SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 41 | 10.72 | 439 | 193 | 0.19 / 1511.56 | 3 | 3 |
2 | 12 | 1085.56 | 5 | 8.13 | 1883 | 77 | 0.27 / 1511.63 | 2 | 3 |
3 | 12 | 1153.08 | 68 | 7.99 | 1980 | 1076 | 1.35 / 1512.71 | 2 | 3 |
4 | 12 | 1158.44 | 150 | 7.98 | 1971 | 2359 | 3.70 / 1515.07 | 3 | 3 |
5 | 7 | 1132.80 | 25 | 8.07 | 1935 | 390 | 4.09 / 1515.46 | 3 | 3 |
6 | 8 | -0.32 | 180 | 10.93 | 272 | 535 | 4.63 / 1515.99 | 3 | 3 |
Average= | 126.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 40 | 10.71 | 430 | 184 | 0.18 / 1506.90 | 3 | 3 |
2 | 12 | 1085.60 | 5 | 8.08 | 1904 | 77 | 0.26 / 1506.98 | 2 | 3 |
3 | 12 | 1150.36 | 68 | 8.05 | 1978 | 1083 | 1.34 / 1508.06 | 2 | 3 |
4 | 12 | 1154.88 | 150 | 8.05 | 1961 | 2368 | 3.71 / 1510.43 | 3 | 3 |
5 | 7 | 1126.32 | 25 | 8.12 | 1932 | 392 | 4.10 / 1510.82 | 3 | 3 |
6 | 8 | 0.04 | 180 | 10.94 | 276 | 543 | 4.65 / 1511.36 | 3 | 3 |
Average= | 137.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 67 | 10.70 | 432 | 310 | 0.31 / 1504.21 | 3 | 3 |
2 | 3 | 229.52 | -15 | 10.70 | 432 | 0 | 0.00 / 1504.21 | 3 | 3 |
3 | 3 | 717.92 | -5 | 10.70 | 432 | 0 | 0.00 / 1504.21 | 3 | 3 |
4 | 7 | 1156.60 | 25 | 8.17 | 1986 | 406 | 0.72 / 1504.62 | 3 | 3 |
5 | 13 | 1089.96 | 43 | 8.22 | 1883 | 666 | 1.38 / 1505.28 | 2 | 3 |
6 | 13 | 968.64 | 43 | 8.47 | 1702 | 620 | 2.00 / 1505.90 | 2 | 3 |
7 | 13 | 241.88 | 43 | 10.27 | 639 | 282 | 2.28 / 1506.19 | 2 | 3 |
8 | 8 | 0.20 | 180 | 10.95 | 269 | 530 | 2.81 / 1506.72 | 3 | 4 |
Average= | 150.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 43 | 10.75 | 429 | 198 | 0.20 / 1494.99 | 3 | 3 |
2 | 3 | 908.80 | -2 | 10.75 | 429 | 0 | 0.00 / 1494.99 | 3 | 3 |
3 | 3 | 1058.68 | 2 | 8.58 | 1839 | 32 | 0.23 / 1495.02 | 2 | 3 |
4 | 12 | 1128.60 | 5 | 8.30 | 1930 | 80 | 0.31 / 1495.10 | 2 | 3 |
5 | 12 | 2000.68 | 68 | 5.91 | 3329 | 1338 | 1.65 / 1496.44 | 2 | 3 |
6 | 12 | 1999.80 | 150 | 5.39 | 3535 | 2858 | 4.51 / 1499.30 | 2 | 3 |
7 | 7 | 1981.96 | 25 | 5.25 | 3534 | 464 | 4.97 / 1499.76 | 3 | 3 |
8 | 13 | 1881.28 | 43 | 6.12 | 3091 | 813 | 5.78 / 1500.57 | 2 | 3 |
9 | 13 | 1777.28 | 43 | 6.35 | 2925 | 799 | 6.58 / 1501.37 | 2 | 3 |
10 | 13 | 1656.16 | 43 | 6.68 | 2721 | 782 | 7.36 / 1502.15 | 2 | 3 |
11 | 13 | 1264.00 | 43 | 7.59 | 2140 | 698 | 8.06 / 1502.85 | 2 | 3 |
12 | 13 | 707.08 | 43 | 9.01 | 1334 | 517 | 8.58 / 1503.37 | 2 | 3 |
13 | 8 | 0.12 | 180 | 10.94 | 271 | 534 | 9.11 / 1503.90 | 3 | 3 |
Average= | 167.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 43 | 10.69 | 426 | 196 | 0.20 / 1490.24 | 3 | 3 |
2 | 3 | 911.04 | -2 | 10.69 | 426 | 0 | 0.00 / 1490.24 | 3 | 3 |
3 | 3 | 1060.04 | 2 | 8.33 | 1848 | 31 | 0.23 / 1490.27 | 2 | 3 |
4 | 12 | 1138.16 | 5 | 8.05 | 1971 | 79 | 0.31 / 1490.35 | 2 | 3 |
5 | 12 | 1159.48 | 68 | 8.08 | 1992 | 1094 | 1.40 / 1491.44 | 2 | 3 |
6 | 12 | 1164.76 | 150 | 8.10 | 1980 | 2406 | 3.81 / 1493.85 | 3 | 3 |
7 | 7 | 1138.92 | 25 | 8.16 | 1949 | 398 | 4.20 / 1494.25 | 3 | 3 |
8 | 8 | -0.08 | 180 | 10.96 | 275 | 543 | 4.75 / 1494.79 | 3 | 4 |
Average= | 186.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 10 | 1970.28 | 17 | 5.14 | 3523 | 308 | 0.31 / 1480.42 | 2 | 3 |
2 | 3 | 1970.88 | 25 | 5.16 | 3460 | 446 | 0.75 / 1480.87 | 2 | 3 |
3 | 3 | 1984.80 | 25 | 5.16 | 3488 | 450 | 1.20 / 1481.32 | 2 | 3 |
4 | 7 | 1977.96 | 25 | 5.24 | 3473 | 455 | 1.66 / 1481.77 | 3 | 3 |
5 | 13 | 1962.68 | 43 | 5.20 | 3456 | 773 | 2.43 / 1482.54 | 2 | 3 |
6 | 13 | 1948.72 | 43 | 5.24 | 3435 | 774 | 3.21 / 1483.32 | 2 | 3 |
7 | 13 | 1924.52 | 43 | 5.26 | 3404 | 770 | 3.98 / 1484.09 | 2 | 3 |
8 | 13 | 1895.44 | 43 | 5.40 | 3294 | 765 | 4.74 / 1484.85 | 2 | 3 |
9 | 13 | 1859.60 | 43 | 5.74 | 3086 | 762 | 5.50 / 1485.62 | 2 | 3 |
10 | 13 | 1801.00 | 43 | 5.80 | 2986 | 745 | 6.25 / 1486.36 | 2 | 3 |
11 | 13 | 1710.92 | 43 | 6.20 | 2814 | 750 | 7.00 / 1487.11 | 2 | 3 |
12 | 13 | 1597.36 | 43 | 6.36 | 2649 | 724 | 7.72 / 1487.83 | 2 | 3 |
13 | 13 | 1467.36 | 43 | 6.72 | 2448 | 707 | 8.43 / 1488.54 | 2 | 3 |
14 | 13 | 1055.88 | 43 | 7.87 | 1841 | 623 | 9.05 / 1489.17 | 2 | 3 |
15 | 13 | 334.40 | 43 | 9.89 | 784 | 333 | 9.39 / 1489.50 | 2 | 3 |
16 | 8 | 0.00 | 180 | 10.91 | 278 | 546 | 9.93 / 1490.04 | 3 | 4 |
Average= | 212.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 10 | 2057.20 | 17 | 5.18 | 3619 | 319 | 0.32 / 1444.47 | 2 | 3 |
2 | 3 | 2057.68 | 27 | 5.19 | 3568 | 500 | 0.82 / 1444.97 | 2 | 3 |
3 | 3 | 2103.56 | 28 | 5.20 | 3610 | 526 | 1.34 / 1445.49 | 2 | 3 |
4 | 7 | 2106.32 | 25 | 5.20 | 3640 | 473 | 1.82 / 1445.97 | 3 | 3 |
5 | 13 | 2102.00 | 43 | 5.21 | 3627 | 813 | 2.63 / 1446.78 | 2 | 3 |
6 | 13 | 2099.20 | 43 | 5.19 | 3640 | 812 | 3.44 / 1447.59 | 2 | 3 |
7 | 13 | 2098.84 | 43 | 5.22 | 3626 | 814 | 4.26 / 1448.40 | 2 | 3 |
8 | 13 | 2092.68 | 43 | 5.19 | 3634 | 811 | 5.07 / 1449.22 | 2 | 3 |
9 | 13 | 2083.28 | 43 | 5.20 | 3617 | 809 | 5.88 / 1450.02 | 2 | 3 |
10 | 13 | 2083.84 | 43 | 5.20 | 3610 | 807 | 6.68 / 1450.83 | 2 | 3 |
11 | 13 | 2086.44 | 43 | 5.19 | 3606 | 805 | 7.49 / 1451.64 | 2 | 3 |
12 | 13 | 2083.88 | 43 | 5.20 | 3594 | 804 | 8.29 / 1452.44 | 2 | 3 |
13 | 13 | 2075.08 | 43 | 5.19 | 3592 | 802 | 9.09 / 1453.24 | 2 | 3 |
14 | 13 | 2067.48 | 43 | 5.19 | 3587 | 801 | 9.89 / 1454.04 | 2 | 3 |
15 | 13 | 2065.16 | 43 | 5.20 | 3577 | 800 | 10.69 / 1454.84 | 2 | 3 |
16 | 13 | 2069.60 | 43 | 5.19 | 3578 | 799 | 11.49 / 1455.64 | 2 | 3 |
17 | 13 | 2074.16 | 43 | 5.18 | 3575 | 796 | 12.29 / 1456.44 | 2 | 3 |
18 | 13 | 2063.56 | 43 | 5.17 | 3578 | 795 | 13.08 / 1457.23 | 2 | 3 |
19 | 13 | 2049.64 | 43 | 5.19 | 3553 | 793 | 13.88 / 1458.03 | 2 | 3 |
20 | 13 | 2049.92 | 43 | 5.20 | 3557 | 795 | 14.67 / 1458.82 | 2 | 3 |
21 | 13 | 2056.24 | 43 | 5.17 | 3553 | 790 | 15.46 / 1459.61 | 2 | 3 |
22 | 13 | 2053.92 | 43 | 5.18 | 3548 | 790 | 16.25 / 1460.40 | 2 | 3 |
23 | 13 | 2046.48 | 43 | 5.16 | 3547 | 787 | 17.04 / 1461.19 | 2 | 3 |
24 | 13 | 2038.24 | 43 | 5.19 | 3535 | 789 | 17.83 / 1461.98 | 2 | 3 |
25 | 13 | 2033.04 | 43 | 5.17 | 3532 | 785 | 18.61 / 1462.76 | 2 | 3 |
26 | 13 | 2033.28 | 43 | 5.16 | 3534 | 784 | 19.40 / 1463.55 | 2 | 3 |
27 | 13 | 2031.28 | 43 | 5.16 | 3525 | 782 | 20.18 / 1464.33 | 2 | 3 |
28 | 13 | 2027.56 | 43 | 5.15 | 3524 | 780 | 20.96 / 1465.11 | 2 | 3 |
29 | 13 | 2026.56 | 43 | 5.17 | 3540 | 787 | 21.75 / 1465.90 | 2 | 3 |
30 | 13 | 2021.00 | 43 | 5.18 | 3549 | 791 | 22.54 / 1466.69 | 2 | 3 |
31 | 13 | 2012.64 | 43 | 5.18 | 3539 | 788 | 23.33 / 1467.47 | 2 | 3 |
32 | 13 | 2012.40 | 43 | 5.19 | 3513 | 784 | 24.11 / 1468.26 | 2 | 3 |
33 | 13 | 2008.48 | 43 | 5.22 | 3501 | 786 | 24.90 / 1469.04 | 2 | 3 |
34 | 13 | 1994.68 | 43 | 5.21 | 3502 | 785 | 25.68 / 1469.83 | 2 | 3 |
35 | 13 | 1993.80 | 498 | 5.03 | 3118 | 7810 | 33.49 / 1477.64 | 2 | 3 |
36 | 14 | 1980.72 | 140 | 5.14 | 3438 | 2474 | 35.96 / 1480.11 | 2 | 3 |
Average= | 246.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 36 | 10.46 | 424 | 160 | 0.16 / 1411.51 | 3 | 3 |
2 | 10 | 1008.88 | 4 | 7.67 | 1752 | 54 | 0.21 / 1411.57 | 2 | 3 |
3 | 3 | 1068.16 | 2 | 7.20 | 1863 | 27 | 0.24 / 1411.59 | 2 | 3 |
4 | 3 | 1043.32 | 1 | 7.31 | 1837 | 13 | 0.25 / 1411.61 | 2 | 3 |
5 | 12 | 1131.12 | 5 | 7.17 | 1927 | 69 | 0.32 / 1411.68 | 2 | 3 |
6 | 12 | 2005.96 | 68 | 4.97 | 2776 | 938 | 1.26 / 1412.61 | 2 | 3 |
7 | 12 | 2008.24 | 150 | 4.87 | 2560 | 1870 | 3.13 / 1414.48 | 2 | 3 |
8 | 7 | 2014.40 | 25 | 4.89 | 2411 | 295 | 3.43 / 1414.78 | 3 | 3 |
9 | 13 | 2037.84 | 43 | 4.97 | 2718 | 581 | 4.01 / 1415.36 | 2 | 3 |
10 | 13 | 2056.68 | 43 | 4.98 | 2782 | 596 | 4.60 / 1415.96 | 2 | 3 |
11 | 13 | 2070.00 | 43 | 4.99 | 2822 | 606 | 5.21 / 1416.56 | 2 | 3 |
12 | 13 | 2071.32 | 43 | 5.00 | 2852 | 613 | 5.82 / 1417.17 | 2 | 3 |
13 | 13 | 2076.32 | 43 | 5.00 | 2880 | 619 | 6.44 / 1417.79 | 2 | 3 |
14 | 13 | 2067.44 | 43 | 5.01 | 2904 | 626 | 7.07 / 1418.42 | 2 | 3 |
15 | 13 | 2061.96 | 43 | 5.01 | 2926 | 630 | 7.70 / 1419.05 | 2 | 3 |
16 | 13 | 2066.00 | 43 | 5.02 | 2945 | 636 | 8.33 / 1419.69 | 2 | 3 |
17 | 13 | 2068.64 | 43 | 5.02 | 2965 | 640 | 8.97 / 1420.33 | 2 | 3 |
18 | 13 | 2068.00 | 43 | 5.03 | 2983 | 645 | 9.62 / 1420.97 | 2 | 3 |
19 | 13 | 2067.88 | 43 | 5.03 | 3000 | 649 | 10.27 / 1421.62 | 2 | 3 |
20 | 13 | 2067.60 | 43 | 5.04 | 3018 | 654 | 10.92 / 1422.27 | 2 | 3 |
21 | 13 | 2065.40 | 43 | 5.04 | 3034 | 658 | 11.58 / 1422.93 | 2 | 3 |
22 | 13 | 2067.48 | 43 | 5.04 | 3050 | 661 | 12.24 / 1423.59 | 2 | 3 |
23 | 13 | 2069.68 | 43 | 5.05 | 3065 | 666 | 12.90 / 1424.26 | 2 | 3 |
24 | 13 | 2068.28 | 43 | 5.05 | 3079 | 669 | 13.57 / 1424.93 | 2 | 3 |
25 | 13 | 2062.60 | 43 | 5.05 | 3093 | 672 | 14.24 / 1425.60 | 2 | 3 |
26 | 13 | 2061.16 | 43 | 5.06 | 3104 | 675 | 14.92 / 1426.27 | 2 | 3 |
27 | 13 | 2066.88 | 43 | 5.06 | 3116 | 678 | 15.60 / 1426.95 | 2 | 3 |
28 | 13 | 2067.84 | 43 | 5.06 | 3130 | 681 | 16.28 / 1427.63 | 2 | 3 |
29 | 13 | 2064.16 | 43 | 5.06 | 3142 | 684 | 16.96 / 1428.32 | 2 | 3 |
30 | 13 | 2063.48 | 43 | 5.07 | 3153 | 687 | 17.65 / 1429.00 | 2 | 3 |
31 | 13 | 2068.60 | 43 | 5.09 | 3162 | 692 | 18.34 / 1429.70 | 2 | 3 |
32 | 13 | 2066.04 | 43 | 5.07 | 3173 | 692 | 19.03 / 1430.39 | 2 | 3 |
33 | 13 | 2061.92 | 43 | 5.08 | 3219 | 703 | 19.74 / 1431.09 | 2 | 3 |
34 | 13 | 2064.96 | 43 | 5.09 | 3245 | 710 | 20.45 / 1431.80 | 2 | 3 |
35 | 13 | 2067.88 | 43 | 5.09 | 3270 | 716 | 21.16 / 1432.52 | 2 | 3 |
36 | 13 | 2066.00 | 43 | 5.09 | 3283 | 719 | 21.88 / 1433.23 | 2 | 3 |
37 | 13 | 2065.52 | 43 | 5.11 | 3291 | 723 | 22.60 / 1433.96 | 2 | 3 |
38 | 13 | 2065.92 | 43 | 5.10 | 3303 | 724 | 23.33 / 1434.68 | 2 | 3 |
39 | 13 | 2065.76 | 516 | 4.91 | 2720 | 6891 | 30.22 / 1441.57 | 2 | 3 |
40 | 14 | 2064.80 | 140 | 5.18 | 3551 | 2575 | 32.80 / 1444.15 | 2 | 3 |
Average= | 288.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 35 | 10.56 | 412 | 152 | 0.15 / 1407.29 | 3 | 3 |
2 | 10 | 1031.04 | 3 | 7.77 | 1787 | 42 | 0.19 / 1407.33 | 3 | 3 |
3 | 3 | 1101.40 | 3 | 7.63 | 1891 | 43 | 0.24 / 1407.37 | 2 | 3 |
4 | 3 | 1067.52 | 2 | 7.53 | 1844 | 28 | 0.26 / 1407.40 | 2 | 3 |
5 | 12 | 1126.32 | 5 | 6.87 | 1937 | 67 | 0.33 / 1407.46 | 2 | 3 |
6 | 12 | 1155.72 | 68 | 6.74 | 1968 | 902 | 1.23 / 1408.37 | 2 | 3 |
7 | 12 | 1161.60 | 150 | 6.45 | 1964 | 1900 | 3.13 / 1410.27 | 3 | 3 |
8 | 7 | 1144.16 | 25 | 6.37 | 1935 | 308 | 3.44 / 1410.57 | 3 | 3 |
9 | 13 | 225.40 | 43 | 9.90 | 611 | 260 | 3.70 / 1410.83 | 2 | 3 |
10 | 8 | 0.04 | 180 | 10.75 | 268 | 519 | 4.22 / 1411.35 | 3 | 4 |
Average= | 352.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 36 | 10.81 | 416 | 162 | 0.16 / 1403.09 | 3 | 3 |
2 | 10 | 1000.48 | 3 | 8.36 | 1765 | 44 | 0.21 / 1403.13 | 3 | 3 |
3 | 3 | 1022.64 | 1 | 8.38 | 1804 | 15 | 0.22 / 1403.15 | 2 | 3 |
4 | 3 | 1022.28 | 1 | 8.44 | 1793 | 15 | 0.24 / 1403.16 | 2 | 3 |
5 | 12 | 1114.04 | 5 | 7.45 | 1907 | 71 | 0.31 / 1403.23 | 2 | 3 |
6 | 12 | 1152.04 | 68 | 7.10 | 1965 | 949 | 1.26 / 1404.18 | 2 | 3 |
7 | 12 | 1157.88 | 150 | 6.76 | 1959 | 1986 | 3.24 / 1406.17 | 3 | 3 |
8 | 7 | 1136.12 | 25 | 6.67 | 1926 | 321 | 3.56 / 1406.49 | 3 | 3 |
9 | 13 | 16.08 | 43 | 10.72 | 288 | 133 | 3.70 / 1406.62 | 3 | 3 |
10 | 8 | 0.00 | 180 | 10.79 | 263 | 511 | 4.21 / 1407.13 | 3 | 6 |
Average= | 469.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 36 | 11.40 | 439 | 180 | 0.18 / 1398.80 | 3 | 3 |
2 | 12 | 1095.92 | 5 | 8.15 | 1912 | 78 | 0.26 / 1398.88 | 2 | 3 |
3 | 12 | 1153.52 | 68 | 7.76 | 1976 | 1043 | 1.30 / 1399.92 | 2 | 3 |
4 | 12 | 1158.40 | 150 | 7.25 | 1961 | 2133 | 3.43 / 1402.05 | 3 | 3 |
5 | 7 | 1133.40 | 25 | 7.16 | 1927 | 345 | 3.78 / 1402.40 | 3 | 3 |
6 | 8 | 0.00 | 180 | 10.98 | 268 | 530 | 4.31 / 1402.93 | 3 | 3 |
Average= | 701.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 35 | 11.74 | 439 | 180 | 0.18 / 1388.79 | 3 | 3 |
2 | 3 | 1030.24 | 1 | 9.30 | 1823 | 17 | 0.20 / 1388.81 | 2 | 3 |
3 | 12 | 1103.32 | 5 | 8.97 | 1908 | 86 | 0.28 / 1388.89 | 2 | 3 |
4 | 12 | 2001.28 | 68 | 5.51 | 3345 | 1253 | 1.54 / 1390.15 | 2 | 3 |
5 | 12 | 2000.84 | 150 | 4.95 | 2837 | 2106 | 3.64 / 1392.25 | 2 | 3 |
6 | 7 | 1992.72 | 25 | 4.99 | 2915 | 364 | 4.01 / 1392.62 | 3 | 3 |
7 | 13 | 1954.36 | 43 | 5.38 | 3309 | 766 | 4.77 / 1393.38 | 2 | 3 |
8 | 13 | 1912.72 | 43 | 5.83 | 3204 | 803 | 5.58 / 1394.19 | 2 | 3 |
9 | 13 | 1843.32 | 43 | 6.28 | 3029 | 818 | 6.39 / 1395.00 | 2 | 3 |
10 | 13 | 1748.12 | 43 | 6.71 | 2858 | 825 | 7.22 / 1395.83 | 2 | 3 |
11 | 13 | 1627.56 | 43 | 7.06 | 2688 | 816 | 8.03 / 1396.64 | 2 | 3 |
12 | 13 | 1243.32 | 43 | 8.02 | 2117 | 730 | 8.76 / 1397.37 | 2 | 3 |
13 | 13 | 688.08 | 43 | 9.53 | 1308 | 536 | 9.30 / 1397.91 | 2 | 3 |
14 | 13 | 14.08 | 43 | 11.51 | 298 | 147 | 9.45 / 1398.06 | 3 | 3 |
15 | 8 | 0.12 | 180 | 11.39 | 273 | 560 | 10.01 / 1398.62 | 3 | 11 |
Average= | 1398.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 35 | 12.12 | 438 | 186 | 0.19 / 1384.36 | 3 | 3 |
2 | 3 | 1024.32 | 1 | 9.51 | 1829 | 17 | 0.20 / 1384.38 | 2 | 3 |
3 | 3 | 1019.56 | 1 | 9.37 | 1803 | 17 | 0.22 / 1384.40 | 2 | 3 |
4 | 12 | 1105.88 | 5 | 7.47 | 1891 | 71 | 0.29 / 1384.47 | 2 | 3 |
5 | 12 | 1149.48 | 68 | 7.60 | 1963 | 1014 | 1.31 / 1385.48 | 2 | 3 |
6 | 12 | 1154.32 | 150 | 7.34 | 1948 | 2145 | 3.45 / 1387.63 | 2 | 3 |
7 | 7 | 1128.76 | 24 | 8.07 | 1925 | 373 | 3.82 / 1388.00 | 3 | 3 |
8 | 8 | -0.20 | 180 | 12.15 | 279 | 610 | 4.43 / 1388.61 | 3 | 3 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 35 | 12.17 | 434 | 185 | 0.18 / 1379.52 | 3 | 3 |
2 | 12 | 1080.16 | 5 | 8.55 | 1871 | 80 | 0.26 / 1379.60 | 2 | 3 |
3 | 12 | 1149.72 | 68 | 8.18 | 1973 | 1097 | 1.36 / 1380.70 | 2 | 3 |
4 | 12 | 1154.48 | 150 | 7.83 | 1952 | 2293 | 3.65 / 1382.99 | 3 | 3 |
5 | 7 | 1126.80 | 25 | 8.40 | 1926 | 404 | 4.06 / 1383.40 | 3 | 3 |
6 | 13 | 15.48 | 43 | 12.28 | 304 | 161 | 4.22 / 1383.56 | 2 | 3 |
7 | 8 | 0.20 | 180 | 12.18 | 283 | 620 | 4.84 / 1384.18 | 3 | 8 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 32 | 12.09 | 433 | 168 | 0.17 / 1370.69 | 3 | 3 |
2 | 3 | 1060.12 | 2 | 9.36 | 1858 | 35 | 0.20 / 1370.73 | 2 | 3 |
3 | 3 | 1033.92 | 1 | 9.02 | 1857 | 17 | 0.22 / 1370.74 | 2 | 3 |
4 | 12 | 1112.80 | 5 | 9.01 | 1931 | 87 | 0.31 / 1370.83 | 2 | 3 |
5 | 12 | 2002.28 | 68 | 5.61 | 3311 | 1263 | 1.57 / 1372.09 | 2 | 3 |
6 | 12 | 2001.96 | 150 | 4.91 | 2698 | 1987 | 3.56 / 1374.08 | 2 | 3 |
7 | 7 | 1994.08 | 25 | 4.98 | 2832 | 353 | 3.91 / 1374.43 | 3 | 3 |
8 | 13 | 1948.52 | 43 | 6.98 | 3158 | 948 | 4.86 / 1375.38 | 2 | 3 |
9 | 13 | 1862.64 | 43 | 7.39 | 3018 | 959 | 5.82 / 1376.34 | 2 | 3 |
10 | 13 | 1739.64 | 43 | 7.77 | 2851 | 953 | 6.77 / 1377.29 | 2 | 3 |
11 | 13 | 1321.52 | 43 | 8.95 | 2245 | 864 | 7.63 / 1378.16 | 2 | 3 |
12 | 13 | 597.96 | 43 | 10.79 | 1191 | 553 | 8.18 / 1378.71 | 2 | 3 |
13 | 8 | 0.04 | 180 | 12.33 | 283 | 628 | 8.81 / 1379.34 | 3 | 8 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 31 | 12.14 | 427 | 161 | 0.16 / 1366.40 | 3 | 3 |
2 | 10 | 1018.52 | 3 | 9.85 | 1797 | 53 | 0.21 / 1366.45 | 2 | 3 |
3 | 3 | 1035.68 | 1 | 9.41 | 1834 | 17 | 0.23 / 1366.47 | 2 | 3 |
4 | 3 | 1021.52 | 1 | 9.32 | 1805 | 17 | 0.25 / 1366.48 | 2 | 3 |
5 | 12 | 1104.80 | 5 | 6.88 | 1885 | 65 | 0.31 / 1366.55 | 2 | 3 |
6 | 12 | 1154.44 | 68 | 6.96 | 1970 | 932 | 1.25 / 1367.48 | 2 | 3 |
7 | 12 | 1160.20 | 150 | 5.72 | 1950 | 1673 | 2.92 / 1369.15 | 2 | 3 |
8 | 7 | 1144.00 | 24 | 6.87 | 1939 | 320 | 3.24 / 1369.47 | 3 | 3 |
9 | 13 | 424.52 | 43 | 10.87 | 926 | 433 | 3.67 / 1369.91 | 2 | 3 |
10 | 8 | 0.08 | 180 | 12.25 | 280 | 617 | 4.29 / 1370.52 | 3 | 9 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 34 | 12.18 | 430 | 178 | 0.18 / 1362.13 | 3 | 3 |
2 | 12 | 1082.84 | 5 | 7.73 | 1860 | 72 | 0.25 / 1362.20 | 2 | 3 |
3 | 12 | 1163.08 | 68 | 7.07 | 1976 | 950 | 1.20 / 1363.15 | 2 | 3 |
4 | 12 | 1168.96 | 150 | 5.73 | 1966 | 1690 | 2.89 / 1364.84 | 3 | 3 |
5 | 7 | 1152.24 | 25 | 6.72 | 1944 | 327 | 3.22 / 1365.17 | 3 | 3 |
6 | 13 | 437.16 | 43 | 10.93 | 947 | 445 | 3.66 / 1365.61 | 2 | 3 |
7 | 8 | 0.08 | 180 | 12.26 | 283 | 625 | 4.29 / 1366.24 | 3 | 5 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 30 | 12.43 | 432 | 161 | 0.16 / 1357.79 | 3 | 3 |
2 | 3 | 1095.04 | 2 | 10.40 | 1948 | 41 | 0.20 / 1357.83 | 2 | 3 |
3 | 3 | 1054.36 | 1 | 10.45 | 1871 | 20 | 0.22 / 1357.85 | 2 | 3 |
4 | 12 | 1118.84 | 5 | 8.57 | 1937 | 83 | 0.30 / 1357.93 | 2 | 3 |
5 | 12 | 1150.80 | 68 | 7.77 | 1968 | 1040 | 1.34 / 1358.97 | 2 | 3 |
6 | 12 | 1155.72 | 150 | 6.34 | 1944 | 1849 | 3.19 / 1360.82 | 3 | 3 |
7 | 7 | 1132.32 | 24 | 7.34 | 1931 | 340 | 3.53 / 1361.16 | 3 | 3 |
8 | 13 | 36.28 | 43 | 12.22 | 330 | 173 | 3.71 / 1361.33 | 3 | 3 |
9 | 8 | -0.08 | 180 | 12.31 | 278 | 616 | 4.32 / 1361.95 | 3 | 3 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 30 | 12.90 | 439 | 170 | 0.17 / 1349.64 | 3 | 3 |
2 | 3 | 1052.92 | 1 | 11.04 | 1893 | 21 | 0.19 / 1349.66 | 2 | 3 |
3 | 3 | 1028.80 | 1 | 10.85 | 1868 | 20 | 0.21 / 1349.68 | 2 | 3 |
4 | 12 | 1102.28 | 5 | 10.84 | 1959 | 106 | 0.32 / 1349.78 | 2 | 3 |
5 | 12 | 2001.64 | 68 | 6.96 | 3300 | 1562 | 1.88 / 1351.35 | 2 | 3 |
6 | 12 | 1999.08 | 150 | 5.01 | 2732 | 2053 | 3.93 / 1353.40 | 2 | 3 |
7 | 7 | 1981.40 | 25 | 5.97 | 3235 | 483 | 4.41 / 1353.88 | 3 | 3 |
8 | 13 | 1876.88 | 43 | 8.51 | 3051 | 1116 | 5.53 / 1355.00 | 2 | 3 |
9 | 13 | 1493.64 | 43 | 9.49 | 2504 | 1022 | 6.55 / 1356.02 | 2 | 3 |
10 | 13 | 919.72 | 43 | 10.60 | 1675 | 763 | 7.32 / 1356.78 | 2 | 3 |
11 | 13 | 54.48 | 43 | 12.43 | 371 | 198 | 7.52 / 1356.98 | 3 | 3 |
12 | 8 | 0.00 | 180 | 12.48 | 288 | 647 | 8.16 / 1357.63 | 3 | 5 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 30 | 13.31 | 442 | 176 | 0.18 / 1344.25 | 3 | 3 |
2 | 3 | 1034.72 | 1 | 11.33 | 1866 | 21 | 0.20 / 1344.27 | 2 | 3 |
3 | 3 | 1020.48 | 1 | 10.95 | 1832 | 20 | 0.22 / 1344.29 | 2 | 3 |
4 | 12 | 1107.76 | 5 | 4.79 | 1704 | 41 | 0.26 / 1344.33 | 2 | 3 |
5 | 12 | 1151.68 | 68 | 5.04 | 1941 | 665 | 0.92 / 1345.00 | 2 | 3 |
6 | 12 | 1158.28 | 150 | 4.89 | 1808 | 1326 | 2.25 / 1346.32 | 3 | 3 |
7 | 7 | 1174.48 | 25 | 7.74 | 2023 | 391 | 2.64 / 1346.71 | 3 | 3 |
8 | 13 | 1227.64 | 43 | 8.47 | 2094 | 763 | 3.40 / 1347.48 | 2 | 3 |
9 | 13 | 1132.36 | 43 | 9.05 | 1955 | 761 | 4.16 / 1348.24 | 2 | 3 |
10 | 13 | 591.32 | 43 | 11.09 | 1178 | 562 | 4.73 / 1348.80 | 2 | 3 |
11 | 8 | -0.08 | 180 | 12.81 | 289 | 666 | 5.39 / 1349.47 | 3 | 16 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 30 | 13.51 | 447 | 181 | 0.18 / 1338.90 | 3 | 3 |
2 | 12 | 1090.12 | 5 | 4.82 | 1824 | 44 | 0.23 / 1338.94 | 2 | 3 |
3 | 12 | 1150.16 | 68 | 5.30 | 1954 | 704 | 0.93 / 1339.65 | 2 | 3 |
4 | 12 | 1156.92 | 150 | 4.94 | 1930 | 1430 | 2.36 / 1341.08 | 2 | 3 |
5 | 7 | 1169.48 | 25 | 8.25 | 2016 | 416 | 2.78 / 1341.49 | 3 | 3 |
6 | 13 | 1134.72 | 43 | 9.21 | 1962 | 777 | 3.55 / 1342.27 | 2 | 3 |
7 | 13 | 1010.52 | 43 | 9.82 | 1792 | 757 | 4.31 / 1343.03 | 2 | 3 |
8 | 13 | 238.32 | 43 | 12.45 | 663 | 355 | 4.66 / 1343.38 | 2 | 3 |
