97 | 3581 | 943 | 2.11 / 889.04 | 1 | 1 |
4 | 13 | 1885.96 | 48 | 11.84 | 3345 | 1901 | 4.01 / 890.94 | 1 | 1 |
5 | 13 | 962.28 | 48 | 12.93 | 1865 | 1157 | 5.17 / 892.10 | 1 | 1 |
6 | 13 | 125.36 | 48 | 14.03 | 548 | 369 | 5.54 / 892.47 | 1 | 1 |
7 | 8 | 0.08 | 160 | 14.22 | 357 | 812 | 6.35 / 893.28 | 1 | 1 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 27 | 14.28 | 518 | 200 | 0.20 / 880.75 | 1 | 1 |
2 | 12 | 2005.20 | 46 | 6.85 | 2983 | 940 | 1.14 / 881.69 | 1 | 1 |
3 | 7 | 2004.56 | 24 | 11.03 | 3570 | 945 | 2.08 / 882.64 | 1 | 1 |
4 | 13 | 1891.20 | 48 | 11.84 | 3324 | 1889 | 3.97 / 884.53 | 1 | 1 |
5 | 13 | 1007.28 | 48 | 12.86 | 1958 | 1209 | 5.18 / 885.73 | 1 | 1 |
6 | 13 | 135.68 | 48 | 13.98 | 600 | 403 | 5.59 / 886.14 | 1 | 1 |
7 | 8 | -0.04 | 160 | 14.23 | 350 | 797 | 6.38 / 886.93 | 1 | 1 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 27 | 14.26 | 515 | 198 | 0.20 / 874.36 | 1 | 1 |
2 | 12 | 2005.48 | 46 | 7.29 | 3086 | 1035 | 1.23 / 875.39 | 1 | 1 |
3 | 7 | 2004.72 | 24 | 11.01 | 3569 | 943 | 2.18 / 876.33 | 1 | 1 |
4 | 13 | 1890.12 | 48 | 11.84 | 3316 | 1885 | 4.06 / 878.22 | 1 | 1 |
5 | 13 | 976.36 | 48 | 12.93 | 1874 | 1163 | 5.22 / 879.38 | 1 | 1 |
6 | 13 | 132.40 | 48 | 14.02 | 569 | 383 | 5.61 / 879.77 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.24 | 345 | 786 | 6.39 / 880.55 | 1 | 1 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 27 | 14.29 | 497 | 192 | 0.19 / 867.93 | 1 | 1 |
2 | 12 | 2006.60 | 46 | 7.59 | 3016 | 1053 | 1.24 / 868.99 | 1 | 1 |
3 | 7 | 2005.36 | 24 | 11.02 | 3570 | 944 | 2.19 / 869.93 | 1 | 1 |
4 | 13 | 1880.76 | 48 | 11.83 | 3331 | 1891 | 4.08 / 871.82 | 1 | 1 |
5 | 13 | 953.32 | 48 | 12.94 | 1837 | 1141 | 5.22 / 872.96 | 1 | 1 |
6 | 13 | 121.36 | 48 | 14.02 | 571 | 384 | 5.61 / 873.35 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.23 | 356 | 811 | 6.42 / 874.16 | 1 | 1 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 27 | 14.31 | 494 | 191 | 0.19 / 861.46 | 1 | 1 |
2 | 12 | 2010.20 | 46 | 7.69 | 3065 | 1084 | 1.28 / 862.55 | 1 | 1 |
3 | 7 | 2009.08 | 24 | 10.97 | 3575 | 941 | 2.22 / 863.49 | 1 | 1 |
4 | 13 | 1898.56 | 48 | 11.80 | 3352 | 1899 | 4.11 / 865.39 | 1 | 1 |
5 | 13 | 979.52 | 48 | 12.91 | 1892 | 1172 | 5.29 / 866.56 | 1 | 1 |
6 | 13 | 121.84 | 48 | 14.00 | 575 | 386 | 5.67 / 866.95 | 1 | 1 |
7 | 8 | -0.08 | 160 | 14.23 | 350 | 797 | 6.47 / 867.74 | 1 | 1 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 26 | 14.25 | 522 | 193 | 0.19 / 854.98 | 1 | 1 |
2 | 12 | 2001.92 | 46 | 8.27 | 3182 | 1210 | 1.40 / 856.20 | 1 | 1 |
3 | 7 | 2000.32 | 24 | 10.96 | 3553 | 935 | 2.34 / 857.13 | 1 | 1 |
4 | 13 | 1885.20 | 48 | 11.83 | 3342 | 1898 | 4.24 / 859.03 | 1 | 1 |
5 | 13 | 902.44 | 48 | 12.99 | 1768 | 1102 | 5.34 / 860.13 | 1 | 1 |
6 | 13 | 107.88 | 48 | 14.07 | 526 | 355 | 5.69 / 860.49 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.25 | 345 | 787 | 6.48 / 861.27 | 1 | 1 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 27 | 14.28 | 518 | 200 | 0.20 / 848.85 | 1 | 1 |
2 | 12 | 2009.28 | 46 | 8.01 | 3111 | 1146 | 1.35 / 850.00 | 1 | 1 |
3 | 7 | 2007.84 | 24 | 10.97 | 3565 | 939 | 2.28 / 850.94 | 1 | 1 |
4 | 13 | 1746.04 | 48 | 12.01 | 3121 | 1799 | 4.08 / 852.74 | 1 | 1 |
5 | 13 | 673.20 | 48 | 13.21 | 1462 | 927 | 5.01 / 853.66 | 1 | 1 |
6 | 13 | 79.52 | 48 | 14.11 | 491 | 333 | 5.34 / 854.00 | 1 | 1 |
7 | 8 | -0.04 | 160 | 14.21 | 350 | 796 | 6.14 / 854.79 | 1 | 1 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 27 | 14.26 | 513 | 198 | 0.20 / 842.23 | 1 | 1 |
2 | 12 | 2015.04 | 46 | 7.93 | 3180 | 1160 | 1.36 / 843.39 | 1 | 1 |
3 | 7 | 2013.44 | 24 | 10.98 | 3577 | 943 | 2.30 / 844.33 | 1 | 1 |
4 | 13 | 1892.00 | 48 | 11.82 | 3342 | 1896 | 4.20 / 846.23 | 1 | 1 |
5 | 13 | 1101.40 | 48 | 12.76 | 2067 | 1266 | 5.46 / 847.49 | 1 | 1 |
6 | 13 | 102.48 | 48 | 14.06 | 530 | 358 | 5.82 / 847.85 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.22 | 353 | 803 | 6.62 / 848.65 | 1 | 1 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 26 | 14.28 | 526 | 195 | 0.20 / 835.82 | 1 | 1 |
2 | 12 | 2003.72 | 46 | 8.47 | 3189 | 1242 | 1.44 / 837.07 | 1 | 1 |
3 | 7 | 2002.16 | 24 | 11.06 | 3556 | 944 | 2.38 / 838.01 | 1 | 1 |
4 | 13 | 1872.52 | 48 | 11.86 | 3296 | 1876 | 4.26 / 839.89 | 1 | 1 |
5 | 13 | 770.92 | 48 | 13.13 | 1582 | 997 | 5.26 / 840.88 | 1 | 1 |
6 | 13 | 104.00 | 48 | 14.05 | 532 | 359 | 5.61 / 841.24 | 1 | 1 |
7 | 8 | 0.08 | 160 | 14.22 | 346 | 787 | 6.40 / 842.03 | 1 | 1 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 27 | 14.26 | 508 | 196 | 0.20 / 829.38 | 1 | 1 |
2 | 12 | 2007.92 | 46 | 8.50 | 3206 | 1254 | 1.45 / 830.64 | 1 | 1 |
3 | 7 | 2006.16 | 24 | 11.02 | 3580 | 947 | 2.40 / 831.58 | 1 | 1 |
4 | 13 | 1889.04 | 48 | 11.78 | 3365 | 1903 | 4.30 / 833.49 | 1 | 1 |
5 | 13 | 760.60 | 48 | 13.12 | 1569 | 988 | 5.29 / 834.48 | 1 | 1 |
6 | 13 | 105.60 | 48 | 14.03 | 540 | 364 | 5.65 / 834.84 | 1 | 1 |
7 | 8 | -0.04 | 160 | 14.21 | 347 | 789 | 6.44 / 835.63 | 1 | 1 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 26 | 14.28 | 515 | 191 | 0.19 / 823.18 | 1 | 1 |
2 | 12 | 2002.84 | 46 | 8.90 | 3261 | 1335 | 1.53 / 824.52 | 1 | 1 |
3 | 7 | 2000.32 | 24 | 11.03 | 3555 | 941 | 2.47 / 825.46 | 1 | 1 |
4 | 13 | 1732.24 | 48 | 12.00 | 3076 | 1772 | 4.24 / 827.23 | 1 | 1 |
5 | 13 | 622.52 | 48 | 13.27 | 1355 | 863 | 5.10 / 828.09 | 1 | 1 |
6 | 13 | 66.12 | 48 | 14.13 | 460 | 312 | 5.41 / 828.40 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.20 | 345 | 784 | 6.20 / 829.19 | 1 | 2 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 27 | 14.26 | 516 | 199 | 0.20 / 817.02 | 1 | 1 |
2 | 12 | 2004.20 | 46 | 8.87 | 3284 | 1340 | 1.54 / 818.36 | 1 | 1 |
3 | 7 | 2001.76 | 24 | 11.01 | 3553 | 939 | 2.48 / 819.30 | 1 | 1 |
4 | 13 | 1604.32 | 48 | 12.13 | 2884 | 1679 | 4.16 / 820.98 | 1 | 1 |
5 | 13 | 674.88 | 48 | 13.19 | 1443 | 914 | 5.07 / 821.89 | 1 | 1 |
6 | 13 | 71.52 | 48 | 14.10 | 468 | 317 | 5.39 / 822.21 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.20 | 344 | 782 | 6.17 / 822.99 | 1 | 1 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 27 | 14.30 | 498 | 192 | 0.19 / 810.80 | 1 | 1 |
2 | 12 | 2004.72 | 46 | 8.88 | 3283 | 1341 | 1.53 / 812.14 | 1 | 1 |
3 | 7 | 2002.60 | 24 | 11.00 | 3537 | 934 | 2.47 / 813.07 | 1 | 1 |
4 | 13 | 1874.72 | 48 | 11.81 | 3312 | 1878 | 4.34 / 814.95 | 1 | 1 |
5 | 13 | 501.16 | 48 | 13.41 | 1184 | 762 | 5.11 / 815.71 | 1 | 1 |
6 | 13 | 80.52 | 48 | 14.09 | 491 | 332 | 5.44 / 816.04 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.22 | 343 | 780 | 6.22 / 816.82 | 1 | 1 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 27 | 14.30 | 505 | 195 | 0.19 / 804.80 | 1 | 1 |
2 | 12 | 2003.92 | 46 | 9.15 | 3329 | 1401 | 1.60 / 806.20 | 1 | 1 |
3 | 7 | 2001.60 | 24 | 11.03 | 3543 | 938 | 2.53 / 807.14 | 1 | 1 |
4 | 13 | 1616.96 | 48 | 12.12 | 2899 | 1687 | 4.22 / 808.83 | 1 | 1 |
5 | 13 | 436.76 | 48 | 13.50 | 1061 | 688 | 4.91 / 809.52 | 1 | 1 |
6 | 13 | 56.84 | 48 | 14.14 | 446 | 303 | 5.21 / 809.82 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.20 | 345 | 784 | 5.99 / 810.60 | 1 | 2 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 27 | 14.26 | 512 | 197 | 0.20 / 798.49 | 1 | 1 |
2 | 12 | 2007.12 | 46 | 9.27 | 3291 | 1403 | 1.60 / 799.89 | 1 | 1 |
3 | 7 | 2004.76 | 24 | 11.03 | 3548 | 939 | 2.54 / 800.83 | 1 | 1 |
4 | 13 | 1872.00 | 48 | 11.82 | 3300 | 1872 | 4.41 / 802.71 | 1 | 1 |
5 | 13 | 577.16 | 48 | 13.31 | 1288 | 823 | 5.23 / 803.53 | 1 | 1 |
6 | 13 | 52.84 | 48 | 14.16 | 435 | 296 | 5.53 / 803.82 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.20 | 345 | 784 | 6.31 / 804.61 | 1 | 1 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 27 | 14.28 | 510 | 197 | 0.20 / 792.38 | 1 | 1 |
2 | 12 | 2004.64 | 46 | 9.32 | 3326 | 1426 | 1.62 / 793.81 | 1 | 1 |
3 | 7 | 2002.04 | 24 | 11.00 | 3546 | 936 | 2.56 / 794.75 | 1 | 1 |
4 | 13 | 1596.36 | 48 | 12.12 | 2868 | 1668 | 4.23 / 796.41 | 1 | 1 |
5 | 13 | 511.72 | 48 | 13.38 | 1202 | 772 | 5.00 / 797.19 | 1 | 1 |
6 | 13 | 68.88 | 48 | 14.11 | 471 | 319 | 5.32 / 797.51 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.19 | 347 | 788 | 6.11 / 798.29 | 1 | 1 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 27 | 14.27 | 521 | 201 | 0.20 / 786.46 | 1 | 1 |
2 | 12 | 2001.56 | 46 | 9.35 | 3345 | 1439 | 1.64 / 787.90 | 1 | 1 |
3 | 7 | 1998.64 | 24 | 11.02 | 3569 | 944 | 2.58 / 788.85 | 1 | 1 |
4 | 13 | 1596.56 | 48 | 12.13 | 2858 | 1664 | 4.25 / 790.51 | 1 | 1 |
5 | 13 | 374.92 | 48 | 13.58 | 968 | 631 | 4.88 / 791.14 | 1 | 1 |
6 | 13 | 47.68 | 48 | 14.20 | 397 | 271 | 5.15 / 791.41 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.21 | 341 | 775 | 5.92 / 792.19 | 1 | 1 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 27 | 14.29 | 511 | 197 | 0.20 / 780.26 | 1 | 1 |
2 | 12 | 2004.64 | 46 | 9.52 | 3434 | 1504 | 1.70 / 781.77 | 1 | 1 |
3 | 7 | 2002.00 | 24 | 11.06 | 3541 | 940 | 2.64 / 782.71 | 1 | 1 |
4 | 13 | 1730.00 | 48 | 11.99 | 3069 | 1766 | 4.41 / 784.47 | 1 | 1 |
5 | 13 | 453.60 | 48 | 13.47 | 1083 | 700 | 5.11 / 785.17 | 1 | 1 |
6 | 13 | 59.44 | 48 | 14.15 | 448 | 304 | 5.41 / 785.48 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.20 | 346 | 786 | 6.20 / 786.26 | 1 | 2 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 27 | 14.26 | 508 | 196 | 0.20 / 774.34 | 1 | 1 |
2 | 12 | 2001.84 | 46 | 9.67 | 3371 | 1499 | 1.70 / 775.84 | 1 | 1 |
