SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.12 | 18 | 14.69 | 490 | 130 | 0.13 / 481.39 | 5 | 6 |
2 | 7 | 2005.72 | 40 | 14.29 | 3166 | 1810 | 1.94 / 483.20 | 6 | 11 |
3 | 13 | 1583.32 | 20 | 14.31 | 2604 | 745 | 2.68 / 483.94 | 5 | 12 |
4 | 13 | 892.52 | 20 | 14.44 | 1637 | 473 | 3.16 / 484.41 | 5 | 22 |
5 | 13 | 245.52 | 20 | 14.66 | 698 | 205 | 3.36 / 484.62 | 5 | 19 |
6 | 13 | 89.44 | 20 | 14.71 | 464 | 137 | 3.50 / 484.75 | 5 | 17 |
7 | 8 | 0.00 | 287 | 14.69 | 325 | 1370 | 4.87 / 486.12 | 5 | 141 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 18 | 14.68 | 469 | 124 | 0.12 / 476.58 | 5 | 6 |
2 | 7 | 2005.56 | 40 | 14.29 | 3175 | 1815 | 1.94 / 478.40 | 6 | 7 |
3 | 13 | 1506.92 | 20 | 14.33 | 2478 | 710 | 2.65 / 479.11 | 5 | 14 |
4 | 13 | 903.20 | 20 | 14.44 | 1649 | 476 | 3.13 / 479.58 | 5 | 22 |
5 | 13 | 190.24 | 20 | 14.68 | 622 | 183 | 3.31 / 479.76 | 5 | 19 |
6 | 13 | 41.96 | 20 | 14.73 | 404 | 119 | 3.43 / 479.88 | 5 | 17 |
7 | 8 | 0.04 | 285 | 14.68 | 328 | 1372 | 4.80 / 481.26 | 5 | 138 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 18 | 14.71 | 467 | 124 | 0.12 / 471.85 | 5 | 6 |
2 | 7 | 2010.48 | 40 | 14.30 | 3173 | 1815 | 1.94 / 473.66 | 6 | 10 |
3 | 13 | 1463.64 | 20 | 14.33 | 2425 | 695 | 2.63 / 474.36 | 5 | 18 |
4 | 13 | 869.76 | 20 | 14.44 | 1608 | 464 | 3.10 / 474.82 | 5 | 21 |
5 | 13 | 120.00 | 20 | 14.69 | 514 | 151 | 3.25 / 474.97 | 5 | 23 |
6 | 13 | 49.64 | 20 | 14.71 | 419 | 123 | 3.37 / 475.10 | 5 | 20 |
7 | 8 | -0.04 | 285 | 14.68 | 325 | 1360 | 4.73 / 476.46 | 5 | 141 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 18 | 14.69 | 465 | 123 | 0.12 / 467.09 | 6 | 6 |
2 | 7 | 2003.60 | 41 | 14.29 | 3159 | 1851 | 1.97 / 468.95 | 6 | 11 |
3 | 13 | 1501.16 | 20 | 14.33 | 2464 | 706 | 2.68 / 469.65 | 5 | 13 |
4 | 13 | 866.88 | 20 | 14.44 | 1596 | 461 | 3.14 / 470.11 | 5 | 23 |
5 | 13 | 149.60 | 20 | 14.68 | 556 | 163 | 3.30 / 470.28 | 5 | 22 |
6 | 13 | 44.40 | 20 | 14.72 | 404 | 119 | 3.42 / 470.39 | 5 | 19 |
7 | 8 | 0.00 | 285 | 14.68 | 318 | 1330 | 4.75 / 471.72 | 5 | 140 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 18 | 14.70 | 463 | 123 | 0.12 / 462.28 | 6 | 6 |
2 | 7 | 2009.88 | 41 | 14.29 | 3166 | 1855 | 1.98 / 464.13 | 6 | 9 |
3 | 13 | 1496.20 | 20 | 14.33 | 2463 | 706 | 2.68 / 464.84 | 5 | 16 |
4 | 13 | 897.20 | 20 | 14.43 | 1638 | 473 | 3.16 / 465.31 | 5 | 21 |
5 | 13 | 205.12 | 20 | 14.66 | 641 | 188 | 3.34 / 465.50 | 5 | 21 |
6 | 13 | 46.96 | 20 | 14.72 | 408 | 120 | 3.46 / 465.62 | 5 | 18 |
7 | 8 | -0.04 | 285 | 14.68 | 323 | 1351 | 4.82 / 466.97 | 5 | 142 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 18 | 14.70 | 461 | 122 | 0.12 / 457.51 | 6 | 6 |
2 | 7 | 2007.84 | 40 | 14.30 | 3175 | 1816 | 1.94 / 459.33 | 6 | 9 |
3 | 13 | 1532.76 | 20 | 14.32 | 2516 | 721 | 2.66 / 460.05 | 5 | 17 |
4 | 13 | 891.40 | 20 | 14.43 | 1632 | 471 | 3.13 / 460.52 | 5 | 18 |
5 | 13 | 211.64 | 20 | 14.67 | 644 | 189 | 3.32 / 460.71 | 5 | 22 |
6 | 13 | 52.00 | 20 | 14.72 | 408 | 120 | 3.44 / 460.83 | 5 | 20 |
7 | 8 | 0.08 | 285 | 14.69 | 317 | 1327 | 4.77 / 462.16 | 5 | 139 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 18 | 14.69 | 472 | 125 | 0.12 / 452.69 | 6 | 6 |
2 | 7 | 2010.92 | 41 | 14.29 | 3193 | 1871 | 2.00 / 454.56 | 6 | 10 |
3 | 13 | 1499.76 | 20 | 14.33 | 2479 | 710 | 2.71 / 455.27 | 5 | 13 |
4 | 13 | 924.32 | 20 | 14.43 | 1670 | 482 | 3.19 / 455.75 | 5 | 20 |
5 | 13 | 186.88 | 20 | 14.68 | 608 | 179 | 3.37 / 455.93 | 5 | 22 |
6 | 13 | 33.36 | 20 | 14.74 | 380 | 112 | 3.48 / 456.04 | 5 | 14 |
7 | 8 | 0.20 | 282 | 14.69 | 326 | 1350 | 4.83 / 457.39 | 5 | 135 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 17 | 14.69 | 469 | 117 | 0.12 / 447.88 | 6 | 6 |
2 | 3 | 1519.76 | 1 | 14.56 | 2513 | 37 | 0.15 / 447.92 | 5 | 16 |
3 | 7 | 2014.80 | 40 | 14.30 | 3174 | 1816 | 1.97 / 449.73 | 16 | 7 |
4 | 13 | 1450.36 | 20 | 14.34 | 2413 | 692 | 2.66 / 450.43 | 5 | 16 |
5 | 13 | 851.52 | 20 | 14.45 | 1577 | 456 | 3.12 / 450.88 | 5 | 23 |
6 | 13 | 204.16 | 20 | 14.66 | 644 | 189 | 3.31 / 451.07 | 5 | 24 |
7 | 13 | 42.76 | 20 | 14.72 | 401 | 118 | 3.42 / 451.19 | 5 | 25 |
8 | 8 | 0.00 | 285 | 14.68 | 328 | 1372 | 4.80 / 452.56 | 5 | 134 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 17 | 14.70 | 469 | 117 | 0.12 / 443.10 | 6 | 6 |
2 | 7 | 2013.28 | 40 | 14.29 | 3179 | 1817 | 1.93 / 444.92 | 6 | 8 |
3 | 13 | 1512.48 | 20 | 14.32 | 2489 | 713 | 2.65 / 445.63 | 5 | 15 |
4 | 13 | 912.24 | 20 | 14.44 | 1659 | 479 | 3.13 / 446.11 | 5 | 22 |
5 | 13 | 181.48 | 20 | 14.68 | 611 | 179 | 3.31 / 446.29 | 5 | 20 |
6 | 13 | 38.04 | 20 | 14.73 | 400 | 118 | 3.42 / 446.40 | 5 | 15 |
7 | 8 | 0.00 | 285 | 14.68 | 325 | 1360 | 4.78 / 447.76 | 5 | 139 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 18 | 14.70 | 459 | 121 | 0.12 / 438.29 | 6 | 6 |
2 | 7 | 2008.44 | 40 | 14.30 | 3169 | 1813 | 1.93 / 440.10 | 6 | 9 |
3 | 13 | 1471.12 | 20 | 14.34 | 2438 | 699 | 2.63 / 440.80 | 5 | 14 |
4 | 13 | 947.52 | 20 | 14.42 | 1717 | 495 | 3.13 / 441.30 | 5 | 24 |
5 | 13 | 205.84 | 20 | 14.67 | 643 | 189 | 3.32 / 441.49 | 5 | 20 |
6 | 13 | 27.60 | 20 | 14.74 | 379 | 112 | 3.43 / 441.60 | 5 | 17 |
7 | 8 | 0.00 | 289 | 14.69 | 326 | 1384 | 4.81 / 442.98 | 5 | 144 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 18 | 14.70 | 466 | 123 | 0.12 / 433.55 | 6 | 6 |
2 | 7 | 2007.68 | 40 | 14.29 | 3182 | 1819 | 1.94 / 435.36 | 6 | 12 |
3 | 13 | 1468.96 | 20 | 14.33 | 2425 | 695 | 2.64 / 436.06 | 5 | 10 |
4 | 13 | 869.12 | 20 | 14.45 | 1597 | 462 | 3.10 / 436.52 | 5 | 20 |
5 | 13 | 175.60 | 20 | 14.68 | 595 | 175 | 3.27 / 436.70 | 5 | 17 |
6 | 13 | 38.48 | 20 | 14.73 | 393 | 116 | 3.39 / 436.81 | 5 | 16 |
7 | 8 | -0.08 | 287 | 14.68 | 322 | 1357 | 4.75 / 438.17 | 5 | 147 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 18 | 14.72 | 464 | 123 | 0.12 / 428.76 | 6 | 6 |
2 | 7 | 2013.32 | 41 | 14.28 | 3183 | 1864 | 1.99 / 430.63 | 6 | 12 |
3 | 13 | 1514.52 | 20 | 14.33 | 2493 | 714 | 2.70 / 431.34 | 5 | 17 |
4 | 13 | 871.92 | 20 | 14.45 | 1605 | 464 | 3.16 / 431.80 | 5 | 20 |
5 | 13 | 221.00 | 20 | 14.67 | 659 | 193 | 3.36 / 432.00 | 5 | 18 |
6 | 13 | 36.56 | 20 | 14.74 | 384 | 113 | 3.47 / 432.11 | 5 | 13 |
7 | 8 | -0.08 | 285 | 14.71 | 313 | 1312 | 4.78 / 433.42 | 5 | 131 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.64 | 18 | 14.71 | 477 | 126 | 0.13 / 424.00 | 6 | 6 |
2 | 7 | 2009.64 | 40 | 14.30 | 3178 | 1818 | 1.94 / 425.81 | 6 | 9 |
