SIO Argo Site:
Pump Diagnostics Page   



Serial= 7798 WMO= 4903559

Return

←PreviousNext→

Cycle 75 GMT 17/12/2024 23:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 23 15.18 409 143 0.14 / 250.94 6 7
2 7 2003.40 40 14.67 2856 1676 1.82 / 252.62 7 16
3 13 1270.16 20 14.78 1952 577 2.40 / 253.19 6 27
4 13 574.60 20 14.95 1065 318 2.71 / 253.51 6 35
5 13 110.36 20 15.10 433 131 2.84 / 253.64 6 26
6 13 58.16 20 15.11 355 107 2.95 / 253.75 6 25
7 8 0.04 244 15.08 264 971 3.92 / 254.72 6 132
Average= 3.35
(KJ/cycle)

Cycle 74 GMT 7/12/2024 17: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 23 15.13 408 142 0.14 / 248.56 6 6
2 3 966.76 -1 15.45 11 0 0.00 / 248.56 6 6
3 7 1026.60 41 15.06 1636 1010 1.15 / 249.57 6 31
4 13 105.80 20 15.25 430 131 1.28 / 249.70 6 26
5 13 34.36 20 15.26 324 99 1.38 / 249.80 6 25
6 8 -0.04 244 15.21 268 995 2.38 / 250.80 6 136
Average= 3.34
(KJ/cycle)

Cycle 73 GMT 2/12/2024 13:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 23 15.18 408 142 0.14 / 244.69 6 6
2 7 2009.88 40 14.70 2862 1683 1.83 / 246.37 6 20
3 13 1187.28 20 14.85 1843 547 2.37 / 246.92 6 28
4 13 599.24 20 14.98 1102 330 2.70 / 247.25 6 35
5 13 67.40 20 15.16 373 113 2.82 / 247.37 6 23
6 8 0.20 263 15.13 265 1054 3.87 / 248.42 6 138
Average= 3.36
(KJ/cycle)

Cycle 72 GMT 27/11/2024 5: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 22 15.13 405 135 0.13 / 242.32 6 6
2 3 1018.84 1 15.13 1658 25 0.16 / 242.35 6 21
3 7 1010.64 40 15.07 1620 977 1.14 / 243.33 21 32
4 13 103.68 20 15.26 424 129 1.27 / 243.45 6 25
5 13 32.44 20 15.26 324 99 1.36 / 243.55 6 23
6 8 0.12 246 15.22 266 996 2.36 / 244.55 6 138
Average= 3.35
(KJ/cycle)

Cycle 71 GMT 22/11/2024 1:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 23 15.19 413 144 0.14 / 238.41 6 6
2 7 2008.76 41 14.69 2867 1727 1.87 / 240.13 6 20
3 13 1171.64 20 14.85 1840 546 2.42 / 240.68 6 27
4 13 580.64 20 14.99 1082 324 2.74 / 241.00 6 33
5 13 87.72 20 15.15 408 124 2.87 / 241.13 6 27
6 8 0.12 261 15.13 269 1062 3.93 / 242.19 6 134
Average= 3.36
(KJ/cycle)

Cycle 70 GMT 16/11/2024 17:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 22 15.14 403 134 0.13 / 236.07 6 6
2 7 1013.84 40 15.07 1625 980 1.11 / 237.05 6 33
3 13 104.92 20 15.26 426 130 1.24 / 237.18 6 25
4 13 33.88 20 15.27 319 97 1.34 / 237.27 6 23
5 8 -0.04 246 15.22 264 988 2.33 / 238.26 7 138
Average= 3.36
(KJ/cycle)

Cycle 69 GMT 11/11/2024 13:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 23 15.19 410 143 0.14 / 232.15 6 6
2 7 2008.52 40 14.70 2876 1691 1.83 / 233.84 20 18
3 13 1279.20 20 14.83 1970 584 2.42 / 234.43 6 27
4 13 577.32 20 15.01 1071 322 2.74 / 234.75 6 32
5 13 102.72 20 15.16 418 127 2.87 / 234.87 6 24
6 13 26.80 20 15.17 305 93 2.96 / 234.97 6 23
7 8 0.16 244 15.14 261 964 3.92 / 235.93 6 144
Average= 3.37
(KJ/cycle)

Cycle 68 GMT 6/11/2024 5:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 24 15.14 381 138 0.14 / 229.78 6 6
2 3 958.52 -1 15.47 11 0 0.00 / 229.78 6 6
3 7 1008.28 41 15.07 1618 1000 1.14 / 230.78 6 28
4 13 126.32 20 15.26 451 138 1.28 / 230.92 6 24
5 13 68.08 20 15.26 368 112 1.39 / 231.03 6 25
6 8 -0.16 244 15.22 263 977 2.36 / 232.01 6 129
Average= 3.36
(KJ/cycle)

Cycle 67 GMT 1/11/2024 2: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 24 15.20 392 143 0.14 / 225.89 6 7
2 3 959.48 -1 15.48 11 0 0.00 / 225.89 6 7
3 7 2007.84 40 14.70 2867 1686 1.83 / 227.58 7 16
4 13 1176.24 20 14.86 1833 545 2.37 / 228.12 6 28
5 13 593.32 20 15.00 1090 327 2.70 / 228.45 6 32
6 13 120.20 20 15.16 441 134 2.83 / 228.58 6 23
7 13 32.68 20 15.18 312 95 2.93 / 228.68 6 20
8 8 0.00 244 15.14 261 964 3.89 / 229.64 6 146
Average= 3.38
(KJ/cycle)

Cycle 66 GMT 26/10/2024 17:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.04 23 15.15 410 143 0.14 / 223.55 6 6
2 7 1005.92 40 15.09 1608 971 1.11 / 224.52 6 29
3 13 139.88 20 15.26 468 143 1.26 / 224.67 6 22
4 13 78.80 20 15.26 379 116 1.37 / 224.78 6 19
5 8 0.08 246 15.23 258 967 2.34 / 225.75 6 137
Average= 3.37
(KJ/cycle)

