SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 38 | 10.54 | 426 | 171 | 0.17 / 1460.99 | 2 | 2 |
2 | 3 | 1029.00 | 1 | 8.26 | 1692 | 14 | 0.18 / 1461.01 | 2 | 2 |
3 | 3 | 1014.12 | 1 | 8.41 | 1688 | 14 | 0.20 / 1461.02 | 2 | 2 |
4 | 12 | 1147.16 | 75 | 7.58 | 1823 | 1036 | 1.24 / 1462.06 | 2 | 2 |
5 | 7 | 1147.64 | 22 | 7.63 | 1836 | 308 | 1.54 / 1462.36 | 2 | 2 |
6 | 13 | 1062.92 | 45 | 7.89 | 1718 | 610 | 2.15 / 1462.97 | 2 | 2 |
7 | 13 | 794.48 | 45 | 8.59 | 1359 | 525 | 2.68 / 1463.50 | 2 | 2 |
8 | 13 | 17.76 | 45 | 10.74 | 271 | 131 | 2.81 / 1463.63 | 2 | 2 |
9 | 8 | 0.16 | 180 | 10.77 | 263 | 510 | 3.32 / 1464.14 | 2 | 2 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 39 | 10.56 | 431 | 178 | 0.18 / 1457.83 | 2 | 2 |
2 | 3 | 953.84 | -1 | 10.56 | 431 | 0 | 0.00 / 1457.83 | 2 | 2 |
3 | 3 | 1021.28 | 1 | 8.60 | 1691 | 15 | 0.19 / 1457.85 | 2 | 2 |
4 | 12 | 1144.12 | 75 | 7.72 | 1823 | 1056 | 1.25 / 1458.90 | 2 | 2 |
5 | 7 | 1144.12 | 22 | 7.85 | 1832 | 316 | 1.56 / 1459.22 | 2 | 2 |
6 | 13 | 1060.88 | 45 | 8.04 | 1719 | 622 | 2.19 / 1459.84 | 2 | 2 |
7 | 13 | 657.24 | 45 | 9.05 | 1177 | 479 | 2.67 / 1460.32 | 2 | 2 |
8 | 8 | -0.08 | 180 | 10.81 | 256 | 498 | 3.16 / 1460.82 | 2 | 2 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 36 | 10.63 | 425 | 163 | 0.16 / 1454.44 | 2 | 2 |
2 | 3 | 1049.84 | 2 | 8.69 | 1738 | 30 | 0.19 / 1454.47 | 2 | 2 |
3 | 3 | 1014.52 | 1 | 8.84 | 1700 | 15 | 0.21 / 1454.48 | 2 | 2 |
4 | 12 | 1141.44 | 75 | 7.95 | 1826 | 1089 | 1.30 / 1455.57 | 2 | 2 |
5 | 7 | 1140.48 | 22 | 8.01 | 1835 | 323 | 1.62 / 1455.90 | 2 | 2 |
6 | 13 | 1041.36 | 45 | 8.27 | 1697 | 632 | 2.25 / 1456.53 | 2 | 2 |
7 | 13 | 645.80 | 45 | 9.21 | 1161 | 481 | 2.73 / 1457.01 | 2 | 2 |
8 | 13 | 12.80 | 45 | 10.81 | 266 | 129 | 2.86 / 1457.14 | 2 | 2 |
9 | 8 | 0.12 | 180 | 10.82 | 266 | 518 | 3.38 / 1457.66 | 2 | 2 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 36 | 10.81 | 431 | 168 | 0.17 / 1449.60 | 2 | 2 |
2 | 12 | 1131.08 | 5 | 8.38 | 1841 | 77 | 0.24 / 1449.68 | 2 | 2 |
3 | 12 | 1724.40 | 75 | 6.64 | 2641 | 1315 | 1.56 / 1450.99 | 2 | 2 |
4 | 7 | 1720.96 | 22 | 6.49 | 2634 | 376 | 1.94 / 1451.37 | 2 | 2 |
5 | 13 | 1626.04 | 45 | 6.93 | 2511 | 783 | 2.72 / 1452.15 | 2 | 2 |
6 | 13 | 1505.92 | 45 | 7.31 | 2352 | 774 | 3.49 / 1452.93 | 2 | 2 |
7 | 13 | 949.20 | 45 | 8.60 | 1608 | 622 | 4.12 / 1453.55 | 2 | 2 |
8 | 13 | 85.80 | 45 | 10.61 | 397 | 190 | 4.30 / 1453.74 | 2 | 2 |
9 | 8 | 0.16 | 180 | 10.83 | 276 | 538 | 4.84 / 1454.28 | 2 | 2 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 34 | 11.05 | 424 | 159 | 0.16 / 1446.22 | 2 | 2 |
2 | 10 | 1018.28 | 4 | 9.33 | 1697 | 63 | 0.22 / 1446.29 | 2 | 2 |
3 | 12 | 1138.28 | 75 | 7.82 | 1816 | 1065 | 1.29 / 1447.35 | 2 | 2 |
4 | 7 | 1137.16 | 22 | 8.01 | 1824 | 321 | 1.61 / 1447.67 | 2 | 2 |
5 | 13 | 1043.92 | 45 | 8.39 | 1696 | 640 | 2.25 / 1448.31 | 2 | 2 |
6 | 13 | 518.32 | 45 | 9.75 | 987 | 433 | 2.68 / 1448.75 | 2 | 2 |
7 | 13 | 14.12 | 45 | 11.06 | 269 | 134 | 2.82 / 1448.88 | 2 | 2 |
8 | 8 | -0.16 | 180 | 11.00 | 279 | 552 | 3.37 / 1449.43 | 2 | 2 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 36 | 11.25 | 418 | 169 | 0.17 / 1442.93 | 2 | 2 |
2 | 12 | 1113.52 | 75 | 8.06 | 1780 | 1076 | 1.25 / 1444.00 | 2 | 2 |
3 | 7 | 1112.88 | 22 | 8.44 | 1794 | 333 | 1.58 / 1444.34 | 2 | 2 |
4 | 13 | 1033.80 | 45 | 8.68 | 1686 | 659 | 2.24 / 1445.00 | 2 | 2 |
5 | 13 | 344.68 | 45 | 10.36 | 744 | 347 | 2.58 / 1445.34 | 2 | 2 |
6 | 13 | 32.88 | 45 | 11.14 | 317 | 159 | 2.74 / 1445.50 | 2 | 2 |
7 | 8 | 0.28 | 180 | 11.18 | 280 | 563 | 3.31 / 1446.07 | 2 | 2 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 31 | 11.60 | 426 | 153 | 0.15 / 1439.49 | 2 | 2 |
2 | 10 | 1012.68 | 5 | 10.27 | 1711 | 88 | 0.24 / 1439.58 | 2 | 2 |
3 | 3 | 1028.88 | 1 | 10.20 | 1735 | 18 | 0.26 / 1439.60 | 2 | 2 |
4 | 12 | 1127.48 | 75 | 8.56 | 1810 | 1162 | 1.42 / 1440.76 | 2 | 2 |
5 | 7 | 1125.00 | 22 | 8.79 | 1819 | 352 | 1.77 / 1441.11 | 2 | 2 |
6 | 13 | 1012.72 | 45 | 9.09 | 1662 | 680 | 2.45 / 1441.79 | 2 | 2 |
7 | 13 | 451.88 | 45 | 10.38 | 895 | 418 | 2.87 / 1442.21 | 2 | 2 |
8 | 8 | -0.16 | 180 | 11.35 | 270 | 552 | 3.42 / 1442.76 | 2 | 2 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 29 | 11.93 | 434 | 150 | 0.15 / 1434.17 | 2 | 2 |
2 | 10 | 1014.52 | 6 | 10.36 | 1728 | 107 | 0.26 / 1434.27 | 2 | 2 |
3 | 12 | 1141.48 | 5 | 10.13 | 1873 | 95 | 0.35 / 1434.37 | 2 | 2 |
4 | 12 | 1945.24 | 75 | 7.53 | 2945 | 1663 | 2.02 / 1436.03 | 2 | 2 |
5 | 7 | 1939.40 | 23 | 7.37 | 2958 | 501 | 2.52 / 1436.53 | 2 | 2 |
6 | 13 | 1807.76 | 45 | 8.03 | 2776 | 1003 | 3.52 / 1437.54 | 2 | 2 |
7 | 13 | 1220.32 | 45 | 9.27 | 2001 | 835 | 4.35 / 1438.37 | 2 | 2 |
8 | 13 | 330.60 | 45 | 11.02 | 760 | 377 | 4.73 / 1438.75 | 2 | 2 |
9 | 8 | -0.08 | 180 | 11.67 | 281 | 590 | 5.32 / 1439.34 | 2 | 2 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 27 | 12.38 | 444 | 148 | 0.15 / 1430.70 | 2 | 2 |
2 | 10 | 1001.24 | 7 | 11.31 | 1718 | 136 | 0.28 / 1430.84 | 2 | 2 |
3 | 12 | 1134.96 | 75 | 8.02 | 1812 | 1090 | 1.37 / 1431.93 | 2 | 2 |
4 | 7 | 1134.28 | 22 | 9.53 | 1850 | 388 | 1.76 / 1432.32 | 2 | 2 |
5 | 13 | 1023.88 | 45 | 9.56 | 1686 | 725 | 2.49 / 1433.04 | 2 | 2 |
6 | 13 | 311.80 | 45 | 11.44 | 711 | 366 | 2.85 / 1433.41 | 2 | 2 |
7 | 8 | 0.04 | 180 | 12.05 | 280 | 607 | 3.46 / 1434.02 | 2 | 3 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 29 | 13.23 | 453 | 174 | 0.17 / 1427.16 | 2 | 2 |
2 | 10 | 1010.12 | 4 | 12.38 | 1753 | 87 | 0.26 / 1427.25 | 2 | 2 |
3 | 3 | 954.68 | -1 | 12.38 | 1753 | 0 | 0.09 / 1427.25 | 2 | 2 |
4 | 12 | 1145.88 | 75 | 8.03 | 1823 | 1098 | 1.36 / 1428.34 | 2 | 2 |
5 | 7 | 1144.96 | 22 | 9.78 | 1869 | 402 | 1.76 / 1428.75 | 2 | 2 |
6 | 13 | 1042.44 | 45 | 9.79 | 1721 | 758 | 2.52 / 1429.51 | 2 | 2 |
7 | 13 | 343.88 | 45 | 11.82 | 762 | 405 | 2.92 / 1429.91 | 2 | 2 |
8 | 8 | 0.00 | 180 | 12.46 | 287 | 644 | 3.57 / 1430.55 | 2 | 2 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 29 | 13.77 | 445 | 178 | 0.18 / 1423.70 | 2 | 2 |
2 | 12 | 1142.16 | 75 | 8.35 | 1827 | 1144 | 1.32 / 1424.85 | 2 | 2 |
3 | 7 | 1140.68 | 22 | 10.19 | 1864 | 418 | 1.74 / 1425.26 | 2 | 2 |
4 | 13 | 1032.12 | 45 | 10.37 | 1710 | 798 | 2.54 / 1426.06 | 2 | 2 |
5 | 13 | 70.48 | 45 | 13.23 | 387 | 230 | 2.77 / 1426.29 | 2 | 2 |
6 | 8 | -0.04 | 180 | 13.06 | 295 | 693 | 3.46 / 1426.99 | 2 | 3 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 28 | 13.85 | 457 | 177 | 0.18 / 1418.38 | 2 | 2 |
2 | 3 | 1020.60 | 1 | 11.78 | 1763 | 21 | 0.20 / 1418.41 | 2 | 2 |
3 | 12 | 1118.76 | 5 | 11.63 | 1881 | 109 | 0.31 / 1418.51 | 2 | 2 |
4 | 12 | 1985.92 | 75 | 8.50 | 3023 | 1927 | 2.23 / 1420.44 | 2 | 2 |
5 | 7 | 1979.36 | 22 | 9.59 | 3040 | 641 | 2.88 / 1421.08 | 2 | 2 |
6 | 13 | 1418.36 | 45 | 10.76 | 2304 | 1116 | 3.99 / 1422.20 | 2 | 2 |
7 | 13 | 495.76 | 45 | 12.77 | 1022 | 587 | 4.58 / 1422.79 | 2 | 2 |
8 | 8 | -0.08 | 180 | 13.59 | 302 | 739 | 5.32 / 1423.52 | 2 | 4 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 29 | 13.93 | 446 | 180 | 0.18 / 1414.35 | 2 | 2 |
2 | 3 | 939.28 | -1 | 13.93 | 446 | 0 | 0.00 / 1414.35 | 2 | 2 |
3 | 12 | 1129.60 | 75 | 5.95 | 1728 | 771 | 0.95 / 1415.12 | 2 | 2 |
4 | 7 | 1135.24 | 22 | 9.71 | 1872 | 400 | 1.35 / 1415.52 | 2 | 2 |
5 | 13 | 1178.16 | 45 | 9.13 | 1908 | 784 | 2.14 / 1416.30 | 2 | 2 |
6 | 13 | 1084.00 | 45 | 10.04 | 1794 | 811 | 2.95 / 1417.12 | 2 | 2 |
7 | 13 | 183.56 | 45 | 13.46 | 572 | 346 | 3.29 / 1417.46 | 2 | 2 |
8 | 8 | -0.04 | 180 | 13.72 | 302 | 746 | 4.04 / 1418.21 | 2 | 4 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 29 | 14.06 | 450 | 183 | 0.18 / 1410.37 | 2 | 2 |
2 | 12 | 1125.80 | 75 | 5.93 | 1735 | 772 | 0.96 / 1411.14 | 2 | 2 |
3 | 7 | 1130.36 | 22 | 9.78 | 1868 | 402 | 1.36 / 1411.54 | 2 | 2 |
4 | 13 | 1170.84 | 45 | 9.49 | 1901 | 812 | 2.17 / 1412.35 | 2 | 2 |
5 | 13 | 1054.52 | 45 | 10.59 | 1755 | 836 | 3.01 / 1413.19 | 2 | 2 |
6 | 13 | 40.00 | 45 | 13.90 | 364 | 228 | 3.23 / 1413.42 | 2 | 2 |
7 | 8 | 0.08 | 180 | 13.85 | 302 | 753 | 3.99 / 1414.17 | 2 | 3 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 29 | 14.10 | 455 | 186 | 0.19 / 1406.82 | 2 | 2 |
2 | 12 | 1124.36 | 75 | 7.55 | 1781 | 1008 | 1.19 / 1407.83 | 2 | 2 |
3 | 7 | 1124.52 | 22 | 10.24 | 1848 | 416 | 1.61 / 1408.24 | 2 | 2 |
4 | 13 | 1023.64 | 45 | 10.86 | 1733 | 847 | 2.46 / 1409.09 | 2 | 2 |
5 | 13 | 156.20 | 45 | 13.74 | 538 | 333 | 2.79 / 1409.42 | 2 | 2 |
6 | 8 | 0.04 | 180 | 13.98 | 303 | 762 | 3.55 / 1410.18 | 2 | 4 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 28 | 14.06 | 449 | 177 | 0.18 / 1401.39 | 2 | 2 |
2 | 12 | 1120.12 | 5 | 11.57 | 1889 | 109 | 0.29 / 1401.50 | 2 | 2 |
3 | 12 | 2001.72 | 75 | 8.62 | 3040 | 1965 | 2.25 / 1403.46 | 2 | 2 |
4 | 7 | 1995.28 | 22 | 10.07 | 3093 | 685 | 2.94 / 1404.15 | 2 | 2 |
5 | 13 | 1428.28 | 45 | 11.62 | 2326 | 1216 | 4.15 / 1405.37 | 2 | 2 |
6 | 13 | 337.20 | 45 | 13.55 | 799 | 487 | 4.64 / 1405.85 | 2 | 2 |
7 | 8 | 0.08 | 180 | 14.03 | 308 | 778 | 5.42 / 1406.63 | 2 | 4 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 29 | 14.13 | 444 | 182 | 0.18 / 1397.30 | 2 | 2 |
2 | 12 | 1127.52 | 75 | 5.87 | 1720 | 757 | 0.94 / 1398.06 | 2 | 2 |
3 | 7 | 1132.88 | 22 | 9.83 | 1867 | 404 | 1.34 / 1398.46 | 2 | 2 |
4 | 13 | 1164.92 | 45 | 9.98 | 1919 | 862 | 2.20 / 1399.32 | 2 | 2 |
5 | 13 | 1051.00 | 45 | 10.99 | 1779 | 880 | 3.08 / 1400.20 | 2 | 2 |
6 | 13 | 44.36 | 45 | 13.99 | 374 | 235 | 3.32 / 1400.44 | 2 | 2 |
7 | 8 | -0.20 | 180 | 14.03 | 307 | 775 | 4.10 / 1401.21 | 2 | 9 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 29 | 14.14 | 449 | 184 | 0.18 / 1393.60 | 2 | 2 |
2 | 12 | 1115.36 | 75 | 6.57 | 1735 | 855 | 1.04 / 1394.46 | 2 | 2 |
3 | 7 | 1118.88 | 22 | 10.06 | 1847 | 409 | 1.45 / 1394.87 | 2 | 2 |
4 | 13 | 1053.28 | 45 | 10.79 | 1769 | 859 | 2.31 / 1395.73 | 2 | 2 |
5 | 13 | 514.12 | 45 | 12.99 | 1050 | 614 | 2.92 / 1396.34 | 2 | 2 |
6 | 8 | -0.08 | 180 | 14.05 | 307 | 776 | 3.70 / 1397.12 | 2 | 2 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 28 | 14.21 | 439 | 175 | 0.17 / 1390.04 | 2 | 2 |
2 | 3 | 1016.32 | 1 | 11.75 | 1750 | 21 | 0.20 / 1390.06 | 2 | 2 |
3 | 12 | 1128.00 | 75 | 7.77 | 1793 | 1045 | 1.24 / 1391.10 | 2 | 2 |
4 | 7 | 1127.04 | 22 | 10.42 | 1860 | 426 | 1.67 / 1391.53 | 2 | 2 |
5 | 13 | 1018.72 | 45 | 11.47 | 1721 | 888 | 2.55 / 1392.42 | 2 | 2 |
6 | 13 | 59.08 | 45 | 14.04 | 369 | 233 | 2.79 / 1392.65 | 2 | 2 |
7 | 8 | -0.24 | 180 | 14.11 | 303 | 770 | 3.56 / 1393.42 | 2 | 4 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 30 | 14.13 | 438 | 186 | 0.19 / 1384.75 | 2 | 2 |
2 | 3 | 964.48 | -1 | 14.13 | 438 | 0 | 0.00 / 1384.75 | 2 | 2 |
3 | 3 | 1028.68 | 1 | 11.68 | 1759 | 21 | 0.21 / 1384.77 | 2 | 2 |
4 | 12 | 1126.44 | 5 | 11.61 | 1883 | 109 | 0.32 / 1384.88 | 2 | 2 |
5 | 12 | 1997.84 | 75 | 8.92 | 3048 | 2039 | 2.35 / 1386.92 | 2 | 2 |
6 | 7 | 1991.04 | 22 | 10.27 | 3085 | 697 | 3.05 / 1387.62 | 2 | 2 |
7 | 13 | 1394.20 | 45 | 11.91 | 2287 | 1226 | 4.28 / 1388.84 | 2 | 2 |
8 | 13 | 63.28 | 45 | 14.08 | 396 | 251 | 4.53 / 1389.09 | 2 | 2 |
9 | 8 | -0.16 | 180 | 14.17 | 302 | 770 | 5.30 / 1389.86 | 2 | 7 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 28 | 14.16 | 445 | 176 | 0.18 / 1380.84 | 2 | 2 |
2 | 12 | 1133.36 | 75 | 6.26 | 1738 | 816 | 0.99 / 1381.65 | 2 | 2 |
3 | 7 | 1136.92 | 22 | 10.08 | 1874 | 416 | 1.41 / 1382.07 | 2 | 2 |
4 | 13 | 1095.04 | 45 | 10.88 | 1816 | 889 | 2.30 / 1382.96 | 2 | 2 |
5 | 13 | 963.32 | 45 | 11.70 | 1643 | 865 | 3.16 / 1383.82 | 2 | 2 |
6 | 8 | 0.12 | 180 | 14.10 | 292 | 741 | 3.90 / 1384.56 | 2 | 3 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 29 | 14.17 | 444 | 182 | 0.18 / 1377.13 | 2 | 2 |
2 | 3 | 967.40 | -1 | 14.17 | 444 | 0 | 0.00 / 1377.13 | 2 | 2 |
3 | 3 | 1023.68 | 1 | 11.53 | 1762 | 20 | 0.20 / 1377.15 | 2 | 2 |
4 | 12 | 1143.80 | 75 | 6.84 | 1782 | 914 | 1.12 / 1378.07 | 2 | 2 |
5 | 7 | 1145.96 | 22 | 10.28 | 1886 | 427 | 1.54 / 1378.49 | 2 | 2 |
6 | 13 | 1072.04 | 45 | 11.26 | 1786 | 905 | 2.45 / 1379.40 | 2 | 2 |
7 | 13 | 369.56 | 45 | 13.48 | 821 | 498 | 2.95 / 1379.90 | 2 | 2 |
8 | 8 | -0.12 | 180 | 14.14 | 301 | 766 | 3.71 / 1380.66 | 2 | 2 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 28 | 14.18 | 470 | 187 | 0.19 / 1373.50 | 2 | 2 |
2 | 3 | 1018.24 | 1 | 11.96 | 1768 | 21 | 0.21 / 1373.52 | 2 | 2 |
3 | 12 | 1133.80 | 75 | 7.97 | 1800 | 1076 | 1.28 / 1374.59 | 2 | 2 |
4 | 7 | 1134.00 | 22 | 10.57 | 1874 | 436 | 1.72 / 1375.03 | 2 | 2 |
5 | 13 | 1029.80 | 45 | 11.74 | 1736 | 917 | 2.64 / 1375.95 | 2 | 2 |
6 | 13 | 55.20 | 45 | 14.09 | 360 | 228 | 2.86 / 1376.17 | 2 | 2 |
7 | 8 | -0.20 | 180 | 14.16 | 304 | 775 | 3.64 / 1376.95 | 2 | 8 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 28 | 14.14 | 460 | 182 | 0.18 / 1368.13 | 2 | 2 |
2 | 3 | 1036.36 | 1 | 11.90 | 1788 | 21 | 0.20 / 1368.16 | 2 | 2 |
3 | 12 | 1125.08 | 5 | 11.63 | 1888 | 110 | 0.31 / 1368.27 | 2 | 2 |
4 | 12 | 2001.88 | 75 | 8.95 | 3057 | 2052 | 2.37 / 1370.32 | 2 | 2 |
5 | 7 | 1995.00 | 22 | 10.27 | 3103 | 701 | 3.07 / 1371.02 | 2 | 2 |
6 | 13 | 1404.36 | 45 | 12.00 | 2305 | 1245 | 4.31 / 1372.26 | 2 | 2 |
7 | 13 | 70.00 | 45 | 14.09 | 405 | 257 | 4.57 / 1372.52 | 2 | 2 |
8 | 8 | -0.08 | 180 | 14.19 | 309 | 789 | 5.36 / 1373.31 | 2 | 4 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 28 | 14.12 | 451 | 178 | 0.18 / 1364.35 | 2 | 2 |
2 | 12 | 1126.04 | 75 | 6.61 | 1741 | 863 | 1.04 / 1365.22 | 2 | 2 |
3 | 7 | 1129.00 | 22 | 10.25 | 1864 | 420 | 1.46 / 1365.64 | 2 | 2 |
4 | 13 | 1075.04 | 45 | 11.22 | 1803 | 910 | 2.37 / 1366.55 | 2 | 2 |
5 | 13 | 515.92 | 45 | 13.15 | 1051 | 622 | 2.99 / 1367.17 | 2 | 2 |
6 | 8 | -0.08 | 180 | 14.12 | 308 | 783 | 3.78 / 1367.95 | 2 | 3 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 27 | 14.14 | 451 | 172 | 0.17 / 1360.53 | 2 | 2 |
2 | 3 | 1020.88 | 1 | 11.68 | 1768 | 21 | 0.19 / 1360.55 | 2 | 2 |
3 | 12 | 1134.84 | 75 | 7.08 | 1773 | 941 | 1.13 / 1361.49 | 2 | 2 |
4 | 7 | 1138.44 | 22 | 10.37 | 1886 | 430 | 1.56 / 1361.92 | 2 | 2 |
5 | 13 | 1059.12 | 45 | 11.50 | 1774 | 918 | 2.48 / 1362.84 | 2 | 2 |
6 | 13 | 474.08 | 45 | 13.31 | 975 | 584 | 3.07 / 1363.42 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.15 | 296 | 754 | 3.82 / 1364.18 | 2 | 3 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 29 | 14.15 | 458 | 188 | 0.19 / 1356.88 | 2 | 2 |
2 | 3 | 958.44 | -1 | 14.15 | 458 | 0 | 0.00 / 1356.88 | 2 | 2 |
3 | 3 | 1018.72 | 1 | 11.84 | 1773 | 21 | 0.21 / 1356.90 | 2 | 2 |
4 | 12 | 1129.48 | 75 | 8.09 | 1805 | 1095 | 1.30 / 1358.00 | 2 | 2 |
5 | 7 | 1128.52 | 22 | 10.68 | 1875 | 441 | 1.74 / 1358.44 | 2 | 2 |
6 | 13 | 1020.64 | 45 | 11.93 | 1728 | 928 | 2.67 / 1359.37 | 2 | 2 |
7 | 13 | 24.52 | 45 | 14.14 | 328 | 209 | 2.88 / 1359.58 | 2 | 2 |
8 | 8 | -0.08 | 180 | 14.18 | 305 | 778 | 3.66 / 1360.35 | 2 | 6 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 28 | 14.11 | 450 | 178 | 0.18 / 1351.55 | 2 | 2 |
2 | 12 | 1121.52 | 5 | 11.69 | 1892 | 111 | 0.29 / 1351.66 | 2 | 2 |
3 | 12 | 1998.96 | 75 | 8.92 | 3050 | 2040 | 2.33 / 1353.70 | 2 | 2 |
4 | 7 | 1992.16 | 22 | 10.40 | 3088 | 707 | 3.04 / 1354.40 | 2 | 2 |
5 | 13 | 1410.40 | 45 | 12.07 | 2313 | 1256 | 4.29 / 1355.66 | 2 | 2 |
6 | 13 | 64.32 | 45 | 14.10 | 397 | 252 | 4.54 / 1355.91 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.20 | 306 | 782 | 5.33 / 1356.70 | 2 | 5 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 28 | 14.10 | 469 | 185 | 0.19 / 1347.74 | 2 | 2 |
2 | 12 | 1133.04 | 75 | 6.89 | 1755 | 907 | 1.09 / 1348.65 | 2 | 2 |
3 | 7 | 1135.16 | 22 | 10.38 | 1874 | 428 | 1.52 / 1349.07 | 2 | 2 |
4 | 13 | 1064.92 | 45 | 11.47 | 1799 | 929 | 2.45 / 1350.00 | 2 | 2 |
5 | 13 | 472.76 | 45 | 13.30 | 988 | 591 | 3.04 / 1350.59 | 2 | 2 |
6 | 8 | -0.12 | 180 | 14.14 | 305 | 776 | 3.82 / 1351.37 | 2 | 5 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 26 | 14.15 | 447 | 164 | 0.16 / 1344.11 | 2 | 2 |
2 | 3 | 1044.92 | 2 | 12.16 | 1792 | 44 | 0.21 / 1344.16 | 2 | 2 |
3 | 3 | 1018.84 | 1 | 11.54 | 1755 | 20 | 0.23 / 1344.18 | 2 | 2 |
4 | 12 | 1126.04 | 75 | 7.37 | 1765 | 976 | 1.20 / 1345.15 | 2 | 2 |
5 | 7 | 1126.92 | 22 | 10.49 | 1869 | 431 | 1.64 / 1345.58 | 2 | 2 |
6 | 13 | 1026.72 | 45 | 11.77 | 1735 | 919 | 2.55 / 1346.50 | 2 | 2 |
7 | 13 | 133.88 | 45 | 13.97 | 480 | 302 | 2.86 / 1346.80 | 2 | 2 |
8 | 8 | 0.16 | 180 | 14.18 | 294 | 750 | 3.61 / 1347.55 | 2 | 4 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 28 | 14.15 | 447 | 177 | 0.18 / 1340.42 | 2 | 2 |
2 | 3 | 966.52 | -1 | 14.15 | 447 | 0 | 0.00 / 1340.42 | 2 | 2 |
3 | 12 | 1147.48 | 75 | 8.30 | 1826 | 1137 | 1.31 / 1341.56 | 2 | 2 |
4 | 7 | 1146.04 | 22 | 10.79 | 1892 | 449 | 1.76 / 1342.01 | 2 | 2 |
5 | 13 | 1035.20 | 45 | 12.11 | 1742 | 949 | 2.71 / 1342.96 | 2 | 2 |
6 | 13 | 26.60 | 45 | 14.14 | 335 | 213 | 2.93 / 1343.17 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.19 | 303 | 774 | 3.70 / 1343.95 | 2 | 5 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 28 | 14.08 | 449 | 177 | 0.18 / 1335.20 | 2 | 2 |
2 | 12 | 1119.76 | 5 | 11.72 | 1889 | 111 | 0.29 / 1335.32 | 2 | 2 |
3 | 12 | 1998.64 | 75 | 8.95 | 3052 | 2049 | 2.34 / 1337.36 | 2 | 2 |
4 | 7 | 1991.60 | 22 | 10.45 | 3092 | 711 | 3.05 / 1338.08 | 2 | 2 |
5 | 13 | 1266.16 | 45 | 12.37 | 2117 | 1178 | 4.23 / 1339.25 | 2 | 2 |
6 | 13 | 34.72 | 45 | 14.16 | 344 | 219 | 4.44 / 1339.47 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.21 | 303 | 775 | 5.22 / 1340.25 | 2 | 5 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 28 | 14.07 | 464 | 183 | 0.18 / 1331.46 | 2 | 2 |
2 | 12 | 1137.40 | 75 | 7.10 | 1774 | 945 | 1.13 / 1332.40 | 2 | 2 |
3 | 7 | 1139.40 | 22 | 10.50 | 1890 | 437 | 1.56 / 1332.84 | 2 | 2 |
4 | 13 | 1056.28 | 45 | 11.73 | 1780 | 940 | 2.50 / 1333.78 | 2 | 2 |
5 | 13 | 319.56 | 45 | 13.65 | 764 | 469 | 2.97 / 1334.25 | 2 | 2 |
6 | 8 | -0.08 | 180 | 14.15 | 307 | 782 | 3.75 / 1335.03 | 2 | 3 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 28 | 14.10 | 459 | 181 | 0.18 / 1327.83 | 2 | 2 |
2 | 12 | 1116.84 | 75 | 7.58 | 1756 | 998 | 1.18 / 1328.83 | 2 | 2 |
3 | 7 | 1117.80 | 22 | 10.59 | 1854 | 432 | 1.61 / 1329.26 | 2 | 2 |
4 | 13 | 1019.64 | 45 | 11.82 | 1742 | 927 | 2.54 / 1330.18 | 2 | 2 |
5 | 13 | 130.84 | 45 | 13.94 | 498 | 312 | 2.85 / 1330.50 | 2 | 2 |
6 | 8 | 0.04 | 180 | 14.15 | 305 | 777 | 3.63 / 1331.27 | 2 | 4 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 28 | 14.08 | 472 | 186 | 0.19 / 1324.34 | 2 | 2 |
2 | 12 | 1108.92 | 75 | 8.61 | 1781 | 1150 | 1.34 / 1325.49 | 2 | 2 |
3 | 7 | 1106.92 | 22 | 10.95 | 1840 | 443 | 1.78 / 1325.93 | 2 | 2 |
4 | 13 | 986.60 | 45 | 12.24 | 1697 | 935 | 2.71 / 1326.87 | 2 | 2 |
5 | 8 | -0.16 | 180 | 14.15 | 305 | 777 | 3.49 / 1327.65 | 2 | 2 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 28 | 14.08 | 460 | 181 | 0.18 / 1319.02 | 2 | 2 |
2 | 12 | 1100.28 | 5 | 11.80 | 1858 | 110 | 0.29 / 1319.13 | 2 | 2 |
3 | 12 | 1996.72 | 75 | 9.04 | 3055 | 2071 | 2.36 / 1321.20 | 2 | 2 |
4 | 7 | 1989.84 | 22 | 10.46 | 3081 | 709 | 3.07 / 1321.91 | 2 | 2 |
5 | 13 | 1274.08 | 45 | 12.38 | 2129 | 1186 | 4.26 / 1323.10 | 2 | 2 |
6 | 13 | 69.92 | 45 | 14.08 | 415 | 263 | 4.52 / 1323.36 | 2 | 2 |
7 | 8 | 0.08 | 180 | 14.16 | 311 | 793 | 5.31 / 1324.15 | 2 | 4 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 27 | 14.03 | 462 | 175 | 0.18 / 1315.34 | 2 | 2 |
2 | 3 | 1031.84 | 1 | 12.07 | 1783 | 22 | 0.20 / 1315.36 | 2 | 2 |
3 | 12 | 1141.00 | 75 | 7.33 | 1779 | 978 | 1.17 / 1316.34 | 2 | 2 |
4 | 7 | 1143.24 | 22 | 10.61 | 1896 | 443 | 1.62 / 1316.78 | 2 | 2 |
5 | 13 | 1050.88 | 45 | 11.87 | 1777 | 949 | 2.57 / 1317.73 | 2 | 2 |
6 | 13 | 196.52 | 45 | 13.86 | 578 | 360 | 2.93 / 1318.09 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.14 | 296 | 753 | 3.68 / 1318.84 | 2 | 7 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 27 | 14.08 | 468 | 178 | 0.18 / 1311.70 | 2 | 2 |
2 | 3 | 1025.68 | 1 | 12.13 | 1761 | 21 | 0.20 / 1311.72 | 2 | 2 |
3 | 12 | 1136.24 | 75 | 7.65 | 1791 | 1028 | 1.23 / 1312.75 | 2 | 2 |
4 | 7 | 1136.44 | 22 | 10.71 | 1880 | 443 | 1.67 / 1313.19 | 2 | 2 |
5 | 13 | 1040.16 | 45 | 11.99 | 1756 | 947 | 2.62 / 1314.14 | 2 | 2 |
6 | 13 | 60.72 | 45 | 14.06 | 391 | 247 | 2.86 / 1314.38 | 2 | 2 |
7 | 8 | 0.04 | 180 | 14.15 | 305 | 777 | 3.64 / 1315.16 | 2 | 7 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 29 | 14.06 | 466 | 190 | 0.19 / 1307.94 | 2 | 2 |
2 | 3 | 963.04 | -1 | 14.06 | 466 | 0 | 0.00 / 1307.94 | 2 | 2 |
3 | 3 | 1015.64 | 1 | 11.78 | 1755 | 21 | 0.21 / 1307.96 | 2 | 2 |
4 | 12 | 1138.64 | 75 | 8.59 | 1812 | 1167 | 1.38 / 1309.13 | 2 | 2 |
