SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 33 | 10.17 | 520 | 175 | 0.17 / 1713.09 | 2 | 5 |
2 | 12 | 1104.28 | 114 | 7.64 | 1880 | 1637 | 1.81 / 1714.72 | 2 | 2 |
3 | 7 | 1098.36 | 21 | 7.64 | 1868 | 300 | 2.11 / 1715.02 | 2 | 2 |
4 | 13 | 646.56 | 36 | 8.72 | 1254 | 394 | 2.51 / 1715.42 | 2 | 2 |
5 | 13 | 106.00 | 5 | 10.18 | 511 | 26 | 2.53 / 1715.44 | 2 | 4 |
6 | 13 | 75.48 | 5 | 10.27 | 472 | 24 | 2.56 / 1715.47 | 2 | 5 |
7 | 13 | 65.52 | 5 | 10.31 | 461 | 24 | 2.58 / 1715.49 | 2 | 5 |
8 | 13 | 1.72 | 36 | 10.50 | 349 | 132 | 2.71 / 1715.62 | 2 | 4 |
9 | 8 | 0.08 | 190 | 10.51 | 335 | 669 | 3.38 / 1716.29 | 2 | 14 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 26 | 10.24 | 507 | 135 | 0.13 / 1709.60 | 2 | 4 |
2 | 10 | 1019.24 | 5 | 8.17 | 1779 | 73 | 0.21 / 1709.68 | 2 | 2 |
3 | 10 | 1052.08 | 3 | 8.05 | 1819 | 44 | 0.25 / 1709.72 | 2 | 2 |
4 | 3 | 1028.72 | 1 | 8.28 | 1808 | 15 | 0.27 / 1709.74 | 2 | 2 |
5 | 12 | 1128.04 | 114 | 7.74 | 1911 | 1686 | 1.95 / 1711.42 | 2 | 2 |
6 | 7 | 1123.36 | 21 | 7.70 | 1901 | 307 | 2.26 / 1711.73 | 2 | 2 |
7 | 13 | 656.36 | 36 | 8.82 | 1264 | 401 | 2.66 / 1712.13 | 2 | 2 |
8 | 13 | 69.64 | 5 | 10.38 | 456 | 24 | 2.69 / 1712.15 | 2 | 5 |
9 | 13 | 57.52 | 5 | 10.40 | 443 | 23 | 2.71 / 1712.18 | 2 | 5 |
10 | 13 | 49.32 | 5 | 10.40 | 428 | 22 | 2.73 / 1712.20 | 2 | 5 |
11 | 13 | 45.08 | 5 | 10.42 | 419 | 22 | 2.75 / 1712.22 | 2 | 5 |
12 | 13 | 42.36 | 5 | 10.43 | 415 | 22 | 2.77 / 1712.24 | 2 | 5 |
13 | 8 | 0.08 | 190 | 10.56 | 333 | 668 | 3.44 / 1712.91 | 2 | 17 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 187.68 | 33 | 10.08 | 623 | 207 | 0.21 / 1706.26 | 2 | 4 |
2 | 3 | 766.64 | -4 | 10.08 | 623 | 0 | 0.00 / 1706.26 | 2 | 4 |
3 | 3 | 957.00 | -1 | 10.08 | 623 | 0 | 0.00 / 1706.26 | 2 | 4 |
4 | 12 | 1146.52 | 114 | 7.81 | 1937 | 1725 | 1.93 / 1707.98 | 2 | 2 |
5 | 7 | 1141.60 | 20 | 7.82 | 1930 | 302 | 2.23 / 1708.28 | 2 | 2 |
6 | 13 | 679.44 | 36 | 8.85 | 1299 | 414 | 2.65 / 1708.70 | 2 | 2 |
7 | 13 | 115.76 | 5 | 10.29 | 528 | 27 | 2.67 / 1708.72 | 2 | 4 |
8 | 13 | 56.00 | 5 | 10.43 | 444 | 23 | 2.70 / 1708.75 | 2 | 5 |
9 | 13 | 47.32 | 5 | 10.45 | 427 | 22 | 2.72 / 1708.77 | 2 | 5 |
10 | 13 | 43.48 | 5 | 10.46 | 421 | 22 | 2.74 / 1708.79 | 2 | 5 |
11 | 8 | -0.04 | 190 | 10.59 | 337 | 678 | 3.42 / 1709.47 | 2 | 13 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 127.68 | 32 | 10.31 | 521 | 172 | 0.17 / 1701.45 | 2 | 4 |
2 | 3 | 690.44 | -6 | 10.31 | 521 | 0 | 0.00 / 1701.45 | 2 | 4 |
3 | 3 | 928.72 | -1 | 10.31 | 521 | 0 | 0.00 / 1701.45 | 2 | 4 |
4 | 12 | 1156.44 | 5 | 8.17 | 1972 | 81 | 0.25 / 1701.53 | 2 | 2 |
5 | 12 | 2002.92 | 114 | 6.37 | 3108 | 2257 | 2.51 / 1703.78 | 2 | 2 |
6 | 7 | 1988.28 | 20 | 6.36 | 3103 | 395 | 2.90 / 1704.18 | 2 | 2 |
7 | 13 | 1770.20 | 36 | 6.75 | 2791 | 678 | 3.58 / 1704.86 | 2 | 2 |
8 | 13 | 1338.96 | 36 | 7.53 | 2210 | 599 | 4.18 / 1705.46 | 2 | 2 |
9 | 13 | 890.36 | 36 | 8.43 | 1599 | 485 | 4.67 / 1705.94 | 2 | 2 |
10 | 13 | 194.88 | 5 | 10.12 | 637 | 32 | 4.70 / 1705.97 | 2 | 4 |
11 | 13 | 112.92 | 5 | 10.33 | 525 | 27 | 4.73 / 1706.00 | 2 | 5 |
12 | 13 | 73.44 | 5 | 10.41 | 470 | 24 | 4.75 / 1706.03 | 2 | 5 |
13 | 13 | 55.48 | 5 | 10.45 | 446 | 23 | 4.77 / 1706.05 | 2 | 5 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 31 | 10.41 | 506 | 163 | 0.16 / 1698.80 | 2 | 4 |
2 | 3 | 1030.80 | 1 | 8.60 | 1802 | 15 | 0.18 / 1698.82 | 2 | 2 |
3 | 12 | 1129.04 | 114 | 8.15 | 1915 | 1779 | 1.96 / 1700.60 | 2 | 2 |
4 | 7 | 1121.80 | 21 | 8.16 | 1907 | 327 | 2.28 / 1700.92 | 2 | 2 |
5 | 13 | 425.48 | 36 | 9.64 | 942 | 327 | 2.61 / 1701.25 | 2 | 3 |
6 | 13 | 63.80 | 5 | 10.54 | 444 | 23 | 2.64 / 1701.27 | 2 | 5 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 33 | 10.43 | 494 | 170 | 0.17 / 1695.42 | 2 | 4 |
2 | 12 | 1106.80 | 114 | 8.26 | 1891 | 1781 | 1.95 / 1697.20 | 2 | 2 |
3 | 7 | 1098.56 | 21 | 8.31 | 1882 | 328 | 2.28 / 1697.53 | 2 | 2 |
4 | 13 | 618.68 | 36 | 9.30 | 1216 | 407 | 2.69 / 1697.93 | 2 | 3 |
5 | 13 | 87.40 | 5 | 10.51 | 473 | 25 | 2.71 / 1697.96 | 2 | 5 |
6 | 8 | 0.16 | 190 | 10.70 | 335 | 681 | 3.39 / 1698.64 | 2 | 15 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 30 | 10.53 | 489 | 154 | 0.15 / 1692.17 | 2 | 4 |
2 | 10 | 1007.32 | 3 | 8.77 | 1786 | 47 | 0.20 / 1692.21 | 2 | 2 |
3 | 12 | 1115.32 | 114 | 8.35 | 1906 | 1814 | 2.02 / 1694.03 | 2 | 2 |
4 | 7 | 1108.48 | 21 | 8.38 | 1892 | 333 | 2.35 / 1694.36 | 2 | 2 |
5 | 13 | 384.16 | 8 | 9.87 | 907 | 72 | 2.42 / 1694.43 | 2 | 3 |
6 | 13 | 200.44 | 5 | 10.27 | 647 | 33 | 2.45 / 1694.47 | 2 | 4 |
7 | 13 | 121.56 | 5 | 10.44 | 537 | 28 | 2.48 / 1694.49 | 2 | 4 |
8 | 13 | 82.40 | 5 | 10.52 | 482 | 25 | 2.51 / 1694.52 | 2 | 5 |
9 | 13 | 60.96 | 5 | 10.60 | 449 | 24 | 2.53 / 1694.54 | 2 | 5 |
10 | 13 | 50.08 | 5 | 10.61 | 433 | 23 | 2.55 / 1694.57 | 2 | 5 |
11 | 8 | -0.04 | 190 | 10.72 | 334 | 680 | 3.23 / 1695.25 | 2 | 16 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 32 | 10.51 | 498 | 167 | 0.17 / 1686.98 | 2 | 4 |
2 | 12 | 1108.32 | 5 | 8.53 | 1908 | 81 | 0.25 / 1687.06 | 2 | 2 |
3 | 12 | 2001.72 | 114 | 7.05 | 3128 | 2514 | 2.76 / 1689.58 | 2 | 2 |
4 | 7 | 1986.16 | 21 | 7.13 | 3115 | 466 | 3.23 / 1690.04 | 2 | 2 |
5 | 13 | 1306.56 | 36 | 8.18 | 2185 | 643 | 3.87 / 1690.69 | 2 | 2 |
6 | 13 | 628.88 | 36 | 9.41 | 1244 | 421 | 4.29 / 1691.11 | 2 | 3 |
7 | 13 | 109.92 | 5 | 10.52 | 518 | 27 | 4.32 / 1691.14 | 2 | 5 |
8 | 13 | 75.96 | 5 | 10.59 | 475 | 25 | 4.35 / 1691.16 | 2 | 5 |
9 | 13 | 47.92 | 5 | 10.63 | 434 | 23 | 4.37 / 1691.19 | 2 | 5 |
10 | 13 | 2.88 | 36 | 10.71 | 354 | 136 | 4.51 / 1691.32 | 2 | 10 |
11 | 8 | 0.00 | 190 | 10.74 | 339 | 692 | 5.20 / 1692.01 | 2 | 13 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 31 | 10.51 | 500 | 163 | 0.16 / 1683.65 | 2 | 4 |
2 | 12 | 1121.48 | 114 | 8.52 | 1917 | 1862 | 2.02 / 1685.51 | 2 | 2 |
3 | 7 | 1115.00 | 21 | 8.57 | 1906 | 343 | 2.37 / 1685.85 | 2 | 2 |
4 | 13 | 382.12 | 8 | 9.96 | 908 | 72 | 2.44 / 1685.92 | 2 | 3 |
5 | 13 | 203.56 | 5 | 10.37 | 647 | 34 | 2.47 / 1685.96 | 2 | 4 |
6 | 13 | 115.84 | 5 | 10.53 | 528 | 28 | 2.50 / 1685.99 | 2 | 4 |
7 | 13 | 16.64 | 36 | 10.70 | 365 | 141 | 2.64 / 1686.13 | 2 | 5 |
8 | 8 | 0.16 | 190 | 10.76 | 337 | 689 | 3.33 / 1686.82 | 2 | 17 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 33 | 10.54 | 493 | 171 | 0.17 / 1680.20 | 2 | 4 |
2 | 3 | 889.60 | -2 | 10.54 | 493 | 0 | 0.00 / 1680.20 | 2 | 4 |
3 | 12 | 1114.96 | 114 | 8.59 | 1910 | 1870 | 2.04 / 1682.07 | 2 | 2 |
4 | 7 | 1106.76 | 20 | 8.66 | 1900 | 329 | 2.37 / 1682.40 | 2 | 2 |
5 | 13 | 214.48 | 5 | 10.34 | 666 | 34 | 2.41 / 1682.43 | 2 | 4 |
6 | 13 | 124.92 | 5 | 10.54 | 539 | 28 | 2.43 / 1682.46 | 2 | 5 |
7 | 13 | 88.24 | 5 | 10.59 | 490 | 26 | 2.46 / 1682.49 | 2 | 4 |
8 | 13 | 64.28 | 5 | 10.68 | 454 | 24 | 2.48 / 1682.51 | 2 | 5 |
9 | 13 | 14.20 | 36 | 10.72 | 369 | 142 | 2.63 / 1682.65 | 2 | 5 |
10 | 13 | 3.16 | 36 | 10.75 | 352 | 136 | 2.76 / 1682.79 | 2 | 7 |
11 | 8 | 0.12 | 190 | 10.78 | 339 | 694 | 3.46 / 1683.48 | 2 | 18 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 31 | 10.58 | 504 | 165 | 0.17 / 1676.57 | 2 | 4 |
2 | 3 | 1038.20 | 1 | 9.11 | 1830 | 17 | 0.18 / 1676.59 | 2 | 2 |
3 | 12 | 1144.36 | 114 | 8.63 | 1957 | 1925 | 2.11 / 1678.51 | 2 | 2 |
4 | 7 | 1137.80 | 21 | 8.70 | 1941 | 355 | 2.46 / 1678.87 | 2 | 2 |
5 | 13 | 194.52 | 5 | 10.46 | 636 | 33 | 2.50 / 1678.90 | 2 | 4 |
6 | 13 | 191.64 | 5 | 10.42 | 634 | 33 | 2.53 / 1678.94 | 2 | 4 |
7 | 13 | 71.24 | 5 | 10.66 | 463 | 25 | 2.55 / 1678.96 | 2 | 5 |
8 | 13 | 71.68 | 5 | 10.68 | 466 | 25 | 2.58 / 1678.99 | 2 | 5 |
9 | 13 | 68.28 | 5 | 10.67 | 458 | 24 | 2.60 / 1679.01 | 2 | 5 |
10 | 13 | 60.60 | 5 | 10.68 | 446 | 24 | 2.63 / 1679.03 | 2 | 5 |
11 | 13 | 55.52 | 5 | 10.68 | 444 | 24 | 2.65 / 1679.06 | 2 | 6 |
12 | 13 | 49.96 | 5 | 10.71 | 431 | 23 | 2.67 / 1679.08 | 2 | 5 |
13 | 13 | 41.40 | 5 | 10.71 | 424 | 23 | 2.70 / 1679.10 | 2 | 6 |
14 | 13 | 36.08 | 5 | 10.74 | 413 | 22 | 2.72 / 1679.13 | 2 | 5 |
15 | 13 | 29.60 | 5 | 10.74 | 408 | 22 | 2.74 / 1679.15 | 2 | 7 |
16 | 13 | 28.48 | 5 | 10.74 | 398 | 21 | 2.76 / 1679.17 | 2 | 7 |
17 | 13 | 24.48 | 5 | 10.75 | 399 | 21 | 2.78 / 1679.19 | 2 | 7 |
18 | 13 | 16.76 | 36 | 10.74 | 368 | 142 | 2.92 / 1679.33 | 2 | 6 |
19 | 8 | -0.08 | 190 | 10.79 | 339 | 695 | 3.62 / 1680.03 | 2 | 16 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 32 | 10.60 | 500 | 170 | 0.17 / 1671.59 | 2 | 3 |
2 | 12 | 1109.24 | 5 | 8.82 | 1922 | 85 | 0.25 / 1671.67 | 2 | 2 |
3 | 12 | 2002.92 | 114 | 7.55 | 3143 | 2705 | 2.96 / 1674.38 | 2 | 2 |
4 | 7 | 1987.76 | 21 | 7.53 | 3146 | 497 | 3.46 / 1674.88 | 2 | 2 |
5 | 13 | 1038.04 | 36 | 9.00 | 1825 | 591 | 4.05 / 1675.47 | 2 | 2 |
6 | 13 | 370.88 | 8 | 10.15 | 899 | 73 | 4.12 / 1675.54 | 2 | 4 |
7 | 13 | 205.04 | 5 | 10.46 | 661 | 35 | 4.16 / 1675.57 | 2 | 4 |
8 | 13 | 125.64 | 5 | 10.61 | 553 | 29 | 4.19 / 1675.60 | 2 | 5 |
9 | 13 | 85.28 | 5 | 10.68 | 496 | 26 | 4.21 / 1675.63 | 2 | 5 |
10 | 13 | 62.20 | 5 | 10.71 | 459 | 25 | 4.24 / 1675.65 | 2 | 5 |
11 | 13 | 51.48 | 5 | 10.74 | 443 | 24 | 4.26 / 1675.68 | 2 | 5 |
12 | 13 | 42.24 | 5 | 10.76 | 430 | 23 | 4.28 / 1675.70 | 2 | 5 |
13 | 8 | 0.12 | 190 | 10.83 | 343 | 706 | 4.99 / 1676.41 | 2 | 11 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 32 | 10.65 | 498 | 170 | 0.17 / 1668.16 | 2 | 4 |
2 | 3 | 955.32 | -1 | 10.65 | 498 | 0 | 0.00 / 1668.16 | 2 | 4 |
3 | 12 | 1119.24 | 114 | 8.80 | 1922 | 1928 | 2.10 / 1670.09 | 2 | 2 |
4 | 7 | 1110.04 | 21 | 8.87 | 1908 | 355 | 2.45 / 1670.44 | 2 | 2 |
5 | 13 | 195.00 | 5 | 10.50 | 638 | 33 | 2.49 / 1670.48 | 2 | 4 |
6 | 13 | 132.04 | 5 | 10.62 | 550 | 29 | 2.52 / 1670.51 | 2 | 4 |
7 | 13 | 89.16 | 5 | 10.67 | 489 | 26 | 2.54 / 1670.53 | 2 | 4 |
8 | 13 | 64.24 | 5 | 10.74 | 458 | 25 | 2.57 / 1670.56 | 2 | 5 |
9 | 13 | 51.76 | 5 | 10.75 | 441 | 24 | 2.59 / 1670.58 | 2 | 5 |
10 | 13 | 15.20 | 36 | 10.77 | 368 | 143 | 2.73 / 1670.72 | 2 | 4 |
11 | 8 | 0.04 | 190 | 10.83 | 338 | 696 | 3.43 / 1671.42 | 2 | 21 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 33 | 10.66 | 484 | 170 | 0.17 / 1664.68 | 2 | 3 |
2 | 3 | 946.44 | -1 | 10.66 | 484 | 0 | 0.00 / 1664.68 | 2 | 3 |
3 | 12 | 1120.56 | 114 | 8.84 | 1920 | 1935 | 2.11 / 1666.62 | 2 | 2 |
4 | 7 | 1113.76 | 21 | 8.92 | 1914 | 359 | 2.46 / 1666.98 | 2 | 2 |
5 | 13 | 188.08 | 5 | 10.55 | 629 | 33 | 2.50 / 1667.01 | 2 | 4 |
6 | 13 | 120.64 | 5 | 10.64 | 533 | 28 | 2.53 / 1667.04 | 2 | 4 |
7 | 13 | 88.84 | 5 | 10.69 | 489 | 26 | 2.55 / 1667.06 | 2 | 4 |
8 | 13 | 70.04 | 5 | 10.74 | 464 | 25 | 2.58 / 1667.09 | 2 | 4 |
9 | 13 | 55.52 | 5 | 10.76 | 446 | 24 | 2.60 / 1667.11 | 2 | 5 |
10 | 13 | 49.16 | 5 | 10.76 | 434 | 23 | 2.62 / 1667.14 | 2 | 5 |
11 | 13 | 44.24 | 5 | 10.79 | 423 | 23 | 2.65 / 1667.16 | 2 | 5 |
12 | 13 | 9.24 | 36 | 10.79 | 362 | 141 | 2.79 / 1667.30 | 2 | 8 |
13 | 8 | 0.24 | 190 | 10.84 | 335 | 690 | 3.48 / 1667.99 | 2 | 17 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 33 | 10.73 | 491 | 174 | 0.17 / 1661.07 | 2 | 3 |
2 | 12 | 1123.20 | 114 | 8.90 | 1928 | 1956 | 2.13 / 1663.02 | 2 | 2 |
3 | 7 | 1116.04 | 21 | 8.96 | 1917 | 361 | 2.49 / 1663.38 | 2 | 2 |
4 | 13 | 187.84 | 5 | 10.54 | 634 | 33 | 2.52 / 1663.42 | 2 | 5 |
5 | 13 | 109.72 | 5 | 10.67 | 519 | 28 | 2.55 / 1663.44 | 2 | 5 |
6 | 13 | 75.24 | 5 | 10.73 | 473 | 25 | 2.58 / 1663.47 | 2 | 5 |
7 | 13 | 58.48 | 5 | 10.77 | 448 | 24 | 2.60 / 1663.49 | 2 | 5 |
8 | 13 | 50.56 | 5 | 10.78 | 436 | 24 | 2.62 / 1663.52 | 2 | 5 |
9 | 13 | 41.12 | 5 | 10.79 | 421 | 23 | 2.65 / 1663.54 | 2 | 5 |
10 | 13 | 16.76 | 36 | 10.80 | 370 | 144 | 2.79 / 1663.68 | 2 | 5 |
11 | 13 | 4.96 | 36 | 10.84 | 348 | 136 | 2.93 / 1663.82 | 2 | 6 |
12 | 8 | 0.04 | 190 | 10.85 | 337 | 695 | 3.62 / 1664.51 | 2 | 14 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 33 | 10.70 | 486 | 172 | 0.17 / 1655.95 | 2 | 3 |
2 | 3 | 957.84 | -1 | 10.70 | 486 | 0 | 0.00 / 1655.95 | 2 | 3 |
3 | 12 | 1135.64 | 5 | 9.09 | 1957 | 89 | 0.26 / 1656.04 | 2 | 2 |
4 | 12 | 2000.72 | 114 | 7.93 | 3148 | 2846 | 3.11 / 1658.89 | 2 | 2 |
5 | 7 | 1983.96 | 20 | 7.97 | 3138 | 500 | 3.61 / 1659.39 | 2 | 2 |
6 | 13 | 1037.80 | 36 | 9.24 | 1824 | 607 | 4.21 / 1660.00 | 2 | 2 |
7 | 13 | 324.00 | 7 | 10.35 | 829 | 60 | 4.27 / 1660.06 | 2 | 4 |
8 | 13 | 177.24 | 5 | 10.60 | 622 | 33 | 4.31 / 1660.09 | 2 | 4 |
9 | 13 | 106.00 | 5 | 10.75 | 520 | 28 | 4.33 / 1660.12 | 2 | 5 |
10 | 13 | 54.48 | 5 | 10.80 | 446 | 24 | 4.36 / 1660.14 | 2 | 5 |
11 | 13 | 47.40 | 5 | 10.83 | 437 | 24 | 4.38 / 1660.16 | 2 | 5 |
12 | 13 | 43.76 | 5 | 10.83 | 426 | 23 | 4.41 / 1660.19 | 2 | 5 |
13 | 8 | 0.16 | 190 | 10.89 | 340 | 703 | 5.11 / 1660.89 | 2 | 11 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 33 | 10.71 | 493 | 174 | 0.17 / 1652.46 | 2 | 3 |
2 | 3 | 971.56 | -1 | 10.71 | 493 | 0 | 0.00 / 1652.46 | 2 | 3 |
3 | 3 | 1021.64 | 1 | 9.50 | 1809 | 17 | 0.19 / 1652.48 | 2 | 2 |
4 | 12 | 1147.44 | 114 | 8.97 | 1958 | 2002 | 2.19 / 1654.48 | 2 | 2 |
5 | 7 | 1139.44 | 21 | 9.03 | 1957 | 371 | 2.56 / 1654.85 | 2 | 2 |
6 | 13 | 380.04 | 8 | 10.26 | 898 | 74 | 2.64 / 1654.92 | 2 | 4 |
7 | 13 | 108.44 | 5 | 10.72 | 516 | 28 | 2.67 / 1654.95 | 2 | 5 |
8 | 13 | 15.40 | 36 | 10.84 | 363 | 142 | 2.81 / 1655.09 | 2 | 4 |
9 | 8 | 0.40 | 190 | 10.88 | 334 | 690 | 3.50 / 1655.78 | 2 | 10 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 33 | 10.71 | 492 | 174 | 0.17 / 1649.02 | 2 | 3 |
2 | 3 | 949.28 | -1 | 10.71 | 492 | 0 | 0.00 / 1649.02 | 2 | 3 |
3 | 12 | 1136.60 | 114 | 9.01 | 1948 | 2001 | 2.17 / 1651.03 | 2 | 2 |
4 | 7 | 1128.68 | 21 | 9.09 | 1932 | 369 | 2.54 / 1651.39 | 2 | 2 |
5 | 13 | 363.12 | 8 | 10.31 | 883 | 73 | 2.62 / 1651.47 | 2 | 4 |
6 | 13 | 108.72 | 5 | 10.73 | 522 | 28 | 2.64 / 1651.50 | 2 | 5 |
7 | 13 | 75.92 | 5 | 10.78 | 471 | 25 | 2.67 / 1651.52 | 2 | 5 |
8 | 13 | 58.56 | 5 | 10.79 | 441 | 24 | 2.69 / 1651.54 | 2 | 5 |
9 | 13 | 49.48 | 5 | 10.83 | 432 | 23 | 2.72 / 1651.57 | 2 | 5 |
10 | 13 | 41.24 | 5 | 10.85 | 418 | 23 | 2.74 / 1651.59 | 2 | 5 |
11 | 8 | 0.08 | 190 | 10.90 | 335 | 694 | 3.43 / 1652.28 | 2 | 12 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 33 | 10.77 | 487 | 173 | 0.17 / 1645.51 | 2 | 3 |
2 | 12 | 1139.76 | 114 | 9.07 | 1951 | 2017 | 2.19 / 1647.53 | 2 | 2 |
3 | 7 | 1132.32 | 21 | 9.13 | 1943 | 373 | 2.56 / 1647.90 | 2 | 2 |
4 | 13 | 109.68 | 5 | 10.77 | 512 | 28 | 2.59 / 1647.93 | 2 | 5 |
5 | 13 | 76.76 | 5 | 10.81 | 467 | 25 | 2.62 / 1647.95 | 2 | 5 |
6 | 13 | 58.84 | 5 | 10.83 | 445 | 24 | 2.64 / 1647.98 | 2 | 5 |
7 | 13 | 49.64 | 5 | 10.86 | 429 | 23 | 2.66 / 1648.00 | 2 | 5 |
8 | 13 | 44.76 | 5 | 10.87 | 420 | 23 | 2.69 / 1648.02 | 2 | 5 |
9 | 13 | 14.40 | 36 | 10.88 | 359 | 141 | 2.83 / 1648.16 | 2 | 5 |
10 | 8 | -0.16 | 190 | 10.91 | 332 | 688 | 3.51 / 1648.85 | 2 | 15 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 33 | 10.78 | 486 | 173 | 0.17 / 1640.35 | 2 | 3 |
2 | 12 | 1102.68 | 5 | 9.33 | 1919 | 90 | 0.26 / 1640.44 | 2 | 2 |
3 | 12 | 2000.24 | 114 | 8.22 | 3152 | 2954 | 3.22 / 1643.40 | 2 | 2 |
4 | 7 | 1980.48 | 21 | 8.30 | 3125 | 545 | 3.76 / 1643.94 | 2 | 2 |
5 | 13 | 964.44 | 36 | 9.52 | 1735 | 595 | 4.36 / 1644.54 | 2 | 2 |
6 | 13 | 220.28 | 5 | 10.62 | 689 | 37 | 4.39 / 1644.57 | 2 | 4 |
7 | 13 | 142.04 | 5 | 10.74 | 571 | 31 | 4.42 / 1644.60 | 2 | 5 |
8 | 13 | 88.48 | 5 | 10.81 | 496 | 27 | 4.45 / 1644.63 | 2 | 5 |
9 | 8 | 0.28 | 190 | 10.94 | 340 | 707 | 5.16 / 1645.34 | 2 | 13 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 33 | 10.76 | 493 | 175 | 0.18 / 1636.85 | 2 | 3 |
2 | 12 | 1131.24 | 114 | 9.15 | 1944 | 2028 | 2.20 / 1638.88 | 2 | 2 |
3 | 7 | 1123.76 | 21 | 9.25 | 1932 | 375 | 2.58 / 1639.25 | 2 | 2 |
4 | 13 | 193.96 | 5 | 10.65 | 638 | 34 | 2.61 / 1639.29 | 2 | 5 |
5 | 13 | 112.80 | 5 | 10.76 | 523 | 28 | 2.64 / 1639.32 | 2 | 5 |
6 | 13 | 47.12 | 5 | 10.88 | 423 | 23 | 2.66 / 1639.34 | 2 | 5 |
7 | 13 | 16.64 | 36 | 10.88 | 362 | 142 | 2.81 / 1639.48 | 2 | 5 |
8 | 8 | 0.08 | 190 | 10.92 | 337 | 699 | 3.50 / 1640.18 | 2 | 15 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 34 | 10.79 | 475 | 174 | 0.17 / 1633.41 | 2 | 3 |
2 | 3 | 972.80 | -1 | 10.79 | 475 | 0 | 0.00 / 1633.41 | 2 | 3 |
3 | 3 | 1029.20 | 1 | 9.76 | 1829 | 18 | 0.19 / 1633.43 | 2 | 2 |
4 | 12 | 1124.96 | 114 | 9.19 | 1933 | 2025 | 2.22 / 1635.45 | 2 | 2 |
5 | 7 | 1114.92 | 21 | 9.27 | 1922 | 374 | 2.59 / 1635.83 | 2 | 2 |
6 | 13 | 118.12 | 5 | 10.79 | 535 | 29 | 2.62 / 1635.86 | 2 | 5 |
7 | 13 | 84.64 | 5 | 10.82 | 482 | 26 | 2.65 / 1635.88 | 2 | 5 |
8 | 13 | 64.36 | 5 | 10.86 | 449 | 24 | 2.67 / 1635.91 | 2 | 5 |
9 | 13 | 52.60 | 5 | 10.88 | 432 | 24 | 2.69 / 1635.93 | 2 | 5 |
10 | 13 | 46.84 | 5 | 10.88 | 425 | 23 | 2.72 / 1635.95 | 2 | 5 |
11 | 13 | 43.84 | 5 | 10.90 | 413 | 23 | 2.74 / 1635.98 | 2 | 5 |
12 | 8 | 0.28 | 190 | 10.93 | 337 | 700 | 3.44 / 1636.68 | 2 | 14 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 34 | 10.85 | 485 | 179 | 0.18 / 1630.01 | 2 | 2 |
2 | 12 | 1116.92 | 114 | 9.24 | 1925 | 2028 | 2.21 / 1632.04 | 2 | 2 |
3 | 7 | 1107.28 | 21 | 9.33 | 1912 | 375 | 2.58 / 1632.42 | 2 | 2 |
4 | 13 | 97.76 | 5 | 10.83 | 503 | 27 | 2.61 / 1632.44 | 2 | 5 |
5 | 13 | 68.84 | 5 | 10.87 | 457 | 25 | 2.63 / 1632.47 | 2 | 5 |
6 | 13 | 57.84 | 5 | 10.89 | 440 | 24 | 2.66 / 1632.49 | 2 | 5 |
7 | 13 | 49.48 | 5 | 10.91 | 431 | 24 | 2.68 / 1632.52 | 2 | 5 |
8 | 13 | 44.88 | 5 | 10.91 | 419 | 23 | 2.70 / 1632.54 | 2 | 6 |
9 | 8 | -0.04 | 190 | 10.94 | 335 | 696 | 3.40 / 1633.24 | 2 | 9 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 33 | 10.80 | 490 | 175 | 0.17 / 1624.81 | 2 | 2 |
2 | 12 | 1122.16 | 5 | 9.49 | 1943 | 92 | 0.27 / 1624.90 | 2 | 2 |
3 | 12 | 2002.88 | 114 | 8.44 | 3168 | 3048 | 3.31 / 1627.95 | 2 | 2 |
4 | 7 | 1984.72 | 21 | 8.54 | 3144 | 564 | 3.88 / 1628.52 | 2 | 2 |
5 | 13 | 739.20 | 36 | 9.95 | 1417 | 508 | 4.39 / 1629.02 | 2 | 3 |
6 | 13 | 133.60 | 5 | 10.80 | 559 | 30 | 4.42 / 1629.05 | 2 | 5 |
7 | 13 | 89.84 | 5 | 10.88 | 496 | 27 | 4.44 / 1629.08 | 2 | 6 |
8 | 13 | 63.48 | 5 | 10.92 | 457 | 25 | 4.47 / 1629.11 | 2 | 6 |
9 | 13 | 51.00 | 5 | 10.95 | 437 | 24 | 4.49 / 1629.13 | 2 | 6 |
10 | 8 | 0.00 | 190 | 10.97 | 339 | 707 | 5.20 / 1629.84 | 2 | 14 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 33 | 10.84 | 466 | 167 | 0.17 / 1621.40 | 2 | 2 |
2 | 12 | 1116.92 | 114 | 9.31 | 1918 | 2036 | 2.20 / 1623.44 | 2 | 2 |
3 | 7 | 1106.52 | 21 | 9.40 | 1909 | 377 | 2.58 / 1623.82 | 2 | 2 |
4 | 13 | 105.00 | 5 | 10.82 | 510 | 28 | 2.61 / 1623.84 | 2 | 5 |
5 | 13 | 72.60 | 5 | 10.89 | 460 | 25 | 2.63 / 1623.87 | 2 | 5 |
6 | 13 | 64.28 | 5 | 10.87 | 450 | 24 | 2.66 / 1623.89 | 2 | 5 |
7 | 13 | 54.96 | 5 | 10.90 | 436 | 24 | 2.68 / 1623.92 | 2 | 5 |
8 | 13 | 47.56 | 5 | 10.92 | 427 | 23 | 2.70 / 1623.94 | 2 | 5 |
9 | 8 | 0.84 | 190 | 10.96 | 335 | 698 | 3.40 / 1624.64 | 2 | 22 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 33 | 10.83 | 473 | 169 | 0.17 / 1617.89 | 2 | 2 |
2 | 12 | 1117.04 | 114 | 9.33 | 1922 | 2044 | 2.21 / 1619.94 | 2 | 2 |
3 | 7 | 1107.04 | 21 | 9.42 | 1911 | 378 | 2.59 / 1620.31 | 2 | 2 |
4 | 13 | 177.56 | 5 | 10.73 | 625 | 34 | 2.62 / 1620.35 | 2 | 5 |
5 | 13 | 111.96 | 5 | 10.83 | 526 | 28 | 2.65 / 1620.38 | 2 | 5 |
6 | 13 | 73.32 | 5 | 10.88 | 461 | 25 | 2.68 / 1620.40 | 2 | 5 |
7 | 13 | 2.56 | 36 | 10.96 | 344 | 136 | 2.81 / 1620.54 | 2 | 7 |
8 | 8 | 0.16 | 190 | 10.96 | 336 | 700 | 3.51 / 1621.24 | 2 | 15 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 33 | 10.90 | 468 | 168 | 0.17 / 1614.55 | 2 | 2 |
2 | 12 | 1099.96 | 114 | 9.38 | 1903 | 2035 | 2.20 / 1616.58 | 2 | 2 |
3 | 7 | 1091.48 | 20 | 9.43 | 1906 | 359 | 2.56 / 1616.94 | 2 | 2 |
4 | 13 | 94.12 | 5 | 10.86 | 491 | 27 | 2.59 / 1616.97 | 2 | 5 |
5 | 13 | 70.04 | 5 | 10.90 | 458 | 25 | 2.61 / 1616.99 | 2 | 5 |
6 | 13 | 54.48 | 5 | 10.93 | 437 | 24 | 2.64 / 1617.02 | 2 | 5 |
7 | 8 | 0.68 | 190 | 10.96 | 338 | 704 | 3.34 / 1617.72 | 2 | 14 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 33 | 10.84 | 470 | 168 | 0.17 / 1609.18 | 2 | 2 |
2 | 12 | 1100.96 | 5 | 9.53 | 1922 | 92 | 0.26 / 1609.27 | 2 | 2 |
3 | 12 | 2003.72 | 114 | 8.62 | 3177 | 3122 | 3.38 / 1612.39 | 2 | 2 |
4 | 7 | 1986.20 | 21 | 8.66 | 3165 | 576 | 3.96 / 1612.97 | 2 | 2 |
5 | 13 | 707.00 | 36 | 10.07 | 1379 | 500 | 4.46 / 1613.46 | 2 | 3 |
6 | 13 | 112.20 | 5 | 10.88 | 533 | 29 | 4.49 / 1613.49 | 2 | 5 |
7 | 13 | 73.84 | 5 | 10.93 | 476 | 26 | 4.51 / 1613.52 | 2 | 5 |
8 | 13 | 15.88 | 36 | 10.97 | 370 | 146 | 4.66 / 1613.67 | 2 | 6 |
9 | 8 | -0.04 | 190 | 10.99 | 342 | 714 | 5.37 / 1614.38 | 2 | 17 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 33 | 10.87 | 472 | 169 | 0.17 / 1605.66 | 2 | 2 |
2 | 12 | 1112.68 | 114 | 9.41 | 1919 | 2059 | 2.23 / 1607.72 | 2 | 2 |
3 | 7 | 1103.16 | 20 | 9.51 | 1914 | 364 | 2.59 / 1608.08 | 2 | 2 |
4 | 13 | 165.88 | 5 | 10.78 | 604 | 33 | 2.62 / 1608.11 | 2 | 5 |
5 | 13 | 109.36 | 5 | 10.85 | 518 | 28 | 2.65 / 1608.14 | 2 | 5 |
6 | 13 | 72.28 | 5 | 10.89 | 467 | 25 | 2.68 / 1608.17 | 2 | 5 |
7 | 13 | 15.68 | 36 | 10.94 | 360 | 142 | 2.82 / 1608.31 | 2 | 5 |
8 | 8 | 0.24 | 190 | 10.97 | 336 | 700 | 3.52 / 1609.01 | 2 | 15 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 33 | 10.89 | 474 | 170 | 0.17 / 1602.12 | 2 | 2 |
2 | 12 | 1130.76 | 114 | 9.42 | 1950 | 2094 | 2.26 / 1604.21 | 2 | 2 |
3 | 7 | 1122.00 | 21 | 9.51 | 1931 | 386 | 2.65 / 1604.60 | 2 | 2 |
4 | 13 | 154.60 | 5 | 10.82 | 585 | 32 | 2.68 / 1604.63 | 2 | 5 |
5 | 13 | 63.04 | 5 | 10.94 | 450 | 25 | 2.71 / 1604.65 | 2 | 5 |
6 | 13 | 4.32 | 36 | 10.97 | 352 | 139 | 2.85 / 1604.79 | 2 | 6 |
7 | 8 | 0.24 | 190 | 10.98 | 334 | 697 | 3.54 / 1605.49 | 2 | 14 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 32 | 10.91 | 470 | 164 | 0.16 / 1598.66 | 2 | 2 |
2 | 3 | 1020.72 | 1 | 10.02 | 1830 | 18 | 0.18 / 1598.68 | 2 | 2 |
3 | 12 | 1125.68 | 114 | 9.45 | 1945 | 2095 | 2.28 / 1600.77 | 2 | 2 |
4 | 7 | 1113.60 | 20 | 9.53 | 1929 | 368 | 2.65 / 1601.14 | 2 | 2 |
5 | 13 | 92.16 | 5 | 10.89 | 498 | 27 | 2.67 / 1601.17 | 2 | 5 |
6 | 13 | 68.40 | 5 | 10.93 | 462 | 25 | 2.70 / 1601.19 | 2 | 5 |
7 | 13 | 54.80 | 5 | 10.96 | 441 | 24 | 2.72 / 1601.22 | 2 | 5 |
8 | 13 | 47.36 | 5 | 10.95 | 428 | 23 | 2.75 / 1601.24 | 2 | 6 |
9 | 8 | -0.08 | 190 | 10.98 | 338 | 705 | 3.45 / 1601.95 | 2 | 13 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 33 | 10.89 | 466 | 167 | 0.17 / 1593.40 | 2 | 2 |
2 | 12 | 1116.96 | 5 | 9.60 | 1954 | 94 | 0.26 / 1593.50 | 2 | 2 |
3 | 12 | 2002.60 | 114 | 8.79 | 3173 | 3180 | 3.44 / 1596.68 | 2 | 2 |
4 | 7 | 1983.28 | 21 | 8.89 | 3142 | 587 | 4.03 / 1597.26 | 2 | 2 |
5 | 13 | 712.80 | 36 | 10.14 | 1379 | 503 | 4.53 / 1597.77 | 2 | 4 |
6 | 13 | 74.64 | 5 | 10.97 | 465 | 26 | 4.56 / 1597.79 | 2 | 5 |
7 | 8 | 0.08 | 190 | 11.02 | 336 | 704 | 5.26 / 1598.49 | 2 | 14 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 33 | 10.88 | 477 | 171 | 0.17 / 1589.88 | 2 | 3 |
2 | 3 | 969.60 | -1 | 10.88 | 477 | 0 | 0.00 / 1589.88 | 2 | 3 |
3 | 3 | 1022.16 | 1 | 10.02 | 1807 | 18 | 0.19 / 1589.89 | 2 | 2 |
4 | 12 | 1118.96 | 114 | 9.50 | 1927 | 2087 | 2.28 / 1591.98 | 2 | 2 |
5 | 7 | 1108.52 | 21 | 9.60 | 1909 | 385 | 2.66 / 1592.37 | 2 | 2 |
6 | 13 | 92.40 | 36 | 10.87 | 458 | 179 | 2.84 / 1592.55 | 2 | 5 |
7 | 8 | 0.36 | 190 | 11.00 | 330 | 690 | 3.53 / 1593.24 | 2 | 16 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 34 | 10.91 | 459 | 170 | 0.17 / 1586.32 | 2 | 2 |
2 | 3 | 949.36 | -1 | 10.91 | 459 | 0 | 0.00 / 1586.32 | 2 | 2 |
3 | 12 | 1133.88 | 114 | 9.50 | 1952 | 2114 | 2.28 / 1588.43 | 2 | 2 |
4 | 7 | 1123.92 | 20 | 9.59 | 1941 | 372 | 2.66 / 1588.80 | 2 | 2 |
5 | 13 | 143.16 | 36 | 10.81 | 533 | 207 | 2.86 / 1589.01 | 2 | 5 |
6 | 8 | 0.28 | 190 | 11.00 | 333 | 696 | 3.56 / 1589.71 | 2 | 14 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 32 | 10.92 | 484 | 169 | 0.17 / 1582.58 | 2 | 2 |
2 | 3 | 1042.68 | 1 | 10.05 | 1840 | 18 | 0.19 / 1582.60 | 2 | 2 |
3 | 3 | 1022.00 | 1 | 10.07 | 1829 | 18 | 0.21 / 1582.62 | 2 | 2 |
4 | 12 | 1128.84 | 114 | 9.53 | 1945 | 2113 | 2.32 / 1584.73 | 2 | 2 |
5 | 7 | 1117.64 | 21 | 9.62 | 1934 | 391 | 2.71 / 1585.12 | 2 | 2 |
6 | 13 | 83.80 | 36 | 10.90 | 452 | 177 | 2.89 / 1585.30 | 2 | 5 |
7 | 13 | 20.56 | 36 | 10.98 | 362 | 143 | 3.03 / 1585.44 | 2 | 5 |
8 | 8 | 0.56 | 190 | 11.01 | 335 | 701 | 3.73 / 1586.15 | 2 | 15 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 32 | 10.91 | 476 | 166 | 0.17 / 1577.38 | 2 | 2 |
2 | 3 | 1022.08 | 1 | 10.05 | 1810 | 18 | 0.18 / 1577.39 | 2 | 2 |
3 | 12 | 1117.44 | 5 | 9.72 | 1947 | 95 | 0.28 / 1577.49 | 2 | 2 |
4 | 12 | 2000.80 | 114 | 8.92 | 3178 | 3232 | 3.51 / 1580.72 | 2 | 2 |
5 | 7 | 1980.84 | 20 | 9.00 | 3161 | 569 | 4.08 / 1581.29 | 2 | 2 |
6 | 13 | 498.84 | 36 | 10.43 | 1079 | 405 | 4.48 / 1581.70 | 2 | 4 |
7 | 8 | 0.20 | 190 | 11.03 | 343 | 719 | 5.20 / 1582.41 | 2 | 10 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 33 | 10.90 | 479 | 172 | 0.17 / 1573.76 | 2 | 2 |
2 | 3 | 1023.40 | 1 | 10.06 | 1839 | 19 | 0.19 / 1573.78 | 2 | 2 |
