SIO Argo Site:
Pump Diagnostics Page   



Serial= 8486 WMO= 5902494

Return

←PreviousNext→

Cycle 270 GMT 25/ 8/2023 9:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 34 10.79 409 150 0.15 / 1372.26 3 3
2 10 1002.68 3 8.49 1630 42 0.19 / 1372.30 3 3
3 3 1035.92 1 8.51 1686 14 0.21 / 1372.31 3 3
4 3 1029.80 1 8.61 1666 14 0.22 / 1372.33 3 3
5 12 1157.36 120 7.54 1812 1639 1.86 / 1373.97 3 3
6 7 1151.24 24 7.47 1800 323 2.18 / 1374.29 3 3
7 13 741.04 42 8.65 1265 460 2.64 / 1374.75 3 3
8 13 139.44 42 10.37 463 202 2.84 / 1374.95 3 3
9 8 -0.16 150 10.83 254 413 3.26 / 1375.36 3 4
Average= 5.08 (KJ/cycle)

Cycle 269 GMT 15/ 8/2023 15:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 37 11.08 404 166 0.17 / 1368.97 3 3
2 3 964.80 -1 12.41 0 0 0.00 / 1368.97 3 3
3 3 1048.12 1 9.03 1700 15 0.18 / 1368.98 3 3
4 12 1174.12 120 7.67 1838 1692 1.87 / 1370.67 3 3
5 7 1168.24 24 7.64 1827 335 2.21 / 1371.01 3 3
6 13 771.60 42 8.68 1334 486 2.69 / 1371.49 3 3
7 13 91.76 42 10.70 393 177 2.87 / 1371.67 3 3
8 8 -0.12 150 10.95 266 437 3.31 / 1372.11 3 3
Average= 5.08 (KJ/cycle)

Cycle 268 GMT 5/ 8/2023 21:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 32 11.23 404 145 0.15 / 1365.49 3 3
2 10 1036.56 4 9.49 1674 64 0.21 / 1365.55 3 3
3 3 1045.72 1 9.46 1715 16 0.22 / 1365.57 3 3
4 3 1032.00 1 9.50 1695 16 0.24 / 1365.58 3 3
5 12 1149.12 120 8.15 1817 1777 2.02 / 1367.36 3 3
6 7 1142.40 24 8.34 1804 361 2.38 / 1367.72 3 3
7 13 685.44 42 9.38 1226 483 2.86 / 1368.20 3 3
8 13 52.64 42 11.07 339 158 3.02 / 1368.36 3 3
9 8 0.00 150 11.19 261 438 3.46 / 1368.80 3 5
Average= 5.09 (KJ/cycle)

Cycle 267 GMT 27/ 7/2023 3:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 30 11.41 409 140 0.14 / 1358.36 3 3
2 10 1032.88 4 9.31 1671 62 0.20 / 1358.43 3 3
3 3 1081.60 2 9.07 1759 32 0.23 / 1358.46 3 3
4 3 1046.92 1 9.11 1704 16 0.25 / 1358.47 3 3
5 12 1136.48 3 8.87 1820 48 0.30 / 1358.52 3 3
6 12 2003.56 120 5.99 2754 1980 2.28 / 1360.50 3 3
7 7 2000.52 24 5.89 2514 355 2.63 / 1360.86 3 3
8 13 1938.88 42 6.27 2911 767 3.40 / 1361.62 3 3
9 13 1861.12 42 6.69 2785 783 4.18 / 1362.41 3 3
10 13 1750.56 42 7.04 2648 783 4.97 / 1363.19 3 3
11 13 1499.68 42 7.77 2322 758 5.72 / 1363.95 3 3
12 13 905.20 42 9.10 1531 585 6.31 / 1364.53 3 3
13 13 147.72 42 10.88 483 221 6.53 / 1364.75 3 3
14 13 30.92 42 11.20 308 145 6.67 / 1364.90 3 3
15 8 -0.20 150 11.22 265 446 7.12 / 1365.34 3 4
Average= 5.09 (KJ/cycle)

Cycle 266 GMT 25/ 7/2023 23:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 29 11.99 410 143 0.14 / 1354.96 3 3
2 10 1010.56 3 10.44 1677 53 0.20 / 1355.02 3 3
3 10 1043.64 3 10.39 1729 54 0.25 / 1355.07 3 3
4 12 1148.80 120 7.58 1802 1639 1.89 / 1356.71 3 3
5 7 1143.04 24 8.06 1813 351 2.24 / 1357.06 3 3
6 13 719.92 42 9.56 1272 511 2.75 / 1357.57 3 3
7 13 119.32 42 11.20 436 205 2.95 / 1357.78 3 3
8 8 0.00 150 11.50 259 447 3.40 / 1358.22 3 5
Average= 5.09 (KJ/cycle)

Cycle 265 GMT 16/ 7/2023 5:23: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 31 12.52 417 162 0.16 / 1350.28 3 3
2 3 1045.08 1 10.86 1731 19 0.18 / 1350.30 3 3
3 12 1133.40 120 5.60 1703 1144 1.33 / 1351.45 3 3
4 7 1139.44 24 8.08 1822 353 1.68 / 1351.80 3 3
5 13 1247.36 42 7.67 1943 626 2.30 / 1352.43 3 3
6 13 1202.56 42 8.28 1891 658 2.96 / 1353.08 3 3
7 13 1074.76 42 8.86 1734 645 3.61 / 1353.73 3 3
8 13 491.84 42 10.63 978 437 4.04 / 1354.17 3 3
9 13 46.40 42 11.97 339 170 4.21 / 1354.34 3 3
10 8 -0.08 150 11.93 271 485 4.70 / 1354.82 3 4
Average= 5.09 (KJ/cycle)

Cycle 264 GMT 6/ 7/2023 10:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 28 13.17 418 154 0.15 / 1346.79 3 3
2 3 1063.08 2 11.67 1778 41 0.20 / 1346.84 3 3
3 3 1043.28 1 11.57 1748 20 0.22 / 1346.86 3 3
4 12 1136.96 120 7.34 1785 1572 1.79 / 1348.43 3 3
5 7 1130.44 24 9.37 1812 407 2.20 / 1348.84 3 3
6 13 723.64 42 10.62 1299 579 2.77 / 1349.41 3 3
7 13 65.24 42 12.43 375 196 2.97 / 1349.61 3 3
8 8 -0.04 150 12.51 273 512 3.48 / 1350.12 3 4
Average= 5.09 (KJ/cycle)

Cycle 263 GMT 26/ 6/2023 16:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 28 13.50 426 161 0.16 / 1340.80 3 3
2 3 1047.20 1 11.64 1766 21 0.18 / 1340.82 3 3
3 3 1021.48 1 11.32 1730 20 0.20 / 1340.84 3 3
4 12 1124.80 3 11.37 1863 64 0.26 / 1340.91 3 3
5 12 2004.36 120 7.50 2964 2668 2.93 / 1343.57 3 3
6 7 1997.60 24 8.56 3031 623 3.56 / 1344.20 3 3
7 13 1567.24 42 9.64 2449 992 4.55 / 1345.19 2 3
8 13 804.88 42 11.24 1428 674 5.22 / 1345.86 3 3
9 13 63.20 42 13.01 384 210 5.43 / 1346.07 3 4
10 8 -0.12 150 13.00 291 567 6.00 / 1346.64 3 6
Average= 5.10 (KJ/cycle)

Cycle 262 GMT 25/ 6/2023 12:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 28 13.89 422 164 0.16 / 1336.21 3 3
2 3 1023.56 1 11.52 1735 20 0.18 / 1336.23 3 3
3 12 1158.84 120 5.57 1635 1093 1.28 / 1337.32 3 3
4 7 1164.80 24 9.37 1876 422 1.70 / 1337.74 3 3
5 13 1242.12 42 8.59 1954 705 2.40 / 1338.45 3 3
6 13 1160.20 42 9.21 1855 718 3.12 / 1339.16 3 3
7 13 899.36 42 10.47 1525 671 3.79 / 1339.83 3 3
8 13 84.68 42 13.27 416 232 4.02 / 1340.07 3 4
9 8 -0.04 150 13.40 286 575 4.60 / 1340.64 3 5
Average= 5.10 (KJ/cycle)

Cycle 261 GMT 15/ 6/2023 17:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 28 14.11 425 168 0.17 / 1331.44 3 3
2 12 1156.68 120 5.57 1612 1077 1.25 / 1332.52 3 3
3 7 1162.96 24 9.47 1880 427 1.67 / 1332.95 3 3
4 13 1244.52 42 8.70 1957 715 2.39 / 1333.66 3 3
5 13 1166.64 42 9.68 1869 760 3.15 / 1334.42 3 3
6 13 1040.20 42 10.42 1725 755 3.90 / 1335.18 3 3
7 13 107.56 42 13.57 461 263 4.17 / 1335.44 3 4
8 8 0.08 150 13.80 291 602 4.77 / 1336.04 3 8
Average= 5.10 (KJ/cycle)

Cycle 260 GMT 5/ 6/2023 22:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 28 14.21 434 173 0.17 / 1327.89 3 3
2 12 1134.00 120 6.54 1764 1384 1.56 / 1329.27 3 3
3 7 1129.28 24 10.06 1827 441 2.00 / 1329.72 3 3
4 13 871.32 42 11.36 1511 721 2.72 / 1330.44 3 3
5 13 68.32 42 13.90 395 231 2.95 / 1330.67 3 5
6 8 -0.16 150 14.03 289 608 3.56 / 1331.28 3 11
Average= 5.10 (KJ/cycle)

Cycle 259 GMT 27/ 5/2023 4:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 28 14.22 433 172 0.17 / 1322.14 3 3
2 12 1121.48 3 11.27 1851 63 0.23 / 1322.20 3 3
3 12 1992.80 120 8.14 3003 2933 3.17 / 1325.14 3 3
4 7 1984.44 25 9.85 3033 747 3.92 / 1325.88 3 3
5 13 1159.32 42 11.91 1926 963 4.88 / 1326.85 3 3
6 13 65.56 42 14.03 403 237 5.12 / 1327.09 3 5
7 8 0.04 150 14.13 298 632 5.75 / 1327.72 3 9
Average= 5.11 (KJ/cycle)

Cycle 258 GMT 26/ 5/2023 1:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 28 14.22 451 180 0.18 / 1317.35 3 3
2 12 1146.96 120 5.55 1551 1033 1.21 / 1318.38 3 3
3 7 1152.24 24 9.54 1865 427 1.64 / 1318.81 3 3
4 13 1226.32 42 9.34 1947 764 2.40 / 1319.58 3 3
5 13 1162.92 42 10.28 1872 808 3.21 / 1320.38 3 3
6 13 867.20 42 11.71 1505 740 3.95 / 1321.12 3 3
7 13 47.04 42 14.07 369 218 4.17 / 1321.34 3 5
8 8 0.04 150 14.19 295 628 4.80 / 1321.97 3 8
Average= 5.10 (KJ/cycle)

Cycle 257 GMT 16/ 5/2023 7: 7: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 28 14.28 425 170 0.17 / 1312.49 3 3
2 12 1145.68 120 5.57 1624 1085 1.26 / 1313.57 3 3
3 7 1151.76 24 9.62 1871 432 1.69 / 1314.00 3 3
4 13 1231.96 42 9.58 1956 787 2.47 / 1314.79 3 3
5 13 1146.20 42 10.52 1865 824 3.30 / 1315.62 3 3
6 13 727.20 42 12.29 1331 687 3.99 / 1316.30 3 3
7 13 40.08 42 14.11 363 215 4.20 / 1316.52 3 5
8 8 -0.04 150 14.17 308 655 4.86 / 1317.17 3 9
Average= 5.11 (KJ/cycle)

Cycle 256 GMT 6/ 5/2023 12:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 28 14.32 429 172 0.17 / 1308.85 3 3
2 12 1134.68 120 6.60 1763 1396 1.57 / 1310.25 3 3
3 7 1129.80 24 10.19 1831 448 2.02 / 1310.70 3 3
4 13 868.92 42 11.81 1516 752 2.77 / 1311.45 3 3
5 13 51.52 42 14.05 383 226 2.99 / 1311.68 3 5
6 8 0.08 150 14.22 300 640 3.63 / 1312.32 3 11
Average= 5.11 (KJ/cycle)

Cycle 255 GMT 26/ 4/2023 18:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 28 14.27 422 169 0.17 / 1303.22 3 3
2 12 1121.40 3 11.09 1853 62 0.23 / 1303.28 3 3
3 12 1992.40 120 8.12 2996 2919 3.15 / 1306.20 3 3
4 7 1984.00 25 10.13 3032 768 3.92 / 1306.96 3 3
5 13 898.28 42 12.71 1580 843 4.76 / 1307.81 3 4
6 13 49.16 42 14.16 382 227 4.99 / 1308.03 3 5
7 8 -0.08 150 14.30 302 648 5.64 / 1308.68 3 10
Average= 5.11 (KJ/cycle)

Cycle 254 GMT 25/ 4/2023 15:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 28 14.29 429 172 0.17 / 1298.53 3 3
2 12 1126.16 120 5.58 1618 1083 1.26 / 1299.61 3 3
3 7 1132.60 24 9.81 1846 435 1.69 / 1300.05 3 3
4 13 1207.04 42 10.20 1933 828 2.52 / 1300.88 3 3
5 13 1106.24 42 10.97 1812 835 3.35 / 1301.71 3 3
6 13 413.44 42 13.27 904 504 3.86 / 1302.21 3 4
7 13 22.52 42 14.21 330 197 4.05 / 1302.41 3 5
8 8 0.04 150 14.27 297 636 4.69 / 1303.05 3 9
Average= 5.11 (KJ/cycle)

Cycle 253 GMT 15/ 4/2023 20:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 28 14.31 428 171 0.17 / 1293.79 3 3
2 12 1143.48 120 5.59 1690 1134 1.31 / 1294.92 3 3
3 7 1149.92 24 9.83 1863 440 1.74 / 1295.36 3 3
4 13 1230.00 42 10.16 1962 837 2.58 / 1296.20 3 3
5 13 1129.00 42 10.98 1838 848 3.43 / 1297.05 3 3
6 13 385.56 42 13.33 865 484 3.91 / 1297.53 3 4
7 13 19.04 42 14.20 327 195 4.11 / 1297.73 3 5
8 8 -0.16 150 14.29 294 630 4.74 / 1298.36 3 9
Average= 5.11 (KJ/cycle)

Cycle 252 GMT 6/ 4/2023 1:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 28 14.35 438 176 0.18 / 1290.09 3 3
2 12 1110.36 120 7.00 1739 1461 1.64 / 1291.55 3 3
3 7 1105.44 24 10.45 1802 452 2.09 / 1292.00 3 3
4 13 831.84 42 12.15 1471 751 2.84 / 1292.75 3 3
5 13 46.12 42 14.11 369 219 3.06 / 1292.97 3 5
6 8 0.00 150 14.28 302 647 3.70 / 1293.62 3 9
Average= 5.11 (KJ/cycle)

Cycle 251 GMT 27/ 3/2023 8: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 28 14.25 442 176 0.18 / 1284.51 3 3
2 12 1115.60 3 11.20 1843 62 0.24 / 1284.57 3 3
3 12 1992.72 120 8.28 3004 2985 3.22 / 1287.55 3 3
4 7 1983.88 24 10.30 3031 749 3.97 / 1288.30 3 3
5 13 726.48 42 13.10 1340 737 4.71 / 1289.04 3 4
6 13 46.16 42 14.19 379 226 4.94 / 1289.26 3 5
7 8 0.08 150 14.34 302 650 5.59 / 1289.91 3 11
Average= 5.12 (KJ/cycle)

Cycle 250 GMT 26/ 3/2023 5:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 28 14.25 446 178 0.18 / 1279.57 3 3
2 12 1143.00 120 5.58 1656 1109 1.29 / 1280.68 3 3
3 7 1150.52 24 10.01 1874 450 1.74 / 1281.13 3 3
4 13 1230.40 42 10.54 1970 872 2.61 / 1282.00 3 3
5 13 1135.04 42 11.13 1870 874 3.48 / 1282.88 3 3
6 13 548.52 42 13.06 1090 598 4.08 / 1283.48 3 4
7 13 18.72 42 14.18 331 197 4.28 / 1283.67 3 5
8 8 0.04 150 14.27 306 655 4.93 / 1284.33 3 11
Average= 5.12 (KJ/cycle)

Cycle 249 GMT 16/ 3/2023 11: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 28 14.23 442 176 0.18 / 1274.68 3 3
2 12 1120.32 120 5.59 1710 1147 1.32 / 1275.83 3 3
3 7 1125.48 24 10.01 1831 440 1.76 / 1276.27 3 3
4 13 1195.00 42 10.59 1915 852 2.61 / 1277.12 3 3
5 13 1109.44 42 11.18 1818 854 3.47 / 1277.97 3 3
6 13 517.88 42 13.11 1051 579 4.05 / 1278.55 3 4
7 13 16.08 42 14.18 331 197 4.24 / 1278.75 3 5
8 8 0.00 150 14.29 301 645 4.89 / 1279.40 3 9
Average= 5.12 (KJ/cycle)

Cycle 248 GMT 6/ 3/2023 16:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 28 14.30 456 183 0.18 / 1270.84 3 3
2 3 972.36 -1 15.20 0 0 0.00 / 1270.84 3 3
3 3 1043.52 1 11.41 1731 20 0.20 / 1270.86 3 3
4 12 1151.16 120 6.61 1778 1410 1.61 / 1272.27 3 3
5 7 1146.96 24 10.48 1855 467 2.08 / 1272.73 3 3
6 13 1032.04 42 11.60 1743 849 2.93 / 1273.58 3 3
7 13 108.04 42 14.01 470 277 3.20 / 1273.86 3 5
8 8 0.00 150 14.30 302 648 3.85 / 1274.51 3 9
Average= 5.12 (KJ/cycle)

Cycle 247 GMT 24/ 2/2023 22:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 28 14.23 441 176 0.18 / 1265.11 3 3
2 12 1105.68 3 11.11 1815 60 0.24 / 1265.17 3 3
3 12 1998.92 120 7.93 2999 2854 3.09 / 1268.03 3 3
4 7 1992.64 24 10.29 3048 753 3.84 / 1268.78 3 3
5 13 1081.28 42 12.56 1834 967 4.81 / 1269.75 3 4
6 13 55.64 42 14.15 396 235 5.05 / 1269.98 3 5
7 8 0.04 150 14.32 312 670 5.72 / 1270.65 3 11
Average= 5.12 (KJ/cycle)

Cycle 246 GMT 23/ 2/2023 19: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 28 14.18 454 180 0.18 / 1260.30 3 3
2 12 1107.48 120 5.58 1654 1108 1.29 / 1261.41 3 3
3 7 1114.28 24 10.19 1821 445 1.73 / 1261.85 3 3
4 13 1211.72 42 10.78 1950 883 2.62 / 1262.73 3 3
5 13 1092.48 42 11.35 1821 868 3.48 / 1263.60 3 3
6 13 368.04 42 13.51 840 477 3.96 / 1264.08 3 4
7 13 26.92 42 14.17 349 208 4.17 / 1264.29 3 6
8 8 -0.08 150 14.28 304 651 4.82 / 1264.94 3 12
Average= 5.12 (KJ/cycle)

Cycle 245 GMT 14/ 2/2023 0:33: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 28 14.18 459 182 0.18 / 1255.33 3 3
2 12 1149.36 120 5.59 1681 1128 1.31 / 1256.45 3 3
3 7 1155.76 24 9.94 1867 445 1.76 / 1256.90 3 3
4 13 1227.68 42 10.52 1971 871 2.63 / 1257.77 3 3
5 13 1130.76 42 11.11 1875 875 3.50 / 1258.65 3 3
6 13 551.08 42 13.09 1093 601 4.10 / 1259.25 3 4
7 13 33.00 42 14.14 361 214 4.32 / 1259.46 3 5
8 8 -0.04 150 14.26 307 657 4.97 / 1260.12 3 11
Average= 5.12 (KJ/cycle)

Cycle 244 GMT 4/ 2/2023 5:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 28 14.25 443 177 0.18 / 1251.58 3 3
2 12 1144.76 120 6.74 1767 1429 1.61 / 1253.01 3 3
3 7 1140.68 24 10.51 1852 467 2.07 / 1253.47 3 3
4 13 883.12 42 12.17 1538 786 2.86 / 1254.26 3 3
5 13 57.84 42 14.09 393 233 3.09 / 1254.49 3 5
6 8 0.04 150 14.27 305 653 3.74 / 1255.14 3 12
Average= 5.12 (KJ/cycle)

Cycle 243 GMT 25/ 1/2023 11:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 28 14.20 439 175 0.17 / 1245.89 3 3
2 12 1116.12 3 11.02 1836 61 0.24 / 1245.95 3 3
3 12 1991.84 120 7.85 2993 2819 3.05 / 1248.77 3 3
4 7 1983.56 24 10.44 3027 758 3.81 / 1249.53 3 3
5 13 1073.60 42 12.62 1821 965 4.78 / 1250.50 3 5
6 13 52.56 42 14.15 394 234 5.01 / 1250.73 3 5
7 8 0.00 150 14.29 313 671 5.68 / 1251.40 3 10
Average= 5.13 (KJ/cycle)

Cycle 242 GMT 24/ 1/2023 8:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 28 14.17 440 175 0.17 / 1241.19 3 3
2 12 1142.44 120 5.58 1652 1106 1.28 / 1242.30 3 3
3 7 1149.64 24 10.17 1863 455 1.74 / 1242.75 3 3
4 13 1233.28 42 10.91 1970 903 2.64 / 1243.66 3 3
5 13 1128.12 42 11.43 1862 894 3.53 / 1244.55 3 3
6 13 415.16 42 13.47 905 512 4.04 / 1245.06 3 4
7 8 0.08 150 14.27 306 655 4.70 / 1245.72 3 10
Average= 5.13 (KJ/cycle)

Cycle 241 GMT 14/ 1/2023 14:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 28 14.22 422 168 0.17 / 1236.38 3 3
2 12 1143.48 120 5.58 1658 1110 1.28 / 1237.49 3 3
3 7 1149.92 24 10.01 1855 446 1.72 / 1237.93 3 3
4 13 1235.48 42 10.57 1969 874 2.60 / 1238.81 3 3
5 13 1133.20 42 11.19 1861 875 3.47 / 1239.68 3 3
6 13 403.48 42 13.46 883 499 3.97 / 1240.18 3 4
7 13 15.80 42 14.16 323 192 4.16 / 1240.37 3 6
8 8 -0.04 150 14.24 302 645 4.81 / 1241.02 3 13
Average= 5.13 (KJ/cycle)

Cycle 240 GMT 4/ 1/2023 19:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 28 14.23 450 179 0.18 / 1232.69 3 3
2 12 1127.52 120 6.70 1744 1402 1.58 / 1234.10 3 3
3 7 1123.08 24 10.56 1853 470 2.05 / 1234.57 3 3
4 13 857.64 42 12.31 1504 778 2.83 / 1235.34 3 3
5 13 43.48 42 14.11 370 219 3.05 / 1235.56 3 5
6 8 0.04 150 14.26 302 646 3.69 / 1236.21 3 11
Average= 5.13 (KJ/cycle)

Cycle 239 GMT 26/12/2022 1:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 28 14.18 429 170 0.17 / 1227.09 3 3
2 12 1100.12 3 11.03 1811 60 0.23 / 1227.15 3 3
3 12 1995.76 120 7.64 2992 2743 2.97 / 1229.90 3 3
4 7 1988.12 24 10.44 3029 759 3.73 / 1230.66 3 3
5 13 1086.32 42 12.62 1831 971 4.70 / 1231.63 3 4
6 13 55.08 42 14.14 390 232 4.93 / 1231.86 3 6
7 8 0.08 150 14.29 306 656 5.59 / 1232.51 3 10
Average= 5.14 (KJ/cycle)