Cycle 65 GMT 21/10/2024 14: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 23 15.21 407 142 0.14 / 219.62 6 6
2 3 1050.08 1 15.14 1680 25 0.17 / 219.65 6 24
3 7 2003.64 40 14.71 2857 1681 1.85 / 221.33 24 18
4 13 1184.92 20 14.86 1851 550 2.40 / 221.88 6 27
5 13 604.48 20 15.01 1107 332 2.73 / 222.21 6 31
6 13 143.28 20 15.16 471 143 2.87 / 222.35 6 23
7 13 75.28 20 15.17 371 113 2.99 / 222.46 6 21
8 8 0.00 244 15.15 256 946 3.93 / 223.41 6 137
Average= 3.39
(KJ/cycle)

Cycle 64 GMT 16/10/2024 5:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 24 15.15 385 140 0.14 / 217.30 6 6
2 7 988.28 40 15.11 1585 958 1.10 / 218.26 6 29
3 13 144.08 20 15.27 473 144 1.24 / 218.40 6 19
4 13 81.76 20 15.27 378 115 1.36 / 218.52 6 19
5 8 0.16 246 15.24 256 960 2.32 / 219.48 6 135
Average= 3.38
(KJ/cycle)

Cycle 63 GMT 11/10/2024 2:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 23 15.21 385 135 0.13 / 213.40 6 6
2 7 2008.60 40 14.71 2871 1689 1.82 / 215.09 6 20
3 13 1176.36 20 14.87 1839 547 2.37 / 215.64 6 27
4 13 604.76 20 15.01 1111 334 2.70 / 215.97 6 31
5 13 128.08 20 15.16 454 138 2.84 / 216.11 6 22
6 13 35.04 20 15.19 314 95 2.94 / 216.20 6 20
7 8 0.08 244 15.15 259 957 3.89 / 217.16 6 140
Average= 3.39
(KJ/cycle)

Cycle 62 GMT 5/10/2024 17:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.64 24 15.16 413 150 0.15 / 211.06 6 7
2 7 1012.52 40 15.09 1621 978 1.13 / 212.04 7 31
3 13 160.96 20 15.27 491 150 1.28 / 212.19 6 22
4 13 89.08 20 15.27 386 118 1.40 / 212.31 6 20
5 8 0.08 246 15.24 256 960 2.36 / 213.27 6 133
Average= 3.39
(KJ/cycle)

Cycle 61 GMT 30/ 9/2024 14:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 23 15.22 387 135 0.14 / 207.07 6 6
2 7 2007.08 41 14.71 2869 1730 1.87 / 208.80 6 21
3 13 1259.80 20 14.85 1947 578 2.44 / 209.38 6 29
4 13 556.60 20 15.03 1045 314 2.76 / 209.69 6 31
5 13 183.16 20 15.15 529 160 2.92 / 209.85 6 27
6 13 44.96 20 15.18 334 101 3.02 / 209.95 6 22
7 8 0.00 242 15.15 261 957 3.98 / 210.91 6 139
Average= 3.40
(KJ/cycle)

Cycle 60 GMT 25/ 9/2024 5:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 23 15.15 412 144 0.14 / 204.69 6 6
2 3 1025.68 1 15.16 1647 25 0.17 / 204.72 6 23
3 7 1008.32 40 15.09 1615 975 1.14 / 205.69 23 31
4 13 159.72 20 15.26 501 153 1.30 / 205.85 6 23
5 13 86.16 20 15.27 393 120 1.42 / 205.97 6 21
6 8 0.16 246 15.24 258 967 2.38 / 206.93 6 138
Average= 3.39
(KJ/cycle)

Cycle 59 GMT 20/ 9/2024 2:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 23 15.22 394 138 0.14 / 200.79 6 6
2 7 2008.44 40 14.72 2863 1686 1.82 / 202.48 6 22
3 13 1186.88 20 14.87 1861 553 2.38 / 203.03 6 28
4 13 598.56 20 15.02 1098 330 2.71 / 203.36 6 30
5 13 134.92 20 15.17 457 139 2.85 / 203.50 6 23
6 13 32.28 20 15.20 309 94 2.94 / 203.59 6 20
7 8 0.16 244 15.16 259 958 3.90 / 204.55 6 146
Average= 3.41
(KJ/cycle)

Cycle 58 GMT 14/ 9/2024 17:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 22 15.16 406 135 0.14 / 198.40 6 6
2 3 1032.20 1 15.13 1693 26 0.16 / 198.43 6 24
3 7 1014.24 40 15.09 1624 980 1.14 / 199.41 24 30
4 13 156.40 20 15.27 492 150 1.29 / 199.56 6 22
5 13 86.76 20 15.28 388 119 1.41 / 199.68 6 19
6 8 0.08 248 15.25 258 976 2.39 / 200.65 6 145
Average= 3.40
(KJ/cycle)

Cycle 57 GMT 9/ 9/2024 14:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 24 15.22 394 144 0.14 / 194.49 6 6
2 7 2007.76 40 14.72 2873 1692 1.84 / 196.18 6 19
3 13 1175.68 20 14.88 1837 547 2.38 / 196.73 6 25
4 13 595.80 20 15.03 1097 330 2.71 / 197.06 6 34
5 13 113.56 20 15.18 440 134 2.85 / 197.19 6 24
6 13 29.48 20 15.20 313 95 2.94 / 197.29 6 21
7 8 0.04 244 15.16 264 977 3.92 / 198.27 6 144
Average= 3.42
(KJ/cycle)