3 | 13 | 1522.44 | 20 | 14.32 | 2502 | 717 | 2.66 / 426.53 | 5 | 12 |
4 | 13 | 885.12 | 20 | 14.45 | 1625 | 470 | 3.13 / 427.00 | 5 | 24 |
5 | 13 | 239.88 | 20 | 14.67 | 679 | 199 | 3.33 / 427.20 | 5 | 17 |
6 | 13 | 54.08 | 20 | 14.74 | 402 | 119 | 3.45 / 427.32 | 5 | 12 |
7 | 8 | 0.00 | 287 | 14.71 | 313 | 1321 | 4.77 / 428.64 | 5 | 130 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 18 | 14.71 | 473 | 125 | 0.13 / 419.21 | 6 | 6 |
2 | 7 | 2013.72 | 40 | 14.29 | 3177 | 1816 | 1.94 / 421.03 | 6 | 12 |
3 | 13 | 1475.32 | 20 | 14.33 | 2452 | 703 | 2.64 / 421.73 | 5 | 17 |
4 | 13 | 910.40 | 20 | 14.44 | 1657 | 479 | 3.12 / 422.21 | 5 | 22 |
5 | 13 | 213.84 | 20 | 14.68 | 647 | 190 | 3.31 / 422.40 | 5 | 17 |
6 | 13 | 67.36 | 20 | 14.74 | 427 | 126 | 3.44 / 422.53 | 5 | 14 |
7 | 8 | 0.04 | 289 | 14.71 | 316 | 1343 | 4.78 / 423.87 | 5 | 142 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 18 | 14.71 | 474 | 126 | 0.13 / 414.33 | 6 | 6 |
2 | 7 | 2014.36 | 40 | 14.29 | 3187 | 1822 | 1.95 / 416.15 | 6 | 12 |
3 | 13 | 1556.24 | 20 | 14.32 | 2549 | 730 | 2.68 / 416.88 | 5 | 14 |
4 | 13 | 947.44 | 20 | 14.43 | 1702 | 491 | 3.17 / 417.37 | 5 | 22 |
5 | 13 | 295.20 | 20 | 14.65 | 768 | 225 | 3.39 / 417.59 | 5 | 21 |
6 | 13 | 124.20 | 20 | 14.70 | 516 | 152 | 3.55 / 417.74 | 5 | 14 |
7 | 8 | 0.04 | 291 | 14.70 | 314 | 1343 | 4.89 / 419.09 | 5 | 142 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.64 | 18 | 14.72 | 477 | 126 | 0.13 / 409.50 | 6 | 6 |
2 | 7 | 2010.52 | 40 | 14.29 | 3175 | 1815 | 1.94 / 411.31 | 6 | 15 |
3 | 13 | 1513.32 | 20 | 14.32 | 2491 | 713 | 2.65 / 412.03 | 5 | 15 |
4 | 13 | 873.92 | 20 | 14.46 | 1601 | 463 | 3.12 / 412.49 | 5 | 21 |
5 | 13 | 270.08 | 20 | 14.66 | 733 | 215 | 3.33 / 412.71 | 5 | 20 |
6 | 13 | 74.12 | 20 | 14.74 | 438 | 129 | 3.46 / 412.83 | 5 | 12 |
7 | 8 | 0.04 | 289 | 14.71 | 321 | 1365 | 4.83 / 414.20 | 5 | 132 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 18 | 14.72 | 461 | 122 | 0.12 / 404.67 | 6 | 6 |
2 | 7 | 2004.20 | 41 | 14.30 | 3151 | 1847 | 1.97 / 406.52 | 6 | 11 |
3 | 13 | 1500.20 | 20 | 14.33 | 2474 | 709 | 2.68 / 407.22 | 5 | 15 |
4 | 13 | 895.04 | 20 | 14.45 | 1642 | 475 | 3.15 / 407.70 | 5 | 23 |
5 | 13 | 235.72 | 20 | 14.68 | 685 | 201 | 3.35 / 407.90 | 5 | 18 |
6 | 13 | 52.20 | 20 | 14.75 | 408 | 120 | 3.47 / 408.02 | 5 | 13 |
7 | 8 | 0.00 | 291 | 14.71 | 316 | 1353 | 4.83 / 409.37 | 5 | 151 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 18 | 14.71 | 479 | 127 | 0.13 / 399.85 | 6 | 6 |
2 | 7 | 2011.64 | 40 | 14.30 | 3169 | 1813 | 1.94 / 401.67 | 6 | 11 |
3 | 13 | 1511.28 | 20 | 14.34 | 2497 | 716 | 2.66 / 402.38 | 5 | 16 |
4 | 13 | 885.84 | 20 | 14.45 | 1620 | 468 | 3.12 / 402.85 | 5 | 21 |
5 | 13 | 271.96 | 20 | 14.66 | 735 | 216 | 3.34 / 403.07 | 5 | 16 |
6 | 13 | 75.64 | 20 | 14.73 | 446 | 131 | 3.47 / 403.20 | 5 | 11 |
7 | 8 | 0.00 | 289 | 14.71 | 317 | 1348 | 4.82 / 404.55 | 5 | 134 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.00 | 18 | 14.72 | 476 | 126 | 0.13 / 395.04 | 6 | 6 |
2 | 7 | 2005.60 | 40 | 14.30 | 3173 | 1815 | 1.94 / 396.85 | 6 | 13 |
3 | 13 | 1512.68 | 20 | 14.33 | 2493 | 714 | 2.66 / 397.57 | 5 | 19 |
4 | 13 | 917.04 | 20 | 14.45 | 1668 | 482 | 3.14 / 398.05 | 5 | 21 |
5 | 13 | 256.72 | 20 | 14.67 | 705 | 207 | 3.34 / 398.26 | 5 | 15 |
6 | 13 | 63.44 | 20 | 14.74 | 418 | 123 | 3.47 / 398.38 | 5 | 11 |
7 | 8 | 0.04 | 291 | 14.71 | 315 | 1348 | 4.82 / 399.73 | 5 | 145 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 18 | 14.73 | 466 | 124 | 0.12 / 390.27 | 6 | 6 |
2 | 7 | 2008.28 | 40 | 14.30 | 3179 | 1818 | 1.94 / 392.09 | 6 | 11 |
3 | 13 | 1425.76 | 20 | 14.36 | 2386 | 685 | 2.63 / 392.77 | 5 | 15 |
4 | 13 | 915.56 | 20 | 14.45 | 1664 | 481 | 3.11 / 393.25 | 5 | 19 |
5 | 13 | 228.04 | 20 | 14.69 | 659 | 194 | 3.30 / 393.45 | 5 | 17 |
6 | 13 | 47.64 | 20 | 14.76 | 393 | 116 | 3.42 / 393.56 | 5 | 11 |
7 | 8 | 0.04 | 289 | 14.72 | 317 | 1349 | 4.77 / 394.91 | 5 | 142 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 18 | 14.72 | 473 | 125 | 0.13 / 385.47 | 6 | 6 |
2 | 7 | 2004.88 | 41 | 14.31 | 3149 | 1848 | 1.97 / 387.32 | 6 | 14 |
3 | 13 | 1466.04 | 20 | 14.34 | 2430 | 697 | 2.67 / 388.02 | 5 | 14 |
4 | 13 | 903.12 | 20 | 14.45 | 1646 | 476 | 3.15 / 388.49 | 5 | 25 |
5 | 13 | 241.20 | 20 | 14.67 | 689 | 202 | 3.35 / 388.70 | 5 | 14 |
6 | 13 | 51.44 | 20 | 14.75 | 400 | 118 | 3.47 / 388.81 | 5 | 10 |
7 | 8 | 0.04 | 289 | 14.72 | 313 | 1332 | 4.80 / 390.15 | 5 | 134 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 18 | 14.72 | 469 | 124 | 0.12 / 380.67 | 6 | 6 |
2 | 7 | 2003.48 | 40 | 14.31 | 3155 | 1806 | 1.93 / 382.48 | 6 | 9 |
3 | 13 | 1542.32 | 20 | 14.33 | 2532 | 726 | 2.66 / 383.20 | 5 | 17 |
4 | 13 | 921.04 | 20 | 14.45 | 1679 | 485 | 3.14 / 383.69 | 5 | 19 |
5 | 13 | 228.64 | 20 | 14.69 | 671 | 197 | 3.34 / 383.88 | 5 | 17 |
6 | 13 | 45.44 | 20 | 14.76 | 392 | 116 | 3.45 / 384.00 | 5 | 9 |
7 | 8 | 0.04 | 289 | 14.72 | 317 | 1349 | 4.80 / 385.35 | 5 | 146 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 18 | 14.73 | 468 | 124 | 0.12 / 375.81 | 6 | 6 |
2 | 7 | 2004.84 | 40 | 14.32 | 3168 | 1815 | 1.94 / 377.62 | 6 | 15 |
3 | 13 | 1505.88 | 20 | 14.34 | 2502 | 718 | 2.66 / 378.34 | 5 | 17 |
4 | 13 | 978.24 | 20 | 14.43 | 1754 | 506 | 3.16 / 378.84 | 5 | 27 |
5 | 13 | 276.72 | 20 | 14.67 | 736 | 216 | 3.38 / 379.06 | 5 | 17 |
6 | 13 | 80.88 | 20 | 14.74 | 448 | 132 | 3.51 / 379.19 | 5 | 11 |
7 | 8 | 0.12 | 289 | 14.72 | 318 | 1353 | 4.86 / 380.55 | 5 | 133 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 18 | 14.72 | 471 | 125 | 0.12 / 370.99 | 6 | 6 |
2 | 7 | 2004.04 | 40 | 14.32 | 3165 | 1813 | 1.94 / 372.81 | 6 | 7 |
3 | 13 | 1508.84 | 20 | 14.35 | 2498 | 717 | 2.65 / 373.52 | 5 | 15 |
4 | 13 | 912.00 | 20 | 14.46 | 1669 | 483 | 3.14 / 374.01 | 5 | 21 |
5 | 13 | 224.00 | 20 | 14.69 | 662 | 194 | 3.33 / 374.20 | 5 | 18 |
6 | 13 | 66.84 | 20 | 14.75 | 437 | 129 | 3.46 / 374.33 | 5 | 15 |
7 | 8 | 0.04 | 287 | 14.72 | 320 | 1352 | 4.81 / 375.68 | 5 | 139 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 18 | 14.71 | 461 | 122 | 0.12 / 366.15 | 6 | 6 |
2 | 7 | 2009.84 | 41 | 14.31 | 3171 | 1860 | 1.98 / 368.02 | 6 | 14 |
3 | 13 | 1509.08 | 20 | 14.35 | 2478 | 711 | 2.69 / 368.73 | 5 | 16 |
4 | 13 | 899.80 | 20 | 14.46 | 1638 | 474 | 3.17 / 369.20 | 5 | 18 |
5 | 13 | 171.64 | 20 | 14.71 | 589 | 173 | 3.34 / 369.37 | 5 | 15 |
