SIO Argo Site:
Pump Diagnostics Page   



Serial= 7803 WMO= 4903540

Return

←PreviousNext→

Cycle 60 GMT 24/11/2024 3:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 26 14.87 719 278 0.28 / 388.33 4 5
2 7 2007.76 41 14.67 3851 2316 2.59 / 390.64 5 12
3 13 1157.52 20 14.77 2531 748 3.34 / 391.39 4 17
4 13 477.84 20 14.89 1461 435 3.78 / 391.83 4 17
5 13 23.08 20 15.01 613 184 3.96 / 392.01 4 13
6 8 0.08 306 14.91 534 2436 6.40 / 394.45 4 137
Average= 6.47
(KJ/cycle)

Cycle 59 GMT 13/11/2024 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 26 14.88 753 291 0.29 / 381.89 4 5
2 7 2009.64 40 14.66 3894 2283 2.57 / 384.18 5 13
3 13 1077.92 20 14.79 2389 707 3.28 / 384.88 4 20
4 13 519.88 20 14.89 1500 447 3.73 / 385.33 4 17
5 13 64.72 20 14.99 721 216 3.94 / 385.55 4 14
6 8 0.24 308 14.90 546 2506 6.45 / 388.05 4 137
Average= 6.47
(KJ/cycle)

Cycle 58 GMT 3/11/2024 14:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 26 14.88 729 282 0.28 / 375.26 4 5
2 7 2008.56 41 14.66 3919 2356 2.64 / 377.61 5 13
3 13 1155.12 20 14.77 2570 759 3.40 / 378.37 4 17
4 13 580.44 20 14.88 1590 473 3.87 / 378.85 4 18
5 13 38.88 20 15.01 681 204 4.07 / 379.05 4 14
6 8 0.00 306 14.91 559 2550 6.62 / 381.60 4 140
Average= 6.47
(KJ/cycle)

Cycle 57 GMT 24/10/2024 7:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 26 14.89 715 277 0.28 / 368.72 5 5
2 7 2008.40 40 14.67 3898 2287 2.56 / 371.01 14 14
3 13 1058.92 20 14.80 2393 708 3.27 / 371.72 4 20
4 13 497.36 20 14.91 1476 440 3.71 / 372.16 4 21
5 13 27.24 20 15.02 654 196 3.91 / 372.36 4 18
6 8 0.20 306 14.92 574 2621 6.53 / 374.98 4 136
Average= 6.47
(KJ/cycle)

Cycle 56 GMT 14/10/2024 0:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 26 14.90 760 294 0.29 / 362.06 4 5
2 7 2003.92 40 14.66 3957 2320 2.61 / 364.38 5 14
3 13 1136.84 20 14.79 2558 757 3.37 / 365.14 4 18
4 13 558.88 20 14.89 1612 480 3.85 / 365.62 4 21
5 13 39.24 20 15.02 710 213 4.06 / 365.83 4 20
6 8 0.08 306 14.92 572 2611 6.68 / 368.45 4 143
Average= 6.46
(KJ/cycle)

Cycle 55 GMT 3/10/2024 17:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 26 14.90 763 296 0.30 / 355.35 4 5
2 7 2002.68 40 14.67 3913 2296 2.59 / 357.65 5 11
3 13 1167.32 20 14.78 2591 766 3.36 / 358.41 4 20
4 13 586.00 20 14.89 1623 483 3.84 / 358.90 4 18
5 13 46.08 20 15.02 718 216 4.06 / 359.11 4 14
6 8 0.04 306 14.93 582 2659 6.72 / 361.77 4 134
Average= 6.46
(KJ/cycle)

Cycle 54 GMT 23/ 9/2024 11: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 26 14.92 734 285 0.28 / 348.74 4 5
2 7 2002.16 40 14.67 3913 2296 2.58 / 351.04 5 12
3 13 1055.20 20 14.81 2404 712 3.29 / 351.75 4 19
4 13 502.16 20 14.92 1485 443 3.74 / 352.19 4 19
5 13 56.16 20 15.03 711 214 3.95 / 352.40 4 16
6 8 0.12 306 14.93 580 2650 6.60 / 355.05 4 134
Average= 6.46
(KJ/cycle)