9 | 8 | 0.24 | 180 | 13.07 | 294 | 692 | 5.36 / 1344.07 | 3 | 5 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 30 | 13.66 | 441 | 181 | 0.18 / 1334.49 | 3 | 3 |
2 | 3 | 1018.88 | 1 | 11.04 | 1848 | 20 | 0.20 / 1334.51 | 2 | 3 |
3 | 12 | 1101.64 | 5 | 6.61 | 1902 | 63 | 0.26 / 1334.57 | 2 | 3 |
4 | 12 | 1152.68 | 68 | 6.73 | 1966 | 900 | 1.16 / 1335.47 | 2 | 3 |
5 | 12 | 1158.04 | 150 | 6.27 | 1956 | 1840 | 3.00 / 1337.31 | 2 | 3 |
6 | 7 | 1139.84 | 25 | 9.02 | 1969 | 444 | 3.45 / 1337.75 | 3 | 3 |
7 | 13 | 99.84 | 43 | 13.30 | 450 | 257 | 3.70 / 1338.01 | 3 | 3 |
8 | 8 | 0.12 | 180 | 13.43 | 293 | 708 | 4.41 / 1338.72 | 3 | 8 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 29 | 13.76 | 440 | 176 | 0.18 / 1326.86 | 3 | 3 |
2 | 3 | 1032.16 | 1 | 11.20 | 1869 | 21 | 0.20 / 1326.88 | 2 | 3 |
3 | 12 | 1101.48 | 5 | 10.95 | 1949 | 107 | 0.30 / 1326.99 | 2 | 3 |
4 | 12 | 1990.04 | 68 | 7.68 | 3238 | 1691 | 1.99 / 1328.68 | 2 | 3 |
5 | 12 | 1986.96 | 150 | 5.45 | 3004 | 2456 | 4.45 / 1331.14 | 2 | 3 |
6 | 7 | 1963.64 | 25 | 8.06 | 3215 | 648 | 5.10 / 1331.79 | 3 | 3 |
7 | 13 | 1435.92 | 43 | 10.85 | 2452 | 1144 | 6.24 / 1332.93 | 2 | 3 |
8 | 13 | 565.76 | 43 | 12.68 | 1169 | 637 | 6.88 / 1333.57 | 2 | 3 |
9 | 8 | 0.00 | 180 | 13.62 | 301 | 738 | 7.62 / 1334.30 | 3 | 4 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 30 | 13.92 | 454 | 190 | 0.19 / 1321.31 | 3 | 3 |
2 | 12 | 1102.52 | 5 | 4.77 | 1650 | 39 | 0.23 / 1321.35 | 2 | 3 |
3 | 12 | 1153.80 | 68 | 4.97 | 1910 | 646 | 0.87 / 1322.00 | 2 | 3 |
4 | 12 | 1161.24 | 150 | 4.88 | 1815 | 1329 | 2.20 / 1323.32 | 2 | 3 |
5 | 7 | 1180.16 | 25 | 8.41 | 2031 | 427 | 2.63 / 1323.75 | 3 | 3 |
6 | 13 | 1230.08 | 43 | 9.23 | 2105 | 835 | 3.47 / 1324.59 | 2 | 3 |
7 | 13 | 1132.76 | 43 | 10.00 | 1968 | 846 | 4.31 / 1325.43 | 2 | 3 |
8 | 13 | 413.52 | 43 | 12.75 | 930 | 510 | 4.82 / 1325.94 | 2 | 3 |
9 | 8 | -0.08 | 180 | 13.74 | 301 | 744 | 5.57 / 1326.69 | 3 | 5 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 30 | 14.06 | 440 | 186 | 0.19 / 1316.28 | 3 | 3 |
2 | 12 | 1075.84 | 5 | 4.79 | 1700 | 41 | 0.23 / 1316.32 | 2 | 3 |
3 | 12 | 1150.60 | 68 | 5.34 | 1947 | 707 | 0.93 / 1317.02 | 2 | 3 |
4 | 12 | 1157.16 | 150 | 5.26 | 1958 | 1545 | 2.48 / 1318.57 | 2 | 3 |
5 | 7 | 1162.12 | 25 | 9.02 | 2000 | 451 | 2.93 / 1319.02 | 3 | 3 |
6 | 13 | 1053.48 | 43 | 10.07 | 1852 | 802 | 3.73 / 1319.82 | 2 | 3 |
7 | 13 | 465.40 | 43 | 12.66 | 1008 | 549 | 4.28 / 1320.37 | 2 | 3 |
8 | 8 | 0.08 | 180 | 13.89 | 300 | 750 | 5.03 / 1321.12 | 3 | 3 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 30 | 14.21 | 446 | 190 | 0.19 / 1311.73 | 3 | 3 |
2 | 3 | 969.48 | -1 | 14.21 | 446 | 0 | 0.00 / 1311.73 | 3 | 3 |
3 | 3 | 1041.12 | 1 | 11.32 | 1890 | 21 | 0.21 / 1311.75 | 2 | 3 |
4 | 12 | 1109.56 | 5 | 4.86 | 2025 | 49 | 0.26 / 1311.80 | 2 | 3 |
5 | 12 | 1153.92 | 68 | 6.71 | 1957 | 893 | 1.15 / 1312.69 | 2 | 3 |
6 | 12 | 1159.36 | 150 | 6.49 | 1956 | 1904 | 3.06 / 1314.60 | 2 | 3 |
7 | 7 | 1140.56 | 25 | 9.62 | 1971 | 474 | 3.53 / 1315.07 | 3 | 3 |
8 | 13 | 83.28 | 43 | 13.91 | 432 | 258 | 3.79 / 1315.33 | 2 | 3 |
9 | 8 | 0.00 | 180 | 14.05 | 301 | 761 | 4.55 / 1316.09 | 3 | 6 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 30 | 14.08 | 453 | 191 | 0.19 / 1303.47 | 3 | 3 |
2 | 3 | 955.08 | -1 | 14.08 | 453 | 0 | 0.00 / 1303.47 | 3 | 3 |
3 | 3 | 1018.80 | 1 | 10.64 | 1847 | 20 | 0.21 / 1303.49 | 2 | 2 |
4 | 12 | 1108.88 | 5 | 11.06 | 1958 | 108 | 0.32 / 1303.59 | 2 | 3 |
5 | 12 | 2003.60 | 68 | 6.79 | 3285 | 1517 | 1.84 / 1305.11 | 2 | 3 |
6 | 12 | 2000.64 | 150 | 5.40 | 3005 | 2434 | 4.27 / 1307.55 | 2 | 3 |
7 | 7 | 1980.92 | 25 | 8.92 | 3219 | 718 | 4.99 / 1308.26 | 3 | 3 |
8 | 13 | 1722.64 | 43 | 10.60 | 2862 | 1304 | 6.29 / 1309.57 | 2 | 3 |
9 | 13 | 983.08 | 43 | 12.43 | 1753 | 937 | 7.23 / 1310.50 | 2 | 3 |
10 | 13 | 67.56 | 43 | 14.10 | 417 | 253 | 7.48 / 1310.76 | 2 | 3 |
11 | 8 | -0.08 | 180 | 14.21 | 306 | 783 | 8.26 / 1311.54 | 3 | 12 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 30 | 14.09 | 442 | 187 | 0.19 / 1298.56 | 3 | 3 |
2 | 12 | 1074.96 | 5 | 4.76 | 1597 | 38 | 0.22 / 1298.59 | 2 | 3 |
3 | 12 | 1153.80 | 68 | 5.26 | 1952 | 698 | 0.92 / 1299.29 | 2 | 3 |
4 | 12 | 1160.00 | 150 | 5.23 | 1960 | 1538 | 2.46 / 1300.83 | 2 | 3 |
5 | 7 | 1164.04 | 25 | 9.10 | 2005 | 456 | 2.92 / 1301.29 | 3 | 3 |
6 | 13 | 1051.60 | 43 | 10.57 | 1860 | 845 | 3.76 / 1302.13 | 2 | 3 |
7 | 13 | 192.84 | 43 | 13.67 | 608 | 357 | 4.12 / 1302.49 | 2 | 3 |
8 | 8 | -0.08 | 180 | 14.14 | 309 | 786 | 4.91 / 1303.28 | 3 | 8 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 30 | 14.13 | 458 | 194 | 0.19 / 1293.95 | 3 | 3 |
2 | 12 | 1089.36 | 5 | 4.79 | 1736 | 42 | 0.24 / 1293.99 | 2 | 3 |
3 | 12 | 1158.92 | 68 | 5.91 | 1963 | 789 | 1.02 / 1294.78 | 2 | 3 |
4 | 12 | 1165.36 | 150 | 5.85 | 1972 | 1730 | 2.76 / 1296.51 | 3 | 3 |
5 | 7 | 1154.16 | 25 | 9.30 | 1986 | 462 | 3.22 / 1296.97 | 3 | 3 |
6 | 13 | 566.16 | 43 | 12.65 | 1161 | 632 | 3.85 / 1297.60 | 2 | 3 |
7 | 8 | 0.28 | 180 | 14.16 | 301 | 767 | 4.62 / 1298.37 | 3 | 6 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 30 | 14.19 | 447 | 190 | 0.19 / 1289.31 | 3 | 3 |
2 | 12 | 1077.68 | 5 | 5.02 | 2038 | 51 | 0.24 / 1289.36 | 2 | 3 |
3 | 12 | 1147.08 | 68 | 7.00 | 1963 | 934 | 1.18 / 1290.30 | 2 | 3 |
4 | 12 | 1152.80 | 150 | 6.84 | 1958 | 2009 | 3.18 / 1292.31 | 2 | 3 |
5 | 7 | 1132.52 | 25 | 9.79 | 1964 | 481 | 3.67 / 1292.79 | 3 | 3 |
6 | 13 | 25.08 | 43 | 14.15 | 339 | 206 | 3.87 / 1292.99 | 3 | 3 |
7 | 8 | -0.20 | 180 | 14.23 | 297 | 761 | 4.63 / 1293.75 | 3 | 14 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 30 | 14.13 | 448 | 190 | 0.19 / 1280.90 | 3 | 3 |
2 | 12 | 1098.76 | 5 | 10.94 | 1960 | 107 | 0.30 / 1281.00 | 2 | 3 |
3 | 12 | 2001.60 | 68 | 6.50 | 3270 | 1445 | 1.74 / 1282.45 | 2 | 3 |
4 | 12 | 1999.48 | 150 | 5.39 | 3112 | 2516 | 4.26 / 1284.96 | 2 | 3 |
5 | 7 | 1982.64 | 25 | 9.13 | 3244 | 740 | 5.00 / 1285.71 | 3 | 3 |
6 | 13 | 1852.76 | 43 | 10.37 | 3040 | 1356 | 6.35 / 1287.06 | 2 | 3 |
7 | 13 | 1109.48 | 43 | 12.41 | 1938 | 1034 | 7.39 / 1288.09 | 2 | 3 |
8 | 13 | 71.56 | 43 | 14.14 | 415 | 252 | 7.64 / 1288.35 | 3 | 3 |
9 | 8 | -0.08 | 180 | 14.29 | 301 | 774 | 8.42 / 1289.12 | 3 | 16 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 30 | 14.11 | 445 | 188 | 0.19 / 1276.24 | 3 | 3 |
2 | 12 | 1092.88 | 5 | 4.79 | 1723 | 41 | 0.23 / 1276.28 | 2 | 3 |
3 | 12 | 1156.76 | 68 | 5.99 | 1968 | 802 | 1.03 / 1277.08 | 2 | 3 |
4 | 12 | 1163.32 | 150 | 5.97 | 1969 | 1763 | 2.79 / 1278.84 | 3 | 3 |
5 | 7 | 1151.24 | 25 | 9.43 | 1992 | 470 | 3.26 / 1279.31 | 3 | 3 |
6 | 13 | 278.00 | 43 | 13.52 | 738 | 429 | 3.69 / 1279.74 | 2 | 3 |
7 | 13 | 8.44 | 43 | 14.17 | 314 | 191 | 3.88 / 1279.93 | 3 | 7 |
8 | 8 | -0.28 | 180 | 14.21 | 302 | 772 | 4.66 / 1280.71 | 3 | 16 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 30 | 14.14 | 447 | 190 | 0.19 / 1271.77 | 3 | 3 |
2 | 12 | 1098.92 | 5 | 4.82 | 1833 | 44 | 0.23 / 1271.82 | 2 | 3 |
3 | 12 | 1153.52 | 68 | 6.49 | 1962 | 866 | 1.10 / 1272.68 | 2 | 3 |
4 | 12 | 1159.60 | 150 | 6.42 | 1966 | 1893 | 2.99 / 1274.58 | 3 | 3 |
5 | 7 | 1142.68 | 25 | 9.55 | 1978 | 472 | 3.47 / 1275.05 | 3 | 3 |
6 | 13 | 49.36 | 43 | 14.08 | 378 | 229 | 3.69 / 1275.28 | 3 | 3 |
7 | 8 | 0.08 | 180 | 14.22 | 301 | 770 | 4.46 / 1276.05 | 3 | 9 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 30 | 14.22 | 441 | 188 | 0.19 / 1266.98 | 3 | 3 |
2 | 12 | 1071.68 | 5 | 5.50 | 1929 | 53 | 0.24 / 1267.03 | 2 | 3 |
3 | 12 | 1157.72 | 68 | 7.16 | 1974 | 961 | 1.20 / 1267.99 | 2 | 3 |
4 | 12 | 1163.08 | 150 | 7.18 | 1972 | 2124 | 3.33 / 1270.12 | 2 | 3 |
5 | 7 | 1140.16 | 25 | 9.93 | 1979 | 491 | 3.82 / 1270.61 | 3 | 3 |
6 | 13 | 20.48 | 43 | 14.17 | 333 | 203 | 4.02 / 1270.81 | 2 | 3 |
7 | 8 | 0.04 | 180 | 14.23 | 302 | 774 | 4.79 / 1271.58 | 3 | 14 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 30 | 14.17 | 444 | 189 | 0.19 / 1258.46 | 3 | 3 |
2 | 12 | 1083.08 | 5 | 11.00 | 1927 | 106 | 0.29 / 1258.57 | 2 | 3 |
3 | 12 | 2001.68 | 68 | 6.82 | 3285 | 1523 | 1.82 / 1260.09 | 2 | 3 |
4 | 12 | 1999.00 | 150 | 5.48 | 3285 | 2700 | 4.52 / 1262.79 | 2 | 3 |
5 | 7 | 1979.44 | 25 | 9.47 | 3256 | 771 | 5.29 / 1263.56 | 3 | 3 |
6 | 13 | 1716.92 | 43 | 11.31 | 2865 | 1393 | 6.68 / 1264.96 | 2 | 3 |
7 | 13 | 814.96 | 43 | 13.02 | 1511 | 846 | 7.53 / 1265.80 | 2 | 3 |
8 | 13 | 24.12 | 43 | 14.23 | 342 | 209 | 7.74 / 1266.01 | 3 | 3 |
9 | 8 | -0.04 | 180 | 14.31 | 303 | 780 | 8.52 / 1266.79 | 3 | 15 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 30 | 14.13 | 441 | 187 | 0.19 / 1253.95 | 3 | 3 |
2 | 12 | 1098.28 | 5 | 4.80 | 1763 | 42 | 0.23 / 1253.99 | 2 | 3 |
3 | 12 | 1156.72 | 68 | 6.55 | 1964 | 875 | 1.10 / 1254.87 | 2 | 3 |
4 | 12 | 1163.28 | 150 | 6.63 | 1962 | 1951 | 3.06 / 1256.82 | 3 | 3 |
5 | 7 | 1147.16 | 25 | 9.75 | 1984 | 484 | 3.54 / 1257.30 | 3 | 3 |
6 | 13 | 42.80 | 43 | 14.13 | 362 | 220 | 3.76 / 1257.52 | 3 | 3 |
7 | 8 | -0.08 | 180 | 14.25 | 292 | 749 | 4.51 / 1258.27 | 3 | 14 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 30 | 14.13 | 444 | 188 | 0.19 / 1249.36 | 3 | 3 |
2 | 12 | 1104.12 | 5 | 4.82 | 1844 | 44 | 0.23 / 1249.40 | 2 | 3 |
3 | 12 | 1151.72 | 68 | 6.84 | 1956 | 910 | 1.14 / 1250.31 | 2 | 3 |
4 | 12 | 1157.28 | 150 | 6.84 | 1956 | 2007 | 3.15 / 1252.32 | 2 | 3 |
5 | 7 | 1136.60 | 25 | 9.76 | 1966 | 480 | 3.63 / 1252.80 | 3 | 3 |
6 | 13 | 30.48 | 43 | 14.14 | 342 | 208 | 3.84 / 1253.01 | 3 | 3 |
7 | 8 | -0.16 | 180 | 14.24 | 296 | 759 | 4.60 / 1253.76 | 3 | 12 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 30 | 14.24 | 447 | 191 | 0.19 / 1244.48 | 3 | 3 |
2 | 12 | 1086.04 | 5 | 4.87 | 2082 | 51 | 0.24 / 1244.53 | 2 | 3 |
3 | 12 | 1159.72 | 68 | 7.32 | 1981 | 986 | 1.23 / 1245.52 | 2 | 3 |
4 | 12 | 1165.56 | 150 | 7.38 | 1972 | 2183 | 3.41 / 1247.70 | 2 | 3 |
5 | 7 | 1143.52 | 25 | 10.07 | 1982 | 499 | 3.91 / 1248.20 | 3 | 3 |
6 | 13 | 15.56 | 43 | 14.19 | 321 | 196 | 4.11 / 1248.40 | 2 | 3 |
7 | 8 | -0.04 | 180 | 14.24 | 301 | 772 | 4.88 / 1249.17 | 3 | 14 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 30 | 14.15 | 440 | 187 | 0.19 / 1235.97 | 3 | 3 |
2 | 12 | 1076.36 | 5 | 10.99 | 1925 | 106 | 0.29 / 1236.07 | 2 | 3 |
3 | 12 | 2000.56 | 68 | 6.69 | 3299 | 1501 | 1.79 / 1237.57 | 2 | 3 |
4 | 12 | 1997.92 | 150 | 5.66 | 3378 | 2868 | 4.66 / 1240.44 | 2 | 3 |
5 | 7 | 1977.72 | 25 | 9.86 | 3235 | 797 | 5.46 / 1241.24 | 3 | 3 |
6 | 13 | 1554.12 | 43 | 11.86 | 2638 | 1345 | 6.80 / 1242.58 | 2 | 3 |
7 | 13 | 654.80 | 43 | 13.32 | 1282 | 734 | 7.54 / 1243.32 | 2 | 3 |
8 | 13 | 4.36 | 43 | 14.27 | 309 | 190 | 7.73 / 1243.51 | 3 | 3 |
9 | 8 | -0.08 | 180 | 14.30 | 305 | 785 | 8.51 / 1244.29 | 3 | 18 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 30 | 14.12 | 451 | 191 | 0.19 / 1231.43 | 3 | 3 |
2 | 12 | 1093.60 | 5 | 4.78 | 1675 | 40 | 0.23 / 1231.47 | 2 | 3 |
3 | 12 | 1165.44 | 68 | 5.88 | 1985 | 794 | 1.02 / 1232.26 | 2 | 3 |
4 | 12 | 1172.92 | 150 | 6.23 | 1989 | 1859 | 2.88 / 1234.12 | 2 | 3 |
5 | 7 | 1162.68 | 25 | 9.70 | 2018 | 489 | 3.37 / 1234.61 | 3 | 3 |
6 | 13 | 240.00 | 43 | 13.72 | 682 | 402 | 3.78 / 1235.01 | 2 | 3 |
7 | 8 | 0.08 | 180 | 14.24 | 300 | 769 | 4.54 / 1235.78 | 3 | 7 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 29 | 14.13 | 444 | 182 | 0.18 / 1227.06 | 3 | 3 |
2 | 12 | 1095.32 | 5 | 4.81 | 1796 | 43 | 0.23 / 1227.10 | 2 | 3 |
3 | 12 | 1156.52 | 25 | 6.68 | 1968 | 329 | 0.55 / 1227.43 | 2 | 3 |
4 | 12 | 1159.40 | 150 | 6.51 | 1970 | 1924 | 2.48 / 1229.36 | 2 | 3 |
5 | 7 | 1151.40 | 25 | 9.61 | 1986 | 477 | 2.95 / 1229.83 | 3 | 3 |
6 | 13 | 559.16 | 43 | 12.95 | 1149 | 640 | 3.59 / 1230.47 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.22 | 298 | 763 | 4.36 / 1231.23 | 2 | 5 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 29 | 14.21 | 445 | 183 | 0.18 / 1222.79 | 3 | 3 |
2 | 12 | 1088.76 | 5 | 4.86 | 2036 | 49 | 0.23 / 1222.84 | 2 | 3 |
3 | 12 | 1155.96 | 25 | 7.23 | 1980 | 358 | 0.59 / 1223.20 | 2 | 3 |
4 | 12 | 1159.04 | 150 | 7.22 | 1971 | 2135 | 2.73 / 1225.33 | 2 | 3 |
5 | 7 | 1148.68 | 25 | 9.90 | 1989 | 492 | 3.22 / 1225.83 | 3 | 3 |
6 | 13 | 109.28 | 43 | 14.01 | 470 | 283 | 3.50 / 1226.11 | 3 | 3 |
7 | 8 | -0.16 | 180 | 14.24 | 300 | 769 | 4.27 / 1226.88 | 3 | 11 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 29 | 14.07 | 447 | 182 | 0.18 / 1214.71 | 3 | 3 |
2 | 3 | 1019.32 | 1 | 10.37 | 1841 | 19 | 0.20 / 1214.73 | 2 | 3 |
3 | 12 | 1097.12 | 5 | 10.96 | 1952 | 107 | 0.31 / 1214.84 | 2 | 3 |
4 | 12 | 2002.36 | 25 | 8.25 | 3261 | 673 | 0.98 / 1215.51 | 2 | 3 |
5 | 12 | 2002.36 | 150 | 5.54 | 3380 | 2809 | 3.79 / 1218.32 | 2 | 3 |
6 | 7 | 1986.60 | 25 | 9.86 | 3263 | 804 | 4.59 / 1219.12 | 3 | 3 |
7 | 13 | 1855.52 | 43 | 11.15 | 3074 | 1474 | 6.07 / 1220.60 | 2 | 3 |
8 | 13 | 1068.68 | 43 | 12.72 | 1879 | 1028 | 7.10 / 1221.62 | 2 | 3 |
9 | 13 | 22.92 | 43 | 14.22 | 337 | 206 | 7.30 / 1221.83 | 2 | 3 |
10 | 8 | 0.04 | 180 | 14.31 | 302 | 778 | 8.08 / 1222.61 | 3 | 11 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 29 | 14.07 | 448 | 183 | 0.18 / 1210.46 | 3 | 3 |
2 | 12 | 1096.60 | 5 | 4.79 | 1717 | 41 | 0.22 / 1210.50 | 2 | 3 |
3 | 12 | 1152.84 | 25 | 6.50 | 1962 | 319 | 0.54 / 1210.82 | 2 | 3 |
4 | 12 | 1155.68 | 150 | 6.52 | 1962 | 1919 | 2.46 / 1212.74 | 2 | 3 |
5 | 7 | 1147.36 | 25 | 9.73 | 1992 | 485 | 2.95 / 1213.22 | 3 | 3 |
6 | 13 | 409.72 | 43 | 13.35 | 935 | 537 | 3.48 / 1213.76 | 2 | 3 |
7 | 8 | 0.16 | 180 | 14.22 | 301 | 770 | 4.25 / 1214.53 | 3 | 8 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 29 | 14.11 | 449 | 184 | 0.18 / 1206.18 | 3 | 3 |
2 | 12 | 1086.44 | 5 | 4.82 | 1859 | 45 | 0.23 / 1206.23 | 2 | 3 |
3 | 12 | 1159.00 | 25 | 6.88 | 1977 | 340 | 0.57 / 1206.57 | 2 | 3 |
4 | 12 | 1162.16 | 150 | 6.85 | 1978 | 2032 | 2.60 / 1208.60 | 2 | 3 |
5 | 7 | 1154.72 | 25 | 9.80 | 1996 | 489 | 3.09 / 1209.09 | 3 | 3 |
6 | 13 | 262.08 | 43 | 13.64 | 712 | 418 | 3.51 / 1209.51 | 3 | 3 |
7 | 8 | -0.16 | 180 | 14.20 | 300 | 767 | 4.27 / 1210.27 | 3 | 8 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 29 | 14.16 | 454 | 186 | 0.19 / 1201.82 | 3 | 3 |
2 | 12 | 1077.96 | 5 | 4.88 | 2086 | 51 | 0.24 / 1201.87 | 2 | 3 |
3 | 12 | 1152.80 | 25 | 7.60 | 1974 | 375 | 0.61 / 1202.25 | 2 | 3 |
4 | 12 | 1155.44 | 150 | 7.59 | 1970 | 2243 | 2.86 / 1204.49 | 2 | 3 |
5 | 7 | 1140.64 | 25 | 10.06 | 1982 | 498 | 3.35 / 1204.99 | 3 | 3 |
6 | 13 | 70.56 | 43 | 14.06 | 409 | 247 | 3.60 / 1205.24 | 3 | 3 |
7 | 8 | 0.12 | 180 | 14.22 | 299 | 765 | 4.37 / 1206.00 | 3 | 10 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 29 | 14.06 | 452 | 184 | 0.18 / 1194.31 | 3 | 3 |
2 | 12 | 1098.68 | 5 | 10.92 | 1961 | 107 | 0.29 / 1194.42 | 2 | 3 |
3 | 12 | 2001.20 | 25 | 8.38 | 3250 | 681 | 0.97 / 1195.10 | 2 | 3 |
4 | 12 | 2000.96 | 150 | 6.07 | 3370 | 3068 | 4.04 / 1198.17 | 2 | 3 |
5 | 7 | 1981.76 | 25 | 9.98 | 3259 | 813 | 4.85 / 1198.98 | 3 | 3 |
6 | 13 | 1431.04 | 43 | 12.18 | 2390 | 1252 | 6.11 / 1200.23 | 2 | 3 |
7 | 13 | 511.16 | 43 | 13.53 | 1079 | 628 | 6.73 / 1200.86 | 2 | 3 |
8 | 8 | -0.04 | 180 | 14.30 | 300 | 772 | 7.51 / 1201.63 | 3 | 7 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 29 | 14.07 | 450 | 184 | 0.18 / 1190.09 | 3 | 3 |
2 | 12 | 1084.96 | 5 | 4.79 | 1742 | 42 | 0.23 / 1190.13 | 2 | 3 |
3 | 12 | 1157.92 | 25 | 6.67 | 1969 | 328 | 0.55 / 1190.46 | 2 | 3 |
4 | 12 | 1160.96 | 150 | 6.72 | 1967 | 1983 | 2.54 / 1192.44 | 2 | 3 |
5 | 7 | 1153.52 | 25 | 9.83 | 1998 | 491 | 3.03 / 1192.93 | 3 | 3 |
6 | 13 | 279.16 | 43 | 13.64 | 736 | 432 | 3.46 / 1193.36 | 2 | 3 |
7 | 8 | 0.04 | 180 | 14.21 | 300 | 767 | 4.23 / 1194.13 | 3 | 8 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 29 | 14.07 | 450 | 184 | 0.18 / 1185.84 | 3 | 3 |
2 | 12 | 1096.84 | 5 | 4.81 | 1815 | 44 | 0.23 / 1185.88 | 2 | 3 |
3 | 12 | 1153.88 | 25 | 6.73 | 1960 | 330 | 0.56 / 1186.21 | 2 | 3 |
4 | 12 | 1156.76 | 150 | 6.88 | 1964 | 2027 | 2.58 / 1188.24 | 2 | 3 |
5 | 7 | 1147.64 | 25 | 9.80 | 1987 | 487 | 3.07 / 1188.73 | 3 | 3 |
6 | 13 | 259.96 | 43 | 13.66 | 705 | 414 | 3.48 / 1189.14 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.20 | 298 | 762 | 4.25 / 1189.90 | 3 | 7 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 29 | 14.15 | 454 | 186 | 0.19 / 1181.89 | 3 | 3 |
2 | 12 | 1104.76 | 150 | 7.51 | 1896 | 2136 | 2.32 / 1184.02 | 2 | 3 |
3 | 7 | 1100.16 | 25 | 10.12 | 1921 | 486 | 2.81 / 1184.51 | 3 | 3 |
4 | 13 | 210.96 | 43 | 13.76 | 634 | 375 | 3.18 / 1184.88 | 2 | 3 |
5 | 8 | 0.12 | 180 | 14.19 | 302 | 771 | 3.95 / 1185.66 | 3 | 7 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 29 | 14.05 | 443 | 181 | 0.18 / 1174.95 | 3 | 3 |
2 | 12 | 1119.52 | 5 | 10.94 | 1976 | 108 | 0.29 / 1175.06 | 2 | 3 |
3 | 12 | 2003.04 | 150 | 6.65 | 3340 | 3332 | 3.62 / 1178.39 | 2 | 3 |
4 | 7 | 1986.68 | 24 | 10.19 | 3260 | 797 | 4.42 / 1179.19 | 3 | 3 |
5 | 13 | 1407.68 | 43 | 12.27 | 2372 | 1251 | 5.67 / 1180.44 | 2 | 3 |
6 | 13 | 312.20 | 43 | 13.78 | 798 | 473 | 6.14 / 1180.91 | 2 | 3 |
7 | 8 | 0.04 | 180 | 14.28 | 307 | 789 | 6.93 / 1181.70 | 3 | 8 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 29 | 14.05 | 459 | 187 | 0.19 / 1170.65 | 3 | 3 |
2 | 12 | 1136.24 | 150 | 6.19 | 1932 | 1794 | 1.98 / 1172.45 | 2 | 3 |
3 | 7 | 1141.16 | 25 | 9.86 | 1985 | 489 | 2.47 / 1172.94 | 3 | 3 |
4 | 13 | 879.32 | 43 | 12.24 | 1632 | 859 | 3.33 / 1173.80 | 2 | 3 |
5 | 13 | 21.76 | 43 | 14.15 | 332 | 202 | 3.53 / 1174.00 | 3 | 3 |
6 | 8 | -0.04 | 180 | 14.20 | 302 | 772 | 4.30 / 1174.77 | 3 | 13 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 29 | 14.08 | 450 | 184 | 0.18 / 1166.60 | 3 | 3 |
2 | 12 | 1123.04 | 150 | 6.78 | 1916 | 1949 | 2.13 / 1168.55 | 2 | 3 |
3 | 7 | 1123.28 | 25 | 10.02 | 1959 | 491 | 2.62 / 1169.04 | 3 | 3 |
4 | 13 | 571.20 | 43 | 13.04 | 1176 | 659 | 3.28 / 1169.70 | 2 | 3 |
5 | 8 | -0.04 | 180 | 14.20 | 301 | 769 | 4.05 / 1170.47 | 3 | 6 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 29 | 14.12 | 443 | 181 | 0.18 / 1162.54 | 3 | 3 |
2 | 12 | 1112.96 | 150 | 7.79 | 1918 | 2241 | 2.42 / 1164.79 | 2 | 3 |
3 | 7 | 1109.00 | 25 | 10.34 | 1936 | 500 | 2.92 / 1165.29 | 3 | 3 |
4 | 13 | 184.80 | 43 | 13.82 | 590 | 351 | 3.27 / 1165.64 | 2 | 3 |
5 | 8 | -0.04 | 180 | 14.18 | 305 | 778 | 4.05 / 1166.42 | 3 | 8 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 29 | 14.08 | 444 | 181 | 0.18 / 1155.81 | 3 | 3 |
2 | 3 | 966.32 | -1 | 14.08 | 444 | 0 | 0.00 / 1155.81 | 3 | 3 |
3 | 3 | 1035.80 | 1 | 10.69 | 1860 | 20 | 0.20 / 1155.83 | 2 | 3 |
4 | 12 | 1135.80 | 5 | 10.96 | 2005 | 110 | 0.31 / 1155.94 | 2 | 3 |
5 | 12 | 2003.52 | 150 | 7.23 | 3265 | 3541 | 3.85 / 1159.48 | 2 | 3 |
6 | 7 | 1985.76 | 25 | 10.27 | 3246 | 833 | 4.69 / 1160.32 | 3 | 3 |
7 | 13 | 1067.76 | 43 | 12.73 | 1919 | 1050 | 5.74 / 1161.37 | 2 | 3 |
8 | 13 | 28.60 | 43 | 14.21 | 346 | 211 | 5.95 / 1161.58 | 3 | 3 |
9 | 8 | 0.04 | 180 | 14.29 | 305 | 785 | 6.73 / 1162.36 | 3 | 8 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 28 | 14.06 | 447 | 176 | 0.18 / 1151.43 | 3 | 3 |
