SIO Argo Site:
Pump Diagnostics Page   



Serial= 3216 WMO= 4903769

Return

←PreviousNext→

Cycle 23 GMT 17/12/2024 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 27 15.19 479 196 0.20 / 91.65 2 4
2 7 2010.40 38 14.96 2833 1611 1.81 / 93.26 2 7
3 13 1341.72 18 15.04 2042 553 2.36 / 93.81 2 9
4 13 795.96 18 15.13 1375 374 2.73 / 94.18 2 10
5 13 376.60 18 15.23 840 230 2.96 / 94.41 2 11
6 13 127.80 18 15.27 528 145 3.11 / 94.56 2 11
7 8 0.08 165 15.24 333 837 3.95 / 95.40 2 14
Average= 3.97
(KJ/cycle)

Cycle 22 GMT 7/12/2024 5:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 27 15.20 482 198 0.20 / 87.65 2 4
2 7 2009.88 39 14.96 2834 1653 1.85 / 89.31 2 7
3 13 1357.24 18 15.05 2067 560 2.41 / 89.87 2 8
4 13 842.40 18 15.13 1419 386 2.80 / 90.25 2 10
5 13 326.92 18 15.24 788 216 3.01 / 90.47 2 11
6 13 92.16 18 15.28 479 132 3.15 / 90.60 2 11
7 8 0.16 165 15.24 338 850 4.00 / 91.45 2 15
Average= 3.98
(KJ/cycle)

Cycle 21 GMT 27/11/2024 9:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 27 15.18 469 192 0.19 / 83.63 2 4
2 7 2003.92 38 14.97 2824 1606 1.80 / 85.24 2 8
3 13 1408.88 18 15.04 2117 573 2.37 / 85.81 2 8
4 13 927.96 18 15.10 1529 416 2.79 / 86.23 2 10
5 13 392.16 18 15.23 862 236 3.02 / 86.46 2 12
6 13 101.44 18 15.28 499 137 3.16 / 86.60 2 12
7 8 0.08 165 15.25 340 856 4.02 / 87.45 2 15
Average= 3.98
(KJ/cycle)

Cycle 20 GMT 17/11/2024 14:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 27 15.20 484 199 0.20 / 79.59 2 4
2 7 2003.64 38 14.97 2809 1598 1.80 / 81.18 2 6
3 13 1360.32 18 15.05 2074 562 2.36 / 81.75 2 9
4 13 919.16 18 15.11 1513 412 2.77 / 82.16 2 10
5 13 376.60 18 15.23 844 231 3.00 / 82.39 2 11
6 13 118.52 18 15.28 491 135 3.14 / 82.52 2 11
7 13 15.40 18 15.29 349 96 3.23 / 82.62 2 9
8 8 0.12 165 15.24 325 817 4.05 / 83.44 2 13
Average= 3.97
(KJ/cycle)

Cycle 19 GMT 7/11/2024 18:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 27 15.18 467 191 0.19 / 75.68 2 3
2 7 2004.68 38 14.97 2820 1604 1.80 / 77.28 2 6
3 13 1351.40 18 15.05 2056 557 2.35 / 77.84 2 9
4 13 835.56 18 15.14 1421 387 2.74 / 78.23 2 11
5 13 346.28 18 15.24 796 218 2.96 / 78.45 2 12
6 13 96.64 18 15.29 471 130 3.09 / 78.57 2 12
7 8 0.00 165 15.26 323 813 3.90 / 79.39 2 15
Average= 3.97
(KJ/cycle)

Cycle 18 GMT 28/10/2024 23:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 27 15.19 469 192 0.19 / 71.45 2 4
2 3 972.60 -1 15.59 1 0 0.00 / 71.45 2 4
3 3 1016.88 1 15.29 1741 27 0.22 / 71.48 2 6
4 7 2011.40 39 14.98 2816 1645 1.86 / 73.12 2 6
5 13 1340.92 18 15.06 2025 549 2.41 / 73.67 2 9
6 13 821.28 18 15.14 1392 379 2.79 / 74.05 2 11
7 13 385.72 18 15.24 862 236 3.03 / 74.29 2 12
8 13 90.04 18 15.30 459 126 3.16 / 74.41 2 11
9 13 23.96 18 15.30 369 102 3.26 / 74.51 2 10
10 8 0.12 165 15.25 328 825 4.08 / 75.34 2 16
11 14 0.12 30 15.22 325 148 4.23 / 75.49 2 14
Average= 3.97
(KJ/cycle)