5 | 7 | 1136.72 | 22 | 10.99 | 1878 | 454 | 1.83 / 1309.58 | 2 | 2 |
6 | 13 | 1028.28 | 45 | 12.26 | 1752 | 967 | 2.80 / 1310.55 | 2 | 2 |
7 | 13 | 19.28 | 45 | 14.14 | 325 | 207 | 3.01 / 1310.76 | 2 | 2 |
8 | 8 | 0.04 | 180 | 14.15 | 300 | 764 | 3.77 / 1311.52 | 2 | 5 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 27 | 14.04 | 457 | 173 | 0.17 / 1302.70 | 2 | 2 |
2 | 3 | 1027.24 | 1 | 12.05 | 1779 | 21 | 0.19 / 1302.72 | 2 | 2 |
3 | 12 | 1130.12 | 5 | 11.77 | 1900 | 112 | 0.31 / 1302.83 | 2 | 2 |
4 | 12 | 1996.80 | 75 | 8.97 | 3040 | 2045 | 2.35 / 1304.87 | 2 | 2 |
5 | 7 | 1989.60 | 22 | 10.46 | 3079 | 709 | 3.06 / 1305.58 | 2 | 2 |
6 | 13 | 1251.16 | 45 | 12.42 | 2097 | 1172 | 4.23 / 1306.76 | 2 | 2 |
7 | 13 | 25.92 | 45 | 14.14 | 342 | 218 | 4.45 / 1306.97 | 2 | 2 |
8 | 8 | 0.12 | 180 | 14.17 | 305 | 778 | 5.23 / 1307.75 | 2 | 3 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 29 | 14.03 | 445 | 181 | 0.18 / 1299.14 | 2 | 2 |
2 | 3 | 932.04 | -1 | 14.03 | 445 | 0 | 0.00 / 1299.14 | 2 | 2 |
3 | 12 | 1110.68 | 75 | 7.51 | 1736 | 978 | 1.16 / 1300.12 | 2 | 2 |
4 | 7 | 1111.96 | 22 | 10.79 | 1850 | 439 | 1.60 / 1300.56 | 2 | 2 |
5 | 13 | 1019.88 | 45 | 11.97 | 1744 | 939 | 2.54 / 1301.50 | 2 | 2 |
6 | 13 | 57.88 | 45 | 14.06 | 387 | 245 | 2.78 / 1301.74 | 2 | 2 |
7 | 8 | -0.28 | 180 | 14.14 | 306 | 779 | 3.56 / 1302.52 | 2 | 8 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 27 | 14.04 | 465 | 176 | 0.18 / 1295.58 | 2 | 2 |
2 | 3 | 1027.44 | 1 | 12.12 | 1769 | 21 | 0.20 / 1295.60 | 2 | 2 |
3 | 12 | 1127.68 | 75 | 7.77 | 1775 | 1034 | 1.23 / 1296.64 | 2 | 2 |
4 | 7 | 1127.80 | 22 | 10.82 | 1876 | 447 | 1.68 / 1297.09 | 2 | 2 |
5 | 13 | 1020.12 | 45 | 12.12 | 1731 | 944 | 2.62 / 1298.03 | 2 | 2 |
6 | 13 | 12.52 | 45 | 14.15 | 300 | 191 | 2.81 / 1298.22 | 2 | 2 |
7 | 8 | 0.28 | 180 | 14.15 | 291 | 741 | 3.55 / 1298.96 | 2 | 6 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 30 | 14.07 | 454 | 192 | 0.19 / 1292.04 | 2 | 2 |
2 | 3 | 937.60 | -1 | 14.07 | 454 | 0 | 0.00 / 1292.04 | 2 | 2 |
3 | 12 | 1119.44 | 75 | 8.74 | 1799 | 1179 | 1.37 / 1293.22 | 2 | 2 |
4 | 7 | 1117.04 | 22 | 11.06 | 1882 | 458 | 1.83 / 1293.68 | 2 | 2 |
5 | 13 | 992.44 | 45 | 12.37 | 1713 | 954 | 2.78 / 1294.63 | 2 | 2 |
6 | 8 | 0.12 | 180 | 14.16 | 305 | 777 | 3.56 / 1295.41 | 2 | 2 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 29 | 14.04 | 452 | 184 | 0.18 / 1287.06 | 2 | 2 |
2 | 3 | 936.56 | -1 | 14.04 | 452 | 0 | 0.00 / 1287.06 | 2 | 2 |
3 | 12 | 1117.36 | 5 | 11.76 | 1886 | 111 | 0.29 / 1287.17 | 2 | 2 |
4 | 12 | 1996.40 | 75 | 9.19 | 3058 | 2108 | 2.40 / 1289.28 | 2 | 2 |
5 | 7 | 1989.32 | 22 | 10.50 | 3086 | 713 | 3.12 / 1289.99 | 2 | 2 |
6 | 13 | 1146.20 | 45 | 12.62 | 1947 | 1106 | 4.22 / 1291.10 | 2 | 2 |
7 | 8 | 0.20 | 180 | 14.20 | 293 | 749 | 4.97 / 1291.85 | 2 | 2 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 27 | 14.04 | 451 | 171 | 0.17 / 1283.43 | 2 | 2 |
2 | 3 | 1049.36 | 2 | 12.34 | 1819 | 45 | 0.22 / 1283.47 | 2 | 2 |
3 | 3 | 1015.36 | 1 | 11.76 | 1762 | 21 | 0.24 / 1283.49 | 2 | 2 |
4 | 12 | 1128.16 | 75 | 7.73 | 1763 | 1022 | 1.26 / 1284.52 | 2 | 2 |
5 | 7 | 1128.88 | 22 | 10.90 | 1878 | 450 | 1.71 / 1284.97 | 2 | 2 |
6 | 13 | 1031.16 | 45 | 12.14 | 1749 | 955 | 2.66 / 1285.92 | 2 | 2 |
7 | 13 | 11.76 | 45 | 14.15 | 296 | 188 | 2.85 / 1286.11 | 2 | 2 |
8 | 8 | -0.12 | 180 | 14.13 | 301 | 766 | 3.62 / 1286.88 | 2 | 5 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 25 | 14.05 | 468 | 164 | 0.16 / 1279.69 | 2 | 2 |
2 | 10 | 1029.16 | 4 | 12.83 | 1770 | 91 | 0.26 / 1279.78 | 2 | 2 |
3 | 3 | 1014.40 | 1 | 11.93 | 1770 | 21 | 0.28 / 1279.80 | 2 | 2 |
4 | 12 | 1142.40 | 75 | 7.97 | 1794 | 1072 | 1.35 / 1280.87 | 2 | 2 |
5 | 7 | 1142.12 | 22 | 10.97 | 1901 | 459 | 1.81 / 1281.33 | 2 | 2 |
6 | 13 | 1037.04 | 45 | 12.25 | 1750 | 965 | 2.77 / 1282.30 | 2 | 2 |
7 | 13 | 31.76 | 45 | 14.13 | 325 | 207 | 2.98 / 1282.50 | 2 | 2 |
8 | 8 | 0.08 | 180 | 14.15 | 296 | 754 | 3.73 / 1283.26 | 2 | 11 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 29 | 14.06 | 467 | 190 | 0.19 / 1275.88 | 2 | 2 |
2 | 3 | 919.20 | -1 | 14.06 | 467 | 0 | 0.00 / 1275.88 | 2 | 2 |
3 | 3 | 969.36 | -1 | 14.06 | 467 | 0 | 0.00 / 1275.88 | 2 | 2 |
4 | 12 | 1144.40 | 75 | 8.87 | 1830 | 1217 | 1.41 / 1277.09 | 2 | 2 |
5 | 7 | 1141.36 | 22 | 11.17 | 1894 | 465 | 1.87 / 1277.56 | 2 | 2 |
6 | 13 | 1008.32 | 45 | 12.43 | 1736 | 971 | 2.84 / 1278.53 | 2 | 2 |
7 | 13 | 33.96 | 45 | 14.11 | 350 | 222 | 3.07 / 1278.75 | 2 | 2 |
8 | 8 | -0.20 | 180 | 14.15 | 304 | 774 | 3.84 / 1279.53 | 2 | 4 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 28 | 14.02 | 464 | 182 | 0.18 / 1270.66 | 2 | 2 |
2 | 3 | 1021.28 | 1 | 12.04 | 1767 | 21 | 0.20 / 1270.68 | 2 | 2 |
3 | 12 | 1124.76 | 5 | 11.79 | 1897 | 112 | 0.32 / 1270.79 | 2 | 2 |
4 | 12 | 1995.80 | 75 | 9.34 | 3047 | 2134 | 2.45 / 1272.93 | 2 | 2 |
5 | 7 | 1988.20 | 22 | 10.61 | 3080 | 719 | 3.17 / 1273.65 | 2 | 2 |
6 | 13 | 1094.56 | 45 | 12.71 | 1869 | 1069 | 4.24 / 1274.71 | 2 | 2 |
7 | 13 | 14.08 | 45 | 14.17 | 318 | 203 | 4.44 / 1274.92 | 2 | 2 |
8 | 8 | -0.04 | 180 | 14.17 | 301 | 768 | 5.21 / 1275.68 | 2 | 5 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 28 | 14.06 | 458 | 180 | 0.18 / 1266.97 | 2 | 2 |
2 | 3 | 963.24 | -1 | 14.06 | 458 | 0 | 0.00 / 1266.97 | 2 | 2 |
3 | 3 | 1024.60 | 1 | 11.92 | 1780 | 21 | 0.20 / 1266.99 | 2 | 2 |
4 | 12 | 1130.88 | 75 | 7.65 | 1766 | 1013 | 1.21 / 1268.01 | 2 | 2 |
5 | 7 | 1132.20 | 22 | 11.03 | 1874 | 455 | 1.67 / 1268.46 | 2 | 2 |
6 | 13 | 1027.76 | 45 | 12.24 | 1741 | 959 | 2.63 / 1269.42 | 2 | 2 |
7 | 13 | 121.64 | 45 | 13.99 | 459 | 289 | 2.92 / 1269.71 | 2 | 2 |
8 | 8 | -0.04 | 180 | 14.14 | 301 | 766 | 3.68 / 1270.48 | 2 | 5 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 27 | 14.05 | 463 | 176 | 0.18 / 1263.29 | 2 | 2 |
2 | 3 | 1056.92 | 2 | 12.44 | 1830 | 46 | 0.22 / 1263.34 | 2 | 2 |
3 | 12 | 1138.28 | 75 | 8.05 | 1794 | 1083 | 1.30 / 1264.42 | 2 | 2 |
4 | 7 | 1137.88 | 22 | 11.07 | 1888 | 460 | 1.76 / 1264.88 | 2 | 2 |
5 | 13 | 1022.20 | 45 | 12.30 | 1739 | 963 | 2.73 / 1265.84 | 2 | 2 |
6 | 13 | 19.88 | 45 | 14.14 | 307 | 195 | 2.92 / 1266.04 | 2 | 2 |
7 | 8 | 0.12 | 180 | 14.12 | 298 | 757 | 3.68 / 1266.79 | 2 | 2 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 29 | 14.09 | 440 | 180 | 0.18 / 1259.53 | 2 | 2 |
2 | 3 | 921.72 | -1 | 14.09 | 440 | 0 | 0.00 / 1259.53 | 2 | 2 |
3 | 12 | 1106.80 | 75 | 9.01 | 1781 | 1204 | 1.38 / 1260.74 | 2 | 2 |
4 | 7 | 1104.60 | 22 | 11.29 | 1847 | 459 | 1.84 / 1261.20 | 2 | 2 |
5 | 13 | 983.68 | 45 | 12.52 | 1692 | 953 | 2.80 / 1262.15 | 2 | 2 |
6 | 13 | 5.60 | 45 | 14.15 | 308 | 196 | 2.99 / 1262.35 | 2 | 2 |
7 | 8 | -0.28 | 180 | 14.14 | 302 | 769 | 3.76 / 1263.11 | 2 | 6 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 27 | 14.03 | 444 | 168 | 0.17 / 1254.17 | 2 | 2 |
2 | 3 | 1022.00 | 1 | 12.01 | 1792 | 22 | 0.19 / 1254.20 | 2 | 2 |
3 | 12 | 1126.16 | 5 | 11.86 | 1894 | 112 | 0.30 / 1254.31 | 2 | 2 |
4 | 12 | 1996.24 | 75 | 9.41 | 3054 | 2155 | 2.46 / 1256.46 | 2 | 2 |
5 | 7 | 1988.68 | 22 | 10.63 | 3094 | 724 | 3.18 / 1257.19 | 2 | 2 |
6 | 13 | 1225.32 | 45 | 12.54 | 2061 | 1163 | 4.34 / 1258.35 | 2 | 2 |
7 | 13 | 53.52 | 45 | 14.12 | 375 | 238 | 4.58 / 1258.59 | 2 | 2 |
8 | 8 | 0.04 | 180 | 14.17 | 300 | 765 | 5.35 / 1259.35 | 2 | 4 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 28 | 14.05 | 451 | 177 | 0.18 / 1250.54 | 2 | 2 |
2 | 12 | 1126.60 | 75 | 7.82 | 1774 | 1040 | 1.22 / 1251.58 | 2 | 2 |
3 | 7 | 1126.88 | 22 | 11.11 | 1873 | 458 | 1.68 / 1252.03 | 2 | 2 |
4 | 13 | 1027.68 | 45 | 12.28 | 1756 | 970 | 2.65 / 1253.00 | 2 | 2 |
5 | 13 | 57.28 | 45 | 14.06 | 380 | 240 | 2.89 / 1253.25 | 2 | 2 |
6 | 8 | -0.04 | 180 | 14.14 | 299 | 761 | 3.65 / 1254.01 | 2 | 5 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 25 | 14.04 | 444 | 156 | 0.16 / 1246.78 | 2 | 2 |
2 | 10 | 1052.16 | 4 | 12.75 | 1815 | 93 | 0.25 / 1246.87 | 2 | 2 |
3 | 3 | 1015.68 | 1 | 11.93 | 1760 | 21 | 0.27 / 1246.90 | 2 | 2 |
4 | 12 | 1127.96 | 75 | 8.09 | 1776 | 1078 | 1.35 / 1247.97 | 2 | 2 |
5 | 7 | 1127.80 | 22 | 11.17 | 1874 | 461 | 1.81 / 1248.43 | 2 | 2 |
6 | 13 | 1024.36 | 45 | 12.38 | 1731 | 964 | 2.77 / 1249.40 | 2 | 2 |
7 | 13 | 44.88 | 45 | 14.11 | 339 | 215 | 2.99 / 1249.61 | 2 | 2 |
8 | 8 | -0.08 | 180 | 14.14 | 293 | 746 | 3.73 / 1250.36 | 2 | 4 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 31 | 14.08 | 438 | 191 | 0.19 / 1243.20 | 2 | 2 |
2 | 3 | 841.08 | -3 | 14.08 | 438 | 0 | 0.00 / 1243.20 | 2 | 2 |
3 | 12 | 1132.56 | 75 | 9.04 | 1819 | 1233 | 1.42 / 1244.43 | 2 | 2 |
4 | 7 | 1129.32 | 22 | 11.30 | 1877 | 467 | 1.89 / 1244.90 | 2 | 2 |
5 | 13 | 996.72 | 45 | 12.53 | 1716 | 968 | 2.86 / 1245.87 | 2 | 2 |
6 | 8 | 0.16 | 180 | 14.16 | 298 | 760 | 3.62 / 1246.63 | 2 | 2 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 28 | 14.07 | 440 | 173 | 0.17 / 1237.90 | 2 | 2 |
2 | 3 | 967.32 | -1 | 14.07 | 440 | 0 | 0.00 / 1237.90 | 2 | 2 |
3 | 3 | 1030.96 | 1 | 12.04 | 1776 | 21 | 0.19 / 1237.92 | 2 | 2 |
4 | 12 | 1122.32 | 5 | 11.85 | 1896 | 112 | 0.31 / 1238.03 | 2 | 2 |
5 | 12 | 1995.48 | 75 | 9.51 | 3057 | 2180 | 2.49 / 1240.21 | 2 | 2 |
6 | 7 | 1988.08 | 22 | 10.64 | 3098 | 725 | 3.21 / 1240.94 | 2 | 2 |
7 | 13 | 1120.00 | 45 | 12.70 | 1909 | 1091 | 4.30 / 1242.03 | 2 | 2 |
8 | 13 | 27.36 | 45 | 14.15 | 336 | 214 | 4.52 / 1242.24 | 2 | 2 |
9 | 8 | 0.00 | 180 | 14.17 | 301 | 768 | 5.29 / 1243.01 | 2 | 4 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 28 | 14.05 | 441 | 173 | 0.17 / 1234.27 | 2 | 2 |
2 | 12 | 1127.96 | 75 | 7.80 | 1771 | 1036 | 1.21 / 1235.31 | 2 | 2 |
3 | 7 | 1128.56 | 22 | 11.20 | 1877 | 462 | 1.67 / 1235.77 | 2 | 2 |
4 | 13 | 1031.04 | 45 | 12.37 | 1750 | 974 | 2.65 / 1236.75 | 2 | 2 |
5 | 13 | 67.16 | 45 | 14.06 | 377 | 239 | 2.88 / 1236.98 | 2 | 2 |
6 | 8 | -0.12 | 180 | 14.14 | 290 | 738 | 3.62 / 1237.72 | 2 | 5 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 27 | 14.06 | 453 | 172 | 0.17 / 1230.54 | 2 | 2 |
2 | 10 | 1004.00 | 4 | 12.88 | 1735 | 89 | 0.26 / 1230.63 | 2 | 2 |
3 | 12 | 1110.36 | 75 | 8.23 | 1759 | 1086 | 1.35 / 1231.72 | 2 | 2 |
4 | 7 | 1109.68 | 22 | 11.26 | 1856 | 460 | 1.81 / 1232.18 | 2 | 2 |
5 | 13 | 997.12 | 45 | 12.47 | 1701 | 955 | 2.76 / 1233.13 | 2 | 2 |
6 | 13 | 40.28 | 45 | 14.11 | 335 | 213 | 2.97 / 1233.34 | 2 | 2 |
7 | 8 | 0.08 | 180 | 14.14 | 297 | 756 | 3.73 / 1234.10 | 2 | 4 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 29 | 14.06 | 447 | 182 | 0.18 / 1226.90 | 2 | 2 |
2 | 3 | 969.12 | -1 | 14.06 | 447 | 0 | 0.00 / 1226.90 | 2 | 2 |
3 | 3 | 1026.12 | 1 | 12.36 | 1781 | 22 | 0.20 / 1226.92 | 2 | 2 |
4 | 12 | 1152.28 | 75 | 9.03 | 1843 | 1248 | 1.45 / 1228.17 | 2 | 2 |
5 | 7 | 1149.88 | 22 | 11.33 | 1913 | 477 | 1.93 / 1228.65 | 2 | 2 |
6 | 13 | 1023.56 | 45 | 12.55 | 1743 | 984 | 2.91 / 1229.63 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.16 | 289 | 737 | 3.65 / 1230.37 | 2 | 3 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 28 | 14.03 | 434 | 170 | 0.17 / 1221.60 | 2 | 2 |
2 | 12 | 1103.84 | 5 | 11.88 | 1859 | 110 | 0.28 / 1221.71 | 2 | 2 |
3 | 12 | 2011.36 | 75 | 9.57 | 3080 | 2211 | 2.49 / 1223.92 | 2 | 2 |
4 | 7 | 2004.36 | 22 | 10.68 | 3109 | 730 | 3.22 / 1224.65 | 2 | 2 |
5 | 13 | 1122.68 | 45 | 12.72 | 1908 | 1092 | 4.31 / 1225.74 | 2 | 2 |
6 | 13 | 25.60 | 45 | 14.15 | 332 | 211 | 4.53 / 1225.96 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.18 | 299 | 763 | 5.29 / 1226.72 | 2 | 5 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 29 | 14.05 | 440 | 179 | 0.18 / 1217.93 | 2 | 2 |
2 | 3 | 961.24 | -1 | 14.05 | 440 | 0 | 0.00 / 1217.93 | 2 | 2 |
3 | 3 | 1020.88 | 1 | 11.98 | 1774 | 21 | 0.20 / 1217.95 | 2 | 2 |
4 | 12 | 1151.04 | 75 | 7.78 | 1790 | 1044 | 1.24 / 1218.99 | 2 | 2 |
5 | 7 | 1151.88 | 22 | 11.24 | 1906 | 471 | 1.72 / 1219.47 | 2 | 2 |
6 | 13 | 1036.60 | 45 | 12.42 | 1759 | 983 | 2.70 / 1220.45 | 2 | 2 |
7 | 13 | 66.24 | 45 | 14.05 | 379 | 240 | 2.94 / 1220.69 | 2 | 2 |
8 | 8 | 0.12 | 180 | 14.12 | 292 | 742 | 3.68 / 1221.43 | 2 | 4 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 27 | 14.06 | 438 | 166 | 0.17 / 1214.26 | 2 | 2 |
2 | 3 | 1020.56 | 1 | 12.06 | 1781 | 21 | 0.19 / 1214.28 | 2 | 2 |
3 | 12 | 1128.80 | 75 | 8.21 | 1783 | 1098 | 1.29 / 1215.38 | 2 | 2 |
4 | 7 | 1127.52 | 22 | 11.29 | 1880 | 467 | 1.75 / 1215.85 | 2 | 2 |
5 | 13 | 1009.52 | 45 | 12.48 | 1719 | 965 | 2.72 / 1216.81 | 2 | 2 |
6 | 13 | 43.28 | 45 | 14.08 | 347 | 220 | 2.94 / 1217.03 | 2 | 2 |
7 | 8 | -0.04 | 180 | 14.14 | 281 | 715 | 3.65 / 1217.75 | 2 | 3 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 30 | 14.04 | 453 | 191 | 0.19 / 1210.68 | 2 | 2 |
2 | 3 | 943.44 | -1 | 14.04 | 453 | 0 | 0.00 / 1210.68 | 2 | 2 |
3 | 12 | 1135.48 | 75 | 9.27 | 1829 | 1272 | 1.46 / 1211.95 | 2 | 2 |
4 | 7 | 1131.88 | 22 | 11.43 | 1891 | 476 | 1.94 / 1212.43 | 2 | 2 |
5 | 13 | 874.72 | 45 | 12.89 | 1556 | 903 | 2.84 / 1213.33 | 2 | 2 |
6 | 8 | -0.16 | 180 | 14.13 | 302 | 768 | 3.61 / 1214.10 | 2 | 2 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 28 | 14.05 | 443 | 174 | 0.17 / 1205.36 | 2 | 2 |
2 | 12 | 1123.68 | 5 | 11.90 | 1911 | 114 | 0.29 / 1205.47 | 2 | 2 |
3 | 12 | 2000.76 | 75 | 9.60 | 3072 | 2212 | 2.50 / 1207.69 | 2 | 2 |
4 | 7 | 1993.44 | 22 | 10.73 | 3093 | 730 | 3.23 / 1208.42 | 2 | 2 |
5 | 13 | 1109.40 | 45 | 12.72 | 1895 | 1085 | 4.31 / 1209.50 | 2 | 2 |
6 | 13 | 26.88 | 45 | 14.14 | 339 | 216 | 4.53 / 1209.72 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.18 | 302 | 771 | 5.30 / 1210.49 | 2 | 4 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 29 | 14.05 | 443 | 181 | 0.18 / 1201.69 | 2 | 2 |
2 | 12 | 1097.76 | 75 | 8.35 | 1748 | 1095 | 1.28 / 1202.78 | 2 | 2 |
3 | 7 | 1097.44 | 22 | 11.37 | 1840 | 460 | 1.74 / 1203.24 | 2 | 2 |
4 | 13 | 990.44 | 45 | 12.49 | 1699 | 955 | 2.69 / 1204.20 | 2 | 2 |
5 | 13 | 37.08 | 45 | 14.07 | 350 | 222 | 2.91 / 1204.42 | 2 | 2 |
6 | 8 | 0.08 | 180 | 14.09 | 302 | 766 | 3.68 / 1205.19 | 2 | 6 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 28 | 14.07 | 451 | 178 | 0.18 / 1197.92 | 2 | 2 |
2 | 3 | 1041.00 | 1 | 12.42 | 1806 | 22 | 0.20 / 1197.94 | 2 | 2 |
3 | 3 | 1014.00 | 1 | 11.76 | 1783 | 21 | 0.22 / 1197.96 | 2 | 2 |
4 | 12 | 1138.24 | 75 | 8.41 | 1809 | 1141 | 1.36 / 1199.10 | 2 | 2 |
5 | 7 | 1137.00 | 22 | 11.35 | 1892 | 472 | 1.83 / 1199.58 | 2 | 2 |
6 | 13 | 1019.80 | 45 | 12.53 | 1736 | 979 | 2.81 / 1200.55 | 2 | 2 |
7 | 13 | 38.08 | 45 | 14.09 | 338 | 214 | 3.03 / 1200.77 | 2 | 2 |
8 | 8 | -0.44 | 180 | 14.12 | 291 | 740 | 3.77 / 1201.51 | 2 | 7 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 29 | 14.05 | 446 | 182 | 0.18 / 1194.30 | 2 | 2 |
2 | 3 | 957.72 | -1 | 14.05 | 446 | 0 | 0.00 / 1194.30 | 2 | 2 |
3 | 3 | 1017.52 | 1 | 12.22 | 1773 | 22 | 0.20 / 1194.32 | 2 | 2 |
4 | 12 | 1131.36 | 75 | 9.39 | 1826 | 1286 | 1.49 / 1195.61 | 2 | 2 |
5 | 7 | 1128.24 | 23 | 11.50 | 1887 | 499 | 1.99 / 1196.11 | 2 | 2 |
6 | 13 | 866.76 | 45 | 12.96 | 1534 | 895 | 2.88 / 1197.00 | 2 | 2 |
7 | 8 | 0.24 | 180 | 14.13 | 291 | 740 | 3.62 / 1197.74 | 2 | 2 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 29 | 14.04 | 440 | 179 | 0.18 / 1188.91 | 2 | 2 |
2 | 3 | 969.28 | -1 | 14.04 | 440 | 0 | 0.00 / 1188.91 | 2 | 2 |
3 | 3 | 1030.40 | 1 | 12.26 | 1786 | 22 | 0.20 / 1188.93 | 2 | 2 |
4 | 12 | 1121.76 | 5 | 11.93 | 1890 | 113 | 0.31 / 1189.05 | 2 | 2 |
5 | 12 | 1996.64 | 75 | 9.85 | 3061 | 2261 | 2.58 / 1191.31 | 2 | 2 |
6 | 7 | 1989.16 | 22 | 10.77 | 3082 | 730 | 3.31 / 1192.04 | 2 | 2 |
7 | 13 | 1091.40 | 45 | 12.77 | 1870 | 1075 | 4.38 / 1193.11 | 2 | 2 |
8 | 13 | 46.08 | 45 | 14.11 | 368 | 234 | 4.61 / 1193.34 | 2 | 2 |
9 | 8 | -0.04 | 180 | 14.18 | 303 | 773 | 5.39 / 1194.12 | 2 | 3 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 28 | 14.03 | 452 | 178 | 0.18 / 1185.18 | 2 | 2 |
2 | 3 | 1016.08 | 1 | 12.05 | 1785 | 22 | 0.20 / 1185.20 | 2 | 2 |
3 | 12 | 1133.08 | 75 | 8.20 | 1788 | 1100 | 1.30 / 1186.30 | 2 | 2 |
4 | 7 | 1132.64 | 22 | 11.37 | 1891 | 473 | 1.77 / 1186.77 | 2 | 2 |
5 | 13 | 1030.28 | 45 | 12.51 | 1742 | 981 | 2.75 / 1187.75 | 2 | 2 |
6 | 13 | 45.32 | 45 | 14.07 | 346 | 219 | 2.97 / 1187.97 | 2 | 2 |
7 | 8 | -0.28 | 180 | 14.10 | 299 | 759 | 3.73 / 1188.73 | 2 | 5 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 28 | 14.05 | 450 | 177 | 0.18 / 1181.44 | 2 | 2 |
2 | 3 | 1014.92 | 1 | 12.10 | 1767 | 21 | 0.20 / 1181.46 | 2 | 2 |
3 | 12 | 1126.96 | 75 | 8.65 | 1788 | 1160 | 1.36 / 1182.62 | 2 | 2 |
4 | 7 | 1125.20 | 22 | 11.45 | 1872 | 472 | 1.83 / 1183.09 | 2 | 2 |
5 | 13 | 1005.96 | 45 | 12.61 | 1712 | 971 | 2.80 / 1184.06 | 2 | 2 |
6 | 13 | 32.44 | 45 | 14.09 | 328 | 208 | 3.01 / 1184.27 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.11 | 288 | 731 | 3.74 / 1185.00 | 2 | 6 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 28 | 14.02 | 443 | 174 | 0.17 / 1177.93 | 2 | 2 |
2 | 12 | 1110.32 | 75 | 9.69 | 1805 | 1312 | 1.49 / 1179.24 | 2 | 2 |
3 | 7 | 1106.72 | 22 | 11.61 | 1850 | 473 | 1.96 / 1179.71 | 2 | 2 |
4 | 13 | 707.88 | 45 | 13.16 | 1326 | 785 | 2.74 / 1180.50 | 2 | 2 |
5 | 8 | 0.00 | 180 | 14.10 | 300 | 761 | 3.50 / 1181.26 | 2 | 3 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 27 | 14.00 | 459 | 174 | 0.17 / 1172.52 | 2 | 2 |
2 | 3 | 1044.20 | 2 | 12.57 | 1799 | 45 | 0.22 / 1172.57 | 2 | 2 |
3 | 12 | 1125.64 | 5 | 12.09 | 1895 | 115 | 0.33 / 1172.68 | 2 | 2 |
4 | 12 | 2004.52 | 75 | 9.87 | 3070 | 2273 | 2.61 / 1174.96 | 2 | 2 |
5 | 7 | 1996.88 | 22 | 10.76 | 3087 | 731 | 3.34 / 1175.69 | 2 | 2 |
6 | 13 | 1095.72 | 45 | 12.77 | 1866 | 1072 | 4.41 / 1176.76 | 2 | 2 |
7 | 13 | 42.92 | 45 | 14.11 | 360 | 229 | 4.64 / 1176.99 | 2 | 2 |
8 | 8 | -0.12 | 180 | 14.18 | 301 | 768 | 5.41 / 1177.76 | 2 | 7 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 28 | 14.00 | 453 | 178 | 0.18 / 1168.78 | 2 | 2 |
2 | 12 | 1127.04 | 75 | 8.55 | 1783 | 1143 | 1.32 / 1169.93 | 2 | 2 |
3 | 7 | 1126.48 | 22 | 11.44 | 1885 | 474 | 1.80 / 1170.40 | 2 | 2 |
4 | 13 | 1013.88 | 45 | 12.53 | 1743 | 983 | 2.78 / 1171.38 | 2 | 2 |
5 | 13 | 17.20 | 45 | 14.08 | 323 | 205 | 2.98 / 1171.59 | 2 | 2 |
6 | 8 | -0.04 | 180 | 14.08 | 300 | 760 | 3.74 / 1172.35 | 2 | 6 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 28 | 14.01 | 456 | 179 | 0.18 / 1165.18 | 2 | 2 |
2 | 12 | 1120.04 | 75 | 9.02 | 1798 | 1216 | 1.40 / 1166.40 | 2 | 2 |
3 | 7 | 1117.20 | 22 | 11.51 | 1865 | 472 | 1.87 / 1166.87 | 2 | 2 |
4 | 13 | 994.72 | 45 | 12.61 | 1710 | 970 | 2.84 / 1167.84 | 2 | 2 |
5 | 8 | 0.24 | 180 | 14.08 | 303 | 768 | 3.61 / 1168.61 | 2 | 2 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 28 | 14.02 | 444 | 174 | 0.17 / 1161.54 | 2 | 2 |
2 | 12 | 1111.88 | 75 | 9.85 | 1806 | 1334 | 1.51 / 1162.88 | 2 | 2 |
3 | 7 | 1108.48 | 22 | 11.62 | 1851 | 473 | 1.98 / 1163.35 | 2 | 2 |
4 | 13 | 837.08 | 45 | 12.98 | 1504 | 878 | 2.86 / 1164.23 | 2 | 2 |
5 | 8 | -0.04 | 180 | 14.08 | 304 | 770 | 3.63 / 1165.00 | 2 | 4 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 29 | 13.99 | 454 | 184 | 0.18 / 1156.41 | 2 | 2 |
2 | 3 | 953.88 | -1 | 13.99 | 454 | 0 | 0.00 / 1156.41 | 2 | 2 |
3 | 12 | 1120.80 | 5 | 12.08 | 1888 | 114 | 0.30 / 1156.53 | 2 | 2 |
4 | 12 | 1995.36 | 75 | 9.91 | 3058 | 2273 | 2.57 / 1158.80 | 2 | 2 |
5 | 7 | 1987.92 | 22 | 10.84 | 3086 | 736 | 3.31 / 1159.54 | 2 | 2 |
6 | 13 | 1068.44 | 45 | 12.81 | 1835 | 1058 | 4.36 / 1160.59 | 2 | 2 |
7 | 8 | 0.08 | 180 | 14.15 | 305 | 777 | 5.14 / 1161.37 | 2 | 2 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 27 | 14.00 | 449 | 170 | 0.17 / 1152.87 | 2 | 2 |
2 | 3 | 1026.72 | 1 | 12.47 | 1783 | 22 | 0.19 / 1152.89 | 2 | 2 |
3 | 12 | 1127.72 | 75 | 8.57 | 1781 | 1145 | 1.34 / 1154.04 | 2 | 2 |
4 | 7 | 1126.12 | 22 | 11.50 | 1871 | 473 | 1.81 / 1154.51 | 2 | 2 |
5 | 13 | 1006.20 | 45 | 12.62 | 1706 | 969 | 2.78 / 1155.48 | 2 | 2 |
6 | 8 | 0.00 | 180 | 14.07 | 295 | 747 | 3.53 / 1156.23 | 2 | 3 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 27 | 14.00 | 450 | 170 | 0.17 / 1149.25 | 2 | 2 |
2 | 3 | 1017.52 | 1 | 12.34 | 1768 | 22 | 0.19 / 1149.27 | 2 | 2 |
3 | 12 | 1132.92 | 75 | 9.06 | 1802 | 1224 | 1.42 / 1150.50 | 2 | 2 |
4 | 7 | 1130.00 | 22 | 11.56 | 1875 | 477 | 1.89 / 1150.98 | 2 | 2 |
5 | 13 | 1005.24 | 45 | 12.68 | 1707 | 974 | 2.87 / 1151.95 | 2 | 2 |
6 | 8 | -0.04 | 180 | 14.08 | 297 | 753 | 3.62 / 1152.70 | 2 | 3 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 27 | 14.01 | 448 | 169 | 0.17 / 1145.60 | 2 | 2 |
2 | 12 | 1119.52 | 75 | 9.91 | 1816 | 1350 | 1.52 / 1146.95 | 2 | 2 |