3 | 7 | 1999.00 | 24 | 11.04 | 3540 | 938 | 2.63 / 776.77 | 1 | 1 |
4 | 13 | 1586.44 | 48 | 12.14 | 2850 | 1661 | 4.29 / 778.43 | 1 | 1 |
5 | 13 | 351.36 | 48 | 13.61 | 926 | 605 | 4.90 / 779.04 | 1 | 1 |
6 | 13 | 40.64 | 48 | 14.22 | 379 | 259 | 5.16 / 779.30 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.20 | 338 | 768 | 5.93 / 780.07 | 1 | 2 |
Average= | 5.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 27 | 14.29 | 497 | 192 | 0.19 / 768.28 | 1 | 1 |
2 | 12 | 1999.96 | 46 | 9.75 | 3373 | 1513 | 1.70 / 769.80 | 1 | 1 |
3 | 7 | 1996.48 | 24 | 11.10 | 3544 | 944 | 2.65 / 770.74 | 1 | 1 |
4 | 13 | 1585.44 | 48 | 12.17 | 2815 | 1644 | 4.29 / 772.38 | 1 | 1 |
5 | 13 | 450.60 | 48 | 13.48 | 1077 | 697 | 4.99 / 773.08 | 1 | 1 |
6 | 13 | 46.40 | 48 | 14.17 | 414 | 282 | 5.27 / 773.36 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.18 | 343 | 778 | 6.05 / 774.14 | 1 | 1 |
Average= | 5.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 26 | 14.31 | 508 | 189 | 0.19 / 762.10 | 1 | 1 |
2 | 12 | 2001.76 | 46 | 9.98 | 3409 | 1565 | 1.75 / 763.66 | 1 | 1 |
3 | 7 | 1998.68 | 24 | 11.03 | 3564 | 943 | 2.70 / 764.60 | 1 | 1 |
4 | 13 | 1726.48 | 48 | 12.00 | 3055 | 1760 | 4.46 / 766.36 | 1 | 1 |
5 | 13 | 410.68 | 48 | 13.52 | 1014 | 658 | 5.12 / 767.02 | 1 | 1 |
6 | 13 | 45.84 | 48 | 14.15 | 427 | 290 | 5.41 / 767.31 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.18 | 343 | 778 | 6.18 / 768.09 | 1 | 1 |
Average= | 5.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 27 | 14.28 | 496 | 191 | 0.19 / 756.05 | 1 | 1 |
2 | 12 | 2001.84 | 46 | 9.78 | 3397 | 1528 | 1.72 / 757.58 | 1 | 1 |
3 | 7 | 1998.92 | 24 | 11.01 | 3563 | 941 | 2.66 / 758.52 | 1 | 1 |
4 | 13 | 1726.68 | 48 | 11.99 | 3068 | 1766 | 4.43 / 760.29 | 1 | 1 |
5 | 13 | 322.80 | 48 | 13.64 | 875 | 573 | 5.00 / 760.86 | 1 | 1 |
6 | 13 | 32.28 | 48 | 14.19 | 395 | 269 | 5.27 / 761.13 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.18 | 342 | 776 | 6.04 / 761.91 | 1 | 2 |
Average= | 5.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 27 | 14.30 | 483 | 186 | 0.19 / 750.22 | 1 | 1 |
2 | 12 | 2000.56 | 46 | 9.93 | 3376 | 1542 | 1.73 / 751.76 | 1 | 1 |
3 | 7 | 1997.60 | 24 | 11.05 | 3523 | 934 | 2.66 / 752.70 | 1 | 1 |
4 | 13 | 1446.28 | 48 | 12.30 | 2615 | 1544 | 4.21 / 754.24 | 1 | 1 |
5 | 13 | 361.36 | 48 | 13.59 | 926 | 604 | 4.81 / 754.85 | 1 | 1 |
6 | 13 | 36.60 | 48 | 14.19 | 380 | 259 | 5.07 / 755.10 | 1 | 1 |
7 | 8 | -0.04 | 160 | 14.18 | 334 | 758 | 5.83 / 755.86 | 1 | 2 |
Average= | 5.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 27 | 14.28 | 489 | 189 | 0.19 / 744.39 | 1 | 1 |
2 | 12 | 2000.64 | 46 | 9.87 | 3416 | 1551 | 1.74 / 745.94 | 1 | 1 |
3 | 7 | 1997.44 | 24 | 11.05 | 3522 | 934 | 2.67 / 746.88 | 1 | 1 |
4 | 13 | 1445.72 | 48 | 12.30 | 2594 | 1531 | 4.21 / 748.41 | 1 | 1 |
5 | 13 | 351.64 | 48 | 13.60 | 932 | 608 | 4.81 / 749.02 | 1 | 1 |
6 | 13 | 34.20 | 48 | 14.20 | 386 | 263 | 5.08 / 749.28 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.18 | 333 | 756 | 5.83 / 750.04 | 1 | 3 |
Average= | 5.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 27 | 14.27 | 511 | 197 | 0.20 / 738.29 | 1 | 1 |
2 | 12 | 2001.80 | 46 | 10.04 | 3388 | 1565 | 1.76 / 739.86 | 1 | 1 |
3 | 7 | 1998.60 | 24 | 11.01 | 3532 | 933 | 2.69 / 740.79 | 1 | 1 |
4 | 13 | 1716.96 | 48 | 12.00 | 3032 | 1746 | 4.44 / 742.54 | 1 | 1 |
5 | 13 | 402.08 | 48 | 13.53 | 990 | 643 | 5.08 / 743.18 | 1 | 1 |
6 | 13 | 44.16 | 48 | 14.18 | 395 | 269 | 5.35 / 743.45 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.18 | 332 | 753 | 6.11 / 744.20 | 1 | 1 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 26 | 14.32 | 498 | 185 | 0.19 / 732.66 | 1 | 1 |
2 | 12 | 2002.52 | 46 | 10.09 | 3400 | 1578 | 1.76 / 734.24 | 1 | 1 |
3 | 7 | 1999.36 | 24 | 11.07 | 3539 | 940 | 2.70 / 735.18 | 1 | 1 |
4 | 13 | 1566.36 | 48 | 12.20 | 2778 | 1627 | 4.33 / 736.81 | 1 | 1 |
5 | 13 | 322.32 | 48 | 13.64 | 876 | 574 | 4.90 / 737.38 | 1 | 1 |
6 | 8 | 0.12 | 160 | 14.24 | 315 | 718 | 5.62 / 738.10 | 1 | 1 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 27 | 14.30 | 501 | 193 | 0.19 / 726.98 | 1 | 1 |
2 | 12 | 2000.24 | 46 | 10.14 | 3422 | 1596 | 1.79 / 728.57 | 1 | 1 |
3 | 7 | 1997.32 | 24 | 11.07 | 3538 | 940 | 2.73 / 729.51 | 1 | 1 |
4 | 13 | 1589.44 | 48 | 12.17 | 2818 | 1646 | 4.38 / 731.16 | 1 | 1 |
5 | 13 | 335.32 | 48 | 13.62 | 899 | 588 | 4.96 / 731.75 | 1 | 1 |
6 | 8 | 0.08 | 160 | 14.21 | 320 | 728 | 5.69 / 732.48 | 1 | 1 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 27 | 14.31 | 515 | 199 | 0.20 / 720.69 | 1 | 1 |
2 | 12 | 2015.36 | 46 | 10.11 | 3436 | 1598 | 1.80 / 722.29 | 1 | 1 |
3 | 7 | 2013.08 | 24 | 11.10 | 3566 | 950 | 2.75 / 723.24 | 1 | 1 |
4 | 13 | 1890.04 | 48 | 11.79 | 3346 | 1894 | 4.64 / 725.13 | 1 | 1 |
5 | 13 | 394.64 | 48 | 13.55 | 981 | 638 | 5.28 / 725.77 | 1 | 1 |
6 | 13 | 46.16 | 48 | 14.17 | 411 | 280 | 5.56 / 726.05 | 1 | 1 |
7 | 8 | -0.12 | 160 | 14.19 | 323 | 733 | 6.29 / 726.78 | 1 | 1 |
Average= | 5.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 26 | 14.29 | 502 | 187 | 0.19 / 715.01 | 1 | 1 |
2 | 12 | 2001.12 | 46 | 10.20 | 3432 | 1610 | 1.80 / 716.62 | 1 | 1 |
3 | 7 | 1997.68 | 24 | 11.07 | 3530 | 938 | 2.73 / 717.56 | 1 | 1 |
4 | 13 | 1571.48 | 48 | 12.18 | 2804 | 1639 | 4.37 / 719.20 | 1 | 1 |
5 | 13 | 294.32 | 48 | 13.68 | 823 | 540 | 4.91 / 719.74 | 1 | 1 |
6 | 8 | 0.12 | 160 | 14.19 | 332 | 754 | 5.67 / 720.49 | 1 | 1 |
Average= | 5.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.80 | 27 | 14.31 | 515 | 199 | 0.20 / 708.93 | 1 | 1 |
2 | 12 | 2004.80 | 46 | 10.19 | 3441 | 1613 | 1.81 / 710.54 | 1 | 1 |
3 | 7 | 2001.92 | 24 | 11.08 | 3563 | 947 | 2.76 / 711.49 | 1 | 1 |
4 | 13 | 1580.56 | 48 | 12.16 | 2821 | 1647 | 4.41 / 713.14 | 1 | 1 |
5 | 13 | 441.48 | 48 | 13.49 | 1058 | 685 | 5.09 / 713.82 | 1 | 1 |
6 | 13 | 23.08 | 48 | 14.21 | 371 | 253 | 5.34 / 714.08 | 1 | 1 |
7 | 8 | -0.08 | 160 | 14.18 | 330 | 749 | 6.09 / 714.82 | 1 | 1 |
Average= | 5.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 27 | 14.27 | 517 | 199 | 0.20 / 703.02 | 1 | 1 |
2 | 12 | 2001.96 | 46 | 10.19 | 3432 | 1609 | 1.81 / 704.62 | 1 | 1 |
3 | 7 | 1998.88 | 24 | 11.09 | 3547 | 944 | 2.75 / 705.57 | 1 | 1 |
4 | 13 | 1717.88 | 48 | 12.01 | 3035 | 1750 | 4.50 / 707.32 | 1 | 1 |
5 | 13 | 413.76 | 48 | 13.51 | 1020 | 661 | 5.16 / 707.98 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.21 | 331 | 753 | 5.92 / 708.73 | 1 | 1 |
Average= | 5.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 27 | 14.31 | 502 | 194 | 0.19 / 697.46 | 1 | 1 |
2 | 12 | 2008.40 | 46 | 10.16 | 3442 | 1609 | 1.80 / 699.07 | 1 | 1 |
3 | 7 | 2005.76 | 24 | 11.08 | 3550 | 944 | 2.75 / 700.01 | 1 | 1 |
4 | 13 | 1447.60 | 48 | 12.34 | 2582 | 1529 | 4.28 / 701.54 | 1 | 1 |
5 | 13 | 298.40 | 48 | 13.68 | 821 | 539 | 4.82 / 702.08 | 1 | 1 |
6 | 8 | 0.12 | 160 | 14.19 | 325 | 738 | 5.55 / 702.82 | 1 | 1 |
Average= | 5.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 26 | 14.31 | 497 | 185 | 0.18 / 691.63 | 1 | 1 |
2 | 12 | 2001.32 | 46 | 10.27 | 3468 | 1638 | 1.82 / 693.27 | 1 | 1 |
3 | 7 | 1998.32 | 24 | 11.11 | 3530 | 941 | 2.76 / 694.21 | 1 | 1 |
4 | 13 | 1575.36 | 48 | 12.17 | 2812 | 1643 | 4.41 / 695.85 | 1 | 1 |
5 | 13 | 415.96 | 48 | 13.52 | 1014 | 658 | 5.07 / 696.51 | 1 | 1 |
6 | 8 | 0.08 | 160 | 14.19 | 331 | 752 | 5.82 / 697.26 | 1 | 1 |
Average= | 5.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 26 | 14.31 | 508 | 189 | 0.19 / 686.16 | 1 | 1 |
2 | 12 | 2001.04 | 46 | 10.31 | 3435 | 1629 | 1.82 / 687.79 | 1 | 1 |
3 | 7 | 1998.32 | 24 | 11.07 | 3543 | 941 | 2.76 / 688.73 | 1 | 1 |
4 | 13 | 1444.80 | 48 | 12.29 | 2637 | 1556 | 4.32 / 690.29 | 1 | 1 |
5 | 13 | 185.60 | 48 | 13.88 | 641 | 427 | 4.74 / 690.71 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.19 | 323 | 733 | 5.48 / 691.45 | 1 | 1 |
Average= | 5.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 27 | 14.30 | 493 | 190 | 0.19 / 680.63 | 1 | 1 |
2 | 12 | 2014.68 | 46 | 10.29 | 3460 | 1638 | 1.83 / 682.26 | 1 | 1 |
3 | 7 | 2012.08 | 24 | 11.11 | 3547 | 946 | 2.77 / 683.21 | 1 | 1 |
4 | 13 | 1460.32 | 48 | 12.29 | 2629 | 1551 | 4.32 / 684.76 | 1 | 1 |
5 | 13 | 231.20 | 48 | 13.80 | 725 | 480 | 4.81 / 685.24 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.20 | 321 | 729 | 5.53 / 685.97 | 1 | 1 |
Average= | 5.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 26 | 14.29 | 505 | 188 | 0.19 / 674.92 | 1 | 1 |
2 | 12 | 2007.96 | 46 | 10.28 | 3460 | 1636 | 1.82 / 676.56 | 1 | 1 |
3 | 7 | 2005.08 | 24 | 11.11 | 3534 | 942 | 2.77 / 677.50 | 1 | 1 |
4 | 13 | 1593.80 | 48 | 12.17 | 2812 | 1643 | 4.41 / 679.14 | 1 | 1 |
5 | 13 | 325.24 | 48 | 13.66 | 857 | 562 | 4.97 / 679.70 | 1 | 1 |
6 | 8 | 0.16 | 160 | 14.18 | 323 | 733 | 5.70 / 680.44 | 1 | 1 |
Average= | 5.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 27 | 14.27 | 509 | 196 | 0.20 / 669.28 | 1 | 1 |
2 | 12 | 2005.28 | 46 | 10.35 | 3437 | 1636 | 1.83 / 670.92 | 1 | 1 |
3 | 7 | 2002.56 | 24 | 11.12 | 3543 | 946 | 2.78 / 671.86 | 1 | 1 |
4 | 13 | 1458.36 | 48 | 12.31 | 2616 | 1546 | 4.32 / 673.41 | 1 | 1 |
5 | 13 | 353.04 | 48 | 13.61 | 904 | 591 | 4.91 / 674.00 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.19 | 323 | 733 | 5.65 / 674.73 | 1 | 1 |
Average= | 5.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 26 | 14.30 | 497 | 185 | 0.18 / 663.61 | 1 | 1 |