2 | 3 | 1019.72 | 1 | 10.48 | 1851 | 19 | 0.20 / 1151.45 | 2 | 3 |
3 | 12 | 1139.80 | 150 | 6.37 | 1931 | 1845 | 2.04 / 1153.30 | 2 | 3 |
4 | 7 | 1144.76 | 25 | 10.07 | 1986 | 500 | 2.54 / 1153.80 | 3 | 3 |
5 | 13 | 871.92 | 43 | 12.38 | 1620 | 862 | 3.40 / 1154.66 | 2 | 3 |
6 | 13 | 16.00 | 43 | 14.14 | 327 | 199 | 3.60 / 1154.86 | 3 | 3 |
7 | 8 | -0.16 | 180 | 14.19 | 303 | 774 | 4.38 / 1155.63 | 3 | 12 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 29 | 14.05 | 452 | 184 | 0.18 / 1147.33 | 3 | 3 |
2 | 12 | 1126.92 | 150 | 6.95 | 1924 | 2006 | 2.19 / 1149.34 | 2 | 3 |
3 | 7 | 1124.76 | 25 | 10.12 | 1961 | 496 | 2.69 / 1149.83 | 3 | 3 |
4 | 13 | 551.44 | 43 | 13.14 | 1148 | 649 | 3.33 / 1150.48 | 2 | 3 |
5 | 8 | 0.16 | 180 | 14.18 | 304 | 776 | 4.11 / 1151.26 | 3 | 7 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 30 | 14.14 | 455 | 193 | 0.19 / 1143.17 | 3 | 3 |
2 | 3 | 956.76 | -1 | 14.14 | 455 | 0 | 0.00 / 1143.17 | 3 | 3 |
3 | 3 | 1022.84 | 1 | 10.62 | 1845 | 20 | 0.21 / 1143.19 | 2 | 3 |
4 | 12 | 1141.60 | 140 | 7.82 | 1957 | 2143 | 2.36 / 1145.33 | 2 | 3 |
5 | 7 | 1137.04 | 25 | 10.40 | 1983 | 516 | 2.87 / 1145.85 | 3 | 3 |
6 | 13 | 375.00 | 43 | 13.51 | 889 | 516 | 3.39 / 1146.37 | 2 | 3 |
7 | 8 | -0.20 | 180 | 14.18 | 305 | 778 | 4.17 / 1147.15 | 3 | 9 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 29 | 14.06 | 464 | 189 | 0.19 / 1136.52 | 3 | 3 |
2 | 12 | 1137.12 | 5 | 11.08 | 2014 | 112 | 0.30 / 1136.64 | 2 | 3 |
3 | 12 | 2003.20 | 140 | 7.43 | 3257 | 3388 | 3.69 / 1140.02 | 2 | 3 |
4 | 7 | 1983.48 | 25 | 10.28 | 3229 | 830 | 4.52 / 1140.85 | 3 | 3 |
5 | 13 | 1197.04 | 43 | 12.64 | 2048 | 1113 | 5.63 / 1141.97 | 2 | 3 |
6 | 13 | 40.36 | 43 | 14.17 | 368 | 224 | 5.86 / 1142.19 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.27 | 307 | 789 | 6.64 / 1142.98 | 3 | 12 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 29 | 14.07 | 459 | 187 | 0.19 / 1132.10 | 3 | 3 |
2 | 3 | 971.00 | -1 | 14.07 | 459 | 0 | 0.00 / 1132.10 | 3 | 3 |
3 | 12 | 1171.64 | 140 | 6.30 | 1984 | 1750 | 1.94 / 1133.85 | 2 | 3 |
4 | 7 | 1175.80 | 25 | 10.07 | 2045 | 515 | 2.45 / 1134.36 | 3 | 3 |
5 | 13 | 1044.64 | 43 | 11.96 | 1871 | 962 | 3.41 / 1135.33 | 2 | 3 |
6 | 13 | 53.64 | 43 | 14.08 | 385 | 233 | 3.65 / 1135.56 | 2 | 3 |
7 | 8 | 0.12 | 180 | 14.19 | 304 | 776 | 4.42 / 1136.34 | 3 | 11 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 29 | 14.01 | 469 | 191 | 0.19 / 1128.06 | 3 | 3 |
2 | 3 | 1028.00 | 1 | 11.00 | 1855 | 20 | 0.21 / 1128.08 | 2 | 3 |
3 | 12 | 1122.84 | 140 | 7.03 | 1919 | 1889 | 2.10 / 1129.97 | 2 | 3 |
4 | 7 | 1122.52 | 25 | 10.29 | 1962 | 505 | 2.60 / 1130.48 | 3 | 3 |
5 | 13 | 555.24 | 43 | 13.17 | 1155 | 654 | 3.26 / 1131.13 | 2 | 3 |
6 | 8 | -0.04 | 180 | 14.18 | 306 | 781 | 4.04 / 1131.91 | 3 | 5 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 29 | 14.12 | 449 | 184 | 0.18 / 1123.89 | 3 | 3 |
2 | 3 | 964.00 | -1 | 14.12 | 449 | 0 | 0.00 / 1123.89 | 3 | 3 |
3 | 3 | 1028.68 | 1 | 10.93 | 1861 | 20 | 0.20 / 1123.91 | 2 | 3 |
4 | 12 | 1142.28 | 130 | 7.92 | 1966 | 2024 | 2.23 / 1125.93 | 2 | 3 |
5 | 7 | 1138.72 | 25 | 10.46 | 1989 | 520 | 2.75 / 1126.45 | 3 | 3 |
6 | 13 | 525.64 | 43 | 13.26 | 1115 | 636 | 3.38 / 1127.09 | 2 | 3 |
7 | 8 | 0.16 | 180 | 14.17 | 307 | 783 | 4.17 / 1127.87 | 3 | 4 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 30 | 14.06 | 452 | 191 | 0.19 / 1117.46 | 3 | 3 |
2 | 3 | 941.40 | -1 | 14.06 | 452 | 0 | 0.00 / 1117.46 | 3 | 3 |
3 | 12 | 1127.04 | 5 | 11.14 | 2011 | 112 | 0.30 / 1117.57 | 2 | 3 |
4 | 12 | 1997.40 | 130 | 7.76 | 3250 | 3279 | 3.58 / 1120.85 | 2 | 3 |
5 | 7 | 1977.56 | 25 | 10.32 | 3241 | 836 | 4.42 / 1121.68 | 3 | 3 |
6 | 13 | 1044.40 | 43 | 12.81 | 1878 | 1034 | 5.45 / 1122.72 | 2 | 3 |
7 | 13 | 8.84 | 43 | 14.23 | 323 | 198 | 5.65 / 1122.92 | 3 | 3 |
8 | 8 | 0.12 | 180 | 14.28 | 307 | 789 | 6.44 / 1123.70 | 3 | 11 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 30 | 14.00 | 460 | 193 | 0.19 / 1113.12 | 3 | 3 |
2 | 3 | 967.96 | -1 | 14.00 | 460 | 0 | 0.00 / 1113.12 | 3 | 3 |
3 | 3 | 1043.88 | 1 | 11.07 | 1872 | 21 | 0.21 / 1113.14 | 2 | 3 |
4 | 12 | 1143.24 | 130 | 6.51 | 1943 | 1644 | 1.86 / 1114.79 | 2 | 3 |
5 | 7 | 1148.32 | 25 | 10.22 | 2006 | 513 | 2.37 / 1115.30 | 3 | 3 |
6 | 13 | 1019.48 | 43 | 12.07 | 1841 | 955 | 3.33 / 1116.26 | 2 | 3 |
7 | 13 | 44.36 | 43 | 14.08 | 378 | 229 | 3.56 / 1116.49 | 3 | 3 |
8 | 8 | 0.00 | 180 | 14.18 | 306 | 781 | 4.34 / 1117.27 | 3 | 12 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 29 | 14.02 | 463 | 188 | 0.19 / 1109.06 | 3 | 3 |
2 | 12 | 1133.12 | 130 | 7.20 | 1938 | 1814 | 2.00 / 1110.87 | 2 | 3 |
3 | 7 | 1134.56 | 25 | 10.35 | 1984 | 513 | 2.52 / 1111.38 | 3 | 3 |
4 | 13 | 717.24 | 43 | 12.83 | 1396 | 770 | 3.29 / 1112.16 | 2 | 3 |
5 | 8 | 0.12 | 180 | 14.16 | 304 | 775 | 4.06 / 1112.93 | 3 | 13 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 29 | 14.13 | 449 | 184 | 0.18 / 1105.16 | 3 | 3 |
2 | 12 | 1110.04 | 130 | 8.19 | 1921 | 2045 | 2.23 / 1107.21 | 2 | 3 |
3 | 7 | 1108.68 | 24 | 10.65 | 1949 | 498 | 2.73 / 1107.71 | 3 | 3 |
4 | 13 | 215.76 | 43 | 13.76 | 645 | 382 | 3.11 / 1108.09 | 2 | 3 |
5 | 8 | 0.08 | 180 | 14.15 | 306 | 779 | 3.89 / 1108.87 | 3 | 4 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 30 | 14.04 | 460 | 194 | 0.19 / 1098.72 | 3 | 3 |
2 | 3 | 968.60 | -1 | 14.04 | 460 | 0 | 0.00 / 1098.72 | 3 | 3 |
3 | 3 | 1040.00 | 1 | 11.14 | 1876 | 21 | 0.21 / 1098.74 | 2 | 3 |
4 | 12 | 1137.84 | 5 | 11.15 | 2015 | 112 | 0.33 / 1098.86 | 2 | 3 |
5 | 12 | 1996.32 | 130 | 7.72 | 3237 | 3249 | 3.58 / 1102.11 | 2 | 3 |
6 | 7 | 1976.56 | 25 | 10.32 | 3236 | 835 | 4.41 / 1102.94 | 3 | 3 |
7 | 13 | 1053.00 | 43 | 12.82 | 1858 | 1024 | 5.43 / 1103.96 | 2 | 3 |
8 | 13 | 46.12 | 43 | 14.15 | 380 | 231 | 5.67 / 1104.20 | 3 | 3 |
9 | 8 | 0.12 | 180 | 14.26 | 306 | 785 | 6.45 / 1104.98 | 3 | 12 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 30 | 14.03 | 463 | 195 | 0.19 / 1094.68 | 3 | 3 |
2 | 12 | 1107.64 | 130 | 6.95 | 1894 | 1711 | 1.91 / 1096.39 | 2 | 3 |
3 | 7 | 1110.88 | 25 | 10.45 | 1946 | 508 | 2.41 / 1096.90 | 3 | 3 |
4 | 13 | 839.48 | 43 | 12.62 | 1576 | 855 | 3.27 / 1097.75 | 2 | 3 |
5 | 8 | -0.16 | 180 | 14.17 | 304 | 775 | 4.05 / 1098.53 | 3 | 11 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 29 | 14.06 | 447 | 182 | 0.18 / 1090.67 | 3 | 3 |
2 | 12 | 1118.52 | 130 | 7.54 | 1917 | 1879 | 2.06 / 1092.55 | 2 | 3 |
3 | 7 | 1118.40 | 25 | 10.55 | 1959 | 517 | 2.58 / 1093.07 | 3 | 3 |
4 | 13 | 528.88 | 43 | 13.25 | 1115 | 635 | 3.21 / 1093.70 | 2 | 3 |
5 | 8 | 0.36 | 180 | 14.16 | 306 | 780 | 3.99 / 1094.48 | 3 | 4 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 30 | 14.11 | 451 | 191 | 0.19 / 1086.81 | 3 | 3 |
2 | 3 | 969.40 | -1 | 14.11 | 451 | 0 | 0.00 / 1086.81 | 3 | 3 |
3 | 3 | 1036.12 | 1 | 11.25 | 1877 | 21 | 0.21 / 1086.83 | 2 | 3 |
4 | 12 | 1149.44 | 124 | 8.26 | 1975 | 2023 | 2.23 / 1088.85 | 2 | 3 |
5 | 7 | 1145.68 | 25 | 10.69 | 2001 | 535 | 2.77 / 1089.39 | 3 | 3 |
6 | 13 | 273.80 | 33 | 13.73 | 735 | 333 | 3.10 / 1089.72 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.19 | 301 | 769 | 3.87 / 1090.49 | 3 | 4 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 30 | 14.06 | 462 | 195 | 0.19 / 1080.64 | 3 | 3 |
2 | 12 | 1116.16 | 5 | 11.25 | 1990 | 112 | 0.31 / 1080.75 | 2 | 3 |
3 | 12 | 1993.08 | 124 | 8.11 | 3233 | 3251 | 3.56 / 1084.00 | 2 | 3 |
4 | 7 | 1973.24 | 25 | 10.38 | 3237 | 840 | 4.40 / 1084.84 | 3 | 3 |
5 | 13 | 1027.96 | 33 | 13.02 | 1806 | 776 | 5.17 / 1085.62 | 2 | 3 |
6 | 13 | 106.40 | 33 | 14.07 | 474 | 220 | 5.39 / 1085.84 | 2 | 3 |
7 | 8 | 0.04 | 180 | 14.27 | 305 | 783 | 6.18 / 1086.62 | 3 | 8 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 30 | 14.08 | 451 | 191 | 0.19 / 1076.64 | 3 | 3 |
2 | 12 | 1120.48 | 124 | 6.93 | 1915 | 1646 | 1.84 / 1078.28 | 2 | 3 |
3 | 7 | 1124.64 | 25 | 10.60 | 1969 | 522 | 2.36 / 1078.80 | 3 | 3 |
4 | 13 | 861.44 | 33 | 12.79 | 1613 | 681 | 3.04 / 1079.48 | 2 | 3 |
5 | 13 | 51.04 | 33 | 14.09 | 391 | 182 | 3.22 / 1079.67 | 2 | 3 |
6 | 8 | -0.24 | 180 | 14.19 | 304 | 776 | 4.00 / 1080.44 | 3 | 10 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 30 | 14.08 | 444 | 188 | 0.19 / 1072.80 | 3 | 3 |
2 | 12 | 1115.40 | 105 | 7.38 | 1914 | 1483 | 1.67 / 1074.28 | 2 | 3 |
3 | 7 | 1117.76 | 25 | 10.66 | 1966 | 524 | 2.19 / 1074.81 | 3 | 3 |
4 | 13 | 866.80 | 33 | 12.75 | 1622 | 682 | 2.88 / 1075.49 | 2 | 3 |
5 | 13 | 59.96 | 33 | 14.06 | 403 | 187 | 3.06 / 1075.68 | 3 | 3 |
6 | 8 | 0.12 | 180 | 14.19 | 301 | 769 | 3.83 / 1076.45 | 3 | 11 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 30 | 14.14 | 458 | 194 | 0.19 / 1068.94 | 3 | 3 |
2 | 12 | 1121.48 | 105 | 8.43 | 1947 | 1723 | 1.92 / 1070.66 | 2 | 3 |
3 | 7 | 1121.88 | 24 | 10.89 | 1973 | 516 | 2.43 / 1071.18 | 3 | 3 |
4 | 13 | 568.44 | 33 | 13.32 | 1185 | 521 | 2.95 / 1071.70 | 2 | 3 |
5 | 13 | 6.00 | 33 | 14.19 | 311 | 146 | 3.10 / 1071.84 | 3 | 5 |
6 | 8 | -0.12 | 180 | 14.20 | 301 | 769 | 3.87 / 1072.61 | 3 | 11 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 29 | 14.09 | 453 | 185 | 0.19 / 1063.12 | 3 | 3 |
2 | 12 | 1126.20 | 5 | 11.48 | 1990 | 114 | 0.30 / 1063.23 | 2 | 3 |
3 | 12 | 1997.16 | 105 | 8.35 | 3243 | 2843 | 3.14 / 1066.08 | 2 | 3 |
4 | 7 | 1981.00 | 24 | 10.45 | 3251 | 815 | 3.96 / 1066.89 | 3 | 3 |
5 | 13 | 1059.92 | 33 | 12.95 | 1896 | 810 | 4.77 / 1067.70 | 2 | 3 |
6 | 13 | 152.04 | 33 | 13.99 | 553 | 255 | 5.02 / 1067.96 | 2 | 3 |
7 | 8 | 0.36 | 180 | 14.25 | 306 | 785 | 5.81 / 1068.74 | 3 | 9 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 30 | 14.09 | 452 | 191 | 0.19 / 1059.15 | 3 | 3 |
2 | 12 | 1127.84 | 105 | 7.01 | 1923 | 1415 | 1.61 / 1060.57 | 2 | 3 |
3 | 7 | 1133.68 | 25 | 10.65 | 1990 | 530 | 2.14 / 1061.10 | 3 | 3 |
4 | 13 | 1016.04 | 33 | 12.47 | 1846 | 760 | 2.90 / 1061.86 | 2 | 3 |
5 | 13 | 238.76 | 33 | 13.77 | 682 | 310 | 3.21 / 1062.17 | 2 | 3 |
6 | 8 | 0.12 | 180 | 14.19 | 300 | 766 | 3.97 / 1062.93 | 3 | 6 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 29 | 14.09 | 447 | 183 | 0.18 / 1055.19 | 3 | 3 |
2 | 12 | 1120.20 | 105 | 7.51 | 1914 | 1509 | 1.69 / 1056.70 | 2 | 3 |
3 | 7 | 1124.44 | 25 | 10.76 | 1978 | 532 | 2.22 / 1057.23 | 3 | 3 |
4 | 13 | 994.32 | 33 | 12.59 | 1809 | 752 | 2.98 / 1057.99 | 2 | 3 |
5 | 13 | 89.24 | 33 | 14.02 | 449 | 208 | 3.18 / 1058.19 | 2 | 3 |
6 | 8 | -0.04 | 180 | 14.20 | 301 | 769 | 3.95 / 1058.96 | 3 | 5 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 29 | 14.18 | 436 | 179 | 0.18 / 1051.30 | 3 | 3 |
2 | 12 | 1130.12 | 100 | 8.60 | 1945 | 1673 | 1.85 / 1052.97 | 2 | 3 |
3 | 7 | 1129.20 | 24 | 10.95 | 1984 | 521 | 2.37 / 1053.49 | 3 | 3 |
4 | 13 | 704.80 | 33 | 13.17 | 1376 | 598 | 2.97 / 1054.09 | 2 | 3 |
5 | 13 | 18.36 | 33 | 14.18 | 331 | 155 | 3.13 / 1054.25 | 3 | 3 |
6 | 8 | -0.12 | 180 | 14.20 | 299 | 764 | 3.89 / 1055.01 | 3 | 11 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 29 | 14.11 | 437 | 179 | 0.18 / 1045.56 | 3 | 3 |
2 | 12 | 1124.24 | 6 | 11.51 | 1993 | 138 | 0.32 / 1045.69 | 2 | 3 |
3 | 12 | 1966.20 | 100 | 8.71 | 3196 | 2784 | 3.10 / 1048.48 | 2 | 3 |
4 | 7 | 1951.32 | 25 | 10.49 | 3189 | 836 | 3.94 / 1049.31 | 3 | 3 |
5 | 13 | 1029.84 | 33 | 12.98 | 1860 | 797 | 4.73 / 1050.11 | 2 | 3 |
6 | 13 | 116.88 | 33 | 14.05 | 491 | 228 | 4.96 / 1050.34 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.26 | 304 | 780 | 5.74 / 1051.12 | 3 | 8 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 30 | 14.14 | 440 | 187 | 0.19 / 1041.73 | 3 | 3 |
2 | 12 | 1109.64 | 100 | 7.51 | 1897 | 1425 | 1.61 / 1043.15 | 2 | 3 |
3 | 7 | 1112.76 | 24 | 10.89 | 1960 | 512 | 2.12 / 1043.66 | 3 | 3 |
4 | 13 | 979.00 | 33 | 12.60 | 1788 | 743 | 2.87 / 1044.41 | 2 | 3 |
5 | 13 | 99.44 | 33 | 14.00 | 462 | 213 | 3.08 / 1044.62 | 2 | 3 |
6 | 8 | -0.16 | 180 | 14.19 | 297 | 759 | 3.84 / 1045.38 | 3 | 11 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 29 | 14.13 | 438 | 179 | 0.18 / 1037.90 | 3 | 3 |
2 | 12 | 1127.76 | 100 | 7.64 | 1927 | 1472 | 1.65 / 1039.37 | 2 | 3 |
3 | 7 | 1130.44 | 25 | 10.90 | 1981 | 540 | 2.19 / 1039.91 | 3 | 3 |
4 | 13 | 868.84 | 33 | 12.94 | 1625 | 694 | 2.89 / 1040.61 | 2 | 3 |
5 | 13 | 35.60 | 33 | 14.14 | 360 | 168 | 3.05 / 1040.78 | 2 | 3 |
6 | 8 | -0.12 | 180 | 14.22 | 298 | 763 | 3.82 / 1041.54 | 3 | 13 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 29 | 14.17 | 438 | 180 | 0.18 / 1034.07 | 3 | 3 |
2 | 12 | 1123.72 | 90 | 8.84 | 1943 | 1546 | 1.73 / 1035.62 | 2 | 3 |
3 | 7 | 1125.44 | 25 | 11.08 | 1979 | 548 | 2.27 / 1036.17 | 3 | 3 |
4 | 13 | 713.68 | 33 | 13.21 | 1399 | 610 | 2.88 / 1036.78 | 2 | 3 |
5 | 13 | 40.56 | 33 | 14.13 | 375 | 175 | 3.06 / 1036.95 | 3 | 3 |
6 | 8 | 0.04 | 180 | 14.21 | 302 | 772 | 3.83 / 1037.72 | 3 | 20 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 29 | 14.15 | 431 | 177 | 0.18 / 1028.53 | 3 | 3 |
2 | 12 | 1117.72 | 7 | 11.83 | 1988 | 165 | 0.34 / 1028.69 | 2 | 3 |
3 | 12 | 1929.64 | 90 | 9.23 | 3145 | 2613 | 2.95 / 1031.31 | 2 | 3 |
4 | 7 | 1915.12 | 25 | 10.62 | 3133 | 832 | 3.79 / 1032.14 | 3 | 3 |
5 | 13 | 999.56 | 33 | 13.07 | 1763 | 760 | 4.55 / 1032.90 | 2 | 3 |
6 | 13 | 89.04 | 33 | 14.09 | 452 | 210 | 4.76 / 1033.11 | 2 | 3 |
7 | 8 | 0.08 | 180 | 14.25 | 305 | 782 | 5.54 / 1033.89 | 3 | 7 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 29 | 14.11 | 450 | 184 | 0.18 / 1024.63 | 3 | 3 |
2 | 12 | 1128.16 | 90 | 7.28 | 1924 | 1261 | 1.44 / 1025.89 | 2 | 3 |
3 | 7 | 1135.20 | 25 | 10.85 | 1995 | 541 | 1.99 / 1026.43 | 3 | 3 |
4 | 13 | 1023.28 | 33 | 12.64 | 1837 | 766 | 2.75 / 1027.20 | 2 | 3 |
5 | 13 | 143.68 | 33 | 13.94 | 528 | 243 | 3.00 / 1027.44 | 3 | 3 |
6 | 13 | 8.56 | 33 | 14.18 | 313 | 146 | 3.14 / 1027.59 | 3 | 3 |
7 | 8 | -0.08 | 180 | 14.20 | 299 | 764 | 3.91 / 1028.35 | 3 | 12 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 29 | 14.09 | 444 | 181 | 0.18 / 1020.76 | 3 | 3 |
2 | 12 | 1130.68 | 90 | 7.83 | 1935 | 1364 | 1.55 / 1022.12 | 2 | 3 |
3 | 7 | 1136.20 | 25 | 10.98 | 2001 | 549 | 2.09 / 1022.67 | 3 | 3 |
4 | 13 | 1013.52 | 33 | 12.69 | 1842 | 771 | 2.87 / 1023.44 | 2 | 3 |
5 | 13 | 118.08 | 33 | 13.98 | 498 | 230 | 3.10 / 1023.67 | 2 | 3 |
6 | 8 | -0.08 | 180 | 14.19 | 304 | 776 | 3.87 / 1024.45 | 3 | 8 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 29 | 14.14 | 455 | 187 | 0.19 / 1016.93 | 3 | 3 |
2 | 12 | 1101.68 | 90 | 9.08 | 1920 | 1569 | 1.76 / 1018.50 | 2 | 3 |
3 | 7 | 1102.44 | 25 | 11.18 | 1949 | 545 | 2.30 / 1019.05 | 3 | 3 |
4 | 13 | 689.36 | 33 | 13.27 | 1353 | 592 | 2.89 / 1019.64 | 2 | 3 |
5 | 13 | 17.32 | 33 | 14.18 | 337 | 158 | 3.05 / 1019.80 | 3 | 3 |
6 | 8 | -0.04 | 180 | 14.20 | 305 | 780 | 3.83 / 1020.58 | 3 | 10 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 29 | 14.08 | 442 | 180 | 0.18 / 1011.38 | 3 | 3 |
2 | 12 | 1107.80 | 7 | 11.90 | 1986 | 165 | 0.35 / 1011.55 | 2 | 3 |
3 | 12 | 1934.88 | 90 | 9.21 | 3154 | 2614 | 2.96 / 1014.16 | 2 | 3 |
4 | 7 | 1919.52 | 25 | 10.63 | 3158 | 839 | 3.80 / 1015.00 | 3 | 3 |
5 | 13 | 978.24 | 33 | 13.07 | 1785 | 770 | 4.57 / 1015.77 | 2 | 3 |
6 | 13 | 41.44 | 33 | 14.18 | 378 | 177 | 4.75 / 1015.95 | 3 | 3 |
7 | 8 | 0.08 | 180 | 14.25 | 311 | 798 | 5.54 / 1016.75 | 3 | 9 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 29 | 14.12 | 445 | 182 | 0.18 / 1007.59 | 3 | 3 |
2 | 12 | 1112.08 | 90 | 7.76 | 1903 | 1329 | 1.51 / 1008.92 | 2 | 3 |
3 | 7 | 1116.72 | 25 | 10.99 | 1971 | 542 | 2.05 / 1009.46 | 3 | 3 |
4 | 13 | 985.12 | 33 | 12.70 | 1800 | 754 | 2.81 / 1010.22 | 2 | 3 |
5 | 13 | 93.32 | 33 | 14.02 | 457 | 211 | 3.02 / 1010.43 | 2 | 3 |
6 | 8 | -0.12 | 180 | 14.19 | 302 | 771 | 3.79 / 1011.20 | 3 | 7 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 29 | 14.11 | 449 | 184 | 0.18 / 1003.70 | 3 | 3 |
2 | 12 | 1126.24 | 90 | 8.06 | 1926 | 1397 | 1.58 / 1005.10 | 2 | 3 |
3 | 7 | 1130.92 | 25 | 11.10 | 1991 | 553 | 2.13 / 1005.65 | 3 | 3 |
4 | 13 | 998.48 | 33 | 12.80 | 1817 | 768 | 2.90 / 1006.42 | 2 | 3 |
5 | 13 | 91.40 | 33 | 14.03 | 456 | 211 | 3.11 / 1006.63 | 2 | 3 |
6 | 8 | -0.08 | 180 | 14.20 | 305 | 780 | 3.89 / 1007.41 | 3 | 8 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 29 | 14.14 | 450 | 185 | 0.18 / 999.90 | 3 | 3 |
2 | 12 | 1121.04 | 90 | 9.16 | 1945 | 1603 | 1.79 / 1001.50 | 2 | 3 |
3 | 7 | 1120.24 | 25 | 11.25 | 1974 | 555 | 2.34 / 1002.06 | 3 | 3 |
4 | 13 | 568.68 | 33 | 13.44 | 1182 | 524 | 2.87 / 1002.58 | 2 | 3 |
5 | 13 | 19.48 | 33 | 14.20 | 336 | 157 | 3.02 / 1002.74 | 2 | 3 |
6 | 8 | -0.12 | 180 | 14.22 | 304 | 778 | 3.80 / 1003.52 | 3 | 11 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 29 | 14.11 | 446 | 182 | 0.18 / 994.33 | 3 | 3 |
2 | 12 | 1118.60 | 7 | 11.95 | 1984 | 166 | 0.35 / 994.49 | 2 | 3 |
3 | 12 | 1931.00 | 90 | 9.61 | 3155 | 2729 | 3.08 / 997.22 | 2 | 3 |
4 | 7 | 1916.12 | 25 | 10.73 | 3146 | 844 | 3.92 / 998.07 | 3 | 3 |
5 | 13 | 835.36 | 33 | 13.27 | 1567 | 686 | 4.61 / 998.75 | 2 | 3 |
6 | 13 | 42.16 | 33 | 14.21 | 373 | 175 | 4.78 / 998.93 | 3 | 3 |
7 | 8 | 0.04 | 180 | 14.28 | 307 | 789 | 5.57 / 999.72 | 3 | 7 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 29 | 14.10 | 445 | 182 | 0.18 / 990.53 | 3 | 3 |
2 | 12 | 1134.12 | 90 | 8.02 | 1934 | 1396 | 1.58 / 991.93 | 2 | 3 |
3 | 7 | 1138.24 | 25 | 11.10 | 2004 | 556 | 2.13 / 992.49 | 3 | 3 |
4 | 13 | 881.68 | 33 | 13.02 | 1637 | 703 | 2.84 / 993.19 | 2 | 3 |
5 | 13 | 59.40 | 33 | 14.10 | 399 | 186 | 3.02 / 993.37 | 2 | 3 |
6 | 8 | 0.00 | 180 | 14.22 | 301 | 770 | 3.79 / 994.15 | 3 | 7 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 29 | 14.11 | 459 | 188 | 0.19 / 986.77 | 3 | 3 |
2 | 12 | 1129.68 | 90 | 8.43 | 1933 | 1467 | 1.65 / 988.24 | 2 | 3 |
3 | 7 | 1131.08 | 25 | 11.21 | 1987 | 557 | 2.21 / 988.79 | 3 | 3 |
4 | 13 | 735.16 | 33 | 13.27 | 1411 | 618 | 2.83 / 989.41 | 2 | 3 |
5 | 13 | 27.04 | 33 | 14.20 | 345 | 162 | 2.99 / 989.57 | 2 | 3 |
6 | 8 | 0.08 | 180 | 14.23 | 304 | 779 | 3.77 / 990.35 | 3 | 7 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 29 | 14.14 | 458 | 188 | 0.19 / 983.09 | 3 | 3 |
2 | 12 | 1109.32 | 90 | 9.46 | 1927 | 1641 | 1.83 / 984.74 | 2 | 3 |
3 | 7 | 1108.60 | 25 | 11.40 | 1953 | 557 | 2.39 / 985.29 | 3 | 3 |
4 | 13 | 546.56 | 33 | 13.53 | 1149 | 513 | 2.90 / 985.81 | 2 | 3 |
5 | 8 | 0.04 | 180 | 14.25 | 303 | 777 | 3.68 / 986.58 | 3 | 13 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 29 | 14.06 | 465 | 190 | 0.19 / 977.68 | 3 | 3 |
2 | 12 | 1129.32 | 7 | 12.14 | 2019 | 172 | 0.36 / 977.85 | 2 | 3 |
3 | 12 | 1926.88 | 90 | 10.03 | 3144 | 2838 | 3.20 / 980.69 | 2 | 3 |
4 | 7 | 1910.00 | 25 | 10.80 | 3142 | 848 | 4.05 / 981.54 | 3 | 3 |
5 | 13 | 656.52 | 33 | 13.47 | 1309 | 582 | 4.63 / 982.12 | 2 | 3 |
6 | 8 | 0.04 | 180 | 14.28 | 307 | 789 | 5.42 / 982.91 | 3 | 10 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 29 | 14.09 | 461 | 188 | 0.19 / 973.70 | 3 | 3 |
