SIO Argo Site:
Pump Diagnostics Page   



Serial= 8482 WMO= 5902490

Return

←PreviousNext→

Cycle 336 GMT 20/12/2024 22:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 11.71 0 0 0.00 / 1702.67 0 0
2 3 0.00 -19 11.72 0 0 0.00 / 1702.67 0 0
3 12 0.04 154 11.05 144 245 0.25 / 1702.91 0 0
4 7 0.00 24 11.06 140 37 0.28 / 1702.95 0 0
5 8 0.08 170 11.04 136 255 0.54 / 1703.20 0 0
Average= 5.05
(KJ/cycle)

Cycle 335 GMT 11/12/2024 7: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.04 -19 11.72 0 0 0.00 / 1702.13 0 0
2 3 0.00 -19 11.74 0 0 0.00 / 1702.13 0 0
3 12 0.00 154 11.09 140 239 0.24 / 1702.37 0 0
4 7 -0.04 24 11.10 141 38 0.28 / 1702.41 0 0
5 8 0.00 170 11.06 139 261 0.54 / 1702.67 0 0
Average= 5.07
(KJ/cycle)

Cycle 334 GMT 10/12/2024 7:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 11.72 0 0 0.00 / 1701.58 0 0
2 3 0.00 -19 11.73 0 0 0.00 / 1701.58 0 0
3 12 0.00 154 11.06 144 245 0.25 / 1701.83 0 0
4 7 0.08 24 11.07 144 38 0.28 / 1701.87 0 0
5 8 0.08 170 11.04 140 263 0.55 / 1702.13 0 0
Average= 5.08
(KJ/cycle)

Cycle 333 GMT 30/11/2024 15:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.08 -19 11.72 0 0 0.00 / 1701.04 0 0
2 3 0.00 -19 11.73 0 0 0.00 / 1701.04 0 0
3 12 0.00 154 11.08 144 246 0.25 / 1701.28 0 0
4 7 0.00 24 11.09 143 38 0.28 / 1701.32 0 0
5 8 -0.04 170 11.07 140 263 0.55 / 1701.58 0 0
Average= 5.09
(KJ/cycle)

Cycle 332 GMT 20/11/2024 23:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 11.71 0 0 0.00 / 1700.49 0 0
2 3 0.00 -19 11.72 0 0 0.00 / 1700.49 0 0
3 12 0.00 154 11.08 143 244 0.24 / 1700.73 0 0
4 7 -0.08 24 11.10 145 39 0.28 / 1700.77 0 0
5 8 0.00 170 11.06 141 265 0.55 / 1701.04 0 0
Average= 5.11
(KJ/cycle)

Cycle 331 GMT 11/11/2024 7:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.04 -19 11.72 0 0 0.00 / 1699.93 1 0
2 3 -0.04 -19 11.73 0 0 0.00 / 1699.93 1 0
3 12 0.00 154 11.10 145 248 0.25 / 1700.18 1 0
4 7 -0.04 24 11.11 145 39 0.29 / 1700.22 0 0
5 8 -0.08 170 11.08 143 269 0.56 / 1700.49 0 0
Average= 5.12
(KJ/cycle)

Cycle 330 GMT 10/11/2024 7:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 -0.04 -19 11.70 0 0 0.00 / 1699.37 1 0
2 3 -0.04 -19 11.72 0 0 0.00 / 1699.37 1 0
3 12 -0.04 154 11.08 146 249 0.25 / 1699.62 0 0
4 7 -0.04 25 11.10 145 40 0.29 / 1699.66 0 0
5 8 -0.04 170 11.06 143 269 0.56 / 1699.93 0 0
Average= 5.14
(KJ/cycle)

Cycle 329 GMT 31/10/2024 15:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 -0.04 -19 11.71 0 0 0.00 / 1698.82 1 0
2 3 0.00 -19 11.72 0 0 0.00 / 1698.82 1 0
3 12 -0.04 154 11.07 147 251 0.25 / 1699.07 1 0
4 7 0.04 24 11.09 145 39 0.29 / 1699.11 0 0
5 8 -0.04 170 11.06 143 269 0.56 / 1699.37 1 0
Average= 5.15
(KJ/cycle)

Cycle 328 GMT 21/10/2024 23:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 11.70 0 0 0.00 / 1698.25 3 1
2 3 0.04 -19 11.71 0 0 0.00 / 1698.25 3 1
3 12 0.00 154 11.09 147 251 0.25 / 1698.50 2 0
4 7 0.00 24 11.12 146 39 0.29 / 1698.54 0 0
5 8 0.12 170 11.07 145 273 0.56 / 1698.82 1 0
Average= 5.16
(KJ/cycle)

Cycle 327 GMT 12/10/2024 7:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 11.70 0 0 0.00 / 1697.67 3 1
2 3 0.08 -19 11.71 0 0 0.00 / 1697.67 3 1
3 12 0.00 154 11.11 152 260 0.26 / 1697.93 3 1
4 7 -0.04 24 11.12 152 41 0.30 / 1697.97 1 1
5 8 0.04 170 11.09 148 279 0.58 / 1698.25 2 1
Average= 5.18
(KJ/cycle)

Cycle 326 GMT 11/10/2024 7:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.04 -19 11.70 0 0 0.00 / 1697.10 4 1
2 3 0.00 -19 11.71 0 0 0.00 / 1697.10 4 1
3 12 0.00 154 11.06 153 261 0.26 / 1697.36 4 1
4 7 -0.04 24 11.09 149 40 0.30 / 1697.40 1 1
5 8 -0.04 170 11.06 146 275 0.57 / 1697.67 3 1
Average= 5.19
(KJ/cycle)

Cycle 325 GMT 1/10/2024 15:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 11.69 0 0 0.00 / 1696.51 7 3
2 3 -0.04 -19 11.70 0 0 0.00 / 1696.51 7 3
3 12 0.04 154 11.05 153 260 0.26 / 1696.77 5 2
4 7 0.00 24 11.09 158 42 0.30 / 1696.81 2 2
5 8 0.04 170 11.04 155 291 0.59 / 1697.10 4 1
Average= 5.21
(KJ/cycle)

Cycle 324 GMT 22/ 9/2024 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.08 -19 11.69 0 0 0.00 / 1695.90 9 4
2 3 0.00 -19 11.70 0 0 0.00 / 1695.90 9 4
3 12 -0.08 154 11.05 157 267 0.27 / 1696.17 8 3
4 7 0.00 24 11.08 159 42 0.31 / 1696.21 3 3
5 8 -0.04 170 11.05 157 295 0.60 / 1696.51 6 3
Average= 5.22
(KJ/cycle)

Cycle 323 GMT 12/ 9/2024 8:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 11.69 0 0 0.00 / 1695.29 11 6
2 3 0.00 -19 11.70 0 0 0.00 / 1695.29 11 6
3 12 -0.04 154 11.09 159 272 0.27 / 1695.56 10 4
4 7 0.00 24 11.10 160 43 0.31 / 1695.60 4 5
5 8 -0.04 170 11.07 159 299 0.61 / 1695.90 8 4
Average= 5.23
(KJ/cycle)

Cycle 322 GMT 11/ 9/2024 8: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.04 -19 11.69 0 0 0.00 / 1694.67 15 9
2 3 -0.04 -19 11.70 0 0 0.00 / 1694.67 15 9
3 12 0.00 154 11.01 161 273 0.27 / 1694.95 13 6
4 7 0.04 24 11.05 159 42 0.32 / 1694.99 6 6
5 8 0.04 170 11.03 159 298 0.61 / 1695.29 10 5
Average= 5.25
(KJ/cycle)

Cycle 321 GMT 1/ 9/2024 16:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.04 -19 11.69 0 0 0.00 / 1694.05 23 15
2 3 0.04 -19 11.69 0 0 0.00 / 1694.05 23 15
3 12 0.00 154 11.02 164 278 0.28 / 1694.33 17 9
4 7 0.00 24 11.02 162 43 0.32 / 1694.37 9 9
5 8 -0.04 170 11.03 162 304 0.62 / 1694.67 14 9
Average= 5.26
(KJ/cycle)

Cycle 320 GMT 23/ 8/2024 0:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.08 -19 11.67 0 0 0.00 / 1693.42 38 31
2 3 -0.04 -19 11.67 0 0 0.00 / 1693.42 38 31
3 12 0.04 154 11.12 164 281 0.28 / 1693.71 25 16
4 7 0.00 24 11.13 161 43 0.32 / 1693.75 16 16
5 8 -0.04 170 11.12 159 301 0.62 / 1694.05 22 15
Average= 5.28
(KJ/cycle)

Cycle 319 GMT 13/ 8/2024 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.48 -19 11.64 0 0 0.00 / 1692.65 62 61
2 3 0.48 -19 11.65 0 0 0.00 / 1692.65 62 61
3 12 0.40 154 11.24 234 405 0.41 / 1693.05 43 32
4 7 0.44 24 11.24 224 60 0.47 / 1693.11 32 31
5 8 0.40 170 11.30 162 311 0.78 / 1693.42 37 31
Average= 5.29
(KJ/cycle)

Cycle 318 GMT 12/ 8/2024 8:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 33 11.03 428 156 0.16 / 1689.18 2 2
2 12 972.60 154 9.51 1747 2559 2.71 / 1691.74 67 60
3 7 960.60 24 9.57 1707 392 3.11 / 1692.13 60 60
4 8 -0.28 170 11.10 274 517 3.62 / 1692.65 65 62
Average= 5.31
(KJ/cycle)

Cycle 317 GMT 2/ 8/2024 15:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 34 11.05 421 158 0.16 / 1685.11 2 2
2 3 965.64 -1 11.65 0 0 0.00 / 1685.11 2 2
3 3 1022.48 1 9.70 1836 18 0.18 / 1685.13 2 2
4 12 1129.44 154 9.26 1963 2799 2.98 / 1687.93 2 2
5 7 1118.76 24 9.37 1938 436 3.41 / 1688.37 2 2
6 13 42.44 44 11.07 327 159 3.57 / 1688.53 2 2
7 8 0.04 170 11.13 264 500 4.07 / 1689.02 2 2
Average= 5.31
(KJ/cycle)

Cycle 316 GMT 23/ 7/2024 22: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 35 11.06 422 163 0.16 / 1681.00 2 2
2 3 960.76 -1 11.65 0 0 0.00 / 1681.00 2 2
3 3 1021.88 1 9.74 1840 18 0.18 / 1681.01 2 2
4 12 1135.84 154 9.30 1971 2823 3.00 / 1683.84 2 2
5 7 1125.76 24 9.42 1944 439 3.44 / 1684.28 2 2
6 13 42.00 44 11.07 329 160 3.60 / 1684.44 2 2
7 8 0.04 170 11.13 274 518 4.12 / 1684.95 2 2
Average= 5.32
(KJ/cycle)

Cycle 315 GMT 14/ 7/2024 4:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 34 11.06 421 158 0.16 / 1674.74 2 2
2 3 955.84 -1 11.65 0 0 0.00 / 1674.74 2 2
3 12 1108.28 3 9.55 1943 56 0.21 / 1674.79 2 2
4 12 1984.24 154 8.42 3180 4123 4.34 / 1678.92 2 2
5 7 1973.72 24 8.54 3163 648 4.99 / 1679.57 2 2
6 13 635.40 44 10.12 1277 569 5.55 / 1680.14 2 2
7 13 57.24 44 11.05 366 178 5.73 / 1680.31 2 2
8 8 0.08 170 11.15 274 519 6.25 / 1680.83 2 2
Average= 5.32
(KJ/cycle)

Cycle 314 GMT 13/ 7/2024 1:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 33 11.08 421 154 0.15 / 1670.66 2 2
2 12 1110.80 154 9.41 1940 2811 2.97 / 1673.47 2 2
3 7 1099.92 24 9.53 1913 438 3.40 / 1673.91 2 2
4 13 37.92 44 11.10 319 156 3.56 / 1674.07 2 2
5 8 -0.08 170 11.14 271 513 4.07 / 1674.58 2 2
Average= 5.32
(KJ/cycle)

Cycle 313 GMT 3/ 7/2024 8:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 33 11.07 435 159 0.16 / 1666.50 2 2
2 3 1032.32 1 9.90 1844 18 0.18 / 1666.52 2 2
3 3 1022.96 1 9.80 1827 18 0.20 / 1666.53 2 2
4 12 1138.48 154 9.41 1972 2858 3.05 / 1669.39 2 2
5 7 1128.52 24 9.53 1958 448 3.50 / 1669.84 2 2
6 13 40.88 44 11.10 322 157 3.66 / 1670.00 2 2
7 8 -0.08 170 11.15 270 512 4.17 / 1670.51 2 2
Average= 5.32
(KJ/cycle)

Cycle 312 GMT 23/ 6/2024 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 33 11.08 429 157 0.16 / 1662.36 2 2
2 12 1125.52 154 9.45 1960 2852 3.01 / 1665.22 2 2
3 7 1115.04 24 9.59 1950 449 3.46 / 1665.66 2 2
4 13 42.20 44 11.10 327 160 3.62 / 1665.82 2 2
5 8 0.04 170 11.15 272 516 4.13 / 1666.34 2 2
Average= 5.32
(KJ/cycle)

Cycle 311 GMT 13/ 6/2024 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 33 11.09 431 158 0.16 / 1656.14 2 2
2 3 1027.72 1 9.95 1840 18 0.18 / 1656.16 2 2
3 12 1115.28 3 9.68 1960 57 0.23 / 1656.22 2 2
4 12 1985.84 154 8.65 3186 4244 4.48 / 1660.46 2 2
5 7 1975.32 24 8.71 3166 662 5.14 / 1661.12 2 2
6 13 354.80 44 10.62 851 398 5.54 / 1661.52 2 2
7 13 42.36 44 11.11 339 166 5.70 / 1661.69 2 2
8 8 -0.20 170 11.17 274 520 6.22 / 1662.21 2 3
Average= 5.33
(KJ/cycle)

Cycle 310 GMT 12/ 6/2024 18: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 33 11.08 438 160 0.16 / 1652.00 2 2
2 12 1122.36 154 9.53 1955 2869 3.03 / 1654.87 2 2
3 7 1111.84 24 9.63 1930 446 3.48 / 1655.31 2 2
4 13 40.68 44 11.10 320 156 3.63 / 1655.47 2 2
5 8 0.04 170 11.17 270 513 4.14 / 1655.98 2 4
Average= 5.32
(KJ/cycle)

Cycle 309 GMT 3/ 6/2024 0:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 34 11.11 416 157 0.16 / 1647.86 2 2
2 12 1103.76 154 9.56 1930 2841 3.00 / 1650.70 2 2
3 7 1093.36 24 9.67 1921 446 3.44 / 1651.15 2 2
4 13 59.84 44 11.08 366 178 3.62 / 1651.32 2 2
5 8 -0.12 170 11.17 271 515 4.14 / 1651.84 2 3
Average= 5.33
(KJ/cycle)

Cycle 308 GMT 24/ 5/2024 7:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 33 11.11 434 159 0.16 / 1643.68 2 2
2 12 1116.16 154 9.58 1951 2878 3.04 / 1646.56 2 2
3 7 1105.60 24 9.70 1925 448 3.49 / 1647.01 2 2
4 13 71.60 44 11.08 377 184 3.67 / 1647.19 2 2
5 8 0.08 170 11.18 269 511 4.18 / 1647.70 2 2
Average= 5.33
(KJ/cycle)

Cycle 307 GMT 14/ 5/2024 13:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 33 11.12 420 154 0.15 / 1637.24 2 2
2 12 1108.16 3 9.77 1960 57 0.21 / 1637.29 2 2
3 12 1987.08 154 8.82 3184 4325 4.54 / 1641.62 2 2
4 7 1977.04 24 8.93 3161 677 5.21 / 1642.30 2 2
5 13 568.20 44 10.38 1179 538 5.75 / 1642.83 2 2
6 13 46.88 44 11.12 345 169 5.92 / 1643.00 2 2
7 8 -0.04 170 11.19 272 517 6.44 / 1643.52 2 3
Average= 5.34
(KJ/cycle)

Cycle 306 GMT 13/ 5/2024 10:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 33 11.11 422 155 0.15 / 1633.10 2 2
2 12 1108.92 154 9.63 1937 2873 3.03 / 1635.97 2 2
3 7 1098.88 24 9.73 1919 448 3.48 / 1636.42 2 2
4 13 33.40 44 11.14 317 155 3.63 / 1636.58 2 2
5 8 -0.12 170 11.18 267 507 4.14 / 1637.08 2 2
Average= 5.33
(KJ/cycle)

Cycle 305 GMT 3/ 5/2024 17:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 33 11.11 421 154 0.15 / 1628.94 2 2
2 12 1103.56 154 9.66 1931 2873 3.03 / 1631.81 2 2
3 7 1092.72 24 9.80 1910 449 3.48 / 1632.26 2 2
4 13 53.48 44 11.11 352 172 3.65 / 1632.43 2 2
5 8 -0.08 170 11.18 269 511 4.16 / 1632.94 2 2
Average= 5.34
(KJ/cycle)

Cycle 304 GMT 24/ 4/2024 0: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 33 11.14 425 156 0.16 / 1624.74 2 2
2 12 1117.72 154 9.66 1954 2907 3.06 / 1627.64 2 2
3 7 1106.56 24 9.80 1927 453 3.52 / 1628.10 2 2
4 13 65.56 44 11.11 361 176 3.69 / 1628.27 2 2
5 8 -0.20 170 11.19 269 512 4.20 / 1628.78 2 2
Average= 5.34
(KJ/cycle)

Cycle 303 GMT 14/ 4/2024 6:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 33 11.14 415 153 0.15 / 1618.43 2 2
2 12 1114.40 3 9.80 1963 58 0.21 / 1618.49 2 2
3 12 1988.56 154 8.93 3188 4384 4.59 / 1622.87 2 2
4 7 1978.52 24 9.00 3174 686 5.28 / 1623.56 2 2
5 13 287.28 44 10.80 743 353 5.63 / 1623.91 2 2
6 13 31.40 44 11.17 319 157 5.79 / 1624.07 2 2
7 8 0.08 170 11.20 269 512 6.30 / 1624.58 2 2
Average= 5.34
(KJ/cycle)

Cycle 302 GMT 13/ 4/2024 3:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 34 11.12 421 159 0.16 / 1614.28 2 2
2 12 1102.04 154 9.70 1936 2892 3.05 / 1617.17 2 2
3 7 1092.12 24 9.84 1915 452 3.50 / 1617.62 2 2
4 13 36.12 44 11.15 315 155 3.66 / 1617.77 2 2
5 8 0.04 170 11.19 265 504 4.16 / 1618.28 2 3
Average= 5.34
(KJ/cycle)

Cycle 301 GMT 3/ 4/2024 10: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 33 11.13 430 158 0.16 / 1610.03 2 2
2 12 1125.72 154 9.71 1969 2944 3.10 / 1612.97 2 2
3 7 1114.76 24 9.85 1946 460 3.56 / 1613.43 2 2
4 13 59.48 44 11.12 359 176 3.74 / 1613.61 2 2
5 8 -0.04 170 11.19 268 510 4.25 / 1614.12 2 2
Average= 5.34
(KJ/cycle)

Cycle 300 GMT 24/ 3/2024 16:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 33 11.12 427 157 0.16 / 1605.83 2 2
2 12 1111.36 154 9.73 1945 2914 3.07 / 1608.74 2 2
3 7 1100.92 24 9.88 1915 454 3.53 / 1609.20 2 2
4 13 36.68 44 11.16 317 156 3.68 / 1609.35 2 2
5 8 -0.04 170 11.19 270 514 4.19 / 1609.87 2 3
Average= 5.35
(KJ/cycle)

Cycle 299 GMT 14/ 3/2024 23: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 32 11.10 416 148 0.15 / 1599.37 2 2
2 3 1036.68 1 10.07 1865 19 0.17 / 1599.38 2 2
3 3 1028.08 1 10.07 1847 19 0.19 / 1599.40 2 2
4 12 1127.48 3 9.72 1979 58 0.24 / 1599.46 2 2
5 12 1988.84 154 8.92 3193 4386 4.63 / 1603.85 2 2
6 7 1978.56 24 9.09 3161 690 5.32 / 1604.54 2 2
7 13 422.04 44 10.62 957 447 5.77 / 1604.98 2 2
8 13 47.24 44 11.13 349 171 5.94 / 1605.15 2 2
9 8 -0.08 170 11.19 273 519 6.46 / 1605.67 2 3
Average= 5.35
(KJ/cycle)

Cycle 298 GMT 13/ 3/2024 20:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 31 11.11 425 146 0.15 / 1595.04 2 2
2 3 1072.52 2 10.04 1895 38 0.18 / 1595.08 2 2
3 3 1037.24 1 10.10 1850 19 0.20 / 1595.10 2 2
4 12 1146.96 154 9.67 1994 2969 3.17 / 1598.07 2 2
5 7 1135.88 24 9.87 1977 468 3.64 / 1598.54 2 2
6 13 72.04 44 11.08 372 181 3.82 / 1598.72 2 2
7 8 -0.08 170 11.18 263 500 4.32 / 1599.22 2 4
Average= 5.35
(KJ/cycle)

Cycle 297 GMT 4/ 3/2024 2:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 32 11.27 430 155 0.16 / 1590.80 2 2
2 12 1119.44 154 9.81 1957 2957 3.11 / 1593.76 2 2
3 7 1108.84 24 9.91 1935 460 3.57 / 1594.22 2 2
4 13 57.68 44 11.11 346 169 3.74 / 1594.39 2 2
5 8 -0.12 170 11.17 266 505 4.25 / 1594.90 2 3
Average= 5.35
(KJ/cycle)

Cycle 296 GMT 23/ 2/2024 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 29 11.50 423 141 0.14 / 1586.44 2 2
2 3 1085.40 2 10.37 1930 40 0.18 / 1586.48 2 2
3 3 1049.44 1 10.40 1890 20 0.20 / 1586.50 2 2
4 12 1136.44 154 9.72 1986 2973 3.17 / 1589.48 2 2
5 7 1125.64 24 10.06 1966 475 3.65 / 1589.95 2 2
6 13 75.88 44 11.28 382 190 3.84 / 1590.14 2 2
7 8 -0.08 170 11.32 265 510 4.35 / 1590.65 2 3
Average= 5.36
(KJ/cycle)

Cycle 295 GMT 13/ 2/2024 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 29 11.73 428 146 0.15 / 1580.20 2 2
2 10 1032.44 3 10.51 1846 58 0.20 / 1580.26 2 2
3 12 1119.92 3 10.12 1988 60 0.26 / 1580.32 2 2
4 12 1986.40 154 8.58 3185 4208 4.47 / 1584.53 2 2
5 7 1976.24 24 8.93 3160 677 5.15 / 1585.20 2 2
6 13 330.92 44 10.97 814 393 5.54 / 1585.60 2 2
7 13 42.20 44 11.46 339 171 5.71 / 1585.77 2 2
8 8 -0.16 170 11.45 274 533 6.25 / 1586.30 2 2
Average= 5.36
(KJ/cycle)

Cycle 294 GMT 12/ 2/2024 12:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 26 11.94 421 131 0.13 / 1575.85 2 2
2 10 1021.64 4 10.78 1850 80 0.21 / 1575.93 2 2
3 3 1048.72 1 10.67 1899 20 0.23 / 1575.95 2 2
4 3 1031.64 1 10.55 1861 20 0.25 / 1575.97 2 2
5 12 1131.64 154 9.49 1969 2878 3.13 / 1578.85 2 2
6 7 1121.80 24 10.04 1956 471 3.60 / 1579.32 2 2
7 13 74.04 44 11.63 379 194 3.79 / 1579.51 2 2
8 8 0.08 170 11.72 272 542 4.34 / 1580.05 2 2
Average= 5.36
(KJ/cycle)

Cycle 293 GMT 2/ 2/2024 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 30 12.27 428 158 0.16 / 1571.57 2 2
2 3 964.32 -1 13.27 0 0 0.00 / 1571.57 2 2
3 12 1122.72 154 9.65 1961 2914 3.07 / 1574.48 2 2
4 7 1111.88 24 10.22 1961 481 3.55 / 1574.96 2 2
5 13 55.28 44 11.94 370 194 3.75 / 1575.16 2 2
6 8 -0.04 170 11.96 277 563 4.31 / 1575.72 2 3
Average= 5.36
(KJ/cycle)

Cycle 292 GMT 24/ 1/2024 1:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 26 12.83 451 150 0.15 / 1567.02 2 2
2 10 1015.28 4 11.77 1856 87 0.24 / 1567.11 2 2
3 3 1029.72 1 11.44 1892 22 0.26 / 1567.13 2 2
4 3 1019.32 1 11.30 1885 21 0.28 / 1567.15 2 2
5 12 1108.24 154 10.07 1946 3018 3.30 / 1570.17 2 2
6 7 1097.56 24 10.56 1926 488 3.79 / 1570.65 2 2
7 13 22.92 44 12.25 313 169 3.96 / 1570.82 2 2
8 8 0.00 170 12.19 283 586 4.54 / 1571.41 2 3
Average= 5.36
(KJ/cycle)