Cycle 238 GMT 24/12/2022 22:52:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 28 14.23 419 167 0.17 / 1222.56 3 3
2 12 1126.92 120 5.58 1656 1109 1.28 / 1223.67 3 3
3 7 1133.00 24 10.36 1848 459 1.74 / 1224.13 3 3
4 13 1209.84 42 11.14 1944 910 2.64 / 1225.04 3 3
5 13 1104.96 42 11.63 1821 889 3.53 / 1225.93 3 3
6 13 218.60 42 13.83 620 360 3.89 / 1226.29 3 4
7 8 0.08 150 14.27 296 634 4.53 / 1226.92 3 9
Average= 5.13 (KJ/cycle)

Cycle 237 GMT 15/12/2022 4:17: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 28 14.19 445 177 0.18 / 1217.75 3 3
2 12 1143.88 120 5.58 1626 1089 1.27 / 1218.84 3 3
3 7 1149.84 24 10.09 1866 452 1.72 / 1219.29 3 3
4 13 1217.60 42 10.76 1951 882 2.60 / 1220.17 3 3
5 13 1124.84 42 11.34 1847 880 3.48 / 1221.05 3 3
6 13 414.92 42 13.47 901 510 3.99 / 1221.56 3 4
7 13 13.60 42 14.17 323 192 4.18 / 1221.76 3 5
8 8 0.00 150 14.24 300 641 4.82 / 1222.40 3 9
Average= 5.14 (KJ/cycle)

Cycle 236 GMT 5/12/2022 9:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 28 14.25 437 174 0.17 / 1213.95 3 3
2 12 1129.56 120 6.80 1752 1430 1.60 / 1215.38 3 3
3 7 1126.04 24 10.60 1828 465 2.07 / 1215.85 3 3
4 13 1013.92 42 11.81 1715 851 2.92 / 1216.70 3 3
5 13 48.12 42 14.11 377 223 3.14 / 1216.92 3 5
6 8 -0.04 150 14.26 305 652 3.80 / 1217.58 3 11
Average= 5.14 (KJ/cycle)

Cycle 235 GMT 25/11/2022 15:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 28 14.16 451 179 0.18 / 1208.38 3 3
2 12 1115.32 3 10.87 1817 59 0.24 / 1208.44 3 3
3 12 1993.00 120 7.61 2992 2732 2.97 / 1211.18 3 3
4 7 1985.36 24 10.47 3042 764 3.73 / 1211.94 3 3
5 13 1049.24 42 12.69 1794 956 4.69 / 1212.90 3 4
6 13 49.24 42 14.16 381 227 4.92 / 1213.12 3 5
7 8 0.00 150 14.30 306 656 5.57 / 1213.78 3 11
Average= 5.14 (KJ/cycle)

Cycle 234 GMT 24/11/2022 12:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 28 14.16 445 176 0.18 / 1203.56 3 3
2 12 1133.00 120 5.57 1652 1104 1.28 / 1204.66 3 3
3 7 1138.44 24 10.36 1847 459 1.74 / 1205.12 3 3
4 13 1205.24 42 11.19 1931 908 2.65 / 1206.03 3 3
5 13 1093.68 42 11.67 1809 887 3.53 / 1206.91 3 3
6 13 331.12 42 13.64 780 447 3.98 / 1207.36 3 4
7 13 25.16 42 14.16 337 200 4.18 / 1207.56 3 5
8 8 -0.04 150 14.26 301 644 4.83 / 1208.21 3 10
Average= 5.14 (KJ/cycle)

Cycle 233 GMT 14/11/2022 18:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 28 14.18 422 168 0.17 / 1198.78 3 3
2 12 1137.08 120 5.58 1623 1087 1.25 / 1199.87 3 3
3 7 1143.48 24 10.10 1860 451 1.71 / 1200.32 3 3
4 13 1215.92 42 10.78 1948 882 2.59 / 1201.20 3 3
5 13 1122.20 42 11.37 1840 879 3.47 / 1202.08 3 3
6 13 387.08 42 13.51 860 488 3.95 / 1202.56 3 4
7 13 16.64 42 14.18 318 189 4.14 / 1202.75 3 5
8 8 -0.16 150 14.25 293 626 4.77 / 1203.38 3 10
Average= 5.14 (KJ/cycle)

Cycle 232 GMT 4/11/2022 23:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 28 14.23 437 174 0.17 / 1195.09 3 3
2 12 1128.56 120 6.66 1749 1398 1.57 / 1196.49 3 3
3 7 1123.96 24 10.51 1843 465 2.04 / 1196.95 3 3
4 13 851.12 42 12.34 1495 775 2.81 / 1197.73 3 3
5 13 106.96 42 14.00 459 270 3.08 / 1198.00 3 5
6 8 -0.16 150 14.28 286 613 3.69 / 1198.61 3 13
Average= 5.14 (KJ/cycle)

Cycle 231 GMT 26/10/2022 5:55: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 28 14.19 414 164 0.16 / 1189.48 3 3
2 12 1126.68 3 10.76 1842 59 0.22 / 1189.54 3 3
3 12 1992.92 120 7.42 2976 2650 2.87 / 1192.19 3 3
4 7 1985.24 24 10.49 3028 762 3.64 / 1192.95 3 3
5 13 1224.72 42 12.46 2021 1058 4.69 / 1194.01 3 3
6 13 125.36 42 14.05 486 287 4.98 / 1194.30 3 5
7 8 -0.04 150 14.31 288 618 5.60 / 1194.92 3 9
Average= 5.15 (KJ/cycle)

Cycle 230 GMT 25/10/2022 3: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 28 14.20 416 165 0.17 / 1184.99 3 3
2 12 1133.88 120 5.57 1611 1077 1.24 / 1186.07 3 3
3 7 1139.00 24 10.35 1856 461 1.70 / 1186.53 3 3
4 13 1203.20 42 11.16 1945 912 2.61 / 1187.44 3 3
5 13 1102.00 42 11.70 1821 895 3.51 / 1188.33 3 3
6 13 240.16 42 13.81 645 374 3.88 / 1188.71 3 4
7 8 0.08 150 14.29 285 611 4.49 / 1189.32 3 10
Average= 5.15 (KJ/cycle)

Cycle 229 GMT 15/10/2022 8:26: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 28 14.20 421 167 0.17 / 1180.40 3 3
2 12 1143.36 120 5.57 1598 1068 1.24 / 1181.47 3 3
3 7 1149.76 24 10.12 1865 453 1.69 / 1181.92 3 3
4 13 1219.36 42 10.86 1952 890 2.58 / 1182.81 3 3
5 13 1127.64 42 11.45 1864 896 3.48 / 1183.71 3 3
6 13 368.96 42 13.55 850 484 3.96 / 1184.19 3 4
7 8 -0.04 150 14.28 294 630 4.59 / 1184.82 3 6
Average= 5.15 (KJ/cycle)

Cycle 228 GMT 5/10/2022 13:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 28 14.24 435 173 0.17 / 1176.61 3 3
2 12 1129.80 120 6.82 1752 1434 1.61 / 1178.04 3 3
3 7 1125.40 24 10.58 1861 473 2.08 / 1178.51 3 3
4 13 993.36 42 11.93 1681 842 2.92 / 1179.36 3 3
5 13 81.64 42 14.06 419 247 3.17 / 1179.60 3 5
6 8 -0.04 150 14.27 295 631 3.80 / 1180.23 3 9
Average= 5.15 (KJ/cycle)

Cycle 227 GMT 25/ 9/2022 19:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 28 14.18 417 166 0.17 / 1171.03 3 3
2 12 1124.00 3 10.71 1840 59 0.22 / 1171.09 3 3
3 12 1994.44 120 7.36 2988 2639 2.86 / 1173.73 3 3
4 7 1986.92 24 10.54 3034 767 3.63 / 1174.49 3 3
5 13 1099.20 42 12.65 1865 991 4.62 / 1175.48 3 4
6 13 131.92 42 14.02 511 301 4.92 / 1175.79 3 5
7 8 -0.04 150 14.31 302 648 5.57 / 1176.43 3 9
Average= 5.16 (KJ/cycle)

Cycle 226 GMT 24/ 9/2022 16:48:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 28 14.18 428 170 0.17 / 1166.42 3 3
2 12 1138.44 120 5.58 1606 1075 1.25 / 1167.49 3 3
3 7 1144.04 24 10.41 1863 465 1.71 / 1167.96 3 3
4 13 1202.36 42 11.27 1937 917 2.63 / 1168.88 3 3
5 13 1107.68 42 11.79 1841 912 3.54 / 1169.79 3 3
6 13 343.88 42 13.63 804 460 4.00 / 1170.25 3 5
7 8 0.00 150 14.28 287 615 4.61 / 1170.86 3 10
Average= 5.16 (KJ/cycle)

Cycle 225 GMT 14/ 9/2022 22:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 28 14.20 424 169 0.17 / 1161.80 3 3
2 12 1139.00 120 5.57 1640 1096 1.26 / 1162.89 3 3
3 7 1144.48 24 10.24 1857 456 1.72 / 1163.35 3 3
4 13 1221.16 42 11.00 1955 903 2.62 / 1164.25 3 3
5 13 1117.28 42 11.63 1847 902 3.53 / 1165.15 3 3
6 13 348.20 42 13.60 813 464 3.99 / 1165.62 3 5
7 8 -0.16 150 14.27 294 629 4.62 / 1166.25 3 6
Average= 5.16 (KJ/cycle)

Cycle 224 GMT 5/ 9/2022 3:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 28 14.21 420 167 0.17 / 1158.09 3 3
2 12 1141.08 120 6.66 1770 1415 1.58 / 1159.51 3 3
3 7 1136.64 24 10.58 1878 477 2.06 / 1159.98 3 3
4 13 886.28 42 12.33 1543 799 2.86 / 1160.78 3 3
5 13 79.56 42 14.08 403 238 3.10 / 1161.02 3 4
6 8 0.00 150 14.29 283 607 3.70 / 1161.63 3 7
Average= 5.16 (KJ/cycle)

Cycle 223 GMT 26/ 8/2022 9:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 28 14.18 417 166 0.17 / 1152.63 3 3
2 12 1110.84 3 10.56 1805 57 0.22 / 1152.69 3 3
3 12 1995.36 120 7.22 2985 2586 2.81 / 1155.27 3 3
4 7 1988.48 24 10.60 3025 770 3.58 / 1156.04 3 3
5 13 1118.32 42 12.65 1879 998 4.58 / 1157.04 3 5
6 13 101.68 42 14.08 450 266 4.84 / 1157.31 3 5
7 8 -0.08 150 14.32 288 619 5.46 / 1157.93 3 7
Average= 5.17 (KJ/cycle)

Cycle 222 GMT 25/ 8/2022 6:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 28 14.21 431 171 0.17 / 1148.13 3 3
2 12 1132.32 120 5.57 1615 1079 1.25 / 1149.21 3 3
3 7 1138.68 24 10.41 1859 464 1.72 / 1149.67 3 3
4 13 1203.72 42 11.25 1937 915 2.63 / 1150.59 3 3
5 13 1099.40 42 11.86 1831 912 3.54 / 1151.50 3 3
6 13 203.72 42 13.85 599 348 3.89 / 1151.85 3 5
7 8 0.00 150 14.28 288 617 4.51 / 1152.46 3 10
Average= 5.17 (KJ/cycle)

Cycle 221 GMT 15/ 8/2022 11:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 28 14.18 430 171 0.17 / 1143.33 3 3
2 12 1123.72 120 5.58 1659 1111 1.28 / 1144.44 3 3
3 7 1129.08 24 10.33 1838 456 1.74 / 1144.89 3 3
4 13 1194.64 42 11.11 1926 899 2.64 / 1145.79 3 3
5 13 1087.84 42 11.77 1815 897 3.53 / 1146.69 3 3
6 13 331.68 42 13.63 787 451 3.98 / 1147.14 3 5
7 13 14.64 42 14.20 312 186 4.17 / 1147.33 3 4
8 8 -0.12 150 14.26 294 629 4.80 / 1147.96 3 9
Average= 5.17 (KJ/cycle)

Cycle 220 GMT 5/ 8/2022 17:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 28 14.21 434 173 0.17 / 1139.67 3 3
2 12 1116.48 120 7.02 1742 1467 1.64 / 1141.14 3 3
3 7 1111.96 24 10.69 1833 470 2.11 / 1141.61 3 3
4 13 710.84 42 12.84 1308 705 2.82 / 1142.32 3 5
5 13 50.60 42 14.10 367 217 3.03 / 1142.53 3 4
6 8 0.00 150 14.24 292 624 3.66 / 1143.16 3 8
Average= 5.17 (KJ/cycle)

Cycle 219 GMT 26/ 7/2022 23:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 28 14.19 427 170 0.17 / 1134.21 3 3
2 12 1104.00 3 10.53 1807 57 0.23 / 1134.27 3 3
3 12 1994.52 120 7.50 2999 2699 2.93 / 1136.97 3 3
4 7 1986.76 24 10.68 3035 778 3.70 / 1137.74 3 3
5 13 924.36 42 12.94 1614 877 4.58 / 1138.62 3 4
6 13 68.28 42 14.12 405 240 4.82 / 1138.86 3 5
7 8 0.00 150 14.30 298 639 5.46 / 1139.50 3 12
Average= 5.18 (KJ/cycle)

Cycle 218 GMT 25/ 7/2022 19:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 28 14.17 430 171 0.17 / 1129.41 3 3
2 12 1137.24 120 5.58 1621 1085 1.26 / 1130.50 3 3
3 7 1143.84 24 10.38 1869 466 1.72 / 1130.96 3 3
4 13 1231.08 42 11.16 1997 936 2.66 / 1131.90 3 3
5 13 1125.60 42 11.86 1875 934 3.59 / 1132.83 3 3
6 13 225.56 42 13.81 644 374 3.97 / 1133.21 3 5
7 13 17.84 42 14.18 324 193 4.16 / 1133.40 3 5
8 8 0.00 150 14.24 299 639 4.80 / 1134.04 3 10
Average= 5.18 (KJ/cycle)

Cycle 217 GMT 16/ 7/2022 1:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 28 14.14 428 169 0.17 / 1124.62 3 3
2 12 1140.00 120 5.59 1658 1112 1.28 / 1125.74 3 3
3 7 1145.96 24 10.29 1866 461 1.74 / 1126.20 3 3
4 13 1214.80 42 11.08 1952 908 2.65 / 1127.10 3 3
5 13 1126.96 42 11.76 1873 925 3.58 / 1128.03 3 3
6 13 245.40 42 13.77 667 386 3.96 / 1128.42 3 5
7 13 19.32 42 14.16 328 195 4.16 / 1128.61 3 5
8 8 0.00 150 14.25 296 633 4.79 / 1129.24 3 15
Average= 5.18 (KJ/cycle)

Cycle 216 GMT 6/ 7/2022 6:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 28 14.21 433 172 0.17 / 1120.95 3 3
2 12 1125.24 120 7.02 1751 1475 1.65 / 1122.43 3 3
3 7 1119.88 24 10.79 1818 471 2.12 / 1122.90 3 3
4 13 720.32 42 12.88 1314 711 2.83 / 1123.61 3 3
5 13 52.16 42 14.09 375 222 3.05 / 1123.83 3 4
6 8 0.00 150 14.24 292 624 3.67 / 1124.45 3 8
Average= 5.18 (KJ/cycle)

Cycle 215 GMT 26/ 6/2022 12:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 28 14.18 429 170 0.17 / 1115.28 3 3
2 12 1104.76 3 10.44 1798 56 0.23 / 1115.33 3 3
3 12 1994.28 120 7.74 2992 2779 3.01 / 1118.11 3 3
4 7 1986.28 24 10.74 3047 785 3.79 / 1118.90 3 3
5 13 1050.12 42 12.83 1793 966 4.76 / 1119.86 3 4
6 13 94.60 42 14.07 445 263 5.02 / 1120.13 3 5
7 8 0.04 150 14.30 304 652 5.67 / 1120.78 3 12
Average= 5.19 (KJ/cycle)

Cycle 214 GMT 25/ 6/2022 9:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 28 14.16 429 170 0.17 / 1110.38 3 3
2 12 1141.00 120 5.58 1645 1101 1.27 / 1111.48 3 3
3 7 1147.12 24 10.42 1864 466 1.74 / 1111.95 3 3
4 13 1213.56 42 11.37 1951 932 2.67 / 1112.88 3 3
5 13 1100.28 42 12.04 1833 927 3.60 / 1113.81 3 3
6 13 336.72 42 13.66 801 460 4.06 / 1114.27 3 5
7 13 27.84 42 14.16 341 203 4.26 / 1114.47 3 5
8 8 0.00 150 14.26 297 635 4.89 / 1115.11 3 8
Average= 5.19 (KJ/cycle)

Cycle 213 GMT 15/ 6/2022 15:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 28 14.14 443 175 0.18 / 1105.75 3 3
2 12 1141.96 120 5.62 1715 1157 1.33 / 1106.91 3 3
3 7 1148.24 24 10.42 1866 467 1.80 / 1107.37 3 3
4 13 1224.84 42 11.27 1963 929 2.73 / 1108.30 3 3
5 13 1119.48 42 11.95 1861 934 3.66 / 1109.24 3 3
6 13 204.68 42 13.85 604 351 4.01 / 1109.59 3 4
7 8 0.04 150 14.26 292 625 4.64 / 1110.21 3 8
Average= 5.19 (KJ/cycle)

Cycle 212 GMT 5/ 6/2022 20:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 28 14.20 443 176 0.18 / 1102.06 3 3
2 12 1156.28 120 7.15 1797 1542 1.72 / 1103.60 3 3
3 7 1151.20 24 10.89 1858 486 2.20 / 1104.09 3 3
4 13 605.04 42 13.17 1163 643 2.85 / 1104.73 3 4
5 13 53.96 42 14.10 378 224 3.07 / 1104.95 3 5
6 8 0.00 150 14.26 290 620 3.69 / 1105.58 3 15
Average= 5.19 (KJ/cycle)

Cycle 211 GMT 27/ 5/2022 2:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 29 14.19 434 179 0.18 / 1096.38 3 3
2 12 1096.84 3 10.59 1786 57 0.24 / 1096.44 3 3
3 12 1993.64 120 8.04 3008 2902 3.14 / 1099.34 3 3
4 7 1985.64 24 10.83 3032 788 3.93 / 1100.13 3 3
5 13 916.04 42 13.04 1601 877 4.80 / 1101.01 3 5
6 13 52.52 42 14.14 385 229 5.03 / 1101.24 3 5
7 8 0.08 150 14.31 302 648 5.68 / 1101.88 3 11
Average= 5.20 (KJ/cycle)

Cycle 210 GMT 25/ 5/2022 23:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 28 14.19 436 173 0.17 / 1091.29 3 3
2 12 1136.48 120 5.59 1698 1139 1.31 / 1092.43 3 3
3 7 1142.16 24 10.53 1854 469 1.78 / 1092.89 3 3
4 13 1222.72 42 11.42 1962 941 2.72 / 1093.84 3 3
5 13 1110.48 42 12.10 1850 940 3.66 / 1094.78 3 3
6 13 512.48 42 13.45 1042 589 4.25 / 1095.36 3 4
7 13 26.56 42 14.15 340 202 4.45 / 1095.57 3 5
8 8 -0.20 150 14.28 298 638 5.09 / 1096.20 3 9
Average= 5.20 (KJ/cycle)

Cycle 209 GMT 16/ 5/2022 5:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 28 14.17 446 177 0.18 / 1086.74 3 3
2 12 1141.44 120 5.80 1749 1217 1.39 / 1087.96 3 3
3 7 1145.80 24 10.57 1860 472 1.87 / 1088.43 3 3
4 13 1154.64 42 11.59 1871 911 2.78 / 1089.34 3 3
5 13 1027.24 42 12.24 1730 889 3.67 / 1090.23 3 3
6 13 99.16 42 14.00 448 263 3.93 / 1090.49 3 4
7 8 0.00 150 14.27 291 623 4.55 / 1091.11 3 6
Average= 5.20 (KJ/cycle)

Cycle 208 GMT 6/ 5/2022 11: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 29 14.20 439 181 0.18 / 1083.05 3 3
2 12 1129.92 120 7.36 1767 1561 1.74 / 1084.61 3 3
3 7 1123.84 24 10.93 1833 481 2.22 / 1085.09 3 3
4 13 593.88 42 13.16 1150 636 2.86 / 1085.72 3 3
5 13 54.40 42 14.10 372 220 3.08 / 1085.94 3 4
6 8 -0.08 150 14.26 289 618 3.70 / 1086.56 3 8
Average= 5.20 (KJ/cycle)

Cycle 207 GMT 26/ 4/2022 17: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 29 14.18 437 180 0.18 / 1077.43 3 3
2 12 1098.24 3 10.54 1794 57 0.24 / 1077.49 3 3
3 12 1996.04 120 7.88 2993 2830 3.07 / 1080.32 3 3
4 7 1988.48 24 10.81 3048 791 3.86 / 1081.11 3 3
5 13 933.80 42 13.02 1626 889 4.75 / 1082.00 3 4
6 13 65.64 42 14.14 396 235 4.98 / 1082.23 3 4
7 8 -0.12 150 14.33 295 634 5.62 / 1082.87 3 11
Average= 5.21 (KJ/cycle)

Cycle 206 GMT 25/ 4/2022 13:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 28 14.19 426 169 0.17 / 1072.78 3 3
2 12 1141.88 120 5.76 1764 1219 1.39 / 1074.00 3 3
3 7 1147.24 24 10.63 1864 476 1.86 / 1074.47 3 3
4 13 1188.44 42 11.66 1933 947 2.81 / 1075.42 3 3
5 13 1077.28 42 12.29 1803 931 3.74 / 1076.35 3 3
6 13 124.88 42 13.99 486 286 4.03 / 1076.63 3 4
7 8 0.00 150 14.28 287 615 4.64 / 1077.25 3 8
Average= 5.20 (KJ/cycle)

Cycle 205 GMT 15/ 4/2022 19:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 28 14.20 425 169 0.17 / 1068.37 3 3
2 12 1158.72 120 5.89 1782 1260 1.43 / 1069.63 3 3
3 7 1163.16 24 10.60 1879 478 1.91 / 1070.10 3 3
4 13 1140.48 42 11.78 1850 915 2.82 / 1071.02 3 3
5 13 757.36 42 12.98 1372 748 3.57 / 1071.77 3 4
6 13 54.80 42 14.09 380 225 3.79 / 1071.99 3 4
7 8 -0.12 150 14.29 287 615 4.41 / 1072.61 3 9
Average= 5.21 (KJ/cycle)

Cycle 204 GMT 6/ 4/2022 0:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 28 14.24 419 167 0.17 / 1064.53 3 3
2 12 1120.04 120 7.40 1762 1565 1.73 / 1066.09 3 3
3 7 1114.00 24 10.91 1846 483 2.22 / 1066.58 3 3
4 13 832.00 42 12.64 1464 777 2.99 / 1067.35 3 4
5 13 65.04 42 14.06 391 231 3.22 / 1067.58 3 4
6 8 -0.04 150 14.26 287 614 3.84 / 1068.20 3 8
Average= 5.21 (KJ/cycle)

Cycle 203 GMT 27/ 3/2022 6:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 28 14.19 426 169 0.17 / 1059.03 3 3
2 12 1103.80 3 10.60 1808 57 0.23 / 1059.09 3 3
3 12 2001.40 120 7.53 3001 2712 2.94 / 1061.80 3 3
4 7 1994.68 24 10.75 3036 783 3.72 / 1062.58 3 3
5 13 972.84 42 12.95 1666 906 4.63 / 1063.49 3 4
6 13 88.28 42 14.08 428 253 4.88 / 1063.74 3 4
7 8 0.00 150 14.33 289 621 5.50 / 1064.36 3 11
Average= 5.22 (KJ/cycle)