2 | 12 | 1998.80 | 46 | 10.49 | 3437 | 1658 | 1.84 / 665.27 | 1 | 1 |
3 | 7 | 1995.36 | 24 | 11.20 | 3513 | 944 | 2.79 / 666.21 | 1 | 1 |
4 | 13 | 1555.88 | 48 | 12.22 | 2767 | 1623 | 4.41 / 667.83 | 1 | 1 |
5 | 13 | 249.00 | 48 | 13.77 | 751 | 496 | 4.91 / 668.33 | 1 | 1 |
6 | 8 | -0.04 | 160 | 14.17 | 333 | 755 | 5.66 / 669.09 | 1 | 1 |
Average= | 5.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 26 | 14.29 | 495 | 184 | 0.18 / 657.83 | 1 | 1 |
2 | 12 | 2000.36 | 46 | 10.36 | 3462 | 1650 | 1.83 / 659.48 | 1 | 1 |
3 | 7 | 1997.40 | 24 | 11.12 | 3532 | 943 | 2.78 / 660.42 | 1 | 1 |
4 | 13 | 1562.12 | 48 | 12.21 | 2773 | 1625 | 4.40 / 662.05 | 1 | 1 |
5 | 13 | 415.80 | 48 | 13.53 | 1009 | 655 | 5.06 / 662.70 | 1 | 1 |
6 | 8 | 0.24 | 160 | 14.19 | 318 | 722 | 5.78 / 663.42 | 1 | 1 |
Average= | 5.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 26 | 14.27 | 500 | 186 | 0.19 / 652.25 | 1 | 1 |
2 | 12 | 2000.96 | 46 | 10.34 | 3470 | 1650 | 1.84 / 653.90 | 1 | 1 |
3 | 7 | 1997.88 | 24 | 11.11 | 3537 | 943 | 2.78 / 654.84 | 1 | 1 |
4 | 13 | 1442.80 | 48 | 12.32 | 2580 | 1526 | 4.30 / 656.37 | 1 | 1 |
5 | 13 | 295.52 | 48 | 13.68 | 823 | 540 | 4.85 / 656.91 | 1 | 1 |
6 | 8 | -0.04 | 160 | 14.17 | 325 | 737 | 5.58 / 657.64 | 1 | 1 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 26 | 14.30 | 507 | 189 | 0.19 / 646.40 | 1 | 1 |
2 | 12 | 2003.80 | 46 | 10.41 | 3450 | 1652 | 1.84 / 648.06 | 1 | 1 |
3 | 7 | 2000.80 | 24 | 11.15 | 3516 | 941 | 2.78 / 649.00 | 1 | 1 |
4 | 13 | 1457.48 | 48 | 12.31 | 2625 | 1551 | 4.33 / 650.55 | 1 | 1 |
5 | 13 | 314.76 | 48 | 13.66 | 843 | 553 | 4.89 / 651.10 | 1 | 1 |
6 | 13 | 12.76 | 48 | 14.24 | 324 | 221 | 5.11 / 651.32 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.11 | 328 | 740 | 5.85 / 652.06 | 1 | 2 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 26 | 14.34 | 479 | 179 | 0.18 / 640.80 | 1 | 1 |
2 | 12 | 2005.20 | 46 | 10.31 | 3476 | 1649 | 1.83 / 642.45 | 1 | 1 |
3 | 7 | 2002.40 | 24 | 11.14 | 3538 | 946 | 2.77 / 643.39 | 1 | 1 |
4 | 13 | 1440.40 | 48 | 12.35 | 2566 | 1521 | 4.29 / 644.91 | 1 | 1 |
5 | 13 | 313.32 | 48 | 13.66 | 853 | 559 | 4.85 / 645.47 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.16 | 328 | 743 | 5.60 / 646.22 | 1 | 1 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 26 | 14.33 | 493 | 184 | 0.18 / 635.06 | 1 | 1 |
2 | 12 | 2006.00 | 46 | 10.31 | 3461 | 1641 | 1.83 / 636.70 | 1 | 1 |
3 | 7 | 2003.16 | 24 | 11.12 | 3538 | 944 | 2.77 / 637.65 | 1 | 1 |
4 | 13 | 1580.20 | 48 | 12.17 | 2815 | 1644 | 4.41 / 639.29 | 1 | 1 |
5 | 13 | 322.72 | 48 | 13.64 | 879 | 575 | 4.99 / 639.87 | 1 | 1 |
6 | 8 | -0.04 | 160 | 14.16 | 332 | 752 | 5.74 / 640.62 | 1 | 1 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 26 | 14.34 | 485 | 181 | 0.18 / 629.58 | 1 | 1 |
2 | 12 | 2000.72 | 46 | 10.33 | 3472 | 1650 | 1.83 / 631.23 | 1 | 1 |
3 | 7 | 1997.68 | 24 | 11.14 | 3515 | 940 | 2.77 / 632.17 | 1 | 1 |
4 | 13 | 1320.00 | 48 | 12.44 | 2403 | 1435 | 4.21 / 633.61 | 1 | 1 |
5 | 13 | 320.44 | 48 | 13.65 | 849 | 556 | 4.76 / 634.16 | 1 | 1 |
6 | 8 | 0.16 | 160 | 14.20 | 314 | 713 | 5.47 / 634.88 | 1 | 1 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 26 | 14.34 | 481 | 179 | 0.18 / 624.06 | 1 | 1 |
2 | 12 | 2001.00 | 46 | 10.51 | 3422 | 1654 | 1.83 / 625.71 | 1 | 1 |
3 | 7 | 1998.08 | 24 | 11.13 | 3515 | 939 | 2.77 / 626.65 | 1 | 1 |
4 | 13 | 1436.56 | 48 | 12.32 | 2586 | 1529 | 4.30 / 628.18 | 1 | 1 |
5 | 13 | 283.64 | 48 | 13.72 | 799 | 526 | 4.83 / 628.70 | 1 | 1 |
6 | 8 | 0.08 | 160 | 14.21 | 307 | 698 | 5.53 / 629.40 | 1 | 1 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 26 | 14.34 | 459 | 171 | 0.17 / 617.85 | 1 | 1 |
2 | 12 | 2004.12 | 46 | 10.44 | 3435 | 1650 | 1.82 / 619.50 | 1 | 1 |
3 | 7 | 2001.44 | 24 | 11.13 | 3509 | 937 | 2.76 / 620.44 | 1 | 1 |
4 | 13 | 1869.08 | 48 | 11.80 | 3300 | 1869 | 4.63 / 622.31 | 1 | 1 |
5 | 13 | 380.76 | 48 | 13.58 | 947 | 617 | 5.24 / 622.93 | 1 | 1 |
6 | 13 | 38.44 | 48 | 14.21 | 361 | 246 | 5.49 / 623.17 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.17 | 311 | 705 | 6.20 / 623.88 | 1 | 1 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 26 | 14.33 | 476 | 177 | 0.18 / 612.18 | 1 | 1 |
2 | 12 | 2002.04 | 46 | 10.41 | 3469 | 1661 | 1.84 / 613.84 | 1 | 1 |
3 | 7 | 1998.88 | 24 | 11.18 | 3537 | 949 | 2.79 / 614.79 | 1 | 1 |
4 | 13 | 1574.52 | 48 | 12.18 | 2810 | 1643 | 4.43 / 616.43 | 1 | 1 |
5 | 13 | 300.52 | 48 | 13.70 | 830 | 546 | 4.98 / 616.98 | 1 | 1 |
6 | 8 | 0.12 | 160 | 14.20 | 310 | 704 | 5.68 / 617.68 | 1 | 1 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 26 | 14.32 | 500 | 186 | 0.19 / 606.52 | 1 | 1 |
2 | 12 | 2005.36 | 46 | 10.55 | 3444 | 1671 | 1.86 / 608.19 | 1 | 1 |
3 | 7 | 2002.32 | 24 | 11.17 | 3528 | 946 | 2.80 / 609.14 | 1 | 1 |
4 | 13 | 1576.00 | 48 | 12.19 | 2806 | 1642 | 4.45 / 610.78 | 1 | 1 |
5 | 13 | 285.56 | 48 | 13.71 | 797 | 524 | 4.97 / 611.31 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.21 | 305 | 693 | 5.66 / 612.00 | 1 | 1 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.52 | 26 | 14.36 | 487 | 182 | 0.18 / 600.66 | 1 | 1 |
2 | 12 | 2001.68 | 46 | 10.58 | 3430 | 1669 | 1.85 / 602.33 | 1 | 1 |
3 | 7 | 1998.64 | 24 | 11.20 | 3529 | 949 | 2.80 / 603.28 | 1 | 1 |
4 | 13 | 1450.76 | 48 | 12.33 | 2567 | 1519 | 4.32 / 604.80 | 1 | 1 |
5 | 13 | 317.72 | 48 | 13.67 | 848 | 556 | 4.88 / 605.35 | 1 | 1 |
6 | 13 | 31.32 | 48 | 14.21 | 380 | 259 | 5.13 / 605.61 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.17 | 320 | 726 | 5.86 / 606.34 | 1 | 1 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 26 | 14.35 | 487 | 182 | 0.18 / 594.64 | 1 | 1 |
2 | 12 | 2002.24 | 46 | 10.51 | 3436 | 1661 | 1.84 / 596.30 | 1 | 1 |
3 | 7 | 1999.20 | 24 | 11.18 | 3521 | 945 | 2.79 / 597.25 | 1 | 1 |
4 | 13 | 1719.08 | 48 | 11.99 | 3024 | 1740 | 4.53 / 598.99 | 1 | 1 |
5 | 13 | 285.20 | 48 | 13.73 | 800 | 527 | 5.06 / 599.52 | 1 | 1 |
6 | 13 | 26.48 | 48 | 14.22 | 367 | 250 | 5.31 / 599.77 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.18 | 313 | 710 | 6.02 / 600.48 | 1 | 1 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 26 | 14.34 | 486 | 181 | 0.18 / 589.01 | 1 | 1 |
2 | 12 | 2002.56 | 46 | 10.53 | 3429 | 1661 | 1.84 / 590.67 | 1 | 1 |
3 | 7 | 1999.28 | 24 | 11.18 | 3522 | 945 | 2.79 / 591.62 | 1 | 1 |
4 | 13 | 1554.92 | 48 | 12.20 | 2758 | 1615 | 4.40 / 593.23 | 1 | 1 |
5 | 13 | 272.24 | 48 | 13.74 | 780 | 514 | 4.92 / 593.75 | 1 | 1 |
6 | 8 | 0.16 | 160 | 14.21 | 314 | 714 | 5.63 / 594.46 | 1 | 1 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 26 | 14.37 | 472 | 176 | 0.18 / 583.56 | 1 | 1 |
2 | 12 | 2003.40 | 46 | 10.55 | 3430 | 1665 | 1.84 / 585.23 | 1 | 1 |
3 | 7 | 2000.16 | 24 | 11.19 | 3514 | 944 | 2.78 / 586.17 | 1 | 1 |
4 | 13 | 1435.32 | 48 | 12.33 | 2572 | 1522 | 4.31 / 587.70 | 1 | 1 |
5 | 13 | 205.72 | 48 | 13.86 | 663 | 441 | 4.75 / 588.14 | 1 | 1 |
6 | 8 | 0.08 | 160 | 14.22 | 305 | 694 | 5.44 / 588.83 | 1 | 1 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 26 | 14.35 | 460 | 172 | 0.17 / 577.94 | 1 | 1 |
2 | 12 | 2001.32 | 46 | 10.65 | 3422 | 1676 | 1.85 / 579.61 | 1 | 1 |
3 | 7 | 1998.08 | 24 | 11.21 | 3500 | 942 | 2.79 / 580.55 | 1 | 1 |
4 | 13 | 1577.52 | 48 | 12.15 | 2809 | 1638 | 4.43 / 582.19 | 1 | 1 |
5 | 13 | 270.24 | 48 | 13.74 | 773 | 510 | 4.94 / 582.70 | 1 | 1 |
6 | 8 | 0.16 | 160 | 14.21 | 302 | 687 | 5.62 / 583.39 | 1 | 1 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 26 | 14.36 | 463 | 173 | 0.17 / 572.31 | 1 | 1 |
2 | 12 | 2002.80 | 46 | 10.57 | 3430 | 1668 | 1.84 / 573.98 | 1 | 1 |
3 | 7 | 2000.12 | 24 | 11.21 | 3513 | 945 | 2.79 / 574.92 | 1 | 1 |
4 | 13 | 1285.92 | 48 | 12.50 | 2318 | 1391 | 4.18 / 576.31 | 1 | 1 |
5 | 13 | 301.32 | 48 | 13.71 | 807 | 531 | 4.71 / 576.84 | 1 | 1 |
6 | 13 | 25.28 | 48 | 14.24 | 340 | 232 | 4.94 / 577.08 | 1 | 1 |
7 | 8 | -0.04 | 160 | 14.17 | 304 | 689 | 5.63 / 577.76 | 1 | 1 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 26 | 14.37 | 481 | 180 | 0.18 / 566.71 | 1 | 1 |
2 | 12 | 2000.56 | 46 | 10.63 | 3425 | 1675 | 1.85 / 568.39 | 1 | 1 |
3 | 7 | 1997.16 | 24 | 11.21 | 3511 | 945 | 2.80 / 569.33 | 1 | 1 |
4 | 13 | 1551.20 | 48 | 12.22 | 2725 | 1598 | 4.40 / 570.93 | 1 | 1 |
5 | 13 | 290.52 | 48 | 13.71 | 811 | 534 | 4.93 / 571.46 | 1 | 1 |
6 | 8 | 0.16 | 160 | 14.22 | 295 | 671 | 5.60 / 572.14 | 1 | 1 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 26 | 14.36 | 477 | 178 | 0.18 / 561.13 | 1 | 1 |
2 | 12 | 2002.32 | 46 | 10.46 | 3461 | 1665 | 1.84 / 562.80 | 1 | 1 |
3 | 7 | 1999.52 | 24 | 11.25 | 3528 | 953 | 2.80 / 563.75 | 1 | 1 |
4 | 13 | 1445.36 | 48 | 12.34 | 2592 | 1535 | 4.33 / 565.29 | 1 | 1 |
5 | 13 | 304.76 | 48 | 13.71 | 825 | 543 | 4.87 / 565.83 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.20 | 310 | 704 | 5.58 / 566.53 | 1 | 1 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.72 | 26 | 14.35 | 484 | 181 | 0.18 / 555.33 | 1 | 1 |
2 | 12 | 2002.40 | 46 | 10.70 | 3425 | 1686 | 1.87 / 557.02 | 1 | 1 |
3 | 7 | 1999.12 | 24 | 11.28 | 3526 | 955 | 2.82 / 557.97 | 1 | 1 |
4 | 13 | 1428.52 | 48 | 12.36 | 2551 | 1513 | 4.33 / 559.49 | 1 | 1 |
5 | 13 | 297.56 | 48 | 13.72 | 818 | 539 | 4.87 / 560.02 | 1 | 1 |
6 | 13 | 25.72 | 48 | 14.28 | 333 | 228 | 5.10 / 560.25 | 1 | 1 |