3 | 12 | 1123.48 | 114 | 9.57 | 1941 | 2118 | 2.31 / 1575.90 | 2 | 2 |
4 | 7 | 1112.24 | 21 | 9.70 | 1926 | 392 | 2.70 / 1576.29 | 2 | 2 |
5 | 13 | 151.56 | 5 | 10.86 | 586 | 32 | 2.73 / 1576.32 | 2 | 6 |
6 | 13 | 99.12 | 5 | 10.90 | 509 | 28 | 2.76 / 1576.35 | 2 | 6 |
7 | 13 | 66.96 | 5 | 10.96 | 464 | 25 | 2.79 / 1576.37 | 2 | 6 |
8 | 13 | 1.44 | 36 | 11.03 | 341 | 135 | 2.92 / 1576.51 | 2 | 7 |
9 | 8 | -0.08 | 190 | 11.01 | 335 | 701 | 3.62 / 1577.21 | 2 | 16 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 31 | 10.90 | 483 | 163 | 0.16 / 1570.29 | 2 | 3 |
2 | 3 | 1020.24 | 1 | 10.06 | 1824 | 18 | 0.18 / 1570.31 | 2 | 2 |
3 | 12 | 1136.92 | 114 | 9.57 | 1958 | 2136 | 2.32 / 1572.44 | 2 | 2 |
4 | 7 | 1125.40 | 20 | 9.69 | 1952 | 378 | 2.70 / 1572.82 | 2 | 2 |
5 | 13 | 94.52 | 5 | 10.94 | 500 | 27 | 2.72 / 1572.85 | 2 | 5 |
6 | 13 | 66.28 | 5 | 10.96 | 460 | 25 | 2.75 / 1572.88 | 2 | 5 |
7 | 8 | 0.36 | 190 | 11.01 | 341 | 713 | 3.46 / 1573.59 | 2 | 11 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 32 | 10.93 | 491 | 172 | 0.17 / 1566.66 | 2 | 3 |
2 | 3 | 963.12 | -1 | 10.93 | 491 | 0 | 0.00 / 1566.66 | 2 | 3 |
3 | 12 | 1127.08 | 114 | 9.59 | 1953 | 2135 | 2.31 / 1568.79 | 2 | 2 |
4 | 7 | 1117.20 | 21 | 9.70 | 1931 | 393 | 2.70 / 1569.19 | 2 | 3 |
5 | 13 | 104.28 | 5 | 10.92 | 518 | 28 | 2.73 / 1569.22 | 2 | 6 |
6 | 13 | 45.40 | 5 | 10.99 | 429 | 24 | 2.75 / 1569.24 | 2 | 6 |
7 | 13 | 42.32 | 5 | 10.99 | 424 | 23 | 2.78 / 1569.26 | 2 | 6 |
8 | 13 | 15.76 | 36 | 10.98 | 371 | 147 | 2.92 / 1569.41 | 2 | 7 |
9 | 8 | -0.20 | 190 | 11.01 | 343 | 718 | 3.64 / 1570.13 | 2 | 13 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 32 | 10.88 | 496 | 173 | 0.17 / 1561.15 | 2 | 3 |
2 | 12 | 1105.36 | 5 | 9.82 | 1950 | 96 | 0.27 / 1561.25 | 2 | 2 |
3 | 12 | 2003.04 | 114 | 9.02 | 3182 | 3272 | 3.54 / 1564.52 | 2 | 2 |
4 | 7 | 1982.84 | 21 | 9.11 | 3158 | 604 | 4.14 / 1565.12 | 2 | 2 |
5 | 13 | 675.48 | 36 | 10.29 | 1331 | 493 | 4.64 / 1565.62 | 2 | 4 |
6 | 13 | 16.60 | 36 | 11.02 | 371 | 147 | 4.78 / 1565.76 | 2 | 6 |
7 | 8 | 0.08 | 190 | 11.03 | 345 | 723 | 5.51 / 1566.49 | 2 | 16 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 32 | 10.87 | 497 | 173 | 0.17 / 1557.47 | 2 | 3 |
2 | 3 | 1028.56 | 1 | 10.07 | 1855 | 19 | 0.19 / 1557.49 | 2 | 2 |
3 | 12 | 1154.84 | 114 | 9.59 | 1992 | 2178 | 2.37 / 1559.67 | 2 | 2 |
4 | 7 | 1147.12 | 21 | 9.71 | 1974 | 403 | 2.77 / 1560.07 | 2 | 3 |
5 | 13 | 95.20 | 5 | 10.96 | 500 | 27 | 2.80 / 1560.10 | 2 | 6 |
6 | 13 | 67.68 | 5 | 10.97 | 463 | 25 | 2.82 / 1560.12 | 2 | 6 |
7 | 13 | 15.72 | 36 | 10.99 | 365 | 144 | 2.97 / 1560.27 | 2 | 6 |
8 | 8 | 0.24 | 190 | 11.01 | 341 | 713 | 3.68 / 1560.98 | 2 | 14 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 32 | 10.89 | 488 | 170 | 0.17 / 1553.96 | 2 | 3 |
2 | 12 | 1129.08 | 114 | 9.63 | 1952 | 2143 | 2.31 / 1556.10 | 2 | 2 |
3 | 7 | 1119.24 | 21 | 9.76 | 1942 | 398 | 2.71 / 1556.50 | 2 | 3 |
4 | 13 | 87.80 | 5 | 10.97 | 491 | 27 | 2.74 / 1556.53 | 2 | 6 |
5 | 13 | 65.56 | 5 | 10.99 | 460 | 25 | 2.76 / 1556.55 | 2 | 6 |
6 | 13 | 53.80 | 5 | 10.99 | 443 | 24 | 2.79 / 1556.58 | 2 | 6 |
7 | 8 | 0.00 | 190 | 11.01 | 344 | 720 | 3.51 / 1557.30 | 2 | 16 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 32 | 10.91 | 491 | 171 | 0.17 / 1550.47 | 2 | 3 |
2 | 12 | 1112.80 | 114 | 9.66 | 1930 | 2125 | 2.30 / 1552.59 | 2 | 2 |
3 | 7 | 1102.16 | 21 | 9.79 | 1918 | 394 | 2.69 / 1552.99 | 2 | 3 |
4 | 13 | 83.52 | 5 | 10.96 | 491 | 27 | 2.72 / 1553.01 | 2 | 6 |
5 | 13 | 62.72 | 5 | 10.99 | 459 | 25 | 2.74 / 1553.04 | 2 | 6 |
6 | 13 | 51.20 | 5 | 11.00 | 442 | 24 | 2.77 / 1553.06 | 2 | 6 |
7 | 8 | 0.56 | 190 | 11.01 | 347 | 726 | 3.49 / 1553.79 | 2 | 16 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 32 | 10.88 | 486 | 169 | 0.17 / 1545.20 | 2 | 3 |
2 | 12 | 1104.96 | 5 | 9.85 | 1942 | 96 | 0.26 / 1545.29 | 2 | 2 |
3 | 12 | 2003.32 | 114 | 9.05 | 3185 | 3286 | 3.55 / 1548.58 | 2 | 2 |
4 | 7 | 1983.08 | 21 | 9.20 | 3159 | 610 | 4.16 / 1549.19 | 2 | 2 |
5 | 13 | 426.04 | 36 | 10.57 | 960 | 365 | 4.53 / 1549.55 | 2 | 5 |
6 | 13 | 66.08 | 5 | 11.02 | 462 | 25 | 4.55 / 1549.58 | 2 | 6 |
7 | 8 | -0.04 | 190 | 11.03 | 342 | 717 | 5.27 / 1550.30 | 2 | 12 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 31 | 10.89 | 492 | 166 | 0.17 / 1541.68 | 2 | 3 |
2 | 3 | 1021.00 | 1 | 10.14 | 1824 | 18 | 0.18 / 1541.70 | 2 | 2 |
3 | 12 | 1127.04 | 114 | 9.66 | 1946 | 2143 | 2.33 / 1543.84 | 2 | 2 |
4 | 7 | 1117.00 | 21 | 9.79 | 1936 | 398 | 2.73 / 1544.24 | 2 | 3 |
5 | 13 | 89.52 | 5 | 10.95 | 492 | 27 | 2.75 / 1544.27 | 2 | 6 |
6 | 13 | 63.60 | 5 | 10.99 | 456 | 25 | 2.78 / 1544.29 | 2 | 6 |
7 | 13 | 51.28 | 5 | 11.00 | 440 | 24 | 2.80 / 1544.32 | 2 | 6 |
8 | 8 | 0.08 | 190 | 11.01 | 339 | 709 | 3.51 / 1545.03 | 2 | 13 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 32 | 10.89 | 493 | 172 | 0.17 / 1538.07 | 2 | 3 |
2 | 12 | 1116.88 | 114 | 9.67 | 1938 | 2136 | 2.31 / 1540.21 | 2 | 2 |
3 | 7 | 1105.20 | 21 | 9.85 | 1919 | 397 | 2.71 / 1540.60 | 2 | 3 |
4 | 13 | 83.52 | 5 | 10.97 | 488 | 27 | 2.73 / 1540.63 | 2 | 6 |
5 | 13 | 61.00 | 5 | 10.98 | 455 | 25 | 2.76 / 1540.65 | 2 | 5 |
6 | 13 | 13.96 | 36 | 11.00 | 364 | 144 | 2.90 / 1540.80 | 2 | 7 |
7 | 8 | 0.08 | 190 | 11.01 | 343 | 718 | 3.62 / 1541.52 | 2 | 15 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 31 | 10.86 | 509 | 171 | 0.17 / 1534.53 | 2 | 4 |
2 | 3 | 1022.32 | 1 | 10.11 | 1834 | 19 | 0.19 / 1534.55 | 2 | 2 |
3 | 12 | 1141.20 | 114 | 9.66 | 1972 | 2172 | 2.36 / 1536.72 | 2 | 2 |
4 | 7 | 1128.68 | 21 | 9.84 | 1950 | 403 | 2.76 / 1537.12 | 2 | 2 |
5 | 13 | 84.24 | 5 | 10.97 | 489 | 27 | 2.79 / 1537.15 | 2 | 6 |
6 | 13 | 60.92 | 5 | 10.97 | 456 | 25 | 2.82 / 1537.18 | 2 | 5 |
7 | 8 | -0.08 | 190 | 11.01 | 345 | 722 | 3.54 / 1537.90 | 2 | 14 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 29 | 10.80 | 495 | 155 | 0.16 / 1529.12 | 2 | 3 |
2 | 3 | 1082.84 | 2 | 9.95 | 1898 | 38 | 0.19 / 1529.16 | 2 | 2 |
3 | 3 | 1036.00 | 1 | 10.00 | 1840 | 18 | 0.21 / 1529.18 | 2 | 2 |
4 | 12 | 1149.24 | 5 | 9.75 | 1980 | 97 | 0.31 / 1529.28 | 2 | 2 |
5 | 12 | 2001.80 | 114 | 9.04 | 3167 | 3264 | 3.57 / 1532.54 | 2 | 2 |
6 | 7 | 1980.12 | 21 | 9.17 | 3149 | 606 | 4.18 / 1533.15 | 2 | 2 |
7 | 13 | 630.60 | 36 | 10.33 | 1261 | 469 | 4.65 / 1533.62 | 2 | 4 |
8 | 13 | 47.36 | 5 | 10.98 | 434 | 24 | 4.67 / 1533.64 | 2 | 5 |
9 | 8 | 0.88 | 190 | 11.01 | 344 | 720 | 5.39 / 1534.36 | 2 | 14 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 28 | 11.04 | 508 | 157 | 0.16 / 1525.60 | 2 | 5 |
2 | 3 | 1078.24 | 2 | 10.46 | 1910 | 40 | 0.20 / 1525.64 | 2 | 2 |
3 | 12 | 1123.72 | 114 | 9.87 | 1949 | 2193 | 2.39 / 1527.83 | 2 | 2 |
4 | 7 | 1111.76 | 21 | 9.87 | 1930 | 400 | 2.79 / 1528.23 | 2 | 2 |
5 | 13 | 140.32 | 5 | 10.85 | 566 | 31 | 2.82 / 1528.26 | 2 | 5 |
6 | 8 | 0.52 | 190 | 10.95 | 341 | 709 | 3.53 / 1528.97 | 2 | 13 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 30 | 11.44 | 509 | 175 | 0.17 / 1521.93 | 2 | 5 |
2 | 3 | 1041.64 | 1 | 11.03 | 1876 | 21 | 0.20 / 1521.95 | 2 | 2 |
3 | 12 | 1112.84 | 114 | 9.68 | 1932 | 2132 | 2.33 / 1524.08 | 2 | 2 |
4 | 7 | 1102.24 | 21 | 9.89 | 1918 | 398 | 2.73 / 1524.48 | 2 | 2 |
5 | 13 | 143.48 | 5 | 11.06 | 575 | 32 | 2.76 / 1524.51 | 2 | 6 |
6 | 13 | 43.80 | 5 | 11.20 | 430 | 24 | 2.78 / 1524.54 | 2 | 6 |
7 | 13 | 40.76 | 5 | 11.18 | 426 | 24 | 2.81 / 1524.56 | 2 | 6 |
8 | 13 | 15.36 | 36 | 11.19 | 372 | 150 | 2.96 / 1524.71 | 2 | 6 |
9 | 8 | 0.12 | 190 | 11.17 | 343 | 728 | 3.68 / 1525.44 | 2 | 15 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 28 | 11.72 | 522 | 171 | 0.17 / 1518.36 | 2 | 6 |
2 | 3 | 1035.40 | 1 | 11.31 | 1880 | 21 | 0.19 / 1518.38 | 2 | 2 |
3 | 12 | 1127.84 | 114 | 9.67 | 1951 | 2151 | 2.34 / 1520.53 | 2 | 2 |
4 | 7 | 1117.92 | 21 | 10.12 | 1948 | 414 | 2.76 / 1520.95 | 2 | 3 |
5 | 13 | 134.40 | 5 | 11.49 | 568 | 33 | 2.79 / 1520.98 | 2 | 6 |
6 | 8 | 0.36 | 190 | 11.54 | 355 | 778 | 3.57 / 1521.76 | 2 | 16 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 28 | 12.16 | 526 | 179 | 0.18 / 1512.82 | 2 | 7 |
2 | 3 | 1041.60 | 1 | 11.61 | 1896 | 22 | 0.20 / 1512.84 | 2 | 2 |
3 | 12 | 1129.92 | 5 | 11.33 | 1996 | 113 | 0.31 / 1512.95 | 2 | 2 |
4 | 12 | 2000.48 | 114 | 9.56 | 3188 | 3474 | 3.79 / 1516.43 | 2 | 2 |
5 | 7 | 1979.84 | 21 | 9.51 | 3172 | 633 | 4.42 / 1517.06 | 2 | 2 |
6 | 13 | 364.80 | 8 | 11.52 | 900 | 83 | 4.51 / 1517.14 | 2 | 6 |
7 | 13 | 189.16 | 5 | 11.70 | 642 | 38 | 4.54 / 1517.18 | 2 | 6 |
8 | 13 | 110.04 | 5 | 11.79 | 538 | 32 | 4.57 / 1517.21 | 2 | 6 |
9 | 13 | 74.00 | 5 | 11.82 | 484 | 29 | 4.60 / 1517.24 | 2 | 6 |
10 | 13 | 14.20 | 36 | 11.89 | 388 | 166 | 4.77 / 1517.41 | 2 | 7 |
11 | 8 | -0.20 | 190 | 11.69 | 351 | 780 | 5.55 / 1518.19 | 2 | 13 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 28 | 12.56 | 516 | 181 | 0.18 / 1509.26 | 2 | 7 |
2 | 12 | 1125.28 | 114 | 9.28 | 1939 | 2051 | 2.23 / 1511.31 | 2 | 2 |
3 | 7 | 1118.08 | 21 | 10.26 | 1947 | 420 | 2.65 / 1511.73 | 2 | 2 |
4 | 13 | 100.28 | 5 | 12.17 | 516 | 31 | 2.68 / 1511.76 | 2 | 6 |
5 | 13 | 73.08 | 5 | 12.16 | 480 | 29 | 2.71 / 1511.79 | 2 | 6 |
6 | 13 | 55.72 | 5 | 12.17 | 457 | 28 | 2.74 / 1511.82 | 2 | 7 |
7 | 8 | 0.24 | 190 | 12.13 | 355 | 818 | 3.56 / 1512.64 | 2 | 17 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 27 | 12.88 | 522 | 182 | 0.18 / 1505.31 | 2 | 6 |
2 | 3 | 1040.84 | 1 | 12.02 | 1915 | 23 | 0.20 / 1505.33 | 2 | 2 |
3 | 12 | 1149.16 | 114 | 9.85 | 1986 | 2230 | 2.43 / 1507.56 | 2 | 2 |
4 | 7 | 1138.16 | 20 | 10.72 | 1987 | 426 | 2.86 / 1507.99 | 2 | 3 |
5 | 13 | 56.96 | 5 | 12.70 | 461 | 29 | 2.89 / 1508.02 | 2 | 7 |
6 | 13 | 48.40 | 5 | 12.73 | 451 | 29 | 2.92 / 1508.05 | 2 | 7 |
7 | 13 | 44.00 | 5 | 12.75 | 442 | 28 | 2.95 / 1508.07 | 2 | 7 |
8 | 13 | 1.48 | 36 | 12.79 | 372 | 171 | 3.12 / 1508.25 | 2 | 7 |
9 | 8 | -0.04 | 190 | 12.38 | 355 | 835 | 3.95 / 1509.08 | 2 | 15 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.64 | 29 | 13.32 | 529 | 204 | 0.20 / 1501.36 | 2 | 7 |
2 | 3 | 961.40 | -1 | 13.32 | 529 | 0 | 0.00 / 1501.36 | 2 | 7 |
3 | 12 | 1109.72 | 114 | 10.27 | 1935 | 2265 | 2.47 / 1503.62 | 2 | 3 |
4 | 7 | 1097.12 | 21 | 10.78 | 1929 | 437 | 2.91 / 1504.06 | 3 | 3 |
5 | 13 | 15.76 | 36 | 12.94 | 406 | 189 | 3.10 / 1504.25 | 2 | 9 |
6 | 8 | 0.04 | 190 | 12.58 | 367 | 877 | 3.97 / 1505.13 | 2 | 18 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 29 | 13.55 | 516 | 203 | 0.20 / 1495.43 | 2 | 7 |
2 | 3 | 970.20 | -1 | 13.55 | 516 | 0 | 0.00 / 1495.43 | 2 | 7 |
3 | 3 | 1024.64 | 1 | 12.10 | 1889 | 23 | 0.23 / 1495.45 | 2 | 2 |
4 | 12 | 1090.36 | 5 | 12.12 | 1961 | 119 | 0.34 / 1495.57 | 2 | 3 |
5 | 12 | 1935.52 | 114 | 10.27 | 3110 | 3641 | 3.99 / 1499.21 | 2 | 2 |
6 | 7 | 1911.56 | 20 | 10.50 | 3099 | 651 | 4.64 / 1499.86 | 2 | 2 |
7 | 13 | 145.84 | 5 | 13.23 | 595 | 39 | 4.68 / 1499.90 | 2 | 9 |
8 | 13 | 88.40 | 5 | 13.30 | 515 | 34 | 4.71 / 1499.94 | 2 | 8 |
9 | 13 | 51.48 | 5 | 13.33 | 468 | 31 | 4.74 / 1499.97 | 2 | 8 |
10 | 13 | 46.60 | 5 | 13.37 | 459 | 31 | 4.77 / 1500.00 | 2 | 8 |
11 | 13 | 43.84 | 5 | 13.37 | 451 | 30 | 4.80 / 1500.03 | 2 | 9 |
12 | 13 | 40.84 | 5 | 13.34 | 447 | 30 | 4.83 / 1500.06 | 2 | 8 |
13 | 13 | 16.36 | 36 | 13.38 | 399 | 192 | 5.02 / 1500.25 | 2 | 8 |
14 | 8 | -0.16 | 190 | 12.98 | 366 | 903 | 5.93 / 1501.15 | 2 | 16 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 29 | 13.69 | 521 | 207 | 0.21 / 1491.42 | 2 | 6 |
2 | 3 | 973.08 | -1 | 13.69 | 521 | 0 | 0.00 / 1491.42 | 2 | 6 |
3 | 3 | 1043.92 | 1 | 12.40 | 1914 | 24 | 0.23 / 1491.45 | 2 | 2 |
4 | 12 | 1167.00 | 114 | 9.28 | 1999 | 2115 | 2.35 / 1493.56 | 2 | 2 |
5 | 7 | 1157.88 | 21 | 10.71 | 2015 | 453 | 2.80 / 1494.02 | 2 | 3 |
6 | 13 | 194.44 | 5 | 13.41 | 668 | 45 | 2.84 / 1494.06 | 2 | 9 |
7 | 13 | 114.88 | 5 | 13.48 | 553 | 37 | 2.88 / 1494.10 | 2 | 9 |
8 | 13 | 16.60 | 36 | 13.67 | 408 | 201 | 3.08 / 1494.30 | 2 | 8 |
9 | 8 | 0.40 | 190 | 13.23 | 370 | 930 | 4.01 / 1495.23 | 2 | 15 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 29 | 13.79 | 527 | 211 | 0.21 / 1487.58 | 2 | 6 |
2 | 12 | 1122.96 | 114 | 9.84 | 1947 | 2184 | 2.39 / 1489.77 | 2 | 2 |
3 | 7 | 1110.36 | 21 | 10.95 | 1946 | 447 | 2.84 / 1490.22 | 2 | 3 |
4 | 13 | 44.08 | 5 | 13.68 | 465 | 32 | 2.87 / 1490.25 | 2 | 8 |
5 | 8 | 0.04 | 190 | 13.43 | 380 | 970 | 3.84 / 1491.22 | 2 | 13 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 29 | 13.90 | 528 | 213 | 0.21 / 1483.63 | 2 | 8 |
2 | 12 | 1127.96 | 114 | 10.24 | 1960 | 2288 | 2.50 / 1485.92 | 2 | 3 |
3 | 7 | 1116.32 | 21 | 11.14 | 1968 | 460 | 2.96 / 1486.38 | 3 | 4 |
4 | 13 | 47.16 | 5 | 13.80 | 464 | 32 | 2.99 / 1486.41 | 2 | 8 |
5 | 8 | 0.16 | 190 | 13.56 | 372 | 958 | 3.95 / 1487.37 | 2 | 12 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 29 | 13.95 | 512 | 207 | 0.21 / 1477.73 | 2 | 6 |
2 | 12 | 1094.76 | 5 | 12.27 | 1955 | 120 | 0.33 / 1477.85 | 2 | 2 |
3 | 12 | 2000.20 | 114 | 10.32 | 3202 | 3767 | 4.09 / 1481.62 | 2 | 2 |
4 | 7 | 1979.04 | 20 | 10.66 | 3192 | 681 | 4.77 / 1482.30 | 2 | 2 |
5 | 13 | 125.20 | 5 | 13.84 | 579 | 40 | 4.81 / 1482.34 | 2 | 9 |
6 | 13 | 82.80 | 5 | 13.88 | 513 | 36 | 4.85 / 1482.38 | 2 | 8 |
7 | 13 | 44.28 | 5 | 13.97 | 467 | 33 | 4.88 / 1482.41 | 2 | 7 |
8 | 13 | 41.08 | 5 | 14.00 | 464 | 32 | 4.92 / 1482.44 | 2 | 8 |
9 | 8 | 0.24 | 190 | 13.70 | 376 | 979 | 5.89 / 1483.42 | 2 | 20 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 29 | 13.97 | 517 | 209 | 0.21 / 1473.83 | 2 | 6 |
2 | 12 | 1124.24 | 114 | 9.73 | 1948 | 2161 | 2.37 / 1475.99 | 2 | 2 |
3 | 7 | 1114.20 | 21 | 11.01 | 1950 | 451 | 2.82 / 1476.45 | 2 | 3 |
4 | 13 | 78.64 | 5 | 13.92 | 515 | 36 | 2.86 / 1476.48 | 2 | 8 |
5 | 13 | 48.16 | 5 | 13.99 | 470 | 33 | 2.89 / 1476.51 | 2 | 8 |
6 | 13 | 43.80 | 5 | 13.97 | 462 | 32 | 2.92 / 1476.55 | 2 | 8 |
7 | 8 | -0.20 | 190 | 13.73 | 376 | 981 | 3.90 / 1477.53 | 2 | 26 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 29 | 14.01 | 514 | 209 | 0.21 / 1469.91 | 2 | 7 |
2 | 12 | 1082.88 | 114 | 10.16 | 1898 | 2198 | 2.41 / 1472.11 | 2 | 3 |
3 | 7 | 1069.48 | 21 | 11.15 | 1892 | 443 | 2.85 / 1472.56 | 3 | 4 |
4 | 13 | 66.56 | 5 | 14.00 | 489 | 34 | 2.88 / 1472.59 | 2 | 8 |
5 | 13 | 55.44 | 5 | 14.00 | 471 | 33 | 2.92 / 1472.62 | 2 | 8 |
6 | 13 | 47.36 | 5 | 14.03 | 459 | 32 | 2.95 / 1472.66 | 2 | 8 |
7 | 8 | -0.04 | 190 | 13.78 | 370 | 969 | 3.92 / 1473.62 | 2 | 14 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 28 | 14.02 | 512 | 201 | 0.20 / 1465.90 | 2 | 6 |
2 | 3 | 1020.76 | 1 | 12.48 | 1904 | 24 | 0.22 / 1465.93 | 2 | 2 |
3 | 12 | 1103.20 | 114 | 10.39 | 1934 | 2291 | 2.52 / 1468.22 | 2 | 3 |
4 | 7 | 1089.80 | 21 | 11.32 | 1933 | 460 | 2.98 / 1468.68 | 3 | 4 |
5 | 13 | 72.80 | 5 | 13.99 | 505 | 35 | 3.01 / 1468.71 | 2 | 9 |
6 | 8 | 0.64 | 190 | 13.74 | 381 | 995 | 4.00 / 1469.71 | 2 | 14 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 28 | 13.99 | 518 | 203 | 0.20 / 1459.76 | 2 | 6 |
2 | 3 | 1033.72 | 1 | 12.55 | 1912 | 24 | 0.23 / 1459.78 | 2 | 2 |
3 | 12 | 1119.76 | 5 | 12.34 | 2004 | 124 | 0.35 / 1459.91 | 2 | 3 |
4 | 12 | 1989.80 | 114 | 10.52 | 3194 | 3831 | 4.18 / 1463.74 | 2 | 2 |
5 | 7 | 1964.04 | 21 | 10.81 | 3161 | 718 | 4.90 / 1464.46 | 2 | 2 |
6 | 13 | 72.68 | 5 | 13.99 | 504 | 35 | 4.93 / 1464.49 | 2 | 9 |
7 | 13 | 55.52 | 5 | 14.03 | 479 | 34 | 4.97 / 1464.52 | 2 | 8 |
8 | 13 | 1.52 | 36 | 14.09 | 393 | 199 | 5.17 / 1464.72 | 2 | 8 |
9 | 8 | -0.16 | 190 | 13.71 | 375 | 977 | 6.14 / 1465.70 | 2 | 15 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 29 | 14.04 | 499 | 203 | 0.20 / 1455.90 | 2 | 4 |
2 | 12 | 1126.76 | 114 | 9.83 | 1955 | 2191 | 2.39 / 1458.09 | 2 | 2 |
3 | 7 | 1118.20 | 21 | 11.04 | 1957 | 454 | 2.85 / 1458.55 | 2 | 3 |
4 | 13 | 43.76 | 5 | 14.07 | 458 | 32 | 2.88 / 1458.58 | 2 | 8 |
5 | 8 | 0.60 | 190 | 13.78 | 374 | 979 | 3.86 / 1459.56 | 2 | 14 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 28 | 14.04 | 520 | 204 | 0.20 / 1451.96 | 2 | 7 |
2 | 12 | 1104.40 | 114 | 10.14 | 1933 | 2234 | 2.44 / 1454.20 | 2 | 3 |
3 | 7 | 1092.64 | 21 | 11.16 | 1929 | 452 | 2.89 / 1454.65 | 3 | 4 |
4 | 13 | 46.00 | 5 | 14.06 | 467 | 33 | 2.92 / 1454.68 | 2 | 9 |
5 | 13 | 42.88 | 5 | 14.03 | 461 | 32 | 2.96 / 1454.71 | 2 | 9 |
6 | 8 | 0.24 | 190 | 13.81 | 375 | 984 | 3.94 / 1455.70 | 2 | 19 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 28 | 14.01 | 516 | 202 | 0.20 / 1448.02 | 2 | 7 |
2 | 12 | 1118.80 | 114 | 10.35 | 1953 | 2304 | 2.51 / 1450.33 | 2 | 3 |
3 | 7 | 1106.52 | 20 | 11.40 | 1947 | 444 | 2.95 / 1450.77 | 3 | 4 |
4 | 8 | 0.20 | 190 | 13.80 | 377 | 988 | 3.94 / 1451.76 | 2 | 21 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 28 | 14.03 | 514 | 202 | 0.20 / 1442.08 | 2 | 6 |
2 | 12 | 1089.88 | 5 | 12.64 | 1951 | 123 | 0.33 / 1442.20 | 2 | 3 |
3 | 12 | 1984.16 | 114 | 10.58 | 3180 | 3835 | 4.16 / 1446.04 | 2 | 2 |
4 | 7 | 1959.68 | 20 | 10.87 | 3166 | 688 | 4.85 / 1446.73 | 2 | 2 |
5 | 13 | 112.16 | 5 | 14.02 | 560 | 39 | 4.89 / 1446.77 | 2 | 9 |
6 | 13 | 77.12 | 5 | 14.01 | 509 | 36 | 4.92 / 1446.80 | 2 | 9 |
7 | 13 | 56.88 | 5 | 14.09 | 480 | 34 | 4.96 / 1446.84 | 2 | 9 |
8 | 8 | 0.16 | 190 | 13.81 | 374 | 981 | 5.94 / 1447.82 | 2 | 14 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 29 | 14.02 | 509 | 207 | 0.21 / 1438.00 | 2 | 5 |
2 | 12 | 1115.20 | 114 | 9.84 | 1939 | 2175 | 2.38 / 1440.17 | 2 | 2 |
3 | 7 | 1103.28 | 21 | 11.03 | 1951 | 452 | 2.83 / 1440.63 | 2 | 4 |
4 | 13 | 76.92 | 5 | 14.06 | 516 | 36 | 2.87 / 1440.66 | 2 | 8 |
5 | 13 | 47.76 | 5 | 14.07 | 479 | 34 | 2.90 / 1440.70 | 2 | 9 |
6 | 13 | 4.56 | 36 | 14.09 | 399 | 202 | 3.11 / 1440.90 | 2 | 14 |
7 | 8 | 0.24 | 190 | 13.76 | 375 | 980 | 4.09 / 1441.88 | 2 | 20 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 28 | 14.06 | 514 | 202 | 0.20 / 1433.88 | 2 | 5 |
2 | 12 | 1128.48 | 114 | 10.07 | 1964 | 2255 | 2.46 / 1436.13 | 2 | 3 |
3 | 7 | 1118.04 | 21 | 11.11 | 1972 | 460 | 2.92 / 1436.59 | 3 | 4 |
4 | 13 | 15.52 | 36 | 14.09 | 410 | 208 | 3.13 / 1436.80 | 2 | 10 |
5 | 8 | 0.20 | 190 | 13.75 | 379 | 990 | 4.12 / 1437.79 | 2 | 17 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 29 | 14.00 | 522 | 212 | 0.21 / 1429.65 | 2 | 5 |
2 | 3 | 958.00 | -1 | 14.00 | 522 | 0 | 0.00 / 1429.65 | 2 | 5 |
3 | 12 | 1116.76 | 114 | 10.33 | 1951 | 2298 | 2.51 / 1431.95 | 2 | 3 |
4 | 7 | 1103.92 | 21 | 11.38 | 1943 | 464 | 2.97 / 1432.41 | 3 | 5 |
5 | 13 | 45.52 | 5 | 14.12 | 471 | 33 | 3.01 / 1432.45 | 2 | 9 |
6 | 13 | 42.80 | 5 | 14.08 | 463 | 33 | 3.04 / 1432.48 | 2 | 9 |
7 | 13 | 17.72 | 36 | 14.12 | 413 | 210 | 3.25 / 1432.69 | 2 | 10 |
8 | 8 | -0.04 | 190 | 13.86 | 376 | 990 | 4.24 / 1433.68 | 2 | 16 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 29 | 14.03 | 520 | 212 | 0.21 / 1423.52 | 2 | 5 |
2 | 3 | 968.20 | -1 | 14.03 | 520 | 0 | 0.00 / 1423.52 | 2 | 5 |
3 | 12 | 1130.88 | 5 | 12.49 | 2029 | 127 | 0.34 / 1423.65 | 2 | 3 |
4 | 12 | 1983.24 | 114 | 10.58 | 3188 | 3845 | 4.18 / 1427.49 | 2 | 2 |
5 | 7 | 1957.52 | 21 | 10.85 | 3174 | 723 | 4.91 / 1428.21 | 2 | 2 |
6 | 13 | 107.48 | 5 | 14.07 | 560 | 39 | 4.95 / 1428.25 | 2 | 9 |
7 | 13 | 1.96 | 36 | 14.08 | 402 | 204 | 5.15 / 1428.46 | 2 | 8 |
8 | 8 | 0.24 | 190 | 13.77 | 375 | 981 | 6.13 / 1429.44 | 2 | 15 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 28 | 14.05 | 501 | 197 | 0.20 / 1419.40 | 2 | 4 |
2 | 12 | 1129.96 | 114 | 9.80 | 1961 | 2191 | 2.39 / 1421.59 | 2 | 3 |
3 | 7 | 1119.96 | 20 | 11.05 | 1973 | 436 | 2.82 / 1422.02 | 3 | 4 |
4 | 13 | 86.40 | 5 | 14.09 | 524 | 37 | 2.86 / 1422.06 | 2 | 9 |
5 | 13 | 23.08 | 5 | 14.07 | 441 | 31 | 2.89 / 1422.09 | 2 | 9 |
6 | 13 | 21.92 | 5 | 14.06 | 433 | 30 | 2.92 / 1422.12 | 2 | 9 |
7 | 13 | 16.88 | 36 | 14.06 | 406 | 206 | 3.13 / 1422.33 | 2 | 11 |
8 | 8 | -0.08 | 190 | 13.74 | 375 | 979 | 4.11 / 1423.31 | 2 | 21 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 28 | 14.06 | 515 | 203 | 0.20 / 1415.26 | 2 | 5 |
2 | 3 | 1032.00 | 1 | 12.94 | 1906 | 25 | 0.23 / 1415.28 | 2 | 2 |
3 | 12 | 1137.60 | 114 | 10.03 | 1970 | 2253 | 2.48 / 1417.54 | 2 | 3 |
4 | 7 | 1127.28 | 20 | 11.17 | 1979 | 442 | 2.92 / 1417.98 | 3 | 4 |
5 | 13 | 73.48 | 5 | 14.08 | 500 | 35 | 2.96 / 1418.01 | 2 | 8 |
6 | 13 | 55.40 | 5 | 14.08 | 477 | 34 | 2.99 / 1418.05 | 2 | 9 |
7 | 13 | 1.56 | 36 | 14.12 | 389 | 198 | 3.19 / 1418.24 | 2 | 11 |
8 | 8 | -0.04 | 190 | 13.71 | 367 | 956 | 4.14 / 1419.20 | 2 | 15 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 28 | 14.03 | 501 | 197 | 0.20 / 1411.29 | 2 | 4 |
2 | 3 | 962.88 | -1 | 14.03 | 501 | 0 | 0.00 / 1411.29 | 2 | 4 |
3 | 3 | 1039.12 | 1 | 13.04 | 1919 | 25 | 0.22 / 1411.32 | 2 | 2 |
4 | 12 | 1117.04 | 114 | 10.28 | 1948 | 2283 | 2.50 / 1413.60 | 2 | 3 |
5 | 7 | 1104.92 | 21 | 11.38 | 1942 | 464 | 2.97 / 1414.06 | 3 | 4 |
6 | 8 | 0.08 | 190 | 13.85 | 377 | 992 | 3.96 / 1415.06 | 2 | 15 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 31 | 14.02 | 508 | 221 | 0.22 / 1405.10 | 2 | 4 |
2 | 3 | 946.36 | -1 | 14.02 | 508 | 0 | 0.00 / 1405.10 | 2 | 4 |
3 | 12 | 1127.92 | 5 | 12.42 | 2017 | 125 | 0.35 / 1405.23 | 2 | 2 |
4 | 12 | 1992.20 | 114 | 10.55 | 3196 | 3844 | 4.19 / 1409.07 | 2 | 2 |
5 | 7 | 1967.32 | 20 | 10.87 | 3185 | 692 | 4.88 / 1409.76 | 2 | 2 |
6 | 13 | 108.00 | 5 | 14.06 | 566 | 40 | 4.92 / 1409.80 | 2 | 9 |
7 | 13 | 76.44 | 5 | 14.06 | 512 | 36 | 4.96 / 1409.84 | 2 | 9 |
8 | 13 | 57.28 | 5 | 14.07 | 486 | 34 | 4.99 / 1409.87 | 2 | 9 |
9 | 13 | 43.40 | 5 | 14.08 | 468 | 33 | 5.03 / 1409.91 | 2 | 9 |
10 | 13 | 14.20 | 36 | 14.09 | 410 | 208 | 5.23 / 1410.11 | 2 | 10 |
11 | 8 | -0.04 | 190 | 13.80 | 374 | 981 | 6.21 / 1411.09 | 2 | 17 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 28 | 14.01 | 512 | 201 | 0.20 / 1401.20 | 2 | 4 |
2 | 12 | 1111.88 | 114 | 9.84 | 1936 | 2172 | 2.37 / 1403.37 | 2 | 2 |
3 | 7 | 1099.80 | 21 | 11.06 | 1936 | 450 | 2.82 / 1403.82 | 2 | 4 |
4 | 13 | 56.16 | 5 | 14.08 | 484 | 34 | 2.86 / 1403.85 | 2 | 9 |
5 | 13 | 40.12 | 5 | 14.05 | 460 | 32 | 2.89 / 1403.89 | 2 | 9 |
6 | 8 | 0.56 | 190 | 13.83 | 379 | 996 | 3.88 / 1404.88 | 2 | 15 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 28 | 14.02 | 519 | 204 | 0.20 / 1397.06 | 2 | 5 |
2 | 3 | 1018.76 | 1 | 12.84 | 1909 | 25 | 0.23 / 1397.08 | 2 | 2 |
3 | 12 | 1120.04 | 114 | 10.10 | 1952 | 2248 | 2.48 / 1399.33 | 2 | 3 |
4 | 7 | 1107.56 | 20 | 11.20 | 1958 | 439 | 2.91 / 1399.77 | 3 | 4 |
5 | 13 | 108.56 | 5 | 14.04 | 565 | 40 | 2.95 / 1399.81 | 2 | 9 |
6 | 13 | 16.04 | 36 | 14.07 | 405 | 205 | 3.16 / 1400.01 | 2 | 9 |
7 | 8 | 0.00 | 190 | 13.80 | 375 | 983 | 4.14 / 1401.00 | 2 | 16 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 28 | 14.01 | 493 | 193 | 0.19 / 1392.75 | 2 | 4 |
2 | 10 | 1005.00 | 3 | 13.36 | 1845 | 74 | 0.27 / 1392.82 | 2 | 6 |
3 | 3 | 941.12 | -1 | 13.36 | 1845 | 0 | 0.07 / 1392.82 | 2 | 6 |
4 | 3 | 960.36 | -1 | 13.36 | 1845 | 0 | 0.07 / 1392.82 | 2 | 6 |
5 | 12 | 1155.88 | 114 | 10.26 | 2005 | 2345 | 2.61 / 1395.17 | 2 | 3 |
6 | 7 | 1144.56 | 21 | 11.35 | 2006 | 478 | 3.09 / 1395.65 | 3 | 4 |
7 | 13 | 73.48 | 5 | 14.13 | 502 | 35 | 3.13 / 1395.68 | 2 | 9 |
8 | 13 | 13.00 | 36 | 14.08 | 401 | 203 | 3.33 / 1395.88 | 2 | 8 |
9 | 8 | -0.08 | 190 | 13.83 | 369 | 970 | 4.30 / 1396.85 | 2 | 15 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 27 | 14.01 | 506 | 191 | 0.19 / 1386.52 | 2 | 3 |
2 | 10 | 1043.92 | 5 | 13.21 | 1879 | 124 | 0.32 / 1386.65 | 2 | 5 |
3 | 3 | 885.24 | -2 | 13.21 | 1879 | 0 | 0.12 / 1386.65 | 2 | 5 |
4 | 3 | 1043.04 | 1 | 12.74 | 1909 | 24 | 0.34 / 1386.67 | 2 | 2 |
5 | 12 | 1055.84 | 5 | 12.14 | 1918 | 116 | 0.46 / 1386.79 | 2 | 2 |
6 | 12 | 1983.40 | 114 | 10.47 | 3175 | 3790 | 4.25 / 1390.58 | 2 | 2 |
7 | 7 | 1963.56 | 21 | 10.87 | 3173 | 724 | 4.97 / 1391.30 | 2 | 2 |
8 | 13 | 246.56 | 5 | 13.99 | 745 | 52 | 5.02 / 1391.35 | 2 | 10 |
9 | 13 | 47.16 | 5 | 14.13 | 468 | 33 | 5.06 / 1391.39 | 2 | 9 |
10 | 13 | 3.24 | 36 | 14.08 | 393 | 199 | 5.25 / 1391.58 | 2 | 8 |
11 | 8 | -0.08 | 190 | 13.84 | 369 | 970 | 6.22 / 1392.56 | 2 | 15 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 28 | 14.02 | 504 | 198 | 0.20 / 1383.88 | 2 | 4 |
2 | 3 | 969.44 | -1 | 14.02 | 504 | 0 | 0.00 / 1383.88 | 2 | 4 |
3 | 3 | 1047.32 | 1 | 12.87 | 1923 | 25 | 0.22 / 1383.90 | 2 | 3 |
4 | 7 | 1132.96 | 20 | 11.12 | 2003 | 445 | 0.67 / 1384.35 | 3 | 3 |
5 | 13 | 1022.04 | 36 | 12.92 | 1815 | 844 | 1.51 / 1385.19 | 2 | 6 |
6 | 13 | 183.20 | 5 | 14.01 | 652 | 46 | 1.56 / 1385.24 | 2 | 9 |
7 | 13 | 174.48 | 5 | 14.04 | 637 | 45 | 1.60 / 1385.28 | 2 | 9 |
8 | 13 | 78.68 | 5 | 14.07 | 511 | 36 | 1.64 / 1385.32 | 2 | 9 |
9 | 13 | 60.92 | 5 | 14.09 | 485 | 34 | 1.67 / 1385.35 | 2 | 9 |
10 | 8 | 0.36 | 190 | 13.87 | 371 | 978 | 2.65 / 1386.33 | 2 | 14 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 27 | 14.01 | 502 | 190 | 0.19 / 1379.86 | 2 | 4 |
2 | 3 | 1041.12 | 1 | 13.08 | 1903 | 25 | 0.21 / 1379.88 | 2 | 2 |
3 | 12 | 1110.80 | 114 | 9.97 | 1931 | 2195 | 2.41 / 1382.08 | 2 | 2 |
4 | 7 | 1097.24 | 21 | 11.15 | 1933 | 453 | 2.86 / 1382.53 | 2 | 3 |