Cycle 202 GMT 26/ 3/2022 3:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 28 14.16 427 169 0.17 / 1054.84 3 3
2 12 1129.16 120 6.12 1753 1287 1.46 / 1056.13 3 3
3 7 1130.92 24 10.70 1836 471 1.93 / 1056.60 3 3
4 13 1045.36 42 12.00 1743 878 2.81 / 1057.48 3 3
5 13 476.44 42 13.41 984 554 3.36 / 1058.03 3 4
6 13 51.04 42 14.11 367 217 3.58 / 1058.25 3 5
7 8 0.00 150 14.28 283 606 4.18 / 1058.86 3 11
Average= 5.22 (KJ/cycle)

Cycle 201 GMT 16/ 3/2022 9:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 28 14.15 424 168 0.17 / 1050.86 3 3
2 12 1150.20 120 6.28 1786 1346 1.51 / 1052.21 3 3
3 7 1149.40 24 10.65 1862 476 1.99 / 1052.68 3 3
4 13 1034.80 42 11.98 1732 871 2.86 / 1053.55 3 3
5 13 172.08 42 13.86 547 318 3.18 / 1053.87 3 4
6 13 33.16 42 14.15 334 198 3.38 / 1054.07 3 5
7 8 -0.12 150 14.27 282 604 3.98 / 1054.67 3 11
Average= 5.22 (KJ/cycle)

Cycle 200 GMT 6/ 3/2022 15:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 29 14.28 420 174 0.17 / 1047.20 3 3
2 12 1114.96 120 7.54 1753 1586 1.76 / 1048.79 3 3
3 7 1108.84 24 10.94 1833 481 2.24 / 1049.27 3 3
4 13 546.32 42 13.17 1079 597 2.84 / 1049.87 3 4
5 13 43.32 42 14.10 354 210 3.05 / 1050.08 3 4
6 8 -0.08 150 14.25 288 616 3.66 / 1050.69 3 9
Average= 5.23 (KJ/cycle)

Cycle 199 GMT 24/ 2/2022 21:40: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 28 14.15 425 168 0.17 / 1041.54 3 3
2 12 1128.96 3 10.52 1830 58 0.23 / 1041.59 3 3
3 12 1992.84 120 7.27 2989 2608 2.83 / 1044.20 3 3
4 7 1984.72 24 10.76 3036 784 3.62 / 1044.99 3 3
5 13 1365.04 42 12.43 2217 1157 4.78 / 1046.14 3 3
6 13 124.08 42 14.02 479 282 5.06 / 1046.43 3 5
7 8 0.00 150 14.35 280 603 5.66 / 1047.03 3 10
Average= 5.24 (KJ/cycle)

Cycle 198 GMT 23/ 2/2022 18:40: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 28 14.14 438 173 0.17 / 1037.78 3 3
2 12 1127.68 120 6.41 1762 1355 1.53 / 1039.13 3 3
3 7 1125.52 24 10.81 1836 476 2.01 / 1039.61 3 3
4 13 1014.36 42 12.13 1718 875 2.88 / 1040.48 3 3
5 13 124.72 42 13.93 482 282 3.16 / 1040.77 3 4
6 8 0.00 150 14.27 282 604 3.77 / 1041.37 3 6
Average= 5.23 (KJ/cycle)

Cycle 197 GMT 14/ 2/2022 0:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 28 14.17 421 167 0.17 / 1033.95 3 3
2 12 1133.44 120 6.77 1777 1444 1.61 / 1035.39 3 3
3 7 1128.60 24 10.78 1870 484 2.09 / 1035.87 3 3
4 13 992.52 42 12.15 1689 862 2.96 / 1036.74 3 3
5 13 86.68 42 13.99 423 249 3.20 / 1036.99 3 4
6 8 -0.08 150 14.25 289 618 3.82 / 1037.60 3 9
Average= 5.24 (KJ/cycle)

Cycle 196 GMT 4/ 2/2022 6:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 28 14.23 432 172 0.17 / 1030.21 3 3
2 12 1131.40 120 7.90 1784 1691 1.86 / 1031.90 3 3
3 7 1124.56 24 11.06 1857 493 2.36 / 1032.40 3 3
4 13 515.36 42 13.24 1041 579 2.94 / 1032.97 3 4
5 13 36.04 42 14.13 339 201 3.14 / 1033.18 3 4
6 8 0.00 150 14.28 282 604 3.74 / 1033.78 3 10
Average= 5.25 (KJ/cycle)

Cycle 195 GMT 25/ 1/2022 12:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 28 14.17 435 173 0.17 / 1024.65 3 3
2 12 1118.96 3 10.77 1824 59 0.23 / 1024.71 3 3
3 12 1997.08 120 7.70 3000 2772 3.00 / 1027.48 3 3
4 7 1989.52 24 10.76 3061 790 3.79 / 1028.27 3 3
5 13 957.92 42 12.94 1656 900 4.69 / 1029.17 3 4
6 13 83.92 42 14.12 419 248 4.94 / 1029.42 3 4
7 8 0.04 150 14.36 287 618 5.56 / 1030.04 3 7
Average= 5.26 (KJ/cycle)

Cycle 194 GMT 24/ 1/2022 9:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 28 14.21 424 169 0.17 / 1020.76 3 3
2 12 1132.84 120 6.98 1772 1484 1.65 / 1022.25 3 3
3 7 1128.84 24 11.09 1833 488 2.14 / 1022.73 3 3
4 13 995.76 42 12.38 1698 883 3.02 / 1023.62 3 3
5 13 83.72 42 14.04 422 249 3.27 / 1023.87 3 4
6 8 -0.16 150 14.30 286 613 3.89 / 1024.48 3 7
Average= 5.25 (KJ/cycle)

Cycle 193 GMT 14/ 1/2022 15:50: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 28 14.19 422 168 0.17 / 1017.03 3 3
2 12 1152.20 82 7.25 1814 1078 1.25 / 1018.11 3 3
3 7 1151.60 24 11.03 1871 495 1.74 / 1018.61 3 3
4 13 1042.96 42 12.08 1748 887 2.63 / 1019.49 3 3
5 13 147.32 42 13.89 513 299 2.93 / 1019.79 3 4
6 13 29.48 42 14.17 327 195 3.12 / 1019.99 3 4
7 8 -0.20 150 14.29 283 607 3.73 / 1020.59 3 11
Average= 5.26 (KJ/cycle)

Cycle 192 GMT 4/ 1/2022 21:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 28 14.29 432 173 0.17 / 1013.53 3 3
2 12 1134.28 82 8.76 1801 1294 1.47 / 1014.82 3 3
3 7 1129.36 24 11.35 1840 501 1.97 / 1015.33 3 3
4 13 720.00 42 12.95 1314 715 2.68 / 1016.04 3 3
5 13 58.68 42 14.12 375 222 2.90 / 1016.26 3 4
6 8 0.04 150 14.32 280 601 3.51 / 1016.86 3 9
Average= 5.27 (KJ/cycle)

Cycle 191 GMT 26/12/2021 3:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 23 14.25 428 140 0.14 / 1008.04 3 3
2 10 1058.80 5 12.48 1789 112 0.25 / 1008.15 3 3
3 3 1056.48 1 11.57 1768 20 0.27 / 1008.17 3 3
4 3 1044.60 1 11.26 1738 20 0.29 / 1008.19 3 3
5 12 1124.32 5 11.51 1851 107 0.40 / 1008.30 3 3
6 12 1953.44 82 9.57 2985 2342 2.74 / 1010.64 3 3
7 7 1944.84 24 10.94 2992 786 3.53 / 1011.43 3 3
8 13 1101.36 42 12.87 1865 1008 4.53 / 1012.43 3 5
9 13 110.84 42 14.10 467 277 4.81 / 1012.71 3 5
10 8 0.04 150 14.38 300 647 5.46 / 1013.36 3 7
Average= 5.28 (KJ/cycle)

Cycle 190 GMT 24/12/2021 23:58: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 28 14.24 436 174 0.17 / 999.22 3 3
2 12 1115.04 9 8.02 1780 128 0.30 / 999.35 3 3
3 12 1985.16 200 5.85 2867 3354 3.66 / 1002.71 3 3
4 12 1982.72 82 7.13 2978 1741 5.40 / 1004.45 3 3
5 7 1977.16 24 10.69 3003 770 6.17 / 1005.22 3 3
6 13 1549.92 42 12.22 2460 1263 7.43 / 1006.48 3 3
7 13 460.60 42 13.59 982 561 7.99 / 1007.04 3 5
8 13 42.88 42 14.22 364 217 8.21 / 1007.26 3 5
9 8 -0.08 150 14.38 297 641 8.85 / 1007.90 3 6
Average= 5.28 (KJ/cycle)

Cycle 189 GMT 14/12/2021 22:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 28 14.25 429 171 0.17 / 990.86 3 3
2 12 1114.48 9 7.94 1759 126 0.30 / 990.98 3 3
3 12 1961.32 200 5.96 2837 3382 3.68 / 994.36 3 3
4 12 1954.20 82 7.32 2920 1753 5.43 / 996.12 3 3
5 7 1946.68 24 10.75 2955 762 6.19 / 996.88 3 3
6 13 1352.92 42 12.46 2203 1153 7.35 / 998.03 3 3
7 13 222.32 42 13.87 645 376 7.72 / 998.41 3 5
8 8 -0.08 150 14.36 299 644 8.37 / 999.05 3 10
Average= 5.26 (KJ/cycle)

Cycle 188 GMT 4/12/2021 21:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 28 14.26 442 176 0.18 / 982.69 3 3
2 12 1128.92 9 8.08 1800 131 0.31 / 982.82 3 3
3 12 1953.12 200 5.98 2847 3405 3.71 / 986.23 3 3
4 12 1949.48 82 7.38 2923 1769 5.48 / 988.00 3 3
5 7 1942.44 24 10.75 3012 777 6.26 / 988.77 3 3
6 13 1078.20 42 12.79 1834 985 7.24 / 989.76 3 4
7 13 129.48 42 14.00 506 298 7.54 / 990.06 3 5
8 8 -0.08 150 14.37 291 627 8.17 / 990.68 3 11
Average= 5.24 (KJ/cycle)

Cycle 187 GMT 24/11/2021 20:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 28 14.29 434 174 0.17 / 974.29 3 3
2 12 1129.44 9 7.89 1789 127 0.30 / 974.41 3 3
3 12 1980.72 200 5.98 2847 3405 3.71 / 977.82 3 3
4 12 1972.96 82 7.31 2952 1769 5.48 / 979.59 3 3
5 7 1965.52 24 10.79 2998 776 6.25 / 980.36 3 3
6 13 1094.28 50 12.69 1853 1176 7.43 / 981.54 3 4
7 13 116.96 50 14.02 486 341 7.77 / 981.88 3 5
8 8 -0.20 150 14.36 295 635 8.40 / 982.52 3 11
Average= 5.23 (KJ/cycle)

Cycle 186 GMT 14/11/2021 19:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 28 14.27 438 175 0.18 / 965.78 3 3
2 12 1133.64 9 7.95 1801 129 0.30 / 965.91 3 3
3 12 1979.56 200 6.04 2885 3485 3.79 / 969.39 3 3
4 12 1975.00 82 7.44 2959 1805 5.59 / 971.20 3 3
5 7 1968.28 24 10.81 3025 785 6.38 / 971.98 3 3
6 13 1112.60 50 12.69 1886 1197 7.58 / 973.18 2 4
7 13 71.60 50 14.13 415 293 7.87 / 973.47 3 5
8 8 0.00 150 14.37 298 642 8.51 / 974.11 3 10
Average= 5.21 (KJ/cycle)

Cycle 185 GMT 4/11/2021 18:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 28 14.30 440 176 0.18 / 957.28 3 3
2 12 1120.36 9 8.08 1773 129 0.31 / 957.41 3 3
3 12 1962.44 200 6.02 2860 3443 3.75 / 960.86 3 3
4 12 1956.92 82 7.34 2924 1760 5.51 / 962.62 3 3
5 7 1949.40 24 10.85 3013 785 6.29 / 963.40 3 3
6 13 1195.08 50 12.65 1992 1260 7.55 / 964.66 3 4
7 13 89.16 50 14.11 435 307 7.86 / 964.97 3 5
8 8 -0.16 150 14.38 294 634 8.49 / 965.60 3 9
Average= 5.19 (KJ/cycle)

Cycle 184 GMT 25/10/2021 17:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 28 14.30 432 173 0.17 / 949.21 3 3
2 12 1109.92 10 8.09 1778 144 0.32 / 949.35 3 3
3 12 1958.84 120 5.85 2767 1942 2.26 / 951.29 3 3
4 12 1957.24 82 6.44 2960 1563 3.82 / 952.86 3 3
5 7 1953.00 24 10.75 2993 772 4.59 / 953.63 3 3
6 13 1837.80 50 11.70 2849 1667 6.26 / 955.30 3 3
7 13 760.28 50 13.23 1390 919 7.18 / 956.22 3 5
8 13 42.96 50 14.26 359 256 7.44 / 956.47 3 4
9 8 0.00 150 14.41 294 635 8.07 / 957.11 3 10
Average= 5.17 (KJ/cycle)

Cycle 183 GMT 15/10/2021 16:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 28 14.26 448 179 0.18 / 940.93 3 3
2 12 1112.20 10 8.01 1768 142 0.32 / 941.07 3 3
3 12 1953.28 120 5.86 2805 1972 2.29 / 943.05 3 3
4 12 1952.44 82 6.36 3008 1569 3.86 / 944.61 3 3
5 7 1948.36 24 10.80 2965 769 4.63 / 945.38 3 3
6 13 1828.20 50 11.72 2845 1667 6.30 / 947.05 3 3
7 13 899.28 50 13.05 1595 1041 7.34 / 948.09 3 4
8 13 77.44 50 14.16 423 299 7.64 / 948.39 3 5
9 8 -0.16 150 14.38 299 645 8.28 / 949.03 3 5
Average= 5.16 (KJ/cycle)

Cycle 182 GMT 5/10/2021 15:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 28 14.25 437 174 0.17 / 932.76 3 3
2 12 1138.04 10 7.86 1805 142 0.32 / 932.91 3 3
3 12 1972.88 120 5.85 2758 1936 2.25 / 934.84 3 3
4 12 1973.88 82 6.32 3010 1560 3.81 / 936.40 3 3
5 7 1971.04 24 10.83 3008 782 4.59 / 937.18 3 3
6 13 1861.32 50 11.70 2876 1682 6.28 / 938.87 3 3
7 13 793.60 50 13.17 1453 957 7.23 / 939.82 3 5
8 13 62.52 50 14.20 397 282 7.52 / 940.10 3 5
9 8 -0.08 150 14.39 300 648 8.16 / 940.75 3 7
Average= 5.14 (KJ/cycle)

Cycle 181 GMT 25/ 9/2021 14:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 28 14.31 423 169 0.17 / 924.89 3 3
2 12 1123.80 10 7.79 1770 138 0.31 / 925.02 3 3
3 12 1954.40 120 5.85 2780 1952 2.26 / 926.98 3 3
4 12 1956.12 82 6.56 2937 1580 3.84 / 928.56 3 3
5 7 1952.00 24 10.85 2978 775 4.61 / 929.33 3 3
6 13 1843.28 50 11.75 2858 1679 6.29 / 931.01 3 3
7 13 457.20 50 13.57 984 668 6.96 / 931.68 3 5
8 13 46.08 50 14.24 369 263 7.22 / 931.94 3 5
9 8 -0.08 150 14.38 301 649 7.87 / 932.59 3 12
Average= 5.12 (KJ/cycle)

Cycle 180 GMT 15/ 9/2021 13:26:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 28 14.31 451 181 0.18 / 916.73 3 3
2 12 1128.76 10 7.67 1779 136 0.32 / 916.87 3 3
3 12 1969.08 120 5.85 2747 1928 2.25 / 918.80 3 3
4 12 1969.08 82 6.40 2997 1573 3.82 / 920.37 3 3
5 7 1965.36 24 10.89 3002 785 4.60 / 921.15 3 3
6 13 1843.60 50 11.77 2847 1675 6.28 / 922.83 3 3
7 13 825.04 50 13.16 1487 978 7.26 / 923.81 3 5
8 13 51.68 50 14.25 375 267 7.52 / 924.08 3 5
9 8 -0.04 150 14.40 297 642 8.17 / 924.72 3 10
Average= 5.11 (KJ/cycle)

Cycle 179 GMT 5/ 9/2021 12:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 28 14.30 429 172 0.17 / 909.12 3 3
2 12 1127.48 10 8.06 1797 145 0.32 / 909.26 3 3
3 12 1942.04 120 5.87 2819 1986 2.30 / 911.25 3 3
4 12 1940.12 82 6.67 2912 1593 3.90 / 912.84 3 3
5 7 1934.52 24 10.94 2962 778 4.67 / 913.62 3 3
6 13 1813.12 50 11.80 2820 1664 6.34 / 915.28 3 3
7 13 414.60 50 13.63 918 626 6.96 / 915.91 3 5
8 8 0.04 150 14.39 297 641 7.60 / 916.55 3 11
Average= 5.09 (KJ/cycle)

Cycle 178 GMT 26/ 8/2021 11:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 28 14.31 441 177 0.18 / 901.53 3 3
2 12 1146.60 11 8.11 1821 162 0.34 / 901.70 3 3
3 12 1947.28 120 5.87 2838 1999 2.34 / 903.70 3 3
4 12 1944.88 50 6.29 3005 945 3.28 / 904.64 3 3
5 7 1941.52 24 10.91 2977 779 4.06 / 905.42 3 3
6 13 1819.08 50 11.81 2818 1664 5.73 / 907.08 3 3
7 13 777.24 50 13.22 1414 935 6.66 / 908.02 3 4
8 13 54.12 50 14.20 390 277 6.94 / 908.30 3 5
9 8 -0.08 150 14.38 302 651 7.59 / 908.95 3 13
Average= 5.08 (KJ/cycle)

Cycle 177 GMT 16/ 8/2021 10:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 27 14.31 437 169 0.17 / 893.88 3 3
2 12 1138.24 11 8.26 1813 165 0.33 / 894.04 3 3
3 12 1947.84 120 5.88 2883 2034 2.37 / 896.08 3 3
4 12 1948.08 50 6.29 3001 944 3.31 / 897.02 3 3
5 7 1945.80 24 10.90 2981 780 4.09 / 897.80 3 3
6 13 1846.28 50 11.75 2857 1678 5.77 / 899.48 3 3
7 13 802.80 50 13.19 1454 959 6.73 / 900.44 3 4
8 13 56.08 50 14.22 389 277 7.01 / 900.71 3 6
9 8 -0.08 150 14.39 298 643 7.65 / 901.36 3 9
Average= 5.06 (KJ/cycle)

Cycle 176 GMT 6/ 8/2021 9:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 27 14.31 434 168 0.17 / 886.30 3 3
2 12 1118.68 11 8.11 1789 160 0.33 / 886.46 3 3
3 12 1941.84 120 5.84 2736 1917 2.24 / 888.38 3 3
4 12 1939.80 50 5.82 2977 866 3.11 / 889.24 3 3
5 7 1939.12 24 10.90 2971 777 3.89 / 890.02 3 3
6 13 1835.84 50 11.78 2821 1662 5.55 / 891.68 3 3
7 13 976.84 50 13.01 1693 1101 6.65 / 892.78 3 5
8 13 58.96 50 14.20 395 280 6.93 / 893.06 3 5
9 8 -0.08 150 14.39 300 648 7.58 / 893.71 3 11
Average= 5.05 (KJ/cycle)

Cycle 175 GMT 27/ 7/2021 8:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 27 14.30 436 168 0.17 / 878.55 3 3
2 12 1130.80 11 7.55 1786 148 0.32 / 878.70 3 3
3 12 1960.76 120 5.83 2623 1835 2.15 / 880.53 2 3
4 12 1959.44 50 5.82 2962 862 3.01 / 881.40 3 3
5 7 1959.04 24 10.83 3013 783 3.80 / 882.18 3 3
6 13 1868.16 50 11.65 2872 1673 5.47 / 883.85 3 3
7 13 1291.32 50 12.64 2131 1347 6.82 / 885.20 3 4
8 13 55.72 50 14.20 390 277 7.09 / 885.48 3 6
9 8 -0.12 150 14.37 304 655 7.75 / 886.13 3 8
Average= 5.03 (KJ/cycle)

Cycle 174 GMT 17/ 7/2021 7:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 27 14.32 432 167 0.17 / 872.00 3 3
2 12 1125.48 11 8.11 1780 159 0.33 / 872.16 3 3
3 12 1924.68 120 6.27 2843 2139 2.46 / 874.30 3 3
4 12 1917.24 50 6.77 2871 972 3.44 / 875.27 3 3
5 7 1909.96 24 11.02 2966 784 4.22 / 876.05 3 3
6 13 1329.52 50 12.52 2182 1366 5.59 / 877.42 3 3
7 13 77.80 50 14.13 429 303 5.89 / 877.72 3 6
8 8 -0.04 150 14.35 306 659 6.55 / 878.38 3 10
Average= 5.02 (KJ/cycle)

Cycle 173 GMT 7/ 7/2021 6:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 27 14.33 437 169 0.17 / 864.35 3 3
2 12 1102.92 11 8.01 1751 154 0.32 / 864.50 3 3
3 12 1947.04 120 5.86 2765 1944 2.27 / 866.44 3 3
4 12 1946.88 50 5.91 3006 888 3.16 / 867.33 3 3
5 7 1945.96 24 11.05 2992 793 3.95 / 868.13 3 3
6 13 1851.32 50 11.88 2848 1692 5.64 / 869.82 3 3
7 13 960.20 50 13.05 1668 1088 6.73 / 870.91 3 4
8 13 52.40 50 14.23 387 275 7.00 / 871.18 3 6
9 8 -0.20 150 14.39 302 652 7.66 / 871.83 3 8
Average= 5.01 (KJ/cycle)

Cycle 172 GMT 27/ 6/2021 5:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 27 14.31 431 167 0.17 / 857.07 3 3
2 12 1126.12 12 7.51 1778 160 0.33 / 857.23 3 3
3 12 1950.04 95 5.84 2600 1442 1.77 / 858.67 3 3
4 12 1950.08 50 5.85 2893 846 2.62 / 859.52 3 3
5 7 1950.12 24 10.94 2989 785 3.40 / 860.31 3 3
6 13 1860.12 50 11.81 2864 1691 5.09 / 862.00 3 3
7 13 1147.88 50 12.84 1934 1242 6.33 / 863.24 3 4
8 13 62.20 50 14.21 402 286 6.62 / 863.52 3 5
9 8 0.00 150 14.39 302 652 7.27 / 864.18 3 9
Average= 5.00 (KJ/cycle)

Cycle 171 GMT 17/ 6/2021 4:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 27 14.33 437 169 0.17 / 850.41 3 3
2 12 1135.96 12 8.17 1801 177 0.35 / 850.59 3 3
3 12 1933.40 95 5.95 2861 1617 1.96 / 852.21 3 3
4 12 1931.60 50 6.91 2875 993 2.96 / 853.20 3 3
5 7 1926.52 24 11.09 2940 783 3.74 / 853.98 3 3
6 13 1797.68 50 11.94 2785 1663 5.40 / 855.65 3 3
7 13 378.00 50 13.72 872 598 6.00 / 856.24 3 5
8 8 0.00 150 14.36 307 661 6.66 / 856.91 3 11
Average= 4.98 (KJ/cycle)