2 | 12 | 1125.64 | 90 | 8.75 | 1937 | 1525 | 1.71 / 975.22 | 2 | 3 |
3 | 7 | 1127.60 | 25 | 11.32 | 1985 | 562 | 2.28 / 975.78 | 3 | 3 |
4 | 13 | 858.24 | 33 | 13.15 | 1611 | 699 | 2.97 / 976.48 | 2 | 3 |
5 | 13 | 118.16 | 33 | 14.04 | 493 | 228 | 3.20 / 976.71 | 3 | 3 |
6 | 8 | -0.04 | 180 | 14.25 | 303 | 777 | 3.98 / 977.49 | 3 | 8 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 29 | 14.09 | 467 | 191 | 0.19 / 969.99 | 3 | 3 |
2 | 12 | 1132.80 | 90 | 9.35 | 1967 | 1655 | 1.85 / 971.65 | 2 | 3 |
3 | 7 | 1132.40 | 24 | 11.40 | 1993 | 545 | 2.39 / 972.19 | 3 | 3 |
4 | 13 | 570.36 | 33 | 13.49 | 1186 | 528 | 2.92 / 972.72 | 2 | 3 |
5 | 8 | 0.04 | 180 | 14.23 | 308 | 789 | 3.71 / 973.51 | 3 | 10 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 29 | 14.13 | 455 | 186 | 0.19 / 966.48 | 3 | 3 |
2 | 12 | 1119.08 | 25 | 9.58 | 1960 | 469 | 0.66 / 966.95 | 2 | 3 |
3 | 7 | 1126.12 | 25 | 12.04 | 1992 | 600 | 1.26 / 967.55 | 3 | 3 |
4 | 13 | 1072.28 | 33 | 12.73 | 1925 | 809 | 2.06 / 968.36 | 2 | 3 |
5 | 13 | 810.96 | 33 | 13.21 | 1531 | 667 | 2.73 / 969.02 | 2 | 3 |
6 | 8 | 0.40 | 180 | 14.23 | 303 | 776 | 3.51 / 969.80 | 3 | 12 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 30 | 14.11 | 448 | 190 | 0.19 / 961.68 | 3 | 3 |
2 | 3 | 936.28 | -1 | 14.11 | 448 | 0 | 0.00 / 961.68 | 3 | 3 |
3 | 12 | 1115.84 | 10 | 12.22 | 1981 | 242 | 0.43 / 961.92 | 2 | 3 |
4 | 12 | 1833.68 | 25 | 11.13 | 3036 | 845 | 1.28 / 962.76 | 2 | 3 |
5 | 7 | 1827.84 | 25 | 11.39 | 3029 | 863 | 2.14 / 963.62 | 3 | 3 |
6 | 13 | 1562.24 | 33 | 12.50 | 2607 | 1075 | 3.21 / 964.70 | 2 | 3 |
7 | 13 | 815.16 | 33 | 13.34 | 1464 | 644 | 3.86 / 965.34 | 2 | 3 |
8 | 13 | 16.64 | 33 | 14.27 | 333 | 157 | 4.02 / 965.50 | 3 | 3 |
9 | 8 | 0.20 | 180 | 14.27 | 308 | 791 | 4.81 / 966.29 | 3 | 9 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 29 | 14.14 | 454 | 186 | 0.19 / 957.95 | 3 | 3 |
2 | 12 | 1121.28 | 25 | 9.20 | 1954 | 449 | 0.64 / 958.40 | 2 | 3 |
3 | 7 | 1128.12 | 25 | 11.89 | 2001 | 595 | 1.23 / 958.99 | 3 | 3 |
4 | 13 | 1088.64 | 33 | 12.64 | 1942 | 810 | 2.04 / 959.80 | 2 | 3 |
5 | 13 | 957.16 | 33 | 12.96 | 1735 | 742 | 2.78 / 960.54 | 2 | 3 |
6 | 13 | 32.60 | 33 | 14.20 | 356 | 167 | 2.95 / 960.71 | 3 | 3 |
7 | 8 | -0.20 | 180 | 14.24 | 303 | 777 | 3.73 / 961.49 | 3 | 7 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 23 | 14.13 | 461 | 150 | 0.15 / 953.07 | 3 | 3 |
2 | 10 | 1007.72 | 4 | 13.04 | 1828 | 95 | 0.25 / 953.17 | 2 | 3 |
3 | 3 | 1063.00 | 2 | 12.43 | 1936 | 48 | 0.29 / 953.21 | 2 | 3 |
4 | 3 | 1025.40 | 1 | 11.76 | 1869 | 22 | 0.32 / 953.24 | 2 | 3 |
5 | 12 | 1141.56 | 10 | 12.43 | 2025 | 252 | 0.57 / 953.49 | 2 | 3 |
6 | 12 | 1839.48 | 25 | 11.28 | 3044 | 858 | 1.43 / 954.35 | 2 | 3 |
7 | 7 | 1834.20 | 25 | 11.49 | 3040 | 873 | 2.30 / 955.22 | 3 | 3 |
8 | 13 | 1564.84 | 33 | 12.57 | 2617 | 1086 | 3.38 / 956.31 | 2 | 3 |
9 | 13 | 822.08 | 33 | 13.35 | 1492 | 657 | 4.04 / 956.96 | 2 | 3 |
10 | 8 | 0.20 | 180 | 14.29 | 310 | 797 | 4.84 / 957.76 | 3 | 10 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 28 | 14.13 | 461 | 182 | 0.18 / 946.74 | 3 | 3 |
2 | 12 | 1129.80 | 11 | 9.23 | 1963 | 199 | 0.38 / 946.94 | 2 | 3 |
3 | 12 | 1998.08 | 90 | 6.16 | 3283 | 1820 | 2.20 / 948.76 | 2 | 3 |
4 | 12 | 1995.56 | 25 | 9.41 | 3252 | 765 | 2.97 / 949.53 | 2 | 3 |
5 | 7 | 1986.76 | 25 | 10.40 | 3249 | 845 | 3.81 / 950.37 | 3 | 3 |
6 | 13 | 1434.00 | 33 | 12.66 | 2406 | 1005 | 4.82 / 951.38 | 2 | 3 |
7 | 13 | 709.48 | 33 | 13.44 | 1332 | 591 | 5.41 / 951.97 | 2 | 3 |
8 | 13 | 22.60 | 33 | 14.26 | 345 | 162 | 5.57 / 952.13 | 2 | 3 |
9 | 8 | 0.08 | 180 | 14.31 | 307 | 791 | 6.36 / 952.92 | 3 | 6 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 28 | 14.16 | 462 | 183 | 0.18 / 940.62 | 3 | 3 |
2 | 12 | 1132.36 | 11 | 9.35 | 1974 | 203 | 0.39 / 940.83 | 2 | 3 |
3 | 12 | 1984.00 | 90 | 6.49 | 3221 | 1881 | 2.27 / 942.71 | 2 | 3 |
4 | 12 | 1980.76 | 25 | 9.40 | 3217 | 756 | 3.02 / 943.46 | 2 | 3 |
5 | 7 | 1971.64 | 25 | 10.44 | 3225 | 842 | 3.87 / 944.31 | 3 | 3 |
6 | 13 | 1396.72 | 33 | 12.66 | 2372 | 991 | 4.86 / 945.30 | 2 | 3 |
7 | 13 | 501.44 | 33 | 13.63 | 1037 | 466 | 5.32 / 945.76 | 2 | 3 |
8 | 8 | -0.04 | 180 | 14.28 | 310 | 797 | 6.12 / 946.56 | 3 | 10 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 28 | 14.15 | 447 | 177 | 0.18 / 934.41 | 3 | 3 |
2 | 12 | 1123.08 | 9 | 8.81 | 1971 | 156 | 0.33 / 934.57 | 2 | 3 |
3 | 12 | 2000.28 | 97 | 6.43 | 3259 | 2033 | 2.37 / 936.60 | 2 | 3 |
4 | 7 | 1992.32 | 25 | 10.33 | 3262 | 842 | 3.21 / 937.44 | 3 | 3 |
5 | 13 | 1718.84 | 33 | 12.29 | 2867 | 1163 | 4.37 / 938.61 | 2 | 3 |
6 | 13 | 1129.72 | 33 | 13.02 | 1958 | 841 | 5.21 / 939.45 | 2 | 3 |
7 | 13 | 90.60 | 33 | 14.14 | 451 | 210 | 5.42 / 939.66 | 2 | 3 |
8 | 8 | 0.12 | 180 | 14.30 | 304 | 782 | 6.21 / 940.44 | 3 | 7 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 28 | 14.16 | 456 | 181 | 0.18 / 928.09 | 3 | 3 |
2 | 3 | 972.92 | -1 | 14.16 | 456 | 0 | 0.00 / 928.09 | 3 | 3 |
3 | 3 | 1033.16 | 1 | 12.19 | 1874 | 23 | 0.20 / 928.11 | 2 | 3 |
4 | 12 | 1145.24 | 9 | 8.77 | 1998 | 158 | 0.36 / 928.27 | 2 | 3 |
5 | 12 | 2002.12 | 97 | 6.46 | 3275 | 2052 | 2.41 / 930.32 | 2 | 3 |
6 | 7 | 1996.36 | 25 | 10.34 | 3260 | 843 | 3.26 / 931.16 | 3 | 3 |
7 | 13 | 1866.16 | 33 | 12.07 | 3097 | 1234 | 4.49 / 932.40 | 2 | 3 |
8 | 13 | 1111.04 | 33 | 13.02 | 1948 | 837 | 5.33 / 933.23 | 2 | 3 |
9 | 13 | 92.72 | 33 | 14.14 | 454 | 212 | 5.54 / 933.45 | 3 | 3 |
10 | 8 | -0.12 | 180 | 14.30 | 307 | 790 | 6.33 / 934.24 | 3 | 7 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 28 | 14.16 | 455 | 180 | 0.18 / 922.03 | 3 | 3 |
2 | 12 | 1116.00 | 9 | 9.26 | 1958 | 163 | 0.34 / 922.19 | 2 | 3 |
3 | 12 | 2001.08 | 91 | 6.48 | 3265 | 1925 | 2.27 / 924.12 | 2 | 3 |
4 | 7 | 1994.16 | 25 | 10.41 | 3259 | 848 | 3.12 / 924.97 | 3 | 3 |
5 | 13 | 1717.80 | 33 | 12.31 | 2872 | 1167 | 4.28 / 926.13 | 2 | 3 |
6 | 13 | 996.24 | 33 | 13.15 | 1760 | 764 | 5.05 / 926.90 | 2 | 3 |
7 | 13 | 102.60 | 33 | 14.12 | 474 | 221 | 5.27 / 927.12 | 3 | 3 |
8 | 8 | -0.08 | 180 | 14.30 | 306 | 788 | 6.06 / 927.91 | 3 | 4 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 27 | 14.17 | 455 | 174 | 0.17 / 915.89 | 3 | 3 |
2 | 3 | 1024.32 | 1 | 12.46 | 1885 | 23 | 0.20 / 915.91 | 2 | 3 |
3 | 12 | 1123.44 | 9 | 8.99 | 1946 | 157 | 0.36 / 916.07 | 2 | 3 |
4 | 12 | 2001.48 | 91 | 6.65 | 3257 | 1971 | 2.33 / 918.04 | 2 | 3 |
5 | 7 | 1995.20 | 25 | 10.42 | 3277 | 854 | 3.18 / 918.89 | 3 | 3 |
6 | 13 | 1860.64 | 33 | 12.10 | 3094 | 1235 | 4.42 / 920.13 | 2 | 3 |
7 | 13 | 975.64 | 33 | 13.16 | 1757 | 763 | 5.18 / 920.89 | 2 | 3 |
8 | 13 | 21.56 | 33 | 14.27 | 344 | 162 | 5.34 / 921.05 | 2 | 3 |
9 | 8 | 0.12 | 180 | 14.31 | 310 | 798 | 6.14 / 921.85 | 3 | 6 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 29 | 14.18 | 456 | 188 | 0.19 / 909.86 | 3 | 3 |
2 | 3 | 940.88 | -1 | 14.18 | 456 | 0 | 0.00 / 909.86 | 3 | 3 |
3 | 12 | 1127.04 | 9 | 9.03 | 1976 | 161 | 0.35 / 910.03 | 2 | 3 |
4 | 12 | 2000.96 | 85 | 6.66 | 3263 | 1847 | 2.20 / 911.87 | 2 | 3 |
5 | 7 | 1994.40 | 25 | 10.41 | 3277 | 853 | 3.05 / 912.73 | 3 | 3 |
6 | 13 | 1742.12 | 33 | 12.27 | 2918 | 1182 | 4.23 / 913.91 | 2 | 3 |
7 | 13 | 1009.08 | 33 | 13.15 | 1787 | 775 | 5.01 / 914.68 | 2 | 3 |
8 | 13 | 120.16 | 33 | 14.10 | 503 | 234 | 5.24 / 914.92 | 2 | 3 |
9 | 8 | 0.04 | 180 | 14.30 | 309 | 795 | 6.03 / 915.71 | 3 | 12 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 29 | 14.18 | 467 | 192 | 0.19 / 903.80 | 3 | 3 |
2 | 12 | 1130.00 | 9 | 8.95 | 1987 | 160 | 0.35 / 903.96 | 2 | 3 |
3 | 12 | 2002.16 | 85 | 6.60 | 3266 | 1832 | 2.18 / 905.79 | 2 | 3 |
4 | 7 | 1996.80 | 25 | 10.42 | 3277 | 854 | 3.04 / 906.65 | 3 | 3 |
5 | 13 | 1863.00 | 33 | 12.09 | 3102 | 1238 | 4.28 / 907.88 | 2 | 3 |
6 | 13 | 984.64 | 33 | 13.17 | 1767 | 768 | 5.04 / 908.65 | 2 | 3 |
7 | 13 | 110.76 | 33 | 14.11 | 492 | 229 | 5.27 / 908.88 | 2 | 3 |
8 | 8 | -0.16 | 180 | 14.30 | 309 | 795 | 6.07 / 909.68 | 3 | 3 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 29 | 14.19 | 453 | 186 | 0.19 / 897.69 | 3 | 3 |
2 | 12 | 1104.20 | 9 | 9.38 | 1923 | 162 | 0.35 / 897.85 | 2 | 3 |
3 | 12 | 2003.56 | 85 | 6.64 | 3265 | 1843 | 2.19 / 899.70 | 2 | 3 |
4 | 7 | 1997.76 | 24 | 10.50 | 3267 | 823 | 3.01 / 900.52 | 3 | 3 |
5 | 13 | 1866.80 | 33 | 12.13 | 3085 | 1235 | 4.25 / 901.75 | 2 | 3 |
6 | 13 | 1100.68 | 33 | 13.06 | 1954 | 842 | 5.09 / 902.60 | 2 | 3 |
7 | 13 | 86.32 | 33 | 14.15 | 450 | 210 | 5.30 / 902.81 | 2 | 3 |
8 | 8 | 0.20 | 180 | 14.30 | 312 | 803 | 6.11 / 903.61 | 3 | 5 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 29 | 14.19 | 457 | 188 | 0.19 / 891.68 | 3 | 3 |
2 | 12 | 1115.48 | 9 | 9.20 | 1943 | 161 | 0.35 / 891.84 | 2 | 3 |
3 | 12 | 2001.44 | 79 | 6.71 | 3266 | 1731 | 2.08 / 893.57 | 2 | 3 |
4 | 7 | 1996.12 | 25 | 10.41 | 3277 | 853 | 2.93 / 894.42 | 3 | 3 |
5 | 13 | 1866.20 | 33 | 12.12 | 3098 | 1239 | 4.17 / 895.66 | 2 | 3 |
6 | 13 | 1109.60 | 33 | 13.04 | 1927 | 829 | 5.00 / 896.49 | 2 | 3 |
7 | 13 | 103.48 | 33 | 14.13 | 477 | 222 | 5.22 / 896.71 | 2 | 3 |
8 | 8 | 0.00 | 180 | 14.30 | 307 | 790 | 6.01 / 897.50 | 3 | 6 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 28 | 14.21 | 460 | 183 | 0.18 / 885.73 | 3 | 3 |
2 | 12 | 1125.92 | 9 | 9.43 | 1970 | 167 | 0.35 / 885.90 | 2 | 3 |
3 | 12 | 2001.88 | 79 | 6.94 | 3240 | 1776 | 2.13 / 887.68 | 2 | 3 |
4 | 7 | 1996.32 | 25 | 10.43 | 3278 | 855 | 2.98 / 888.53 | 3 | 3 |
5 | 13 | 1732.32 | 33 | 12.33 | 2878 | 1171 | 4.15 / 889.70 | 2 | 3 |
6 | 13 | 995.36 | 33 | 13.15 | 1787 | 775 | 4.93 / 890.48 | 2 | 3 |
7 | 13 | 97.16 | 33 | 14.14 | 468 | 218 | 5.15 / 890.70 | 2 | 3 |
8 | 8 | -0.12 | 180 | 14.30 | 308 | 793 | 5.94 / 891.49 | 3 | 6 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 28 | 14.21 | 451 | 179 | 0.18 / 880.11 | 3 | 3 |
2 | 12 | 1106.48 | 9 | 9.43 | 1940 | 165 | 0.34 / 880.27 | 2 | 3 |
3 | 12 | 2001.68 | 79 | 7.19 | 3240 | 1840 | 2.18 / 882.11 | 2 | 3 |
4 | 7 | 1996.32 | 25 | 10.50 | 3274 | 859 | 3.04 / 882.97 | 3 | 3 |
5 | 13 | 1593.48 | 33 | 12.51 | 2665 | 1100 | 4.14 / 884.07 | 2 | 3 |
6 | 13 | 854.40 | 33 | 13.30 | 1555 | 682 | 4.83 / 884.76 | 2 | 3 |
7 | 8 | 0.36 | 180 | 14.30 | 309 | 795 | 5.62 / 885.55 | 3 | 8 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 28 | 14.19 | 449 | 178 | 0.18 / 874.47 | 3 | 3 |
2 | 12 | 1113.92 | 9 | 9.66 | 1953 | 170 | 0.35 / 874.64 | 2 | 3 |
3 | 12 | 2000.44 | 73 | 7.02 | 3252 | 1667 | 2.01 / 876.30 | 2 | 3 |
4 | 7 | 1995.72 | 25 | 10.49 | 3266 | 857 | 2.87 / 877.16 | 3 | 3 |
5 | 13 | 1614.12 | 32 | 12.53 | 2682 | 1075 | 3.95 / 878.23 | 2 | 3 |
6 | 13 | 925.80 | 32 | 13.28 | 1643 | 698 | 4.64 / 878.93 | 2 | 3 |
7 | 13 | 94.88 | 32 | 14.15 | 462 | 209 | 4.85 / 879.14 | 3 | 3 |
8 | 8 | -0.12 | 180 | 14.30 | 306 | 788 | 5.64 / 879.93 | 3 | 5 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 28 | 14.22 | 456 | 182 | 0.18 / 868.67 | 3 | 3 |
2 | 12 | 1128.24 | 9 | 9.07 | 1981 | 162 | 0.34 / 868.84 | 2 | 3 |
3 | 12 | 2000.72 | 73 | 7.15 | 3243 | 1693 | 2.04 / 870.53 | 2 | 3 |
4 | 7 | 1994.84 | 25 | 10.49 | 3268 | 857 | 2.89 / 871.39 | 3 | 3 |
5 | 13 | 1723.64 | 32 | 12.42 | 2892 | 1149 | 4.04 / 872.53 | 2 | 3 |
6 | 13 | 978.80 | 32 | 13.22 | 1734 | 734 | 4.78 / 873.27 | 2 | 3 |
7 | 13 | 110.52 | 32 | 14.12 | 491 | 222 | 5.00 / 873.49 | 2 | 3 |
8 | 8 | 0.00 | 180 | 14.29 | 310 | 797 | 5.80 / 874.29 | 3 | 5 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 29 | 14.20 | 446 | 184 | 0.18 / 862.81 | 3 | 3 |
2 | 3 | 951.60 | -1 | 14.20 | 446 | 0 | 0.00 / 862.81 | 3 | 3 |
3 | 12 | 1116.52 | 9 | 9.17 | 1952 | 161 | 0.34 / 862.97 | 2 | 3 |
4 | 12 | 2002.32 | 73 | 7.26 | 3243 | 1719 | 2.06 / 864.69 | 2 | 3 |
5 | 7 | 1996.60 | 25 | 10.56 | 3267 | 862 | 2.93 / 865.55 | 3 | 3 |
6 | 13 | 1733.68 | 32 | 12.41 | 2915 | 1158 | 4.08 / 866.71 | 2 | 3 |
7 | 13 | 1003.48 | 32 | 13.17 | 1823 | 768 | 4.85 / 867.48 | 2 | 3 |
8 | 13 | 100.60 | 32 | 14.13 | 480 | 217 | 5.07 / 867.70 | 2 | 3 |
9 | 8 | 0.04 | 180 | 14.29 | 310 | 797 | 5.87 / 868.49 | 3 | 6 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 29 | 14.23 | 461 | 190 | 0.19 / 857.11 | 3 | 3 |
2 | 12 | 1118.84 | 10 | 9.59 | 1960 | 188 | 0.38 / 857.30 | 2 | 3 |
3 | 12 | 1984.80 | 73 | 7.50 | 3200 | 1752 | 2.13 / 859.05 | 2 | 3 |
4 | 7 | 1978.12 | 25 | 10.56 | 3258 | 860 | 2.99 / 859.91 | 3 | 3 |
5 | 13 | 1571.08 | 38 | 12.42 | 2634 | 1243 | 4.23 / 861.16 | 2 | 3 |
6 | 13 | 680.40 | 38 | 13.44 | 1308 | 668 | 4.90 / 861.82 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.28 | 312 | 802 | 5.70 / 862.63 | 3 | 8 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 29 | 14.25 | 450 | 186 | 0.19 / 851.40 | 3 | 3 |
2 | 12 | 1097.20 | 10 | 9.70 | 1927 | 187 | 0.37 / 851.59 | 2 | 3 |
3 | 12 | 1986.68 | 73 | 7.42 | 3202 | 1734 | 2.11 / 853.33 | 2 | 3 |
4 | 7 | 1979.08 | 25 | 10.57 | 3249 | 859 | 2.97 / 854.18 | 3 | 3 |
5 | 13 | 1442.92 | 38 | 12.62 | 2419 | 1160 | 4.13 / 855.34 | 2 | 3 |
6 | 13 | 578.52 | 38 | 13.57 | 1147 | 591 | 4.72 / 855.94 | 2 | 3 |
7 | 13 | 25.12 | 38 | 14.27 | 354 | 192 | 4.91 / 856.13 | 3 | 3 |
8 | 8 | -0.12 | 180 | 14.29 | 309 | 795 | 5.70 / 856.92 | 3 | 12 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 29 | 14.26 | 447 | 185 | 0.18 / 845.45 | 3 | 3 |
2 | 12 | 1124.36 | 10 | 9.62 | 1988 | 191 | 0.38 / 845.64 | 2 | 3 |
3 | 12 | 1994.64 | 73 | 7.44 | 3239 | 1759 | 2.14 / 847.40 | 2 | 3 |
4 | 7 | 1987.76 | 25 | 10.60 | 3265 | 865 | 3.00 / 848.26 | 3 | 3 |
5 | 13 | 1593.04 | 38 | 12.46 | 2671 | 1265 | 4.27 / 849.53 | 2 | 3 |
6 | 13 | 712.52 | 38 | 13.42 | 1364 | 696 | 4.96 / 850.22 | 2 | 3 |
7 | 13 | 39.76 | 38 | 14.24 | 375 | 203 | 5.16 / 850.43 | 2 | 3 |
8 | 8 | -0.12 | 180 | 14.30 | 308 | 793 | 5.96 / 851.22 | 3 | 13 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 29 | 14.26 | 452 | 187 | 0.19 / 839.55 | 3 | 3 |
2 | 12 | 1116.40 | 10 | 9.71 | 1958 | 190 | 0.38 / 839.74 | 2 | 3 |
3 | 12 | 1992.04 | 66 | 7.47 | 3226 | 1590 | 1.97 / 841.33 | 2 | 3 |
4 | 7 | 1984.48 | 25 | 10.56 | 3261 | 861 | 2.83 / 842.19 | 3 | 3 |
5 | 13 | 1700.68 | 38 | 12.30 | 2840 | 1327 | 4.16 / 843.52 | 2 | 3 |
6 | 13 | 803.28 | 38 | 13.33 | 1483 | 751 | 4.91 / 844.27 | 2 | 3 |
7 | 13 | 34.04 | 38 | 14.25 | 368 | 199 | 5.11 / 844.47 | 3 | 3 |
8 | 8 | -0.16 | 180 | 14.31 | 308 | 793 | 5.90 / 845.26 | 3 | 10 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 29 | 14.27 | 448 | 185 | 0.19 / 833.60 | 3 | 3 |
2 | 12 | 1107.12 | 10 | 9.56 | 1934 | 185 | 0.37 / 833.78 | 2 | 3 |
3 | 12 | 1993.72 | 66 | 7.61 | 3205 | 1610 | 1.98 / 835.39 | 2 | 3 |
4 | 7 | 1987.40 | 25 | 10.65 | 3257 | 867 | 2.85 / 836.26 | 3 | 3 |
5 | 13 | 1721.72 | 38 | 12.29 | 2873 | 1342 | 4.19 / 837.60 | 2 | 3 |
6 | 13 | 811.28 | 38 | 13.33 | 1488 | 754 | 4.94 / 838.35 | 2 | 3 |
7 | 13 | 56.88 | 38 | 14.21 | 408 | 220 | 5.16 / 838.57 | 2 | 3 |
8 | 8 | -0.24 | 180 | 14.31 | 306 | 788 | 5.95 / 839.36 | 3 | 11 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 29 | 14.27 | 450 | 186 | 0.19 / 827.56 | 3 | 3 |
2 | 12 | 1124.92 | 10 | 9.30 | 1982 | 184 | 0.37 / 827.74 | 2 | 3 |
3 | 12 | 2004.12 | 66 | 7.87 | 3249 | 1688 | 2.06 / 829.43 | 2 | 3 |
4 | 7 | 1998.44 | 25 | 10.68 | 3269 | 873 | 2.93 / 830.30 | 3 | 3 |
5 | 13 | 1727.32 | 38 | 12.34 | 2866 | 1344 | 4.27 / 831.65 | 2 | 3 |
6 | 13 | 807.80 | 38 | 13.34 | 1483 | 752 | 5.03 / 832.40 | 2 | 3 |
7 | 13 | 50.60 | 38 | 14.21 | 400 | 216 | 5.24 / 832.61 | 2 | 3 |
8 | 8 | -0.04 | 180 | 14.29 | 310 | 797 | 6.04 / 833.41 | 3 | 9 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 29 | 14.27 | 457 | 189 | 0.19 / 821.68 | 3 | 3 |
2 | 12 | 1119.80 | 10 | 10.08 | 1961 | 198 | 0.39 / 821.88 | 2 | 3 |
3 | 12 | 2001.48 | 66 | 7.99 | 3248 | 1713 | 2.10 / 823.59 | 2 | 3 |
4 | 7 | 1995.16 | 25 | 10.66 | 3285 | 875 | 2.98 / 824.46 | 3 | 3 |
5 | 13 | 1590.24 | 38 | 12.48 | 2668 | 1265 | 4.24 / 825.73 | 2 | 3 |
6 | 13 | 675.72 | 38 | 13.49 | 1287 | 660 | 4.90 / 826.39 | 2 | 3 |
7 | 13 | 29.88 | 38 | 14.27 | 360 | 195 | 5.10 / 826.58 | 3 | 3 |
8 | 8 | -0.20 | 180 | 14.30 | 306 | 788 | 5.88 / 827.37 | 3 | 13 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 28 | 14.28 | 452 | 181 | 0.18 / 815.62 | 3 | 3 |
2 | 12 | 1128.00 | 8 | 8.93 | 1975 | 141 | 0.32 / 815.76 | 2 | 3 |
3 | 12 | 2002.40 | 61 | 7.99 | 3245 | 1582 | 1.90 / 817.34 | 2 | 3 |
4 | 7 | 1998.64 | 25 | 10.70 | 3282 | 878 | 2.78 / 818.22 | 3 | 3 |
5 | 13 | 1864.32 | 38 | 12.13 | 3088 | 1423 | 4.20 / 819.64 | 2 | 3 |
6 | 13 | 919.04 | 38 | 13.23 | 1654 | 832 | 5.04 / 820.48 | 2 | 3 |
7 | 13 | 51.36 | 38 | 14.23 | 393 | 213 | 5.25 / 820.69 | 2 | 3 |
8 | 8 | -0.04 | 180 | 14.29 | 311 | 800 | 6.05 / 821.49 | 3 | 9 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 28 | 14.29 | 450 | 180 | 0.18 / 809.71 | 3 | 3 |
2 | 12 | 1118.88 | 8 | 9.61 | 1975 | 152 | 0.33 / 809.86 | 2 | 3 |
3 | 12 | 2003.84 | 61 | 8.11 | 3267 | 1616 | 1.95 / 811.48 | 2 | 3 |
4 | 7 | 1999.16 | 25 | 10.70 | 3283 | 878 | 2.83 / 812.36 | 3 | 3 |
5 | 13 | 1729.64 | 38 | 12.32 | 2892 | 1354 | 4.18 / 813.71 | 2 | 3 |
6 | 13 | 795.80 | 38 | 13.36 | 1451 | 737 | 4.92 / 814.45 | 2 | 3 |
7 | 13 | 30.20 | 38 | 14.27 | 365 | 198 | 5.11 / 814.64 | 2 | 3 |
8 | 8 | -0.08 | 180 | 14.29 | 309 | 795 | 5.91 / 815.44 | 3 | 7 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 28 | 14.28 | 449 | 180 | 0.18 / 803.88 | 3 | 3 |
2 | 12 | 1119.72 | 7 | 9.11 | 1954 | 125 | 0.30 / 804.00 | 2 | 3 |
3 | 12 | 2004.76 | 57 | 8.17 | 3246 | 1512 | 1.82 / 805.51 | 2 | 3 |
4 | 7 | 2000.76 | 25 | 10.75 | 3288 | 884 | 2.70 / 806.40 | 3 | 3 |
5 | 13 | 1741.44 | 38 | 12.32 | 2902 | 1359 | 4.06 / 807.76 | 2 | 3 |
6 | 13 | 845.72 | 38 | 13.31 | 1524 | 771 | 4.83 / 808.53 | 2 | 3 |
7 | 13 | 36.64 | 38 | 14.25 | 376 | 204 | 5.03 / 808.73 | 2 | 3 |
8 | 8 | -0.08 | 180 | 14.28 | 311 | 799 | 5.83 / 809.53 | 3 | 9 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 28 | 14.25 | 455 | 182 | 0.18 / 798.03 | 3 | 3 |
2 | 12 | 1136.80 | 7 | 8.73 | 1992 | 122 | 0.30 / 798.16 | 2 | 3 |
3 | 12 | 2002.80 | 57 | 8.37 | 3255 | 1553 | 1.86 / 799.71 | 2 | 3 |
4 | 7 | 1998.00 | 25 | 10.76 | 3269 | 879 | 2.74 / 800.59 | 3 | 3 |
5 | 13 | 1725.00 | 38 | 12.35 | 2877 | 1350 | 4.09 / 801.94 | 2 | 3 |
6 | 13 | 806.96 | 38 | 13.34 | 1493 | 757 | 4.84 / 802.69 | 2 | 3 |
7 | 13 | 39.56 | 38 | 14.25 | 384 | 208 | 5.05 / 802.90 | 2 | 3 |
8 | 8 | 0.00 | 180 | 14.30 | 309 | 795 | 5.85 / 803.70 | 3 | 9 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 28 | 14.27 | 455 | 182 | 0.18 / 792.23 | 3 | 3 |
2 | 12 | 1119.48 | 7 | 8.90 | 1955 | 122 | 0.30 / 792.35 | 2 | 3 |
3 | 12 | 2000.32 | 57 | 8.61 | 3247 | 1594 | 1.90 / 793.94 | 2 | 3 |
4 | 7 | 1996.00 | 25 | 10.76 | 3270 | 880 | 2.78 / 794.82 | 3 | 3 |
5 | 13 | 1726.08 | 38 | 12.33 | 2876 | 1348 | 4.12 / 796.17 | 2 | 3 |
6 | 13 | 686.40 | 38 | 13.45 | 1343 | 686 | 4.81 / 796.86 | 2 | 3 |
7 | 13 | 35.80 | 38 | 14.25 | 369 | 200 | 5.01 / 797.06 | 2 | 3 |