5 | 13 | 22.08 | 36 | 14.08 | 394 | 200 | 3.06 / 1382.73 | 2 | 7 |
6 | 8 | -0.12 | 190 | 13.91 | 360 | 951 | 4.01 / 1383.68 | 2 | 16 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 28 | 13.99 | 498 | 195 | 0.20 / 1375.71 | 2 | 3 |
2 | 3 | 971.40 | -1 | 13.99 | 498 | 0 | 0.00 / 1375.71 | 2 | 3 |
3 | 12 | 1098.32 | 114 | 10.14 | 1912 | 2210 | 2.41 / 1377.92 | 2 | 3 |
4 | 7 | 1082.52 | 21 | 11.34 | 1913 | 456 | 2.86 / 1378.37 | 3 | 4 |
5 | 13 | 225.56 | 36 | 13.89 | 660 | 330 | 3.19 / 1378.70 | 2 | 9 |
6 | 8 | -0.04 | 190 | 13.88 | 366 | 965 | 4.16 / 1379.67 | 2 | 15 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 27 | 14.03 | 491 | 186 | 0.19 / 1369.65 | 2 | 3 |
2 | 12 | 1077.40 | 5 | 12.47 | 1924 | 120 | 0.31 / 1369.77 | 2 | 2 |
3 | 12 | 1986.20 | 114 | 10.49 | 3177 | 3799 | 4.11 / 1373.57 | 2 | 2 |
4 | 7 | 1962.84 | 21 | 10.83 | 3168 | 720 | 4.83 / 1374.29 | 2 | 2 |
5 | 13 | 106.68 | 36 | 13.98 | 518 | 261 | 5.09 / 1374.55 | 2 | 8 |
6 | 8 | 0.04 | 190 | 13.88 | 365 | 963 | 6.05 / 1375.51 | 2 | 17 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 28 | 14.02 | 491 | 193 | 0.19 / 1365.69 | 2 | 4 |
2 | 12 | 1106.44 | 114 | 9.84 | 1916 | 2149 | 2.34 / 1367.84 | 2 | 2 |
3 | 7 | 1093.92 | 21 | 11.10 | 1923 | 448 | 2.79 / 1368.28 | 2 | 3 |
4 | 13 | 51.12 | 36 | 14.03 | 440 | 222 | 3.01 / 1368.51 | 2 | 6 |
5 | 8 | -0.08 | 190 | 13.89 | 362 | 955 | 3.97 / 1369.46 | 2 | 12 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 28 | 14.01 | 500 | 196 | 0.20 / 1361.76 | 2 | 4 |
2 | 12 | 1126.72 | 114 | 9.99 | 1951 | 2222 | 2.42 / 1363.98 | 2 | 2 |
3 | 7 | 1114.16 | 21 | 11.16 | 1946 | 456 | 2.87 / 1364.43 | 2 | 3 |
4 | 13 | 58.12 | 5 | 14.11 | 483 | 34 | 2.91 / 1364.47 | 2 | 7 |
5 | 13 | 48.32 | 5 | 14.08 | 465 | 33 | 2.94 / 1364.50 | 2 | 7 |
6 | 13 | 44.08 | 5 | 14.06 | 459 | 32 | 2.97 / 1364.53 | 2 | 8 |
7 | 8 | 0.12 | 190 | 13.90 | 364 | 961 | 3.93 / 1365.49 | 2 | 14 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 29 | 14.01 | 492 | 200 | 0.20 / 1357.83 | 2 | 3 |
2 | 3 | 970.36 | -1 | 14.01 | 492 | 0 | 0.00 / 1357.83 | 2 | 3 |
3 | 12 | 1140.92 | 114 | 10.04 | 1968 | 2252 | 2.45 / 1360.08 | 2 | 2 |
4 | 7 | 1128.96 | 21 | 11.31 | 1973 | 469 | 2.92 / 1360.55 | 2 | 3 |
5 | 13 | 46.28 | 5 | 14.14 | 452 | 32 | 2.95 / 1360.58 | 2 | 8 |
6 | 8 | 0.04 | 190 | 13.90 | 369 | 975 | 3.93 / 1361.56 | 2 | 10 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 29 | 13.96 | 493 | 200 | 0.20 / 1351.87 | 2 | 3 |
2 | 3 | 938.60 | -1 | 13.96 | 493 | 0 | 0.00 / 1351.87 | 2 | 3 |
3 | 12 | 1086.24 | 5 | 12.42 | 1929 | 120 | 0.32 / 1351.99 | 2 | 2 |
4 | 12 | 1986.56 | 114 | 10.46 | 3190 | 3804 | 4.12 / 1355.79 | 2 | 2 |
5 | 7 | 1962.36 | 21 | 10.85 | 3164 | 721 | 4.84 / 1356.51 | 2 | 2 |
6 | 13 | 129.12 | 5 | 14.10 | 583 | 41 | 4.89 / 1356.55 | 2 | 8 |
7 | 13 | 80.72 | 5 | 14.10 | 514 | 36 | 4.92 / 1356.59 | 2 | 8 |
8 | 13 | 59.92 | 5 | 14.10 | 482 | 34 | 4.96 / 1356.62 | 2 | 8 |
9 | 13 | 50.28 | 5 | 14.10 | 472 | 33 | 4.99 / 1356.66 | 2 | 8 |
10 | 8 | 0.16 | 190 | 13.89 | 369 | 974 | 5.96 / 1357.63 | 2 | 13 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 29 | 13.95 | 503 | 203 | 0.20 / 1347.80 | 2 | 3 |
2 | 3 | 968.12 | -1 | 13.95 | 503 | 0 | 0.00 / 1347.80 | 2 | 3 |
3 | 3 | 1018.96 | 1 | 12.51 | 1876 | 23 | 0.23 / 1347.82 | 2 | 2 |
4 | 12 | 1132.36 | 114 | 9.79 | 1953 | 2180 | 2.41 / 1350.00 | 2 | 2 |
5 | 7 | 1123.00 | 21 | 11.11 | 1959 | 457 | 2.86 / 1350.46 | 2 | 3 |
6 | 13 | 83.88 | 5 | 14.09 | 521 | 37 | 2.90 / 1350.50 | 2 | 8 |
7 | 13 | 15.32 | 36 | 14.06 | 398 | 201 | 3.10 / 1350.70 | 2 | 6 |
8 | 8 | 0.24 | 190 | 13.84 | 369 | 970 | 4.07 / 1351.67 | 2 | 12 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 29 | 13.96 | 494 | 200 | 0.20 / 1343.63 | 2 | 3 |
2 | 12 | 1136.76 | 114 | 10.05 | 1966 | 2252 | 2.45 / 1345.89 | 2 | 2 |
3 | 7 | 1125.00 | 21 | 11.19 | 1976 | 464 | 2.92 / 1346.35 | 2 | 3 |
4 | 13 | 72.76 | 5 | 14.10 | 501 | 35 | 2.95 / 1346.39 | 2 | 8 |
5 | 13 | 56.24 | 5 | 14.09 | 470 | 33 | 2.99 / 1346.42 | 2 | 8 |
6 | 13 | 43.64 | 5 | 14.09 | 453 | 32 | 3.02 / 1346.45 | 2 | 8 |
7 | 13 | 16.28 | 36 | 14.06 | 390 | 197 | 3.21 / 1346.65 | 2 | 6 |
8 | 8 | 0.00 | 190 | 13.85 | 360 | 947 | 4.16 / 1347.60 | 2 | 15 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 28 | 13.94 | 494 | 193 | 0.19 / 1339.63 | 2 | 3 |
2 | 3 | 1019.56 | 1 | 12.77 | 1903 | 24 | 0.22 / 1339.65 | 2 | 2 |
3 | 12 | 1165.96 | 114 | 9.99 | 2009 | 2288 | 2.51 / 1341.94 | 2 | 2 |
4 | 7 | 1155.12 | 21 | 11.28 | 2014 | 477 | 2.98 / 1342.42 | 2 | 4 |
5 | 13 | 57.92 | 5 | 14.13 | 473 | 33 | 3.02 / 1342.45 | 2 | 8 |
6 | 8 | 0.28 | 190 | 13.88 | 373 | 984 | 4.00 / 1343.43 | 2 | 11 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 28 | 13.92 | 505 | 197 | 0.20 / 1333.67 | 2 | 3 |
2 | 12 | 1111.76 | 5 | 12.15 | 1988 | 121 | 0.32 / 1333.79 | 2 | 2 |
3 | 12 | 1990.84 | 114 | 10.40 | 3195 | 3788 | 4.11 / 1337.58 | 2 | 2 |
4 | 7 | 1966.00 | 21 | 10.80 | 3175 | 720 | 4.83 / 1338.30 | 2 | 2 |
5 | 13 | 113.88 | 5 | 14.07 | 567 | 40 | 4.87 / 1338.34 | 2 | 9 |
6 | 13 | 78.16 | 5 | 14.07 | 515 | 36 | 4.90 / 1338.38 | 2 | 8 |
7 | 13 | 59.12 | 5 | 14.08 | 490 | 34 | 4.94 / 1338.41 | 2 | 9 |
8 | 13 | 48.80 | 5 | 14.08 | 475 | 33 | 4.97 / 1338.45 | 2 | 9 |
9 | 8 | 0.32 | 190 | 13.85 | 376 | 989 | 5.96 / 1339.44 | 2 | 17 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 29 | 13.93 | 509 | 206 | 0.21 / 1329.76 | 2 | 4 |
2 | 12 | 1055.12 | 5 | 10.63 | 1886 | 100 | 0.31 / 1329.86 | 2 | 2 |
3 | 12 | 1065.48 | 114 | 10.33 | 1860 | 2190 | 2.50 / 1332.06 | 2 | 3 |
4 | 7 | 1038.00 | 21 | 11.14 | 1858 | 435 | 2.93 / 1332.49 | 3 | 5 |
5 | 8 | 0.08 | 190 | 13.85 | 375 | 987 | 3.92 / 1333.48 | 2 | 16 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 28 | 13.93 | 498 | 194 | 0.19 / 1325.60 | 2 | 4 |
2 | 12 | 1147.24 | 114 | 10.00 | 1982 | 2259 | 2.45 / 1327.86 | 2 | 2 |
3 | 7 | 1135.12 | 21 | 11.16 | 1986 | 465 | 2.92 / 1328.33 | 2 | 3 |
4 | 13 | 80.44 | 5 | 14.07 | 509 | 36 | 2.95 / 1328.36 | 2 | 8 |
5 | 13 | 58.72 | 5 | 14.07 | 478 | 34 | 2.99 / 1328.40 | 2 | 8 |
6 | 13 | 13.36 | 36 | 14.04 | 398 | 201 | 3.19 / 1328.60 | 2 | 11 |
7 | 8 | -0.12 | 190 | 13.81 | 366 | 960 | 4.15 / 1329.56 | 2 | 18 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 28 | 13.92 | 528 | 206 | 0.21 / 1321.43 | 2 | 5 |
2 | 12 | 1153.68 | 114 | 10.02 | 1994 | 2278 | 2.48 / 1323.71 | 2 | 2 |
3 | 7 | 1141.88 | 21 | 11.28 | 1992 | 472 | 2.96 / 1324.18 | 2 | 4 |
4 | 13 | 45.88 | 5 | 14.11 | 463 | 33 | 2.99 / 1324.21 | 2 | 8 |
5 | 13 | 42.68 | 5 | 14.07 | 454 | 32 | 3.02 / 1324.25 | 2 | 8 |
6 | 13 | 3.36 | 36 | 14.06 | 387 | 196 | 3.22 / 1324.44 | 2 | 10 |
7 | 8 | -0.04 | 190 | 13.82 | 368 | 966 | 4.18 / 1325.41 | 2 | 16 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 28 | 13.89 | 500 | 194 | 0.19 / 1315.36 | 2 | 4 |
2 | 12 | 1099.80 | 5 | 12.19 | 1977 | 120 | 0.31 / 1315.48 | 2 | 2 |
3 | 12 | 1991.64 | 114 | 10.39 | 3194 | 3783 | 4.10 / 1319.26 | 2 | 2 |
4 | 7 | 1967.40 | 20 | 10.83 | 3168 | 686 | 4.78 / 1319.95 | 2 | 2 |
5 | 13 | 116.32 | 5 | 14.06 | 573 | 40 | 4.82 / 1319.99 | 2 | 9 |
6 | 13 | 78.72 | 5 | 14.07 | 522 | 37 | 4.86 / 1320.03 | 2 | 8 |
7 | 13 | 16.72 | 36 | 14.03 | 416 | 210 | 5.07 / 1320.24 | 2 | 9 |
8 | 8 | 0.00 | 190 | 13.83 | 377 | 991 | 6.06 / 1321.23 | 2 | 14 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 27 | 13.91 | 529 | 199 | 0.20 / 1311.37 | 2 | 4 |
2 | 3 | 1068.24 | 2 | 13.00 | 1946 | 51 | 0.25 / 1311.42 | 2 | 3 |
3 | 12 | 1066.48 | 5 | 10.57 | 1903 | 101 | 0.35 / 1311.52 | 2 | 2 |
4 | 12 | 1089.92 | 114 | 10.22 | 1895 | 2208 | 2.56 / 1313.73 | 2 | 3 |
5 | 7 | 1064.20 | 21 | 11.16 | 1888 | 442 | 3.00 / 1314.17 | 3 | 5 |
6 | 8 | 0.08 | 190 | 13.85 | 377 | 992 | 3.99 / 1315.16 | 2 | 13 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 28 | 13.88 | 528 | 205 | 0.21 / 1307.43 | 2 | 5 |
2 | 12 | 1054.56 | 5 | 10.86 | 1888 | 103 | 0.31 / 1307.53 | 2 | 2 |
3 | 12 | 1056.04 | 114 | 10.51 | 1848 | 2214 | 2.52 / 1309.75 | 2 | 3 |
4 | 7 | 1025.96 | 21 | 11.19 | 1832 | 431 | 2.95 / 1310.18 | 3 | 5 |
5 | 8 | 0.04 | 190 | 13.84 | 379 | 997 | 3.95 / 1311.17 | 2 | 15 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 27 | 13.90 | 517 | 194 | 0.19 / 1303.46 | 2 | 5 |
2 | 3 | 1029.72 | 1 | 12.95 | 1901 | 25 | 0.22 / 1303.49 | 2 | 2 |
3 | 3 | 1021.12 | 1 | 12.49 | 1892 | 24 | 0.24 / 1303.51 | 2 | 2 |
4 | 12 | 1121.60 | 114 | 9.96 | 1947 | 2211 | 2.45 / 1305.72 | 2 | 2 |
5 | 7 | 1109.56 | 21 | 11.25 | 1960 | 463 | 2.92 / 1306.18 | 2 | 4 |
6 | 13 | 56.20 | 5 | 14.08 | 484 | 34 | 2.95 / 1306.22 | 2 | 8 |
7 | 8 | 0.40 | 190 | 13.84 | 382 | 1005 | 3.95 / 1307.22 | 2 | 14 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 28 | 13.89 | 514 | 200 | 0.20 / 1297.41 | 2 | 5 |
2 | 12 | 1107.36 | 5 | 12.30 | 1982 | 122 | 0.32 / 1297.53 | 2 | 2 |
3 | 12 | 1991.24 | 114 | 10.41 | 3189 | 3785 | 4.11 / 1301.31 | 2 | 2 |
4 | 7 | 1966.72 | 20 | 10.81 | 3177 | 687 | 4.79 / 1302.00 | 2 | 2 |
5 | 13 | 130.96 | 5 | 14.05 | 580 | 41 | 4.83 / 1302.04 | 2 | 9 |
6 | 13 | 83.64 | 5 | 14.09 | 508 | 36 | 4.87 / 1302.08 | 2 | 8 |
7 | 13 | 49.44 | 5 | 14.09 | 468 | 33 | 4.90 / 1302.11 | 2 | 7 |
8 | 13 | 14.12 | 36 | 14.04 | 398 | 201 | 5.10 / 1302.31 | 2 | 7 |
9 | 8 | 0.12 | 190 | 13.82 | 365 | 958 | 6.06 / 1303.27 | 2 | 16 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 28 | 13.87 | 524 | 204 | 0.20 / 1293.39 | 2 | 7 |
2 | 3 | 970.80 | -1 | 13.87 | 524 | 0 | 0.00 / 1293.39 | 2 | 7 |
3 | 12 | 1112.76 | 114 | 9.86 | 1935 | 2175 | 2.38 / 1295.56 | 2 | 2 |
4 | 7 | 1101.60 | 21 | 11.12 | 1954 | 456 | 2.83 / 1296.02 | 2 | 3 |
5 | 13 | 16.32 | 36 | 14.01 | 409 | 206 | 3.04 / 1296.23 | 2 | 8 |
6 | 8 | -0.24 | 190 | 13.77 | 375 | 981 | 4.02 / 1297.21 | 2 | 15 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 27 | 13.88 | 522 | 196 | 0.20 / 1289.13 | 2 | 6 |
2 | 10 | 1012.84 | 3 | 13.35 | 1879 | 75 | 0.27 / 1289.20 | 2 | 5 |
3 | 3 | 921.40 | -1 | 13.35 | 1879 | 0 | 0.08 / 1289.20 | 2 | 5 |
4 | 3 | 963.28 | -1 | 13.35 | 1879 | 0 | 0.08 / 1289.20 | 2 | 5 |
5 | 12 | 1136.08 | 114 | 9.94 | 1966 | 2228 | 2.50 / 1291.43 | 2 | 2 |
6 | 7 | 1124.12 | 21 | 11.16 | 1979 | 464 | 2.96 / 1291.89 | 2 | 3 |
7 | 13 | 34.44 | 5 | 14.07 | 457 | 32 | 2.99 / 1291.93 | 2 | 8 |
8 | 13 | 33.52 | 5 | 14.03 | 454 | 32 | 3.03 / 1291.96 | 2 | 8 |
9 | 13 | 30.48 | 5 | 14.02 | 453 | 32 | 3.06 / 1291.99 | 2 | 10 |
10 | 13 | 14.64 | 36 | 14.00 | 413 | 208 | 3.27 / 1292.20 | 2 | 7 |
11 | 8 | -0.16 | 190 | 13.76 | 377 | 986 | 4.25 / 1293.18 | 2 | 17 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 28 | 13.89 | 519 | 202 | 0.20 / 1284.78 | 2 | 7 |
2 | 3 | 935.56 | -1 | 13.89 | 519 | 0 | 0.00 / 1284.78 | 2 | 7 |
3 | 12 | 1142.36 | 114 | 9.94 | 1975 | 2238 | 2.44 / 1287.01 | 2 | 2 |
4 | 7 | 1129.40 | 21 | 11.26 | 1988 | 470 | 2.91 / 1287.48 | 2 | 3 |
5 | 13 | 59.24 | 5 | 14.07 | 486 | 34 | 2.94 / 1287.52 | 2 | 8 |
6 | 13 | 49.92 | 5 | 14.06 | 474 | 33 | 2.98 / 1287.55 | 2 | 8 |
7 | 13 | 15.00 | 36 | 14.02 | 408 | 206 | 3.18 / 1287.76 | 2 | 9 |
8 | 13 | 2.40 | 36 | 13.97 | 389 | 196 | 3.38 / 1287.95 | 2 | 10 |
9 | 8 | 0.12 | 190 | 13.77 | 374 | 978 | 4.36 / 1288.93 | 2 | 20 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 28 | 13.86 | 515 | 200 | 0.20 / 1278.04 | 2 | 7 |
2 | 10 | 1024.04 | 4 | 13.19 | 1875 | 99 | 0.30 / 1278.14 | 2 | 6 |
3 | 10 | 1067.48 | 3 | 13.20 | 1942 | 77 | 0.38 / 1278.22 | 2 | 5 |
4 | 3 | 864.68 | -3 | 13.20 | 1942 | 0 | 0.18 / 1278.22 | 2 | 5 |
5 | 3 | 920.88 | -2 | 13.20 | 1942 | 0 | 0.18 / 1278.22 | 2 | 5 |
6 | 12 | 1172.00 | 5 | 12.18 | 2072 | 126 | 0.50 / 1278.35 | 2 | 2 |
7 | 12 | 2014.00 | 114 | 10.39 | 3228 | 3823 | 4.33 / 1282.17 | 2 | 2 |
8 | 7 | 1997.00 | 21 | 10.77 | 3200 | 724 | 5.05 / 1282.89 | 2 | 2 |
9 | 13 | 770.12 | 36 | 13.29 | 1439 | 688 | 5.74 / 1283.58 | 2 | 9 |
10 | 8 | 0.28 | 190 | 13.82 | 378 | 993 | 6.73 / 1284.57 | 2 | 13 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 28 | 13.88 | 517 | 201 | 0.20 / 1274.12 | 2 | 6 |
2 | 12 | 1147.88 | 114 | 9.84 | 1987 | 2229 | 2.43 / 1276.34 | 2 | 2 |
3 | 7 | 1135.08 | 21 | 11.13 | 1995 | 466 | 2.90 / 1276.81 | 2 | 3 |
4 | 13 | 176.88 | 5 | 13.98 | 652 | 46 | 2.94 / 1276.86 | 2 | 10 |
5 | 8 | 0.00 | 190 | 13.83 | 376 | 988 | 3.93 / 1277.84 | 2 | 17 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 28 | 13.87 | 516 | 200 | 0.20 / 1270.02 | 2 | 7 |
2 | 12 | 1116.44 | 114 | 10.04 | 1942 | 2223 | 2.42 / 1272.24 | 2 | 2 |
3 | 7 | 1104.80 | 21 | 11.21 | 1952 | 460 | 2.88 / 1272.70 | 2 | 4 |
4 | 13 | 72.04 | 5 | 14.04 | 501 | 35 | 2.92 / 1272.73 | 2 | 8 |
5 | 13 | 14.56 | 36 | 14.00 | 405 | 204 | 3.12 / 1272.94 | 2 | 8 |
6 | 8 | 0.00 | 190 | 13.78 | 373 | 977 | 4.10 / 1273.91 | 2 | 13 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 28 | 13.90 | 523 | 204 | 0.20 / 1265.94 | 2 | 6 |
2 | 12 | 1111.76 | 114 | 9.96 | 1934 | 2196 | 2.40 / 1268.13 | 2 | 2 |
3 | 7 | 1099.40 | 21 | 11.32 | 1930 | 459 | 2.86 / 1268.59 | 2 | 4 |
4 | 13 | 70.24 | 5 | 14.05 | 501 | 35 | 2.89 / 1268.63 | 2 | 8 |
5 | 13 | 3.72 | 36 | 14.03 | 397 | 201 | 3.09 / 1268.83 | 2 | 9 |
6 | 8 | 0.16 | 190 | 13.78 | 378 | 990 | 4.08 / 1269.82 | 2 | 18 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 28 | 13.84 | 517 | 200 | 0.20 / 1260.04 | 2 | 6 |
2 | 3 | 968.44 | -1 | 13.84 | 517 | 0 | 0.00 / 1260.04 | 2 | 6 |
3 | 3 | 1020.60 | 1 | 12.54 | 1887 | 24 | 0.22 / 1260.07 | 2 | 2 |
4 | 12 | 1128.72 | 5 | 12.32 | 2016 | 124 | 0.35 / 1260.19 | 2 | 2 |
5 | 12 | 1959.72 | 114 | 10.46 | 3141 | 3745 | 4.09 / 1263.94 | 2 | 2 |
6 | 7 | 1933.76 | 20 | 10.85 | 3122 | 677 | 4.77 / 1264.61 | 2 | 2 |
7 | 13 | 129.12 | 5 | 14.03 | 579 | 41 | 4.81 / 1264.65 | 2 | 9 |
8 | 13 | 84.36 | 5 | 14.03 | 510 | 36 | 4.85 / 1264.69 | 2 | 8 |
9 | 13 | 44.32 | 5 | 14.07 | 465 | 33 | 4.88 / 1264.72 | 2 | 9 |
10 | 13 | 41.20 | 5 | 14.02 | 453 | 32 | 4.91 / 1264.76 | 2 | 9 |
11 | 8 | 0.04 | 190 | 13.83 | 372 | 978 | 5.89 / 1265.73 | 2 | 11 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 29 | 13.86 | 518 | 208 | 0.21 / 1255.97 | 2 | 6 |
2 | 3 | 952.36 | -1 | 13.86 | 518 | 0 | 0.00 / 1255.97 | 2 | 6 |
3 | 12 | 1137.64 | 114 | 9.94 | 1968 | 2230 | 2.44 / 1258.20 | 2 | 2 |
4 | 7 | 1126.08 | 21 | 11.15 | 1978 | 463 | 2.90 / 1258.67 | 2 | 4 |
5 | 13 | 2.88 | 36 | 14.02 | 390 | 197 | 3.10 / 1258.86 | 2 | 7 |
6 | 8 | -0.08 | 190 | 13.77 | 375 | 981 | 4.08 / 1259.84 | 2 | 14 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 27 | 13.86 | 533 | 199 | 0.20 / 1251.86 | 2 | 6 |
2 | 3 | 1028.56 | 1 | 12.93 | 1910 | 25 | 0.22 / 1251.89 | 2 | 2 |
3 | 12 | 1129.08 | 114 | 9.95 | 1959 | 2222 | 2.45 / 1254.11 | 2 | 2 |
4 | 7 | 1118.16 | 21 | 11.19 | 1973 | 464 | 2.91 / 1254.57 | 2 | 4 |
5 | 13 | 3.72 | 36 | 14.00 | 399 | 201 | 3.11 / 1254.78 | 2 | 8 |
6 | 8 | 0.08 | 190 | 13.76 | 378 | 988 | 4.10 / 1255.76 | 2 | 17 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 28 | 13.86 | 531 | 206 | 0.21 / 1247.78 | 2 | 7 |
2 | 3 | 951.44 | -1 | 13.86 | 531 | 0 | 0.00 / 1247.78 | 2 | 7 |
3 | 12 | 1128.72 | 114 | 9.91 | 1956 | 2210 | 2.42 / 1249.99 | 2 | 2 |
4 | 7 | 1116.60 | 21 | 11.28 | 1966 | 466 | 2.88 / 1250.45 | 2 | 4 |
5 | 13 | 43.32 | 5 | 14.07 | 460 | 32 | 2.91 / 1250.48 | 2 | 8 |
6 | 13 | 15.08 | 36 | 14.01 | 404 | 204 | 3.12 / 1250.69 | 2 | 6 |
7 | 8 | -0.04 | 190 | 13.77 | 373 | 976 | 4.09 / 1251.66 | 2 | 12 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 28 | 13.83 | 508 | 197 | 0.20 / 1241.50 | 2 | 5 |
2 | 12 | 1130.80 | 5 | 12.31 | 2009 | 124 | 0.32 / 1241.62 | 2 | 2 |
3 | 12 | 1990.24 | 114 | 10.37 | 3189 | 3770 | 4.09 / 1245.39 | 2 | 2 |
4 | 7 | 1966.52 | 21 | 10.80 | 3169 | 719 | 4.81 / 1246.11 | 2 | 2 |
5 | 13 | 111.28 | 5 | 14.02 | 548 | 38 | 4.85 / 1246.15 | 2 | 8 |
6 | 13 | 79.88 | 5 | 14.05 | 506 | 36 | 4.88 / 1246.19 | 2 | 8 |
7 | 13 | 60.72 | 5 | 14.04 | 475 | 33 | 4.92 / 1246.22 | 2 | 8 |
8 | 13 | 16.44 | 36 | 14.00 | 401 | 202 | 5.12 / 1246.42 | 2 | 7 |
9 | 13 | 3.28 | 36 | 13.96 | 379 | 190 | 5.31 / 1246.61 | 2 | 6 |
10 | 8 | 0.08 | 190 | 13.78 | 366 | 958 | 6.27 / 1247.57 | 2 | 18 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 27 | 13.87 | 503 | 188 | 0.19 / 1237.60 | 2 | 4 |
2 | 3 | 1059.04 | 2 | 12.97 | 1952 | 51 | 0.24 / 1237.65 | 2 | 2 |
3 | 12 | 1112.08 | 114 | 9.91 | 1936 | 2187 | 2.43 / 1239.84 | 2 | 2 |
4 | 7 | 1100.60 | 21 | 11.18 | 1935 | 454 | 2.88 / 1240.29 | 2 | 4 |
5 | 13 | 78.20 | 5 | 14.00 | 505 | 35 | 2.92 / 1240.33 | 2 | 8 |
6 | 8 | 0.24 | 190 | 13.81 | 372 | 976 | 3.89 / 1241.30 | 2 | 13 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 28 | 13.86 | 509 | 198 | 0.20 / 1233.77 | 2 | 5 |
2 | 12 | 1099.08 | 114 | 10.08 | 1915 | 2201 | 2.40 / 1235.97 | 2 | 2 |
3 | 7 | 1087.32 | 21 | 11.25 | 1918 | 453 | 2.85 / 1236.43 | 2 | 4 |
4 | 8 | 0.24 | 190 | 13.82 | 375 | 985 | 3.84 / 1237.41 | 2 | 14 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 28 | 13.85 | 523 | 203 | 0.20 / 1229.70 | 2 | 4 |
2 | 12 | 1101.16 | 114 | 9.94 | 1919 | 2175 | 2.38 / 1231.87 | 2 | 2 |
3 | 7 | 1090.56 | 21 | 11.31 | 1930 | 458 | 2.84 / 1232.33 | 2 | 4 |
4 | 13 | 46.60 | 5 | 14.06 | 468 | 33 | 2.87 / 1232.37 | 2 | 8 |
5 | 13 | 43.32 | 5 | 14.02 | 460 | 32 | 2.90 / 1232.40 | 2 | 8 |
6 | 13 | 12.60 | 36 | 13.99 | 401 | 202 | 3.10 / 1232.60 | 2 | 7 |
7 | 8 | 0.40 | 190 | 13.77 | 373 | 976 | 4.08 / 1233.58 | 2 | 12 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 28 | 13.87 | 501 | 195 | 0.19 / 1223.63 | 2 | 4 |
2 | 12 | 1096.92 | 5 | 12.32 | 1965 | 121 | 0.32 / 1223.75 | 2 | 2 |
3 | 12 | 1998.28 | 114 | 10.27 | 3203 | 3750 | 4.07 / 1227.50 | 2 | 2 |
4 | 7 | 1975.28 | 21 | 10.75 | 3197 | 722 | 4.79 / 1228.22 | 2 | 2 |
5 | 13 | 128.96 | 5 | 13.99 | 581 | 41 | 4.83 / 1228.26 | 2 | 9 |
6 | 13 | 85.96 | 5 | 14.05 | 518 | 36 | 4.86 / 1228.30 | 2 | 8 |
7 | 13 | 49.72 | 5 | 14.07 | 468 | 33 | 4.90 / 1228.33 | 2 | 8 |
8 | 13 | 2.36 | 36 | 14.02 | 387 | 195 | 5.09 / 1228.53 | 2 | 4 |
9 | 8 | 0.00 | 190 | 13.79 | 370 | 969 | 6.06 / 1229.50 | 2 | 13 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 28 | 13.86 | 516 | 200 | 0.20 / 1219.55 | 2 | 5 |
2 | 3 | 960.64 | -1 | 13.86 | 516 | 0 | 0.00 / 1219.55 | 2 | 5 |
3 | 12 | 1132.92 | 114 | 9.91 | 1965 | 2220 | 2.42 / 1221.77 | 2 | 2 |
4 | 7 | 1120.60 | 21 | 11.19 | 1968 | 462 | 2.88 / 1222.24 | 2 | 3 |
5 | 13 | 75.96 | 5 | 13.99 | 502 | 35 | 2.92 / 1222.27 | 2 | 8 |
6 | 13 | 16.48 | 36 | 13.98 | 399 | 201 | 3.12 / 1222.47 | 2 | 6 |
7 | 8 | -0.08 | 190 | 13.80 | 367 | 962 | 4.08 / 1223.44 | 2 | 17 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 28 | 13.89 | 510 | 198 | 0.20 / 1215.53 | 2 | 5 |
2 | 12 | 1108.24 | 114 | 10.00 | 1933 | 2204 | 2.40 / 1217.73 | 2 | 2 |
3 | 7 | 1096.56 | 21 | 11.23 | 1938 | 457 | 2.86 / 1218.19 | 2 | 4 |
4 | 13 | 3.20 | 36 | 13.99 | 386 | 194 | 3.05 / 1218.38 | 2 | 11 |
5 | 8 | 0.20 | 190 | 13.76 | 371 | 970 | 4.02 / 1219.35 | 2 | 17 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 29 | 13.83 | 506 | 203 | 0.20 / 1211.67 | 2 | 4 |
2 | 3 | 946.68 | -1 | 13.83 | 506 | 0 | 0.00 / 1211.67 | 2 | 4 |
3 | 3 | 1028.24 | 1 | 12.35 | 1894 | 23 | 0.23 / 1211.69 | 2 | 2 |
4 | 12 | 1115.32 | 114 | 9.90 | 1930 | 2178 | 2.40 / 1213.87 | 2 | 2 |
5 | 7 | 1105.16 | 21 | 11.25 | 1948 | 460 | 2.86 / 1214.33 | 2 | 3 |
6 | 13 | 42.56 | 5 | 14.04 | 452 | 32 | 2.90 / 1214.36 | 2 | 7 |
7 | 8 | -0.20 | 190 | 13.83 | 368 | 967 | 3.86 / 1215.33 | 2 | 14 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 28 | 13.85 | 517 | 200 | 0.20 / 1207.54 | 2 | 5 |
2 | 12 | 1084.04 | 5 | 12.44 | 1941 | 121 | 0.32 / 1207.66 | 2 | 4 |
3 | 12 | 1028.08 | 114 | 11.81 | 1788 | 2407 | 2.73 / 1210.07 | 2 | 5 |
4 | 7 | 1002.96 | 21 | 11.60 | 1799 | 438 | 3.17 / 1210.50 | 5 | 7 |
5 | 8 | 0.00 | 190 | 13.82 | 367 | 964 | 4.13 / 1211.47 | 2 | 17 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 28 | 13.85 | 508 | 197 | 0.20 / 1203.67 | 2 | 4 |
2 | 12 | 1113.36 | 114 | 10.06 | 1932 | 2216 | 2.41 / 1205.89 | 2 | 2 |
3 | 7 | 1099.28 | 21 | 11.27 | 1940 | 459 | 2.87 / 1206.35 | 2 | 4 |
4 | 13 | 50.48 | 5 | 14.03 | 465 | 33 | 2.90 / 1206.38 | 2 | 8 |
5 | 8 | 0.48 | 190 | 13.82 | 364 | 956 | 3.86 / 1207.34 | 2 | 12 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 29 | 13.84 | 513 | 206 | 0.21 / 1199.77 | 2 | 4 |
2 | 12 | 1133.36 | 114 | 10.07 | 1962 | 2252 | 2.46 / 1202.02 | 2 | 2 |
3 | 7 | 1123.72 | 21 | 11.29 | 1971 | 467 | 2.93 / 1202.49 | 2 | 4 |
4 | 13 | 74.60 | 5 | 14.03 | 499 | 35 | 2.96 / 1202.53 | 2 | 8 |
5 | 8 | 0.04 | 190 | 13.83 | 362 | 951 | 3.91 / 1203.48 | 2 | 12 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 29 | 13.89 | 493 | 199 | 0.20 / 1195.84 | 2 | 3 |
2 | 12 | 1126.20 | 114 | 9.97 | 1951 | 2217 | 2.42 / 1198.06 | 2 | 2 |
3 | 7 | 1117.60 | 21 | 11.36 | 1962 | 468 | 2.88 / 1198.52 | 2 | 4 |
4 | 13 | 104.28 | 5 | 14.01 | 547 | 38 | 2.92 / 1198.56 | 2 | 9 |
5 | 13 | 69.20 | 5 | 14.01 | 492 | 34 | 2.96 / 1198.60 | 2 | 7 |
6 | 8 | 0.24 | 190 | 13.82 | 369 | 969 | 3.93 / 1199.57 | 2 | 11 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 28 | 13.84 | 504 | 195 | 0.20 / 1189.90 | 2 | 4 |
2 | 12 | 1104.24 | 5 | 12.38 | 1969 | 122 | 0.32 / 1190.02 | 2 | 2 |
3 | 12 | 1989.60 | 114 | 10.36 | 3185 | 3762 | 4.08 / 1193.78 | 2 | 2 |
4 | 7 | 1967.36 | 20 | 10.87 | 3166 | 688 | 4.77 / 1194.47 | 2 | 2 |
5 | 13 | 245.32 | 5 | 13.91 | 758 | 53 | 4.82 / 1194.52 | 2 | 9 |
6 | 13 | 132.84 | 5 | 13.97 | 593 | 41 | 4.86 / 1194.56 | 2 | 8 |
7 | 13 | 61.08 | 5 | 14.02 | 485 | 34 | 4.90 / 1194.60 | 2 | 7 |
8 | 13 | 45.12 | 5 | 14.02 | 468 | 33 | 4.93 / 1194.63 | 2 | 7 |
9 | 13 | 41.84 | 5 | 13.99 | 458 | 32 | 4.96 / 1194.66 | 2 | 8 |
10 | 8 | 0.24 | 190 | 13.81 | 372 | 976 | 5.94 / 1195.64 | 2 | 14 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 27 | 13.87 | 500 | 187 | 0.19 / 1185.77 | 2 | 3 |
2 | 3 | 1021.44 | 1 | 12.61 | 1899 | 24 | 0.21 / 1185.79 | 2 | 2 |
3 | 12 | 1128.04 | 114 | 10.03 | 1953 | 2233 | 2.44 / 1188.02 | 2 | 2 |
4 | 7 | 1114.08 | 21 | 11.32 | 1957 | 465 | 2.91 / 1188.49 | 2 | 3 |
5 | 13 | 75.64 | 5 | 13.99 | 508 | 36 | 2.95 / 1188.52 | 2 | 8 |
6 | 13 | 16.16 | 36 | 13.97 | 404 | 203 | 3.15 / 1188.73 | 2 | 6 |
7 | 8 | -0.08 | 190 | 13.73 | 374 | 976 | 4.12 / 1189.70 | 2 | 16 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 28 | 13.87 | 498 | 193 | 0.19 / 1181.69 | 2 | 4 |
2 | 3 | 1018.92 | 1 | 12.77 | 1868 | 24 | 0.22 / 1181.71 | 2 | 2 |
3 | 12 | 1115.96 | 114 | 10.09 | 1936 | 2227 | 2.44 / 1183.94 | 2 | 2 |
4 | 7 | 1104.24 | 21 | 11.33 | 1941 | 462 | 2.91 / 1184.40 | 2 | 3 |
5 | 13 | 55.52 | 5 | 14.03 | 473 | 33 | 2.94 / 1184.43 | 2 | 7 |
6 | 13 | 16.00 | 36 | 13.99 | 390 | 196 | 3.14 / 1184.63 | 2 | 5 |
7 | 8 | 0.08 | 190 | 13.76 | 363 | 949 | 4.08 / 1185.58 | 2 | 14 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 27 | 13.83 | 503 | 188 | 0.19 / 1177.86 | 2 | 3 |
2 | 12 | 1103.16 | 114 | 10.01 | 1918 | 2189 | 2.38 / 1180.05 | 2 | 2 |
3 | 7 | 1090.56 | 21 | 11.42 | 1921 | 461 | 2.84 / 1180.51 | 2 | 4 |
4 | 13 | 54.76 | 5 | 14.04 | 476 | 33 | 2.87 / 1180.54 | 2 | 7 |
5 | 8 | 0.20 | 190 | 13.82 | 363 | 953 | 3.82 / 1181.49 | 2 | 11 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 26 | 13.85 | 493 | 178 | 0.18 / 1171.82 | 2 | 3 |
2 | 3 | 1058.20 | 2 | 12.97 | 1933 | 50 | 0.23 / 1171.87 | 2 | 2 |
3 | 12 | 1116.20 | 5 | 12.30 | 2000 | 123 | 0.35 / 1171.99 | 2 | 2 |
4 | 12 | 1990.64 | 114 | 10.33 | 3172 | 3735 | 4.09 / 1175.73 | 2 | 2 |
5 | 7 | 1968.28 | 21 | 10.82 | 3182 | 723 | 4.81 / 1176.45 | 2 | 2 |
6 | 13 | 136.56 | 5 | 13.98 | 584 | 41 | 4.85 / 1176.49 | 2 | 8 |
7 | 13 | 88.28 | 5 | 14.00 | 512 | 36 | 4.89 / 1176.52 | 2 | 7 |
8 | 13 | 15.96 | 36 | 13.99 | 392 | 197 | 5.08 / 1176.72 | 2 | 6 |
9 | 8 | 0.20 | 190 | 13.79 | 362 | 948 | 6.03 / 1177.67 | 2 | 12 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 26 | 13.85 | 513 | 185 | 0.18 / 1167.79 | 2 | 4 |
2 | 3 | 1061.64 | 2 | 13.01 | 1939 | 50 | 0.24 / 1167.84 | 2 | 2 |
3 | 12 | 1091.80 | 114 | 10.08 | 1899 | 2182 | 2.42 / 1170.02 | 2 | 2 |
4 | 7 | 1080.72 | 21 | 11.35 | 1906 | 454 | 2.87 / 1170.48 | 2 | 3 |
5 | 13 | 44.96 | 36 | 13.93 | 427 | 214 | 3.09 / 1170.69 | 2 | 6 |
6 | 8 | -0.20 | 190 | 13.79 | 361 | 946 | 4.03 / 1171.64 | 2 | 16 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 26 | 13.88 | 496 | 179 | 0.18 / 1163.71 | 2 | 4 |
2 | 3 | 1046.52 | 1 | 13.01 | 1920 | 25 | 0.20 / 1163.73 | 2 | 2 |
3 | 12 | 1125.32 | 114 | 10.10 | 1945 | 2239 | 2.44 / 1165.97 | 2 | 2 |
4 | 7 | 1112.48 | 21 | 11.37 | 1947 | 465 | 2.91 / 1166.44 | 2 | 3 |
5 | 13 | 54.00 | 36 | 13.94 | 438 | 220 | 3.13 / 1166.66 | 2 | 6 |
6 | 8 | 0.08 | 190 | 13.82 | 362 | 951 | 4.08 / 1167.61 | 2 | 17 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 26 | 13.88 | 509 | 184 | 0.18 / 1159.72 | 2 | 4 |
2 | 12 | 1069.52 | 114 | 10.13 | 1866 | 2155 | 2.34 / 1161.88 | 2 | 2 |
3 | 7 | 1057.76 | 21 | 11.49 | 1873 | 452 | 2.79 / 1162.33 | 2 | 4 |
4 | 13 | 94.48 | 36 | 13.91 | 486 | 243 | 3.03 / 1162.57 | 2 | 6 |
5 | 8 | 0.36 | 190 | 13.85 | 363 | 955 | 3.99 / 1163.53 | 2 | 18 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 27 | 13.86 | 506 | 189 | 0.19 / 1153.37 | 2 | 4 |