7 | 8 | -0.08 | 160 | 14.18 | 309 | 701 | 5.80 / 560.95 | 1 | 2 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 26 | 14.36 | 472 | 176 | 0.18 / 549.65 | 1 | 1 |
2 | 12 | 2002.36 | 46 | 10.68 | 3421 | 1681 | 1.86 / 551.33 | 1 | 1 |
3 | 7 | 1999.20 | 24 | 11.27 | 3517 | 951 | 2.81 / 552.28 | 1 | 1 |
4 | 13 | 1567.60 | 48 | 12.21 | 2793 | 1637 | 4.45 / 553.92 | 1 | 1 |
5 | 13 | 281.20 | 48 | 13.74 | 798 | 526 | 4.97 / 554.44 | 1 | 1 |
6 | 8 | 0.20 | 160 | 14.22 | 312 | 710 | 5.68 / 555.15 | 1 | 1 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 26 | 14.38 | 492 | 184 | 0.18 / 543.68 | 1 | 1 |
2 | 12 | 2003.44 | 46 | 10.65 | 3426 | 1678 | 1.86 / 545.36 | 1 | 1 |
3 | 7 | 2000.40 | 24 | 11.27 | 3532 | 955 | 2.82 / 546.32 | 1 | 1 |
4 | 13 | 1554.52 | 48 | 12.23 | 2736 | 1606 | 4.42 / 547.92 | 1 | 1 |
5 | 13 | 400.40 | 48 | 13.57 | 972 | 633 | 5.06 / 548.56 | 1 | 1 |
6 | 13 | 40.04 | 48 | 14.25 | 353 | 241 | 5.30 / 548.80 | 1 | 1 |
7 | 8 | 0.04 | 160 | 14.20 | 296 | 673 | 5.97 / 549.47 | 1 | 1 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 26 | 14.39 | 467 | 175 | 0.17 / 538.19 | 1 | 1 |
2 | 12 | 1999.88 | 46 | 10.73 | 3416 | 1686 | 1.86 / 539.87 | 1 | 1 |
3 | 7 | 1996.84 | 24 | 11.31 | 3525 | 957 | 2.82 / 540.83 | 1 | 1 |
4 | 13 | 1296.52 | 48 | 12.52 | 2354 | 1415 | 4.23 / 542.25 | 1 | 1 |
5 | 13 | 320.72 | 48 | 13.71 | 845 | 556 | 4.79 / 542.80 | 1 | 1 |
6 | 8 | 0.08 | 160 | 14.22 | 307 | 698 | 5.49 / 543.50 | 1 | 1 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 26 | 14.34 | 494 | 184 | 0.18 / 532.27 | 1 | 1 |
2 | 12 | 2001.32 | 46 | 10.70 | 3425 | 1686 | 1.87 / 533.96 | 1 | 1 |
3 | 7 | 1997.72 | 24 | 11.28 | 3518 | 952 | 2.82 / 534.91 | 1 | 1 |
4 | 13 | 1573.60 | 48 | 12.25 | 2759 | 1622 | 4.44 / 536.53 | 1 | 1 |
5 | 13 | 285.84 | 48 | 13.76 | 784 | 518 | 4.96 / 537.05 | 1 | 1 |
6 | 13 | 28.00 | 48 | 14.25 | 365 | 250 | 5.21 / 537.30 | 1 | 1 |
7 | 8 | -0.04 | 160 | 14.19 | 313 | 711 | 5.92 / 538.01 | 1 | 1 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 26 | 14.38 | 478 | 179 | 0.18 / 526.72 | 1 | 1 |
2 | 12 | 2011.60 | 46 | 10.75 | 3430 | 1696 | 1.87 / 528.41 | 1 | 1 |
3 | 7 | 2009.00 | 24 | 11.37 | 3528 | 963 | 2.84 / 529.38 | 1 | 1 |
4 | 13 | 1449.84 | 48 | 12.37 | 2597 | 1542 | 4.38 / 530.92 | 1 | 1 |
5 | 13 | 290.80 | 48 | 13.74 | 813 | 536 | 4.92 / 531.45 | 1 | 1 |
6 | 8 | 0.08 | 160 | 14.26 | 279 | 637 | 5.55 / 532.09 | 1 | 1 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 26 | 14.36 | 495 | 185 | 0.18 / 520.86 | 1 | 1 |
2 | 12 | 2000.32 | 46 | 10.77 | 3425 | 1697 | 1.88 / 522.56 | 1 | 1 |
3 | 7 | 1996.84 | 24 | 11.39 | 3522 | 963 | 2.84 / 523.52 | 1 | 1 |
4 | 13 | 1551.84 | 48 | 12.27 | 2736 | 1611 | 4.46 / 525.13 | 1 | 1 |
5 | 13 | 265.04 | 48 | 13.78 | 768 | 508 | 4.96 / 525.64 | 1 | 1 |
6 | 13 | 49.28 | 48 | 14.25 | 365 | 250 | 5.21 / 525.89 | 1 | 1 |
7 | 8 | 0.00 | 160 | 14.23 | 285 | 649 | 5.86 / 526.54 | 1 | 1 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 26 | 14.38 | 488 | 182 | 0.18 / 515.15 | 1 | 1 |
2 | 12 | 2001.48 | 46 | 10.63 | 3465 | 1694 | 1.88 / 516.84 | 1 | 1 |
3 | 7 | 1998.52 | 24 | 11.38 | 3508 | 958 | 2.83 / 517.80 | 1 | 1 |
4 | 13 | 1556.20 | 48 | 12.27 | 2769 | 1631 | 4.47 / 519.43 | 1 | 1 |
5 | 13 | 301.48 | 48 | 13.74 | 827 | 545 | 5.01 / 519.98 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.23 | 306 | 697 | 5.71 / 520.68 | 1 | 1 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 26 | 14.39 | 487 | 182 | 0.18 / 509.61 | 1 | 1 |
2 | 12 | 2004.40 | 46 | 10.78 | 3430 | 1701 | 1.88 / 511.31 | 1 | 1 |
3 | 7 | 2001.56 | 24 | 11.41 | 3535 | 968 | 2.85 / 512.28 | 1 | 1 |
4 | 13 | 1323.68 | 48 | 12.52 | 2405 | 1445 | 4.30 / 513.73 | 1 | 1 |
5 | 13 | 332.32 | 48 | 13.71 | 857 | 564 | 4.86 / 514.29 | 1 | 1 |
6 | 8 | 0.16 | 160 | 14.23 | 297 | 676 | 5.54 / 514.97 | 1 | 1 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 26 | 14.37 | 495 | 185 | 0.18 / 504.05 | 1 | 1 |
2 | 12 | 2000.12 | 46 | 10.85 | 3425 | 1709 | 1.89 / 505.76 | 1 | 1 |
3 | 7 | 1996.56 | 24 | 11.42 | 3519 | 964 | 2.86 / 506.73 | 1 | 1 |
4 | 13 | 1409.40 | 48 | 12.46 | 2517 | 1505 | 4.36 / 508.23 | 1 | 1 |
5 | 13 | 281.44 | 48 | 13.77 | 792 | 523 | 4.89 / 508.76 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.22 | 296 | 673 | 5.56 / 509.43 | 1 | 1 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 26 | 14.39 | 483 | 181 | 0.18 / 498.51 | 1 | 1 |
2 | 12 | 2000.36 | 46 | 10.93 | 3422 | 1721 | 1.90 / 500.23 | 1 | 1 |
3 | 7 | 1997.00 | 24 | 11.51 | 3523 | 973 | 2.87 / 501.21 | 1 | 1 |
4 | 13 | 1278.16 | 48 | 12.62 | 2319 | 1405 | 4.28 / 502.61 | 1 | 1 |
5 | 13 | 294.32 | 48 | 13.77 | 810 | 535 | 4.81 / 503.15 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.18 | 319 | 724 | 5.54 / 503.87 | 1 | 1 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 26 | 14.39 | 469 | 175 | 0.18 / 492.64 | 1 | 1 |
2 | 7 | 2004.44 | 48 | 10.85 | 3465 | 1805 | 1.98 / 494.45 | 1 | 1 |
3 | 13 | 1877.56 | 48 | 11.93 | 3287 | 1882 | 3.86 / 496.33 | 1 | 1 |
4 | 13 | 779.60 | 48 | 13.16 | 1562 | 987 | 4.85 / 497.31 | 1 | 1 |
5 | 13 | 112.72 | 48 | 14.11 | 491 | 333 | 5.18 / 497.65 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.21 | 301 | 684 | 5.87 / 498.33 | 1 | 1 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 26 | 14.38 | 474 | 177 | 0.18 / 486.70 | 1 | 1 |
2 | 7 | 2005.52 | 49 | 10.82 | 3508 | 1860 | 2.04 / 488.56 | 1 | 1 |
3 | 13 | 1886.64 | 48 | 11.98 | 3298 | 1896 | 3.93 / 490.45 | 1 | 1 |
4 | 13 | 772.76 | 48 | 13.18 | 1548 | 979 | 4.91 / 491.43 | 1 | 1 |
5 | 13 | 112.32 | 48 | 14.12 | 487 | 330 | 5.24 / 491.76 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.21 | 309 | 703 | 5.95 / 492.47 | 1 | 1 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 26 | 14.42 | 451 | 169 | 0.17 / 480.71 | 1 | 1 |
2 | 7 | 2007.00 | 48 | 10.82 | 3490 | 1813 | 1.98 / 482.53 | 1 | 1 |
3 | 13 | 1896.16 | 48 | 11.93 | 3326 | 1905 | 3.89 / 484.43 | 1 | 1 |
4 | 13 | 931.96 | 48 | 13.01 | 1785 | 1115 | 5.00 / 485.55 | 1 | 1 |
5 | 13 | 106.20 | 48 | 14.15 | 473 | 321 | 5.32 / 485.87 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.25 | 286 | 652 | 5.97 / 486.52 | 1 | 1 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 26 | 14.39 | 485 | 181 | 0.18 / 474.91 | 1 | 1 |
2 | 7 | 2006.84 | 48 | 10.87 | 3488 | 1820 | 2.00 / 476.73 | 1 | 1 |
3 | 13 | 1894.00 | 48 | 11.98 | 3291 | 1892 | 3.89 / 478.62 | 1 | 1 |
4 | 13 | 803.44 | 48 | 13.16 | 1600 | 1011 | 4.90 / 479.63 | 1 | 1 |
5 | 13 | 67.48 | 48 | 14.24 | 403 | 275 | 5.18 / 479.90 | 1 | 1 |
6 | 8 | -0.04 | 160 | 14.23 | 282 | 642 | 5.82 / 480.55 | 1 | 1 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 26 | 14.39 | 484 | 181 | 0.18 / 468.97 | 1 | 1 |
2 | 7 | 2001.68 | 49 | 10.92 | 3490 | 1867 | 2.05 / 470.83 | 1 | 1 |
3 | 13 | 1870.36 | 48 | 12.00 | 3267 | 1882 | 3.93 / 472.72 | 1 | 1 |
4 | 13 | 803.76 | 48 | 13.17 | 1598 | 1010 | 4.94 / 473.73 | 1 | 1 |
5 | 13 | 64.36 | 48 | 14.24 | 408 | 279 | 5.22 / 474.00 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.18 | 317 | 719 | 5.94 / 474.72 | 1 | 1 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 26 | 14.38 | 490 | 183 | 0.18 / 463.33 | 1 | 1 |
2 | 7 | 2001.76 | 49 | 10.81 | 3480 | 1843 | 2.03 / 465.18 | 1 | 1 |
3 | 13 | 1747.32 | 48 | 12.15 | 3077 | 1795 | 3.82 / 466.97 | 1 | 1 |
4 | 13 | 542.36 | 48 | 13.47 | 1197 | 774 | 4.59 / 467.74 | 1 | 1 |
5 | 13 | 87.24 | 48 | 14.15 | 465 | 316 | 4.91 / 468.06 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.16 | 320 | 725 | 5.64 / 468.79 | 1 | 1 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 26 | 14.39 | 485 | 181 | 0.18 / 457.35 | 1 | 1 |
2 | 7 | 2002.84 | 48 | 10.91 | 3491 | 1828 | 2.01 / 459.17 | 1 | 1 |
3 | 13 | 1877.52 | 48 | 12.03 | 3274 | 1891 | 3.90 / 461.06 | 1 | 1 |
4 | 13 | 881.04 | 48 | 13.10 | 1708 | 1074 | 4.97 / 462.14 | 1 | 1 |
5 | 13 | 76.40 | 48 | 14.22 | 421 | 287 | 5.26 / 462.43 | 1 | 1 |
6 | 8 | -0.04 | 160 | 14.17 | 319 | 723 | 5.98 / 463.15 | 1 | 1 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 26 | 14.40 | 461 | 173 | 0.17 / 451.52 | 1 | 1 |
2 | 7 | 2003.04 | 48 | 10.80 | 3494 | 1811 | 1.98 / 453.33 | 1 | 1 |
3 | 13 | 1881.16 | 48 | 12.01 | 3317 | 1912 | 3.90 / 455.24 | 1 | 1 |
4 | 13 | 764.64 | 48 | 13.23 | 1531 | 972 | 4.87 / 456.21 | 1 | 1 |
5 | 13 | 55.16 | 48 | 14.26 | 380 | 260 | 5.13 / 456.47 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.19 | 304 | 690 | 5.82 / 457.16 | 1 | 1 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 26 | 14.40 | 486 | 182 | 0.18 / 445.60 | 1 | 1 |
2 | 7 | 2010.20 | 49 | 10.85 | 3497 | 1859 | 2.04 / 447.46 | 1 | 1 |
3 | 13 | 1895.36 | 48 | 12.02 | 3324 | 1918 | 3.96 / 449.38 | 1 | 1 |
4 | 13 | 761.04 | 48 | 13.25 | 1524 | 969 | 4.93 / 450.34 | 1 | 1 |
5 | 13 | 97.24 | 48 | 14.16 | 459 | 312 | 5.24 / 450.66 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.18 | 304 | 690 | 5.93 / 451.35 | 1 | 1 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 26 | 14.42 | 469 | 176 | 0.18 / 439.84 | 1 | 1 |
2 | 7 | 2015.24 | 49 | 10.76 | 3493 | 1842 | 2.02 / 441.68 | 1 | 1 |
3 | 13 | 1894.80 | 48 | 12.03 | 3321 | 1918 | 3.94 / 443.60 | 1 | 1 |
4 | 13 | 637.32 | 48 | 13.39 | 1340 | 861 | 4.80 / 444.46 | 1 | 1 |
5 | 13 | 58.04 | 48 | 14.27 | 382 | 262 | 5.06 / 444.72 | 1 | 1 |
6 | 8 | 0.08 | 160 | 14.20 | 305 | 693 | 5.75 / 445.42 | 1 | 1 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 26 | 14.41 | 459 | 172 | 0.17 / 434.22 | 1 | 1 |