3 | 7 | 1115.68 | 22 | 11.66 | 1865 | 478 | 2.00 / 1147.43 | 2 | 2 |
4 | 13 | 842.76 | 45 | 13.03 | 1493 | 875 | 2.87 / 1148.30 | 2 | 2 |
5 | 8 | 0.04 | 180 | 14.09 | 308 | 781 | 3.65 / 1149.08 | 2 | 5 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 29 | 13.95 | 468 | 189 | 0.19 / 1140.23 | 2 | 2 |
2 | 12 | 1122.00 | 5 | 12.14 | 1887 | 115 | 0.30 / 1140.34 | 2 | 2 |
3 | 12 | 1997.20 | 75 | 10.00 | 3070 | 2302 | 2.61 / 1142.64 | 2 | 2 |
4 | 7 | 1989.76 | 22 | 10.86 | 3087 | 738 | 3.34 / 1143.38 | 2 | 2 |
5 | 13 | 1078.56 | 45 | 12.81 | 1847 | 1065 | 4.41 / 1144.44 | 2 | 2 |
6 | 13 | 5.32 | 45 | 14.20 | 312 | 199 | 4.61 / 1144.64 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.19 | 307 | 784 | 5.39 / 1145.43 | 2 | 5 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 29 | 14.00 | 452 | 184 | 0.18 / 1136.66 | 2 | 2 |
2 | 3 | 960.76 | -1 | 14.00 | 452 | 0 | 0.00 / 1136.66 | 2 | 2 |
3 | 12 | 1143.96 | 75 | 8.63 | 1795 | 1162 | 1.35 / 1137.82 | 2 | 2 |
4 | 7 | 1142.96 | 22 | 11.56 | 1902 | 484 | 1.83 / 1138.30 | 2 | 2 |
5 | 13 | 1026.84 | 45 | 12.64 | 1733 | 986 | 2.81 / 1139.29 | 2 | 2 |
6 | 8 | 0.08 | 180 | 14.10 | 295 | 749 | 3.56 / 1140.04 | 2 | 3 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 29 | 14.00 | 449 | 182 | 0.18 / 1132.98 | 2 | 2 |
2 | 3 | 961.32 | -1 | 14.00 | 449 | 0 | 0.00 / 1132.98 | 2 | 2 |
3 | 3 | 1021.20 | 1 | 12.33 | 1760 | 22 | 0.20 / 1133.00 | 2 | 2 |
4 | 12 | 1135.00 | 75 | 9.25 | 1804 | 1252 | 1.46 / 1134.26 | 2 | 2 |
5 | 7 | 1132.44 | 22 | 11.65 | 1880 | 482 | 1.94 / 1134.74 | 2 | 2 |
6 | 13 | 1003.20 | 45 | 12.71 | 1704 | 975 | 2.91 / 1135.71 | 2 | 2 |
7 | 8 | 0.12 | 180 | 14.08 | 300 | 760 | 3.67 / 1136.47 | 2 | 3 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 29 | 14.00 | 461 | 187 | 0.19 / 1129.39 | 2 | 2 |
2 | 12 | 1125.40 | 75 | 9.99 | 1827 | 1369 | 1.56 / 1130.76 | 2 | 2 |
3 | 7 | 1121.96 | 22 | 11.70 | 1883 | 485 | 2.04 / 1131.24 | 2 | 2 |
4 | 13 | 718.52 | 45 | 13.18 | 1339 | 794 | 2.83 / 1132.04 | 2 | 2 |
5 | 8 | 0.04 | 180 | 14.11 | 300 | 762 | 3.60 / 1132.80 | 2 | 3 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 28 | 13.96 | 455 | 178 | 0.18 / 1124.21 | 2 | 2 |
2 | 12 | 1125.88 | 5 | 12.14 | 1887 | 115 | 0.29 / 1124.33 | 2 | 2 |
3 | 12 | 1996.72 | 75 | 9.98 | 3067 | 2296 | 2.59 / 1126.62 | 2 | 2 |
4 | 7 | 1988.92 | 22 | 10.88 | 3093 | 740 | 3.33 / 1127.36 | 2 | 2 |
5 | 13 | 1080.04 | 45 | 12.80 | 1847 | 1064 | 4.39 / 1128.43 | 2 | 2 |
6 | 8 | 0.28 | 180 | 14.17 | 305 | 778 | 5.17 / 1129.20 | 2 | 3 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 26 | 13.99 | 444 | 162 | 0.16 / 1120.59 | 2 | 2 |
2 | 3 | 1079.88 | 3 | 12.82 | 1852 | 71 | 0.23 / 1120.66 | 2 | 2 |
3 | 12 | 1126.00 | 75 | 9.04 | 1787 | 1212 | 1.44 / 1121.87 | 2 | 2 |
4 | 7 | 1123.20 | 22 | 11.66 | 1866 | 479 | 1.92 / 1122.35 | 2 | 2 |
5 | 13 | 991.56 | 45 | 12.71 | 1687 | 965 | 2.89 / 1123.31 | 2 | 2 |
6 | 8 | -0.08 | 180 | 14.11 | 284 | 721 | 3.61 / 1124.03 | 2 | 4 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 28 | 13.96 | 466 | 182 | 0.18 / 1116.93 | 2 | 2 |
2 | 12 | 1135.72 | 75 | 9.42 | 1822 | 1287 | 1.47 / 1118.22 | 2 | 2 |
3 | 7 | 1132.08 | 22 | 11.67 | 1885 | 484 | 1.95 / 1118.70 | 2 | 2 |
4 | 13 | 997.88 | 45 | 12.75 | 1700 | 975 | 2.93 / 1119.68 | 2 | 2 |
5 | 8 | -0.36 | 180 | 14.11 | 294 | 747 | 3.68 / 1120.42 | 2 | 3 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 28 | 13.99 | 451 | 177 | 0.18 / 1113.34 | 2 | 2 |
2 | 12 | 1113.80 | 75 | 10.11 | 1820 | 1380 | 1.56 / 1114.72 | 2 | 2 |
3 | 7 | 1109.32 | 22 | 11.76 | 1857 | 480 | 2.04 / 1115.20 | 2 | 2 |
4 | 13 | 702.92 | 45 | 13.20 | 1317 | 782 | 2.82 / 1115.98 | 2 | 2 |
5 | 8 | 0.16 | 180 | 14.11 | 303 | 770 | 3.59 / 1116.75 | 2 | 4 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 27 | 13.95 | 450 | 169 | 0.17 / 1108.13 | 2 | 2 |
2 | 3 | 1031.28 | 1 | 12.61 | 1784 | 22 | 0.19 / 1108.15 | 2 | 2 |
3 | 12 | 1115.16 | 5 | 12.26 | 1882 | 115 | 0.31 / 1108.27 | 2 | 2 |
4 | 12 | 2002.52 | 75 | 10.05 | 3078 | 2320 | 2.63 / 1110.59 | 2 | 2 |
5 | 7 | 1994.92 | 22 | 10.87 | 3098 | 741 | 3.37 / 1111.33 | 2 | 2 |
6 | 13 | 1066.84 | 45 | 12.81 | 1831 | 1055 | 4.42 / 1112.38 | 2 | 2 |
7 | 8 | 0.20 | 180 | 14.17 | 304 | 775 | 5.20 / 1113.16 | 2 | 3 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 28 | 13.99 | 443 | 174 | 0.17 / 1104.50 | 2 | 2 |
2 | 3 | 943.16 | -1 | 13.99 | 443 | 0 | 0.00 / 1104.50 | 2 | 2 |
3 | 12 | 1129.28 | 75 | 9.17 | 1802 | 1239 | 1.41 / 1105.74 | 2 | 2 |
4 | 7 | 1126.60 | 22 | 11.67 | 1883 | 483 | 1.90 / 1106.22 | 2 | 2 |
5 | 13 | 995.12 | 45 | 12.72 | 1699 | 973 | 2.87 / 1107.19 | 2 | 2 |
6 | 8 | 0.00 | 180 | 14.09 | 302 | 766 | 3.63 / 1107.96 | 2 | 2 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 28 | 13.98 | 449 | 176 | 0.18 / 1100.70 | 2 | 2 |
2 | 12 | 1115.64 | 75 | 9.72 | 1800 | 1312 | 1.49 / 1102.01 | 2 | 2 |
3 | 7 | 1112.56 | 22 | 11.72 | 1859 | 479 | 1.97 / 1102.49 | 2 | 2 |
4 | 13 | 848.28 | 45 | 12.96 | 1511 | 881 | 2.85 / 1103.37 | 2 | 2 |
5 | 13 | 3.88 | 45 | 14.15 | 304 | 194 | 3.04 / 1103.56 | 2 | 2 |
6 | 8 | -0.04 | 180 | 14.11 | 301 | 764 | 3.81 / 1104.33 | 2 | 4 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 27 | 13.98 | 458 | 173 | 0.17 / 1097.20 | 2 | 2 |
2 | 3 | 1018.12 | 1 | 12.62 | 1774 | 22 | 0.20 / 1097.22 | 2 | 2 |
3 | 12 | 1135.72 | 75 | 10.06 | 1848 | 1394 | 1.59 / 1098.61 | 2 | 2 |
4 | 7 | 1131.20 | 22 | 11.76 | 1883 | 487 | 2.08 / 1099.10 | 2 | 2 |
5 | 13 | 587.44 | 45 | 13.37 | 1133 | 682 | 2.76 / 1099.78 | 2 | 2 |
6 | 8 | -0.12 | 180 | 14.15 | 289 | 736 | 3.49 / 1100.52 | 2 | 3 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 28 | 13.95 | 452 | 177 | 0.18 / 1092.01 | 2 | 2 |
2 | 3 | 966.44 | -1 | 13.95 | 452 | 0 | 0.00 / 1092.01 | 2 | 2 |
3 | 3 | 1024.00 | 1 | 12.40 | 1778 | 22 | 0.20 / 1092.03 | 2 | 2 |
4 | 12 | 1135.56 | 5 | 12.22 | 1920 | 117 | 0.32 / 1092.15 | 2 | 2 |
5 | 12 | 1996.48 | 75 | 10.04 | 3065 | 2308 | 2.62 / 1094.46 | 2 | 2 |
6 | 7 | 1988.60 | 22 | 10.91 | 3101 | 744 | 3.37 / 1095.20 | 2 | 2 |
7 | 13 | 1062.00 | 45 | 12.83 | 1821 | 1051 | 4.42 / 1096.25 | 2 | 2 |
8 | 8 | 0.04 | 180 | 14.19 | 303 | 774 | 5.19 / 1097.02 | 2 | 2 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 28 | 13.97 | 451 | 176 | 0.18 / 1088.43 | 2 | 2 |
2 | 12 | 1115.12 | 75 | 9.55 | 1796 | 1286 | 1.46 / 1089.71 | 2 | 2 |
3 | 7 | 1111.76 | 22 | 11.73 | 1862 | 481 | 1.94 / 1090.19 | 2 | 2 |
4 | 13 | 845.72 | 45 | 12.94 | 1508 | 878 | 2.82 / 1091.07 | 2 | 2 |
5 | 8 | 0.32 | 180 | 14.10 | 299 | 759 | 3.58 / 1091.83 | 2 | 3 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 29 | 14.00 | 450 | 183 | 0.18 / 1084.68 | 2 | 2 |
2 | 3 | 953.68 | -1 | 14.00 | 450 | 0 | 0.00 / 1084.68 | 2 | 2 |
3 | 3 | 1016.64 | 1 | 12.41 | 1776 | 22 | 0.20 / 1084.71 | 2 | 2 |
4 | 12 | 1135.24 | 75 | 9.70 | 1826 | 1328 | 1.53 / 1086.03 | 2 | 2 |
5 | 7 | 1132.28 | 22 | 11.76 | 1888 | 488 | 2.02 / 1086.52 | 2 | 2 |
6 | 13 | 997.92 | 45 | 12.80 | 1706 | 983 | 3.00 / 1087.51 | 2 | 2 |
7 | 8 | -0.04 | 180 | 14.13 | 293 | 745 | 3.75 / 1088.25 | 2 | 7 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 29 | 14.02 | 459 | 187 | 0.19 / 1081.17 | 2 | 2 |
2 | 12 | 1112.64 | 75 | 10.24 | 1832 | 1407 | 1.59 / 1082.58 | 2 | 2 |
3 | 7 | 1108.16 | 22 | 11.85 | 1851 | 483 | 2.08 / 1083.06 | 2 | 2 |
4 | 13 | 562.00 | 45 | 13.39 | 1118 | 674 | 2.75 / 1083.73 | 2 | 2 |
5 | 8 | -0.12 | 180 | 14.12 | 303 | 770 | 3.52 / 1084.50 | 2 | 3 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 28 | 13.99 | 446 | 175 | 0.17 / 1075.96 | 2 | 2 |
2 | 12 | 1101.48 | 5 | 12.33 | 1860 | 115 | 0.29 / 1076.07 | 2 | 2 |
3 | 12 | 1995.12 | 75 | 10.11 | 3068 | 2326 | 2.62 / 1078.40 | 2 | 2 |
4 | 7 | 1986.96 | 22 | 10.96 | 3086 | 744 | 3.36 / 1079.14 | 2 | 2 |
5 | 13 | 1066.44 | 45 | 12.82 | 1835 | 1059 | 4.42 / 1080.20 | 2 | 2 |
6 | 8 | 0.20 | 180 | 14.19 | 305 | 779 | 5.20 / 1080.98 | 2 | 4 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 27 | 13.99 | 447 | 169 | 0.17 / 1072.33 | 2 | 2 |
2 | 3 | 1044.00 | 2 | 12.69 | 1805 | 46 | 0.21 / 1072.37 | 2 | 2 |
3 | 12 | 1130.76 | 75 | 9.54 | 1818 | 1301 | 1.52 / 1073.67 | 2 | 2 |
4 | 7 | 1127.64 | 22 | 11.76 | 1877 | 486 | 2.00 / 1074.16 | 2 | 2 |
5 | 13 | 852.80 | 45 | 12.97 | 1511 | 882 | 2.88 / 1075.04 | 2 | 2 |
6 | 8 | 0.20 | 180 | 14.12 | 293 | 745 | 3.63 / 1075.78 | 2 | 3 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 28 | 13.96 | 474 | 185 | 0.19 / 1068.67 | 2 | 2 |
2 | 12 | 1125.12 | 75 | 9.90 | 1823 | 1354 | 1.54 / 1070.03 | 2 | 2 |
3 | 7 | 1121.20 | 22 | 11.81 | 1875 | 487 | 2.03 / 1070.51 | 2 | 2 |
4 | 13 | 845.48 | 45 | 13.03 | 1499 | 879 | 2.90 / 1071.39 | 2 | 2 |
5 | 8 | 0.08 | 180 | 14.13 | 301 | 766 | 3.67 / 1072.16 | 2 | 2 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 28 | 14.02 | 449 | 176 | 0.18 / 1065.05 | 2 | 2 |
2 | 12 | 1112.60 | 75 | 10.27 | 1831 | 1410 | 1.59 / 1066.46 | 2 | 2 |
3 | 7 | 1108.04 | 22 | 11.91 | 1859 | 487 | 2.07 / 1066.94 | 2 | 2 |
4 | 13 | 680.20 | 45 | 13.25 | 1288 | 768 | 2.84 / 1067.71 | 2 | 2 |
5 | 8 | 0.16 | 180 | 14.14 | 304 | 774 | 3.62 / 1068.49 | 2 | 3 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 28 | 13.98 | 459 | 180 | 0.18 / 1059.92 | 2 | 2 |
2 | 12 | 1107.72 | 5 | 12.39 | 1874 | 116 | 0.30 / 1060.04 | 2 | 2 |
3 | 12 | 1997.36 | 75 | 10.22 | 3079 | 2360 | 2.66 / 1062.40 | 2 | 2 |
4 | 7 | 1989.96 | 22 | 10.99 | 3091 | 747 | 3.40 / 1063.15 | 2 | 2 |
5 | 13 | 920.64 | 45 | 13.01 | 1621 | 949 | 4.35 / 1064.09 | 2 | 2 |
6 | 8 | 0.12 | 180 | 14.19 | 304 | 776 | 5.13 / 1064.87 | 2 | 3 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 28 | 13.98 | 450 | 176 | 0.18 / 1056.24 | 2 | 2 |
2 | 3 | 963.88 | -1 | 13.98 | 450 | 0 | 0.00 / 1056.24 | 2 | 2 |
3 | 3 | 1015.80 | 1 | 12.25 | 1775 | 22 | 0.20 / 1056.26 | 2 | 2 |
4 | 12 | 1142.84 | 75 | 9.54 | 1832 | 1311 | 1.51 / 1057.57 | 2 | 2 |
5 | 7 | 1140.24 | 22 | 11.79 | 1901 | 493 | 2.00 / 1058.07 | 2 | 2 |
6 | 13 | 883.60 | 45 | 12.97 | 1551 | 905 | 2.91 / 1058.97 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.13 | 303 | 771 | 3.68 / 1059.74 | 2 | 3 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 28 | 13.98 | 458 | 179 | 0.18 / 1052.37 | 2 | 2 |
2 | 12 | 1104.08 | 75 | 10.06 | 1804 | 1361 | 1.54 / 1053.73 | 2 | 2 |
3 | 7 | 1099.44 | 22 | 11.87 | 1871 | 489 | 2.03 / 1054.22 | 2 | 2 |
4 | 13 | 815.44 | 45 | 13.06 | 1480 | 870 | 2.90 / 1055.09 | 2 | 2 |
5 | 13 | 18.72 | 45 | 14.14 | 326 | 207 | 3.11 / 1055.30 | 2 | 2 |
6 | 8 | -0.04 | 180 | 14.13 | 301 | 766 | 3.87 / 1056.06 | 2 | 5 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 28 | 13.98 | 458 | 179 | 0.18 / 1048.79 | 2 | 2 |
2 | 12 | 1129.44 | 75 | 10.31 | 1841 | 1424 | 1.60 / 1050.22 | 2 | 2 |
3 | 7 | 1125.36 | 22 | 11.86 | 1901 | 496 | 2.10 / 1050.71 | 2 | 2 |
4 | 13 | 586.80 | 45 | 13.36 | 1160 | 697 | 2.80 / 1051.41 | 2 | 2 |
5 | 8 | 0.12 | 180 | 14.14 | 307 | 781 | 3.58 / 1052.19 | 2 | 3 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 28 | 13.98 | 449 | 176 | 0.18 / 1043.94 | 2 | 2 |
2 | 3 | 1018.68 | 1 | 12.59 | 1767 | 22 | 0.20 / 1043.97 | 2 | 2 |
3 | 12 | 1131.52 | 5 | 12.40 | 1907 | 118 | 0.32 / 1044.08 | 2 | 2 |
4 | 12 | 1795.44 | 75 | 10.53 | 2817 | 2225 | 2.54 / 1046.31 | 2 | 2 |
5 | 7 | 1790.60 | 22 | 11.12 | 2829 | 692 | 3.23 / 1047.00 | 2 | 2 |
6 | 13 | 769.04 | 45 | 13.16 | 1415 | 838 | 4.07 / 1047.84 | 2 | 2 |
7 | 8 | 0.12 | 180 | 14.17 | 304 | 775 | 4.85 / 1048.62 | 2 | 2 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 28 | 14.00 | 446 | 175 | 0.17 / 1040.27 | 2 | 2 |
2 | 12 | 1109.88 | 75 | 10.08 | 1806 | 1365 | 1.54 / 1041.64 | 2 | 2 |
3 | 7 | 1105.44 | 22 | 11.83 | 1877 | 489 | 2.03 / 1042.13 | 2 | 2 |
4 | 13 | 826.80 | 45 | 13.01 | 1495 | 875 | 2.90 / 1043.00 | 2 | 2 |
5 | 8 | -0.12 | 180 | 14.13 | 302 | 768 | 3.67 / 1043.77 | 2 | 4 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 28 | 14.03 | 442 | 174 | 0.17 / 1036.77 | 2 | 2 |
2 | 12 | 1125.96 | 75 | 10.10 | 1832 | 1388 | 1.56 / 1038.16 | 2 | 2 |
3 | 7 | 1121.64 | 22 | 11.86 | 1873 | 489 | 2.05 / 1038.64 | 2 | 2 |
4 | 13 | 574.20 | 45 | 13.36 | 1137 | 684 | 2.73 / 1039.33 | 2 | 2 |
5 | 8 | -0.04 | 180 | 14.14 | 302 | 769 | 3.50 / 1040.10 | 2 | 3 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 28 | 14.03 | 451 | 177 | 0.18 / 1033.10 | 2 | 2 |
2 | 12 | 1138.68 | 75 | 10.38 | 1859 | 1447 | 1.62 / 1034.55 | 2 | 2 |
3 | 7 | 1134.20 | 22 | 11.85 | 1920 | 501 | 2.12 / 1035.05 | 2 | 2 |
4 | 13 | 697.60 | 45 | 13.23 | 1311 | 781 | 2.91 / 1035.83 | 2 | 2 |
5 | 8 | -0.12 | 180 | 14.16 | 301 | 767 | 3.67 / 1036.59 | 2 | 3 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 29 | 14.00 | 449 | 182 | 0.18 / 1027.84 | 2 | 2 |
2 | 3 | 964.56 | -1 | 14.00 | 449 | 0 | 0.00 / 1027.84 | 2 | 2 |
3 | 3 | 1024.04 | 1 | 12.48 | 1763 | 22 | 0.20 / 1027.86 | 2 | 2 |
4 | 12 | 1119.84 | 5 | 12.44 | 1896 | 118 | 0.32 / 1027.98 | 2 | 2 |
5 | 12 | 1995.92 | 75 | 10.33 | 3070 | 2378 | 2.70 / 1030.35 | 2 | 2 |
6 | 7 | 1987.64 | 22 | 10.99 | 3088 | 747 | 3.45 / 1031.10 | 2 | 2 |
7 | 13 | 1054.00 | 45 | 12.84 | 1812 | 1047 | 4.49 / 1032.15 | 2 | 2 |
8 | 8 | 0.08 | 180 | 14.20 | 303 | 774 | 5.27 / 1032.92 | 2 | 3 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 28 | 14.03 | 448 | 176 | 0.18 / 1024.15 | 2 | 2 |
2 | 12 | 1123.52 | 75 | 10.04 | 1823 | 1373 | 1.55 / 1025.52 | 2 | 2 |
3 | 7 | 1119.64 | 22 | 11.83 | 1870 | 487 | 2.04 / 1026.01 | 2 | 2 |
4 | 13 | 840.00 | 45 | 13.01 | 1500 | 878 | 2.91 / 1026.89 | 2 | 2 |
5 | 8 | 0.08 | 180 | 14.14 | 300 | 764 | 3.68 / 1027.65 | 2 | 4 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 27 | 14.02 | 446 | 169 | 0.17 / 1020.51 | 2 | 2 |
2 | 3 | 1036.56 | 1 | 12.82 | 1790 | 23 | 0.19 / 1020.53 | 2 | 2 |
3 | 12 | 1136.60 | 75 | 10.10 | 1849 | 1401 | 1.59 / 1021.93 | 2 | 2 |
4 | 7 | 1132.80 | 22 | 11.85 | 1893 | 494 | 2.09 / 1022.43 | 2 | 2 |
5 | 13 | 725.68 | 45 | 13.19 | 1332 | 791 | 2.88 / 1023.22 | 2 | 2 |
6 | 8 | 0.04 | 180 | 14.16 | 297 | 757 | 3.63 / 1023.98 | 2 | 3 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 29 | 14.07 | 443 | 181 | 0.18 / 1017.00 | 2 | 2 |
2 | 3 | 950.56 | -1 | 14.07 | 443 | 0 | 0.00 / 1017.00 | 2 | 2 |
3 | 12 | 1119.52 | 75 | 10.43 | 1836 | 1436 | 1.62 / 1018.44 | 2 | 2 |
4 | 7 | 1115.00 | 22 | 11.93 | 1869 | 491 | 2.11 / 1018.93 | 2 | 2 |
5 | 13 | 558.52 | 45 | 13.41 | 1096 | 661 | 2.77 / 1019.59 | 2 | 2 |
6 | 8 | -0.16 | 180 | 14.16 | 295 | 752 | 3.52 / 1020.34 | 2 | 3 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 29 | 14.02 | 449 | 183 | 0.18 / 1011.54 | 2 | 2 |
2 | 12 | 1104.84 | 5 | 12.41 | 1873 | 116 | 0.30 / 1011.65 | 2 | 2 |
3 | 12 | 1997.92 | 75 | 10.26 | 3088 | 2376 | 2.67 / 1014.03 | 2 | 2 |
4 | 7 | 1990.20 | 22 | 11.01 | 3104 | 752 | 3.43 / 1014.78 | 2 | 2 |
5 | 13 | 1057.60 | 45 | 12.83 | 1825 | 1054 | 4.48 / 1015.84 | 2 | 2 |
6 | 13 | 1.52 | 45 | 14.25 | 309 | 198 | 4.68 / 1016.03 | 2 | 2 |
7 | 8 | -0.04 | 180 | 14.16 | 309 | 788 | 5.47 / 1016.82 | 2 | 7 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 28 | 14.04 | 444 | 175 | 0.17 / 1007.96 | 2 | 2 |
2 | 12 | 1114.56 | 75 | 10.09 | 1817 | 1375 | 1.55 / 1009.33 | 2 | 2 |
3 | 7 | 1110.04 | 22 | 11.87 | 1854 | 484 | 2.03 / 1009.82 | 2 | 2 |
4 | 13 | 695.68 | 45 | 13.18 | 1304 | 773 | 2.81 / 1010.59 | 2 | 2 |
5 | 8 | -0.16 | 180 | 14.13 | 301 | 766 | 3.57 / 1011.36 | 2 | 5 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 27 | 14.04 | 440 | 167 | 0.17 / 1004.29 | 2 | 2 |
2 | 3 | 1048.56 | 2 | 12.85 | 1815 | 47 | 0.21 / 1004.34 | 2 | 2 |
3 | 12 | 1140.28 | 75 | 10.13 | 1851 | 1406 | 1.62 / 1005.74 | 2 | 2 |
4 | 7 | 1135.88 | 22 | 11.86 | 1894 | 494 | 2.11 / 1006.24 | 2 | 2 |
5 | 13 | 715.40 | 45 | 13.20 | 1317 | 782 | 2.90 / 1007.02 | 2 | 2 |
6 | 8 | 0.20 | 180 | 14.16 | 299 | 762 | 3.66 / 1007.78 | 2 | 4 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 29 | 14.06 | 446 | 182 | 0.18 / 1000.64 | 2 | 2 |
2 | 3 | 948.12 | -1 | 14.06 | 446 | 0 | 0.00 / 1000.64 | 2 | 2 |
3 | 12 | 1136.48 | 75 | 10.42 | 1855 | 1450 | 1.63 / 1002.09 | 2 | 2 |
4 | 7 | 1132.20 | 22 | 11.93 | 1885 | 495 | 2.13 / 1002.59 | 2 | 2 |
5 | 13 | 704.08 | 45 | 13.24 | 1299 | 774 | 2.90 / 1003.36 | 2 | 2 |
6 | 8 | -0.16 | 180 | 14.16 | 300 | 765 | 3.66 / 1004.12 | 2 | 3 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 27 | 14.02 | 445 | 168 | 0.17 / 995.00 | 2 | 2 |
2 | 3 | 1043.68 | 2 | 12.76 | 1801 | 46 | 0.21 / 995.05 | 2 | 2 |
3 | 3 | 1015.96 | 1 | 12.19 | 1780 | 22 | 0.24 / 995.07 | 2 | 2 |
4 | 12 | 1118.28 | 5 | 12.44 | 1905 | 118 | 0.35 / 995.19 | 2 | 2 |
5 | 12 | 1997.28 | 75 | 10.35 | 3074 | 2386 | 2.74 / 997.57 | 2 | 2 |
6 | 7 | 1989.52 | 22 | 11.05 | 3097 | 753 | 3.49 / 998.32 | 2 | 2 |
7 | 13 | 1181.44 | 45 | 12.67 | 1999 | 1140 | 4.63 / 999.46 | 2 | 2 |
8 | 13 | 22.56 | 45 | 14.18 | 336 | 214 | 4.85 / 999.68 | 2 | 2 |
9 | 8 | 0.00 | 180 | 14.18 | 306 | 781 | 5.63 / 1000.46 | 2 | 5 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 28 | 14.04 | 438 | 172 | 0.17 / 991.29 | 2 | 2 |
2 | 12 | 1134.32 | 75 | 10.09 | 1848 | 1398 | 1.57 / 992.68 | 2 | 2 |
3 | 7 | 1129.84 | 22 | 11.83 | 1889 | 492 | 2.06 / 993.18 | 2 | 2 |
4 | 13 | 845.12 | 45 | 12.98 | 1517 | 886 | 2.95 / 994.06 | 2 | 2 |
5 | 8 | 0.04 | 180 | 14.13 | 302 | 768 | 3.72 / 994.83 | 2 | 3 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 27 | 14.05 | 444 | 168 | 0.17 / 987.72 | 2 | 2 |
2 | 3 | 1037.40 | 1 | 12.78 | 1798 | 23 | 0.19 / 987.75 | 2 | 2 |
3 | 12 | 1137.16 | 65 | 10.18 | 1858 | 1229 | 1.42 / 988.98 | 2 | 2 |
4 | 7 | 1134.24 | 22 | 11.93 | 1900 | 499 | 1.92 / 989.47 | 2 | 2 |
5 | 13 | 863.96 | 45 | 13.00 | 1526 | 893 | 2.81 / 990.37 | 2 | 2 |
6 | 8 | -0.04 | 180 | 14.16 | 293 | 747 | 3.56 / 991.11 | 2 | 3 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 29 | 14.06 | 447 | 182 | 0.18 / 984.03 | 2 | 2 |
2 | 3 | 945.80 | -1 | 14.06 | 447 | 0 | 0.00 / 984.03 | 2 | 2 |
3 | 12 | 1119.56 | 65 | 10.59 | 1841 | 1267 | 1.45 / 985.30 | 2 | 2 |
4 | 7 | 1115.88 | 22 | 12.01 | 1882 | 497 | 1.95 / 985.80 | 2 | 2 |
5 | 13 | 982.44 | 45 | 12.86 | 1707 | 988 | 2.93 / 986.79 | 2 | 2 |
6 | 8 | -0.04 | 180 | 14.15 | 302 | 769 | 3.70 / 987.56 | 2 | 5 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 28 | 14.02 | 447 | 175 | 0.18 / 978.69 | 2 | 2 |
2 | 3 | 965.32 | -1 | 14.02 | 447 | 0 | 0.00 / 978.69 | 2 | 2 |
3 | 3 | 1022.40 | 1 | 12.49 | 1789 | 22 | 0.20 / 978.71 | 2 | 2 |
4 | 12 | 1129.20 | 5 | 12.48 | 1908 | 119 | 0.32 / 978.83 | 2 | 2 |
5 | 12 | 1996.92 | 65 | 10.43 | 3088 | 2094 | 2.41 / 980.93 | 2 | 2 |
6 | 7 | 1989.88 | 22 | 11.09 | 3103 | 757 | 3.17 / 981.68 | 2 | 2 |
7 | 13 | 1233.00 | 45 | 12.61 | 2079 | 1180 | 4.35 / 982.86 | 2 | 2 |
8 | 13 | 20.76 | 45 | 14.19 | 332 | 212 | 4.56 / 983.08 | 2 | 2 |
9 | 8 | -0.36 | 180 | 14.17 | 304 | 775 | 5.33 / 983.85 | 2 | 5 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 28 | 14.02 | 453 | 178 | 0.18 / 974.86 | 2 | 2 |
2 | 12 | 1118.32 | 65 | 10.21 | 1837 | 1219 | 1.40 / 976.08 | 2 | 2 |
3 | 7 | 1114.44 | 22 | 11.94 | 1872 | 492 | 1.89 / 976.57 | 2 | 2 |
4 | 13 | 979.68 | 45 | 12.79 | 1699 | 978 | 2.87 / 977.55 | 2 | 2 |
5 | 13 | 3.60 | 45 | 14.17 | 309 | 197 | 3.06 / 977.75 | 2 | 3 |
6 | 8 | 0.16 | 180 | 14.12 | 303 | 770 | 3.83 / 978.52 | 2 | 3 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 27 | 14.05 | 451 | 171 | 0.17 / 971.03 | 2 | 2 |
2 | 3 | 1050.20 | 2 | 12.82 | 1821 | 47 | 0.22 / 971.07 | 2 | 2 |
3 | 12 | 1128.16 | 65 | 10.32 | 1857 | 1246 | 1.46 / 972.32 | 2 | 2 |
4 | 7 | 1125.52 | 22 | 11.95 | 1887 | 496 | 1.96 / 972.81 | 2 | 2 |
5 | 13 | 856.96 | 45 | 13.01 | 1521 | 890 | 2.85 / 973.70 | 2 | 2 |
6 | 13 | 19.72 | 45 | 14.15 | 324 | 206 | 3.06 / 973.91 | 2 | 2 |
7 | 8 | -0.24 | 180 | 14.12 | 304 | 773 | 3.83 / 974.68 | 2 | 7 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 27 | 14.07 | 442 | 168 | 0.17 / 967.42 | 2 | 2 |
2 | 12 | 1126.00 | 65 | 10.60 | 1853 | 1277 | 1.44 / 968.69 | 2 | 2 |
3 | 7 | 1122.56 | 22 | 12.03 | 1882 | 498 | 1.94 / 969.19 | 2 | 2 |
4 | 13 | 848.84 | 45 | 13.04 | 1520 | 892 | 2.83 / 970.08 | 2 | 2 |
5 | 8 | 0.12 | 180 | 14.16 | 303 | 772 | 3.61 / 970.85 | 2 | 3 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 28 | 14.03 | 447 | 176 | 0.18 / 962.11 | 2 | 2 |
2 | 12 | 1113.16 | 5 | 12.44 | 1899 | 118 | 0.29 / 962.23 | 2 | 2 |
3 | 12 | 1996.76 | 65 | 10.48 | 3087 | 2103 | 2.40 / 964.33 | 2 | 2 |
4 | 7 | 1989.28 | 22 | 11.13 | 3085 | 755 | 3.15 / 965.08 | 2 | 2 |
5 | 13 | 1212.28 | 45 | 12.64 | 2048 | 1165 | 4.32 / 966.25 | 2 | 2 |
6 | 13 | 35.64 | 45 | 14.15 | 352 | 224 | 4.54 / 966.47 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.18 | 303 | 773 | 5.31 / 967.25 | 2 | 5 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 28 | 14.01 | 448 | 176 | 0.18 / 958.54 | 2 | 2 |