6 | 13 | 33.68 | 20 | 14.76 | 389 | 115 | 3.46 / 369.49 | 5 | 13 |
7 | 8 | 0.04 | 289 | 14.71 | 325 | 1382 | 4.84 / 370.87 | 5 | 139 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 18 | 14.72 | 461 | 122 | 0.12 / 361.42 | 6 | 6 |
2 | 7 | 2009.84 | 40 | 14.32 | 3164 | 1812 | 1.93 / 363.23 | 6 | 10 |
3 | 13 | 1485.04 | 20 | 14.36 | 2441 | 701 | 2.64 / 363.93 | 5 | 15 |
4 | 13 | 881.76 | 20 | 14.47 | 1614 | 467 | 3.10 / 364.40 | 5 | 22 |
5 | 13 | 197.88 | 20 | 14.70 | 623 | 183 | 3.29 / 364.58 | 5 | 19 |
6 | 13 | 39.32 | 20 | 14.76 | 386 | 114 | 3.40 / 364.70 | 5 | 16 |
7 | 8 | 0.00 | 289 | 14.72 | 314 | 1336 | 4.74 / 366.03 | 5 | 144 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 17 | 14.73 | 461 | 115 | 0.12 / 356.74 | 6 | 6 |
2 | 7 | 2015.72 | 40 | 14.33 | 3161 | 1812 | 1.93 / 358.55 | 6 | 10 |
3 | 13 | 1375.24 | 20 | 14.38 | 2299 | 661 | 2.59 / 359.21 | 5 | 15 |
4 | 13 | 829.12 | 20 | 14.49 | 1531 | 444 | 3.03 / 359.66 | 5 | 22 |
5 | 13 | 180.72 | 20 | 14.71 | 595 | 175 | 3.21 / 359.83 | 5 | 19 |
6 | 13 | 30.32 | 20 | 14.77 | 378 | 112 | 3.32 / 359.94 | 5 | 16 |
7 | 8 | 0.08 | 287 | 14.71 | 321 | 1355 | 4.67 / 361.30 | 5 | 141 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 17 | 14.72 | 453 | 113 | 0.11 / 352.04 | 6 | 6 |
2 | 7 | 2003.96 | 40 | 14.33 | 3151 | 1806 | 1.92 / 353.85 | 6 | 9 |
3 | 13 | 1504.28 | 20 | 14.37 | 2470 | 710 | 2.63 / 354.56 | 5 | 17 |
4 | 13 | 821.48 | 20 | 14.50 | 1524 | 442 | 3.07 / 355.00 | 5 | 21 |
5 | 13 | 175.36 | 20 | 14.71 | 591 | 174 | 3.25 / 355.17 | 5 | 21 |
6 | 13 | 32.76 | 20 | 14.77 | 375 | 111 | 3.36 / 355.28 | 5 | 18 |
7 | 8 | 0.00 | 287 | 14.72 | 317 | 1339 | 4.70 / 356.62 | 5 | 147 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 17 | 14.72 | 465 | 116 | 0.12 / 347.26 | 6 | 6 |
2 | 7 | 2003.84 | 41 | 14.34 | 3154 | 1854 | 1.97 / 349.11 | 6 | 8 |
3 | 13 | 1479.48 | 20 | 14.37 | 2435 | 700 | 2.67 / 349.81 | 5 | 12 |
4 | 13 | 840.68 | 20 | 14.49 | 1553 | 450 | 3.12 / 350.26 | 5 | 22 |
5 | 13 | 206.96 | 20 | 14.70 | 642 | 189 | 3.31 / 350.45 | 5 | 24 |
6 | 13 | 35.56 | 20 | 14.76 | 392 | 116 | 3.43 / 350.57 | 5 | 20 |
7 | 8 | 0.00 | 287 | 14.71 | 322 | 1359 | 4.78 / 351.93 | 5 | 135 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 17 | 14.72 | 464 | 116 | 0.12 / 342.50 | 6 | 6 |
2 | 7 | 2005.28 | 40 | 14.34 | 3165 | 1815 | 1.93 / 344.32 | 6 | 9 |
3 | 13 | 1475.36 | 20 | 14.37 | 2435 | 700 | 2.63 / 345.02 | 5 | 13 |
4 | 13 | 871.60 | 20 | 14.49 | 1593 | 462 | 3.09 / 345.48 | 5 | 22 |
5 | 13 | 186.56 | 20 | 14.71 | 607 | 179 | 3.27 / 345.66 | 5 | 21 |
6 | 13 | 32.12 | 20 | 14.77 | 381 | 113 | 3.38 / 345.77 | 5 | 16 |
7 | 8 | -0.12 | 289 | 14.72 | 323 | 1374 | 4.76 / 347.14 | 5 | 136 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 17 | 14.74 | 457 | 115 | 0.11 / 337.76 | 5 | 6 |
2 | 7 | 2005.08 | 40 | 14.34 | 3147 | 1805 | 1.92 / 339.57 | 6 | 10 |
3 | 13 | 1500.52 | 20 | 14.37 | 2466 | 709 | 2.63 / 340.28 | 5 | 15 |
4 | 13 | 845.48 | 20 | 14.50 | 1559 | 452 | 3.08 / 340.73 | 5 | 23 |
5 | 13 | 155.08 | 20 | 14.73 | 562 | 166 | 3.25 / 340.90 | 5 | 20 |
6 | 13 | 37.48 | 20 | 14.77 | 393 | 116 | 3.36 / 341.01 | 5 | 15 |
7 | 8 | -0.08 | 287 | 14.72 | 325 | 1373 | 4.74 / 342.38 | 5 | 137 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 18 | 14.74 | 459 | 122 | 0.12 / 332.97 | 6 | 6 |
2 | 7 | 2013.76 | 41 | 14.33 | 3175 | 1865 | 1.99 / 334.83 | 6 | 11 |
3 | 13 | 1502.96 | 20 | 14.37 | 2473 | 711 | 2.70 / 335.54 | 5 | 13 |
4 | 13 | 854.40 | 20 | 14.50 | 1574 | 456 | 3.15 / 336.00 | 5 | 23 |
5 | 13 | 198.12 | 20 | 14.72 | 627 | 185 | 3.34 / 336.18 | 5 | 20 |
6 | 13 | 19.08 | 20 | 14.78 | 353 | 104 | 3.44 / 336.29 | 5 | 12 |
7 | 8 | 0.08 | 287 | 14.73 | 322 | 1361 | 4.80 / 337.65 | 5 | 145 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 18 | 14.74 | 472 | 125 | 0.13 / 328.16 | 6 | 6 |
2 | 7 | 2011.36 | 40 | 14.34 | 3167 | 1817 | 1.94 / 329.98 | 6 | 9 |
3 | 13 | 1520.84 | 20 | 14.37 | 2502 | 719 | 2.66 / 330.70 | 5 | 14 |
4 | 13 | 916.68 | 20 | 14.48 | 1661 | 481 | 3.14 / 331.18 | 5 | 23 |
5 | 13 | 224.80 | 20 | 14.71 | 657 | 193 | 3.34 / 331.37 | 5 | 20 |
6 | 13 | 29.24 | 20 | 14.78 | 369 | 109 | 3.44 / 331.48 | 5 | 16 |
7 | 8 | 0.08 | 289 | 14.73 | 321 | 1366 | 4.81 / 332.85 | 5 | 142 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 18 | 14.74 | 470 | 125 | 0.12 / 323.32 | 5 | 6 |
2 | 7 | 2012.96 | 40 | 14.34 | 3181 | 1825 | 1.95 / 325.14 | 6 | 9 |
3 | 13 | 1551.72 | 20 | 14.37 | 2544 | 731 | 2.68 / 325.87 | 5 | 13 |
4 | 13 | 950.44 | 20 | 14.48 | 1707 | 494 | 3.17 / 326.37 | 5 | 23 |
5 | 13 | 222.48 | 20 | 14.72 | 657 | 193 | 3.37 / 326.56 | 5 | 20 |
6 | 13 | 29.44 | 20 | 14.79 | 370 | 109 | 3.48 / 326.67 | 5 | 13 |
7 | 8 | 0.08 | 289 | 14.74 | 320 | 1363 | 4.84 / 328.03 | 5 | 130 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 17 | 14.75 | 469 | 118 | 0.12 / 318.52 | 5 | 6 |
2 | 7 | 2010.48 | 40 | 14.34 | 3161 | 1813 | 1.93 / 320.33 | 6 | 8 |
3 | 13 | 1546.52 | 20 | 14.38 | 2527 | 727 | 2.66 / 321.06 | 5 | 13 |
4 | 13 | 901.00 | 20 | 14.50 | 1632 | 473 | 3.13 / 321.53 | 5 | 23 |
5 | 13 | 218.20 | 20 | 14.72 | 654 | 193 | 3.32 / 321.73 | 5 | 18 |
6 | 13 | 27.68 | 20 | 14.80 | 367 | 109 | 3.43 / 321.83 | 5 | 9 |
7 | 8 | -0.04 | 289 | 14.75 | 319 | 1360 | 4.79 / 323.19 | 5 | 148 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 17 | 14.75 | 461 | 116 | 0.12 / 313.83 | 5 | 6 |
2 | 7 | 2003.88 | 41 | 14.34 | 3163 | 1860 | 1.98 / 315.69 | 6 | 12 |
3 | 13 | 1394.24 | 20 | 14.40 | 2326 | 670 | 2.65 / 316.36 | 5 | 17 |
4 | 13 | 810.88 | 20 | 14.53 | 1508 | 438 | 3.08 / 316.80 | 5 | 24 |
5 | 13 | 202.12 | 20 | 14.74 | 620 | 183 | 3.27 / 316.98 | 5 | 18 |
6 | 8 | 0.08 | 306 | 14.76 | 314 | 1418 | 4.68 / 318.40 | 5 | 135 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 17 | 14.75 | 480 | 120 | 0.12 / 309.09 | 5 | 6 |
2 | 7 | 2013.04 | 40 | 14.35 | 3150 | 1808 | 1.93 / 310.90 | 6 | 9 |
3 | 13 | 1470.80 | 20 | 14.40 | 2414 | 695 | 2.62 / 311.59 | 5 | 17 |
4 | 13 | 880.08 | 20 | 14.51 | 1594 | 463 | 3.09 / 312.06 | 5 | 21 |
5 | 13 | 227.64 | 20 | 14.73 | 659 | 194 | 3.28 / 312.25 | 5 | 19 |
6 | 13 | 16.36 | 20 | 14.81 | 337 | 100 | 3.38 / 312.35 | 5 | 17 |
7 | 8 | 0.04 | 289 | 14.75 | 321 | 1368 | 4.75 / 313.72 | 5 | 144 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 17 | 14.75 | 465 | 117 | 0.12 / 304.39 | 5 | 6 |
2 | 7 | 2013.60 | 40 | 14.35 | 3163 | 1816 | 1.93 / 306.21 | 6 | 11 |