2 | 7 | 2004.24 | 49 | 10.67 | 3471 | 1815 | 1.99 / 436.03 | 1 | 1 |
3 | 13 | 1888.92 | 48 | 12.06 | 3302 | 1911 | 3.90 / 437.95 | 1 | 1 |
4 | 13 | 512.88 | 48 | 13.55 | 1146 | 745 | 4.64 / 438.69 | 1 | 1 |
5 | 13 | 81.00 | 48 | 14.22 | 423 | 289 | 4.93 / 438.98 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.23 | 301 | 685 | 5.62 / 439.67 | 1 | 1 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 26 | 14.44 | 463 | 174 | 0.17 / 428.18 | 1 | 1 |
2 | 7 | 2002.52 | 48 | 10.70 | 3478 | 1786 | 1.96 / 429.97 | 1 | 1 |
3 | 13 | 1878.68 | 48 | 12.08 | 3290 | 1908 | 3.87 / 431.88 | 1 | 1 |
4 | 13 | 1060.48 | 48 | 13.00 | 1958 | 1222 | 5.09 / 433.10 | 1 | 1 |
5 | 13 | 73.96 | 48 | 14.22 | 416 | 284 | 5.37 / 433.38 | 1 | 1 |
6 | 8 | -0.04 | 160 | 14.21 | 293 | 666 | 6.04 / 434.05 | 1 | 1 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 26 | 14.44 | 463 | 174 | 0.17 / 422.38 | 1 | 1 |
2 | 7 | 2001.80 | 48 | 10.77 | 3486 | 1802 | 1.98 / 424.19 | 1 | 1 |
3 | 13 | 1870.68 | 48 | 12.10 | 3284 | 1907 | 3.88 / 426.09 | 1 | 1 |
4 | 13 | 764.96 | 48 | 13.30 | 1535 | 980 | 4.86 / 427.07 | 1 | 1 |
5 | 13 | 61.20 | 48 | 14.27 | 387 | 265 | 5.13 / 427.34 | 1 | 1 |
6 | 8 | -0.08 | 160 | 14.22 | 294 | 669 | 5.80 / 428.01 | 1 | 1 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 26 | 14.42 | 485 | 182 | 0.18 / 416.66 | 1 | 1 |
2 | 7 | 2004.00 | 49 | 10.67 | 3486 | 1823 | 2.00 / 418.48 | 1 | 1 |
3 | 13 | 1875.44 | 48 | 12.10 | 3268 | 1898 | 3.90 / 420.38 | 1 | 1 |
4 | 13 | 646.40 | 48 | 13.43 | 1350 | 870 | 4.77 / 421.25 | 1 | 1 |
5 | 13 | 69.80 | 48 | 14.26 | 402 | 275 | 5.05 / 421.52 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.21 | 302 | 687 | 5.73 / 422.21 | 1 | 1 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 26 | 14.44 | 462 | 173 | 0.17 / 410.81 | 1 | 1 |
2 | 7 | 2004.52 | 48 | 10.61 | 3485 | 1775 | 1.95 / 412.58 | 1 | 1 |
3 | 13 | 1872.84 | 48 | 12.12 | 3260 | 1897 | 3.84 / 414.48 | 1 | 1 |
4 | 13 | 761.56 | 48 | 13.31 | 1525 | 974 | 4.82 / 415.45 | 1 | 1 |
5 | 13 | 99.24 | 48 | 14.17 | 472 | 321 | 5.14 / 415.77 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.22 | 309 | 703 | 5.84 / 416.48 | 1 | 1 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 26 | 14.47 | 467 | 176 | 0.18 / 405.22 | 1 | 1 |
2 | 7 | 2000.56 | 48 | 10.74 | 3489 | 1799 | 1.97 / 407.02 | 1 | 1 |
3 | 13 | 1729.40 | 48 | 12.31 | 3035 | 1793 | 3.77 / 408.82 | 1 | 1 |
4 | 13 | 627.16 | 48 | 13.47 | 1322 | 855 | 4.62 / 409.67 | 1 | 1 |
5 | 13 | 57.68 | 48 | 14.27 | 385 | 264 | 4.89 / 409.94 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.20 | 307 | 698 | 5.58 / 410.63 | 1 | 1 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 26 | 14.45 | 468 | 176 | 0.18 / 399.47 | 1 | 1 |
2 | 7 | 2004.44 | 48 | 10.76 | 3475 | 1795 | 1.97 / 401.26 | 1 | 1 |
3 | 13 | 1884.08 | 48 | 12.13 | 3305 | 1924 | 3.89 / 403.19 | 1 | 1 |
4 | 13 | 654.36 | 48 | 13.44 | 1362 | 879 | 4.77 / 404.07 | 1 | 1 |
5 | 13 | 56.60 | 48 | 14.25 | 409 | 280 | 5.05 / 404.35 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.19 | 310 | 704 | 5.76 / 405.05 | 1 | 1 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 25 | 14.46 | 452 | 163 | 0.16 / 393.67 | 1 | 1 |
2 | 7 | 2005.56 | 49 | 10.71 | 3469 | 1820 | 1.98 / 395.49 | 1 | 1 |
3 | 13 | 1880.96 | 48 | 12.11 | 3269 | 1900 | 3.88 / 397.39 | 1 | 1 |
4 | 13 | 748.04 | 48 | 13.34 | 1502 | 962 | 4.85 / 398.35 | 1 | 1 |
5 | 13 | 51.16 | 48 | 14.30 | 371 | 255 | 5.10 / 398.61 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.22 | 300 | 683 | 5.78 / 399.29 | 1 | 1 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 26 | 14.52 | 444 | 168 | 0.17 / 389.61 | 1 | 1 |
2 | 7 | 1151.36 | 49 | 11.70 | 2113 | 1211 | 1.38 / 390.82 | 1 | 1 |
3 | 13 | 1073.40 | 48 | 12.84 | 1981 | 1221 | 2.60 / 392.04 | 1 | 1 |
4 | 13 | 289.32 | 48 | 13.85 | 802 | 533 | 3.13 / 392.57 | 1 | 1 |
5 | 13 | 22.64 | 48 | 14.31 | 352 | 242 | 3.37 / 392.81 | 1 | 1 |
6 | 8 | -0.04 | 160 | 14.14 | 307 | 695 | 4.07 / 393.51 | 1 | 1 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 25 | 14.49 | 457 | 166 | 0.17 / 385.75 | 1 | 1 |
2 | 7 | 1205.20 | 48 | 11.75 | 2205 | 1244 | 1.41 / 387.00 | 1 | 1 |
3 | 13 | 1182.16 | 48 | 12.79 | 2134 | 1310 | 2.72 / 388.31 | 1 | 1 |
4 | 13 | 242.40 | 48 | 13.92 | 719 | 480 | 3.20 / 388.79 | 1 | 1 |
5 | 8 | 0.16 | 160 | 14.29 | 286 | 654 | 3.85 / 389.44 | 1 | 1 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 25 | 14.46 | 479 | 173 | 0.17 / 380.00 | 1 | 1 |
2 | 7 | 2001.28 | 48 | 11.00 | 3497 | 1846 | 2.02 / 381.85 | 1 | 1 |
3 | 13 | 1877.28 | 48 | 12.20 | 3268 | 1914 | 3.93 / 383.76 | 1 | 1 |
4 | 13 | 651.80 | 48 | 13.49 | 1359 | 880 | 4.81 / 384.64 | 1 | 1 |
5 | 13 | 62.28 | 48 | 14.29 | 387 | 265 | 5.08 / 384.91 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.23 | 298 | 678 | 5.76 / 385.59 | 1 | 1 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 25 | 14.50 | 472 | 171 | 0.17 / 373.95 | 1 | 1 |
2 | 7 | 2005.80 | 48 | 11.01 | 3522 | 1861 | 2.03 / 375.81 | 1 | 1 |
3 | 13 | 1891.12 | 48 | 12.21 | 3313 | 1942 | 3.97 / 377.75 | 1 | 1 |
4 | 13 | 921.84 | 48 | 13.25 | 1764 | 1122 | 5.10 / 378.88 | 1 | 1 |
5 | 13 | 85.04 | 48 | 14.23 | 437 | 298 | 5.39 / 379.17 | 1 | 1 |
6 | 8 | 0.08 | 160 | 14.26 | 287 | 655 | 6.05 / 379.83 | 1 | 1 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 25 | 14.52 | 460 | 167 | 0.17 / 368.49 | 1 | 1 |
2 | 7 | 2003.12 | 48 | 11.16 | 3515 | 1883 | 2.05 / 370.37 | 1 | 1 |
3 | 13 | 1619.60 | 48 | 12.55 | 2849 | 1716 | 3.77 / 372.09 | 1 | 1 |
4 | 13 | 513.96 | 48 | 13.66 | 1149 | 753 | 4.52 / 372.84 | 1 | 1 |
5 | 13 | 43.28 | 48 | 14.34 | 353 | 243 | 4.76 / 373.09 | 1 | 1 |
6 | 8 | -0.04 | 160 | 14.23 | 305 | 694 | 5.46 / 373.78 | 1 | 1 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 25 | 14.53 | 454 | 165 | 0.16 / 363.17 | 1 | 1 |
2 | 7 | 2004.44 | 48 | 11.14 | 3531 | 1888 | 2.05 / 365.06 | 1 | 1 |
3 | 13 | 1601.32 | 48 | 12.59 | 2825 | 1707 | 3.76 / 366.76 | 1 | 1 |
4 | 13 | 404.28 | 48 | 13.79 | 969 | 641 | 4.40 / 367.40 | 1 | 1 |
5 | 13 | 52.00 | 48 | 14.32 | 368 | 253 | 4.65 / 367.66 | 1 | 1 |
6 | 8 | 0.08 | 160 | 14.25 | 292 | 666 | 5.32 / 368.32 | 1 | 1 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 25 | 14.50 | 458 | 166 | 0.17 / 357.41 | 1 | 1 |
2 | 7 | 2006.52 | 48 | 11.30 | 3533 | 1916 | 2.08 / 359.33 | 1 | 1 |
3 | 13 | 1880.48 | 48 | 12.33 | 3267 | 1934 | 4.02 / 361.26 | 1 | 1 |
4 | 13 | 587.00 | 48 | 13.60 | 1260 | 823 | 4.84 / 362.08 | 1 | 1 |
5 | 13 | 56.76 | 48 | 14.34 | 373 | 257 | 5.10 / 362.34 | 1 | 1 |
6 | 8 | 0.12 | 160 | 14.26 | 291 | 664 | 5.76 / 363.00 | 1 | 1 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 25 | 14.53 | 460 | 167 | 0.17 / 351.51 | 1 | 1 |
2 | 7 | 2009.00 | 48 | 11.40 | 3512 | 1922 | 2.09 / 353.43 | 1 | 1 |
3 | 13 | 1881.08 | 48 | 12.34 | 3265 | 1934 | 4.02 / 355.36 | 1 | 1 |
4 | 13 | 721.12 | 48 | 13.50 | 1458 | 945 | 4.97 / 356.31 | 1 | 1 |
5 | 13 | 73.68 | 48 | 14.30 | 404 | 277 | 5.24 / 356.59 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.26 | 288 | 657 | 5.90 / 357.24 | 1 | 1 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 25 | 14.53 | 464 | 169 | 0.17 / 345.87 | 1 | 1 |
2 | 7 | 2004.20 | 48 | 11.46 | 3524 | 1938 | 2.11 / 347.81 | 1 | 1 |
3 | 13 | 1884.56 | 48 | 12.37 | 3275 | 1945 | 4.05 / 349.76 | 1 | 1 |
4 | 13 | 490.04 | 48 | 13.73 | 1105 | 728 | 4.78 / 350.48 | 1 | 1 |
5 | 13 | 31.96 | 48 | 14.39 | 328 | 227 | 5.01 / 350.71 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.29 | 276 | 631 | 5.64 / 351.34 | 1 | 1 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 25 | 14.58 | 443 | 161 | 0.16 / 340.09 | 1 | 1 |
2 | 7 | 2004.72 | 48 | 11.61 | 3518 | 1961 | 2.12 / 342.05 | 1 | 1 |
3 | 13 | 1876.28 | 48 | 12.43 | 3237 | 1931 | 4.05 / 343.98 | 1 | 1 |
4 | 13 | 575.00 | 48 | 13.65 | 1242 | 814 | 4.87 / 344.79 | 1 | 1 |
5 | 13 | 46.80 | 48 | 14.37 | 351 | 242 | 5.11 / 345.03 | 1 | 1 |
6 | 8 | 0.00 | 160 | 14.28 | 293 | 669 | 5.78 / 345.70 | 1 | 1 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 25 | 14.57 | 458 | 167 | 0.17 / 334.48 | 1 | 1 |
2 | 7 | 2001.92 | 48 | 11.73 | 3509 | 1976 | 2.14 / 336.46 | 1 | 1 |
3 | 13 | 1747.68 | 48 | 12.62 | 3071 | 1860 | 4.00 / 338.32 | 1 | 1 |
4 | 13 | 503.56 | 48 | 13.75 | 1126 | 743 | 4.75 / 339.06 | 1 | 1 |
5 | 13 | 34.88 | 48 | 14.40 | 333 | 230 | 4.98 / 339.29 | 1 | 1 |
6 | 8 | 0.08 | 160 | 14.30 | 278 | 636 | 5.61 / 339.93 | 1 | 1 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 25 | 14.57 | 443 | 161 | 0.16 / 328.85 | 1 | 1 |
2 | 7 | 2005.64 | 48 | 11.82 | 3516 | 1995 | 2.16 / 330.85 | 1 | 1 |
3 | 13 | 1743.52 | 48 | 12.69 | 3036 | 1849 | 4.01 / 332.70 | 1 | 1 |
4 | 13 | 455.36 | 48 | 13.80 | 1050 | 696 | 4.70 / 333.39 | 1 | 1 |
5 | 13 | 47.72 | 48 | 14.37 | 361 | 249 | 4.95 / 333.64 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.29 | 294 | 672 | 5.62 / 334.31 | 1 | 1 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 25 | 14.60 | 446 | 163 | 0.16 / 323.04 | 1 | 1 |
2 | 7 | 2002.92 | 48 | 11.98 | 3510 | 2018 | 2.18 / 325.06 | 1 | 1 |
3 | 13 | 1873.40 | 48 | 12.55 | 3237 | 1950 | 4.13 / 327.01 | 1 | 1 |
4 | 13 | 567.48 | 48 | 13.70 | 1232 | 810 | 4.94 / 327.82 | 1 | 1 |
5 | 13 | 21.24 | 48 | 14.43 | 307 | 213 | 5.15 / 328.03 | 1 | 1 |
6 | 8 | -0.08 | 160 | 14.30 | 289 | 661 | 5.82 / 328.69 | 1 | 1 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 25 | 14.59 | 440 | 160 | 0.16 / 317.58 | 1 | 1 |