Cycle 170 GMT 7/ 6/2021 3:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 27 14.33 433 168 0.17 / 842.74 3 3
2 12 1144.04 12 8.33 1810 181 0.35 / 842.92 3 3
3 12 1989.60 95 5.91 2887 1621 1.97 / 844.54 3 3
4 12 1988.68 50 6.26 3035 950 2.92 / 845.49 3 3
5 7 1985.44 24 11.10 3027 806 3.73 / 846.30 3 3
6 13 1877.12 50 11.87 2888 1714 5.44 / 848.01 3 3
7 13 1271.56 50 12.74 2097 1336 6.78 / 849.35 3 4
8 13 25.24 50 14.31 346 248 7.02 / 849.60 3 5
9 8 0.04 150 14.42 300 649 7.67 / 850.24 3 12
Average= 4.97 (KJ/cycle)

Cycle 169 GMT 28/ 5/2021 2:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 27 14.33 446 173 0.17 / 835.47 3 3
2 12 1124.96 12 8.04 1785 172 0.34 / 835.64 3 3
3 12 1937.60 95 5.88 2756 1540 1.88 / 837.18 2 3
4 12 1937.72 50 6.06 2951 894 2.78 / 838.08 3 3
5 7 1935.96 24 11.07 2953 785 3.56 / 838.86 3 3
6 13 1841.92 50 11.97 2837 1698 5.26 / 840.56 3 3
7 13 970.80 50 13.07 1688 1103 6.36 / 841.66 3 6
8 13 25.32 50 14.29 350 250 6.61 / 841.91 3 6
9 8 0.00 150 14.40 305 659 7.27 / 842.57 3 14
Average= 4.96 (KJ/cycle)

Cycle 168 GMT 18/ 5/2021 1:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 27 14.33 438 169 0.17 / 827.83 3 3
2 12 1134.92 12 7.63 1797 165 0.33 / 828.00 3 3
3 12 2009.68 95 5.86 2664 1483 1.82 / 829.48 2 3
4 12 2012.88 50 5.85 2972 869 2.69 / 830.35 3 3
5 7 2014.20 24 11.00 3064 809 3.50 / 831.16 3 3
6 13 1936.64 50 11.79 2938 1732 5.23 / 832.89 3 3
7 13 1493.48 50 12.55 2366 1485 6.71 / 834.38 3 4
8 13 48.32 50 14.27 375 268 6.98 / 834.64 3 5
9 8 0.04 150 14.41 303 655 7.63 / 835.30 3 8
Average= 4.94 (KJ/cycle)

Cycle 167 GMT 8/ 5/2021 1:11: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 27 14.38 428 166 0.17 / 821.35 3 3
2 12 1118.52 12 8.31 1773 177 0.34 / 821.53 3 3
3 12 2001.24 95 6.47 2924 1797 2.14 / 823.33 2 3
4 12 1996.48 50 7.23 2959 1070 3.21 / 824.40 3 3
5 7 1990.12 24 11.20 3020 812 4.02 / 825.21 3 3
6 13 1439.48 50 12.50 2323 1452 5.47 / 826.66 3 3
7 13 124.16 50 14.11 495 349 5.82 / 827.01 3 6
8 8 -0.04 150 14.37 305 657 6.48 / 827.67 3 11
Average= 4.93 (KJ/cycle)

Cycle 166 GMT 28/ 4/2021 0:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 27 14.38 430 167 0.17 / 813.55 3 3
2 12 1118.32 12 7.98 1782 171 0.34 / 813.72 3 3
3 12 2003.56 95 5.90 2892 1621 1.96 / 815.34 3 3
4 12 2006.40 50 6.23 3130 975 2.93 / 816.32 3 3
5 7 2005.24 24 11.30 3048 827 3.76 / 817.14 3 3
6 13 1903.32 50 12.05 2916 1757 5.52 / 818.90 3 3
7 13 1274.24 50 12.79 2102 1344 6.86 / 820.25 3 4
8 13 44.48 50 14.28 378 270 7.13 / 820.52 3 6
9 8 -0.08 150 14.41 310 670 7.80 / 821.19 3 11
Average= 4.92 (KJ/cycle)

Cycle 165 GMT 18/ 4/2021 0:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 27 14.36 443 172 0.17 / 806.84 3 3
2 12 1129.68 10 8.14 1789 146 0.32 / 806.98 3 3
3 12 2006.68 105 6.21 2949 1923 2.24 / 808.91 3 3
4 7 2005.40 24 11.02 3053 807 3.05 / 809.71 3 3
5 13 1901.76 50 11.97 2920 1748 4.80 / 811.46 3 3
6 13 854.72 50 13.22 1520 1005 5.80 / 812.47 3 5
7 13 39.80 50 14.29 368 263 6.06 / 812.73 3 6
8 8 -0.12 150 14.40 303 654 6.72 / 813.38 3 12
Average= 4.90 (KJ/cycle)

Cycle 164 GMT 8/ 4/2021 0: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 27 14.36 430 167 0.17 / 799.95 3 3
2 12 1122.52 10 7.42 1782 132 0.30 / 800.08 3 3
3 12 2006.48 105 5.90 2891 1791 2.09 / 801.87 3 3
4 7 2007.88 24 11.02 3060 809 2.90 / 802.68 3 3
5 13 1928.48 50 11.97 2960 1772 4.67 / 804.45 3 3
6 13 1207.04 50 12.84 2007 1288 5.96 / 805.74 3 5
7 13 51.44 50 14.27 392 280 6.24 / 806.02 3 6
8 8 -0.04 150 14.42 299 647 6.89 / 806.67 3 12
Average= 4.89 (KJ/cycle)

Cycle 163 GMT 29/ 3/2021 0:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 27 14.37 425 165 0.16 / 793.20 3 3
2 12 1111.52 10 6.02 2083 125 0.29 / 793.33 3 3
3 12 2006.96 95 5.89 2882 1613 1.90 / 794.94 3 3
4 7 2008.52 24 11.01 3062 809 2.71 / 795.75 3 3
5 13 1933.28 50 11.97 2949 1765 4.48 / 797.51 3 3
6 13 1214.68 50 12.84 2019 1296 5.77 / 798.81 3 4
7 13 85.24 50 14.20 441 313 6.09 / 799.12 3 6
8 8 -0.04 150 14.40 304 657 6.74 / 799.78 3 12
Average= 4.88 (KJ/cycle)

Cycle 162 GMT 19/ 3/2021 0:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 27 14.37 440 171 0.17 / 786.62 3 3
2 12 1117.44 10 7.94 1755 139 0.31 / 786.76 3 3
3 12 2004.00 95 6.42 2988 1822 2.13 / 788.58 3 3
4 7 2002.04 24 11.09 3049 812 2.94 / 789.40 3 3
5 13 1883.96 50 12.05 2896 1745 4.69 / 791.14 3 3
6 13 826.12 50 13.28 1471 977 5.67 / 792.12 3 4
7 13 45.88 50 14.28 377 269 5.93 / 792.39 3 5
8 8 -0.04 150 14.41 301 651 6.59 / 793.04 3 11
Average= 4.87 (KJ/cycle)

Cycle 161 GMT 9/ 3/2021 0:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 27 14.38 447 174 0.17 / 779.85 3 3
2 12 1149.48 10 7.35 1807 133 0.31 / 779.98 3 3
3 12 2010.08 95 6.18 2990 1755 2.06 / 781.74 3 3
4 7 2009.96 24 11.14 3059 818 2.88 / 782.55 3 3
5 13 1923.36 50 12.03 2931 1763 4.64 / 784.32 3 3
6 13 1051.76 50 13.02 1791 1166 5.81 / 785.48 3 4
7 13 88.12 50 14.21 445 316 6.12 / 785.80 3 6
8 8 -0.04 150 14.41 302 653 6.78 / 786.45 3 14
Average= 4.85 (KJ/cycle)

Cycle 160 GMT 27/ 2/2021 0:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 27 14.36 447 173 0.17 / 773.10 3 3
2 12 1120.80 10 5.82 2103 122 0.30 / 773.22 3 3
3 12 2006.04 95 5.94 2970 1676 1.97 / 774.90 3 3
4 7 2006.96 24 11.14 3067 820 2.79 / 775.72 3 3
5 13 1922.44 50 12.00 2927 1756 4.55 / 777.48 3 3
6 13 1194.16 50 12.87 1984 1277 5.82 / 778.75 3 4
7 13 43.32 50 14.28 376 268 6.09 / 779.02 3 5
8 8 0.12 150 14.41 302 653 6.75 / 779.67 3 10
Average= 4.84 (KJ/cycle)

Cycle 159 GMT 17/ 2/2021 0:50: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 28 14.39 438 176 0.18 / 767.04 3 3
2 12 1113.68 10 7.44 1768 132 0.31 / 767.17 3 3
3 12 2000.20 95 6.79 2932 1891 2.20 / 769.06 3 3
4 7 1996.28 24 11.18 3035 814 3.01 / 769.88 3 3
5 13 1597.36 50 12.40 2524 1565 4.58 / 771.44 3 3
6 13 360.44 50 13.82 836 578 5.16 / 772.02 3 5
7 13 23.96 50 14.32 346 248 5.40 / 772.27 3 6
8 8 -0.20 150 14.38 306 660 6.06 / 772.93 3 12
Average= 4.83 (KJ/cycle)

Cycle 158 GMT 7/ 2/2021 1:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 28 14.38 449 181 0.18 / 760.59 3 3
2 12 1118.12 10 7.35 1773 130 0.31 / 760.72 3 3
3 12 2008.52 95 6.57 2954 1844 2.15 / 762.56 3 3
4 7 2006.44 24 11.21 3053 821 2.98 / 763.38 3 3
5 13 1879.00 50 12.11 2893 1752 4.73 / 765.14 3 3
6 13 622.08 50 13.53 1201 812 5.54 / 765.95 3 4
7 13 22.64 50 14.33 348 249 5.79 / 766.20 3 6
8 8 -0.08 150 14.40 309 667 6.46 / 766.87 3 10
Average= 4.82 (KJ/cycle)

Cycle 157 GMT 28/ 1/2021 1:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 28 14.40 436 176 0.18 / 754.15 3 3
2 12 1124.40 10 7.13 1764 126 0.30 / 754.27 3 3
3 12 2005.08 81 6.43 2940 1531 1.83 / 755.80 3 3
4 7 2003.20 24 11.22 3049 821 2.65 / 756.63 3 3
5 13 1888.96 50 12.08 2922 1765 4.42 / 758.39 3 3
6 13 952.24 50 13.15 1659 1091 5.51 / 759.48 3 6
7 13 43.68 50 14.30 373 267 5.78 / 759.75 3 6
8 8 -0.04 150 14.39 306 661 6.44 / 760.41 3 12
Average= 4.81 (KJ/cycle)

Cycle 156 GMT 18/ 1/2021 1:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 27 14.38 431 167 0.17 / 747.82 3 3
2 12 1123.92 10 7.49 1766 132 0.30 / 747.95 3 3
3 12 2002.60 81 6.93 2960 1662 1.96 / 749.61 3 3
4 7 1999.04 24 11.22 3032 816 2.78 / 750.43 3 3
5 13 1866.12 50 12.15 2816 1711 4.49 / 752.14 3 3
6 13 745.60 50 13.38 1363 912 5.40 / 753.05 3 5
7 13 33.84 50 14.32 363 260 5.66 / 753.31 3 6
8 8 -0.12 150 14.40 306 661 6.32 / 753.97 3 13
Average= 4.80 (KJ/cycle)

Cycle 155 GMT 8/ 1/2021 2:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 27 14.39 435 169 0.17 / 741.45 3 3
2 12 1122.76 10 6.98 1773 124 0.29 / 741.57 3 3
3 12 2009.88 81 6.76 2967 1625 1.92 / 743.19 3 3
4 7 2007.48 24 11.25 3050 823 2.74 / 744.02 3 3
5 13 1877.92 50 12.12 2896 1755 4.50 / 745.77 3 3
6 13 794.24 50 13.33 1434 956 5.45 / 746.73 3 5
7 13 43.76 50 14.32 373 267 5.72 / 747.00 3 6
8 8 0.00 150 14.40 303 654 6.37 / 747.65 3 12
Average= 4.79 (KJ/cycle)

Cycle 154 GMT 29/12/2020 2:34: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 28 14.42 434 175 0.18 / 735.17 3 3
2 12 1118.56 10 7.07 1746 123 0.30 / 735.30 3 3
3 12 2004.68 71 6.76 2939 1411 1.71 / 736.71 3 3
4 7 2002.44 24 11.20 3044 818 2.53 / 737.52 3 3
5 13 1889.64 50 12.06 2908 1754 4.28 / 739.28 3 3
6 13 942.48 50 13.16 1642 1080 5.36 / 740.36 3 5
7 13 44.00 50 14.32 373 267 5.63 / 740.63 3 5
8 8 -0.12 150 14.43 301 652 6.28 / 741.28 3 10
Average= 4.78 (KJ/cycle)

Cycle 153 GMT 19/12/2020 3: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 28 14.44 428 173 0.17 / 729.22 3 3
2 12 1108.72 10 7.29 1762 128 0.30 / 729.35 3 3
3 12 2001.32 71 6.97 2901 1436 1.74 / 730.78 3 3
4 7 1997.80 24 11.20 3029 814 2.55 / 731.60 3 3
5 13 1733.56 50 12.24 2712 1660 4.21 / 733.26 3 3
6 13 657.68 50 13.49 1238 835 5.05 / 734.09 3 5
7 13 47.60 50 14.32 373 267 5.31 / 734.36 3 5
8 8 -0.28 150 14.42 295 638 5.95 / 735.00 3 7
Average= 4.77 (KJ/cycle)

Cycle 152 GMT 9/12/2020 3:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 28 14.43 432 175 0.17 / 723.49 3 3
2 12 1127.92 10 6.94 1769 123 0.30 / 723.61 3 3
3 12 2005.20 64 7.07 2941 1331 1.63 / 724.94 3 3
4 7 2002.48 24 11.24 3045 821 2.45 / 725.76 3 3
5 13 1877.84 42 12.21 2888 1481 3.93 / 727.24 3 3
6 13 985.96 42 13.19 1692 937 4.87 / 728.18 3 4
7 13 71.96 42 14.30 401 241 5.11 / 728.42 3 5
8 8 -0.04 150 14.45 289 626 5.74 / 729.05 3 7
Average= 4.77 (KJ/cycle)

Cycle 151 GMT 29/11/2020 3:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 28 14.42 434 175 0.18 / 717.83 3 3
2 12 1125.64 10 7.27 1776 129 0.30 / 717.96 3 3
3 12 2001.40 64 7.14 2915 1332 1.64 / 719.30 3 3
4 7 1998.24 24 11.20 3038 817 2.45 / 720.11 3 3
5 13 1864.56 42 12.17 2879 1472 3.92 / 721.58 3 3
6 13 830.72 42 13.33 1487 833 4.76 / 722.42 3 4
7 13 80.12 42 14.27 427 256 5.01 / 722.67 3 5
8 8 -0.04 150 14.44 295 639 5.65 / 723.31 3 8
Average= 4.76 (KJ/cycle)

Cycle 150 GMT 19/11/2020 3:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 28 14.45 431 174 0.17 / 712.44 3 3
2 12 1107.04 10 7.98 1737 139 0.31 / 712.58 3 3
3 12 2000.12 58 7.50 2919 1270 1.58 / 713.85 3 3
4 7 1996.68 24 11.25 3024 816 2.40 / 714.66 3 3
5 13 1738.12 36 12.48 2715 1220 3.62 / 715.88 3 3
6 13 868.60 36 13.36 1527 734 4.35 / 716.62 3 4
7 13 110.24 36 14.22 469 240 4.59 / 716.86 3 5
8 13 24.28 36 14.41 329 171 4.76 / 717.03 3 4
9 8 -0.24 150 14.44 291 630 5.39 / 717.66 3 9
Average= 4.75 (KJ/cycle)

Cycle 149 GMT 9/11/2020 3: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 28 14.43 426 172 0.17 / 707.09 3 3
2 12 1125.44 9 7.88 1785 127 0.30 / 707.21 3 3
3 12 2008.20 58 7.64 2952 1308 1.61 / 708.52 3 3
4 7 2005.32 24 11.25 3040 821 2.43 / 709.34 3 3
5 13 1881.36 32 12.44 2901 1155 3.58 / 710.50 3 3
6 13 1011.24 32 13.27 1737 738 4.32 / 711.23 3 4
7 13 135.68 32 14.18 509 231 4.55 / 711.47 3 4
8 13 36.80 32 14.39 352 162 4.71 / 711.63 3 4
9 8 0.12 150 14.44 294 637 5.35 / 712.26 3 11
Average= 4.75 (KJ/cycle)

Cycle 148 GMT 30/10/2020 2:47: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 28 14.42 425 172 0.17 / 701.91 3 3
2 12 1124.36 9 7.93 1777 127 0.30 / 702.03 3 3
3 12 2004.64 58 7.87 2921 1333 1.63 / 703.37 3 3
4 7 2001.24 24 11.25 3047 823 2.45 / 704.19 3 3
5 13 1603.64 32 12.68 2549 1034 3.49 / 705.22 3 3
6 13 875.92 32 13.37 1556 666 4.15 / 705.89 3 4
7 13 113.32 32 14.19 488 222 4.38 / 706.11 3 5
8 13 24.60 32 14.38 340 156 4.53 / 706.27 3 5
9 8 -0.08 150 14.40 299 646 5.18 / 706.91 3 10
Average= 4.74 (KJ/cycle)

Cycle 147 GMT 20/10/2020 2:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 28 14.42 432 174 0.17 / 696.77 3 3
2 12 1119.00 9 8.14 1782 131 0.30 / 696.90 3 3
3 12 2001.40 58 8.24 2945 1407 1.71 / 698.31 3 3
4 7 1997.64 24 11.28 3029 820 2.53 / 699.13 3 3
5 13 1738.44 32 12.56 2740 1101 3.63 / 700.23 3 3
6 13 831.68 32 13.40 1491 639 4.27 / 700.87 3 6
7 13 91.28 32 14.22 454 207 4.48 / 701.08 3 5
8 8 -0.20 150 14.38 305 658 5.14 / 701.74 3 9
Average= 4.74 (KJ/cycle)

Cycle 146 GMT 10/10/2020 1:51:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 27 14.42 430 167 0.17 / 691.66 3 3
2 12 1121.64 9 8.42 1792 136 0.30 / 691.79 3 3
3 12 2001.88 46 8.34 2899 1112 1.42 / 692.91 3 3
4 7 1998.04 24 11.30 3034 823 2.24 / 693.73 3 3
5 13 1733.48 32 12.55 2720 1092 3.33 / 694.82 3 3
6 13 1002.08 32 13.24 1729 733 4.06 / 695.55 3 5
7 13 106.76 32 14.20 471 214 4.28 / 695.77 3 4
8 13 54.60 32 14.32 389 178 4.46 / 695.95 3 5
9 8 0.12 150 14.39 302 652 5.11 / 696.60 3 11
Average= 4.74 (KJ/cycle)

Cycle 145 GMT 30/ 9/2020 1:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 27 14.42 428 167 0.17 / 686.40 3 3
2 12 1123.68 9 8.66 1799 140 0.31 / 686.54 3 3
3 12 2007.72 46 8.58 2923 1154 1.46 / 687.69 3 3
4 7 2005.04 24 11.31 3044 826 2.29 / 688.52 3 3
5 13 1889.96 32 12.36 2930 1159 3.45 / 689.68 3 4
6 13 984.60 32 13.25 1711 725 4.17 / 690.40 3 4
7 13 196.92 32 14.07 610 275 4.45 / 690.68 3 5
8 13 34.68 32 14.34 360 165 4.61 / 690.84 3 5
9 8 -0.08 150 14.38 301 649 5.26 / 691.49 3 13
Average= 4.74 (KJ/cycle)

Cycle 144 GMT 20/ 9/2020 0:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 27 14.40 435 169 0.17 / 681.55 3 3
2 12 1134.24 9 9.17 1820 150 0.32 / 681.70 3 3
3 12 2000.64 46 8.89 2946 1205 1.52 / 682.90 3 3
4 7 1996.60 24 11.32 3037 825 2.35 / 683.73 3 3
5 13 1598.48 32 12.66 2553 1034 3.38 / 684.76 3 3
6 13 735.12 32 13.47 1365 588 3.97 / 685.35 3 5
7 13 122.80 32 14.16 502 227 4.20 / 685.58 3 5
8 8 -0.12 150 14.37 303 653 4.85 / 686.23 3 7
Average= 4.73 (KJ/cycle)

Cycle 143 GMT 9/ 9/2020 23:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 27 14.39 438 170 0.17 / 676.56 3 3
2 12 1119.88 6 8.13 1790 87 0.26 / 676.65 3 3
3 12 2007.64 46 8.94 2928 1204 1.46 / 677.86 3 3
4 7 2004.52 24 11.35 3045 829 2.29 / 678.69 3 3
5 13 1881.44 32 12.37 2922 1157 3.45 / 679.84 3 3
6 13 863.28 32 13.34 1540 657 4.11 / 680.50 3 5
7 13 126.04 32 14.16 506 229 4.33 / 680.73 3 5
8 8 -0.12 150 14.39 301 650 4.98 / 681.38 3 9
Average= 4.73 (KJ/cycle)

Cycle 142 GMT 30/ 8/2020 23:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 27 14.39 445 173 0.17 / 671.73 3 3
2 12 1112.40 6 8.73 1772 93 0.27 / 671.83 3 3
3 12 2002.56 46 9.30 2957 1265 1.53 / 673.09 2 3
4 7 1999.04 24 11.38 3034 829 2.36 / 673.92 3 3
5 13 1591.16 32 12.68 2533 1028 3.39 / 674.95 2 4
6 13 718.12 32 13.48 1332 575 3.96 / 675.52 3 4
7 13 117.52 32 14.18 490 222 4.18 / 675.74 3 5
8 8 0.04 150 14.39 301 650 4.83 / 676.39 3 9
Average= 4.73 (KJ/cycle)

Cycle 141 GMT 20/ 8/2020 23: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 27 14.40 438 170 0.17 / 666.63 3 3
2 12 1120.12 4 7.32 1758 51 0.22 / 666.68 3 3
3 12 2003.32 36 9.04 2920 950 1.17 / 667.63 3 3
4 7 2001.84 24 11.31 3036 824 2.00 / 668.45 3 3
5 13 1878.80 32 12.38 2894 1146 3.14 / 669.60 3 3
6 13 1130.84 32 13.12 1899 797 3.94 / 670.39 3 5
7 13 333.96 32 13.88 801 356 4.30 / 670.75 3 5
8 13 39.32 32 14.34 361 166 4.46 / 670.92 3 5
9 8 -0.08 150 14.37 299 644 5.11 / 671.56 3 8
Average= 4.73 (KJ/cycle)

Cycle 140 GMT 10/ 8/2020 23:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 27 14.40 448 174 0.17 / 661.56 3 3
2 12 1114.36 4 8.12 1783 58 0.23 / 661.62 3 3
3 12 2012.36 36 9.37 2912 982 1.21 / 662.60 3 3
4 7 2010.92 24 11.32 3043 827 2.04 / 663.42 3 3
5 13 1889.64 32 12.36 2917 1154 3.19 / 664.58 3 3
6 13 1124.92 32 13.12 1895 796 3.99 / 665.37 3 5
7 13 194.36 32 14.06 608 274 4.26 / 665.65 3 5
8 13 40.52 32 14.36 363 167 4.43 / 665.81 3 4
9 8 -0.08 150 14.39 297 641 5.07 / 666.45 3 7
Average= 4.73 (KJ/cycle)

Cycle 139 GMT 31/ 7/2020 23:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 27 14.43 439 171 0.17 / 656.46 3 3
2 12 1104.04 4 7.78 1841 57 0.23 / 656.52 3 3
3 12 2006.68 36 9.35 2929 986 1.21 / 657.50 3 3
4 7 2004.84 24 11.29 3034 822 2.04 / 658.32 3 3
5 13 1875.36 32 12.39 2896 1148 3.18 / 659.47 3 3
6 13 1137.60 32 13.10 1917 804 3.99 / 660.28 3 5
7 13 229.52 32 14.01 663 297 4.29 / 660.57 3 5
8 13 49.04 32 14.34 380 174 4.46 / 660.75 3 5
9 8 -0.12 150 14.38 295 636 5.10 / 661.38 3 10
Average= 4.72 (KJ/cycle)