Cycle 56 GMT 4/ 9/2024 5:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 24 15.16 395 144 0.14 / 192.13 6 7
2 3 955.64 -1 15.48 11 0 0.00 / 192.13 6 7
3 7 1007.08 40 15.10 1615 975 1.12 / 193.11 7 29
4 13 146.96 20 15.28 483 148 1.27 / 193.26 6 21
5 13 79.04 20 15.28 382 117 1.38 / 193.37 6 21
6 8 0.04 246 15.25 260 975 2.36 / 194.35 6 140
Average= 3.41
(KJ/cycle)

Cycle 55 GMT 30/ 8/2024 2: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 24 15.23 386 141 0.14 / 188.13 6 6
2 7 2007.84 40 14.72 2870 1690 1.83 / 189.82 6 20
3 13 1279.32 20 14.86 1968 585 2.42 / 190.40 6 28
4 13 675.12 20 15.00 1208 362 2.78 / 190.77 6 34
5 13 161.96 20 15.16 507 154 2.93 / 190.92 6 26
6 13 43.20 20 15.20 331 101 3.03 / 191.02 6 21
7 8 0.00 242 15.17 264 969 4.00 / 191.99 6 135
Average= 3.43
(KJ/cycle)

Cycle 54 GMT 24/ 8/2024 17:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 23 15.18 410 143 0.14 / 185.77 6 6
2 7 1001.96 40 15.11 1615 976 1.12 / 186.74 21 29
3 13 190.64 20 15.28 548 167 1.29 / 186.91 6 25
4 13 53.60 20 15.29 348 106 1.39 / 187.02 6 20
5 8 0.08 246 15.26 259 972 2.37 / 187.99 6 143
Average= 3.42
(KJ/cycle)

Cycle 53 GMT 19/ 8/2024 14:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 25 15.23 397 151 0.15 / 181.80 6 6
2 3 956.56 -1 15.50 11 0 0.00 / 181.80 6 6
3 7 2009.04 41 14.72 2872 1733 1.88 / 183.53 6 20
4 13 1269.72 20 14.86 1966 584 2.47 / 184.12 6 28
5 13 547.92 20 15.05 1029 310 2.78 / 184.43 6 31
6 13 127.60 20 15.19 452 137 2.92 / 184.56 6 21
7 13 33.24 20 15.21 315 96 3.01 / 184.66 6 18
8 8 0.12 244 15.18 260 963 3.97 / 185.62 6 145
Average= 3.44
(KJ/cycle)

Cycle 52 GMT 14/ 8/2024 5:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 24 15.18 390 142 0.14 / 179.48 6 6
2 7 967.68 40 15.13 1562 945 1.09 / 180.43 6 29
3 13 169.44 20 15.29 518 158 1.25 / 180.58 6 22
4 13 45.04 20 15.31 333 102 1.35 / 180.69 6 20
5 8 0.04 242 15.27 260 961 2.31 / 181.65 6 134
Average= 3.43
(KJ/cycle)

Cycle 51 GMT 9/ 8/2024 2:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.96 25 15.23 417 159 0.16 / 175.58 6 6
2 7 2008.44 40 14.73 2874 1693 1.85 / 177.28 6 22
3 13 1183.28 20 14.90 1842 549 2.40 / 177.83 6 26
4 13 600.32 20 15.04 1103 332 2.73 / 178.16 6 32
5 13 138.92 20 15.19 465 141 2.87 / 178.30 6 23
6 13 34.32 20 15.22 313 95 2.97 / 178.40 6 20
7 8 0.04 240 15.18 259 944 3.91 / 179.34 6 131
Average= 3.45
(KJ/cycle)

Cycle 50 GMT 3/ 8/2024 17:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 24 15.18 417 152 0.15 / 173.19 6 6
2 7 999.96 41 15.12 1605 995 1.15 / 174.18 20 26
3 13 190.68 20 15.29 546 167 1.31 / 174.35 6 25
4 13 49.60 20 15.30 338 103 1.42 / 174.45 6 20
5 8 0.00 244 15.26 262 976 2.39 / 175.43 6 133
Average= 3.44
(KJ/cycle)

Cycle 49 GMT 29/ 7/2024 14:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 24 15.23 413 151 0.15 / 169.24 6 6
2 3 1026.80 1 15.18 1644 25 0.18 / 169.27 6 22
3 7 2006.28 41 14.73 2869 1733 1.91 / 171.00 22 21
4 13 1170.84 20 14.90 1837 547 2.46 / 171.55 6 29
5 13 486.12 20 15.09 951 287 2.74 / 171.83 6 29
6 13 152.32 20 15.19 484 147 2.89 / 171.98 6 22
7 13 36.92 20 15.22 317 96 2.99 / 172.08 6 19
8 8 0.24 244 15.18 258 956 3.94 / 173.03 6 146
Average= 3.46
(KJ/cycle)

Cycle 48 GMT 24/ 7/2024 5:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 23 15.18 392 137 0.14 / 166.83 6 6
2 3 1031.60 1 15.16 1654 25 0.16 / 166.85 6 22
3 7 1022.36 40 15.12 1637 990 1.15 / 167.84 22 25
4 13 169.72 20 15.29 505 154 1.31 / 168.00 6 21
5 13 88.96 20 15.30 389 119 1.43 / 168.12 6 18
6 8 0.08 246 15.27 259 973 2.40 / 169.09 6 133
Average= 3.45
(KJ/cycle)

Cycle 47 GMT 19/ 7/2024 2:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 24 15.23 393 144 0.14 / 162.92 6 6
2 7 2007.08 40 14.74 2871 1693 1.84 / 164.61 22 19
3 13 1183.32 20 14.91 1851 552 2.39 / 165.16 6 28
4 13 603.36 20 15.05 1106 333 2.72 / 165.50 6 31
5 13 149.00 20 15.20 477 145 2.87 / 165.64 6 21
6 13 35.64 20 15.22 313 95 2.96 / 165.74 6 18
7 8 0.08 242 15.19 260 956 3.92 / 166.69 6 132
Average= 3.47
(KJ/cycle)