2 | 7 | 2002.64 | 48 | 12.03 | 3487 | 2014 | 2.17 / 319.59 | 1 | 1 |
3 | 13 | 1735.72 | 48 | 12.74 | 3023 | 1849 | 4.02 / 321.44 | 1 | 1 |
4 | 13 | 328.84 | 48 | 13.98 | 845 | 567 | 4.59 / 322.01 | 1 | 1 |
5 | 13 | 31.60 | 48 | 14.42 | 326 | 226 | 4.82 / 322.23 | 1 | 1 |
6 | 8 | -0.08 | 160 | 14.32 | 280 | 642 | 5.46 / 322.88 | 1 | 1 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 25 | 14.60 | 468 | 171 | 0.17 / 311.84 | 1 | 1 |
2 | 7 | 2016.04 | 48 | 12.12 | 3519 | 2047 | 2.22 / 313.89 | 1 | 1 |
3 | 13 | 1885.96 | 48 | 12.60 | 3259 | 1971 | 4.19 / 315.86 | 1 | 1 |
4 | 13 | 444.48 | 48 | 13.86 | 1025 | 682 | 4.87 / 316.54 | 1 | 1 |
5 | 13 | 23.24 | 48 | 14.45 | 309 | 214 | 5.09 / 316.75 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.32 | 290 | 664 | 5.75 / 317.42 | 1 | 1 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 25 | 14.62 | 449 | 164 | 0.16 / 306.06 | 1 | 1 |
2 | 7 | 2008.28 | 48 | 12.26 | 3510 | 2066 | 2.23 / 308.13 | 1 | 1 |
3 | 13 | 1734.32 | 48 | 12.82 | 3016 | 1856 | 4.09 / 309.98 | 1 | 1 |
4 | 13 | 577.80 | 48 | 13.74 | 1240 | 818 | 4.90 / 310.80 | 1 | 1 |
5 | 13 | 20.52 | 48 | 14.47 | 297 | 206 | 5.11 / 311.01 | 1 | 1 |
6 | 8 | -0.04 | 160 | 14.30 | 289 | 661 | 5.77 / 311.67 | 1 | 1 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 25 | 14.62 | 453 | 166 | 0.17 / 300.42 | 1 | 1 |
2 | 7 | 2007.72 | 48 | 12.34 | 3514 | 2081 | 2.25 / 302.50 | 1 | 1 |
3 | 13 | 1743.80 | 48 | 12.84 | 3027 | 1866 | 4.11 / 304.36 | 1 | 1 |
4 | 13 | 455.40 | 48 | 13.86 | 1044 | 695 | 4.81 / 305.06 | 1 | 1 |
5 | 13 | 24.72 | 48 | 14.47 | 307 | 213 | 5.02 / 305.27 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.37 | 273 | 628 | 5.65 / 305.90 | 1 | 1 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 25 | 14.61 | 480 | 175 | 0.18 / 295.04 | 1 | 1 |
2 | 7 | 2005.48 | 49 | 12.48 | 3453 | 2112 | 2.29 / 297.15 | 1 | 1 |
3 | 13 | 1689.28 | 48 | 12.93 | 2939 | 1824 | 4.11 / 298.98 | 1 | 1 |
4 | 13 | 385.00 | 48 | 13.94 | 932 | 624 | 4.73 / 299.60 | 1 | 1 |
5 | 8 | 0.08 | 160 | 14.41 | 282 | 650 | 5.38 / 300.25 | 1 | 1 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 25 | 14.63 | 430 | 157 | 0.16 / 289.54 | 1 | 1 |
2 | 7 | 2004.24 | 48 | 12.55 | 3451 | 2079 | 2.24 / 291.62 | 1 | 1 |
3 | 13 | 1883.84 | 48 | 12.76 | 3241 | 1985 | 4.22 / 293.61 | 1 | 1 |
4 | 13 | 411.60 | 48 | 13.93 | 969 | 648 | 4.87 / 294.25 | 1 | 1 |
5 | 8 | 0.08 | 160 | 14.43 | 265 | 612 | 5.48 / 294.87 | 1 | 1 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 25 | 14.64 | 447 | 164 | 0.16 / 284.37 | 1 | 1 |
2 | 7 | 2003.44 | 48 | 12.64 | 3456 | 2097 | 2.26 / 286.47 | 1 | 1 |
3 | 13 | 1591.96 | 48 | 13.02 | 2801 | 1751 | 4.01 / 288.22 | 1 | 1 |
4 | 13 | 307.16 | 48 | 14.05 | 822 | 554 | 4.57 / 288.77 | 1 | 1 |
5 | 8 | 0.16 | 160 | 14.44 | 264 | 610 | 5.18 / 289.38 | 1 | 1 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 25 | 14.64 | 476 | 174 | 0.17 / 279.12 | 1 | 1 |
2 | 7 | 2001.72 | 49 | 12.70 | 3445 | 2144 | 2.32 / 281.26 | 1 | 1 |
3 | 13 | 1588.88 | 48 | 13.04 | 2789 | 1746 | 4.06 / 283.01 | 1 | 1 |
4 | 13 | 313.16 | 48 | 14.05 | 826 | 557 | 4.62 / 283.57 | 1 | 1 |
5 | 8 | 0.04 | 160 | 14.41 | 279 | 643 | 5.26 / 284.21 | 1 | 1 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 25 | 14.64 | 457 | 167 | 0.17 / 273.77 | 1 | 1 |
2 | 7 | 2003.24 | 49 | 12.72 | 3471 | 2163 | 2.33 / 275.94 | 1 | 1 |
3 | 13 | 1563.16 | 48 | 13.08 | 2757 | 1731 | 4.06 / 277.67 | 1 | 1 |
4 | 13 | 420.88 | 48 | 13.94 | 988 | 661 | 4.72 / 278.33 | 1 | 1 |
5 | 8 | 0.12 | 160 | 14.44 | 266 | 615 | 5.34 / 278.94 | 1 | 1 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 25 | 14.67 | 437 | 160 | 0.16 / 268.44 | 1 | 1 |
2 | 7 | 2003.32 | 48 | 12.76 | 3469 | 2125 | 2.28 / 270.57 | 1 | 1 |
3 | 13 | 1725.84 | 48 | 12.99 | 2999 | 1870 | 4.15 / 272.44 | 1 | 1 |
4 | 13 | 282.96 | 48 | 14.09 | 780 | 528 | 4.68 / 272.96 | 1 | 1 |
5 | 8 | 0.08 | 160 | 14.44 | 279 | 645 | 5.33 / 273.61 | 1 | 1 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 25 | 14.65 | 448 | 164 | 0.16 / 263.13 | 1 | 1 |
2 | 7 | 2004.16 | 48 | 12.81 | 3448 | 2120 | 2.28 / 265.25 | 1 | 1 |
3 | 13 | 1464.72 | 48 | 13.19 | 2577 | 1632 | 3.92 / 266.89 | 1 | 1 |
4 | 13 | 316.40 | 48 | 14.07 | 831 | 561 | 4.48 / 267.45 | 1 | 1 |
5 | 13 | 23.84 | 48 | 14.52 | 302 | 210 | 4.69 / 267.66 | 1 | 1 |
6 | 8 | -0.08 | 160 | 14.41 | 270 | 623 | 5.31 / 268.28 | 1 | 1 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 25 | 14.65 | 469 | 172 | 0.17 / 257.71 | 1 | 1 |
2 | 7 | 2002.60 | 48 | 12.83 | 3445 | 2122 | 2.29 / 259.83 | 1 | 1 |
3 | 13 | 1723.88 | 48 | 13.02 | 2989 | 1868 | 4.16 / 261.70 | 1 | 1 |
4 | 13 | 409.08 | 48 | 13.98 | 967 | 649 | 4.81 / 262.34 | 1 | 1 |
5 | 8 | -0.04 | 160 | 14.45 | 271 | 627 | 5.44 / 262.97 | 1 | 1 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 25 | 14.68 | 444 | 163 | 0.16 / 252.53 | 1 | 1 |
2 | 7 | 2002.68 | 48 | 12.86 | 3446 | 2127 | 2.29 / 254.66 | 1 | 1 |
3 | 13 | 1476.36 | 48 | 13.20 | 2602 | 1649 | 3.94 / 256.31 | 1 | 1 |
4 | 13 | 342.12 | 48 | 14.05 | 872 | 588 | 4.53 / 256.89 | 1 | 1 |
5 | 8 | 0.04 | 160 | 14.45 | 277 | 640 | 5.17 / 257.53 | 1 | 1 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 25 | 14.68 | 448 | 164 | 0.16 / 247.24 | 1 | 1 |
2 | 7 | 2002.40 | 49 | 12.88 | 3435 | 2168 | 2.33 / 249.41 | 1 | 1 |
3 | 13 | 1595.00 | 48 | 13.15 | 2777 | 1753 | 4.09 / 251.16 | 1 | 1 |
4 | 13 | 303.64 | 48 | 14.10 | 815 | 552 | 4.64 / 251.71 | 1 | 1 |
5 | 8 | 0.04 | 160 | 14.46 | 282 | 652 | 5.29 / 252.37 | 1 | 1 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 25 | 14.69 | 455 | 167 | 0.17 / 241.47 | 1 | 1 |
2 | 7 | 2012.40 | 49 | 12.85 | 3491 | 2198 | 2.37 / 243.66 | 1 | 1 |
3 | 13 | 1885.48 | 48 | 12.89 | 3257 | 2015 | 4.38 / 245.68 | 1 | 1 |
4 | 13 | 518.84 | 48 | 13.90 | 1144 | 763 | 5.14 / 246.44 | 1 | 1 |
5 | 8 | 0.20 | 160 | 14.47 | 274 | 634 | 5.78 / 247.08 | 1 | 1 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 25 | 14.71 | 433 | 159 | 0.16 / 236.15 | 1 | 1 |
2 | 7 | 2006.20 | 49 | 12.88 | 3457 | 2182 | 2.34 / 238.34 | 1 | 1 |
3 | 13 | 1600.76 | 48 | 13.15 | 2805 | 1771 | 4.11 / 240.11 | 1 | 1 |
4 | 13 | 306.76 | 48 | 14.11 | 817 | 553 | 4.66 / 240.66 | 1 | 1 |
5 | 8 | 0.08 | 160 | 14.48 | 276 | 639 | 5.30 / 241.30 | 1 | 1 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 25 | 14.71 | 436 | 160 | 0.16 / 230.95 | 1 | 1 |
2 | 7 | 2005.80 | 48 | 12.88 | 3461 | 2140 | 2.30 / 233.09 | 1 | 1 |
3 | 13 | 1586.36 | 48 | 13.16 | 2787 | 1760 | 4.06 / 234.85 | 1 | 1 |
4 | 13 | 291.12 | 48 | 14.13 | 793 | 538 | 4.60 / 235.38 | 1 | 1 |
5 | 8 | -0.04 | 160 | 14.47 | 264 | 611 | 5.21 / 236.00 | 1 | 1 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 25 | 14.71 | 462 | 170 | 0.17 / 225.77 | 1 | 1 |
2 | 7 | 2007.20 | 49 | 12.89 | 3453 | 2181 | 2.35 / 227.95 | 1 | 1 |
3 | 13 | 1459.80 | 48 | 13.26 | 2599 | 1654 | 4.01 / 229.60 | 1 | 1 |
4 | 13 | 333.72 | 48 | 14.10 | 858 | 581 | 4.59 / 230.18 | 1 | 1 |
5 | 8 | -0.04 | 160 | 14.50 | 260 | 603 | 5.19 / 230.79 | 1 | 1 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 25 | 14.73 | 425 | 157 | 0.16 / 220.28 | 1 | 1 |
2 | 7 | 2002.60 | 49 | 12.90 | 3424 | 2164 | 2.32 / 222.44 | 1 | 1 |
3 | 13 | 1722.20 | 48 | 13.09 | 3007 | 1889 | 4.21 / 224.33 | 1 | 1 |
4 | 13 | 386.76 | 48 | 14.06 | 927 | 626 | 4.84 / 224.96 | 1 | 1 |
5 | 8 | 0.16 | 160 | 14.51 | 276 | 641 | 5.48 / 225.60 | 1 | 1 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 25 | 14.76 | 441 | 163 | 0.16 / 214.55 | 1 | 1 |
2 | 7 | 2005.08 | 49 | 12.91 | 3452 | 2184 | 2.35 / 216.73 | 1 | 1 |
3 | 13 | 1732.48 | 48 | 13.10 | 2996 | 1884 | 4.23 / 218.61 | 1 | 1 |
4 | 13 | 430.04 | 48 | 14.02 | 998 | 672 | 4.90 / 219.28 | 1 | 1 |
5 | 13 | 22.56 | 48 | 14.60 | 294 | 206 | 5.11 / 219.49 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.46 | 272 | 629 | 5.74 / 220.12 | 1 | 1 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 25 | 14.71 | 456 | 168 | 0.17 / 209.34 | 1 | 1 |
2 | 7 | 2002.04 | 48 | 12.92 | 3410 | 2115 | 2.28 / 211.45 | 1 | 1 |
3 | 13 | 1601.32 | 48 | 13.18 | 2810 | 1778 | 4.06 / 213.23 | 1 | 1 |
4 | 13 | 296.80 | 48 | 14.14 | 803 | 545 | 4.61 / 213.77 | 1 | 1 |
5 | 8 | 0.04 | 160 | 14.52 | 262 | 609 | 5.21 / 214.38 | 1 | 1 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 25 | 14.73 | 445 | 164 | 0.16 / 204.12 | 1 | 1 |
2 | 7 | 2000.76 | 49 | 12.91 | 3462 | 2190 | 2.35 / 206.31 | 1 | 1 |
3 | 13 | 1567.44 | 48 | 13.22 | 2722 | 1727 | 4.08 / 208.04 | 1 | 1 |
4 | 13 | 267.36 | 48 | 14.19 | 750 | 511 | 4.59 / 208.55 | 1 | 1 |
5 | 8 | 0.00 | 160 | 14.49 | 268 | 621 | 5.21 / 209.17 | 1 | 1 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 25 | 14.72 | 451 | 166 | 0.17 / 198.89 | 1 | 1 |
2 | 7 | 2001.72 | 48 | 12.90 | 3438 | 2129 | 2.29 / 201.02 | 1 | 1 |
3 | 13 | 1575.96 | 48 | 13.20 | 2755 | 1746 | 4.04 / 202.77 | 1 | 1 |
4 | 13 | 277.16 | 48 | 14.16 | 796 | 541 | 4.58 / 203.31 | 1 | 1 |
5 | 8 | 0.12 | 160 | 14.50 | 279 | 647 | 5.23 / 203.96 | 1 | 1 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 25 | 14.74 | 451 | 166 | 0.17 / 193.58 | 1 | 1 |
2 | 7 | 2006.40 | 49 | 12.90 | 3472 | 2195 | 2.36 / 195.78 | 1 | 1 |
3 | 13 | 1603.92 | 48 | 13.20 | 2795 | 1771 | 4.13 / 197.55 | 1 | 1 |
4 | 13 | 321.52 | 48 | 14.13 | 827 | 561 | 4.69 / 198.11 | 1 | 1 |
5 | 8 | 0.04 | 160 | 14.50 | 266 | 617 | 5.31 / 198.73 | 1 | 1 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 25 | 14.72 | 445 | 164 | 0.16 / 188.01 | 1 | 1 |