Cycle 291 GMT 14/ 1/2024 8:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 25 13.15 449 148 0.15 / 1560.50 2 2
2 10 1036.36 3 12.23 1893 69 0.22 / 1560.57 2 2
3 3 1046.04 1 11.89 1914 23 0.24 / 1560.59 2 2
4 3 1022.24 1 11.47 1874 21 0.26 / 1560.61 2 2
5 12 1125.52 3 11.70 2007 70 0.33 / 1560.69 2 2
6 12 1986.04 154 9.24 3194 4545 4.88 / 1565.23 2 2
7 7 1975.56 24 9.81 3189 751 5.63 / 1565.98 2 2
8 13 119.04 44 12.58 480 266 5.89 / 1566.25 2 2
9 8 0.00 170 12.72 287 621 6.51 / 1566.87 2 4
Average= 5.37
(KJ/cycle)

Cycle 290 GMT 13/ 1/2024 5:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 25 13.50 440 148 0.15 / 1556.24 2 2
2 3 1031.80 1 11.87 1896 23 0.17 / 1556.26 2 2
3 3 1024.68 1 11.57 1888 22 0.19 / 1556.28 2 2
4 12 1134.76 154 9.09 1962 2747 2.94 / 1559.03 2 2
5 7 1125.04 24 10.75 1977 510 3.45 / 1559.54 2 2
6 13 43.08 44 13.04 348 200 3.65 / 1559.74 2 2
7 8 -0.08 170 12.96 280 617 4.27 / 1560.35 2 4
Average= 5.36
(KJ/cycle)

Cycle 289 GMT 3/ 1/2024 11:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 25 13.83 438 151 0.15 / 1551.72 2 2
2 12 1109.92 154 9.91 1952 2979 3.13 / 1554.70 2 2
3 7 1100.00 24 11.22 1948 525 3.66 / 1555.23 2 2
4 13 20.48 44 13.46 324 192 3.85 / 1555.42 2 2
5 8 -0.16 170 13.28 296 668 4.52 / 1556.09 2 6
Average= 5.37
(KJ/cycle)

Cycle 288 GMT 24/12/2023 18:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 26 14.08 445 163 0.16 / 1547.20 2 2
2 3 968.40 -1 14.85 0 0 0.00 / 1547.20 2 2
3 12 1141.88 154 10.18 2005 3143 3.31 / 1550.35 2 2
4 7 1131.48 24 11.30 2012 546 3.85 / 1550.89 2 2
5 8 0.08 170 13.53 295 679 4.53 / 1551.57 2 5
Average= 5.37
(KJ/cycle)

Cycle 287 GMT 15/12/2023 1: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 25 14.25 446 159 0.16 / 1540.23 2 2
2 12 1102.64 3 11.60 1994 69 0.23 / 1540.30 2 2
3 12 1986.84 154 10.01 3213 4953 5.18 / 1545.25 2 2
4 7 1975.96 24 10.62 3192 814 5.99 / 1546.06 2 2
5 13 108.60 44 13.70 475 286 6.28 / 1546.35 2 2
6 8 0.08 170 13.80 295 692 6.97 / 1547.04 2 5
Average= 5.37
(KJ/cycle)

Cycle 286 GMT 13/12/2023 22:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 25 14.25 443 158 0.16 / 1535.61 2 2
2 12 1104.44 154 10.07 1948 3021 3.18 / 1538.63 2 2
3 7 1093.48 24 11.41 1941 532 3.71 / 1539.16 2 2
4 13 19.80 44 14.17 321 200 3.91 / 1539.36 2 2
5 8 -0.08 170 13.95 299 709 4.62 / 1540.07 2 6
Average= 5.37
(KJ/cycle)

Cycle 285 GMT 4/12/2023 5:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 24 14.24 465 159 0.16 / 1531.01 2 2
2 3 1046.64 1 12.30 1923 24 0.18 / 1531.03 2 2
3 3 1020.08 1 11.69 1893 22 0.20 / 1531.06 2 2
4 12 1127.28 154 10.31 1982 3147 3.35 / 1534.20 2 2
5 7 1116.24 24 11.46 1972 542 3.89 / 1534.74 2 2
6 8 0.04 170 14.01 296 705 4.60 / 1535.45 2 4
Average= 5.37
(KJ/cycle)

Cycle 284 GMT 24/11/2023 11:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 25 14.29 441 158 0.16 / 1526.40 2 2
2 12 1093.16 154 10.65 1939 3180 3.34 / 1529.58 2 2
3 7 1082.00 24 11.60 1933 538 3.88 / 1530.12 2 2
4 8 -0.08 170 14.00 306 728 4.60 / 1530.85 2 4
Average= 5.37
(KJ/cycle)

Cycle 283 GMT 14/11/2023 18:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 25 14.24 448 159 0.16 / 1519.28 2 2
2 12 1102.44 3 11.83 2000 71 0.23 / 1519.35 2 2
3 12 1987.48 154 10.30 3219 5106 5.34 / 1524.45 2 2
4 7 1975.76 24 10.81 3208 832 6.17 / 1525.29 2 2
5 13 54.44 44 14.11 385 239 6.41 / 1525.53 2 2
6 8 0.16 170 14.14 300 721 7.13 / 1526.25 2 5
Average= 5.37
(KJ/cycle)

Cycle 282 GMT 13/11/2023 15:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 25 14.30 446 159 0.16 / 1514.78 2 2
2 12 1125.76 154 10.15 1975 3087 3.25 / 1517.87 2 2
3 7 1115.28 24 11.43 1974 542 3.79 / 1518.41 2 2
4 8 0.00 170 14.14 293 704 4.49 / 1519.12 2 3
Average= 5.37
(KJ/cycle)

Cycle 281 GMT 3/11/2023 22:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 25 14.32 457 164 0.16 / 1510.21 2 2
2 12 1110.28 154 10.48 1962 3167 3.33 / 1513.37 2 2
3 7 1099.24 24 11.54 1955 541 3.87 / 1513.91 2 2
4 8 0.12 170 14.18 295 711 4.58 / 1514.63 2 3
Average= 5.37
(KJ/cycle)

Cycle 280 GMT 25/10/2023 4:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 25 14.37 460 165 0.17 / 1505.46 2 2
2 12 1115.08 154 10.82 1977 3294 3.46 / 1508.75 2 2
3 7 1104.00 24 11.75 1966 554 4.01 / 1509.31 2 2
4 8 -0.08 170 14.26 304 737 4.75 / 1510.04 2 5
Average= 5.37
(KJ/cycle)

Cycle 279 GMT 15/10/2023 11:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 25 14.36 468 168 0.17 / 1498.16 2 2
2 12 1110.72 3 12.04 2009 73 0.24 / 1498.23 2 2
3 12 1994.04 154 10.46 3230 5203 5.44 / 1503.43 2 2
4 7 1983.20 24 11.02 3205 848 6.29 / 1504.28 2 2
5 13 88.56 44 14.13 446 277 6.57 / 1504.56 2 3
6 8 -0.08 170 14.32 301 733 7.30 / 1505.29 2 4
Average= 5.38
(KJ/cycle)

Cycle 278 GMT 14/10/2023 8:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 25 14.42 455 164 0.16 / 1493.70 2 2
2 12 1096.12 154 10.13 1934 3017 3.18 / 1496.71 2 2
3 7 1084.68 24 11.60 1942 541 3.72 / 1497.25 2 2
4 8 0.00 170 14.33 302 736 4.46 / 1497.99 2 3
Average= 5.37
(KJ/cycle)

Cycle 277 GMT 4/10/2023 15:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 26 14.42 453 170 0.17 / 1489.07 2 2
2 3 959.08 -1 14.85 0 0 0.00 / 1489.07 2 2
3 12 1123.64 154 10.37 1980 3162 3.33 / 1492.24 2 2
4 7 1111.88 24 11.65 1975 552 3.88 / 1492.79 2 2
5 8 -0.12 170 14.35 305 744 4.63 / 1493.53 2 8
Average= 5.37
(KJ/cycle)

Cycle 276 GMT 24/ 9/2023 22: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 25 14.42 478 172 0.17 / 1484.35 2 2
2 3 1024.96 1 12.38 1915 24 0.20 / 1484.37 2 2
3 12 1112.40 154 10.67 1971 3239 3.43 / 1487.61 2 2
4 7 1100.96 24 11.80 1963 556 3.99 / 1488.16 2 2
5 8 -0.08 170 14.38 303 741 4.73 / 1488.90 2 8
Average= 5.38
(KJ/cycle)

Cycle 275 GMT 15/ 9/2023 4:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 24 14.41 460 159 0.16 / 1476.98 2 2
2 3 1028.80 1 12.38 1911 24 0.18 / 1477.00 2 2
3 12 1117.76 3 11.85 2006 71 0.25 / 1477.07 2 2
4 12 1992.44 154 10.52 3226 5226 5.48 / 1482.30 2 2
5 7 1981.24 24 11.08 3221 857 6.34 / 1483.16 2 2
6 13 79.00 44 14.24 432 271 6.61 / 1483.43 2 2
7 8 -0.08 170 14.42 304 745 7.35 / 1484.17 2 4
Average= 5.38
(KJ/cycle)

Cycle 274 GMT 14/ 9/2023 1:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 25 14.44 459 166 0.17 / 1472.43 2 2
2 3 1022.72 1 12.18 1923 23 0.19 / 1472.45 2 2
3 12 1116.20 154 10.20 1963 3083 3.27 / 1475.54 2 2
4 7 1105.16 24 11.63 1965 548 3.82 / 1476.08 2 2
5 8 0.04 170 14.40 301 737 4.56 / 1476.82 2 5
Average= 5.37
(KJ/cycle)

Cycle 273 GMT 4/ 9/2023 8:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 26 14.40 463 173 0.17 / 1467.80 2 2
2 3 971.44 -1 14.83 0 0 0.00 / 1467.80 2 2
3 12 1118.72 154 10.44 1973 3172 3.35 / 1470.98 2 2
4 7 1107.52 24 11.68 1962 550 3.90 / 1471.53 2 2
5 8 0.08 170 14.42 300 735 4.63 / 1472.26 2 4
Average= 5.37
(KJ/cycle)

Cycle 272 GMT 25/ 8/2023 15:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 25 14.41 468 169 0.17 / 1463.08 2 2
2 3 1037.08 1 12.78 1924 25 0.19 / 1463.10 2 2
3 12 1113.04 154 10.68 1970 3240 3.43 / 1466.34 2 2
4 7 1101.36 24 11.84 1969 560 3.99 / 1466.90 2 2
5 8 -0.04 170 14.41 297 728 4.72 / 1467.63 2 6
Average= 5.38
(KJ/cycle)

Cycle 271 GMT 15/ 8/2023 21:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 24 14.41 447 155 0.15 / 1455.72 2 2
2 12 1111.88 3 12.08 2015 73 0.23 / 1455.79 2 2
3 12 1983.28 154 10.58 3223 5251 5.48 / 1461.04 2 2
4 7 1971.60 24 11.12 3207 856 6.33 / 1461.90 2 2
5 13 76.80 44 14.26 428 269 6.60 / 1462.17 2 2
6 8 0.08 170 14.44 303 744 7.35 / 1462.91 2 10
Average= 5.38
(KJ/cycle)

Cycle 270 GMT 14/ 8/2023 18:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 25 14.43 451 163 0.16 / 1450.98 2 2
2 12 1109.36 154 10.22 1950 3069 3.23 / 1454.05 2 2
3 7 1098.24 24 11.64 1956 546 3.78 / 1454.60 2 2
4 13 41.44 44 14.34 364 230 4.01 / 1454.83 2 2
5 8 -0.12 170 14.45 300 737 4.74 / 1455.56 2 7
Average= 5.37
(KJ/cycle)

Cycle 269 GMT 5/ 8/2023 1:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 24 14.42 456 158 0.16 / 1446.37 2 2
2 12 1115.56 154 10.44 1969 3166 3.32 / 1449.54 2 2
3 7 1104.36 24 11.69 1960 550 3.87 / 1450.09 2 2
4 8 0.00 170 14.41 298 730 4.60 / 1450.82 2 8
Average= 5.37
(KJ/cycle)

Cycle 268 GMT 26/ 7/2023 8:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 25 14.41 447 161 0.16 / 1441.69 2 2
2 12 1111.60 154 10.67 1964 3227 3.39 / 1444.92 2 2
3 7 1099.88 24 11.84 1964 558 3.95 / 1445.48 2 2
4 8 0.16 170 14.43 301 738 4.68 / 1446.22 2 4
Average= 5.38
(KJ/cycle)

Cycle 267 GMT 16/ 7/2023 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 24 14.40 456 158 0.16 / 1434.35 2 2
2 12 1103.64 3 12.08 1996 72 0.23 / 1434.42 2 2
3 12 1974.36 154 10.63 3208 5252 5.48 / 1439.67 2 2
4 7 1962.20 24 11.15 3185 852 6.33 / 1440.53 2 2
5 13 63.40 44 14.29 406 255 6.59 / 1440.78 2 2
6 8 -0.08 170 14.43 306 751 7.34 / 1441.53 2 9
Average= 5.38
(KJ/cycle)

Cycle 266 GMT 15/ 7/2023 12: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 25 14.41 453 163 0.16 / 1429.62 2 2
2 12 1101.72 154 10.26 1942 3068 3.23 / 1432.69 2 2
3 7 1090.64 24 11.64 1952 545 3.78 / 1433.23 2 2
4 13 19.44 44 14.35 333 210 3.99 / 1433.45 2 2
5 8 0.04 170 14.44 304 746 4.73 / 1434.19 2 5
Average= 5.37
(KJ/cycle)

Cycle 265 GMT 5/ 7/2023 18:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 25 14.38 455 164 0.16 / 1424.97 2 2
2 3 963.48 -1 14.83 0 0 0.00 / 1424.97 2 2
3 12 1130.56 154 10.39 1987 3179 3.34 / 1428.15 2 2
4 7 1119.72 24 11.66 1999 559 3.90 / 1428.71 2 2
5 8 0.00 170 14.41 306 750 4.65 / 1429.46 2 6
Average= 5.37
(KJ/cycle)

Cycle 264 GMT 26/ 6/2023 1:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 25 14.36 469 168 0.17 / 1420.29 2 2
2 12 1115.72 154 10.57 1968 3203 3.37 / 1423.49 2 2
3 7 1104.00 24 11.79 1977 559 3.93 / 1424.05 2 2
4 8 0.12 170 14.40 308 754 4.69 / 1424.81 2 5
Average= 5.38
(KJ/cycle)

Cycle 263 GMT 16/ 6/2023 8: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 25 14.38 454 163 0.16 / 1412.89 2 2
2 3 961.84 -1 14.84 0 0 0.00 / 1412.89 2 2
3 12 1125.60 3 11.83 2025 72 0.24 / 1412.97 2 2
4 12 1983.72 154 10.63 3226 5281 5.52 / 1418.25 2 2
5 7 1971.84 24 11.20 3198 860 6.38 / 1419.11 2 2
6 13 58.32 44 14.29 403 253 6.63 / 1419.36 2 3
7 8 -0.12 170 14.42 310 760 7.39 / 1420.12 2 8
Average= 5.38
(KJ/cycle)

Cycle 262 GMT 15/ 6/2023 5:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 26 14.39 461 172 0.17 / 1408.39 2 2
2 3 936.56 -1 14.83 0 0 0.00 / 1408.39 2 2
3 12 1089.68 154 10.26 1926 3043 3.22 / 1411.43 2 2
4 7 1078.20 24 11.65 1941 543 3.76 / 1411.98 2 2
5 8 0.08 170 14.41 308 755 4.51 / 1412.73 2 4
Average= 5.37
(KJ/cycle)

Cycle 261 GMT 5/ 6/2023 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 26 14.38 467 175 0.17 / 1403.80 2 2
2 12 1100.04 154 10.41 1947 3121 3.30 / 1406.92 2 2
3 7 1088.80 24 11.67 1944 544 3.84 / 1407.46 2 2
4 8 -0.08 170 14.41 308 755 4.59 / 1408.22 2 4
Average= 5.37
(KJ/cycle)

Cycle 260 GMT 26/ 5/2023 19: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 25 14.38 467 168 0.17 / 1398.88 2 2
2 12 1124.32 154 10.54 1976 3207 3.38 / 1402.09 2 2
3 7 1113.36 24 11.79 1990 563 3.94 / 1402.65 2 2
4 13 20.04 44 14.35 340 215 4.15 / 1402.87 2 3
5 8 -0.08 170 14.42 308 755 4.91 / 1403.62 2 6
Average= 5.38
(KJ/cycle)

Cycle 259 GMT 17/ 5/2023 1:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 25 14.36 471 169 0.17 / 1391.51 2 2
2 12 1110.44 3 11.83 2002 71 0.24 / 1391.58 2 2
3 12 1983.00 154 10.60 3222 5260 5.50 / 1396.84 2 2
4 7 1971.28 24 11.19 3199 859 6.36 / 1397.70 2 2
5 13 68.16 44 14.28 417 262 6.62 / 1397.96 2 3
6 8 0.00 170 14.43 307 753 7.37 / 1398.72 2 7
Average= 5.38
(KJ/cycle)

Cycle 258 GMT 15/ 5/2023 23:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 25 14.36 469 168 0.17 / 1386.92 2 2
2 3 1055.64 1 12.85 1945 25 0.19 / 1386.95 2 2
3 12 1123.80 154 10.24 1970 3107 3.30 / 1390.05 2 2
4 7 1113.24 24 11.63 1970 550 3.85 / 1390.60 2 2
5 8 0.08 170 14.41 302 740 4.59 / 1391.34 2 4
Average= 5.37
(KJ/cycle)

Cycle 257 GMT 6/ 5/2023 6: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 25 14.31 454 162 0.16 / 1382.28 2 2
2 3 1022.52 1 12.51 1932 24 0.19 / 1382.30 2 2
3 12 1120.64 154 10.35 1974 3146 3.33 / 1385.45 2 2
4 7 1109.88 24 11.65 1974 552 3.88 / 1386.00 2 2
5 8 -0.12 170 14.40 306 749 4.63 / 1386.75 2 5
Average= 5.38
(KJ/cycle)

Cycle 256 GMT 26/ 4/2023 12:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 25 14.36 451 162 0.16 / 1377.65 2 2
2 12 1108.68 154 10.49 1957 3161 3.32 / 1380.81 2 2
3 7 1097.72 24 11.78 1965 556 3.88 / 1381.37 2 2
4 8 -0.04 170 14.42 306 750 4.63 / 1382.12 2 9
Average= 5.38
(KJ/cycle)

Cycle 255 GMT 16/ 4/2023 19:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 25 14.34 457 164 0.16 / 1370.30 2 2
2 12 1116.76 3 12.04 2012 73 0.24 / 1370.37 2 2
3 12 1983.96 154 10.56 3216 5230 5.47 / 1375.60 2 2
4 7 1972.20 24 11.17 3208 860 6.33 / 1376.46 2 2
5 13 82.04 44 14.26 443 278 6.60 / 1376.74 2 2
6 8 0.00 170 14.41 306 750 7.35 / 1377.49 2 7
Average= 5.38
(KJ/cycle)

Cycle 254 GMT 15/ 4/2023 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 25 14.35 448 161 0.16 / 1365.51 2 2
2 12 1112.48 154 10.23 1961 3089 3.25 / 1368.60 2 2
3 7 1101.24 24 11.62 1984 553 3.80 / 1369.15 2 2
4 13 43.84 44 14.29 377 237 4.04 / 1369.39 2 2
5 8 0.04 170 14.40 305 747 4.79 / 1370.14 2 9
Average= 5.37
(KJ/cycle)

Cycle 253 GMT 5/ 4/2023 23: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 25 14.35 455 163 0.16 / 1360.70 2 2
2 12 1108.64 154 10.37 1958 3127 3.29 / 1363.83 2 2
3 7 1097.68 24 11.64 1972 551 3.84 / 1364.38 2 2
4 13 20.20 44 14.33 337 212 4.05 / 1364.59 2 2
5 8 -0.16 170 14.39 309 756 4.81 / 1365.35 2 6
Average= 5.38
(KJ/cycle)

Cycle 252 GMT 27/ 3/2023 5:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 24 14.38 453 156 0.16 / 1355.81 2 2
2 3 1020.56 1 12.54 1927 24 0.18 / 1355.84 2 2
3 12 1117.04 154 10.45 1970 3170 3.35 / 1359.01 2 2
4 7 1105.44 24 11.76 1972 557 3.91 / 1359.56 2 2
5 13 39.52 44 14.32 361 227 4.13 / 1359.79 2 3
6 8 -0.20 170 14.40 306 749 4.88 / 1360.54 2 6
Average= 5.38
(KJ/cycle)

Cycle 251 GMT 17/ 3/2023 12:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 26 14.36 451 168 0.17 / 1348.47 2 2
2 3 945.88 -1 14.91 0 0 0.00 / 1348.47 2 2
3 12 1109.64 3 11.85 2005 71 0.24 / 1348.54 2 2
4 12 1985.48 154 10.55 3223 5236 5.48 / 1353.78 2 2
5 7 1974.28 24 11.19 3204 860 6.34 / 1354.64 2 2
6 13 74.20 44 14.27 431 271 6.61 / 1354.91 2 2
7 8 -0.08 170 14.41 304 745 7.35 / 1355.65 2 10
Average= 5.38
(KJ/cycle)

Cycle 250 GMT 16/ 3/2023 9:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 25 14.34 448 161 0.16 / 1343.67 2 2
2 3 973.48 -1 14.88 0 0 0.00 / 1343.67 2 2
3 12 1130.92 154 10.23 1981 3121 3.28 / 1346.80 2 2
4 7 1119.12 24 11.61 1989 554 3.84 / 1347.35 2 2
5 13 23.24 44 14.32 339 214 4.05 / 1347.56 2 2
6 8 0.00 170 14.40 302 739 4.79 / 1348.30 2 7
Average= 5.37
(KJ/cycle)

Cycle 249 GMT 6/ 3/2023 15:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 25 14.36 452 162 0.16 / 1338.86 2 2
2 3 957.32 -1 14.91 0 0 0.00 / 1338.86 2 2
3 12 1117.68 154 10.37 1969 3144 3.31 / 1342.00 2 2
4 7 1106.36 24 11.64 1975 552 3.86 / 1342.55 2 2
5 13 18.52 44 14.32 333 210 4.07 / 1342.76 2 2
6 8 -0.04 170 14.37 307 750 4.82 / 1343.51 2 7
Average= 5.37
(KJ/cycle)

Cycle 248 GMT 24/ 2/2023 22:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 25 14.31 463 166 0.17 / 1333.99 2 2
2 12 1123.52 154 10.47 1976 3186 3.35 / 1337.18 2 2
3 7 1112.64 24 11.73 1993 561 3.91 / 1337.74 2 2
4 13 15.92 44 14.34 329 208 4.12 / 1337.95 2 3
5 8 -0.16 170 14.37 307 750 4.87 / 1338.70 2 7
Average= 5.38
(KJ/cycle)

Cycle 247 GMT 15/ 2/2023 5:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 25 14.30 470 168 0.17 / 1326.64 2 2
2 3 1032.20 1 12.70 1925 24 0.19 / 1326.66 2 2
3 3 1018.92 1 12.18 1929 23 0.22 / 1326.69 2 2
4 12 1128.84 3 11.83 2041 72 0.29 / 1326.76 2 2
5 12 1982.28 154 10.57 3214 5232 5.52 / 1331.99 2 2
6 7 1970.32 24 11.24 3189 860 6.38 / 1332.85 2 2
7 13 34.24 44 14.31 361 227 6.61 / 1333.08 2 3
8 8 0.00 170 14.38 306 748 7.36 / 1333.83 2 6
Average= 5.38
(KJ/cycle)

Cycle 246 GMT 14/ 2/2023 3: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 25 14.29 458 164 0.16 / 1322.08 2 2
2 12 1111.88 154 10.29 1951 3092 3.26 / 1325.18 2 2
3 7 1101.52 24 11.63 1961 547 3.80 / 1325.72 2 2
4 8 0.08 170 14.36 306 747 4.55 / 1326.47 2 4
Average= 5.37
(KJ/cycle)

Cycle 245 GMT 4/ 2/2023 9:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 26 14.30 460 171 0.17 / 1317.52 2 2
2 3 965.96 -1 14.93 0 0 0.00 / 1317.52 2 2
3 12 1110.80 154 10.37 1953 3119 3.29 / 1320.63 2 2
4 7 1100.20 24 11.66 1960 548 3.84 / 1321.18 2 2
5 8 -0.12 170 14.37 302 738 4.58 / 1321.92 2 6
Average= 5.37
(KJ/cycle)

Cycle 244 GMT 25/ 1/2023 16:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 25 14.36 467 168 0.17 / 1312.88 2 2
2 12 1121.04 154 10.44 1969 3166 3.33 / 1316.05 2 2
3 7 1110.16 24 11.73 1973 555 3.89 / 1316.60 2 2
4 8 -0.08 170 14.37 304 743 4.63 / 1317.34 2 6
Average= 5.38
(KJ/cycle)