Cycle 46 GMT 13/ 7/2024 17:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 24 15.19 392 143 0.14 / 160.51 6 6
2 3 951.56 -1 15.50 11 0 0.00 / 160.51 6 6
3 7 1009.56 41 15.12 1621 1005 1.15 / 161.52 6 29
4 13 190.92 20 15.29 551 168 1.32 / 161.69 6 25
5 13 48.92 20 15.31 342 105 1.42 / 161.79 6 21
6 8 0.04 244 15.27 264 984 2.40 / 162.78 6 140
Average= 3.46
(KJ/cycle)

Cycle 45 GMT 8/ 7/2024 14:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 23 15.18 416 145 0.15 / 156.56 6 6
2 3 1045.88 1 15.16 1679 25 0.17 / 156.59 6 24
3 7 2003.96 41 14.75 2864 1732 1.90 / 158.32 24 18
4 13 1156.60 20 14.92 1816 542 2.44 / 158.86 6 28
5 13 574.36 20 15.06 1070 322 2.77 / 159.18 6 31
6 13 130.96 20 15.20 460 140 2.91 / 159.32 6 21
7 13 16.44 20 15.23 291 89 3.00 / 159.41 6 18
8 8 0.04 240 15.19 263 959 3.95 / 160.37 6 133
Average= 3.49
(KJ/cycle)

Cycle 44 GMT 3/ 7/2024 5:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 24 15.18 398 145 0.14 / 152.61 6 6
2 3 941.04 -1 15.50 10 0 0.00 / 152.61 6 6
3 7 2006.40 40 14.75 2867 1692 1.84 / 154.30 6 20
4 13 1265.72 20 14.88 1960 583 2.42 / 154.89 6 26
5 13 565.40 20 15.06 1062 320 2.74 / 155.21 6 31
6 13 192.28 20 15.18 548 166 2.91 / 155.37 6 27
7 8 0.12 261 15.19 263 1043 3.95 / 156.42 6 133
Average= 3.48
(KJ/cycle)

Cycle 43 GMT 22/ 6/2024 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 24 15.19 419 153 0.15 / 148.62 6 6
2 3 1022.80 1 15.18 1644 25 0.18 / 148.64 6 22
3 7 2003.20 40 14.75 2859 1687 1.86 / 150.33 22 20
4 13 1269.00 20 14.89 1954 582 2.45 / 150.91 6 27
5 13 662.00 20 15.03 1182 355 2.80 / 151.27 6 33
6 13 119.92 20 15.20 444 135 2.94 / 151.40 6 22
7 8 0.12 263 15.19 267 1067 4.00 / 152.47 6 154
Average= 3.47
(KJ/cycle)

Cycle 42 GMT 12/ 6/2024 16:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 24 15.19 415 151 0.15 / 144.68 6 6
2 7 2009.64 41 14.75 2877 1740 1.89 / 146.42 6 19
3 13 1154.32 20 14.91 1820 543 2.43 / 146.96 6 29
4 13 571.52 20 15.06 1068 322 2.76 / 147.28 6 30
5 13 124.08 20 15.20 449 136 2.89 / 147.42 6 21
6 8 0.16 261 15.19 264 1047 3.94 / 148.46 6 136
Average= 3.45
(KJ/cycle)

Cycle 41 GMT 2/ 6/2024 9:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 23 15.19 421 147 0.15 / 140.73 6 6
2 3 1023.72 1 15.19 1659 25 0.17 / 140.75 6 23
3 7 2003.64 40 14.76 2865 1691 1.86 / 142.44 23 21
4 13 1171.40 20 14.92 1843 550 2.41 / 142.99 6 29
5 13 593.96 20 15.06 1103 332 2.75 / 143.32 6 29
6 13 132.68 20 15.21 458 139 2.89 / 143.46 6 22
7 13 30.08 20 15.23 311 95 2.98 / 143.56 6 20
8 8 0.04 242 15.20 263 967 3.95 / 144.53 6 144
Average= 3.44
(KJ/cycle)

Cycle 40 GMT 23/ 5/2024 3:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 23 15.19 420 147 0.15 / 136.81 6 6
2 7 2002.36 40 14.77 2868 1694 1.84 / 138.50 6 21
3 13 1170.92 20 14.92 1836 548 2.39 / 139.05 6 29
4 13 589.20 20 15.07 1090 329 2.72 / 139.38 6 33
5 13 120.08 20 15.21 445 135 2.85 / 139.51 6 22
6 8 0.16 263 15.20 266 1063 3.92 / 140.58 6 149
Average= 3.43
(KJ/cycle)

Cycle 39 GMT 12/ 5/2024 20:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 23 15.20 414 145 0.14 / 132.87 6 6
2 3 1023.80 1 15.18 1672 25 0.17 / 132.89 6 23
3 7 2009.40 40 14.77 2873 1697 1.87 / 134.59 23 23
4 13 1169.28 20 14.93 1834 548 2.42 / 135.14 6 29
5 13 588.08 20 15.07 1086 327 2.74 / 135.47 6 34
6 13 119.00 20 15.22 446 136 2.88 / 135.60 6 24
7 8 0.12 261 15.20 267 1059 3.94 / 136.66 6 140
Average= 3.42
(KJ/cycle)