3 | 13 | 1485.68 | 20 | 14.40 | 2453 | 706 | 2.64 / 306.91 | 5 | 14 |
4 | 13 | 846.40 | 20 | 14.53 | 1548 | 450 | 3.09 / 307.36 | 5 | 19 |
5 | 13 | 210.20 | 20 | 14.74 | 637 | 188 | 3.28 / 307.55 | 5 | 18 |
6 | 8 | 0.08 | 306 | 14.76 | 314 | 1418 | 4.69 / 308.97 | 5 | 132 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 17 | 14.75 | 478 | 120 | 0.12 / 299.65 | 5 | 6 |
2 | 7 | 2007.68 | 41 | 14.35 | 3158 | 1858 | 1.98 / 301.51 | 6 | 9 |
3 | 13 | 1459.24 | 20 | 14.40 | 2410 | 694 | 2.67 / 302.21 | 5 | 14 |
4 | 13 | 855.08 | 20 | 14.53 | 1564 | 454 | 3.13 / 302.66 | 5 | 21 |
5 | 13 | 165.28 | 20 | 14.76 | 570 | 168 | 3.29 / 302.83 | 5 | 17 |
6 | 8 | 0.12 | 306 | 14.76 | 320 | 1445 | 4.74 / 304.27 | 5 | 134 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 17 | 14.76 | 467 | 117 | 0.12 / 294.87 | 5 | 6 |
2 | 7 | 2011.48 | 40 | 14.35 | 3165 | 1817 | 1.93 / 296.68 | 6 | 9 |
3 | 13 | 1521.12 | 20 | 14.40 | 2483 | 715 | 2.65 / 297.40 | 5 | 16 |
4 | 13 | 955.52 | 20 | 14.50 | 1691 | 490 | 3.14 / 297.89 | 5 | 20 |
5 | 13 | 235.20 | 20 | 14.73 | 670 | 197 | 3.34 / 298.09 | 5 | 18 |
6 | 8 | 0.04 | 308 | 14.77 | 318 | 1447 | 4.78 / 299.53 | 5 | 132 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 17 | 14.75 | 479 | 120 | 0.12 / 290.17 | 5 | 6 |
2 | 7 | 2008.36 | 40 | 14.35 | 3183 | 1827 | 1.95 / 291.99 | 6 | 11 |
3 | 13 | 1499.92 | 20 | 14.41 | 2460 | 709 | 2.66 / 292.70 | 5 | 15 |
4 | 13 | 823.00 | 20 | 14.55 | 1519 | 442 | 3.10 / 293.15 | 5 | 22 |
5 | 13 | 181.00 | 20 | 14.76 | 586 | 173 | 3.27 / 293.32 | 5 | 18 |
6 | 8 | 0.20 | 306 | 14.77 | 317 | 1433 | 4.70 / 294.75 | 5 | 138 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 17 | 14.76 | 464 | 116 | 0.12 / 285.46 | 5 | 6 |
2 | 7 | 2012.04 | 40 | 14.35 | 3182 | 1826 | 1.94 / 287.29 | 6 | 11 |
3 | 13 | 1433.76 | 20 | 14.42 | 2377 | 686 | 2.63 / 287.97 | 5 | 15 |
4 | 13 | 844.00 | 20 | 14.54 | 1553 | 452 | 3.08 / 288.42 | 5 | 20 |
5 | 13 | 194.48 | 20 | 14.76 | 613 | 181 | 3.26 / 288.61 | 5 | 19 |
6 | 8 | 0.16 | 306 | 14.77 | 319 | 1442 | 4.70 / 290.05 | 5 | 149 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 17 | 14.76 | 461 | 116 | 0.12 / 280.72 | 5 | 6 |
2 | 7 | 2008.24 | 41 | 14.35 | 3169 | 1864 | 1.98 / 282.59 | 6 | 8 |
3 | 13 | 1474.60 | 20 | 14.41 | 2429 | 700 | 2.68 / 283.29 | 5 | 13 |
4 | 13 | 840.76 | 20 | 14.55 | 1550 | 451 | 3.13 / 283.74 | 5 | 21 |
5 | 13 | 183.68 | 20 | 14.77 | 599 | 177 | 3.31 / 283.92 | 5 | 17 |
6 | 8 | -0.12 | 306 | 14.77 | 316 | 1428 | 4.74 / 285.34 | 5 | 150 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 17 | 14.77 | 470 | 118 | 0.12 / 275.94 | 5 | 6 |
2 | 7 | 2004.60 | 40 | 14.36 | 3158 | 1814 | 1.93 / 277.75 | 6 | 10 |
3 | 13 | 1544.96 | 20 | 14.41 | 2517 | 725 | 2.66 / 278.48 | 5 | 16 |
4 | 13 | 898.80 | 20 | 14.53 | 1634 | 475 | 3.13 / 278.95 | 5 | 21 |
5 | 13 | 244.00 | 20 | 14.75 | 682 | 201 | 3.33 / 279.16 | 5 | 19 |
6 | 8 | 0.20 | 308 | 14.78 | 319 | 1452 | 4.79 / 280.61 | 5 | 143 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 17 | 14.77 | 470 | 118 | 0.12 / 271.16 | 5 | 6 |
2 | 7 | 2004.48 | 40 | 14.37 | 3151 | 1811 | 1.93 / 272.97 | 6 | 10 |
3 | 13 | 1500.20 | 20 | 14.41 | 2475 | 713 | 2.64 / 273.68 | 5 | 14 |
4 | 13 | 942.20 | 20 | 14.52 | 1698 | 493 | 3.14 / 274.18 | 5 | 24 |
5 | 13 | 216.24 | 20 | 14.76 | 640 | 189 | 3.32 / 274.37 | 5 | 15 |
6 | 8 | 0.12 | 306 | 14.78 | 322 | 1456 | 4.78 / 275.82 | 5 | 131 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 17 | 14.76 | 477 | 120 | 0.12 / 266.40 | 5 | 6 |
2 | 7 | 2011.72 | 41 | 14.36 | 3168 | 1865 | 1.98 / 268.27 | 6 | 10 |
3 | 13 | 1433.40 | 20 | 14.43 | 2376 | 686 | 2.67 / 268.95 | 5 | 18 |
4 | 13 | 835.60 | 20 | 14.55 | 1551 | 451 | 3.12 / 269.41 | 5 | 22 |
5 | 13 | 178.60 | 20 | 14.77 | 595 | 176 | 3.30 / 269.58 | 5 | 20 |
6 | 8 | 0.08 | 304 | 14.78 | 325 | 1460 | 4.76 / 271.04 | 5 | 142 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 17 | 14.76 | 468 | 117 | 0.12 / 261.67 | 5 | 6 |
2 | 7 | 2007.52 | 40 | 14.36 | 3174 | 1823 | 1.94 / 263.50 | 6 | 8 |
3 | 13 | 1472.92 | 20 | 14.43 | 2432 | 702 | 2.64 / 264.20 | 5 | 16 |
4 | 13 | 836.60 | 20 | 14.55 | 1549 | 451 | 3.09 / 264.65 | 5 | 24 |
5 | 13 | 155.20 | 20 | 14.78 | 564 | 167 | 3.26 / 264.82 | 5 | 21 |
6 | 8 | 0.20 | 304 | 14.77 | 327 | 1468 | 4.73 / 266.28 | 5 | 131 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 17 | 14.76 | 474 | 119 | 0.12 / 256.94 | 5 | 6 |
2 | 7 | 2010.12 | 40 | 14.37 | 3161 | 1817 | 1.94 / 258.75 | 6 | 12 |
3 | 13 | 1542.44 | 20 | 14.42 | 2527 | 729 | 2.66 / 259.48 | 5 | 18 |
4 | 13 | 798.92 | 20 | 14.57 | 1497 | 436 | 3.10 / 259.92 | 5 | 25 |
5 | 13 | 136.96 | 20 | 14.79 | 535 | 158 | 3.26 / 260.08 | 5 | 18 |
6 | 8 | 0.00 | 304 | 14.78 | 329 | 1478 | 4.74 / 261.56 | 5 | 146 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 17 | 14.76 | 467 | 117 | 0.12 / 252.21 | 5 | 6 |
2 | 7 | 2010.80 | 40 | 14.37 | 3173 | 1824 | 1.94 / 254.03 | 6 | 8 |
3 | 13 | 1478.84 | 20 | 14.43 | 2453 | 708 | 2.65 / 254.74 | 5 | 22 |
4 | 13 | 834.20 | 20 | 14.56 | 1551 | 452 | 3.10 / 255.19 | 5 | 25 |
5 | 13 | 110.24 | 20 | 14.81 | 497 | 147 | 3.25 / 255.34 | 5 | 15 |
6 | 8 | 0.04 | 302 | 14.78 | 331 | 1477 | 4.73 / 256.82 | 5 | 134 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 17 | 14.77 | 460 | 116 | 0.12 / 247.51 | 5 | 6 |
2 | 7 | 2013.92 | 40 | 14.37 | 3179 | 1827 | 1.94 / 249.34 | 6 | 11 |
3 | 13 | 1469.84 | 20 | 14.43 | 2430 | 701 | 2.64 / 250.04 | 5 | 21 |
4 | 13 | 861.00 | 20 | 14.56 | 1579 | 460 | 3.10 / 250.50 | 5 | 25 |
5 | 13 | 134.52 | 20 | 14.80 | 528 | 156 | 3.26 / 250.66 | 5 | 14 |
6 | 8 | 0.04 | 302 | 14.79 | 321 | 1434 | 4.69 / 252.09 | 5 | 138 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 17 | 14.78 | 471 | 118 | 0.12 / 242.76 | 5 | 6 |
2 | 7 | 2010.28 | 40 | 14.37 | 3187 | 1832 | 1.95 / 244.60 | 6 | 10 |
3 | 13 | 1464.80 | 20 | 14.44 | 2424 | 700 | 2.65 / 245.30 | 5 | 16 |
4 | 13 | 922.44 | 20 | 14.54 | 1670 | 486 | 3.14 / 245.78 | 5 | 21 |
5 | 13 | 133.04 | 20 | 14.80 | 528 | 156 | 3.29 / 245.94 | 5 | 17 |
6 | 8 | 0.04 | 304 | 14.78 | 325 | 1460 | 4.75 / 247.40 | 5 | 138 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 17 | 14.79 | 466 | 117 | 0.12 / 238.05 | 5 | 6 |
2 | 7 | 2004.04 | 40 | 14.37 | 3170 | 1822 | 1.94 / 239.87 | 6 | 8 |
3 | 13 | 1523.00 | 20 | 14.43 | 2502 | 722 | 2.66 / 240.59 | 5 | 18 |
4 | 13 | 841.48 | 20 | 14.57 | 1553 | 453 | 3.11 / 241.04 | 5 | 21 |
5 | 13 | 153.64 | 20 | 14.80 | 551 | 163 | 3.28 / 241.21 | 5 | 18 |