Cycle 243 GMT 15/ 1/2023 23:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 26 14.31 448 167 0.17 / 1305.57 2 2
2 3 942.92 -1 14.95 0 0 0.00 / 1305.57 2 2
3 12 1098.12 3 11.88 1977 70 0.24 / 1305.64 2 2
4 12 1982.48 154 10.50 3213 5195 5.43 / 1310.84 2 2
5 7 1970.80 24 11.19 3199 859 6.29 / 1311.70 2 2
6 13 78.64 44 14.25 432 271 6.56 / 1311.97 2 2
7 8 0.00 170 14.39 304 744 7.31 / 1312.71 2 5
Average= 5.38
(KJ/cycle)

Cycle 242 GMT 14/ 1/2023 20:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 25 14.29 454 162 0.16 / 1300.81 2 2
2 12 1119.04 154 10.28 1965 3111 3.27 / 1303.92 2 2
3 7 1107.88 24 11.62 1969 549 3.82 / 1304.47 2 2
4 13 21.60 44 14.32 327 206 4.03 / 1304.67 2 2
5 8 -0.04 170 14.37 301 735 4.76 / 1305.41 2 6
Average= 5.37
(KJ/cycle)

Cycle 241 GMT 5/ 1/2023 3:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 25 14.28 452 161 0.16 / 1296.23 2 2
2 12 1115.60 154 10.35 1961 3126 3.29 / 1299.36 2 2
3 7 1104.28 24 11.66 1965 550 3.84 / 1299.91 2 2
4 8 0.08 170 14.37 302 738 4.57 / 1300.64 2 6
Average= 5.37
(KJ/cycle)

Cycle 240 GMT 26/12/2022 10: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 25 14.30 455 163 0.16 / 1291.62 2 2
2 12 1110.28 154 10.42 1960 3145 3.31 / 1294.76 2 2
3 7 1099.28 24 11.71 1976 555 3.86 / 1295.32 2 2
4 8 -0.04 170 14.35 307 749 4.61 / 1296.07 2 5
Average= 5.38
(KJ/cycle)

Cycle 239 GMT 16/12/2022 16:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 25 14.26 476 170 0.17 / 1284.34 2 2
2 12 1113.20 3 11.90 2014 72 0.24 / 1284.42 2 2
3 12 1987.24 154 10.45 3224 5188 5.43 / 1289.60 2 2
4 7 1975.84 24 11.16 3219 862 6.29 / 1290.47 2 2
5 13 42.96 44 14.28 374 235 6.53 / 1290.70 2 2
6 8 -0.08 170 14.36 309 754 7.28 / 1291.46 2 4
Average= 5.38
(KJ/cycle)

Cycle 238 GMT 15/12/2022 13:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 25 14.29 462 165 0.17 / 1279.72 2 2
2 12 1133.72 154 10.24 1994 3144 3.31 / 1282.86 2 2
3 7 1122.76 24 11.61 2003 558 3.87 / 1283.42 2 2
4 8 -0.08 170 14.33 309 753 4.62 / 1284.17 2 8
Average= 5.37
(KJ/cycle)

Cycle 237 GMT 5/12/2022 20:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 25 14.27 466 166 0.17 / 1275.10 2 2
2 12 1121.28 154 10.34 1977 3148 3.31 / 1278.25 2 2
3 7 1110.36 24 11.65 1990 556 3.87 / 1278.80 2 2
4 8 0.00 170 14.34 308 751 4.62 / 1279.55 2 5
Average= 5.38
(KJ/cycle)

Cycle 236 GMT 26/11/2022 3: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 25 14.30 450 161 0.16 / 1270.49 2 2
2 12 1112.20 154 10.39 1963 3141 3.30 / 1273.63 2 2
3 7 1100.56 24 11.72 1964 552 3.85 / 1274.18 2 2
4 8 0.04 170 14.34 308 751 4.61 / 1274.93 2 3
Average= 5.38
(KJ/cycle)

Cycle 235 GMT 16/11/2022 9:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 24 14.25 466 159 0.16 / 1263.21 2 2
2 3 1031.88 1 12.65 1930 24 0.18 / 1263.24 2 2
3 12 1126.76 3 11.98 2028 73 0.26 / 1263.31 2 2
4 12 1981.32 154 10.39 3217 5147 5.40 / 1268.46 2 2
5 7 1969.24 24 11.15 3183 852 6.26 / 1269.31 2 2
6 13 76.24 44 14.23 428 268 6.52 / 1269.58 2 2
7 8 -0.12 170 14.36 308 752 7.28 / 1270.33 2 5
Average= 5.38
(KJ/cycle)

Cycle 234 GMT 15/11/2022 7:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 25 14.28 451 161 0.16 / 1258.67 2 2
2 12 1109.56 154 10.28 1959 3101 3.26 / 1261.77 2 2
3 7 1099.24 24 11.66 1963 549 3.81 / 1262.32 2 2
4 8 0.00 170 14.34 301 734 4.55 / 1263.05 2 7
Average= 5.37
(KJ/cycle)

Cycle 233 GMT 5/11/2022 13:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 25 14.27 456 163 0.16 / 1254.07 2 2
2 12 1119.12 154 10.34 1972 3140 3.30 / 1257.21 2 2
3 7 1108.28 24 11.66 1978 554 3.86 / 1257.77 2 2
4 8 0.12 170 14.33 304 741 4.60 / 1258.51 2 5
Average= 5.38
(KJ/cycle)

Cycle 232 GMT 26/10/2022 20:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 26 14.30 454 169 0.17 / 1249.49 2 2
2 3 936.44 -1 15.02 0 0 0.00 / 1249.49 2 2
3 12 1107.00 154 10.42 1953 3134 3.30 / 1252.62 2 2
4 7 1096.76 24 11.73 1957 551 3.85 / 1253.17 2 2
5 8 -0.12 170 14.34 303 739 4.59 / 1253.91 2 6
Average= 5.38
(KJ/cycle)

Cycle 231 GMT 17/10/2022 3:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 25 14.23 457 163 0.16 / 1242.30 2 2
2 3 956.28 -1 15.02 0 0 0.00 / 1242.30 2 2
3 12 1110.16 3 11.88 2007 72 0.23 / 1242.37 2 2
4 12 1968.16 154 10.31 3197 5076 5.31 / 1247.45 2 2
5 7 1956.44 24 11.15 3181 851 6.16 / 1248.30 2 2
6 13 87.40 44 14.21 444 278 6.44 / 1248.58 2 2
7 8 0.08 170 14.36 304 742 7.18 / 1249.32 2 6
Average= 5.38
(KJ/cycle)

Cycle 230 GMT 15/10/2022 23:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 26 14.28 447 166 0.17 / 1237.55 2 2
2 3 946.48 -1 15.02 0 0 0.00 / 1237.55 2 2
3 12 1114.76 154 10.26 1957 3092 3.26 / 1240.64 2 2
4 7 1105.00 24 11.63 1967 549 3.81 / 1241.19 2 2
5 13 17.36 44 14.27 325 204 4.01 / 1241.39 2 2
6 8 -0.08 170 14.31 305 742 4.75 / 1242.14 2 6
Average= 5.38
(KJ/cycle)

Cycle 229 GMT 6/10/2022 6:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 25 14.26 466 166 0.17 / 1232.94 2 2
2 3 1032.56 1 12.79 1926 25 0.19 / 1232.97 2 2
3 12 1123.72 154 10.30 1972 3128 3.32 / 1236.10 2 2
4 7 1113.04 24 11.66 1979 554 3.87 / 1236.65 2 2
5 8 0.00 170 14.32 301 733 4.61 / 1237.38 2 3
Average= 5.38
(KJ/cycle)

Cycle 228 GMT 26/ 9/2022 13: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 25 14.23 455 162 0.16 / 1228.39 2 2
2 12 1096.24 154 10.38 1942 3104 3.27 / 1231.49 2 2
3 7 1085.08 24 11.72 1939 545 3.81 / 1232.04 2 2
4 8 -0.04 170 14.32 304 740 4.55 / 1232.78 2 5
Average= 5.38
(KJ/cycle)

Cycle 227 GMT 16/ 9/2022 19:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 26 14.22 469 173 0.17 / 1221.24 2 2
2 12 1115.68 3 11.85 2022 72 0.25 / 1221.31 2 2
3 12 1972.88 154 10.24 3204 5053 5.30 / 1226.36 2 2
4 7 1960.64 24 11.11 3177 847 6.14 / 1227.21 2 2
5 13 84.28 44 14.21 439 274 6.42 / 1227.48 2 2
6 8 0.00 170 14.36 304 742 7.16 / 1228.23 2 8
Average= 5.39
(KJ/cycle)

Cycle 226 GMT 15/ 9/2022 16:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 25 14.27 463 165 0.17 / 1216.68 2 2
2 3 1033.28 1 12.66 1936 25 0.19 / 1216.71 2 2
3 12 1118.48 154 10.20 1965 3087 3.28 / 1219.79 2 2
4 7 1108.04 24 11.64 1977 552 3.83 / 1220.34 2 2
5 8 0.08 170 14.32 296 721 4.55 / 1221.06 2 4
Average= 5.38
(KJ/cycle)

Cycle 225 GMT 5/ 9/2022 23:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 25 14.22 457 162 0.16 / 1212.13 2 2
2 12 1109.08 154 10.32 1956 3109 3.27 / 1215.24 2 2
3 7 1098.28 24 11.67 1960 549 3.82 / 1215.79 2 2
4 8 0.08 170 14.31 299 727 4.55 / 1216.52 2 9
Average= 5.38
(KJ/cycle)

Cycle 224 GMT 27/ 8/2022 5:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 25 14.26 458 163 0.16 / 1207.31 2 2
2 12 1121.12 154 10.33 1971 3136 3.30 / 1210.45 2 2
3 7 1109.84 24 11.73 1977 557 3.86 / 1211.00 2 2
4 13 41.56 44 14.25 362 227 4.08 / 1211.23 2 2
5 8 -0.16 170 14.33 303 738 4.82 / 1211.97 2 3
Average= 5.39
(KJ/cycle)

Cycle 223 GMT 17/ 8/2022 12:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 25 14.24 464 165 0.17 / 1200.15 2 2
2 12 1135.92 3 11.87 2035 72 0.24 / 1200.23 2 2
3 12 1973.72 154 10.22 3201 5038 5.28 / 1205.26 2 2
4 7 1961.76 24 11.12 3199 854 6.13 / 1206.12 2 2
5 13 101.52 44 14.17 469 292 6.42 / 1206.41 2 2
6 8 0.00 170 14.36 302 737 7.16 / 1207.15 2 10
Average= 5.39
(KJ/cycle)

Cycle 222 GMT 16/ 8/2022 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 25 14.25 454 162 0.16 / 1195.62 2 2
2 12 1109.68 154 10.25 1954 3084 3.25 / 1198.71 2 2
3 7 1098.88 24 11.69 1960 550 3.80 / 1199.26 2 2
4 8 -0.04 170 14.30 301 732 4.53 / 1199.99 2 3
Average= 5.38
(KJ/cycle)

Cycle 221 GMT 6/ 8/2022 15:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 25 14.25 453 161 0.16 / 1190.85 2 2
2 12 1106.16 154 10.28 1954 3093 3.25 / 1193.94 2 2
3 7 1095.60 24 11.71 1962 551 3.81 / 1194.50 2 2
4 13 41.40 44 14.22 368 230 4.04 / 1194.73 2 2
5 8 0.16 170 14.31 302 735 4.77 / 1195.46 2 6
Average= 5.38
(KJ/cycle)

Cycle 220 GMT 27/ 7/2022 22:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 25 14.27 449 160 0.16 / 1186.05 2 2
2 12 1104.24 154 10.32 1958 3112 3.27 / 1189.17 2 2
3 7 1093.08 24 11.75 1954 551 3.82 / 1189.72 2 2
4 13 37.60 44 14.24 364 228 4.05 / 1189.95 2 3
5 8 -0.24 170 14.31 306 744 4.80 / 1190.69 2 5
Average= 5.39
(KJ/cycle)

Cycle 219 GMT 18/ 7/2022 5:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 25 14.22 453 161 0.16 / 1178.89 2 2
2 12 1117.00 3 12.05 2021 73 0.23 / 1178.96 2 2
3 12 1976.52 154 10.22 3205 5044 5.28 / 1184.01 2 2
4 7 1965.00 24 11.15 3194 855 6.13 / 1184.86 2 2
5 13 95.24 44 14.15 462 288 6.42 / 1185.15 2 2
6 8 -0.04 170 14.35 306 746 7.17 / 1185.89 2 5
Average= 5.39
(KJ/cycle)

Cycle 218 GMT 17/ 7/2022 1:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 25 14.23 450 160 0.16 / 1174.39 2 2
2 12 1112.72 154 10.13 1956 3051 3.21 / 1177.44 2 2
3 7 1101.60 24 11.67 1970 552 3.76 / 1177.99 2 2
4 8 0.08 170 14.30 302 734 4.50 / 1178.73 2 4
Average= 5.38
(KJ/cycle)

Cycle 217 GMT 7/ 7/2022 8:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 25 14.20 455 162 0.16 / 1169.82 2 2
2 12 1115.84 154 10.26 1973 3117 3.28 / 1172.94 2 2
3 7 1105.08 24 11.69 1978 555 3.83 / 1173.49 2 2
4 8 0.00 170 14.30 303 737 4.57 / 1174.23 2 3
Average= 5.39
(KJ/cycle)

Cycle 216 GMT 27/ 6/2022 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 25 14.26 450 160 0.16 / 1165.27 2 2
2 12 1094.64 154 10.36 1939 3094 3.25 / 1168.37 2 2
3 7 1083.80 24 11.77 1951 551 3.81 / 1168.92 2 2
4 8 0.04 170 14.30 305 741 4.55 / 1169.66 2 3
Average= 5.39
(KJ/cycle)

Cycle 215 GMT 17/ 6/2022 21:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 25 14.22 453 161 0.16 / 1158.14 2 2
2 3 971.32 -1 15.10 0 0 0.00 / 1158.14 2 2
3 12 1139.48 3 11.99 2065 74 0.24 / 1158.21 2 2
4 12 1977.20 154 10.17 3202 5015 5.25 / 1163.23 2 2
5 7 1966.08 24 11.11 3192 851 6.10 / 1164.08 2 2
6 13 98.88 44 14.15 470 293 6.39 / 1164.37 2 2
7 8 0.00 170 14.35 304 742 7.14 / 1165.11 2 6
Average= 5.39
(KJ/cycle)

Cycle 214 GMT 16/ 6/2022 18:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 25 14.22 451 160 0.16 / 1153.39 2 2
2 12 1115.72 154 10.21 1968 3094 3.25 / 1156.48 2 2
3 7 1104.56 24 11.71 1977 556 3.81 / 1157.04 2 2
4 13 21.04 44 14.24 331 207 4.02 / 1157.24 2 2
5 8 -0.08 170 14.30 302 734 4.75 / 1157.98 2 8
Average= 5.39
(KJ/cycle)

Cycle 213 GMT 7/ 6/2022 1:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 25 14.22 455 162 0.16 / 1148.62 2 2
2 12 1123.56 154 10.21 1975 3105 3.27 / 1151.72 2 2
3 7 1112.36 24 11.73 1987 559 3.83 / 1152.28 2 2
4 13 21.20 44 14.25 330 207 4.03 / 1152.49 2 2
5 8 0.12 170 14.30 303 737 4.77 / 1153.23 2 7
Average= 5.39
(KJ/cycle)

Cycle 212 GMT 28/ 5/2022 7:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 25 14.26 447 159 0.16 / 1143.81 2 2
2 12 1104.44 154 10.36 1955 3119 3.28 / 1146.93 2 2
3 7 1093.12 24 11.79 1964 556 3.83 / 1147.49 2 2
4 13 40.68 44 14.22 367 230 4.06 / 1147.72 2 2
5 8 -0.20 170 14.31 304 740 4.80 / 1148.46 2 5
Average= 5.39
(KJ/cycle)

Cycle 211 GMT 18/ 5/2022 14:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 25 14.20 463 164 0.16 / 1136.65 2 2
2 12 1117.12 3 11.99 2029 73 0.24 / 1136.73 2 2
3 12 1982.80 154 10.17 3212 5031 5.27 / 1141.76 2 2
4 7 1971.60 24 11.18 3204 860 6.13 / 1142.62 2 2
5 13 100.48 44 14.13 473 294 6.42 / 1142.91 2 2
6 8 0.00 170 14.35 304 742 7.16 / 1143.65 2 6
Average= 5.39
(KJ/cycle)

Cycle 210 GMT 17/ 5/2022 11:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 25 14.19 457 162 0.16 / 1131.87 2 2
2 12 1120.44 154 10.17 1972 3089 3.25 / 1134.95 2 2
3 7 1109.20 24 11.73 1983 558 3.81 / 1135.51 2 2
4 13 46.84 44 14.18 378 236 4.04 / 1135.75 2 2
5 8 -0.12 170 14.28 305 740 4.79 / 1136.49 2 3
Average= 5.39
(KJ/cycle)

Cycle 209 GMT 7/ 5/2022 18:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 25 14.24 456 162 0.16 / 1127.10 2 2
2 12 1099.24 154 10.27 1944 3075 3.24 / 1130.18 2 2
3 7 1088.24 24 11.77 1953 552 3.79 / 1130.73 2 2
4 13 39.96 44 14.21 366 229 4.02 / 1130.96 2 2
5 8 -0.12 170 14.29 306 743 4.76 / 1131.70 2 7
Average= 5.39
(KJ/cycle)

Cycle 208 GMT 28/ 4/2022 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 25 14.26 445 159 0.16 / 1122.29 2 2
2 12 1119.52 154 10.25 1973 3114 3.27 / 1125.41 2 2
3 7 1108.80 24 11.78 1980 560 3.83 / 1125.97 2 2
4 13 44.84 44 14.20 378 236 4.07 / 1126.20 2 2
5 8 -0.04 170 14.31 304 740 4.81 / 1126.94 2 4
Average= 5.39
(KJ/cycle)

Cycle 207 GMT 18/ 4/2022 7:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 25 14.24 447 159 0.16 / 1115.18 2 2
2 12 1109.08 3 12.03 2012 73 0.23 / 1115.25 2 2
3 12 1972.40 154 10.16 3200 5007 5.24 / 1120.26 2 2
4 7 1960.64 24 11.14 3198 855 6.09 / 1121.11 2 2
5 13 84.44 44 14.15 447 278 6.37 / 1121.39 2 2
6 8 -0.04 170 14.35 304 742 7.11 / 1122.13 2 7
Average= 5.39
(KJ/cycle)

Cycle 206 GMT 17/ 4/2022 4:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 26 14.22 450 166 0.17 / 1110.44 2 2
2 3 958.36 -1 15.15 0 0 0.00 / 1110.44 2 2
3 12 1121.48 154 10.04 1969 3044 3.21 / 1113.49 2 2
4 7 1110.84 24 11.75 1983 559 3.77 / 1114.05 2 2
5 13 50.56 44 14.18 385 240 4.01 / 1114.29 2 2
6 8 -0.04 170 14.30 302 734 4.74 / 1115.02 2 4
Average= 5.39
(KJ/cycle)

Cycle 205 GMT 7/ 4/2022 11: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 25 14.17 442 157 0.16 / 1105.69 2 2
2 12 1102.56 154 10.21 1947 3061 3.22 / 1108.75 2 2
3 7 1091.92 24 11.77 1958 553 3.77 / 1109.31 2 2
4 13 35.60 44 14.19 360 225 4.00 / 1109.53 2 2
5 8 -0.08 170 14.28 307 745 4.74 / 1110.28 2 6
Average= 5.39
(KJ/cycle)

Cycle 204 GMT 28/ 3/2022 17:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 25 14.21 452 161 0.16 / 1100.90 2 2
2 12 1114.00 154 10.23 1964 3094 3.25 / 1103.99 2 2
3 7 1102.64 24 11.82 1977 561 3.82 / 1104.55 2 2
4 13 42.20 44 14.21 372 233 4.05 / 1104.79 2 2
5 8 -0.16 170 14.30 308 749 4.80 / 1105.54 2 7
Average= 5.39
(KJ/cycle)

Cycle 203 GMT 19/ 3/2022 0:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 25 14.22 454 161 0.16 / 1093.80 2 2
2 12 1110.88 3 11.98 2022 73 0.23 / 1093.88 2 2
3 12 1957.68 154 10.16 3187 4987 5.22 / 1098.86 2 2
4 7 1945.72 24 11.25 3166 855 6.08 / 1099.72 2 2
5 13 75.96 44 14.16 435 271 6.35 / 1099.99 2 2
6 8 -0.04 170 14.34 307 748 7.09 / 1100.74 2 5
Average= 5.40
(KJ/cycle)

Cycle 202 GMT 17/ 3/2022 21:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 26 14.17 467 172 0.17 / 1089.05 2 2
2 12 1125.72 154 10.03 1978 3055 3.23 / 1092.11 2 2
3 7 1115.20 24 11.78 1996 564 3.79 / 1092.67 2 2
4 13 47.12 44 14.18 377 235 4.03 / 1092.91 2 2
5 8 -0.04 170 14.29 303 736 4.76 / 1093.64 2 6
Average= 5.39
(KJ/cycle)

Cycle 201 GMT 8/ 3/2022 3:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 25 14.18 448 159 0.16 / 1084.34 2 2
2 12 1086.96 154 10.21 1930 3035 3.19 / 1087.37 2 2
3 7 1075.96 24 11.83 1942 551 3.74 / 1087.92 2 2
4 13 16.80 44 14.23 333 208 3.95 / 1088.13 2 2
5 8 -0.04 170 14.27 308 747 4.70 / 1088.88 2 7
Average= 5.39
(KJ/cycle)

Cycle 200 GMT 26/ 2/2022 10:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 25 14.25 451 161 0.16 / 1079.55 2 2
2 12 1113.40 154 10.28 1967 3114 3.27 / 1082.67 2 2
3 7 1102.52 24 11.85 1967 559 3.83 / 1083.23 2 2
4 13 16.96 44 14.26 327 205 4.04 / 1083.43 2 2
5 8 -0.16 170 14.29 308 748 4.79 / 1084.18 2 11
Average= 5.39
(KJ/cycle)

Cycle 199 GMT 16/ 2/2022 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 25 14.23 452 161 0.16 / 1072.45 2 2
2 12 1112.16 3 11.95 2009 72 0.23 / 1072.52 2 2
3 12 1972.56 154 10.11 3198 4979 5.21 / 1077.50 2 2
4 7 1960.88 24 11.24 3204 864 6.08 / 1078.36 2 2
5 13 92.40 44 14.13 460 286 6.36 / 1078.65 2 2
6 8 0.00 170 14.35 305 744 7.11 / 1079.39 2 7
Average= 5.40
(KJ/cycle)

Cycle 198 GMT 15/ 2/2022 14: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 25 14.26 448 160 0.16 / 1067.66 2 2
2 3 1029.84 1 12.60 1921 24 0.18 / 1067.68 2 2
3 12 1123.40 154 10.22 1974 3107 3.29 / 1070.79 2 2
4 7 1112.16 24 11.80 1979 560 3.85 / 1071.35 2 2
5 13 20.88 44 14.23 326 204 4.06 / 1071.55 2 2
6 8 -0.08 170 14.28 303 736 4.79 / 1072.29 2 3
Average= 5.39
(KJ/cycle)

Cycle 197 GMT 5/ 2/2022 20:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 25 14.25 457 163 0.16 / 1063.73 2 2
2 12 1129.00 65 10.45 1980 1345 1.51 / 1065.07 2 2
3 7 1124.52 24 12.05 2013 582 2.09 / 1065.65 2 2
4 13 714.80 44 13.24 1431 834 2.92 / 1066.49 2 2
5 13 94.00 44 14.16 448 279 3.20 / 1066.77 2 2
6 8 0.00 170 14.32 299 728 3.93 / 1067.50 2 6
Average= 5.39
(KJ/cycle)

Cycle 196 GMT 27/ 1/2022 2:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 25 14.26 464 165 0.17 / 1059.79 2 2
2 12 1134.32 65 10.68 1999 1388 1.55 / 1061.18 2 2
3 7 1129.56 24 12.09 2027 588 2.14 / 1061.77 2 2
4 13 710.36 44 13.27 1429 834 2.98 / 1062.60 2 2
5 13 49.52 44 14.28 375 236 3.21 / 1062.84 2 2
6 8 -0.04 170 14.35 297 725 3.94 / 1063.56 2 4
Average= 5.40
(KJ/cycle)

Cycle 195 GMT 17/ 1/2022 8:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 25 14.24 443 158 0.16 / 1054.34 2 2
2 12 1131.28 3 12.23 2045 75 0.23 / 1054.41 2 2
3 12 1986.44 65 10.39 3212 2169 2.40 / 1056.58 2 2
4 7 1978.88 24 11.22 3223 868 3.27 / 1057.45 2 2
5 13 1077.16 44 12.89 1952 1107 4.38 / 1058.56 2 2
6 13 128.32 44 14.13 521 324 4.70 / 1058.88 2 2
7 8 -0.08 170 14.35 306 746 5.45 / 1059.63 2 4
Average= 5.41
(KJ/cycle)