2 | 3 | 952.24 | -1 | 13.86 | 506 | 0 | 0.00 / 1153.37 | 2 | 4 |
3 | 3 | 1028.24 | 1 | 12.66 | 1892 | 24 | 0.21 / 1153.40 | 2 | 2 |
4 | 12 | 1140.20 | 5 | 12.29 | 2026 | 124 | 0.34 / 1153.52 | 2 | 2 |
5 | 12 | 2003.68 | 114 | 10.36 | 3195 | 3773 | 4.11 / 1157.29 | 2 | 2 |
6 | 7 | 1980.04 | 21 | 10.91 | 3186 | 730 | 4.84 / 1158.02 | 2 | 2 |
7 | 13 | 308.48 | 36 | 13.72 | 778 | 384 | 5.23 / 1158.41 | 2 | 7 |
8 | 13 | 4.64 | 36 | 14.02 | 374 | 189 | 5.41 / 1158.60 | 2 | 13 |
9 | 8 | -0.16 | 190 | 13.89 | 357 | 942 | 6.36 / 1159.54 | 2 | 18 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 26 | 13.85 | 504 | 181 | 0.18 / 1149.22 | 2 | 4 |
2 | 3 | 968.92 | -1 | 13.85 | 504 | 0 | 0.00 / 1149.22 | 2 | 4 |
3 | 3 | 1025.72 | 1 | 12.59 | 1886 | 24 | 0.21 / 1149.24 | 2 | 2 |
4 | 12 | 1146.52 | 114 | 10.05 | 1974 | 2262 | 2.47 / 1151.51 | 2 | 2 |
5 | 7 | 1136.20 | 21 | 11.36 | 1972 | 470 | 2.94 / 1151.98 | 2 | 3 |
6 | 13 | 141.32 | 36 | 13.86 | 545 | 272 | 3.21 / 1152.25 | 2 | 8 |
7 | 8 | 0.32 | 190 | 13.87 | 355 | 936 | 4.14 / 1153.18 | 2 | 17 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 26 | 13.89 | 506 | 183 | 0.18 / 1145.25 | 2 | 4 |
2 | 12 | 1124.36 | 114 | 10.07 | 1941 | 2228 | 2.41 / 1147.48 | 2 | 2 |
3 | 7 | 1113.56 | 20 | 11.44 | 1948 | 446 | 2.86 / 1147.93 | 2 | 3 |
4 | 13 | 29.40 | 36 | 13.98 | 394 | 198 | 3.05 / 1148.12 | 2 | 7 |
5 | 8 | -0.04 | 190 | 13.88 | 347 | 915 | 3.97 / 1149.04 | 2 | 15 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 27 | 13.86 | 512 | 192 | 0.19 / 1141.17 | 2 | 5 |
2 | 3 | 945.32 | -1 | 13.86 | 512 | 0 | 0.00 / 1141.17 | 2 | 5 |
3 | 12 | 1154.40 | 114 | 9.98 | 1981 | 2254 | 2.45 / 1143.42 | 2 | 2 |
4 | 7 | 1144.44 | 21 | 11.42 | 1994 | 478 | 2.92 / 1143.90 | 2 | 3 |
5 | 13 | 71.36 | 36 | 13.94 | 458 | 230 | 3.15 / 1144.13 | 2 | 6 |
6 | 8 | 0.40 | 190 | 13.87 | 356 | 938 | 4.09 / 1145.07 | 2 | 16 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 27 | 13.83 | 514 | 192 | 0.19 / 1135.16 | 2 | 4 |
2 | 12 | 1102.00 | 5 | 12.36 | 1963 | 121 | 0.31 / 1135.29 | 2 | 2 |
3 | 12 | 2001.48 | 114 | 10.39 | 3190 | 3778 | 4.09 / 1139.06 | 2 | 2 |
4 | 7 | 1980.44 | 21 | 10.92 | 3176 | 728 | 4.82 / 1139.79 | 2 | 2 |
5 | 13 | 68.92 | 36 | 13.92 | 460 | 231 | 5.05 / 1140.02 | 2 | 6 |
6 | 8 | 0.04 | 190 | 13.87 | 362 | 954 | 6.00 / 1140.98 | 2 | 21 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 27 | 13.87 | 498 | 186 | 0.19 / 1131.08 | 2 | 4 |
2 | 3 | 954.24 | -1 | 13.87 | 498 | 0 | 0.00 / 1131.08 | 2 | 4 |
3 | 12 | 1116.80 | 114 | 10.07 | 1935 | 2221 | 2.41 / 1133.30 | 2 | 2 |
4 | 7 | 1105.92 | 21 | 11.37 | 1948 | 465 | 2.87 / 1133.77 | 2 | 3 |
5 | 13 | 125.48 | 36 | 13.86 | 527 | 263 | 3.14 / 1134.03 | 2 | 7 |
6 | 8 | 0.40 | 190 | 13.84 | 358 | 941 | 4.08 / 1134.97 | 2 | 24 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 27 | 13.83 | 516 | 193 | 0.19 / 1127.07 | 2 | 5 |
2 | 12 | 1115.20 | 114 | 10.08 | 1934 | 2222 | 2.42 / 1129.30 | 2 | 2 |
3 | 7 | 1108.72 | 20 | 11.42 | 1954 | 446 | 2.86 / 1129.74 | 2 | 3 |
4 | 13 | 56.88 | 36 | 13.93 | 435 | 218 | 3.08 / 1129.96 | 2 | 7 |
5 | 8 | -0.28 | 190 | 13.85 | 355 | 934 | 4.01 / 1130.90 | 2 | 18 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 28 | 13.82 | 502 | 194 | 0.19 / 1123.16 | 2 | 5 |
2 | 3 | 962.24 | -1 | 13.82 | 502 | 0 | 0.00 / 1123.16 | 2 | 5 |
3 | 12 | 1106.96 | 78 | 10.27 | 1923 | 1540 | 1.73 / 1124.70 | 2 | 2 |
4 | 7 | 1103.00 | 21 | 11.59 | 1938 | 472 | 2.21 / 1125.17 | 2 | 3 |
5 | 13 | 898.32 | 36 | 13.10 | 1634 | 771 | 2.98 / 1125.94 | 2 | 6 |
6 | 8 | 0.80 | 190 | 13.87 | 356 | 938 | 3.92 / 1126.88 | 2 | 21 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 27 | 13.81 | 524 | 195 | 0.20 / 1117.85 | 2 | 4 |
2 | 10 | 1001.56 | 4 | 13.24 | 1834 | 97 | 0.29 / 1117.95 | 2 | 5 |
3 | 3 | 893.92 | -2 | 13.24 | 1834 | 0 | 0.10 / 1117.95 | 2 | 5 |
4 | 3 | 973.44 | -1 | 13.24 | 1834 | 0 | 0.10 / 1117.95 | 2 | 5 |
5 | 12 | 1101.96 | 5 | 12.45 | 1964 | 122 | 0.41 / 1118.07 | 2 | 2 |
6 | 12 | 1986.36 | 78 | 10.58 | 3172 | 2618 | 3.03 / 1120.69 | 2 | 2 |
7 | 7 | 1967.04 | 21 | 10.97 | 3152 | 726 | 3.76 / 1121.42 | 2 | 2 |
8 | 13 | 627.88 | 36 | 13.38 | 1240 | 597 | 4.36 / 1122.01 | 2 | 7 |
9 | 8 | 0.28 | 190 | 13.88 | 361 | 952 | 5.31 / 1122.97 | 2 | 17 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 28 | 13.83 | 515 | 199 | 0.20 / 1114.07 | 2 | 5 |
2 | 3 | 968.32 | -1 | 13.83 | 515 | 0 | 0.00 / 1114.07 | 2 | 5 |
3 | 12 | 1132.08 | 78 | 10.12 | 1955 | 1543 | 1.74 / 1115.61 | 2 | 2 |
4 | 7 | 1130.60 | 21 | 11.50 | 1976 | 477 | 2.22 / 1116.09 | 2 | 3 |
5 | 13 | 686.84 | 36 | 13.30 | 1321 | 632 | 2.85 / 1116.72 | 2 | 7 |
6 | 8 | -0.08 | 190 | 13.85 | 357 | 939 | 3.79 / 1117.66 | 2 | 17 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 27 | 13.81 | 504 | 188 | 0.19 / 1110.27 | 2 | 4 |
2 | 3 | 1045.08 | 1 | 13.02 | 1914 | 25 | 0.21 / 1110.30 | 2 | 2 |
3 | 12 | 1125.08 | 78 | 10.20 | 1946 | 1548 | 1.76 / 1111.85 | 2 | 2 |
4 | 7 | 1120.04 | 21 | 11.55 | 1961 | 476 | 2.24 / 1112.32 | 2 | 3 |
5 | 13 | 661.44 | 36 | 13.33 | 1281 | 615 | 2.85 / 1112.94 | 2 | 7 |
6 | 8 | 0.12 | 190 | 13.87 | 353 | 930 | 3.78 / 1113.87 | 2 | 19 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 29 | 13.83 | 508 | 204 | 0.20 / 1106.58 | 2 | 4 |
2 | 3 | 936.12 | -1 | 13.83 | 508 | 0 | 0.00 / 1106.58 | 2 | 4 |
3 | 12 | 1100.52 | 78 | 10.31 | 1917 | 1542 | 1.75 / 1108.12 | 2 | 2 |
4 | 7 | 1096.76 | 21 | 11.66 | 1929 | 472 | 2.22 / 1108.60 | 2 | 3 |
5 | 13 | 422.72 | 30 | 13.62 | 937 | 383 | 2.60 / 1108.98 | 2 | 7 |
6 | 13 | 15.68 | 30 | 13.99 | 387 | 162 | 2.76 / 1109.14 | 2 | 6 |
7 | 8 | -0.04 | 190 | 13.84 | 359 | 944 | 3.71 / 1110.08 | 2 | 21 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 29 | 13.82 | 498 | 200 | 0.20 / 1101.10 | 2 | 4 |
2 | 3 | 927.44 | -1 | 13.82 | 498 | 0 | 0.00 / 1101.10 | 2 | 4 |
3 | 3 | 962.64 | -1 | 13.82 | 498 | 0 | 0.00 / 1101.10 | 2 | 4 |
4 | 12 | 1133.40 | 5 | 12.48 | 2009 | 125 | 0.32 / 1101.23 | 2 | 2 |
5 | 12 | 2000.28 | 78 | 10.61 | 3189 | 2639 | 2.96 / 1103.87 | 2 | 2 |
6 | 7 | 1984.52 | 21 | 10.97 | 3194 | 736 | 3.70 / 1104.60 | 2 | 2 |
7 | 13 | 916.80 | 30 | 13.18 | 1651 | 653 | 4.35 / 1105.26 | 2 | 6 |
8 | 13 | 37.12 | 30 | 14.00 | 410 | 172 | 4.52 / 1105.43 | 2 | 5 |
9 | 8 | 0.00 | 190 | 13.90 | 359 | 948 | 5.47 / 1106.38 | 2 | 20 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 28 | 13.84 | 510 | 198 | 0.20 / 1097.35 | 2 | 4 |
2 | 12 | 1087.36 | 78 | 10.30 | 1895 | 1522 | 1.72 / 1098.87 | 2 | 2 |
3 | 7 | 1083.52 | 21 | 11.61 | 1907 | 465 | 2.19 / 1099.33 | 2 | 3 |
4 | 13 | 613.36 | 30 | 13.41 | 1212 | 488 | 2.67 / 1099.82 | 2 | 7 |
5 | 13 | 14.44 | 30 | 14.00 | 377 | 158 | 2.83 / 1099.98 | 2 | 7 |
6 | 8 | 0.16 | 190 | 13.84 | 352 | 926 | 3.76 / 1100.90 | 2 | 19 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 28 | 13.85 | 490 | 190 | 0.19 / 1093.43 | 2 | 3 |
2 | 3 | 1028.24 | 1 | 12.82 | 1884 | 24 | 0.21 / 1093.46 | 2 | 2 |
3 | 12 | 1149.04 | 78 | 10.19 | 1973 | 1568 | 1.78 / 1095.03 | 2 | 2 |
4 | 7 | 1145.96 | 21 | 11.58 | 2001 | 487 | 2.27 / 1095.51 | 2 | 3 |
5 | 13 | 690.64 | 30 | 13.36 | 1336 | 535 | 2.80 / 1096.05 | 2 | 6 |
6 | 13 | 15.04 | 30 | 14.02 | 381 | 160 | 2.96 / 1096.21 | 2 | 6 |
7 | 8 | 0.24 | 190 | 13.86 | 357 | 940 | 3.90 / 1097.15 | 2 | 18 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 29 | 13.83 | 500 | 201 | 0.20 / 1089.66 | 2 | 5 |
2 | 3 | 937.72 | -1 | 13.83 | 500 | 0 | 0.00 / 1089.66 | 2 | 5 |
3 | 12 | 1086.16 | 78 | 10.35 | 1895 | 1530 | 1.73 / 1091.19 | 2 | 2 |
4 | 7 | 1085.12 | 21 | 11.44 | 1904 | 457 | 2.19 / 1091.64 | 2 | 3 |
5 | 13 | 625.48 | 30 | 13.42 | 1254 | 505 | 2.69 / 1092.15 | 2 | 7 |
6 | 13 | 5.04 | 30 | 14.01 | 376 | 158 | 2.85 / 1092.31 | 2 | 8 |
7 | 8 | 0.60 | 190 | 13.86 | 356 | 937 | 3.79 / 1093.24 | 2 | 15 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 29 | 13.81 | 494 | 198 | 0.20 / 1084.29 | 2 | 4 |
2 | 3 | 1024.80 | 1 | 12.79 | 1873 | 24 | 0.22 / 1084.31 | 2 | 2 |
3 | 12 | 1117.32 | 5 | 12.55 | 1995 | 125 | 0.35 / 1084.44 | 2 | 2 |
4 | 12 | 2000.20 | 78 | 10.71 | 3194 | 2668 | 3.02 / 1087.11 | 2 | 2 |
5 | 7 | 1989.00 | 20 | 10.82 | 3191 | 691 | 3.71 / 1087.80 | 2 | 2 |
6 | 13 | 723.88 | 30 | 13.34 | 1384 | 554 | 4.26 / 1088.35 | 2 | 7 |
7 | 13 | 6.36 | 30 | 14.03 | 376 | 158 | 4.42 / 1088.51 | 2 | 10 |
8 | 8 | 0.28 | 190 | 13.87 | 359 | 946 | 5.36 / 1089.46 | 2 | 23 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 29 | 13.82 | 501 | 201 | 0.20 / 1080.61 | 2 | 5 |
2 | 3 | 944.16 | -1 | 13.82 | 501 | 0 | 0.00 / 1080.61 | 2 | 5 |
3 | 12 | 1137.00 | 78 | 10.24 | 1956 | 1562 | 1.76 / 1082.17 | 2 | 2 |
4 | 7 | 1137.00 | 21 | 11.32 | 1980 | 471 | 2.23 / 1082.64 | 2 | 3 |
5 | 13 | 674.80 | 30 | 13.35 | 1299 | 520 | 2.75 / 1083.16 | 2 | 6 |
6 | 8 | 0.04 | 190 | 13.86 | 354 | 932 | 3.69 / 1084.09 | 2 | 19 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 29 | 13.82 | 504 | 202 | 0.20 / 1077.04 | 2 | 4 |
2 | 12 | 1130.00 | 78 | 10.29 | 1952 | 1567 | 1.77 / 1078.60 | 2 | 2 |
3 | 7 | 1128.84 | 21 | 11.36 | 1967 | 469 | 2.24 / 1079.07 | 2 | 3 |
4 | 13 | 453.16 | 30 | 13.57 | 984 | 401 | 2.64 / 1079.47 | 2 | 7 |
5 | 8 | 0.24 | 190 | 13.86 | 354 | 932 | 3.57 / 1080.41 | 2 | 17 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 29 | 13.82 | 504 | 202 | 0.20 / 1073.46 | 2 | 4 |
2 | 12 | 1121.12 | 60 | 10.52 | 1948 | 1230 | 1.43 / 1074.69 | 2 | 2 |
3 | 7 | 1122.28 | 21 | 11.61 | 1968 | 480 | 1.91 / 1075.17 | 2 | 3 |
4 | 13 | 710.20 | 30 | 13.34 | 1354 | 542 | 2.45 / 1075.71 | 2 | 6 |
5 | 13 | 53.76 | 30 | 13.95 | 433 | 181 | 2.63 / 1075.89 | 2 | 6 |
6 | 8 | 0.04 | 190 | 13.87 | 358 | 943 | 3.58 / 1076.83 | 2 | 15 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 28 | 13.79 | 497 | 192 | 0.19 / 1068.39 | 2 | 4 |
2 | 12 | 1125.84 | 5 | 12.57 | 2003 | 126 | 0.32 / 1068.52 | 2 | 2 |
3 | 12 | 1991.68 | 60 | 10.83 | 3183 | 2068 | 2.39 / 1070.59 | 2 | 2 |
4 | 7 | 1982.88 | 21 | 10.82 | 3176 | 722 | 3.11 / 1071.31 | 2 | 2 |
5 | 13 | 1015.12 | 30 | 13.08 | 1786 | 701 | 3.81 / 1072.01 | 2 | 5 |
6 | 13 | 273.28 | 30 | 13.74 | 732 | 302 | 4.11 / 1072.31 | 2 | 8 |
7 | 8 | 0.08 | 190 | 13.87 | 359 | 946 | 5.06 / 1073.26 | 2 | 14 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 29 | 13.81 | 505 | 202 | 0.20 / 1064.53 | 2 | 3 |
2 | 12 | 1112.44 | 60 | 10.33 | 1937 | 1201 | 1.40 / 1065.73 | 2 | 2 |
3 | 7 | 1114.92 | 21 | 11.55 | 1958 | 475 | 1.88 / 1066.21 | 2 | 3 |
4 | 13 | 902.52 | 30 | 13.09 | 1643 | 645 | 2.52 / 1066.85 | 2 | 5 |
5 | 13 | 154.80 | 30 | 13.83 | 567 | 235 | 2.76 / 1067.09 | 2 | 7 |
6 | 13 | 4.76 | 30 | 13.99 | 377 | 158 | 2.92 / 1067.25 | 2 | 12 |
7 | 8 | 0.04 | 190 | 13.79 | 364 | 954 | 3.87 / 1068.20 | 2 | 17 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 29 | 13.83 | 489 | 196 | 0.20 / 1060.86 | 2 | 3 |
2 | 12 | 1107.92 | 60 | 10.42 | 1935 | 1210 | 1.41 / 1062.07 | 2 | 2 |
3 | 7 | 1110.52 | 21 | 11.61 | 1947 | 475 | 1.88 / 1062.55 | 2 | 3 |
4 | 13 | 892.40 | 30 | 13.14 | 1630 | 643 | 2.52 / 1063.19 | 2 | 6 |
5 | 13 | 91.48 | 30 | 13.92 | 477 | 199 | 2.72 / 1063.39 | 2 | 6 |
6 | 8 | -0.16 | 190 | 13.86 | 358 | 943 | 3.67 / 1064.33 | 2 | 15 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 29 | 13.84 | 497 | 199 | 0.20 / 1057.15 | 2 | 4 |
2 | 12 | 1129.36 | 60 | 10.58 | 1957 | 1242 | 1.44 / 1058.39 | 2 | 2 |
3 | 7 | 1131.32 | 21 | 11.66 | 1974 | 483 | 1.93 / 1058.88 | 2 | 3 |
4 | 13 | 917.08 | 30 | 13.14 | 1665 | 656 | 2.58 / 1059.53 | 2 | 5 |
5 | 13 | 86.16 | 30 | 13.93 | 468 | 196 | 2.78 / 1059.73 | 2 | 7 |
6 | 8 | -0.16 | 190 | 13.88 | 355 | 936 | 3.71 / 1060.66 | 2 | 19 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 28 | 13.85 | 500 | 194 | 0.19 / 1052.10 | 2 | 4 |
2 | 12 | 1122.84 | 5 | 12.55 | 2001 | 126 | 0.32 / 1052.23 | 2 | 2 |
3 | 12 | 1990.04 | 60 | 10.87 | 3193 | 2082 | 2.40 / 1054.31 | 2 | 2 |
4 | 7 | 1980.36 | 20 | 10.86 | 3182 | 691 | 3.09 / 1055.00 | 2 | 2 |
5 | 13 | 1009.52 | 30 | 13.09 | 1774 | 697 | 3.79 / 1055.70 | 2 | 5 |
6 | 13 | 279.60 | 30 | 13.72 | 741 | 305 | 4.09 / 1056.00 | 2 | 8 |
7 | 8 | 0.20 | 190 | 13.87 | 361 | 951 | 5.05 / 1056.95 | 2 | 16 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 29 | 13.82 | 501 | 201 | 0.20 / 1048.36 | 2 | 4 |
2 | 3 | 1023.64 | 1 | 12.83 | 1879 | 24 | 0.22 / 1048.38 | 2 | 2 |
3 | 12 | 1122.44 | 60 | 10.38 | 1949 | 1214 | 1.44 / 1049.60 | 2 | 2 |
4 | 7 | 1123.84 | 21 | 11.57 | 1970 | 479 | 1.92 / 1050.08 | 2 | 3 |
5 | 13 | 909.00 | 30 | 13.11 | 1638 | 644 | 2.56 / 1050.72 | 2 | 5 |
6 | 13 | 157.16 | 30 | 13.82 | 574 | 238 | 2.80 / 1050.96 | 2 | 7 |
7 | 8 | 0.28 | 190 | 13.84 | 360 | 947 | 3.75 / 1051.91 | 2 | 16 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 28 | 13.83 | 496 | 192 | 0.19 / 1044.64 | 2 | 4 |
2 | 12 | 1132.52 | 60 | 10.40 | 1965 | 1226 | 1.42 / 1045.87 | 2 | 2 |
3 | 7 | 1134.40 | 21 | 11.61 | 1977 | 482 | 1.90 / 1046.35 | 2 | 3 |
4 | 13 | 922.40 | 30 | 13.12 | 1667 | 656 | 2.56 / 1047.01 | 2 | 5 |
5 | 13 | 83.76 | 30 | 13.93 | 473 | 198 | 2.75 / 1047.21 | 2 | 7 |
6 | 8 | -0.12 | 190 | 13.86 | 362 | 953 | 3.71 / 1048.16 | 2 | 12 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 28 | 13.81 | 488 | 189 | 0.19 / 1040.93 | 2 | 4 |
2 | 3 | 1023.16 | 1 | 12.70 | 1876 | 24 | 0.21 / 1040.95 | 2 | 2 |
3 | 12 | 1131.52 | 60 | 10.64 | 1963 | 1253 | 1.47 / 1042.20 | 2 | 2 |
4 | 7 | 1133.24 | 20 | 11.69 | 1980 | 463 | 1.93 / 1042.67 | 2 | 3 |
5 | 13 | 917.84 | 30 | 13.14 | 1662 | 655 | 2.58 / 1043.32 | 2 | 5 |
6 | 13 | 84.44 | 30 | 13.93 | 465 | 194 | 2.78 / 1043.52 | 2 | 7 |
7 | 8 | 0.08 | 190 | 13.88 | 355 | 936 | 3.71 / 1044.45 | 2 | 19 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 28 | 13.84 | 496 | 192 | 0.19 / 1035.80 | 2 | 4 |
2 | 12 | 1118.20 | 5 | 12.57 | 2002 | 126 | 0.32 / 1035.92 | 2 | 2 |
3 | 12 | 1987.76 | 60 | 10.91 | 3185 | 2085 | 2.40 / 1038.01 | 2 | 2 |
4 | 7 | 1978.44 | 21 | 10.82 | 3177 | 722 | 3.12 / 1038.73 | 2 | 2 |
5 | 13 | 1215.76 | 30 | 12.90 | 2073 | 802 | 3.93 / 1039.53 | 2 | 4 |
6 | 13 | 227.32 | 30 | 13.77 | 667 | 276 | 4.20 / 1039.81 | 2 | 8 |
7 | 8 | 0.20 | 190 | 13.88 | 353 | 931 | 5.13 / 1040.74 | 2 | 13 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 27 | 13.84 | 503 | 188 | 0.19 / 1032.08 | 2 | 4 |
2 | 3 | 1045.96 | 1 | 13.02 | 1915 | 25 | 0.21 / 1032.11 | 2 | 2 |
3 | 12 | 1140.80 | 60 | 10.37 | 1978 | 1231 | 1.44 / 1033.34 | 2 | 2 |
4 | 7 | 1142.20 | 20 | 11.59 | 1998 | 463 | 1.91 / 1033.80 | 2 | 3 |
5 | 13 | 929.32 | 30 | 13.09 | 1660 | 652 | 2.56 / 1034.45 | 2 | 5 |
6 | 13 | 103.16 | 30 | 13.89 | 493 | 205 | 2.76 / 1034.66 | 2 | 7 |
7 | 8 | 0.48 | 190 | 13.84 | 360 | 947 | 3.71 / 1035.60 | 2 | 17 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 28 | 13.82 | 522 | 202 | 0.20 / 1028.41 | 2 | 5 |
2 | 12 | 1123.72 | 60 | 10.42 | 1954 | 1222 | 1.42 / 1029.63 | 2 | 2 |
3 | 7 | 1125.04 | 21 | 11.61 | 1973 | 481 | 1.90 / 1030.11 | 2 | 3 |
4 | 13 | 916.00 | 30 | 13.09 | 1678 | 659 | 2.56 / 1030.77 | 2 | 6 |
5 | 13 | 36.84 | 30 | 13.97 | 416 | 174 | 2.74 / 1030.94 | 2 | 7 |
6 | 8 | 0.04 | 190 | 13.84 | 362 | 952 | 3.69 / 1031.89 | 2 | 14 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 28 | 13.83 | 494 | 191 | 0.19 / 1024.82 | 2 | 4 |
2 | 12 | 1128.72 | 48 | 10.73 | 1963 | 1011 | 1.20 / 1025.83 | 2 | 2 |
3 | 7 | 1131.24 | 20 | 11.89 | 1992 | 474 | 1.68 / 1026.30 | 2 | 3 |
4 | 13 | 949.40 | 30 | 13.10 | 1688 | 663 | 2.34 / 1026.97 | 2 | 5 |
5 | 13 | 254.16 | 30 | 13.73 | 710 | 292 | 2.63 / 1027.26 | 2 | 8 |
6 | 8 | -0.20 | 190 | 13.87 | 359 | 946 | 3.58 / 1028.20 | 2 | 18 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 27 | 13.86 | 498 | 186 | 0.19 / 1019.91 | 2 | 4 |
2 | 3 | 1024.12 | 1 | 12.77 | 1885 | 24 | 0.21 / 1019.94 | 2 | 2 |
3 | 12 | 1116.08 | 5 | 12.63 | 1998 | 126 | 0.34 / 1020.06 | 2 | 2 |
4 | 12 | 1986.52 | 48 | 11.13 | 3182 | 1700 | 2.04 / 1021.76 | 2 | 2 |
5 | 7 | 1978.64 | 21 | 10.88 | 3185 | 728 | 2.76 / 1022.49 | 2 | 2 |
6 | 13 | 1268.04 | 30 | 12.83 | 2179 | 839 | 3.60 / 1023.33 | 2 | 4 |
7 | 13 | 336.88 | 30 | 13.65 | 825 | 338 | 3.94 / 1023.67 | 2 | 8 |
8 | 8 | 0.32 | 190 | 13.87 | 363 | 957 | 4.90 / 1024.63 | 2 | 15 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 27 | 13.84 | 503 | 188 | 0.19 / 1016.41 | 2 | 4 |
2 | 12 | 1096.16 | 48 | 10.45 | 1914 | 960 | 1.15 / 1017.37 | 2 | 2 |
3 | 7 | 1099.44 | 21 | 11.81 | 1944 | 482 | 1.63 / 1017.85 | 2 | 3 |
4 | 13 | 928.48 | 30 | 13.03 | 1698 | 664 | 2.29 / 1018.52 | 2 | 5 |
5 | 13 | 225.52 | 30 | 13.74 | 668 | 275 | 2.57 / 1018.79 | 2 | 7 |
6 | 8 | 0.20 | 190 | 13.84 | 356 | 936 | 3.51 / 1019.73 | 2 | 15 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 28 | 13.85 | 511 | 198 | 0.20 / 1012.87 | 2 | 4 |
2 | 12 | 1121.08 | 48 | 10.42 | 1953 | 977 | 1.17 / 1013.85 | 2 | 2 |
3 | 7 | 1124.56 | 21 | 11.82 | 1976 | 490 | 1.67 / 1014.34 | 2 | 3 |
4 | 13 | 944.04 | 30 | 13.07 | 1691 | 663 | 2.33 / 1015.00 | 2 | 4 |
5 | 13 | 246.80 | 30 | 13.72 | 705 | 290 | 2.62 / 1015.29 | 2 | 9 |
6 | 8 | -0.12 | 190 | 13.88 | 354 | 934 | 3.55 / 1016.22 | 2 | 17 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 28 | 13.84 | 516 | 200 | 0.20 / 1009.30 | 2 | 4 |
2 | 12 | 1116.04 | 48 | 10.73 | 1945 | 1002 | 1.20 / 1010.30 | 2 | 2 |
3 | 7 | 1118.84 | 21 | 11.90 | 1967 | 492 | 1.69 / 1010.79 | 2 | 3 |
4 | 13 | 930.36 | 30 | 13.09 | 1699 | 667 | 2.36 / 1011.46 | 2 | 5 |
5 | 13 | 218.32 | 30 | 13.77 | 668 | 276 | 2.64 / 1011.73 | 2 | 9 |
6 | 8 | 0.52 | 190 | 13.89 | 355 | 937 | 3.57 / 1012.67 | 2 | 15 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 27 | 13.85 | 505 | 189 | 0.19 / 1004.33 | 2 | 4 |
2 | 12 | 1097.60 | 5 | 12.59 | 1961 | 123 | 0.31 / 1004.45 | 2 | 2 |
3 | 12 | 1994.60 | 48 | 11.03 | 3186 | 1687 | 2.00 / 1006.14 | 2 | 2 |
4 | 7 | 1986.80 | 20 | 10.96 | 3194 | 700 | 2.70 / 1006.84 | 2 | 2 |
5 | 13 | 1293.84 | 30 | 12.82 | 2206 | 848 | 3.55 / 1007.69 | 2 | 4 |
6 | 13 | 560.44 | 30 | 13.46 | 1146 | 463 | 4.01 / 1008.15 | 2 | 7 |
7 | 8 | 0.16 | 190 | 13.91 | 359 | 949 | 4.96 / 1009.10 | 2 | 18 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 27 | 13.87 | 504 | 189 | 0.19 / 1000.63 | 2 | 4 |
2 | 12 | 1125.64 | 48 | 10.40 | 1955 | 976 | 1.16 / 1001.60 | 2 | 2 |
3 | 7 | 1129.16 | 21 | 11.78 | 1979 | 490 | 1.65 / 1002.09 | 2 | 3 |
4 | 13 | 946.28 | 30 | 13.04 | 1691 | 662 | 2.32 / 1002.76 | 2 | 5 |
5 | 13 | 254.80 | 30 | 13.72 | 712 | 293 | 2.61 / 1003.05 | 2 | 8 |
6 | 13 | 48.12 | 30 | 13.97 | 417 | 175 | 2.78 / 1003.22 | 2 | 9 |
7 | 8 | -0.24 | 190 | 13.91 | 346 | 914 | 3.70 / 1004.14 | 2 | 30 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 28 | 13.87 | 498 | 193 | 0.19 / 997.09 | 2 | 4 |
2 | 12 | 1112.60 | 48 | 10.48 | 1941 | 976 | 1.17 / 998.07 | 2 | 2 |
3 | 7 | 1117.72 | 21 | 11.84 | 1965 | 489 | 1.66 / 998.56 | 2 | 3 |
4 | 13 | 943.20 | 30 | 13.05 | 1701 | 666 | 2.32 / 999.23 | 2 | 5 |
5 | 13 | 254.88 | 30 | 13.73 | 710 | 292 | 2.62 / 999.52 | 2 | 9 |
6 | 8 | 0.40 | 190 | 13.91 | 349 | 922 | 3.54 / 1000.44 | 2 | 18 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 28 | 13.84 | 524 | 203 | 0.20 / 993.54 | 2 | 4 |
2 | 12 | 1102.76 | 48 | 10.81 | 1925 | 999 | 1.20 / 994.54 | 2 | 2 |
3 | 7 | 1106.36 | 21 | 11.91 | 1947 | 487 | 1.69 / 995.03 | 2 | 3 |
4 | 13 | 924.32 | 30 | 13.09 | 1684 | 661 | 2.35 / 995.69 | 2 | 5 |
5 | 13 | 215.16 | 30 | 13.78 | 663 | 274 | 2.62 / 995.97 | 2 | 9 |
6 | 8 | 0.20 | 190 | 13.91 | 354 | 936 | 3.56 / 996.90 | 2 | 17 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 27 | 13.85 | 515 | 193 | 0.19 / 988.65 | 2 | 4 |
2 | 12 | 1101.84 | 5 | 12.62 | 1967 | 124 | 0.32 / 988.77 | 2 | 2 |
3 | 12 | 1993.52 | 48 | 11.10 | 3190 | 1700 | 2.02 / 990.47 | 2 | 2 |
4 | 7 | 1985.44 | 21 | 10.93 | 3195 | 733 | 2.75 / 991.20 | 2 | 2 |
5 | 13 | 1276.56 | 30 | 12.82 | 2190 | 842 | 3.59 / 992.05 | 2 | 4 |
6 | 13 | 333.24 | 30 | 13.66 | 837 | 343 | 3.93 / 992.39 | 2 | 9 |
7 | 8 | 0.16 | 190 | 13.91 | 360 | 951 | 4.89 / 993.34 | 2 | 17 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 27 | 13.86 | 514 | 192 | 0.19 / 985.10 | 2 | 4 |
2 | 12 | 1135.72 | 48 | 10.39 | 1973 | 984 | 1.18 / 986.08 | 2 | 2 |
3 | 7 | 1139.20 | 20 | 11.80 | 1996 | 471 | 1.65 / 986.55 | 2 | 3 |
4 | 13 | 961.40 | 30 | 13.00 | 1743 | 680 | 2.33 / 987.23 | 2 | 5 |
5 | 13 | 279.92 | 30 | 13.68 | 752 | 309 | 2.64 / 987.54 | 2 | 9 |
6 | 8 | -0.24 | 190 | 13.89 | 347 | 916 | 3.55 / 988.45 | 2 | 19 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 28 | 13.87 | 515 | 200 | 0.20 / 981.58 | 2 | 4 |
2 | 12 | 1092.92 | 48 | 10.55 | 1912 | 968 | 1.17 / 982.55 | 2 | 2 |
3 | 7 | 1095.40 | 21 | 11.87 | 1936 | 483 | 1.65 / 983.04 | 2 | 3 |
4 | 13 | 914.84 | 30 | 13.08 | 1658 | 651 | 2.30 / 983.69 | 2 | 5 |
5 | 13 | 230.44 | 30 | 13.75 | 681 | 281 | 2.58 / 983.97 | 2 | 8 |
6 | 8 | 0.36 | 190 | 13.88 | 355 | 936 | 3.52 / 984.90 | 2 | 15 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 28 | 13.87 | 518 | 201 | 0.20 / 978.02 | 2 | 4 |
2 | 12 | 1107.04 | 48 | 10.83 | 1932 | 1004 | 1.21 / 979.02 | 2 | 2 |
3 | 7 | 1110.96 | 21 | 11.92 | 1960 | 491 | 1.70 / 979.51 | 2 | 3 |
4 | 13 | 920.80 | 30 | 13.09 | 1693 | 665 | 2.36 / 980.18 | 2 | 5 |
5 | 13 | 212.08 | 30 | 13.78 | 661 | 273 | 2.63 / 980.45 | 2 | 9 |
6 | 8 | -0.16 | 190 | 13.92 | 353 | 934 | 3.57 / 981.38 | 2 | 19 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 27 | 13.88 | 506 | 190 | 0.19 / 973.12 | 2 | 4 |
2 | 12 | 1107.16 | 5 | 12.56 | 1975 | 124 | 0.31 / 973.25 | 2 | 2 |
3 | 12 | 1997.92 | 48 | 11.02 | 3194 | 1689 | 2.00 / 974.94 | 2 | 2 |
4 | 7 | 1990.80 | 21 | 10.92 | 3190 | 732 | 2.73 / 975.67 | 2 | 2 |
5 | 13 | 1289.72 | 30 | 12.80 | 2207 | 847 | 3.58 / 976.51 | 2 | 4 |
6 | 13 | 364.36 | 30 | 13.63 | 886 | 362 | 3.94 / 976.88 | 2 | 8 |
7 | 8 | 0.04 | 190 | 13.94 | 355 | 940 | 4.88 / 977.82 | 2 | 17 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 27 | 13.85 | 511 | 191 | 0.19 / 969.42 | 2 | 4 |
2 | 12 | 1128.44 | 48 | 10.41 | 1955 | 977 | 1.17 / 970.40 | 2 | 2 |
3 | 7 | 1132.28 | 21 | 11.80 | 1981 | 491 | 1.66 / 970.89 | 2 | 3 |
4 | 13 | 959.08 | 30 | 13.00 | 1731 | 675 | 2.33 / 971.56 | 2 | 4 |
5 | 13 | 266.28 | 30 | 13.70 | 733 | 301 | 2.64 / 971.87 | 2 | 8 |
6 | 13 | 2.32 | 30 | 14.05 | 356 | 150 | 2.79 / 972.02 | 2 | 11 |
7 | 8 | 0.24 | 190 | 13.90 | 347 | 916 | 3.70 / 972.93 | 2 | 20 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 28 | 13.87 | 508 | 197 | 0.20 / 965.89 | 2 | 4 |
2 | 12 | 1103.00 | 48 | 10.57 | 1925 | 977 | 1.17 / 966.87 | 2 | 2 |
3 | 7 | 1107.28 | 21 | 11.87 | 1949 | 486 | 1.66 / 967.36 | 2 | 3 |
4 | 13 | 935.80 | 30 | 13.06 | 1694 | 664 | 2.32 / 968.02 | 2 | 5 |
5 | 13 | 241.92 | 30 | 13.74 | 692 | 285 | 2.61 / 968.30 | 2 | 8 |
6 | 8 | -0.08 | 190 | 13.92 | 350 | 926 | 3.53 / 969.23 | 2 | 17 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 28 | 13.87 | 512 | 199 | 0.20 / 962.30 | 2 | 4 |
2 | 12 | 1119.72 | 48 | 10.87 | 1947 | 1016 | 1.21 / 963.32 | 2 | 2 |
3 | 7 | 1124.12 | 21 | 11.90 | 1976 | 494 | 1.71 / 963.81 | 2 | 3 |
4 | 13 | 938.32 | 30 | 13.08 | 1708 | 670 | 2.38 / 964.48 | 2 | 5 |
5 | 13 | 227.16 | 30 | 13.76 | 677 | 279 | 2.66 / 964.76 | 2 | 9 |
6 | 8 | 0.40 | 190 | 13.93 | 353 | 934 | 3.59 / 965.70 | 2 | 16 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 27 | 13.90 | 495 | 186 | 0.19 / 957.41 | 2 | 4 |
2 | 12 | 1094.12 | 5 | 12.54 | 1958 | 123 | 0.31 / 957.53 | 2 | 2 |
3 | 12 | 2000.84 | 48 | 11.06 | 3194 | 1696 | 2.00 / 959.23 | 2 | 2 |
4 | 7 | 1993.28 | 21 | 10.92 | 3201 | 734 | 2.74 / 959.96 | 2 | 2 |
5 | 13 | 1285.36 | 30 | 12.82 | 2192 | 843 | 3.58 / 960.81 | 2 | 4 |
6 | 13 | 360.24 | 30 | 13.64 | 877 | 359 | 3.94 / 961.17 | 2 | 8 |
7 | 8 | 0.04 | 190 | 13.95 | 354 | 938 | 4.88 / 962.10 | 2 | 20 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 27 | 13.89 | 504 | 189 | 0.19 / 953.89 | 2 | 4 |
2 | 12 | 1118.96 | 48 | 10.47 | 1944 | 977 | 1.17 / 954.86 | 2 | 2 |
3 | 7 | 1123.08 | 21 | 11.83 | 1968 | 489 | 1.65 / 955.35 | 2 | 3 |
4 | 13 | 945.80 | 30 | 13.02 | 1709 | 668 | 2.32 / 956.02 | 2 | 4 |
5 | 13 | 254.52 | 30 | 13.74 | 710 | 293 | 2.62 / 956.31 | 2 | 8 |
6 | 8 | 0.04 | 190 | 13.93 | 345 | 913 | 3.53 / 957.23 | 2 | 17 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 28 | 13.90 | 507 | 197 | 0.20 / 950.34 | 2 | 4 |
2 | 12 | 1124.28 | 48 | 10.57 | 1953 | 991 | 1.19 / 951.33 | 2 | 2 |
3 | 7 | 1128.36 | 21 | 11.86 | 1977 | 492 | 1.68 / 951.82 | 2 | 3 |
4 | 13 | 951.88 | 30 | 13.04 | 1714 | 671 | 2.35 / 952.49 | 2 | 4 |
5 | 13 | 248.12 | 30 | 13.75 | 702 | 290 | 2.64 / 952.78 | 2 | 8 |
6 | 8 | 0.20 | 190 | 13.94 | 346 | 916 | 3.56 / 953.70 | 2 | 18 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 27 | 13.86 | 513 | 192 | 0.19 / 946.73 | 2 | 4 |
2 | 12 | 1127.76 | 48 | 10.89 | 1959 | 1024 | 1.22 / 947.76 | 2 | 2 |
3 | 7 | 1130.72 | 21 | 11.92 | 1980 | 496 | 1.71 / 948.25 | 2 | 3 |
4 | 13 | 948.92 | 30 | 13.07 | 1724 | 676 | 2.39 / 948.93 | 2 | 5 |
5 | 13 | 235.44 | 30 | 13.77 | 688 | 284 | 2.67 / 949.21 | 2 | 9 |
6 | 8 | -0.12 | 190 | 13.95 | 349 | 925 | 3.60 / 950.14 | 2 | 17 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 27 | 13.90 | 504 | 189 | 0.19 / 941.91 | 2 | 4 |