8 | 8 | -0.12 | 180 | 14.28 | 309 | 794 | 5.80 / 797.85 | 3 | 5 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 28 | 14.26 | 446 | 178 | 0.18 / 786.50 | 3 | 3 |
2 | 12 | 1125.36 | 5 | 7.88 | 1936 | 76 | 0.25 / 786.58 | 2 | 3 |
3 | 12 | 2000.60 | 54 | 8.48 | 3229 | 1479 | 1.73 / 788.05 | 2 | 3 |
4 | 7 | 1996.92 | 25 | 10.77 | 3287 | 885 | 2.62 / 788.94 | 3 | 3 |
5 | 13 | 1727.68 | 38 | 12.33 | 2892 | 1355 | 3.97 / 790.29 | 2 | 3 |
6 | 13 | 831.20 | 38 | 13.32 | 1532 | 775 | 4.75 / 791.07 | 2 | 3 |
7 | 13 | 17.40 | 38 | 14.29 | 340 | 185 | 4.93 / 791.25 | 3 | 3 |
8 | 8 | -0.08 | 180 | 14.26 | 309 | 793 | 5.73 / 792.05 | 3 | 7 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 28 | 14.26 | 460 | 184 | 0.18 / 780.79 | 3 | 3 |
2 | 12 | 1126.56 | 5 | 8.32 | 1952 | 81 | 0.26 / 780.87 | 2 | 3 |
3 | 12 | 2002.52 | 54 | 8.63 | 3235 | 1508 | 1.77 / 782.38 | 2 | 3 |
4 | 7 | 1998.24 | 25 | 10.80 | 3282 | 886 | 2.66 / 783.26 | 3 | 3 |
5 | 13 | 1721.64 | 38 | 12.37 | 2826 | 1328 | 3.99 / 784.59 | 2 | 3 |
6 | 13 | 805.68 | 38 | 13.35 | 1464 | 743 | 4.73 / 785.33 | 2 | 3 |
7 | 13 | 30.64 | 38 | 14.28 | 359 | 195 | 4.92 / 785.53 | 2 | 3 |
8 | 8 | -0.12 | 180 | 14.28 | 308 | 792 | 5.72 / 786.32 | 3 | 6 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 28 | 14.25 | 461 | 184 | 0.18 / 774.97 | 3 | 3 |
2 | 12 | 1127.44 | 5 | 8.36 | 1959 | 82 | 0.27 / 775.05 | 2 | 3 |
3 | 12 | 2003.48 | 54 | 8.84 | 3245 | 1549 | 1.81 / 776.60 | 2 | 3 |
4 | 7 | 1999.76 | 25 | 10.81 | 3288 | 889 | 2.70 / 777.49 | 3 | 3 |
5 | 13 | 1731.56 | 38 | 12.33 | 2889 | 1354 | 4.06 / 778.84 | 2 | 3 |
6 | 13 | 820.28 | 38 | 13.32 | 1518 | 768 | 4.83 / 779.61 | 2 | 3 |
7 | 13 | 25.52 | 38 | 14.27 | 358 | 194 | 5.02 / 779.80 | 3 | 3 |
8 | 8 | 0.08 | 180 | 14.27 | 313 | 804 | 5.82 / 780.61 | 3 | 8 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 28 | 14.26 | 463 | 185 | 0.18 / 769.48 | 3 | 3 |
2 | 12 | 1124.40 | 5 | 9.34 | 1962 | 92 | 0.28 / 769.57 | 2 | 3 |
3 | 12 | 2002.72 | 54 | 9.06 | 3231 | 1581 | 1.86 / 771.15 | 2 | 3 |
4 | 7 | 1998.12 | 25 | 10.83 | 3290 | 891 | 2.75 / 772.04 | 3 | 3 |
5 | 13 | 1592.60 | 38 | 12.48 | 2674 | 1268 | 4.02 / 773.31 | 2 | 3 |
6 | 13 | 687.04 | 38 | 13.46 | 1308 | 669 | 4.69 / 773.98 | 2 | 3 |
7 | 8 | 0.04 | 180 | 14.26 | 313 | 803 | 5.49 / 774.78 | 3 | 11 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 28 | 14.23 | 460 | 183 | 0.18 / 763.77 | 3 | 3 |
2 | 12 | 1121.80 | 3 | 6.17 | 2182 | 40 | 0.22 / 763.81 | 2 | 3 |
3 | 12 | 2005.76 | 51 | 9.00 | 3242 | 1488 | 1.71 / 765.30 | 2 | 3 |
4 | 7 | 2002.00 | 25 | 10.86 | 3285 | 892 | 2.60 / 766.19 | 3 | 3 |
5 | 13 | 1731.80 | 38 | 12.36 | 2855 | 1341 | 3.94 / 767.53 | 2 | 3 |
6 | 13 | 837.04 | 38 | 13.32 | 1509 | 764 | 4.71 / 768.30 | 2 | 3 |
7 | 13 | 34.40 | 38 | 14.26 | 371 | 201 | 4.91 / 768.50 | 2 | 3 |
8 | 8 | -0.04 | 180 | 14.27 | 310 | 796 | 5.71 / 769.29 | 3 | 6 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 28 | 14.23 | 465 | 185 | 0.19 / 757.86 | 3 | 3 |
2 | 12 | 1126.28 | 3 | 7.75 | 1969 | 46 | 0.23 / 757.90 | 2 | 3 |
3 | 12 | 2008.20 | 51 | 9.17 | 3220 | 1506 | 1.74 / 759.41 | 2 | 3 |
4 | 7 | 2005.72 | 25 | 10.90 | 3278 | 893 | 2.63 / 760.30 | 3 | 3 |
5 | 13 | 1871.92 | 38 | 12.13 | 3099 | 1428 | 4.06 / 761.73 | 2 | 3 |
6 | 13 | 955.68 | 38 | 13.18 | 1716 | 859 | 4.92 / 762.59 | 2 | 3 |
7 | 13 | 23.60 | 38 | 14.27 | 357 | 194 | 5.11 / 762.78 | 2 | 3 |
8 | 8 | -0.04 | 180 | 14.26 | 313 | 803 | 5.92 / 763.59 | 3 | 10 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 28 | 14.23 | 454 | 181 | 0.18 / 752.28 | 3 | 3 |
2 | 12 | 2003.40 | 51 | 8.79 | 3137 | 1406 | 1.59 / 753.69 | 2 | 3 |
3 | 7 | 2000.28 | 24 | 10.92 | 3277 | 859 | 2.45 / 754.55 | 3 | 3 |
4 | 13 | 1741.08 | 38 | 12.30 | 2896 | 1354 | 3.80 / 755.90 | 2 | 3 |
5 | 13 | 846.44 | 38 | 13.28 | 1561 | 788 | 4.59 / 756.69 | 2 | 3 |
6 | 13 | 7.44 | 38 | 14.31 | 325 | 177 | 4.76 / 756.87 | 3 | 3 |
7 | 8 | 0.32 | 180 | 14.24 | 315 | 807 | 5.57 / 757.67 | 3 | 14 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 28 | 14.23 | 459 | 183 | 0.18 / 746.84 | 3 | 3 |
2 | 12 | 2004.32 | 51 | 8.90 | 3170 | 1439 | 1.62 / 748.28 | 2 | 3 |
3 | 7 | 2001.08 | 25 | 10.91 | 3267 | 891 | 2.51 / 749.17 | 3 | 3 |
4 | 13 | 1740.60 | 38 | 12.32 | 2883 | 1350 | 3.86 / 750.52 | 2 | 3 |
5 | 13 | 835.24 | 38 | 13.29 | 1540 | 778 | 4.64 / 751.30 | 2 | 3 |
6 | 8 | -0.36 | 180 | 14.25 | 312 | 800 | 5.44 / 752.10 | 3 | 9 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 28 | 14.24 | 460 | 183 | 0.18 / 741.04 | 3 | 3 |
2 | 12 | 2003.52 | 51 | 9.09 | 3160 | 1465 | 1.65 / 742.51 | 2 | 3 |
3 | 7 | 2000.76 | 25 | 10.89 | 3280 | 893 | 2.54 / 743.40 | 3 | 3 |
4 | 13 | 1868.36 | 38 | 12.13 | 3099 | 1428 | 3.97 / 744.83 | 2 | 3 |
5 | 13 | 925.96 | 38 | 13.20 | 1674 | 840 | 4.81 / 745.67 | 2 | 3 |
6 | 13 | 24.28 | 38 | 14.27 | 355 | 193 | 5.00 / 745.86 | 3 | 3 |
7 | 8 | 0.04 | 180 | 14.25 | 312 | 800 | 5.80 / 746.66 | 3 | 9 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 28 | 14.23 | 468 | 186 | 0.19 / 735.47 | 3 | 3 |
2 | 12 | 2006.92 | 51 | 9.24 | 3173 | 1495 | 1.68 / 736.96 | 2 | 3 |
3 | 7 | 2003.20 | 25 | 10.88 | 3273 | 890 | 2.57 / 737.85 | 3 | 3 |
4 | 13 | 1729.08 | 38 | 12.33 | 2867 | 1343 | 3.92 / 739.20 | 2 | 3 |
5 | 13 | 947.24 | 38 | 13.16 | 1705 | 853 | 4.77 / 740.05 | 2 | 3 |
6 | 8 | 0.24 | 180 | 14.25 | 315 | 808 | 5.58 / 740.86 | 2 | 8 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 28 | 14.22 | 464 | 185 | 0.18 / 729.96 | 3 | 3 |
2 | 12 | 2005.92 | 51 | 9.30 | 3169 | 1503 | 1.69 / 731.46 | 2 | 3 |
3 | 7 | 2002.12 | 25 | 10.92 | 3275 | 894 | 2.58 / 732.36 | 3 | 3 |
4 | 13 | 1738.24 | 38 | 12.31 | 2903 | 1358 | 3.94 / 733.71 | 2 | 3 |
5 | 13 | 827.48 | 38 | 13.30 | 1513 | 765 | 4.70 / 734.48 | 2 | 3 |
6 | 8 | 0.00 | 180 | 14.25 | 313 | 803 | 5.51 / 735.28 | 3 | 5 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 28 | 14.21 | 473 | 188 | 0.19 / 724.60 | 3 | 3 |
2 | 12 | 2006.92 | 51 | 9.38 | 3202 | 1532 | 1.72 / 726.13 | 2 | 3 |
3 | 7 | 2003.20 | 25 | 10.91 | 3280 | 895 | 2.61 / 727.02 | 3 | 3 |
4 | 13 | 1596.76 | 38 | 12.49 | 2666 | 1265 | 3.88 / 728.29 | 2 | 3 |
5 | 13 | 715.52 | 38 | 13.42 | 1339 | 683 | 4.56 / 728.97 | 2 | 3 |
6 | 8 | -0.24 | 180 | 14.24 | 313 | 802 | 5.37 / 729.77 | 3 | 11 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 28 | 14.21 | 465 | 185 | 0.19 / 719.05 | 3 | 3 |
2 | 12 | 2003.72 | 49 | 9.43 | 3204 | 1480 | 1.67 / 720.53 | 2 | 3 |
3 | 7 | 2000.68 | 25 | 10.97 | 3264 | 895 | 2.56 / 721.43 | 3 | 3 |
4 | 13 | 1866.72 | 38 | 12.14 | 3094 | 1427 | 3.99 / 722.85 | 2 | 3 |
5 | 13 | 800.32 | 38 | 13.32 | 1478 | 748 | 4.74 / 723.60 | 2 | 3 |
6 | 8 | 0.24 | 180 | 14.23 | 316 | 809 | 5.55 / 724.41 | 3 | 8 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 28 | 14.21 | 469 | 187 | 0.19 / 713.39 | 3 | 3 |
2 | 12 | 2002.04 | 49 | 9.64 | 3186 | 1505 | 1.69 / 714.89 | 2 | 3 |
3 | 7 | 1997.36 | 25 | 10.98 | 3272 | 898 | 2.59 / 715.79 | 3 | 3 |
4 | 13 | 1717.04 | 38 | 12.36 | 2853 | 1340 | 3.93 / 717.13 | 2 | 3 |
5 | 13 | 802.96 | 38 | 13.32 | 1490 | 754 | 4.68 / 717.89 | 2 | 3 |
6 | 13 | 8.28 | 38 | 14.29 | 329 | 179 | 4.86 / 718.06 | 2 | 3 |
7 | 8 | 0.04 | 180 | 14.21 | 313 | 801 | 5.66 / 718.86 | 3 | 9 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 28 | 14.23 | 469 | 187 | 0.19 / 708.06 | 3 | 3 |
2 | 12 | 2002.44 | 49 | 9.70 | 3184 | 1513 | 1.70 / 709.57 | 2 | 3 |
3 | 7 | 1997.96 | 25 | 10.97 | 3271 | 897 | 2.60 / 710.47 | 3 | 3 |
4 | 13 | 1588.84 | 38 | 12.49 | 2638 | 1252 | 3.85 / 711.72 | 2 | 3 |
5 | 13 | 691.84 | 38 | 13.43 | 1331 | 679 | 4.53 / 712.40 | 2 | 3 |
6 | 8 | 0.08 | 180 | 14.23 | 314 | 804 | 5.33 / 713.20 | 3 | 9 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 28 | 14.22 | 466 | 186 | 0.19 / 702.71 | 3 | 3 |
2 | 12 | 2005.60 | 49 | 9.73 | 3198 | 1525 | 1.71 / 704.23 | 2 | 3 |
3 | 7 | 2001.52 | 25 | 10.97 | 3273 | 898 | 2.61 / 705.13 | 3 | 3 |
4 | 13 | 1597.12 | 38 | 12.48 | 2663 | 1263 | 3.87 / 706.39 | 2 | 3 |
5 | 13 | 681.60 | 38 | 13.43 | 1324 | 676 | 4.55 / 707.07 | 2 | 3 |
6 | 8 | 0.08 | 180 | 14.23 | 313 | 802 | 5.35 / 707.87 | 3 | 6 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 28 | 14.23 | 469 | 187 | 0.19 / 697.09 | 3 | 3 |
2 | 12 | 2000.52 | 49 | 9.83 | 3208 | 1545 | 1.73 / 698.63 | 2 | 3 |
3 | 7 | 1996.32 | 25 | 10.98 | 3265 | 896 | 2.63 / 699.53 | 3 | 3 |
4 | 13 | 1594.88 | 38 | 12.50 | 2621 | 1245 | 3.87 / 700.77 | 2 | 3 |
5 | 13 | 818.96 | 38 | 13.31 | 1500 | 759 | 4.63 / 701.53 | 2 | 3 |
6 | 13 | 24.96 | 38 | 14.26 | 355 | 192 | 4.82 / 701.72 | 2 | 3 |
7 | 8 | -0.28 | 180 | 14.22 | 311 | 796 | 5.62 / 702.52 | 3 | 13 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 28 | 14.24 | 458 | 183 | 0.18 / 691.81 | 3 | 3 |
2 | 12 | 2004.52 | 49 | 9.89 | 3223 | 1562 | 1.74 / 693.38 | 2 | 3 |
3 | 7 | 2000.12 | 25 | 10.96 | 3288 | 901 | 2.65 / 694.28 | 3 | 3 |
4 | 13 | 1592.00 | 38 | 12.46 | 2659 | 1259 | 3.90 / 695.54 | 2 | 3 |
5 | 13 | 561.84 | 38 | 13.59 | 1102 | 569 | 4.47 / 696.11 | 2 | 3 |
6 | 8 | 0.04 | 180 | 14.23 | 310 | 794 | 5.27 / 696.90 | 3 | 8 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 28 | 14.24 | 459 | 183 | 0.18 / 686.47 | 3 | 3 |
2 | 12 | 2000.40 | 49 | 9.94 | 3217 | 1567 | 1.75 / 688.04 | 2 | 3 |
3 | 7 | 1996.16 | 25 | 10.97 | 3274 | 898 | 2.65 / 688.93 | 3 | 3 |
4 | 13 | 1583.00 | 38 | 12.49 | 2623 | 1245 | 3.89 / 690.18 | 2 | 3 |
5 | 13 | 661.36 | 38 | 13.45 | 1287 | 658 | 4.55 / 690.84 | 2 | 3 |
6 | 8 | 0.04 | 180 | 14.23 | 311 | 797 | 5.35 / 691.63 | 3 | 9 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 28 | 14.26 | 466 | 186 | 0.19 / 681.10 | 3 | 3 |
2 | 12 | 2002.60 | 49 | 9.92 | 3239 | 1574 | 1.76 / 682.68 | 2 | 3 |
3 | 7 | 1999.00 | 25 | 10.97 | 3275 | 898 | 2.66 / 683.58 | 3 | 3 |
4 | 13 | 1588.88 | 38 | 12.49 | 2638 | 1252 | 3.91 / 684.83 | 2 | 3 |
5 | 13 | 680.32 | 38 | 13.46 | 1287 | 658 | 4.57 / 685.49 | 2 | 3 |
6 | 8 | 0.20 | 180 | 14.23 | 312 | 799 | 5.37 / 686.29 | 3 | 11 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 28 | 14.27 | 465 | 186 | 0.19 / 675.75 | 3 | 3 |
2 | 12 | 2004.24 | 49 | 9.86 | 3231 | 1561 | 1.75 / 677.31 | 2 | 3 |
3 | 7 | 1999.96 | 25 | 10.96 | 3276 | 898 | 2.64 / 678.20 | 3 | 3 |
4 | 13 | 1578.92 | 38 | 12.48 | 2645 | 1254 | 3.90 / 679.46 | 2 | 3 |
5 | 13 | 656.08 | 38 | 13.47 | 1276 | 653 | 4.55 / 680.11 | 2 | 3 |
6 | 8 | -0.20 | 180 | 14.24 | 314 | 805 | 5.36 / 680.92 | 2 | 8 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 28 | 14.26 | 452 | 180 | 0.18 / 670.70 | 3 | 3 |
2 | 7 | 2002.64 | 53 | 9.86 | 3272 | 1710 | 1.89 / 672.41 | 3 | 3 |
3 | 13 | 1881.60 | 25 | 12.43 | 3121 | 970 | 2.86 / 673.38 | 2 | 3 |
4 | 13 | 1471.12 | 25 | 12.85 | 2501 | 803 | 3.66 / 674.18 | 2 | 3 |
5 | 13 | 628.64 | 25 | 13.58 | 1261 | 428 | 4.09 / 674.61 | 2 | 3 |
6 | 13 | 84.16 | 25 | 14.19 | 449 | 159 | 4.25 / 674.77 | 3 | 3 |
7 | 8 | 0.16 | 180 | 14.25 | 309 | 793 | 5.04 / 675.56 | 3 | 18 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 28 | 14.28 | 452 | 181 | 0.18 / 665.75 | 3 | 3 |
2 | 7 | 2005.88 | 52 | 9.89 | 3270 | 1682 | 1.86 / 667.43 | 3 | 3 |
3 | 13 | 1891.72 | 25 | 12.40 | 3140 | 973 | 2.84 / 668.40 | 2 | 3 |
4 | 13 | 1356.12 | 25 | 12.95 | 2302 | 745 | 3.58 / 669.15 | 2 | 3 |
5 | 13 | 667.24 | 25 | 13.55 | 1307 | 443 | 4.02 / 669.59 | 2 | 3 |
6 | 13 | 54.36 | 25 | 14.23 | 397 | 141 | 4.17 / 669.73 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.24 | 306 | 784 | 4.95 / 670.52 | 3 | 7 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 28 | 14.27 | 450 | 180 | 0.18 / 660.80 | 3 | 3 |
2 | 3 | 972.36 | -1 | 14.27 | 450 | 0 | 0.00 / 660.80 | 3 | 3 |
3 | 3 | 1035.96 | 1 | 12.70 | 1904 | 24 | 0.20 / 660.83 | 2 | 3 |
4 | 7 | 2001.88 | 52 | 10.06 | 3264 | 1707 | 1.91 / 662.54 | 3 | 3 |
5 | 13 | 1883.24 | 25 | 12.43 | 3128 | 972 | 2.88 / 663.51 | 2 | 3 |
6 | 13 | 1218.00 | 25 | 13.05 | 2100 | 685 | 3.57 / 664.19 | 2 | 3 |
7 | 13 | 689.72 | 25 | 13.54 | 1325 | 449 | 4.02 / 664.64 | 2 | 3 |
8 | 13 | 57.04 | 25 | 14.23 | 401 | 143 | 4.16 / 664.78 | 2 | 3 |
9 | 8 | 0.16 | 180 | 14.26 | 305 | 783 | 4.94 / 665.57 | 3 | 7 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 28 | 14.29 | 453 | 181 | 0.18 / 655.61 | 3 | 3 |
2 | 7 | 2004.16 | 52 | 10.04 | 3255 | 1699 | 1.88 / 657.30 | 3 | 3 |
3 | 13 | 1889.04 | 25 | 12.40 | 3138 | 973 | 2.85 / 658.28 | 2 | 3 |
4 | 13 | 1483.12 | 25 | 12.84 | 2509 | 805 | 3.66 / 659.08 | 2 | 3 |
5 | 13 | 761.32 | 25 | 13.47 | 1427 | 481 | 4.14 / 659.56 | 2 | 3 |
6 | 13 | 79.36 | 25 | 14.20 | 441 | 157 | 4.30 / 659.72 | 2 | 3 |
7 | 13 | 18.84 | 25 | 14.30 | 340 | 122 | 4.42 / 659.84 | 3 | 3 |
8 | 8 | -0.20 | 180 | 14.22 | 306 | 783 | 5.20 / 660.62 | 3 | 8 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 28 | 14.30 | 443 | 177 | 0.18 / 650.54 | 3 | 3 |
2 | 7 | 2002.40 | 52 | 10.08 | 3268 | 1713 | 1.89 / 652.25 | 3 | 3 |
3 | 13 | 1877.76 | 25 | 12.40 | 3107 | 963 | 2.85 / 653.22 | 2 | 3 |
4 | 13 | 1446.76 | 25 | 12.89 | 2441 | 787 | 3.64 / 654.00 | 2 | 3 |
5 | 13 | 723.80 | 25 | 13.49 | 1421 | 479 | 4.12 / 654.48 | 2 | 3 |
6 | 13 | 61.92 | 25 | 14.22 | 419 | 149 | 4.27 / 654.63 | 2 | 3 |
7 | 8 | -0.04 | 180 | 14.23 | 310 | 794 | 5.06 / 655.42 | 3 | 13 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 28 | 14.31 | 445 | 178 | 0.18 / 645.52 | 3 | 3 |
2 | 7 | 2006.96 | 52 | 10.08 | 3282 | 1720 | 1.90 / 647.24 | 2 | 3 |
3 | 13 | 1891.36 | 25 | 12.40 | 3140 | 973 | 2.87 / 648.22 | 2 | 3 |
4 | 13 | 1466.80 | 25 | 12.85 | 2484 | 798 | 3.67 / 649.01 | 2 | 3 |
5 | 13 | 616.48 | 25 | 13.61 | 1221 | 415 | 4.09 / 649.43 | 2 | 3 |
6 | 13 | 78.80 | 25 | 14.20 | 436 | 155 | 4.24 / 649.58 | 2 | 3 |
7 | 8 | 0.12 | 180 | 14.26 | 303 | 778 | 5.02 / 650.36 | 3 | 7 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 28 | 14.29 | 449 | 180 | 0.18 / 640.48 | 3 | 3 |
2 | 7 | 2003.52 | 53 | 10.09 | 3274 | 1751 | 1.93 / 642.23 | 3 | 3 |
3 | 13 | 1880.44 | 25 | 12.40 | 3125 | 969 | 2.90 / 643.20 | 2 | 3 |
4 | 13 | 1314.80 | 25 | 12.97 | 2267 | 735 | 3.63 / 643.94 | 2 | 3 |
5 | 13 | 751.68 | 25 | 13.49 | 1402 | 473 | 4.11 / 644.41 | 2 | 3 |
6 | 13 | 68.92 | 25 | 14.23 | 422 | 150 | 4.26 / 644.56 | 2 | 3 |
7 | 8 | -0.12 | 180 | 14.26 | 305 | 783 | 5.04 / 645.34 | 3 | 12 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 28 | 14.30 | 450 | 180 | 0.18 / 635.46 | 3 | 3 |
2 | 7 | 2002.24 | 53 | 10.19 | 3263 | 1762 | 1.94 / 637.22 | 3 | 3 |
3 | 13 | 1881.80 | 25 | 12.41 | 3128 | 970 | 2.91 / 638.19 | 2 | 3 |
4 | 13 | 1218.44 | 25 | 13.05 | 2120 | 692 | 3.60 / 638.88 | 2 | 3 |
5 | 13 | 795.24 | 25 | 13.46 | 1473 | 496 | 4.10 / 639.38 | 2 | 3 |
6 | 13 | 47.08 | 25 | 14.25 | 385 | 137 | 4.24 / 639.52 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.24 | 307 | 787 | 5.02 / 640.30 | 3 | 10 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 28 | 14.31 | 454 | 182 | 0.18 / 630.41 | 3 | 3 |
2 | 7 | 2003.72 | 52 | 10.26 | 3275 | 1747 | 1.93 / 632.15 | 2 | 3 |
3 | 13 | 1883.32 | 25 | 12.40 | 3135 | 972 | 2.90 / 633.13 | 2 | 3 |
4 | 13 | 1332.08 | 25 | 12.97 | 2271 | 736 | 3.64 / 633.86 | 2 | 3 |
5 | 13 | 755.48 | 25 | 13.47 | 1434 | 483 | 4.12 / 634.34 | 2 | 3 |
6 | 13 | 63.84 | 25 | 14.21 | 421 | 150 | 4.27 / 634.49 | 3 | 3 |
7 | 8 | 0.36 | 180 | 14.25 | 306 | 785 | 5.05 / 635.28 | 3 | 16 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 28 | 14.31 | 446 | 179 | 0.18 / 625.34 | 3 | 3 |
2 | 7 | 2003.84 | 53 | 10.31 | 3263 | 1783 | 1.96 / 627.13 | 3 | 3 |
3 | 13 | 1879.80 | 25 | 12.39 | 3128 | 969 | 2.93 / 628.09 | 2 | 3 |
4 | 13 | 1321.12 | 25 | 12.99 | 2257 | 733 | 3.66 / 628.83 | 2 | 3 |
5 | 13 | 731.56 | 25 | 13.52 | 1359 | 459 | 4.12 / 629.29 | 2 | 3 |
6 | 13 | 61.12 | 25 | 14.22 | 416 | 148 | 4.27 / 629.43 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.25 | 308 | 790 | 5.06 / 630.22 | 3 | 13 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 28 | 14.32 | 443 | 178 | 0.18 / 620.13 | 3 | 3 |
2 | 7 | 2005.08 | 52 | 10.33 | 3277 | 1760 | 1.94 / 621.89 | 3 | 3 |
3 | 13 | 1898.00 | 25 | 12.42 | 3152 | 979 | 2.92 / 622.87 | 2 | 3 |
4 | 13 | 1462.84 | 25 | 12.85 | 2485 | 798 | 3.71 / 623.67 | 2 | 3 |
5 | 13 | 856.88 | 25 | 13.40 | 1570 | 526 | 4.24 / 624.19 | 2 | 3 |
6 | 13 | 109.08 | 25 | 14.14 | 499 | 176 | 4.42 / 624.37 | 2 | 3 |
7 | 8 | 0.04 | 180 | 14.25 | 309 | 793 | 5.21 / 625.16 | 3 | 13 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 28 | 14.31 | 451 | 181 | 0.18 / 615.03 | 3 | 3 |
2 | 7 | 2002.72 | 52 | 10.35 | 3267 | 1758 | 1.94 / 616.79 | 3 | 3 |
3 | 13 | 1870.00 | 25 | 12.40 | 3114 | 965 | 2.90 / 617.76 | 2 | 3 |
4 | 13 | 1439.88 | 25 | 12.90 | 2443 | 788 | 3.69 / 618.54 | 2 | 3 |
5 | 13 | 717.76 | 25 | 13.50 | 1387 | 468 | 4.16 / 619.01 | 2 | 3 |
6 | 13 | 60.72 | 25 | 14.22 | 415 | 148 | 4.31 / 619.16 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.24 | 310 | 795 | 5.10 / 619.95 | 3 | 11 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 28 | 14.32 | 450 | 180 | 0.18 / 610.09 | 3 | 3 |
2 | 7 | 2004.92 | 52 | 10.40 | 3271 | 1769 | 1.95 / 611.86 | 3 | 3 |
3 | 13 | 1756.08 | 25 | 12.59 | 2927 | 921 | 2.87 / 612.78 | 2 | 3 |
4 | 13 | 1341.72 | 25 | 12.99 | 2254 | 732 | 3.60 / 613.52 | 2 | 3 |
5 | 13 | 627.44 | 25 | 13.61 | 1224 | 416 | 4.02 / 613.93 | 2 | 3 |
6 | 13 | 47.52 | 25 | 14.25 | 391 | 139 | 4.16 / 614.07 | 2 | 3 |
7 | 8 | -0.04 | 180 | 14.26 | 304 | 780 | 4.94 / 614.85 | 3 | 13 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 28 | 14.35 | 438 | 176 | 0.18 / 604.99 | 3 | 3 |
2 | 7 | 2002.44 | 53 | 10.48 | 3272 | 1817 | 1.99 / 606.81 | 2 | 3 |
3 | 13 | 1873.84 | 25 | 12.43 | 3123 | 970 | 2.96 / 607.78 | 2 | 3 |
4 | 13 | 1309.80 | 25 | 13.01 | 2226 | 724 | 3.69 / 608.51 | 2 | 3 |
5 | 13 | 738.56 | 25 | 13.51 | 1394 | 471 | 4.16 / 608.98 | 2 | 3 |
6 | 13 | 57.92 | 25 | 14.22 | 411 | 146 | 4.30 / 609.12 | 2 | 3 |
7 | 8 | 0.76 | 180 | 14.25 | 308 | 790 | 5.09 / 609.91 | 3 | 15 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 28 | 14.31 | 448 | 180 | 0.18 / 599.93 | 3 | 3 |
2 | 7 | 2003.36 | 52 | 10.46 | 3280 | 1784 | 1.96 / 601.71 | 3 | 3 |
3 | 13 | 1873.72 | 25 | 12.44 | 3116 | 969 | 2.93 / 602.68 | 2 | 3 |
4 | 13 | 1319.56 | 25 | 12.99 | 2260 | 734 | 3.67 / 603.42 | 2 | 3 |
5 | 13 | 732.12 | 25 | 13.49 | 1410 | 476 | 4.14 / 603.89 | 2 | 3 |
6 | 13 | 56.64 | 25 | 14.23 | 409 | 146 | 4.29 / 604.04 | 2 | 3 |
7 | 8 | -0.24 | 180 | 14.25 | 304 | 780 | 5.07 / 604.82 | 3 | 10 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 28 | 14.31 | 453 | 182 | 0.18 / 594.86 | 3 | 3 |
2 | 7 | 2003.80 | 53 | 10.47 | 3280 | 1820 | 2.00 / 596.68 | 3 | 3 |
3 | 13 | 1880.52 | 25 | 12.40 | 3135 | 972 | 2.97 / 597.65 | 2 | 3 |
4 | 13 | 1315.56 | 25 | 13.01 | 2248 | 731 | 3.70 / 598.38 | 2 | 3 |
5 | 13 | 725.68 | 25 | 13.54 | 1338 | 453 | 4.16 / 598.83 | 2 | 3 |
6 | 13 | 56.04 | 25 | 14.23 | 403 | 143 | 4.30 / 598.98 | 3 | 3 |
7 | 8 | -0.04 | 180 | 14.25 | 302 | 775 | 5.08 / 599.75 | 3 | 13 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 28 | 14.31 | 456 | 183 | 0.18 / 589.82 | 3 | 3 |
2 | 7 | 2004.40 | 52 | 10.51 | 3284 | 1795 | 1.98 / 591.62 | 2 | 3 |