Cycle 194 GMT 16/ 1/2022 4:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 25 14.19 447 159 0.16 / 1050.57 2 2
2 12 1120.16 65 10.33 1965 1319 1.48 / 1051.89 2 2
3 7 1116.52 24 12.01 1999 576 2.05 / 1052.47 2 2
4 13 593.84 44 13.36 1257 739 2.79 / 1053.21 2 2
5 13 54.28 44 14.22 382 239 3.03 / 1053.45 2 2
6 8 -0.04 170 14.30 303 737 3.77 / 1054.18 2 6
Average= 5.41
(KJ/cycle)

Cycle 193 GMT 6/ 1/2022 10:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 25 14.24 456 162 0.16 / 1046.71 2 2
2 12 1114.04 65 10.50 1968 1343 1.51 / 1048.05 2 2
3 7 1108.80 24 12.06 1990 576 2.08 / 1048.63 2 2
4 13 691.20 44 13.26 1399 816 2.90 / 1049.45 2 2
5 13 41.04 44 14.27 362 227 3.13 / 1049.67 2 2
6 8 -0.04 170 14.32 304 740 3.87 / 1050.41 2 3
Average= 5.41
(KJ/cycle)

Cycle 192 GMT 27/12/2021 16:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 25 14.31 449 161 0.16 / 1042.90 2 2
2 12 1098.56 65 10.99 1946 1390 1.55 / 1044.30 2 2
3 7 1093.16 24 12.16 1965 573 2.12 / 1044.87 2 2
4 13 551.72 44 13.48 1188 705 2.83 / 1045.57 2 2
5 13 38.40 44 14.28 362 227 3.06 / 1045.80 2 2
6 8 -0.16 170 14.32 307 747 3.80 / 1046.55 2 9
Average= 5.42
(KJ/cycle)

Cycle 191 GMT 17/12/2021 23: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 22 14.32 460 145 0.14 / 1037.42 2 2
2 10 1018.76 4 13.34 1892 101 0.25 / 1037.52 2 2
3 12 1108.24 5 12.76 2016 129 0.37 / 1037.65 2 2
4 12 1918.96 65 11.11 3137 2265 2.64 / 1039.91 2 2
5 7 1910.36 24 11.46 3142 864 3.50 / 1040.78 2 2
6 13 835.96 44 13.22 1622 943 4.45 / 1041.72 2 2
7 13 78.56 44 14.26 436 274 4.72 / 1042.00 2 2
8 8 -0.04 170 14.40 306 749 5.47 / 1042.74 2 5
Average= 5.43
(KJ/cycle)

Cycle 190 GMT 16/12/2021 19:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 25 14.26 455 162 0.16 / 1030.98 2 2
2 12 1115.96 3 8.53 1959 50 0.21 / 1031.03 2 2
3 12 2007.96 68 8.78 3161 1887 2.10 / 1032.92 2 2
4 12 1999.28 65 9.00 3192 1867 3.97 / 1034.78 2 2
5 7 1990.60 24 11.22 3233 871 4.84 / 1035.65 2 2
6 13 498.84 44 13.58 1111 664 5.50 / 1036.32 2 3
7 13 17.16 44 14.38 329 208 5.71 / 1036.52 2 2
8 8 0.04 170 14.40 306 749 6.46 / 1037.27 2 12
Average= 5.43
(KJ/cycle)

Cycle 189 GMT 6/12/2021 19:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 26 14.28 448 166 0.17 / 1024.52 2 2
2 3 941.96 -1 15.28 0 0 0.00 / 1024.52 2 2
3 12 1114.40 3 8.71 1943 51 0.22 / 1024.57 2 2
4 12 2004.80 68 8.87 3145 1897 2.11 / 1026.46 2 2
5 12 1993.68 65 8.99 3185 1861 3.98 / 1028.33 2 2
6 7 1984.16 24 11.24 3204 864 4.84 / 1029.19 2 2
7 13 483.40 44 13.59 1096 655 5.49 / 1029.85 2 3
8 13 27.88 44 14.34 352 222 5.72 / 1030.07 2 2
9 8 -0.04 170 14.38 306 748 6.47 / 1030.82 2 5
Average= 5.43
(KJ/cycle)

Cycle 188 GMT 26/11/2021 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 25 14.31 465 166 0.17 / 1017.86 2 2
2 3 1033.20 1 12.96 1930 25 0.19 / 1017.89 2 2
3 12 1140.72 3 8.17 1985 49 0.24 / 1017.94 2 2
4 12 2005.44 68 8.95 3150 1917 2.16 / 1019.85 2 2
5 12 1995.60 65 9.04 3185 1872 4.03 / 1021.72 2 2
6 7 1986.56 24 11.29 3216 871 4.90 / 1022.60 2 2
7 13 487.64 44 13.59 1091 652 5.55 / 1023.25 2 3
8 13 26.28 44 14.35 341 215 5.77 / 1023.46 2 2
9 8 -0.16 170 14.37 309 755 6.52 / 1024.22 2 3
10 14 -0.16 30 14.41 306 132 6.65 / 1024.35 2 6
Average= 5.42
(KJ/cycle)

Cycle 187 GMT 16/11/2021 20:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 25 14.31 460 165 0.16 / 1011.54 2 2
2 3 969.64 -1 15.24 0 0 0.00 / 1011.54 2 2
3 3 1021.80 1 12.69 1931 25 0.19 / 1011.57 2 2
4 12 1131.08 3 9.82 1995 59 0.25 / 1011.63 2 2
5 12 2002.20 68 9.01 3153 1932 2.18 / 1013.56 2 2
6 12 1990.68 65 8.95 3179 1849 4.03 / 1015.41 2 2
7 7 1981.04 24 11.25 3220 869 4.90 / 1016.28 2 2
8 13 490.64 44 13.57 1109 662 5.56 / 1016.94 2 2
9 8 0.04 170 14.38 310 758 6.32 / 1017.70 2 5
Average= 5.41
(KJ/cycle)

Cycle 186 GMT 6/11/2021 21: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 25 14.28 468 167 0.17 / 1005.63 2 2
2 12 2001.36 65 9.00 3125 1828 2.00 / 1007.46 2 2
3 7 1997.80 24 10.90 3223 843 2.84 / 1008.30 2 2
4 13 1578.52 44 12.35 2666 1449 4.29 / 1009.75 2 2
5 13 457.56 44 13.61 1053 631 4.92 / 1010.38 2 3
6 13 45.04 44 14.28 382 240 5.16 / 1010.62 2 3
7 8 -0.20 170 14.35 310 756 5.91 / 1011.38 2 7
Average= 5.41
(KJ/cycle)

Cycle 185 GMT 27/10/2021 21:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 25 14.28 458 164 0.16 / 1000.09 2 2
2 12 2001.60 65 8.94 3115 1810 1.97 / 1001.90 2 2
3 7 1998.60 24 10.90 3231 845 2.82 / 1002.75 2 2
4 13 1570.08 44 12.37 2665 1451 4.27 / 1004.20 2 2
5 13 315.64 44 13.80 836 508 4.78 / 1004.71 2 2
6 8 0.12 170 14.36 310 757 5.53 / 1005.46 2 4
Average= 5.41
(KJ/cycle)

Cycle 184 GMT 17/10/2021 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 25 14.28 471 168 0.17 / 994.57 2 2
2 12 2005.24 65 9.04 3132 1840 2.01 / 996.41 2 2
3 7 2002.12 24 10.86 3220 839 2.85 / 997.25 2 2
4 13 1447.36 44 12.50 2487 1368 4.22 / 998.62 2 2
5 13 371.16 44 13.73 925 559 4.77 / 999.17 2 2
6 8 -0.04 170 14.37 309 755 5.53 / 999.93 2 5
Average= 5.41
(KJ/cycle)

Cycle 183 GMT 7/10/2021 21:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 25 14.32 461 165 0.17 / 988.77 2 2
2 12 1998.84 63 9.20 3141 1821 1.99 / 990.59 2 2
3 7 1995.44 24 10.89 3203 837 2.82 / 991.43 2 2
4 13 1563.48 42 12.43 2660 1389 4.21 / 992.82 2 2
5 13 457.04 42 13.63 1051 602 4.81 / 993.42 2 2
6 13 48.44 42 14.30 377 226 5.04 / 993.64 2 2
7 8 -0.04 170 14.36 310 757 5.80 / 994.40 2 8
Average= 5.40
(KJ/cycle)

Cycle 182 GMT 27/ 9/2021 22:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 25 14.34 464 166 0.17 / 983.15 2 2
2 12 2002.36 63 9.18 3129 1810 1.98 / 984.96 2 2
3 7 1999.00 24 10.91 3235 847 2.82 / 985.80 2 2
4 13 1447.44 42 12.55 2487 1311 4.13 / 987.12 2 2
5 13 377.84 42 13.73 929 536 4.67 / 987.65 2 3
6 13 20.12 42 14.36 340 205 4.87 / 987.86 2 2
7 8 -0.16 170 14.37 306 748 5.62 / 988.60 2 7
Average= 5.40
(KJ/cycle)

Cycle 181 GMT 17/ 9/2021 22:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 25 14.32 459 164 0.16 / 977.61 2 2
2 12 2000.04 63 9.15 3125 1801 1.97 / 979.41 2 2
3 7 1996.80 24 10.90 3219 842 2.81 / 980.25 2 2
4 13 1576.56 34 12.63 2665 1144 3.95 / 981.40 2 2
5 13 662.36 34 13.47 1368 627 4.58 / 982.02 2 2
6 13 81.60 34 14.27 430 209 4.79 / 982.23 2 2
7 8 0.08 170 14.38 307 750 5.54 / 982.98 2 6
Average= 5.40
(KJ/cycle)

Cycle 180 GMT 7/ 9/2021 22:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 25 14.33 454 163 0.16 / 972.21 2 2
2 12 2001.16 63 9.18 3141 1817 1.98 / 974.02 2 2
3 7 1998.00 24 10.94 3213 844 2.82 / 974.87 2 2
4 13 1441.76 34 12.74 2478 1073 3.90 / 975.94 2 2
5 13 549.60 34 13.57 1209 558 4.45 / 976.50 2 2
6 13 59.08 34 14.31 404 197 4.65 / 976.69 2 2
7 8 0.08 170 14.38 307 750 5.40 / 977.44 2 5
Average= 5.40
(KJ/cycle)

Cycle 179 GMT 28/ 8/2021 22:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 25 14.31 461 165 0.16 / 966.67 2 2
2 12 2000.12 51 9.31 3116 1480 1.64 / 968.15 2 2
3 7 1997.44 24 10.98 3244 855 2.50 / 969.00 2 2
4 13 1723.40 34 12.43 2879 1217 3.72 / 970.22 2 2
5 13 961.44 34 13.17 1809 810 4.53 / 971.03 2 2
6 13 135.72 34 14.16 533 257 4.78 / 971.29 2 2
7 8 0.00 170 14.37 309 755 5.54 / 972.04 2 4
Average= 5.40
(KJ/cycle)

Cycle 178 GMT 18/ 8/2021 22:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 25 14.31 454 162 0.16 / 961.20 2 2
2 12 1999.40 51 9.37 3145 1503 1.67 / 962.70 2 2
3 7 1995.96 24 10.98 3227 850 2.52 / 963.55 2 2
4 13 1714.00 34 12.45 2859 1210 3.73 / 964.77 2 2
5 13 806.68 34 13.32 1579 715 4.44 / 965.48 2 2
6 13 151.56 34 14.10 560 268 4.71 / 965.75 2 3
7 8 -0.08 170 14.36 310 757 5.47 / 966.51 2 4
Average= 5.40
(KJ/cycle)

Cycle 177 GMT 8/ 8/2021 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 25 14.33 454 163 0.16 / 955.84 2 2
2 12 2000.32 51 9.47 3143 1518 1.68 / 957.36 2 2
3 7 1997.04 24 10.97 3247 855 2.54 / 958.22 2 2
4 13 1712.28 34 12.44 2858 1209 3.74 / 959.43 2 2
5 13 668.32 34 13.45 1377 630 4.37 / 960.06 2 3
6 13 100.56 34 14.20 474 229 4.60 / 960.28 2 2
7 8 0.08 170 14.36 309 754 5.36 / 961.04 2 6
Average= 5.40
(KJ/cycle)

Cycle 176 GMT 29/ 7/2021 23:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 25 14.31 465 166 0.17 / 950.68 2 2
2 12 2002.84 51 9.41 3129 1502 1.67 / 952.19 2 2
3 7 1999.96 24 11.00 3243 856 2.52 / 953.04 2 2
4 13 1467.64 34 12.69 2518 1086 3.61 / 954.13 2 2
5 13 611.40 34 13.50 1291 593 4.20 / 954.72 2 2
6 13 70.52 34 14.25 422 204 4.41 / 954.93 2 2
7 8 0.08 170 14.35 310 756 5.16 / 955.68 2 6
Average= 5.40
(KJ/cycle)

Cycle 175 GMT 19/ 7/2021 23:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 26 14.30 464 173 0.17 / 945.37 2 2
2 12 2000.60 51 9.36 3127 1493 1.67 / 946.86 2 2
3 7 1997.92 24 11.02 3229 854 2.52 / 947.72 2 2
4 13 1600.84 34 12.57 2701 1154 3.67 / 948.87 2 2
5 13 718.72 34 13.40 1447 659 4.33 / 949.53 2 2
6 13 103.84 34 14.18 475 229 4.56 / 949.76 2 3
7 8 0.04 170 14.33 312 760 5.32 / 950.52 2 4
Average= 5.40
(KJ/cycle)

Cycle 174 GMT 9/ 7/2021 23:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 25 14.34 464 166 0.17 / 940.03 2 2
2 3 1027.28 1 13.05 1936 25 0.19 / 940.05 2 2
3 12 2004.68 51 9.35 3123 1489 1.68 / 941.54 2 2
4 7 2001.88 24 11.00 3249 858 2.54 / 942.40 2 2
5 13 1593.68 34 12.57 2701 1154 3.69 / 943.55 2 2
6 13 715.52 34 13.40 1445 658 4.35 / 944.21 2 2
7 13 103.08 34 14.18 476 229 4.58 / 944.44 2 2
8 8 -0.28 170 14.34 310 756 5.34 / 945.20 2 6
Average= 5.40
(KJ/cycle)

Cycle 173 GMT 29/ 6/2021 23:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 25 14.32 455 163 0.16 / 934.53 2 2
2 12 2000.68 51 9.38 3112 1489 1.65 / 936.02 2 2
3 7 1997.40 24 11.02 3231 855 2.51 / 936.87 2 2
4 13 1712.48 34 12.47 2851 1209 3.71 / 938.08 2 2
5 13 676.52 34 13.44 1391 636 4.35 / 938.71 2 2
6 13 99.40 34 14.21 468 226 4.58 / 938.94 2 3
7 13 22.56 34 14.35 344 168 4.74 / 939.11 2 2
8 8 -0.04 170 14.35 308 751 5.50 / 939.86 2 10
Average= 5.40
(KJ/cycle)

Cycle 172 GMT 19/ 6/2021 23:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 25 14.35 452 162 0.16 / 929.12 2 2
2 12 2002.36 51 9.38 3130 1497 1.66 / 930.62 2 2
3 7 1999.40 24 11.05 3226 856 2.52 / 931.47 2 2
4 13 1725.84 34 12.43 2876 1215 3.73 / 932.69 2 2
5 13 802.96 34 13.32 1571 711 4.44 / 933.40 2 2
6 13 80.84 34 14.27 431 209 4.65 / 933.61 2 2
7 8 0.04 170 14.37 309 755 5.41 / 934.36 2 4
Average= 5.40
(KJ/cycle)

Cycle 171 GMT 9/ 6/2021 23:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 25 14.36 455 163 0.16 / 923.86 2 2
2 12 2001.72 51 9.16 3100 1448 1.61 / 925.31 2 2
3 7 1999.08 24 11.08 3248 864 2.48 / 926.18 2 2
4 13 1576.48 34 12.60 2659 1139 3.61 / 927.32 2 2
5 13 707.28 34 13.41 1429 652 4.27 / 927.97 2 2
6 13 97.88 34 14.21 474 229 4.49 / 928.20 2 2
7 8 -0.08 170 14.36 312 762 5.26 / 928.96 2 5
Average= 5.40
(KJ/cycle)

Cycle 170 GMT 31/ 5/2021 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 25 14.30 457 163 0.16 / 918.48 2 2
2 12 1999.84 51 9.38 3120 1493 1.66 / 919.97 2 2
3 7 1996.64 24 11.02 3238 856 2.51 / 920.83 2 2
4 13 1708.16 34 12.46 2846 1206 3.72 / 922.03 2 2
5 13 787.96 34 13.32 1556 705 4.42 / 922.74 2 2
6 13 79.76 34 14.26 432 209 4.63 / 922.95 2 2
7 8 0.12 170 14.39 308 753 5.39 / 923.70 2 4
Average= 5.40
(KJ/cycle)

Cycle 169 GMT 21/ 5/2021 0:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 25 14.36 456 164 0.16 / 913.19 2 2
2 12 2003.32 51 9.37 3125 1493 1.66 / 914.68 2 2
3 7 2000.68 24 11.10 3250 866 2.52 / 915.55 2 2
4 13 1583.32 34 12.58 2685 1148 3.67 / 916.70 2 2
5 13 683.44 34 13.43 1402 640 4.31 / 917.34 2 2
6 13 90.28 34 14.24 451 218 4.53 / 917.56 2 2
7 8 0.12 170 14.36 311 759 5.29 / 918.32 2 8
Average= 5.40
(KJ/cycle)

Cycle 168 GMT 11/ 5/2021 0:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 25 14.35 463 166 0.17 / 907.89 2 2
2 12 2004.28 51 9.27 3133 1481 1.65 / 909.37 2 2
3 7 2001.36 24 11.07 3236 860 2.51 / 910.23 2 2
4 13 1578.88 34 12.59 2683 1148 3.66 / 911.38 2 2
5 13 704.40 34 13.40 1432 652 4.31 / 912.04 2 2
6 13 98.88 34 14.21 476 230 4.54 / 912.27 2 2
7 8 -0.24 170 14.36 312 762 5.30 / 913.03 2 5
Average= 5.40
(KJ/cycle)

Cycle 167 GMT 1/ 5/2021 0:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 25 14.39 449 162 0.16 / 902.64 2 2
2 12 2001.08 51 9.47 3120 1507 1.67 / 904.15 2 2
3 7 1998.00 24 11.06 3220 855 2.52 / 905.00 2 2
4 13 1577.00 34 12.61 2667 1143 3.67 / 906.15 2 2
5 13 680.16 34 13.43 1400 639 4.31 / 906.79 2 2
6 13 53.88 34 14.35 384 187 4.49 / 906.97 2 2
7 8 0.12 170 14.39 308 753 5.25 / 907.73 2 6
Average= 5.40
(KJ/cycle)

Cycle 166 GMT 21/ 4/2021 0:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 25 14.35 451 162 0.16 / 897.40 2 2
2 12 2000.76 51 9.33 3134 1491 1.65 / 898.89 2 2
3 7 1998.16 24 11.11 3245 865 2.52 / 899.76 2 2
4 13 1579.80 34 12.61 2662 1141 3.66 / 900.90 2 2
5 13 696.04 34 13.42 1420 648 4.31 / 901.55 2 2
6 13 55.96 34 14.32 389 189 4.50 / 901.73 2 2
7 8 0.04 170 14.39 305 746 5.24 / 902.48 2 3
Average= 5.40
(KJ/cycle)

Cycle 165 GMT 11/ 4/2021 1: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 25 14.40 452 163 0.16 / 892.04 2 2
2 12 2002.24 51 9.36 3146 1502 1.66 / 893.54 2 2
3 7 1999.28 24 11.11 3236 863 2.53 / 894.41 2 2
4 13 1582.28 34 12.59 2692 1152 3.68 / 895.56 2 2
5 13 820.60 34 13.30 1603 725 4.40 / 896.28 2 2
6 13 79.96 34 14.27 433 210 4.61 / 896.49 2 2
7 8 -0.04 170 14.39 304 744 5.36 / 897.24 2 3
Average= 5.41
(KJ/cycle)

Cycle 164 GMT 1/ 4/2021 1:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 25 14.40 457 165 0.16 / 886.62 2 2
2 3 1030.24 1 13.08 1930 25 0.19 / 886.65 2 2
3 12 2000.12 50 9.49 3102 1472 1.66 / 888.12 2 2
4 7 1997.40 24 11.15 3253 871 2.53 / 888.99 2 2
5 13 1730.12 34 12.49 2876 1221 3.75 / 890.21 2 2
6 13 813.32 34 13.32 1587 719 4.47 / 890.93 2 2
7 13 86.16 34 14.26 439 213 4.69 / 891.14 2 2
8 8 -0.04 170 14.40 300 734 5.42 / 891.88 2 10
Average= 5.41
(KJ/cycle)

Cycle 163 GMT 22/ 3/2021 1:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 25 14.35 458 164 0.16 / 881.33 2 2
2 12 2004.44 50 9.38 3136 1471 1.64 / 882.80 2 2
3 7 2001.84 24 11.12 3244 866 2.50 / 883.67 2 2
4 13 1597.24 34 12.61 2688 1152 3.65 / 884.82 2 2
5 13 714.36 34 13.41 1441 657 4.31 / 885.48 2 2
6 13 107.92 34 14.20 482 233 4.54 / 885.71 2 2
7 8 0.12 170 14.38 306 748 5.29 / 886.46 2 7
Average= 5.41
(KJ/cycle)

Cycle 162 GMT 12/ 3/2021 1:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 25 14.34 454 163 0.16 / 875.67 2 2
2 12 2003.24 50 9.43 3116 1469 1.63 / 877.14 2 2
3 7 2000.48 24 11.17 3220 863 2.50 / 878.00 2 2
4 13 1592.40 48 12.33 2682 1587 4.08 / 879.59 2 2
5 13 345.68 48 13.76 880 581 4.66 / 880.17 2 3
6 13 30.44 48 14.34 350 241 4.90 / 880.41 2 2
7 8 -0.04 170 14.35 311 759 5.66 / 881.17 2 5
Average= 5.41
(KJ/cycle)

Cycle 161 GMT 2/ 3/2021 1:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 25 14.34 457 164 0.16 / 869.88 2 2
2 3 967.16 -1 15.28 0 0 0.00 / 869.88 2 2
3 3 1025.28 1 12.95 1942 25 0.19 / 869.91 2 2
4 12 2000.64 50 9.39 3109 1460 1.65 / 871.37 2 2
5 7 1997.60 24 11.14 3221 861 2.51 / 872.23 2 2
6 13 1579.52 48 12.37 2657 1578 4.09 / 873.81 2 2
7 13 463.92 48 13.59 1061 692 4.78 / 874.50 2 2
8 13 43.32 48 14.31 370 254 5.03 / 874.75 2 3
9 8 -0.16 170 14.34 309 753 5.79 / 875.51 2 6
Average= 5.40
(KJ/cycle)

Cycle 160 GMT 20/ 2/2021 1:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 25 14.35 448 161 0.16 / 864.11 2 2
2 12 2001.72 50 9.59 3108 1490 1.65 / 865.60 2 2
3 7 1998.68 24 11.15 3232 865 2.52 / 866.46 2 2
4 13 1582.04 48 12.35 2671 1583 4.10 / 868.05 2 2
5 13 456.68 48 13.60 1049 685 4.78 / 868.73 2 3
6 13 18.96 48 14.37 327 226 5.01 / 868.96 2 3
7 8 -0.16 170 14.33 313 762 5.77 / 869.72 2 5
Average= 5.40
(KJ/cycle)

Cycle 159 GMT 10/ 2/2021 2:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 25 14.39 457 164 0.16 / 858.68 2 2
2 12 2000.36 50 9.63 3123 1504 1.67 / 860.19 2 2
3 7 1997.20 24 11.18 3238 869 2.54 / 861.06 2 2
4 13 1578.16 48 12.35 2667 1581 4.12 / 862.64 2 2
5 13 324.20 48 13.79 846 560 4.68 / 863.20 2 3
6 8 -0.12 170 14.35 307 749 5.43 / 863.95 2 4
Average= 5.40
(KJ/cycle)

Cycle 158 GMT 31/ 1/2021 2:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 25 14.42 449 162 0.16 / 853.32 2 2
2 12 2004.76 50 9.57 3115 1491 1.65 / 854.81 2 2
3 7 2001.88 24 11.19 3236 869 2.52 / 855.68 2 2
4 13 1460.68 48 12.49 2486 1490 4.01 / 857.17 2 2
5 13 351.24 48 13.74 897 592 4.60 / 857.76 2 3
6 8 -0.12 170 14.35 311 759 5.36 / 858.52 2 4
Average= 5.40
(KJ/cycle)

Cycle 157 GMT 21/ 1/2021 2:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 25 14.42 460 166 0.17 / 847.81 2 2
2 12 2004.24 50 9.45 3119 1474 1.64 / 849.28 2 2
3 7 2001.72 24 11.27 3225 872 2.51 / 850.16 2 2
4 13 1737.04 48 12.19 2889 1690 4.20 / 851.85 2 2
5 13 327.16 48 13.80 848 562 4.76 / 852.41 2 3
6 8 -0.12 170 14.38 306 748 5.51 / 853.16 2 11
Average= 5.40
(KJ/cycle)