Cycle 17 GMT 19/10/2024 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 27 15.19 468 192 0.19 / 67.40 2 4
2 7 2005.00 38 14.97 2823 1606 1.80 / 69.00 2 8
3 13 1324.80 18 15.07 2020 548 2.35 / 69.55 2 8
4 13 896.96 18 15.13 1503 409 2.76 / 69.96 2 10
5 13 408.08 18 15.23 884 242 3.00 / 70.20 2 11
6 13 97.12 18 15.29 473 130 3.13 / 70.33 2 11
7 13 23.60 18 15.29 370 102 3.23 / 70.43 2 10
8 8 0.12 165 15.25 327 823 4.05 / 71.26 2 16
Average= 3.96
(KJ/cycle)

Cycle 16 GMT 9/10/2024 8:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 28 15.19 480 204 0.20 / 63.35 2 4
2 7 2010.08 39 14.98 2831 1654 1.86 / 65.00 2 6
3 13 1373.96 18 15.06 2071 561 2.42 / 65.56 2 8
4 13 804.92 18 15.15 1376 375 2.79 / 65.94 2 11
5 13 340.44 18 15.25 791 217 3.01 / 66.15 2 12
6 13 99.36 18 15.30 469 129 3.14 / 66.28 2 11
7 13 26.88 18 15.30 367 101 3.24 / 66.38 2 11
8 8 -0.04 165 15.26 326 821 4.06 / 67.20 2 15
Average= 3.95
(KJ/cycle)

Cycle 15 GMT 29/ 9/2024 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 28 15.21 480 204 0.20 / 59.28 2 3
2 7 2006.92 38 14.99 2817 1605 1.81 / 60.88 2 7
3 13 1359.32 18 15.07 2074 563 2.37 / 61.45 2 9
4 13 877.52 18 15.14 1485 405 2.78 / 61.85 2 9
5 13 391.36 18 15.24 864 237 3.01 / 62.09 2 11
6 13 87.04 18 15.30 463 128 3.14 / 62.22 2 11
7 13 21.52 18 15.30 364 100 3.24 / 62.32 2 11
8 8 0.04 165 15.26 328 826 4.07 / 63.14 2 16
Average= 3.95
(KJ/cycle)

Cycle 14 GMT 19/ 9/2024 17:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 28 15.21 473 201 0.20 / 55.31 2 3
2 7 2008.24 38 14.99 2816 1604 1.81 / 56.91 2 6
3 13 1332.00 18 15.07 2043 554 2.36 / 57.47 2 8
4 13 824.44 18 15.15 1422 388 2.75 / 57.86 2 10
5 13 360.40 18 15.25 828 227 2.97 / 58.08 2 11
6 13 111.72 18 15.30 508 140 3.11 / 58.22 2 12
7 8 0.12 165 15.26 338 851 3.97 / 59.07 2 14
Average= 3.94
(KJ/cycle)

Cycle 13 GMT 9/ 9/2024 21:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 28 15.20 471 200 0.20 / 51.18 2 3
2 3 1029.96 1 15.28 1750 27 0.23 / 51.20 2 7
3 7 2007.84 38 14.99 2814 1603 1.83 / 52.81 2 8
4 13 1398.12 18 15.07 2119 575 2.40 / 53.38 2 9
5 13 940.00 18 15.14 1549 422 2.83 / 53.80 2 10
6 13 431.04 18 15.25 904 248 3.08 / 54.05 2 12
7 13 78.48 18 15.32 449 124 3.20 / 54.17 2 11
8 13 17.52 18 15.32 364 100 3.30 / 54.28 2 10
9 8 0.00 165 15.26 331 833 4.13 / 55.11 2 18
Average= 3.94
(KJ/cycle)