2 | 7 | 2007.88 | 49 | 12.90 | 3464 | 2190 | 2.35 / 190.20 | 1 | 1 |
3 | 13 | 1881.12 | 48 | 12.96 | 3224 | 2006 | 4.36 / 192.20 | 1 | 1 |
4 | 13 | 351.80 | 48 | 14.10 | 880 | 596 | 4.95 / 192.80 | 1 | 1 |
5 | 8 | 0.08 | 160 | 14.53 | 267 | 621 | 5.58 / 193.42 | 1 | 1 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 24 | 14.73 | 458 | 162 | 0.16 / 182.66 | 1 | 1 |
2 | 7 | 2002.88 | 45 | 12.94 | 3477 | 2025 | 2.19 / 184.68 | 1 | 1 |
3 | 13 | 1587.88 | 48 | 13.18 | 2773 | 1754 | 3.94 / 186.44 | 1 | 1 |
4 | 13 | 307.72 | 48 | 14.14 | 807 | 548 | 4.49 / 186.99 | 1 | 1 |
5 | 13 | 66.20 | 48 | 14.51 | 375 | 261 | 4.75 / 187.25 | 1 | 1 |
6 | 8 | 0.00 | 150 | 14.46 | 274 | 594 | 5.34 / 187.84 | 1 | 1 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 25 | 14.74 | 433 | 160 | 0.16 / 177.05 | 1 | 1 |
2 | 7 | 2001.88 | 44 | 12.95 | 3448 | 1965 | 2.12 / 179.02 | 1 | 1 |
3 | 13 | 1873.56 | 48 | 12.96 | 3201 | 1991 | 4.12 / 181.01 | 1 | 1 |
4 | 13 | 399.44 | 48 | 14.06 | 951 | 642 | 4.76 / 181.65 | 1 | 1 |
5 | 13 | 52.32 | 48 | 14.57 | 349 | 244 | 5.00 / 181.90 | 1 | 1 |
6 | 8 | 0.04 | 150 | 14.48 | 277 | 602 | 5.60 / 182.50 | 1 | 1 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 25 | 14.74 | 451 | 166 | 0.17 / 172.02 | 1 | 1 |
2 | 7 | 2004.04 | 44 | 12.93 | 3473 | 1976 | 2.14 / 173.99 | 1 | 1 |
3 | 13 | 1592.44 | 48 | 13.17 | 2802 | 1771 | 3.91 / 175.76 | 1 | 1 |
4 | 13 | 321.32 | 48 | 14.13 | 838 | 568 | 4.48 / 176.33 | 1 | 1 |
5 | 8 | 0.04 | 150 | 14.53 | 258 | 562 | 5.04 / 176.89 | 1 | 1 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 25 | 14.73 | 458 | 169 | 0.17 / 166.40 | 1 | 1 |
2 | 7 | 2004.32 | 44 | 12.93 | 3458 | 1967 | 2.14 / 168.37 | 1 | 1 |
3 | 13 | 1872.28 | 48 | 12.94 | 3208 | 1993 | 4.13 / 170.36 | 1 | 1 |
4 | 13 | 401.08 | 48 | 14.07 | 956 | 646 | 4.77 / 171.01 | 1 | 1 |
5 | 13 | 47.92 | 48 | 14.56 | 352 | 246 | 5.02 / 171.25 | 1 | 1 |
6 | 8 | -0.08 | 150 | 14.48 | 276 | 599 | 5.62 / 171.85 | 1 | 1 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 25 | 14.78 | 425 | 157 | 0.16 / 161.30 | 1 | 1 |
2 | 7 | 2004.08 | 44 | 12.93 | 3445 | 1960 | 2.12 / 163.26 | 1 | 1 |
3 | 13 | 1594.48 | 48 | 13.16 | 2789 | 1762 | 3.88 / 165.03 | 1 | 1 |
4 | 13 | 334.04 | 48 | 14.14 | 843 | 572 | 4.45 / 165.60 | 1 | 1 |
5 | 8 | 0.12 | 150 | 14.52 | 291 | 634 | 5.08 / 166.23 | 1 | 1 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 25 | 14.76 | 445 | 164 | 0.16 / 156.27 | 1 | 1 |
2 | 7 | 2004.00 | 44 | 12.96 | 3462 | 1974 | 2.14 / 158.24 | 1 | 1 |
3 | 13 | 1750.72 | 32 | 13.23 | 3030 | 1283 | 3.42 / 159.52 | 1 | 1 |
4 | 13 | 844.40 | 32 | 13.82 | 1644 | 727 | 4.15 / 160.25 | 1 | 1 |
5 | 13 | 124.92 | 32 | 14.52 | 479 | 223 | 4.37 / 160.47 | 1 | 1 |
6 | 13 | 15.84 | 32 | 14.69 | 273 | 128 | 4.50 / 160.60 | 1 | 1 |
7 | 8 | 0.08 | 150 | 14.51 | 251 | 546 | 5.05 / 161.15 | 1 | 1 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 25 | 14.78 | 419 | 155 | 0.15 / 151.44 | 1 | 1 |
2 | 7 | 2002.32 | 45 | 12.95 | 3461 | 2017 | 2.17 / 153.45 | 1 | 1 |
3 | 13 | 1594.04 | 32 | 13.32 | 2816 | 1200 | 3.37 / 154.65 | 1 | 1 |
4 | 13 | 710.40 | 32 | 13.92 | 1448 | 645 | 4.02 / 155.30 | 1 | 1 |
5 | 13 | 126.92 | 32 | 14.52 | 482 | 224 | 4.24 / 155.52 | 1 | 1 |
6 | 8 | 0.12 | 150 | 14.55 | 265 | 578 | 4.82 / 156.10 | 1 | 1 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 24 | 14.77 | 433 | 153 | 0.15 / 146.61 | 1 | 1 |
2 | 7 | 2003.48 | 44 | 12.96 | 3454 | 1970 | 2.12 / 148.58 | 1 | 1 |
3 | 13 | 1597.12 | 32 | 13.33 | 2803 | 1196 | 3.32 / 149.78 | 1 | 1 |
4 | 13 | 849.52 | 32 | 13.82 | 1661 | 735 | 4.05 / 150.51 | 1 | 1 |
5 | 13 | 124.52 | 32 | 14.53 | 477 | 222 | 4.28 / 150.73 | 1 | 1 |
6 | 8 | 0.08 | 150 | 14.58 | 250 | 547 | 4.82 / 151.28 | 1 | 1 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 24 | 14.80 | 426 | 151 | 0.15 / 141.78 | 1 | 1 |
2 | 7 | 2002.88 | 44 | 12.97 | 3474 | 1983 | 2.13 / 143.76 | 1 | 1 |
3 | 13 | 1735.60 | 32 | 13.25 | 3019 | 1280 | 3.41 / 145.04 | 1 | 1 |
4 | 13 | 698.48 | 32 | 13.94 | 1430 | 638 | 4.05 / 145.68 | 1 | 1 |
5 | 13 | 134.64 | 32 | 14.52 | 499 | 232 | 4.28 / 145.91 | 1 | 1 |
6 | 8 | 0.12 | 150 | 14.59 | 250 | 547 | 4.83 / 146.46 | 1 | 1 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 24 | 14.82 | 429 | 153 | 0.15 / 136.77 | 1 | 1 |
2 | 7 | 2009.40 | 44 | 12.97 | 3473 | 1982 | 2.13 / 138.75 | 1 | 1 |
3 | 13 | 1885.16 | 32 | 13.13 | 3266 | 1372 | 3.51 / 140.12 | 1 | 1 |
4 | 13 | 834.68 | 32 | 13.85 | 1631 | 723 | 4.23 / 140.85 | 1 | 1 |
5 | 13 | 120.36 | 32 | 14.54 | 476 | 221 | 4.45 / 141.07 | 1 | 1 |
6 | 8 | 0.12 | 150 | 14.58 | 257 | 562 | 5.01 / 141.63 | 1 | 1 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 24 | 14.78 | 417 | 148 | 0.15 / 131.65 | 1 | 1 |
2 | 7 | 2006.04 | 44 | 12.99 | 3474 | 1986 | 2.13 / 133.64 | 1 | 1 |
3 | 13 | 1875.60 | 32 | 13.15 | 3264 | 1373 | 3.51 / 135.01 | 1 | 1 |
4 | 13 | 950.08 | 32 | 13.78 | 1799 | 793 | 4.30 / 135.80 | 1 | 1 |
5 | 13 | 146.64 | 32 | 14.49 | 528 | 245 | 4.55 / 136.05 | 1 | 1 |
6 | 8 | -0.04 | 150 | 14.57 | 260 | 568 | 5.11 / 136.62 | 1 | 1 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 24 | 14.78 | 448 | 159 | 0.16 / 126.56 | 1 | 1 |
2 | 7 | 2002.84 | 44 | 13.02 | 3449 | 1976 | 2.13 / 128.54 | 1 | 1 |
3 | 13 | 1597.72 | 41 | 13.28 | 2788 | 1518 | 3.65 / 130.06 | 1 | 1 |
4 | 13 | 499.20 | 41 | 14.04 | 1114 | 641 | 4.29 / 130.70 | 1 | 1 |
5 | 13 | 81.36 | 41 | 14.58 | 396 | 237 | 4.53 / 130.93 | 1 | 1 |
6 | 8 | 0.08 | 150 | 14.57 | 260 | 568 | 5.10 / 131.50 | 1 | 1 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 24 | 14.79 | 450 | 160 | 0.16 / 121.32 | 1 | 1 |
2 | 7 | 1971.00 | 44 | 13.05 | 3427 | 1968 | 2.13 / 123.28 | 1 | 1 |
3 | 13 | 1707.40 | 41 | 13.24 | 2955 | 1604 | 3.73 / 124.89 | 1 | 1 |
4 | 13 | 589.64 | 41 | 13.98 | 1253 | 718 | 4.45 / 125.61 | 1 | 1 |
5 | 13 | 65.64 | 41 | 14.62 | 367 | 220 | 4.67 / 125.83 | 1 | 1 |
6 | 8 | -0.08 | 150 | 14.58 | 264 | 577 | 5.25 / 126.40 | 1 | 1 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 24 | 14.79 | 460 | 163 | 0.16 / 116.24 | 1 | 1 |
2 | 7 | 2001.92 | 44 | 13.07 | 3473 | 1997 | 2.16 / 118.23 | 1 | 1 |
3 | 13 | 1585.48 | 41 | 13.32 | 2754 | 1504 | 3.66 / 119.74 | 1 | 1 |
4 | 13 | 484.52 | 41 | 14.08 | 1082 | 625 | 4.29 / 120.36 | 1 | 1 |
5 | 13 | 78.92 | 41 | 14.61 | 388 | 232 | 4.52 / 120.59 | 1 | 1 |
6 | 8 | 0.08 | 150 | 14.60 | 257 | 563 | 5.08 / 121.16 | 1 | 1 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 25 | 14.82 | 417 | 154 | 0.15 / 110.80 | 1 | 1 |
2 | 7 | 2005.44 | 44 | 13.09 | 3440 | 1981 | 2.14 / 112.78 | 1 | 1 |
3 | 13 | 1874.72 | 41 | 13.11 | 3235 | 1739 | 3.87 / 114.52 | 1 | 1 |
4 | 13 | 582.12 | 41 | 14.00 | 1241 | 712 | 4.59 / 115.23 | 1 | 1 |
5 | 13 | 109.68 | 41 | 14.55 | 451 | 269 | 4.86 / 115.50 | 1 | 1 |
6 | 8 | 0.00 | 150 | 14.58 | 262 | 573 | 5.43 / 116.07 | 1 | 1 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 24 | 14.81 | 442 | 157 | 0.16 / 105.56 | 1 | 1 |
2 | 7 | 2005.00 | 44 | 13.10 | 3461 | 1995 | 2.15 / 107.56 | 1 | 1 |
3 | 13 | 1872.76 | 41 | 13.16 | 3215 | 1735 | 3.89 / 109.29 | 1 | 1 |
4 | 13 | 436.48 | 41 | 14.14 | 1004 | 582 | 4.47 / 109.87 | 1 | 1 |
5 | 13 | 62.04 | 41 | 14.67 | 358 | 215 | 4.68 / 110.09 | 1 | 1 |
6 | 8 | 0.00 | 150 | 14.59 | 253 | 554 | 5.24 / 110.64 | 1 | 1 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 24 | 14.84 | 426 | 152 | 0.15 / 100.26 | 1 | 1 |
2 | 7 | 2011.20 | 44 | 13.10 | 3477 | 2004 | 2.16 / 102.27 | 1 | 1 |
3 | 13 | 1881.92 | 41 | 13.14 | 3257 | 1755 | 3.91 / 104.02 | 1 | 1 |
4 | 13 | 455.64 | 41 | 14.12 | 1035 | 599 | 4.51 / 104.62 | 1 | 1 |
5 | 13 | 73.76 | 41 | 14.66 | 372 | 224 | 4.73 / 104.84 | 1 | 1 |
6 | 8 | -0.08 | 150 | 14.60 | 256 | 561 | 5.29 / 105.41 | 1 | 1 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 24 | 14.86 | 427 | 152 | 0.15 / 96.16 | 1 | 1 |
2 | 7 | 1531.16 | 45 | 13.38 | 2677 | 1612 | 1.76 / 97.77 | 1 | 1 |
3 | 13 | 1415.88 | 31 | 13.50 | 2502 | 1047 | 2.81 / 98.82 | 1 | 1 |
4 | 13 | 562.40 | 31 | 14.10 | 1216 | 532 | 3.34 / 99.35 | 1 | 1 |
5 | 13 | 122.84 | 31 | 14.56 | 480 | 217 | 3.56 / 99.56 | 1 | 1 |
6 | 8 | 0.04 | 150 | 14.63 | 249 | 546 | 4.11 / 100.11 | 1 | 1 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 24 | 14.87 | 406 | 145 | 0.14 / 91.46 | 1 | 1 |
2 | 3 | 1028.00 | 1 | 14.56 | 2037 | 30 | 0.17 / 91.49 | 1 | 1 |
3 | 7 | 2002.36 | 45 | 13.17 | 3455 | 2048 | 2.22 / 93.54 | 1 | 1 |
4 | 13 | 1579.36 | 30 | 13.47 | 2753 | 1112 | 3.33 / 94.65 | 1 | 1 |
5 | 13 | 692.12 | 30 | 14.01 | 1414 | 594 | 3.93 / 95.24 | 1 | 1 |
6 | 13 | 132.40 | 30 | 14.58 | 494 | 216 | 4.15 / 95.46 | 1 | 1 |
7 | 8 | 0.08 | 150 | 14.66 | 248 | 545 | 4.69 / 96.01 | 1 | 1 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 24 | 14.85 | 410 | 146 | 0.15 / 86.54 | 1 | 1 |
2 | 7 | 2001.68 | 42 | 13.21 | 3464 | 1922 | 2.07 / 88.47 | 1 | 1 |
3 | 13 | 1619.60 | 30 | 13.45 | 2811 | 1134 | 3.20 / 89.60 | 1 | 1 |
4 | 13 | 1008.08 | 30 | 13.82 | 1878 | 779 | 3.98 / 90.38 | 1 | 1 |
5 | 13 | 145.32 | 30 | 14.59 | 514 | 225 | 4.21 / 90.60 | 1 | 1 |
6 | 13 | 74.68 | 30 | 14.70 | 377 | 166 | 4.37 / 90.77 | 1 | 1 |
7 | 8 | 0.08 | 150 | 14.64 | 248 | 545 | 4.92 / 91.32 | 1 | 1 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 24 | 14.91 | 416 | 149 | 0.15 / 81.66 | 1 | 1 |
2 | 7 | 2003.32 | 43 | 13.22 | 3423 | 1946 | 2.09 / 83.61 | 1 | 1 |