Cycle 53 GMT 13/ 9/2024 4:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 26 14.93 713 277 0.28 / 342.18 4 5
2 7 2002.96 40 14.69 3877 2278 2.55 / 344.46 5 11
3 13 1190.32 20 14.79 2617 774 3.33 / 345.24 4 16
4 13 514.28 20 14.93 1497 447 3.78 / 345.68 4 21
5 13 37.88 20 15.04 669 201 3.98 / 345.88 4 14
6 8 0.16 306 14.95 562 2571 6.55 / 348.45 4 142
Average= 6.45
(KJ/cycle)

Cycle 52 GMT 2/ 9/2024 21:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 25 14.92 775 289 0.29 / 335.57 4 5
2 7 2004.12 40 14.69 3918 2302 2.59 / 337.87 5 12
3 13 1074.68 20 14.81 2468 731 3.32 / 338.60 4 16
4 13 519.28 20 14.93 1542 460 3.78 / 339.06 4 22
5 13 35.48 20 15.05 697 210 3.99 / 339.27 4 17
6 8 0.12 306 14.95 576 2635 6.63 / 341.91 4 132
Average= 6.45
(KJ/cycle)

Cycle 51 GMT 23/ 8/2024 14:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 25 14.93 751 280 0.28 / 328.88 5 5
2 7 2006.64 40 14.69 3917 2302 2.58 / 331.18 11 13
3 13 1175.40 20 14.81 2601 770 3.35 / 331.95 4 16
4 13 493.16 20 14.95 1467 439 3.79 / 332.39 4 17
5 13 31.08 20 15.06 684 206 4.00 / 332.60 4 15
6 8 0.12 308 14.96 582 2682 6.68 / 335.28 4 144
Average= 6.45
(KJ/cycle)

Cycle 50 GMT 13/ 8/2024 7:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 25 14.94 747 279 0.28 / 322.20 4 5
2 7 2004.48 40 14.69 3919 2303 2.58 / 324.51 5 12
3 13 1087.16 20 14.83 2463 731 3.31 / 325.24 4 19
4 13 615.44 20 14.91 1705 508 3.82 / 325.74 4 24
5 13 47.36 20 15.06 711 214 4.03 / 325.96 4 16
6 8 0.12 306 14.96 577 2641 6.68 / 328.60 4 136
Average= 6.44
(KJ/cycle)

Cycle 49 GMT 3/ 8/2024 1: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 25 14.95 729 272 0.27 / 315.57 4 5
2 7 2010.20 40 14.69 3940 2315 2.59 / 317.88 5 13
3 13 968.16 20 14.86 2248 668 3.26 / 318.55 4 18
4 13 554.32 20 14.94 1569 469 3.72 / 319.02 4 21
5 13 31.36 20 15.07 686 207 3.93 / 319.23 4 17
6 8 0.16 306 14.96 589 2696 6.63 / 321.92 4 141
Average= 6.44
(KJ/cycle)

Cycle 48 GMT 23/ 7/2024 18: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 25 14.95 743 278 0.28 / 308.95 4 5
2 7 2004.48 40 14.70 3913 2301 2.58 / 311.26 5 13
3 13 1172.16 20 14.82 2573 763 3.34 / 312.02 4 20
4 13 672.12 20 14.91 1759 525 3.87 / 312.54 4 26
5 13 13.88 20 15.08 650 196 4.06 / 312.74 4 20
6 8 0.08 306 14.98 558 2558 6.62 / 315.30 4 138
Average= 6.43
(KJ/cycle)

Cycle 47 GMT 13/ 7/2024 11:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 26 14.96 734 285 0.29 / 302.16 4 5
2 7 2003.76 40 14.70 3925 2308 2.59 / 304.47 5 13
3 13 1282.68 20 14.78 2807 830 3.42 / 305.30 4 20
4 13 556.60 20 14.95 1568 469 3.89 / 305.76 4 20
5 13 16.20 20 15.09 666 201 4.09 / 305.97 4 17
6 8 0.04 306 14.97 592 2712 6.80 / 308.68 4 141
Average= 6.43
(KJ/cycle)

Cycle 46 GMT 3/ 7/2024 4:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 26 14.97 793 309 0.31 / 295.38 4 5
2 7 2002.36 40 14.69 3936 2313 2.62 / 297.69 5 12
3 13 1249.00 20 14.80 2742 812 3.43 / 298.50 4 19
4 13 649.84 20 14.93 1740 520 3.95 / 299.02 4 19
5 8 0.20 327 15.00 581 2850 6.80 / 301.87 4 144
Average= 6.42
(KJ/cycle)