2 | 12 | 1123.96 | 5 | 12.60 | 2005 | 126 | 0.32 / 942.04 | 2 | 2 |
3 | 12 | 2004.04 | 48 | 11.14 | 3210 | 1716 | 2.03 / 943.76 | 2 | 2 |
4 | 7 | 1997.04 | 21 | 10.98 | 3197 | 737 | 2.77 / 944.49 | 2 | 2 |
5 | 13 | 1103.88 | 30 | 12.98 | 1922 | 748 | 3.52 / 945.24 | 2 | 4 |
6 | 13 | 412.44 | 30 | 13.59 | 942 | 384 | 3.90 / 945.63 | 2 | 9 |
7 | 8 | 0.08 | 190 | 13.96 | 346 | 918 | 4.82 / 946.54 | 2 | 19 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 28 | 13.89 | 501 | 195 | 0.19 / 938.31 | 2 | 4 |
2 | 3 | 972.00 | -1 | 13.89 | 501 | 0 | 0.00 / 938.31 | 2 | 4 |
3 | 12 | 1151.40 | 48 | 10.50 | 1989 | 1002 | 1.20 / 939.32 | 2 | 2 |
4 | 7 | 1155.76 | 21 | 11.80 | 2016 | 500 | 1.70 / 939.81 | 2 | 3 |
5 | 13 | 983.08 | 30 | 13.00 | 1757 | 685 | 2.38 / 940.50 | 2 | 4 |
6 | 13 | 288.76 | 30 | 13.69 | 767 | 315 | 2.70 / 940.82 | 2 | 9 |
7 | 8 | 0.32 | 190 | 13.94 | 343 | 908 | 3.61 / 941.72 | 2 | 17 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 27 | 13.88 | 512 | 192 | 0.19 / 934.77 | 2 | 4 |
2 | 12 | 1111.92 | 48 | 10.68 | 1935 | 992 | 1.18 / 935.76 | 2 | 2 |
3 | 7 | 1115.80 | 21 | 11.88 | 1959 | 489 | 1.67 / 936.25 | 2 | 3 |
4 | 13 | 940.00 | 30 | 13.06 | 1693 | 663 | 2.34 / 936.91 | 2 | 5 |
5 | 13 | 246.12 | 30 | 13.73 | 703 | 290 | 2.63 / 937.20 | 2 | 9 |
6 | 8 | 0.12 | 190 | 13.92 | 347 | 918 | 3.54 / 938.12 | 2 | 16 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 27 | 13.91 | 504 | 189 | 0.19 / 931.17 | 2 | 4 |
2 | 12 | 1123.60 | 48 | 10.96 | 1957 | 1030 | 1.22 / 932.20 | 2 | 2 |
3 | 7 | 1127.52 | 21 | 11.92 | 1978 | 495 | 1.71 / 932.70 | 2 | 3 |
4 | 13 | 941.60 | 30 | 13.09 | 1703 | 669 | 2.38 / 933.36 | 2 | 5 |
5 | 13 | 232.08 | 30 | 13.76 | 683 | 282 | 2.66 / 933.65 | 2 | 9 |
6 | 8 | -0.12 | 190 | 13.93 | 351 | 929 | 3.59 / 934.57 | 2 | 16 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 27 | 13.89 | 516 | 194 | 0.19 / 926.15 | 2 | 4 |
2 | 12 | 1120.00 | 5 | 12.65 | 1998 | 126 | 0.32 / 926.27 | 2 | 2 |
3 | 12 | 1997.20 | 48 | 11.21 | 3210 | 1727 | 2.05 / 928.00 | 2 | 2 |
4 | 7 | 1989.72 | 21 | 11.02 | 3184 | 737 | 2.78 / 928.74 | 2 | 2 |
5 | 13 | 1285.68 | 30 | 12.84 | 2184 | 841 | 3.63 / 929.58 | 2 | 4 |
6 | 13 | 550.44 | 30 | 13.47 | 1130 | 457 | 4.08 / 930.03 | 2 | 8 |
7 | 8 | 0.16 | 190 | 13.93 | 358 | 948 | 5.03 / 930.98 | 2 | 17 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 25 | 13.92 | 504 | 175 | 0.18 / 922.51 | 2 | 4 |
2 | 10 | 1009.24 | 3 | 13.29 | 1845 | 74 | 0.25 / 922.58 | 2 | 4 |
3 | 12 | 1120.72 | 48 | 10.56 | 1952 | 989 | 1.24 / 923.57 | 2 | 2 |
4 | 7 | 1124.40 | 21 | 11.82 | 1976 | 490 | 1.73 / 924.06 | 2 | 3 |
5 | 13 | 939.88 | 30 | 13.04 | 1707 | 668 | 2.40 / 924.73 | 2 | 5 |
6 | 13 | 263.04 | 30 | 13.71 | 728 | 299 | 2.70 / 925.03 | 2 | 9 |
7 | 8 | -0.04 | 190 | 13.91 | 348 | 920 | 3.62 / 925.95 | 2 | 17 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 27 | 13.92 | 506 | 190 | 0.19 / 918.94 | 2 | 4 |
2 | 12 | 1116.92 | 48 | 10.73 | 1945 | 1002 | 1.19 / 919.94 | 2 | 2 |
3 | 7 | 1120.72 | 21 | 11.88 | 1967 | 491 | 1.68 / 920.43 | 2 | 3 |
4 | 13 | 949.32 | 30 | 13.05 | 1721 | 674 | 2.36 / 921.11 | 2 | 5 |
5 | 13 | 252.52 | 30 | 13.73 | 714 | 294 | 2.65 / 921.40 | 2 | 9 |
6 | 8 | 0.28 | 190 | 13.92 | 353 | 934 | 3.58 / 922.34 | 2 | 18 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 27 | 13.90 | 525 | 197 | 0.20 / 915.36 | 2 | 5 |
2 | 12 | 1109.36 | 48 | 11.12 | 1940 | 1035 | 1.23 / 916.39 | 2 | 2 |
3 | 7 | 1112.28 | 21 | 11.96 | 1958 | 492 | 1.72 / 916.88 | 2 | 3 |
4 | 13 | 925.28 | 30 | 13.10 | 1696 | 667 | 2.39 / 917.55 | 2 | 6 |
5 | 13 | 212.24 | 30 | 13.79 | 658 | 272 | 2.66 / 917.82 | 2 | 9 |
6 | 8 | 0.08 | 190 | 13.95 | 351 | 930 | 3.59 / 918.75 | 2 | 25 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 25 | 13.93 | 508 | 177 | 0.18 / 910.21 | 2 | 5 |
2 | 3 | 1065.16 | 2 | 13.23 | 1942 | 51 | 0.23 / 910.26 | 2 | 3 |
3 | 3 | 1018.60 | 1 | 12.63 | 1876 | 24 | 0.25 / 910.28 | 2 | 2 |
4 | 12 | 1126.28 | 5 | 12.86 | 2019 | 130 | 0.38 / 910.41 | 2 | 2 |
5 | 12 | 1991.40 | 48 | 11.59 | 3196 | 1778 | 2.16 / 912.19 | 2 | 2 |
6 | 7 | 1983.92 | 21 | 11.15 | 3177 | 744 | 2.90 / 912.93 | 2 | 2 |
7 | 13 | 1254.92 | 30 | 12.92 | 2130 | 826 | 3.73 / 913.76 | 2 | 4 |
8 | 13 | 514.08 | 30 | 13.54 | 1078 | 438 | 4.17 / 914.20 | 2 | 8 |
9 | 8 | 0.16 | 190 | 13.96 | 362 | 960 | 5.13 / 915.16 | 2 | 15 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 27 | 13.92 | 504 | 189 | 0.19 / 905.24 | 2 | 4 |
2 | 12 | 1105.68 | 6 | 10.97 | 1942 | 128 | 0.32 / 905.37 | 2 | 2 |
3 | 12 | 2000.52 | 48 | 9.60 | 3153 | 1453 | 1.77 / 906.82 | 2 | 2 |
4 | 7 | 1994.76 | 21 | 10.83 | 3193 | 726 | 2.50 / 907.55 | 2 | 2 |
5 | 13 | 1533.72 | 30 | 12.61 | 2539 | 961 | 3.46 / 908.51 | 2 | 3 |
6 | 13 | 793.80 | 30 | 13.26 | 1480 | 589 | 4.05 / 909.10 | 2 | 7 |
7 | 8 | 0.44 | 190 | 13.98 | 352 | 935 | 4.98 / 910.03 | 2 | 16 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 26 | 13.93 | 511 | 185 | 0.19 / 900.15 | 2 | 4 |
2 | 3 | 1030.84 | 1 | 13.06 | 1892 | 25 | 0.21 / 900.17 | 2 | 2 |
3 | 12 | 1127.12 | 6 | 11.21 | 1994 | 134 | 0.34 / 900.31 | 2 | 2 |
4 | 12 | 2003.32 | 48 | 9.62 | 3155 | 1457 | 1.80 / 901.77 | 2 | 2 |
5 | 7 | 1997.36 | 21 | 10.81 | 3184 | 723 | 2.52 / 902.49 | 2 | 2 |
6 | 13 | 1534.84 | 30 | 12.62 | 2555 | 967 | 3.49 / 903.46 | 2 | 3 |
7 | 13 | 605.92 | 30 | 13.43 | 1213 | 489 | 3.98 / 903.94 | 2 | 7 |
8 | 13 | 43.00 | 30 | 14.04 | 414 | 174 | 4.15 / 904.12 | 2 | 7 |
9 | 8 | -0.12 | 190 | 13.97 | 351 | 932 | 5.09 / 905.05 | 2 | 17 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 28 | 13.91 | 516 | 201 | 0.20 / 895.07 | 2 | 4 |
2 | 3 | 956.92 | -1 | 13.91 | 516 | 0 | 0.00 / 895.07 | 2 | 4 |
3 | 12 | 1125.00 | 6 | 11.11 | 1972 | 131 | 0.33 / 895.21 | 2 | 2 |
4 | 12 | 2002.40 | 48 | 9.65 | 3164 | 1466 | 1.80 / 896.67 | 2 | 2 |
5 | 7 | 1996.64 | 21 | 10.80 | 3189 | 723 | 2.52 / 897.39 | 2 | 2 |
6 | 13 | 1552.68 | 30 | 12.59 | 2584 | 976 | 3.50 / 898.37 | 2 | 3 |
7 | 13 | 614.20 | 30 | 13.43 | 1220 | 492 | 3.99 / 898.86 | 2 | 7 |
8 | 13 | 2.32 | 30 | 14.10 | 368 | 156 | 4.14 / 899.02 | 2 | 7 |
9 | 8 | 0.48 | 190 | 13.93 | 358 | 948 | 5.09 / 899.96 | 2 | 20 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 28 | 13.90 | 519 | 202 | 0.20 / 889.99 | 2 | 4 |
2 | 12 | 1125.24 | 6 | 11.04 | 1972 | 131 | 0.33 / 890.12 | 2 | 2 |
3 | 12 | 2002.84 | 48 | 9.66 | 3162 | 1466 | 1.80 / 891.58 | 2 | 2 |
4 | 7 | 1996.88 | 21 | 10.85 | 3182 | 725 | 2.52 / 892.31 | 2 | 2 |
5 | 13 | 1533.60 | 30 | 12.62 | 2549 | 965 | 3.49 / 893.27 | 2 | 3 |
6 | 13 | 610.76 | 30 | 13.42 | 1236 | 498 | 3.99 / 893.77 | 2 | 8 |
7 | 13 | 15.92 | 30 | 14.09 | 383 | 162 | 4.15 / 893.93 | 2 | 9 |
8 | 8 | -0.04 | 190 | 13.95 | 355 | 941 | 5.09 / 894.87 | 2 | 20 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 27 | 13.94 | 514 | 193 | 0.19 / 884.83 | 2 | 5 |
2 | 3 | 1024.84 | 1 | 13.05 | 1883 | 25 | 0.22 / 884.85 | 2 | 2 |
3 | 12 | 1142.00 | 6 | 11.37 | 1998 | 136 | 0.35 / 884.99 | 2 | 2 |
4 | 12 | 2002.12 | 48 | 9.79 | 3167 | 1488 | 1.84 / 886.48 | 2 | 2 |
5 | 7 | 1995.84 | 21 | 10.85 | 3181 | 725 | 2.57 / 887.20 | 2 | 2 |
6 | 13 | 1539.00 | 30 | 12.63 | 2549 | 966 | 3.53 / 888.17 | 2 | 3 |
7 | 13 | 614.24 | 30 | 13.43 | 1227 | 494 | 4.03 / 888.66 | 2 | 6 |
8 | 13 | 18.52 | 30 | 14.08 | 391 | 165 | 4.19 / 888.83 | 2 | 9 |
9 | 8 | 0.08 | 190 | 13.96 | 360 | 955 | 5.15 / 889.78 | 2 | 13 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 27 | 13.92 | 520 | 195 | 0.20 / 879.97 | 2 | 5 |
2 | 12 | 1141.92 | 6 | 11.12 | 1992 | 133 | 0.33 / 880.11 | 2 | 2 |
3 | 12 | 2004.68 | 48 | 9.69 | 3157 | 1468 | 1.80 / 881.57 | 2 | 2 |
4 | 7 | 1998.40 | 21 | 10.86 | 3194 | 728 | 2.53 / 882.30 | 2 | 2 |
5 | 13 | 1348.88 | 30 | 12.80 | 2257 | 867 | 3.39 / 883.17 | 2 | 4 |
6 | 13 | 644.16 | 30 | 13.38 | 1271 | 510 | 3.90 / 883.68 | 2 | 7 |
7 | 8 | -0.04 | 190 | 13.94 | 361 | 956 | 4.86 / 884.64 | 2 | 16 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 26 | 13.92 | 524 | 190 | 0.19 / 875.12 | 2 | 5 |
2 | 12 | 1133.56 | 6 | 11.38 | 1994 | 136 | 0.33 / 875.26 | 2 | 2 |
3 | 12 | 2005.16 | 48 | 9.71 | 3154 | 1470 | 1.80 / 876.73 | 2 | 2 |
4 | 7 | 1999.64 | 21 | 10.85 | 3199 | 729 | 2.52 / 877.46 | 2 | 2 |
5 | 13 | 1340.00 | 30 | 12.79 | 2261 | 868 | 3.39 / 878.33 | 2 | 4 |
6 | 13 | 637.16 | 30 | 13.40 | 1254 | 504 | 3.90 / 878.83 | 2 | 8 |
7 | 8 | 0.16 | 190 | 13.96 | 357 | 947 | 4.84 / 879.78 | 2 | 15 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 26 | 13.95 | 517 | 188 | 0.19 / 870.12 | 2 | 4 |
2 | 12 | 1104.76 | 6 | 11.05 | 1943 | 129 | 0.32 / 870.25 | 2 | 2 |
3 | 12 | 2003.76 | 48 | 9.65 | 3158 | 1463 | 1.78 / 871.71 | 2 | 2 |
4 | 7 | 1997.64 | 21 | 10.83 | 3195 | 727 | 2.51 / 872.44 | 2 | 2 |
5 | 13 | 1534.60 | 30 | 12.59 | 2558 | 966 | 3.47 / 873.41 | 2 | 3 |
6 | 13 | 765.96 | 30 | 13.29 | 1426 | 569 | 4.04 / 873.97 | 2 | 7 |
7 | 8 | -0.32 | 190 | 13.93 | 363 | 961 | 5.00 / 874.93 | 2 | 16 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 26 | 13.92 | 514 | 186 | 0.19 / 865.05 | 2 | 5 |
2 | 12 | 1118.08 | 6 | 11.10 | 1976 | 132 | 0.32 / 865.18 | 2 | 2 |
3 | 12 | 2000.08 | 48 | 9.66 | 3154 | 1462 | 1.78 / 866.64 | 2 | 2 |
4 | 7 | 1993.64 | 21 | 10.82 | 3185 | 724 | 2.50 / 867.37 | 2 | 2 |
5 | 13 | 1538.72 | 30 | 12.60 | 2562 | 968 | 3.47 / 868.33 | 2 | 3 |
6 | 13 | 585.72 | 30 | 13.43 | 1186 | 478 | 3.95 / 868.81 | 2 | 8 |
7 | 13 | 2.44 | 30 | 14.08 | 375 | 158 | 4.11 / 868.97 | 2 | 6 |
8 | 8 | 0.16 | 190 | 13.89 | 365 | 963 | 5.07 / 869.93 | 2 | 20 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 26 | 13.95 | 507 | 184 | 0.18 / 859.75 | 2 | 5 |
2 | 12 | 1111.12 | 7 | 11.17 | 1943 | 152 | 0.34 / 859.90 | 2 | 2 |
3 | 12 | 1985.12 | 48 | 9.75 | 3124 | 1462 | 1.80 / 861.37 | 2 | 2 |
4 | 7 | 1978.68 | 21 | 10.88 | 3166 | 723 | 2.52 / 862.09 | 2 | 2 |
5 | 13 | 1748.20 | 30 | 12.38 | 2861 | 1063 | 3.58 / 863.15 | 2 | 3 |
6 | 13 | 736.20 | 30 | 13.30 | 1403 | 560 | 4.14 / 863.71 | 2 | 8 |
7 | 13 | 97.52 | 30 | 13.96 | 490 | 205 | 4.35 / 863.92 | 2 | 7 |
8 | 8 | 0.48 | 190 | 13.96 | 356 | 944 | 5.29 / 864.86 | 2 | 13 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 26 | 13.96 | 509 | 185 | 0.18 / 854.77 | 2 | 5 |
2 | 12 | 1118.20 | 7 | 11.21 | 1951 | 153 | 0.34 / 854.92 | 2 | 2 |
3 | 12 | 1986.36 | 48 | 9.75 | 3133 | 1466 | 1.80 / 856.39 | 2 | 2 |
4 | 7 | 1979.68 | 21 | 10.89 | 3162 | 723 | 2.53 / 857.11 | 2 | 2 |
5 | 13 | 1513.68 | 30 | 12.63 | 2506 | 950 | 3.48 / 858.06 | 2 | 4 |
6 | 13 | 756.16 | 30 | 13.30 | 1416 | 565 | 4.04 / 858.63 | 2 | 7 |
7 | 8 | -0.36 | 190 | 13.95 | 355 | 941 | 4.98 / 859.57 | 2 | 16 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 26 | 13.94 | 501 | 182 | 0.18 / 849.57 | 2 | 4 |
2 | 12 | 1117.92 | 7 | 11.44 | 1964 | 157 | 0.34 / 849.73 | 2 | 2 |
3 | 12 | 1992.80 | 48 | 9.79 | 3139 | 1475 | 1.81 / 851.20 | 2 | 2 |
4 | 7 | 1986.16 | 21 | 10.89 | 3170 | 725 | 2.54 / 851.93 | 2 | 2 |
5 | 13 | 1535.16 | 30 | 12.62 | 2536 | 960 | 3.50 / 852.89 | 2 | 4 |
6 | 13 | 774.32 | 30 | 13.27 | 1442 | 574 | 4.07 / 853.46 | 2 | 7 |
7 | 13 | 59.08 | 30 | 14.02 | 436 | 183 | 4.26 / 853.64 | 2 | 7 |
8 | 8 | 0.20 | 190 | 13.94 | 356 | 943 | 5.20 / 854.59 | 2 | 19 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 27 | 13.98 | 501 | 189 | 0.19 / 844.26 | 2 | 4 |
2 | 3 | 972.04 | -1 | 13.98 | 501 | 0 | 0.00 / 844.26 | 2 | 4 |
3 | 12 | 1111.12 | 5 | 11.52 | 1973 | 114 | 0.30 / 844.37 | 2 | 2 |
4 | 12 | 2001.20 | 42 | 9.81 | 3141 | 1294 | 1.60 / 845.66 | 2 | 2 |
5 | 7 | 1997.04 | 21 | 10.94 | 3179 | 730 | 2.33 / 846.39 | 2 | 2 |
6 | 13 | 1766.88 | 30 | 12.37 | 2880 | 1069 | 3.40 / 847.46 | 2 | 3 |
7 | 13 | 1007.00 | 30 | 13.07 | 1795 | 704 | 4.10 / 848.17 | 2 | 6 |
8 | 13 | 225.56 | 30 | 13.82 | 673 | 279 | 4.38 / 848.45 | 2 | 10 |
9 | 8 | 0.36 | 190 | 13.96 | 355 | 942 | 5.32 / 849.39 | 2 | 17 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 27 | 13.99 | 503 | 190 | 0.19 / 838.84 | 2 | 4 |
2 | 12 | 1121.08 | 5 | 11.32 | 1976 | 112 | 0.30 / 838.95 | 2 | 2 |
3 | 12 | 2004.12 | 42 | 9.76 | 3126 | 1281 | 1.58 / 840.23 | 2 | 2 |
4 | 7 | 1999.80 | 20 | 11.02 | 3198 | 705 | 2.29 / 840.93 | 2 | 2 |
5 | 13 | 1758.52 | 30 | 12.40 | 2855 | 1062 | 3.35 / 842.00 | 2 | 3 |
6 | 13 | 1014.72 | 30 | 13.07 | 1791 | 702 | 4.05 / 842.70 | 2 | 5 |
7 | 13 | 236.60 | 30 | 13.83 | 684 | 284 | 4.34 / 842.98 | 2 | 9 |
8 | 13 | 46.52 | 30 | 14.08 | 416 | 176 | 4.51 / 843.16 | 2 | 11 |
9 | 8 | -0.04 | 190 | 14.01 | 341 | 908 | 5.42 / 844.07 | 2 | 19 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 27 | 14.00 | 504 | 191 | 0.19 / 833.60 | 2 | 4 |
2 | 12 | 1136.68 | 5 | 11.53 | 1992 | 115 | 0.31 / 833.72 | 2 | 2 |
3 | 12 | 2005.00 | 42 | 9.83 | 3152 | 1301 | 1.61 / 835.02 | 2 | 2 |
4 | 7 | 2001.12 | 21 | 10.94 | 3187 | 732 | 2.34 / 835.75 | 2 | 2 |
5 | 13 | 1771.88 | 30 | 12.35 | 2887 | 1070 | 3.41 / 836.82 | 2 | 3 |
6 | 13 | 1000.96 | 30 | 13.07 | 1781 | 698 | 4.11 / 837.52 | 2 | 6 |
7 | 13 | 110.28 | 30 | 13.98 | 503 | 211 | 4.32 / 837.73 | 2 | 9 |
8 | 8 | 0.12 | 190 | 14.01 | 344 | 916 | 5.23 / 838.65 | 2 | 20 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 27 | 13.98 | 512 | 193 | 0.19 / 828.38 | 2 | 4 |
2 | 12 | 1110.88 | 5 | 11.40 | 1973 | 112 | 0.31 / 828.49 | 2 | 2 |
3 | 12 | 2004.88 | 42 | 9.78 | 3128 | 1285 | 1.59 / 829.78 | 2 | 2 |
4 | 7 | 2000.88 | 21 | 10.95 | 3191 | 734 | 2.32 / 830.51 | 2 | 2 |
5 | 13 | 1760.84 | 30 | 12.37 | 2884 | 1070 | 3.39 / 831.58 | 2 | 3 |
6 | 13 | 997.84 | 30 | 13.07 | 1770 | 694 | 4.09 / 832.28 | 2 | 5 |
7 | 13 | 123.92 | 30 | 13.96 | 525 | 220 | 4.31 / 832.50 | 2 | 9 |
8 | 8 | -0.12 | 190 | 14.03 | 344 | 917 | 5.23 / 833.41 | 2 | 14 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 27 | 14.01 | 491 | 186 | 0.19 / 823.10 | 2 | 4 |
2 | 12 | 1112.92 | 5 | 11.55 | 1962 | 113 | 0.30 / 823.22 | 2 | 2 |
3 | 12 | 2000.40 | 42 | 9.84 | 3144 | 1299 | 1.60 / 824.51 | 2 | 2 |
4 | 7 | 1996.24 | 20 | 11.04 | 3182 | 703 | 2.30 / 825.22 | 2 | 2 |
5 | 13 | 1763.32 | 30 | 12.36 | 2887 | 1070 | 3.37 / 826.29 | 2 | 3 |
6 | 13 | 1009.20 | 30 | 13.08 | 1774 | 696 | 4.07 / 826.98 | 2 | 6 |
7 | 13 | 233.44 | 30 | 13.82 | 684 | 284 | 4.35 / 827.27 | 2 | 10 |
8 | 8 | 0.20 | 190 | 14.00 | 346 | 920 | 5.27 / 828.19 | 2 | 18 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 26 | 14.05 | 504 | 184 | 0.18 / 817.93 | 2 | 3 |
2 | 12 | 1105.12 | 5 | 11.38 | 1941 | 110 | 0.29 / 818.04 | 2 | 2 |
3 | 12 | 2001.68 | 42 | 9.88 | 3129 | 1298 | 1.59 / 819.33 | 2 | 2 |
4 | 7 | 1995.80 | 20 | 11.05 | 3187 | 704 | 2.30 / 820.04 | 2 | 2 |
5 | 13 | 1752.96 | 30 | 12.39 | 2874 | 1068 | 3.37 / 821.11 | 2 | 3 |
6 | 13 | 990.52 | 30 | 13.08 | 1777 | 697 | 4.06 / 821.80 | 2 | 6 |
7 | 13 | 100.04 | 30 | 13.99 | 487 | 204 | 4.27 / 822.01 | 2 | 9 |
8 | 8 | 0.00 | 190 | 14.01 | 341 | 908 | 5.17 / 822.92 | 2 | 25 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 26 | 14.07 | 499 | 183 | 0.18 / 812.62 | 2 | 3 |
2 | 12 | 1120.48 | 5 | 11.29 | 1975 | 111 | 0.29 / 812.73 | 2 | 2 |
3 | 12 | 2002.64 | 42 | 9.85 | 3132 | 1296 | 1.59 / 814.02 | 2 | 2 |
4 | 7 | 1998.76 | 21 | 10.98 | 3194 | 736 | 2.33 / 814.76 | 2 | 2 |
5 | 13 | 1761.52 | 30 | 12.37 | 2887 | 1071 | 3.40 / 815.83 | 2 | 3 |
6 | 13 | 1011.80 | 30 | 13.06 | 1799 | 705 | 4.10 / 816.54 | 2 | 5 |
7 | 13 | 228.80 | 30 | 13.84 | 680 | 282 | 4.38 / 816.82 | 2 | 9 |
8 | 8 | 0.20 | 190 | 14.04 | 346 | 923 | 5.31 / 817.74 | 2 | 18 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 27 | 14.06 | 494 | 188 | 0.19 / 807.38 | 2 | 3 |
2 | 3 | 964.40 | -1 | 14.06 | 494 | 0 | 0.00 / 807.38 | 2 | 3 |
3 | 12 | 1123.04 | 5 | 11.04 | 1971 | 109 | 0.30 / 807.49 | 2 | 2 |
4 | 12 | 2001.08 | 42 | 9.82 | 3122 | 1288 | 1.58 / 808.78 | 2 | 2 |
5 | 7 | 1996.56 | 21 | 11.00 | 3182 | 735 | 2.32 / 809.52 | 2 | 2 |
6 | 13 | 1769.92 | 30 | 12.38 | 2882 | 1070 | 3.39 / 810.59 | 2 | 3 |
7 | 13 | 1017.60 | 30 | 13.06 | 1804 | 707 | 4.10 / 811.29 | 2 | 5 |
8 | 13 | 129.48 | 30 | 13.97 | 538 | 225 | 4.32 / 811.52 | 2 | 8 |
9 | 8 | 0.32 | 190 | 14.04 | 343 | 915 | 5.24 / 812.43 | 2 | 18 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 27 | 14.07 | 497 | 189 | 0.19 / 802.11 | 2 | 3 |
2 | 12 | 1099.52 | 5 | 10.82 | 1920 | 104 | 0.29 / 802.22 | 2 | 2 |
3 | 12 | 2002.12 | 42 | 9.77 | 3122 | 1281 | 1.57 / 803.50 | 2 | 2 |
4 | 7 | 1998.28 | 21 | 10.99 | 3177 | 733 | 2.31 / 804.23 | 2 | 2 |
5 | 13 | 1767.64 | 30 | 12.37 | 2864 | 1063 | 3.37 / 805.29 | 2 | 3 |
6 | 13 | 1036.16 | 30 | 13.05 | 1816 | 711 | 4.08 / 806.01 | 2 | 5 |
7 | 13 | 258.16 | 30 | 13.83 | 713 | 296 | 4.38 / 806.30 | 2 | 9 |
8 | 8 | -0.04 | 190 | 14.07 | 335 | 896 | 5.27 / 807.20 | 2 | 26 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 27 | 14.08 | 482 | 183 | 0.18 / 796.82 | 2 | 3 |
2 | 12 | 1106.92 | 5 | 10.95 | 1942 | 106 | 0.29 / 796.93 | 2 | 2 |
3 | 12 | 2001.88 | 42 | 9.77 | 3119 | 1280 | 1.57 / 798.21 | 2 | 2 |
4 | 7 | 1998.16 | 21 | 10.97 | 3186 | 734 | 2.30 / 798.94 | 2 | 2 |
5 | 13 | 1770.04 | 30 | 12.35 | 2897 | 1073 | 3.38 / 800.02 | 2 | 3 |
6 | 13 | 1025.84 | 30 | 13.05 | 1821 | 713 | 4.09 / 800.73 | 2 | 5 |
7 | 13 | 243.48 | 30 | 13.84 | 693 | 288 | 4.38 / 801.02 | 2 | 8 |
8 | 8 | 0.12 | 190 | 14.07 | 339 | 906 | 5.28 / 801.92 | 2 | 22 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 27 | 14.09 | 488 | 186 | 0.19 / 791.49 | 2 | 3 |
2 | 12 | 1113.24 | 5 | 10.60 | 1931 | 102 | 0.29 / 791.60 | 2 | 2 |
3 | 12 | 2001.36 | 42 | 9.80 | 3124 | 1286 | 1.57 / 792.88 | 2 | 2 |
4 | 7 | 1997.84 | 20 | 11.07 | 3199 | 708 | 2.28 / 793.59 | 2 | 2 |
5 | 13 | 1771.12 | 30 | 12.37 | 2881 | 1069 | 3.35 / 794.66 | 2 | 3 |
6 | 13 | 1257.08 | 30 | 12.86 | 2148 | 829 | 4.18 / 795.49 | 2 | 4 |
7 | 13 | 211.12 | 30 | 13.90 | 641 | 267 | 4.45 / 795.75 | 2 | 8 |
8 | 8 | 0.12 | 190 | 14.09 | 331 | 886 | 5.33 / 796.64 | 2 | 19 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 27 | 14.08 | 494 | 188 | 0.19 / 786.23 | 2 | 3 |
2 | 12 | 1121.36 | 5 | 10.36 | 1942 | 101 | 0.29 / 786.33 | 2 | 2 |
3 | 12 | 2002.72 | 42 | 9.81 | 3126 | 1288 | 1.58 / 787.62 | 2 | 2 |
4 | 7 | 1999.24 | 21 | 10.99 | 3194 | 737 | 2.31 / 788.35 | 2 | 2 |
5 | 13 | 1767.88 | 30 | 12.37 | 2876 | 1067 | 3.38 / 789.42 | 2 | 3 |
6 | 13 | 1018.40 | 30 | 13.06 | 1804 | 707 | 4.09 / 790.13 | 2 | 5 |
7 | 13 | 226.40 | 30 | 13.86 | 677 | 281 | 4.37 / 790.41 | 2 | 8 |
8 | 8 | -0.04 | 190 | 14.08 | 336 | 899 | 5.27 / 791.31 | 2 | 19 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 28 | 14.13 | 483 | 191 | 0.19 / 780.97 | 2 | 3 |
2 | 3 | 971.04 | -1 | 14.13 | 483 | 0 | 0.00 / 780.97 | 2 | 3 |
3 | 3 | 1023.72 | 1 | 12.80 | 1857 | 24 | 0.21 / 780.99 | 2 | 2 |
4 | 12 | 1130.00 | 5 | 10.40 | 1946 | 101 | 0.32 / 781.09 | 2 | 2 |
5 | 12 | 2003.36 | 42 | 9.89 | 3125 | 1298 | 1.61 / 782.39 | 2 | 2 |
6 | 7 | 1999.52 | 20 | 11.06 | 3201 | 708 | 2.32 / 783.10 | 2 | 2 |
7 | 13 | 1761.92 | 30 | 12.37 | 2882 | 1070 | 3.39 / 784.17 | 2 | 3 |
8 | 13 | 1024.28 | 30 | 13.08 | 1783 | 700 | 4.09 / 784.87 | 2 | 5 |
9 | 13 | 241.72 | 30 | 13.86 | 687 | 286 | 4.38 / 785.15 | 2 | 8 |
10 | 8 | 0.16 | 190 | 14.08 | 332 | 888 | 5.27 / 786.04 | 2 | 20 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 28 | 14.13 | 485 | 192 | 0.19 / 775.63 | 2 | 3 |
2 | 12 | 1113.36 | 5 | 10.30 | 1928 | 99 | 0.29 / 775.73 | 2 | 2 |
3 | 12 | 2005.40 | 42 | 9.83 | 3125 | 1290 | 1.58 / 777.02 | 2 | 2 |
4 | 7 | 2001.32 | 20 | 11.07 | 3198 | 708 | 2.29 / 777.72 | 2 | 2 |
5 | 13 | 1781.12 | 30 | 12.36 | 2909 | 1079 | 3.37 / 778.80 | 2 | 2 |
6 | 13 | 1276.08 | 30 | 12.86 | 2140 | 826 | 4.19 / 779.63 | 2 | 4 |
7 | 13 | 224.00 | 30 | 13.89 | 660 | 275 | 4.47 / 779.90 | 2 | 8 |
8 | 8 | 0.28 | 190 | 14.10 | 325 | 871 | 5.34 / 780.77 | 2 | 20 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 28 | 14.11 | 490 | 194 | 0.19 / 770.43 | 2 | 2 |
2 | 12 | 1128.48 | 5 | 10.41 | 1943 | 101 | 0.29 / 770.53 | 2 | 2 |
3 | 12 | 2001.40 | 42 | 9.83 | 3124 | 1290 | 1.58 / 771.82 | 2 | 2 |
4 | 7 | 1997.48 | 20 | 11.10 | 3186 | 707 | 2.29 / 772.53 | 2 | 2 |
5 | 13 | 1783.16 | 30 | 12.36 | 2915 | 1081 | 3.37 / 773.61 | 2 | 3 |
6 | 13 | 1047.08 | 30 | 13.07 | 1822 | 714 | 4.09 / 774.32 | 2 | 4 |
7 | 13 | 139.24 | 30 | 14.00 | 538 | 226 | 4.31 / 774.55 | 2 | 8 |
8 | 8 | 0.84 | 190 | 14.11 | 330 | 885 | 5.20 / 775.44 | 2 | 21 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 28 | 14.12 | 486 | 192 | 0.19 / 765.13 | 2 | 2 |
2 | 12 | 1112.48 | 5 | 10.42 | 1935 | 101 | 0.29 / 765.24 | 2 | 2 |
3 | 12 | 2003.44 | 42 | 9.88 | 3125 | 1297 | 1.59 / 766.53 | 2 | 2 |
4 | 7 | 1999.88 | 21 | 11.04 | 3193 | 740 | 2.33 / 767.27 | 2 | 2 |
5 | 13 | 1773.76 | 30 | 12.37 | 2888 | 1072 | 3.40 / 768.34 | 2 | 3 |
6 | 13 | 1032.24 | 30 | 13.06 | 1831 | 717 | 4.12 / 769.06 | 2 | 5 |
7 | 13 | 247.24 | 30 | 13.85 | 702 | 292 | 4.41 / 769.35 | 2 | 8 |
8 | 8 | 0.28 | 190 | 14.10 | 330 | 884 | 5.29 / 770.24 | 2 | 25 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 28 | 14.17 | 467 | 185 | 0.19 / 759.92 | 2 | 2 |
2 | 12 | 1105.40 | 5 | 10.51 | 1925 | 101 | 0.29 / 760.02 | 2 | 2 |
3 | 12 | 2002.60 | 42 | 9.93 | 3117 | 1300 | 1.59 / 761.32 | 2 | 2 |
4 | 7 | 1999.28 | 21 | 11.06 | 3189 | 741 | 2.33 / 762.06 | 2 | 2 |
5 | 13 | 1761.44 | 30 | 12.38 | 2880 | 1070 | 3.40 / 763.13 | 2 | 3 |
6 | 13 | 1016.88 | 30 | 13.07 | 1812 | 710 | 4.11 / 763.84 | 2 | 5 |
7 | 13 | 118.12 | 30 | 14.03 | 509 | 214 | 4.32 / 764.06 | 2 | 8 |
8 | 8 | 0.00 | 190 | 14.09 | 331 | 886 | 5.21 / 764.94 | 2 | 18 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 28 | 14.17 | 471 | 187 | 0.19 / 754.66 | 2 | 2 |
2 | 12 | 1116.72 | 5 | 10.25 | 1938 | 99 | 0.29 / 754.76 | 2 | 2 |
3 | 12 | 2001.00 | 42 | 9.93 | 3124 | 1303 | 1.59 / 756.06 | 2 | 2 |
4 | 7 | 1996.68 | 20 | 11.13 | 3190 | 710 | 2.30 / 756.77 | 2 | 2 |
5 | 13 | 1771.76 | 30 | 12.37 | 2891 | 1073 | 3.37 / 757.85 | 2 | 3 |
6 | 13 | 1050.48 | 30 | 13.05 | 1841 | 721 | 4.09 / 758.57 | 2 | 5 |
7 | 13 | 270.24 | 30 | 13.84 | 724 | 301 | 4.39 / 758.87 | 2 | 8 |
8 | 8 | 0.32 | 190 | 14.11 | 324 | 869 | 5.26 / 759.74 | 2 | 18 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 28 | 14.17 | 470 | 186 | 0.19 / 749.45 | 2 | 2 |
2 | 12 | 1135.00 | 5 | 10.43 | 1957 | 102 | 0.29 / 749.55 | 2 | 2 |
3 | 12 | 2001.24 | 42 | 9.97 | 3135 | 1313 | 1.60 / 750.87 | 2 | 2 |
4 | 7 | 1997.52 | 21 | 11.09 | 3185 | 742 | 2.34 / 751.61 | 2 | 2 |
5 | 13 | 1761.84 | 30 | 12.39 | 2882 | 1071 | 3.41 / 752.68 | 2 | 3 |
6 | 13 | 1006.00 | 30 | 13.09 | 1790 | 703 | 4.12 / 753.38 | 2 | 5 |
7 | 13 | 110.36 | 30 | 14.06 | 490 | 207 | 4.32 / 753.59 | 2 | 8 |
8 | 8 | 0.48 | 190 | 14.11 | 330 | 885 | 5.21 / 754.47 | 2 | 23 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 28 | 14.17 | 471 | 187 | 0.19 / 744.25 | 2 | 2 |
2 | 12 | 1125.44 | 5 | 10.33 | 1950 | 101 | 0.29 / 744.35 | 2 | 2 |
3 | 12 | 2004.76 | 42 | 10.02 | 3134 | 1319 | 1.61 / 745.67 | 2 | 2 |
4 | 7 | 2000.56 | 20 | 11.14 | 3196 | 712 | 2.32 / 746.38 | 2 | 2 |
5 | 13 | 1767.36 | 30 | 12.39 | 2889 | 1074 | 3.39 / 747.45 | 2 | 3 |
6 | 13 | 1024.08 | 30 | 13.08 | 1808 | 709 | 4.10 / 748.16 | 2 | 5 |
7 | 13 | 119.64 | 30 | 14.02 | 512 | 215 | 4.32 / 748.38 | 2 | 8 |
8 | 8 | -0.16 | 190 | 14.09 | 331 | 886 | 5.20 / 749.26 | 2 | 20 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 27 | 14.15 | 467 | 178 | 0.18 / 738.96 | 2 | 2 |
2 | 12 | 1137.76 | 5 | 10.29 | 1961 | 101 | 0.28 / 739.06 | 2 | 2 |
3 | 12 | 2001.64 | 42 | 10.09 | 3128 | 1326 | 1.60 / 740.39 | 2 | 2 |
4 | 7 | 1997.80 | 21 | 11.08 | 3177 | 739 | 2.34 / 741.13 | 2 | 2 |
5 | 13 | 1777.40 | 30 | 12.39 | 2892 | 1075 | 3.42 / 742.20 | 2 | 3 |
6 | 13 | 1023.88 | 30 | 13.08 | 1802 | 707 | 4.13 / 742.91 | 2 | 5 |
7 | 13 | 230.16 | 30 | 13.89 | 664 | 277 | 4.40 / 743.19 | 2 | 8 |
8 | 8 | 0.04 | 190 | 14.10 | 326 | 873 | 5.28 / 744.06 | 2 | 21 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 27 | 14.13 | 481 | 184 | 0.18 / 733.63 | 2 | 3 |
2 | 3 | 1019.36 | 1 | 12.76 | 1856 | 24 | 0.21 / 733.66 | 2 | 2 |
3 | 12 | 1135.96 | 5 | 11.02 | 1982 | 109 | 0.32 / 733.77 | 2 | 2 |
4 | 12 | 2003.84 | 42 | 10.12 | 3140 | 1335 | 1.65 / 735.10 | 2 | 2 |
5 | 7 | 1999.84 | 21 | 11.09 | 3189 | 743 | 2.39 / 735.84 | 2 | 2 |
6 | 13 | 1774.96 | 30 | 12.38 | 2898 | 1076 | 3.47 / 736.92 | 2 | 3 |
7 | 13 | 1005.80 | 30 | 13.09 | 1786 | 701 | 4.17 / 737.62 | 2 | 5 |
8 | 13 | 222.84 | 30 | 13.89 | 659 | 275 | 4.45 / 737.90 | 2 | 8 |
9 | 8 | 0.16 | 190 | 14.08 | 332 | 888 | 5.33 / 738.78 | 2 | 18 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 28 | 14.13 | 486 | 192 | 0.19 / 728.41 | 2 | 3 |
2 | 3 | 968.00 | -1 | 14.13 | 486 | 0 | 0.00 / 728.41 | 2 | 3 |
3 | 3 | 1020.32 | 1 | 12.47 | 1864 | 23 | 0.22 / 728.43 | 2 | 2 |
4 | 12 | 1133.08 | 5 | 10.61 | 1971 | 105 | 0.32 / 728.54 | 2 | 2 |
5 | 12 | 2003.40 | 42 | 10.10 | 3146 | 1335 | 1.65 / 729.87 | 2 | 2 |
6 | 7 | 1999.24 | 20 | 11.16 | 3188 | 712 | 2.37 / 730.58 | 2 | 2 |
7 | 13 | 1765.04 | 30 | 12.37 | 2878 | 1068 | 3.43 / 731.65 | 2 | 3 |
8 | 13 | 1005.84 | 30 | 13.08 | 1791 | 703 | 4.14 / 732.36 | 2 | 5 |
9 | 13 | 105.96 | 30 | 14.04 | 493 | 208 | 4.34 / 732.56 | 2 | 8 |