2 | 12 | 1117.80 | 65 | 10.33 | 1846 | 1239 | 1.42 / 959.78 | 2 | 2 |
3 | 7 | 1114.36 | 22 | 11.95 | 1870 | 492 | 1.91 / 960.27 | 2 | 2 |
4 | 13 | 856.72 | 45 | 12.97 | 1532 | 894 | 2.80 / 961.16 | 2 | 2 |
5 | 8 | -0.32 | 180 | 14.13 | 303 | 771 | 3.57 / 961.93 | 2 | 2 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 27 | 14.02 | 448 | 170 | 0.17 / 954.95 | 2 | 2 |
2 | 12 | 1124.48 | 65 | 10.32 | 1852 | 1242 | 1.41 / 956.19 | 2 | 2 |
3 | 7 | 1121.64 | 22 | 11.99 | 1890 | 499 | 1.91 / 956.69 | 2 | 2 |
4 | 13 | 861.44 | 45 | 13.01 | 1529 | 895 | 2.81 / 957.59 | 2 | 2 |
5 | 8 | 0.04 | 180 | 14.14 | 304 | 774 | 3.58 / 958.36 | 2 | 3 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 27 | 14.05 | 445 | 169 | 0.17 / 951.43 | 2 | 2 |
2 | 12 | 1124.96 | 65 | 10.62 | 1858 | 1283 | 1.45 / 952.72 | 2 | 2 |
3 | 7 | 1121.24 | 22 | 12.05 | 1878 | 498 | 1.95 / 953.21 | 2 | 2 |
4 | 13 | 712.12 | 45 | 13.20 | 1335 | 793 | 2.74 / 954.01 | 2 | 2 |
5 | 8 | 0.00 | 180 | 14.14 | 304 | 774 | 3.52 / 954.78 | 2 | 2 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 28 | 14.01 | 454 | 178 | 0.18 / 946.19 | 2 | 2 |
2 | 12 | 1124.96 | 5 | 12.46 | 1921 | 120 | 0.30 / 946.31 | 2 | 2 |
3 | 12 | 2002.00 | 65 | 10.56 | 3087 | 2119 | 2.42 / 948.43 | 2 | 2 |
4 | 7 | 1994.96 | 22 | 11.14 | 3106 | 761 | 3.18 / 949.19 | 2 | 2 |
5 | 13 | 1100.12 | 45 | 12.78 | 1889 | 1086 | 4.26 / 950.27 | 2 | 2 |
6 | 13 | 19.52 | 45 | 14.18 | 331 | 211 | 4.48 / 950.48 | 2 | 2 |
7 | 8 | 0.04 | 180 | 14.15 | 307 | 782 | 5.26 / 951.27 | 2 | 5 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 28 | 13.98 | 466 | 182 | 0.18 / 942.54 | 2 | 2 |
2 | 12 | 1127.68 | 65 | 10.27 | 1856 | 1239 | 1.42 / 943.78 | 2 | 2 |
3 | 7 | 1124.88 | 22 | 11.96 | 1889 | 497 | 1.92 / 944.28 | 2 | 2 |
4 | 13 | 995.48 | 45 | 12.80 | 1708 | 984 | 2.90 / 945.26 | 2 | 2 |
5 | 8 | -0.08 | 180 | 14.14 | 294 | 748 | 3.65 / 946.01 | 2 | 3 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 27 | 14.01 | 445 | 168 | 0.17 / 938.85 | 2 | 2 |
2 | 12 | 1135.56 | 65 | 10.38 | 1865 | 1258 | 1.43 / 940.11 | 2 | 2 |
3 | 7 | 1132.72 | 22 | 11.97 | 1900 | 500 | 1.93 / 940.61 | 2 | 2 |
4 | 13 | 998.80 | 45 | 12.84 | 1712 | 989 | 2.92 / 941.60 | 2 | 2 |
5 | 8 | 0.00 | 180 | 14.14 | 298 | 758 | 3.67 / 942.36 | 2 | 4 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 29 | 14.04 | 462 | 188 | 0.19 / 935.31 | 2 | 2 |
2 | 3 | 953.68 | -1 | 14.04 | 462 | 0 | 0.00 / 935.31 | 2 | 2 |
3 | 12 | 1132.92 | 65 | 10.63 | 1874 | 1295 | 1.48 / 936.60 | 2 | 2 |
4 | 7 | 1128.56 | 22 | 12.06 | 1886 | 500 | 1.98 / 937.10 | 2 | 2 |
5 | 13 | 732.04 | 45 | 13.20 | 1346 | 800 | 2.78 / 937.90 | 2 | 2 |
6 | 8 | -0.12 | 180 | 14.12 | 308 | 783 | 3.57 / 938.68 | 2 | 3 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 28 | 13.99 | 466 | 183 | 0.18 / 930.11 | 2 | 2 |
2 | 12 | 1127.40 | 5 | 12.53 | 1922 | 120 | 0.30 / 930.23 | 2 | 2 |
3 | 12 | 1999.24 | 65 | 10.59 | 3096 | 2131 | 2.43 / 932.36 | 2 | 2 |
4 | 7 | 1991.80 | 22 | 11.17 | 3114 | 765 | 3.20 / 933.13 | 2 | 2 |
5 | 13 | 966.60 | 45 | 12.93 | 1695 | 986 | 4.19 / 934.11 | 2 | 2 |
6 | 13 | 24.76 | 45 | 14.16 | 344 | 219 | 4.40 / 934.33 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.16 | 308 | 785 | 5.19 / 935.12 | 2 | 4 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 28 | 14.02 | 452 | 177 | 0.18 / 926.52 | 2 | 2 |
2 | 12 | 1119.64 | 65 | 10.33 | 1851 | 1243 | 1.42 / 927.76 | 2 | 2 |
3 | 7 | 1116.52 | 22 | 11.97 | 1891 | 498 | 1.92 / 928.26 | 2 | 2 |
4 | 13 | 849.16 | 45 | 12.97 | 1526 | 891 | 2.81 / 929.15 | 2 | 2 |
5 | 8 | 0.00 | 180 | 14.11 | 305 | 775 | 3.58 / 929.93 | 2 | 3 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 26 | 14.00 | 468 | 170 | 0.17 / 922.86 | 2 | 2 |
2 | 3 | 1068.76 | 2 | 12.95 | 1855 | 48 | 0.22 / 922.91 | 2 | 2 |
3 | 12 | 1137.80 | 65 | 10.43 | 1862 | 1262 | 1.48 / 924.17 | 2 | 2 |
4 | 7 | 1134.56 | 22 | 11.98 | 1901 | 501 | 1.98 / 924.67 | 2 | 2 |
5 | 13 | 864.68 | 45 | 13.02 | 1528 | 895 | 2.88 / 925.57 | 2 | 2 |
6 | 8 | 0.12 | 180 | 14.13 | 305 | 776 | 3.65 / 926.34 | 2 | 3 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 28 | 14.06 | 454 | 179 | 0.18 / 919.27 | 2 | 2 |
2 | 3 | 968.92 | -1 | 14.06 | 454 | 0 | 0.00 / 919.27 | 2 | 2 |
3 | 12 | 1158.00 | 65 | 10.63 | 1903 | 1315 | 1.49 / 920.59 | 2 | 2 |
4 | 7 | 1154.00 | 22 | 12.02 | 1922 | 508 | 2.00 / 921.10 | 2 | 2 |
5 | 13 | 739.80 | 45 | 13.16 | 1377 | 815 | 2.82 / 921.91 | 2 | 2 |
6 | 8 | -0.16 | 180 | 14.13 | 307 | 781 | 3.60 / 922.69 | 2 | 11 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 28 | 14.02 | 451 | 177 | 0.18 / 914.21 | 2 | 2 |
2 | 12 | 1089.24 | 5 | 12.54 | 1855 | 116 | 0.29 / 914.33 | 2 | 2 |
3 | 12 | 1995.48 | 65 | 10.60 | 3093 | 2131 | 2.42 / 916.46 | 2 | 2 |
4 | 7 | 1987.48 | 22 | 11.20 | 3094 | 762 | 3.19 / 917.22 | 2 | 2 |
5 | 13 | 1092.76 | 45 | 12.78 | 1883 | 1083 | 4.27 / 918.31 | 2 | 2 |
6 | 8 | 0.28 | 180 | 14.16 | 309 | 788 | 5.06 / 919.09 | 2 | 4 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 27 | 14.02 | 454 | 172 | 0.17 / 910.51 | 2 | 2 |
2 | 12 | 1128.88 | 65 | 10.45 | 1851 | 1257 | 1.43 / 911.77 | 2 | 2 |
3 | 7 | 1125.76 | 22 | 11.97 | 1888 | 497 | 1.93 / 912.27 | 2 | 2 |
4 | 13 | 993.24 | 45 | 12.79 | 1709 | 984 | 2.91 / 913.25 | 2 | 2 |
5 | 8 | -0.08 | 180 | 14.10 | 309 | 784 | 3.69 / 914.04 | 2 | 2 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 28 | 14.03 | 465 | 183 | 0.18 / 907.03 | 2 | 2 |
2 | 12 | 1104.32 | 65 | 10.56 | 1830 | 1256 | 1.44 / 908.28 | 2 | 2 |
3 | 7 | 1100.56 | 22 | 12.02 | 1855 | 491 | 1.93 / 908.77 | 2 | 2 |
4 | 13 | 703.40 | 45 | 13.17 | 1328 | 787 | 2.72 / 909.56 | 2 | 2 |
5 | 8 | -0.04 | 180 | 14.11 | 308 | 782 | 3.50 / 910.34 | 2 | 3 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 26 | 14.08 | 471 | 172 | 0.17 / 903.42 | 2 | 2 |
2 | 3 | 1042.60 | 1 | 13.09 | 1797 | 24 | 0.20 / 903.44 | 2 | 2 |
3 | 12 | 1127.64 | 65 | 11.10 | 1868 | 1348 | 1.54 / 904.79 | 2 | 2 |
4 | 7 | 1123.52 | 22 | 12.06 | 1885 | 500 | 2.04 / 905.29 | 2 | 2 |
5 | 13 | 716.36 | 45 | 13.22 | 1320 | 785 | 2.83 / 906.07 | 2 | 2 |
6 | 8 | 0.28 | 180 | 14.13 | 303 | 771 | 3.60 / 906.84 | 2 | 3 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 25 | 14.09 | 464 | 163 | 0.16 / 898.17 | 2 | 2 |
2 | 3 | 1072.96 | 3 | 13.11 | 1856 | 73 | 0.24 / 898.25 | 2 | 2 |
3 | 12 | 1113.36 | 5 | 12.91 | 1895 | 122 | 0.36 / 898.37 | 2 | 2 |
4 | 12 | 1996.20 | 65 | 11.19 | 3102 | 2256 | 2.62 / 900.62 | 2 | 2 |
5 | 7 | 1988.44 | 22 | 11.37 | 3092 | 773 | 3.39 / 901.40 | 2 | 2 |
6 | 13 | 1041.48 | 45 | 12.91 | 1808 | 1050 | 4.44 / 902.45 | 2 | 2 |
7 | 8 | 0.08 | 180 | 14.20 | 311 | 795 | 5.23 / 903.24 | 2 | 3 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 28 | 14.07 | 458 | 180 | 0.18 / 892.65 | 2 | 2 |
2 | 3 | 956.28 | -1 | 14.07 | 458 | 0 | 0.00 / 892.65 | 2 | 2 |
3 | 12 | 1114.96 | 8 | 11.29 | 1868 | 169 | 0.35 / 892.82 | 2 | 2 |
4 | 12 | 1998.68 | 65 | 8.55 | 3004 | 1669 | 2.02 / 894.49 | 2 | 2 |
5 | 7 | 1992.24 | 22 | 11.07 | 3081 | 750 | 2.77 / 895.24 | 2 | 2 |
6 | 13 | 1570.12 | 45 | 12.25 | 2521 | 1390 | 4.16 / 896.63 | 2 | 2 |
7 | 13 | 458.92 | 45 | 13.55 | 964 | 588 | 4.75 / 897.22 | 2 | 2 |
8 | 8 | 0.36 | 180 | 14.16 | 310 | 790 | 5.54 / 898.01 | 2 | 4 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 26 | 14.08 | 470 | 172 | 0.17 / 887.32 | 2 | 2 |
2 | 3 | 1038.04 | 1 | 13.08 | 1813 | 24 | 0.20 / 887.35 | 2 | 2 |
3 | 12 | 1124.12 | 8 | 11.28 | 1886 | 170 | 0.37 / 887.52 | 2 | 2 |
4 | 12 | 1999.08 | 65 | 8.70 | 3009 | 1702 | 2.07 / 889.22 | 2 | 2 |
5 | 7 | 1992.32 | 22 | 11.05 | 3082 | 749 | 2.82 / 889.97 | 2 | 2 |
6 | 13 | 1407.76 | 45 | 12.44 | 2296 | 1285 | 4.10 / 891.25 | 2 | 2 |
7 | 13 | 294.36 | 45 | 13.76 | 719 | 445 | 4.55 / 891.70 | 2 | 2 |
8 | 8 | -0.08 | 180 | 14.17 | 304 | 775 | 5.32 / 892.47 | 2 | 5 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 28 | 14.10 | 454 | 179 | 0.18 / 882.04 | 2 | 2 |
2 | 3 | 954.44 | -1 | 14.10 | 454 | 0 | 0.00 / 882.04 | 2 | 2 |
3 | 12 | 1116.28 | 8 | 11.18 | 1856 | 166 | 0.35 / 882.21 | 2 | 2 |
4 | 12 | 2001.08 | 65 | 8.76 | 3008 | 1713 | 2.06 / 883.92 | 2 | 2 |
5 | 7 | 1995.00 | 22 | 11.10 | 3085 | 753 | 2.81 / 884.68 | 2 | 2 |
6 | 13 | 1549.84 | 45 | 12.29 | 2486 | 1375 | 4.19 / 886.05 | 2 | 2 |
7 | 13 | 136.92 | 45 | 13.99 | 506 | 319 | 4.50 / 886.37 | 2 | 2 |
8 | 8 | 0.20 | 180 | 14.19 | 306 | 782 | 5.29 / 887.15 | 2 | 3 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 28 | 14.10 | 460 | 182 | 0.18 / 876.96 | 2 | 2 |
2 | 12 | 1107.56 | 8 | 11.10 | 1860 | 165 | 0.35 / 877.12 | 2 | 2 |
3 | 12 | 1999.80 | 55 | 8.82 | 3009 | 1460 | 1.81 / 878.58 | 2 | 2 |
4 | 7 | 1994.12 | 22 | 11.11 | 3082 | 753 | 2.56 / 879.34 | 2 | 2 |
5 | 13 | 1721.76 | 35 | 12.23 | 2732 | 1169 | 3.73 / 880.51 | 2 | 2 |
6 | 13 | 651.20 | 35 | 13.39 | 1230 | 576 | 4.31 / 881.08 | 2 | 2 |
7 | 8 | 0.08 | 180 | 14.18 | 306 | 781 | 5.09 / 881.86 | 2 | 6 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 28 | 14.12 | 446 | 176 | 0.18 / 872.04 | 2 | 2 |
2 | 12 | 1104.36 | 8 | 11.07 | 1847 | 164 | 0.34 / 872.20 | 2 | 2 |
3 | 12 | 1998.44 | 55 | 8.63 | 2997 | 1423 | 1.76 / 873.62 | 2 | 2 |
4 | 7 | 1992.44 | 22 | 11.10 | 3095 | 756 | 2.52 / 874.38 | 2 | 2 |
5 | 13 | 1580.52 | 35 | 12.42 | 2528 | 1099 | 3.62 / 875.48 | 2 | 2 |
6 | 13 | 560.80 | 35 | 13.47 | 1116 | 526 | 4.14 / 876.00 | 2 | 2 |
7 | 8 | 0.04 | 180 | 14.19 | 303 | 774 | 4.92 / 876.78 | 2 | 9 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 26 | 14.14 | 450 | 165 | 0.17 / 867.01 | 2 | 2 |
2 | 3 | 1040.00 | 1 | 13.10 | 1807 | 24 | 0.19 / 867.03 | 2 | 2 |
3 | 12 | 1127.24 | 8 | 11.05 | 1899 | 168 | 0.36 / 867.20 | 2 | 2 |
4 | 12 | 2000.36 | 55 | 8.72 | 3022 | 1449 | 1.81 / 868.65 | 2 | 2 |
5 | 7 | 1994.64 | 22 | 11.12 | 3084 | 754 | 2.56 / 869.40 | 2 | 2 |
6 | 13 | 1575.64 | 35 | 12.43 | 2540 | 1105 | 3.67 / 870.51 | 2 | 2 |
7 | 13 | 679.80 | 35 | 13.37 | 1276 | 597 | 4.26 / 871.11 | 2 | 2 |
8 | 8 | -0.04 | 180 | 14.21 | 295 | 755 | 5.02 / 871.86 | 2 | 2 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 28 | 14.14 | 450 | 178 | 0.18 / 861.90 | 2 | 2 |
2 | 3 | 947.96 | -1 | 14.14 | 450 | 0 | 0.00 / 861.90 | 2 | 2 |
3 | 12 | 1115.92 | 8 | 11.30 | 1876 | 170 | 0.35 / 862.07 | 2 | 2 |
4 | 12 | 1998.88 | 52 | 8.73 | 3010 | 1366 | 1.71 / 863.43 | 2 | 2 |
5 | 7 | 1993.00 | 22 | 11.17 | 3085 | 758 | 2.47 / 864.19 | 2 | 2 |
6 | 13 | 1722.24 | 39 | 12.21 | 2733 | 1301 | 3.77 / 865.49 | 2 | 2 |
7 | 13 | 533.84 | 39 | 13.50 | 1082 | 570 | 4.34 / 866.06 | 2 | 2 |
8 | 8 | -0.04 | 180 | 14.19 | 306 | 782 | 5.12 / 866.84 | 2 | 3 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 28 | 14.15 | 452 | 179 | 0.18 / 856.62 | 2 | 2 |
2 | 12 | 1083.92 | 8 | 11.18 | 1821 | 163 | 0.34 / 856.78 | 2 | 2 |
3 | 12 | 1999.20 | 52 | 8.63 | 2985 | 1340 | 1.68 / 858.12 | 2 | 2 |
4 | 7 | 1993.96 | 22 | 11.16 | 3076 | 755 | 2.44 / 858.88 | 2 | 2 |
5 | 13 | 1726.28 | 39 | 12.20 | 2737 | 1302 | 3.74 / 860.18 | 2 | 2 |
6 | 13 | 804.96 | 39 | 13.21 | 1460 | 752 | 4.49 / 860.93 | 2 | 2 |
7 | 8 | 0.24 | 180 | 14.19 | 308 | 787 | 5.28 / 861.72 | 2 | 5 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 28 | 14.15 | 444 | 176 | 0.18 / 851.49 | 2 | 2 |
2 | 12 | 1111.76 | 8 | 11.09 | 1854 | 164 | 0.34 / 851.65 | 2 | 2 |
3 | 12 | 1999.36 | 52 | 8.81 | 2989 | 1369 | 1.71 / 853.02 | 2 | 2 |
4 | 7 | 1993.60 | 22 | 11.18 | 3078 | 757 | 2.47 / 853.78 | 2 | 2 |
5 | 13 | 1568.92 | 39 | 12.38 | 2532 | 1223 | 3.69 / 855.00 | 2 | 2 |
6 | 13 | 662.28 | 39 | 13.36 | 1267 | 660 | 4.35 / 855.66 | 2 | 2 |
7 | 8 | -0.04 | 180 | 14.19 | 305 | 779 | 5.13 / 856.44 | 2 | 4 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 28 | 14.16 | 448 | 178 | 0.18 / 846.40 | 2 | 2 |
2 | 12 | 1104.00 | 8 | 11.22 | 1858 | 167 | 0.34 / 846.57 | 2 | 2 |
3 | 12 | 2003.00 | 46 | 8.88 | 3005 | 1227 | 1.57 / 847.80 | 2 | 2 |
4 | 7 | 1998.04 | 22 | 11.20 | 3083 | 760 | 2.33 / 848.56 | 2 | 2 |
5 | 13 | 1729.44 | 39 | 12.18 | 2763 | 1312 | 3.64 / 849.87 | 2 | 2 |
6 | 13 | 665.76 | 39 | 13.34 | 1274 | 663 | 4.31 / 850.53 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.18 | 305 | 778 | 5.09 / 851.31 | 2 | 4 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 28 | 14.18 | 439 | 174 | 0.17 / 841.46 | 2 | 2 |
2 | 12 | 1101.88 | 8 | 11.14 | 1847 | 165 | 0.34 / 841.63 | 2 | 2 |
3 | 12 | 2008.80 | 46 | 8.68 | 2996 | 1196 | 1.54 / 842.82 | 2 | 2 |
4 | 7 | 2004.32 | 22 | 11.25 | 3102 | 768 | 2.30 / 843.59 | 2 | 2 |
5 | 13 | 1618.28 | 39 | 12.35 | 2591 | 1248 | 3.55 / 844.84 | 2 | 2 |
6 | 13 | 604.56 | 39 | 13.43 | 1175 | 615 | 4.17 / 845.45 | 2 | 2 |
7 | 8 | 0.08 | 180 | 14.20 | 302 | 772 | 4.94 / 846.23 | 2 | 4 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 28 | 14.18 | 441 | 175 | 0.18 / 836.28 | 2 | 2 |
2 | 12 | 1116.68 | 8 | 11.23 | 1888 | 170 | 0.34 / 836.45 | 2 | 2 |
3 | 12 | 2009.12 | 46 | 8.76 | 2982 | 1202 | 1.55 / 837.65 | 2 | 2 |
4 | 7 | 2004.48 | 22 | 11.19 | 3105 | 764 | 2.31 / 838.41 | 2 | 2 |
5 | 13 | 1871.56 | 39 | 12.00 | 2922 | 1367 | 3.68 / 839.78 | 2 | 2 |
6 | 13 | 782.08 | 39 | 13.23 | 1427 | 736 | 4.41 / 840.52 | 2 | 2 |
7 | 8 | 0.04 | 180 | 14.20 | 302 | 772 | 5.19 / 841.29 | 2 | 3 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 28 | 14.17 | 445 | 177 | 0.18 / 830.98 | 2 | 2 |
2 | 12 | 1092.68 | 8 | 11.27 | 1839 | 166 | 0.34 / 831.14 | 2 | 2 |
3 | 12 | 2014.96 | 46 | 8.73 | 3024 | 1214 | 1.56 / 832.36 | 2 | 2 |
4 | 7 | 2010.72 | 22 | 11.23 | 3107 | 768 | 2.32 / 833.13 | 2 | 2 |
5 | 13 | 1876.64 | 39 | 11.97 | 2953 | 1379 | 3.70 / 834.50 | 2 | 2 |
6 | 13 | 918.92 | 39 | 13.08 | 1627 | 830 | 4.53 / 835.33 | 2 | 2 |
7 | 8 | 0.04 | 180 | 14.22 | 300 | 768 | 5.30 / 836.10 | 2 | 3 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 28 | 14.21 | 443 | 176 | 0.18 / 825.95 | 2 | 2 |
2 | 12 | 1124.84 | 8 | 11.30 | 1890 | 171 | 0.35 / 826.12 | 2 | 2 |
3 | 12 | 2001.84 | 46 | 9.02 | 2994 | 1242 | 1.59 / 827.36 | 2 | 2 |
4 | 7 | 1996.80 | 22 | 11.19 | 3089 | 760 | 2.35 / 828.12 | 2 | 2 |
5 | 13 | 1602.40 | 39 | 12.35 | 2568 | 1237 | 3.59 / 829.36 | 2 | 2 |
6 | 13 | 697.72 | 39 | 13.32 | 1293 | 672 | 4.26 / 830.03 | 2 | 2 |
7 | 8 | 0.04 | 180 | 14.20 | 302 | 772 | 5.03 / 830.80 | 2 | 4 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 27 | 14.20 | 445 | 171 | 0.17 / 820.91 | 2 | 2 |
2 | 3 | 1015.96 | 1 | 12.89 | 1777 | 23 | 0.19 / 820.93 | 2 | 2 |
3 | 12 | 1119.00 | 8 | 11.51 | 1883 | 173 | 0.37 / 821.11 | 2 | 2 |
4 | 12 | 2000.60 | 46 | 9.10 | 2997 | 1255 | 1.62 / 822.36 | 2 | 2 |
5 | 7 | 1995.40 | 22 | 11.25 | 3083 | 763 | 2.38 / 823.12 | 2 | 2 |
6 | 13 | 1582.68 | 39 | 12.41 | 2532 | 1225 | 3.61 / 824.35 | 2 | 2 |
7 | 13 | 672.96 | 39 | 13.36 | 1260 | 657 | 4.27 / 825.01 | 2 | 2 |
8 | 8 | -0.20 | 180 | 14.19 | 299 | 764 | 5.03 / 825.77 | 2 | 3 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 29 | 14.19 | 444 | 183 | 0.18 / 815.74 | 2 | 2 |
2 | 3 | 961.80 | -1 | 14.19 | 444 | 0 | 0.00 / 815.74 | 2 | 2 |
3 | 3 | 1018.08 | 1 | 12.86 | 1781 | 23 | 0.21 / 815.76 | 2 | 2 |
4 | 12 | 1123.72 | 8 | 11.64 | 1893 | 176 | 0.38 / 815.94 | 2 | 2 |
5 | 12 | 2001.56 | 46 | 9.13 | 3011 | 1265 | 1.65 / 817.20 | 2 | 2 |
6 | 7 | 1996.44 | 22 | 11.25 | 3079 | 762 | 2.41 / 817.96 | 2 | 2 |
7 | 13 | 1723.16 | 39 | 12.22 | 2736 | 1304 | 3.71 / 819.27 | 2 | 2 |
8 | 13 | 800.84 | 39 | 13.23 | 1442 | 744 | 4.46 / 820.01 | 2 | 2 |
9 | 8 | 0.04 | 180 | 14.23 | 284 | 727 | 5.18 / 820.74 | 2 | 3 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 28 | 14.19 | 453 | 180 | 0.18 / 810.68 | 2 | 2 |
2 | 3 | 1024.12 | 1 | 12.98 | 1786 | 23 | 0.20 / 810.70 | 2 | 2 |
3 | 12 | 1122.92 | 8 | 11.51 | 1893 | 174 | 0.38 / 810.88 | 2 | 2 |
4 | 12 | 2000.84 | 46 | 9.13 | 2994 | 1257 | 1.63 / 812.14 | 2 | 2 |
5 | 7 | 1995.80 | 22 | 11.25 | 3095 | 766 | 2.40 / 812.90 | 2 | 2 |
6 | 13 | 1592.88 | 39 | 12.37 | 2553 | 1232 | 3.63 / 814.13 | 2 | 2 |
7 | 13 | 680.08 | 39 | 13.35 | 1273 | 663 | 4.30 / 814.80 | 2 | 2 |
8 | 8 | -0.08 | 180 | 14.21 | 297 | 760 | 5.06 / 815.56 | 2 | 3 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 28 | 14.18 | 452 | 179 | 0.18 / 805.58 | 2 | 2 |
2 | 12 | 1116.36 | 8 | 11.48 | 1874 | 172 | 0.35 / 805.75 | 2 | 2 |
3 | 12 | 2000.72 | 46 | 9.09 | 3018 | 1262 | 1.61 / 807.02 | 2 | 2 |
4 | 7 | 1995.68 | 22 | 11.27 | 3088 | 766 | 2.38 / 807.78 | 2 | 2 |
5 | 13 | 1727.92 | 39 | 12.21 | 2741 | 1305 | 3.68 / 809.09 | 2 | 2 |
6 | 13 | 658.12 | 39 | 13.36 | 1244 | 648 | 4.33 / 809.73 | 2 | 2 |
7 | 8 | -0.24 | 180 | 14.20 | 300 | 767 | 5.10 / 810.50 | 2 | 3 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 28 | 14.19 | 436 | 173 | 0.17 / 800.52 | 2 | 2 |
2 | 12 | 1110.64 | 8 | 11.57 | 1863 | 172 | 0.35 / 800.69 | 2 | 2 |
3 | 12 | 2000.28 | 46 | 9.24 | 3032 | 1289 | 1.63 / 801.98 | 2 | 2 |
4 | 7 | 1994.80 | 22 | 11.28 | 3079 | 764 | 2.40 / 802.75 | 2 | 2 |
5 | 13 | 1593.48 | 39 | 12.37 | 2546 | 1228 | 3.63 / 803.97 | 2 | 2 |
6 | 13 | 664.92 | 39 | 13.36 | 1252 | 652 | 4.28 / 804.63 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.17 | 304 | 775 | 5.05 / 805.40 | 2 | 3 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 28 | 14.22 | 439 | 175 | 0.17 / 795.56 | 2 | 2 |
2 | 12 | 1098.12 | 8 | 11.58 | 1861 | 172 | 0.35 / 795.74 | 2 | 2 |
3 | 12 | 2000.44 | 46 | 9.36 | 3029 | 1304 | 1.65 / 797.04 | 2 | 2 |
4 | 7 | 1995.00 | 22 | 11.29 | 3087 | 767 | 2.42 / 797.81 | 2 | 2 |
5 | 13 | 1582.68 | 39 | 12.38 | 2544 | 1228 | 3.65 / 799.03 | 2 | 2 |
6 | 13 | 534.12 | 39 | 13.50 | 1066 | 561 | 4.21 / 799.60 | 2 | 2 |
7 | 8 | 0.08 | 180 | 14.20 | 294 | 751 | 4.96 / 800.35 | 2 | 3 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 27 | 14.21 | 445 | 171 | 0.17 / 790.49 | 2 | 2 |
2 | 3 | 1017.96 | 1 | 12.92 | 1772 | 23 | 0.19 / 790.52 | 2 | 2 |
3 | 12 | 1126.08 | 8 | 11.76 | 1909 | 180 | 0.37 / 790.70 | 2 | 2 |
4 | 12 | 2001.76 | 46 | 9.56 | 3011 | 1324 | 1.70 / 792.02 | 2 | 2 |
5 | 7 | 1996.36 | 22 | 11.27 | 3084 | 765 | 2.46 / 792.78 | 2 | 2 |
6 | 13 | 1594.96 | 39 | 12.39 | 2549 | 1232 | 3.69 / 794.02 | 2 | 2 |
7 | 13 | 665.20 | 39 | 13.36 | 1253 | 653 | 4.35 / 794.67 | 2 | 2 |
8 | 8 | 0.00 | 180 | 14.23 | 281 | 720 | 5.07 / 795.39 | 2 | 5 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 29 | 14.19 | 447 | 184 | 0.18 / 785.40 | 2 | 2 |
2 | 3 | 955.36 | -1 | 14.19 | 447 | 0 | 0.00 / 785.40 | 2 | 2 |
3 | 12 | 1130.36 | 8 | 11.72 | 1909 | 179 | 0.36 / 785.58 | 2 | 2 |
4 | 12 | 1999.60 | 46 | 9.63 | 3017 | 1336 | 1.70 / 786.91 | 2 | 2 |
5 | 7 | 1993.56 | 22 | 11.27 | 3087 | 765 | 2.46 / 787.68 | 2 | 2 |
6 | 13 | 1575.00 | 39 | 12.41 | 2532 | 1225 | 3.69 / 788.90 | 2 | 2 |
7 | 13 | 651.20 | 39 | 13.37 | 1233 | 643 | 4.33 / 789.55 | 2 | 2 |
8 | 8 | -0.20 | 180 | 14.17 | 304 | 775 | 5.11 / 790.32 | 2 | 3 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 28 | 14.18 | 458 | 182 | 0.18 / 780.37 | 2 | 2 |
2 | 3 | 1023.00 | 1 | 13.01 | 1796 | 23 | 0.21 / 780.39 | 2 | 2 |
3 | 12 | 1132.80 | 8 | 11.74 | 1903 | 179 | 0.38 / 780.57 | 2 | 2 |
4 | 12 | 2000.64 | 42 | 9.63 | 3036 | 1228 | 1.61 / 781.80 | 2 | 2 |
5 | 7 | 1995.04 | 22 | 11.34 | 3084 | 769 | 2.38 / 782.57 | 2 | 2 |
6 | 13 | 1589.60 | 39 | 12.39 | 2549 | 1232 | 3.61 / 783.80 | 2 | 2 |
7 | 13 | 664.72 | 39 | 13.35 | 1255 | 653 | 4.27 / 784.45 | 2 | 2 |
8 | 8 | -0.08 | 180 | 14.18 | 299 | 763 | 5.03 / 785.21 | 2 | 4 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 28 | 14.19 | 446 | 177 | 0.18 / 775.27 | 2 | 2 |
2 | 12 | 1104.36 | 8 | 11.71 | 1873 | 175 | 0.35 / 775.45 | 2 | 2 |
3 | 12 | 2002.04 | 42 | 9.57 | 3020 | 1214 | 1.57 / 776.66 | 2 | 2 |
4 | 7 | 1997.20 | 22 | 11.29 | 3091 | 768 | 2.33 / 777.43 | 2 | 2 |
5 | 13 | 1726.72 | 39 | 12.23 | 2736 | 1305 | 3.64 / 778.73 | 2 | 2 |
6 | 13 | 682.32 | 39 | 13.33 | 1293 | 672 | 4.31 / 779.41 | 2 | 2 |
7 | 8 | -0.24 | 180 | 14.16 | 305 | 777 | 5.09 / 780.18 | 2 | 3 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 28 | 14.19 | 446 | 177 | 0.18 / 770.15 | 2 | 2 |
2 | 12 | 1090.40 | 8 | 11.67 | 1849 | 173 | 0.35 / 770.32 | 2 | 2 |
3 | 12 | 2000.08 | 42 | 9.62 | 3015 | 1218 | 1.57 / 771.54 | 2 | 2 |
4 | 7 | 1994.32 | 22 | 11.28 | 3094 | 768 | 2.34 / 772.31 | 2 | 2 |
5 | 13 | 1710.44 | 39 | 12.23 | 2713 | 1294 | 3.63 / 773.60 | 2 | 2 |
6 | 13 | 772.20 | 39 | 13.23 | 1409 | 727 | 4.36 / 774.33 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.17 | 301 | 768 | 5.12 / 775.10 | 2 | 3 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 27 | 14.23 | 440 | 169 | 0.17 / 765.21 | 2 | 2 |
2 | 3 | 1032.76 | 1 | 13.01 | 1806 | 23 | 0.19 / 765.23 | 2 | 2 |
3 | 12 | 1125.36 | 8 | 11.79 | 1908 | 180 | 0.37 / 765.41 | 2 | 2 |