Cycle 38 GMT 2/ 5/2024 13:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 24 15.20 392 143 0.14 / 128.97 6 6
2 3 955.84 -1 15.51 11 0 0.00 / 128.97 6 6
3 7 2006.20 40 14.76 2884 1703 1.85 / 130.67 6 22
4 13 1166.32 20 14.93 1841 550 2.40 / 131.22 6 30
5 13 580.40 20 15.07 1079 325 2.72 / 131.55 6 37
6 13 119.92 20 15.22 450 137 2.86 / 131.68 6 24
7 8 0.08 259 15.21 264 1040 3.90 / 132.72 6 137
Average= 3.40
(KJ/cycle)

Cycle 37 GMT 22/ 4/2024 7: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 24 15.20 408 149 0.15 / 125.05 6 6
2 7 2009.64 40 14.77 2883 1703 1.85 / 126.75 6 20
3 13 1181.32 20 14.93 1851 553 2.40 / 127.30 6 29
4 13 594.00 20 15.07 1094 330 2.73 / 127.63 6 32
5 13 131.68 20 15.22 463 141 2.88 / 127.77 6 23
6 8 0.04 261 15.21 265 1052 3.93 / 128.83 6 141
Average= 3.39
(KJ/cycle)

Cycle 36 GMT 12/ 4/2024 0:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 24 15.21 408 149 0.15 / 121.12 6 7
2 7 2010.20 41 14.77 2865 1735 1.88 / 122.85 7 21
3 13 1170.04 20 14.94 1839 549 2.43 / 123.40 6 29
4 13 576.56 20 15.08 1074 324 2.76 / 123.72 6 35
5 13 101.00 20 15.23 418 127 2.88 / 123.85 6 24
6 8 -0.12 259 15.21 266 1048 3.93 / 124.90 6 143
Average= 3.38
(KJ/cycle)

Cycle 35 GMT 1/ 4/2024 17:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 24 15.21 404 147 0.15 / 117.19 6 7
2 7 2008.92 40 14.78 2873 1699 1.85 / 118.89 7 16
3 13 1260.08 20 14.92 1945 580 2.43 / 119.47 6 29
4 13 554.92 20 15.10 1046 316 2.74 / 119.78 6 32
5 13 116.48 20 15.23 442 135 2.88 / 119.92 6 20
6 8 0.16 261 15.22 264 1049 3.93 / 120.97 6 141
Average= 3.36
(KJ/cycle)

Cycle 34 GMT 22/ 3/2024 10:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 25 15.22 410 156 0.16 / 113.27 6 6
2 7 2009.84 40 14.78 2885 1706 1.86 / 114.97 6 22
3 13 1166.44 20 14.95 1832 548 2.41 / 115.52 6 26
4 13 691.12 20 15.05 1221 368 2.78 / 115.89 6 31
5 13 113.68 20 15.23 426 130 2.91 / 116.02 6 22
6 8 0.04 259 15.22 260 1025 3.93 / 117.04 6 135
Average= 3.34
(KJ/cycle)

Cycle 33 GMT 12/ 3/2024 4:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 24 15.22 413 151 0.15 / 109.31 6 6
2 7 2002.88 40 14.79 2868 1697 1.85 / 111.01 22 19
3 13 1259.08 20 14.93 1946 581 2.43 / 111.59 6 24
4 13 653.16 20 15.07 1167 352 2.78 / 111.94 6 30
5 13 144.04 20 15.23 477 145 2.93 / 112.09 6 24
6 8 0.12 259 15.23 259 1022 3.95 / 113.11 6 135
Average= 3.33
(KJ/cycle)

Cycle 32 GMT 1/ 3/2024 22: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 24 15.23 405 148 0.15 / 105.43 6 7
2 7 2010.48 40 14.79 2872 1699 1.85 / 107.13 7 20
3 13 1172.84 20 14.96 1835 549 2.40 / 107.68 6 25
4 13 594.84 20 15.10 1083 327 2.72 / 108.01 6 29
5 13 141.24 20 15.24 459 140 2.86 / 108.15 6 22
6 8 0.00 261 15.23 255 1014 3.88 / 109.16 6 139
Average= 3.31
(KJ/cycle)

Cycle 31 GMT 20/ 2/2024 15:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 24 15.22 411 150 0.15 / 101.52 6 6
2 7 2009.92 40 14.80 2871 1700 1.85 / 103.22 6 18
3 13 1271.00 20 14.93 1960 585 2.44 / 103.81 6 29
4 13 568.48 20 15.11 1050 317 2.75 / 104.12 6 28
5 13 127.40 20 15.25 445 136 2.89 / 104.26 6 24
6 8 0.20 261 15.23 258 1026 3.91 / 105.29 6 135
Average= 3.29
(KJ/cycle)

Cycle 30 GMT 10/ 2/2024 8:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 24 15.23 411 150 0.15 / 97.61 6 6
2 7 2007.32 40 14.80 2873 1701 1.85 / 99.31 6 20
3 13 1259.96 20 14.94 1949 582 2.43 / 99.89 6 30
4 13 560.84 20 15.12 1047 317 2.75 / 100.21 6 31
5 13 113.12 20 15.25 431 131 2.88 / 100.34 6 24
6 8 0.20 257 15.24 264 1034 3.92 / 101.37 6 133
Average= 3.27
(KJ/cycle)

Cycle 29 GMT 31/ 1/2024 1:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 24 15.22 416 152 0.15 / 93.68 6 6
2 7 2005.32 40 14.80 2864 1695 1.85 / 95.37 6 20
3 13 1277.48 20 14.94 1965 587 2.43 / 95.96 6 29
4 13 567.20 20 15.11 1057 319 2.75 / 96.28 6 32
5 13 137.04 20 15.25 463 141 2.90 / 96.42 6 22
6 8 0.20 263 15.24 259 1038 3.93 / 97.46 6 141
Average= 3.25
(KJ/cycle)