3 | 13 | 1883.44 | 25 | 12.41 | 3119 | 968 | 2.95 / 592.59 | 2 | 3 |
4 | 13 | 1322.28 | 25 | 12.99 | 2261 | 734 | 3.68 / 593.32 | 2 | 3 |
5 | 13 | 614.72 | 25 | 13.63 | 1200 | 409 | 4.09 / 593.73 | 2 | 3 |
6 | 13 | 66.28 | 25 | 14.22 | 421 | 150 | 4.24 / 593.88 | 2 | 3 |
7 | 8 | 0.12 | 180 | 14.23 | 311 | 797 | 5.03 / 594.68 | 3 | 10 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 28 | 14.31 | 457 | 183 | 0.18 / 584.72 | 3 | 3 |
2 | 7 | 2003.12 | 52 | 10.53 | 3299 | 1806 | 1.99 / 586.53 | 3 | 3 |
3 | 13 | 1878.96 | 25 | 12.42 | 3122 | 969 | 2.96 / 587.50 | 2 | 3 |
4 | 13 | 1317.56 | 25 | 13.00 | 2264 | 736 | 3.69 / 588.23 | 2 | 3 |
5 | 13 | 741.32 | 25 | 13.51 | 1385 | 468 | 4.16 / 588.70 | 2 | 3 |
6 | 13 | 59.20 | 25 | 14.24 | 411 | 146 | 4.31 / 588.85 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.24 | 309 | 792 | 5.10 / 589.64 | 3 | 6 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 28 | 14.28 | 462 | 185 | 0.18 / 579.75 | 3 | 3 |
2 | 7 | 2006.76 | 53 | 10.61 | 3287 | 1848 | 2.03 / 581.60 | 2 | 3 |
3 | 13 | 1879.60 | 25 | 12.46 | 3128 | 974 | 3.01 / 582.57 | 2 | 3 |
4 | 13 | 1177.04 | 25 | 13.10 | 2067 | 677 | 3.68 / 583.25 | 2 | 3 |
5 | 13 | 487.36 | 25 | 13.73 | 1071 | 368 | 4.05 / 583.61 | 2 | 3 |
6 | 13 | 36.16 | 25 | 14.28 | 375 | 134 | 4.19 / 583.75 | 2 | 3 |
7 | 8 | 0.12 | 180 | 14.22 | 309 | 791 | 4.98 / 584.54 | 3 | 9 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 28 | 14.29 | 452 | 181 | 0.18 / 574.54 | 3 | 3 |
2 | 7 | 2001.96 | 52 | 10.59 | 3285 | 1809 | 1.99 / 576.35 | 2 | 3 |
3 | 13 | 1881.04 | 25 | 12.44 | 3128 | 973 | 2.96 / 577.32 | 2 | 3 |
4 | 13 | 1443.00 | 25 | 12.90 | 2456 | 792 | 3.75 / 578.11 | 2 | 3 |
5 | 13 | 832.48 | 25 | 13.43 | 1540 | 517 | 4.27 / 578.63 | 2 | 3 |
6 | 13 | 49.84 | 25 | 14.24 | 396 | 141 | 4.41 / 578.77 | 2 | 3 |
7 | 8 | -0.12 | 180 | 14.22 | 310 | 793 | 5.21 / 579.56 | 3 | 9 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 28 | 14.30 | 456 | 183 | 0.18 / 569.54 | 3 | 3 |
2 | 7 | 2002.00 | 52 | 10.62 | 3288 | 1816 | 2.00 / 571.35 | 3 | 3 |
3 | 13 | 1876.48 | 25 | 12.45 | 3121 | 971 | 2.97 / 572.33 | 2 | 3 |
4 | 13 | 1296.56 | 25 | 13.02 | 2235 | 727 | 3.70 / 573.05 | 2 | 3 |
5 | 13 | 565.44 | 25 | 13.68 | 1136 | 389 | 4.09 / 573.44 | 2 | 3 |
6 | 13 | 29.24 | 25 | 14.29 | 363 | 130 | 4.22 / 573.57 | 2 | 3 |
7 | 8 | 0.04 | 180 | 14.22 | 307 | 786 | 5.00 / 574.36 | 3 | 10 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 28 | 14.28 | 463 | 185 | 0.19 / 564.39 | 3 | 3 |
2 | 7 | 2008.72 | 52 | 10.61 | 3299 | 1820 | 2.01 / 566.21 | 3 | 3 |
3 | 13 | 1881.76 | 25 | 12.41 | 3134 | 972 | 2.98 / 567.18 | 2 | 3 |
4 | 13 | 1438.40 | 25 | 12.91 | 2446 | 789 | 3.77 / 567.97 | 2 | 3 |
5 | 13 | 696.24 | 25 | 13.55 | 1352 | 458 | 4.23 / 568.43 | 2 | 3 |
6 | 13 | 47.16 | 25 | 14.24 | 396 | 141 | 4.37 / 568.57 | 2 | 3 |
7 | 8 | 0.04 | 180 | 14.21 | 308 | 788 | 5.15 / 569.36 | 3 | 16 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 28 | 14.29 | 459 | 184 | 0.18 / 559.56 | 3 | 3 |
2 | 7 | 2001.04 | 53 | 10.66 | 3283 | 1855 | 2.04 / 561.41 | 3 | 3 |
3 | 13 | 1753.28 | 25 | 12.59 | 2919 | 919 | 2.96 / 562.33 | 2 | 3 |
4 | 13 | 1190.28 | 25 | 13.13 | 2039 | 669 | 3.63 / 563.00 | 2 | 3 |
5 | 13 | 600.60 | 25 | 13.65 | 1198 | 409 | 4.04 / 563.41 | 2 | 3 |
6 | 8 | 0.12 | 180 | 14.22 | 310 | 793 | 4.83 / 564.20 | 3 | 8 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 27 | 14.26 | 467 | 180 | 0.18 / 554.44 | 3 | 3 |
2 | 7 | 2006.28 | 52 | 10.70 | 3298 | 1835 | 2.01 / 556.27 | 2 | 3 |
3 | 13 | 1891.08 | 25 | 12.43 | 3135 | 974 | 2.99 / 557.24 | 2 | 3 |
4 | 13 | 1333.48 | 25 | 13.00 | 2279 | 741 | 3.73 / 557.99 | 2 | 3 |
5 | 13 | 750.36 | 25 | 13.49 | 1430 | 482 | 4.21 / 558.47 | 2 | 3 |
6 | 13 | 1.44 | 25 | 14.35 | 318 | 114 | 4.33 / 558.58 | 2 | 3 |
7 | 8 | 0.20 | 180 | 14.17 | 310 | 791 | 5.12 / 559.37 | 3 | 13 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 27 | 14.26 | 470 | 181 | 0.18 / 549.55 | 3 | 3 |
2 | 7 | 2004.28 | 53 | 10.68 | 3289 | 1862 | 2.04 / 551.42 | 3 | 3 |
3 | 13 | 1875.44 | 25 | 12.43 | 3111 | 967 | 3.01 / 552.38 | 2 | 3 |
4 | 13 | 1163.92 | 25 | 13.14 | 2025 | 665 | 3.67 / 553.05 | 2 | 3 |
5 | 13 | 599.92 | 25 | 13.64 | 1203 | 410 | 4.08 / 553.46 | 2 | 3 |
6 | 8 | -0.12 | 180 | 14.20 | 312 | 797 | 4.88 / 554.26 | 3 | 7 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 27 | 14.27 | 466 | 180 | 0.18 / 544.68 | 3 | 3 |
2 | 7 | 2003.44 | 52 | 10.73 | 3281 | 1831 | 2.01 / 546.51 | 3 | 3 |
3 | 13 | 1744.80 | 25 | 12.59 | 2919 | 919 | 2.93 / 547.43 | 2 | 3 |
4 | 13 | 1191.32 | 25 | 13.11 | 2063 | 676 | 3.61 / 548.10 | 2 | 3 |
5 | 13 | 488.36 | 25 | 13.75 | 1031 | 354 | 3.96 / 548.46 | 2 | 3 |
6 | 13 | 18.28 | 25 | 14.30 | 350 | 125 | 4.08 / 548.58 | 2 | 3 |
7 | 8 | 0.12 | 180 | 14.16 | 311 | 793 | 4.88 / 549.37 | 3 | 13 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 27 | 14.27 | 469 | 181 | 0.18 / 539.69 | 3 | 3 |
2 | 7 | 2002.96 | 52 | 10.82 | 3275 | 1843 | 2.02 / 541.53 | 2 | 3 |
3 | 13 | 1881.16 | 25 | 12.41 | 3130 | 971 | 2.99 / 542.50 | 2 | 3 |
4 | 13 | 1308.44 | 25 | 13.01 | 2242 | 729 | 3.72 / 543.23 | 2 | 3 |
5 | 13 | 744.12 | 25 | 13.51 | 1405 | 475 | 4.20 / 543.70 | 2 | 3 |
6 | 8 | -0.20 | 180 | 14.21 | 310 | 793 | 4.99 / 544.50 | 3 | 10 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 27 | 14.29 | 468 | 181 | 0.18 / 534.70 | 3 | 3 |
2 | 7 | 2006.76 | 53 | 10.73 | 3303 | 1878 | 2.06 / 536.57 | 3 | 3 |
3 | 13 | 1883.08 | 25 | 12.43 | 3134 | 974 | 3.03 / 537.55 | 2 | 3 |
4 | 13 | 1296.16 | 25 | 13.04 | 2210 | 720 | 3.75 / 538.27 | 2 | 3 |
5 | 13 | 699.44 | 25 | 13.56 | 1316 | 446 | 4.20 / 538.71 | 2 | 3 |
6 | 8 | 0.36 | 180 | 14.21 | 309 | 790 | 4.99 / 539.51 | 2 | 12 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 26 | 14.31 | 466 | 173 | 0.17 / 529.61 | 3 | 3 |
2 | 3 | 1029.60 | 1 | 12.23 | 1911 | 23 | 0.20 / 529.63 | 2 | 3 |
3 | 7 | 2006.68 | 52 | 10.87 | 3294 | 1862 | 2.06 / 531.50 | 2 | 3 |
4 | 13 | 1889.12 | 25 | 12.45 | 3143 | 978 | 3.04 / 532.47 | 2 | 3 |
5 | 13 | 1304.16 | 25 | 13.03 | 2243 | 731 | 3.77 / 533.20 | 2 | 3 |
6 | 13 | 586.12 | 25 | 13.66 | 1174 | 401 | 4.17 / 533.60 | 2 | 3 |
7 | 13 | 14.04 | 25 | 14.31 | 339 | 121 | 4.29 / 533.73 | 2 | 3 |
8 | 8 | -0.32 | 180 | 14.19 | 309 | 789 | 5.08 / 534.52 | 3 | 19 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 28 | 14.30 | 465 | 186 | 0.19 / 524.61 | 3 | 3 |
2 | 3 | 972.76 | -1 | 14.30 | 465 | 0 | 0.00 / 524.61 | 3 | 3 |
3 | 7 | 2004.56 | 53 | 10.82 | 3296 | 1890 | 2.08 / 526.50 | 3 | 3 |
4 | 13 | 1871.48 | 25 | 12.47 | 3100 | 966 | 3.04 / 527.47 | 2 | 3 |
5 | 13 | 1281.28 | 25 | 13.05 | 2205 | 719 | 3.76 / 528.19 | 2 | 3 |
6 | 13 | 693.16 | 25 | 13.55 | 1344 | 455 | 4.22 / 528.64 | 2 | 3 |
7 | 8 | 0.24 | 180 | 14.21 | 311 | 795 | 5.01 / 529.44 | 3 | 8 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 27 | 14.29 | 469 | 181 | 0.18 / 519.54 | 3 | 3 |
2 | 7 | 2005.84 | 52 | 10.85 | 3301 | 1862 | 2.04 / 521.40 | 2 | 3 |
3 | 13 | 1874.44 | 25 | 12.47 | 3117 | 972 | 3.02 / 522.37 | 2 | 3 |
4 | 13 | 1297.16 | 25 | 13.05 | 2229 | 727 | 3.74 / 523.10 | 2 | 3 |
5 | 13 | 573.92 | 25 | 13.66 | 1189 | 406 | 4.15 / 523.51 | 2 | 3 |
6 | 13 | 9.24 | 25 | 14.30 | 333 | 119 | 4.27 / 523.63 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.18 | 312 | 796 | 5.06 / 524.42 | 3 | 9 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 27 | 14.30 | 466 | 180 | 0.18 / 514.64 | 3 | 3 |
2 | 7 | 2005.36 | 52 | 10.86 | 3283 | 1854 | 2.03 / 516.50 | 3 | 3 |
3 | 13 | 1751.76 | 25 | 12.58 | 2930 | 921 | 2.96 / 517.42 | 2 | 3 |
4 | 13 | 1334.04 | 25 | 13.03 | 2260 | 736 | 3.69 / 518.15 | 2 | 3 |
5 | 13 | 603.16 | 25 | 13.63 | 1227 | 418 | 4.11 / 518.57 | 2 | 3 |
6 | 8 | 0.08 | 180 | 14.21 | 308 | 788 | 4.90 / 519.36 | 3 | 13 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 28 | 14.29 | 459 | 184 | 0.18 / 509.60 | 3 | 3 |
2 | 3 | 965.28 | -1 | 14.29 | 459 | 0 | 0.00 / 509.60 | 3 | 3 |
3 | 3 | 1033.16 | 1 | 12.12 | 1898 | 23 | 0.21 / 509.62 | 2 | 3 |
4 | 7 | 2004.88 | 52 | 10.90 | 3293 | 1866 | 2.07 / 511.49 | 3 | 3 |
5 | 13 | 1877.76 | 25 | 12.48 | 3122 | 974 | 3.05 / 512.46 | 2 | 3 |
6 | 13 | 1182.24 | 25 | 13.13 | 2059 | 676 | 3.72 / 513.14 | 2 | 3 |
7 | 13 | 618.24 | 25 | 13.63 | 1224 | 417 | 4.14 / 513.55 | 2 | 3 |
8 | 13 | 13.12 | 25 | 14.31 | 337 | 121 | 4.26 / 513.67 | 3 | 3 |
9 | 8 | -0.04 | 180 | 14.18 | 309 | 789 | 5.05 / 514.46 | 3 | 7 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 28 | 14.29 | 479 | 192 | 0.19 / 504.67 | 3 | 3 |
2 | 3 | 971.36 | -1 | 14.29 | 479 | 0 | 0.00 / 504.67 | 3 | 3 |
3 | 3 | 1044.16 | 1 | 12.34 | 1907 | 24 | 0.22 / 504.69 | 2 | 3 |
4 | 7 | 2005.84 | 52 | 10.93 | 3286 | 1868 | 2.08 / 506.56 | 3 | 3 |
5 | 13 | 1879.48 | 25 | 12.49 | 3120 | 974 | 3.06 / 507.54 | 2 | 3 |
6 | 13 | 1183.52 | 25 | 13.13 | 2062 | 677 | 3.73 / 508.21 | 2 | 3 |
7 | 13 | 607.20 | 25 | 13.66 | 1206 | 412 | 4.15 / 508.63 | 2 | 3 |
8 | 8 | 0.00 | 180 | 14.21 | 308 | 788 | 4.93 / 509.41 | 3 | 13 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 28 | 14.29 | 467 | 187 | 0.19 / 499.59 | 3 | 3 |
2 | 7 | 2004.52 | 52 | 10.91 | 3283 | 1863 | 2.05 / 501.45 | 3 | 3 |
3 | 13 | 1885.32 | 25 | 12.46 | 3137 | 977 | 3.03 / 502.43 | 2 | 3 |
4 | 13 | 1322.88 | 25 | 13.03 | 2249 | 733 | 3.76 / 503.16 | 2 | 3 |
5 | 13 | 605.48 | 25 | 13.67 | 1184 | 405 | 4.16 / 503.57 | 2 | 3 |
6 | 13 | 18.80 | 25 | 14.30 | 345 | 123 | 4.29 / 503.69 | 2 | 3 |
7 | 8 | 0.12 | 180 | 14.20 | 309 | 790 | 5.08 / 504.48 | 3 | 12 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 28 | 14.32 | 459 | 184 | 0.18 / 494.49 | 3 | 3 |
2 | 3 | 973.28 | -1 | 14.32 | 459 | 0 | 0.00 / 494.49 | 3 | 3 |
3 | 3 | 1046.28 | 1 | 12.47 | 1920 | 24 | 0.21 / 494.51 | 2 | 3 |
4 | 7 | 2001.16 | 53 | 10.98 | 3281 | 1909 | 2.12 / 496.42 | 3 | 3 |
5 | 13 | 1870.92 | 25 | 12.49 | 3108 | 970 | 3.09 / 497.39 | 2 | 3 |
6 | 13 | 1290.48 | 25 | 13.06 | 2200 | 718 | 3.81 / 498.11 | 2 | 3 |
7 | 13 | 558.28 | 25 | 13.70 | 1129 | 387 | 4.19 / 498.50 | 2 | 3 |
8 | 13 | 7.96 | 25 | 14.32 | 329 | 118 | 4.31 / 498.62 | 2 | 3 |
9 | 8 | 0.08 | 180 | 14.18 | 308 | 786 | 5.10 / 499.40 | 3 | 7 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 28 | 14.32 | 458 | 184 | 0.18 / 489.38 | 3 | 3 |
2 | 7 | 2003.72 | 53 | 10.94 | 3285 | 1905 | 2.09 / 491.28 | 3 | 3 |
3 | 13 | 1877.04 | 25 | 12.47 | 3129 | 975 | 3.06 / 492.26 | 2 | 3 |
4 | 13 | 1296.92 | 25 | 13.04 | 2221 | 724 | 3.79 / 492.98 | 2 | 3 |
5 | 13 | 567.08 | 25 | 13.68 | 1176 | 402 | 4.19 / 493.38 | 2 | 3 |
6 | 13 | 27.08 | 25 | 14.30 | 363 | 130 | 4.32 / 493.51 | 2 | 3 |
7 | 8 | -0.16 | 180 | 14.20 | 310 | 792 | 5.11 / 494.31 | 3 | 5 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 28 | 14.33 | 462 | 185 | 0.19 / 484.53 | 3 | 3 |
2 | 7 | 2002.04 | 52 | 10.95 | 3278 | 1866 | 2.05 / 486.39 | 3 | 3 |
3 | 13 | 1875.72 | 25 | 12.47 | 3128 | 975 | 3.03 / 487.37 | 2 | 3 |
4 | 13 | 1179.96 | 25 | 13.13 | 2066 | 678 | 3.71 / 488.05 | 2 | 3 |
5 | 13 | 467.60 | 25 | 13.77 | 1018 | 350 | 4.06 / 488.40 | 2 | 3 |
6 | 8 | 0.12 | 180 | 14.21 | 311 | 795 | 4.85 / 489.19 | 3 | 10 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 28 | 14.32 | 469 | 188 | 0.19 / 479.47 | 3 | 3 |
2 | 7 | 2001.64 | 53 | 10.95 | 3274 | 1900 | 2.09 / 481.37 | 3 | 3 |
3 | 13 | 1745.08 | 25 | 12.64 | 2915 | 921 | 3.01 / 482.29 | 2 | 3 |
4 | 13 | 1328.68 | 25 | 13.05 | 2239 | 730 | 3.74 / 483.02 | 2 | 3 |
5 | 13 | 595.92 | 25 | 13.67 | 1169 | 400 | 4.14 / 483.42 | 2 | 3 |
6 | 13 | 26.64 | 25 | 14.29 | 359 | 128 | 4.27 / 483.55 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.20 | 310 | 792 | 5.06 / 484.34 | 3 | 6 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 28 | 14.34 | 455 | 183 | 0.18 / 474.55 | 3 | 3 |
2 | 7 | 2005.76 | 52 | 10.96 | 3287 | 1873 | 2.06 / 476.43 | 3 | 3 |
3 | 13 | 1745.68 | 25 | 12.63 | 2923 | 923 | 2.98 / 477.35 | 2 | 3 |
4 | 13 | 1318.88 | 25 | 13.04 | 2244 | 732 | 3.71 / 478.08 | 2 | 3 |
5 | 13 | 594.20 | 25 | 13.65 | 1209 | 413 | 4.12 / 478.49 | 2 | 3 |
6 | 8 | 0.00 | 180 | 14.21 | 309 | 790 | 4.91 / 479.28 | 3 | 13 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 28 | 14.37 | 451 | 181 | 0.18 / 469.47 | 3 | 3 |
2 | 7 | 2005.28 | 52 | 11.00 | 3278 | 1875 | 2.06 / 471.35 | 3 | 3 |
3 | 13 | 1880.80 | 25 | 12.48 | 3141 | 980 | 3.04 / 472.33 | 2 | 3 |
4 | 13 | 1289.92 | 25 | 13.07 | 2209 | 722 | 3.76 / 473.05 | 2 | 3 |
5 | 13 | 572.72 | 25 | 13.68 | 1173 | 401 | 4.16 / 473.45 | 2 | 3 |
6 | 13 | 26.52 | 25 | 14.30 | 358 | 128 | 4.29 / 473.58 | 2 | 3 |
7 | 8 | 0.20 | 180 | 14.20 | 309 | 790 | 5.08 / 474.37 | 3 | 4 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 28 | 14.39 | 454 | 183 | 0.18 / 464.45 | 3 | 3 |
2 | 7 | 2003.16 | 52 | 11.01 | 3267 | 1870 | 2.05 / 466.32 | 3 | 3 |
3 | 13 | 1874.48 | 25 | 12.47 | 3115 | 971 | 3.02 / 467.29 | 2 | 3 |
4 | 13 | 1184.84 | 25 | 13.14 | 2075 | 682 | 3.71 / 467.97 | 2 | 3 |
5 | 13 | 605.24 | 25 | 13.67 | 1204 | 411 | 4.12 / 468.38 | 2 | 3 |
6 | 13 | 30.48 | 25 | 14.30 | 359 | 128 | 4.25 / 468.51 | 2 | 3 |
7 | 8 | -0.24 | 180 | 14.21 | 306 | 783 | 5.03 / 469.29 | 3 | 6 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 28 | 14.39 | 450 | 181 | 0.18 / 459.48 | 3 | 3 |
2 | 7 | 2007.80 | 53 | 11.03 | 3276 | 1915 | 2.10 / 461.40 | 3 | 3 |
3 | 13 | 1742.80 | 25 | 12.66 | 2912 | 922 | 3.02 / 462.32 | 2 | 3 |
4 | 13 | 1198.56 | 25 | 13.16 | 2054 | 676 | 3.69 / 463.00 | 2 | 3 |
5 | 13 | 474.68 | 25 | 13.79 | 1022 | 352 | 4.05 / 463.35 | 2 | 3 |
6 | 13 | 34.24 | 25 | 14.30 | 366 | 131 | 4.18 / 463.48 | 3 | 3 |
7 | 8 | -0.04 | 180 | 14.21 | 306 | 783 | 4.96 / 464.26 | 3 | 7 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 28 | 14.37 | 445 | 179 | 0.18 / 454.34 | 3 | 3 |
2 | 7 | 2003.88 | 52 | 11.02 | 3269 | 1873 | 2.05 / 456.21 | 3 | 3 |
3 | 13 | 1872.48 | 25 | 12.49 | 3127 | 976 | 3.03 / 457.19 | 2 | 3 |
4 | 13 | 1305.20 | 25 | 13.05 | 2238 | 730 | 3.76 / 457.92 | 2 | 3 |
5 | 13 | 702.36 | 25 | 13.59 | 1354 | 460 | 4.22 / 458.38 | 2 | 3 |
6 | 13 | 51.12 | 25 | 14.27 | 395 | 141 | 4.36 / 458.52 | 2 | 3 |
7 | 8 | -0.16 | 180 | 14.21 | 306 | 783 | 5.14 / 459.30 | 3 | 16 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 28 | 14.37 | 455 | 183 | 0.18 / 449.40 | 3 | 3 |
2 | 7 | 2004.92 | 52 | 11.07 | 3269 | 1882 | 2.06 / 451.28 | 2 | 3 |
3 | 13 | 1740.48 | 25 | 12.68 | 2909 | 922 | 2.99 / 452.20 | 2 | 3 |
4 | 13 | 1192.20 | 25 | 13.15 | 2074 | 682 | 3.67 / 452.88 | 2 | 3 |
5 | 13 | 475.60 | 25 | 13.78 | 1041 | 359 | 4.03 / 453.24 | 2 | 3 |
6 | 13 | 35.48 | 25 | 14.30 | 371 | 133 | 4.16 / 453.37 | 3 | 3 |
7 | 8 | -0.12 | 180 | 14.20 | 308 | 787 | 4.95 / 454.16 | 3 | 6 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 28 | 14.40 | 445 | 179 | 0.18 / 444.43 | 3 | 3 |
2 | 7 | 2005.28 | 53 | 11.10 | 3277 | 1928 | 2.11 / 446.36 | 2 | 3 |
3 | 13 | 1747.84 | 25 | 12.67 | 2924 | 926 | 3.03 / 447.28 | 2 | 3 |
4 | 13 | 1194.36 | 25 | 13.17 | 2042 | 672 | 3.71 / 447.95 | 2 | 3 |
5 | 13 | 482.48 | 25 | 13.81 | 1007 | 348 | 4.05 / 448.30 | 2 | 3 |
6 | 13 | 35.20 | 25 | 14.30 | 369 | 132 | 4.19 / 448.43 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.21 | 305 | 780 | 4.97 / 449.21 | 3 | 7 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 28 | 14.38 | 453 | 182 | 0.18 / 439.34 | 3 | 3 |
2 | 7 | 2002.88 | 52 | 11.11 | 3273 | 1891 | 2.07 / 441.23 | 2 | 3 |
3 | 13 | 1875.68 | 25 | 12.54 | 3128 | 981 | 3.05 / 442.21 | 2 | 3 |
4 | 13 | 1296.24 | 25 | 13.08 | 2231 | 730 | 3.78 / 442.94 | 2 | 3 |
5 | 13 | 569.84 | 25 | 13.70 | 1153 | 395 | 4.18 / 443.34 | 2 | 3 |
6 | 13 | 24.40 | 25 | 14.31 | 356 | 127 | 4.31 / 443.46 | 3 | 3 |
7 | 8 | -0.08 | 180 | 14.21 | 307 | 785 | 5.09 / 444.25 | 3 | 7 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 28 | 14.41 | 443 | 179 | 0.18 / 434.30 | 3 | 3 |
2 | 7 | 2002.52 | 52 | 11.07 | 3267 | 1881 | 2.06 / 436.18 | 3 | 3 |
3 | 13 | 1874.16 | 25 | 12.54 | 3123 | 979 | 3.04 / 437.16 | 2 | 3 |
4 | 13 | 1166.20 | 25 | 13.17 | 2048 | 674 | 3.71 / 437.83 | 2 | 3 |
5 | 13 | 590.40 | 25 | 13.68 | 1211 | 414 | 4.13 / 438.24 | 2 | 3 |
6 | 13 | 32.08 | 25 | 14.30 | 367 | 131 | 4.26 / 438.38 | 2 | 3 |
7 | 8 | 0.20 | 180 | 14.20 | 306 | 782 | 5.04 / 439.16 | 3 | 3 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 28 | 14.37 | 446 | 179 | 0.18 / 429.38 | 3 | 3 |
2 | 7 | 2003.36 | 52 | 11.10 | 3268 | 1886 | 2.07 / 431.27 | 3 | 3 |
3 | 13 | 1742.20 | 25 | 12.68 | 2902 | 920 | 2.99 / 432.19 | 2 | 3 |
4 | 13 | 1174.08 | 25 | 13.17 | 2028 | 668 | 3.65 / 432.85 | 2 | 3 |
5 | 13 | 458.88 | 25 | 13.82 | 994 | 343 | 4.00 / 433.20 | 2 | 3 |
6 | 13 | 32.12 | 25 | 14.31 | 370 | 132 | 4.13 / 433.33 | 2 | 3 |
7 | 8 | -0.20 | 180 | 14.20 | 308 | 787 | 4.92 / 434.12 | 3 | 9 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 28 | 14.38 | 441 | 178 | 0.18 / 424.27 | 3 | 3 |
2 | 7 | 2004.92 | 52 | 11.09 | 3271 | 1886 | 2.06 / 426.15 | 3 | 3 |
3 | 13 | 1884.76 | 25 | 12.55 | 3130 | 982 | 3.05 / 427.13 | 2 | 3 |
4 | 13 | 1182.72 | 25 | 13.18 | 2042 | 673 | 3.72 / 427.81 | 2 | 3 |
5 | 13 | 744.52 | 25 | 13.56 | 1436 | 487 | 4.21 / 428.29 | 2 | 3 |
6 | 13 | 26.32 | 25 | 14.32 | 355 | 127 | 4.33 / 428.42 | 3 | 3 |
7 | 8 | -0.20 | 180 | 14.20 | 305 | 780 | 5.11 / 429.20 | 3 | 9 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 28 | 14.40 | 442 | 178 | 0.18 / 419.36 | 3 | 3 |
2 | 7 | 2003.08 | 52 | 11.09 | 3261 | 1881 | 2.06 / 421.24 | 3 | 3 |
3 | 13 | 1747.12 | 25 | 12.69 | 2915 | 925 | 2.98 / 422.16 | 2 | 3 |
4 | 13 | 1195.60 | 25 | 13.19 | 2043 | 674 | 3.66 / 422.84 | 2 | 3 |
5 | 13 | 482.96 | 25 | 13.81 | 1020 | 352 | 4.01 / 423.19 | 2 | 3 |
6 | 13 | 17.92 | 25 | 14.33 | 343 | 123 | 4.13 / 423.31 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.16 | 305 | 777 | 4.91 / 424.09 | 3 | 4 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 28 | 14.39 | 450 | 181 | 0.18 / 414.22 | 3 | 3 |
2 | 7 | 2003.08 | 52 | 11.09 | 3260 | 1880 | 2.06 / 416.10 | 3 | 3 |
3 | 13 | 1876.76 | 25 | 12.55 | 3123 | 980 | 3.04 / 417.08 | 2 | 3 |
4 | 13 | 1303.00 | 25 | 13.08 | 2235 | 731 | 3.77 / 417.81 | 2 | 3 |
5 | 13 | 712.80 | 25 | 13.61 | 1351 | 460 | 4.23 / 418.27 | 2 | 3 |
6 | 13 | 27.24 | 25 | 14.32 | 358 | 128 | 4.36 / 418.40 | 2 | 3 |
7 | 8 | 0.28 | 180 | 14.20 | 306 | 782 | 5.14 / 419.18 | 3 | 6 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 28 | 14.40 | 449 | 181 | 0.18 / 409.19 | 3 | 3 |
2 | 7 | 2002.92 | 52 | 11.08 | 3268 | 1883 | 2.06 / 411.08 | 3 | 3 |
3 | 13 | 1746.32 | 25 | 12.70 | 2927 | 929 | 2.99 / 412.00 | 2 | 3 |
4 | 13 | 1209.32 | 25 | 13.19 | 2076 | 685 | 3.68 / 412.69 | 2 | 3 |
5 | 13 | 635.76 | 25 | 13.65 | 1271 | 434 | 4.11 / 413.12 | 2 | 3 |
6 | 13 | 30.16 | 25 | 14.31 | 362 | 130 | 4.24 / 413.25 | 2 | 3 |
7 | 8 | -0.44 | 180 | 14.19 | 307 | 784 | 5.03 / 414.04 | 3 | 5 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 27 | 14.39 | 457 | 178 | 0.18 / 404.17 | 3 | 3 |
2 | 7 | 2003.08 | 53 | 11.15 | 3260 | 1926 | 2.10 / 406.10 | 2 | 3 |