Cycle 45 GMT 22/ 6/2024 22:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 26 14.97 740 288 0.29 / 288.85 4 5
2 7 2005.08 40 14.71 3924 2309 2.60 / 291.15 5 12
3 13 1060.48 20 14.87 2377 707 3.30 / 291.86 4 18
4 13 483.08 20 14.99 1444 433 3.74 / 292.29 4 20
5 8 0.20 325 15.01 569 2776 6.51 / 295.07 4 138
Average= 6.41
(KJ/cycle)

Cycle 44 GMT 12/ 6/2024 15:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 26 14.97 789 307 0.31 / 282.13 4 6
2 7 2013.72 40 14.71 3942 2319 2.63 / 284.45 6 14
3 13 1167.12 20 14.84 2584 767 3.39 / 285.21 4 21
4 13 588.00 20 14.96 1657 496 3.89 / 285.71 4 23
5 13 16.16 20 15.11 648 196 4.09 / 285.90 4 18
6 8 0.20 306 15.00 578 2653 6.74 / 288.56 4 138
Average= 6.41
(KJ/cycle)

Cycle 43 GMT 2/ 6/2024 8:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 26 14.98 764 298 0.30 / 275.43 4 5
2 7 2007.04 40 14.71 3933 2314 2.61 / 277.74 5 14
3 13 1151.56 20 14.86 2540 755 3.37 / 278.50 4 19
4 13 551.44 20 14.98 1545 463 3.83 / 278.96 4 17
5 8 0.16 325 15.01 586 2859 6.69 / 281.82 4 137
Average= 6.40
(KJ/cycle)

Cycle 42 GMT 23/ 5/2024 1:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 26 14.99 743 290 0.29 / 268.72 4 5
2 7 2002.64 40 14.73 3896 2296 2.59 / 271.02 5 13
3 13 1244.84 20 14.83 2705 802 3.39 / 271.82 4 20
4 13 628.32 20 14.96 1708 511 3.90 / 272.33 4 21
5 8 0.08 327 15.02 570 2800 6.70 / 275.13 4 146
Average= 6.40
(KJ/cycle)

Cycle 41 GMT 12/ 5/2024 19:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 26 14.99 774 302 0.30 / 262.09 4 5
2 7 2007.76 40 14.72 3919 2308 2.61 / 264.39 5 13
3 13 1153.72 20 14.86 2581 767 3.38 / 265.16 4 19
4 13 550.72 20 14.98 1601 480 3.86 / 265.64 4 17
5 8 0.16 323 15.03 575 2791 6.65 / 268.43 4 130
Average= 6.39
(KJ/cycle)

Cycle 40 GMT 2/ 5/2024 12:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 26 15.00 769 300 0.30 / 255.39 4 5
2 7 2005.36 40 14.73 3946 2325 2.62 / 257.72 5 14
3 13 1061.00 20 14.89 2427 723 3.35 / 258.44 4 17
4 13 716.40 20 14.94 1857 555 3.90 / 259.00 4 18
5 8 0.20 325 15.03 571 2789 6.69 / 261.79 4 134
Average= 6.39
(KJ/cycle)

Cycle 39 GMT 22/ 4/2024 5:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 26 15.02 729 285 0.28 / 248.91 4 6
2 7 2010.56 40 14.74 3896 2297 2.58 / 251.20 6 12
3 13 1086.56 20 14.89 2433 725 3.31 / 251.93 4 18
4 13 619.40 20 14.99 1652 495 3.80 / 252.42 4 22
5 8 0.08 325 15.05 546 2671 6.47 / 255.09 4 141
Average= 6.38
(KJ/cycle)

Cycle 38 GMT 11/ 4/2024 23: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 26 15.02 745 291 0.29 / 242.42 4 6
2 7 2004.40 40 14.75 3912 2308 2.60 / 244.73 6 12
3 13 1150.92 20 14.88 2548 758 3.36 / 245.49 4 17
4 13 578.48 20 15.00 1618 485 3.84 / 245.97 4 21
5 8 0.20 325 15.06 541 2648 6.49 / 248.62 4 135
Average= 6.37
(KJ/cycle)