10 | 8 | 0.12 | 190 | 14.07 | 332 | 888 | 5.23 / 733.45 | 2 | 19 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 28 | 14.14 | 474 | 188 | 0.19 / 723.19 | 2 | 3 |
2 | 12 | 1096.68 | 5 | 10.31 | 1904 | 98 | 0.29 / 723.29 | 2 | 2 |
3 | 12 | 2003.72 | 42 | 10.04 | 3122 | 1316 | 1.60 / 724.60 | 2 | 2 |
4 | 7 | 2000.16 | 21 | 11.07 | 3192 | 742 | 2.34 / 725.35 | 2 | 2 |
5 | 13 | 1781.32 | 30 | 12.35 | 2901 | 1075 | 3.42 / 726.42 | 2 | 3 |
6 | 13 | 1019.32 | 30 | 13.08 | 1772 | 695 | 4.11 / 727.12 | 2 | 5 |
7 | 13 | 124.40 | 30 | 14.02 | 516 | 217 | 4.33 / 727.33 | 2 | 8 |
8 | 8 | 0.04 | 190 | 14.08 | 331 | 885 | 5.22 / 728.22 | 2 | 16 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 28 | 14.13 | 473 | 187 | 0.19 / 717.92 | 2 | 3 |
2 | 12 | 1098.76 | 5 | 10.18 | 1894 | 96 | 0.28 / 718.01 | 2 | 2 |
3 | 12 | 2003.20 | 42 | 10.03 | 3117 | 1313 | 1.60 / 719.33 | 2 | 2 |
4 | 7 | 1999.40 | 21 | 11.05 | 3199 | 742 | 2.34 / 720.07 | 2 | 2 |
5 | 13 | 1773.16 | 30 | 12.36 | 2892 | 1072 | 3.41 / 721.14 | 2 | 3 |
6 | 13 | 1000.56 | 30 | 13.08 | 1788 | 702 | 4.11 / 721.84 | 2 | 5 |
7 | 13 | 216.40 | 30 | 13.91 | 653 | 272 | 4.39 / 722.12 | 2 | 8 |
8 | 8 | 0.12 | 190 | 14.09 | 331 | 886 | 5.27 / 723.00 | 2 | 18 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 28 | 14.16 | 480 | 190 | 0.19 / 712.68 | 2 | 3 |
2 | 12 | 1129.00 | 5 | 10.38 | 1943 | 101 | 0.29 / 712.78 | 2 | 2 |
3 | 12 | 2008.08 | 42 | 10.09 | 3133 | 1328 | 1.62 / 714.11 | 2 | 2 |
4 | 7 | 2005.04 | 21 | 11.07 | 3199 | 744 | 2.36 / 714.86 | 2 | 2 |
5 | 13 | 1767.92 | 30 | 12.39 | 2888 | 1073 | 3.44 / 715.93 | 2 | 3 |
6 | 13 | 1033.24 | 30 | 13.07 | 1833 | 719 | 4.15 / 716.65 | 2 | 5 |
7 | 13 | 118.80 | 30 | 14.07 | 502 | 212 | 4.37 / 716.86 | 2 | 8 |
8 | 8 | 0.08 | 190 | 14.13 | 324 | 870 | 5.24 / 717.73 | 2 | 20 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 28 | 14.14 | 477 | 189 | 0.19 / 707.29 | 2 | 3 |
2 | 12 | 1109.40 | 5 | 10.44 | 1922 | 100 | 0.29 / 707.39 | 2 | 2 |
3 | 12 | 2004.92 | 42 | 10.02 | 3128 | 1316 | 1.61 / 708.70 | 2 | 2 |
4 | 7 | 2001.08 | 21 | 11.08 | 3193 | 743 | 2.35 / 709.45 | 2 | 2 |
5 | 13 | 1776.00 | 30 | 12.36 | 2900 | 1075 | 3.42 / 710.52 | 2 | 2 |
6 | 13 | 1260.40 | 30 | 12.87 | 2146 | 829 | 4.25 / 711.35 | 2 | 4 |
7 | 13 | 192.80 | 30 | 13.96 | 621 | 260 | 4.51 / 711.61 | 2 | 8 |
8 | 8 | 0.20 | 190 | 14.13 | 329 | 883 | 5.40 / 712.49 | 2 | 20 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 28 | 14.13 | 487 | 193 | 0.19 / 702.06 | 2 | 3 |
2 | 12 | 1123.68 | 5 | 10.67 | 1944 | 104 | 0.30 / 702.16 | 2 | 2 |
3 | 12 | 2001.04 | 42 | 10.08 | 3133 | 1326 | 1.62 / 703.49 | 2 | 2 |
4 | 7 | 1996.36 | 21 | 11.12 | 3184 | 744 | 2.37 / 704.23 | 2 | 2 |
5 | 13 | 1766.88 | 30 | 12.38 | 2886 | 1072 | 3.44 / 705.30 | 2 | 3 |
6 | 13 | 1031.76 | 30 | 13.08 | 1825 | 716 | 4.15 / 706.02 | 2 | 5 |
7 | 13 | 117.76 | 30 | 14.07 | 502 | 212 | 4.37 / 706.23 | 2 | 7 |
8 | 8 | 0.04 | 190 | 14.14 | 322 | 865 | 5.23 / 707.10 | 2 | 23 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 28 | 14.13 | 489 | 193 | 0.19 / 696.84 | 2 | 3 |
2 | 12 | 1111.68 | 5 | 10.95 | 1929 | 106 | 0.30 / 696.94 | 2 | 2 |
3 | 12 | 2004.44 | 42 | 10.15 | 3147 | 1342 | 1.64 / 698.28 | 2 | 2 |
4 | 7 | 2000.84 | 21 | 11.13 | 3191 | 746 | 2.39 / 699.03 | 2 | 2 |
5 | 13 | 1763.36 | 30 | 12.37 | 2871 | 1065 | 3.45 / 700.09 | 2 | 3 |
6 | 13 | 1006.68 | 30 | 13.08 | 1802 | 707 | 4.16 / 700.80 | 2 | 5 |
7 | 13 | 103.20 | 30 | 14.09 | 478 | 202 | 4.36 / 701.00 | 2 | 8 |
8 | 8 | 0.48 | 190 | 14.12 | 322 | 864 | 5.22 / 701.87 | 2 | 18 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 27 | 14.13 | 491 | 187 | 0.19 / 691.40 | 2 | 2 |
2 | 3 | 1022.04 | 1 | 12.34 | 1845 | 23 | 0.21 / 691.43 | 2 | 2 |
3 | 12 | 1128.56 | 5 | 10.97 | 1961 | 108 | 0.32 / 691.53 | 2 | 2 |
4 | 12 | 2002.16 | 42 | 10.21 | 3149 | 1350 | 1.67 / 692.88 | 2 | 2 |
5 | 7 | 1998.88 | 21 | 11.10 | 3187 | 743 | 2.41 / 693.63 | 2 | 2 |
6 | 13 | 1775.80 | 30 | 12.37 | 2898 | 1075 | 3.49 / 694.70 | 2 | 3 |
7 | 13 | 1021.16 | 30 | 13.09 | 1805 | 709 | 4.20 / 695.41 | 2 | 5 |
8 | 13 | 112.04 | 30 | 14.06 | 502 | 212 | 4.41 / 695.62 | 2 | 8 |
9 | 13 | 2.64 | 30 | 14.25 | 334 | 143 | 4.55 / 695.77 | 2 | 11 |
10 | 8 | -0.32 | 190 | 14.09 | 327 | 875 | 5.43 / 696.64 | 2 | 24 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 28 | 14.14 | 478 | 189 | 0.19 / 686.09 | 2 | 3 |
2 | 3 | 964.20 | -1 | 14.14 | 478 | 0 | 0.00 / 686.09 | 2 | 3 |
3 | 12 | 1150.68 | 5 | 11.25 | 1992 | 112 | 0.30 / 686.20 | 2 | 2 |
4 | 12 | 2003.72 | 42 | 10.34 | 3162 | 1373 | 1.67 / 687.57 | 2 | 2 |
5 | 7 | 1999.00 | 21 | 11.12 | 3188 | 744 | 2.42 / 688.32 | 2 | 2 |
6 | 13 | 1772.92 | 30 | 12.37 | 2888 | 1072 | 3.49 / 689.39 | 2 | 3 |
7 | 13 | 1006.56 | 30 | 13.09 | 1798 | 706 | 4.20 / 690.09 | 2 | 5 |
8 | 13 | 188.56 | 30 | 13.98 | 605 | 254 | 4.45 / 690.35 | 2 | 8 |
9 | 8 | 0.48 | 190 | 14.13 | 324 | 870 | 5.32 / 691.22 | 2 | 18 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.12 | 28 | 14.12 | 512 | 202 | 0.20 / 680.83 | 2 | 2 |
2 | 12 | 1108.36 | 5 | 11.20 | 1918 | 107 | 0.31 / 680.94 | 2 | 2 |
3 | 12 | 2004.52 | 42 | 10.32 | 3143 | 1362 | 1.67 / 682.30 | 2 | 2 |
4 | 7 | 1999.84 | 21 | 11.11 | 3200 | 747 | 2.42 / 683.05 | 2 | 2 |
5 | 13 | 1769.24 | 30 | 12.39 | 2882 | 1071 | 3.49 / 684.12 | 2 | 3 |
6 | 13 | 1007.16 | 30 | 13.09 | 1782 | 700 | 4.19 / 684.82 | 2 | 5 |
7 | 13 | 102.60 | 30 | 14.08 | 483 | 204 | 4.39 / 685.02 | 2 | 8 |
8 | 8 | -0.12 | 190 | 14.11 | 326 | 874 | 5.27 / 685.90 | 2 | 20 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 28 | 14.15 | 493 | 195 | 0.20 / 675.49 | 2 | 3 |
2 | 12 | 1128.64 | 5 | 11.58 | 1957 | 113 | 0.31 / 675.60 | 2 | 2 |
3 | 12 | 2006.68 | 42 | 10.35 | 3144 | 1367 | 1.68 / 676.97 | 2 | 2 |
4 | 7 | 2002.16 | 21 | 11.13 | 3191 | 746 | 2.42 / 677.72 | 2 | 2 |
5 | 13 | 1552.76 | 30 | 12.58 | 2562 | 967 | 3.39 / 678.68 | 2 | 3 |
6 | 13 | 1081.48 | 30 | 13.03 | 1879 | 735 | 4.12 / 679.42 | 2 | 5 |
7 | 13 | 49.72 | 30 | 14.15 | 404 | 171 | 4.29 / 679.59 | 2 | 8 |
8 | 13 | 9.36 | 30 | 14.18 | 349 | 148 | 4.44 / 679.74 | 2 | 10 |
9 | 8 | -0.16 | 190 | 14.07 | 333 | 890 | 5.33 / 680.63 | 2 | 30 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 28 | 14.17 | 479 | 190 | 0.19 / 670.31 | 2 | 3 |
2 | 12 | 1118.08 | 5 | 11.73 | 1949 | 114 | 0.30 / 670.42 | 2 | 2 |
3 | 12 | 2005.12 | 42 | 10.31 | 3159 | 1368 | 1.67 / 671.79 | 2 | 2 |
4 | 7 | 2001.48 | 21 | 11.14 | 3185 | 745 | 2.42 / 672.54 | 2 | 2 |
5 | 13 | 1768.68 | 30 | 12.36 | 2884 | 1069 | 3.49 / 673.61 | 2 | 3 |
6 | 13 | 796.44 | 30 | 13.28 | 1503 | 599 | 4.09 / 674.21 | 2 | 6 |
7 | 13 | 122.08 | 30 | 14.06 | 512 | 216 | 4.30 / 674.42 | 2 | 8 |
8 | 8 | 0.32 | 190 | 14.12 | 326 | 875 | 5.18 / 675.30 | 2 | 24 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 28 | 14.15 | 481 | 191 | 0.19 / 665.00 | 2 | 3 |
2 | 3 | 973.16 | -1 | 14.15 | 481 | 0 | 0.00 / 665.00 | 2 | 3 |
3 | 3 | 1020.36 | 1 | 11.81 | 1839 | 22 | 0.21 / 665.03 | 2 | 2 |
4 | 12 | 1132.96 | 5 | 11.81 | 1971 | 116 | 0.33 / 665.14 | 2 | 2 |
5 | 12 | 2004.16 | 42 | 10.43 | 3167 | 1387 | 1.72 / 666.53 | 2 | 2 |
6 | 7 | 1999.80 | 21 | 11.13 | 3190 | 746 | 2.46 / 667.28 | 2 | 2 |
7 | 13 | 1767.36 | 30 | 12.35 | 2876 | 1066 | 3.53 / 668.34 | 2 | 2 |
8 | 13 | 1008.80 | 30 | 13.09 | 1789 | 703 | 4.23 / 669.04 | 2 | 5 |
9 | 13 | 102.48 | 30 | 14.08 | 483 | 204 | 4.43 / 669.25 | 2 | 8 |
10 | 8 | 0.00 | 190 | 14.12 | 325 | 872 | 5.31 / 670.12 | 2 | 21 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 27 | 14.14 | 495 | 189 | 0.19 / 659.59 | 2 | 3 |
2 | 3 | 1037.76 | 1 | 12.60 | 1861 | 23 | 0.21 / 659.61 | 2 | 2 |
3 | 3 | 1019.60 | 1 | 12.17 | 1844 | 22 | 0.23 / 659.64 | 2 | 2 |
4 | 12 | 1130.48 | 5 | 11.92 | 1965 | 117 | 0.35 / 659.75 | 2 | 2 |
5 | 12 | 2005.48 | 42 | 10.44 | 3191 | 1399 | 1.75 / 661.15 | 2 | 2 |
6 | 7 | 2001.12 | 21 | 11.12 | 3189 | 745 | 2.50 / 661.90 | 2 | 2 |
7 | 13 | 1774.96 | 30 | 12.33 | 2893 | 1070 | 3.57 / 662.97 | 2 | 2 |
8 | 13 | 1011.64 | 30 | 13.07 | 1796 | 704 | 4.27 / 663.67 | 2 | 5 |
9 | 13 | 211.16 | 30 | 13.94 | 646 | 270 | 4.54 / 663.94 | 2 | 8 |
10 | 8 | -0.04 | 190 | 14.13 | 325 | 873 | 5.41 / 664.81 | 2 | 19 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 28 | 14.15 | 472 | 187 | 0.19 / 654.30 | 2 | 2 |
2 | 3 | 941.40 | -1 | 14.15 | 472 | 0 | 0.00 / 654.30 | 2 | 2 |
3 | 12 | 1126.68 | 5 | 11.96 | 1965 | 118 | 0.30 / 654.42 | 2 | 2 |
4 | 12 | 2004.56 | 42 | 10.43 | 3190 | 1397 | 1.70 / 655.81 | 2 | 2 |
5 | 7 | 2000.56 | 21 | 11.11 | 3199 | 746 | 2.45 / 656.56 | 2 | 2 |
6 | 13 | 1779.20 | 30 | 12.32 | 2902 | 1073 | 3.52 / 657.63 | 2 | 2 |
7 | 13 | 1002.16 | 30 | 13.08 | 1788 | 702 | 4.22 / 658.33 | 2 | 5 |
8 | 13 | 103.56 | 30 | 14.09 | 481 | 203 | 4.43 / 658.54 | 2 | 8 |
9 | 8 | 0.16 | 190 | 14.13 | 322 | 864 | 5.29 / 659.40 | 2 | 20 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 28 | 14.15 | 487 | 193 | 0.19 / 649.04 | 2 | 2 |
2 | 12 | 1103.80 | 5 | 11.99 | 1922 | 115 | 0.31 / 649.16 | 2 | 2 |
3 | 12 | 2004.36 | 42 | 10.44 | 3193 | 1400 | 1.71 / 650.56 | 2 | 2 |
4 | 7 | 2000.48 | 21 | 11.09 | 3192 | 743 | 2.45 / 651.30 | 2 | 2 |
5 | 13 | 1770.72 | 30 | 12.30 | 2894 | 1068 | 3.52 / 652.37 | 2 | 2 |
6 | 13 | 985.92 | 30 | 13.09 | 1757 | 690 | 4.21 / 653.06 | 2 | 5 |
7 | 13 | 92.36 | 30 | 14.10 | 462 | 195 | 4.40 / 653.25 | 2 | 7 |
8 | 8 | 0.00 | 190 | 14.13 | 319 | 856 | 5.26 / 654.11 | 2 | 20 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 28 | 14.14 | 485 | 192 | 0.19 / 643.79 | 2 | 2 |
2 | 12 | 1116.04 | 5 | 12.00 | 1946 | 117 | 0.31 / 643.91 | 2 | 2 |
3 | 12 | 2001.68 | 42 | 10.50 | 3182 | 1403 | 1.71 / 645.31 | 2 | 2 |
4 | 7 | 1996.72 | 21 | 11.10 | 3178 | 741 | 2.45 / 646.05 | 2 | 2 |
5 | 13 | 1761.08 | 30 | 12.33 | 2853 | 1055 | 3.51 / 647.11 | 2 | 2 |
6 | 13 | 982.24 | 30 | 13.09 | 1752 | 688 | 4.20 / 647.80 | 2 | 5 |
7 | 13 | 92.20 | 30 | 14.10 | 460 | 195 | 4.39 / 647.99 | 2 | 8 |
8 | 8 | 0.08 | 190 | 14.12 | 320 | 858 | 5.25 / 648.85 | 2 | 20 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 28 | 14.14 | 480 | 190 | 0.19 / 638.49 | 2 | 3 |
2 | 12 | 1107.76 | 5 | 11.96 | 1932 | 116 | 0.31 / 638.61 | 2 | 2 |
3 | 12 | 2004.60 | 42 | 10.48 | 3200 | 1409 | 1.71 / 640.02 | 2 | 2 |
4 | 7 | 1999.44 | 21 | 11.10 | 3188 | 743 | 2.46 / 640.76 | 2 | 2 |
5 | 13 | 1763.96 | 30 | 12.29 | 2884 | 1063 | 3.52 / 641.82 | 2 | 2 |
6 | 13 | 1005.64 | 30 | 13.06 | 1792 | 702 | 4.22 / 642.53 | 2 | 5 |
7 | 13 | 99.84 | 30 | 14.08 | 478 | 202 | 4.42 / 642.73 | 2 | 8 |
8 | 8 | 0.20 | 190 | 14.12 | 325 | 872 | 5.30 / 643.60 | 2 | 23 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 28 | 14.15 | 482 | 191 | 0.19 / 633.41 | 2 | 2 |
2 | 12 | 1134.44 | 5 | 11.96 | 1966 | 118 | 0.31 / 633.52 | 2 | 2 |
3 | 12 | 2001.04 | 42 | 10.57 | 3187 | 1415 | 1.72 / 634.94 | 2 | 2 |
4 | 7 | 1995.88 | 21 | 11.08 | 3186 | 741 | 2.46 / 635.68 | 2 | 2 |
5 | 13 | 1753.32 | 30 | 12.32 | 2868 | 1060 | 3.52 / 636.74 | 2 | 2 |
6 | 13 | 977.48 | 30 | 13.08 | 1758 | 690 | 4.21 / 637.43 | 2 | 5 |
7 | 8 | 0.36 | 190 | 14.10 | 326 | 873 | 5.09 / 638.30 | 2 | 19 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 28 | 14.17 | 482 | 191 | 0.19 / 628.27 | 2 | 2 |
2 | 12 | 1117.92 | 5 | 11.98 | 1953 | 117 | 0.31 / 628.39 | 2 | 2 |
3 | 12 | 2003.76 | 42 | 10.66 | 3178 | 1423 | 1.73 / 629.81 | 2 | 2 |
4 | 7 | 1998.20 | 21 | 11.10 | 3183 | 742 | 2.47 / 630.55 | 2 | 2 |
5 | 13 | 1536.56 | 30 | 12.52 | 2551 | 958 | 3.43 / 631.51 | 2 | 3 |
6 | 13 | 825.40 | 30 | 13.23 | 1543 | 612 | 4.04 / 632.12 | 2 | 6 |
7 | 13 | 129.60 | 30 | 14.03 | 522 | 220 | 4.26 / 632.34 | 2 | 8 |
8 | 8 | 0.00 | 190 | 14.10 | 326 | 873 | 5.14 / 633.22 | 2 | 17 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 29 | 14.18 | 483 | 199 | 0.20 / 622.95 | 2 | 2 |
2 | 3 | 971.24 | -1 | 14.18 | 483 | 0 | 0.00 / 622.95 | 2 | 2 |
3 | 3 | 1027.56 | 1 | 12.00 | 1832 | 22 | 0.22 / 622.97 | 2 | 2 |
4 | 12 | 1141.28 | 5 | 11.98 | 1982 | 119 | 0.34 / 623.09 | 2 | 2 |
5 | 12 | 2002.72 | 42 | 10.72 | 3184 | 1434 | 1.77 / 624.53 | 2 | 2 |
6 | 7 | 1997.28 | 21 | 11.09 | 3185 | 742 | 2.51 / 625.27 | 2 | 2 |
7 | 13 | 1760.48 | 30 | 12.31 | 2866 | 1058 | 3.57 / 626.33 | 2 | 2 |
8 | 13 | 985.52 | 30 | 13.07 | 1772 | 695 | 4.27 / 627.02 | 2 | 5 |
9 | 13 | 85.88 | 30 | 14.10 | 455 | 192 | 4.46 / 627.21 | 2 | 8 |
10 | 8 | -0.20 | 190 | 14.11 | 323 | 866 | 5.33 / 628.08 | 2 | 18 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 28 | 14.19 | 471 | 187 | 0.19 / 617.63 | 2 | 2 |
2 | 3 | 1023.36 | 1 | 12.18 | 1849 | 23 | 0.21 / 617.65 | 2 | 2 |
3 | 12 | 1141.04 | 5 | 11.97 | 1970 | 118 | 0.33 / 617.77 | 2 | 2 |
4 | 12 | 2002.04 | 42 | 10.75 | 3186 | 1438 | 1.77 / 619.20 | 2 | 2 |
5 | 7 | 1996.84 | 21 | 11.11 | 3193 | 745 | 2.51 / 619.95 | 2 | 2 |
6 | 13 | 1763.96 | 30 | 12.30 | 2883 | 1064 | 3.57 / 621.01 | 2 | 3 |
7 | 13 | 982.40 | 30 | 13.07 | 1771 | 694 | 4.27 / 621.71 | 2 | 5 |
8 | 13 | 45.28 | 30 | 14.16 | 394 | 167 | 4.44 / 621.88 | 2 | 8 |
9 | 8 | 0.12 | 190 | 14.08 | 328 | 877 | 5.31 / 622.75 | 2 | 18 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 29 | 14.19 | 468 | 193 | 0.19 / 612.29 | 2 | 2 |
2 | 3 | 970.04 | -1 | 14.19 | 468 | 0 | 0.00 / 612.29 | 2 | 2 |
3 | 3 | 1033.48 | 1 | 12.11 | 1841 | 22 | 0.21 / 612.31 | 2 | 2 |
4 | 12 | 1144.96 | 5 | 11.95 | 1997 | 119 | 0.33 / 612.43 | 2 | 2 |
5 | 12 | 2000.68 | 42 | 10.72 | 3186 | 1434 | 1.77 / 613.86 | 2 | 2 |
6 | 7 | 1995.40 | 21 | 11.08 | 3189 | 742 | 2.51 / 614.61 | 2 | 2 |
7 | 13 | 1766.88 | 30 | 12.27 | 2884 | 1062 | 3.57 / 615.67 | 2 | 3 |
8 | 13 | 993.12 | 30 | 13.05 | 1778 | 696 | 4.27 / 616.36 | 2 | 5 |
9 | 13 | 90.28 | 30 | 14.09 | 471 | 199 | 4.47 / 616.56 | 2 | 8 |
10 | 8 | 0.00 | 190 | 14.10 | 327 | 876 | 5.34 / 617.44 | 2 | 16 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 28 | 14.20 | 464 | 184 | 0.18 / 607.11 | 2 | 2 |
2 | 12 | 1124.36 | 5 | 12.03 | 1967 | 118 | 0.30 / 607.23 | 2 | 2 |
3 | 12 | 2001.40 | 42 | 10.80 | 3190 | 1447 | 1.75 / 608.68 | 2 | 2 |
4 | 7 | 1996.60 | 21 | 11.11 | 3188 | 744 | 2.49 / 609.42 | 2 | 2 |
5 | 13 | 1756.28 | 30 | 12.30 | 2863 | 1056 | 3.55 / 610.48 | 2 | 2 |
6 | 13 | 757.04 | 30 | 13.29 | 1444 | 576 | 4.13 / 611.05 | 2 | 6 |
7 | 13 | 46.12 | 30 | 14.16 | 399 | 169 | 4.30 / 611.22 | 2 | 8 |
8 | 8 | 0.28 | 190 | 14.08 | 327 | 875 | 5.17 / 612.10 | 2 | 18 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 28 | 14.20 | 466 | 185 | 0.19 / 601.82 | 2 | 2 |
2 | 12 | 1132.64 | 5 | 12.05 | 1975 | 119 | 0.30 / 601.94 | 2 | 2 |
3 | 12 | 2003.04 | 42 | 10.73 | 3195 | 1440 | 1.74 / 603.38 | 2 | 2 |
4 | 7 | 1997.20 | 21 | 11.07 | 3191 | 742 | 2.49 / 604.12 | 2 | 2 |
5 | 13 | 1762.96 | 30 | 12.26 | 2875 | 1057 | 3.54 / 605.18 | 2 | 3 |
6 | 13 | 990.24 | 30 | 13.06 | 1756 | 688 | 4.23 / 605.87 | 2 | 5 |
7 | 13 | 80.36 | 30 | 14.10 | 449 | 190 | 4.42 / 606.06 | 2 | 8 |
8 | 8 | 0.00 | 190 | 14.09 | 325 | 870 | 5.29 / 606.93 | 2 | 16 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 29 | 14.21 | 463 | 191 | 0.19 / 596.70 | 2 | 2 |
2 | 3 | 964.88 | -1 | 14.21 | 463 | 0 | 0.00 / 596.70 | 2 | 2 |
3 | 3 | 1023.56 | 1 | 11.51 | 1837 | 21 | 0.21 / 596.72 | 2 | 2 |
4 | 12 | 1147.92 | 5 | 12.00 | 2001 | 120 | 0.33 / 596.84 | 2 | 2 |
5 | 12 | 2004.52 | 42 | 10.79 | 3200 | 1450 | 1.78 / 598.29 | 2 | 2 |
6 | 7 | 2000.00 | 21 | 11.08 | 3195 | 743 | 2.53 / 599.03 | 2 | 2 |
7 | 13 | 1542.08 | 30 | 12.50 | 2552 | 957 | 3.48 / 599.99 | 2 | 3 |
8 | 13 | 804.04 | 30 | 13.23 | 1510 | 599 | 4.08 / 600.59 | 2 | 6 |
9 | 13 | 55.96 | 30 | 14.14 | 410 | 174 | 4.26 / 600.77 | 2 | 8 |
10 | 8 | 0.12 | 190 | 14.07 | 325 | 869 | 5.12 / 601.63 | 2 | 20 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 29 | 14.18 | 476 | 196 | 0.20 / 591.55 | 2 | 2 |
2 | 12 | 1110.08 | 5 | 12.00 | 1949 | 117 | 0.31 / 591.67 | 2 | 2 |
3 | 12 | 2000.88 | 42 | 10.78 | 3195 | 1447 | 1.76 / 593.11 | 2 | 2 |
4 | 7 | 1996.40 | 21 | 11.05 | 3197 | 742 | 2.50 / 593.85 | 2 | 2 |
5 | 13 | 1547.84 | 30 | 12.49 | 2575 | 965 | 3.47 / 594.82 | 2 | 3 |
6 | 13 | 816.60 | 30 | 13.22 | 1532 | 608 | 4.07 / 595.43 | 2 | 6 |
7 | 13 | 123.72 | 30 | 14.03 | 515 | 217 | 4.29 / 595.64 | 2 | 8 |
8 | 8 | 0.16 | 190 | 14.10 | 323 | 865 | 5.16 / 596.51 | 2 | 19 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 29 | 14.15 | 491 | 201 | 0.20 / 586.44 | 2 | 2 |
2 | 12 | 1099.88 | 5 | 12.03 | 1924 | 116 | 0.32 / 586.56 | 2 | 2 |
3 | 12 | 2001.88 | 42 | 10.79 | 3190 | 1446 | 1.76 / 588.00 | 2 | 2 |
4 | 7 | 1996.28 | 21 | 11.07 | 3186 | 741 | 2.50 / 588.74 | 2 | 2 |
5 | 13 | 1552.64 | 30 | 12.49 | 2583 | 968 | 3.47 / 589.71 | 2 | 3 |
6 | 13 | 817.04 | 30 | 13.22 | 1532 | 608 | 4.08 / 590.32 | 2 | 6 |
7 | 13 | 29.72 | 30 | 14.18 | 375 | 160 | 4.24 / 590.48 | 2 | 8 |
8 | 8 | 0.20 | 190 | 14.06 | 328 | 876 | 5.11 / 591.35 | 2 | 20 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 29 | 14.19 | 479 | 197 | 0.20 / 581.10 | 2 | 2 |
2 | 12 | 1118.32 | 5 | 12.00 | 1959 | 118 | 0.31 / 581.22 | 2 | 2 |
3 | 12 | 2007.16 | 42 | 10.75 | 3198 | 1444 | 1.76 / 582.66 | 2 | 2 |
4 | 7 | 2002.60 | 21 | 11.07 | 3189 | 741 | 2.50 / 583.41 | 2 | 2 |
5 | 13 | 1773.20 | 30 | 12.24 | 2897 | 1064 | 3.56 / 584.47 | 2 | 2 |
6 | 13 | 982.92 | 30 | 13.04 | 1766 | 691 | 4.25 / 585.16 | 2 | 5 |
7 | 13 | 79.68 | 30 | 14.08 | 454 | 192 | 4.45 / 585.35 | 2 | 8 |
8 | 8 | -0.24 | 190 | 14.07 | 332 | 888 | 5.33 / 586.24 | 2 | 20 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 29 | 14.19 | 474 | 195 | 0.20 / 575.80 | 2 | 2 |
2 | 12 | 1114.20 | 5 | 12.05 | 1952 | 118 | 0.31 / 575.92 | 2 | 2 |
3 | 12 | 2000.24 | 42 | 10.81 | 3185 | 1446 | 1.76 / 577.36 | 2 | 2 |
4 | 7 | 1995.56 | 21 | 11.06 | 3185 | 740 | 2.50 / 578.10 | 2 | 2 |
5 | 13 | 1755.80 | 30 | 12.25 | 2867 | 1054 | 3.55 / 579.16 | 2 | 3 |
6 | 13 | 991.20 | 30 | 13.03 | 1778 | 695 | 4.25 / 579.85 | 2 | 5 |
7 | 13 | 41.16 | 30 | 14.14 | 395 | 168 | 4.41 / 580.02 | 2 | 8 |
8 | 8 | 0.08 | 190 | 14.05 | 332 | 886 | 5.30 / 580.91 | 2 | 22 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 29 | 14.16 | 475 | 195 | 0.20 / 570.48 | 2 | 2 |
2 | 12 | 1119.60 | 5 | 12.03 | 1960 | 118 | 0.31 / 570.60 | 2 | 2 |
3 | 12 | 2005.20 | 42 | 10.75 | 3201 | 1445 | 1.76 / 572.04 | 2 | 2 |
4 | 7 | 2001.12 | 21 | 11.03 | 3201 | 741 | 2.50 / 572.78 | 2 | 2 |
5 | 13 | 1759.80 | 30 | 12.24 | 2878 | 1057 | 3.56 / 573.84 | 2 | 3 |
6 | 13 | 975.16 | 30 | 13.03 | 1771 | 692 | 4.25 / 574.53 | 2 | 6 |
7 | 13 | 46.56 | 30 | 14.13 | 413 | 175 | 4.42 / 574.71 | 2 | 8 |
8 | 8 | 0.12 | 190 | 14.04 | 336 | 896 | 5.32 / 575.60 | 2 | 19 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 29 | 14.16 | 474 | 195 | 0.19 / 565.37 | 2 | 2 |
2 | 12 | 1115.20 | 5 | 12.05 | 1955 | 118 | 0.31 / 565.48 | 2 | 2 |
3 | 12 | 2002.16 | 42 | 10.83 | 3197 | 1454 | 1.77 / 566.94 | 2 | 2 |
4 | 7 | 1997.12 | 21 | 11.03 | 3187 | 738 | 2.50 / 567.68 | 2 | 2 |
5 | 13 | 1532.24 | 30 | 12.48 | 2540 | 951 | 3.46 / 568.63 | 2 | 3 |
6 | 13 | 803.24 | 30 | 13.22 | 1517 | 602 | 4.06 / 569.23 | 2 | 6 |
7 | 13 | 57.24 | 30 | 14.12 | 420 | 178 | 4.24 / 569.41 | 2 | 8 |
8 | 8 | 0.16 | 190 | 14.04 | 329 | 878 | 5.11 / 570.28 | 2 | 19 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 29 | 14.17 | 481 | 198 | 0.20 / 560.05 | 2 | 2 |
2 | 12 | 1119.76 | 5 | 12.07 | 1962 | 118 | 0.32 / 560.17 | 2 | 2 |
3 | 12 | 2000.92 | 42 | 10.83 | 3191 | 1451 | 1.77 / 561.62 | 2 | 2 |
4 | 7 | 1996.48 | 21 | 11.06 | 3181 | 739 | 2.51 / 562.36 | 2 | 2 |
5 | 13 | 1755.16 | 30 | 12.25 | 2871 | 1055 | 3.56 / 563.41 | 2 | 2 |
6 | 13 | 981.44 | 30 | 13.03 | 1762 | 689 | 4.25 / 564.10 | 2 | 5 |
7 | 13 | 75.00 | 30 | 14.08 | 450 | 190 | 4.44 / 564.29 | 2 | 8 |
8 | 8 | 0.00 | 190 | 14.06 | 330 | 882 | 5.32 / 565.17 | 2 | 17 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 29 | 14.17 | 470 | 193 | 0.19 / 554.70 | 2 | 2 |
2 | 12 | 1117.64 | 5 | 12.07 | 1953 | 118 | 0.31 / 554.82 | 2 | 2 |
3 | 12 | 2002.08 | 42 | 10.84 | 3191 | 1453 | 1.76 / 556.27 | 2 | 2 |
4 | 7 | 1997.20 | 21 | 11.03 | 3191 | 739 | 2.50 / 557.01 | 2 | 2 |
5 | 13 | 1768.36 | 30 | 12.22 | 2887 | 1058 | 3.56 / 558.07 | 2 | 2 |
6 | 13 | 997.24 | 30 | 13.02 | 1791 | 700 | 4.26 / 558.77 | 2 | 5 |
7 | 13 | 86.32 | 30 | 14.07 | 468 | 198 | 4.46 / 558.97 | 2 | 8 |
8 | 8 | 0.00 | 190 | 14.06 | 331 | 884 | 5.34 / 559.85 | 2 | 19 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 29 | 14.18 | 475 | 195 | 0.20 / 549.39 | 2 | 2 |
2 | 12 | 1117.08 | 5 | 12.12 | 1942 | 118 | 0.31 / 549.50 | 2 | 2 |
3 | 12 | 2001.04 | 42 | 10.82 | 3195 | 1452 | 1.76 / 550.96 | 2 | 2 |
4 | 7 | 1994.84 | 21 | 11.04 | 3191 | 740 | 2.50 / 551.70 | 2 | 2 |
5 | 13 | 1752.96 | 30 | 12.23 | 2859 | 1049 | 3.55 / 552.74 | 2 | 2 |
6 | 13 | 983.00 | 30 | 13.02 | 1772 | 692 | 4.25 / 553.44 | 2 | 5 |
7 | 13 | 83.56 | 30 | 14.07 | 460 | 194 | 4.44 / 553.63 | 2 | 8 |
8 | 8 | 0.24 | 190 | 14.06 | 328 | 876 | 5.32 / 554.51 | 2 | 23 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 30 | 14.16 | 476 | 202 | 0.20 / 544.07 | 2 | 2 |
2 | 3 | 959.36 | -1 | 14.16 | 476 | 0 | 0.00 / 544.07 | 2 | 2 |
3 | 3 | 1019.20 | 1 | 10.86 | 1815 | 20 | 0.22 / 544.09 | 2 | 2 |
4 | 12 | 1136.72 | 5 | 12.06 | 1980 | 119 | 0.34 / 544.21 | 2 | 2 |
5 | 12 | 2001.76 | 42 | 10.84 | 3191 | 1453 | 1.79 / 545.66 | 2 | 2 |
6 | 7 | 1996.60 | 20 | 11.10 | 3192 | 709 | 2.50 / 546.37 | 2 | 2 |
7 | 13 | 1769.56 | 30 | 12.22 | 2889 | 1059 | 3.56 / 547.43 | 2 | 2 |
8 | 13 | 994.68 | 30 | 13.01 | 1790 | 699 | 4.26 / 548.13 | 2 | 5 |
9 | 13 | 48.12 | 30 | 14.12 | 413 | 175 | 4.44 / 548.30 | 2 | 8 |
10 | 8 | -0.04 | 190 | 14.03 | 333 | 888 | 5.32 / 549.19 | 2 | 20 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 30 | 14.14 | 486 | 206 | 0.21 / 538.77 | 2 | 2 |
2 | 12 | 1106.28 | 5 | 12.04 | 1942 | 117 | 0.32 / 538.88 | 2 | 2 |
3 | 12 | 2000.60 | 42 | 10.77 | 3185 | 1441 | 1.76 / 540.32 | 2 | 2 |
4 | 7 | 1996.04 | 21 | 11.04 | 3179 | 737 | 2.50 / 541.06 | 2 | 2 |
5 | 13 | 1755.64 | 30 | 12.20 | 2874 | 1052 | 3.55 / 542.11 | 2 | 2 |
6 | 13 | 993.64 | 30 | 13.00 | 1792 | 699 | 4.25 / 542.81 | 2 | 5 |
7 | 13 | 43.80 | 30 | 14.14 | 405 | 172 | 4.42 / 542.98 | 2 | 8 |
8 | 8 | -0.08 | 190 | 14.03 | 332 | 885 | 5.31 / 543.87 | 2 | 20 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 30 | 14.15 | 478 | 203 | 0.20 / 533.65 | 2 | 2 |
2 | 12 | 1112.32 | 5 | 12.09 | 1943 | 117 | 0.32 / 533.76 | 2 | 2 |
3 | 12 | 2002.60 | 42 | 10.81 | 3187 | 1447 | 1.77 / 535.21 | 2 | 2 |
4 | 7 | 1997.76 | 21 | 11.02 | 3183 | 737 | 2.50 / 535.95 | 2 | 2 |
5 | 13 | 1546.76 | 30 | 12.43 | 2564 | 956 | 3.46 / 536.90 | 2 | 3 |
6 | 13 | 820.44 | 30 | 13.19 | 1539 | 609 | 4.07 / 537.51 | 2 | 6 |
7 | 13 | 31.60 | 30 | 14.15 | 384 | 163 | 4.23 / 537.67 | 2 | 9 |
8 | 8 | 0.16 | 190 | 14.02 | 332 | 884 | 5.12 / 538.56 | 2 | 20 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 30 | 14.13 | 487 | 206 | 0.21 / 528.35 | 2 | 2 |
2 | 12 | 1110.60 | 5 | 12.08 | 1943 | 117 | 0.32 / 528.46 | 2 | 2 |
3 | 12 | 2004.32 | 42 | 10.80 | 3188 | 1446 | 1.77 / 529.91 | 2 | 2 |
4 | 7 | 1999.04 | 21 | 11.02 | 3179 | 736 | 2.51 / 530.65 | 2 | 2 |
5 | 13 | 1758.40 | 30 | 12.21 | 2870 | 1051 | 3.56 / 531.70 | 2 | 2 |
6 | 13 | 988.40 | 30 | 13.01 | 1777 | 694 | 4.25 / 532.39 | 2 | 5 |
7 | 13 | 78.72 | 30 | 14.08 | 446 | 188 | 4.44 / 532.58 | 2 | 8 |
8 | 8 | 0.04 | 190 | 14.06 | 323 | 863 | 5.30 / 533.44 | 2 | 19 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 28 | 14.13 | 498 | 197 | 0.20 / 523.19 | 2 | 2 |
2 | 3 | 1051.24 | 1 | 12.58 | 1882 | 24 | 0.22 / 523.21 | 2 | 2 |
3 | 12 | 1137.48 | 5 | 11.98 | 1990 | 119 | 0.34 / 523.33 | 2 | 2 |
4 | 12 | 2004.28 | 42 | 10.85 | 3191 | 1454 | 1.79 / 524.78 | 2 | 2 |
5 | 7 | 1999.72 | 21 | 11.04 | 3202 | 742 | 2.54 / 525.53 | 2 | 2 |
6 | 13 | 1542.12 | 30 | 12.43 | 2572 | 959 | 3.50 / 526.49 | 2 | 3 |
7 | 13 | 818.48 | 30 | 13.19 | 1548 | 613 | 4.11 / 527.10 | 2 | 6 |
8 | 13 | 29.04 | 30 | 14.16 | 377 | 160 | 4.27 / 527.26 | 2 | 8 |
9 | 8 | 0.16 | 190 | 14.02 | 331 | 882 | 5.15 / 528.14 | 2 | 22 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 28 | 14.13 | 489 | 193 | 0.19 / 517.96 | 2 | 3 |
2 | 12 | 1118.52 | 5 | 12.12 | 1961 | 119 | 0.31 / 518.08 | 2 | 2 |
3 | 12 | 2001.44 | 42 | 10.86 | 3191 | 1455 | 1.77 / 519.54 | 2 | 2 |
4 | 7 | 1995.48 | 21 | 11.05 | 3183 | 739 | 2.51 / 520.28 | 2 | 2 |
5 | 13 | 1537.52 | 30 | 12.41 | 2564 | 955 | 3.46 / 521.23 | 2 | 3 |
6 | 13 | 1017.36 | 30 | 12.97 | 1816 | 707 | 4.17 / 521.94 | 2 | 5 |
7 | 13 | 46.96 | 30 | 14.13 | 405 | 172 | 4.34 / 522.11 | 2 | 8 |
8 | 8 | -0.08 | 190 | 14.02 | 331 | 882 | 5.22 / 522.99 | 2 | 22 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 28 | 14.14 | 496 | 196 | 0.20 / 512.95 | 2 | 3 |
2 | 12 | 1134.48 | 5 | 12.13 | 1965 | 119 | 0.32 / 513.07 | 2 | 2 |
3 | 12 | 2002.08 | 42 | 10.83 | 3193 | 1452 | 1.77 / 514.52 | 2 | 2 |
4 | 7 | 1996.96 | 21 | 11.01 | 3191 | 738 | 2.51 / 515.26 | 2 | 2 |
5 | 13 | 1766.04 | 30 | 12.18 | 2877 | 1051 | 3.56 / 516.31 | 2 | 3 |
6 | 13 | 766.68 | 30 | 13.23 | 1463 | 581 | 4.14 / 516.89 | 2 | 6 |
7 | 8 | 0.24 | 190 | 14.05 | 328 | 876 | 5.01 / 517.77 | 2 | 17 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 28 | 14.15 | 483 | 191 | 0.19 / 507.89 | 2 | 3 |