3 | 13 | 1752.76 | 25 | 12.72 | 2918 | 928 | 3.03 / 407.03 | 2 | 3 |
4 | 13 | 1318.88 | 25 | 13.13 | 2242 | 736 | 3.77 / 407.76 | 2 | 3 |
5 | 13 | 433.96 | 25 | 13.86 | 975 | 338 | 4.11 / 408.10 | 2 | 3 |
6 | 13 | 24.72 | 25 | 14.33 | 355 | 127 | 4.23 / 408.23 | 2 | 3 |
7 | 8 | 0.12 | 180 | 14.20 | 307 | 785 | 5.02 / 409.01 | 3 | 7 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 27 | 14.41 | 457 | 178 | 0.18 / 399.32 | 3 | 3 |
2 | 7 | 2003.84 | 53 | 11.04 | 3258 | 1906 | 2.08 / 401.22 | 3 | 3 |
3 | 13 | 1872.92 | 25 | 12.61 | 3108 | 980 | 3.06 / 402.20 | 2 | 3 |
4 | 13 | 1153.32 | 25 | 13.21 | 2032 | 671 | 3.73 / 402.87 | 2 | 3 |
5 | 13 | 429.72 | 25 | 13.86 | 960 | 333 | 4.07 / 403.21 | 2 | 3 |
6 | 8 | -0.08 | 180 | 14.21 | 308 | 788 | 4.86 / 403.99 | 3 | 9 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 27 | 14.38 | 463 | 180 | 0.18 / 394.24 | 3 | 3 |
2 | 7 | 2004.48 | 52 | 10.97 | 3276 | 1869 | 2.05 / 396.11 | 3 | 3 |
3 | 13 | 1878.68 | 25 | 12.59 | 3119 | 982 | 3.03 / 397.09 | 2 | 3 |
4 | 13 | 1294.28 | 25 | 13.12 | 2230 | 731 | 3.76 / 397.82 | 2 | 3 |
5 | 13 | 564.48 | 25 | 13.74 | 1158 | 398 | 4.16 / 398.22 | 2 | 3 |
6 | 13 | 23.48 | 25 | 14.33 | 355 | 127 | 4.29 / 398.35 | 2 | 3 |
7 | 8 | 0.04 | 180 | 14.19 | 310 | 792 | 5.08 / 399.14 | 3 | 4 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 27 | 14.39 | 458 | 178 | 0.18 / 389.25 | 3 | 3 |
2 | 7 | 2004.84 | 53 | 10.95 | 3270 | 1898 | 2.08 / 391.15 | 3 | 3 |
3 | 13 | 1748.08 | 25 | 12.74 | 2918 | 929 | 3.01 / 392.08 | 2 | 3 |
4 | 13 | 1314.64 | 25 | 13.15 | 2224 | 731 | 3.74 / 392.81 | 2 | 3 |
5 | 13 | 440.16 | 25 | 13.87 | 968 | 336 | 4.07 / 393.14 | 2 | 3 |
6 | 13 | 28.76 | 25 | 14.34 | 362 | 130 | 4.20 / 393.27 | 2 | 3 |
7 | 8 | -0.12 | 180 | 14.19 | 308 | 787 | 4.99 / 394.06 | 3 | 7 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 27 | 14.38 | 466 | 181 | 0.18 / 384.29 | 3 | 3 |
2 | 7 | 2007.72 | 52 | 11.02 | 3263 | 1870 | 2.05 / 386.16 | 3 | 3 |
3 | 13 | 1875.32 | 25 | 12.61 | 3118 | 983 | 3.03 / 387.15 | 2 | 3 |
4 | 13 | 1290.84 | 25 | 13.16 | 2210 | 727 | 3.76 / 387.87 | 2 | 3 |
5 | 13 | 571.24 | 25 | 13.75 | 1177 | 405 | 4.17 / 388.28 | 2 | 3 |
6 | 8 | 0.12 | 180 | 14.22 | 310 | 793 | 4.96 / 389.07 | 3 | 12 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 27 | 14.36 | 480 | 186 | 0.19 / 379.40 | 3 | 3 |
2 | 7 | 2004.60 | 52 | 10.96 | 3262 | 1859 | 2.05 / 381.26 | 3 | 3 |
3 | 13 | 1879.52 | 25 | 12.59 | 3120 | 982 | 3.03 / 382.24 | 2 | 3 |
4 | 13 | 1176.08 | 25 | 13.26 | 2028 | 672 | 3.70 / 382.91 | 2 | 3 |
5 | 13 | 591.12 | 25 | 13.74 | 1188 | 408 | 4.11 / 383.32 | 2 | 3 |
6 | 8 | -0.04 | 180 | 14.22 | 310 | 793 | 4.90 / 384.11 | 3 | 15 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 27 | 14.38 | 469 | 182 | 0.18 / 374.50 | 3 | 3 |
2 | 7 | 2006.52 | 52 | 10.92 | 3263 | 1853 | 2.03 / 376.35 | 2 | 3 |
3 | 13 | 1880.52 | 25 | 12.61 | 3133 | 988 | 3.02 / 377.34 | 2 | 3 |
4 | 13 | 1308.12 | 25 | 13.15 | 2238 | 736 | 3.76 / 378.07 | 2 | 3 |
5 | 13 | 444.68 | 25 | 13.87 | 989 | 343 | 4.10 / 378.42 | 2 | 3 |
6 | 8 | -0.04 | 180 | 14.22 | 311 | 796 | 4.90 / 379.21 | 3 | 7 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 27 | 14.40 | 465 | 181 | 0.18 / 369.49 | 3 | 3 |
2 | 7 | 2001.40 | 52 | 10.92 | 3249 | 1845 | 2.03 / 371.33 | 3 | 3 |
3 | 13 | 1872.56 | 25 | 12.65 | 3103 | 981 | 3.01 / 372.32 | 2 | 3 |
4 | 13 | 1309.24 | 25 | 13.16 | 2228 | 733 | 3.74 / 373.05 | 2 | 3 |
5 | 13 | 720.68 | 25 | 13.64 | 1393 | 475 | 4.22 / 373.52 | 2 | 3 |
6 | 8 | -0.08 | 180 | 14.22 | 309 | 791 | 5.01 / 374.31 | 2 | 13 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 27 | 14.41 | 456 | 177 | 0.18 / 364.54 | 3 | 3 |
2 | 7 | 2003.00 | 53 | 10.86 | 3254 | 1873 | 2.05 / 366.41 | 3 | 3 |
3 | 13 | 1872.08 | 25 | 12.63 | 3114 | 983 | 3.03 / 367.40 | 2 | 3 |
4 | 13 | 1299.36 | 25 | 13.19 | 2214 | 730 | 3.76 / 368.13 | 2 | 3 |
5 | 13 | 574.44 | 25 | 13.78 | 1139 | 392 | 4.16 / 368.52 | 2 | 3 |
6 | 8 | 0.16 | 180 | 14.22 | 309 | 791 | 4.95 / 369.31 | 3 | 11 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 27 | 14.38 | 470 | 182 | 0.18 / 359.64 | 3 | 3 |
2 | 7 | 2002.12 | 52 | 10.86 | 3251 | 1836 | 2.02 / 361.48 | 3 | 3 |
3 | 13 | 1746.24 | 25 | 12.81 | 2909 | 932 | 2.95 / 362.41 | 2 | 3 |
4 | 13 | 1193.48 | 25 | 13.30 | 2035 | 677 | 3.63 / 363.09 | 2 | 3 |
5 | 13 | 480.36 | 25 | 13.86 | 1049 | 363 | 3.99 / 363.45 | 2 | 3 |
6 | 13 | 15.80 | 25 | 14.37 | 339 | 122 | 4.11 / 363.57 | 3 | 3 |
7 | 8 | -0.04 | 180 | 14.16 | 309 | 788 | 4.90 / 364.36 | 3 | 4 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 27 | 14.40 | 468 | 182 | 0.18 / 354.68 | 3 | 3 |
2 | 7 | 2002.04 | 52 | 10.88 | 3259 | 1844 | 2.03 / 356.52 | 2 | 3 |
3 | 13 | 1872.88 | 25 | 12.65 | 3106 | 982 | 3.01 / 357.50 | 2 | 3 |
4 | 13 | 1281.08 | 25 | 13.20 | 2180 | 719 | 3.73 / 358.22 | 2 | 3 |
5 | 13 | 676.88 | 25 | 13.69 | 1310 | 448 | 4.18 / 358.67 | 2 | 3 |
6 | 8 | 0.24 | 180 | 14.21 | 310 | 793 | 4.97 / 359.46 | 3 | 6 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 27 | 14.40 | 469 | 182 | 0.18 / 349.73 | 3 | 3 |
2 | 7 | 2007.60 | 52 | 10.90 | 3274 | 1856 | 2.04 / 351.58 | 3 | 3 |
3 | 13 | 1885.32 | 25 | 12.66 | 3121 | 988 | 3.03 / 352.57 | 2 | 3 |
4 | 13 | 1295.04 | 25 | 13.21 | 2211 | 730 | 3.76 / 353.30 | 2 | 3 |
5 | 13 | 570.36 | 25 | 13.79 | 1155 | 398 | 4.15 / 353.70 | 2 | 3 |
6 | 8 | -0.04 | 180 | 14.22 | 310 | 793 | 4.95 / 354.49 | 2 | 7 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 27 | 14.43 | 470 | 183 | 0.18 / 344.81 | 3 | 3 |
2 | 7 | 2002.00 | 52 | 11.04 | 3261 | 1872 | 2.06 / 346.68 | 2 | 3 |
3 | 13 | 1871.84 | 25 | 12.70 | 3091 | 981 | 3.04 / 347.66 | 2 | 3 |
4 | 13 | 1177.40 | 25 | 13.30 | 2029 | 675 | 3.71 / 348.33 | 2 | 3 |
5 | 13 | 606.80 | 25 | 13.79 | 1193 | 411 | 4.12 / 348.74 | 2 | 3 |
6 | 8 | 0.08 | 180 | 14.22 | 313 | 801 | 4.92 / 349.55 | 3 | 11 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 26 | 14.44 | 469 | 176 | 0.18 / 339.92 | 3 | 3 |
2 | 3 | 1025.48 | 1 | 12.74 | 1915 | 24 | 0.20 / 339.95 | 2 | 3 |
3 | 7 | 2004.56 | 52 | 11.04 | 3265 | 1874 | 2.07 / 341.82 | 2 | 3 |
4 | 13 | 1872.76 | 25 | 12.68 | 3109 | 986 | 3.06 / 342.81 | 2 | 3 |
5 | 13 | 1161.12 | 25 | 13.32 | 2013 | 670 | 3.73 / 343.48 | 2 | 3 |
6 | 13 | 454.64 | 25 | 13.91 | 1009 | 351 | 4.08 / 343.83 | 2 | 3 |
7 | 8 | -0.12 | 180 | 14.23 | 310 | 794 | 4.88 / 344.62 | 3 | 9 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 27 | 14.44 | 461 | 180 | 0.18 / 334.92 | 3 | 3 |
2 | 3 | 932.28 | -1 | 14.44 | 461 | 0 | 0.00 / 334.92 | 3 | 3 |
3 | 7 | 2001.56 | 53 | 11.07 | 3265 | 1916 | 2.10 / 336.83 | 3 | 3 |
4 | 13 | 1737.52 | 25 | 12.86 | 2893 | 930 | 3.03 / 337.76 | 2 | 3 |
5 | 13 | 1174.64 | 25 | 13.35 | 2008 | 670 | 3.70 / 338.43 | 2 | 3 |
6 | 13 | 585.32 | 25 | 13.81 | 1172 | 405 | 4.10 / 338.84 | 2 | 3 |
7 | 13 | 1.04 | 25 | 14.40 | 323 | 116 | 4.22 / 338.96 | 3 | 3 |
8 | 8 | 0.24 | 180 | 14.18 | 310 | 791 | 5.01 / 339.75 | 3 | 5 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 27 | 14.41 | 476 | 185 | 0.19 / 329.93 | 3 | 3 |
2 | 7 | 2004.32 | 52 | 11.14 | 3268 | 1893 | 2.08 / 331.82 | 2 | 3 |
3 | 13 | 1747.88 | 25 | 12.86 | 2927 | 941 | 3.02 / 332.76 | 2 | 3 |
4 | 13 | 1194.40 | 25 | 13.32 | 2060 | 686 | 3.71 / 333.45 | 2 | 3 |
5 | 13 | 480.20 | 25 | 13.91 | 1029 | 358 | 4.06 / 333.81 | 2 | 3 |
6 | 13 | 30.76 | 25 | 14.35 | 369 | 132 | 4.20 / 333.94 | 3 | 3 |
7 | 8 | 0.00 | 180 | 14.19 | 313 | 799 | 4.99 / 334.74 | 3 | 16 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 27 | 14.43 | 477 | 186 | 0.19 / 324.86 | 3 | 3 |
2 | 7 | 2004.04 | 52 | 11.17 | 3279 | 1905 | 2.09 / 326.76 | 3 | 3 |
3 | 13 | 1879.04 | 25 | 12.71 | 3116 | 990 | 3.08 / 327.75 | 2 | 3 |
4 | 13 | 1289.56 | 25 | 13.26 | 2190 | 726 | 3.81 / 328.48 | 2 | 3 |
5 | 13 | 698.48 | 25 | 13.71 | 1350 | 463 | 4.27 / 328.94 | 2 | 3 |
6 | 8 | 0.08 | 180 | 14.22 | 314 | 804 | 5.07 / 329.74 | 3 | 8 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 27 | 14.45 | 471 | 184 | 0.18 / 319.81 | 3 | 3 |
2 | 3 | 969.24 | -1 | 14.45 | 471 | 0 | 0.00 / 319.81 | 3 | 3 |
3 | 3 | 1036.52 | 1 | 13.24 | 1929 | 26 | 0.21 / 319.84 | 2 | 3 |
4 | 7 | 2008.16 | 52 | 11.24 | 3285 | 1920 | 2.13 / 321.76 | 3 | 3 |
5 | 13 | 1885.04 | 25 | 12.72 | 3132 | 996 | 3.13 / 322.76 | 2 | 3 |
6 | 13 | 1426.80 | 25 | 13.18 | 2404 | 792 | 3.92 / 323.55 | 2 | 3 |
7 | 13 | 396.04 | 25 | 13.98 | 905 | 316 | 4.23 / 323.86 | 2 | 3 |
8 | 8 | 0.08 | 180 | 14.22 | 315 | 806 | 5.04 / 324.67 | 3 | 6 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 27 | 14.45 | 479 | 187 | 0.19 / 314.94 | 3 | 3 |
2 | 7 | 2003.04 | 52 | 11.27 | 3278 | 1921 | 2.11 / 316.86 | 3 | 3 |
3 | 13 | 1869.76 | 25 | 12.74 | 3099 | 987 | 3.09 / 317.85 | 2 | 3 |
4 | 13 | 1147.56 | 25 | 13.37 | 1988 | 664 | 3.76 / 318.51 | 2 | 3 |
5 | 13 | 415.72 | 25 | 13.97 | 924 | 323 | 4.08 / 318.83 | 2 | 3 |
6 | 8 | 0.00 | 180 | 14.23 | 311 | 797 | 4.88 / 319.63 | 2 | 11 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 27 | 14.47 | 455 | 178 | 0.18 / 309.92 | 3 | 3 |
2 | 7 | 2005.08 | 52 | 11.36 | 3278 | 1936 | 2.11 / 311.86 | 3 | 3 |
3 | 13 | 1881.28 | 25 | 12.78 | 3120 | 997 | 3.11 / 312.86 | 2 | 3 |
4 | 13 | 1146.20 | 25 | 13.39 | 1971 | 660 | 3.77 / 313.52 | 2 | 3 |
5 | 13 | 438.28 | 25 | 13.97 | 942 | 329 | 4.10 / 313.85 | 2 | 3 |
6 | 13 | 7.24 | 25 | 14.39 | 328 | 118 | 4.22 / 313.96 | 2 | 3 |
7 | 8 | 0.12 | 180 | 14.18 | 309 | 789 | 5.01 / 314.75 | 3 | 5 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 27 | 14.49 | 453 | 177 | 0.18 / 304.92 | 3 | 3 |
2 | 7 | 2005.88 | 52 | 11.39 | 3288 | 1947 | 2.12 / 306.86 | 3 | 3 |
3 | 13 | 1874.76 | 25 | 12.79 | 3109 | 994 | 3.12 / 307.86 | 2 | 3 |
4 | 13 | 1277.72 | 25 | 13.32 | 2154 | 717 | 3.84 / 308.57 | 2 | 3 |
5 | 13 | 536.36 | 25 | 13.90 | 1099 | 382 | 4.22 / 308.96 | 2 | 3 |
6 | 8 | -0.08 | 180 | 14.24 | 308 | 789 | 5.01 / 309.75 | 3 | 9 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 27 | 14.50 | 463 | 181 | 0.18 / 299.98 | 3 | 3 |
2 | 7 | 2002.92 | 53 | 11.50 | 3284 | 2002 | 2.18 / 301.98 | 3 | 3 |
3 | 13 | 1727.60 | 25 | 12.97 | 2849 | 924 | 3.11 / 302.91 | 2 | 3 |
4 | 13 | 1150.64 | 25 | 13.44 | 1930 | 648 | 3.76 / 303.55 | 2 | 3 |
5 | 13 | 564.72 | 25 | 13.88 | 1139 | 395 | 4.15 / 303.95 | 2 | 3 |
6 | 8 | 0.04 | 180 | 14.24 | 308 | 789 | 4.94 / 304.74 | 3 | 11 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 27 | 14.49 | 470 | 184 | 0.18 / 295.22 | 3 | 3 |
2 | 7 | 2002.40 | 53 | 11.58 | 3294 | 2022 | 2.21 / 297.24 | 3 | 3 |
3 | 13 | 1610.56 | 25 | 13.10 | 2669 | 874 | 3.08 / 298.12 | 2 | 3 |
4 | 13 | 1040.64 | 25 | 13.56 | 1761 | 597 | 3.68 / 298.72 | 2 | 3 |
5 | 13 | 332.64 | 25 | 14.08 | 816 | 287 | 3.96 / 299.00 | 2 | 3 |
6 | 8 | -0.08 | 180 | 14.26 | 310 | 796 | 4.76 / 299.80 | 3 | 14 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 27 | 14.54 | 452 | 177 | 0.18 / 290.30 | 3 | 3 |
2 | 7 | 2003.12 | 52 | 11.68 | 3288 | 1997 | 2.17 / 292.30 | 3 | 3 |
3 | 13 | 1876.84 | 25 | 12.86 | 3078 | 990 | 3.16 / 293.29 | 2 | 3 |
4 | 13 | 1152.08 | 25 | 13.44 | 1995 | 670 | 3.83 / 293.96 | 2 | 3 |
5 | 13 | 311.04 | 25 | 14.10 | 798 | 281 | 4.12 / 294.24 | 2 | 3 |
6 | 8 | 0.48 | 180 | 14.26 | 310 | 796 | 4.91 / 295.04 | 3 | 5 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 27 | 14.54 | 448 | 176 | 0.18 / 285.34 | 3 | 3 |
2 | 7 | 2008.32 | 52 | 11.78 | 3308 | 2026 | 2.20 / 287.37 | 3 | 3 |
3 | 13 | 1881.20 | 25 | 12.86 | 3119 | 1003 | 3.20 / 288.37 | 2 | 3 |
4 | 13 | 1132.68 | 25 | 13.47 | 1943 | 654 | 3.86 / 289.03 | 2 | 3 |
5 | 13 | 389.84 | 25 | 14.02 | 913 | 320 | 4.18 / 289.35 | 2 | 3 |
6 | 8 | 0.00 | 180 | 14.27 | 304 | 781 | 4.96 / 290.13 | 3 | 11 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 27 | 14.56 | 447 | 176 | 0.18 / 280.51 | 3 | 3 |
2 | 7 | 2003.76 | 52 | 11.86 | 3289 | 2028 | 2.20 / 282.54 | 3 | 3 |
3 | 13 | 1607.72 | 25 | 13.13 | 2692 | 884 | 3.09 / 283.42 | 2 | 3 |
4 | 13 | 1047.00 | 25 | 13.56 | 1792 | 607 | 3.70 / 284.03 | 2 | 3 |
5 | 13 | 461.76 | 25 | 14.00 | 999 | 350 | 4.04 / 284.38 | 2 | 3 |
6 | 8 | -0.12 | 180 | 14.28 | 306 | 787 | 4.83 / 285.17 | 3 | 8 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 27 | 14.58 | 443 | 174 | 0.17 / 275.65 | 3 | 3 |
2 | 7 | 2006.60 | 52 | 11.99 | 3283 | 2047 | 2.22 / 277.70 | 3 | 3 |
3 | 13 | 1747.16 | 25 | 13.05 | 2880 | 940 | 3.16 / 278.64 | 2 | 3 |
4 | 13 | 1160.80 | 25 | 13.49 | 1965 | 663 | 3.82 / 279.30 | 2 | 3 |
5 | 13 | 264.16 | 25 | 14.16 | 724 | 256 | 4.08 / 279.56 | 2 | 3 |
6 | 8 | -0.28 | 180 | 14.30 | 303 | 780 | 4.86 / 280.34 | 3 | 11 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 27 | 14.60 | 449 | 177 | 0.18 / 271.07 | 3 | 3 |
2 | 7 | 2002.48 | 51 | 12.03 | 3290 | 2019 | 2.20 / 273.08 | 2 | 3 |
3 | 13 | 1625.20 | 25 | 13.15 | 2715 | 893 | 3.09 / 273.98 | 2 | 3 |
4 | 13 | 832.48 | 25 | 13.72 | 1514 | 519 | 3.61 / 274.50 | 2 | 3 |
5 | 13 | 82.12 | 25 | 14.36 | 442 | 159 | 3.77 / 274.65 | 2 | 3 |
6 | 8 | 0.00 | 190 | 14.27 | 303 | 822 | 4.59 / 275.48 | 3 | 4 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 27 | 14.60 | 445 | 175 | 0.18 / 266.52 | 3 | 3 |
2 | 7 | 2003.44 | 50 | 12.13 | 3295 | 1998 | 2.17 / 268.52 | 2 | 3 |
3 | 13 | 1500.24 | 25 | 13.24 | 2495 | 826 | 3.00 / 269.34 | 2 | 3 |
4 | 13 | 860.88 | 25 | 13.72 | 1534 | 526 | 3.53 / 269.87 | 2 | 3 |
5 | 13 | 170.60 | 25 | 14.26 | 574 | 205 | 3.73 / 270.07 | 2 | 3 |
6 | 8 | 0.08 | 190 | 14.30 | 300 | 815 | 4.55 / 270.89 | 3 | 4 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 27 | 14.58 | 442 | 174 | 0.17 / 261.99 | 3 | 3 |
2 | 7 | 2005.44 | 50 | 12.20 | 3294 | 2009 | 2.18 / 264.00 | 2 | 3 |
3 | 13 | 1516.44 | 25 | 13.23 | 2531 | 837 | 3.02 / 264.84 | 2 | 3 |
4 | 13 | 858.08 | 25 | 13.72 | 1545 | 530 | 3.55 / 265.37 | 2 | 3 |
5 | 13 | 80.28 | 25 | 14.36 | 443 | 159 | 3.71 / 265.52 | 2 | 3 |
6 | 8 | -0.24 | 190 | 14.27 | 302 | 819 | 4.53 / 266.34 | 3 | 7 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 27 | 14.59 | 448 | 176 | 0.18 / 257.46 | 3 | 3 |
2 | 7 | 2002.32 | 50 | 12.21 | 3296 | 2012 | 2.19 / 259.47 | 2 | 3 |
3 | 13 | 1491.40 | 25 | 13.24 | 2513 | 832 | 3.02 / 260.30 | 2 | 3 |
4 | 13 | 843.40 | 25 | 13.73 | 1536 | 527 | 3.55 / 260.83 | 2 | 3 |
5 | 13 | 72.20 | 25 | 14.37 | 428 | 154 | 3.70 / 260.98 | 2 | 3 |
6 | 8 | -0.08 | 190 | 14.26 | 307 | 832 | 4.53 / 261.81 | 3 | 6 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 27 | 14.60 | 437 | 172 | 0.17 / 252.91 | 3 | 3 |
2 | 7 | 2003.16 | 51 | 12.21 | 3294 | 2051 | 2.22 / 254.96 | 3 | 3 |
3 | 13 | 1493.04 | 25 | 13.26 | 2488 | 825 | 3.05 / 255.79 | 2 | 3 |
4 | 13 | 832.28 | 25 | 13.75 | 1507 | 518 | 3.57 / 256.30 | 2 | 3 |
5 | 13 | 74.16 | 25 | 14.37 | 435 | 156 | 3.72 / 256.46 | 2 | 3 |
6 | 8 | -0.04 | 190 | 14.26 | 303 | 821 | 4.54 / 257.28 | 3 | 10 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 27 | 14.61 | 442 | 174 | 0.17 / 248.29 | 3 | 3 |
2 | 7 | 2005.40 | 51 | 12.23 | 3300 | 2058 | 2.23 / 250.35 | 3 | 3 |
3 | 13 | 1602.60 | 25 | 13.18 | 2657 | 875 | 3.11 / 251.22 | 2 | 3 |
4 | 13 | 800.00 | 25 | 13.77 | 1450 | 499 | 3.61 / 251.72 | 2 | 3 |
5 | 13 | 122.36 | 25 | 14.32 | 509 | 182 | 3.79 / 251.91 | 2 | 3 |
6 | 8 | -0.20 | 190 | 14.26 | 307 | 832 | 4.62 / 252.74 | 3 | 5 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 27 | 14.59 | 451 | 178 | 0.18 / 243.69 | 3 | 3 |
2 | 7 | 2003.00 | 51 | 12.24 | 3288 | 2053 | 2.23 / 245.75 | 2 | 3 |
3 | 13 | 1501.16 | 25 | 13.26 | 2505 | 830 | 3.06 / 246.58 | 2 | 3 |
4 | 13 | 845.68 | 25 | 13.73 | 1523 | 523 | 3.58 / 247.10 | 2 | 3 |
5 | 13 | 147.92 | 25 | 14.31 | 540 | 193 | 3.78 / 247.29 | 2 | 3 |
6 | 8 | 0.00 | 190 | 14.30 | 303 | 823 | 4.60 / 248.12 | 3 | 5 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 27 | 14.60 | 447 | 176 | 0.18 / 239.14 | 3 | 3 |
2 | 7 | 2005.56 | 51 | 12.20 | 3300 | 2053 | 2.23 / 241.19 | 3 | 3 |
3 | 13 | 1404.12 | 25 | 13.28 | 2385 | 792 | 3.02 / 241.98 | 2 | 3 |
4 | 13 | 882.36 | 25 | 13.70 | 1593 | 546 | 3.57 / 242.53 | 2 | 3 |
5 | 13 | 88.32 | 25 | 14.37 | 453 | 163 | 3.73 / 242.69 | 2 | 3 |
6 | 8 | -0.20 | 190 | 14.27 | 304 | 824 | 4.55 / 243.52 | 3 | 5 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 27 | 14.59 | 454 | 179 | 0.18 / 234.53 | 3 | 3 |
2 | 7 | 2003.04 | 50 | 12.14 | 3290 | 1997 | 2.18 / 236.53 | 2 | 3 |
3 | 13 | 1748.00 | 25 | 13.03 | 2877 | 937 | 3.11 / 237.46 | 2 | 3 |
4 | 13 | 827.44 | 25 | 13.73 | 1494 | 513 | 3.63 / 237.98 | 2 | 3 |
5 | 13 | 83.72 | 25 | 14.39 | 446 | 160 | 3.79 / 238.14 | 2 | 3 |
6 | 8 | 0.08 | 190 | 14.28 | 305 | 828 | 4.61 / 238.96 | 3 | 4 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 26 | 14.59 | 444 | 168 | 0.17 / 229.84 | 3 | 3 |
2 | 7 | 2004.32 | 50 | 12.10 | 3288 | 1989 | 2.16 / 231.83 | 2 | 3 |
3 | 13 | 1403.20 | 33 | 13.16 | 2342 | 1017 | 3.17 / 232.85 | 2 | 3 |
4 | 13 | 543.20 | 33 | 13.88 | 1119 | 513 | 3.69 / 233.36 | 2 | 3 |
5 | 13 | 21.44 | 33 | 14.44 | 347 | 165 | 3.85 / 233.52 | 2 | 3 |
6 | 8 | 0.04 | 190 | 14.24 | 305 | 825 | 4.68 / 234.35 | 3 | 14 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 26 | 14.58 | 452 | 171 | 0.17 / 224.98 | 3 | 3 |
2 | 7 | 2003.08 | 50 | 12.04 | 3286 | 1978 | 2.15 / 226.96 | 3 | 3 |
3 | 13 | 1575.72 | 33 | 13.01 | 2605 | 1118 | 3.27 / 228.08 | 2 | 3 |
4 | 13 | 683.08 | 33 | 13.75 | 1311 | 595 | 3.86 / 228.67 | 2 | 3 |
5 | 13 | 32.60 | 33 | 14.43 | 366 | 174 | 4.04 / 228.85 | 2 | 3 |
6 | 8 | -0.16 | 190 | 14.24 | 304 | 823 | 4.86 / 229.67 | 3 | 10 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 26 | 14.57 | 462 | 175 | 0.18 / 220.30 | 3 | 3 |
2 | 7 | 2005.04 | 50 | 12.08 | 3297 | 1991 | 2.17 / 222.30 | 2 | 3 |
3 | 13 | 1399.08 | 33 | 13.12 | 2340 | 1013 | 3.18 / 223.31 | 2 | 3 |
4 | 13 | 550.56 | 33 | 13.88 | 1109 | 508 | 3.69 / 223.82 | 2 | 3 |
5 | 13 | 20.00 | 33 | 14.45 | 346 | 165 | 3.85 / 223.98 | 2 | 3 |
6 | 8 | -0.04 | 190 | 14.24 | 307 | 831 | 4.68 / 224.81 | 3 | 10 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 26 | 14.57 | 460 | 174 | 0.17 / 215.63 | 3 | 3 |
2 | 7 | 2001.60 | 50 | 12.08 | 3289 | 1987 | 2.16 / 217.62 | 3 | 3 |
3 | 13 | 1574.68 | 33 | 12.99 | 2598 | 1114 | 3.27 / 218.73 | 2 | 3 |
4 | 13 | 651.44 | 33 | 13.81 | 1221 | 556 | 3.83 / 219.29 | 2 | 3 |
5 | 8 | 0.16 | 190 | 14.29 | 310 | 842 | 4.67 / 220.13 | 3 | 13 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 26 | 14.58 | 459 | 174 | 0.17 / 210.78 | 3 | 3 |
2 | 7 | 2002.32 | 50 | 12.08 | 3283 | 1983 | 2.16 / 212.77 | 2 | 3 |
3 | 13 | 1573.52 | 33 | 13.00 | 2599 | 1115 | 3.27 / 213.88 | 2 | 3 |
4 | 13 | 667.64 | 33 | 13.78 | 1291 | 587 | 3.86 / 214.47 | 2 | 3 |
5 | 13 | 9.12 | 33 | 14.47 | 328 | 157 | 4.02 / 214.62 | 2 | 3 |
6 | 8 | 0.12 | 190 | 14.25 | 307 | 831 | 4.85 / 215.46 | 3 | 9 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 26 | 14.56 | 463 | 175 | 0.18 / 206.21 | 3 | 3 |
2 | 7 | 2005.24 | 50 | 12.12 | 3279 | 1987 | 2.16 / 208.19 | 2 | 3 |
3 | 13 | 1587.44 | 33 | 13.00 | 2603 | 1117 | 3.28 / 209.31 | 2 | 3 |
4 | 13 | 485.08 | 33 | 13.97 | 1013 | 467 | 3.75 / 209.78 | 2 | 3 |