Cycle 37 GMT 1/ 4/2024 16:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 25 15.01 723 271 0.27 / 235.95 4 6
2 7 2011.24 40 14.74 3905 2302 2.57 / 238.25 14 13
3 13 1146.56 20 14.88 2529 753 3.33 / 239.00 4 18
4 13 552.52 20 15.02 1510 454 3.78 / 239.46 4 21
5 8 0.12 325 15.06 546 2672 6.45 / 242.13 4 141
Average= 6.37
(KJ/cycle)

Cycle 36 GMT 22/ 3/2024 9:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 25 15.04 740 278 0.28 / 229.44 4 6
2 7 2005.28 40 14.75 3885 2292 2.57 / 231.73 6 12
3 13 1066.36 20 14.91 2419 721 3.29 / 232.45 4 17
4 13 699.28 20 14.97 1786 535 3.83 / 232.99 4 22
5 8 0.20 325 15.06 550 2692 6.52 / 235.68 4 143
Average= 6.37
(KJ/cycle)

Cycle 35 GMT 12/ 3/2024 2:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 25 15.05 713 268 0.27 / 223.04 4 6
2 7 2004.76 40 14.77 3867 2285 2.55 / 225.32 6 12
3 13 1162.20 20 14.90 2543 758 3.31 / 226.08 4 18
4 13 575.40 20 15.02 1571 472 3.78 / 226.55 4 18
5 8 0.12 323 15.08 535 2606 6.39 / 229.16 4 138
Average= 6.37
(KJ/cycle)

Cycle 34 GMT 1/ 3/2024 19:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 25 15.05 729 274 0.27 / 216.72 4 5
2 7 2008.00 40 14.76 3886 2294 2.57 / 219.01 5 13
3 13 1144.28 20 14.91 2503 746 3.31 / 219.76 4 17
4 13 555.28 20 15.04 1535 462 3.78 / 220.22 4 21
5 8 0.16 323 15.08 524 2552 6.33 / 222.77 4 147
Average= 6.36
(KJ/cycle)

Cycle 33 GMT 20/ 2/2024 13:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 25 15.04 786 296 0.30 / 210.22 4 6
2 7 2009.20 41 14.75 3927 2375 2.67 / 212.60 6 14
3 13 1142.52 20 14.91 2518 751 3.42 / 213.35 4 19
4 13 545.36 20 15.04 1515 456 3.88 / 213.80 4 19
5 8 0.32 323 15.08 542 2640 6.52 / 216.44 4 141
Average= 6.37
(KJ/cycle)

Cycle 32 GMT 10/ 2/2024 6:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 26 15.05 796 311 0.31 / 203.71 4 6
2 7 2008.64 40 14.76 3902 2304 2.62 / 206.01 6 14
3 13 1237.80 20 14.88 2703 804 3.42 / 206.82 4 22
4 13 413.36 20 15.09 1301 393 3.81 / 207.21 4 20
5 8 -0.08 323 15.09 557 2715 6.53 / 209.93 4 140
Average= 6.36
(KJ/cycle)

Cycle 31 GMT 30/ 1/2024 23:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 26 15.07 709 278 0.28 / 197.20 4 5
2 7 2006.16 40 14.78 3867 2286 2.56 / 199.49 5 15
3 13 1139.44 20 14.93 2480 741 3.30 / 200.23 4 16
4 13 556.68 20 15.06 1512 455 3.76 / 200.69 4 21
5 8 0.08 325 15.09 553 2712 6.47 / 203.40 4 146
Average= 6.36
(KJ/cycle)

Cycle 30 GMT 20/ 1/2024 17:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 26 15.08 720 282 0.28 / 190.81 4 5
2 7 2007.56 40 14.78 3872 2289 2.57 / 193.10 5 14
3 13 1147.76 20 14.93 2517 752 3.32 / 193.85 4 16
4 13 559.80 20 15.05 1536 462 3.79 / 194.31 4 20
5 8 0.24 325 15.10 533 2616 6.40 / 196.93 4 150
Average= 6.35
(KJ/cycle)

Cycle 29 GMT 10/ 1/2024 10:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 26 15.06 718 281 0.28 / 184.23 4 6
2 7 2005.92 40 14.79 3886 2299 2.58 / 186.53 6 13
3 13 1166.80 20 14.92 2581 770 3.35 / 187.30 4 18
4 13 575.72 20 15.05 1583 476 3.83 / 187.78 4 23
5 8 0.12 325 15.10 560 2748 6.57 / 190.53 4 144
Average= 6.35
(KJ/cycle)