Cycle 28 GMT 20/ 1/2024 19: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.36 24 15.23 415 152 0.15 / 89.79 6 6
2 7 2002.32 40 14.81 2855 1691 1.84 / 91.48 6 21
3 13 1156.44 20 14.97 1815 543 2.39 / 92.02 6 29
4 13 568.76 20 15.11 1061 321 2.71 / 92.34 6 33
5 13 106.52 20 15.25 429 131 2.84 / 92.47 6 23
6 8 0.08 261 15.24 264 1050 3.89 / 93.52 6 133
Average= 3.22
(KJ/cycle)

Cycle 27 GMT 10/ 1/2024 12:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 24 15.23 409 149 0.15 / 85.85 6 6
2 3 1027.64 1 15.20 1676 25 0.17 / 85.88 6 22
3 7 2006.56 40 14.81 2877 1704 1.88 / 87.58 22 20
4 13 1161.36 20 14.97 1834 549 2.43 / 88.13 6 28
5 13 571.88 20 15.11 1070 323 2.75 / 88.45 6 32
6 13 103.80 20 15.26 423 129 2.88 / 88.58 6 23
7 8 0.08 261 15.24 265 1054 3.93 / 89.64 6 129
Average= 3.20
(KJ/cycle)

Cycle 26 GMT 31/12/2023 5:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 24 15.24 388 142 0.14 / 81.92 6 6
2 7 2008.60 40 14.81 2872 1701 1.84 / 83.62 6 19
3 13 1178.92 20 14.98 1839 551 2.39 / 84.17 6 29
4 13 591.48 20 15.11 1099 332 2.73 / 84.50 6 31
5 13 108.68 20 15.26 430 131 2.86 / 84.63 6 23
6 8 0.16 261 15.24 268 1066 3.92 / 85.70 6 140
Average= 3.17
(KJ/cycle)

Cycle 25 GMT 20/12/2023 23: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 24 15.24 390 143 0.14 / 78.06 6 6
2 7 2006.36 40 14.81 2880 1706 1.85 / 79.76 6 19
3 13 1167.20 20 14.98 1845 553 2.40 / 80.32 6 29
4 13 485.28 20 15.15 954 289 2.69 / 80.61 6 32
5 13 118.56 20 15.26 448 137 2.83 / 80.74 6 26
6 8 0.08 259 15.25 262 1035 3.86 / 81.78 6 148
Average= 3.15
(KJ/cycle)

Cycle 24 GMT 10/12/2023 16:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 23 15.23 402 141 0.14 / 74.11 6 6
2 7 2006.92 40 14.82 2878 1706 1.85 / 75.82 6 21
3 13 1257.40 20 14.96 1959 586 2.43 / 76.41 6 29
4 13 550.96 20 15.13 1049 317 2.75 / 76.72 6 33
5 13 113.60 20 15.26 445 136 2.89 / 76.86 6 22
6 13 29.16 20 15.28 313 96 2.98 / 76.96 6 22
7 8 0.12 242 15.25 260 960 3.94 / 77.91 6 140
Average= 3.12
(KJ/cycle)

Cycle 23 GMT 30/11/2023 9:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 23 15.30 395 139 0.14 / 70.19 6 6
2 7 2004.56 40 14.82 2876 1705 1.84 / 71.90 6 22
3 13 1158.80 20 14.98 1825 547 2.39 / 72.44 6 30
4 13 567.80 20 15.12 1062 321 2.71 / 72.76 6 33
5 13 91.28 20 15.26 408 125 2.84 / 72.89 6 25
6 13 49.08 20 15.27 345 105 2.94 / 72.99 6 25
7 8 0.08 240 15.24 268 980 3.92 / 73.97 6 140
Average= 3.08
(KJ/cycle)

Cycle 22 GMT 20/11/2023 2:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 24 15.23 402 147 0.15 / 67.83 6 6
2 7 997.36 40 15.19 1619 984 1.13 / 68.82 6 31
3 13 117.28 20 15.38 448 138 1.27 / 68.95 6 22
4 13 37.12 20 15.39 327 101 1.37 / 69.06 6 23
5 8 0.08 244 15.34 266 996 2.36 / 70.05 6 138
Average= 3.05
(KJ/cycle)

Cycle 21 GMT 14/11/2023 23:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 25 15.31 401 153 0.15 / 64.00 6 6
2 3 949.52 -1 15.56 11 0 0.00 / 64.00 6 6
3 7 2005.64 40 14.83 2869 1702 1.86 / 65.71 6 20
4 13 1048.20 20 15.01 1684 506 2.36 / 66.21 6 30
5 13 480.08 20 15.15 950 288 2.65 / 66.50 6 33
6 13 108.16 20 15.26 433 132 2.78 / 66.63 6 25
7 8 0.04 257 15.25 269 1054 3.84 / 67.69 6 136
Average= 3.08
(KJ/cycle)

Cycle 20 GMT 9/11/2023 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 25 15.24 394 150 0.15 / 61.67 6 6
2 7 974.76 40 15.21 1582 962 1.11 / 62.63 6 30
3 13 102.76 20 15.40 416 128 1.24 / 62.76 6 23
4 13 56.76 20 15.39 351 108 1.35 / 62.87 6 23
5 8 0.04 240 15.35 267 984 2.33 / 63.85 6 140
Average= 3.04
(KJ/cycle)

Cycle 19 GMT 4/11/2023 11:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 24 15.32 409 150 0.15 / 57.73 6 6
2 3 1024.84 1 15.25 1657 25 0.18 / 57.75 6 24
3 7 2006.44 40 14.84 2876 1707 1.88 / 59.46 24 21
4 13 1155.68 20 15.00 1818 545 2.43 / 60.00 6 30
5 13 574.04 20 15.13 1069 323 2.75 / 60.33 6 32
6 13 103.84 20 15.27 426 130 2.88 / 60.46 6 25
7 13 29.60 20 15.28 315 96 2.98 / 60.55 6 23
8 8 0.08 238 15.25 266 965 3.94 / 61.52 6 135
Average= 3.08
(KJ/cycle)