Cycle 156 GMT 11/ 1/2021 3: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 27 14.37 455 177 0.18 / 842.58 2 2
2 3 912.32 -2 15.30 0 0 0.00 / 842.58 2 2
3 12 2002.76 50 9.39 3076 1444 1.62 / 844.03 2 2
4 7 1999.88 24 11.25 3235 873 2.49 / 844.90 2 2
5 13 1477.72 48 12.50 2512 1507 4.00 / 846.41 2 2
6 13 258.20 48 13.93 729 487 4.49 / 846.90 2 2
7 8 0.08 170 14.39 306 749 5.24 / 847.65 2 9
Average= 5.40
(KJ/cycle)

Cycle 155 GMT 1/ 1/2021 3:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 26 14.38 480 179 0.18 / 836.99 2 2
2 3 1040.28 1 13.19 1945 26 0.21 / 837.01 2 2
3 3 1026.96 1 12.97 1922 25 0.23 / 837.04 2 2
4 12 2002.68 50 9.51 3081 1465 1.70 / 838.50 2 2
5 7 1999.84 24 11.28 3237 876 2.57 / 839.38 2 2
6 13 1583.04 48 12.39 2668 1587 4.16 / 840.97 2 2
7 13 467.48 48 13.62 1063 695 4.85 / 841.66 2 2
8 8 -0.08 170 14.37 305 745 5.60 / 842.41 2 6
Average= 5.40
(KJ/cycle)

Cycle 154 GMT 22/12/2020 3:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 27 14.39 457 178 0.18 / 831.45 2 2
2 3 958.36 -1 15.31 0 0 0.00 / 831.45 2 2
3 12 2000.28 50 9.45 3070 1451 1.63 / 832.90 2 2
4 7 1997.28 24 11.26 3218 870 2.50 / 833.77 2 2
5 13 1582.84 48 12.39 2662 1583 4.08 / 835.35 2 2
6 13 492.88 48 13.59 1096 715 4.80 / 836.06 2 3
7 8 -0.04 170 14.38 305 746 5.54 / 836.81 2 2
Average= 5.40
(KJ/cycle)

Cycle 153 GMT 12/12/2020 3:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 27 14.38 462 179 0.18 / 825.82 2 2
2 3 972.24 -1 15.30 0 0 0.00 / 825.82 2 2
3 3 1024.96 1 12.91 1929 25 0.20 / 825.84 2 2
4 12 2001.16 50 9.46 3067 1451 1.65 / 827.30 2 2
5 7 1998.52 24 11.28 3245 878 2.53 / 828.17 2 2
6 13 1720.84 48 12.25 2854 1678 4.21 / 829.85 2 2
7 13 450.08 48 13.64 1035 678 4.89 / 830.53 2 2
8 8 0.04 170 14.39 302 739 5.63 / 831.27 2 7
Average= 5.40
(KJ/cycle)

Cycle 152 GMT 2/12/2020 3:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 26 14.42 459 172 0.17 / 820.04 2 2
2 3 1037.52 1 13.13 1943 26 0.20 / 820.06 2 2
3 3 1021.64 1 12.69 1944 25 0.22 / 820.09 2 2
4 12 2001.44 50 9.59 3092 1483 1.70 / 821.57 2 2
5 7 1998.40 24 11.28 3231 875 2.58 / 822.44 2 2
6 13 1717.52 48 12.24 2858 1679 4.26 / 824.12 2 2
7 13 561.08 48 13.49 1210 783 5.04 / 824.91 2 2
8 8 -0.04 170 14.39 300 734 5.78 / 825.64 2 3
Average= 5.40
(KJ/cycle)

Cycle 151 GMT 22/11/2020 4:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 26 14.43 462 173 0.17 / 814.53 2 2
2 12 2004.24 50 9.54 3098 1478 1.65 / 816.01 2 2
3 7 2001.44 24 11.26 3232 873 2.52 / 816.88 2 2
4 13 1722.40 48 12.23 2861 1680 4.20 / 818.56 2 2
5 13 318.52 48 13.82 836 555 4.76 / 819.12 2 2
6 8 -0.08 170 14.37 306 748 5.51 / 819.86 2 4
Average= 5.39
(KJ/cycle)

Cycle 150 GMT 12/11/2020 4:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 26 14.42 465 174 0.17 / 809.02 2 2
2 12 2000.92 50 9.53 3088 1471 1.65 / 810.49 2 2
3 7 1997.80 24 11.25 3230 872 2.52 / 811.36 2 2
4 13 1726.24 48 12.22 2865 1680 4.20 / 813.04 2 2
5 13 334.00 48 13.80 858 568 4.77 / 813.61 2 2
6 8 0.00 170 14.38 307 750 5.52 / 814.36 2 6
Average= 5.39
(KJ/cycle)

Cycle 149 GMT 2/11/2020 4:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 26 14.40 450 168 0.17 / 803.47 2 2
2 12 2005.84 50 9.53 3093 1474 1.64 / 804.95 2 2
3 7 2003.16 24 11.27 3250 879 2.52 / 805.83 2 2
4 13 1727.96 36 12.46 2882 1293 3.81 / 807.12 2 2
5 13 805.92 36 13.31 1577 756 4.57 / 807.87 2 2
6 13 85.88 36 14.27 445 229 4.80 / 808.10 2 2
7 8 -0.04 170 14.39 302 739 5.54 / 808.84 2 6
Average= 5.39
(KJ/cycle)

Cycle 148 GMT 23/10/2020 5: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 25 14.44 450 162 0.16 / 798.06 2 2
2 3 1022.60 1 12.87 1951 25 0.19 / 798.09 2 2
3 12 2004.80 50 9.64 3097 1493 1.68 / 799.58 2 2
4 7 2002.16 24 11.27 3236 875 2.56 / 800.45 2 2
5 13 1590.04 36 12.59 2693 1221 3.78 / 801.68 2 2
6 13 666.00 36 13.45 1365 661 4.44 / 802.34 2 2
7 13 82.60 36 14.28 428 220 4.66 / 802.56 2 2
8 8 -0.04 170 14.37 306 748 5.40 / 803.30 2 8
Average= 5.39
(KJ/cycle)

Cycle 147 GMT 13/10/2020 5:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 26 14.43 454 170 0.17 / 792.92 2 2
2 3 960.16 -1 15.31 0 0 0.00 / 792.92 2 2
3 12 2004.12 44 9.60 3086 1304 1.47 / 794.22 2 2
4 7 2001.60 24 11.35 3231 880 2.35 / 795.10 2 2
5 13 1606.04 36 12.58 2713 1229 3.58 / 796.33 2 2
6 13 592.60 36 13.52 1256 611 4.19 / 796.94 2 2
7 13 74.84 36 14.29 427 220 4.41 / 797.16 2 2
8 8 -0.08 170 14.38 302 738 5.15 / 797.90 2 5
Average= 5.39
(KJ/cycle)

Cycle 146 GMT 3/10/2020 5:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 26 14.40 463 173 0.17 / 787.40 2 2
2 12 2003.84 44 9.60 3082 1302 1.48 / 788.70 2 2
3 7 2001.32 24 11.36 3235 882 2.36 / 789.59 2 2
4 13 1737.76 36 12.45 2896 1298 3.66 / 790.88 2 2
5 13 813.32 36 13.30 1585 759 4.41 / 791.64 2 2
6 13 81.28 36 14.28 434 223 4.64 / 791.87 2 2
7 8 0.16 170 14.38 306 748 5.39 / 792.61 2 6
8 14 0.16 30 14.42 308 133 5.52 / 792.75 2 6
Average= 5.39
(KJ/cycle)

Cycle 145 GMT 23/ 9/2020 5:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 25 14.41 467 168 0.17 / 781.83 2 2
2 12 2003.44 44 9.68 3088 1315 1.48 / 783.15 2 2
3 7 2001.08 24 11.35 3246 884 2.37 / 784.03 2 2
4 13 1867.80 36 12.33 3056 1356 3.72 / 785.39 2 2
5 13 927.88 36 13.20 1756 834 4.56 / 786.22 2 2
6 13 119.32 36 14.19 500 255 4.81 / 786.48 2 2
7 8 0.00 170 14.37 308 752 5.57 / 787.23 2 3
Average= 5.39
(KJ/cycle)

Cycle 144 GMT 13/ 9/2020 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 25 14.41 458 165 0.16 / 775.92 2 2
2 12 1999.96 44 9.65 3095 1314 1.48 / 777.24 2 2
3 7 1996.96 24 11.36 3248 886 2.36 / 778.12 2 2
4 13 1722.32 49 12.19 2860 1708 4.07 / 779.83 2 2
5 13 569.96 49 13.46 1229 811 4.88 / 780.64 2 3
6 13 40.40 49 14.32 372 261 5.14 / 780.90 2 2
7 8 -0.04 170 14.31 313 761 5.91 / 781.66 2 8
Average= 5.39
(KJ/cycle)

Cycle 143 GMT 3/ 9/2020 6:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 25 14.39 458 165 0.16 / 769.84 2 2
2 12 2001.92 44 9.70 3100 1323 1.49 / 771.16 2 2
3 7 1999.20 24 11.38 3224 881 2.37 / 772.04 2 2
4 13 1852.96 49 12.03 3025 1783 4.15 / 773.83 2 2
5 13 681.76 49 13.32 1395 910 5.06 / 774.74 2 2
6 13 32.76 49 14.33 365 256 5.32 / 774.99 2 2
7 8 -0.12 170 14.32 313 762 6.08 / 775.76 2 7
Average= 5.39
(KJ/cycle)

Cycle 142 GMT 24/ 8/2020 6:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 25 14.40 463 167 0.17 / 763.58 2 2
2 12 2001.88 44 9.80 3102 1338 1.50 / 764.92 2 2
3 7 1999.24 24 11.40 3243 887 2.39 / 765.81 2 2
4 13 1863.76 49 12.03 3058 1803 4.19 / 767.61 2 2
5 13 828.96 49 13.16 1602 1033 5.23 / 768.64 2 2
6 13 49.64 49 14.29 385 270 5.50 / 768.91 2 3
7 8 -0.04 170 14.32 313 762 6.26 / 769.68 2 5
Average= 5.38
(KJ/cycle)

Cycle 141 GMT 14/ 8/2020 7:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 26 14.40 463 173 0.17 / 757.51 2 2
2 3 972.92 -1 15.31 0 0 0.00 / 757.51 2 2
3 12 2002.36 36 9.70 3074 1073 1.25 / 758.58 2 2
4 7 2000.08 24 11.48 3252 896 2.14 / 759.48 2 2
5 13 1871.20 49 12.00 3068 1804 3.95 / 761.28 2 2
6 13 875.36 49 13.08 1688 1082 5.03 / 762.36 2 3
7 13 65.36 49 14.26 421 294 5.32 / 762.66 2 3
8 8 -0.12 170 14.32 313 762 6.08 / 763.42 2 6
Average= 5.38
(KJ/cycle)

Cycle 140 GMT 4/ 8/2020 8:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 26 14.40 472 177 0.18 / 751.58 2 2
2 12 2003.72 36 9.70 3068 1071 1.25 / 752.65 2 2
3 7 2001.52 24 11.49 3240 893 2.14 / 753.55 2 2
4 13 1865.80 49 12.00 3059 1799 3.94 / 755.34 2 2
5 13 731.60 49 13.25 1475 958 4.90 / 756.30 2 2
6 13 41.68 49 14.32 380 267 5.16 / 756.57 2 3
7 8 0.04 170 14.32 314 764 5.93 / 757.33 2 5
Average= 5.37
(KJ/cycle)

Cycle 139 GMT 25/ 7/2020 8:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 25 14.37 461 166 0.17 / 745.33 2 2
2 3 1028.24 1 12.87 1925 25 0.19 / 745.36 2 2
3 3 1023.56 1 12.72 1931 25 0.21 / 745.38 2 2
4 12 2004.48 36 9.96 3063 1098 1.31 / 746.48 2 2
5 7 2002.44 24 11.48 3242 893 2.21 / 747.37 2 2
6 13 1869.44 49 12.01 3054 1797 4.00 / 749.17 2 2
7 13 1024.40 49 12.96 1856 1179 5.18 / 750.35 2 2
8 13 60.64 49 14.27 407 285 5.47 / 750.63 2 2
9 8 -0.08 170 14.31 316 769 6.24 / 751.40 2 8
Average= 5.37
(KJ/cycle)

Cycle 138 GMT 15/ 7/2020 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 25 14.40 463 167 0.17 / 739.14 2 2
2 12 2001.16 36 9.98 3085 1108 1.28 / 740.25 2 2
3 7 1998.72 24 11.47 3254 896 2.17 / 741.14 2 2
4 13 1857.68 49 12.01 3055 1798 3.97 / 742.94 2 2
5 13 999.52 49 12.95 1857 1178 5.15 / 744.12 2 2
6 13 51.36 49 14.27 400 280 5.43 / 744.40 2 3
7 8 -0.08 170 14.30 316 768 6.19 / 745.17 2 3
Average= 5.36
(KJ/cycle)

Cycle 137 GMT 5/ 7/2020 10:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 25 14.41 456 164 0.16 / 733.31 2 2
2 12 2004.36 36 9.97 3074 1103 1.27 / 734.41 2 2
3 7 2002.24 24 11.48 3237 892 2.16 / 735.30 2 2
4 13 1872.76 49 12.00 3061 1800 3.96 / 737.10 2 2
5 13 613.68 49 13.39 1289 846 4.81 / 737.95 2 2
6 13 48.68 49 14.29 390 273 5.08 / 738.22 2 3
7 8 -0.12 170 14.31 310 754 5.83 / 738.97 2 8
Average= 5.35
(KJ/cycle)

Cycle 136 GMT 25/ 6/2020 10:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 25 14.40 452 163 0.16 / 727.21 2 2
2 12 2002.36 36 10.01 3099 1117 1.28 / 728.32 2 2
3 7 2000.20 24 11.47 3250 895 2.17 / 729.22 2 2
4 13 1873.60 49 12.00 3063 1801 3.98 / 731.02 2 2
5 13 885.08 49 13.09 1680 1078 5.05 / 732.10 2 2
6 13 60.64 49 14.26 410 286 5.34 / 732.38 2 2
7 8 -0.12 170 14.31 311 757 6.10 / 733.14 2 6
Average= 5.35
(KJ/cycle)

Cycle 135 GMT 15/ 6/2020 11:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 25 14.41 456 164 0.16 / 721.27 2 2
2 12 2002.92 36 10.11 3087 1124 1.29 / 722.40 2 2
3 7 2000.40 24 11.48 3236 892 2.18 / 723.29 2 2
4 13 1856.80 49 12.01 3040 1789 3.97 / 725.08 2 2
5 13 704.40 49 13.28 1418 923 4.89 / 726.00 2 2
6 13 62.28 49 14.25 411 287 5.18 / 726.29 2 3
7 8 -0.04 170 14.29 312 758 5.94 / 727.05 2 6
Average= 5.35
(KJ/cycle)

Cycle 134 GMT 5/ 6/2020 11:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 25 14.41 458 165 0.16 / 715.30 2 2
2 12 2002.68 36 10.07 3116 1130 1.29 / 716.43 2 2
3 7 2000.24 24 11.46 3240 891 2.19 / 717.32 2 2
4 13 1863.32 49 11.98 3057 1795 3.98 / 719.11 2 2
5 13 718.64 49 13.26 1447 940 4.92 / 720.05 2 2
6 13 64.36 49 14.22 421 293 5.21 / 720.35 2 3
7 8 -0.16 170 14.27 314 762 5.98 / 721.11 2 12
Average= 5.34
(KJ/cycle)

Cycle 133 GMT 26/ 5/2020 12:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 25 14.43 450 162 0.16 / 709.36 2 2
2 12 2002.40 36 10.17 3102 1136 1.30 / 710.50 2 2
3 7 1999.92 24 11.45 3231 888 2.19 / 711.38 2 2
4 13 1862.32 49 12.00 3056 1797 3.98 / 713.18 2 2
5 13 718.96 49 13.25 1444 938 4.92 / 714.12 2 3
6 13 32.24 49 14.30 363 254 5.17 / 714.37 2 3
7 8 0.00 170 14.28 313 760 5.93 / 715.13 2 8
Average= 5.34
(KJ/cycle)

Cycle 132 GMT 16/ 5/2020 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 26 14.41 447 167 0.17 / 703.45 2 2
2 3 951.04 -1 15.33 0 0 0.00 / 703.45 2 2
3 12 2002.12 36 10.25 3111 1148 1.32 / 704.60 2 2
4 7 1999.76 24 11.49 3228 890 2.21 / 705.49 2 2
5 13 1858.32 49 11.99 3050 1792 4.00 / 707.28 2 2
6 13 686.32 49 13.29 1396 909 4.91 / 708.19 2 2
7 13 33.84 49 14.31 358 251 5.16 / 708.44 2 3
8 8 -0.08 170 14.29 312 758 5.92 / 709.20 2 5
Average= 5.33
(KJ/cycle)

Cycle 131 GMT 6/ 5/2020 13: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 26 14.39 472 177 0.18 / 697.51 2 2
2 12 2000.92 36 10.24 3130 1154 1.33 / 698.66 2 2
3 7 1998.56 24 11.45 3256 895 2.23 / 699.56 2 2
4 13 1860.60 49 11.99 3034 1783 4.01 / 701.34 2 2
5 13 722.00 49 13.25 1444 938 4.95 / 702.28 2 3
6 13 37.48 49 14.30 363 254 5.20 / 702.53 2 3
7 8 -0.08 170 14.29 310 753 5.95 / 703.28 2 7
Average= 5.33
(KJ/cycle)

Cycle 130 GMT 26/ 4/2020 13:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 25 14.38 477 171 0.17 / 691.64 2 2
2 3 1029.28 1 12.63 1930 24 0.20 / 691.67 2 2
3 12 2002.68 36 10.33 3134 1165 1.36 / 692.83 2 2
4 7 2000.16 24 11.50 3241 895 2.26 / 693.73 2 2
5 13 1861.84 49 11.99 3054 1794 4.05 / 695.52 2 2
6 13 571.16 49 13.42 1221 803 4.85 / 696.32 2 3
7 13 38.32 49 14.29 364 255 5.11 / 696.58 2 3
8 8 0.00 170 14.28 310 753 5.86 / 697.33 2 6
Average= 5.32
(KJ/cycle)

Cycle 129 GMT 16/ 4/2020 13:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 26 14.41 456 171 0.17 / 685.68 2 2
2 3 951.36 -1 15.33 0 0 0.00 / 685.68 2 2
3 12 2001.80 36 10.31 3124 1160 1.33 / 686.84 2 2
4 7 1999.36 24 11.47 3243 893 2.22 / 687.73 2 2
5 13 1857.08 49 11.98 3053 1792 4.02 / 689.52 2 2
6 13 693.88 49 13.28 1408 916 4.93 / 690.44 2 2
7 13 52.20 49 14.25 392 274 5.21 / 690.71 2 3
8 8 0.04 170 14.27 312 757 5.96 / 691.47 2 6
Average= 5.32
(KJ/cycle)

Cycle 128 GMT 6/ 4/2020 14:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 26 14.38 463 173 0.17 / 679.86 2 2
2 12 2001.36 36 10.34 3125 1163 1.34 / 681.02 2 2
3 7 1998.76 24 11.47 3242 892 2.23 / 681.91 2 2
4 13 1855.60 49 12.00 3034 1784 4.01 / 683.70 2 2
5 13 555.12 49 13.44 1206 794 4.81 / 684.49 2 2
6 13 40.96 49 14.29 373 261 5.07 / 684.75 2 2
7 8 -0.12 170 14.28 311 755 5.82 / 685.51 2 5
Average= 5.31
(KJ/cycle)

Cycle 127 GMT 27/ 3/2020 15: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 26 14.42 470 176 0.18 / 673.86 2 2
2 12 2001.80 36 10.41 3142 1177 1.35 / 675.03 2 2
3 7 1999.08 24 11.45 3252 894 2.25 / 675.93 2 2
4 13 1853.68 49 11.99 3047 1790 4.04 / 677.72 2 2
5 13 694.60 49 13.27 1413 919 4.96 / 678.64 2 2
6 13 55.68 49 14.25 405 283 5.24 / 678.92 2 3
7 8 -0.16 170 14.27 316 767 6.01 / 679.69 2 7
Average= 5.31
(KJ/cycle)

Cycle 126 GMT 17/ 3/2020 15:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 26 14.40 457 171 0.17 / 667.88 2 2
2 12 2000.84 36 10.37 3150 1176 1.35 / 669.06 2 2
3 7 1998.20 24 11.45 3235 889 2.24 / 669.95 2 2
4 13 1850.16 49 11.98 3039 1784 4.02 / 671.73 2 2
5 13 702.20 49 13.25 1427 926 4.95 / 672.66 2 2
6 13 30.76 49 14.29 365 256 5.20 / 672.91 2 3
7 8 -0.08 170 14.26 316 766 5.97 / 673.68 2 5
Average= 5.30
(KJ/cycle)

Cycle 125 GMT 7/ 3/2020 16: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 26 14.42 458 172 0.17 / 661.77 2 2
2 12 2002.56 36 10.48 3131 1181 1.35 / 662.95 2 2
3 7 1999.96 24 11.42 3235 887 2.24 / 663.84 2 2
4 13 1855.92 49 11.99 3037 1784 4.02 / 665.62 2 2
5 13 850.76 49 13.09 1632 1047 5.07 / 666.67 2 2
6 13 49.72 49 14.25 398 278 5.35 / 666.95 2 3
7 8 -0.16 170 14.26 315 764 6.11 / 667.71 2 5
Average= 5.30
(KJ/cycle)

Cycle 124 GMT 26/ 2/2020 16:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 26 14.39 465 174 0.17 / 655.99 2 2
2 12 2000.52 36 10.39 3153 1179 1.35 / 657.17 2 2
3 7 1997.88 24 11.46 3244 892 2.25 / 658.06 2 2
4 13 1717.68 49 12.15 2851 1697 3.94 / 659.76 2 2
5 13 583.48 49 13.39 1248 819 4.76 / 660.58 2 3
6 13 43.52 49 14.28 381 267 5.03 / 660.84 2 2
7 8 -0.16 170 14.28 311 755 5.78 / 661.60 2 3
Average= 5.29
(KJ/cycle)

Cycle 123 GMT 16/ 2/2020 16:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 26 14.37 453 169 0.17 / 650.00 2 2
2 12 2000.76 36 10.48 3149 1188 1.36 / 651.19 2 2
3 7 1998.08 24 11.44 3237 889 2.25 / 652.08 2 2
4 13 1858.92 49 11.97 3034 1780 4.03 / 653.86 2 2
5 13 698.44 49 13.26 1416 920 4.95 / 654.78 2 2
6 13 60.72 49 14.24 410 286 5.23 / 655.06 2 2
7 8 0.04 170 14.27 311 754 5.99 / 655.82 2 5
Average= 5.29
(KJ/cycle)

Cycle 122 GMT 6/ 2/2020 17:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 26 14.41 453 170 0.17 / 643.97 2 2
2 12 2003.76 36 10.57 3145 1197 1.37 / 645.17 2 2
3 7 2001.16 24 11.44 3256 894 2.26 / 646.06 2 2
4 13 1860.96 49 11.96 3054 1790 4.05 / 647.85 2 2
5 13 714.36 49 13.24 1436 932 4.98 / 648.79 2 3
6 13 63.60 49 14.23 416 290 5.27 / 649.08 2 3
7 8 -0.08 170 14.27 311 754 6.03 / 649.83 2 14
Average= 5.28
(KJ/cycle)

Cycle 121 GMT 27/ 1/2020 17:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 26 14.40 465 174 0.17 / 637.95 2 2
2 12 2001.76 36 10.63 3140 1202 1.38 / 639.15 2 2
3 7 1999.12 24 11.43 3256 893 2.27 / 640.04 2 2
4 13 1859.84 49 11.96 3051 1788 4.06 / 641.83 2 2
5 13 705.16 49 13.24 1424 924 4.98 / 642.75 2 3
6 13 61.88 49 14.23 417 291 5.27 / 643.04 2 3
7 8 -0.16 170 14.25 314 761 6.03 / 643.80 2 7
Average= 5.28
(KJ/cycle)

Cycle 120 GMT 17/ 1/2020 18:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 26 14.41 466 175 0.17 / 631.94 2 2
2 12 2003.52 36 10.56 3133 1191 1.37 / 633.13 2 2
3 7 2000.88 24 11.42 3244 889 2.25 / 634.02 2 2
4 13 1866.44 49 11.96 3051 1788 4.04 / 635.81 2 2
5 13 693.20 49 13.25 1415 919 4.96 / 636.72 2 2
6 13 61.20 49 14.24 413 288 5.25 / 637.01 2 2
7 8 -0.12 170 14.26 313 759 6.01 / 637.77 2 6
Average= 5.27
(KJ/cycle)