2 | 12 | 1114.88 | 4 | 12.06 | 1952 | 94 | 0.29 / 507.99 | 2 | 2 |
3 | 7 | 2001.28 | 52 | 10.72 | 3186 | 1776 | 2.06 / 509.76 | 2 | 2 |
4 | 13 | 1791.28 | 32 | 12.09 | 2921 | 1130 | 3.19 / 510.89 | 2 | 2 |
5 | 13 | 1073.08 | 32 | 12.92 | 1867 | 772 | 3.96 / 511.67 | 2 | 4 |
6 | 13 | 70.16 | 32 | 14.10 | 441 | 199 | 4.16 / 511.87 | 2 | 8 |
7 | 8 | 0.04 | 190 | 14.04 | 334 | 891 | 5.05 / 512.76 | 2 | 31 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 28 | 14.16 | 481 | 191 | 0.19 / 502.85 | 2 | 3 |
2 | 12 | 1117.36 | 4 | 11.98 | 1956 | 94 | 0.28 / 502.95 | 2 | 2 |
3 | 7 | 2004.80 | 52 | 10.73 | 3192 | 1781 | 2.07 / 504.73 | 2 | 2 |
4 | 13 | 1793.40 | 32 | 12.10 | 2926 | 1133 | 3.20 / 505.86 | 2 | 2 |
5 | 13 | 1063.88 | 32 | 12.92 | 1868 | 772 | 3.97 / 506.63 | 2 | 4 |
6 | 13 | 67.56 | 32 | 14.10 | 434 | 196 | 4.17 / 506.83 | 2 | 8 |
7 | 8 | 0.20 | 190 | 14.05 | 328 | 876 | 5.04 / 507.70 | 2 | 16 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 28 | 14.13 | 490 | 194 | 0.19 / 497.83 | 2 | 3 |
2 | 12 | 1123.84 | 4 | 12.06 | 1970 | 95 | 0.29 / 497.93 | 2 | 2 |
3 | 7 | 2001.60 | 52 | 10.73 | 3192 | 1781 | 2.07 / 499.71 | 2 | 2 |
4 | 13 | 1787.80 | 32 | 12.09 | 2915 | 1128 | 3.20 / 500.84 | 2 | 2 |
5 | 13 | 1059.16 | 32 | 12.91 | 1867 | 771 | 3.97 / 501.61 | 2 | 5 |
6 | 13 | 72.40 | 32 | 14.10 | 433 | 195 | 4.16 / 501.80 | 2 | 8 |
7 | 8 | 0.20 | 190 | 14.06 | 321 | 858 | 5.02 / 502.66 | 2 | 18 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 28 | 14.16 | 488 | 193 | 0.19 / 492.62 | 2 | 3 |
2 | 12 | 1119.84 | 4 | 11.97 | 1955 | 94 | 0.29 / 492.71 | 2 | 2 |
3 | 7 | 2003.96 | 52 | 10.71 | 3186 | 1774 | 2.06 / 494.49 | 2 | 2 |
4 | 13 | 1785.24 | 32 | 12.11 | 2907 | 1127 | 3.19 / 495.61 | 2 | 2 |
5 | 13 | 1062.84 | 32 | 12.91 | 1873 | 774 | 3.96 / 496.39 | 2 | 5 |
6 | 13 | 138.04 | 32 | 14.00 | 539 | 241 | 4.20 / 496.63 | 2 | 8 |
7 | 13 | 3.52 | 32 | 14.20 | 334 | 152 | 4.35 / 496.78 | 2 | 8 |
8 | 8 | -0.16 | 190 | 13.98 | 323 | 858 | 5.21 / 497.64 | 2 | 25 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 28 | 14.18 | 480 | 191 | 0.19 / 487.77 | 2 | 3 |
2 | 12 | 1123.96 | 4 | 12.04 | 1964 | 95 | 0.29 / 487.86 | 2 | 2 |
3 | 7 | 2002.48 | 52 | 10.77 | 3195 | 1789 | 2.07 / 489.65 | 2 | 2 |
4 | 13 | 1593.24 | 32 | 12.31 | 2639 | 1040 | 3.11 / 490.69 | 2 | 3 |
5 | 13 | 903.60 | 32 | 13.08 | 1657 | 694 | 3.81 / 491.39 | 2 | 6 |
6 | 13 | 40.56 | 32 | 14.15 | 389 | 176 | 3.98 / 491.56 | 2 | 8 |
7 | 8 | 0.56 | 190 | 14.00 | 325 | 864 | 4.85 / 492.43 | 2 | 18 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 28 | 14.16 | 479 | 190 | 0.19 / 482.70 | 2 | 3 |
2 | 12 | 1124.68 | 4 | 12.01 | 1970 | 95 | 0.28 / 482.79 | 2 | 2 |
3 | 7 | 2005.20 | 53 | 10.77 | 3190 | 1821 | 2.11 / 484.61 | 2 | 2 |
4 | 13 | 1794.52 | 32 | 12.12 | 2912 | 1129 | 3.23 / 485.74 | 2 | 2 |
5 | 13 | 1067.32 | 32 | 12.91 | 1888 | 780 | 4.01 / 486.52 | 2 | 5 |
6 | 13 | 63.00 | 32 | 14.12 | 421 | 190 | 4.21 / 486.71 | 2 | 8 |
7 | 8 | -0.08 | 190 | 14.03 | 324 | 864 | 5.07 / 487.58 | 2 | 16 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 28 | 14.14 | 493 | 195 | 0.20 / 477.67 | 2 | 3 |
2 | 12 | 1115.40 | 4 | 12.00 | 1954 | 94 | 0.29 / 477.76 | 2 | 2 |
3 | 7 | 2002.52 | 52 | 10.81 | 3182 | 1789 | 2.08 / 479.55 | 2 | 2 |
4 | 13 | 1785.88 | 32 | 12.11 | 2917 | 1130 | 3.21 / 480.68 | 2 | 2 |
5 | 13 | 1049.12 | 32 | 12.91 | 1872 | 773 | 3.98 / 481.45 | 2 | 5 |
6 | 13 | 67.72 | 32 | 14.11 | 430 | 194 | 4.18 / 481.65 | 2 | 8 |
7 | 8 | -0.08 | 190 | 14.03 | 323 | 861 | 5.04 / 482.51 | 2 | 18 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 27 | 14.18 | 490 | 188 | 0.19 / 472.67 | 2 | 3 |
2 | 12 | 1133.28 | 4 | 12.00 | 1976 | 95 | 0.28 / 472.77 | 2 | 2 |
3 | 7 | 2007.08 | 53 | 10.81 | 3193 | 1829 | 2.11 / 474.60 | 2 | 2 |
4 | 13 | 1790.60 | 32 | 12.13 | 2918 | 1133 | 3.24 / 475.73 | 2 | 3 |
5 | 13 | 838.56 | 32 | 13.16 | 1566 | 659 | 3.90 / 476.39 | 2 | 6 |
6 | 13 | 75.20 | 32 | 14.11 | 447 | 202 | 4.11 / 476.59 | 2 | 8 |
7 | 8 | 0.16 | 190 | 14.04 | 330 | 880 | 4.99 / 477.47 | 2 | 17 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 28 | 14.19 | 488 | 194 | 0.19 / 467.70 | 2 | 2 |
2 | 3 | 967.12 | -1 | 14.19 | 488 | 0 | 0.00 / 467.70 | 2 | 2 |
3 | 12 | 1150.68 | 4 | 11.97 | 2006 | 96 | 0.29 / 467.80 | 2 | 2 |
4 | 7 | 2005.84 | 53 | 10.82 | 3192 | 1830 | 2.12 / 469.63 | 2 | 2 |
5 | 13 | 1788.28 | 32 | 12.14 | 2914 | 1132 | 3.25 / 470.76 | 2 | 3 |
6 | 13 | 850.96 | 32 | 13.16 | 1585 | 667 | 3.92 / 471.43 | 2 | 6 |
7 | 13 | 37.64 | 32 | 14.18 | 386 | 175 | 4.10 / 471.60 | 2 | 8 |
8 | 8 | -0.12 | 190 | 14.03 | 331 | 882 | 4.98 / 472.49 | 2 | 18 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 29 | 14.19 | 497 | 205 | 0.20 / 462.61 | 2 | 3 |
2 | 3 | 963.92 | -1 | 14.19 | 497 | 0 | 0.00 / 462.61 | 2 | 3 |
3 | 3 | 1022.88 | 1 | 11.46 | 1829 | 21 | 0.23 / 462.63 | 2 | 2 |
4 | 12 | 1132.20 | 4 | 11.94 | 1983 | 95 | 0.32 / 462.72 | 2 | 2 |
5 | 7 | 2005.52 | 52 | 10.85 | 3196 | 1803 | 2.12 / 464.52 | 2 | 2 |
6 | 13 | 1801.20 | 32 | 12.16 | 2930 | 1140 | 3.26 / 465.66 | 2 | 3 |
7 | 13 | 1069.16 | 32 | 12.94 | 1889 | 782 | 4.05 / 466.45 | 2 | 5 |
8 | 13 | 59.48 | 32 | 14.14 | 417 | 189 | 4.23 / 466.63 | 2 | 8 |
9 | 8 | 0.40 | 190 | 14.03 | 328 | 874 | 5.11 / 467.51 | 2 | 18 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 28 | 14.20 | 493 | 196 | 0.20 / 457.44 | 2 | 3 |
2 | 3 | 1035.36 | 1 | 12.57 | 1859 | 23 | 0.22 / 457.46 | 2 | 2 |
3 | 12 | 1132.68 | 4 | 11.89 | 1968 | 94 | 0.31 / 457.55 | 2 | 2 |
4 | 7 | 2004.56 | 52 | 10.89 | 3185 | 1804 | 2.12 / 459.36 | 2 | 2 |
5 | 13 | 1797.56 | 32 | 12.19 | 2914 | 1137 | 3.25 / 460.49 | 2 | 2 |
6 | 13 | 1074.40 | 32 | 12.96 | 1886 | 782 | 4.04 / 461.28 | 2 | 4 |
7 | 13 | 138.92 | 32 | 14.03 | 541 | 243 | 4.28 / 461.52 | 2 | 8 |
8 | 8 | 0.04 | 190 | 14.06 | 330 | 882 | 5.16 / 462.40 | 2 | 21 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 28 | 14.22 | 482 | 192 | 0.19 / 452.36 | 2 | 2 |
2 | 12 | 1141.00 | 4 | 11.91 | 1994 | 95 | 0.29 / 452.46 | 2 | 2 |
3 | 7 | 2002.52 | 52 | 10.85 | 3190 | 1800 | 2.09 / 454.26 | 2 | 2 |
4 | 13 | 1790.24 | 32 | 12.16 | 2911 | 1133 | 3.22 / 455.39 | 2 | 2 |
5 | 13 | 1076.40 | 32 | 12.95 | 1893 | 784 | 4.00 / 456.17 | 2 | 5 |
6 | 13 | 68.96 | 32 | 14.14 | 434 | 196 | 4.20 / 456.37 | 2 | 8 |
7 | 8 | 0.08 | 190 | 14.04 | 326 | 870 | 5.07 / 457.24 | 2 | 21 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 28 | 14.24 | 475 | 189 | 0.19 / 447.23 | 2 | 2 |
2 | 3 | 973.16 | -1 | 14.24 | 475 | 0 | 0.00 / 447.23 | 2 | 2 |
3 | 3 | 1037.36 | 1 | 12.33 | 1854 | 23 | 0.21 / 447.26 | 2 | 2 |
4 | 12 | 1133.32 | 4 | 11.91 | 1979 | 94 | 0.31 / 447.35 | 2 | 2 |
5 | 7 | 2001.40 | 53 | 10.91 | 3189 | 1844 | 2.15 / 449.19 | 2 | 2 |
6 | 13 | 1783.32 | 32 | 12.20 | 2904 | 1134 | 3.28 / 450.33 | 2 | 2 |
7 | 13 | 1034.24 | 32 | 13.01 | 1825 | 760 | 4.04 / 451.09 | 2 | 5 |
8 | 13 | 109.04 | 32 | 14.07 | 496 | 223 | 4.27 / 451.31 | 2 | 8 |
9 | 8 | 0.00 | 190 | 14.06 | 322 | 860 | 5.13 / 452.17 | 2 | 17 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 28 | 14.22 | 491 | 195 | 0.20 / 442.12 | 2 | 2 |
2 | 12 | 1127.16 | 4 | 11.88 | 1981 | 94 | 0.29 / 442.22 | 2 | 2 |
3 | 7 | 2004.36 | 53 | 10.91 | 3190 | 1845 | 2.13 / 444.06 | 2 | 2 |
4 | 13 | 1788.72 | 32 | 12.21 | 2915 | 1139 | 3.27 / 445.20 | 2 | 3 |
5 | 13 | 1055.32 | 32 | 12.97 | 1864 | 774 | 4.05 / 445.97 | 2 | 5 |
6 | 13 | 67.08 | 32 | 14.14 | 433 | 196 | 4.24 / 446.17 | 2 | 8 |
7 | 8 | 0.24 | 190 | 14.04 | 328 | 875 | 5.12 / 447.04 | 2 | 21 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 28 | 14.25 | 471 | 188 | 0.19 / 437.05 | 2 | 3 |
2 | 12 | 1129.60 | 4 | 12.00 | 1975 | 95 | 0.28 / 437.14 | 2 | 2 |
3 | 7 | 2003.44 | 52 | 10.94 | 3187 | 1813 | 2.10 / 438.95 | 2 | 2 |
4 | 13 | 1786.04 | 32 | 12.21 | 2901 | 1133 | 3.23 / 440.09 | 2 | 3 |
5 | 13 | 1047.60 | 32 | 13.00 | 1842 | 766 | 4.00 / 440.85 | 2 | 5 |
6 | 13 | 67.12 | 32 | 14.15 | 431 | 195 | 4.19 / 441.05 | 2 | 8 |
7 | 8 | -0.12 | 190 | 14.04 | 329 | 878 | 5.07 / 441.93 | 2 | 18 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 28 | 14.25 | 481 | 192 | 0.19 / 431.97 | 2 | 2 |
2 | 12 | 1116.24 | 4 | 11.99 | 1943 | 93 | 0.29 / 432.07 | 2 | 2 |
3 | 7 | 2006.20 | 52 | 10.95 | 3197 | 1820 | 2.11 / 433.89 | 2 | 2 |
4 | 13 | 1802.88 | 32 | 12.22 | 2933 | 1147 | 3.25 / 435.03 | 2 | 3 |
5 | 13 | 1065.88 | 32 | 12.98 | 1876 | 779 | 4.03 / 435.81 | 2 | 5 |
6 | 13 | 68.08 | 32 | 14.15 | 428 | 194 | 4.23 / 436.01 | 2 | 8 |
7 | 8 | 0.24 | 190 | 14.05 | 319 | 852 | 5.08 / 436.86 | 2 | 20 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 28 | 14.27 | 479 | 191 | 0.19 / 426.84 | 2 | 2 |
2 | 12 | 1129.08 | 4 | 11.93 | 1962 | 94 | 0.29 / 426.94 | 2 | 2 |
3 | 7 | 2002.12 | 53 | 11.02 | 3187 | 1861 | 2.15 / 428.80 | 2 | 2 |
4 | 13 | 1785.12 | 32 | 12.27 | 2895 | 1137 | 3.28 / 429.93 | 2 | 3 |
5 | 13 | 1043.08 | 32 | 13.01 | 1857 | 773 | 4.06 / 430.71 | 2 | 5 |
6 | 13 | 56.32 | 32 | 14.17 | 420 | 190 | 4.25 / 430.90 | 2 | 8 |
7 | 8 | 0.04 | 190 | 14.04 | 331 | 883 | 5.13 / 431.78 | 2 | 17 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 28 | 14.30 | 464 | 186 | 0.19 / 421.81 | 2 | 2 |
2 | 3 | 970.28 | -1 | 14.30 | 464 | 0 | 0.00 / 421.81 | 2 | 2 |
3 | 3 | 1036.32 | 1 | 12.52 | 1849 | 23 | 0.21 / 421.83 | 2 | 2 |
4 | 12 | 1141.20 | 4 | 11.88 | 1991 | 95 | 0.30 / 421.92 | 2 | 2 |
5 | 7 | 2003.68 | 52 | 10.99 | 3194 | 1825 | 2.13 / 423.75 | 2 | 2 |
6 | 13 | 1794.68 | 32 | 12.26 | 2916 | 1144 | 3.27 / 424.89 | 2 | 3 |
7 | 13 | 876.36 | 32 | 13.19 | 1622 | 685 | 3.96 / 425.58 | 2 | 6 |
8 | 13 | 81.52 | 32 | 14.14 | 450 | 204 | 4.16 / 425.78 | 2 | 8 |
9 | 8 | 0.12 | 190 | 14.09 | 325 | 870 | 5.03 / 426.65 | 2 | 19 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 28 | 14.28 | 475 | 190 | 0.19 / 416.86 | 2 | 2 |
2 | 12 | 1115.28 | 4 | 11.82 | 1953 | 92 | 0.28 / 416.95 | 2 | 2 |
3 | 7 | 2002.36 | 53 | 11.04 | 3195 | 1869 | 2.15 / 418.82 | 2 | 2 |
4 | 13 | 1593.24 | 32 | 12.47 | 2649 | 1057 | 3.21 / 419.88 | 2 | 3 |
5 | 13 | 892.68 | 32 | 13.19 | 1645 | 694 | 3.90 / 420.57 | 2 | 6 |
6 | 13 | 76.56 | 32 | 14.16 | 444 | 201 | 4.10 / 420.77 | 2 | 8 |
7 | 8 | -0.04 | 190 | 14.07 | 317 | 847 | 4.95 / 421.62 | 2 | 19 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 28 | 14.30 | 470 | 188 | 0.19 / 411.84 | 2 | 2 |
2 | 12 | 1120.92 | 4 | 12.02 | 1947 | 94 | 0.28 / 411.93 | 2 | 2 |
3 | 7 | 2002.96 | 52 | 11.07 | 3188 | 1835 | 2.12 / 413.76 | 2 | 2 |
4 | 13 | 1795.20 | 32 | 12.29 | 2912 | 1145 | 3.26 / 414.91 | 2 | 3 |
5 | 13 | 861.60 | 32 | 13.22 | 1604 | 679 | 3.94 / 415.59 | 2 | 6 |
6 | 13 | 74.52 | 32 | 14.15 | 447 | 202 | 4.14 / 415.79 | 2 | 8 |
7 | 8 | -0.08 | 190 | 14.04 | 329 | 878 | 5.02 / 416.67 | 2 | 17 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 28 | 14.30 | 468 | 187 | 0.19 / 406.86 | 2 | 2 |
2 | 12 | 1108.88 | 4 | 11.63 | 1939 | 90 | 0.28 / 406.95 | 2 | 2 |
3 | 7 | 2001.32 | 52 | 11.01 | 3180 | 1821 | 2.10 / 408.77 | 2 | 2 |
4 | 13 | 1786.88 | 32 | 12.30 | 2907 | 1144 | 3.24 / 409.92 | 2 | 3 |
5 | 13 | 848.72 | 32 | 13.25 | 1584 | 672 | 3.91 / 410.59 | 2 | 6 |
6 | 13 | 39.16 | 32 | 14.22 | 393 | 179 | 4.09 / 410.77 | 2 | 8 |
7 | 8 | 0.16 | 190 | 14.05 | 330 | 881 | 4.97 / 411.65 | 2 | 18 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 28 | 14.33 | 474 | 190 | 0.19 / 401.73 | 2 | 2 |
2 | 12 | 1126.52 | 4 | 11.65 | 1950 | 91 | 0.28 / 401.82 | 2 | 2 |
3 | 7 | 2002.52 | 52 | 11.00 | 3183 | 1821 | 2.10 / 403.64 | 2 | 2 |
4 | 13 | 1785.96 | 32 | 12.33 | 2912 | 1149 | 3.25 / 404.79 | 2 | 3 |
5 | 13 | 1041.60 | 32 | 13.07 | 1842 | 770 | 4.02 / 405.56 | 2 | 5 |
6 | 13 | 117.56 | 32 | 14.10 | 515 | 232 | 4.25 / 405.80 | 2 | 8 |
7 | 8 | -0.04 | 190 | 14.08 | 328 | 877 | 5.13 / 406.67 | 2 | 21 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 28 | 14.32 | 471 | 189 | 0.19 / 396.64 | 2 | 2 |
2 | 12 | 1117.92 | 4 | 11.80 | 1955 | 92 | 0.28 / 396.73 | 2 | 2 |
3 | 7 | 2004.72 | 52 | 10.99 | 3189 | 1822 | 2.10 / 398.55 | 2 | 2 |
4 | 13 | 1795.56 | 32 | 12.32 | 2929 | 1155 | 3.26 / 399.71 | 2 | 3 |
5 | 13 | 1055.00 | 32 | 13.07 | 1859 | 778 | 4.04 / 400.48 | 2 | 5 |
6 | 13 | 34.00 | 32 | 14.23 | 387 | 176 | 4.21 / 400.66 | 2 | 8 |
7 | 8 | 0.16 | 190 | 14.04 | 331 | 883 | 5.10 / 401.54 | 2 | 15 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 28 | 14.37 | 467 | 188 | 0.19 / 391.70 | 2 | 2 |
2 | 12 | 1129.52 | 4 | 12.20 | 1970 | 96 | 0.28 / 391.79 | 2 | 2 |
3 | 7 | 2004.76 | 52 | 11.15 | 3191 | 1850 | 2.13 / 393.64 | 2 | 2 |
4 | 13 | 1583.64 | 32 | 12.54 | 2604 | 1045 | 3.18 / 394.69 | 2 | 3 |
5 | 13 | 889.32 | 32 | 13.23 | 1634 | 692 | 3.87 / 395.38 | 2 | 6 |
6 | 13 | 70.60 | 32 | 14.19 | 440 | 200 | 4.07 / 395.58 | 2 | 8 |
7 | 8 | -0.04 | 190 | 14.06 | 325 | 868 | 4.94 / 396.45 | 2 | 21 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 28 | 14.37 | 467 | 188 | 0.19 / 386.78 | 2 | 2 |
2 | 7 | 2004.96 | 83 | 10.82 | 3176 | 2852 | 3.04 / 389.63 | 2 | 2 |
3 | 13 | 1077.80 | 32 | 13.08 | 1903 | 797 | 3.84 / 390.43 | 2 | 5 |
4 | 13 | 89.40 | 32 | 14.19 | 469 | 213 | 4.05 / 390.64 | 2 | 7 |
5 | 8 | 0.00 | 190 | 14.13 | 323 | 867 | 4.92 / 391.51 | 2 | 16 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 28 | 14.37 | 469 | 189 | 0.19 / 381.95 | 2 | 2 |
2 | 7 | 2002.12 | 46 | 10.93 | 3166 | 1592 | 1.78 / 383.54 | 2 | 2 |
3 | 13 | 1812.24 | 32 | 12.42 | 2945 | 1170 | 2.95 / 384.71 | 2 | 3 |
4 | 13 | 1120.08 | 32 | 13.07 | 1954 | 817 | 3.77 / 385.53 | 2 | 5 |
5 | 13 | 79.60 | 32 | 14.20 | 448 | 204 | 3.97 / 385.73 | 2 | 8 |
6 | 8 | 0.12 | 190 | 14.12 | 320 | 858 | 4.83 / 386.59 | 2 | 28 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 29 | 14.34 | 478 | 199 | 0.20 / 377.17 | 2 | 2 |
2 | 3 | 943.76 | -1 | 14.34 | 478 | 0 | 0.00 / 377.17 | 2 | 2 |
3 | 7 | 2007.56 | 47 | 10.82 | 3193 | 1624 | 1.82 / 378.80 | 2 | 2 |
4 | 13 | 1817.00 | 32 | 12.43 | 2963 | 1179 | 3.00 / 379.98 | 2 | 3 |
5 | 13 | 944.12 | 32 | 13.24 | 1725 | 731 | 3.73 / 380.71 | 2 | 5 |
6 | 13 | 48.52 | 32 | 14.25 | 403 | 184 | 3.92 / 380.89 | 2 | 7 |
7 | 8 | 0.00 | 190 | 14.09 | 325 | 870 | 4.79 / 381.76 | 2 | 18 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 28 | 14.35 | 484 | 194 | 0.19 / 372.34 | 2 | 2 |
2 | 3 | 1036.76 | 1 | 13.14 | 1874 | 25 | 0.22 / 372.37 | 2 | 2 |
3 | 3 | 1021.32 | 1 | 12.91 | 1855 | 24 | 0.24 / 372.39 | 2 | 2 |
4 | 7 | 2008.08 | 46 | 10.90 | 3168 | 1588 | 1.83 / 373.98 | 2 | 2 |
5 | 13 | 1816.00 | 32 | 12.44 | 2963 | 1180 | 3.01 / 375.16 | 2 | 3 |
6 | 13 | 946.68 | 32 | 13.24 | 1733 | 734 | 3.75 / 375.89 | 2 | 5 |
7 | 13 | 52.56 | 32 | 14.24 | 417 | 190 | 3.94 / 376.08 | 2 | 7 |
8 | 8 | 0.08 | 190 | 14.08 | 334 | 894 | 4.83 / 376.98 | 2 | 20 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 28 | 14.36 | 479 | 193 | 0.19 / 367.63 | 2 | 2 |
2 | 7 | 2003.88 | 46 | 10.76 | 3188 | 1578 | 1.77 / 369.21 | 2 | 2 |
3 | 13 | 1811.72 | 32 | 12.46 | 2947 | 1175 | 2.95 / 370.39 | 2 | 3 |
4 | 13 | 935.92 | 32 | 13.26 | 1710 | 726 | 3.67 / 371.11 | 2 | 5 |
5 | 13 | 27.16 | 32 | 14.28 | 370 | 169 | 3.84 / 371.28 | 2 | 7 |
6 | 8 | 0.12 | 190 | 14.08 | 324 | 867 | 4.71 / 372.15 | 2 | 18 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 28 | 14.36 | 478 | 192 | 0.19 / 362.79 | 2 | 2 |
2 | 7 | 2007.88 | 46 | 10.85 | 3172 | 1583 | 1.78 / 364.38 | 2 | 2 |
3 | 13 | 1809.92 | 32 | 12.45 | 2941 | 1172 | 2.95 / 365.55 | 2 | 3 |
4 | 13 | 1122.84 | 32 | 13.09 | 1966 | 824 | 3.77 / 366.37 | 2 | 5 |
5 | 13 | 46.20 | 32 | 14.26 | 402 | 183 | 3.95 / 366.55 | 2 | 8 |
6 | 8 | 0.12 | 190 | 14.08 | 331 | 885 | 4.84 / 367.44 | 2 | 20 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 27 | 14.33 | 488 | 189 | 0.19 / 357.99 | 2 | 3 |
2 | 7 | 2007.76 | 47 | 10.90 | 3179 | 1629 | 1.82 / 359.62 | 2 | 2 |
3 | 13 | 1812.36 | 32 | 12.48 | 2949 | 1178 | 3.00 / 360.80 | 2 | 3 |
4 | 13 | 937.36 | 32 | 13.28 | 1714 | 728 | 3.72 / 361.53 | 2 | 6 |
5 | 13 | 47.84 | 32 | 14.26 | 409 | 187 | 3.91 / 361.71 | 2 | 8 |
6 | 8 | 0.00 | 190 | 14.08 | 332 | 888 | 4.80 / 362.60 | 2 | 23 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 27 | 14.34 | 481 | 186 | 0.19 / 353.24 | 2 | 2 |
2 | 7 | 2003.76 | 46 | 10.92 | 3170 | 1592 | 1.78 / 354.83 | 2 | 2 |
3 | 13 | 1820.20 | 32 | 12.48 | 2959 | 1182 | 2.96 / 356.02 | 2 | 3 |
4 | 13 | 942.24 | 32 | 13.27 | 1719 | 730 | 3.69 / 356.75 | 2 | 6 |
5 | 13 | 44.80 | 32 | 14.27 | 397 | 181 | 3.87 / 356.93 | 2 | 8 |
6 | 8 | -0.04 | 190 | 14.08 | 327 | 875 | 4.75 / 357.80 | 2 | 22 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 27 | 14.34 | 491 | 190 | 0.19 / 348.52 | 2 | 3 |
2 | 7 | 2003.44 | 46 | 10.93 | 3180 | 1599 | 1.79 / 350.11 | 2 | 2 |
3 | 13 | 1810.52 | 32 | 12.50 | 2928 | 1171 | 2.96 / 351.29 | 2 | 3 |
4 | 13 | 937.48 | 32 | 13.29 | 1708 | 726 | 3.69 / 352.01 | 2 | 6 |
5 | 13 | 23.36 | 32 | 14.31 | 362 | 166 | 3.85 / 352.18 | 2 | 8 |
6 | 8 | 0.20 | 190 | 14.08 | 328 | 877 | 4.73 / 353.06 | 2 | 18 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 29 | 14.35 | 477 | 199 | 0.20 / 343.76 | 2 | 3 |
2 | 3 | 920.28 | -2 | 14.35 | 477 | 0 | 0.00 / 343.76 | 2 | 3 |
3 | 3 | 1038.48 | 1 | 13.17 | 1882 | 25 | 0.22 / 343.78 | 2 | 2 |
4 | 7 | 2003.84 | 46 | 11.00 | 3184 | 1611 | 1.83 / 345.39 | 2 | 2 |
5 | 13 | 1808.08 | 32 | 12.50 | 2944 | 1178 | 3.01 / 346.57 | 2 | 3 |
6 | 13 | 926.00 | 32 | 13.31 | 1694 | 722 | 3.73 / 347.29 | 2 | 6 |
7 | 13 | 20.04 | 32 | 14.31 | 357 | 163 | 3.90 / 347.45 | 2 | 8 |
8 | 8 | 0.00 | 190 | 14.08 | 326 | 872 | 4.77 / 348.33 | 2 | 18 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 27 | 14.35 | 490 | 190 | 0.19 / 338.92 | 2 | 3 |
2 | 3 | 1054.96 | 1 | 13.44 | 1903 | 26 | 0.22 / 338.95 | 2 | 2 |
3 | 7 | 2003.52 | 46 | 11.01 | 3186 | 1614 | 1.83 / 340.56 | 2 | 2 |
4 | 13 | 1806.40 | 32 | 12.49 | 2944 | 1177 | 3.01 / 341.74 | 2 | 3 |
5 | 13 | 940.72 | 32 | 13.29 | 1718 | 731 | 3.74 / 342.47 | 2 | 6 |
6 | 13 | 92.20 | 32 | 14.21 | 472 | 215 | 3.95 / 342.68 | 2 | 8 |
7 | 8 | 0.04 | 190 | 14.10 | 327 | 876 | 4.83 / 343.56 | 2 | 21 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 28 | 14.36 | 485 | 195 | 0.20 / 334.29 | 2 | 3 |
2 | 3 | 970.56 | -1 | 14.36 | 485 | 0 | 0.00 / 334.29 | 2 | 3 |
3 | 3 | 1028.00 | 1 | 13.00 | 1861 | 24 | 0.22 / 334.32 | 2 | 2 |
4 | 7 | 2002.96 | 46 | 11.06 | 3193 | 1624 | 1.84 / 335.94 | 2 | 2 |
5 | 13 | 1811.80 | 32 | 12.51 | 2955 | 1183 | 3.03 / 337.12 | 2 | 3 |
6 | 13 | 937.04 | 32 | 13.30 | 1715 | 730 | 3.76 / 337.85 | 2 | 6 |
7 | 8 | 0.04 | 190 | 14.13 | 326 | 875 | 4.63 / 338.73 | 2 | 17 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 28 | 14.37 | 494 | 199 | 0.20 / 329.54 | 2 | 3 |
2 | 7 | 2007.80 | 46 | 11.12 | 3201 | 1637 | 1.84 / 331.18 | 3 | 2 |
3 | 13 | 1813.12 | 32 | 12.51 | 2950 | 1181 | 3.02 / 332.36 | 2 | 3 |
4 | 13 | 913.88 | 32 | 13.32 | 1685 | 718 | 3.74 / 333.08 | 2 | 6 |
5 | 13 | 2.96 | 32 | 14.34 | 332 | 152 | 3.89 / 333.23 | 2 | 4 |
6 | 8 | 0.00 | 190 | 14.08 | 324 | 867 | 4.75 / 334.10 | 2 | 14 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 28 | 14.37 | 490 | 197 | 0.20 / 324.91 | 2 | 3 |
2 | 7 | 2005.68 | 47 | 11.11 | 3212 | 1677 | 1.87 / 326.59 | 3 | 2 |
3 | 13 | 1627.80 | 32 | 12.72 | 2665 | 1085 | 2.96 / 327.68 | 2 | 3 |
4 | 13 | 785.20 | 32 | 13.48 | 1493 | 644 | 3.60 / 328.32 | 2 | 6 |
5 | 13 | 12.92 | 32 | 14.32 | 346 | 159 | 3.76 / 328.48 | 2 | 8 |
6 | 8 | 0.12 | 190 | 14.06 | 324 | 866 | 4.63 / 329.34 | 2 | 19 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 28 | 14.36 | 490 | 197 | 0.20 / 320.23 | 2 | 2 |
2 | 7 | 2003.64 | 47 | 11.27 | 3196 | 1693 | 1.89 / 321.92 | 2 | 2 |
3 | 13 | 1804.76 | 32 | 12.53 | 2934 | 1176 | 3.07 / 323.10 | 2 | 3 |
4 | 13 | 923.08 | 32 | 13.33 | 1699 | 725 | 3.79 / 323.82 | 2 | 6 |
5 | 8 | 0.20 | 190 | 14.12 | 334 | 896 | 4.69 / 324.72 | 2 | 17 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 28 | 14.36 | 496 | 199 | 0.20 / 315.63 | 2 | 3 |
2 | 7 | 2002.40 | 46 | 11.34 | 3194 | 1666 | 1.87 / 317.30 | 3 | 2 |
3 | 13 | 1623.36 | 32 | 12.72 | 2680 | 1091 | 2.96 / 318.39 | 2 | 3 |
4 | 13 | 957.08 | 32 | 13.32 | 1739 | 741 | 3.70 / 319.13 | 2 | 6 |
5 | 8 | 0.36 | 190 | 14.12 | 335 | 899 | 4.60 / 320.03 | 2 | 18 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 27 | 14.35 | 504 | 195 | 0.20 / 310.85 | 2 | 3 |
2 | 7 | 2004.20 | 46 | 11.43 | 3201 | 1683 | 1.88 / 312.54 | 2 | 2 |
3 | 13 | 1625.36 | 32 | 12.76 | 2674 | 1092 | 2.97 / 313.63 | 2 | 3 |
4 | 13 | 960.80 | 32 | 13.34 | 1744 | 744 | 3.71 / 314.37 | 2 | 6 |
5 | 13 | 19.36 | 32 | 14.31 | 365 | 167 | 3.88 / 314.54 | 2 | 8 |
6 | 8 | -0.20 | 190 | 14.04 | 335 | 894 | 4.78 / 315.43 | 2 | 19 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 27 | 14.38 | 491 | 191 | 0.19 / 306.25 | 2 | 3 |
2 | 7 | 2007.60 | 46 | 11.47 | 3204 | 1690 | 1.88 / 307.94 | 3 | 2 |
3 | 13 | 1626.52 | 32 | 12.76 | 2667 | 1089 | 2.97 / 309.03 | 2 | 3 |
4 | 13 | 943.04 | 32 | 13.35 | 1723 | 736 | 3.71 / 309.77 | 2 | 6 |
5 | 8 | 0.48 | 190 | 14.12 | 332 | 891 | 4.60 / 310.66 | 2 | 22 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 27 | 14.38 | 492 | 191 | 0.19 / 301.44 | 2 | 3 |
2 | 7 | 2007.12 | 47 | 11.54 | 3204 | 1738 | 1.93 / 303.18 | 2 | 2 |
3 | 13 | 1640.08 | 32 | 12.78 | 2687 | 1099 | 3.03 / 304.28 | 2 | 3 |
4 | 13 | 955.60 | 32 | 13.36 | 1736 | 742 | 3.77 / 305.02 | 2 | 7 |
5 | 13 | 19.32 | 32 | 14.32 | 357 | 164 | 3.93 / 305.18 | 2 | 8 |
6 | 8 | 0.00 | 190 | 14.05 | 329 | 878 | 4.81 / 306.06 | 2 | 20 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 28 | 14.39 | 485 | 195 | 0.20 / 296.75 | 2 | 3 |
2 | 3 | 949.80 | -1 | 14.39 | 485 | 0 | 0.00 / 296.75 | 2 | 3 |
3 | 7 | 2001.84 | 46 | 11.62 | 3199 | 1710 | 1.91 / 298.46 | 2 | 2 |
4 | 13 | 1802.08 | 32 | 12.64 | 2936 | 1188 | 3.09 / 299.65 | 2 | 3 |
5 | 13 | 898.16 | 32 | 13.40 | 1662 | 713 | 3.81 / 300.36 | 2 | 7 |
6 | 8 | 0.08 | 190 | 14.13 | 332 | 891 | 4.70 / 301.25 | 2 | 19 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 27 | 14.39 | 506 | 197 | 0.20 / 291.94 | 2 | 3 |
2 | 3 | 1048.52 | 1 | 13.68 | 1896 | 26 | 0.22 / 291.97 | 2 | 2 |
3 | 7 | 2003.20 | 46 | 11.75 | 3202 | 1731 | 1.95 / 293.70 | 2 | 2 |
4 | 13 | 1608.60 | 32 | 12.85 | 2632 | 1082 | 3.04 / 294.78 | 2 | 3 |
5 | 13 | 931.28 | 32 | 13.41 | 1685 | 723 | 3.76 / 295.50 | 2 | 6 |
6 | 13 | 35.00 | 32 | 14.32 | 384 | 176 | 3.93 / 295.68 | 2 | 9 |
7 | 8 | 0.12 | 190 | 14.10 | 326 | 873 | 4.81 / 296.55 | 2 | 23 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 27 | 14.40 | 494 | 192 | 0.19 / 287.34 | 2 | 3 |
2 | 7 | 2009.04 | 47 | 11.86 | 3210 | 1789 | 1.98 / 289.13 | 2 | 2 |
3 | 13 | 1617.12 | 32 | 12.85 | 2655 | 1092 | 3.07 / 290.22 | 2 | 3 |
4 | 13 | 745.00 | 32 | 13.59 | 1435 | 624 | 3.70 / 290.85 | 2 | 7 |
5 | 8 | 0.24 | 190 | 14.15 | 333 | 895 | 4.59 / 291.74 | 2 | 17 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 27 | 14.44 | 476 | 186 | 0.19 / 282.82 | 2 | 3 |
2 | 7 | 2005.08 | 46 | 11.96 | 3195 | 1758 | 1.94 / 284.58 | 2 | 2 |
3 | 13 | 1611.12 | 32 | 12.87 | 2643 | 1088 | 3.03 / 285.66 | 2 | 4 |
4 | 13 | 747.48 | 32 | 13.61 | 1424 | 620 | 3.65 / 286.28 | 2 | 6 |
5 | 8 | -0.12 | 190 | 14.17 | 322 | 867 | 4.52 / 287.15 | 2 | 16 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 28 | 14.43 | 482 | 195 | 0.19 / 278.14 | 2 | 3 |
2 | 3 | 965.64 | -1 | 14.43 | 482 | 0 | 0.00 / 278.14 | 2 | 3 |
3 | 7 | 2004.64 | 46 | 12.06 | 3215 | 1784 | 1.98 / 279.92 | 2 | 2 |
4 | 13 | 1606.32 | 32 | 12.92 | 2622 | 1084 | 3.06 / 281.00 | 2 | 4 |
5 | 13 | 722.92 | 32 | 13.64 | 1388 | 606 | 3.67 / 281.61 | 2 | 7 |
6 | 13 | 3.00 | 32 | 14.37 | 330 | 152 | 3.82 / 281.76 | 2 | 10 |
7 | 8 | 0.04 | 190 | 14.11 | 325 | 871 | 4.69 / 282.63 | 2 | 21 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 27 | 14.42 | 492 | 192 | 0.19 / 273.54 | 2 | 3 |
2 | 7 | 2003.20 | 47 | 12.14 | 3209 | 1831 | 2.02 / 275.37 | 2 | 2 |
3 | 13 | 1610.64 | 32 | 12.94 | 2627 | 1088 | 3.11 / 276.46 | 2 | 4 |
4 | 13 | 725.40 | 32 | 13.65 | 1395 | 609 | 3.72 / 277.07 | 2 | 7 |
5 | 8 | 0.44 | 190 | 14.18 | 324 | 873 | 4.59 / 277.94 | 2 | 16 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 29 | 14.42 | 488 | 204 | 0.20 / 268.91 | 2 | 3 |
2 | 3 | 948.68 | -1 | 14.42 | 488 | 0 | 0.00 / 268.91 | 2 | 3 |
3 | 7 | 2005.20 | 47 | 12.16 | 3211 | 1835 | 2.04 / 270.74 | 2 | 2 |
4 | 13 | 1604.36 | 32 | 12.94 | 2636 | 1092 | 3.13 / 271.83 | 2 | 4 |
5 | 13 | 730.24 | 32 | 13.64 | 1416 | 618 | 3.75 / 272.45 | 2 | 7 |
6 | 8 | 0.04 | 190 | 14.17 | 334 | 899 | 4.65 / 273.35 | 2 | 19 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 28 | 14.46 | 488 | 198 | 0.20 / 264.27 | 2 | 2 |
2 | 3 | 1028.96 | 1 | 13.67 | 1864 | 25 | 0.22 / 264.29 | 2 | 2 |
3 | 7 | 2003.96 | 47 | 12.20 | 3210 | 1841 | 2.06 / 266.13 | 2 | 2 |
4 | 13 | 1588.08 | 32 | 12.97 | 2604 | 1081 | 3.14 / 267.22 | 2 | 3 |
5 | 13 | 699.72 | 32 | 13.68 | 1356 | 594 | 3.74 / 267.81 | 2 | 6 |
6 | 8 | 0.24 | 190 | 14.19 | 331 | 892 | 4.63 / 268.70 | 2 | 19 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 29 | 14.46 | 486 | 204 | 0.20 / 259.52 | 2 | 2 |
2 | 3 | 960.72 | -1 | 14.46 | 486 | 0 | 0.00 / 259.52 | 2 | 2 |
3 | 3 | 1019.12 | 1 | 13.19 | 1856 | 24 | 0.23 / 259.54 | 2 | 2 |