Cycle 138 GMT 21/ 7/2020 23:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 27 14.45 421 164 0.16 / 651.29 3 3
2 12 1115.88 4 8.33 1781 59 0.22 / 651.35 3 3
3 12 2007.48 36 9.49 2929 1001 1.22 / 652.35 2 3
4 7 2005.76 24 11.33 3031 824 2.05 / 653.18 3 3
5 13 1876.44 32 12.38 2902 1150 3.20 / 654.32 3 3
6 13 1130.56 32 13.10 1908 800 4.00 / 655.12 3 4
7 13 325.64 32 13.90 792 352 4.35 / 655.48 3 5
8 13 41.00 32 14.36 363 167 4.52 / 655.64 3 4
9 8 -0.08 150 14.39 298 643 5.16 / 656.29 3 10
Average= 4.72 (KJ/cycle)

Cycle 137 GMT 11/ 7/2020 23:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 27 14.45 434 169 0.17 / 646.43 3 3
2 12 1124.88 4 8.17 1790 58 0.23 / 646.49 3 3
3 12 2002.64 36 9.60 2914 1007 1.23 / 647.49 2 3
4 7 2000.64 24 11.35 3032 826 2.06 / 648.32 3 3
5 13 1872.00 32 12.38 2892 1146 3.21 / 649.47 3 4
6 13 854.96 32 13.37 1516 649 3.86 / 650.11 3 4
7 13 126.40 32 14.18 501 227 4.08 / 650.34 3 5
8 13 28.88 32 14.39 343 158 4.24 / 650.50 3 4
9 8 0.08 150 14.42 290 627 4.87 / 651.13 3 12
Average= 4.72 (KJ/cycle)

Cycle 136 GMT 1/ 7/2020 23:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 27 14.40 439 171 0.17 / 641.74 3 3
2 12 1118.88 4 9.34 1805 67 0.24 / 641.81 3 3
3 12 2003.20 36 9.81 2967 1048 1.29 / 642.86 3 3
4 7 2001.20 24 11.39 3027 827 2.11 / 643.69 3 3
5 13 1612.28 32 12.67 2549 1033 3.15 / 644.72 3 4
6 13 887.32 32 13.33 1569 669 3.82 / 645.39 3 6
7 13 121.52 32 14.18 495 225 4.04 / 645.61 3 4
8 8 -0.04 150 14.39 299 645 4.69 / 646.26 3 7
Average= 4.72 (KJ/cycle)

Cycle 135 GMT 21/ 6/2020 23:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 27 14.47 420 164 0.16 / 636.80 3 3
2 12 1127.96 4 9.21 1801 66 0.23 / 636.87 3 3
3 12 2002.92 36 9.89 2913 1037 1.27 / 637.90 3 3
4 7 2000.48 24 11.33 3032 824 2.09 / 638.73 3 3
5 13 1723.40 32 12.56 2698 1084 3.18 / 639.81 3 3
6 13 999.64 32 13.22 1724 729 3.91 / 640.54 3 5
7 13 114.12 32 14.20 479 218 4.12 / 640.76 3 5
8 13 57.32 32 14.32 389 178 4.30 / 640.94 3 5
9 8 0.00 150 14.38 295 636 4.94 / 641.57 3 8
Average= 4.72 (KJ/cycle)

Cycle 134 GMT 11/ 6/2020 23:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 27 14.45 428 167 0.17 / 632.01 3 3
2 12 1138.08 4 9.25 1814 67 0.23 / 632.08 3 3
3 12 2009.76 36 9.86 2919 1036 1.27 / 633.11 3 3
4 7 2007.68 25 11.39 3032 863 2.13 / 633.98 3 3
5 13 1874.52 32 12.38 2915 1155 3.29 / 635.13 3 3
6 13 846.32 32 13.37 1517 649 3.94 / 635.78 3 5
7 13 118.84 32 14.19 492 223 4.16 / 636.00 3 5
8 8 -0.04 150 14.40 292 631 4.79 / 636.63 3 10
Average= 4.72 (KJ/cycle)

Cycle 133 GMT 1/ 6/2020 23:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 27 14.45 420 164 0.16 / 627.01 3 3
2 12 1120.20 4 9.71 1809 70 0.23 / 627.08 3 3
3 12 2004.48 36 9.99 2936 1056 1.29 / 628.14 3 3
4 7 2002.56 24 11.38 3032 828 2.12 / 628.97 3 3
5 13 1878.00 32 12.41 2916 1158 3.28 / 630.13 3 3
6 13 965.32 32 13.26 1679 712 3.99 / 630.84 3 4
7 13 111.76 32 14.21 476 216 4.21 / 631.05 3 4
8 13 29.96 32 14.39 338 156 4.36 / 631.21 3 4
9 8 -0.08 150 14.40 293 633 4.99 / 631.84 3 8
Average= 4.72 (KJ/cycle)

Cycle 132 GMT 22/ 5/2020 23:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 27 14.45 443 173 0.17 / 622.17 3 3
2 12 1133.52 4 9.91 1836 73 0.25 / 622.24 3 3
3 12 2002.48 36 10.06 2927 1060 1.31 / 623.30 3 3
4 7 2000.12 24 11.42 3036 832 2.14 / 624.13 3 3
5 13 1602.24 32 12.67 2553 1035 3.17 / 625.17 3 4
6 13 864.48 32 13.36 1551 663 3.84 / 625.83 3 5
7 13 118.76 32 14.19 497 226 4.06 / 626.06 3 5
8 13 27.04 32 14.39 345 159 4.22 / 626.21 3 5
9 8 -0.20 150 14.40 294 635 4.86 / 626.85 3 11
Average= 4.71 (KJ/cycle)

Cycle 131 GMT 12/ 5/2020 23:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 27 14.44 431 168 0.17 / 617.28 3 3
2 12 1114.76 4 9.66 1798 69 0.24 / 617.35 3 3
3 12 2012.64 36 9.86 2977 1057 1.29 / 618.40 3 3
4 7 2010.24 24 11.37 3052 833 2.13 / 619.24 3 3
5 13 1739.68 32 12.56 2718 1092 3.22 / 620.33 2 3
6 13 849.36 32 13.38 1519 650 3.87 / 620.98 3 5
7 13 124.24 32 14.18 500 227 4.10 / 621.21 3 5
8 13 32.48 32 14.39 350 161 4.26 / 621.37 3 4
9 8 -0.04 150 14.41 290 627 4.88 / 621.99 3 7
Average= 4.71 (KJ/cycle)

Cycle 130 GMT 2/ 5/2020 22:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 27 14.46 432 169 0.17 / 612.19 3 3
2 12 1119.56 4 10.19 1825 74 0.24 / 612.26 3 3
3 12 2002.92 36 10.15 2931 1071 1.31 / 613.34 3 3
4 7 2000.72 24 11.41 3023 828 2.14 / 614.16 3 3
5 13 1733.44 32 12.58 2697 1086 3.23 / 615.25 2 3
6 13 1116.60 32 13.13 1892 795 4.02 / 616.04 3 5
7 13 155.20 32 14.12 549 248 4.27 / 616.29 3 5
8 13 35.32 32 14.37 358 165 4.44 / 616.46 3 5
9 8 -0.16 150 14.37 303 653 5.09 / 617.11 3 10
Average= 4.71 (KJ/cycle)

Cycle 129 GMT 22/ 4/2020 22:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 27 14.47 419 164 0.16 / 607.38 3 3
2 12 1115.40 4 10.38 1808 75 0.24 / 607.45 3 3
3 12 2005.92 36 10.17 2935 1075 1.31 / 608.53 2 3
4 7 2003.84 24 11.36 3045 830 2.14 / 609.36 3 3
5 13 1622.56 32 12.66 2575 1043 3.19 / 610.40 2 3
6 13 755.16 32 13.47 1388 598 3.78 / 611.00 3 4
7 13 131.96 32 14.17 512 232 4.02 / 611.23 3 5
8 13 12.80 32 14.41 320 148 4.16 / 611.38 3 4
9 8 -0.08 150 14.36 298 642 4.81 / 612.02 3 10
Average= 4.71 (KJ/cycle)

Cycle 128 GMT 12/ 4/2020 22: 4: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 27 14.45 438 171 0.17 / 602.40 3 3
2 12 1104.48 4 10.41 1807 75 0.25 / 602.47 3 3
3 12 2001.56 36 10.21 2928 1076 1.32 / 603.55 3 3
4 7 1999.12 24 11.42 3024 829 2.15 / 604.38 3 3
5 13 1737.60 32 12.56 2713 1090 3.24 / 605.47 3 3
6 13 971.40 32 13.27 1686 716 3.96 / 606.18 3 4
7 13 102.08 32 14.21 464 211 4.17 / 606.39 3 5
8 13 52.48 32 14.32 386 177 4.35 / 606.57 3 5
9 8 -0.16 150 14.37 299 644 4.99 / 607.21 3 8
Average= 4.71 (KJ/cycle)

Cycle 127 GMT 2/ 4/2020 21:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 27 14.47 424 166 0.17 / 597.44 3 3
2 12 1121.92 4 10.00 1829 73 0.24 / 597.52 3 3
3 12 2002.28 36 10.20 2936 1078 1.32 / 598.59 3 3
4 7 1999.80 24 11.39 3036 830 2.15 / 599.42 3 3
5 13 1728.80 32 12.58 2698 1086 3.23 / 600.51 3 3
6 13 981.48 32 13.26 1703 723 3.96 / 601.23 3 5
7 13 96.56 32 14.24 457 208 4.16 / 601.44 3 4
8 13 21.28 32 14.41 333 154 4.32 / 601.59 3 4
9 8 -0.04 150 14.40 292 631 4.95 / 602.22 3 8
Average= 4.70 (KJ/cycle)

Cycle 126 GMT 23/ 3/2020 21:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 28 14.47 435 176 0.18 / 592.36 3 3
2 12 1121.52 4 10.30 1837 76 0.25 / 592.43 3 3
3 12 2001.36 36 10.28 2945 1090 1.34 / 593.52 3 3
4 7 1998.72 24 11.41 3016 826 2.17 / 594.35 3 3
5 13 1724.68 32 12.59 2707 1091 3.26 / 595.44 3 3
6 13 1113.52 32 13.14 1889 794 4.05 / 596.23 3 5
7 13 143.44 32 14.17 530 240 4.29 / 596.47 3 5
8 13 33.56 32 14.40 349 161 4.45 / 596.64 3 4
9 8 -0.20 150 14.40 297 642 5.10 / 597.28 3 9
Average= 4.70 (KJ/cycle)

Cycle 125 GMT 13/ 3/2020 20:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 28 14.45 442 179 0.18 / 587.50 3 3
2 12 1103.60 4 10.36 1815 75 0.25 / 587.58 3 3
3 12 2002.00 36 10.27 2944 1088 1.34 / 588.67 3 3
4 7 1999.36 24 11.39 3039 831 2.17 / 589.50 3 3
5 13 1729.76 32 12.58 2703 1088 3.26 / 590.58 3 4
6 13 732.32 32 13.50 1356 586 3.85 / 591.17 3 5
7 13 133.88 32 14.20 501 228 4.07 / 591.40 3 4
8 13 32.68 32 14.42 339 156 4.23 / 591.55 3 4
9 8 -0.08 150 14.42 290 627 4.86 / 592.18 3 8
Average= 4.70 (KJ/cycle)

Cycle 124 GMT 3/ 3/2020 20:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 27 14.46 429 167 0.17 / 582.60 3 3
2 3 1020.00 1 10.15 1744 18 0.19 / 582.62 3 3
3 3 1019.96 1 10.48 1753 18 0.20 / 582.64 3 3
4 12 1141.48 4 10.44 1867 78 0.28 / 582.72 3 3
5 12 2002.80 36 10.33 2959 1100 1.38 / 583.82 3 3
6 7 2000.20 24 11.40 3036 831 2.21 / 584.65 3 3
7 13 1725.60 32 12.58 2728 1098 3.31 / 585.75 3 3
8 13 703.68 32 13.53 1322 572 3.88 / 586.32 3 4
9 13 117.20 32 14.23 487 222 4.10 / 586.54 3 4
10 13 32.12 32 14.42 339 156 4.26 / 586.70 3 4
11 8 -0.08 150 14.42 290 627 4.89 / 587.32 3 8
Average= 4.70 (KJ/cycle)

Cycle 123 GMT 22/ 2/2020 19:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 27 14.48 427 167 0.17 / 577.71 3 3
2 12 1111.80 4 10.44 1821 76 0.24 / 577.78 3 3
3 12 2004.32 36 10.35 2963 1104 1.35 / 578.89 3 3
4 7 2001.92 24 11.41 3045 834 2.18 / 579.72 3 3
5 13 1599.96 32 12.70 2550 1036 3.22 / 580.76 3 4
6 13 872.76 32 13.37 1558 667 3.88 / 581.42 3 4
7 13 123.20 32 14.20 498 226 4.11 / 581.65 3 4
8 13 31.60 32 14.43 339 157 4.27 / 581.81 3 4
9 8 -0.12 150 14.42 290 627 4.89 / 582.43 3 8
Average= 4.70 (KJ/cycle)

Cycle 122 GMT 12/ 2/2020 19: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 27 14.48 422 165 0.16 / 572.71 3 3
2 12 1122.24 4 10.78 1846 80 0.24 / 572.79 3 3
3 12 2001.28 36 10.34 2950 1098 1.34 / 573.89 3 3
4 7 1998.56 24 11.40 3067 839 2.18 / 574.73 3 3
5 13 1587.12 32 12.71 2541 1033 3.22 / 575.76 3 4
6 13 971.48 32 13.27 1705 724 3.94 / 576.49 3 4
7 13 172.28 32 14.14 575 260 4.20 / 576.75 3 5
8 13 37.64 32 14.41 354 163 4.36 / 576.91 3 4
9 8 -0.16 150 14.41 292 631 4.99 / 577.54 3 8
Average= 4.70 (KJ/cycle)

Cycle 121 GMT 2/ 2/2020 18:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 27 14.48 451 176 0.18 / 567.66 3 3
2 12 1129.88 4 10.60 1851 78 0.25 / 567.74 3 3
3 12 2002.36 36 10.35 2963 1104 1.36 / 568.84 3 3
4 7 2000.24 24 11.39 3032 829 2.19 / 569.67 3 3
5 13 1887.72 32 12.42 2933 1166 3.35 / 570.83 3 3
6 13 824.84 32 13.42 1489 639 3.99 / 571.47 3 5
7 13 204.24 32 14.10 614 277 4.27 / 571.75 3 5
8 13 41.36 32 14.41 353 163 4.43 / 571.91 3 4
9 8 -0.16 150 14.41 293 633 5.07 / 572.55 3 9
Average= 4.69 (KJ/cycle)

Cycle 120 GMT 23/ 1/2020 18:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 27 14.48 425 166 0.17 / 562.48 3 3
2 12 1143.64 4 10.80 1882 81 0.25 / 562.56 3 3
3 12 2003.36 36 10.39 2967 1110 1.36 / 563.67 3 3
4 7 2001.08 24 11.41 3027 829 2.19 / 564.50 3 3
5 13 1877.44 32 12.43 2927 1164 3.35 / 565.66 3 3
6 13 1083.40 32 13.20 1852 782 4.13 / 566.45 3 4
7 13 141.04 32 14.20 524 238 4.37 / 566.68 3 4
8 13 34.36 32 14.43 347 160 4.53 / 566.84 3 4
9 8 0.00 150 14.42 294 636 5.17 / 567.48 3 7
Average= 4.69 (KJ/cycle)

Cycle 119 GMT 13/ 1/2020 18:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 27 14.50 415 162 0.16 / 557.30 3 3
2 12 1105.00 4 10.65 1830 78 0.24 / 557.38 3 3
3 12 2006.44 36 10.36 2961 1104 1.34 / 558.48 3 3
4 7 2004.40 24 11.43 3052 837 2.18 / 559.32 3 3
5 13 1872.84 32 12.44 2907 1157 3.34 / 560.48 3 4
6 13 1089.20 32 13.18 1861 785 4.12 / 561.26 3 5
7 13 144.68 32 14.19 528 240 4.36 / 561.50 3 4
8 13 74.08 32 14.35 406 186 4.55 / 561.69 3 4
9 8 -0.12 150 14.44 289 626 5.18 / 562.31 3 10
Average= 4.69 (KJ/cycle)

Cycle 118 GMT 3/ 1/2020 18: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 27 14.49 439 172 0.17 / 552.18 3 3
2 12 1118.16 4 10.38 1832 76 0.25 / 552.26 3 3
3 12 2013.92 36 10.35 2956 1101 1.35 / 553.36 3 3
4 7 2011.80 25 11.39 3048 868 2.22 / 554.23 3 3
5 13 1884.32 32 12.43 2917 1160 3.38 / 555.39 3 3
6 13 994.88 32 13.27 1731 735 4.11 / 556.12 3 6
7 13 114.08 32 14.26 474 216 4.33 / 556.34 3 4
8 13 58.08 32 14.39 381 175 4.50 / 556.52 3 4
9 8 0.00 150 14.44 287 622 5.13 / 557.14 3 7
Average= 4.68 (KJ/cycle)

Cycle 117 GMT 24/12/2019 17:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 27 14.49 449 176 0.18 / 547.14 3 3
2 12 1144.44 4 10.32 1877 77 0.25 / 547.21 3 3
3 12 1999.44 36 10.38 2944 1100 1.35 / 548.31 3 3
4 7 1996.48 24 11.40 3056 836 2.19 / 549.15 3 3
5 13 1719.56 32 12.60 2718 1096 3.29 / 550.25 3 4
6 13 953.92 32 13.31 1677 714 4.00 / 550.96 3 4
7 13 169.04 32 14.17 560 254 4.25 / 551.21 3 4
8 13 33.80 32 14.43 345 159 4.41 / 551.37 3 4
9 8 -0.08 150 14.42 295 638 5.05 / 552.01 3 6
Average= 4.68 (KJ/cycle)

Cycle 116 GMT 14/12/2019 16:55:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 27 14.49 435 170 0.17 / 542.10 3 3
2 12 1123.56 4 10.33 1836 76 0.25 / 542.18 3 3
3 12 2001.48 36 10.37 2960 1105 1.35 / 543.29 3 3
4 7 1998.88 24 11.39 3088 844 2.20 / 544.13 3 3
5 13 1864.08 32 12.46 2920 1164 3.36 / 545.29 3 3
6 13 795.28 32 13.46 1453 626 3.99 / 545.92 3 4
7 13 176.88 32 14.16 576 261 4.25 / 546.18 3 4
8 13 21.20 32 14.47 323 150 4.40 / 546.33 3 4
9 8 0.00 150 14.44 291 630 5.03 / 546.96 3 7
Average= 4.67 (KJ/cycle)

Cycle 115 GMT 4/12/2019 16:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 27 14.49 433 169 0.17 / 536.98 3 3
2 12 1125.68 4 10.58 1846 78 0.25 / 537.06 3 3
3 12 2007.64 36 10.51 2955 1118 1.37 / 538.18 3 3
4 7 2005.48 24 11.50 3039 839 2.20 / 539.02 3 3
5 13 1873.40 32 12.47 2918 1164 3.37 / 540.18 3 3
6 13 946.44 32 13.33 1662 709 4.08 / 540.89 3 5
7 13 155.28 32 14.19 545 247 4.33 / 541.14 3 4
8 13 36.60 32 14.45 342 158 4.48 / 541.30 3 4
9 8 -0.08 150 14.43 295 639 5.12 / 541.93 3 7
Average= 4.67 (KJ/cycle)

Cycle 114 GMT 24/11/2019 16:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 27 14.51 416 163 0.16 / 531.90 3 3
2 12 1113.88 4 10.93 1833 80 0.24 / 531.98 3 3
3 12 2001.36 36 10.52 2950 1117 1.36 / 533.09 3 3
4 7 1998.76 24 11.45 3034 834 2.19 / 533.93 3 3
5 13 1730.44 32 12.61 2718 1097 3.29 / 535.02 3 3
6 13 1111.92 32 13.18 1894 799 4.09 / 535.82 3 4
7 13 136.12 32 14.21 510 232 4.32 / 536.05 3 4
8 13 32.76 32 14.44 333 154 4.48 / 536.21 3 4
9 8 -0.08 150 14.44 279 604 5.08 / 536.81 3 8
Average= 4.67 (KJ/cycle)

Cycle 113 GMT 14/11/2019 15:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 27 14.48 427 167 0.17 / 527.12 3 3
2 12 1128.48 4 10.97 1842 81 0.25 / 527.20 3 3
3 12 2004.12 36 10.49 2977 1124 1.37 / 528.32 3 3
4 7 2001.52 24 11.42 3059 838 2.21 / 529.16 3 3
5 13 1737.40 32 12.63 2729 1103 3.31 / 530.26 3 3
6 13 825.76 32 13.44 1487 640 3.95 / 530.90 3 4
7 13 101.80 32 14.28 455 208 4.16 / 531.11 3 4
8 8 0.00 150 14.44 288 624 4.78 / 531.73 3 6
Average= 4.66 (KJ/cycle)

Cycle 112 GMT 4/11/2019 15: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 27 14.48 424 166 0.17 / 522.01 3 3
2 12 1113.48 4 11.24 1839 83 0.25 / 522.10 3 3
3 12 2011.84 36 10.59 2976 1135 1.38 / 523.23 3 3
4 7 2009.72 24 11.45 3052 839 2.22 / 524.07 3 3
5 13 1876.04 32 12.46 2926 1167 3.39 / 525.24 3 3
6 13 936.32 32 13.33 1647 703 4.09 / 525.94 3 4
7 13 78.20 32 14.29 428 196 4.29 / 526.14 3 4
8 13 39.56 32 14.36 365 168 4.45 / 526.30 3 5
9 8 -0.08 150 14.38 299 645 5.10 / 526.95 3 10
Average= 4.66 (KJ/cycle)

Cycle 111 GMT 25/10/2019 14:34: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 27 14.49 421 165 0.16 / 516.92 3 3
2 12 1132.16 4 11.05 1859 82 0.25 / 517.00 3 3
3 12 2000.96 36 10.66 2977 1142 1.39 / 518.15 3 3
4 7 1998.64 24 11.39 3081 842 2.23 / 518.99 3 3
5 13 1865.72 32 12.46 2902 1157 3.39 / 520.14 3 3
6 13 947.12 32 13.32 1654 705 4.09 / 520.85 3 5
7 13 96.04 32 14.27 452 206 4.30 / 521.06 3 4
8 13 20.40 32 14.43 327 151 4.45 / 521.21 3 5
9 8 -0.16 150 14.37 298 642 5.09 / 521.85 3 13
Average= 4.66 (KJ/cycle)

Cycle 110 GMT 15/10/2019 14:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 27 14.48 416 163 0.16 / 512.28 3 3
2 12 1119.04 4 11.08 1847 82 0.24 / 512.36 3 3
3 12 2002.64 36 10.56 3005 1142 1.39 / 513.51 3 3
4 7 2000.24 24 11.43 3076 844 2.23 / 514.35 3 3
5 13 1464.96 32 12.84 2384 980 3.21 / 515.33 3 6
6 13 730.32 32 13.52 1367 591 3.80 / 515.92 3 5
7 13 73.96 32 14.30 424 194 4.00 / 516.11 3 4
8 8 -0.16 150 14.40 297 642 4.64 / 516.76 3 9
Average= 4.66 (KJ/cycle)