Cycle 18 GMT 30/10/2023 3:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 24 15.25 407 149 0.15 / 55.38 6 6
2 7 1002.40 40 15.20 1610 979 1.13 / 56.36 21 31
3 13 113.00 20 15.39 427 131 1.26 / 56.49 6 22
4 13 59.40 20 15.39 350 108 1.37 / 56.59 6 22
5 8 0.00 242 15.35 264 981 2.35 / 57.58 6 133
Average= 3.03
(KJ/cycle)

Cycle 17 GMT 24/10/2023 23:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 24 15.31 397 146 0.15 / 51.51 6 6
2 7 2003.04 40 14.84 2870 1704 1.85 / 53.21 6 21
3 13 1159.12 20 15.00 1819 546 2.40 / 53.76 6 30
4 13 478.24 20 15.17 944 286 2.68 / 54.04 6 32
5 13 74.52 20 15.28 382 117 2.80 / 54.16 6 22
6 13 22.92 20 15.29 306 94 2.89 / 54.25 6 22
7 8 0.08 240 15.25 266 974 3.87 / 55.23 6 135
Average= 3.07
(KJ/cycle)

Cycle 16 GMT 19/10/2023 15:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 25 15.25 393 150 0.15 / 49.14 6 6
2 7 995.96 40 15.21 1610 980 1.13 / 50.12 6 29
3 13 120.80 20 15.39 446 137 1.27 / 50.25 6 22
4 13 65.32 20 15.39 359 111 1.38 / 50.37 6 22
5 8 0.08 244 15.36 266 997 2.37 / 51.36 6 140
Average= 3.02
(KJ/cycle)

Cycle 15 GMT 14/10/2023 11:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 24 15.32 391 144 0.14 / 45.25 6 6
2 7 2005.48 40 14.84 2874 1706 1.85 / 46.95 6 20
3 13 1166.00 20 15.00 1833 550 2.40 / 47.50 6 29
4 13 474.68 20 15.18 934 284 2.68 / 47.79 6 30
5 13 115.28 20 15.28 438 134 2.82 / 47.92 6 22
6 13 29.68 20 15.30 315 96 2.91 / 48.02 6 20
7 8 0.04 240 15.26 265 971 3.88 / 48.99 6 138
Average= 3.06
(KJ/cycle)

Cycle 14 GMT 9/10/2023 3:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 25 15.26 392 150 0.15 / 42.89 6 6
2 7 996.64 41 15.21 1601 998 1.15 / 43.89 6 30
3 13 127.16 20 15.40 452 139 1.29 / 44.03 6 20
4 13 69.28 20 15.40 365 112 1.40 / 44.14 6 20
5 8 0.16 242 15.36 260 966 2.37 / 45.10 6 137
Average= 3.01
(KJ/cycle)

Cycle 13 GMT 3/10/2023 23:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 24 15.33 389 143 0.14 / 38.96 6 6
2 7 2007.64 40 14.85 2872 1706 1.85 / 40.67 6 18
3 13 1265.28 20 14.98 1954 585 2.43 / 41.25 6 27
4 13 546.72 20 15.15 1027 311 2.75 / 41.57 6 31
5 13 124.48 20 15.28 443 135 2.88 / 41.70 6 20
6 13 34.04 20 15.30 312 95 2.98 / 41.80 6 18
7 8 0.04 240 15.27 257 942 3.92 / 42.74 6 137
Average= 3.05
(KJ/cycle)

Cycle 12 GMT 28/ 9/2023 15:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 25 15.26 389 148 0.15 / 36.61 6 6
2 7 997.04 40 15.23 1599 974 1.12 / 37.58 6 29
3 13 185.96 20 15.39 535 165 1.29 / 37.75 6 24
4 13 53.60 20 15.41 342 105 1.39 / 37.85 6 20
5 8 0.12 242 15.37 260 967 2.36 / 38.82 6 131
Average= 2.99
(KJ/cycle)

Cycle 11 GMT 23/ 9/2023 12: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 25 15.33 398 153 0.15 / 32.75 6 6
2 7 2003.16 40 14.86 2869 1705 1.86 / 34.45 6 20
3 13 1152.52 20 15.01 1823 547 2.41 / 35.00 6 28
4 13 466.32 20 15.19 917 279 2.68 / 35.28 6 29
5 13 132.24 20 15.28 459 140 2.82 / 35.42 6 21
6 13 33.12 20 15.30 311 95 2.92 / 35.51 6 19
7 8 0.08 240 15.27 258 946 3.86 / 36.46 6 139
Average= 3.04
(KJ/cycle)

Cycle 10 GMT 18/ 9/2023 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 25 15.26 392 150 0.15 / 30.36 6 6
2 7 1001.16 40 15.23 1615 984 1.13 / 31.34 20 29
3 13 152.36 20 15.40 490 151 1.28 / 31.50 6 19
4 13 81.04 20 15.40 382 118 1.40 / 31.61 6 19
5 8 0.12 244 15.37 262 983 2.38 / 32.60 6 147
Average= 2.96
(KJ/cycle)

Cycle 9 GMT 12/ 9/2023 23:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 24 15.34 386 142 0.14 / 26.50 6 6
2 7 2003.56 40 14.87 2867 1705 1.85 / 28.21 20 19
3 13 1160.44 20 15.02 1824 548 2.40 / 28.76 6 28
4 13 473.04 20 15.19 932 283 2.68 / 29.04 6 30
5 13 133.16 20 15.28 459 140 2.82 / 29.18 6 22
6 13 16.76 20 15.31 288 88 2.91 / 29.27 6 19
7 8 0.04 240 15.27 257 942 3.85 / 30.21 6 146
Average= 3.02
(KJ/cycle)