Cycle 28 GMT 31/12/2023 4: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 26 15.08 712 279 0.28 / 177.78 4 5
2 7 2006.88 40 14.78 3894 2302 2.58 / 180.08 5 12
3 13 1162.48 20 14.93 2565 766 3.35 / 180.85 4 21
4 13 547.12 20 15.07 1518 458 3.80 / 181.31 4 20
5 8 0.00 323 15.11 542 2645 6.45 / 183.95 4 138
Average= 6.34
(KJ/cycle)

Cycle 27 GMT 20/12/2023 21:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 25 15.09 717 270 0.27 / 171.27 4 5
2 7 2009.68 40 14.78 3888 2299 2.57 / 173.56 5 14
3 13 1160.56 20 14.93 2567 767 3.34 / 174.33 4 20
4 13 578.16 20 15.06 1591 479 3.81 / 174.81 4 20
5 8 0.32 325 15.11 548 2691 6.51 / 177.50 4 138
Average= 6.34
(KJ/cycle)

Cycle 26 GMT 10/12/2023 14:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 19 15.06 704 201 0.20 / 164.49 4 5
2 10 1061.04 6 15.07 2299 208 0.41 / 164.70 4 10
3 3 1041.84 1 15.18 2338 35 0.44 / 164.73 4 13
4 7 2005.20 41 14.78 3881 2352 2.80 / 167.08 13 12
5 13 1156.52 20 14.94 2524 754 3.55 / 167.84 4 20
6 13 568.72 20 15.06 1570 473 4.02 / 168.31 4 19
7 8 0.40 323 15.11 550 2684 6.71 / 170.99 4 138
Average= 6.33
(KJ/cycle)

Cycle 25 GMT 30/11/2023 7:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 45 15.08 711 482 0.48 / 158.10 4 6
2 3 288.80 -11 15.52 0 0 0.00 / 158.10 4 6
3 7 2003.92 40 14.80 3869 2290 2.77 / 160.39 6 14
4 13 1149.12 20 14.93 2522 753 3.53 / 161.14 4 18
5 13 550.16 20 15.06 1532 461 3.99 / 161.60 4 22
6 13 31.88 20 15.19 641 195 4.18 / 161.80 4 18
7 8 -0.08 304 15.09 543 2491 6.67 / 164.29 4 129
Average= 6.32
(KJ/cycle)

Cycle 24 GMT 20/11/2023 0:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 41 15.09 682 422 0.42 / 150.72 4 5
2 10 1034.24 3 15.19 2250 103 0.52 / 150.83 4 11
3 5 1333.60 8 15.12 2749 333 0.86 / 151.16 4 15
4 5 1345.36 8 15.11 2762 334 1.19 / 151.49 4 12
5 7 2008.76 40 14.80 3850 2279 3.47 / 153.77 12 12
6 13 1169.68 20 14.95 2543 760 4.23 / 154.53 4 18
7 13 591.68 20 15.08 1560 470 4.70 / 155.00 4 20
8 13 45.36 20 15.21 615 187 4.89 / 155.19 4 17
9 8 0.00 304 15.13 527 2424 7.31 / 157.61 4 139
Average= 6.30
(KJ/cycle)

Cycle 23 GMT 9/11/2023 17:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 49 15.09 664 491 0.49 / 144.31 4 6
2 3 751.76 -4 15.52 0 0 0.00 / 144.31 4 6
3 7 2004.48 40 14.80 3827 2266 2.76 / 146.58 6 13
4 13 1069.52 20 14.98 2348 703 3.46 / 147.28 4 17
5 13 608.44 20 15.07 1603 483 3.94 / 147.76 4 22
6 13 39.64 20 15.22 613 187 4.13 / 147.95 4 17
7 8 0.24 304 15.13 511 2350 6.48 / 150.30 4 140
Average= 6.26
(KJ/cycle)