6 | 8 | 0.04 | 304 | 14.80 | 320 | 1440 | 4.72 / 242.65 | 5 | 143 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 17 | 14.78 | 481 | 121 | 0.12 / 233.30 | 5 | 6 |
2 | 7 | 2014.72 | 40 | 14.38 | 3182 | 1830 | 1.95 / 235.13 | 6 | 8 |
3 | 13 | 1474.64 | 20 | 14.44 | 2431 | 702 | 2.65 / 235.83 | 5 | 15 |
4 | 13 | 878.64 | 20 | 14.56 | 1609 | 469 | 3.12 / 236.30 | 5 | 21 |
5 | 13 | 215.08 | 20 | 14.78 | 644 | 190 | 3.31 / 236.49 | 5 | 19 |
6 | 8 | -0.04 | 304 | 14.80 | 320 | 1440 | 4.75 / 237.93 | 5 | 136 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 17 | 14.78 | 484 | 122 | 0.12 / 228.55 | 5 | 6 |
2 | 7 | 2012.40 | 40 | 14.38 | 3178 | 1828 | 1.95 / 230.38 | 6 | 10 |
3 | 13 | 1426.80 | 20 | 14.45 | 2379 | 688 | 2.64 / 231.07 | 5 | 15 |
4 | 13 | 908.76 | 20 | 14.56 | 1650 | 480 | 3.12 / 231.55 | 5 | 22 |
5 | 13 | 170.20 | 20 | 14.81 | 580 | 172 | 3.29 / 231.72 | 5 | 17 |
6 | 8 | 0.16 | 306 | 14.80 | 322 | 1458 | 4.75 / 233.18 | 5 | 147 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 17 | 14.79 | 492 | 124 | 0.12 / 223.81 | 5 | 6 |
2 | 7 | 2009.92 | 40 | 14.37 | 3178 | 1827 | 1.95 / 225.64 | 6 | 12 |
3 | 13 | 1465.36 | 20 | 14.44 | 2426 | 701 | 2.65 / 226.34 | 5 | 16 |
4 | 13 | 846.44 | 20 | 14.57 | 1565 | 456 | 3.11 / 226.79 | 5 | 21 |
5 | 13 | 201.16 | 20 | 14.79 | 620 | 183 | 3.29 / 226.98 | 5 | 16 |
6 | 8 | 0.12 | 306 | 14.80 | 321 | 1454 | 4.74 / 228.43 | 5 | 138 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 17 | 14.81 | 480 | 121 | 0.12 / 219.04 | 5 | 6 |
2 | 7 | 2004.36 | 41 | 14.38 | 3171 | 1870 | 1.99 / 220.91 | 6 | 11 |
3 | 13 | 1383.20 | 20 | 14.46 | 2323 | 672 | 2.66 / 221.59 | 5 | 18 |
4 | 13 | 865.68 | 20 | 14.57 | 1594 | 464 | 3.13 / 222.05 | 5 | 24 |
5 | 13 | 205.00 | 20 | 14.80 | 627 | 186 | 3.31 / 222.24 | 5 | 18 |
6 | 8 | 0.20 | 306 | 14.81 | 320 | 1450 | 4.76 / 223.69 | 5 | 140 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 17 | 14.81 | 475 | 120 | 0.12 / 214.24 | 5 | 6 |
2 | 7 | 2009.60 | 40 | 14.39 | 3169 | 1824 | 1.94 / 216.06 | 6 | 10 |
3 | 13 | 1512.80 | 20 | 14.44 | 2476 | 715 | 2.66 / 216.78 | 5 | 13 |
4 | 13 | 951.20 | 20 | 14.55 | 1706 | 496 | 3.16 / 217.28 | 5 | 20 |
5 | 13 | 272.08 | 20 | 14.78 | 719 | 213 | 3.37 / 217.49 | 5 | 18 |
6 | 13 | 41.04 | 20 | 14.87 | 379 | 113 | 3.48 / 217.60 | 5 | 11 |
7 | 8 | 0.08 | 285 | 14.82 | 313 | 1322 | 4.80 / 218.92 | 5 | 136 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 17 | 14.81 | 456 | 115 | 0.11 / 209.43 | 5 | 6 |
2 | 7 | 2015.12 | 40 | 14.38 | 3188 | 1834 | 1.95 / 211.26 | 6 | 9 |
3 | 13 | 1513.84 | 20 | 14.43 | 2506 | 723 | 2.67 / 211.99 | 5 | 14 |
4 | 13 | 869.88 | 20 | 14.58 | 1597 | 466 | 3.14 / 212.45 | 5 | 21 |
5 | 13 | 250.64 | 20 | 14.79 | 691 | 204 | 3.34 / 212.66 | 5 | 16 |
6 | 13 | 90.40 | 20 | 14.84 | 453 | 134 | 3.48 / 212.79 | 5 | 12 |
7 | 8 | 0.08 | 287 | 14.82 | 313 | 1331 | 4.81 / 214.12 | 5 | 150 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.00 | 17 | 14.81 | 476 | 120 | 0.12 / 204.65 | 5 | 6 |
2 | 7 | 2006.64 | 40 | 14.39 | 3174 | 1827 | 1.95 / 206.48 | 6 | 6 |
3 | 13 | 1502.44 | 20 | 14.44 | 2488 | 719 | 2.67 / 207.20 | 5 | 14 |
4 | 13 | 870.28 | 20 | 14.58 | 1600 | 467 | 3.13 / 207.67 | 5 | 21 |
5 | 13 | 263.64 | 20 | 14.79 | 707 | 209 | 3.34 / 207.88 | 5 | 18 |
6 | 13 | 33.92 | 20 | 14.87 | 371 | 110 | 3.45 / 207.99 | 5 | 15 |
7 | 8 | 0.04 | 287 | 14.82 | 312 | 1327 | 4.78 / 209.31 | 5 | 136 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 17 | 14.81 | 466 | 117 | 0.12 / 199.82 | 5 | 6 |
2 | 7 | 2009.48 | 40 | 14.39 | 3169 | 1824 | 1.94 / 201.64 | 6 | 9 |
3 | 13 | 1554.88 | 20 | 14.44 | 2556 | 738 | 2.68 / 202.38 | 5 | 13 |
4 | 13 | 982.60 | 20 | 14.55 | 1756 | 511 | 3.19 / 202.89 | 5 | 19 |
5 | 13 | 255.16 | 20 | 14.79 | 702 | 208 | 3.40 / 203.10 | 5 | 13 |
6 | 13 | 32.16 | 20 | 14.88 | 369 | 110 | 3.51 / 203.21 | 5 | 11 |
7 | 8 | 0.04 | 287 | 14.83 | 312 | 1328 | 4.84 / 204.53 | 5 | 134 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 17 | 14.82 | 480 | 121 | 0.12 / 195.04 | 6 | 6 |
2 | 7 | 2010.76 | 40 | 14.40 | 3156 | 1818 | 1.94 / 196.86 | 6 | 7 |
3 | 13 | 1539.72 | 20 | 14.44 | 2530 | 731 | 2.67 / 197.59 | 5 | 18 |
4 | 13 | 891.36 | 20 | 14.58 | 1617 | 472 | 3.14 / 198.06 | 5 | 19 |
5 | 13 | 243.04 | 20 | 14.80 | 676 | 200 | 3.34 / 198.26 | 5 | 15 |
6 | 8 | 0.12 | 308 | 14.84 | 314 | 1435 | 4.78 / 199.70 | 5 | 145 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 17 | 14.82 | 467 | 118 | 0.12 / 190.27 | 6 | 6 |
2 | 7 | 2011.00 | 40 | 14.39 | 3189 | 1836 | 1.95 / 192.10 | 6 | 7 |
3 | 13 | 1521.80 | 20 | 14.44 | 2506 | 724 | 2.68 / 192.83 | 5 | 14 |
4 | 13 | 855.28 | 20 | 14.59 | 1587 | 463 | 3.14 / 193.29 | 5 | 19 |
5 | 13 | 242.00 | 20 | 14.80 | 686 | 203 | 3.34 / 193.49 | 5 | 14 |
6 | 8 | 0.20 | 304 | 14.84 | 317 | 1430 | 4.77 / 194.92 | 5 | 133 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 17 | 14.83 | 472 | 119 | 0.12 / 185.53 | 5 | 6 |
2 | 7 | 2003.48 | 40 | 14.39 | 3173 | 1826 | 1.95 / 187.36 | 6 | 9 |
3 | 13 | 1464.52 | 20 | 14.46 | 2429 | 702 | 2.65 / 188.06 | 5 | 10 |
4 | 13 | 888.60 | 20 | 14.58 | 1627 | 474 | 3.12 / 188.53 | 5 | 22 |
5 | 13 | 225.20 | 20 | 14.81 | 655 | 194 | 3.32 / 188.73 | 5 | 18 |
6 | 8 | 0.08 | 306 | 14.84 | 313 | 1421 | 4.74 / 190.15 | 5 | 142 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 17 | 14.83 | 466 | 117 | 0.12 / 180.81 | 5 | 6 |
2 | 7 | 2011.32 | 40 | 14.39 | 3192 | 1837 | 1.95 / 182.65 | 6 | 9 |
3 | 13 | 1430.96 | 20 | 14.47 | 2376 | 688 | 2.64 / 183.33 | 5 | 16 |
4 | 13 | 867.56 | 20 | 14.59 | 1596 | 466 | 3.11 / 183.80 | 5 | 22 |
5 | 13 | 206.20 | 20 | 14.82 | 625 | 185 | 3.29 / 183.98 | 5 | 15 |
6 | 13 | 58.08 | 20 | 14.87 | 404 | 120 | 3.41 / 184.11 | 5 | 11 |
7 | 8 | 0.04 | 285 | 14.84 | 309 | 1307 | 4.72 / 185.41 | 5 | 134 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.92 | 17 | 14.84 | 474 | 120 | 0.12 / 176.10 | 6 | 6 |
2 | 7 | 2014.24 | 40 | 14.39 | 3180 | 1830 | 1.95 / 177.93 | 6 | 10 |
3 | 13 | 1449.00 | 20 | 14.47 | 2411 | 698 | 2.65 / 178.62 | 5 | 15 |
4 | 13 | 848.04 | 20 | 14.59 | 1572 | 459 | 3.11 / 179.08 | 5 | 20 |
5 | 13 | 193.24 | 20 | 14.83 | 609 | 181 | 3.29 / 179.26 | 5 | 15 |
6 | 13 | 23.04 | 20 | 14.89 | 348 | 104 | 3.39 / 179.37 | 5 | 10 |
7 | 8 | 0.16 | 285 | 14.84 | 313 | 1324 | 4.71 / 180.69 | 5 | 134 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 17 | 14.84 | 478 | 121 | 0.12 / 171.40 | 5 | 6 |