Cycle 109 GMT 5/10/2019 13:52:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 27 14.49 427 167 0.17 / 507.59 3 3
2 12 1131.28 4 11.23 1863 84 0.25 / 507.67 3 3
3 12 2002.12 36 10.71 2968 1144 1.40 / 508.82 3 3
4 7 1999.60 24 11.46 3039 836 2.23 / 509.65 3 3
5 13 1586.76 32 12.74 2532 1032 3.26 / 510.68 3 4
6 13 713.04 32 13.54 1340 581 3.84 / 511.26 3 4
7 13 105.64 32 14.24 471 215 4.06 / 511.48 3 5
8 8 -0.12 150 14.40 296 639 4.70 / 512.12 3 5
Average= 4.66 (KJ/cycle)

Cycle 108 GMT 25/ 9/2019 13:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 27 14.47 435 170 0.17 / 502.74 3 3
2 12 1107.12 4 11.33 1828 83 0.25 / 502.83 3 3
3 12 2000.16 36 10.61 3004 1147 1.40 / 503.97 3 3
4 7 1997.56 24 11.45 3073 844 2.24 / 504.82 3 3
5 13 1723.20 32 12.63 2716 1098 3.34 / 505.92 3 4
6 13 841.20 32 13.42 1523 654 4.00 / 506.57 3 6
7 13 84.48 32 14.27 443 202 4.20 / 506.77 3 4
8 8 0.04 150 14.39 300 648 4.85 / 507.42 3 7
Average= 4.66 (KJ/cycle)

Cycle 107 GMT 15/ 9/2019 13: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 27 14.49 426 167 0.17 / 497.90 3 3
2 12 1135.36 4 11.06 1869 83 0.25 / 497.98 3 3
3 12 1998.52 36 10.59 2962 1129 1.38 / 499.11 3 3
4 7 1995.72 24 11.45 3056 840 2.22 / 499.95 3 3
5 13 1860.92 32 12.48 2904 1160 3.38 / 501.11 3 3
6 13 796.04 32 13.46 1450 625 4.00 / 501.73 3 5
7 13 76.16 32 14.31 420 192 4.19 / 501.93 3 4
8 8 -0.12 150 14.38 301 649 4.84 / 502.57 3 6
Average= 4.65 (KJ/cycle)

Cycle 106 GMT 5/ 9/2019 11:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 27 14.49 437 171 0.17 / 492.68 3 3
2 12 1133.08 4 11.52 1866 86 0.26 / 492.77 3 3
3 12 2003.20 36 10.77 2978 1155 1.41 / 493.92 3 3
4 7 2000.60 24 11.46 3072 845 2.26 / 494.77 3 3
5 13 1866.72 32 12.45 2906 1158 3.41 / 495.92 3 3
6 13 1074.28 32 13.20 1846 780 4.19 / 496.70 3 5
7 13 124.48 32 14.22 507 231 4.42 / 496.93 3 5
8 13 14.32 32 14.44 323 149 4.57 / 497.08 3 5
9 8 -0.16 150 14.37 300 647 5.22 / 497.73 3 7
Average= 4.65 (KJ/cycle)

Cycle 105 GMT 26/ 8/2019 12: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 27 14.49 435 170 0.17 / 488.01 3 3
2 12 1134.52 4 11.37 1865 85 0.26 / 488.10 3 3
3 12 2002.56 36 10.75 2988 1156 1.41 / 489.25 3 3
4 7 2000.00 24 11.45 3082 847 2.26 / 490.10 3 3
5 13 1462.52 32 12.84 2374 975 3.23 / 491.07 3 6
6 13 752.92 32 13.51 1400 605 3.84 / 491.68 3 5
7 13 72.04 32 14.32 412 189 4.03 / 491.87 3 4
8 8 -0.08 150 14.40 297 642 4.67 / 492.51 3 9
Average= 4.65 (KJ/cycle)

Cycle 104 GMT 16/ 8/2019 11:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 27 14.50 417 163 0.16 / 483.36 3 3
2 12 1111.40 4 11.48 1842 85 0.25 / 483.44 3 3
3 12 2000.84 36 10.65 3008 1153 1.40 / 484.60 3 3
4 7 1998.16 24 11.47 3057 842 2.24 / 485.44 3 3
5 13 1453.44 32 12.86 2358 970 3.21 / 486.41 3 3
6 13 718.96 32 13.54 1353 586 3.80 / 487.00 3 5
7 13 109.76 32 14.25 479 218 4.02 / 487.21 3 5
8 8 -0.16 150 14.41 290 627 4.64 / 487.84 3 6
Average= 4.65 (KJ/cycle)

Cycle 103 GMT 6/ 8/2019 10:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 27 14.51 430 168 0.17 / 478.53 3 3
2 12 1099.36 4 11.38 1822 83 0.25 / 478.61 3 3
3 12 2000.60 36 10.74 2968 1148 1.40 / 479.76 3 3
4 7 1998.00 24 11.46 3059 841 2.24 / 480.60 3 3
5 13 1724.44 32 12.61 2721 1098 3.34 / 481.70 3 3
6 13 846.48 32 13.42 1526 655 3.99 / 482.36 3 5
7 13 93.60 32 14.27 456 208 4.20 / 482.56 3 5
8 8 0.04 150 14.41 292 631 4.83 / 483.20 3 8
Average= 4.65 (KJ/cycle)

Cycle 102 GMT 27/ 7/2019 9:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 27 14.49 434 170 0.17 / 473.72 3 3
2 12 1124.24 4 11.45 1861 85 0.26 / 473.81 3 3
3 12 2000.72 36 10.64 3023 1158 1.41 / 474.97 3 3
4 7 1998.00 24 11.49 3073 847 2.26 / 475.81 3 3
5 13 1604.00 32 12.75 2554 1042 3.30 / 476.86 3 3
6 13 851.32 32 13.41 1536 659 3.96 / 477.51 3 5
7 13 103.80 32 14.28 465 212 4.17 / 477.73 3 4
8 8 0.04 150 14.42 294 636 4.81 / 478.36 3 6
Average= 4.64 (KJ/cycle)

Cycle 101 GMT 17/ 7/2019 9:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 27 14.50 427 167 0.17 / 468.63 3 3
2 12 1118.36 4 11.53 1853 85 0.25 / 468.72 3 3
3 12 2004.92 36 10.66 3015 1157 1.41 / 469.87 3 3
4 7 2002.20 24 11.48 3080 849 2.26 / 470.72 3 3
5 13 1741.68 32 12.61 2740 1106 3.36 / 471.83 3 3
6 13 974.32 32 13.31 1703 725 4.09 / 472.55 3 5
7 13 90.96 32 14.31 440 201 4.29 / 472.75 3 5
8 13 47.44 32 14.37 371 171 4.46 / 472.92 3 4
9 8 -0.24 150 14.40 291 629 5.09 / 473.55 3 11
Average= 4.64 (KJ/cycle)

Cycle 100 GMT 7/ 7/2019 8: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 27 14.49 431 169 0.17 / 463.93 3 3
2 12 1131.80 4 11.59 1866 87 0.26 / 464.02 3 3
3 12 2001.40 36 10.87 2989 1170 1.42 / 465.19 3 3
4 7 1998.72 24 11.50 3073 848 2.27 / 466.04 3 3
5 13 1580.76 32 12.75 2522 1029 3.30 / 467.07 3 3
6 13 673.84 32 13.58 1287 559 3.86 / 467.63 3 5
7 13 94.44 32 14.28 453 207 4.07 / 467.83 3 5
8 8 -0.12 150 14.41 292 631 4.70 / 468.46 3 8
Average= 4.64 (KJ/cycle)

Cycle 99 GMT 27/ 6/2019 7:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 27 14.50 438 171 0.17 / 459.12 3 3
2 12 1122.84 4 11.56 1866 86 0.26 / 459.20 3 3
3 12 2000.32 36 10.88 2964 1161 1.42 / 460.36 3 3
4 7 1997.72 24 11.46 3068 844 2.26 / 461.21 3 3
5 13 1607.96 32 12.74 2560 1044 3.31 / 462.25 3 5
6 13 600.76 32 13.66 1186 518 3.82 / 462.77 3 4
7 13 74.28 32 14.33 417 191 4.02 / 462.96 3 4
8 13 41.64 32 14.38 365 168 4.18 / 463.13 3 5
9 8 -0.16 150 14.40 294 635 4.82 / 463.76 3 8
Average= 4.64 (KJ/cycle)

Cycle 98 GMT 17/ 6/2019 7: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 27 14.52 432 169 0.17 / 454.29 3 3
2 12 1107.76 4 11.41 1835 84 0.25 / 454.37 3 3
3 12 2001.28 36 10.67 3002 1153 1.41 / 455.52 3 3
4 7 1998.40 24 11.52 3070 849 2.26 / 456.37 3 3
5 13 1472.80 32 12.87 2377 979 3.23 / 457.35 3 4
6 13 735.52 32 13.53 1372 594 3.83 / 457.94 3 5
7 13 71.72 32 14.34 421 193 4.02 / 458.14 3 4
8 13 36.40 32 14.38 362 167 4.19 / 458.30 3 4
9 8 -0.04 150 14.39 297 641 4.83 / 458.95 3 12
Average= 4.64 (KJ/cycle)

Cycle 97 GMT 7/ 6/2019 6:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 27 14.55 427 168 0.17 / 449.33 3 3
2 12 1123.04 4 11.60 1858 86 0.25 / 449.41 3 3
3 12 2000.04 36 10.84 2986 1165 1.42 / 450.58 3 3
4 7 1997.08 24 11.49 3073 847 2.27 / 451.42 3 3
5 13 1604.08 32 12.75 2540 1036 3.30 / 452.46 3 3
6 13 858.68 32 13.42 1537 660 3.96 / 453.12 3 5
7 13 99.48 32 14.28 465 212 4.18 / 453.33 3 5
8 13 25.76 32 14.44 333 154 4.33 / 453.49 3 5
9 8 -0.04 150 14.40 291 629 4.96 / 454.12 3 8
Average= 4.63 (KJ/cycle)

Cycle 96 GMT 28/ 5/2019 5:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 27 14.50 432 169 0.17 / 444.49 3 3
2 12 1115.84 4 11.44 1841 84 0.25 / 444.57 3 3
3 12 2001.16 36 10.89 2972 1165 1.42 / 445.74 3 3
4 7 1998.52 24 11.50 3083 851 2.27 / 446.59 3 3
5 13 1472.80 32 12.87 2362 973 3.24 / 447.56 3 5
6 13 729.80 32 13.55 1365 592 3.83 / 448.15 3 5
7 13 73.44 32 14.34 423 194 4.03 / 448.35 3 4
8 13 42.20 32 14.38 368 169 4.20 / 448.51 3 4
9 8 -0.08 150 14.40 298 644 4.84 / 449.16 3 10
Average= 4.63 (KJ/cycle)

Cycle 95 GMT 18/ 5/2019 4:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 27 14.52 422 165 0.17 / 439.62 3 3
2 12 1116.48 4 11.61 1844 86 0.25 / 439.70 3 3
3 12 1999.04 36 10.93 2971 1169 1.42 / 440.87 3 3
4 7 1996.00 24 11.55 3057 847 2.27 / 441.72 3 3
5 13 1581.00 32 12.77 2530 1034 3.30 / 442.75 3 5
6 13 697.40 32 13.57 1318 572 3.87 / 443.32 3 5
7 13 94.40 32 14.30 453 207 4.08 / 443.53 3 4
8 13 23.08 32 14.44 335 155 4.24 / 443.69 3 5
9 8 0.00 150 14.39 292 630 4.87 / 444.32 3 10
Average= 4.63 (KJ/cycle)

Cycle 94 GMT 8/ 5/2019 3:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 27 14.52 428 168 0.17 / 434.80 3 3
2 12 1118.60 4 11.43 1856 85 0.25 / 434.88 3 3
3 12 1999.16 36 10.94 2970 1170 1.42 / 436.05 3 3
4 7 1996.24 24 11.54 3068 850 2.27 / 436.90 3 3
5 13 1596.52 32 12.76 2552 1042 3.31 / 437.94 3 4
6 13 602.36 32 13.67 1187 519 3.83 / 438.46 3 5
7 13 71.56 32 14.35 413 190 4.02 / 438.65 3 4
8 13 39.04 32 14.39 358 165 4.19 / 438.82 3 4
9 8 -0.12 150 14.40 294 635 4.82 / 439.45 3 8
Average= 4.63 (KJ/cycle)

Cycle 93 GMT 28/ 4/2019 2:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 27 14.51 432 169 0.17 / 429.95 3 3
2 12 1121.84 4 11.39 1853 84 0.25 / 430.04 3 3
3 12 2004.20 36 10.73 3007 1162 1.42 / 431.20 3 3
4 7 2001.44 24 11.58 3026 841 2.26 / 432.04 3 3
5 13 1593.60 32 12.78 2533 1036 3.29 / 433.08 3 4
6 13 688.00 32 13.58 1312 570 3.86 / 433.65 3 5
7 13 63.20 32 14.36 404 186 4.05 / 433.83 3 4
8 13 17.80 32 14.45 328 152 4.20 / 433.98 3 4
9 8 -0.20 150 14.38 299 645 4.84 / 434.63 3 10
Average= 4.62 (KJ/cycle)

Cycle 92 GMT 18/ 4/2019 1:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 27 14.52 433 170 0.17 / 425.01 3 3
2 12 1126.64 4 11.60 1866 87 0.26 / 425.09 3 3
3 12 2000.72 36 10.99 2973 1176 1.43 / 426.27 3 3
4 7 1998.12 24 11.59 3039 845 2.28 / 427.11 3 3
5 13 1581.40 32 12.79 2506 1026 3.30 / 428.14 3 3
6 13 820.56 32 13.46 1494 643 3.95 / 428.78 3 5
7 13 89.08 32 14.31 446 204 4.15 / 428.99 3 5
8 13 26.28 32 14.44 337 156 4.31 / 429.14 3 5
9 8 -0.16 150 14.39 297 641 4.95 / 429.78 3 7
Average= 4.62 (KJ/cycle)

Cycle 91 GMT 8/ 4/2019 0:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 27 14.54 429 168 0.17 / 420.31 3 3
2 12 1142.92 4 11.55 1880 87 0.26 / 420.40 3 3
3 12 1999.72 36 11.02 2980 1182 1.44 / 421.58 3 3
4 7 1996.72 24 11.55 3063 849 2.29 / 422.43 3 3
5 13 1416.12 32 12.92 2293 948 3.23 / 423.37 3 4
6 13 557.68 32 13.72 1123 493 3.73 / 423.87 3 5
7 13 68.28 32 14.37 404 186 3.91 / 424.05 3 4
8 13 19.12 32 14.47 323 150 4.06 / 424.20 3 4
9 8 -0.12 150 14.39 293 632 4.70 / 424.84 3 8
Average= 4.62 (KJ/cycle)

Cycle 90 GMT 28/ 3/2019 23:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 27 14.51 430 168 0.17 / 415.60 3 3
2 12 1119.28 4 11.29 1837 83 0.25 / 415.68 3 3
3 12 2003.84 36 10.97 2963 1170 1.42 / 416.85 3 3
4 7 2001.44 24 11.60 3035 845 2.27 / 417.70 3 3
5 13 1451.68 32 12.92 2337 966 3.23 / 418.66 3 4
6 13 556.28 32 13.72 1124 493 3.73 / 419.16 3 5
7 13 74.04 32 14.37 411 189 3.92 / 419.35 3 4
8 13 40.64 32 14.41 356 164 4.08 / 419.51 3 4
9 8 -0.08 150 14.42 291 629 4.71 / 420.14 3 8
Average= 4.62 (KJ/cycle)

Cycle 89 GMT 18/ 3/2019 22:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 27 14.53 426 167 0.17 / 410.76 3 3
2 12 1115.04 4 11.20 1829 82 0.25 / 410.85 3 3
3 12 2002.72 36 11.02 2964 1176 1.42 / 412.02 3 3
4 7 2000.00 24 11.66 3025 847 2.27 / 412.87 3 3
5 13 1460.88 32 12.90 2364 976 3.25 / 413.84 3 3
6 13 731.32 32 13.56 1367 593 3.84 / 414.44 3 5
7 13 73.88 32 14.37 416 191 4.03 / 414.63 3 4
8 13 38.24 32 14.42 361 167 4.20 / 414.80 3 4
9 8 -0.16 150 14.41 294 635 4.83 / 415.43 3 12
Average= 4.62 (KJ/cycle)

Cycle 88 GMT 8/ 3/2019 21:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 27 14.54 433 170 0.17 / 405.77 3 3
2 12 1122.04 4 11.06 1850 82 0.25 / 405.85 3 3
3 12 2002.04 36 10.98 2975 1176 1.43 / 407.02 3 3
4 7 1999.24 24 11.62 3033 846 2.27 / 407.87 3 3
5 13 1727.84 32 12.70 2722 1106 3.38 / 408.98 3 4
6 13 807.12 32 13.49 1473 636 4.02 / 409.61 3 5
7 13 91.32 32 14.34 443 203 4.22 / 409.82 3 4
8 13 24.80 32 14.47 334 155 4.37 / 409.97 3 4
9 8 -0.08 150 14.43 290 628 5.00 / 410.60 3 8
Average= 4.61 (KJ/cycle)

Cycle 87 GMT 26/ 2/2019 21: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 27 14.52 440 172 0.17 / 400.84 3 3
2 12 1109.56 4 10.82 1825 79 0.25 / 400.92 3 3
3 12 2002.12 36 10.99 2984 1181 1.43 / 402.10 3 3
4 7 1999.44 24 11.70 3032 851 2.28 / 402.95 3 3
5 13 1447.00 32 12.96 2343 972 3.26 / 403.92 3 4
6 13 835.56 32 13.48 1512 652 3.91 / 404.57 3 6
7 13 96.52 32 14.33 454 208 4.12 / 404.78 3 4
8 13 49.40 32 14.40 377 174 4.29 / 404.95 3 4
9 8 -0.16 150 14.41 297 642 4.93 / 405.60 3 8
Average= 4.61 (KJ/cycle)

Cycle 86 GMT 16/ 2/2019 20:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 27 14.54 424 166 0.17 / 395.93 3 3
2 12 1117.80 4 11.04 1841 81 0.25 / 396.01 3 3
3 12 2006.24 36 10.96 3011 1188 1.44 / 397.20 3 3
4 7 2003.84 24 11.75 3036 856 2.29 / 398.06 3 3
5 13 1611.24 32 12.83 2555 1049 3.34 / 399.11 3 4
6 13 686.36 32 13.62 1306 569 3.91 / 399.67 3 5
7 13 97.68 32 14.32 454 208 4.12 / 399.88 3 4
8 13 20.44 32 14.48 325 151 4.27 / 400.03 3 4
9 8 -0.04 150 14.42 292 632 4.90 / 400.66 3 10
Average= 4.61 (KJ/cycle)

Cycle 85 GMT 6/ 2/2019 19:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 27 14.55 426 167 0.17 / 391.36 3 3
2 12 1119.84 4 10.44 1833 77 0.24 / 391.44 3 3
3 12 2003.96 36 10.89 3015 1182 1.43 / 392.62 3 3
4 7 2001.44 24 11.70 3027 850 2.28 / 393.47 3 3
5 13 1455.28 32 12.96 2353 976 3.25 / 394.44 3 3
6 13 571.04 32 13.74 1147 504 3.76 / 394.95 3 5
7 13 68.40 32 14.40 404 186 3.94 / 395.13 3 4
8 8 -0.12 150 14.43 291 630 4.57 / 395.76 3 5
Average= 4.60 (KJ/cycle)

Cycle 84 GMT 27/ 1/2019 19:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 27 14.55 422 166 0.17 / 386.50 3 3
2 12 1113.04 4 10.32 1822 75 0.24 / 386.57 3 3
3 12 2004.92 36 10.85 2998 1171 1.41 / 387.74 3 3
4 7 2002.20 24 11.71 3039 854 2.27 / 388.60 3 3
5 13 1577.00 32 12.86 2523 1038 3.30 / 389.64 3 4
6 13 679.76 32 13.65 1292 564 3.87 / 390.20 3 5
7 13 105.92 32 14.33 462 212 4.08 / 390.41 3 4
8 13 23.60 32 14.49 332 154 4.23 / 390.57 3 4
9 8 -0.20 150 14.43 289 626 4.86 / 391.19 3 9
Average= 4.60 (KJ/cycle)

Cycle 83 GMT 17/ 1/2019 18:40: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 27 14.56 434 171 0.17 / 381.73 3 3
2 12 1132.36 4 10.09 1844 74 0.25 / 381.80 3 3
3 12 2001.68 36 11.04 2968 1180 1.42 / 382.98 3 3
4 7 1998.88 24 11.70 3024 849 2.27 / 383.83 3 3
5 13 1578.36 32 12.88 2520 1039 3.31 / 384.87 3 3
6 13 809.44 32 13.53 1472 637 3.95 / 385.50 3 4
7 13 87.08 32 14.38 427 196 4.15 / 385.70 3 4
8 8 0.00 150 14.46 291 631 4.78 / 386.33 3 7
Average= 4.60 (KJ/cycle)

Cycle 82 GMT 7/ 1/2019 18:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 27 14.55 439 172 0.17 / 376.72 3 3
2 12 1126.28 4 10.39 1822 76 0.25 / 376.80 3 3
3 12 2000.00 36 10.85 3002 1173 1.42 / 377.97 3 3
4 7 1996.88 24 11.73 3031 853 2.27 / 378.82 3 3
5 13 1722.00 32 12.76 2720 1111 3.38 / 379.93 3 4
6 13 808.32 32 13.54 1468 636 4.02 / 380.57 3 6
7 13 86.64 32 14.38 431 198 4.22 / 380.77 3 4
8 13 20.80 32 14.50 325 151 4.37 / 380.92 3 4
9 8 0.04 150 14.43 294 636 5.01 / 381.56 3 7
Average= 4.60 (KJ/cycle)

Cycle 81 GMT 28/12/2018 17:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 27 14.53 436 171 0.17 / 372.02 3 3
2 12 1102.76 4 10.51 1809 76 0.25 / 372.10 3 3
3 12 1999.92 36 10.91 3007 1181 1.43 / 373.28 3 3
4 7 1997.00 25 11.75 3038 892 2.32 / 374.17 3 3
5 13 1444.28 32 12.99 2355 979 3.30 / 375.15 3 4
6 13 699.20 32 13.64 1328 580 3.88 / 375.73 3 5
7 13 52.76 32 14.42 387 179 4.06 / 375.91 3 4
8 8 0.00 150 14.42 296 640 4.70 / 376.55 3 6
Average= 4.59 (KJ/cycle)

Cycle 80 GMT 18/12/2018 17:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 27 14.53 439 172 0.17 / 367.21 3 3
2 12 1115.72 4 10.18 1816 74 0.25 / 367.28 3 3
3 12 2002.16 36 11.00 2974 1178 1.42 / 368.46 3 3
4 7 1999.56 24 11.65 3089 864 2.29 / 369.32 3 3
5 13 1559.60 32 12.92 2488 1029 3.32 / 370.35 3 3
6 13 821.04 32 13.54 1487 644 3.96 / 371.00 3 4
7 13 78.12 32 14.35 432 198 4.16 / 371.20 3 5
8 8 -0.12 150 14.41 303 655 4.81 / 371.85 3 7
Average= 4.59 (KJ/cycle)

Cycle 79 GMT 8/12/2018 17:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 26 14.53 442 167 0.17 / 362.37 3 3
2 12 1131.04 4 10.32 1856 77 0.24 / 362.45 3 3
3 12 1999.04 36 11.08 2970 1185 1.43 / 363.63 3 3
4 7 1995.96 24 11.76 3033 856 2.28 / 364.49 3 3
5 13 1573.68 32 12.92 2504 1035 3.32 / 365.52 3 4
6 13 822.32 32 13.54 1494 647 3.97 / 366.17 3 4
7 13 73.20 32 14.34 432 198 4.17 / 366.37 3 5
8 8 -0.12 150 14.37 311 670 4.84 / 367.04 3 9
Average= 4.59 (KJ/cycle)