4 | 12 | 2004.16 | 42 | 9.80 | 3035 | 1249 | 1.62 / 766.66 | 2 | 2 |
5 | 7 | 1999.40 | 22 | 11.32 | 3097 | 771 | 2.39 / 767.43 | 2 | 2 |
6 | 13 | 1582.48 | 39 | 12.41 | 2536 | 1227 | 3.62 / 768.66 | 2 | 2 |
7 | 13 | 535.88 | 39 | 13.50 | 1071 | 564 | 4.18 / 769.22 | 2 | 2 |
8 | 8 | 0.08 | 180 | 14.19 | 293 | 748 | 4.93 / 769.97 | 2 | 3 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 28 | 14.18 | 452 | 179 | 0.18 / 760.20 | 2 | 2 |
2 | 3 | 969.40 | -1 | 14.18 | 452 | 0 | 0.00 / 760.20 | 2 | 2 |
3 | 3 | 1025.16 | 1 | 12.92 | 1785 | 23 | 0.20 / 760.22 | 2 | 2 |
4 | 12 | 1123.24 | 8 | 11.80 | 1903 | 180 | 0.38 / 760.40 | 2 | 2 |
5 | 12 | 2004.24 | 42 | 9.82 | 3046 | 1256 | 1.64 / 761.66 | 2 | 2 |
6 | 7 | 1999.20 | 22 | 11.31 | 3098 | 771 | 2.41 / 762.43 | 2 | 2 |
7 | 13 | 1474.28 | 39 | 12.50 | 2398 | 1169 | 3.58 / 763.60 | 2 | 2 |
8 | 13 | 720.40 | 39 | 13.30 | 1339 | 695 | 4.27 / 764.29 | 2 | 2 |
9 | 8 | -0.16 | 180 | 14.19 | 292 | 746 | 5.02 / 765.04 | 2 | 4 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 28 | 14.19 | 453 | 180 | 0.18 / 755.21 | 2 | 2 |
2 | 12 | 1114.28 | 8 | 11.68 | 1902 | 178 | 0.36 / 755.39 | 2 | 2 |
3 | 12 | 2000.68 | 42 | 9.98 | 3030 | 1270 | 1.63 / 756.66 | 2 | 2 |
4 | 7 | 1995.68 | 22 | 11.33 | 3087 | 769 | 2.40 / 757.43 | 2 | 2 |
5 | 13 | 1590.88 | 39 | 12.38 | 2543 | 1228 | 3.63 / 758.66 | 2 | 2 |
6 | 13 | 533.88 | 39 | 13.49 | 1086 | 571 | 4.20 / 759.23 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.15 | 310 | 790 | 4.99 / 760.02 | 2 | 3 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 27 | 14.16 | 466 | 178 | 0.18 / 750.22 | 2 | 2 |
2 | 3 | 1023.12 | 1 | 12.90 | 1794 | 23 | 0.20 / 750.24 | 2 | 2 |
3 | 12 | 1126.76 | 8 | 11.86 | 1905 | 181 | 0.38 / 750.42 | 2 | 2 |
4 | 12 | 2002.08 | 42 | 9.91 | 3041 | 1266 | 1.65 / 751.69 | 2 | 2 |
5 | 7 | 1996.64 | 22 | 11.34 | 3091 | 771 | 2.42 / 752.46 | 2 | 2 |
6 | 13 | 1597.92 | 39 | 12.40 | 2570 | 1243 | 3.66 / 753.70 | 2 | 2 |
7 | 13 | 559.32 | 39 | 13.48 | 1109 | 583 | 4.24 / 754.28 | 2 | 2 |
8 | 8 | -0.24 | 180 | 14.18 | 294 | 750 | 5.00 / 755.03 | 2 | 3 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 28 | 14.17 | 455 | 181 | 0.18 / 745.27 | 2 | 2 |
2 | 3 | 968.40 | -1 | 14.17 | 455 | 0 | 0.00 / 745.27 | 2 | 2 |
3 | 3 | 1026.48 | 1 | 12.83 | 1794 | 23 | 0.20 / 745.29 | 2 | 2 |
4 | 12 | 1136.72 | 8 | 11.78 | 1920 | 181 | 0.38 / 745.48 | 2 | 2 |
5 | 12 | 2001.28 | 42 | 10.13 | 3025 | 1287 | 1.67 / 746.76 | 2 | 2 |
6 | 7 | 1996.00 | 22 | 11.37 | 3098 | 775 | 2.45 / 747.54 | 2 | 2 |
7 | 13 | 1449.72 | 39 | 12.54 | 2366 | 1157 | 3.60 / 748.69 | 2 | 2 |
8 | 13 | 547.96 | 39 | 13.50 | 1089 | 573 | 4.18 / 749.27 | 2 | 2 |
9 | 8 | 0.04 | 180 | 14.16 | 302 | 770 | 4.95 / 750.04 | 2 | 4 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 27 | 14.18 | 466 | 178 | 0.18 / 740.26 | 2 | 2 |
2 | 12 | 1137.80 | 5 | 9.72 | 1893 | 92 | 0.27 / 740.35 | 2 | 2 |
3 | 12 | 2002.68 | 42 | 9.80 | 3010 | 1239 | 1.51 / 741.59 | 2 | 2 |
4 | 7 | 1997.88 | 22 | 11.38 | 3098 | 776 | 2.28 / 742.36 | 2 | 2 |
5 | 13 | 1728.04 | 39 | 12.28 | 2743 | 1314 | 3.60 / 743.68 | 2 | 2 |
6 | 13 | 666.40 | 39 | 13.38 | 1252 | 653 | 4.25 / 744.33 | 2 | 2 |
7 | 8 | -0.04 | 180 | 14.17 | 299 | 763 | 5.01 / 745.09 | 2 | 3 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 27 | 14.18 | 466 | 178 | 0.18 / 735.11 | 2 | 2 |
2 | 12 | 1122.60 | 5 | 10.11 | 1877 | 95 | 0.27 / 735.20 | 2 | 2 |
3 | 12 | 2000.96 | 42 | 9.75 | 2999 | 1228 | 1.50 / 736.43 | 2 | 2 |
4 | 7 | 1996.28 | 22 | 11.36 | 3096 | 774 | 2.28 / 737.20 | 2 | 2 |
5 | 13 | 1733.72 | 39 | 12.27 | 2747 | 1315 | 3.59 / 738.52 | 2 | 2 |
6 | 13 | 830.84 | 39 | 13.19 | 1506 | 775 | 4.36 / 739.29 | 2 | 2 |
7 | 8 | 0.12 | 180 | 14.16 | 308 | 785 | 5.15 / 740.08 | 2 | 4 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 27 | 14.21 | 452 | 173 | 0.17 / 730.10 | 2 | 2 |
2 | 12 | 1094.72 | 5 | 10.48 | 1855 | 97 | 0.27 / 730.20 | 2 | 2 |
3 | 12 | 2005.80 | 42 | 9.86 | 3004 | 1244 | 1.51 / 731.44 | 2 | 2 |
4 | 7 | 2000.96 | 22 | 11.38 | 3106 | 778 | 2.29 / 732.22 | 2 | 2 |
5 | 13 | 1591.40 | 39 | 12.40 | 2566 | 1241 | 3.53 / 733.46 | 2 | 2 |
6 | 13 | 692.48 | 39 | 13.33 | 1315 | 684 | 4.22 / 734.15 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.15 | 307 | 782 | 5.00 / 734.93 | 2 | 3 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 26 | 14.19 | 462 | 170 | 0.17 / 725.12 | 2 | 2 |
2 | 3 | 1020.88 | 1 | 12.62 | 1810 | 23 | 0.19 / 725.14 | 2 | 2 |
3 | 3 | 1020.04 | 1 | 12.43 | 1810 | 22 | 0.22 / 725.17 | 2 | 2 |
4 | 12 | 1127.32 | 5 | 10.64 | 1891 | 101 | 0.32 / 725.27 | 2 | 2 |
5 | 12 | 2005.88 | 42 | 10.02 | 3020 | 1271 | 1.59 / 726.54 | 2 | 2 |
6 | 7 | 2000.92 | 22 | 11.41 | 3098 | 778 | 2.36 / 727.32 | 2 | 2 |
7 | 13 | 1597.96 | 39 | 12.42 | 2555 | 1238 | 3.60 / 728.55 | 2 | 2 |
8 | 13 | 565.60 | 39 | 13.47 | 1132 | 595 | 4.20 / 729.15 | 2 | 2 |
9 | 8 | 0.28 | 180 | 14.16 | 306 | 780 | 4.98 / 729.93 | 2 | 3 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 27 | 14.16 | 460 | 176 | 0.18 / 719.89 | 2 | 2 |
2 | 3 | 969.76 | -1 | 14.16 | 460 | 0 | 0.00 / 719.89 | 2 | 2 |
3 | 12 | 1152.12 | 5 | 10.79 | 1923 | 104 | 0.28 / 719.99 | 2 | 2 |
4 | 12 | 2006.96 | 42 | 10.01 | 3029 | 1273 | 1.55 / 721.26 | 2 | 2 |
5 | 7 | 2002.40 | 22 | 11.37 | 3099 | 775 | 2.33 / 722.04 | 2 | 2 |
6 | 13 | 1869.72 | 39 | 12.08 | 2931 | 1381 | 3.71 / 723.42 | 2 | 2 |
7 | 13 | 787.32 | 39 | 13.23 | 1447 | 747 | 4.46 / 724.17 | 2 | 2 |
8 | 8 | -0.04 | 180 | 14.14 | 309 | 786 | 5.24 / 724.95 | 2 | 3 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 27 | 14.16 | 468 | 179 | 0.18 / 714.90 | 2 | 2 |
2 | 3 | 1024.84 | 1 | 12.76 | 1776 | 23 | 0.20 / 714.92 | 2 | 2 |
3 | 12 | 1133.08 | 5 | 10.53 | 1900 | 100 | 0.30 / 715.02 | 2 | 2 |
4 | 12 | 2001.76 | 42 | 10.08 | 2989 | 1265 | 1.57 / 716.29 | 2 | 2 |
5 | 7 | 1996.84 | 22 | 11.35 | 3084 | 770 | 2.34 / 717.06 | 2 | 2 |
6 | 13 | 1731.04 | 39 | 12.26 | 2742 | 1311 | 3.65 / 718.37 | 2 | 2 |
7 | 13 | 539.32 | 39 | 13.50 | 1076 | 567 | 4.21 / 718.94 | 2 | 2 |
8 | 8 | -0.04 | 180 | 14.15 | 303 | 772 | 4.99 / 719.71 | 2 | 4 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 26 | 14.18 | 455 | 168 | 0.17 / 709.78 | 2 | 2 |
2 | 12 | 1128.96 | 5 | 11.29 | 1911 | 108 | 0.28 / 709.89 | 2 | 2 |
3 | 12 | 2002.28 | 42 | 10.14 | 3009 | 1281 | 1.56 / 711.17 | 2 | 2 |
4 | 7 | 1997.56 | 22 | 11.36 | 3090 | 772 | 2.33 / 711.94 | 2 | 2 |
5 | 13 | 1597.12 | 39 | 12.38 | 2562 | 1237 | 3.57 / 713.18 | 2 | 2 |
6 | 13 | 818.04 | 39 | 13.20 | 1479 | 761 | 4.33 / 713.94 | 2 | 2 |
7 | 8 | 0.16 | 180 | 14.14 | 308 | 784 | 5.11 / 714.72 | 2 | 6 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 26 | 14.18 | 454 | 167 | 0.17 / 704.80 | 2 | 2 |
2 | 12 | 1122.72 | 5 | 11.71 | 1908 | 112 | 0.28 / 704.91 | 2 | 2 |
3 | 12 | 1999.76 | 42 | 10.26 | 3020 | 1301 | 1.58 / 706.21 | 2 | 2 |
4 | 7 | 1994.08 | 22 | 11.36 | 3101 | 775 | 2.36 / 706.99 | 2 | 2 |
5 | 13 | 1452.08 | 39 | 12.52 | 2371 | 1158 | 3.51 / 708.15 | 2 | 2 |
6 | 13 | 693.12 | 39 | 13.33 | 1301 | 676 | 4.19 / 708.82 | 2 | 2 |
7 | 8 | -0.20 | 180 | 14.12 | 310 | 788 | 4.98 / 709.61 | 2 | 3 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 27 | 14.17 | 466 | 178 | 0.18 / 699.72 | 2 | 2 |
2 | 3 | 956.48 | -1 | 14.17 | 466 | 0 | 0.00 / 699.72 | 2 | 2 |
3 | 12 | 1138.44 | 5 | 11.73 | 1923 | 113 | 0.29 / 699.83 | 2 | 2 |
4 | 12 | 2000.52 | 42 | 10.28 | 3021 | 1304 | 1.60 / 701.13 | 2 | 2 |
5 | 7 | 1995.24 | 22 | 11.34 | 3087 | 770 | 2.37 / 701.90 | 2 | 2 |
6 | 13 | 1724.48 | 39 | 12.24 | 2736 | 1306 | 3.67 / 703.21 | 2 | 2 |
7 | 13 | 632.08 | 39 | 13.38 | 1223 | 638 | 4.31 / 703.85 | 2 | 2 |
8 | 8 | 0.24 | 180 | 14.13 | 309 | 786 | 5.10 / 704.63 | 2 | 4 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 27 | 14.19 | 469 | 180 | 0.18 / 694.56 | 2 | 2 |
2 | 12 | 1118.52 | 5 | 11.58 | 1893 | 110 | 0.29 / 694.67 | 2 | 2 |
3 | 12 | 2003.48 | 42 | 10.27 | 3018 | 1302 | 1.59 / 695.97 | 2 | 2 |
4 | 7 | 1998.64 | 22 | 11.37 | 3106 | 777 | 2.37 / 696.75 | 2 | 2 |
5 | 13 | 1597.60 | 39 | 12.36 | 2559 | 1234 | 3.60 / 697.98 | 2 | 2 |
6 | 13 | 563.32 | 39 | 13.45 | 1127 | 591 | 4.19 / 698.57 | 2 | 2 |
7 | 13 | 6.44 | 39 | 14.21 | 322 | 178 | 4.37 / 698.75 | 2 | 2 |
8 | 8 | -0.16 | 180 | 14.10 | 310 | 787 | 5.16 / 699.54 | 2 | 11 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 27 | 14.21 | 464 | 178 | 0.18 / 689.55 | 2 | 2 |
2 | 12 | 1138.16 | 5 | 11.82 | 1932 | 114 | 0.29 / 689.67 | 2 | 2 |
3 | 12 | 2004.72 | 42 | 10.33 | 3034 | 1316 | 1.61 / 690.98 | 2 | 2 |
4 | 7 | 1999.28 | 22 | 11.32 | 3096 | 771 | 2.38 / 691.76 | 2 | 2 |
5 | 13 | 1583.24 | 39 | 12.38 | 2538 | 1225 | 3.60 / 692.98 | 2 | 2 |
6 | 13 | 639.92 | 39 | 13.36 | 1224 | 638 | 4.24 / 693.62 | 2 | 2 |
7 | 8 | 0.08 | 180 | 14.15 | 299 | 762 | 5.00 / 694.38 | 2 | 4 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 27 | 14.18 | 461 | 176 | 0.18 / 684.50 | 2 | 2 |
2 | 12 | 1134.36 | 5 | 11.90 | 1919 | 114 | 0.29 / 684.61 | 2 | 2 |
3 | 12 | 2003.36 | 42 | 10.37 | 3031 | 1320 | 1.61 / 685.93 | 2 | 2 |
4 | 7 | 1998.04 | 22 | 11.36 | 3101 | 775 | 2.39 / 686.71 | 2 | 2 |
5 | 13 | 1587.80 | 39 | 12.38 | 2550 | 1231 | 3.62 / 687.94 | 2 | 2 |
6 | 13 | 662.88 | 39 | 13.35 | 1257 | 654 | 4.27 / 688.59 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.13 | 308 | 783 | 5.05 / 689.38 | 2 | 3 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 28 | 14.20 | 462 | 184 | 0.18 / 679.26 | 2 | 2 |
2 | 3 | 972.92 | -1 | 14.20 | 462 | 0 | 0.00 / 679.26 | 2 | 2 |
3 | 12 | 1153.48 | 5 | 11.93 | 1951 | 116 | 0.30 / 679.38 | 2 | 2 |
4 | 12 | 2002.56 | 42 | 10.42 | 3047 | 1333 | 1.63 / 680.71 | 2 | 2 |
5 | 7 | 1997.16 | 23 | 11.36 | 3091 | 808 | 2.44 / 681.52 | 2 | 2 |
6 | 13 | 1717.56 | 39 | 12.24 | 2725 | 1301 | 3.74 / 682.82 | 2 | 2 |
7 | 13 | 755.68 | 39 | 13.23 | 1400 | 722 | 4.46 / 683.54 | 2 | 2 |
8 | 8 | -0.04 | 180 | 14.13 | 307 | 781 | 5.25 / 684.32 | 2 | 4 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 27 | 14.19 | 462 | 177 | 0.18 / 674.27 | 2 | 2 |
2 | 3 | 1021.60 | 1 | 12.28 | 1819 | 22 | 0.20 / 674.29 | 2 | 2 |
3 | 12 | 1129.96 | 5 | 11.90 | 1920 | 114 | 0.31 / 674.41 | 2 | 2 |
4 | 12 | 2005.16 | 42 | 10.45 | 3058 | 1342 | 1.66 / 675.75 | 2 | 2 |
5 | 7 | 2000.20 | 22 | 11.32 | 3102 | 773 | 2.43 / 676.52 | 2 | 2 |
6 | 13 | 1584.36 | 39 | 12.36 | 2546 | 1227 | 3.66 / 677.75 | 2 | 2 |
7 | 13 | 525.48 | 39 | 13.49 | 1059 | 557 | 4.21 / 678.31 | 2 | 2 |
8 | 8 | 0.16 | 180 | 14.14 | 302 | 769 | 4.98 / 679.08 | 2 | 3 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 28 | 14.18 | 456 | 181 | 0.18 / 669.47 | 2 | 2 |
2 | 3 | 955.24 | -1 | 14.18 | 456 | 0 | 0.00 / 669.47 | 2 | 2 |
3 | 12 | 1138.24 | 5 | 11.94 | 1926 | 115 | 0.30 / 669.58 | 2 | 2 |
4 | 12 | 2002.00 | 42 | 10.55 | 3058 | 1355 | 1.65 / 670.94 | 2 | 2 |
5 | 7 | 1996.76 | 22 | 11.35 | 3091 | 772 | 2.42 / 671.71 | 2 | 2 |
6 | 13 | 1447.20 | 39 | 12.48 | 2366 | 1152 | 3.57 / 672.86 | 2 | 2 |
7 | 13 | 401.40 | 39 | 13.63 | 883 | 469 | 4.04 / 673.33 | 2 | 2 |
8 | 8 | -0.04 | 180 | 14.13 | 300 | 763 | 4.81 / 674.09 | 2 | 4 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 27 | 14.19 | 459 | 176 | 0.18 / 664.58 | 2 | 2 |
2 | 12 | 1119.24 | 5 | 11.91 | 1902 | 113 | 0.29 / 664.69 | 2 | 2 |
3 | 12 | 2001.56 | 42 | 10.51 | 3074 | 1357 | 1.65 / 666.05 | 2 | 2 |
4 | 7 | 1996.08 | 22 | 11.36 | 3088 | 772 | 2.42 / 666.82 | 2 | 2 |
5 | 13 | 1580.60 | 39 | 12.35 | 2529 | 1218 | 3.64 / 668.04 | 2 | 2 |
6 | 13 | 406.00 | 39 | 13.63 | 887 | 472 | 4.11 / 668.51 | 2 | 2 |
7 | 8 | -0.12 | 180 | 14.14 | 305 | 776 | 4.88 / 669.29 | 2 | 3 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 27 | 14.22 | 450 | 173 | 0.17 / 659.66 | 2 | 2 |
2 | 12 | 1100.92 | 5 | 11.97 | 1866 | 112 | 0.28 / 659.77 | 2 | 2 |
3 | 12 | 2002.60 | 42 | 10.45 | 3075 | 1350 | 1.63 / 661.12 | 2 | 2 |
4 | 7 | 1997.16 | 22 | 11.33 | 3092 | 771 | 2.40 / 661.89 | 2 | 2 |
5 | 13 | 1452.80 | 39 | 12.46 | 2388 | 1160 | 3.57 / 663.05 | 2 | 2 |
6 | 13 | 541.84 | 39 | 13.45 | 1096 | 575 | 4.14 / 663.63 | 2 | 2 |
7 | 8 | 0.16 | 180 | 14.14 | 305 | 776 | 4.92 / 664.40 | 2 | 4 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 27 | 14.20 | 448 | 172 | 0.17 / 654.59 | 2 | 2 |
2 | 12 | 1120.88 | 5 | 11.96 | 1892 | 113 | 0.28 / 654.70 | 2 | 2 |
3 | 12 | 2002.64 | 42 | 10.53 | 3081 | 1363 | 1.65 / 656.06 | 2 | 2 |
4 | 7 | 1997.12 | 22 | 11.33 | 3096 | 772 | 2.42 / 656.84 | 2 | 2 |
5 | 13 | 1431.00 | 39 | 12.48 | 2359 | 1148 | 3.57 / 657.98 | 2 | 2 |
6 | 13 | 506.36 | 39 | 13.49 | 1051 | 553 | 4.12 / 658.54 | 2 | 2 |
7 | 13 | 7.92 | 39 | 14.22 | 316 | 175 | 4.30 / 658.71 | 2 | 2 |
8 | 8 | -0.04 | 180 | 14.09 | 306 | 776 | 5.07 / 659.49 | 2 | 5 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 27 | 14.20 | 452 | 173 | 0.17 / 649.51 | 2 | 2 |
2 | 12 | 1123.20 | 5 | 12.00 | 1897 | 114 | 0.29 / 649.63 | 2 | 2 |
3 | 12 | 2003.60 | 42 | 10.54 | 3086 | 1366 | 1.65 / 650.99 | 2 | 2 |
4 | 7 | 1998.00 | 22 | 11.31 | 3084 | 767 | 2.42 / 651.76 | 2 | 2 |
5 | 13 | 1581.92 | 39 | 12.33 | 2544 | 1223 | 3.64 / 652.99 | 2 | 2 |
6 | 13 | 652.60 | 39 | 13.31 | 1258 | 653 | 4.30 / 653.64 | 2 | 2 |
7 | 8 | -0.04 | 180 | 14.12 | 306 | 778 | 5.07 / 654.42 | 2 | 3 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 28 | 14.20 | 449 | 179 | 0.18 / 644.45 | 2 | 2 |
2 | 3 | 961.20 | -1 | 14.20 | 449 | 0 | 0.00 / 644.45 | 2 | 2 |
3 | 12 | 1131.56 | 5 | 11.87 | 1906 | 113 | 0.29 / 644.56 | 2 | 2 |
4 | 12 | 2000.52 | 42 | 10.52 | 3103 | 1371 | 1.66 / 645.93 | 2 | 2 |
5 | 7 | 1994.92 | 23 | 11.30 | 3094 | 804 | 2.47 / 646.74 | 2 | 2 |
6 | 13 | 1555.00 | 39 | 12.35 | 2497 | 1203 | 3.67 / 647.94 | 2 | 2 |
7 | 13 | 603.08 | 39 | 13.37 | 1185 | 618 | 4.29 / 648.56 | 2 | 2 |
8 | 8 | -0.24 | 180 | 14.11 | 308 | 782 | 5.07 / 649.34 | 2 | 3 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 28 | 14.22 | 454 | 181 | 0.18 / 639.50 | 2 | 2 |
2 | 3 | 1029.68 | 1 | 12.43 | 1801 | 22 | 0.20 / 639.52 | 2 | 2 |
3 | 12 | 1130.68 | 5 | 11.89 | 1916 | 114 | 0.32 / 639.63 | 2 | 2 |
4 | 12 | 2001.64 | 42 | 10.52 | 3095 | 1367 | 1.68 / 641.00 | 2 | 2 |
5 | 7 | 1995.76 | 22 | 11.32 | 3097 | 771 | 2.46 / 641.77 | 2 | 2 |
6 | 13 | 1573.32 | 39 | 12.33 | 2524 | 1214 | 3.67 / 642.99 | 2 | 2 |
7 | 13 | 493.84 | 39 | 13.50 | 1014 | 534 | 4.20 / 643.52 | 2 | 2 |
8 | 8 | 0.20 | 180 | 14.13 | 296 | 753 | 4.96 / 644.27 | 2 | 7 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 27 | 14.24 | 439 | 169 | 0.17 / 634.61 | 2 | 2 |
2 | 12 | 1129.16 | 5 | 11.98 | 1908 | 114 | 0.28 / 634.73 | 2 | 2 |
3 | 12 | 2002.40 | 42 | 10.58 | 3099 | 1377 | 1.66 / 636.10 | 2 | 2 |
4 | 7 | 1996.44 | 22 | 11.32 | 3093 | 770 | 2.43 / 636.87 | 2 | 2 |
5 | 13 | 1441.16 | 39 | 12.45 | 2352 | 1142 | 3.57 / 638.02 | 2 | 2 |
6 | 13 | 506.60 | 39 | 13.49 | 1032 | 543 | 4.12 / 638.56 | 2 | 2 |
7 | 8 | 0.08 | 180 | 14.12 | 298 | 757 | 4.87 / 639.32 | 2 | 3 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 28 | 14.26 | 435 | 174 | 0.17 / 629.79 | 2 | 2 |
2 | 3 | 973.40 | -1 | 14.26 | 435 | 0 | 0.00 / 629.79 | 2 | 2 |
3 | 3 | 1034.96 | 1 | 12.30 | 1794 | 22 | 0.20 / 629.81 | 2 | 2 |
4 | 12 | 1129.60 | 5 | 11.93 | 1908 | 114 | 0.31 / 629.93 | 2 | 2 |
5 | 12 | 2001.08 | 42 | 10.59 | 3091 | 1375 | 1.68 / 631.30 | 2 | 2 |
6 | 7 | 1995.60 | 22 | 11.33 | 3087 | 769 | 2.45 / 632.07 | 2 | 2 |
7 | 13 | 1447.44 | 39 | 12.44 | 2364 | 1147 | 3.60 / 633.22 | 2 | 2 |
8 | 13 | 397.92 | 39 | 13.62 | 875 | 465 | 4.07 / 633.68 | 2 | 2 |
9 | 8 | -0.20 | 180 | 14.13 | 299 | 760 | 4.83 / 634.44 | 2 | 2 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 28 | 14.23 | 442 | 176 | 0.18 / 624.78 | 2 | 2 |
2 | 12 | 1119.44 | 5 | 11.92 | 1899 | 113 | 0.29 / 624.89 | 2 | 2 |
3 | 12 | 2000.84 | 42 | 10.57 | 3085 | 1370 | 1.66 / 626.26 | 2 | 2 |
4 | 7 | 1995.24 | 22 | 11.30 | 3082 | 766 | 2.43 / 627.03 | 2 | 2 |
5 | 13 | 1576.96 | 39 | 12.33 | 2515 | 1209 | 3.63 / 628.24 | 2 | 2 |
6 | 13 | 387.64 | 39 | 13.64 | 860 | 457 | 4.09 / 628.69 | 2 | 2 |
7 | 13 | 4.64 | 39 | 14.24 | 293 | 163 | 4.25 / 628.86 | 2 | 2 |
8 | 8 | -0.20 | 180 | 14.09 | 300 | 761 | 5.02 / 629.62 | 2 | 12 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 27 | 14.23 | 433 | 166 | 0.17 / 619.88 | 2 | 2 |
2 | 12 | 1135.36 | 5 | 12.00 | 1934 | 116 | 0.28 / 619.99 | 2 | 2 |
3 | 12 | 2002.16 | 42 | 10.63 | 3111 | 1389 | 1.67 / 621.38 | 2 | 2 |
4 | 7 | 1996.56 | 22 | 11.33 | 3081 | 768 | 2.44 / 622.15 | 2 | 2 |
5 | 13 | 1438.24 | 39 | 12.46 | 2349 | 1141 | 3.58 / 623.29 | 2 | 2 |
6 | 13 | 523.16 | 39 | 13.48 | 1052 | 553 | 4.13 / 623.84 | 2 | 2 |
7 | 8 | -0.12 | 180 | 14.14 | 298 | 758 | 4.89 / 624.60 | 2 | 3 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 27 | 14.23 | 449 | 173 | 0.17 / 614.92 | 2 | 2 |
2 | 12 | 1125.80 | 5 | 11.95 | 1906 | 114 | 0.29 / 615.04 | 2 | 2 |
3 | 12 | 1999.52 | 36 | 10.79 | 3093 | 1201 | 1.49 / 616.24 | 2 | 2 |
4 | 7 | 1994.16 | 22 | 11.34 | 3091 | 771 | 2.26 / 617.01 | 2 | 2 |
5 | 13 | 1720.04 | 39 | 12.17 | 2720 | 1291 | 3.55 / 618.30 | 2 | 2 |
6 | 13 | 653.28 | 39 | 13.32 | 1239 | 644 | 4.19 / 618.94 | 2 | 2 |
7 | 8 | -0.12 | 180 | 14.12 | 301 | 765 | 4.96 / 619.71 | 2 | 2 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 27 | 14.20 | 452 | 173 | 0.17 / 609.68 | 2 | 2 |
2 | 3 | 965.92 | -1 | 14.20 | 452 | 0 | 0.00 / 609.68 | 2 | 2 |
3 | 3 | 1026.40 | 1 | 11.64 | 1812 | 21 | 0.19 / 609.70 | 2 | 2 |
4 | 12 | 1124.84 | 5 | 12.06 | 1902 | 115 | 0.31 / 609.81 | 2 | 2 |
5 | 12 | 2006.16 | 36 | 10.67 | 3117 | 1197 | 1.51 / 611.01 | 2 | 2 |
6 | 7 | 2000.76 | 22 | 11.38 | 3108 | 778 | 2.28 / 611.79 | 2 | 2 |
7 | 13 | 1729.44 | 39 | 12.15 | 2735 | 1296 | 3.58 / 613.09 | 2 | 2 |
8 | 13 | 801.68 | 39 | 13.16 | 1443 | 741 | 4.32 / 613.83 | 2 | 2 |
9 | 13 | 2.88 | 39 | 14.26 | 285 | 158 | 4.48 / 613.98 | 2 | 2 |
10 | 8 | -0.20 | 180 | 14.09 | 302 | 766 | 5.25 / 614.75 | 2 | 3 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 27 | 14.22 | 443 | 170 | 0.17 / 604.52 | 2 | 2 |
2 | 12 | 1123.44 | 5 | 12.02 | 1904 | 114 | 0.28 / 604.64 | 2 | 2 |
3 | 12 | 2003.96 | 36 | 10.73 | 3098 | 1197 | 1.48 / 605.83 | 2 | 2 |
4 | 7 | 1998.60 | 22 | 11.33 | 3096 | 772 | 2.25 / 606.60 | 2 | 2 |
5 | 13 | 1727.28 | 39 | 12.14 | 2734 | 1294 | 3.55 / 607.90 | 2 | 2 |
6 | 13 | 651.48 | 39 | 13.31 | 1248 | 648 | 4.20 / 608.55 | 2 | 2 |
7 | 13 | 16.76 | 39 | 14.18 | 331 | 183 | 4.38 / 608.73 | 2 | 2 |
8 | 8 | -0.12 | 180 | 14.04 | 307 | 776 | 5.15 / 609.50 | 2 | 5 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 29 | 14.20 | 446 | 184 | 0.18 / 599.47 | 2 | 2 |
2 | 3 | 954.24 | -1 | 14.20 | 446 | 0 | 0.00 / 599.47 | 2 | 2 |
3 | 12 | 1117.12 | 5 | 12.05 | 1892 | 114 | 0.30 / 599.58 | 2 | 2 |
4 | 12 | 2001.24 | 30 | 10.91 | 3087 | 1010 | 1.31 / 600.59 | 2 | 2 |
5 | 7 | 1996.28 | 22 | 11.42 | 3092 | 777 | 2.08 / 601.37 | 2 | 2 |
6 | 13 | 1728.80 | 39 | 12.14 | 2730 | 1293 | 3.38 / 602.66 | 2 | 2 |
7 | 13 | 809.40 | 39 | 13.13 | 1467 | 751 | 4.13 / 603.41 | 2 | 2 |
8 | 13 | 2.84 | 39 | 14.22 | 309 | 171 | 4.30 / 603.59 | 2 | 2 |
9 | 8 | 0.08 | 180 | 14.08 | 302 | 765 | 5.07 / 604.35 | 2 | 5 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 27 | 14.21 | 457 | 175 | 0.18 / 594.45 | 2 | 2 |
2 | 10 | 1002.84 | 3 | 13.08 | 1751 | 69 | 0.24 / 594.52 | 2 | 2 |
3 | 3 | 953.68 | -1 | 13.08 | 1751 | 0 | 0.07 / 594.52 | 2 | 2 |
4 | 12 | 1124.32 | 5 | 11.95 | 1900 | 114 | 0.36 / 594.64 | 2 | 2 |
5 | 12 | 1999.96 | 30 | 10.88 | 3095 | 1010 | 1.37 / 595.65 | 2 | 2 |
6 | 7 | 1995.44 | 22 | 11.47 | 3087 | 779 | 2.15 / 596.42 | 2 | 2 |
7 | 13 | 1867.72 | 39 | 11.99 | 2917 | 1364 | 3.51 / 597.79 | 2 | 2 |
8 | 13 | 801.92 | 39 | 13.15 | 1447 | 742 | 4.25 / 598.53 | 2 | 2 |
9 | 8 | -0.28 | 180 | 14.11 | 297 | 754 | 5.01 / 599.29 | 2 | 4 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 27 | 14.24 | 440 | 169 | 0.17 / 589.64 | 2 | 2 |
2 | 12 | 1107.84 | 5 | 12.07 | 1879 | 113 | 0.28 / 589.75 | 2 | 2 |
3 | 12 | 2001.96 | 30 | 10.76 | 3135 | 1012 | 1.29 / 590.76 | 2 | 2 |
4 | 7 | 1997.00 | 22 | 11.43 | 3091 | 777 | 2.07 / 591.54 | 2 | 2 |
5 | 13 | 1735.48 | 39 | 12.13 | 2749 | 1300 | 3.37 / 592.84 | 2 | 2 |
6 | 13 | 671.20 | 39 | 13.28 | 1284 | 665 | 4.04 / 593.51 | 2 | 2 |
7 | 8 | 0.04 | 180 | 14.11 | 304 | 772 | 4.81 / 594.28 | 2 | 3 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 27 | 14.23 | 439 | 169 | 0.17 / 584.50 | 2 | 2 |
2 | 12 | 1110.80 | 5 | 12.01 | 1892 | 114 | 0.28 / 584.61 | 2 | 2 |
3 | 12 | 2001.28 | 30 | 10.95 | 3094 | 1016 | 1.30 / 585.63 | 2 | 2 |
4 | 7 | 1996.80 | 22 | 11.41 | 3090 | 776 | 2.07 / 586.41 | 2 | 2 |
5 | 13 | 1864.20 | 39 | 11.98 | 2916 | 1362 | 3.44 / 587.77 | 2 | 2 |