2 | 7 | 2011.96 | 41 | 14.39 | 3173 | 1872 | 1.99 / 173.27 | 6 | 10 |
3 | 13 | 1451.24 | 20 | 14.47 | 2407 | 697 | 2.69 / 173.97 | 5 | 16 |
4 | 13 | 817.88 | 20 | 14.61 | 1525 | 446 | 3.13 / 174.42 | 5 | 21 |
5 | 13 | 203.60 | 20 | 14.82 | 621 | 184 | 3.32 / 174.60 | 5 | 15 |
6 | 8 | 0.20 | 306 | 14.85 | 303 | 1377 | 4.70 / 175.98 | 5 | 140 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 17 | 14.84 | 460 | 116 | 0.12 / 166.73 | 6 | 6 |
2 | 7 | 2008.80 | 40 | 14.39 | 3177 | 1829 | 1.94 / 168.56 | 6 | 10 |
3 | 13 | 1398.52 | 20 | 14.49 | 2338 | 678 | 2.62 / 169.24 | 5 | 16 |
4 | 13 | 804.52 | 20 | 14.62 | 1504 | 440 | 3.06 / 169.68 | 5 | 22 |
5 | 13 | 193.60 | 20 | 14.83 | 612 | 182 | 3.24 / 169.86 | 5 | 16 |
6 | 13 | 22.92 | 20 | 14.89 | 347 | 103 | 3.35 / 169.96 | 5 | 12 |
7 | 8 | -0.12 | 285 | 14.85 | 312 | 1320 | 4.67 / 171.28 | 5 | 140 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 17 | 14.83 | 475 | 120 | 0.12 / 161.90 | 5 | 6 |
2 | 7 | 2010.92 | 41 | 14.40 | 3177 | 1876 | 2.00 / 163.78 | 6 | 10 |
3 | 13 | 1517.16 | 20 | 14.47 | 2492 | 721 | 2.72 / 164.50 | 5 | 15 |
4 | 13 | 871.60 | 20 | 14.60 | 1600 | 467 | 3.18 / 164.96 | 5 | 21 |
5 | 13 | 184.32 | 20 | 14.84 | 595 | 177 | 3.36 / 165.14 | 5 | 16 |
6 | 13 | 73.72 | 20 | 14.87 | 430 | 128 | 3.49 / 165.27 | 5 | 14 |
7 | 8 | 0.20 | 287 | 14.84 | 316 | 1346 | 4.83 / 166.61 | 5 | 146 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 17 | 14.83 | 469 | 118 | 0.12 / 157.13 | 5 | 6 |
2 | 7 | 2012.12 | 40 | 14.41 | 3177 | 1831 | 1.95 / 158.96 | 6 | 8 |
3 | 13 | 1468.44 | 20 | 14.47 | 2418 | 700 | 2.65 / 159.66 | 5 | 15 |
4 | 13 | 861.76 | 20 | 14.61 | 1586 | 463 | 3.11 / 160.13 | 5 | 22 |
5 | 13 | 204.32 | 20 | 14.83 | 621 | 184 | 3.30 / 160.31 | 5 | 19 |
6 | 13 | 85.88 | 20 | 14.87 | 447 | 133 | 3.43 / 160.44 | 5 | 16 |
7 | 8 | 0.08 | 287 | 14.84 | 314 | 1337 | 4.77 / 161.78 | 5 | 144 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 17 | 14.84 | 473 | 119 | 0.12 / 152.32 | 6 | 6 |
2 | 7 | 2013.28 | 40 | 14.40 | 3178 | 1831 | 1.95 / 154.15 | 6 | 10 |
3 | 13 | 1474.36 | 20 | 14.47 | 2453 | 710 | 2.66 / 154.86 | 5 | 16 |
4 | 13 | 910.00 | 20 | 14.59 | 1657 | 484 | 3.14 / 155.35 | 5 | 22 |
5 | 13 | 215.44 | 20 | 14.82 | 643 | 191 | 3.33 / 155.54 | 5 | 19 |
6 | 13 | 63.24 | 20 | 14.88 | 420 | 125 | 3.46 / 155.66 | 5 | 13 |
7 | 8 | -0.08 | 287 | 14.84 | 317 | 1350 | 4.81 / 157.01 | 5 | 135 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 17 | 14.85 | 489 | 123 | 0.12 / 147.48 | 6 | 6 |
2 | 7 | 2008.64 | 40 | 14.41 | 3170 | 1827 | 1.95 / 149.30 | 6 | 10 |
3 | 13 | 1543.32 | 20 | 14.47 | 2530 | 732 | 2.68 / 150.04 | 5 | 14 |
4 | 13 | 926.04 | 20 | 14.59 | 1674 | 488 | 3.17 / 150.53 | 5 | 20 |
5 | 13 | 218.72 | 20 | 14.83 | 648 | 192 | 3.36 / 150.72 | 5 | 16 |
6 | 13 | 103.32 | 20 | 14.87 | 469 | 139 | 3.50 / 150.86 | 5 | 15 |
7 | 8 | 0.00 | 287 | 14.85 | 316 | 1347 | 4.85 / 152.20 | 5 | 133 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.28 | 17 | 14.85 | 479 | 121 | 0.12 / 142.70 | 5 | 6 |
2 | 7 | 2010.20 | 40 | 14.41 | 3172 | 1828 | 1.95 / 144.53 | 6 | 10 |
3 | 13 | 1477.92 | 20 | 14.48 | 2455 | 711 | 2.66 / 145.24 | 5 | 9 |
4 | 13 | 853.36 | 20 | 14.62 | 1563 | 457 | 3.12 / 145.69 | 5 | 20 |
5 | 13 | 240.92 | 20 | 14.83 | 668 | 198 | 3.32 / 145.89 | 5 | 16 |
6 | 13 | 93.92 | 20 | 14.88 | 454 | 135 | 3.45 / 146.03 | 5 | 11 |
7 | 8 | 0.08 | 289 | 14.86 | 309 | 1327 | 4.78 / 147.35 | 5 | 139 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 17 | 14.86 | 470 | 119 | 0.12 / 137.94 | 6 | 6 |
2 | 7 | 2011.16 | 40 | 14.42 | 3178 | 1833 | 1.95 / 139.78 | 6 | 9 |
3 | 13 | 1441.72 | 20 | 14.49 | 2397 | 695 | 2.65 / 140.47 | 5 | 15 |
4 | 13 | 811.68 | 20 | 14.63 | 1506 | 441 | 3.09 / 140.91 | 5 | 22 |
5 | 13 | 206.96 | 20 | 14.84 | 632 | 188 | 3.27 / 141.10 | 5 | 17 |
6 | 13 | 96.20 | 20 | 14.87 | 464 | 138 | 3.41 / 141.24 | 5 | 15 |
7 | 8 | 0.16 | 285 | 14.85 | 316 | 1337 | 4.75 / 142.58 | 5 | 134 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 17 | 14.86 | 452 | 114 | 0.11 / 133.12 | 6 | 6 |
2 | 7 | 2008.28 | 40 | 14.42 | 3176 | 1832 | 1.95 / 134.96 | 6 | 9 |
3 | 13 | 1484.84 | 20 | 14.49 | 2448 | 709 | 2.66 / 135.67 | 5 | 15 |
4 | 13 | 899.56 | 20 | 14.60 | 1634 | 477 | 3.13 / 136.14 | 5 | 21 |
5 | 13 | 281.36 | 20 | 14.81 | 733 | 217 | 3.35 / 136.36 | 5 | 16 |
6 | 13 | 86.80 | 20 | 14.88 | 443 | 132 | 3.48 / 136.49 | 5 | 13 |
7 | 8 | 0.08 | 287 | 14.86 | 313 | 1335 | 4.82 / 137.83 | 5 | 133 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 17 | 14.84 | 467 | 118 | 0.12 / 128.35 | 5 | 6 |
2 | 7 | 2006.56 | 40 | 14.42 | 3170 | 1828 | 1.95 / 130.18 | 6 | 9 |
3 | 13 | 1447.80 | 20 | 14.50 | 2391 | 693 | 2.64 / 130.87 | 5 | 14 |
4 | 13 | 960.04 | 20 | 14.59 | 1719 | 502 | 3.14 / 131.37 | 5 | 22 |
5 | 13 | 218.52 | 20 | 14.85 | 635 | 189 | 3.33 / 131.56 | 5 | 14 |
6 | 13 | 75.72 | 20 | 14.90 | 430 | 128 | 3.46 / 131.69 | 5 | 12 |
7 | 8 | 0.00 | 287 | 14.87 | 310 | 1323 | 4.78 / 133.01 | 5 | 141 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 17 | 14.86 | 467 | 118 | 0.12 / 123.54 | 6 | 6 |
2 | 7 | 2005.20 | 40 | 14.43 | 3154 | 1820 | 1.94 / 125.36 | 6 | 10 |
3 | 13 | 1457.76 | 20 | 14.50 | 2413 | 700 | 2.64 / 126.06 | 5 | 15 |
4 | 13 | 880.44 | 20 | 14.61 | 1615 | 472 | 3.11 / 126.53 | 5 | 21 |
5 | 13 | 197.76 | 20 | 14.84 | 622 | 185 | 3.29 / 126.72 | 5 | 18 |
6 | 13 | 83.88 | 20 | 14.88 | 460 | 137 | 3.43 / 126.86 | 5 | 15 |
7 | 8 | 0.12 | 287 | 14.86 | 322 | 1373 | 4.80 / 128.23 | 5 | 143 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.08 | 17 | 14.86 | 476 | 120 | 0.12 / 118.76 | 6 | 6 |
2 | 7 | 2007.52 | 40 | 14.43 | 3171 | 1830 | 1.95 / 120.59 | 6 | 9 |
3 | 13 | 1481.52 | 20 | 14.50 | 2448 | 710 | 2.66 / 121.30 | 5 | 15 |
4 | 13 | 916.00 | 20 | 14.61 | 1656 | 484 | 3.14 / 121.78 | 5 | 22 |
5 | 13 | 192.88 | 20 | 14.85 | 613 | 182 | 3.33 / 121.96 | 5 | 18 |
6 | 13 | 52.72 | 20 | 14.90 | 401 | 119 | 3.45 / 122.08 | 5 | 13 |
7 | 8 | 0.04 | 289 | 14.86 | 312 | 1340 | 4.79 / 123.42 | 5 | 141 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 17 | 14.86 | 470 | 119 | 0.12 / 113.88 | 6 | 6 |
2 | 7 | 2007.32 | 40 | 14.43 | 3194 | 1844 | 1.96 / 115.73 | 6 | 10 |
3 | 13 | 1490.04 | 20 | 14.50 | 2457 | 713 | 2.67 / 116.44 | 5 | 14 |
4 | 13 | 926.44 | 20 | 14.60 | 1675 | 489 | 3.16 / 116.93 | 5 | 21 |
5 | 13 | 212.76 | 20 | 14.84 | 643 | 191 | 3.35 / 117.12 | 5 | 20 |