Cycle 78 GMT 28/11/2018 16:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 26 14.54 440 166 0.17 / 357.60 3 3
2 12 1120.32 4 9.89 1816 72 0.24 / 357.67 3 3
3 12 2012.72 36 10.91 2973 1168 1.41 / 358.84 3 3
4 7 2010.16 24 11.73 3076 866 2.27 / 359.71 3 3
5 13 1600.68 32 12.89 2566 1058 3.33 / 360.76 3 5
6 13 711.20 32 13.64 1347 588 3.92 / 361.35 3 5
7 13 61.20 32 14.39 410 189 4.11 / 361.54 3 5
8 8 -0.08 150 14.39 306 661 4.77 / 362.20 3 9
Average= 4.58 (KJ/cycle)

Cycle 77 GMT 18/11/2018 15:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 26 14.57 426 161 0.16 / 352.76 3 3
2 12 1120.12 4 9.82 1833 72 0.23 / 352.83 3 3
3 12 1999.52 36 10.80 3010 1170 1.40 / 354.00 3 3
4 7 1996.68 25 11.76 3036 893 2.30 / 354.90 3 3
5 13 1567.88 32 12.93 2505 1036 3.33 / 355.93 2 4
6 13 818.40 32 13.55 1492 647 3.98 / 356.58 3 7
7 13 72.08 32 14.36 429 197 4.18 / 356.78 3 5
8 8 -0.08 150 14.39 304 656 4.83 / 357.43 3 10
Average= 4.58 (KJ/cycle)

Cycle 76 GMT 8/11/2018 14:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 26 14.55 431 163 0.16 / 347.87 3 3
2 12 1119.40 4 9.90 1835 73 0.24 / 347.94 3 3
3 12 2002.08 36 10.83 3013 1175 1.41 / 349.11 3 3
4 7 1999.24 24 11.75 3032 855 2.27 / 349.97 3 3
5 13 1597.00 32 12.93 2537 1050 3.32 / 351.02 3 4
6 13 715.40 32 13.65 1348 589 3.90 / 351.61 3 5
7 13 57.00 32 14.41 399 184 4.09 / 351.79 3 4
8 13 15.68 32 14.46 333 154 4.24 / 351.94 3 4
9 8 -0.12 150 14.36 305 657 4.90 / 352.60 3 8
Average= 4.58 (KJ/cycle)

Cycle 75 GMT 29/10/2018 13:46: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 26 14.53 444 168 0.17 / 343.15 3 3
2 12 1125.16 3 8.53 1808 46 0.21 / 343.19 3 3
3 12 2002.80 36 10.78 3018 1171 1.39 / 344.36 3 3
4 7 2000.32 24 11.75 3033 855 2.24 / 345.22 3 3
5 13 1604.16 32 12.91 2562 1058 3.30 / 346.28 3 4
6 13 717.84 32 13.65 1346 588 3.89 / 346.87 3 5
7 13 63.80 32 14.41 408 188 4.08 / 347.05 3 4
8 8 -0.08 150 14.41 300 648 4.72 / 347.70 3 6
Average= 4.58 (KJ/cycle)

Cycle 74 GMT 19/10/2018 13:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 26 14.56 436 165 0.17 / 338.43 3 3
2 12 1103.24 3 8.58 1759 45 0.21 / 338.48 3 3
3 12 2001.16 36 10.89 2973 1166 1.38 / 339.64 3 3
4 7 1998.12 24 11.75 3038 857 2.23 / 340.50 3 3
5 13 1589.32 32 12.93 2542 1052 3.28 / 341.55 3 4
6 13 668.04 32 13.70 1281 562 3.85 / 342.11 3 5
7 13 90.80 32 14.36 451 207 4.05 / 342.32 3 5
8 8 0.00 150 14.40 305 659 4.71 / 342.98 3 7
Average= 4.57 (KJ/cycle)

Cycle 73 GMT 9/10/2018 12:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 26 14.56 439 166 0.17 / 333.55 3 3
2 12 1117.56 3 9.03 1794 49 0.21 / 333.60 3 3
3 12 2000.32 36 10.90 3022 1186 1.40 / 334.78 3 3
4 7 1997.92 24 11.78 3074 869 2.27 / 335.65 3 3
5 13 1573.60 32 12.96 2513 1042 3.31 / 336.69 3 4
6 13 962.72 32 13.45 1691 728 4.04 / 337.42 3 5
7 13 78.28 32 14.40 428 197 4.24 / 337.62 3 4
8 8 -0.04 150 14.43 299 647 4.88 / 338.27 3 5
Average= 4.57 (KJ/cycle)

Cycle 72 GMT 29/ 9/2018 12:55: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 26 14.57 433 164 0.16 / 328.78 3 3
2 12 1118.24 3 9.36 1816 51 0.22 / 328.83 3 3
3 12 1999.68 36 10.97 2989 1180 1.40 / 330.01 3 3
4 7 1996.68 24 11.78 3065 867 2.26 / 330.88 3 3
5 13 1710.00 32 12.86 2679 1102 3.36 / 331.98 3 4
6 13 646.48 32 13.72 1248 548 3.91 / 332.53 3 5
7 13 83.28 32 14.38 440 202 4.11 / 332.73 3 4
8 8 0.08 150 14.43 301 652 4.77 / 333.38 3 7
Average= 4.57 (KJ/cycle)

Cycle 71 GMT 19/ 9/2018 12:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 26 14.58 441 167 0.17 / 323.89 3 3
2 12 1119.80 3 9.28 1803 50 0.22 / 323.94 3 3
3 12 2001.00 36 11.06 2983 1188 1.41 / 325.13 3 3
4 7 1998.56 24 11.75 3071 866 2.27 / 325.99 3 3
5 13 1584.08 32 12.95 2512 1041 3.31 / 327.03 3 3
6 13 967.72 32 13.46 1691 728 4.04 / 327.76 3 5
7 13 88.32 32 14.40 440 203 4.24 / 327.96 3 4
8 8 0.04 150 14.43 301 652 4.89 / 328.62 3 8
Average= 4.56 (KJ/cycle)

Cycle 70 GMT 9/ 9/2018 12:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 26 14.57 444 168 0.17 / 319.04 3 3
2 12 1108.96 3 9.53 1798 51 0.22 / 319.09 3 3
3 12 2002.68 36 11.08 2985 1191 1.41 / 320.28 3 3
4 7 1999.88 24 11.77 3095 874 2.28 / 321.15 3 3
5 13 1578.92 32 12.93 2531 1047 3.33 / 322.20 3 4
6 13 834.32 32 13.57 1502 652 3.98 / 322.85 3 5
7 13 96.20 32 14.39 456 210 4.19 / 323.06 3 4
8 8 0.04 150 14.43 305 660 4.85 / 323.72 3 9
Average= 4.56 (KJ/cycle)

Cycle 69 GMT 30/ 8/2018 11:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 26 14.58 443 168 0.17 / 314.31 3 3
2 7 2006.28 56 10.79 3018 1824 1.99 / 316.14 3 3
3 13 1624.64 52 12.56 2542 1660 3.65 / 317.80 2 3
4 13 157.32 52 14.23 551 408 4.06 / 318.20 3 5
5 8 -0.20 150 14.41 307 664 4.72 / 318.87 3 10
Average= 4.56 (KJ/cycle)

Cycle 68 GMT 20/ 8/2018 11:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 26 14.58 433 164 0.16 / 309.81 3 3
2 7 2002.68 56 10.79 3007 1817 1.98 / 311.62 3 3
3 13 1383.76 52 12.80 2258 1503 3.48 / 313.13 3 4
4 13 117.60 52 14.32 486 362 3.85 / 313.49 3 4
5 8 0.00 150 14.44 303 656 4.50 / 314.14 3 8
Average= 4.55 (KJ/cycle)

Cycle 67 GMT 10/ 8/2018 11:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 26 14.59 443 168 0.17 / 304.88 3 3
2 7 2006.56 56 10.85 3015 1832 2.00 / 306.71 3 3
3 13 1618.80 52 12.59 2571 1683 3.68 / 308.39 3 3
4 13 334.20 52 13.97 815 592 4.28 / 308.99 3 5
5 8 -0.08 150 14.41 304 657 4.93 / 309.64 3 10
Average= 4.55 (KJ/cycle)

Cycle 66 GMT 31/ 7/2018 11:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 26 14.57 458 173 0.17 / 300.21 3 3
2 7 2001.80 56 10.84 3028 1838 2.01 / 302.04 3 3
3 13 1494.88 52 12.71 2413 1595 3.61 / 303.64 3 4
4 13 161.64 52 14.24 558 413 4.02 / 304.05 3 5
5 8 0.04 150 14.43 304 658 4.68 / 304.71 3 4
Average= 4.55 (KJ/cycle)

Cycle 65 GMT 21/ 7/2018 11:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 26 14.58 446 169 0.17 / 295.32 3 3
2 7 2003.76 57 10.97 3009 1881 2.05 / 297.20 3 3
3 13 1611.48 52 12.62 2567 1685 3.74 / 298.88 3 3
4 13 228.12 52 14.12 661 485 4.22 / 299.37 3 5
5 8 -0.12 150 14.40 308 665 4.89 / 300.03 3 14
Average= 4.55 (KJ/cycle)

Cycle 64 GMT 11/ 7/2018 11:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 26 14.60 438 166 0.17 / 290.41 3 3
2 7 2005.60 56 11.06 3030 1877 2.04 / 292.29 3 3
3 13 1622.12 52 12.63 2586 1698 3.74 / 293.99 3 3
4 13 224.96 52 14.13 657 483 4.22 / 294.47 3 6
5 8 -0.12 150 14.40 312 674 4.90 / 295.15 3 8
Average= 4.54 (KJ/cycle)

Cycle 63 GMT 1/ 7/2018 11:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 26 14.60 443 168 0.17 / 285.48 3 3
2 7 2002.68 57 11.12 3045 1930 2.10 / 287.41 3 3
3 13 1607.96 52 12.65 2543 1673 3.77 / 289.09 3 3
4 13 227.28 52 14.13 664 488 4.26 / 289.57 3 6
5 8 -0.12 150 14.40 312 674 4.93 / 290.25 3 10
Average= 4.54 (KJ/cycle)

Cycle 62 GMT 21/ 6/2018 11:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 26 14.59 451 171 0.17 / 280.71 3 3
2 7 2008.80 57 11.22 3053 1953 2.12 / 282.66 3 3
3 13 1502.12 52 12.76 2425 1609 3.73 / 284.27 3 3
4 13 131.80 52 14.29 517 384 4.12 / 284.65 3 5
5 8 -0.08 150 14.42 307 664 4.78 / 285.32 3 9
Average= 4.53 (KJ/cycle)

Cycle 61 GMT 11/ 6/2018 10:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 26 14.60 444 169 0.17 / 276.04 3 3
2 7 2004.32 56 11.08 3044 1889 2.06 / 277.93 3 3
3 13 1391.12 52 12.89 2270 1522 3.58 / 279.45 3 3
4 13 175.36 52 14.23 574 425 4.00 / 279.87 3 5
5 8 0.04 150 14.41 307 664 4.67 / 280.53 3 10
Average= 4.52 (KJ/cycle)

Cycle 60 GMT 1/ 6/2018 10:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 26 14.59 451 171 0.17 / 271.21 3 3
2 7 2003.80 46 11.26 3043 1576 1.75 / 272.79 3 3
3 13 1882.20 32 12.72 2930 1193 2.94 / 273.98 3 3
4 13 1000.88 32 13.49 1741 752 3.69 / 274.73 3 4
5 13 226.16 32 14.22 663 302 3.99 / 275.03 3 5
6 13 38.80 32 14.46 371 172 4.16 / 275.20 3 5
7 8 -0.08 150 14.36 308 663 4.83 / 275.87 3 9
Average= 4.52 (KJ/cycle)

Cycle 59 GMT 22/ 5/2018 10:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 26 14.61 435 165 0.17 / 266.24 3 3
2 7 2002.00 46 11.28 3050 1583 1.75 / 267.82 3 3
3 13 1877.12 32 12.74 2928 1194 2.94 / 269.02 3 3
4 13 1278.08 32 13.30 2130 907 3.85 / 269.92 3 3
5 13 188.44 32 14.27 606 277 4.12 / 270.20 3 5
6 13 40.56 32 14.46 377 174 4.30 / 270.38 3 4
7 8 0.00 150 14.37 308 664 4.96 / 271.04 3 9
Average= 4.52 (KJ/cycle)

Cycle 58 GMT 12/ 5/2018 10:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 26 14.61 436 166 0.17 / 261.34 3 3
2 7 2004.84 45 11.43 3067 1578 1.74 / 262.92 3 3
3 13 1890.28 32 12.74 2930 1195 2.94 / 264.11 3 3
4 13 1145.92 32 13.41 1941 833 3.77 / 264.94 3 4
5 13 208.04 32 14.24 633 288 4.06 / 265.23 3 5
6 13 43.12 32 14.46 379 175 4.23 / 265.41 3 5
7 8 -0.12 150 14.36 310 668 4.90 / 266.08 3 10
Average= 4.51 (KJ/cycle)

Cycle 57 GMT 2/ 5/2018 10:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 26 14.62 441 168 0.17 / 256.58 3 3
2 7 2002.40 46 11.48 3074 1623 1.79 / 258.20 3 3
3 13 1750.40 32 12.92 2768 1144 2.94 / 259.35 3 3
4 13 1017.88 32 13.52 1766 764 3.70 / 260.11 3 4
5 13 123.08 32 14.35 507 233 3.93 / 260.34 3 4
6 13 28.20 32 14.47 356 165 4.10 / 260.51 3 5
7 8 -0.08 150 14.36 309 666 4.76 / 261.17 3 8
Average= 4.50 (KJ/cycle)

Cycle 56 GMT 22/ 4/2018 10:19: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 26 14.63 431 164 0.16 / 251.82 3 3
2 7 2002.48 45 11.56 3045 1584 1.75 / 253.40 3 3
3 13 1875.00 32 12.79 2921 1196 2.94 / 254.60 3 3
4 13 985.48 32 13.54 1725 747 3.69 / 255.35 3 4
5 13 114.12 32 14.36 496 228 3.92 / 255.57 3 5
6 13 28.52 32 14.46 362 168 4.09 / 255.74 3 5
7 8 -0.24 150 14.35 311 669 4.76 / 256.41 3 10
Average= 4.50 (KJ/cycle)

Cycle 55 GMT 12/ 4/2018 10:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 26 14.60 432 164 0.16 / 247.05 3 3
2 7 2002.16 46 11.70 3034 1633 1.80 / 248.69 3 3
3 13 1872.64 32 12.81 2916 1195 2.99 / 249.88 3 3
4 13 976.60 32 13.56 1705 740 3.73 / 250.62 3 4
5 13 107.32 32 14.38 476 219 3.95 / 250.84 3 4
6 13 27.40 32 14.49 346 160 4.11 / 251.00 3 4
7 8 -0.04 150 14.37 304 655 4.77 / 251.66 3 11
Average= 4.49 (KJ/cycle)

Cycle 54 GMT 2/ 4/2018 10: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 26 14.63 434 165 0.17 / 242.25 3 3
2 7 2011.44 45 11.69 3070 1615 1.78 / 243.87 3 3
3 13 1888.72 32 12.82 2913 1195 2.98 / 245.06 3 3
4 13 986.36 32 13.57 1713 744 3.72 / 245.81 3 4
5 13 199.92 32 14.25 621 283 4.00 / 246.09 3 5
6 13 19.92 32 14.50 335 155 4.16 / 246.25 3 5
7 8 -0.04 150 14.38 298 643 4.80 / 246.89 3 8
Average= 4.49 (KJ/cycle)

Cycle 53 GMT 23/ 3/2018 9:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 26 14.63 436 166 0.17 / 237.37 3 3
2 7 2005.92 45 11.86 3050 1628 1.79 / 239.00 3 3
3 13 1878.44 32 12.84 2911 1196 2.99 / 240.20 3 3
4 13 1104.92 32 13.49 1886 814 3.80 / 241.01 3 4
5 13 154.16 32 14.31 556 255 4.06 / 241.27 3 5
6 13 33.88 32 14.47 359 166 4.22 / 241.43 3 5
7 8 -0.16 150 14.37 304 655 4.88 / 242.09 3 11
Average= 4.48 (KJ/cycle)

Cycle 52 GMT 13/ 3/2018 9:19: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 26 14.65 426 162 0.16 / 232.62 3 3
2 7 2008.00 46 11.90 3074 1683 1.84 / 234.30 3 3
3 13 1882.88 32 12.84 2934 1206 3.05 / 235.51 3 3
4 13 844.60 32 13.68 1524 667 3.72 / 236.17 3 4
5 13 119.84 32 14.36 497 228 3.95 / 236.40 3 5
6 13 13.00 32 14.50 326 151 4.10 / 236.55 3 4
7 8 -0.12 150 14.35 305 657 4.75 / 237.21 3 10
Average= 4.48 (KJ/cycle)

Cycle 51 GMT 3/ 3/2018 9:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 26 14.65 430 164 0.16 / 228.00 3 3
2 7 2002.20 45 11.98 3056 1647 1.81 / 229.65 3 3
3 13 1619.52 32 13.12 2571 1079 2.89 / 230.73 3 3
4 13 899.08 32 13.65 1596 697 3.59 / 231.42 3 4
5 13 122.24 32 14.36 500 230 3.82 / 231.65 3 5
6 13 13.20 32 14.51 325 151 3.97 / 231.80 3 4
7 8 -0.12 150 14.36 302 651 4.62 / 232.46 3 10
Average= 4.47 (KJ/cycle)

Cycle 50 GMT 21/ 2/2018 8:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 26 14.66 438 167 0.17 / 223.07 3 3
2 7 2005.68 46 12.12 3065 1709 1.88 / 224.78 3 3
3 13 1876.24 32 12.89 2907 1199 3.07 / 225.97 3 3
4 13 1100.28 32 13.52 1857 803 3.88 / 226.78 3 4
5 13 151.68 32 14.33 543 249 4.13 / 227.03 3 5
6 13 35.08 32 14.49 358 166 4.29 / 227.19 3 4
7 8 -0.12 150 14.39 298 643 4.94 / 227.84 3 8
Average= 4.47 (KJ/cycle)

Cycle 49 GMT 11/ 2/2018 8:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 26 14.67 436 166 0.17 / 218.35 3 3
2 7 2002.08 45 12.23 3062 1685 1.85 / 220.04 3 3
3 13 1744.36 32 13.07 2738 1145 3.00 / 221.18 3 3
4 13 858.96 32 13.70 1546 678 3.67 / 221.86 3 4
5 13 114.52 32 14.38 489 225 3.90 / 222.08 3 5
6 13 28.32 32 14.49 349 162 4.06 / 222.25 3 4
7 8 0.04 150 14.39 303 654 4.72 / 222.90 3 11
Average= 4.46 (KJ/cycle)

Cycle 48 GMT 1/ 2/2018 8:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 26 14.67 446 170 0.17 / 213.56 3 3
2 7 2004.80 46 12.37 3054 1738 1.91 / 215.30 3 3
3 13 1873.68 32 12.95 2891 1198 3.11 / 216.50 3 3
4 13 815.32 32 13.73 1485 652 3.76 / 217.15 3 4
5 13 111.80 32 14.40 483 223 3.98 / 217.37 3 4
6 13 30.00 32 14.50 350 162 4.14 / 217.54 3 4
7 8 -0.16 150 14.40 300 648 4.79 / 218.18 3 8
Average= 4.45 (KJ/cycle)

Cycle 47 GMT 22/ 1/2018 8:30: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 26 14.70 442 169 0.17 / 208.71 3 3
2 7 2004.40 46 12.48 3055 1754 1.92 / 210.46 3 3
3 13 1735.44 32 13.11 2722 1142 3.06 / 211.61 3 3
4 13 976.52 32 13.63 1700 741 3.81 / 212.35 3 4
5 13 109.76 32 14.41 477 220 4.03 / 212.57 3 4
6 13 56.84 32 14.46 386 179 4.20 / 212.75 3 4
7 8 -0.08 150 14.41 299 646 4.85 / 213.39 3 8
Average= 4.45 (KJ/cycle)

Cycle 46 GMT 12/ 1/2018 8:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 26 14.69 451 172 0.17 / 203.96 3 3
2 7 2003.64 45 12.55 3088 1744 1.92 / 205.71 3 3
3 13 1730.64 32 13.13 2725 1145 3.06 / 206.85 3 3
4 13 840.24 32 13.73 1516 666 3.73 / 207.52 3 4
5 13 122.56 32 14.40 490 226 3.95 / 207.74 3 4
6 13 31.00 32 14.53 344 160 4.11 / 207.90 3 3
7 8 -0.04 150 14.44 295 639 4.75 / 208.54 3 8
Average= 4.44 (KJ/cycle)

Cycle 45 GMT 2/ 1/2018 8:10: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 26 14.70 441 169 0.17 / 199.20 3 3
2 7 2003.04 45 12.62 3076 1747 1.92 / 200.95 3 3
3 13 1739.68 32 13.13 2745 1153 3.07 / 202.10 3 3
4 13 840.96 32 13.73 1519 667 3.74 / 202.77 3 4
5 13 128.84 32 14.41 499 230 3.97 / 203.00 3 4
6 13 30.32 32 14.55 338 157 4.12 / 203.16 3 4
7 8 -0.08 150 14.45 293 635 4.76 / 203.79 3 6
Average= 4.43 (KJ/cycle)

Cycle 44 GMT 23/12/2017 7:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 26 14.71 426 163 0.16 / 194.34 3 3
2 7 2004.64 49 12.64 3091 1914 2.08 / 196.25 3 3
3 13 1740.92 31 13.15 2755 1123 3.20 / 197.38 3 3
4 13 832.68 31 13.75 1501 640 3.84 / 198.02 3 4
5 13 126.52 31 14.42 497 222 4.06 / 198.24 3 4
6 13 30.08 31 14.56 338 153 4.21 / 198.39 3 4
7 8 -0.20 150 14.46 295 640 4.85 / 199.03 3 5
Average= 4.42 (KJ/cycle)

Cycle 43 GMT 13/12/2017 7:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 26 14.68 455 174 0.17 / 189.94 3 3
2 7 2001.28 49 12.73 3043 1898 2.07 / 191.84 3 3
3 13 1455.48 31 13.34 2345 970 3.04 / 192.81 3 3
4 13 593.52 31 13.93 1185 512 3.55 / 193.32 3 5
5 13 106.04 31 14.47 461 207 3.76 / 193.53 3 4
6 8 0.08 150 14.50 298 648 4.41 / 194.18 3 8
Average= 4.41 (KJ/cycle)

Cycle 42 GMT 3/12/2017 6:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 26 14.69 451 172 0.17 / 185.30 3 3
2 7 2004.24 49 12.76 3060 1913 2.09 / 187.22 3 3
3 13 1593.76 31 13.28 2522 1038 3.12 / 188.26 3 3
4 13 841.24 31 13.75 1517 647 3.77 / 188.90 3 5
5 13 119.32 31 14.43 487 218 3.99 / 189.12 3 4
6 8 0.12 150 14.47 299 649 4.64 / 189.77 3 7
Average= 4.41 (KJ/cycle)

Cycle 41 GMT 23/11/2017 6:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 26 14.69 456 174 0.17 / 180.89 3 3
2 7 2003.40 48 12.81 3048 1874 2.05 / 182.77 3 3
3 13 1461.72 31 13.35 2371 981 3.03 / 183.75 3 3
4 13 618.68 31 13.93 1221 527 3.56 / 184.28 3 5
5 13 98.72 31 14.46 461 207 3.76 / 184.48 3 4
6 8 -0.04 150 14.49 298 648 4.41 / 185.13 3 7
Average= 4.41 (KJ/cycle)