6 | 13 | 792.80 | 39 | 13.15 | 1450 | 744 | 4.18 / 588.51 | 2 | 2 |
7 | 13 | 17.40 | 39 | 14.19 | 330 | 183 | 4.36 / 588.70 | 2 | 2 |
8 | 8 | -0.20 | 180 | 14.04 | 306 | 773 | 5.14 / 589.47 | 2 | 3 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 27 | 14.22 | 446 | 171 | 0.17 / 579.49 | 2 | 2 |
2 | 12 | 1125.92 | 5 | 12.02 | 1898 | 114 | 0.29 / 579.61 | 2 | 2 |
3 | 12 | 2000.16 | 30 | 10.93 | 3126 | 1025 | 1.31 / 580.63 | 2 | 2 |
4 | 7 | 1996.04 | 22 | 11.44 | 3100 | 780 | 2.09 / 581.41 | 2 | 2 |
5 | 13 | 1729.08 | 39 | 12.16 | 2740 | 1299 | 3.39 / 582.71 | 2 | 2 |
6 | 13 | 960.52 | 39 | 12.98 | 1678 | 849 | 4.24 / 583.56 | 2 | 2 |
7 | 8 | -0.12 | 180 | 14.12 | 303 | 770 | 5.01 / 584.33 | 2 | 2 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 28 | 14.21 | 448 | 178 | 0.18 / 574.59 | 2 | 2 |
2 | 3 | 956.68 | -1 | 14.21 | 448 | 0 | 0.00 / 574.59 | 2 | 2 |
3 | 12 | 1135.08 | 5 | 12.11 | 1922 | 116 | 0.29 / 574.70 | 2 | 2 |
4 | 12 | 2001.00 | 30 | 10.96 | 3103 | 1020 | 1.31 / 575.72 | 2 | 2 |
5 | 7 | 1996.20 | 22 | 11.43 | 3099 | 779 | 2.09 / 576.50 | 2 | 2 |
6 | 13 | 1732.96 | 39 | 12.13 | 2746 | 1299 | 3.39 / 577.80 | 2 | 2 |
7 | 13 | 826.16 | 39 | 13.13 | 1478 | 757 | 4.15 / 578.56 | 2 | 2 |
8 | 8 | -0.08 | 180 | 14.09 | 301 | 763 | 4.91 / 579.32 | 2 | 2 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 27 | 14.17 | 471 | 180 | 0.18 / 569.77 | 2 | 2 |
2 | 3 | 1024.68 | 1 | 11.97 | 1811 | 22 | 0.20 / 569.80 | 2 | 2 |
3 | 12 | 1122.24 | 5 | 12.12 | 1906 | 116 | 0.32 / 569.91 | 2 | 2 |
4 | 12 | 1999.68 | 30 | 10.79 | 3124 | 1011 | 1.33 / 570.92 | 2 | 2 |
5 | 7 | 1994.44 | 22 | 11.44 | 3099 | 780 | 2.11 / 571.70 | 2 | 2 |
6 | 13 | 1728.00 | 39 | 12.16 | 2741 | 1300 | 3.41 / 573.00 | 2 | 2 |
7 | 13 | 691.84 | 39 | 13.27 | 1299 | 672 | 4.08 / 573.67 | 2 | 2 |
8 | 8 | 0.08 | 180 | 14.13 | 289 | 735 | 4.82 / 574.41 | 2 | 4 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 27 | 14.19 | 450 | 172 | 0.17 / 564.89 | 2 | 2 |
2 | 3 | 956.64 | -1 | 14.19 | 450 | 0 | 0.00 / 564.89 | 2 | 2 |
3 | 12 | 1127.52 | 5 | 12.08 | 1918 | 116 | 0.29 / 565.00 | 2 | 2 |
4 | 12 | 2002.24 | 30 | 10.80 | 3144 | 1019 | 1.31 / 566.02 | 2 | 2 |
5 | 7 | 1997.56 | 22 | 11.41 | 3097 | 777 | 2.08 / 566.80 | 2 | 2 |
6 | 13 | 1736.80 | 39 | 12.15 | 2742 | 1299 | 3.38 / 568.10 | 2 | 2 |
7 | 13 | 806.52 | 39 | 13.14 | 1453 | 745 | 4.13 / 568.84 | 2 | 2 |
8 | 8 | 0.00 | 180 | 14.10 | 295 | 749 | 4.88 / 569.59 | 2 | 3 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 26 | 14.19 | 469 | 173 | 0.17 / 559.90 | 2 | 2 |
2 | 3 | 1031.96 | 1 | 12.34 | 1808 | 22 | 0.20 / 559.93 | 2 | 2 |
3 | 3 | 1020.44 | 1 | 12.13 | 1812 | 22 | 0.22 / 559.95 | 2 | 2 |
4 | 12 | 1126.88 | 5 | 12.05 | 1915 | 115 | 0.33 / 560.06 | 2 | 2 |
5 | 12 | 2002.00 | 30 | 10.81 | 3146 | 1020 | 1.35 / 561.08 | 2 | 2 |
6 | 7 | 1997.52 | 22 | 11.44 | 3100 | 780 | 2.13 / 561.86 | 2 | 2 |
7 | 13 | 1873.36 | 39 | 11.97 | 2932 | 1369 | 3.50 / 563.23 | 2 | 2 |
8 | 13 | 815.64 | 39 | 13.12 | 1469 | 752 | 4.25 / 563.99 | 2 | 2 |
9 | 8 | -0.04 | 180 | 14.11 | 288 | 731 | 4.99 / 564.72 | 2 | 3 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 27 | 14.18 | 454 | 174 | 0.17 / 555.14 | 2 | 2 |
2 | 3 | 960.76 | -1 | 14.18 | 454 | 0 | 0.00 / 555.14 | 2 | 2 |
3 | 12 | 1123.08 | 5 | 12.10 | 1915 | 116 | 0.29 / 555.26 | 2 | 2 |
4 | 12 | 2000.80 | 30 | 11.01 | 3103 | 1025 | 1.31 / 556.28 | 2 | 2 |
5 | 7 | 1996.20 | 22 | 11.42 | 3105 | 780 | 2.09 / 557.06 | 2 | 2 |
6 | 13 | 1600.56 | 39 | 12.26 | 2563 | 1225 | 3.32 / 558.29 | 2 | 2 |
7 | 13 | 703.48 | 39 | 13.24 | 1317 | 680 | 4.00 / 558.97 | 2 | 2 |
8 | 8 | -0.12 | 180 | 14.09 | 301 | 763 | 4.76 / 559.73 | 2 | 4 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 27 | 14.18 | 464 | 178 | 0.18 / 550.29 | 2 | 2 |
2 | 12 | 1115.08 | 5 | 12.13 | 1903 | 115 | 0.29 / 550.41 | 2 | 2 |
3 | 12 | 2002.08 | 30 | 10.97 | 3107 | 1023 | 1.32 / 551.43 | 2 | 2 |
4 | 7 | 1997.32 | 22 | 11.37 | 3105 | 777 | 2.09 / 552.20 | 2 | 2 |
5 | 13 | 1739.44 | 39 | 12.12 | 2756 | 1303 | 3.39 / 553.51 | 2 | 2 |
6 | 13 | 695.36 | 39 | 13.24 | 1309 | 676 | 4.07 / 554.18 | 2 | 2 |
7 | 8 | 0.08 | 180 | 14.07 | 310 | 785 | 4.86 / 554.97 | 2 | 3 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 27 | 14.19 | 466 | 179 | 0.18 / 545.40 | 2 | 2 |
2 | 12 | 1121.92 | 5 | 12.13 | 1916 | 116 | 0.29 / 545.51 | 2 | 2 |
3 | 12 | 2000.52 | 30 | 10.98 | 3105 | 1023 | 1.32 / 546.53 | 2 | 2 |
4 | 7 | 1995.32 | 22 | 11.42 | 3095 | 778 | 2.10 / 547.31 | 2 | 2 |
5 | 13 | 1715.96 | 39 | 12.14 | 2727 | 1291 | 3.39 / 548.60 | 2 | 2 |
6 | 13 | 808.48 | 39 | 13.12 | 1462 | 748 | 4.13 / 549.35 | 2 | 2 |
7 | 8 | -0.04 | 180 | 14.08 | 300 | 760 | 4.89 / 550.11 | 2 | 2 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 27 | 14.22 | 449 | 172 | 0.17 / 540.61 | 2 | 2 |
2 | 3 | 967.40 | -1 | 14.22 | 449 | 0 | 0.00 / 540.61 | 2 | 2 |
3 | 3 | 1021.64 | 1 | 10.83 | 1793 | 19 | 0.19 / 540.62 | 2 | 2 |
4 | 12 | 1141.44 | 5 | 12.20 | 1938 | 118 | 0.31 / 540.74 | 2 | 2 |
5 | 12 | 2002.40 | 30 | 11.07 | 3103 | 1031 | 1.34 / 541.77 | 2 | 2 |
6 | 7 | 1997.76 | 22 | 11.42 | 3101 | 779 | 2.12 / 542.55 | 2 | 2 |
7 | 13 | 1604.32 | 39 | 12.25 | 2568 | 1227 | 3.35 / 543.78 | 2 | 2 |
8 | 13 | 678.84 | 39 | 13.26 | 1283 | 663 | 4.01 / 544.44 | 2 | 2 |
9 | 8 | 0.08 | 180 | 14.06 | 306 | 774 | 4.78 / 545.22 | 2 | 3 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 27 | 14.20 | 456 | 175 | 0.17 / 535.48 | 2 | 2 |
2 | 12 | 1098.24 | 5 | 12.14 | 1892 | 115 | 0.29 / 535.59 | 2 | 2 |
3 | 12 | 2000.32 | 30 | 10.90 | 3104 | 1015 | 1.30 / 536.61 | 2 | 2 |
4 | 7 | 1995.80 | 22 | 11.36 | 3105 | 776 | 2.08 / 537.38 | 2 | 2 |
5 | 13 | 1862.24 | 39 | 11.91 | 2919 | 1356 | 3.44 / 538.74 | 2 | 2 |
6 | 13 | 795.84 | 39 | 13.12 | 1456 | 745 | 4.18 / 539.48 | 2 | 2 |
7 | 13 | 1.84 | 39 | 14.21 | 313 | 173 | 4.35 / 539.66 | 2 | 2 |
8 | 8 | -0.08 | 180 | 14.02 | 308 | 777 | 5.13 / 540.43 | 2 | 6 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 27 | 14.19 | 455 | 174 | 0.17 / 530.57 | 2 | 2 |
2 | 12 | 1100.76 | 5 | 12.10 | 1873 | 113 | 0.29 / 530.69 | 2 | 2 |
3 | 12 | 2001.92 | 30 | 10.78 | 3131 | 1013 | 1.30 / 531.70 | 2 | 2 |
4 | 7 | 1997.08 | 22 | 11.39 | 3094 | 775 | 2.08 / 532.47 | 2 | 2 |
5 | 13 | 1727.64 | 39 | 12.10 | 2737 | 1292 | 3.37 / 533.77 | 2 | 2 |
6 | 13 | 804.28 | 39 | 13.11 | 1476 | 755 | 4.12 / 534.52 | 2 | 2 |
7 | 8 | 0.08 | 180 | 14.07 | 308 | 780 | 4.90 / 535.30 | 2 | 4 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 27 | 14.19 | 455 | 174 | 0.17 / 525.67 | 2 | 2 |
2 | 3 | 1019.16 | 1 | 11.02 | 1806 | 20 | 0.19 / 525.69 | 2 | 2 |
3 | 12 | 1125.08 | 5 | 12.07 | 1920 | 116 | 0.31 / 525.81 | 2 | 2 |
4 | 12 | 2003.28 | 30 | 11.06 | 3101 | 1029 | 1.34 / 526.84 | 2 | 2 |
5 | 7 | 1998.84 | 22 | 11.41 | 3098 | 778 | 2.12 / 527.61 | 2 | 2 |
6 | 13 | 1729.84 | 39 | 12.10 | 2736 | 1291 | 3.41 / 528.90 | 2 | 2 |
7 | 13 | 820.68 | 39 | 13.10 | 1485 | 759 | 4.17 / 529.66 | 2 | 2 |
8 | 8 | 0.12 | 180 | 14.10 | 290 | 736 | 4.90 / 530.40 | 2 | 3 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 27 | 14.22 | 454 | 174 | 0.17 / 520.77 | 2 | 2 |
2 | 12 | 1104.28 | 5 | 12.22 | 1886 | 115 | 0.29 / 520.88 | 2 | 2 |
3 | 12 | 1999.76 | 30 | 11.03 | 3094 | 1024 | 1.31 / 521.91 | 2 | 2 |
4 | 7 | 1994.92 | 22 | 11.39 | 3088 | 774 | 2.09 / 522.68 | 2 | 2 |
5 | 13 | 1723.88 | 39 | 12.10 | 2724 | 1285 | 3.37 / 523.97 | 2 | 2 |
6 | 13 | 816.96 | 39 | 13.08 | 1478 | 754 | 4.13 / 524.72 | 2 | 2 |
7 | 8 | -0.04 | 180 | 14.07 | 307 | 778 | 4.90 / 525.50 | 2 | 4 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 26 | 14.20 | 462 | 171 | 0.17 / 515.81 | 2 | 2 |
2 | 12 | 1133.00 | 5 | 12.18 | 1926 | 117 | 0.29 / 515.92 | 2 | 2 |
3 | 12 | 2001.44 | 30 | 11.14 | 3116 | 1041 | 1.33 / 516.96 | 2 | 2 |
4 | 7 | 1996.68 | 22 | 11.42 | 3101 | 779 | 2.11 / 517.74 | 2 | 2 |
5 | 13 | 1863.04 | 39 | 11.92 | 2923 | 1359 | 3.47 / 519.10 | 2 | 2 |
6 | 13 | 773.12 | 39 | 13.14 | 1419 | 727 | 4.19 / 519.83 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.09 | 301 | 763 | 4.96 / 520.59 | 2 | 2 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 27 | 14.19 | 450 | 172 | 0.17 / 510.66 | 2 | 2 |
2 | 3 | 972.28 | -1 | 14.19 | 450 | 0 | 0.00 / 510.66 | 2 | 2 |
3 | 3 | 1021.20 | 1 | 10.72 | 1789 | 19 | 0.19 / 510.68 | 2 | 2 |
4 | 12 | 1123.60 | 5 | 12.14 | 1936 | 118 | 0.31 / 510.80 | 2 | 2 |
5 | 12 | 2003.72 | 30 | 11.09 | 3113 | 1036 | 1.34 / 511.83 | 2 | 2 |
6 | 7 | 1999.36 | 22 | 11.43 | 3105 | 781 | 2.13 / 512.62 | 2 | 2 |
7 | 13 | 1873.44 | 39 | 11.91 | 2931 | 1361 | 3.49 / 513.98 | 2 | 2 |
8 | 13 | 788.60 | 39 | 13.12 | 1436 | 735 | 4.22 / 514.71 | 2 | 2 |
9 | 13 | 2.16 | 39 | 14.22 | 299 | 166 | 4.39 / 514.88 | 2 | 2 |
10 | 8 | 0.00 | 180 | 14.02 | 300 | 757 | 5.14 / 515.63 | 2 | 3 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 27 | 14.21 | 459 | 176 | 0.18 / 505.83 | 2 | 2 |
2 | 12 | 1118.32 | 5 | 12.20 | 1920 | 117 | 0.29 / 505.95 | 2 | 2 |
3 | 12 | 2000.32 | 30 | 11.10 | 3110 | 1036 | 1.33 / 506.98 | 2 | 2 |
4 | 7 | 1995.80 | 22 | 11.38 | 3097 | 775 | 2.10 / 507.76 | 2 | 2 |
5 | 13 | 1726.16 | 39 | 12.07 | 2747 | 1293 | 3.40 / 509.05 | 2 | 2 |
6 | 13 | 686.24 | 39 | 13.23 | 1299 | 670 | 4.07 / 509.72 | 2 | 2 |
7 | 8 | -0.12 | 180 | 14.08 | 303 | 768 | 4.84 / 510.49 | 2 | 3 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 27 | 14.21 | 469 | 180 | 0.18 / 500.86 | 2 | 2 |
2 | 12 | 1115.04 | 5 | 12.12 | 1912 | 116 | 0.30 / 500.98 | 2 | 2 |
3 | 12 | 2002.12 | 30 | 11.10 | 3109 | 1035 | 1.33 / 502.02 | 2 | 2 |
4 | 7 | 1997.84 | 22 | 11.43 | 3105 | 781 | 2.11 / 502.80 | 2 | 2 |
5 | 13 | 1864.76 | 39 | 11.91 | 2917 | 1355 | 3.47 / 504.15 | 2 | 2 |
6 | 13 | 758.44 | 39 | 13.14 | 1413 | 724 | 4.19 / 504.88 | 2 | 2 |
7 | 8 | 0.20 | 180 | 14.06 | 308 | 779 | 4.97 / 505.65 | 2 | 3 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 27 | 14.21 | 452 | 173 | 0.17 / 495.97 | 2 | 2 |
2 | 12 | 1085.76 | 5 | 12.10 | 1868 | 113 | 0.29 / 496.08 | 2 | 2 |
3 | 12 | 2002.20 | 30 | 10.86 | 3133 | 1021 | 1.31 / 497.10 | 2 | 2 |
4 | 7 | 1997.32 | 22 | 11.40 | 3096 | 776 | 2.08 / 497.88 | 2 | 2 |
5 | 13 | 1720.60 | 39 | 12.11 | 2722 | 1286 | 3.37 / 499.16 | 2 | 2 |
6 | 13 | 801.80 | 39 | 13.11 | 1457 | 745 | 4.11 / 499.91 | 2 | 2 |
7 | 8 | 0.12 | 180 | 14.06 | 306 | 774 | 4.89 / 500.68 | 2 | 2 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 27 | 14.25 | 436 | 168 | 0.17 / 491.05 | 2 | 2 |
2 | 12 | 1101.24 | 5 | 12.16 | 1874 | 114 | 0.28 / 491.16 | 2 | 2 |
3 | 12 | 2001.00 | 30 | 11.07 | 3098 | 1029 | 1.31 / 492.19 | 2 | 2 |
4 | 7 | 1996.24 | 22 | 11.39 | 3084 | 773 | 2.08 / 492.96 | 2 | 2 |
5 | 13 | 1605.12 | 39 | 12.23 | 2566 | 1224 | 3.31 / 494.19 | 2 | 2 |
6 | 13 | 720.80 | 39 | 13.21 | 1343 | 692 | 4.00 / 494.88 | 2 | 2 |
7 | 13 | 20.20 | 39 | 14.19 | 320 | 177 | 4.18 / 495.06 | 2 | 2 |
8 | 8 | 0.00 | 180 | 14.02 | 293 | 739 | 4.92 / 495.80 | 2 | 10 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 27 | 14.26 | 432 | 166 | 0.17 / 486.17 | 2 | 2 |
2 | 12 | 1140.08 | 5 | 12.20 | 1933 | 118 | 0.28 / 486.29 | 2 | 2 |
3 | 12 | 1999.88 | 30 | 11.18 | 3095 | 1038 | 1.32 / 487.33 | 2 | 2 |
4 | 7 | 1994.64 | 22 | 11.41 | 3100 | 778 | 2.10 / 488.11 | 2 | 2 |
5 | 13 | 1724.24 | 39 | 12.11 | 2724 | 1287 | 3.39 / 489.39 | 2 | 2 |
6 | 13 | 796.20 | 39 | 13.11 | 1452 | 742 | 4.13 / 490.14 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.09 | 293 | 743 | 4.87 / 490.88 | 2 | 3 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 27 | 14.28 | 432 | 167 | 0.17 / 481.25 | 2 | 2 |
2 | 12 | 1124.04 | 5 | 12.08 | 1927 | 116 | 0.28 / 481.36 | 2 | 2 |
3 | 12 | 2003.20 | 30 | 10.87 | 3135 | 1022 | 1.31 / 482.39 | 2 | 2 |
4 | 7 | 1998.72 | 22 | 11.42 | 3095 | 778 | 2.08 / 483.16 | 2 | 2 |
5 | 13 | 1864.84 | 39 | 11.91 | 2919 | 1356 | 3.44 / 484.52 | 2 | 2 |
6 | 13 | 805.80 | 39 | 13.11 | 1465 | 749 | 4.19 / 485.27 | 2 | 2 |
7 | 8 | -0.12 | 180 | 14.11 | 291 | 739 | 4.93 / 486.01 | 2 | 3 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 27 | 14.27 | 434 | 167 | 0.17 / 476.40 | 2 | 2 |
2 | 12 | 1112.44 | 5 | 12.13 | 1905 | 116 | 0.28 / 476.52 | 2 | 2 |
3 | 12 | 2003.52 | 30 | 11.14 | 3114 | 1041 | 1.32 / 477.56 | 2 | 2 |
4 | 7 | 1998.72 | 22 | 11.44 | 3111 | 783 | 2.11 / 478.34 | 2 | 2 |
5 | 13 | 1601.08 | 39 | 12.24 | 2568 | 1226 | 3.33 / 479.57 | 2 | 2 |
6 | 13 | 832.80 | 39 | 13.07 | 1506 | 768 | 4.10 / 480.33 | 2 | 2 |
7 | 8 | 0.20 | 180 | 14.10 | 294 | 746 | 4.85 / 481.08 | 2 | 3 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 27 | 14.28 | 427 | 165 | 0.16 / 471.18 | 2 | 2 |
2 | 3 | 961.08 | -1 | 14.28 | 427 | 0 | 0.00 / 471.18 | 2 | 2 |
3 | 12 | 1140.40 | 5 | 12.16 | 1943 | 118 | 0.28 / 471.30 | 2 | 2 |
4 | 12 | 2003.08 | 30 | 11.19 | 3111 | 1044 | 1.33 / 472.35 | 2 | 2 |
5 | 7 | 1998.68 | 22 | 11.46 | 3102 | 782 | 2.11 / 473.13 | 2 | 2 |
6 | 13 | 1864.00 | 39 | 11.93 | 2921 | 1359 | 3.47 / 474.49 | 2 | 2 |
7 | 13 | 923.96 | 39 | 12.98 | 1632 | 826 | 4.29 / 475.31 | 2 | 2 |
8 | 13 | 19.04 | 39 | 14.20 | 321 | 178 | 4.47 / 475.49 | 2 | 2 |
9 | 8 | -0.40 | 180 | 14.07 | 293 | 742 | 5.21 / 476.23 | 2 | 5 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 27 | 14.29 | 436 | 168 | 0.17 / 466.40 | 2 | 2 |
2 | 12 | 1133.24 | 5 | 12.13 | 1922 | 117 | 0.28 / 466.52 | 2 | 2 |
3 | 12 | 2001.76 | 30 | 10.92 | 3148 | 1031 | 1.32 / 467.55 | 2 | 2 |
4 | 7 | 1996.80 | 22 | 11.45 | 3091 | 779 | 2.09 / 468.33 | 2 | 2 |
5 | 13 | 1724.40 | 39 | 12.11 | 2728 | 1288 | 3.38 / 469.62 | 2 | 2 |
6 | 13 | 676.32 | 39 | 13.26 | 1286 | 665 | 4.05 / 470.28 | 2 | 2 |
7 | 8 | 0.04 | 180 | 14.10 | 290 | 736 | 4.78 / 471.02 | 2 | 3 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 27 | 14.28 | 438 | 169 | 0.17 / 461.64 | 2 | 2 |
2 | 12 | 1113.64 | 5 | 12.15 | 1923 | 117 | 0.29 / 461.76 | 2 | 2 |
3 | 12 | 2002.72 | 30 | 11.15 | 3115 | 1042 | 1.33 / 462.80 | 2 | 2 |
4 | 7 | 1998.16 | 22 | 11.47 | 3105 | 784 | 2.11 / 463.58 | 2 | 2 |
5 | 13 | 1598.84 | 39 | 12.27 | 2561 | 1226 | 3.34 / 464.81 | 2 | 2 |
6 | 13 | 705.88 | 39 | 13.23 | 1330 | 686 | 4.02 / 465.49 | 2 | 2 |
7 | 8 | -0.28 | 180 | 14.10 | 293 | 744 | 4.77 / 466.24 | 2 | 2 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 27 | 14.27 | 442 | 170 | 0.17 / 456.55 | 2 | 2 |
2 | 12 | 1106.20 | 5 | 12.08 | 1903 | 115 | 0.29 / 456.67 | 2 | 2 |
3 | 12 | 2001.20 | 30 | 10.93 | 3145 | 1031 | 1.32 / 457.70 | 2 | 2 |
4 | 7 | 1996.40 | 22 | 11.45 | 3107 | 783 | 2.10 / 458.48 | 2 | 2 |
5 | 13 | 1861.16 | 39 | 11.95 | 2916 | 1359 | 3.46 / 459.84 | 2 | 2 |
6 | 13 | 776.12 | 39 | 13.16 | 1424 | 731 | 4.19 / 460.57 | 2 | 2 |
7 | 13 | 5.84 | 39 | 14.25 | 297 | 165 | 4.35 / 460.74 | 2 | 2 |
8 | 8 | 0.04 | 180 | 14.06 | 290 | 734 | 5.09 / 461.47 | 2 | 5 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 27 | 14.29 | 442 | 171 | 0.17 / 451.55 | 2 | 2 |
2 | 12 | 1109.16 | 5 | 12.15 | 1888 | 115 | 0.29 / 451.66 | 2 | 2 |
3 | 12 | 2000.28 | 30 | 11.12 | 3111 | 1038 | 1.32 / 452.70 | 2 | 2 |
4 | 7 | 1994.96 | 22 | 11.50 | 3112 | 787 | 2.11 / 453.49 | 2 | 2 |
5 | 13 | 1719.36 | 39 | 12.14 | 2734 | 1294 | 3.40 / 454.78 | 2 | 2 |
6 | 13 | 946.20 | 39 | 12.97 | 1668 | 844 | 4.25 / 455.63 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.11 | 297 | 754 | 5.00 / 456.38 | 2 | 4 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 27 | 14.31 | 429 | 166 | 0.17 / 446.79 | 2 | 2 |
2 | 12 | 1116.20 | 5 | 12.09 | 1924 | 116 | 0.28 / 446.91 | 2 | 2 |
3 | 12 | 2001.12 | 30 | 11.13 | 3103 | 1036 | 1.32 / 447.94 | 2 | 2 |
4 | 7 | 1995.88 | 22 | 11.51 | 3106 | 787 | 2.10 / 448.73 | 2 | 2 |
5 | 13 | 1582.92 | 39 | 12.28 | 2561 | 1227 | 3.33 / 449.96 | 2 | 2 |
6 | 13 | 686.64 | 39 | 13.26 | 1305 | 675 | 4.01 / 450.63 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.10 | 294 | 746 | 4.75 / 451.38 | 2 | 7 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 27 | 14.29 | 446 | 172 | 0.17 / 442.03 | 2 | 2 |
2 | 12 | 1133.92 | 5 | 12.05 | 1940 | 117 | 0.29 / 442.15 | 2 | 2 |
3 | 12 | 2000.56 | 30 | 11.09 | 3112 | 1035 | 1.32 / 443.18 | 2 | 2 |
4 | 7 | 1995.64 | 22 | 11.49 | 3103 | 784 | 2.11 / 443.97 | 2 | 2 |
5 | 13 | 1592.64 | 39 | 12.30 | 2566 | 1231 | 3.34 / 445.20 | 2 | 2 |
6 | 13 | 679.96 | 39 | 13.27 | 1297 | 671 | 4.01 / 445.87 | 2 | 2 |
7 | 8 | 0.04 | 180 | 14.11 | 298 | 757 | 4.77 / 446.63 | 2 | 4 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 27 | 14.28 | 444 | 171 | 0.17 / 437.27 | 2 | 2 |
2 | 12 | 1110.40 | 5 | 12.14 | 1905 | 116 | 0.29 / 437.39 | 2 | 2 |
3 | 12 | 1999.80 | 30 | 10.97 | 3145 | 1035 | 1.32 / 438.43 | 2 | 2 |
4 | 7 | 1994.80 | 22 | 11.54 | 3108 | 789 | 2.11 / 439.21 | 2 | 2 |
5 | 13 | 1461.36 | 39 | 12.43 | 2395 | 1161 | 3.27 / 440.38 | 2 | 2 |
6 | 13 | 715.16 | 39 | 13.25 | 1356 | 701 | 3.97 / 441.08 | 2 | 2 |
7 | 8 | -0.12 | 180 | 14.07 | 309 | 783 | 4.76 / 441.86 | 2 | 3 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 27 | 14.29 | 434 | 167 | 0.17 / 432.39 | 2 | 2 |
2 | 12 | 1105.40 | 5 | 12.07 | 1895 | 114 | 0.28 / 432.51 | 2 | 2 |
3 | 12 | 2001.60 | 30 | 11.00 | 3141 | 1037 | 1.32 / 433.55 | 2 | 2 |
4 | 7 | 1996.92 | 22 | 11.54 | 3109 | 789 | 2.11 / 434.33 | 2 | 2 |
5 | 13 | 1584.60 | 39 | 12.33 | 2546 | 1224 | 3.33 / 435.56 | 2 | 2 |
6 | 13 | 566.60 | 39 | 13.42 | 1132 | 592 | 3.92 / 436.15 | 2 | 2 |
7 | 13 | 32.80 | 39 | 14.18 | 349 | 193 | 4.12 / 436.34 | 2 | 2 |
8 | 8 | -0.08 | 180 | 14.06 | 300 | 759 | 4.88 / 437.10 | 2 | 4 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 27 | 14.30 | 436 | 168 | 0.17 / 427.37 | 2 | 2 |
2 | 12 | 1108.52 | 5 | 12.17 | 1910 | 116 | 0.28 / 427.48 | 2 | 2 |
3 | 12 | 2003.52 | 30 | 11.04 | 3152 | 1044 | 1.33 / 428.53 | 2 | 2 |
4 | 7 | 1999.00 | 22 | 11.58 | 3103 | 791 | 2.12 / 429.32 | 2 | 2 |
5 | 13 | 1593.24 | 39 | 12.33 | 2554 | 1228 | 3.35 / 430.55 | 2 | 2 |
6 | 13 | 817.44 | 39 | 13.14 | 1485 | 761 | 4.11 / 431.31 | 2 | 2 |
7 | 13 | 22.24 | 39 | 14.22 | 326 | 181 | 4.29 / 431.49 | 2 | 2 |
8 | 8 | -0.04 | 180 | 14.08 | 291 | 738 | 5.03 / 432.23 | 2 | 6 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 27 | 14.29 | 443 | 171 | 0.17 / 422.35 | 2 | 2 |
2 | 12 | 1118.72 | 5 | 12.11 | 1918 | 116 | 0.29 / 422.47 | 2 | 2 |
3 | 12 | 2001.76 | 30 | 11.14 | 3116 | 1041 | 1.33 / 423.51 | 2 | 2 |
4 | 7 | 1997.08 | 22 | 11.55 | 3102 | 788 | 2.12 / 424.30 | 2 | 2 |
5 | 13 | 1724.04 | 39 | 12.19 | 2745 | 1305 | 3.42 / 425.60 | 2 | 2 |
6 | 13 | 665.88 | 39 | 13.30 | 1278 | 663 | 4.08 / 426.27 | 2 | 2 |
7 | 13 | 22.20 | 39 | 14.20 | 334 | 185 | 4.27 / 426.45 | 2 | 2 |
8 | 8 | -0.32 | 180 | 14.05 | 296 | 749 | 5.02 / 427.20 | 2 | 9 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 27 | 14.30 | 436 | 168 | 0.17 / 417.54 | 2 | 2 |
2 | 12 | 1120.32 | 5 | 12.19 | 1917 | 117 | 0.29 / 417.66 | 2 | 2 |
3 | 12 | 2002.12 | 30 | 11.12 | 3130 | 1044 | 1.33 / 418.70 | 2 | 2 |
4 | 7 | 1997.04 | 22 | 11.58 | 3117 | 794 | 2.12 / 419.50 | 2 | 2 |
5 | 13 | 1595.64 | 39 | 12.33 | 2576 | 1239 | 3.36 / 420.74 | 2 | 2 |
6 | 13 | 697.28 | 39 | 13.28 | 1320 | 684 | 4.05 / 421.42 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.09 | 301 | 763 | 4.81 / 422.18 | 2 | 3 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 25 | 14.30 | 438 | 157 | 0.16 / 412.76 | 2 | 2 |
2 | 3 | 1032.12 | 1 | 12.50 | 1807 | 23 | 0.18 / 412.78 | 2 | 2 |
3 | 3 | 1020.44 | 1 | 12.42 | 1806 | 22 | 0.20 / 412.80 | 2 | 2 |
4 | 12 | 1129.16 | 5 | 12.19 | 1937 | 118 | 0.32 / 412.92 | 2 | 2 |
5 | 12 | 2000.64 | 30 | 11.11 | 3149 | 1050 | 1.37 / 413.97 | 2 | 2 |
6 | 7 | 1995.44 | 23 | 11.62 | 3115 | 833 | 2.20 / 414.80 | 2 | 2 |
7 | 13 | 1580.88 | 39 | 12.38 | 2548 | 1230 | 3.43 / 416.03 | 2 | 2 |
8 | 13 | 547.32 | 39 | 13.47 | 1106 | 581 | 4.01 / 416.61 | 2 | 2 |
9 | 8 | 0.04 | 180 | 14.09 | 300 | 761 | 4.77 / 417.37 | 2 | 3 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 26 | 14.29 | 438 | 163 | 0.16 / 407.83 | 2 | 2 |
2 | 3 | 957.08 | -1 | 14.29 | 438 | 0 | 0.00 / 407.83 | 2 | 2 |
3 | 12 | 1135.64 | 5 | 12.24 | 1950 | 119 | 0.28 / 407.94 | 2 | 2 |
4 | 12 | 2000.36 | 30 | 11.26 | 3116 | 1053 | 1.33 / 409.00 | 2 | 2 |
5 | 7 | 1995.24 | 22 | 11.65 | 3099 | 794 | 2.13 / 409.79 | 2 | 2 |
6 | 13 | 1718.24 | 39 | 12.21 | 2743 | 1306 | 3.44 / 411.10 | 2 | 2 |
7 | 13 | 785.88 | 39 | 13.19 | 1444 | 743 | 4.18 / 411.84 | 2 | 2 |
8 | 8 | -0.12 | 180 | 14.10 | 299 | 759 | 4.94 / 412.60 | 2 | 3 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 26 | 14.31 | 448 | 167 | 0.17 / 402.64 | 2 | 2 |
2 | 3 | 1023.48 | 1 | 11.99 | 1796 | 22 | 0.19 / 402.66 | 2 | 2 |
3 | 12 | 1139.24 | 5 | 12.20 | 1959 | 119 | 0.31 / 402.78 | 2 | 2 |
4 | 12 | 2000.84 | 30 | 11.25 | 3119 | 1053 | 1.36 / 403.83 | 2 | 2 |