6 | 13 | 69.96 | 20 | 14.89 | 427 | 127 | 3.48 / 117.25 | 5 | 14 |
7 | 8 | 0.08 | 289 | 14.86 | 324 | 1391 | 4.87 / 118.64 | 5 | 144 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 17 | 14.87 | 457 | 116 | 0.12 / 109.05 | 6 | 6 |
2 | 7 | 2013.04 | 40 | 14.43 | 3183 | 1837 | 1.95 / 110.89 | 6 | 8 |
3 | 13 | 1548.60 | 20 | 14.49 | 2538 | 736 | 2.69 / 111.62 | 5 | 12 |
4 | 13 | 853.88 | 20 | 14.63 | 1582 | 463 | 3.15 / 112.09 | 5 | 21 |
5 | 13 | 202.04 | 20 | 14.85 | 626 | 186 | 3.34 / 112.27 | 5 | 17 |
6 | 13 | 96.52 | 20 | 14.89 | 465 | 138 | 3.48 / 112.41 | 5 | 14 |
7 | 8 | 0.00 | 287 | 14.87 | 317 | 1353 | 4.83 / 113.76 | 5 | 144 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 17 | 14.86 | 484 | 122 | 0.12 / 104.26 | 6 | 6 |
2 | 7 | 2011.84 | 41 | 14.44 | 3173 | 1879 | 2.00 / 106.13 | 6 | 6 |
3 | 13 | 1360.28 | 20 | 14.53 | 2286 | 664 | 2.67 / 106.80 | 5 | 16 |
4 | 13 | 870.24 | 20 | 14.63 | 1596 | 467 | 3.13 / 107.27 | 5 | 20 |
5 | 13 | 224.56 | 20 | 14.85 | 659 | 196 | 3.33 / 107.46 | 5 | 15 |
6 | 13 | 73.12 | 20 | 14.91 | 422 | 126 | 3.45 / 107.59 | 5 | 12 |
7 | 8 | 0.00 | 287 | 14.88 | 316 | 1349 | 4.80 / 108.94 | 5 | 145 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 17 | 14.86 | 460 | 116 | 0.12 / 99.52 | 6 | 6 |
2 | 7 | 2013.60 | 40 | 14.44 | 3181 | 1837 | 1.95 / 101.36 | 6 | 10 |
3 | 13 | 1502.84 | 20 | 14.51 | 2472 | 717 | 2.67 / 102.08 | 5 | 14 |
4 | 13 | 796.40 | 20 | 14.65 | 1486 | 435 | 3.11 / 102.51 | 5 | 23 |
5 | 13 | 91.52 | 20 | 14.89 | 464 | 138 | 3.24 / 102.65 | 5 | 17 |
6 | 13 | 37.04 | 20 | 14.91 | 385 | 115 | 3.36 / 102.76 | 5 | 17 |
7 | 8 | -0.04 | 285 | 14.87 | 323 | 1369 | 4.73 / 104.13 | 5 | 138 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 17 | 14.86 | 469 | 118 | 0.12 / 94.71 | 6 | 6 |
2 | 7 | 2011.32 | 40 | 14.45 | 3175 | 1835 | 1.95 / 96.54 | 6 | 9 |
3 | 13 | 1550.72 | 20 | 14.50 | 2544 | 738 | 2.69 / 97.28 | 5 | 14 |
4 | 13 | 829.36 | 20 | 14.64 | 1552 | 454 | 3.15 / 97.73 | 5 | 20 |
5 | 13 | 145.60 | 20 | 14.86 | 545 | 162 | 3.31 / 97.90 | 5 | 22 |
6 | 13 | 31.92 | 20 | 14.90 | 391 | 117 | 3.42 / 98.01 | 5 | 21 |
7 | 8 | 0.00 | 285 | 14.86 | 329 | 1393 | 4.82 / 99.40 | 5 | 149 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 17 | 14.88 | 453 | 115 | 0.11 / 89.97 | 6 | 6 |
2 | 7 | 2012.12 | 40 | 14.45 | 3164 | 1829 | 1.94 / 91.79 | 6 | 10 |
3 | 13 | 1420.60 | 20 | 14.53 | 2353 | 684 | 2.63 / 92.48 | 5 | 14 |
4 | 13 | 867.16 | 20 | 14.63 | 1594 | 466 | 3.09 / 92.94 | 5 | 21 |
5 | 13 | 127.64 | 20 | 14.88 | 514 | 153 | 3.25 / 93.10 | 5 | 20 |
6 | 13 | 33.84 | 20 | 14.91 | 378 | 113 | 3.36 / 93.21 | 5 | 17 |
7 | 8 | -0.12 | 287 | 14.86 | 323 | 1378 | 4.74 / 94.59 | 5 | 143 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 17 | 14.89 | 466 | 118 | 0.12 / 85.15 | 6 | 6 |
2 | 7 | 2007.96 | 40 | 14.45 | 3178 | 1837 | 1.95 / 86.98 | 6 | 9 |
3 | 13 | 1509.64 | 20 | 14.51 | 2479 | 719 | 2.67 / 87.70 | 5 | 12 |
4 | 13 | 864.04 | 20 | 14.64 | 1592 | 466 | 3.14 / 88.17 | 5 | 20 |
5 | 13 | 202.04 | 20 | 14.86 | 632 | 188 | 3.33 / 88.36 | 5 | 17 |
6 | 13 | 85.48 | 20 | 14.90 | 448 | 134 | 3.46 / 88.49 | 5 | 14 |
7 | 8 | 0.04 | 289 | 14.88 | 316 | 1359 | 4.82 / 89.85 | 5 | 140 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 17 | 14.90 | 445 | 113 | 0.11 / 80.36 | 6 | 6 |
2 | 7 | 2015.24 | 40 | 14.45 | 3179 | 1837 | 1.95 / 82.20 | 6 | 8 |
3 | 13 | 1452.76 | 20 | 14.53 | 2399 | 697 | 2.65 / 82.90 | 5 | 13 |
4 | 13 | 860.24 | 20 | 14.65 | 1589 | 466 | 3.11 / 83.36 | 5 | 19 |
5 | 13 | 219.36 | 20 | 14.87 | 642 | 191 | 3.30 / 83.55 | 5 | 12 |
6 | 13 | 111.44 | 20 | 14.90 | 482 | 144 | 3.45 / 83.70 | 5 | 11 |
7 | 8 | 0.12 | 287 | 14.89 | 312 | 1333 | 4.78 / 85.03 | 5 | 137 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 17 | 14.90 | 448 | 113 | 0.11 / 75.54 | 6 | 6 |
2 | 7 | 2005.40 | 40 | 14.46 | 3186 | 1843 | 1.96 / 77.38 | 6 | 9 |
3 | 13 | 1470.52 | 20 | 14.53 | 2429 | 706 | 2.66 / 78.09 | 5 | 15 |
4 | 13 | 869.48 | 20 | 14.65 | 1600 | 469 | 3.13 / 78.56 | 5 | 19 |
5 | 13 | 290.56 | 20 | 14.85 | 748 | 222 | 3.35 / 78.78 | 5 | 15 |
6 | 13 | 125.88 | 20 | 14.90 | 505 | 150 | 3.50 / 78.93 | 5 | 13 |
7 | 8 | 0.00 | 287 | 14.90 | 309 | 1321 | 4.82 / 80.25 | 5 | 141 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.40 | 17 | 14.89 | 480 | 122 | 0.12 / 70.68 | 6 | 6 |
2 | 7 | 2011.08 | 40 | 14.47 | 3171 | 1835 | 1.96 / 72.52 | 6 | 8 |
3 | 13 | 1478.44 | 20 | 14.53 | 2433 | 707 | 2.66 / 73.22 | 5 | 15 |
4 | 13 | 936.28 | 20 | 14.63 | 1688 | 494 | 3.16 / 73.72 | 5 | 20 |
5 | 13 | 230.08 | 20 | 14.87 | 656 | 195 | 3.35 / 73.91 | 5 | 14 |
6 | 13 | 112.08 | 20 | 14.90 | 496 | 148 | 3.50 / 74.06 | 5 | 12 |
7 | 8 | 0.00 | 289 | 14.89 | 317 | 1364 | 4.86 / 75.42 | 5 | 132 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 17 | 14.88 | 482 | 122 | 0.12 / 65.80 | 6 | 6 |
2 | 7 | 2003.52 | 40 | 14.47 | 3153 | 1825 | 1.95 / 67.63 | 6 | 9 |
3 | 13 | 1542.64 | 20 | 14.52 | 2534 | 736 | 2.68 / 68.36 | 5 | 15 |
4 | 13 | 897.24 | 20 | 14.65 | 1640 | 481 | 3.16 / 68.84 | 5 | 20 |
5 | 13 | 208.24 | 20 | 14.88 | 639 | 190 | 3.35 / 69.03 | 5 | 16 |
6 | 13 | 87.88 | 20 | 14.91 | 451 | 134 | 3.49 / 69.17 | 5 | 13 |
7 | 8 | 0.04 | 289 | 14.89 | 323 | 1390 | 4.88 / 70.56 | 5 | 137 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 16 | 14.89 | 468 | 111 | 0.11 / 61.00 | 6 | 6 |
2 | 7 | 2004.16 | 40 | 14.47 | 3168 | 1834 | 1.95 / 62.83 | 6 | 10 |
3 | 13 | 1434.04 | 20 | 14.55 | 2393 | 696 | 2.64 / 63.53 | 5 | 15 |
4 | 13 | 836.24 | 20 | 14.66 | 1552 | 455 | 3.10 / 63.98 | 5 | 20 |
5 | 13 | 184.68 | 20 | 14.88 | 606 | 180 | 3.28 / 64.16 | 5 | 15 |
6 | 13 | 69.08 | 20 | 14.92 | 431 | 129 | 3.41 / 64.29 | 5 | 14 |
7 | 8 | 0.04 | 289 | 14.89 | 323 | 1390 | 4.80 / 65.68 | 5 | 142 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 16 | 14.89 | 466 | 111 | 0.11 / 56.20 | 6 | 6 |
2 | 7 | 2010.88 | 40 | 14.48 | 3171 | 1837 | 1.95 / 58.04 | 6 | 10 |
3 | 13 | 1498.92 | 20 | 14.54 | 2455 | 714 | 2.66 / 58.75 | 5 | 14 |
4 | 13 | 866.84 | 20 | 14.66 | 1594 | 467 | 3.13 / 59.22 | 5 | 19 |
5 | 13 | 149.08 | 20 | 14.90 | 539 | 161 | 3.29 / 59.38 | 5 | 15 |
6 | 13 | 74.80 | 20 | 14.92 | 437 | 130 | 3.42 / 59.51 | 5 | 15 |
7 | 8 | 0.12 | 291 | 14.89 | 318 | 1378 | 4.80 / 60.89 | 5 | 148 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 16 | 14.88 | 483 | 115 | 0.11 / 51.46 | 6 | 6 |
2 | 7 | 2003.00 | 40 | 14.49 | 3152 | 1827 | 1.94 / 53.29 | 6 | 10 |