Cycle 119 GMT 7/ 1/2020 18:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 26 14.40 470 176 0.18 / 625.93 2 2
2 12 2001.56 36 10.65 3142 1205 1.38 / 627.13 2 2
3 7 1999.16 24 11.44 3234 888 2.27 / 628.02 2 2
4 13 1854.36 49 11.99 3036 1784 4.05 / 629.81 2 2
5 13 692.64 49 13.25 1414 918 4.97 / 630.72 2 2
6 13 59.36 49 14.25 408 285 5.26 / 631.01 2 2
7 8 -0.04 170 14.27 311 754 6.01 / 631.76 2 7
Average= 5.26
(KJ/cycle)

Cycle 118 GMT 28/12/2019 19:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 26 14.43 457 171 0.17 / 619.98 2 2
2 12 2001.32 36 10.65 3146 1206 1.38 / 621.19 2 2
3 7 1998.80 24 11.46 3234 889 2.27 / 622.08 2 2
4 13 1709.76 49 12.14 2849 1695 3.96 / 623.77 2 2
5 13 711.20 49 13.23 1440 934 4.90 / 624.70 2 2
6 13 63.28 49 14.24 416 290 5.19 / 624.99 2 2
7 8 -0.20 170 14.27 313 759 5.94 / 625.75 2 3
Average= 5.26
(KJ/cycle)

Cycle 117 GMT 18/12/2019 19:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 27 14.40 473 184 0.18 / 613.99 2 2
2 12 2006.60 36 10.56 3151 1198 1.38 / 615.18 2 2
3 7 2004.36 24 11.41 3244 888 2.27 / 616.07 2 2
4 13 1866.48 49 11.96 3067 1797 4.07 / 617.87 2 2
5 13 701.92 49 13.25 1431 929 5.00 / 618.80 2 2
6 13 33.00 49 14.33 362 254 5.25 / 619.05 2 2
7 8 -0.12 170 14.29 311 756 6.01 / 619.81 2 4
Average= 5.25
(KJ/cycle)

Cycle 116 GMT 8/12/2019 20:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 25 14.39 462 166 0.17 / 608.00 2 2
2 3 1042.04 1 12.48 1933 24 0.19 / 608.03 2 2
3 3 1020.60 1 12.25 1929 24 0.21 / 608.05 2 2
4 12 2001.92 36 10.70 3138 1209 1.42 / 609.26 2 2
5 7 1999.16 24 11.50 3232 892 2.31 / 610.15 2 2
6 13 1714.96 49 12.15 2849 1696 4.01 / 611.85 2 2
7 13 724.64 49 13.22 1457 944 4.95 / 612.79 2 2
8 13 32.72 49 14.32 363 255 5.21 / 613.05 2 2
9 8 -0.04 170 14.28 311 755 5.96 / 613.80 2 3
Average= 5.25
(KJ/cycle)

Cycle 115 GMT 28/11/2019 20:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 26 14.41 456 171 0.17 / 602.06 2 2
2 12 2002.04 36 10.58 3168 1207 1.38 / 603.26 2 2
3 7 1999.28 24 11.46 3257 896 2.27 / 604.16 2 2
4 13 1716.16 49 12.14 2850 1695 3.97 / 605.86 2 2
5 13 712.36 49 13.24 1443 936 4.90 / 606.79 2 2
6 13 61.20 49 14.25 407 284 5.19 / 607.08 2 2
7 8 -0.16 170 14.27 314 762 5.95 / 607.84 2 4
Average= 5.24
(KJ/cycle)

Cycle 114 GMT 18/11/2019 20:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 25 14.40 470 169 0.17 / 596.06 2 2
2 12 2004.32 36 10.80 3144 1222 1.39 / 597.28 2 2
3 7 2001.60 24 11.45 3233 888 2.28 / 598.17 2 2
4 13 1857.24 49 11.97 3032 1778 4.06 / 599.95 2 2
5 13 676.08 49 13.28 1378 897 4.96 / 600.85 2 2
6 13 55.28 49 14.26 400 279 5.23 / 601.13 2 2
7 8 0.00 170 14.26 314 761 6.00 / 601.89 2 6
Average= 5.23
(KJ/cycle)

Cycle 113 GMT 8/11/2019 21:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 26 14.38 466 174 0.17 / 590.19 2 2
2 12 2003.08 36 10.69 3145 1210 1.38 / 591.40 2 2
3 7 2000.40 24 11.45 3214 883 2.27 / 592.28 2 2
4 13 1856.56 49 11.96 3036 1779 4.05 / 594.06 2 2
5 13 571.60 49 13.40 1229 807 4.85 / 594.87 2 2
6 13 43.40 49 14.28 379 265 5.12 / 595.13 2 2
7 8 -0.04 170 14.25 313 758 5.88 / 595.89 2 4
Average= 5.23
(KJ/cycle)

Cycle 112 GMT 29/10/2019 21:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 26 14.41 464 174 0.17 / 584.25 2 2
2 12 2000.32 36 10.79 3136 1218 1.39 / 585.47 2 2
3 7 1997.36 24 11.43 3218 883 2.27 / 586.36 2 2
4 13 1717.64 49 12.12 2851 1693 3.97 / 588.05 2 2
5 13 719.28 49 13.23 1436 931 4.90 / 588.98 2 2
6 13 63.12 49 14.23 406 283 5.18 / 589.26 2 2
7 8 -0.16 170 14.25 310 751 5.93 / 590.01 2 7
Average= 5.22
(KJ/cycle)

Cycle 111 GMT 19/10/2019 21:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 25 14.40 462 166 0.17 / 578.39 2 2
2 3 1019.76 1 10.88 1939 21 0.19 / 578.41 2 2
3 12 2002.00 36 10.76 3135 1214 1.40 / 579.63 2 2
4 7 1999.44 24 11.48 3241 893 2.29 / 580.52 2 2
5 13 1853.52 49 12.00 3035 1785 4.08 / 582.30 2 2
6 13 548.08 49 13.43 1188 782 4.86 / 583.09 2 3
7 13 38.08 49 14.31 354 248 5.11 / 583.33 2 3
8 8 -0.20 170 14.26 308 747 5.86 / 584.08 2 5
Average= 5.22
(KJ/cycle)

Cycle 110 GMT 9/10/2019 22:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 25 14.39 459 165 0.17 / 572.75 2 2
2 12 2001.64 36 10.81 3140 1222 1.39 / 573.97 2 2
3 7 1998.84 24 11.46 3238 891 2.28 / 574.87 2 2
4 13 1711.20 49 12.14 2845 1692 3.97 / 576.56 2 2
5 13 702.20 49 13.25 1419 921 4.89 / 577.48 2 3
6 8 0.20 170 14.29 307 746 5.64 / 578.22 2 4
Average= 5.21
(KJ/cycle)

Cycle 109 GMT 29/ 9/2019 23: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 25 14.41 463 167 0.17 / 567.00 2 2
2 12 2001.48 36 10.84 3139 1225 1.39 / 568.22 2 2
3 7 1998.60 24 11.48 3213 885 2.28 / 569.11 2 2
4 13 1710.72 49 12.14 2852 1697 3.97 / 570.80 2 2
5 13 575.40 49 13.40 1232 809 4.78 / 571.61 2 2
6 13 20.04 49 14.35 329 231 5.01 / 571.84 2 2
7 8 -0.20 170 14.23 308 745 5.76 / 572.59 2 4
Average= 5.21
(KJ/cycle)

Cycle 108 GMT 19/ 9/2019 23:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 25 14.45 453 164 0.16 / 560.91 2 2
2 12 2004.28 36 10.75 3148 1218 1.38 / 562.13 2 2
3 7 2001.80 24 11.42 3240 888 2.27 / 563.02 2 2
4 13 1860.60 49 11.95 3059 1791 4.06 / 564.81 2 2
5 13 827.40 49 13.10 1601 1028 5.09 / 565.84 2 3
6 13 26.20 49 14.33 350 246 5.33 / 566.08 2 2
7 8 0.00 170 14.26 308 747 6.08 / 566.83 2 3
Average= 5.20
(KJ/cycle)

Cycle 107 GMT 9/ 9/2019 23:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 26 14.42 457 171 0.17 / 555.13 2 2
2 3 973.64 -1 15.36 0 0 0.00 / 555.13 2 2
3 12 2000.88 36 10.80 3148 1224 1.40 / 556.35 2 2
4 7 1998.24 24 11.44 3227 886 2.28 / 557.24 2 2
5 13 1714.44 49 12.13 2848 1693 3.97 / 558.93 2 2
6 13 569.60 49 13.40 1223 803 4.78 / 559.73 2 2
7 13 37.56 49 14.29 370 259 5.04 / 559.99 2 2
8 8 -0.12 170 14.24 312 755 5.79 / 560.75 2 6
Average= 5.19
(KJ/cycle)

Cycle 106 GMT 31/ 8/2019 0: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 25 14.40 463 167 0.17 / 549.27 2 2
2 12 2000.96 36 10.85 3148 1230 1.40 / 550.50 2 2
3 7 1998.40 24 11.50 3242 895 2.29 / 551.39 2 2
4 13 1851.40 49 11.97 3036 1781 4.07 / 553.17 2 2
5 13 546.00 49 13.43 1184 779 4.85 / 553.95 2 2
6 13 37.08 49 14.31 356 250 5.10 / 554.20 2 2
7 8 -0.08 170 14.25 311 753 5.85 / 554.96 2 5
Average= 5.19
(KJ/cycle)

Cycle 105 GMT 21/ 8/2019 0:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 25 14.39 471 169 0.17 / 543.25 2 2
2 12 2003.28 36 10.87 3159 1236 1.41 / 544.49 2 2
3 7 2000.84 24 11.45 3255 894 2.30 / 545.38 2 2
4 13 1855.20 49 11.94 3047 1783 4.08 / 547.17 2 2
5 13 675.48 49 13.26 1383 899 4.98 / 548.07 2 2
6 13 52.04 49 14.26 395 276 5.26 / 548.34 2 2
7 8 -0.12 170 14.24 314 760 6.02 / 549.10 2 10
Average= 5.18
(KJ/cycle)

Cycle 104 GMT 11/ 8/2019 1:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 25 14.40 464 167 0.17 / 537.24 2 2
2 12 2004.04 36 10.78 3145 1221 1.39 / 538.46 2 2
3 7 2001.44 24 11.45 3258 895 2.28 / 539.36 2 2
4 13 1858.12 49 11.96 3040 1782 4.06 / 541.14 2 2
5 13 679.56 49 13.25 1396 906 4.97 / 542.04 2 3
6 13 55.68 49 14.24 402 280 5.25 / 542.33 2 3
7 8 -0.20 170 14.23 314 760 6.01 / 543.08 2 4
Average= 5.17
(KJ/cycle)

Cycle 103 GMT 1/ 8/2019 1:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 25 14.43 464 167 0.17 / 531.58 2 2
2 12 2000.48 36 10.94 3142 1237 1.40 / 532.82 2 2
3 7 1997.84 24 11.50 3251 897 2.30 / 533.72 2 2
4 13 1711.48 49 12.12 2855 1696 4.00 / 535.41 2 2
5 13 691.76 49 13.24 1409 914 4.91 / 536.32 2 2
6 8 -0.08 170 14.26 309 749 5.66 / 537.07 2 3
Average= 5.16
(KJ/cycle)

Cycle 102 GMT 22/ 7/2019 2:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 25 14.39 476 171 0.17 / 525.83 2 2
2 12 2004.08 36 10.88 3146 1232 1.40 / 527.06 2 2
3 7 2001.48 24 11.49 3244 895 2.30 / 527.95 2 2
4 13 1865.16 49 11.93 3063 1791 4.09 / 529.75 2 2
5 13 679.44 49 13.25 1396 906 4.99 / 530.65 2 2
6 8 0.00 170 14.26 314 761 5.76 / 531.41 2 3
Average= 5.16
(KJ/cycle)

Cycle 101 GMT 12/ 7/2019 2:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 25 14.40 470 169 0.17 / 520.01 2 2
2 12 2001.88 36 10.93 3154 1241 1.41 / 521.25 2 2
3 7 1998.88 24 11.51 3225 891 2.30 / 522.14 2 2
4 13 1700.36 49 12.14 2838 1688 3.99 / 523.83 2 2
5 13 574.04 49 13.39 1235 810 4.80 / 524.64 2 2
6 13 36.48 49 14.28 372 260 5.06 / 524.90 2 2
7 8 -0.08 170 14.21 314 759 5.82 / 525.66 2 5
Average= 5.15
(KJ/cycle)

Cycle 100 GMT 2/ 7/2019 3: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 25 14.40 465 167 0.17 / 513.99 2 2
2 12 2001.68 36 10.98 3137 1240 1.41 / 515.23 2 2
3 7 1999.04 24 11.54 3239 897 2.30 / 516.13 2 2
4 13 1852.84 49 11.96 3044 1784 4.09 / 517.92 2 2
5 13 655.36 49 13.29 1358 884 4.97 / 518.80 2 3
6 13 50.96 49 14.25 394 275 5.25 / 519.07 2 2
7 8 -0.12 170 14.22 316 764 6.01 / 519.84 2 5
Average= 5.15
(KJ/cycle)

Cycle 99 GMT 22/ 6/2019 3:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 25 14.42 465 168 0.17 / 508.21 2 2
2 12 1999.96 36 10.92 3145 1236 1.40 / 509.45 2 2
3 7 1997.20 24 11.49 3224 889 2.29 / 510.34 2 2
4 13 1704.04 49 12.14 2845 1692 3.99 / 512.03 2 2
5 13 544.44 49 13.42 1195 786 4.77 / 512.82 2 2
6 13 32.08 49 14.29 365 256 5.03 / 513.07 2 3
7 8 -0.20 170 14.22 312 754 5.78 / 513.83 2 5
Average= 5.14
(KJ/cycle)

Cycle 98 GMT 12/ 6/2019 4:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 25 14.40 472 170 0.17 / 502.39 2 2
2 12 2001.20 36 10.97 3163 1249 1.42 / 503.64 2 2
3 7 1998.32 24 11.53 3246 898 2.32 / 504.54 2 2
4 13 1712.40 49 12.14 2850 1695 4.01 / 506.23 2 2
5 13 554.52 49 13.41 1212 796 4.81 / 507.03 2 2
6 13 37.04 49 14.28 372 260 5.07 / 507.29 2 3
7 8 -0.08 170 14.22 312 754 5.82 / 508.05 2 6
Average= 5.13
(KJ/cycle)

Cycle 97 GMT 2/ 6/2019 4:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 24 14.44 453 157 0.16 / 496.35 2 2
2 3 1024.96 1 11.65 1922 22 0.18 / 496.37 2 2
3 12 1999.92 36 11.01 3137 1243 1.42 / 497.61 2 2
4 7 1997.28 25 11.54 3215 928 2.35 / 498.54 2 2
5 13 1852.96 49 11.99 3027 1778 4.13 / 500.32 2 2
6 13 660.76 49 13.29 1359 885 5.01 / 501.20 2 2
7 13 47.36 49 14.27 378 264 5.28 / 501.47 2 3
8 8 -0.08 170 14.22 312 754 6.03 / 502.22 2 4
Average= 5.12
(KJ/cycle)

Cycle 96 GMT 23/ 5/2019 4:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 25 14.43 457 165 0.16 / 490.78 2 2
2 12 2003.72 36 11.03 3153 1252 1.42 / 492.04 2 2
3 7 2001.04 24 11.55 3261 904 2.32 / 492.94 2 2
4 13 1713.40 49 12.15 2848 1696 4.02 / 494.64 2 2
5 13 562.92 49 13.40 1216 798 4.81 / 495.43 2 3
6 8 0.04 170 14.25 312 756 5.57 / 496.19 2 6
Average= 5.12
(KJ/cycle)

Cycle 95 GMT 13/ 5/2019 5: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 24 14.45 459 159 0.16 / 484.76 2 2
2 12 1999.88 36 11.18 3141 1264 1.42 / 486.02 2 2
3 7 1996.84 24 11.61 3257 908 2.33 / 486.93 2 2
4 13 1849.32 49 12.00 3040 1788 4.12 / 488.72 2 2
5 13 654.40 49 13.28 1354 881 5.00 / 489.60 2 2
6 13 46.64 49 14.27 379 265 5.26 / 489.86 2 2
7 8 -0.12 170 14.21 313 756 6.02 / 490.62 2 10
Average= 5.11
(KJ/cycle)

Cycle 94 GMT 3/ 5/2019 5:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 25 14.42 458 165 0.17 / 478.90 2 2
2 12 2001.44 36 11.06 3148 1253 1.42 / 480.15 2 2
3 7 1998.72 24 11.58 3248 903 2.32 / 481.05 2 2
4 13 1854.92 49 11.97 3044 1785 4.11 / 482.84 2 2
5 13 529.04 49 13.44 1166 768 4.87 / 483.61 2 3
6 13 16.08 49 14.35 331 233 5.11 / 483.84 2 2
7 8 -0.12 170 14.19 315 760 5.87 / 484.60 2 6
Average= 5.10
(KJ/cycle)

Cycle 93 GMT 23/ 4/2019 5:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 25 14.42 466 168 0.17 / 472.84 2 2
2 12 2000.28 36 10.95 3152 1243 1.41 / 474.09 2 2
3 7 1997.60 24 11.58 3253 904 2.31 / 474.99 2 2
4 13 1856.60 49 11.99 3049 1791 4.11 / 476.78 2 2
5 13 677.72 49 13.27 1395 907 5.01 / 477.69 2 2
6 13 53.64 49 14.26 401 280 5.29 / 477.97 2 3
7 8 -0.16 170 14.22 315 761 6.05 / 478.73 2 3
Average= 5.09
(KJ/cycle)

Cycle 92 GMT 13/ 4/2019 6: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 25 14.47 460 166 0.17 / 467.09 2 2
2 12 2002.16 36 11.00 3137 1242 1.41 / 468.33 2 2
3 7 1999.64 24 11.58 3250 903 2.31 / 469.24 2 2
4 13 1575.28 49 12.31 2659 1604 3.92 / 470.84 2 2
5 13 570.56 49 13.41 1239 814 4.73 / 471.65 2 3
6 13 35.76 49 14.30 374 262 4.99 / 471.92 2 3
7 8 -0.08 170 14.22 315 761 5.75 / 472.68 2 6
Average= 5.08
(KJ/cycle)

Cycle 91 GMT 3/ 4/2019 6:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 26 14.42 455 171 0.17 / 461.12 2 2
2 3 922.40 -1 15.40 0 0 0.00 / 461.12 2 2
3 3 971.56 -1 15.39 0 0 0.00 / 461.12 2 2
4 12 2002.20 36 11.06 3139 1250 1.42 / 462.37 2 2
5 7 1999.40 24 11.62 3237 903 2.32 / 463.27 2 2
6 13 1713.80 49 12.18 2839 1694 4.02 / 464.97 2 2
7 13 711.36 49 13.24 1439 934 4.95 / 465.90 2 2
8 13 29.24 49 14.31 365 256 5.21 / 466.16 2 3
9 8 -0.12 170 14.21 317 766 5.97 / 466.92 2 5
Average= 5.08
(KJ/cycle)

Cycle 90 GMT 24/ 3/2019 7:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 25 14.43 480 173 0.17 / 455.45 2 2
2 3 1044.12 1 12.53 1940 24 0.20 / 455.48 2 2
3 3 1029.08 1 12.67 1925 24 0.22 / 455.50 2 2
4 12 2005.56 36 11.10 3153 1260 1.48 / 456.76 2 2
5 7 2003.00 24 11.70 3234 908 2.39 / 457.67 2 2
6 13 1578.36 49 12.32 2656 1603 3.99 / 459.27 2 2
7 13 446.60 49 13.58 1041 693 4.69 / 459.97 2 3
8 13 23.64 49 14.33 344 242 4.93 / 460.21 2 3
9 8 -0.16 170 14.23 307 743 5.67 / 460.95 2 4
Average= 5.07
(KJ/cycle)

Cycle 89 GMT 14/ 3/2019 7:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 25 14.43 470 170 0.17 / 449.40 2 2
2 12 2000.92 36 11.15 3135 1258 1.43 / 450.66 2 2
3 7 1998.20 24 11.63 3241 905 2.33 / 451.57 2 2
4 13 1851.96 49 12.03 3039 1791 4.12 / 453.36 2 2
5 13 670.84 49 13.29 1378 897 5.02 / 454.25 2 2
6 13 27.76 49 14.31 364 255 5.28 / 454.51 2 2
7 8 -0.16 170 14.21 319 771 6.05 / 455.28 2 4
Average= 5.06
(KJ/cycle)

Cycle 88 GMT 4/ 3/2019 8: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 25 14.43 464 167 0.17 / 443.31 2 2
2 12 2001.24 36 11.23 3129 1265 1.43 / 444.58 2 2
3 7 1998.80 24 11.68 3242 909 2.34 / 445.49 2 2
4 13 1852.40 49 12.04 3046 1797 4.14 / 447.28 2 2
5 13 668.28 49 13.30 1378 898 5.04 / 448.18 2 2
6 13 48.76 49 14.26 395 276 5.31 / 448.46 2 3
7 8 -0.16 170 14.19 321 774 6.09 / 449.23 2 8
Average= 5.05
(KJ/cycle)

Cycle 87 GMT 22/ 2/2019 8:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 24 14.47 455 158 0.16 / 437.42 2 2
2 12 2003.24 36 11.16 3148 1265 1.42 / 438.68 2 2
3 7 2000.72 24 11.71 3241 911 2.33 / 439.59 2 2
4 13 1854.92 49 12.05 3039 1794 4.13 / 441.39 2 2
5 13 541.72 49 13.46 1184 781 4.91 / 442.17 2 3
6 13 14.56 49 14.36 329 231 5.14 / 442.40 2 3
7 8 -0.08 170 14.19 310 748 5.89 / 443.15 2 9
Average= 5.04
(KJ/cycle)

Cycle 86 GMT 12/ 2/2019 9:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 25 14.45 461 167 0.17 / 431.64 2 2
2 12 2003.12 36 11.11 3117 1247 1.41 / 432.89 2 2
3 7 2000.32 24 11.66 3260 912 2.33 / 433.80 2 2
4 13 1855.68 49 12.05 3044 1797 4.12 / 435.60 2 2
5 13 667.20 49 13.30 1379 899 5.02 / 436.50 2 2
6 8 0.16 170 14.27 314 762 5.78 / 437.26 2 4
Average= 5.03
(KJ/cycle)

Cycle 85 GMT 2/ 2/2019 9:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 25 14.45 465 168 0.17 / 425.81 2 2
2 12 1999.92 36 11.08 3123 1246 1.41 / 427.05 2 2
3 7 1996.92 24 11.66 3234 905 2.32 / 427.96 2 2
4 13 1708.48 49 12.22 2833 1696 4.02 / 429.65 2 2
5 13 558.20 49 13.45 1214 800 4.82 / 430.45 2 2
6 13 33.12 49 14.31 368 258 5.07 / 430.71 2 3
7 8 -0.16 170 14.20 316 763 5.84 / 431.48 2 6
Average= 5.02
(KJ/cycle)

Cycle 84 GMT 23/ 1/2019 9:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 24 14.45 469 163 0.16 / 419.82 2 2
2 12 2003.36 36 11.18 3129 1259 1.42 / 421.08 2 2
3 7 2000.60 24 11.72 3240 911 2.33 / 421.99 2 2
4 13 1716.64 49 12.21 2858 1710 4.04 / 423.70 2 2
5 13 697.84 49 13.29 1414 921 4.96 / 424.62 2 3
6 13 26.52 49 14.33 360 253 5.22 / 424.87 2 2
7 8 -0.08 170 14.21 317 766 5.98 / 425.64 2 9
Average= 5.01
(KJ/cycle)

Cycle 83 GMT 13/ 1/2019 9:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 24 14.48 454 158 0.16 / 414.00 2 2
2 12 2001.56 36 11.08 3133 1250 1.41 / 415.25 2 2
3 7 1999.00 24 11.73 3219 906 2.31 / 416.16 2 2
4 13 1705.00 49 12.24 2842 1705 4.02 / 417.87 2 2
5 13 549.72 49 13.46 1202 793 4.81 / 418.66 2 3
6 13 15.28 49 14.36 340 239 5.05 / 418.90 2 2
7 8 -0.12 170 14.18 315 759 5.81 / 419.66 2 4
Average= 5.00
(KJ/cycle)

Cycle 82 GMT 3/ 1/2019 10:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 25 14.43 464 167 0.17 / 408.15 2 2
2 3 971.32 -1 15.42 0 0 0.00 / 408.15 2 2
3 12 2000.48 36 11.12 3161 1265 1.43 / 409.42 2 2
4 7 1997.56 24 11.74 3238 912 2.35 / 410.33 2 2
5 13 1709.88 49 12.25 2824 1695 4.04 / 412.03 2 2
6 13 555.00 49 13.46 1207 796 4.84 / 412.82 2 3
7 13 32.20 49 14.32 368 258 5.09 / 413.08 2 3
8 8 -0.08 170 14.20 317 765 5.86 / 413.85 2 9
Average= 4.99
(KJ/cycle)