4 | 7 | 2006.52 | 46 | 12.21 | 3214 | 1805 | 2.03 / 261.35 | 2 | 2 |
5 | 13 | 1588.36 | 32 | 12.97 | 2619 | 1087 | 3.12 / 262.44 | 2 | 4 |
6 | 13 | 704.32 | 32 | 13.68 | 1372 | 601 | 3.72 / 263.04 | 2 | 6 |
7 | 13 | 16.20 | 32 | 14.37 | 355 | 163 | 3.88 / 263.20 | 2 | 9 |
8 | 8 | 0.00 | 190 | 14.13 | 324 | 870 | 4.75 / 264.07 | 2 | 21 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 28 | 14.49 | 483 | 196 | 0.20 / 254.90 | 2 | 2 |
2 | 7 | 2005.88 | 46 | 12.23 | 3213 | 1808 | 2.00 / 256.71 | 2 | 2 |
3 | 13 | 1617.72 | 32 | 12.96 | 2660 | 1103 | 3.11 / 257.81 | 2 | 4 |
4 | 13 | 735.16 | 32 | 13.65 | 1421 | 621 | 3.73 / 258.43 | 2 | 7 |
5 | 8 | 0.32 | 190 | 14.19 | 328 | 884 | 4.61 / 259.32 | 2 | 20 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 28 | 14.47 | 491 | 199 | 0.20 / 250.34 | 2 | 2 |
2 | 7 | 2008.68 | 46 | 12.11 | 3220 | 1794 | 1.99 / 252.14 | 2 | 2 |
3 | 13 | 1598.96 | 32 | 12.94 | 2620 | 1085 | 3.08 / 253.22 | 2 | 4 |
4 | 13 | 727.00 | 32 | 13.65 | 1395 | 609 | 3.69 / 253.83 | 2 | 7 |
5 | 8 | 0.20 | 190 | 14.20 | 324 | 874 | 4.56 / 254.70 | 2 | 19 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 28 | 14.45 | 480 | 194 | 0.19 / 245.49 | 2 | 2 |
2 | 7 | 2001.52 | 46 | 12.11 | 3207 | 1786 | 1.98 / 247.28 | 2 | 2 |
3 | 13 | 1595.28 | 32 | 12.94 | 2613 | 1082 | 3.06 / 248.36 | 2 | 4 |
4 | 13 | 895.96 | 32 | 13.50 | 1646 | 711 | 3.77 / 249.07 | 2 | 7 |
5 | 13 | 36.12 | 32 | 14.35 | 385 | 177 | 3.95 / 249.25 | 2 | 9 |
6 | 8 | -0.04 | 190 | 14.15 | 332 | 893 | 4.84 / 250.14 | 2 | 20 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 28 | 14.48 | 475 | 193 | 0.19 / 240.92 | 2 | 2 |
2 | 7 | 2005.36 | 46 | 12.11 | 3208 | 1787 | 1.98 / 242.71 | 2 | 2 |
3 | 13 | 1600.12 | 32 | 12.93 | 2627 | 1087 | 3.07 / 243.80 | 2 | 4 |
4 | 13 | 722.16 | 32 | 13.66 | 1404 | 614 | 3.68 / 244.41 | 2 | 7 |
5 | 8 | 0.20 | 190 | 14.20 | 330 | 890 | 4.57 / 245.30 | 2 | 18 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 28 | 14.49 | 485 | 197 | 0.20 / 236.04 | 2 | 2 |
2 | 7 | 2010.52 | 46 | 12.12 | 3218 | 1794 | 1.99 / 237.84 | 2 | 2 |
3 | 13 | 1605.48 | 32 | 12.93 | 2648 | 1096 | 3.09 / 238.93 | 2 | 4 |
4 | 13 | 911.28 | 32 | 13.50 | 1676 | 724 | 3.81 / 239.66 | 2 | 7 |
5 | 13 | 27.88 | 32 | 14.36 | 382 | 176 | 3.99 / 239.83 | 2 | 9 |
6 | 8 | 0.20 | 190 | 14.15 | 334 | 898 | 4.88 / 240.73 | 2 | 20 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 28 | 14.50 | 475 | 193 | 0.19 / 231.43 | 2 | 2 |
2 | 7 | 2004.08 | 47 | 12.14 | 3204 | 1828 | 2.02 / 233.26 | 2 | 2 |
3 | 13 | 1598.56 | 32 | 12.94 | 2620 | 1085 | 3.11 / 234.35 | 2 | 4 |
4 | 13 | 712.28 | 32 | 13.67 | 1385 | 606 | 3.71 / 234.95 | 2 | 7 |
5 | 8 | 0.20 | 190 | 14.23 | 331 | 895 | 4.61 / 235.85 | 2 | 20 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 29 | 14.51 | 464 | 195 | 0.20 / 226.85 | 2 | 2 |
2 | 3 | 950.36 | -1 | 14.51 | 464 | 0 | 0.00 / 226.85 | 2 | 2 |
3 | 7 | 2008.20 | 46 | 12.15 | 3217 | 1798 | 1.99 / 228.65 | 2 | 2 |
4 | 13 | 1607.04 | 32 | 12.95 | 2637 | 1093 | 3.09 / 229.74 | 2 | 4 |
5 | 13 | 711.12 | 32 | 13.68 | 1385 | 606 | 3.69 / 230.35 | 2 | 7 |
6 | 8 | -0.04 | 190 | 14.22 | 331 | 894 | 4.59 / 231.24 | 2 | 20 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 28 | 14.53 | 484 | 197 | 0.20 / 222.28 | 2 | 2 |
2 | 3 | 1028.84 | 1 | 13.80 | 1861 | 26 | 0.22 / 222.30 | 2 | 2 |
3 | 7 | 2007.56 | 46 | 12.17 | 3221 | 1803 | 2.03 / 224.11 | 2 | 2 |
4 | 13 | 1609.60 | 32 | 12.97 | 2621 | 1088 | 3.11 / 225.19 | 2 | 4 |
5 | 13 | 702.40 | 32 | 13.71 | 1354 | 594 | 3.71 / 225.79 | 2 | 7 |
6 | 8 | -0.04 | 190 | 14.25 | 319 | 864 | 4.57 / 226.65 | 2 | 18 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 28 | 14.53 | 470 | 191 | 0.19 / 217.77 | 2 | 2 |
2 | 7 | 2007.16 | 46 | 12.21 | 3212 | 1804 | 2.00 / 219.57 | 2 | 2 |
3 | 13 | 1597.96 | 31 | 12.98 | 2618 | 1053 | 3.05 / 220.63 | 2 | 4 |
4 | 13 | 704.68 | 31 | 13.71 | 1367 | 581 | 3.63 / 221.21 | 2 | 7 |
5 | 8 | 0.32 | 190 | 14.27 | 322 | 873 | 4.50 / 222.08 | 2 | 18 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 27 | 14.53 | 481 | 189 | 0.19 / 213.09 | 2 | 2 |
2 | 3 | 1025.40 | 1 | 13.80 | 1866 | 26 | 0.21 / 213.12 | 2 | 2 |
3 | 7 | 2005.56 | 46 | 12.25 | 3217 | 1813 | 2.03 / 214.93 | 2 | 2 |
4 | 13 | 1608.00 | 28 | 13.02 | 2647 | 965 | 2.99 / 215.90 | 2 | 4 |
5 | 13 | 928.84 | 28 | 13.55 | 1698 | 644 | 3.64 / 216.54 | 2 | 7 |
6 | 13 | 47.80 | 28 | 14.40 | 398 | 160 | 3.80 / 216.70 | 2 | 8 |
7 | 8 | 0.12 | 190 | 14.20 | 325 | 877 | 4.67 / 217.58 | 2 | 24 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 28 | 14.52 | 477 | 194 | 0.19 / 208.50 | 2 | 2 |
2 | 3 | 969.12 | -1 | 14.52 | 477 | 0 | 0.00 / 208.50 | 2 | 2 |
3 | 3 | 1022.96 | 1 | 13.62 | 1851 | 25 | 0.22 / 208.53 | 2 | 2 |
4 | 7 | 2001.88 | 46 | 12.29 | 3206 | 1812 | 2.03 / 210.34 | 2 | 2 |
5 | 13 | 1597.52 | 28 | 13.04 | 2632 | 961 | 2.99 / 211.30 | 2 | 4 |
6 | 13 | 754.84 | 28 | 13.71 | 1448 | 556 | 3.55 / 211.86 | 2 | 7 |
7 | 13 | 51.96 | 28 | 14.40 | 411 | 166 | 3.71 / 212.02 | 2 | 9 |
8 | 8 | 0.08 | 190 | 14.22 | 326 | 881 | 4.59 / 212.90 | 2 | 19 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 28 | 14.54 | 470 | 191 | 0.19 / 203.86 | 2 | 2 |
2 | 7 | 2003.60 | 46 | 12.34 | 3206 | 1820 | 2.01 / 205.68 | 2 | 2 |
3 | 13 | 1582.20 | 28 | 13.08 | 2588 | 948 | 2.96 / 206.63 | 2 | 4 |
4 | 13 | 896.84 | 28 | 13.60 | 1649 | 628 | 3.59 / 207.26 | 2 | 7 |
5 | 13 | 32.64 | 28 | 14.42 | 384 | 155 | 3.74 / 207.41 | 2 | 9 |
6 | 8 | 0.12 | 190 | 14.21 | 332 | 896 | 4.64 / 208.31 | 2 | 23 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 28 | 14.55 | 490 | 200 | 0.20 / 199.34 | 2 | 3 |
2 | 7 | 2004.80 | 46 | 12.37 | 3221 | 1833 | 2.03 / 201.17 | 2 | 2 |
3 | 13 | 1596.72 | 28 | 13.09 | 2640 | 968 | 3.00 / 202.14 | 2 | 4 |
4 | 13 | 715.40 | 28 | 13.78 | 1382 | 533 | 3.53 / 202.67 | 2 | 7 |
5 | 13 | 8.92 | 28 | 14.47 | 337 | 137 | 3.67 / 202.81 | 2 | 9 |
6 | 8 | 0.16 | 190 | 14.24 | 319 | 863 | 4.53 / 203.67 | 2 | 19 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 28 | 14.57 | 480 | 196 | 0.20 / 194.63 | 2 | 3 |
2 | 7 | 2002.48 | 46 | 12.45 | 3210 | 1838 | 2.03 / 196.47 | 3 | 2 |
3 | 13 | 1586.04 | 28 | 13.12 | 2612 | 960 | 2.99 / 197.43 | 2 | 4 |
4 | 13 | 898.84 | 28 | 13.64 | 1649 | 630 | 3.62 / 198.06 | 2 | 7 |
5 | 13 | 66.60 | 28 | 14.41 | 433 | 175 | 3.80 / 198.23 | 2 | 9 |
6 | 8 | 0.04 | 190 | 14.23 | 335 | 906 | 4.70 / 199.14 | 2 | 23 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 28 | 14.55 | 490 | 200 | 0.20 / 190.21 | 2 | 3 |
2 | 7 | 2002.08 | 46 | 12.46 | 3216 | 1843 | 2.04 / 192.05 | 3 | 2 |
3 | 13 | 1586.60 | 28 | 13.15 | 2610 | 961 | 3.00 / 193.01 | 2 | 4 |
4 | 13 | 717.24 | 28 | 13.81 | 1384 | 535 | 3.54 / 193.55 | 2 | 7 |
5 | 8 | 0.20 | 190 | 14.30 | 327 | 888 | 4.43 / 194.43 | 2 | 18 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 27 | 14.58 | 502 | 198 | 0.20 / 185.70 | 2 | 3 |
2 | 7 | 2002.24 | 47 | 12.50 | 3217 | 1890 | 2.09 / 187.59 | 2 | 3 |
3 | 13 | 1603.44 | 28 | 13.14 | 2650 | 975 | 3.06 / 188.57 | 2 | 4 |
4 | 13 | 731.92 | 28 | 13.81 | 1408 | 544 | 3.61 / 189.11 | 2 | 7 |
5 | 8 | 0.04 | 190 | 14.31 | 329 | 895 | 4.50 / 190.01 | 2 | 18 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 27 | 14.59 | 484 | 191 | 0.19 / 180.93 | 2 | 3 |
2 | 7 | 2009.52 | 47 | 12.52 | 3224 | 1897 | 2.09 / 182.83 | 3 | 3 |
3 | 13 | 1588.64 | 28 | 13.18 | 2607 | 962 | 3.05 / 183.79 | 2 | 4 |
4 | 13 | 907.68 | 28 | 13.68 | 1666 | 638 | 3.69 / 184.43 | 2 | 7 |
5 | 13 | 35.04 | 28 | 14.47 | 394 | 160 | 3.85 / 184.59 | 2 | 9 |
6 | 8 | 0.08 | 190 | 14.25 | 338 | 915 | 4.76 / 185.51 | 2 | 22 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 29 | 14.58 | 481 | 203 | 0.20 / 176.50 | 2 | 3 |
2 | 3 | 929.40 | -1 | 14.58 | 481 | 0 | 0.00 / 176.50 | 2 | 3 |
3 | 7 | 2002.00 | 46 | 12.54 | 3213 | 1853 | 2.06 / 178.35 | 3 | 3 |
4 | 13 | 1569.36 | 28 | 13.19 | 2591 | 957 | 3.01 / 179.31 | 2 | 4 |
5 | 13 | 690.28 | 28 | 13.87 | 1349 | 524 | 3.54 / 179.83 | 2 | 8 |
6 | 8 | 0.24 | 190 | 14.33 | 335 | 912 | 4.45 / 180.74 | 2 | 21 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 27 | 14.61 | 492 | 194 | 0.19 / 171.91 | 2 | 3 |
2 | 3 | 1053.08 | 1 | 14.22 | 1902 | 27 | 0.22 / 171.93 | 2 | 3 |
3 | 7 | 2001.36 | 46 | 12.57 | 3218 | 1861 | 2.08 / 173.79 | 2 | 3 |
4 | 13 | 1580.64 | 28 | 13.21 | 2602 | 962 | 3.04 / 174.76 | 2 | 4 |
5 | 13 | 704.40 | 28 | 13.87 | 1363 | 529 | 3.57 / 175.29 | 2 | 8 |
6 | 13 | 5.56 | 28 | 14.54 | 330 | 134 | 3.71 / 175.42 | 2 | 10 |
7 | 8 | -0.08 | 190 | 14.30 | 321 | 872 | 4.58 / 176.29 | 2 | 22 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 27 | 14.60 | 490 | 193 | 0.19 / 167.68 | 2 | 3 |
2 | 7 | 1810.56 | 46 | 12.61 | 2947 | 1709 | 1.90 / 169.39 | 2 | 3 |
3 | 13 | 1426.32 | 28 | 13.28 | 2367 | 880 | 2.78 / 170.27 | 2 | 5 |
4 | 13 | 747.00 | 28 | 13.83 | 1423 | 551 | 3.33 / 170.82 | 2 | 8 |
5 | 8 | 0.04 | 190 | 14.34 | 328 | 894 | 4.23 / 171.71 | 2 | 18 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 27 | 14.62 | 477 | 188 | 0.19 / 163.72 | 2 | 3 |
2 | 7 | 1504.12 | 47 | 12.76 | 2510 | 1505 | 1.69 / 165.22 | 3 | 4 |
3 | 13 | 1341.80 | 28 | 13.31 | 2254 | 840 | 2.53 / 166.06 | 2 | 5 |
4 | 13 | 681.64 | 28 | 13.88 | 1328 | 516 | 3.05 / 166.58 | 2 | 8 |
5 | 8 | 0.32 | 190 | 14.31 | 333 | 905 | 3.96 / 167.49 | 2 | 20 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 26 | 14.60 | 483 | 183 | 0.18 / 160.01 | 2 | 3 |
2 | 7 | 1382.68 | 47 | 12.88 | 2343 | 1418 | 1.60 / 161.42 | 2 | 4 |
3 | 13 | 1204.36 | 28 | 13.42 | 2067 | 777 | 2.38 / 162.20 | 2 | 5 |
4 | 13 | 572.48 | 28 | 14.00 | 1175 | 461 | 2.84 / 162.66 | 2 | 7 |
5 | 8 | 0.04 | 190 | 14.34 | 319 | 869 | 3.71 / 163.53 | 2 | 16 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 27 | 14.61 | 482 | 190 | 0.19 / 156.22 | 2 | 4 |
2 | 3 | 965.44 | -1 | 14.61 | 482 | 0 | 0.00 / 156.22 | 2 | 4 |
3 | 7 | 1428.40 | 46 | 12.90 | 2399 | 1424 | 1.61 / 157.64 | 2 | 4 |
4 | 13 | 1258.16 | 28 | 13.41 | 2134 | 801 | 2.41 / 158.44 | 2 | 5 |
5 | 13 | 608.16 | 28 | 13.98 | 1223 | 479 | 2.89 / 158.92 | 2 | 8 |
6 | 8 | 0.12 | 190 | 14.34 | 330 | 899 | 3.79 / 159.82 | 2 | 20 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 28 | 14.63 | 491 | 201 | 0.20 / 152.09 | 2 | 3 |
2 | 3 | 973.16 | -1 | 14.63 | 491 | 0 | 0.00 / 152.09 | 2 | 3 |
3 | 3 | 1032.68 | 1 | 14.18 | 1881 | 27 | 0.23 / 152.12 | 2 | 2 |
4 | 7 | 1794.88 | 46 | 12.84 | 2920 | 1725 | 1.95 / 153.84 | 2 | 3 |
5 | 13 | 1387.60 | 28 | 13.41 | 2323 | 872 | 2.82 / 154.71 | 2 | 5 |
6 | 13 | 508.04 | 28 | 14.09 | 1088 | 429 | 3.25 / 155.14 | 2 | 8 |
7 | 8 | -0.12 | 190 | 14.34 | 325 | 885 | 4.14 / 156.03 | 2 | 18 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 27 | 14.65 | 497 | 197 | 0.20 / 147.30 | 2 | 3 |
2 | 7 | 1965.44 | 82 | 12.52 | 3162 | 3246 | 3.44 / 150.55 | 2 | 3 |
3 | 13 | 525.20 | 28 | 14.13 | 1117 | 442 | 3.88 / 150.99 | 2 | 8 |
4 | 8 | 0.28 | 190 | 14.40 | 330 | 903 | 4.79 / 151.89 | 2 | 18 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 27 | 14.65 | 501 | 198 | 0.20 / 142.43 | 2 | 3 |
2 | 3 | 1020.36 | 1 | 14.31 | 1862 | 27 | 0.22 / 142.46 | 2 | 2 |
3 | 7 | 1948.40 | 82 | 12.51 | 3120 | 3201 | 3.43 / 145.66 | 2 | 3 |
4 | 13 | 724.24 | 28 | 13.97 | 1404 | 549 | 3.97 / 146.21 | 2 | 8 |
5 | 8 | 0.12 | 190 | 14.39 | 328 | 897 | 4.87 / 147.10 | 2 | 18 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 26 | 14.68 | 488 | 186 | 0.19 / 138.30 | 2 | 3 |
2 | 7 | 1679.32 | 51 | 12.94 | 2748 | 1814 | 2.00 / 140.11 | 2 | 3 |
3 | 13 | 1291.24 | 28 | 13.51 | 2197 | 831 | 2.83 / 140.94 | 2 | 5 |
4 | 13 | 398.16 | 28 | 14.22 | 944 | 376 | 3.21 / 141.32 | 2 | 8 |
5 | 8 | -0.16 | 190 | 14.37 | 334 | 912 | 4.12 / 142.23 | 2 | 19 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 28 | 14.67 | 477 | 196 | 0.20 / 133.98 | 2 | 3 |
2 | 3 | 930.88 | -1 | 14.67 | 477 | 0 | 0.00 / 133.98 | 2 | 3 |
3 | 7 | 1843.32 | 50 | 12.92 | 2980 | 1925 | 2.12 / 135.91 | 3 | 3 |
4 | 13 | 1424.36 | 28 | 13.48 | 2360 | 891 | 3.01 / 136.80 | 2 | 5 |
5 | 13 | 529.16 | 28 | 14.14 | 1114 | 441 | 3.45 / 137.24 | 2 | 8 |
6 | 8 | 0.40 | 190 | 14.41 | 318 | 871 | 4.32 / 138.11 | 2 | 19 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 28 | 14.68 | 479 | 197 | 0.20 / 129.85 | 2 | 3 |
2 | 7 | 1823.24 | 50 | 12.99 | 2936 | 1907 | 2.10 / 131.75 | 3 | 3 |
3 | 13 | 1225.96 | 28 | 13.61 | 2097 | 799 | 2.90 / 132.55 | 2 | 6 |
4 | 13 | 364.84 | 28 | 14.29 | 876 | 351 | 3.25 / 132.90 | 2 | 8 |
5 | 8 | 0.08 | 190 | 14.41 | 324 | 887 | 4.14 / 133.79 | 2 | 18 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 28 | 14.68 | 488 | 201 | 0.20 / 125.42 | 2 | 3 |
2 | 7 | 1792.12 | 50 | 13.05 | 2891 | 1886 | 2.09 / 127.31 | 2 | 4 |
3 | 13 | 1384.44 | 28 | 13.54 | 2291 | 869 | 2.96 / 128.18 | 2 | 5 |
4 | 13 | 280.76 | 28 | 14.38 | 755 | 304 | 3.26 / 128.48 | 2 | 8 |
5 | 13 | 19.08 | 28 | 14.63 | 358 | 147 | 3.41 / 128.63 | 2 | 10 |
6 | 13 | 8.00 | 28 | 14.55 | 340 | 139 | 3.54 / 128.77 | 2 | 12 |
7 | 8 | -0.12 | 190 | 14.34 | 324 | 883 | 4.43 / 129.65 | 2 | 22 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 26 | 14.69 | 495 | 189 | 0.19 / 121.54 | 2 | 3 |
2 | 3 | 1035.16 | 1 | 14.53 | 1885 | 27 | 0.22 / 121.57 | 2 | 2 |
3 | 7 | 1539.76 | 51 | 13.21 | 2524 | 1700 | 1.92 / 123.27 | 2 | 4 |
4 | 13 | 1152.84 | 28 | 13.67 | 1979 | 757 | 2.67 / 124.03 | 2 | 6 |
5 | 13 | 300.00 | 28 | 14.36 | 778 | 313 | 2.99 / 124.34 | 2 | 8 |
6 | 8 | -0.08 | 190 | 14.42 | 321 | 879 | 3.87 / 125.22 | 2 | 22 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 26 | 14.70 | 482 | 184 | 0.18 / 117.36 | 2 | 3 |
2 | 7 | 1745.20 | 51 | 13.15 | 2833 | 1900 | 2.08 / 119.26 | 2 | 4 |
3 | 13 | 1158.48 | 28 | 13.69 | 1986 | 761 | 2.85 / 120.02 | 2 | 6 |
4 | 13 | 483.92 | 28 | 14.21 | 1055 | 420 | 3.27 / 120.44 | 2 | 9 |
5 | 8 | 0.24 | 190 | 14.41 | 334 | 914 | 4.18 / 121.35 | 2 | 21 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 26 | 14.72 | 471 | 180 | 0.18 / 113.22 | 2 | 3 |
2 | 7 | 1741.76 | 50 | 13.17 | 2813 | 1852 | 2.03 / 115.07 | 3 | 4 |
3 | 13 | 1322.56 | 28 | 13.61 | 2213 | 843 | 2.88 / 115.92 | 2 | 6 |
4 | 13 | 411.84 | 28 | 14.27 | 953 | 381 | 3.26 / 116.30 | 2 | 9 |
5 | 8 | -0.08 | 190 | 14.42 | 320 | 877 | 4.13 / 117.17 | 2 | 20 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 28 | 14.71 | 462 | 190 | 0.19 / 108.82 | 2 | 3 |
2 | 3 | 948.96 | -1 | 14.71 | 462 | 0 | 0.00 / 108.82 | 2 | 3 |
3 | 7 | 2002.52 | 50 | 13.06 | 3191 | 2084 | 2.27 / 110.90 | 2 | 3 |
4 | 13 | 1354.32 | 28 | 13.60 | 2262 | 861 | 3.14 / 111.76 | 2 | 5 |
5 | 13 | 456.88 | 28 | 14.24 | 1012 | 404 | 3.54 / 112.17 | 2 | 9 |
6 | 8 | 0.00 | 190 | 14.44 | 319 | 875 | 4.41 / 113.04 | 2 | 18 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 28 | 14.69 | 484 | 199 | 0.20 / 104.39 | 2 | 3 |
2 | 7 | 2001.88 | 50 | 13.05 | 3195 | 2085 | 2.28 / 106.48 | 3 | 3 |
3 | 13 | 1354.36 | 28 | 13.60 | 2273 | 866 | 3.15 / 107.34 | 2 | 6 |
4 | 13 | 470.96 | 28 | 14.24 | 1042 | 415 | 3.56 / 107.76 | 2 | 8 |
5 | 8 | 0.36 | 190 | 14.45 | 316 | 868 | 4.43 / 108.63 | 2 | 14 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 27 | 14.71 | 477 | 189 | 0.19 / 99.93 | 2 | 2 |
2 | 3 | 1037.68 | 1 | 14.58 | 1899 | 28 | 0.22 / 99.96 | 2 | 2 |
3 | 7 | 2001.64 | 50 | 13.06 | 3206 | 2094 | 2.31 / 102.05 | 2 | 3 |
4 | 13 | 1337.92 | 28 | 13.61 | 2220 | 846 | 3.16 / 102.90 | 2 | 5 |
5 | 13 | 437.72 | 28 | 14.27 | 987 | 394 | 3.55 / 103.29 | 2 | 9 |
6 | 8 | -0.04 | 190 | 14.44 | 328 | 900 | 4.45 / 104.19 | 2 | 19 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 27 | 14.71 | 469 | 186 | 0.19 / 95.33 | 2 | 3 |
2 | 3 | 965.04 | -1 | 14.71 | 469 | 0 | 0.00 / 95.33 | 2 | 3 |
3 | 3 | 1018.76 | 1 | 14.47 | 1871 | 27 | 0.21 / 95.35 | 2 | 2 |
4 | 7 | 2002.32 | 50 | 13.05 | 3212 | 2096 | 2.31 / 97.45 | 2 | 3 |
5 | 13 | 1355.52 | 28 | 13.59 | 2276 | 866 | 3.18 / 98.32 | 2 | 6 |
6 | 13 | 453.72 | 28 | 14.25 | 1014 | 405 | 3.58 / 98.72 | 2 | 9 |
7 | 13 | 15.16 | 28 | 14.68 | 348 | 143 | 3.72 / 98.86 | 2 | 11 |
8 | 8 | 0.00 | 190 | 14.38 | 322 | 880 | 4.60 / 99.74 | 2 | 18 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 27 | 14.71 | 491 | 195 | 0.20 / 90.89 | 2 | 3 |
2 | 7 | 2005.60 | 50 | 13.05 | 3186 | 2079 | 2.27 / 92.97 | 2 | 3 |
3 | 13 | 1369.72 | 28 | 13.59 | 2290 | 871 | 3.15 / 93.84 | 2 | 6 |
4 | 13 | 480.92 | 28 | 14.23 | 1051 | 419 | 3.56 / 94.26 | 2 | 9 |
5 | 8 | 0.16 | 190 | 14.43 | 323 | 886 | 4.45 / 95.14 | 2 | 18 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 27 | 14.72 | 485 | 193 | 0.19 / 86.38 | 2 | 3 |
2 | 7 | 2004.00 | 50 | 13.05 | 3213 | 2096 | 2.29 / 88.48 | 2 | 3 |
3 | 13 | 1371.28 | 28 | 13.61 | 2258 | 860 | 3.15 / 89.34 | 2 | 6 |
4 | 13 | 484.76 | 28 | 14.23 | 1059 | 422 | 3.57 / 89.76 | 2 | 9 |
5 | 8 | -0.08 | 190 | 14.42 | 340 | 932 | 4.50 / 90.69 | 2 | 17 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 27 | 14.73 | 461 | 183 | 0.18 / 81.95 | 2 | 2 |
2 | 7 | 2005.24 | 50 | 13.06 | 3193 | 2085 | 2.27 / 84.04 | 2 | 3 |
3 | 13 | 1354.20 | 28 | 13.61 | 2257 | 860 | 3.13 / 84.90 | 2 | 6 |
4 | 13 | 477.00 | 28 | 14.25 | 1036 | 413 | 3.54 / 85.31 | 2 | 9 |
5 | 8 | 0.20 | 190 | 14.44 | 319 | 875 | 4.42 / 86.19 | 2 | 15 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 27 | 14.74 | 456 | 181 | 0.18 / 77.64 | 2 | 2 |
2 | 7 | 2003.96 | 50 | 13.05 | 3192 | 2083 | 2.26 / 79.72 | 2 | 3 |
3 | 13 | 1371.60 | 28 | 13.60 | 2292 | 873 | 3.14 / 80.59 | 2 | 6 |
4 | 13 | 294.76 | 28 | 14.41 | 770 | 311 | 3.45 / 80.90 | 2 | 8 |
5 | 8 | 0.16 | 190 | 14.46 | 316 | 868 | 4.32 / 81.77 | 2 | 19 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 27 | 14.75 | 473 | 188 | 0.19 / 73.48 | 2 | 3 |
2 | 7 | 1748.24 | 50 | 13.18 | 2800 | 1845 | 2.03 / 75.32 | 2 | 4 |
3 | 13 | 1344.92 | 28 | 13.60 | 2257 | 859 | 2.89 / 76.18 | 2 | 6 |
4 | 13 | 444.80 | 28 | 14.28 | 995 | 398 | 3.29 / 76.58 | 2 | 9 |
5 | 8 | -0.08 | 190 | 14.45 | 319 | 876 | 4.17 / 77.46 | 2 | 20 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 27 | 14.80 | 460 | 184 | 0.18 / 69.43 | 2 | 2 |
2 | 7 | 1699.36 | 50 | 13.22 | 2736 | 1808 | 1.99 / 71.24 | 2 | 4 |
3 | 13 | 1268.20 | 28 | 13.66 | 2142 | 819 | 2.81 / 72.06 | 2 | 6 |
4 | 13 | 363.68 | 28 | 14.35 | 875 | 352 | 3.16 / 72.41 | 2 | 9 |
5 | 8 | 0.12 | 190 | 14.47 | 318 | 874 | 4.04 / 73.29 | 2 | 17 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 27 | 14.81 | 454 | 182 | 0.18 / 64.97 | 2 | 2 |
2 | 7 | 2003.80 | 51 | 13.09 | 3194 | 2132 | 2.31 / 67.10 | 2 | 3 |
3 | 13 | 1352.12 | 28 | 13.64 | 2251 | 860 | 3.17 / 67.96 | 2 | 6 |
4 | 13 | 467.44 | 28 | 14.27 | 1027 | 410 | 3.58 / 68.37 | 2 | 9 |
5 | 8 | 0.08 | 190 | 14.47 | 319 | 877 | 4.46 / 69.25 | 2 | 19 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 27 | 14.82 | 460 | 184 | 0.18 / 60.54 | 2 | 2 |
2 | 7 | 2004.72 | 50 | 13.09 | 3216 | 2105 | 2.29 / 62.65 | 2 | 3 |
3 | 13 | 1353.56 | 28 | 13.64 | 2255 | 861 | 3.15 / 63.51 | 2 | 6 |
4 | 13 | 454.52 | 28 | 14.28 | 1014 | 405 | 3.56 / 63.91 | 2 | 9 |
5 | 8 | 0.00 | 190 | 14.48 | 319 | 878 | 4.43 / 64.79 | 2 | 16 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 27 | 14.83 | 454 | 182 | 0.18 / 56.14 | 2 | 2 |
2 | 7 | 2004.44 | 50 | 13.12 | 3189 | 2092 | 2.27 / 58.23 | 2 | 3 |
3 | 13 | 1333.48 | 28 | 13.66 | 2214 | 847 | 3.12 / 59.08 | 2 | 6 |
4 | 13 | 446.28 | 28 | 14.30 | 1004 | 402 | 3.52 / 59.48 | 2 | 9 |
5 | 8 | 0.24 | 190 | 14.50 | 318 | 876 | 4.40 / 60.36 | 2 | 17 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 27 | 14.84 | 461 | 185 | 0.18 / 51.63 | 2 | 2 |
2 | 7 | 2003.84 | 50 | 13.11 | 3211 | 2105 | 2.29 / 53.74 | 2 | 3 |
3 | 13 | 1353.76 | 27 | 13.67 | 2268 | 837 | 3.13 / 54.57 | 2 | 6 |
4 | 13 | 470.32 | 27 | 14.30 | 1032 | 398 | 3.53 / 54.97 | 2 | 8 |
5 | 13 | 2.56 | 27 | 14.82 | 323 | 129 | 3.65 / 55.10 | 2 | 12 |
6 | 8 | -0.08 | 190 | 14.47 | 312 | 858 | 4.51 / 55.96 | 2 | 18 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 26 | 14.82 | 465 | 179 | 0.18 / 47.12 | 2 | 2 |
2 | 3 | 1039.12 | 1 | 14.63 | 1887 | 28 | 0.21 / 47.14 | 2 | 2 |
3 | 7 | 2005.48 | 51 | 13.13 | 3205 | 2146 | 2.35 / 49.29 | 2 | 3 |
4 | 13 | 1168.24 | 27 | 13.77 | 2012 | 748 | 3.10 / 50.04 | 2 | 7 |
5 | 13 | 512.92 | 27 | 14.27 | 1098 | 423 | 3.52 / 50.46 | 2 | 9 |
6 | 13 | 1.96 | 27 | 14.83 | 319 | 128 | 3.65 / 50.59 | 2 | 11 |
7 | 8 | 0.08 | 190 | 14.47 | 312 | 858 | 4.51 / 51.45 | 2 | 19 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 27 | 14.78 | 469 | 187 | 0.19 / 42.73 | 2 | 2 |
2 | 3 | 955.64 | -1 | 14.78 | 469 | 0 | 0.00 / 42.73 | 2 | 2 |
3 | 7 | 2004.24 | 50 | 13.13 | 3179 | 2087 | 2.27 / 44.81 | 2 | 3 |
4 | 13 | 1342.72 | 27 | 13.67 | 2246 | 829 | 3.10 / 45.64 | 2 | 6 |
5 | 13 | 437.96 | 27 | 14.33 | 986 | 381 | 3.48 / 46.03 | 2 | 9 |
6 | 8 | -0.04 | 190 | 14.49 | 331 | 911 | 4.40 / 46.94 | 2 | 19 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 26 | 14.82 | 482 | 186 | 0.19 / 38.20 | 2 | 2 |
2 | 7 | 2001.40 | 51 | 13.12 | 3189 | 2134 | 2.32 / 40.33 | 2 | 3 |
3 | 13 | 1339.12 | 27 | 13.66 | 2250 | 830 | 3.15 / 41.16 | 2 | 6 |
4 | 13 | 647.44 | 27 | 14.14 | 1287 | 491 | 3.64 / 41.65 | 2 | 9 |
5 | 8 | 0.08 | 190 | 14.50 | 322 | 887 | 4.53 / 42.54 | 2 | 20 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 26 | 14.81 | 491 | 189 | 0.19 / 33.86 | 2 | 3 |
2 | 7 | 2006.24 | 50 | 13.12 | 3182 | 2087 | 2.28 / 35.94 | 2 | 3 |
3 | 13 | 1179.16 | 27 | 13.75 | 2028 | 753 | 3.03 / 36.70 | 2 | 6 |
4 | 13 | 513.76 | 27 | 14.26 | 1112 | 428 | 3.46 / 37.12 | 2 | 9 |
5 | 8 | 0.32 | 190 | 14.53 | 322 | 889 | 4.35 / 38.01 | 2 | 18 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 26 | 14.87 | 438 | 169 | 0.17 / 29.66 | 2 | 2 |
2 | 3 | 1018.92 | 1 | 14.61 | 1834 | 27 | 0.20 / 29.69 | 2 | 2 |
3 | 7 | 2003.24 | 50 | 13.13 | 3165 | 2078 | 2.27 / 31.77 | 2 | 3 |
4 | 13 | 1330.20 | 25 | 13.69 | 2188 | 749 | 3.02 / 32.52 | 2 | 6 |
5 | 13 | 441.52 | 25 | 14.37 | 960 | 345 | 3.37 / 32.86 | 2 | 9 |
6 | 8 | 0.08 | 190 | 14.55 | 291 | 804 | 4.17 / 33.67 | 2 | 19 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 26 | 14.84 | 429 | 166 | 0.17 / 25.35 | 2 | 2 |
2 | 3 | 968.32 | -1 | 14.84 | 429 | 0 | 0.00 / 25.35 | 2 | 2 |
3 | 3 | 1020.28 | 1 | 14.59 | 1845 | 27 | 0.19 / 25.38 | 2 | 2 |
4 | 7 | 2003.68 | 50 | 13.11 | 3168 | 2077 | 2.27 / 27.46 | 2 | 3 |
5 | 13 | 1349.12 | 25 | 13.65 | 2254 | 769 | 3.04 / 28.23 | 2 | 6 |
6 | 13 | 463.16 | 25 | 14.34 | 996 | 357 | 3.40 / 28.58 | 2 | 9 |
7 | 13 | 4.08 | 25 | 14.85 | 302 | 112 | 3.51 / 28.70 | 2 | 9 |
8 | 8 | 0.04 | 190 | 14.49 | 290 | 798 | 4.31 / 29.49 | 2 | 25 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 21 | 14.85 | 435 | 136 | 0.14 / 20.97 | 2 | 2 |
2 | 10 | 1053.52 | 4 | 14.60 | 1862 | 109 | 0.24 / 21.08 | 2 | 3 |
3 | 3 | 1047.20 | 1 | 14.65 | 1855 | 27 | 0.27 / 21.11 | 2 | 3 |
4 | 7 | 2002.88 | 51 | 13.11 | 3158 | 2111 | 2.38 / 23.22 | 2 | 3 |
5 | 13 | 1166.28 | 25 | 13.75 | 1972 | 678 | 3.06 / 23.90 | 2 | 6 |
6 | 13 | 528.20 | 25 | 14.27 | 1080 | 385 | 3.45 / 24.29 | 2 | 9 |
7 | 13 | 4.52 | 25 | 14.85 | 299 | 111 | 3.56 / 24.40 | 2 | 9 |
8 | 8 | 0.16 | 190 | 14.48 | 288 | 792 | 4.35 / 25.19 | 2 | 20 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 25 | 14.81 | 441 | 163 | 0.16 / 16.27 | 2 | 3 |
2 | 3 | 908.20 | -2 | 14.81 | 441 | 0 | 0.00 / 16.27 | 2 | 3 |
3 | 3 | 951.32 | -1 | 14.81 | 441 | 0 | 0.00 / 16.27 | 2 | 3 |
4 | 7 | 2000.92 | 75 | 12.95 | 3152 | 3061 | 3.22 / 19.33 | 3 | 4 |
5 | 13 | 757.00 | 20 | 14.12 | 1423 | 402 | 3.63 / 19.73 | 2 | 9 |
6 | 13 | 70.32 | 20 | 14.79 | 403 | 119 | 3.75 / 19.85 | 2 | 8 |
7 | 8 | -0.08 | 240 | 14.48 | 285 | 990 | 4.74 / 20.84 | 2 | 25 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 25 | 14.76 | 437 | 161 | 0.16 / 12.38 | 2 | 3 |
2 | 7 | 1506.12 | 74 | 13.26 | 2474 | 2428 | 2.59 / 14.80 | 3 | 4 |
3 | 13 | 508.96 | 20 | 14.33 | 1063 | 305 | 2.89 / 15.11 | 2 | 9 |
4 | 8 | 0.08 | 240 | 14.48 | 286 | 994 | 3.89 / 16.10 | 2 | 23 |
Average= | 3.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 25 | 14.74 | 448 | 165 | 0.17 / 8.46 | 2 | 3 |
2 | 7 | 1517.28 | 75 | 13.20 | 2481 | 2456 | 2.62 / 10.91 | 3 | 4 |
3 | 13 | 545.56 | 20 | 14.24 | 1112 | 317 | 2.94 / 11.23 | 2 | 8 |
4 | 8 | 0.08 | 240 | 14.47 | 284 | 986 | 3.92 / 12.22 | 2 | 24 |
Average= | 3.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 25 | 14.71 | 429 | 158 | 0.16 / 4.53 | 2 | 2 |
2 | 7 | 1513.84 | 75 | 13.14 | 2403 | 2368 | 2.53 / 6.90 | 2 | 3 |
3 | 13 | 560.32 | 20 | 14.18 | 1124 | 319 | 2.84 / 7.21 | 2 | 8 |
4 | 13 | 38.64 | 20 | 14.74 | 346 | 102 | 2.95 / 7.32 | 2 | 9 |
5 | 8 | 0.20 | 240 | 14.40 | 282 | 975 | 3.92 / 8.29 | 2 | 33 |
Average= | 2.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 25 | 14.60 | 418 | 153 | 0.15 / 1.68 | 2 | 2 |
2 | 7 | 1005.72 | 74 | 13.33 | 1750 | 1726 | 1.88 / 3.40 | 2 | 5 |
3 | 8 | 0.12 | 240 | 14.38 | 280 | 966 | 2.85 / 4.37 | 2 | 25 |
Average= | 2.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 128.36 | 24 | 14.20 | 460 | 157 | 0.16 / 0.16 | 2 | 2 |
2 | 7 | 137.04 | 74 | 14.07 | 462 | 481 | 0.64 / 0.64 | 2 | 3 |
3 | 8 | 0.24 | 240 | 14.38 | 257 | 887 | 1.52 / 1.52 | 2 | 22 |
Average= | 1.52 (KJ/cycle) |