5 | 8 | 0.16 | 190 | 14.32 | 306 | 833 | 4.58 / 210.61 | 2 | 9 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 26 | 14.56 | 458 | 173 | 0.17 / 201.73 | 3 | 3 |
2 | 7 | 2006.16 | 50 | 12.13 | 3280 | 1989 | 2.16 / 203.72 | 2 | 3 |
3 | 13 | 1390.68 | 33 | 13.14 | 2305 | 999 | 3.16 / 204.72 | 2 | 3 |
4 | 13 | 506.08 | 33 | 13.96 | 1021 | 470 | 3.63 / 205.19 | 2 | 3 |
5 | 8 | -0.16 | 190 | 14.29 | 309 | 839 | 4.47 / 206.03 | 3 | 11 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 26 | 14.58 | 472 | 179 | 0.18 / 197.07 | 3 | 3 |
2 | 7 | 2004.36 | 50 | 12.16 | 3289 | 2000 | 2.18 / 199.07 | 2 | 3 |
3 | 13 | 1401.52 | 33 | 13.17 | 2344 | 1019 | 3.20 / 200.09 | 2 | 3 |
4 | 13 | 721.16 | 33 | 13.74 | 1377 | 624 | 3.82 / 200.71 | 2 | 3 |
5 | 8 | 0.12 | 190 | 14.31 | 312 | 848 | 4.67 / 201.56 | 3 | 11 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 26 | 14.60 | 467 | 177 | 0.18 / 192.55 | 3 | 3 |
2 | 7 | 2006.00 | 50 | 12.22 | 3291 | 2011 | 2.19 / 194.56 | 2 | 3 |
3 | 13 | 1385.16 | 33 | 13.20 | 2300 | 1002 | 3.19 / 195.56 | 2 | 3 |
4 | 13 | 494.72 | 33 | 13.99 | 1034 | 477 | 3.67 / 196.04 | 2 | 3 |
5 | 8 | 0.28 | 190 | 14.32 | 312 | 849 | 4.52 / 196.89 | 3 | 16 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 26 | 14.61 | 466 | 177 | 0.18 / 187.68 | 3 | 3 |
2 | 7 | 2001.40 | 50 | 12.27 | 3284 | 2015 | 2.19 / 189.69 | 2 | 3 |
3 | 13 | 1579.72 | 33 | 13.09 | 2604 | 1125 | 3.32 / 190.82 | 2 | 3 |
4 | 13 | 638.04 | 33 | 13.87 | 1245 | 570 | 3.89 / 191.39 | 2 | 3 |
5 | 13 | 9.92 | 33 | 14.52 | 329 | 158 | 4.04 / 191.54 | 3 | 3 |
6 | 8 | -0.16 | 190 | 14.28 | 306 | 830 | 4.87 / 192.37 | 3 | 8 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 26 | 14.60 | 469 | 178 | 0.18 / 183.12 | 3 | 3 |
2 | 7 | 2005.80 | 50 | 12.33 | 3297 | 2033 | 2.21 / 185.15 | 3 | 3 |
3 | 13 | 1390.68 | 33 | 13.25 | 2333 | 1020 | 3.23 / 186.17 | 2 | 3 |
4 | 13 | 506.40 | 33 | 14.01 | 1062 | 491 | 3.72 / 186.66 | 2 | 3 |
5 | 8 | -0.08 | 190 | 14.34 | 307 | 836 | 4.56 / 187.50 | 2 | 10 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 26 | 14.61 | 476 | 181 | 0.18 / 178.38 | 3 | 3 |
2 | 7 | 2000.84 | 50 | 12.39 | 3284 | 2034 | 2.22 / 180.42 | 2 | 3 |
3 | 13 | 1557.72 | 33 | 13.15 | 2587 | 1123 | 3.34 / 181.54 | 2 | 3 |
4 | 13 | 621.64 | 33 | 13.92 | 1212 | 557 | 3.89 / 182.10 | 2 | 3 |
5 | 8 | 0.32 | 190 | 14.33 | 310 | 844 | 4.74 / 182.94 | 3 | 14 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 26 | 14.61 | 470 | 179 | 0.18 / 173.67 | 3 | 3 |
2 | 7 | 2003.12 | 51 | 12.46 | 3296 | 2094 | 2.27 / 175.77 | 3 | 3 |
3 | 13 | 1568.52 | 33 | 13.16 | 2613 | 1135 | 3.41 / 176.90 | 2 | 3 |
4 | 13 | 441.24 | 33 | 14.11 | 953 | 444 | 3.85 / 177.35 | 2 | 3 |
5 | 8 | 0.00 | 190 | 14.36 | 313 | 854 | 4.71 / 178.20 | 2 | 13 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 26 | 14.65 | 466 | 177 | 0.18 / 169.00 | 3 | 3 |
2 | 7 | 2001.24 | 50 | 12.49 | 3290 | 2055 | 2.23 / 171.06 | 2 | 3 |
3 | 13 | 1575.64 | 33 | 13.19 | 2599 | 1131 | 3.36 / 172.19 | 2 | 3 |
4 | 13 | 469.04 | 33 | 14.09 | 1001 | 465 | 3.83 / 172.65 | 2 | 3 |
5 | 8 | 0.20 | 190 | 14.37 | 309 | 844 | 4.67 / 173.50 | 3 | 3 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 26 | 14.63 | 478 | 182 | 0.18 / 164.42 | 3 | 3 |
2 | 7 | 2002.36 | 50 | 12.56 | 3293 | 2068 | 2.25 / 166.49 | 3 | 3 |
3 | 13 | 1372.80 | 33 | 13.34 | 2317 | 1020 | 3.27 / 167.51 | 2 | 3 |
4 | 13 | 489.28 | 33 | 14.08 | 1022 | 475 | 3.74 / 167.98 | 2 | 3 |
5 | 8 | 0.12 | 190 | 14.38 | 308 | 842 | 4.59 / 168.82 | 3 | 6 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 26 | 14.65 | 474 | 181 | 0.18 / 159.79 | 3 | 3 |
2 | 7 | 2004.72 | 51 | 12.62 | 3278 | 2110 | 2.29 / 161.90 | 3 | 3 |
3 | 13 | 1387.80 | 33 | 13.36 | 2295 | 1012 | 3.30 / 162.91 | 2 | 3 |
4 | 13 | 493.80 | 33 | 14.08 | 1031 | 479 | 3.78 / 163.39 | 2 | 3 |
5 | 8 | 0.80 | 190 | 14.36 | 310 | 846 | 4.63 / 164.24 | 2 | 3 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 26 | 14.66 | 461 | 176 | 0.18 / 155.22 | 3 | 3 |
2 | 7 | 2004.24 | 50 | 12.65 | 3276 | 2072 | 2.25 / 157.29 | 3 | 3 |
3 | 13 | 1372.44 | 33 | 13.38 | 2281 | 1007 | 3.25 / 158.30 | 2 | 3 |
4 | 13 | 480.08 | 33 | 14.10 | 1017 | 473 | 3.73 / 158.77 | 2 | 3 |
5 | 8 | -0.16 | 190 | 14.38 | 308 | 842 | 4.57 / 159.61 | 3 | 7 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 25 | 14.68 | 470 | 172 | 0.17 / 150.49 | 3 | 3 |
2 | 7 | 2003.76 | 50 | 12.59 | 3272 | 2060 | 2.23 / 152.55 | 2 | 3 |
3 | 13 | 1386.28 | 33 | 13.36 | 2305 | 1016 | 3.25 / 153.56 | 2 | 3 |
4 | 13 | 500.28 | 33 | 14.09 | 1040 | 484 | 3.73 / 154.05 | 2 | 3 |
5 | 13 | 10.68 | 33 | 14.58 | 331 | 159 | 3.89 / 154.21 | 3 | 3 |
6 | 8 | 0.04 | 190 | 14.32 | 307 | 835 | 4.73 / 155.04 | 3 | 14 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 25 | 14.67 | 463 | 170 | 0.17 / 145.94 | 3 | 3 |
2 | 7 | 2002.88 | 50 | 12.72 | 3267 | 2078 | 2.25 / 148.02 | 3 | 3 |
3 | 13 | 1361.52 | 33 | 13.42 | 2252 | 997 | 3.24 / 149.02 | 2 | 3 |
4 | 13 | 460.88 | 33 | 14.15 | 980 | 458 | 3.70 / 149.47 | 2 | 3 |
5 | 8 | 0.24 | 190 | 14.39 | 307 | 839 | 4.54 / 150.31 | 3 | 7 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 26 | 14.66 | 472 | 180 | 0.18 / 141.30 | 3 | 3 |
2 | 3 | 968.76 | -1 | 14.66 | 472 | 0 | 0.00 / 141.30 | 3 | 3 |
3 | 3 | 1038.96 | 1 | 14.27 | 1941 | 28 | 0.21 / 141.33 | 2 | 3 |
4 | 7 | 2004.80 | 51 | 12.71 | 3270 | 2120 | 2.33 / 143.45 | 3 | 3 |
5 | 13 | 1382.28 | 33 | 13.41 | 2285 | 1011 | 3.34 / 144.46 | 2 | 3 |
6 | 13 | 488.20 | 33 | 14.12 | 1009 | 470 | 3.81 / 144.93 | 2 | 3 |
7 | 8 | -0.16 | 190 | 14.39 | 308 | 842 | 4.65 / 145.77 | 3 | 4 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 26 | 14.68 | 472 | 180 | 0.18 / 136.72 | 3 | 3 |
2 | 7 | 2001.68 | 50 | 12.76 | 3276 | 2090 | 2.27 / 138.81 | 3 | 3 |
3 | 13 | 1377.08 | 33 | 13.42 | 2283 | 1011 | 3.28 / 139.82 | 2 | 3 |
4 | 13 | 472.24 | 33 | 14.15 | 978 | 457 | 3.74 / 140.28 | 2 | 3 |
5 | 8 | -0.04 | 190 | 14.40 | 309 | 845 | 4.58 / 141.12 | 3 | 11 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 26 | 14.69 | 462 | 176 | 0.18 / 132.14 | 3 | 3 |
2 | 7 | 2001.72 | 50 | 12.76 | 3264 | 2082 | 2.26 / 134.22 | 2 | 3 |
3 | 13 | 1361.92 | 33 | 13.44 | 2260 | 1002 | 3.26 / 135.22 | 2 | 3 |
4 | 13 | 482.92 | 33 | 14.13 | 1019 | 475 | 3.74 / 135.70 | 2 | 3 |
5 | 8 | 0.20 | 190 | 14.39 | 308 | 842 | 4.58 / 136.54 | 3 | 3 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 27 | 14.69 | 459 | 182 | 0.18 / 127.53 | 3 | 3 |
2 | 3 | 952.60 | -1 | 14.69 | 459 | 0 | 0.00 / 127.53 | 3 | 3 |
3 | 7 | 2005.72 | 50 | 12.79 | 3279 | 2097 | 2.28 / 129.62 | 2 | 3 |
4 | 13 | 1385.36 | 33 | 13.42 | 2311 | 1023 | 3.30 / 130.65 | 2 | 3 |
5 | 13 | 502.96 | 33 | 14.13 | 1026 | 478 | 3.78 / 131.13 | 2 | 3 |
6 | 8 | -0.12 | 190 | 14.40 | 305 | 834 | 4.62 / 131.96 | 3 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 27 | 14.70 | 464 | 184 | 0.18 / 122.87 | 3 | 3 |
2 | 7 | 2003.76 | 51 | 12.82 | 3282 | 2146 | 2.33 / 125.02 | 3 | 3 |
3 | 13 | 1369.84 | 33 | 13.44 | 2304 | 1022 | 3.35 / 126.04 | 2 | 3 |
4 | 13 | 476.40 | 33 | 14.17 | 980 | 458 | 3.81 / 126.50 | 2 | 3 |
5 | 8 | 0.04 | 190 | 14.42 | 308 | 844 | 4.65 / 127.34 | 3 | 3 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 27 | 14.73 | 448 | 178 | 0.18 / 118.37 | 3 | 3 |
2 | 3 | 967.56 | -1 | 14.73 | 448 | 0 | 0.00 / 118.37 | 3 | 3 |
3 | 3 | 1034.40 | 1 | 14.39 | 1925 | 28 | 0.21 / 118.40 | 2 | 3 |
4 | 7 | 2004.64 | 51 | 12.85 | 3280 | 2150 | 2.36 / 120.55 | 3 | 3 |
5 | 13 | 1198.04 | 33 | 13.56 | 2044 | 915 | 3.27 / 121.46 | 2 | 3 |
6 | 13 | 329.88 | 33 | 14.28 | 810 | 382 | 3.65 / 121.84 | 2 | 3 |
7 | 8 | 0.08 | 190 | 14.40 | 310 | 848 | 4.50 / 122.69 | 3 | 4 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 27 | 14.74 | 457 | 182 | 0.18 / 113.74 | 3 | 3 |
2 | 7 | 2002.88 | 50 | 12.84 | 3282 | 2107 | 2.29 / 115.85 | 2 | 3 |
3 | 13 | 1372.84 | 33 | 13.44 | 2313 | 1026 | 3.31 / 116.88 | 2 | 3 |
4 | 13 | 467.92 | 33 | 14.16 | 1001 | 468 | 3.78 / 117.34 | 2 | 3 |
5 | 8 | -0.08 | 190 | 14.41 | 309 | 846 | 4.63 / 118.19 | 3 | 4 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 27 | 14.76 | 440 | 175 | 0.18 / 109.19 | 3 | 3 |
2 | 7 | 2004.48 | 50 | 12.85 | 3256 | 2092 | 2.27 / 111.28 | 3 | 3 |
3 | 13 | 1353.32 | 33 | 13.47 | 2234 | 993 | 3.26 / 112.27 | 2 | 3 |
4 | 13 | 463.36 | 33 | 14.18 | 969 | 453 | 3.71 / 112.72 | 2 | 3 |
5 | 8 | 0.04 | 190 | 14.42 | 306 | 838 | 4.55 / 113.56 | 3 | 4 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 26 | 14.75 | 447 | 171 | 0.17 / 104.57 | 3 | 3 |
2 | 3 | 1028.84 | 1 | 14.44 | 1944 | 28 | 0.20 / 104.60 | 2 | 3 |
3 | 7 | 2004.12 | 50 | 12.87 | 3283 | 2113 | 2.31 / 106.71 | 2 | 3 |
4 | 13 | 1347.12 | 33 | 13.47 | 2260 | 1005 | 3.32 / 107.71 | 2 | 3 |
5 | 13 | 456.96 | 33 | 14.18 | 976 | 457 | 3.77 / 108.17 | 2 | 3 |
6 | 8 | 0.00 | 190 | 14.42 | 306 | 838 | 4.61 / 109.01 | 3 | 3 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 27 | 14.77 | 432 | 172 | 0.17 / 99.99 | 3 | 3 |
2 | 3 | 959.56 | -1 | 14.77 | 432 | 0 | 0.00 / 99.99 | 3 | 3 |
3 | 3 | 1018.60 | 1 | 14.35 | 1908 | 27 | 0.20 / 100.01 | 2 | 3 |
4 | 7 | 2002.60 | 50 | 12.90 | 3251 | 2097 | 2.30 / 102.11 | 3 | 3 |
5 | 13 | 1370.72 | 33 | 13.47 | 2256 | 1003 | 3.30 / 103.11 | 2 | 3 |
6 | 13 | 466.20 | 33 | 14.19 | 966 | 452 | 3.75 / 103.57 | 2 | 3 |
7 | 8 | -0.28 | 190 | 14.42 | 304 | 833 | 4.58 / 104.40 | 3 | 5 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 27 | 14.77 | 438 | 175 | 0.17 / 95.45 | 3 | 3 |
2 | 7 | 2002.12 | 50 | 12.90 | 3231 | 2084 | 2.26 / 97.54 | 2 | 3 |
3 | 13 | 1376.20 | 28 | 13.52 | 2284 | 865 | 3.12 / 98.40 | 2 | 3 |
4 | 13 | 524.28 | 28 | 14.17 | 1087 | 431 | 3.55 / 98.83 | 2 | 3 |
5 | 13 | 50.68 | 28 | 14.61 | 395 | 162 | 3.72 / 99.00 | 2 | 3 |
6 | 8 | 0.04 | 190 | 14.43 | 298 | 817 | 4.53 / 99.81 | 3 | 9 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 27 | 14.77 | 441 | 176 | 0.18 / 90.95 | 3 | 3 |
2 | 7 | 2002.96 | 50 | 12.90 | 3257 | 2101 | 2.28 / 93.05 | 3 | 3 |
3 | 13 | 1365.60 | 28 | 13.53 | 2259 | 856 | 3.13 / 93.90 | 2 | 3 |
4 | 13 | 502.48 | 28 | 14.21 | 1020 | 406 | 3.54 / 94.31 | 2 | 3 |
5 | 13 | 28.48 | 28 | 14.65 | 356 | 146 | 3.68 / 94.46 | 2 | 3 |
6 | 8 | -0.12 | 190 | 14.41 | 301 | 824 | 4.51 / 95.28 | 3 | 10 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 26 | 14.78 | 443 | 170 | 0.17 / 86.28 | 3 | 3 |
2 | 7 | 2002.92 | 51 | 12.94 | 3246 | 2142 | 2.31 / 88.42 | 2 | 3 |
3 | 13 | 1348.92 | 28 | 13.55 | 2241 | 850 | 3.16 / 89.27 | 2 | 3 |
4 | 13 | 683.28 | 28 | 14.04 | 1321 | 519 | 3.68 / 89.79 | 2 | 3 |
5 | 13 | 33.24 | 28 | 14.64 | 365 | 150 | 3.83 / 89.94 | 2 | 3 |
6 | 8 | -0.04 | 190 | 14.40 | 303 | 829 | 4.66 / 90.77 | 3 | 8 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 26 | 14.79 | 440 | 169 | 0.17 / 81.73 | 3 | 3 |
2 | 7 | 2004.56 | 51 | 12.95 | 3234 | 2136 | 2.31 / 83.86 | 3 | 3 |
3 | 13 | 1357.20 | 28 | 13.54 | 2252 | 854 | 3.16 / 84.72 | 2 | 3 |
4 | 13 | 515.48 | 28 | 14.20 | 1044 | 415 | 3.57 / 85.13 | 2 | 3 |
5 | 13 | 31.96 | 28 | 14.65 | 365 | 150 | 3.72 / 85.28 | 2 | 3 |
6 | 8 | -0.08 | 190 | 14.41 | 303 | 830 | 4.55 / 86.11 | 3 | 12 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 26 | 14.78 | 451 | 173 | 0.17 / 77.13 | 3 | 3 |
2 | 7 | 2001.40 | 51 | 12.96 | 3259 | 2154 | 2.33 / 79.29 | 2 | 3 |
3 | 13 | 1363.84 | 28 | 13.54 | 2261 | 857 | 3.18 / 80.14 | 2 | 3 |
4 | 13 | 500.68 | 28 | 14.20 | 1045 | 415 | 3.60 / 80.56 | 2 | 3 |
5 | 13 | 49.00 | 28 | 14.63 | 390 | 160 | 3.76 / 80.72 | 2 | 3 |
6 | 8 | -0.16 | 190 | 14.40 | 307 | 840 | 4.60 / 81.56 | 3 | 14 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 26 | 14.78 | 451 | 173 | 0.17 / 72.60 | 3 | 3 |
2 | 7 | 2003.72 | 50 | 12.98 | 3214 | 2086 | 2.26 / 74.69 | 3 | 3 |
3 | 13 | 1362.24 | 28 | 13.56 | 2273 | 863 | 3.12 / 75.55 | 2 | 3 |
4 | 13 | 504.20 | 28 | 14.20 | 1048 | 417 | 3.54 / 75.97 | 2 | 3 |
5 | 13 | 27.24 | 28 | 14.66 | 360 | 148 | 3.69 / 76.12 | 2 | 3 |
6 | 8 | -0.24 | 190 | 14.40 | 308 | 843 | 4.53 / 76.96 | 3 | 9 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 26 | 14.78 | 455 | 175 | 0.17 / 67.96 | 3 | 3 |
2 | 7 | 2001.48 | 50 | 12.99 | 3229 | 2097 | 2.27 / 70.06 | 2 | 3 |
3 | 13 | 1349.64 | 28 | 13.56 | 2241 | 851 | 3.12 / 70.91 | 2 | 3 |
4 | 13 | 691.16 | 28 | 14.06 | 1301 | 512 | 3.64 / 71.42 | 2 | 3 |
5 | 13 | 41.44 | 28 | 14.65 | 386 | 158 | 3.79 / 71.58 | 2 | 3 |
6 | 8 | 0.08 | 190 | 14.40 | 310 | 848 | 4.64 / 72.43 | 3 | 12 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 26 | 14.80 | 443 | 170 | 0.17 / 63.32 | 3 | 3 |
2 | 7 | 2004.56 | 50 | 12.99 | 3233 | 2100 | 2.27 / 65.42 | 2 | 3 |
3 | 13 | 1363.88 | 28 | 13.55 | 2263 | 859 | 3.13 / 66.28 | 2 | 3 |
4 | 13 | 682.32 | 28 | 14.06 | 1282 | 505 | 3.63 / 66.79 | 2 | 3 |
5 | 13 | 38.20 | 28 | 14.66 | 380 | 156 | 3.79 / 66.94 | 2 | 3 |
6 | 8 | 0.04 | 190 | 14.40 | 309 | 845 | 4.63 / 67.79 | 3 | 12 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 26 | 14.77 | 448 | 172 | 0.17 / 58.75 | 3 | 3 |
2 | 7 | 2001.92 | 51 | 13.00 | 3226 | 2139 | 2.31 / 60.89 | 2 | 3 |
3 | 13 | 1366.04 | 28 | 13.54 | 2277 | 863 | 3.17 / 61.75 | 2 | 3 |
4 | 13 | 503.60 | 28 | 14.21 | 1045 | 416 | 3.59 / 62.16 | 2 | 3 |
5 | 13 | 24.40 | 28 | 14.69 | 353 | 145 | 3.74 / 62.31 | 2 | 3 |
6 | 8 | -0.24 | 190 | 14.40 | 308 | 843 | 4.58 / 63.15 | 3 | 13 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 25 | 14.79 | 452 | 167 | 0.17 / 54.23 | 3 | 3 |
2 | 7 | 2002.32 | 50 | 13.00 | 3232 | 2101 | 2.27 / 56.33 | 2 | 3 |
3 | 13 | 1344.16 | 28 | 13.55 | 2239 | 849 | 3.12 / 57.18 | 2 | 3 |
4 | 13 | 479.24 | 28 | 14.22 | 1022 | 407 | 3.52 / 57.59 | 2 | 3 |
5 | 13 | 20.40 | 28 | 14.71 | 344 | 142 | 3.67 / 57.73 | 2 | 3 |
6 | 8 | 0.00 | 190 | 14.41 | 308 | 843 | 4.51 / 58.57 | 3 | 11 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 25 | 14.78 | 453 | 167 | 0.17 / 49.70 | 3 | 3 |
2 | 7 | 2001.56 | 51 | 13.02 | 3206 | 2129 | 2.30 / 51.83 | 2 | 3 |
3 | 13 | 1350.80 | 28 | 13.56 | 2230 | 847 | 3.14 / 52.68 | 2 | 3 |
4 | 13 | 506.56 | 28 | 14.21 | 1038 | 413 | 3.56 / 53.09 | 2 | 3 |
5 | 13 | 22.48 | 28 | 14.72 | 347 | 143 | 3.70 / 53.23 | 2 | 3 |
6 | 8 | 0.08 | 190 | 14.42 | 304 | 833 | 4.53 / 54.07 | 3 | 12 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 25 | 14.78 | 455 | 168 | 0.17 / 45.11 | 3 | 3 |
2 | 7 | 2001.76 | 51 | 13.02 | 3228 | 2143 | 2.31 / 47.25 | 2 | 3 |
3 | 13 | 1332.12 | 27 | 13.59 | 2224 | 816 | 3.13 / 48.06 | 2 | 3 |
4 | 13 | 670.76 | 27 | 14.08 | 1298 | 493 | 3.62 / 48.56 | 2 | 3 |
5 | 13 | 16.60 | 27 | 14.73 | 343 | 136 | 3.76 / 48.69 | 2 | 3 |
6 | 8 | -0.16 | 190 | 14.38 | 307 | 839 | 4.60 / 49.53 | 3 | 8 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 25 | 14.77 | 461 | 170 | 0.17 / 40.58 | 3 | 3 |
2 | 7 | 2002.72 | 51 | 13.00 | 3225 | 2138 | 2.31 / 42.72 | 2 | 3 |
3 | 13 | 1352.00 | 25 | 13.61 | 2232 | 759 | 3.07 / 43.48 | 2 | 3 |
4 | 13 | 704.00 | 25 | 14.07 | 1351 | 475 | 3.54 / 43.95 | 2 | 3 |
5 | 13 | 46.84 | 25 | 14.71 | 390 | 143 | 3.69 / 44.10 | 2 | 3 |
6 | 8 | 0.20 | 190 | 14.41 | 307 | 841 | 4.53 / 44.94 | 3 | 8 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 25 | 14.76 | 469 | 173 | 0.17 / 36.11 | 3 | 3 |
2 | 7 | 2001.44 | 50 | 13.00 | 3218 | 2092 | 2.26 / 38.20 | 2 | 3 |
3 | 13 | 1338.68 | 25 | 13.59 | 2233 | 759 | 3.02 / 38.96 | 2 | 3 |
4 | 13 | 682.92 | 25 | 14.07 | 1317 | 463 | 3.49 / 39.42 | 2 | 3 |
5 | 13 | 42.52 | 25 | 14.70 | 393 | 144 | 3.63 / 39.57 | 3 | 3 |
6 | 8 | -0.04 | 190 | 14.40 | 308 | 843 | 4.47 / 40.41 | 3 | 11 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 24 | 14.72 | 468 | 165 | 0.17 / 31.62 | 3 | 3 |
2 | 7 | 2002.72 | 50 | 12.98 | 3228 | 2095 | 2.26 / 33.71 | 2 | 3 |
3 | 13 | 1354.12 | 25 | 13.56 | 2271 | 770 | 3.03 / 34.48 | 2 | 3 |
4 | 13 | 696.80 | 25 | 14.06 | 1314 | 462 | 3.49 / 34.95 | 2 | 3 |
5 | 13 | 48.84 | 25 | 14.69 | 396 | 145 | 3.64 / 35.09 | 2 | 3 |
6 | 8 | 0.08 | 190 | 14.39 | 309 | 845 | 4.48 / 35.94 | 3 | 8 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 24 | 14.69 | 474 | 167 | 0.17 / 27.17 | 3 | 3 |
2 | 7 | 2001.28 | 51 | 12.95 | 3225 | 2130 | 2.30 / 29.30 | 2 | 3 |
3 | 13 | 1353.44 | 25 | 13.56 | 2214 | 751 | 3.05 / 30.06 | 2 | 3 |
4 | 13 | 533.92 | 25 | 14.18 | 1105 | 392 | 3.44 / 30.45 | 2 | 3 |
5 | 13 | 60.76 | 25 | 14.66 | 416 | 152 | 3.59 / 30.60 | 2 | 3 |
6 | 8 | 0.28 | 190 | 14.37 | 313 | 855 | 4.45 / 31.45 | 3 | 5 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 23 | 14.69 | 470 | 159 | 0.16 / 22.15 | 3 | 3 |
2 | 7 | 2002.08 | 75 | 12.74 | 3237 | 3093 | 3.25 / 25.25 | 2 | 3 |
3 | 13 | 980.92 | 20 | 13.85 | 1730 | 479 | 3.73 / 25.73 | 2 | 3 |
4 | 13 | 283.04 | 20 | 14.44 | 750 | 217 | 3.95 / 25.94 | 2 | 3 |
5 | 8 | 0.00 | 240 | 14.37 | 309 | 1066 | 5.01 / 27.01 | 3 | 17 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 25 | 14.66 | 466 | 171 | 0.17 / 17.20 | 3 | 3 |
2 | 3 | 922.00 | -1 | 14.66 | 466 | 0 | 0.00 / 17.20 | 3 | 3 |
3 | 7 | 2003.60 | 75 | 12.68 | 3205 | 3048 | 3.22 / 20.25 | 3 | 3 |
4 | 13 | 995.36 | 20 | 13.83 | 1708 | 472 | 3.69 / 20.72 | 2 | 3 |
5 | 13 | 296.96 | 20 | 14.41 | 757 | 218 | 3.91 / 20.94 | 2 | 3 |
6 | 8 | 0.32 | 240 | 14.35 | 307 | 1057 | 4.97 / 21.99 | 3 | 18 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 23 | 14.63 | 481 | 162 | 0.16 / 13.01 | 3 | 3 |
2 | 7 | 1509.80 | 74 | 13.03 | 2520 | 2430 | 2.59 / 15.44 | 3 | 3 |
3 | 13 | 772.88 | 20 | 13.96 | 1415 | 395 | 2.99 / 15.83 | 2 | 3 |
4 | 13 | 77.40 | 20 | 14.63 | 443 | 130 | 3.12 / 15.96 | 2 | 3 |
5 | 8 | 0.20 | 240 | 14.31 | 310 | 1065 | 4.18 / 17.03 | 3 | 25 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 23 | 14.61 | 478 | 161 | 0.16 / 8.84 | 3 | 3 |
2 | 7 | 1504.72 | 74 | 12.96 | 2462 | 2361 | 2.52 / 11.20 | 3 | 3 |
3 | 13 | 786.24 | 20 | 13.88 | 1452 | 403 | 2.92 / 11.61 | 2 | 3 |
4 | 13 | 154.44 | 20 | 14.48 | 559 | 162 | 3.09 / 11.77 | 2 | 3 |
5 | 8 | 0.20 | 240 | 14.29 | 314 | 1077 | 4.16 / 12.85 | 3 | 23 |
Average= | 3.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 25 | 14.53 | 466 | 169 | 0.17 / 4.68 | 3 | 3 |
2 | 3 | 936.40 | -1 | 14.53 | 466 | 0 | 0.00 / 4.68 | 3 | 3 |
3 | 7 | 1514.20 | 75 | 12.74 | 2494 | 2383 | 2.55 / 7.06 | 3 | 3 |
4 | 13 | 786.00 | 20 | 13.79 | 1459 | 402 | 2.95 / 7.46 | 2 | 3 |
5 | 13 | 150.12 | 20 | 14.43 | 550 | 159 | 3.11 / 7.62 | 2 | 3 |
6 | 8 | 0.16 | 240 | 14.26 | 310 | 1061 | 4.17 / 8.68 | 3 | 23 |
Average= | 2.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 25 | 14.53 | 444 | 161 | 0.16 / 1.70 | 3 | 3 |
2 | 3 | 967.28 | -1 | 14.53 | 444 | 0 | 0.00 / 1.70 | 3 | 3 |
3 | 3 | 1034.32 | 1 | 13.72 | 1912 | 26 | 0.19 / 1.73 | 2 | 3 |
4 | 7 | 1010.72 | 75 | 12.92 | 1793 | 1737 | 1.92 / 3.47 | 3 | 3 |
5 | 8 | 0.04 | 240 | 14.22 | 305 | 1041 | 2.97 / 4.51 | 3 | 19 |
Average= | 2.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 85.08 | 24 | 14.42 | 420 | 145 | 0.15 / 0.15 | 3 | 3 |
2 | 7 | 93.44 | 74 | 14.17 | 428 | 449 | 0.59 / 0.59 | 3 | 3 |
3 | 8 | 0.32 | 240 | 14.27 | 277 | 949 | 1.54 / 1.54 | 3 | 61 |
Average= | 1.54 (KJ/cycle) |