3 | 13 | 1444.12 | 20 | 14.56 | 2403 | 700 | 2.64 / 53.99 | 5 | 13 |
4 | 13 | 837.36 | 20 | 14.67 | 1560 | 458 | 3.10 / 54.45 | 5 | 21 |
5 | 13 | 116.56 | 20 | 14.91 | 489 | 146 | 3.25 / 54.59 | 5 | 18 |
6 | 13 | 22.60 | 20 | 14.94 | 359 | 107 | 3.35 / 54.70 | 5 | 17 |
7 | 8 | 0.00 | 287 | 14.89 | 325 | 1389 | 4.74 / 56.09 | 5 | 134 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 16 | 14.88 | 473 | 113 | 0.11 / 46.71 | 6 | 6 |
2 | 7 | 2010.96 | 40 | 14.48 | 3180 | 1842 | 1.95 / 48.55 | 6 | 10 |
3 | 13 | 1465.44 | 20 | 14.55 | 2441 | 710 | 2.66 / 49.26 | 5 | 12 |
4 | 13 | 746.60 | 20 | 14.70 | 1425 | 419 | 3.08 / 49.68 | 5 | 22 |
5 | 13 | 136.20 | 20 | 14.89 | 547 | 163 | 3.25 / 49.84 | 5 | 19 |
6 | 13 | 27.36 | 20 | 14.94 | 372 | 111 | 3.36 / 49.96 | 5 | 17 |
7 | 8 | -0.04 | 285 | 14.88 | 328 | 1391 | 4.75 / 51.35 | 5 | 144 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 16 | 14.88 | 486 | 116 | 0.12 / 41.85 | 5 | 6 |
2 | 7 | 2004.60 | 40 | 14.50 | 3133 | 1817 | 1.93 / 43.66 | 6 | 9 |
3 | 13 | 1546.92 | 20 | 14.53 | 2535 | 737 | 2.67 / 44.40 | 5 | 14 |
4 | 13 | 900.96 | 20 | 14.65 | 1646 | 482 | 3.15 / 44.88 | 5 | 21 |
5 | 13 | 208.96 | 20 | 14.87 | 645 | 192 | 3.34 / 45.07 | 5 | 22 |
6 | 13 | 22.36 | 20 | 14.94 | 359 | 107 | 3.45 / 45.18 | 5 | 19 |
7 | 8 | 0.00 | 287 | 14.88 | 332 | 1418 | 4.87 / 46.60 | 5 | 141 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 16 | 14.89 | 479 | 114 | 0.11 / 37.01 | 6 | 6 |
2 | 7 | 2013.20 | 40 | 14.49 | 3189 | 1848 | 1.96 / 38.86 | 6 | 6 |
3 | 13 | 1446.04 | 20 | 14.56 | 2421 | 705 | 2.67 / 39.57 | 5 | 14 |
4 | 13 | 885.32 | 20 | 14.66 | 1628 | 477 | 3.14 / 40.04 | 5 | 21 |
5 | 13 | 141.72 | 20 | 14.91 | 527 | 157 | 3.30 / 40.20 | 5 | 19 |
6 | 13 | 34.44 | 20 | 14.94 | 380 | 114 | 3.42 / 40.31 | 5 | 17 |
7 | 8 | 0.20 | 289 | 14.89 | 329 | 1416 | 4.83 / 41.73 | 5 | 145 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 16 | 14.92 | 469 | 112 | 0.11 / 32.24 | 6 | 6 |
2 | 7 | 2008.72 | 40 | 14.50 | 3149 | 1826 | 1.94 / 34.07 | 6 | 9 |
3 | 13 | 1424.00 | 20 | 14.56 | 2396 | 698 | 2.64 / 34.76 | 5 | 15 |
4 | 13 | 764.28 | 20 | 14.70 | 1466 | 431 | 3.07 / 35.19 | 5 | 22 |
5 | 13 | 118.24 | 20 | 14.91 | 526 | 157 | 3.22 / 35.35 | 5 | 18 |
6 | 13 | 39.28 | 20 | 14.94 | 400 | 120 | 3.34 / 35.47 | 5 | 16 |
7 | 8 | 0.00 | 287 | 14.89 | 334 | 1427 | 4.77 / 36.90 | 5 | 145 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 16 | 14.94 | 383 | 92 | 0.09 / 27.76 | 6 | 6 |
2 | 7 | 2008.08 | 40 | 14.51 | 3131 | 1817 | 1.91 / 29.58 | 6 | 10 |
3 | 13 | 1500.28 | 20 | 14.56 | 2429 | 707 | 2.62 / 30.29 | 5 | 14 |
4 | 13 | 806.12 | 20 | 14.70 | 1454 | 427 | 3.04 / 30.72 | 5 | 21 |
5 | 13 | 157.32 | 20 | 14.93 | 503 | 150 | 3.19 / 30.87 | 5 | 15 |
6 | 13 | 85.24 | 20 | 14.95 | 388 | 116 | 3.31 / 30.98 | 5 | 13 |
7 | 8 | 0.00 | 285 | 14.93 | 269 | 1145 | 4.45 / 32.13 | 5 | 136 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 16 | 14.94 | 389 | 93 | 0.09 / 23.40 | 6 | 6 |
2 | 7 | 2007.72 | 40 | 14.52 | 3125 | 1815 | 1.91 / 25.21 | 6 | 9 |
3 | 13 | 1422.64 | 20 | 14.58 | 2331 | 680 | 2.59 / 25.89 | 5 | 13 |
4 | 13 | 785.92 | 20 | 14.71 | 1427 | 420 | 3.01 / 26.31 | 5 | 22 |
5 | 13 | 208.64 | 20 | 14.91 | 577 | 172 | 3.18 / 26.48 | 5 | 16 |
6 | 13 | 88.64 | 20 | 14.95 | 390 | 117 | 3.30 / 26.60 | 5 | 13 |
7 | 8 | 0.12 | 287 | 14.94 | 250 | 1072 | 4.37 / 27.67 | 5 | 144 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 16 | 14.93 | 389 | 93 | 0.09 / 19.02 | 6 | 6 |
2 | 7 | 2009.84 | 40 | 14.52 | 3128 | 1817 | 1.91 / 20.83 | 6 | 10 |
3 | 13 | 1466.44 | 20 | 14.57 | 2391 | 697 | 2.61 / 21.53 | 5 | 13 |
4 | 13 | 820.52 | 20 | 14.70 | 1478 | 435 | 3.04 / 21.96 | 5 | 21 |
5 | 13 | 206.72 | 20 | 14.91 | 565 | 168 | 3.21 / 22.13 | 5 | 15 |
6 | 13 | 97.80 | 20 | 14.95 | 400 | 120 | 3.33 / 22.25 | 5 | 13 |
7 | 8 | 0.12 | 285 | 14.95 | 247 | 1052 | 4.38 / 23.30 | 5 | 133 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 16 | 14.93 | 383 | 91 | 0.09 / 14.64 | 6 | 6 |
2 | 7 | 2012.60 | 40 | 14.51 | 3148 | 1827 | 1.92 / 16.47 | 6 | 9 |
3 | 13 | 1431.24 | 20 | 14.58 | 2342 | 683 | 2.60 / 17.15 | 5 | 13 |
4 | 13 | 793.12 | 20 | 14.71 | 1436 | 422 | 3.02 / 17.57 | 5 | 21 |
5 | 13 | 207.96 | 20 | 14.91 | 572 | 171 | 3.19 / 17.74 | 5 | 15 |
6 | 13 | 96.92 | 20 | 14.95 | 400 | 120 | 3.31 / 17.86 | 5 | 12 |
7 | 8 | -0.08 | 287 | 14.94 | 247 | 1059 | 4.37 / 18.92 | 5 | 148 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 16 | 14.93 | 374 | 89 | 0.09 / 10.27 | 6 | 6 |
2 | 7 | 2005.52 | 40 | 14.53 | 3127 | 1817 | 1.91 / 12.09 | 6 | 10 |
3 | 13 | 1417.68 | 20 | 14.59 | 2320 | 677 | 2.58 / 12.77 | 5 | 15 |
4 | 13 | 864.60 | 20 | 14.69 | 1538 | 452 | 3.04 / 13.22 | 5 | 21 |
5 | 13 | 191.88 | 20 | 14.92 | 547 | 163 | 3.20 / 13.38 | 5 | 15 |
6 | 13 | 83.88 | 20 | 14.95 | 385 | 115 | 3.31 / 13.50 | 5 | 13 |
7 | 8 | 0.00 | 287 | 14.94 | 246 | 1055 | 4.37 / 14.55 | 5 | 146 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 13 | 14.91 | 369 | 72 | 0.07 / 5.84 | 6 | 6 |
2 | 10 | 1502.20 | 3 | 14.72 | 2398 | 106 | 0.18 / 5.94 | 5 | 6 |
3 | 7 | 2007.24 | 40 | 14.53 | 3124 | 1816 | 1.99 / 7.76 | 6 | 11 |
4 | 13 | 1440.24 | 20 | 14.58 | 2346 | 684 | 2.68 / 8.44 | 5 | 15 |
5 | 13 | 841.36 | 20 | 14.70 | 1507 | 443 | 3.12 / 8.89 | 5 | 22 |
6 | 13 | 186.64 | 20 | 14.92 | 538 | 161 | 3.28 / 9.05 | 5 | 14 |
7 | 13 | 74.92 | 20 | 14.95 | 362 | 108 | 3.39 / 9.16 | 5 | 12 |
8 | 8 | 0.04 | 285 | 14.94 | 241 | 1026 | 4.42 / 10.18 | 5 | 135 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.72 | 18 | 15.08 | 382 | 104 | 0.10 / 1.62 | 6 | 6 |
2 | 3 | 1369.48 | -2 | 15.34 | 0 | 0 | 0.00 / 1.62 | 6 | 6 |
3 | 7 | 2007.28 | 41 | 14.52 | 3115 | 1854 | 1.96 / 3.48 | 6 | 8 |
4 | 13 | 1287.80 | 20 | 14.60 | 2130 | 622 | 2.58 / 4.10 | 5 | 14 |
5 | 13 | 743.92 | 20 | 14.71 | 1357 | 399 | 2.98 / 4.50 | 5 | 21 |
6 | 13 | 173.92 | 20 | 14.90 | 510 | 152 | 3.13 / 4.65 | 5 | 14 |
7 | 13 | 65.16 | 20 | 14.93 | 346 | 103 | 3.23 / 4.76 | 5 | 12 |
8 | 8 | 0.08 | 287 | 14.92 | 236 | 1011 | 4.25 / 5.77 | 5 | 146 |
Average= | 2.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 122.76 | 18 | 15.25 | 396 | 109 | 0.11 / 0.11 | 6 | 6 |
2 | 7 | 136.52 | 40 | 15.22 | 416 | 253 | 0.36 / 0.36 | 6 | 6 |
3 | 13 | 148.64 | 20 | 15.20 | 431 | 131 | 0.49 / 0.49 | 6 | 6 |
4 | 13 | 88.28 | 20 | 15.19 | 341 | 104 | 0.60 / 0.60 | 6 | 6 |
5 | 8 | 0.08 | 289 | 15.16 | 211 | 924 | 1.52 / 1.52 | 6 | 151 |
Average= | 1.52 (KJ/cycle) |