Cycle 81 GMT 24/12/2018 10:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 25 14.46 468 169 0.17 / 402.07 2 2
2 12 2003.24 36 11.12 3135 1255 1.42 / 403.33 2 2
3 7 2000.68 25 11.71 3247 951 2.37 / 404.28 2 2
4 13 1861.16 49 12.07 3044 1800 4.18 / 406.08 2 2
5 13 662.28 49 13.33 1372 896 5.07 / 406.98 2 3
6 13 23.56 49 14.35 352 248 5.32 / 407.22 2 3
7 8 -0.12 170 14.21 316 763 6.08 / 407.99 2 7
Average= 4.98
(KJ/cycle)

Cycle 80 GMT 14/12/2018 10:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 24 14.46 470 163 0.16 / 396.29 2 2
2 12 2006.40 36 11.15 3149 1264 1.43 / 397.55 2 2
3 7 2003.72 24 11.77 3264 922 2.35 / 398.48 2 2
4 13 1862.40 49 12.09 3056 1810 4.16 / 400.29 2 2
5 13 647.72 49 13.36 1338 876 5.04 / 401.16 2 3
6 8 -0.08 170 14.29 306 743 5.78 / 401.91 2 4
Average= 4.96
(KJ/cycle)

Cycle 79 GMT 4/12/2018 10:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 24 14.46 467 162 0.16 / 390.61 2 2
2 12 2001.72 36 11.09 3155 1260 1.42 / 391.87 2 2
3 7 1999.16 24 11.73 3263 919 2.34 / 392.79 2 2
4 13 1853.12 49 12.10 3041 1803 4.14 / 394.59 2 2
5 13 523.56 49 13.50 1166 771 4.91 / 395.36 2 3
6 8 -0.04 170 14.27 315 764 5.68 / 396.13 2 4
Average= 4.95
(KJ/cycle)

Cycle 78 GMT 24/11/2018 11: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 25 14.47 468 169 0.17 / 384.55 2 2
2 12 2003.80 36 11.05 3154 1255 1.42 / 385.80 2 2
3 7 2001.36 24 11.73 3256 917 2.34 / 386.72 2 2
4 13 1858.60 49 12.09 3051 1807 4.15 / 388.53 2 2
5 13 641.84 49 13.37 1340 878 5.03 / 389.40 2 3
6 13 46.84 49 14.31 390 273 5.30 / 389.68 2 3
7 8 -0.08 170 14.21 319 771 6.07 / 390.45 2 6
Average= 4.94
(KJ/cycle)

Cycle 77 GMT 14/11/2018 11:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 24 14.46 470 163 0.16 / 378.47 2 2
2 12 2005.20 36 10.95 3158 1245 1.41 / 379.72 2 2
3 7 2003.04 24 11.72 3251 914 2.32 / 380.63 2 2
4 13 1861.60 49 12.10 3055 1811 4.13 / 382.44 2 2
5 13 683.08 49 13.33 1401 915 5.05 / 383.36 2 2
6 13 27.68 49 14.35 362 255 5.30 / 383.61 2 2
7 8 -0.20 170 14.21 317 766 6.07 / 384.38 2 5
Average= 4.93
(KJ/cycle)

Cycle 76 GMT 4/11/2018 12:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 25 14.46 471 170 0.17 / 372.43 2 2
2 12 2002.88 36 11.01 3125 1239 1.41 / 373.67 2 2
3 7 2000.24 24 11.73 3244 913 2.32 / 374.58 2 2
4 13 1855.08 49 12.11 3058 1815 4.14 / 376.39 2 2
5 13 668.32 49 13.35 1385 906 5.04 / 377.30 2 2
6 13 23.24 49 14.37 351 247 5.29 / 377.55 2 2
7 8 0.00 170 14.23 315 762 6.05 / 378.31 2 2
Average= 4.91
(KJ/cycle)

Cycle 75 GMT 25/10/2018 12:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 25 14.50 462 167 0.17 / 366.34 2 2
2 12 2001.72 36 10.84 3158 1232 1.40 / 367.58 2 2
3 7 1999.20 24 11.71 3265 918 2.32 / 368.49 2 2
4 13 1852.24 49 12.12 3044 1808 4.13 / 370.30 2 2
5 13 675.24 49 13.36 1397 915 5.04 / 371.22 2 2
6 13 50.32 49 14.31 398 279 5.32 / 371.50 2 3
7 8 -0.12 170 14.22 315 761 6.08 / 372.26 2 2
Average= 4.90
(KJ/cycle)

Cycle 74 GMT 15/10/2018 12:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 25 14.50 478 173 0.17 / 360.84 2 2
2 12 2002.04 36 10.96 3162 1248 1.42 / 362.08 2 2
3 7 1999.32 24 11.74 3240 913 2.33 / 363.00 2 2
4 13 1727.04 49 12.31 2886 1741 4.07 / 364.74 2 2
5 13 427.16 49 13.69 1011 678 4.75 / 365.42 2 3
6 8 0.00 170 14.28 313 760 5.51 / 366.18 2 5
Average= 4.88
(KJ/cycle)

Cycle 73 GMT 5/10/2018 13: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 24 14.49 471 164 0.16 / 355.58 2 2
2 12 2003.16 36 11.04 3146 1250 1.41 / 356.83 2 2
3 7 2000.48 24 11.78 3211 908 2.32 / 357.73 2 2
4 13 1570.80 49 12.46 2633 1608 3.93 / 359.34 2 2
5 13 312.48 49 13.88 822 559 4.49 / 359.90 2 3
6 8 0.00 170 14.28 314 762 5.25 / 360.66 2 4
Average= 4.87
(KJ/cycle)

Cycle 72 GMT 25/ 9/2018 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 25 14.51 475 172 0.17 / 349.88 2 2
2 12 2005.92 36 11.00 3133 1241 1.41 / 351.12 2 2
3 7 2003.44 24 11.74 3226 909 2.32 / 352.03 2 2
4 13 1870.20 49 12.12 3081 1830 4.15 / 353.86 2 2
5 13 554.12 49 13.53 1209 802 4.95 / 354.66 2 3
6 8 0.08 170 14.30 310 754 5.71 / 355.41 2 3
Average= 4.87
(KJ/cycle)

Cycle 71 GMT 15/ 9/2018 13:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 25 14.50 471 171 0.17 / 344.39 2 2
2 12 1999.88 36 10.98 3147 1244 1.41 / 345.64 2 2
3 7 1996.84 24 11.73 3235 911 2.33 / 346.55 2 2
4 13 1707.56 49 12.34 2848 1722 4.05 / 348.27 2 2
5 13 420.36 49 13.71 1004 674 4.72 / 348.94 2 3
6 8 -0.04 170 14.29 314 763 5.48 / 349.71 2 6
Average= 4.86
(KJ/cycle)

Cycle 70 GMT 5/ 9/2018 13:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 26 14.50 474 179 0.18 / 338.90 2 2
2 3 956.04 -1 15.43 0 0 0.00 / 338.90 2 2
3 12 2001.36 36 10.96 3150 1243 1.42 / 340.15 2 2
4 7 1998.36 24 11.72 3240 911 2.33 / 341.06 2 2
5 13 1728.16 49 12.31 2879 1737 4.07 / 342.79 2 2
6 13 421.04 49 13.72 990 666 4.74 / 343.46 2 3
7 8 0.12 170 14.29 314 763 5.50 / 344.22 2 4
Average= 4.85
(KJ/cycle)

Cycle 69 GMT 26/ 8/2018 13:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 25 14.51 486 176 0.18 / 333.64 2 2
2 3 1019.76 1 11.65 1916 22 0.20 / 333.66 2 2
3 12 2002.76 36 11.09 3148 1257 1.46 / 334.92 2 2
4 7 2000.00 24 11.76 3237 914 2.37 / 335.83 2 2
5 13 1457.80 49 12.60 2497 1542 3.91 / 337.37 2 2
6 13 339.48 49 13.86 863 586 4.50 / 337.96 2 3
7 8 0.00 170 14.30 315 766 5.26 / 338.72 2 3
Average= 4.84
(KJ/cycle)

Cycle 68 GMT 16/ 8/2018 13: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 25 14.53 482 175 0.18 / 328.22 2 2
2 12 2001.24 36 11.06 3168 1261 1.44 / 329.48 2 2
3 7 1998.68 24 11.80 3240 918 2.35 / 330.40 2 2
4 13 1577.88 49 12.52 2640 1620 3.97 / 332.02 2 2
5 13 426.00 49 13.73 1003 675 4.65 / 332.69 2 3
6 8 -0.04 170 14.29 317 770 5.42 / 333.46 2 4
Average= 4.83
(KJ/cycle)

Cycle 67 GMT 6/ 8/2018 13:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 24 14.53 474 165 0.17 / 322.92 2 2
2 12 2002.08 36 11.22 3169 1280 1.45 / 324.20 2 2
3 7 1999.32 24 11.80 3260 923 2.37 / 325.12 2 2
4 13 1568.08 49 12.52 2642 1621 3.99 / 326.74 2 2
5 13 291.56 49 13.93 793 541 4.53 / 327.28 2 3
6 8 0.04 170 14.29 313 760 5.29 / 328.04 2 7
Average= 4.82
(KJ/cycle)

Cycle 66 GMT 27/ 7/2018 13:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 25 14.53 462 168 0.17 / 317.60 2 2
2 12 2001.08 36 11.14 3181 1276 1.44 / 318.88 2 2
3 7 1998.44 24 11.83 3257 925 2.37 / 319.80 2 2
4 13 1578.92 49 12.54 2654 1631 4.00 / 321.43 2 2
5 13 305.20 49 13.91 816 556 4.56 / 321.99 2 3
6 8 0.00 170 14.29 313 760 5.32 / 322.75 2 4
Average= 4.82
(KJ/cycle)

Cycle 65 GMT 17/ 7/2018 13:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 24 14.53 484 169 0.17 / 312.31 2 2
2 3 1030.24 1 13.01 1952 25 0.19 / 312.34 2 2
3 12 2007.44 36 11.27 3204 1300 1.49 / 313.63 2 2
4 7 2004.72 24 11.90 3260 931 2.43 / 314.57 2 2
5 13 1460.04 49 12.69 2463 1532 3.96 / 316.10 2 2
6 13 316.20 49 13.89 835 568 4.52 / 316.67 2 3
7 8 0.04 170 14.29 317 770 5.30 / 317.44 2 4
Average= 4.81
(KJ/cycle)

Cycle 64 GMT 7/ 7/2018 13: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 24 14.55 465 162 0.16 / 306.72 2 2
2 7 2003.16 50 11.42 3241 1851 2.01 / 308.58 2 2
3 13 1744.00 49 12.42 2911 1772 3.78 / 310.35 2 2
4 13 484.84 49 13.67 1108 742 4.53 / 311.09 2 2
5 13 49.28 49 14.33 399 280 4.81 / 311.37 2 2
6 8 -0.08 170 14.23 319 772 5.58 / 312.14 2 5
Average= 4.80
(KJ/cycle)

Cycle 63 GMT 27/ 6/2018 12:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 26 14.53 482 182 0.18 / 301.18 2 2
2 3 932.60 -1 15.43 0 0 0.00 / 301.18 2 2
3 7 2003.32 50 11.50 3242 1864 2.05 / 303.05 2 2
4 13 1739.20 49 12.44 2893 1763 3.81 / 304.81 2 2
5 13 485.60 49 13.67 1113 746 4.56 / 305.55 2 3
6 13 12.48 49 14.41 337 238 4.79 / 305.79 2 3
7 8 0.00 170 14.19 319 770 5.56 / 306.56 2 8
Average= 4.79
(KJ/cycle)

Cycle 62 GMT 17/ 6/2018 12:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 25 14.56 482 175 0.18 / 295.39 2 2
2 3 1026.76 1 12.99 1946 25 0.20 / 295.42 2 2
3 7 2003.96 50 11.63 3246 1888 2.09 / 297.31 2 2
4 13 1875.28 49 12.30 3063 1846 3.93 / 299.15 2 2
5 13 591.88 49 13.57 1262 839 4.77 / 299.99 2 3
6 13 20.04 49 14.41 332 234 5.01 / 300.23 2 2
7 8 -0.08 170 14.23 320 774 5.78 / 301.00 2 5
Average= 4.78
(KJ/cycle)

Cycle 61 GMT 7/ 6/2018 12:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 25 14.58 475 173 0.17 / 290.03 2 2
2 7 2003.24 50 11.68 3245 1895 2.07 / 291.93 2 2
3 13 1746.04 49 12.48 2885 1764 3.83 / 293.69 2 2
4 13 492.00 49 13.68 1124 753 4.59 / 294.44 2 3
5 8 -0.12 170 14.30 318 773 5.36 / 295.22 2 6
Average= 4.76
(KJ/cycle)

Cycle 60 GMT 28/ 5/2018 11:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 25 14.60 468 171 0.17 / 285.04 2 2
2 7 2005.40 50 11.78 3252 1915 2.09 / 286.96 2 2
3 13 1748.80 28 12.82 2924 1050 3.14 / 288.01 2 2
4 13 1014.44 28 13.40 1889 709 3.84 / 288.71 2 2
5 13 156.52 28 14.26 578 231 4.08 / 288.95 2 2
6 13 43.36 28 14.42 382 154 4.23 / 289.10 2 2
7 8 0.04 170 14.31 312 759 4.99 / 289.86 2 3
Average= 4.75
(KJ/cycle)

Cycle 59 GMT 18/ 5/2018 10:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 24 14.62 468 164 0.16 / 280.17 2 2
2 7 2002.16 50 11.87 3238 1922 2.09 / 282.09 2 2
3 13 1598.40 28 12.96 2698 979 3.07 / 283.07 2 2
4 13 891.44 28 13.51 1724 652 3.72 / 283.72 2 2
5 13 154.64 28 14.24 581 232 3.95 / 283.95 2 2
6 13 41.16 28 14.40 384 155 4.10 / 284.11 2 2
7 8 -0.12 170 14.29 314 763 4.87 / 284.87 2 5
Average= 4.75
(KJ/cycle)

Cycle 58 GMT 8/ 5/2018 10: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 24 14.59 466 163 0.16 / 275.37 2 2
2 7 2006.36 50 11.94 3248 1939 2.10 / 277.30 2 2
3 13 1472.68 28 13.07 2516 921 3.02 / 278.23 2 2
4 13 889.04 28 13.52 1715 649 3.67 / 278.87 2 2
5 13 141.56 28 14.27 558 223 3.90 / 279.10 2 2
6 13 36.76 28 14.42 373 151 4.05 / 279.25 2 2
7 8 -0.20 170 14.29 311 756 4.80 / 280.00 2 6
Average= 4.75
(KJ/cycle)

Cycle 57 GMT 28/ 4/2018 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 24 14.62 458 161 0.16 / 270.45 2 2
2 7 2003.40 50 12.02 3249 1953 2.11 / 272.40 2 2
3 13 1742.36 28 12.89 2910 1050 3.16 / 273.45 2 2
4 13 854.04 28 13.56 1663 631 3.80 / 274.09 2 2
5 13 131.00 28 14.30 534 214 4.01 / 274.30 2 2
6 13 31.32 28 14.43 364 147 4.16 / 274.45 2 2
7 8 -0.16 170 14.30 311 756 4.91 / 275.20 2 6
Average= 4.74
(KJ/cycle)

Cycle 56 GMT 18/ 4/2018 8:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 24 14.61 470 165 0.16 / 265.63 2 2
2 7 2000.60 50 12.13 3250 1971 2.14 / 267.60 2 2
3 13 1474.96 28 13.11 2523 926 3.06 / 268.53 2 2
4 13 893.24 28 13.55 1725 654 3.72 / 269.18 2 2
5 13 135.20 28 14.30 542 217 3.93 / 269.40 2 2
6 13 16.64 28 14.46 336 136 4.07 / 269.54 2 2
7 8 -0.08 170 14.28 311 755 4.82 / 270.29 2 5
Average= 4.74
(KJ/cycle)

Cycle 55 GMT 8/ 4/2018 7:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 25 14.61 457 167 0.17 / 260.55 2 2
2 3 950.12 -1 15.40 0 0 0.00 / 260.55 2 2
3 7 2001.16 51 12.20 3260 2028 2.20 / 262.58 2 2
4 13 1868.08 28 12.80 3084 1105 3.30 / 263.69 2 2
5 13 799.92 28 13.62 1585 604 3.91 / 264.29 2 2
6 13 195.64 28 14.21 648 258 4.16 / 264.55 2 2
7 13 36.88 28 14.43 375 152 4.31 / 264.70 2 2
8 8 -0.04 170 14.30 314 763 5.08 / 265.47 2 3
Average= 4.74
(KJ/cycle)

Cycle 54 GMT 29/ 3/2018 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 24 14.65 479 168 0.17 / 255.64 2 2
2 3 1033.00 1 13.64 1952 27 0.20 / 255.67 2 2
3 7 2002.04 50 12.32 3252 2003 2.20 / 257.67 2 2
4 13 1600.32 28 13.09 2696 988 3.19 / 258.66 2 2
5 13 845.36 28 13.62 1638 625 3.81 / 259.29 2 2
6 13 118.64 28 14.36 493 198 4.01 / 259.49 2 2
7 13 24.60 28 14.46 345 140 4.15 / 259.63 2 2
8 8 -0.04 170 14.33 313 762 4.91 / 260.39 2 3
Average= 4.73
(KJ/cycle)

Cycle 53 GMT 19/ 3/2018 6: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 24 14.65 459 161 0.16 / 250.72 2 2
2 3 1024.40 1 13.46 1945 26 0.19 / 250.74 2 2
3 7 2003.28 51 12.35 3255 2050 2.24 / 252.79 2 2
4 13 1464.60 28 13.18 2499 922 3.16 / 253.72 2 2
5 13 889.12 28 13.59 1701 647 3.81 / 254.36 2 2
6 13 133.00 28 14.36 517 208 4.02 / 254.57 2 2
7 13 26.24 28 14.47 356 144 4.16 / 254.72 2 2
8 8 0.12 170 14.34 312 761 4.92 / 255.48 2 5
Average= 4.73
(KJ/cycle)

Cycle 52 GMT 9/ 3/2018 5:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 24 14.67 458 161 0.16 / 245.93 2 2
2 7 2001.72 51 12.37 3250 2050 2.21 / 247.98 2 2
3 13 1583.80 28 13.10 2683 984 3.20 / 248.96 2 2
4 13 843.68 28 13.62 1647 628 3.82 / 249.59 2 2
5 13 117.32 28 14.37 509 205 4.03 / 249.80 2 2
6 8 0.00 170 14.38 311 760 4.79 / 250.56 2 6
Average= 4.73
(KJ/cycle)

Cycle 51 GMT 27/ 2/2018 4:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 24 14.66 459 161 0.16 / 240.96 2 2
2 7 2006.32 50 12.37 3253 2012 2.17 / 242.97 2 2
3 13 1591.00 28 13.08 2694 987 3.16 / 243.96 2 2
4 13 983.76 28 13.52 1851 701 3.86 / 244.66 2 2
5 13 112.44 28 14.38 501 202 4.06 / 244.86 2 2
6 13 24.96 28 14.47 353 143 4.21 / 245.01 2 2
7 8 -0.08 170 14.35 312 761 4.97 / 245.77 2 2
Average= 4.73
(KJ/cycle)

Cycle 50 GMT 17/ 2/2018 4:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 24 14.66 463 163 0.16 / 236.05 2 2
2 7 2001.84 51 12.35 3244 2043 2.21 / 238.09 2 2
3 13 1577.12 28 13.10 2669 979 3.19 / 239.07 2 2
4 13 831.76 28 13.63 1635 624 3.81 / 239.69 2 2
5 13 108.48 28 14.38 493 199 4.01 / 239.89 2 2
6 13 24.00 28 14.48 353 143 4.15 / 240.03 2 2
7 8 -0.08 170 14.35 314 766 4.92 / 240.80 2 4
Average= 4.72
(KJ/cycle)

Cycle 49 GMT 7/ 2/2018 3:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 24 14.67 461 162 0.16 / 231.08 2 2
2 7 2002.40 50 12.31 3259 2006 2.17 / 233.08 2 2
3 13 1735.96 28 12.98 2895 1052 3.22 / 234.13 2 2
4 13 853.96 28 13.60 1666 634 3.85 / 234.77 2 2
5 13 119.12 28 14.37 515 207 4.06 / 234.97 2 2
6 13 23.96 28 14.47 354 143 4.21 / 235.12 2 2
7 8 -0.04 170 14.35 314 766 4.97 / 235.88 2 4
Average= 4.72
(KJ/cycle)

Cycle 48 GMT 28/ 1/2018 3:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 25 14.65 464 170 0.17 / 226.16 2 2
2 3 967.52 -1 15.40 0 0 0.00 / 226.16 2 2
3 7 2000.88 50 12.27 3246 1991 2.16 / 228.15 2 2
4 13 1593.72 28 13.05 2717 993 3.15 / 229.15 2 2
5 13 859.16 28 13.60 1674 637 3.79 / 229.78 2 2
6 13 133.96 28 14.36 541 218 4.01 / 230.00 2 2
7 13 26.72 28 14.49 359 146 4.15 / 230.15 2 2
8 8 -0.08 170 14.37 313 765 4.92 / 230.91 2 4
Average= 4.71
(KJ/cycle)

Cycle 47 GMT 18/ 1/2018 3: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 24 14.66 480 169 0.17 / 221.20 2 2
2 3 1028.96 1 13.69 1963 27 0.20 / 221.23 2 2
3 7 2001.00 50 12.24 3250 1989 2.18 / 223.22 2 2
4 13 1718.64 28 12.96 2870 1041 3.23 / 224.26 2 2
5 13 822.80 28 13.62 1620 618 3.84 / 224.88 2 2
6 13 133.12 28 14.37 539 217 4.06 / 225.09 2 2
7 13 14.32 28 14.53 336 137 4.20 / 225.23 2 2
8 8 -0.12 170 14.37 313 765 4.96 / 225.99 2 4
Average= 4.71
(KJ/cycle)

Cycle 46 GMT 8/ 1/2018 2:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 24 14.67 462 163 0.16 / 216.41 2 2
2 7 2004.04 51 12.14 3257 2017 2.18 / 218.43 2 2
3 13 1592.52 28 13.00 2708 986 3.16 / 219.41 2 2
4 13 846.44 28 13.58 1656 630 3.79 / 220.04 2 2
5 13 128.36 28 14.37 534 215 4.01 / 220.26 2 2
6 8 0.04 170 14.40 316 774 4.78 / 221.03 2 3
Average= 4.70
(KJ/cycle)

Cycle 45 GMT 29/12/2017 1:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 24 14.66 472 166 0.17 / 211.54 2 2
2 7 2004.16 51 12.12 3245 2006 2.17 / 213.55 2 2
3 13 1594.32 28 13.02 2705 986 3.16 / 214.54 2 2
4 13 728.72 28 13.69 1487 570 3.73 / 215.11 2 2
5 13 138.96 28 14.36 555 223 3.95 / 215.33 2 2
6 13 14.40 28 14.53 341 139 4.09 / 215.47 2 2
7 8 -0.12 170 14.36 320 781 4.87 / 216.25 2 5
Average= 4.70
(KJ/cycle)

Cycle 44 GMT 19/12/2017 1:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 25 14.67 465 171 0.17 / 206.83 2 2
2 3 928.92 -1 15.39 0 0 0.00 / 206.83 2 2
3 7 2004.08 50 12.11 3260 1974 2.14 / 208.81 2 2
4 13 1586.00 28 13.00 2709 986 3.13 / 209.79 2 2
5 13 732.32 28 13.68 1495 573 3.70 / 210.37 2 2
6 13 145.12 28 14.37 560 225 3.93 / 210.59 2 2
7 8 -0.12 170 14.42 320 784 4.71 / 211.38 2 3
Average= 4.70
(KJ/cycle)

Cycle 43 GMT 9/12/2017 0:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 24 14.68 493 174 0.17 / 201.94 2 2
2 3 1047.28 1 13.97 1958 27 0.20 / 201.96 2 2
3 7 2002.48 51 12.15 3254 2016 2.22 / 203.98 2 2
4 13 1602.72 28 13.03 2716 991 3.21 / 204.97 2 2
5 13 998.96 28 13.49 1887 713 3.92 / 205.68 2 2
6 13 116.04 28 14.43 507 205 4.13 / 205.89 2 2
7 8 -0.04 170 14.44 316 776 4.90 / 206.66 2 4
Average= 4.70
(KJ/cycle)

Cycle 42 GMT 29/11/2017 0: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 24 14.71 467 165 0.16 / 197.11 2 2
2 7 2003.20 51 12.18 3262 2026 2.19 / 199.14 2 2
3 13 1595.00 28 13.05 2701 987 3.18 / 200.12 2 2
4 13 863.56 28 13.62 1686 643 3.82 / 200.77 2 2
5 13 127.36 28 14.44 529 214 4.03 / 200.98 2 2
6 8 0.00 170 14.45 318 781 4.82 / 201.76 2 3
Average= 4.69
(KJ/cycle)