5 | 7 | 1996.40 | 22 | 11.64 | 3102 | 794 | 2.15 / 404.63 | 2 | 2 |
6 | 13 | 1863.36 | 39 | 12.04 | 2934 | 1378 | 3.53 / 406.00 | 2 | 2 |
7 | 13 | 764.04 | 39 | 13.22 | 1416 | 730 | 4.26 / 406.73 | 2 | 2 |
8 | 13 | 7.36 | 39 | 14.24 | 314 | 174 | 4.44 / 406.91 | 2 | 2 |
9 | 8 | -0.24 | 180 | 14.02 | 299 | 755 | 5.19 / 407.66 | 2 | 3 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 26 | 14.30 | 440 | 164 | 0.16 / 397.75 | 2 | 2 |
2 | 3 | 967.32 | -1 | 14.30 | 440 | 0 | 0.00 / 397.75 | 2 | 2 |
3 | 3 | 1028.68 | 1 | 12.09 | 1810 | 22 | 0.19 / 397.77 | 2 | 2 |
4 | 12 | 1129.52 | 5 | 12.13 | 1935 | 117 | 0.30 / 397.89 | 2 | 2 |
5 | 12 | 2002.08 | 30 | 11.13 | 3134 | 1046 | 1.35 / 398.93 | 2 | 2 |
6 | 7 | 1997.40 | 22 | 11.64 | 3114 | 797 | 2.15 / 399.73 | 2 | 2 |
7 | 13 | 1582.12 | 39 | 12.41 | 2539 | 1229 | 3.38 / 400.96 | 2 | 2 |
8 | 13 | 801.52 | 39 | 13.20 | 1466 | 755 | 4.13 / 401.71 | 2 | 2 |
9 | 8 | 0.08 | 180 | 14.08 | 299 | 758 | 4.89 / 402.47 | 2 | 2 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 26 | 14.31 | 447 | 166 | 0.17 / 392.85 | 2 | 2 |
2 | 12 | 1116.64 | 5 | 12.17 | 1909 | 116 | 0.28 / 392.97 | 2 | 2 |
3 | 12 | 2001.40 | 30 | 11.14 | 3145 | 1051 | 1.33 / 394.02 | 2 | 2 |
4 | 7 | 1996.76 | 22 | 11.68 | 3109 | 799 | 2.13 / 394.82 | 2 | 2 |
5 | 13 | 1581.56 | 39 | 12.42 | 2549 | 1235 | 3.37 / 396.05 | 2 | 2 |
6 | 13 | 814.04 | 39 | 13.19 | 1490 | 766 | 4.13 / 396.82 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.08 | 301 | 763 | 4.90 / 397.58 | 2 | 3 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 26 | 14.30 | 447 | 166 | 0.17 / 388.13 | 2 | 2 |
2 | 12 | 1125.88 | 5 | 12.18 | 1932 | 118 | 0.28 / 388.24 | 2 | 2 |
3 | 12 | 2001.72 | 30 | 11.15 | 3141 | 1051 | 1.33 / 389.30 | 2 | 2 |
4 | 7 | 1997.04 | 22 | 11.68 | 3109 | 799 | 2.13 / 390.09 | 2 | 2 |
5 | 13 | 1597.04 | 39 | 12.42 | 2567 | 1243 | 3.38 / 391.34 | 2 | 2 |
6 | 13 | 554.00 | 39 | 13.49 | 1119 | 589 | 3.97 / 391.93 | 2 | 2 |
7 | 8 | 0.04 | 180 | 14.08 | 300 | 760 | 4.73 / 392.69 | 2 | 2 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 27 | 14.29 | 455 | 176 | 0.18 / 383.47 | 2 | 2 |
2 | 3 | 968.40 | -1 | 14.29 | 455 | 0 | 0.00 / 383.47 | 2 | 2 |
3 | 3 | 1025.48 | 1 | 11.99 | 1802 | 22 | 0.20 / 383.49 | 2 | 2 |
4 | 12 | 1138.60 | 5 | 12.18 | 1948 | 119 | 0.32 / 383.61 | 2 | 2 |
5 | 12 | 2002.16 | 30 | 11.16 | 3129 | 1048 | 1.36 / 384.66 | 2 | 2 |
6 | 7 | 1997.32 | 22 | 11.70 | 3118 | 803 | 2.17 / 385.46 | 2 | 2 |
7 | 13 | 1488.16 | 39 | 12.51 | 2426 | 1184 | 3.35 / 386.65 | 2 | 2 |
8 | 13 | 501.32 | 39 | 13.55 | 1043 | 551 | 3.90 / 387.20 | 2 | 2 |
9 | 8 | -0.12 | 180 | 14.07 | 301 | 762 | 4.66 / 387.96 | 2 | 2 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 25 | 14.29 | 472 | 169 | 0.17 / 378.79 | 2 | 2 |
2 | 3 | 1032.76 | 1 | 12.77 | 1831 | 23 | 0.19 / 378.82 | 2 | 2 |
3 | 3 | 1020.68 | 1 | 12.67 | 1824 | 23 | 0.22 / 378.84 | 2 | 2 |
4 | 12 | 1129.04 | 5 | 12.22 | 1943 | 119 | 0.33 / 378.96 | 2 | 2 |
5 | 12 | 2003.32 | 30 | 11.21 | 3118 | 1049 | 1.38 / 380.01 | 2 | 2 |
6 | 7 | 1998.72 | 22 | 11.67 | 3125 | 802 | 2.18 / 380.81 | 2 | 2 |
7 | 13 | 1485.60 | 39 | 12.48 | 2430 | 1183 | 3.37 / 381.99 | 2 | 2 |
8 | 13 | 474.48 | 39 | 13.58 | 1006 | 533 | 3.90 / 382.53 | 2 | 2 |
9 | 8 | 0.00 | 180 | 14.07 | 305 | 772 | 4.67 / 383.30 | 2 | 4 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 25 | 14.30 | 468 | 167 | 0.17 / 374.06 | 2 | 2 |
2 | 12 | 1107.88 | 4 | 11.80 | 1909 | 90 | 0.26 / 374.15 | 2 | 2 |
3 | 7 | 2002.44 | 44 | 11.13 | 3100 | 1518 | 1.78 / 375.67 | 2 | 2 |
4 | 13 | 1768.96 | 39 | 12.24 | 2800 | 1337 | 3.11 / 377.00 | 2 | 2 |
5 | 13 | 905.76 | 39 | 13.10 | 1620 | 828 | 3.94 / 377.83 | 2 | 2 |
6 | 8 | -0.20 | 180 | 14.07 | 313 | 793 | 4.73 / 378.62 | 2 | 2 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 25 | 14.33 | 443 | 159 | 0.16 / 369.34 | 2 | 2 |
2 | 12 | 1096.48 | 4 | 11.79 | 1904 | 90 | 0.25 / 369.43 | 2 | 2 |
3 | 7 | 2002.88 | 44 | 11.11 | 3111 | 1521 | 1.77 / 370.95 | 2 | 2 |
4 | 13 | 1769.44 | 39 | 12.24 | 2817 | 1345 | 3.11 / 372.30 | 2 | 2 |
5 | 13 | 894.68 | 39 | 13.13 | 1603 | 821 | 3.93 / 373.12 | 2 | 2 |
6 | 8 | 0.20 | 180 | 14.08 | 306 | 776 | 4.71 / 373.89 | 2 | 3 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 26 | 14.29 | 475 | 176 | 0.18 / 364.60 | 2 | 2 |
2 | 3 | 968.52 | -1 | 14.29 | 475 | 0 | 0.00 / 364.60 | 2 | 2 |
3 | 12 | 1141.48 | 3 | 11.02 | 1934 | 64 | 0.24 / 364.67 | 2 | 2 |
4 | 7 | 2004.48 | 44 | 11.18 | 3109 | 1529 | 1.77 / 366.20 | 2 | 2 |
5 | 13 | 1645.96 | 41 | 12.38 | 2630 | 1335 | 3.10 / 367.53 | 2 | 2 |
6 | 13 | 917.68 | 41 | 13.11 | 1639 | 881 | 3.99 / 368.41 | 2 | 2 |
7 | 8 | -0.04 | 180 | 14.10 | 303 | 769 | 4.75 / 369.18 | 2 | 2 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 26 | 14.31 | 478 | 178 | 0.18 / 359.90 | 2 | 2 |
2 | 12 | 1105.32 | 3 | 10.90 | 1886 | 62 | 0.24 / 359.96 | 2 | 2 |
3 | 7 | 2005.68 | 44 | 11.13 | 3113 | 1524 | 1.76 / 361.48 | 2 | 2 |
4 | 13 | 1764.40 | 41 | 12.26 | 2798 | 1406 | 3.17 / 362.89 | 2 | 2 |
5 | 13 | 751.20 | 41 | 13.29 | 1400 | 763 | 3.93 / 363.65 | 2 | 2 |
6 | 8 | 0.12 | 180 | 14.10 | 306 | 777 | 4.71 / 364.43 | 2 | 3 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 26 | 14.32 | 469 | 175 | 0.17 / 355.09 | 2 | 2 |
2 | 12 | 1106.40 | 3 | 10.65 | 1886 | 60 | 0.23 / 355.15 | 2 | 2 |
3 | 7 | 2002.72 | 45 | 11.03 | 3114 | 1546 | 1.78 / 356.69 | 2 | 2 |
4 | 13 | 1882.08 | 41 | 12.08 | 2962 | 1467 | 3.25 / 358.16 | 2 | 2 |
5 | 13 | 767.64 | 41 | 13.28 | 1421 | 774 | 4.02 / 358.93 | 2 | 2 |
6 | 8 | 0.04 | 180 | 14.09 | 309 | 784 | 4.80 / 359.72 | 2 | 3 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 26 | 14.31 | 479 | 178 | 0.18 / 350.22 | 2 | 2 |
2 | 12 | 1104.32 | 3 | 10.76 | 1878 | 61 | 0.24 / 350.28 | 2 | 2 |
3 | 7 | 2004.76 | 44 | 10.96 | 3142 | 1515 | 1.75 / 351.80 | 2 | 2 |
4 | 13 | 1756.96 | 41 | 12.29 | 2784 | 1403 | 3.16 / 353.20 | 2 | 2 |
5 | 13 | 1009.12 | 41 | 13.05 | 1763 | 943 | 4.10 / 354.14 | 2 | 2 |
6 | 8 | 0.12 | 180 | 14.13 | 302 | 768 | 4.87 / 354.91 | 2 | 2 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 26 | 14.33 | 463 | 173 | 0.17 / 345.51 | 2 | 2 |
2 | 12 | 1100.40 | 3 | 11.30 | 1878 | 64 | 0.24 / 345.58 | 2 | 2 |
3 | 7 | 2003.36 | 44 | 11.12 | 3108 | 1521 | 1.76 / 347.10 | 2 | 2 |
4 | 13 | 1753.80 | 41 | 12.32 | 2784 | 1406 | 3.16 / 348.50 | 2 | 2 |
5 | 13 | 762.72 | 41 | 13.32 | 1410 | 770 | 3.93 / 349.27 | 2 | 2 |
6 | 8 | -0.08 | 180 | 14.11 | 304 | 772 | 4.71 / 350.04 | 2 | 3 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 25 | 14.34 | 476 | 171 | 0.17 / 340.68 | 2 | 2 |
2 | 3 | 1029.72 | 1 | 12.83 | 1825 | 23 | 0.19 / 340.70 | 2 | 2 |
3 | 3 | 1021.04 | 1 | 12.70 | 1829 | 23 | 0.22 / 340.72 | 2 | 2 |
4 | 7 | 2009.48 | 44 | 10.97 | 3108 | 1500 | 1.72 / 342.22 | 2 | 2 |
5 | 13 | 1896.24 | 41 | 12.17 | 2982 | 1488 | 3.21 / 343.71 | 2 | 2 |
6 | 13 | 894.60 | 41 | 13.19 | 1600 | 865 | 4.07 / 344.58 | 2 | 2 |
7 | 8 | 0.16 | 180 | 14.12 | 300 | 762 | 4.83 / 345.34 | 2 | 2 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 26 | 14.35 | 462 | 172 | 0.17 / 335.75 | 2 | 2 |
2 | 3 | 969.60 | -1 | 14.35 | 462 | 0 | 0.00 / 335.75 | 2 | 2 |
3 | 3 | 1020.64 | 1 | 11.69 | 1819 | 21 | 0.19 / 335.77 | 2 | 2 |
4 | 7 | 2003.76 | 45 | 10.98 | 3112 | 1538 | 1.73 / 337.31 | 2 | 2 |
5 | 13 | 1890.72 | 41 | 12.18 | 2969 | 1483 | 3.21 / 338.79 | 2 | 2 |
6 | 13 | 991.56 | 41 | 13.11 | 1737 | 934 | 4.15 / 339.72 | 2 | 2 |
7 | 8 | -0.04 | 180 | 14.12 | 308 | 783 | 4.93 / 340.51 | 2 | 2 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 25 | 14.35 | 473 | 170 | 0.17 / 330.94 | 2 | 2 |
2 | 7 | 2002.68 | 44 | 11.11 | 3102 | 1516 | 1.69 / 332.45 | 2 | 2 |
3 | 13 | 1885.84 | 41 | 12.20 | 2962 | 1482 | 3.17 / 333.94 | 2 | 2 |
4 | 13 | 862.68 | 41 | 13.25 | 1554 | 844 | 4.01 / 334.78 | 2 | 2 |
5 | 8 | 0.24 | 180 | 14.11 | 313 | 795 | 4.81 / 335.58 | 2 | 4 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 26 | 14.36 | 464 | 173 | 0.17 / 326.12 | 2 | 2 |
2 | 3 | 967.84 | -1 | 14.36 | 464 | 0 | 0.00 / 326.12 | 2 | 2 |
3 | 3 | 1021.48 | 1 | 11.90 | 1807 | 22 | 0.19 / 326.14 | 2 | 2 |
4 | 7 | 2004.40 | 44 | 11.05 | 3123 | 1518 | 1.71 / 327.66 | 2 | 2 |
5 | 13 | 1884.44 | 41 | 12.22 | 2959 | 1483 | 3.20 / 329.14 | 2 | 2 |
6 | 13 | 855.36 | 41 | 13.27 | 1545 | 841 | 4.04 / 329.99 | 2 | 2 |
7 | 8 | 0.00 | 180 | 14.13 | 308 | 783 | 4.82 / 330.77 | 2 | 3 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 26 | 14.36 | 470 | 175 | 0.18 / 321.39 | 2 | 2 |
2 | 7 | 2004.72 | 44 | 11.18 | 3106 | 1528 | 1.70 / 322.92 | 2 | 2 |
3 | 13 | 1887.04 | 41 | 12.23 | 2971 | 1490 | 3.19 / 324.41 | 2 | 2 |
4 | 13 | 744.52 | 41 | 13.39 | 1387 | 761 | 3.95 / 325.17 | 2 | 2 |
5 | 8 | 0.16 | 180 | 14.13 | 307 | 781 | 4.74 / 325.95 | 2 | 3 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 25 | 14.39 | 458 | 165 | 0.16 / 316.77 | 2 | 2 |
2 | 12 | 1120.80 | 3 | 12.21 | 1926 | 71 | 0.24 / 316.84 | 2 | 2 |
3 | 7 | 2000.92 | 44 | 11.32 | 3107 | 1548 | 1.78 / 318.39 | 2 | 2 |
4 | 13 | 1636.96 | 41 | 12.51 | 2600 | 1334 | 3.12 / 319.72 | 2 | 2 |
5 | 13 | 653.52 | 41 | 13.49 | 1257 | 695 | 3.81 / 320.42 | 2 | 2 |
6 | 8 | 0.04 | 180 | 14.11 | 314 | 797 | 4.61 / 321.21 | 2 | 3 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 26 | 14.39 | 461 | 172 | 0.17 / 311.90 | 2 | 2 |
2 | 3 | 956.48 | -1 | 14.39 | 461 | 0 | 0.00 / 311.90 | 2 | 2 |
3 | 7 | 2002.88 | 51 | 11.24 | 3100 | 1777 | 1.95 / 313.68 | 2 | 2 |
4 | 13 | 1872.56 | 38 | 12.32 | 2944 | 1378 | 3.33 / 315.06 | 2 | 2 |
5 | 13 | 816.48 | 38 | 13.35 | 1487 | 754 | 4.08 / 315.81 | 2 | 2 |
6 | 8 | 0.08 | 180 | 14.13 | 311 | 791 | 4.87 / 316.60 | 2 | 2 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 25 | 14.40 | 467 | 168 | 0.17 / 306.94 | 2 | 2 |
2 | 3 | 1020.84 | 1 | 12.35 | 1820 | 22 | 0.19 / 306.97 | 2 | 2 |
3 | 3 | 1018.64 | 1 | 12.70 | 1827 | 23 | 0.21 / 306.99 | 2 | 2 |
4 | 7 | 2001.84 | 51 | 11.37 | 3111 | 1804 | 2.02 / 308.79 | 2 | 2 |
5 | 13 | 1744.16 | 38 | 12.52 | 2762 | 1314 | 3.33 / 310.11 | 2 | 2 |
6 | 13 | 982.48 | 38 | 13.22 | 1725 | 867 | 4.20 / 310.97 | 2 | 2 |
7 | 8 | -0.04 | 180 | 14.16 | 297 | 757 | 4.96 / 311.73 | 2 | 3 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 25 | 14.41 | 464 | 167 | 0.17 / 302.10 | 2 | 2 |
2 | 7 | 2007.92 | 50 | 11.40 | 3113 | 1774 | 1.94 / 303.87 | 2 | 2 |
3 | 13 | 1753.16 | 38 | 12.53 | 2786 | 1327 | 3.27 / 305.20 | 2 | 2 |
4 | 13 | 846.32 | 38 | 13.36 | 1534 | 779 | 4.05 / 305.98 | 2 | 2 |
5 | 8 | 0.04 | 180 | 14.13 | 313 | 796 | 4.84 / 306.78 | 2 | 3 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 26 | 14.43 | 448 | 168 | 0.17 / 296.95 | 2 | 2 |
2 | 3 | 972.20 | -1 | 14.43 | 448 | 0 | 0.00 / 296.95 | 2 | 2 |
3 | 3 | 1022.76 | 1 | 12.83 | 1824 | 23 | 0.19 / 296.97 | 2 | 2 |
4 | 7 | 2002.12 | 50 | 11.49 | 3109 | 1786 | 1.98 / 298.76 | 2 | 2 |
5 | 13 | 1744.32 | 38 | 12.56 | 2768 | 1321 | 3.30 / 300.08 | 2 | 2 |
6 | 13 | 979.44 | 38 | 13.25 | 1722 | 867 | 4.17 / 300.94 | 2 | 2 |
7 | 13 | 52.16 | 38 | 14.25 | 383 | 207 | 4.37 / 301.15 | 2 | 2 |
8 | 8 | -0.04 | 180 | 14.10 | 308 | 782 | 5.15 / 301.93 | 2 | 5 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 25 | 14.41 | 473 | 170 | 0.17 / 292.10 | 2 | 2 |
2 | 7 | 2005.96 | 50 | 11.56 | 3114 | 1800 | 1.97 / 293.90 | 2 | 2 |
3 | 13 | 1758.28 | 38 | 12.57 | 2794 | 1335 | 3.30 / 295.23 | 2 | 2 |
4 | 13 | 848.92 | 38 | 13.38 | 1537 | 781 | 4.09 / 296.01 | 2 | 2 |
5 | 8 | 0.12 | 180 | 14.16 | 300 | 765 | 4.85 / 296.78 | 2 | 2 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 25 | 14.43 | 453 | 163 | 0.16 / 287.25 | 2 | 2 |
2 | 7 | 2005.20 | 51 | 11.59 | 3112 | 1839 | 2.00 / 289.09 | 2 | 2 |
3 | 13 | 1744.96 | 32 | 12.71 | 2790 | 1135 | 3.14 / 290.22 | 2 | 2 |
4 | 13 | 988.16 | 32 | 13.34 | 1741 | 743 | 3.88 / 290.96 | 2 | 2 |
5 | 13 | 42.24 | 32 | 14.28 | 371 | 170 | 4.05 / 291.13 | 2 | 2 |
6 | 8 | -0.08 | 180 | 14.10 | 313 | 794 | 4.84 / 291.93 | 2 | 3 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 25 | 14.42 | 455 | 164 | 0.16 / 282.25 | 2 | 2 |
2 | 7 | 2004.72 | 51 | 11.69 | 3111 | 1855 | 2.02 / 284.11 | 2 | 2 |
3 | 13 | 1873.64 | 32 | 12.57 | 2950 | 1187 | 3.21 / 285.29 | 2 | 2 |
4 | 13 | 1097.92 | 32 | 13.26 | 1911 | 811 | 4.02 / 286.10 | 2 | 2 |
5 | 13 | 35.68 | 32 | 14.29 | 375 | 171 | 4.19 / 286.28 | 2 | 2 |
6 | 8 | -0.24 | 180 | 14.10 | 318 | 807 | 4.99 / 287.08 | 2 | 4 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 25 | 14.45 | 459 | 166 | 0.17 / 277.47 | 2 | 2 |
2 | 7 | 2003.52 | 50 | 11.82 | 3118 | 1843 | 2.01 / 279.31 | 2 | 2 |
3 | 13 | 1741.96 | 32 | 12.78 | 2782 | 1138 | 3.15 / 280.45 | 2 | 2 |
4 | 13 | 855.88 | 32 | 13.49 | 1553 | 670 | 3.82 / 281.12 | 2 | 2 |
5 | 13 | 48.16 | 32 | 14.28 | 379 | 173 | 3.99 / 281.29 | 2 | 2 |
6 | 8 | 0.04 | 180 | 14.11 | 313 | 795 | 4.78 / 282.09 | 2 | 3 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 26 | 14.46 | 441 | 166 | 0.17 / 272.53 | 2 | 2 |
2 | 3 | 957.72 | -1 | 14.46 | 441 | 0 | 0.00 / 272.53 | 2 | 2 |
3 | 7 | 2007.68 | 51 | 11.91 | 3120 | 1895 | 2.06 / 274.43 | 2 | 2 |
4 | 13 | 1875.72 | 32 | 12.63 | 2951 | 1193 | 3.25 / 275.62 | 2 | 2 |
5 | 13 | 951.48 | 32 | 13.42 | 1684 | 723 | 3.98 / 276.34 | 2 | 2 |
6 | 13 | 37.44 | 32 | 14.31 | 361 | 165 | 4.14 / 276.51 | 2 | 2 |
7 | 8 | -0.12 | 180 | 14.11 | 312 | 792 | 4.93 / 277.30 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 25 | 14.44 | 465 | 168 | 0.17 / 267.85 | 2 | 2 |
2 | 3 | 1030.32 | 1 | 13.49 | 1838 | 25 | 0.19 / 267.88 | 2 | 2 |
3 | 7 | 2003.36 | 50 | 12.04 | 3123 | 1880 | 2.07 / 269.76 | 2 | 2 |
4 | 13 | 1600.72 | 32 | 12.92 | 2597 | 1074 | 3.15 / 270.83 | 2 | 2 |
5 | 13 | 746.08 | 32 | 13.61 | 1394 | 607 | 3.75 / 271.44 | 2 | 2 |
6 | 13 | 50.48 | 32 | 14.28 | 380 | 174 | 3.93 / 271.61 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.14 | 297 | 756 | 4.68 / 272.37 | 2 | 3 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 25 | 14.46 | 459 | 166 | 0.17 / 263.05 | 2 | 2 |
2 | 7 | 2005.52 | 50 | 12.14 | 3118 | 1893 | 2.06 / 264.94 | 2 | 2 |
3 | 13 | 1737.28 | 32 | 12.87 | 2757 | 1135 | 3.19 / 266.08 | 2 | 2 |
4 | 13 | 825.20 | 32 | 13.54 | 1512 | 655 | 3.85 / 266.73 | 2 | 2 |
5 | 13 | 39.28 | 32 | 14.32 | 361 | 165 | 4.01 / 266.90 | 2 | 2 |
6 | 8 | -0.16 | 180 | 14.13 | 309 | 786 | 4.80 / 267.69 | 2 | 3 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 26 | 14.49 | 453 | 171 | 0.17 / 258.16 | 2 | 2 |
2 | 3 | 967.08 | -1 | 14.49 | 453 | 0 | 0.00 / 258.16 | 2 | 2 |
3 | 7 | 2006.88 | 50 | 12.23 | 3133 | 1916 | 2.09 / 260.08 | 2 | 2 |
4 | 13 | 1880.88 | 32 | 12.73 | 2978 | 1213 | 3.30 / 261.29 | 2 | 2 |
5 | 13 | 832.44 | 32 | 13.56 | 1521 | 660 | 3.96 / 261.95 | 2 | 2 |
6 | 13 | 39.48 | 32 | 14.32 | 367 | 168 | 4.13 / 262.12 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.15 | 300 | 764 | 4.89 / 262.88 | 2 | 5 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 25 | 14.49 | 468 | 170 | 0.17 / 253.27 | 2 | 2 |
2 | 3 | 1026.64 | 1 | 13.60 | 1831 | 25 | 0.19 / 253.29 | 2 | 2 |
3 | 3 | 1019.08 | 1 | 12.98 | 1844 | 24 | 0.22 / 253.32 | 2 | 2 |
4 | 7 | 2003.08 | 50 | 12.30 | 3126 | 1922 | 2.14 / 255.24 | 2 | 2 |
5 | 13 | 1736.84 | 32 | 12.91 | 2784 | 1150 | 3.29 / 256.39 | 2 | 2 |
6 | 13 | 842.84 | 32 | 13.56 | 1539 | 668 | 3.96 / 257.06 | 2 | 2 |
7 | 13 | 19.60 | 32 | 14.35 | 334 | 153 | 4.11 / 257.21 | 2 | 2 |
8 | 8 | -0.16 | 180 | 14.17 | 307 | 783 | 4.90 / 257.99 | 2 | 3 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 26 | 14.46 | 464 | 174 | 0.17 / 248.51 | 2 | 2 |
2 | 3 | 967.96 | -1 | 14.46 | 464 | 0 | 0.00 / 248.51 | 2 | 2 |
3 | 3 | 1019.92 | 1 | 12.96 | 1836 | 24 | 0.20 / 248.54 | 2 | 2 |
4 | 7 | 2002.32 | 50 | 12.31 | 3125 | 1923 | 2.12 / 250.46 | 2 | 2 |
5 | 13 | 1593.40 | 32 | 13.01 | 2591 | 1079 | 3.20 / 251.54 | 2 | 2 |
6 | 13 | 747.12 | 32 | 13.63 | 1405 | 613 | 3.81 / 252.15 | 2 | 2 |
7 | 13 | 23.00 | 32 | 14.34 | 345 | 158 | 3.97 / 252.31 | 2 | 2 |
8 | 8 | -0.20 | 180 | 14.16 | 309 | 788 | 4.76 / 253.10 | 2 | 3 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 25 | 14.46 | 468 | 169 | 0.17 / 243.59 | 2 | 2 |
2 | 3 | 1020.24 | 1 | 13.15 | 1841 | 24 | 0.19 / 243.62 | 2 | 2 |
3 | 7 | 2005.08 | 50 | 12.32 | 3129 | 1927 | 2.12 / 245.55 | 2 | 2 |
4 | 13 | 1745.40 | 32 | 12.91 | 2784 | 1150 | 3.27 / 246.70 | 2 | 2 |
5 | 13 | 841.48 | 32 | 13.56 | 1537 | 667 | 3.94 / 247.36 | 2 | 2 |
6 | 13 | 35.00 | 32 | 14.33 | 360 | 165 | 4.10 / 247.53 | 2 | 2 |
7 | 8 | -0.04 | 180 | 14.15 | 318 | 810 | 4.91 / 248.34 | 2 | 3 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 26 | 14.46 | 459 | 173 | 0.17 / 239.01 | 2 | 2 |
2 | 3 | 952.72 | -1 | 14.46 | 459 | 0 | 0.00 / 239.01 | 2 | 2 |
3 | 7 | 2007.52 | 50 | 12.31 | 3127 | 1925 | 2.10 / 240.93 | 2 | 2 |
4 | 13 | 1612.40 | 32 | 13.00 | 2596 | 1080 | 3.18 / 242.01 | 2 | 2 |
5 | 13 | 714.32 | 32 | 13.65 | 1365 | 596 | 3.77 / 242.61 | 2 | 2 |
6 | 8 | 0.08 | 180 | 14.19 | 319 | 815 | 4.59 / 243.43 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 25 | 14.49 | 472 | 171 | 0.17 / 234.09 | 2 | 2 |
2 | 3 | 1036.72 | 1 | 13.81 | 1840 | 25 | 0.20 / 234.11 | 2 | 2 |
3 | 7 | 2009.52 | 50 | 12.29 | 3135 | 1926 | 2.12 / 236.04 | 2 | 2 |
4 | 13 | 1739.44 | 32 | 12.90 | 2763 | 1141 | 3.26 / 237.18 | 2 | 2 |
5 | 13 | 849.24 | 32 | 13.55 | 1546 | 670 | 3.93 / 237.85 | 2 | 2 |
6 | 13 | 41.20 | 32 | 14.32 | 373 | 171 | 4.10 / 238.02 | 2 | 2 |
7 | 8 | -0.32 | 180 | 14.15 | 321 | 818 | 4.92 / 238.84 | 2 | 3 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 24 | 14.48 | 461 | 160 | 0.16 / 229.56 | 2 | 2 |
2 | 7 | 2003.72 | 51 | 12.24 | 3119 | 1947 | 2.11 / 231.51 | 2 | 2 |
3 | 13 | 1473.12 | 32 | 13.06 | 2407 | 1006 | 3.11 / 232.51 | 2 | 2 |
4 | 13 | 734.60 | 32 | 13.64 | 1378 | 601 | 3.71 / 233.12 | 2 | 2 |
5 | 8 | 0.12 | 180 | 14.23 | 312 | 799 | 4.51 / 233.92 | 2 | 3 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 25 | 14.47 | 468 | 169 | 0.17 / 224.80 | 2 | 2 |
2 | 3 | 964.88 | -1 | 14.47 | 468 | 0 | 0.00 / 224.80 | 2 | 2 |
3 | 7 | 2001.64 | 50 | 12.21 | 3116 | 1902 | 2.07 / 226.70 | 2 | 2 |
4 | 13 | 1604.20 | 32 | 12.95 | 2595 | 1075 | 3.15 / 227.78 | 2 | 2 |
5 | 13 | 872.56 | 32 | 13.52 | 1575 | 681 | 3.83 / 228.46 | 2 | 2 |
6 | 13 | 7.12 | 32 | 14.40 | 312 | 144 | 3.97 / 228.61 | 2 | 2 |
7 | 8 | -0.28 | 180 | 14.18 | 312 | 796 | 4.77 / 229.40 | 2 | 4 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 24 | 14.49 | 476 | 166 | 0.17 / 220.12 | 2 | 2 |
2 | 3 | 1040.48 | 1 | 13.83 | 1856 | 26 | 0.19 / 220.15 | 2 | 2 |
3 | 7 | 2002.08 | 50 | 12.16 | 3120 | 1897 | 2.09 / 222.04 | 2 | 2 |
4 | 13 | 1723.24 | 32 | 12.87 | 2751 | 1133 | 3.22 / 223.18 | 2 | 2 |
5 | 13 | 818.44 | 32 | 13.56 | 1496 | 649 | 3.87 / 223.82 | 2 | 2 |
6 | 8 | 0.00 | 180 | 14.21 | 316 | 808 | 4.68 / 224.63 | 2 | 3 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 25 | 14.47 | 472 | 171 | 0.17 / 215.39 | 2 | 2 |
2 | 3 | 972.72 | -1 | 14.47 | 472 | 0 | 0.00 / 215.39 | 2 | 2 |
3 | 3 | 1022.12 | 1 | 13.26 | 1838 | 24 | 0.20 / 215.41 | 2 | 2 |
4 | 7 | 2006.88 | 51 | 12.10 | 3131 | 1932 | 2.13 / 217.34 | 2 | 2 |
5 | 13 | 1596.64 | 30 | 12.96 | 2574 | 1001 | 3.13 / 218.35 | 2 | 2 |
6 | 13 | 868.00 | 30 | 13.51 | 1572 | 637 | 3.77 / 218.98 | 2 | 2 |
7 | 13 | 22.24 | 30 | 14.38 | 346 | 149 | 3.91 / 219.13 | 2 | 2 |
8 | 8 | 0.00 | 180 | 14.19 | 322 | 822 | 4.74 / 219.95 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 24 | 14.49 | 485 | 169 | 0.17 / 210.43 | 2 | 2 |
2 | 3 | 1030.72 | 1 | 13.82 | 1860 | 26 | 0.19 / 210.45 | 2 | 2 |
3 | 7 | 2005.52 | 50 | 12.12 | 3126 | 1894 | 2.09 / 212.35 | 2 | 2 |
4 | 13 | 1875.16 | 30 | 12.67 | 2963 | 1126 | 3.21 / 213.47 | 2 | 2 |
5 | 13 | 1083.12 | 30 | 13.34 | 1883 | 754 | 3.97 / 214.23 | 2 | 2 |
6 | 13 | 66.96 | 30 | 14.34 | 408 | 176 | 4.14 / 214.40 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.22 | 318 | 814 | 4.96 / 215.22 | 2 | 3 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 25 | 14.50 | 465 | 169 | 0.17 / 205.67 | 2 | 2 |
2 | 3 | 946.28 | -1 | 14.50 | 465 | 0 | 0.00 / 205.67 | 2 | 2 |
3 | 7 | 2004.72 | 51 | 12.11 | 3126 | 1931 | 2.10 / 207.60 | 2 | 2 |
4 | 13 | 1731.44 | 30 | 12.87 | 2748 | 1061 | 3.16 / 208.66 | 2 | 2 |
5 | 13 | 836.68 | 30 | 13.54 | 1544 | 627 | 3.79 / 209.29 | 2 | 2 |
6 | 13 | 19.96 | 30 | 14.39 | 351 | 152 | 3.94 / 209.44 | 2 | 2 |
7 | 8 | 0.04 | 180 | 14.20 | 321 | 820 | 4.76 / 210.26 | 2 | 3 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 23 | 14.54 | 478 | 160 | 0.16 / 200.89 | 2 | 2 |
2 | 3 | 1038.96 | 1 | 14.00 | 1844 | 26 | 0.19 / 200.92 | 2 | 2 |
3 | 7 | 2003.80 | 50 | 12.19 | 3127 | 1906 | 2.09 / 202.83 | 2 | 2 |
4 | 13 | 1589.84 | 30 | 12.98 | 2590 | 1009 | 3.10 / 203.83 | 2 | 2 |