Cycle 40 GMT 13/11/2017 5:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 26 14.67 447 170 0.17 / 176.35 3 3
2 7 2003.24 48 12.85 3060 1887 2.06 / 178.23 3 3
3 13 1593.00 31 13.30 2525 1041 3.10 / 179.27 3 3
4 13 701.92 31 13.87 1329 571 3.67 / 179.85 3 5
5 13 115.08 31 14.43 486 217 3.89 / 180.06 3 4
6 8 0.08 150 14.46 303 657 4.54 / 180.72 3 5
Average= 4.41 (KJ/cycle)

Cycle 39 GMT 3/11/2017 5:26: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 26 14.70 439 168 0.17 / 171.61 3 3
2 7 2007.00 48 12.86 3048 1881 2.05 / 173.49 3 3
3 13 1604.60 31 13.29 2559 1054 3.10 / 174.54 3 3
4 13 731.48 31 13.85 1368 587 3.69 / 175.13 3 4
5 13 118.36 31 14.43 492 220 3.91 / 175.35 3 4
6 13 59.32 31 14.49 396 178 4.09 / 175.53 3 4
7 8 -0.20 150 14.44 299 648 4.74 / 176.18 3 7
Average= 4.40 (KJ/cycle)

Cycle 38 GMT 24/10/2017 4:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 26 14.70 444 170 0.17 / 166.91 3 3
2 7 2003.24 49 12.85 3093 1948 2.12 / 168.85 3 3
3 13 1462.88 31 13.38 2371 983 3.10 / 169.84 3 3
4 13 727.00 31 13.87 1363 586 3.69 / 170.42 3 4
5 13 80.96 31 14.50 434 195 3.88 / 170.62 3 4
6 13 40.56 31 14.51 367 165 4.05 / 170.78 3 4
7 8 -0.04 150 14.44 302 654 4.70 / 171.44 3 7
Average= 4.40 (KJ/cycle)

Cycle 37 GMT 14/10/2017 4:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 26 14.72 439 168 0.17 / 162.13 3 3
2 7 2001.32 49 12.89 3065 1936 2.10 / 164.07 3 3
3 13 1724.36 31 13.26 2702 1111 3.21 / 165.18 3 3
4 13 954.24 31 13.72 1670 710 3.92 / 165.89 3 4
5 13 89.64 31 14.49 443 199 4.12 / 166.09 3 4
6 8 -0.04 150 14.50 299 650 4.77 / 166.74 3 6
Average= 4.39 (KJ/cycle)

Cycle 36 GMT 4/10/2017 4:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 26 14.69 434 166 0.17 / 157.56 3 3
2 7 2003.16 48 12.91 3070 1902 2.07 / 159.46 3 3
3 13 1595.44 31 13.34 2533 1047 3.12 / 160.51 3 3
4 13 718.72 31 13.89 1356 584 3.70 / 161.09 3 4
5 13 112.84 31 14.46 485 217 3.92 / 161.31 3 4
6 8 0.04 150 14.49 301 654 4.57 / 161.96 3 7
Average= 4.38 (KJ/cycle)

Cycle 35 GMT 24/ 9/2017 4: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 26 14.70 443 169 0.17 / 152.98 3 3
2 7 2003.60 49 12.92 3078 1949 2.12 / 154.93 3 3
3 13 1482.12 31 13.40 2403 998 3.12 / 155.93 3 3
4 13 727.12 31 13.89 1369 589 3.71 / 156.52 3 5
5 13 115.60 31 14.45 490 219 3.93 / 156.74 3 4
6 8 -0.04 150 14.45 303 657 4.58 / 157.39 3 8
Average= 4.37 (KJ/cycle)

Cycle 34 GMT 14/ 9/2017 3:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 26 14.69 443 169 0.17 / 148.44 3 3
2 7 2006.96 48 12.93 3092 1919 2.09 / 150.36 3 3
3 13 1485.12 31 13.40 2413 1002 3.09 / 151.36 3 3
4 13 748.28 31 13.88 1386 596 3.69 / 151.96 3 4
5 13 85.24 31 14.50 437 196 3.88 / 152.16 3 4
6 8 -0.08 150 14.46 301 653 4.54 / 152.81 3 4
Average= 4.37 (KJ/cycle)

Cycle 33 GMT 4/ 9/2017 3: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 26 14.71 452 173 0.17 / 143.86 3 3
2 7 2002.04 48 12.95 3086 1918 2.09 / 145.78 3 3
3 13 1577.60 31 13.37 2511 1041 3.13 / 146.82 3 3
4 13 698.32 31 13.92 1327 573 3.70 / 147.39 3 4
5 13 99.72 31 14.47 474 213 3.92 / 147.60 3 4
6 8 -0.16 150 14.46 309 670 4.59 / 148.27 3 5
Average= 4.36 (KJ/cycle)

Cycle 32 GMT 25/ 8/2017 2:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 26 14.69 443 169 0.17 / 139.19 3 3
2 7 2004.44 49 12.94 3068 1945 2.11 / 141.13 3 3
3 13 1592.12 31 13.35 2556 1058 3.17 / 142.19 2 3
4 13 563.12 31 14.02 1141 496 3.67 / 142.69 3 4
5 13 76.24 31 14.52 429 193 3.86 / 142.88 3 4
6 13 21.80 31 14.57 340 154 4.01 / 143.03 3 4
7 8 0.12 150 14.44 302 654 4.67 / 143.69 3 9
Average= 4.35 (KJ/cycle)

Cycle 31 GMT 15/ 8/2017 2:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 25 14.67 447 164 0.16 / 134.64 3 3
2 7 2001.76 48 12.94 3064 1903 2.07 / 136.54 3 3
3 13 1590.56 31 13.35 2535 1049 3.12 / 137.59 3 3
4 13 660.72 31 13.96 1268 549 3.66 / 138.14 3 4
5 13 83.96 31 14.49 448 201 3.87 / 138.34 3 4
6 8 -0.04 150 14.45 311 674 4.54 / 139.02 3 9
Average= 4.34 (KJ/cycle)

Cycle 30 GMT 5/ 8/2017 2: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 26 14.68 443 169 0.17 / 129.99 3 3
2 7 2001.48 49 12.94 3037 1926 2.09 / 131.92 3 3
3 13 1585.28 31 13.35 2529 1047 3.14 / 132.96 3 3
4 13 828.08 31 13.83 1503 644 3.79 / 133.61 3 4
5 13 87.12 31 14.50 451 203 3.99 / 133.81 3 4
6 8 0.00 150 14.44 308 667 4.66 / 134.48 3 6
Average= 4.34 (KJ/cycle)

Cycle 29 GMT 26/ 7/2017 1:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 25 14.66 450 165 0.16 / 125.47 3 3
2 7 2004.92 49 12.92 3081 1951 2.12 / 127.42 3 3
3 13 1449.20 31 13.43 2353 980 3.10 / 128.40 3 3
4 13 706.20 31 13.93 1334 576 3.67 / 128.97 3 4
5 13 62.12 31 14.54 408 184 3.86 / 129.16 3 4
6 8 0.20 150 14.44 307 665 4.52 / 129.82 3 4
Average= 4.33 (KJ/cycle)

Cycle 28 GMT 16/ 7/2017 1:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 25 14.67 440 161 0.16 / 120.86 3 3
2 7 2002.24 49 12.92 3053 1933 2.09 / 122.79 3 3
3 13 1442.28 31 13.44 2338 974 3.07 / 123.77 3 3
4 13 848.92 31 13.83 1529 656 3.72 / 124.42 3 4
5 13 86.16 31 14.51 451 203 3.93 / 124.63 3 4
6 8 -0.12 150 14.42 312 675 4.60 / 125.30 3 6
Average= 4.32 (KJ/cycle)

Cycle 27 GMT 6/ 7/2017 1: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 25 14.66 445 163 0.16 / 116.30 3 3
2 7 2004.56 48 12.89 3066 1897 2.06 / 118.20 3 3
3 13 1596.32 31 13.34 2548 1054 3.11 / 119.26 3 3
4 13 707.40 31 13.93 1343 580 3.69 / 119.84 3 4
5 13 57.84 31 14.54 412 186 3.88 / 120.02 3 4
6 8 0.04 150 14.42 314 679 4.56 / 120.70 3 6
Average= 4.31 (KJ/cycle)

Cycle 26 GMT 26/ 6/2017 1:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 25 14.70 452 166 0.17 / 111.63 3 3
2 7 2003.08 48 12.88 3036 1877 2.04 / 113.51 3 3
3 13 1723.60 31 13.25 2736 1124 3.17 / 114.63 3 3
4 13 802.80 31 13.86 1470 632 3.80 / 115.26 3 4
5 13 79.40 31 14.51 446 201 4.00 / 115.46 3 4
6 8 -0.20 150 14.42 314 679 4.68 / 116.14 3 8
Average= 4.30 (KJ/cycle)

Cycle 25 GMT 16/ 6/2017 1: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 25 14.70 447 164 0.16 / 107.03 3 3
2 7 2004.92 48 12.82 3067 1887 2.05 / 108.91 3 3
3 13 1477.28 31 13.39 2378 987 3.04 / 109.90 3 3
4 13 605.88 31 14.01 1196 519 3.56 / 110.42 3 4
5 13 69.32 31 14.54 431 194 3.75 / 110.61 3 4
6 13 35.08 31 14.53 374 168 3.92 / 110.78 3 4
7 8 -0.12 150 14.42 315 681 4.60 / 111.46 3 10
Average= 4.29 (KJ/cycle)

Cycle 24 GMT 6/ 6/2017 0:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 25 14.68 455 167 0.17 / 102.50 3 3
2 7 2002.20 48 12.79 3064 1881 2.05 / 104.38 3 3
3 13 1577.36 31 13.32 2527 1043 3.09 / 105.43 3 3
4 13 682.28 31 13.95 1312 567 3.66 / 106.00 3 4
5 13 61.16 31 14.56 416 188 3.85 / 106.18 3 4
6 8 -0.04 150 14.44 313 678 4.52 / 106.86 3 7
Average= 4.27 (KJ/cycle)

Cycle 23 GMT 26/ 5/2017 23:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 25 14.71 450 165 0.17 / 97.86 3 3
2 7 2003.44 49 12.81 3026 1899 2.06 / 99.76 3 3
3 13 1584.12 31 13.33 2537 1048 3.11 / 100.81 2 3
4 13 829.16 31 13.84 1509 647 3.76 / 101.46 3 4
5 13 86.36 31 14.53 453 204 3.96 / 101.66 3 4
6 8 -0.24 150 14.43 311 673 4.64 / 102.34 3 9
Average= 4.26 (KJ/cycle)

Cycle 22 GMT 16/ 5/2017 23:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 25 14.70 451 166 0.17 / 93.32 3 3
2 7 2002.28 49 12.81 3087 1938 2.10 / 95.26 3 3
3 13 1450.60 31 13.42 2351 978 3.08 / 96.24 3 3
4 13 700.84 31 13.95 1332 576 3.66 / 96.81 3 5
5 13 99.76 31 14.52 475 214 3.87 / 97.03 3 5
6 8 0.00 150 14.48 309 671 4.54 / 97.70 3 7
Average= 4.25 (KJ/cycle)

Cycle 21 GMT 6/ 5/2017 23: 6: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 25 14.75 444 164 0.16 / 88.78 3 3
2 7 2002.56 48 12.83 3057 1883 2.05 / 90.66 3 3
3 13 1581.76 31 13.36 2510 1040 3.09 / 91.70 3 3
4 13 693.72 31 13.96 1314 569 3.65 / 92.27 3 4
5 13 107.40 31 14.51 482 217 3.87 / 92.49 3 4
6 8 -0.16 150 14.49 307 667 4.54 / 93.16 3 6
Average= 4.23 (KJ/cycle)

Cycle 20 GMT 26/ 4/2017 22:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 25 14.76 434 160 0.16 / 84.18 3 3
2 7 2005.20 48 12.84 3063 1888 2.05 / 86.07 3 3
3 13 1468.32 31 13.42 2371 986 3.03 / 87.05 3 3
4 13 589.64 31 14.05 1178 513 3.55 / 87.57 3 4
5 13 66.32 31 14.57 422 191 3.74 / 87.76 3 4
6 8 -0.28 190 14.41 314 860 4.60 / 88.62 3 11
Average= 4.22 (KJ/cycle)

Cycle 19 GMT 16/ 4/2017 21:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 25 14.77 441 163 0.16 / 79.41 3 3
2 7 2008.96 49 12.85 3070 1933 2.10 / 81.35 3 3
3 13 1613.20 31 13.34 2561 1059 3.15 / 82.40 3 3
4 13 710.76 31 13.95 1348 583 3.74 / 82.99 3 4
5 13 59.60 31 14.59 410 185 3.92 / 83.17 3 4
6 8 -0.32 190 14.43 309 847 4.77 / 84.02 3 13
Average= 4.20 (KJ/cycle)

Cycle 18 GMT 6/ 4/2017 20:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 25 14.78 449 166 0.17 / 74.51 3 3
2 7 2006.12 48 12.87 3061 1891 2.06 / 76.41 3 3
3 13 1600.92 31 13.36 2542 1053 3.11 / 77.46 3 3
4 13 693.28 31 13.97 1322 573 3.68 / 78.03 3 4
5 13 97.28 31 14.53 471 212 3.89 / 78.24 3 4
6 13 21.40 31 14.61 347 157 4.05 / 78.40 3 4
7 8 -0.24 190 14.42 310 849 4.90 / 79.25 3 20
Average= 4.17 (KJ/cycle)

Cycle 17 GMT 27/ 3/2017 19: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 25 14.79 445 165 0.16 / 69.75 3 3
2 7 2001.48 48 12.89 3064 1896 2.06 / 71.64 3 3
3 13 1596.88 31 13.36 2559 1060 3.12 / 72.70 3 3
4 13 704.16 31 13.98 1335 579 3.70 / 73.28 3 4
5 13 104.88 31 14.54 484 218 3.92 / 73.50 3 4
6 8 -0.20 190 14.47 309 850 4.77 / 74.35 3 11
Average= 4.13 (KJ/cycle)

Cycle 16 GMT 17/ 3/2017 18: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 25 14.80 442 164 0.16 / 65.30 3 3
2 7 2000.84 45 12.93 3087 1796 1.96 / 67.09 3 3
3 13 1470.60 29 13.47 2386 932 2.89 / 68.03 3 3
4 13 638.56 29 14.05 1251 510 3.40 / 68.54 3 4
5 13 92.92 29 14.58 465 197 3.60 / 68.73 3 4
6 8 -0.12 190 14.48 309 850 4.45 / 69.58 3 10
Average= 4.09 (KJ/cycle)

Cycle 15 GMT 7/ 3/2017 17:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 25 14.79 447 165 0.17 / 60.84 3 3
2 7 2001.20 45 12.96 3057 1783 1.95 / 62.62 3 3
3 13 1373.20 29 13.52 2259 886 2.83 / 63.50 3 3
4 13 811.36 29 13.93 1475 596 3.43 / 64.10 3 4
5 13 95.84 29 14.57 467 197 3.63 / 64.30 3 4
6 8 -0.04 190 14.48 304 836 4.46 / 65.13 3 8
Average= 4.07 (KJ/cycle)

Cycle 14 GMT 25/ 2/2017 16:17: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 25 14.81 450 167 0.17 / 56.33 3 3
2 7 2002.96 45 12.93 3066 1784 1.95 / 58.12 3 3
3 13 1375.56 29 13.53 2263 888 2.84 / 59.01 3 3
4 13 579.28 29 14.10 1174 480 3.32 / 59.49 3 4
5 13 74.44 29 14.61 436 185 3.50 / 59.67 3 4
6 13 38.00 29 14.61 373 158 3.66 / 59.83 3 4
7 8 -0.28 190 14.45 307 843 4.50 / 60.67 3 9
Average= 4.04 (KJ/cycle)

Cycle 13 GMT 15/ 2/2017 14:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 25 14.80 443 164 0.16 / 51.98 3 3
2 7 1998.76 45 12.95 3062 1784 1.95 / 53.76 3 3
3 13 1468.68 29 13.48 2385 932 2.88 / 54.70 2 3
4 13 525.44 29 14.15 1097 450 3.33 / 55.15 3 4
5 13 86.76 29 14.62 443 188 3.52 / 55.33 3 3
6 8 0.00 190 14.52 302 833 4.35 / 56.17 3 7
Average= 4.01 (KJ/cycle)

Cycle 12 GMT 5/ 2/2017 12:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 25 14.84 440 163 0.16 / 47.49 3 3
2 7 1994.08 46 12.97 3053 1821 1.98 / 49.31 3 3
3 13 1584.80 29 13.42 2538 988 2.97 / 50.30 2 3
4 13 595.36 29 14.09 1197 489 3.46 / 50.79 3 4
5 13 93.52 29 14.61 459 194 3.66 / 50.98 3 3
6 8 -0.12 190 14.51 302 833 4.49 / 51.81 3 6
Average= 3.99 (KJ/cycle)

Cycle 11 GMT 26/ 1/2017 10:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 25 14.80 450 166 0.17 / 42.86 3 3
2 7 2001.52 46 12.99 3067 1833 2.00 / 44.69 3 3
3 13 1489.48 29 13.48 2411 943 2.94 / 45.63 3 3
4 13 633.92 29 14.07 1249 510 3.45 / 46.14 3 4
5 13 92.24 29 14.61 460 195 3.65 / 46.34 3 4
6 13 22.36 29 14.69 344 147 3.79 / 46.48 3 4
7 8 -0.28 190 14.46 307 843 4.64 / 47.33 3 8
Average= 3.94 (KJ/cycle)

Cycle 10 GMT 16/ 1/2017 9:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 24 14.82 446 159 0.16 / 38.38 3 3
2 7 2002.28 45 13.00 3060 1790 1.95 / 40.17 3 3
3 13 1505.88 29 13.47 2441 954 2.90 / 41.13 3 3
4 13 644.20 29 14.06 1262 515 3.42 / 41.64 3 4
5 13 92.80 29 14.61 458 194 3.61 / 41.84 3 4
6 8 -0.16 190 14.49 310 853 4.46 / 42.69 3 10
Average= 3.88 (KJ/cycle)

Cycle 9 GMT 6/ 1/2017 8:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 24 14.83 442 157 0.16 / 34.03 3 3
2 7 1995.44 45 12.99 3065 1792 1.95 / 35.83 3 3
3 13 1479.32 29 13.49 2388 934 2.88 / 36.76 2 3
4 13 532.48 29 14.15 1107 454 3.34 / 37.21 3 4
5 13 77.56 29 14.65 429 182 3.52 / 37.40 3 3
6 8 -0.24 190 14.49 301 829 4.35 / 38.23 3 7
Average= 3.82 (KJ/cycle)

Cycle 8 GMT 27/12/2016 6:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 24 14.82 441 157 0.16 / 29.48 3 3
2 7 1989.52 46 13.00 3054 1826 1.98 / 31.31 3 3
3 13 1587.04 29 13.43 2532 986 2.97 / 32.29 3 3
4 13 727.60 29 14.00 1373 557 3.53 / 32.85 3 4
5 13 80.84 29 14.64 438 186 3.71 / 33.04 3 3
6 8 -0.12 190 14.49 305 840 4.55 / 33.88 3 7
Average= 3.76 (KJ/cycle)

Cycle 7 GMT 17/12/2016 4:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 24 14.83 445 158 0.16 / 25.13 3 3
2 7 1980.72 45 13.00 3037 1777 1.94 / 26.91 3 3
3 13 1469.76 29 13.48 2390 934 2.87 / 27.84 3 3
4 13 508.68 29 14.16 1075 441 3.31 / 28.28 3 4
5 13 101.16 29 14.59 473 200 3.51 / 28.48 3 4
6 8 -0.32 190 14.46 306 841 4.35 / 29.33 3 9
Average= 3.67 (KJ/cycle)

Cycle 6 GMT 7/12/2016 2:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 23 14.82 437 149 0.15 / 20.70 3 3
2 10 1013.60 3 14.63 1770 78 0.23 / 20.78 3 3
3 3 945.24 -1 15.56 0 0 0.08 / 20.78 3 3
4 7 1972.32 46 13.01 3019 1807 2.03 / 22.58 3 3
5 13 1445.12 29 13.48 2358 922 2.96 / 23.50 3 3
6 13 492.32 29 14.17 1051 432 3.39 / 23.94 3 4
7 13 94.00 29 14.59 468 198 3.59 / 24.13 3 4
8 8 -0.16 190 14.48 305 839 4.42 / 24.97 3 9
Average= 3.57 (KJ/cycle)

Cycle 5 GMT 27/11/2016 1:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 24 14.84 430 153 0.15 / 16.24 3 3
2 3 961.36 -1 15.57 0 0 0.00 / 16.24 3 3
3 7 1972.84 45 13.04 3002 1762 1.91 / 18.01 3 3
4 13 1584.40 29 13.39 2522 979 2.89 / 18.98 3 3
5 13 715.76 29 13.97 1359 551 3.44 / 19.54 3 4
6 13 69.56 29 14.64 422 179 3.62 / 19.71 3 4
7 8 -0.24 190 14.45 304 835 4.46 / 20.55 3 8
Average= 3.42 (KJ/cycle)

Cycle 4 GMT 16/11/2016 23:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 23 14.81 451 154 0.15 / 12.55 3 3
2 7 1508.84 45 13.41 2413 1456 1.61 / 14.00 3 3
3 13 1148.28 29 13.66 1937 767 2.38 / 14.77 3 3
4 13 312.28 29 14.33 791 329 2.71 / 15.10 3 4
5 13 45.44 29 14.69 380 162 2.87 / 15.26 3 4
6 8 -0.16 190 14.43 302 828 3.70 / 16.09 3 5
Average= 3.22 (KJ/cycle)

Cycle 3 GMT 16/11/2016 0: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 23 14.79 442 150 0.15 / 8.77 3 3
2 7 1513.24 46 13.36 2420 1487 1.64 / 10.25 3 3
3 13 1261.88 26 13.62 2100 744 2.38 / 11.00 3 3
4 13 548.04 26 14.09 1120 410 2.79 / 11.41 3 3
5 13 64.52 26 14.64 414 158 2.95 / 11.56 3 3
6 8 -0.16 190 14.42 303 830 3.78 / 12.40 3 7
Average= 3.10 (KJ/cycle)

Cycle 2 GMT 15/11/2016 0:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 24 14.73 473 167 0.17 / 4.61 3 3
2 3 947.60 -1 15.54 0 0 0.00 / 4.61 3 3
3 7 1508.96 74 13.04 2437 2352 2.52 / 6.96 3 3
4 13 383.92 25 14.20 894 317 2.84 / 7.28 3 4
5 13 63.48 25 14.60 417 152 2.99 / 7.43 3 3
6 13 33.44 25 14.57 367 134 3.12 / 7.57 3 3
7 8 -0.24 240 14.34 305 1050 4.17 / 8.62 3 52
Average= 2.87 (KJ/cycle)

Cycle 1 GMT 14/11/2016 0:59: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 24 14.93 369 132 0.13 / 1.42 3 3
2 3 940.36 -1 15.46 0 0 0.00 / 1.42 3 3
3 7 997.36 75 13.20 1743 1726 1.86 / 3.14 3 3
4 13 61.44 25 14.51 461 167 2.03 / 3.31 3 3
5 8 -0.32 240 14.30 331 1136 3.16 / 4.44 3 18
Average= 2.22 (KJ/cycle)

Cycle 0 GMT 13/11/2016 13:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 97.44 24 14.64 357 125 0.13 / 0.13 3 3
2 7 106.16 75 14.56 358 391 0.52 / 0.52 3 3
3 8 0.12 240 14.79 216 767 1.28 / 1.28 3 6
Average= 1.28 (KJ/cycle)