Cycle 22 GMT 30/10/2023 10:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 53 15.11 666 533 0.53 / 137.71 4 5
2 3 779.80 -3 15.53 0 0 0.00 / 137.71 4 5
3 7 2002.60 40 14.81 3837 2273 2.81 / 139.98 5 14
4 13 1168.92 20 14.96 2509 751 3.56 / 140.73 4 20
5 13 589.80 20 15.09 1553 469 4.03 / 141.20 4 22
6 13 53.00 20 15.21 653 199 4.22 / 141.40 4 17
7 8 0.08 308 15.14 519 2420 6.64 / 143.82 4 140
Average= 6.25
(KJ/cycle)

Cycle 21 GMT 20/10/2023 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 32 15.13 701 339 0.34 / 128.35 4 5
2 10 1057.12 6 15.12 2273 206 0.55 / 128.56 4 10
3 10 1137.20 4 15.12 2414 146 0.69 / 128.70 4 9
4 10 1310.88 3 15.11 2747 125 0.82 / 128.83 4 12
5 3 1311.24 8 15.04 2765 333 1.15 / 129.16 4 11
6 5 1471.40 12 15.00 3023 544 1.69 / 129.71 4 14
7 5 1356.08 9 15.08 2846 386 2.08 / 130.09 4 13
8 5 1333.44 8 15.13 2800 339 2.42 / 130.43 4 15
9 5 1317.28 8 15.14 2784 337 2.76 / 130.77 4 13
10 5 1452.84 11 15.04 2998 496 3.25 / 131.26 4 13
11 7 2004.44 40 14.80 3876 2295 5.55 / 133.56 13 13
12 13 1038.64 20 15.00 2327 698 6.24 / 134.26 4 21
13 13 460.72 20 15.14 1342 406 6.65 / 134.66 4 18
14 13 46.88 20 15.23 631 192 6.84 / 134.86 4 17
15 8 0.16 304 15.15 504 2321 9.16 / 137.18 4 143
Average= 6.24
(KJ/cycle)

Cycle 20 GMT 9/10/2023 21:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 25 15.13 695 263 0.26 / 118.25 4 5
2 3 1191.84 5 15.14 2529 191 0.45 / 118.44 4 12
3 5 1354.16 9 15.08 2796 379 0.83 / 118.82 4 14
4 5 1380.08 9 15.08 2853 387 1.22 / 119.21 4 14
5 5 1479.60 12 15.04 3018 545 1.77 / 119.75 4 13
6 5 1365.80 9 15.07 2852 387 2.15 / 120.14 4 13
7 5 1306.60 8 15.09 2737 330 2.48 / 120.47 4 12
8 5 1302.36 7 15.13 2687 285 2.77 / 120.75 4 14
9 5 1369.92 9 15.09 2785 378 3.15 / 121.13 4 12
10 5 1311.56 8 15.10 2705 327 3.47 / 121.46 4 14
11 5 1330.96 8 15.11 2780 336 3.81 / 121.79 4 14
12 7 2002.92 40 14.81 3847 2279 6.09 / 124.07 14 15
13 13 1372.04 20 14.92 2857 853 6.94 / 124.93 4 18
14 13 666.20 20 15.08 1706 515 7.45 / 125.44 4 23
15 13 91.28 20 15.22 731 223 7.68 / 125.66 4 17
16 8 0.12 312 15.16 497 2351 10.03 / 128.01 4 149
Average= 6.10
(KJ/cycle)

Cycle 19 GMT 29/ 9/2023 14:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 46 15.12 664 462 0.46 / 111.32 4 6
2 3 341.00 -10 15.54 0 0 0.00 / 111.32 4 6
3 5 1491.68 12 15.07 3019 546 1.01 / 111.87 4 12
4 7 2004.52 41 14.82 3829 2327 3.33 / 114.19 12 14
5 13 1156.24 20 14.97 2521 755 4.09 / 114.95 4 19
6 13 566.56 20 15.10 1534 463 4.55 / 115.41 4 20
7 13 41.12 20 15.24 622 190 4.74 / 115.60 4 19
8 8 0.16 306 15.15 514 2383 7.12 / 117.99 4 141
Average= 5.90
(KJ/cycle)

Cycle 18 GMT 19/ 9/2023 8:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 43 15.12 672 437 0.44 / 104.44 4 5
2 10 1003.08 3 15.21 2249 103 0.54 / 104.55 4 15
3 7 2002.92 41 14.81 3858 2343 2.88 / 106.89 15 13
4 13 1301.08 20 14.92 2796 834 3.72 / 107.72 4 18
5 13 718.60 20 15.06 1802 543 4.26 / 108.27 4 18
6 13 136.20 20 15.21 792 241 4.50 / 108.51 4 18
7 8 0.24 310 15.16 501 2354 6.85 / 110.86 4 136
Average= 5.83
(KJ/cycle)