5 | 13 | 987.40 | 30 | 13.45 | 1742 | 703 | 3.80 / 204.54 | 2 | 2 |
6 | 13 | 19.08 | 30 | 14.42 | 335 | 145 | 3.95 / 204.68 | 2 | 2 |
7 | 8 | -0.12 | 180 | 14.19 | 320 | 817 | 4.77 / 205.50 | 2 | 4 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 23 | 14.53 | 471 | 157 | 0.16 / 196.42 | 2 | 2 |
2 | 7 | 2007.88 | 51 | 12.22 | 3133 | 1953 | 2.11 / 198.37 | 2 | 2 |
3 | 13 | 1476.48 | 30 | 13.09 | 2426 | 953 | 3.06 / 199.32 | 2 | 2 |
4 | 13 | 745.64 | 30 | 13.67 | 1413 | 579 | 3.64 / 199.90 | 2 | 2 |
5 | 8 | 0.08 | 180 | 14.25 | 325 | 834 | 4.48 / 200.73 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 23 | 14.54 | 482 | 161 | 0.16 / 191.85 | 2 | 2 |
2 | 7 | 2004.84 | 46 | 12.33 | 3131 | 1776 | 1.94 / 193.62 | 2 | 2 |
3 | 13 | 1737.24 | 32 | 12.95 | 2758 | 1143 | 3.08 / 194.76 | 2 | 2 |
4 | 13 | 848.68 | 32 | 13.60 | 1552 | 675 | 3.76 / 195.44 | 2 | 2 |
5 | 8 | -0.08 | 180 | 14.26 | 319 | 819 | 4.57 / 196.26 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 24 | 14.54 | 471 | 164 | 0.16 / 187.28 | 2 | 2 |
2 | 3 | 959.32 | -1 | 14.54 | 471 | 0 | 0.00 / 187.28 | 2 | 2 |
3 | 7 | 2003.44 | 47 | 12.40 | 3136 | 1828 | 1.99 / 189.10 | 2 | 2 |
4 | 13 | 1724.04 | 32 | 12.99 | 2752 | 1144 | 3.14 / 190.25 | 2 | 2 |
5 | 13 | 713.72 | 32 | 13.73 | 1371 | 602 | 3.74 / 190.85 | 2 | 2 |
6 | 8 | 0.36 | 180 | 14.25 | 325 | 834 | 4.57 / 191.68 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 24 | 14.59 | 483 | 169 | 0.17 / 182.52 | 2 | 2 |
2 | 7 | 2004.00 | 46 | 12.46 | 3142 | 1801 | 1.97 / 184.32 | 2 | 2 |
3 | 13 | 1742.96 | 32 | 13.03 | 2740 | 1142 | 3.11 / 185.46 | 2 | 2 |
4 | 13 | 861.92 | 32 | 13.63 | 1571 | 685 | 3.80 / 186.15 | 2 | 2 |
5 | 13 | 1.80 | 32 | 14.50 | 316 | 147 | 3.94 / 186.29 | 2 | 2 |
6 | 8 | -0.20 | 180 | 14.25 | 320 | 821 | 4.77 / 187.11 | 2 | 4 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 24 | 14.58 | 491 | 172 | 0.17 / 177.86 | 2 | 2 |
2 | 7 | 2005.52 | 46 | 12.50 | 3141 | 1806 | 1.98 / 179.67 | 2 | 2 |
3 | 13 | 1749.84 | 32 | 13.02 | 2785 | 1160 | 3.14 / 180.83 | 2 | 2 |
4 | 13 | 848.72 | 32 | 13.65 | 1558 | 681 | 3.82 / 181.51 | 2 | 2 |
5 | 8 | 0.24 | 180 | 14.29 | 326 | 839 | 4.66 / 182.35 | 2 | 3 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 24 | 14.60 | 482 | 169 | 0.17 / 173.22 | 2 | 2 |
2 | 3 | 968.68 | -1 | 14.60 | 482 | 0 | 0.00 / 173.22 | 2 | 2 |
3 | 3 | 1022.68 | 1 | 13.79 | 1842 | 25 | 0.19 / 173.25 | 2 | 2 |
4 | 7 | 2004.68 | 46 | 12.55 | 3134 | 1809 | 2.00 / 175.06 | 2 | 2 |
5 | 13 | 1620.44 | 32 | 13.12 | 2626 | 1102 | 3.11 / 176.16 | 2 | 2 |
6 | 13 | 885.40 | 32 | 13.65 | 1600 | 699 | 3.80 / 176.86 | 2 | 2 |
7 | 8 | -0.20 | 180 | 14.31 | 323 | 832 | 4.64 / 177.69 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 24 | 14.60 | 486 | 170 | 0.17 / 168.54 | 2 | 2 |
2 | 7 | 2004.12 | 46 | 12.59 | 3145 | 1821 | 1.99 / 170.36 | 2 | 2 |
3 | 13 | 1741.76 | 32 | 13.09 | 2777 | 1163 | 3.15 / 171.53 | 2 | 2 |
4 | 13 | 855.80 | 32 | 13.70 | 1576 | 691 | 3.85 / 172.22 | 2 | 2 |
5 | 8 | 0.00 | 180 | 14.31 | 324 | 835 | 4.68 / 173.05 | 2 | 2 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 24 | 14.63 | 471 | 165 | 0.17 / 163.73 | 2 | 2 |
2 | 7 | 2005.56 | 47 | 12.66 | 3136 | 1866 | 2.03 / 165.60 | 2 | 2 |
3 | 13 | 1604.12 | 31 | 13.20 | 2606 | 1066 | 3.10 / 166.66 | 2 | 2 |
4 | 13 | 871.12 | 31 | 13.71 | 1582 | 672 | 3.77 / 167.34 | 2 | 2 |
5 | 13 | 20.40 | 31 | 14.52 | 342 | 154 | 3.92 / 167.49 | 2 | 2 |
6 | 8 | 0.04 | 190 | 14.29 | 325 | 882 | 4.81 / 168.37 | 2 | 4 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 23 | 14.62 | 494 | 166 | 0.17 / 159.05 | 2 | 2 |
2 | 3 | 1030.28 | 1 | 14.22 | 1855 | 26 | 0.19 / 159.08 | 2 | 2 |
3 | 7 | 2003.60 | 46 | 12.69 | 3138 | 1832 | 2.02 / 160.91 | 2 | 2 |
4 | 13 | 1746.28 | 31 | 13.13 | 2788 | 1135 | 3.16 / 162.05 | 2 | 2 |
5 | 13 | 870.56 | 31 | 13.73 | 1585 | 675 | 3.83 / 162.72 | 2 | 2 |
6 | 8 | 0.24 | 190 | 14.36 | 310 | 846 | 4.68 / 163.57 | 2 | 2 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 25 | 14.63 | 464 | 170 | 0.17 / 154.29 | 2 | 2 |
2 | 3 | 959.84 | -1 | 14.63 | 464 | 0 | 0.00 / 154.29 | 2 | 2 |
3 | 7 | 2004.12 | 46 | 12.72 | 3145 | 1840 | 2.01 / 156.13 | 2 | 2 |
4 | 13 | 1600.04 | 31 | 13.24 | 2597 | 1066 | 3.08 / 157.19 | 2 | 2 |
5 | 13 | 845.16 | 31 | 13.76 | 1549 | 661 | 3.74 / 157.85 | 2 | 2 |
6 | 13 | 19.00 | 31 | 14.54 | 340 | 153 | 3.89 / 158.01 | 2 | 2 |
7 | 8 | -0.20 | 190 | 14.28 | 324 | 879 | 4.77 / 158.89 | 2 | 8 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 25 | 14.64 | 474 | 173 | 0.17 / 149.47 | 2 | 2 |
2 | 7 | 2003.68 | 46 | 12.76 | 3141 | 1844 | 2.02 / 151.31 | 2 | 2 |
3 | 13 | 1726.28 | 31 | 13.17 | 2766 | 1129 | 3.15 / 152.44 | 2 | 2 |
4 | 13 | 847.52 | 31 | 13.77 | 1552 | 663 | 3.81 / 153.10 | 2 | 2 |
5 | 13 | 5.28 | 31 | 14.56 | 333 | 150 | 3.96 / 153.25 | 2 | 2 |
6 | 8 | 0.00 | 190 | 14.30 | 319 | 867 | 4.83 / 154.12 | 2 | 4 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 24 | 14.67 | 469 | 165 | 0.17 / 144.70 | 2 | 2 |
2 | 3 | 1027.48 | 1 | 14.28 | 1837 | 26 | 0.19 / 144.73 | 2 | 2 |
3 | 7 | 2002.68 | 47 | 12.78 | 3118 | 1873 | 2.06 / 146.60 | 2 | 2 |
4 | 13 | 1869.48 | 31 | 13.04 | 2957 | 1195 | 3.26 / 147.80 | 2 | 2 |
5 | 13 | 788.64 | 31 | 13.83 | 1467 | 629 | 3.89 / 148.42 | 2 | 2 |
6 | 8 | 0.20 | 190 | 14.36 | 318 | 868 | 4.76 / 149.29 | 2 | 3 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 24 | 14.66 | 448 | 158 | 0.16 / 140.15 | 2 | 2 |
2 | 7 | 2006.44 | 46 | 12.83 | 3140 | 1853 | 2.01 / 142.00 | 2 | 2 |
3 | 13 | 1489.32 | 31 | 13.34 | 2446 | 1012 | 3.02 / 143.01 | 2 | 2 |
4 | 13 | 900.80 | 31 | 13.76 | 1621 | 691 | 3.71 / 143.71 | 2 | 2 |
5 | 8 | 0.04 | 190 | 14.37 | 304 | 830 | 4.54 / 144.54 | 2 | 3 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 24 | 14.68 | 450 | 159 | 0.16 / 135.53 | 2 | 2 |
2 | 7 | 2003.12 | 47 | 12.83 | 3135 | 1890 | 2.05 / 137.42 | 2 | 2 |
3 | 13 | 1613.44 | 31 | 13.29 | 2593 | 1068 | 3.12 / 138.49 | 2 | 2 |
4 | 13 | 860.52 | 31 | 13.80 | 1561 | 668 | 3.79 / 139.16 | 2 | 2 |
5 | 8 | 0.00 | 190 | 14.38 | 306 | 836 | 4.62 / 139.99 | 2 | 3 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 25 | 14.65 | 458 | 168 | 0.17 / 130.75 | 2 | 2 |
2 | 3 | 934.68 | -1 | 14.65 | 458 | 0 | 0.00 / 130.75 | 2 | 2 |
3 | 7 | 2002.56 | 47 | 12.83 | 3134 | 1890 | 2.06 / 132.64 | 2 | 2 |
4 | 13 | 1591.80 | 31 | 13.29 | 2588 | 1066 | 3.12 / 133.70 | 2 | 2 |
5 | 13 | 848.16 | 31 | 13.81 | 1551 | 664 | 3.79 / 134.37 | 2 | 2 |
6 | 13 | 45.92 | 31 | 14.55 | 382 | 172 | 3.96 / 134.54 | 2 | 2 |
7 | 8 | -0.12 | 190 | 14.36 | 305 | 832 | 4.79 / 135.37 | 2 | 5 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 24 | 14.69 | 453 | 160 | 0.16 / 126.57 | 2 | 2 |
2 | 3 | 1024.00 | 1 | 14.34 | 1822 | 26 | 0.19 / 126.59 | 2 | 2 |
3 | 7 | 2004.12 | 41 | 12.97 | 3133 | 1666 | 1.85 / 128.26 | 2 | 2 |
4 | 13 | 1616.04 | 22 | 13.43 | 2625 | 776 | 2.63 / 129.03 | 2 | 2 |
5 | 13 | 976.28 | 22 | 13.84 | 1737 | 529 | 3.16 / 129.56 | 2 | 2 |
6 | 13 | 176.16 | 22 | 14.47 | 578 | 184 | 3.34 / 129.75 | 2 | 2 |
7 | 8 | 0.24 | 190 | 14.40 | 304 | 832 | 4.17 / 130.58 | 2 | 3 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 24 | 14.67 | 460 | 162 | 0.16 / 122.18 | 2 | 2 |
2 | 7 | 2007.56 | 41 | 12.97 | 3138 | 1669 | 1.83 / 123.85 | 2 | 2 |
3 | 13 | 1751.72 | 22 | 13.37 | 2797 | 823 | 2.65 / 124.67 | 2 | 2 |
4 | 13 | 1060.88 | 22 | 13.78 | 1858 | 563 | 3.22 / 125.24 | 2 | 2 |
5 | 13 | 508.04 | 22 | 14.20 | 1070 | 334 | 3.55 / 125.57 | 2 | 2 |
6 | 8 | -0.16 | 190 | 14.40 | 305 | 834 | 4.39 / 126.41 | 2 | 4 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 25 | 14.70 | 434 | 159 | 0.16 / 117.72 | 2 | 2 |
2 | 3 | 959.44 | -1 | 14.70 | 434 | 0 | 0.00 / 117.72 | 2 | 2 |
3 | 3 | 1020.92 | 1 | 14.21 | 1831 | 26 | 0.19 / 117.74 | 2 | 2 |
4 | 7 | 2002.32 | 40 | 13.03 | 3123 | 1628 | 1.81 / 119.37 | 2 | 2 |
5 | 13 | 1624.00 | 22 | 13.44 | 2642 | 781 | 2.59 / 120.15 | 2 | 2 |
6 | 13 | 1100.36 | 22 | 13.78 | 1912 | 580 | 3.17 / 120.73 | 2 | 2 |
7 | 13 | 541.72 | 22 | 14.18 | 1115 | 348 | 3.52 / 121.08 | 2 | 2 |
8 | 13 | 16.80 | 22 | 14.65 | 333 | 107 | 3.63 / 121.19 | 2 | 2 |
9 | 8 | 0.04 | 190 | 14.37 | 306 | 835 | 4.46 / 122.02 | 2 | 5 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 24 | 14.70 | 453 | 160 | 0.16 / 113.50 | 2 | 2 |
2 | 3 | 1036.88 | 1 | 14.44 | 1836 | 27 | 0.19 / 113.53 | 2 | 2 |
3 | 7 | 2003.52 | 40 | 13.03 | 3126 | 1629 | 1.82 / 115.16 | 2 | 2 |
4 | 13 | 1758.60 | 22 | 13.37 | 2820 | 829 | 2.65 / 115.99 | 2 | 2 |
5 | 13 | 1084.60 | 22 | 13.79 | 1884 | 572 | 3.22 / 116.56 | 2 | 2 |
6 | 13 | 162.68 | 22 | 14.52 | 550 | 176 | 3.39 / 116.73 | 2 | 2 |
7 | 8 | 0.16 | 190 | 14.43 | 300 | 823 | 4.21 / 117.56 | 2 | 2 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 25 | 14.69 | 438 | 161 | 0.16 / 109.30 | 2 | 2 |
2 | 3 | 950.60 | -1 | 14.69 | 438 | 0 | 0.00 / 109.30 | 2 | 2 |
3 | 7 | 2003.24 | 40 | 13.06 | 3106 | 1623 | 1.78 / 110.93 | 2 | 2 |
4 | 13 | 1632.56 | 22 | 13.46 | 2632 | 779 | 2.56 / 111.71 | 2 | 2 |
5 | 13 | 1089.16 | 22 | 13.80 | 1892 | 574 | 3.14 / 112.28 | 2 | 2 |
6 | 13 | 286.80 | 22 | 14.41 | 738 | 234 | 3.37 / 112.51 | 2 | 2 |
7 | 8 | 0.00 | 190 | 14.43 | 302 | 828 | 4.20 / 113.34 | 2 | 3 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 25 | 14.70 | 449 | 165 | 0.17 / 105.09 | 2 | 2 |
2 | 7 | 2008.16 | 40 | 13.05 | 3124 | 1631 | 1.80 / 106.72 | 2 | 2 |
3 | 13 | 1891.92 | 22 | 13.27 | 2991 | 873 | 2.67 / 107.60 | 2 | 2 |
4 | 13 | 1068.36 | 22 | 13.83 | 1857 | 565 | 3.23 / 108.16 | 2 | 2 |
5 | 13 | 135.04 | 22 | 14.56 | 508 | 163 | 3.40 / 108.32 | 2 | 2 |
6 | 8 | 0.08 | 190 | 14.42 | 299 | 819 | 4.22 / 109.14 | 2 | 4 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 25 | 14.70 | 442 | 162 | 0.16 / 100.86 | 2 | 2 |
2 | 7 | 2001.72 | 40 | 13.07 | 3102 | 1622 | 1.78 / 102.49 | 2 | 2 |
3 | 13 | 1738.32 | 22 | 13.41 | 2773 | 818 | 2.60 / 103.30 | 2 | 2 |
4 | 13 | 1180.16 | 22 | 13.76 | 2018 | 611 | 3.21 / 103.92 | 2 | 2 |
5 | 13 | 228.92 | 22 | 14.48 | 650 | 207 | 3.42 / 104.12 | 2 | 2 |
6 | 8 | -0.20 | 190 | 14.45 | 293 | 804 | 4.22 / 104.93 | 2 | 4 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 25 | 14.71 | 442 | 163 | 0.16 / 96.65 | 2 | 2 |
2 | 7 | 2003.76 | 40 | 13.06 | 3140 | 1640 | 1.80 / 98.29 | 2 | 2 |
3 | 13 | 1643.16 | 22 | 13.46 | 2637 | 781 | 2.58 / 99.07 | 2 | 2 |
4 | 13 | 1112.28 | 22 | 13.79 | 1924 | 584 | 3.17 / 99.66 | 2 | 2 |
5 | 13 | 299.00 | 22 | 14.40 | 755 | 239 | 3.41 / 99.90 | 2 | 2 |
6 | 8 | -0.16 | 190 | 14.43 | 294 | 806 | 4.21 / 100.70 | 2 | 3 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 25 | 14.70 | 438 | 161 | 0.16 / 92.52 | 2 | 2 |
2 | 7 | 2004.04 | 40 | 13.06 | 3140 | 1640 | 1.80 / 94.16 | 2 | 2 |
3 | 13 | 1626.24 | 21 | 13.46 | 2636 | 745 | 2.55 / 94.90 | 2 | 2 |
4 | 13 | 1106.76 | 21 | 13.80 | 1909 | 553 | 3.10 / 95.46 | 2 | 2 |
5 | 13 | 294.44 | 21 | 14.41 | 747 | 226 | 3.33 / 95.68 | 2 | 2 |
6 | 8 | 0.00 | 190 | 14.43 | 294 | 806 | 4.13 / 96.49 | 2 | 3 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 25 | 14.69 | 444 | 163 | 0.16 / 88.11 | 2 | 2 |
2 | 7 | 2004.96 | 40 | 13.07 | 3108 | 1625 | 1.79 / 89.73 | 2 | 2 |
3 | 13 | 1760.52 | 21 | 13.39 | 2804 | 788 | 2.58 / 90.52 | 2 | 2 |
4 | 13 | 1098.68 | 21 | 13.81 | 1901 | 551 | 3.13 / 91.07 | 2 | 2 |
5 | 13 | 414.20 | 21 | 14.32 | 925 | 278 | 3.41 / 91.35 | 2 | 2 |
6 | 13 | 22.12 | 21 | 14.67 | 340 | 105 | 3.51 / 91.46 | 2 | 2 |
7 | 13 | 12.16 | 21 | 14.59 | 323 | 99 | 3.61 / 91.56 | 2 | 2 |
8 | 8 | -0.12 | 190 | 14.37 | 294 | 803 | 4.41 / 92.36 | 2 | 7 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 24 | 14.70 | 442 | 156 | 0.16 / 83.90 | 2 | 2 |
2 | 7 | 2003.00 | 40 | 13.08 | 3108 | 1626 | 1.78 / 85.53 | 2 | 2 |
3 | 13 | 1762.36 | 21 | 13.39 | 2810 | 790 | 2.57 / 86.32 | 2 | 2 |
4 | 13 | 1083.28 | 21 | 13.81 | 1878 | 545 | 3.12 / 86.86 | 2 | 2 |
5 | 13 | 411.28 | 21 | 14.32 | 915 | 275 | 3.39 / 87.14 | 2 | 2 |
6 | 8 | 0.08 | 190 | 14.44 | 295 | 809 | 4.20 / 87.95 | 2 | 2 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 24 | 14.71 | 439 | 155 | 0.15 / 79.63 | 2 | 2 |
2 | 7 | 2001.68 | 40 | 13.06 | 3117 | 1628 | 1.78 / 81.26 | 2 | 2 |
3 | 13 | 1750.40 | 21 | 13.40 | 2791 | 785 | 2.57 / 82.04 | 2 | 2 |
4 | 13 | 1199.12 | 21 | 13.75 | 2043 | 590 | 3.16 / 82.63 | 2 | 2 |
5 | 13 | 502.32 | 21 | 14.25 | 1041 | 312 | 3.47 / 82.94 | 2 | 2 |
6 | 8 | 0.36 | 190 | 14.43 | 292 | 801 | 4.27 / 83.74 | 2 | 3 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 24 | 14.71 | 446 | 157 | 0.16 / 75.50 | 2 | 2 |
2 | 7 | 2003.44 | 40 | 13.08 | 3124 | 1634 | 1.79 / 77.13 | 2 | 2 |
3 | 13 | 1626.28 | 21 | 13.48 | 2637 | 746 | 2.54 / 77.88 | 2 | 2 |
4 | 13 | 1119.24 | 21 | 13.80 | 1927 | 558 | 3.10 / 78.43 | 2 | 2 |
5 | 13 | 307.72 | 21 | 14.42 | 757 | 229 | 3.33 / 78.66 | 2 | 2 |
6 | 8 | -0.04 | 190 | 14.45 | 295 | 810 | 4.14 / 79.47 | 2 | 2 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 25 | 14.69 | 446 | 164 | 0.16 / 71.30 | 2 | 2 |
2 | 3 | 927.44 | -1 | 14.69 | 446 | 0 | 0.00 / 71.30 | 2 | 2 |
3 | 7 | 2002.76 | 47 | 13.01 | 3101 | 1896 | 2.06 / 73.20 | 2 | 2 |
4 | 13 | 1378.08 | 28 | 13.53 | 2293 | 869 | 2.93 / 74.07 | 2 | 2 |
5 | 13 | 597.12 | 28 | 14.11 | 1184 | 468 | 3.40 / 74.54 | 2 | 2 |
6 | 8 | -0.04 | 190 | 14.45 | 292 | 802 | 4.20 / 75.34 | 2 | 3 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 25 | 14.72 | 446 | 164 | 0.16 / 67.04 | 2 | 2 |
2 | 7 | 2003.72 | 46 | 13.01 | 3098 | 1854 | 2.02 / 68.89 | 2 | 2 |
3 | 13 | 1480.84 | 28 | 13.47 | 2441 | 921 | 2.94 / 69.81 | 2 | 2 |
4 | 13 | 637.80 | 28 | 14.08 | 1247 | 492 | 3.43 / 70.31 | 2 | 2 |
5 | 8 | 0.24 | 190 | 14.43 | 304 | 833 | 4.26 / 71.14 | 2 | 2 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 25 | 14.72 | 445 | 164 | 0.16 / 62.64 | 2 | 2 |
2 | 7 | 2002.80 | 47 | 13.00 | 3088 | 1887 | 2.05 / 64.53 | 2 | 2 |
3 | 13 | 1478.96 | 28 | 13.48 | 2426 | 916 | 2.97 / 65.44 | 2 | 2 |
4 | 13 | 652.16 | 28 | 14.06 | 1256 | 494 | 3.46 / 65.94 | 2 | 2 |
5 | 13 | 13.28 | 28 | 14.69 | 326 | 134 | 3.59 / 66.07 | 2 | 2 |
6 | 8 | -0.28 | 190 | 14.38 | 295 | 806 | 4.40 / 66.88 | 2 | 7 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 25 | 14.73 | 458 | 169 | 0.17 / 58.24 | 2 | 2 |
2 | 3 | 1022.60 | 1 | 14.53 | 1817 | 26 | 0.20 / 58.27 | 2 | 2 |
3 | 7 | 2002.40 | 46 | 13.02 | 3107 | 1861 | 2.06 / 60.13 | 2 | 2 |
4 | 13 | 1471.84 | 28 | 13.48 | 2421 | 914 | 2.97 / 61.05 | 2 | 2 |
5 | 13 | 648.08 | 28 | 14.06 | 1258 | 495 | 3.46 / 61.54 | 2 | 2 |
6 | 13 | 1.44 | 28 | 14.72 | 306 | 126 | 3.59 / 61.67 | 2 | 2 |
7 | 8 | -0.16 | 190 | 14.36 | 296 | 808 | 4.40 / 62.47 | 2 | 6 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 25 | 14.72 | 457 | 168 | 0.17 / 54.02 | 2 | 2 |
2 | 7 | 2006.44 | 46 | 13.00 | 3102 | 1855 | 2.02 / 55.87 | 2 | 2 |
3 | 13 | 1510.04 | 28 | 13.45 | 2469 | 930 | 2.95 / 56.80 | 2 | 2 |
4 | 13 | 561.84 | 28 | 14.13 | 1137 | 450 | 3.40 / 57.25 | 2 | 2 |
5 | 8 | 0.08 | 190 | 14.44 | 301 | 826 | 4.23 / 58.08 | 2 | 4 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 25 | 14.72 | 454 | 167 | 0.17 / 49.65 | 2 | 2 |
2 | 7 | 2004.64 | 47 | 13.00 | 3095 | 1891 | 2.06 / 51.54 | 2 | 2 |
3 | 13 | 1482.88 | 28 | 13.47 | 2434 | 918 | 2.98 / 52.46 | 2 | 2 |
4 | 13 | 781.80 | 28 | 13.95 | 1449 | 566 | 3.54 / 53.02 | 2 | 2 |
5 | 8 | 0.00 | 190 | 14.45 | 300 | 824 | 4.37 / 53.85 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 25 | 14.72 | 460 | 169 | 0.17 / 45.29 | 2 | 2 |
2 | 7 | 2004.64 | 46 | 13.01 | 3109 | 1861 | 2.03 / 47.15 | 2 | 2 |
3 | 13 | 1611.08 | 28 | 13.40 | 2563 | 962 | 2.99 / 48.11 | 2 | 2 |
4 | 13 | 759.52 | 28 | 13.96 | 1416 | 553 | 3.55 / 48.67 | 2 | 2 |
5 | 8 | 0.16 | 190 | 14.46 | 297 | 816 | 4.36 / 49.48 | 2 | 2 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 25 | 14.70 | 460 | 169 | 0.17 / 41.00 | 2 | 2 |
2 | 7 | 2005.12 | 46 | 13.00 | 3096 | 1851 | 2.02 / 42.86 | 2 | 2 |
3 | 13 | 1496.60 | 28 | 13.45 | 2450 | 923 | 2.94 / 43.78 | 2 | 2 |
4 | 13 | 674.52 | 28 | 14.02 | 1301 | 511 | 3.45 / 44.29 | 2 | 2 |
5 | 8 | 0.08 | 190 | 14.44 | 303 | 831 | 4.29 / 45.12 | 2 | 3 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 25 | 14.72 | 444 | 163 | 0.16 / 36.67 | 2 | 2 |
2 | 3 | 972.72 | -1 | 14.72 | 444 | 0 | 0.00 / 36.67 | 2 | 2 |
3 | 3 | 1030.16 | 1 | 14.52 | 1834 | 27 | 0.19 / 36.70 | 2 | 2 |
4 | 7 | 2002.96 | 47 | 12.99 | 3101 | 1893 | 2.08 / 38.59 | 2 | 2 |
5 | 13 | 1483.68 | 28 | 13.44 | 2432 | 915 | 3.00 / 39.51 | 2 | 2 |
6 | 13 | 652.12 | 28 | 14.03 | 1267 | 498 | 3.50 / 40.00 | 2 | 2 |
7 | 8 | -0.04 | 190 | 14.44 | 303 | 831 | 4.33 / 40.84 | 2 | 2 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 25 | 14.72 | 450 | 166 | 0.17 / 32.42 | 2 | 2 |
2 | 7 | 2001.72 | 46 | 13.00 | 3075 | 1839 | 2.00 / 34.26 | 2 | 2 |
3 | 13 | 1363.52 | 28 | 13.50 | 2258 | 854 | 2.86 / 35.12 | 2 | 2 |
4 | 13 | 561.16 | 28 | 14.10 | 1131 | 447 | 3.30 / 35.56 | 2 | 2 |
5 | 13 | 2.64 | 28 | 14.75 | 307 | 127 | 3.43 / 35.69 | 2 | 2 |
6 | 8 | 0.12 | 190 | 14.39 | 299 | 817 | 4.25 / 36.51 | 2 | 4 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 26 | 14.68 | 438 | 167 | 0.17 / 28.20 | 2 | 2 |
2 | 3 | 962.60 | -1 | 14.68 | 438 | 0 | 0.00 / 28.20 | 2 | 2 |
3 | 3 | 1019.60 | 1 | 14.47 | 1823 | 26 | 0.19 / 28.23 | 2 | 2 |
4 | 7 | 2001.16 | 46 | 12.98 | 3099 | 1850 | 2.04 / 30.08 | 2 | 2 |
5 | 13 | 1363.64 | 28 | 13.48 | 2262 | 854 | 2.90 / 30.93 | 2 | 2 |
6 | 13 | 683.88 | 28 | 13.99 | 1305 | 511 | 3.41 / 31.44 | 2 | 2 |
7 | 8 | -0.04 | 190 | 14.45 | 298 | 818 | 4.23 / 32.26 | 2 | 2 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 26 | 14.70 | 454 | 174 | 0.17 / 24.06 | 2 | 2 |
2 | 7 | 2004.40 | 46 | 12.94 | 3083 | 1835 | 2.01 / 25.90 | 2 | 2 |
3 | 13 | 1476.00 | 28 | 13.41 | 2374 | 891 | 2.90 / 26.79 | 2 | 2 |
4 | 13 | 527.28 | 28 | 14.12 | 1085 | 429 | 3.33 / 27.22 | 2 | 2 |
5 | 8 | 0.12 | 190 | 14.44 | 296 | 812 | 4.14 / 28.03 | 2 | 3 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 25 | 14.67 | 461 | 169 | 0.17 / 19.84 | 2 | 2 |
2 | 7 | 2001.72 | 49 | 12.89 | 3076 | 1943 | 2.11 / 21.79 | 2 | 2 |
3 | 13 | 1452.96 | 25 | 13.45 | 2379 | 800 | 2.91 / 22.59 | 2 | 2 |
4 | 13 | 739.28 | 25 | 13.96 | 1385 | 483 | 3.40 / 23.07 | 2 | 2 |
5 | 8 | 0.00 | 190 | 14.42 | 300 | 822 | 4.22 / 23.89 | 2 | 4 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 25 | 14.71 | 457 | 168 | 0.17 / 15.60 | 2 | 2 |
2 | 7 | 1992.96 | 50 | 12.87 | 3056 | 1967 | 2.13 / 17.56 | 2 | 2 |
3 | 13 | 1317.32 | 25 | 13.51 | 2172 | 734 | 2.87 / 18.30 | 2 | 2 |
4 | 13 | 639.44 | 25 | 14.02 | 1244 | 436 | 3.30 / 18.73 | 2 | 2 |
5 | 13 | 14.20 | 25 | 14.71 | 334 | 123 | 3.43 / 18.86 | 2 | 2 |
6 | 8 | -0.20 | 190 | 14.35 | 300 | 818 | 4.24 / 19.67 | 2 | 5 |
Average= | 3.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 25 | 14.68 | 450 | 165 | 0.17 / 12.07 | 2 | 2 |
2 | 7 | 1509.40 | 50 | 13.21 | 2453 | 1620 | 1.79 / 13.69 | 2 | 2 |
3 | 13 | 1133.76 | 25 | 13.62 | 1949 | 664 | 2.45 / 14.35 | 2 | 2 |
4 | 13 | 306.28 | 25 | 14.36 | 765 | 275 | 2.72 / 14.63 | 2 | 2 |
5 | 8 | 0.00 | 190 | 14.43 | 293 | 803 | 3.53 / 15.43 | 2 | 3 |
Average= | 3.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 23 | 14.65 | 450 | 152 | 0.15 / 8.47 | 2 | 2 |
2 | 3 | 1065.80 | 2 | 14.40 | 1888 | 54 | 0.21 / 8.53 | 2 | 2 |
3 | 3 | 1024.52 | 1 | 14.38 | 1811 | 26 | 0.23 / 8.55 | 2 | 2 |
4 | 7 | 1512.76 | 49 | 13.15 | 2458 | 1584 | 1.82 / 10.14 | 2 | 2 |
5 | 13 | 1150.00 | 25 | 13.56 | 1965 | 666 | 2.48 / 10.80 | 2 | 2 |
6 | 13 | 335.72 | 25 | 14.28 | 808 | 288 | 2.77 / 11.09 | 2 | 2 |
7 | 8 | 0.08 | 190 | 14.40 | 296 | 810 | 3.58 / 11.90 | 2 | 2 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 27 | 14.55 | 445 | 175 | 0.17 / 4.51 | 2 | 2 |
2 | 3 | 902.08 | -2 | 14.55 | 445 | 0 | 0.00 / 4.51 | 2 | 2 |
3 | 3 | 924.08 | -1 | 14.55 | 445 | 0 | 0.00 / 4.51 | 2 | 2 |
4 | 7 | 1512.24 | 74 | 12.88 | 2448 | 2333 | 2.51 / 6.85 | 2 | 2 |
5 | 13 | 475.16 | 25 | 14.07 | 1007 | 354 | 2.86 / 7.20 | 2 | 2 |
6 | 13 | 11.44 | 25 | 14.65 | 320 | 117 | 2.98 / 7.32 | 2 | 2 |
7 | 8 | -0.08 | 240 | 14.26 | 293 | 1003 | 3.98 / 8.32 | 2 | 96 |
Average= | 2.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 26 | 14.50 | 435 | 164 | 0.16 / 1.71 | 2 | 2 |
2 | 3 | 965.20 | -1 | 14.50 | 435 | 0 | 0.00 / 1.71 | 2 | 2 |
3 | 7 | 989.36 | 74 | 13.10 | 1693 | 1641 | 1.81 / 3.35 | 2 | 2 |
4 | 8 | 0.08 | 240 | 14.27 | 289 | 990 | 2.79 / 4.34 | 2 | 32 |
Average= | 2.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 125.96 | 26 | 14.12 | 452 | 166 | 0.17 / 0.17 | 2 | 2 |
2 | 7 | 134.84 | 74 | 13.97 | 456 | 471 | 0.64 / 0.64 | 2 | 2 |
3 | 8 | 0.28 | 240 | 14.32 | 264 | 907 | 1.54 / 1.54 | 2 | 63 |
Average= | 1.54 (KJ/cycle) |