Cycle 8 GMT 7/ 9/2023 15:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 24 15.27 384 141 0.14 / 24.14 6 6
2 7 1005.76 40 15.23 1617 985 1.13 / 25.13 19 29
3 13 149.64 20 15.40 485 149 1.28 / 25.28 6 20
4 13 78.44 20 15.41 375 116 1.39 / 25.39 6 19
5 8 0.08 244 15.37 259 971 2.36 / 26.36 6 146
Average= 2.93
(KJ/cycle)

Cycle 7 GMT 2/ 9/2023 11:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 22 15.34 388 131 0.13 / 20.18 6 6
2 10 1023.00 3 15.25 1636 75 0.21 / 20.26 6 12
3 7 2004.96 40 14.88 2863 1704 1.91 / 21.96 12 19
4 13 1156.48 20 15.02 1817 546 2.46 / 22.51 6 27
5 13 570.56 20 15.16 1058 321 2.78 / 22.83 6 30
6 13 123.64 20 15.29 442 135 2.91 / 22.96 6 21
7 13 29.12 20 15.31 304 93 3.00 / 23.06 6 19
8 8 0.20 240 15.28 257 942 3.95 / 24.00 6 139
Average= 3.00
(KJ/cycle)

Cycle 6 GMT 28/ 8/2023 3: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 21 15.28 378 121 0.12 / 17.82 6 6
2 10 1033.84 3 15.23 1634 75 0.20 / 17.89 6 11
3 7 1005.32 40 15.24 1618 986 1.18 / 18.88 11 30
4 13 131.28 20 15.42 448 138 1.32 / 19.01 6 19
5 13 39.56 20 15.42 313 97 1.42 / 19.11 6 18
6 8 0.12 242 15.38 253 942 2.36 / 20.05 6 138
Average= 2.86
(KJ/cycle)

Cycle 5 GMT 22/ 8/2023 23:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 31 15.37 391 186 0.19 / 14.00 6 6
2 3 768.20 -4 15.59 11 0 0.00 / 14.00 6 6
3 7 2002.36 40 14.88 2861 1703 1.89 / 15.71 6 19
4 13 1153.84 20 15.03 1809 544 2.43 / 16.25 6 28
5 13 473.28 20 15.20 928 282 2.72 / 16.53 6 28
6 13 125.00 20 15.29 444 136 2.85 / 16.67 6 22
7 13 14.52 20 15.32 280 86 2.94 / 16.76 6 19
8 8 -0.04 240 15.28 256 939 3.88 / 17.69 6 158
Average= 2.95
(KJ/cycle)

Cycle 4 GMT 17/ 8/2023 14:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 31 15.29 389 184 0.18 / 11.83 6 6
2 3 749.16 -4 15.59 11 0 0.00 / 11.83 6 6
3 7 814.12 41 15.35 1348 848 1.03 / 12.67 6 23
4 13 110.28 20 15.46 422 130 1.16 / 12.80 6 19
5 13 22.44 20 15.46 295 91 1.25 / 12.90 6 20
6 8 0.04 233 15.42 257 923 2.18 / 13.82 6 138
Average= 2.76
(KJ/cycle)

Cycle 3 GMT 12/ 8/2023 11:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 30 15.29 378 173 0.17 / 8.52 6 6
2 3 787.28 -3 15.59 11 0 0.00 / 8.52 6 6
3 7 1428.80 40 15.10 2144 1295 1.47 / 9.81 6 19
4 13 992.16 20 15.14 1607 487 1.95 / 10.30 6 26
5 13 285.00 20 15.30 663 203 2.16 / 10.50 6 24
6 13 89.04 20 15.34 396 121 2.28 / 10.63 6 20
7 8 0.12 255 15.32 260 1016 3.30 / 11.64 6 149
Average= 2.91
(KJ/cycle)

Cycle 2 GMT 11/ 8/2023 1:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 31 15.29 380 180 0.18 / 5.17 6 6
2 7 1516.72 40 15.08 2222 1340 1.52 / 6.51 6 19
3 13 1065.36 20 15.12 1697 513 2.03 / 7.02 6 26
4 13 350.16 20 15.28 749 229 2.26 / 7.25 6 25
5 13 79.92 20 15.34 369 113 2.38 / 7.36 6 19
6 13 21.64 20 15.35 285 87 2.46 / 7.45 6 17
7 8 0.08 235 15.31 249 896 3.36 / 8.35 6 135
Average= 2.78
(KJ/cycle)

Cycle 1 GMT 9/ 8/2023 15:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 31 15.49 352 169 0.17 / 1.56 6 6
2 10 1059.04 11 15.27 1666 280 0.45 / 1.84 6 6
3 10 1143.16 8 15.23 1752 213 0.66 / 2.05 6 7
4 3 1144.60 4 15.22 1763 107 0.77 / 2.16 6 7
5 7 1381.80 40 15.03 2078 1249 2.02 / 3.41 7 16
6 13 656.48 20 15.18 1165 354 2.37 / 3.76 6 24
7 13 178.72 20 15.31 512 157 2.53 / 3.92 6 21
8 13 65.44 20 15.34 346 106 2.64 / 4.02 6 17
9 8 1.24 255 15.31 247 964 3.60 / 4.99 6 148
Average= 2.49
(KJ/cycle)

Cycle 0 GMT 9/ 8/2023 7:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 30 15.63 391 183 0.18 / 0.18 6 6
2 7 132.32 40 15.62 391 244 0.43 / 0.43 6 7
3 13 85.24 20 15.60 327 102 0.53 / 0.53 6 7
4 13 22.08 20 15.60 243 76 0.61 / 0.61 6 9
5 8 0.16 238 15.56 211 781 1.39 / 1.39 6 146
Average= 1.39
(KJ/cycle)