Cycle 17 GMT 9/ 9/2023 1:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 46 15.12 670 466 0.47 / 97.94 4 5
2 3 896.00 -2 15.54 0 0 0.00 / 97.94 4 5
3 7 2001.76 40 14.83 3824 2268 2.73 / 100.21 5 15
4 13 1151.44 20 14.99 2507 752 3.49 / 100.96 4 19
5 13 555.64 20 15.12 1532 463 3.95 / 101.43 4 19
6 13 35.92 20 15.24 620 189 4.14 / 101.61 4 18
7 8 0.04 304 15.16 519 2392 6.53 / 104.01 4 143
Average= 5.78
(KJ/cycle)

Cycle 16 GMT 29/ 8/2023 18:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 35 15.13 689 365 0.36 / 90.96 5 5
2 10 1046.92 3 15.18 2297 105 0.47 / 91.07 4 11
3 10 1108.72 3 15.18 2368 108 0.58 / 91.18 4 10
4 3 1199.52 5 15.16 2528 192 0.77 / 91.37 4 11
5 7 2001.80 40 14.83 3838 2277 3.05 / 93.65 11 13
6 13 1144.00 20 14.99 2504 751 3.80 / 94.40 4 21
7 13 579.36 20 15.11 1581 478 4.27 / 94.87 4 22
8 13 39.48 20 15.24 653 199 4.47 / 95.07 4 18
9 8 0.16 306 15.16 518 2403 6.88 / 97.48 4 135
Average= 5.73
(KJ/cycle)

Cycle 15 GMT 19/ 8/2023 12:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 44 15.13 701 467 0.47 / 84.71 4 6
2 3 734.84 -4 15.54 0 0 0.00 / 84.71 4 6
3 7 2003.20 40 14.84 3815 2265 2.73 / 86.98 6 14
4 13 1048.92 20 15.02 2321 697 3.43 / 87.68 4 20
5 13 471.36 20 15.14 1396 423 3.85 / 88.10 4 19
6 13 22.84 20 15.25 614 187 4.04 / 88.29 4 17
7 8 0.20 302 15.17 505 2314 6.35 / 90.60 4 134
Average= 5.66
(KJ/cycle)

Cycle 14 GMT 9/ 8/2023 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 27 15.15 724 296 0.30 / 77.34 4 5
2 10 1002.60 6 15.15 2178 198 0.49 / 77.54 4 8
3 10 1120.44 3 15.17 2391 109 0.60 / 77.65 4 8
4 10 1212.08 3 15.14 2567 117 0.72 / 77.76 4 10
5 3 1287.76 7 15.11 2662 282 1.00 / 78.04 4 11
6 7 2002.52 40 14.85 3831 2276 3.28 / 80.32 11 13
7 13 1253.72 20 14.97 2673 800 4.08 / 81.12 4 20
8 13 618.32 20 15.11 1624 491 4.57 / 81.61 4 21
9 13 40.16 20 15.25 631 192 4.76 / 81.80 4 18
10 8 0.08 304 15.17 530 2444 7.20 / 84.25 4 142
Average= 5.62
(KJ/cycle)

Cycle 13 GMT 29/ 7/2023 22:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 39 15.14 711 420 0.42 / 70.99 4 5
2 3 649.52 -5 15.55 0 0 0.00 / 70.99 4 5
3 7 2003.68 40 14.85 3795 2254 2.67 / 73.24 5 14
4 13 1136.60 20 15.01 2447 735 3.41 / 73.98 4 20
5 13 439.48 20 15.17 1312 398 3.81 / 74.37 4 17
6 13 32.44 20 15.26 608 186 3.99 / 74.56 4 17
7 8 0.16 302 15.17 542 2483 6.48 / 77.04 4 132
Average= 5.50
(KJ/cycle)