Cycle 12 GMT 31/ 8/2024 2:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 27 15.21 474 195 0.19 / 47.04 2 3
2 3 1019.56 1 15.30 1720 26 0.22 / 47.06 2 6
3 7 2008.28 38 14.99 2814 1603 1.82 / 48.67 2 6
4 13 1403.08 18 15.07 2121 575 2.40 / 49.24 2 9
5 13 915.48 18 15.14 1524 415 2.81 / 49.66 2 10
6 13 387.64 18 15.25 863 237 3.05 / 49.89 2 11
7 13 96.24 18 15.31 486 134 3.19 / 50.03 2 11
8 13 21.08 18 15.31 378 104 3.29 / 50.13 2 10
9 8 0.04 165 15.26 335 843 4.13 / 50.98 2 15
Average= 3.92
(KJ/cycle)

Cycle 11 GMT 21/ 8/2024 7: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 27 15.22 462 190 0.19 / 42.99 2 3
2 7 2011.20 38 15.00 2825 1610 1.80 / 44.60 2 6
3 13 1314.96 18 15.08 2029 551 2.35 / 45.15 2 8
4 13 840.72 18 15.16 1439 393 2.74 / 45.54 2 10
5 13 366.72 18 15.26 839 230 2.97 / 45.77 2 11
6 13 106.04 18 15.31 490 135 3.11 / 45.91 2 11
7 13 11.52 18 15.32 355 98 3.21 / 46.01 2 10
8 8 0.04 165 15.27 332 836 4.04 / 46.84 2 15
Average= 3.90
(KJ/cycle)

Cycle 10 GMT 11/ 8/2024 11:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 27 15.23 464 191 0.19 / 39.06 2 3
2 3 1020.72 1 15.31 1739 27 0.22 / 39.08 2 5
3 7 2004.00 38 15.01 2798 1596 1.81 / 40.68 2 5
4 13 1382.48 18 15.09 2065 561 2.37 / 41.24 2 8
5 13 837.20 18 15.17 1422 388 2.76 / 41.63 2 10
6 13 355.16 18 15.27 808 222 2.98 / 41.85 2 10
7 13 105.60 18 15.31 476 131 3.12 / 41.98 2 11
8 8 0.08 165 15.28 324 817 3.93 / 42.80 2 14
Average= 3.89
(KJ/cycle)

Cycle 9 GMT 1/ 8/2024 16:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 26 15.24 472 187 0.19 / 34.38 2 3
2 3 1032.60 1 15.34 1756 27 0.21 / 34.40 2 7
3 7 2008.12 74 14.89 2790 3074 3.29 / 37.48 2 7
4 13 628.40 18 15.21 1153 316 3.60 / 37.79 2 11
5 13 143.88 18 15.32 533 147 3.75 / 37.94 2 12
6 13 25.52 18 15.34 372 103 3.85 / 38.04 2 11
7 8 0.00 165 15.28 327 824 4.68 / 38.87 2 17
Average= 3.89
(KJ/cycle)

Cycle 8 GMT 22/ 7/2024 19:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.24 31 15.21 485 229 0.23 / 29.66 2 3
2 3 914.08 -2 15.66 0 0 0.00 / 29.66 2 3
3 3 936.04 -1 15.69 0 0 0.00 / 29.66 2 3
4 7 2011.96 74 14.89 2826 3114 3.34 / 32.78 2 6
5 13 614.20 18 15.22 1138 312 3.65 / 33.09 2 11
6 13 171.96 18 15.32 570 157 3.81 / 33.25 2 11
7 13 31.00 18 15.34 382 105 3.92 / 33.35 2 10
8 8 0.12 165 15.29 332 838 4.75 / 34.19 2 12
Average= 3.80
(KJ/cycle)

Cycle 7 GMT 12/ 7/2024 21: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 26 15.22 456 180 0.18 / 24.93 2 3
2 3 1024.48 1 15.34 1714 26 0.21 / 24.95 2 6
3 7 1772.88 74 14.96 2534 2805 3.01 / 27.76 2 9
4 13 572.96 18 15.23 1075 295 3.31 / 28.05 2 10
5 13 120.08 18 15.33 479 132 3.44 / 28.18 2 11
6 13 17.88 18 15.34 345 95 3.53 / 28.28 2 9
7 8 0.00 165 15.29 314 792 4.33 / 29.07 2 17
8 14 0.00 75 15.24 317 362 4.69 / 29.43 2 20
Average= 3.68
(KJ/cycle)