3 | 13 | 1595.00 | 30 | 13.45 | 2806 | 1132 | 3.23 / 84.74 | 1 | 1 |
4 | 13 | 836.96 | 30 | 13.92 | 1632 | 682 | 3.91 / 85.42 | 1 | 1 |
5 | 13 | 207.00 | 30 | 14.46 | 640 | 278 | 4.19 / 85.70 | 1 | 1 |
6 | 13 | 42.48 | 30 | 14.74 | 327 | 145 | 4.33 / 85.84 | 1 | 1 |
7 | 8 | 0.16 | 150 | 14.60 | 253 | 554 | 4.88 / 86.40 | 1 | 1 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 24 | 14.89 | 423 | 151 | 0.15 / 76.58 | 1 | 1 |
2 | 7 | 2002.68 | 42 | 13.24 | 3437 | 1911 | 2.06 / 78.49 | 1 | 1 |
3 | 13 | 1737.32 | 31 | 13.40 | 3016 | 1253 | 3.32 / 79.74 | 1 | 1 |
4 | 13 | 985.88 | 31 | 13.83 | 1846 | 791 | 4.11 / 80.53 | 1 | 1 |
5 | 13 | 207.36 | 31 | 14.47 | 643 | 288 | 4.40 / 80.82 | 1 | 1 |
6 | 8 | 0.00 | 190 | 14.62 | 250 | 694 | 5.09 / 81.51 | 1 | 1 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 24 | 14.96 | 412 | 148 | 0.15 / 71.82 | 1 | 1 |
2 | 7 | 2002.08 | 42 | 13.23 | 3435 | 1909 | 2.06 / 73.73 | 1 | 1 |
3 | 13 | 1584.16 | 31 | 13.48 | 2763 | 1155 | 3.21 / 74.89 | 1 | 1 |
4 | 13 | 699.28 | 31 | 14.02 | 1423 | 618 | 3.83 / 75.51 | 1 | 1 |
5 | 13 | 128.20 | 31 | 14.61 | 489 | 221 | 4.05 / 75.73 | 1 | 1 |
6 | 8 | 0.00 | 190 | 14.61 | 251 | 697 | 4.75 / 76.42 | 1 | 1 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 24 | 14.94 | 413 | 148 | 0.15 / 67.20 | 1 | 1 |
2 | 7 | 2002.40 | 42 | 13.24 | 3464 | 1926 | 2.07 / 69.13 | 1 | 1 |
3 | 13 | 1464.08 | 29 | 13.56 | 2589 | 1018 | 3.09 / 70.15 | 1 | 1 |
4 | 13 | 804.68 | 29 | 13.97 | 1577 | 639 | 3.73 / 70.79 | 1 | 1 |
5 | 13 | 124.92 | 29 | 14.65 | 475 | 202 | 3.93 / 70.99 | 1 | 1 |
6 | 8 | 0.12 | 190 | 14.64 | 247 | 687 | 4.62 / 71.68 | 1 | 1 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 24 | 14.93 | 412 | 148 | 0.15 / 62.59 | 1 | 1 |
2 | 7 | 2004.44 | 42 | 13.26 | 3469 | 1932 | 2.08 / 64.52 | 1 | 1 |
3 | 13 | 1487.12 | 29 | 13.55 | 2654 | 1043 | 3.12 / 65.56 | 1 | 1 |
4 | 13 | 761.68 | 29 | 14.00 | 1525 | 619 | 3.74 / 66.18 | 1 | 1 |
5 | 13 | 111.44 | 29 | 14.69 | 449 | 191 | 3.93 / 66.37 | 1 | 1 |
6 | 8 | 0.04 | 190 | 14.65 | 246 | 685 | 4.62 / 67.06 | 1 | 1 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 24 | 14.93 | 418 | 150 | 0.15 / 58.07 | 1 | 1 |
2 | 7 | 2003.00 | 42 | 13.26 | 3472 | 1934 | 2.08 / 60.00 | 1 | 1 |
3 | 13 | 1511.88 | 29 | 13.54 | 2663 | 1046 | 3.13 / 61.05 | 1 | 1 |
4 | 13 | 536.28 | 29 | 14.17 | 1172 | 482 | 3.61 / 61.53 | 1 | 1 |
5 | 13 | 129.48 | 29 | 14.63 | 493 | 209 | 3.82 / 61.74 | 1 | 1 |
6 | 8 | 0.16 | 190 | 14.62 | 251 | 697 | 4.52 / 62.44 | 1 | 1 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 23 | 14.93 | 418 | 144 | 0.14 / 53.43 | 1 | 1 |
2 | 7 | 1999.04 | 43 | 13.26 | 3438 | 1960 | 2.10 / 55.39 | 1 | 1 |
3 | 13 | 1616.92 | 29 | 13.48 | 2841 | 1111 | 3.21 / 56.50 | 1 | 1 |
4 | 13 | 629.76 | 29 | 14.10 | 1315 | 538 | 3.75 / 57.04 | 1 | 1 |
5 | 13 | 108.24 | 29 | 14.68 | 448 | 191 | 3.94 / 57.23 | 1 | 1 |
6 | 8 | 0.08 | 190 | 14.64 | 248 | 690 | 4.63 / 57.92 | 1 | 1 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 23 | 14.92 | 420 | 144 | 0.14 / 48.64 | 1 | 1 |
2 | 7 | 2002.36 | 47 | 13.21 | 3438 | 2135 | 2.28 / 50.78 | 1 | 1 |
3 | 13 | 1345.52 | 28 | 13.62 | 2409 | 919 | 3.20 / 51.70 | 1 | 1 |
4 | 13 | 788.88 | 28 | 13.98 | 1561 | 611 | 3.81 / 52.31 | 1 | 1 |
5 | 13 | 93.08 | 28 | 14.72 | 420 | 173 | 3.98 / 52.48 | 1 | 1 |
6 | 13 | 22.32 | 28 | 14.81 | 287 | 119 | 4.10 / 52.60 | 1 | 1 |
7 | 8 | 0.04 | 190 | 14.60 | 248 | 688 | 4.79 / 53.29 | 1 | 1 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 23 | 14.93 | 420 | 144 | 0.14 / 44.18 | 1 | 1 |
2 | 7 | 2000.72 | 46 | 13.22 | 3425 | 2083 | 2.23 / 46.26 | 1 | 1 |
3 | 13 | 1251.12 | 28 | 13.65 | 2281 | 872 | 3.10 / 47.13 | 1 | 1 |
4 | 13 | 552.92 | 28 | 14.16 | 1196 | 474 | 3.57 / 47.61 | 1 | 1 |
5 | 13 | 121.76 | 28 | 14.65 | 479 | 196 | 3.77 / 47.80 | 1 | 1 |
6 | 8 | 0.20 | 190 | 14.61 | 251 | 697 | 4.47 / 48.50 | 1 | 1 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 23 | 14.94 | 418 | 144 | 0.14 / 39.60 | 1 | 1 |
2 | 7 | 2000.40 | 46 | 13.20 | 3461 | 2102 | 2.25 / 41.70 | 1 | 1 |
3 | 13 | 1356.84 | 28 | 13.60 | 2420 | 922 | 3.17 / 42.62 | 1 | 1 |
4 | 13 | 652.96 | 28 | 14.08 | 1354 | 534 | 3.70 / 43.16 | 1 | 1 |
5 | 13 | 112.80 | 28 | 14.69 | 460 | 189 | 3.89 / 43.35 | 1 | 1 |
6 | 8 | 0.04 | 190 | 14.63 | 247 | 687 | 4.58 / 44.03 | 1 | 1 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 23 | 14.94 | 416 | 143 | 0.14 / 35.02 | 1 | 1 |
2 | 7 | 2000.80 | 44 | 13.22 | 3436 | 1999 | 2.14 / 37.02 | 1 | 1 |
3 | 13 | 1602.68 | 29 | 13.47 | 2802 | 1095 | 3.24 / 38.12 | 1 | 1 |
4 | 13 | 498.00 | 29 | 14.21 | 1105 | 455 | 3.69 / 38.57 | 1 | 1 |
5 | 13 | 109.08 | 29 | 14.67 | 453 | 193 | 3.88 / 38.77 | 1 | 1 |
6 | 8 | -0.04 | 190 | 14.62 | 249 | 692 | 4.58 / 39.46 | 1 | 1 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 23 | 14.95 | 416 | 143 | 0.14 / 30.42 | 1 | 1 |
2 | 7 | 1988.08 | 43 | 13.22 | 3413 | 1940 | 2.08 / 32.36 | 1 | 1 |
3 | 13 | 1738.08 | 29 | 13.42 | 3005 | 1169 | 3.25 / 33.53 | 1 | 1 |
4 | 13 | 506.84 | 29 | 14.20 | 1121 | 462 | 3.71 / 34.00 | 1 | 1 |
5 | 13 | 121.28 | 29 | 14.65 | 474 | 201 | 3.92 / 34.20 | 1 | 1 |
6 | 8 | 0.04 | 190 | 14.60 | 247 | 685 | 4.60 / 34.88 | 1 | 1 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 23 | 14.95 | 400 | 138 | 0.14 / 25.76 | 1 | 1 |
2 | 7 | 1998.76 | 43 | 13.19 | 3419 | 1939 | 2.08 / 27.70 | 1 | 1 |
3 | 13 | 1757.72 | 29 | 13.39 | 3054 | 1186 | 3.26 / 28.88 | 1 | 1 |
4 | 13 | 612.40 | 29 | 14.10 | 1296 | 530 | 3.79 / 29.41 | 1 | 1 |
5 | 13 | 119.40 | 29 | 14.67 | 459 | 195 | 3.99 / 29.61 | 1 | 1 |
6 | 8 | 0.24 | 190 | 14.63 | 242 | 673 | 4.66 / 30.28 | 1 | 1 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 22 | 14.91 | 412 | 135 | 0.14 / 21.20 | 1 | 1 |
2 | 3 | 1036.84 | 1 | 14.62 | 2042 | 30 | 0.16 / 21.23 | 1 | 1 |
3 | 3 | 1019.00 | 1 | 14.60 | 2023 | 30 | 0.19 / 21.26 | 1 | 1 |
4 | 7 | 1985.08 | 46 | 13.14 | 3402 | 2056 | 2.25 / 23.31 | 1 | 1 |
5 | 13 | 1441.56 | 26 | 13.53 | 2551 | 897 | 3.15 / 24.21 | 1 | 1 |
6 | 13 | 725.28 | 26 | 14.01 | 1462 | 533 | 3.68 / 24.74 | 1 | 1 |
7 | 13 | 144.08 | 26 | 14.60 | 521 | 198 | 3.88 / 24.94 | 1 | 1 |
8 | 8 | 0.08 | 190 | 14.62 | 245 | 681 | 4.56 / 25.62 | 1 | 1 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 24 | 14.91 | 410 | 147 | 0.15 / 16.76 | 1 | 1 |
2 | 3 | 928.84 | -1 | 15.52 | 0 | 0 | 0.00 / 16.76 | 1 | 1 |
3 | 3 | 959.84 | -1 | 15.51 | 0 | 0 | 0.00 / 16.76 | 1 | 1 |
4 | 7 | 1977.64 | 46 | 13.10 | 3401 | 2049 | 2.20 / 18.81 | 1 | 1 |
5 | 13 | 1310.80 | 26 | 13.57 | 2331 | 822 | 3.02 / 19.63 | 1 | 1 |
6 | 13 | 513.40 | 26 | 14.18 | 1126 | 415 | 3.43 / 20.04 | 1 | 1 |
7 | 13 | 134.08 | 26 | 14.63 | 495 | 188 | 3.62 / 20.23 | 1 | 1 |
8 | 13 | 67.72 | 26 | 14.71 | 367 | 140 | 3.76 / 20.37 | 1 | 1 |
9 | 8 | 0.12 | 190 | 14.55 | 249 | 688 | 4.45 / 21.06 | 1 | 1 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 25 | 14.87 | 410 | 152 | 0.15 / 12.83 | 1 | 1 |
2 | 3 | 932.64 | -1 | 15.52 | 0 | 0 | 0.00 / 12.83 | 1 | 1 |
3 | 7 | 1510.08 | 45 | 13.36 | 2619 | 1575 | 1.73 / 14.40 | 1 | 1 |
4 | 13 | 1268.68 | 26 | 13.60 | 2271 | 803 | 2.53 / 15.21 | 1 | 1 |
5 | 13 | 566.60 | 26 | 14.09 | 1212 | 444 | 2.97 / 15.65 | 1 | 1 |
6 | 13 | 85.72 | 26 | 14.70 | 404 | 154 | 3.13 / 15.80 | 1 | 1 |
7 | 13 | 44.04 | 26 | 14.71 | 323 | 124 | 3.25 / 15.93 | 1 | 1 |
8 | 8 | 0.08 | 190 | 14.53 | 247 | 682 | 3.93 / 16.61 | 1 | 1 |
Average= | 3.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 22 | 14.85 | 412 | 135 | 0.13 / 8.78 | 1 | 1 |
2 | 10 | 1003.20 | 3 | 14.58 | 1926 | 84 | 0.22 / 8.87 | 1 | 1 |
3 | 3 | 970.72 | -1 | 15.50 | 0 | 0 | 0.08 / 8.87 | 1 | 1 |
4 | 3 | 1034.00 | 1 | 14.51 | 2020 | 29 | 0.25 / 8.90 | 1 | 1 |
5 | 7 | 1514.12 | 45 | 13.31 | 2632 | 1576 | 1.82 / 10.47 | 1 | 1 |
6 | 13 | 1400.68 | 26 | 13.49 | 2462 | 864 | 2.69 / 11.34 | 1 | 1 |
7 | 13 | 429.72 | 26 | 14.18 | 995 | 367 | 3.05 / 11.70 | 1 | 1 |
8 | 13 | 88.36 | 26 | 14.64 | 416 | 158 | 3.21 / 11.86 | 1 | 1 |
9 | 13 | 45.92 | 26 | 14.66 | 333 | 127 | 3.34 / 11.99 | 1 | 1 |
10 | 8 | 0.00 | 190 | 14.48 | 250 | 688 | 4.03 / 12.68 | 1 | 2 |
Average= | 3.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 24 | 14.73 | 395 | 140 | 0.14 / 4.62 | 1 | 1 |
2 | 3 | 911.00 | -2 | 15.50 | 0 | 0 | 0.00 / 4.62 | 1 | 1 |
3 | 7 | 1505.84 | 74 | 12.98 | 2581 | 2479 | 2.62 / 7.10 | 1 | 1 |
4 | 13 | 522.32 | 25 | 14.02 | 1145 | 401 | 3.02 / 7.50 | 1 | 1 |
5 | 13 | 125.00 | 25 | 14.51 | 489 | 177 | 3.20 / 7.67 | 1 | 1 |
6 | 13 | 27.32 | 25 | 14.69 | 300 | 110 | 3.31 / 7.78 | 1 | 1 |
7 | 8 | 0.04 | 240 | 14.41 | 250 | 865 | 4.17 / 8.65 | 1 | 40 |
Average= | 2.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 24 | 14.82 | 406 | 144 | 0.14 / 1.58 | 1 | 2 |
2 | 3 | 907.16 | -2 | 15.49 | 0 | 0 | 0.00 / 1.58 | 1 | 2 |
3 | 7 | 993.40 | 75 | 13.23 | 1804 | 1790 | 1.93 / 3.37 | 2 | 1 |
4 | 13 | 71.96 | 25 | 14.52 | 382 | 139 | 2.07 / 3.51 | 1 | 1 |
5 | 13 | 36.84 | 25 | 14.55 | 314 | 114 | 2.19 / 3.62 | 1 | 1 |
6 | 8 | 0.08 | 239 | 14.38 | 248 | 852 | 3.04 / 4.48 | 1 | 243 |
Average= | 2.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 76.64 | 24 | 14.56 | 361 | 126 | 0.13 / 0.13 | 1 | 1 |
2 | 7 | 87.08 | 74 | 14.41 | 377 | 402 | 0.53 / 0.53 | 1 | 1 |
3 | 13 | 45.92 | 25 | 14.69 | 308 | 113 | 0.64 / 0.64 | 1 | 2 |
4 | 8 | 0.08 | 240 | 14.60 | 227 | 795 | 1.44 / 1.44 | 1 | 31 |
Average= | 1.44 (KJ/cycle) |