Cycle 41 GMT 18/11/2017 23:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 23 14.75 463 157 0.16 / 192.35 2 2
2 7 2001.44 47 12.30 3267 1889 2.05 / 194.24 2 2
3 13 1736.16 29 12.98 2908 1095 3.14 / 195.34 2 2
4 13 873.16 29 13.63 1685 666 3.81 / 196.00 2 2
5 13 131.44 29 14.46 519 218 4.02 / 196.22 2 2
6 8 0.04 160 14.49 313 726 4.75 / 196.95 2 4
Average= 4.69
(KJ/cycle)

Cycle 40 GMT 8/11/2017 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 25 14.70 478 176 0.18 / 187.50 2 2
2 3 950.08 -1 15.38 0 0 0.00 / 187.50 2 2
3 7 2002.08 48 12.36 3259 1933 2.11 / 189.43 2 2
4 13 1726.76 29 13.04 2892 1094 3.20 / 190.53 2 2
5 13 961.12 29 13.59 1832 722 3.92 / 191.25 2 2
6 13 114.68 29 14.49 511 215 4.14 / 191.46 2 2
7 8 0.04 160 14.50 316 733 4.87 / 192.20 2 3
Average= 4.69
(KJ/cycle)

Cycle 39 GMT 29/10/2017 22:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 25 14.73 491 181 0.18 / 182.60 2 2
2 7 2001.28 47 12.43 3255 1902 2.08 / 184.50 2 2
3 13 1724.40 32 13.04 2873 1199 3.28 / 185.70 2 2
4 13 706.68 32 13.78 1461 644 3.93 / 186.34 2 2
5 13 114.60 32 14.47 509 236 4.16 / 186.58 2 2
6 8 0.00 160 14.47 322 745 4.91 / 187.32 2 3
Average= 4.68
(KJ/cycle)

Cycle 38 GMT 19/10/2017 21:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 23 14.74 489 166 0.17 / 177.63 2 2
2 3 1053.72 1 14.22 1999 28 0.19 / 177.66 2 2
3 7 2016.36 47 12.48 3263 1914 2.11 / 179.57 2 2
4 13 1601.28 32 13.18 2697 1137 3.25 / 180.71 2 2
5 13 850.84 32 13.70 1657 726 3.97 / 181.44 2 2
6 13 100.36 32 14.50 486 226 4.20 / 181.66 2 2
7 8 0.16 160 14.46 327 757 4.95 / 182.42 2 3
Average= 4.68
(KJ/cycle)

Cycle 37 GMT 9/10/2017 20:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 23 14.75 475 161 0.16 / 172.75 2 2
2 7 2005.20 47 12.52 3271 1925 2.09 / 174.67 2 2
3 13 1597.16 32 13.19 2693 1137 3.22 / 175.81 2 2
4 13 724.12 32 13.80 1488 657 3.88 / 176.47 2 2
5 13 114.08 32 14.48 519 240 4.12 / 176.71 2 2
6 8 0.08 160 14.46 327 757 4.88 / 177.46 2 4
Average= 4.67
(KJ/cycle)

Cycle 36 GMT 29/ 9/2017 20: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 23 14.78 478 162 0.16 / 167.81 2 2
2 7 2005.56 47 12.55 3259 1922 2.08 / 169.74 2 2
3 13 1737.52 32 13.12 2885 1211 3.30 / 170.95 2 2
4 13 722.36 32 13.82 1472 651 3.95 / 171.60 2 2
5 13 109.64 32 14.51 494 229 4.18 / 171.83 2 2
6 8 -0.04 160 14.47 328 759 4.94 / 172.59 2 6
Average= 4.66
(KJ/cycle)

Cycle 35 GMT 19/ 9/2017 19: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 23 14.78 474 161 0.16 / 162.87 2 2
2 7 2001.00 47 12.61 3257 1930 2.09 / 164.80 2 2
3 13 1601.60 32 13.22 2713 1148 3.24 / 165.95 2 2
4 13 835.72 32 13.75 1651 726 3.97 / 166.67 2 3
5 13 85.44 32 14.54 469 218 4.18 / 166.89 2 2
6 8 0.00 160 14.48 327 758 4.94 / 167.65 2 5
Average= 4.66
(KJ/cycle)

Cycle 34 GMT 9/ 9/2017 18:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 24 14.76 482 171 0.17 / 158.00 2 2
2 3 942.24 -1 15.40 0 0 0.00 / 158.00 2 2
3 7 2000.88 47 12.66 3257 1938 2.11 / 159.94 2 2
4 13 1588.52 32 13.26 2696 1144 3.25 / 161.09 2 2
5 13 693.40 32 13.88 1443 641 3.89 / 161.73 2 3
6 13 100.92 32 14.55 486 226 4.12 / 161.95 2 2
7 8 -0.12 160 14.51 326 757 4.88 / 162.71 2 4
Average= 4.65
(KJ/cycle)

Cycle 33 GMT 30/ 8/2017 17:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 23 14.79 491 167 0.17 / 152.97 2 2
2 3 1059.24 2 14.39 2008 58 0.22 / 153.03 2 2
3 3 1018.96 1 14.24 1952 28 0.25 / 153.06 2 2
4 7 2003.04 48 12.69 3255 1983 2.24 / 155.04 2 2
5 13 1596.36 32 13.28 2692 1144 3.38 / 156.19 2 2
6 13 709.36 32 13.88 1469 652 4.03 / 156.84 2 3
7 13 111.72 32 14.55 509 237 4.27 / 157.08 2 2
8 8 0.04 160 14.52 326 757 5.03 / 157.83 2 5
Average= 4.64
(KJ/cycle)

Cycle 32 GMT 20/ 8/2017 16:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 23 14.79 473 161 0.16 / 148.08 2 2
2 7 2006.48 47 12.71 3266 1951 2.11 / 150.03 2 2
3 13 1597.60 32 13.28 2700 1147 3.26 / 151.17 2 2
4 13 700.96 32 13.90 1447 644 3.90 / 151.82 2 3
5 13 110.32 32 14.56 505 235 4.14 / 152.05 2 2
6 8 0.08 160 14.52 324 753 4.89 / 152.81 2 8
Average= 4.63
(KJ/cycle)

Cycle 31 GMT 10/ 8/2017 15:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 23 14.77 487 165 0.17 / 143.23 2 2
2 3 969.80 -1 15.42 0 0 0.00 / 143.23 2 2
3 7 2002.96 47 12.77 3263 1958 2.12 / 145.18 2 2
4 13 1469.56 32 13.38 2520 1079 3.20 / 146.26 2 2
5 13 728.56 32 13.89 1490 662 3.87 / 146.93 2 3
6 13 114.44 32 14.56 513 239 4.10 / 147.17 2 2
7 8 -0.12 160 14.52 323 750 4.85 / 147.92 2 4
Average= 4.62
(KJ/cycle)

Cycle 30 GMT 31/ 7/2017 14:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 23 14.79 478 163 0.16 / 138.19 2 2
2 7 2000.08 47 12.78 3264 1961 2.12 / 140.15 2 2
3 13 1722.24 32 13.24 2870 1216 3.34 / 141.36 2 2
4 13 821.64 32 13.84 1618 717 4.06 / 142.08 2 2
5 13 100.56 32 14.59 490 229 4.28 / 142.31 2 2
6 8 0.16 160 14.54 323 751 5.04 / 143.06 2 5
Average= 4.61
(KJ/cycle)

Cycle 29 GMT 21/ 7/2017 13:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 23 14.82 475 162 0.16 / 133.08 2 2
2 7 1997.96 47 12.83 3264 1968 2.13 / 135.05 2 2
3 13 1585.92 39 13.25 2670 1380 3.51 / 136.43 2 2
4 13 510.64 39 14.04 1164 637 4.15 / 137.06 2 3
5 13 72.08 39 14.58 446 254 4.40 / 137.32 2 3
6 8 -0.20 150 14.51 325 707 5.11 / 138.03 2 6
Average= 4.60
(KJ/cycle)

Cycle 28 GMT 11/ 7/2017 12:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 24 14.82 482 171 0.17 / 127.83 2 2
2 3 941.72 -1 15.46 0 0 0.00 / 127.83 2 2
3 7 2004.96 47 12.84 3280 1979 2.15 / 129.81 2 2
4 13 1601.24 38 13.25 2694 1356 3.51 / 131.17 2 2
5 13 528.08 38 14.02 1193 636 4.14 / 131.80 2 3
6 13 47.88 38 14.64 402 224 4.37 / 132.03 2 2
7 8 -0.12 190 14.48 324 891 5.26 / 132.92 2 6
Average= 4.58
(KJ/cycle)

Cycle 27 GMT 1/ 7/2017 11: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 23 14.83 485 165 0.17 / 122.43 2 2
2 3 1048.80 1 14.49 1994 29 0.19 / 122.46 2 2
3 7 2002.60 47 12.86 3271 1977 2.17 / 124.44 2 2
4 13 1731.88 38 13.19 2878 1443 3.61 / 125.88 2 2
5 13 509.92 38 14.05 1148 613 4.23 / 126.49 2 3
6 13 72.84 38 14.58 454 252 4.48 / 126.74 2 3
7 8 -0.28 190 14.45 334 917 5.40 / 127.66 2 7
Average= 4.56
(KJ/cycle)

Cycle 26 GMT 21/ 6/2017 10:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 23 14.83 461 157 0.16 / 117.19 2 2
2 7 2002.12 47 12.91 3269 1984 2.14 / 119.18 2 2
3 13 1583.00 38 13.28 2668 1346 3.49 / 120.52 2 2
4 13 508.60 38 14.05 1158 618 4.11 / 121.14 2 3
5 13 45.12 38 14.64 404 225 4.33 / 121.37 2 3
6 8 -0.24 190 14.49 326 898 5.23 / 122.26 2 5
Average= 4.53
(KJ/cycle)

Cycle 25 GMT 11/ 6/2017 9:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 23 14.83 475 162 0.16 / 112.02 2 2
2 7 1996.32 47 12.93 3253 1977 2.14 / 113.99 2 2
3 13 1445.72 38 13.37 2517 1279 3.42 / 115.27 2 2
4 13 542.44 38 14.03 1214 647 4.06 / 115.92 2 3
5 13 49.28 38 14.65 401 223 4.29 / 116.14 2 2
6 8 -0.24 190 14.49 324 892 5.18 / 117.04 2 4
Average= 4.50
(KJ/cycle)

Cycle 24 GMT 1/ 6/2017 8:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 24 14.81 472 168 0.17 / 106.83 2 2
2 3 963.72 -1 15.51 0 0 0.00 / 106.83 2 2
3 7 1994.56 47 12.96 3249 1979 2.15 / 108.81 2 2
4 13 1466.04 38 13.37 2531 1286 3.43 / 110.10 2 2
5 13 526.44 38 14.05 1182 631 4.06 / 110.73 2 3
6 13 48.28 38 14.66 396 221 4.28 / 110.95 2 3
7 8 -0.20 190 14.49 329 906 5.19 / 111.86 2 5
Average= 4.47
(KJ/cycle)

Cycle 23 GMT 22/ 5/2017 6:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 23 14.83 489 167 0.17 / 101.53 2 2
2 3 1043.64 1 14.52 1988 29 0.20 / 101.56 2 2
3 7 2002.08 47 12.98 3276 1999 2.19 / 103.56 2 2
4 13 1579.48 36 13.34 2660 1277 3.47 / 104.83 2 2
5 13 652.80 36 13.96 1387 697 4.17 / 105.53 2 3
6 13 66.68 36 14.63 437 230 4.40 / 105.76 2 2
7 8 -0.12 190 14.50 328 904 5.30 / 106.67 2 5
Average= 4.44
(KJ/cycle)

Cycle 22 GMT 12/ 5/2017 6: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 23 14.84 466 159 0.16 / 96.25 2 2
2 7 1995.28 47 13.00 3242 1981 2.14 / 98.23 2 2
3 13 1581.36 36 13.33 2687 1289 3.43 / 99.52 2 2
4 13 659.92 36 13.96 1396 702 4.13 / 100.22 2 3
5 13 67.84 36 14.63 442 233 4.36 / 100.46 2 3
6 8 -0.16 190 14.49 329 906 5.27 / 101.36 2 3
Average= 4.41
(KJ/cycle)

Cycle 21 GMT 2/ 5/2017 4:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 24 14.84 465 166 0.17 / 90.92 2 2
2 3 948.96 -1 15.54 0 0 0.00 / 90.92 2 2
3 7 1994.68 47 13.01 3254 1990 2.16 / 92.91 2 2
4 13 1713.84 36 13.26 2884 1377 3.53 / 94.29 2 2
5 13 621.48 36 14.00 1338 674 4.21 / 94.96 2 3
6 13 58.92 36 14.64 429 226 4.43 / 95.19 2 2
7 8 -0.16 190 14.50 328 904 5.34 / 96.09 2 5
Average= 4.37
(KJ/cycle)

Cycle 20 GMT 22/ 4/2017 3:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 24 14.85 485 173 0.17 / 85.57 2 2
2 7 1995.32 47 13.02 3247 1987 2.16 / 87.55 2 2
3 13 1462.88 36 13.41 2523 1218 3.38 / 88.77 2 2
4 13 855.60 36 13.82 1690 841 4.22 / 89.61 2 3
5 13 58.52 36 14.64 433 228 4.45 / 89.84 2 3
6 8 -0.20 190 14.49 333 917 5.36 / 90.76 2 8
Average= 4.32
(KJ/cycle)

Cycle 19 GMT 12/ 4/2017 2:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 23 14.84 491 168 0.17 / 80.55 2 2
2 3 1054.84 1 14.60 2013 29 0.20 / 80.58 2 2
3 7 1995.28 44 13.08 3247 1869 2.07 / 82.45 2 2
4 13 1711.12 30 13.34 2849 1140 3.21 / 83.59 2 2
5 13 806.44 30 13.91 1613 673 3.88 / 84.27 2 3
6 13 94.08 30 14.62 489 214 4.09 / 84.48 2 2
7 8 -0.20 190 14.52 331 913 5.01 / 85.39 2 6
Average= 4.27
(KJ/cycle)

Cycle 18 GMT 2/ 4/2017 1:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 23 14.87 471 161 0.16 / 75.60 2 2
2 7 1996.64 44 13.08 3230 1859 2.02 / 77.46 2 2
3 13 1597.28 30 13.39 2708 1088 3.11 / 78.55 2 2
4 13 854.56 30 13.87 1683 700 3.81 / 79.25 2 2
5 13 99.56 30 14.63 494 217 4.02 / 79.47 2 2
6 8 -0.20 190 14.50 334 920 4.95 / 80.39 2 8
Average= 4.23
(KJ/cycle)

Cycle 17 GMT 23/ 3/2017 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 24 14.86 476 170 0.17 / 70.64 2 2
2 3 942.20 -1 15.57 0 0 0.00 / 70.64 2 2
3 7 1988.56 44 13.10 3268 1884 2.05 / 72.53 2 2
4 13 1585.92 30 13.40 2699 1085 3.14 / 73.61 2 2
5 13 831.68 30 13.89 1652 688 3.83 / 74.30 2 3
6 13 92.68 30 14.64 491 216 4.04 / 74.52 2 2
7 8 -0.20 190 14.51 336 926 4.97 / 75.44 2 5
Average= 4.19
(KJ/cycle)

Cycle 16 GMT 12/ 3/2017 22:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 23 14.87 493 169 0.17 / 65.75 2 2
2 3 1047.84 1 14.60 2001 29 0.20 / 65.78 2 2
3 7 1988.88 44 13.09 3236 1864 2.06 / 67.64 2 2
4 13 1488.60 30 13.46 2576 1040 3.10 / 68.68 2 2
5 13 789.24 30 13.93 1587 663 3.77 / 69.35 2 2
6 13 75.08 30 14.68 455 200 3.97 / 69.55 2 2
7 8 -0.12 190 14.52 336 927 4.89 / 70.47 2 11
Average= 4.15
(KJ/cycle)

Cycle 15 GMT 2/ 3/2017 21:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 24 14.89 479 171 0.17 / 60.88 2 2
2 3 954.68 -1 15.57 0 0 0.00 / 60.88 2 2
3 7 1997.68 44 13.09 3259 1877 2.05 / 62.76 2 2
4 13 1585.72 30 13.41 2706 1089 3.14 / 63.85 2 2
5 13 705.04 30 13.99 1474 619 3.76 / 64.47 2 3
6 13 58.52 30 14.72 431 190 3.95 / 64.66 2 2
7 8 -0.20 190 14.53 334 922 4.87 / 65.58 2 4
Average= 4.10
(KJ/cycle)

Cycle 14 GMT 20/ 2/2017 19:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 22 14.87 504 165 0.16 / 56.14 2 2
2 3 1055.76 1 14.63 2001 29 0.19 / 56.17 2 2
3 7 1990.56 44 13.09 3286 1893 2.09 / 58.06 2 2
4 13 1475.80 30 13.46 2577 1041 3.13 / 59.10 2 2
5 13 521.40 30 14.14 1197 508 3.64 / 59.61 2 3
6 13 59.56 30 14.74 428 189 3.82 / 59.80 2 2
7 8 -0.16 190 14.56 330 913 4.74 / 60.71 2 4
Average= 4.05
(KJ/cycle)

Cycle 13 GMT 10/ 2/2017 18: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 22 14.89 497 163 0.16 / 51.50 2 2
2 7 1985.68 46 13.05 3265 1960 2.12 / 53.46 2 2
3 13 1345.84 26 13.57 2421 854 2.98 / 54.32 2 2
4 13 691.92 26 14.04 1472 537 3.51 / 54.85 2 2
5 13 120.08 26 14.64 541 206 3.72 / 55.06 2 2
6 8 0.00 190 14.56 331 916 4.64 / 55.98 2 5
Average= 4.00
(KJ/cycle)

Cycle 12 GMT 31/ 1/2017 16: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 22 14.93 423 139 0.14 / 46.91 2 2
2 7 1982.84 46 13.06 3199 1922 2.06 / 48.83 2 2
3 13 1476.64 26 13.53 2521 887 2.95 / 49.72 2 2
4 13 785.96 26 13.99 1538 559 3.51 / 50.28 2 3
5 13 102.64 26 14.71 451 172 3.68 / 50.45 2 2
6 13 22.08 26 14.82 313 121 3.80 / 50.57 2 2
7 8 -0.20 190 14.60 277 768 4.57 / 51.34 2 3
Average= 3.95
(KJ/cycle)

Cycle 11 GMT 21/ 1/2017 14:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 23 14.97 416 143 0.14 / 42.58 2 2
2 7 1979.68 45 13.07 3202 1883 2.03 / 44.47 2 2
3 13 1463.08 26 13.54 2500 880 2.91 / 45.35 2 2
4 13 643.84 26 14.10 1323 485 3.39 / 45.83 2 3
5 13 116.64 26 14.71 467 179 3.57 / 46.01 2 2
6 8 -0.04 190 14.65 273 760 4.33 / 46.77 2 5
Average= 3.90
(KJ/cycle)

Cycle 10 GMT 11/ 1/2017 12:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 22 14.96 422 139 0.14 / 38.23 2 2
2 3 1023.24 1 14.61 1929 28 0.17 / 38.26 2 2
3 7 1982.88 45 13.07 3209 1887 2.05 / 40.15 2 2
4 13 1464.44 26 13.55 2493 878 2.93 / 41.03 2 2
5 13 636.12 26 14.11 1313 482 3.41 / 41.51 2 2
6 13 118.12 26 14.73 464 178 3.59 / 41.69 2 2
7 8 0.00 190 14.67 271 755 4.35 / 42.44 2 5
Average= 3.86
(KJ/cycle)

Cycle 9 GMT 1/ 1/2017 10:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 22 14.97 424 140 0.14 / 33.81 2 2
2 7 1980.48 46 13.09 3191 1921 2.06 / 35.73 2 2
3 13 1459.28 26 13.54 2487 876 2.94 / 36.60 2 2
4 13 532.20 26 14.18 1157 427 3.36 / 37.03 2 3
5 13 127.92 26 14.69 491 188 3.55 / 37.22 2 2
6 13 27.04 26 14.85 316 122 3.67 / 37.34 2 2
7 8 -0.20 190 14.63 271 753 4.43 / 38.09 2 4
Average= 3.81
(KJ/cycle)

Cycle 8 GMT 22/12/2016 8:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 22 14.97 417 137 0.14 / 29.49 2 2
2 7 1978.96 45 13.07 3187 1874 2.01 / 31.36 2 2
3 13 1344.68 26 13.60 2322 821 2.83 / 32.18 2 2
4 13 785.56 26 13.97 1530 556 3.39 / 32.74 2 3
5 13 105.12 26 14.72 452 173 3.56 / 32.91 2 2
6 8 -0.12 190 14.65 272 757 4.32 / 33.67 2 6
Average= 3.74
(KJ/cycle)

Cycle 7 GMT 12/12/2016 7:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 21 14.97 422 133 0.13 / 25.03 2 2
2 3 1019.52 1 14.55 1912 28 0.16 / 25.05 2 2
3 7 1966.92 46 13.05 3167 1901 2.06 / 26.96 2 2
4 13 1572.04 26 13.46 2631 921 2.98 / 27.88 2 2
5 13 709.84 26 14.02 1426 520 3.50 / 28.40 2 3
6 13 139.36 26 14.67 516 197 3.70 / 28.59 2 2
7 8 -0.16 190 14.64 272 757 4.46 / 29.35 2 5
Average= 3.67
(KJ/cycle)

Cycle 6 GMT 2/12/2016 5:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 20 14.99 418 125 0.13 / 20.74 2 2
2 3 1046.72 1 14.61 1946 28 0.15 / 20.77 2 2
3 7 1971.36 46 13.05 3166 1901 2.05 / 22.67 2 2
4 13 1317.40 26 13.58 2282 806 2.86 / 23.48 2 2
5 13 650.64 26 14.05 1339 489 3.35 / 23.97 2 3
6 13 116.68 26 14.72 469 179 3.53 / 24.15 2 2
7 8 -0.04 190 14.66 268 746 4.28 / 24.89 2 4
Average= 3.56
(KJ/cycle)

Cycle 5 GMT 22/11/2016 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 24 14.95 421 151 0.15 / 16.51 2 2
2 3 839.00 -3 15.62 0 0 0.00 / 16.51 2 2
3 3 965.76 -1 15.61 0 0 0.00 / 16.51 2 2
4 7 1966.32 45 13.02 3176 1861 2.01 / 18.37 2 2
5 13 1446.20 26 13.48 2458 861 2.87 / 19.23 2 2
6 13 620.92 26 14.07 1290 472 3.35 / 19.70 2 3
7 13 118.68 26 14.73 462 177 3.52 / 19.88 2 2
8 8 0.36 190 14.67 265 739 4.26 / 20.62 2 7
Average= 3.44
(KJ/cycle)

Cycle 4 GMT 12/11/2016 2: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 22 14.94 442 145 0.15 / 12.54 2 2
2 7 1506.40 46 13.41 2546 1571 1.72 / 14.11 2 2
3 13 1387.16 26 13.58 2393 845 2.56 / 14.95 2 2
4 13 649.60 26 14.07 1333 488 3.05 / 15.44 2 2
5 13 92.08 26 14.78 424 163 3.21 / 15.60 2 2
6 8 -0.04 190 14.64 272 757 3.97 / 16.36 2 4
Average= 3.27
(KJ/cycle)

Cycle 3 GMT 11/11/2016 2:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 22 14.91 416 136 0.14 / 8.64 2 2
2 7 1507.20 46 13.35 2546 1563 1.70 / 10.21 2 2
3 13 1149.44 26 13.63 2063 731 2.43 / 10.94 2 2
4 13 724.36 26 13.94 1443 523 2.95 / 11.46 2 2
5 13 113.88 26 14.71 459 176 3.13 / 11.64 2 2
6 8 0.04 190 14.61 271 752 3.88 / 12.39 2 8
Average= 3.10
(KJ/cycle)

Cycle 2 GMT 10/11/2016 3: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 24 14.83 419 149 0.15 / 4.55 2 2
2 3 887.72 -2 15.60 0 0 0.00 / 4.55 2 2
3 7 1507.32 74 13.04 2531 2442 2.59 / 6.99 2 2
4 13 613.64 25 14.01 1268 444 3.04 / 7.43 2 2
5 13 94.72 25 14.71 423 156 3.19 / 7.59 2 2
6 8 0.00 240 14.58 263 920 4.11 / 8.51 2 5
Average= 2.84
(KJ/cycle)

Cycle 1 GMT 9/11/2016 3:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 24 14.86 417 149 0.15 / 1.58 2 2
2 3 884.44 -2 15.56 0 0 0.00 / 1.58 2 2
3 7 993.84 74 13.23 1808 1770 1.92 / 3.35 2 2
4 13 66.24 25 14.66 372 136 2.06 / 3.48 2 2
5 8 -0.20 240 14.51 262 912 2.97 / 4.40 2 6
Average= 2.20
(KJ/cycle)

Cycle 0 GMT 8/11/2016 16: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 135.96 24 14.45 442 153 0.15 / 0.15 2 2
2 7 145.92 74 14.39 450 479 0.63 / 0.63 2 2
3 8 0.24 240 14.75 225 796 1.43 / 1.43 2 2
Average= 1.43
(KJ/cycle)