Cycle 6 GMT 11/ 7/2024 20:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 27 15.23 455 187 0.19 / 20.63 2 3
2 3 969.72 -1 15.67 0 0 0.00 / 20.63 2 3
3 7 1782.28 74 14.96 2535 2806 2.99 / 23.43 2 9
4 13 505.84 18 15.25 996 273 3.27 / 23.71 2 10
5 13 124.60 18 15.32 501 138 3.41 / 23.84 2 11
6 13 18.20 18 15.33 352 97 3.50 / 23.94 2 10
7 8 0.16 165 15.29 319 805 4.31 / 24.75 2 14
Average= 3.54
(KJ/cycle)

Cycle 5 GMT 10/ 7/2024 19:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.16 27 15.25 489 201 0.20 / 16.31 2 3
2 7 1771.00 74 14.96 2520 2790 2.99 / 19.10 2 8
3 13 589.52 18 15.23 1091 299 3.29 / 19.40 2 11
4 13 130.88 18 15.33 502 139 3.43 / 19.54 2 11
5 13 17.48 18 15.34 350 97 3.53 / 19.63 2 9
6 8 0.08 165 15.29 319 805 4.33 / 20.44 2 17
Average= 3.41
(KJ/cycle)

Cycle 4 GMT 9/ 7/2024 18:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 27 15.25 444 183 0.18 / 12.41 2 3
2 7 1520.36 74 15.06 2225 2480 2.66 / 14.89 2 7
3 13 442.68 18 15.28 913 251 2.91 / 15.14 2 10
4 13 108.88 18 15.33 500 138 3.05 / 15.28 2 10
5 8 0.08 165 15.30 327 826 3.88 / 16.11 2 13
Average= 3.22
(KJ/cycle)

Cycle 3 GMT 8/ 7/2024 19: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.92 19 15.27 483 140 0.14 / 8.32 2 3
2 10 1010.92 5 15.25 1659 126 0.27 / 8.45 2 3
3 10 1061.32 3 15.26 1739 80 0.35 / 8.53 2 4
4 3 1081.36 2 15.33 1778 55 0.40 / 8.59 2 6
5 7 1525.48 74 15.05 2218 2470 2.87 / 11.06 2 7
6 13 506.24 18 15.27 982 270 3.14 / 11.33 2 10
7 13 109.64 18 15.34 463 128 3.27 / 11.45 2 10
8 8 0.04 165 15.31 308 778 4.05 / 12.23 2 15
Average= 3.06
(KJ/cycle)

Cycle 2 GMT 7/ 7/2024 19:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 33 15.29 442 223 0.22 / 4.71 2 4
2 3 766.40 -4 15.70 1 0 0.00 / 4.71 2 4
3 3 785.88 -4 15.71 1 0 0.00 / 4.71 2 4
4 7 1435.04 74 15.10 2112 2360 2.58 / 7.07 2 7
5 13 255.92 18 15.35 659 182 2.77 / 7.25 2 10
6 13 58.44 18 15.36 420 116 2.88 / 7.37 2 10
7 8 0.08 165 15.32 323 816 3.70 / 8.18 2 15
Average= 2.73
(KJ/cycle)

Cycle 1 GMT 6/ 7/2024 19: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 28 15.44 410 177 0.18 / 1.81 3 3
2 7 1007.20 74 15.23 1595 1798 1.97 / 3.61 2 10
3 13 18.84 18 15.43 337 94 2.07 / 3.70 2 10
4 8 0.04 165 15.37 309 784 2.85 / 4.49 2 18
Average= 2.24
(KJ/cycle)

Cycle 0 GMT 6/ 7/2024 8:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 82.80 28 15.61 395 173 0.17 / 0.17 3 3
2 7 100.84 74 15.58 411 474 0.65 / 0.65 2 3
3 8 0.24 240 15.54 265 988 1.63 / 1.63 2 12
Average= 1.63
(KJ/cycle)