Cycle 12 GMT 19/ 7/2023 15:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 31 15.15 753 354 0.35 / 63.08 4 5
2 10 1053.52 4 15.18 2260 137 0.49 / 63.21 4 9
3 3 1133.36 3 15.20 2408 110 0.60 / 63.32 4 12
4 5 1363.92 9 15.14 2785 379 0.98 / 63.70 4 13
5 5 1320.84 8 15.19 2712 330 1.31 / 64.03 4 12
6 5 1537.24 13 15.06 3032 594 1.90 / 64.63 4 14
7 7 2002.28 40 14.85 3793 2253 4.16 / 66.88 14 14
8 13 1038.36 20 15.05 2265 682 4.84 / 67.56 4 19
9 13 477.76 20 15.17 1342 407 5.25 / 67.97 4 19
10 13 22.24 20 15.27 562 172 5.42 / 68.14 4 18
11 8 0.12 304 15.18 526 2427 7.84 / 70.57 4 144
Average= 5.43
(KJ/cycle)

Cycle 11 GMT 9/ 7/2023 8:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 25 15.15 749 284 0.28 / 56.41 4 5
2 10 1045.32 6 15.15 2266 206 0.49 / 56.62 4 9
3 3 1027.88 1 15.24 2325 35 0.53 / 56.65 4 11
4 7 2008.16 40 14.87 3803 2262 2.79 / 58.91 11 15
5 13 1071.32 20 15.04 2339 704 3.49 / 59.62 4 20
6 13 485.72 20 15.16 1377 418 3.91 / 60.03 4 18
7 13 25.84 20 15.27 570 174 4.08 / 60.21 4 17
8 8 0.08 304 15.18 545 2515 6.60 / 62.72 4 138
Average= 5.23
(KJ/cycle)

Cycle 10 GMT 29/ 6/2023 2:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 27 15.16 732 300 0.30 / 50.16 4 5
2 3 963.04 -1 15.55 0 0 0.00 / 50.16 4 5
3 7 2003.04 40 14.86 3777 2245 2.54 / 52.41 5 13
4 13 1035.64 20 15.05 2294 690 3.24 / 53.10 4 18
5 13 371.52 20 15.20 1162 353 3.59 / 53.45 4 20
6 8 0.24 323 15.19 545 2674 6.26 / 56.13 4 134
Average= 5.10
(KJ/cycle)

Cycle 9 GMT 18/ 6/2023 19:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 25 15.16 773 293 0.29 / 43.79 4 5
2 3 1049.64 1 15.25 2277 35 0.33 / 43.82 4 10
3 7 2003.52 40 14.87 3781 2249 2.58 / 46.07 10 15
4 13 1049.36 20 15.05 2283 687 3.26 / 46.76 4 21
5 13 566.44 20 15.15 1514 459 3.72 / 47.22 4 20
6 13 12.56 20 15.28 551 168 3.89 / 47.38 4 19
7 8 0.20 302 15.18 541 2480 6.37 / 49.86 4 132
Average= 4.99
(KJ/cycle)

Cycle 8 GMT 8/ 6/2023 12:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 25 15.18 693 263 0.26 / 37.53 4 5
2 7 2006.24 40 14.88 3782 2251 2.51 / 39.78 5 14
3 13 1065.28 20 15.05 2301 693 3.21 / 40.47 4 20
4 13 492.84 20 15.18 1341 407 3.61 / 40.88 4 19
5 8 0.16 323 15.20 532 2612 6.23 / 43.49 4 140
Average= 4.83
(KJ/cycle)

Cycle 7 GMT 29/ 5/2023 5:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 24 15.19 679 248 0.25 / 31.48 4 5
2 3 1038.08 1 15.27 2191 33 0.28 / 31.51 4 10
3 7 2008.56 40 14.89 3719 2215 2.50 / 33.73 10 11
4 13 1071.32 20 15.07 2248 678 3.17 / 34.41 4 15
5 13 493.60 20 15.19 1318 400 3.57 / 34.81 4 17
6 8 -0.12 323 15.21 501 2461 6.04 / 37.27 4 146
Average= 4.66
(KJ/cycle)

Cycle 6 GMT 18/ 5/2023 23:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 22 15.20 626 209 0.21 / 25.58 4 5
2 3 1097.28 2 15.24 2290 70 0.28 / 25.65 4 10
3 7 2003.28 40 14.90 3706 2209 2.49 / 27.86 10 12
4 13 1150.24 20 15.05 2361 711 3.20 / 28.57 4 18
5 13 438.92 20 15.21 1201 365 3.56 / 28.93 4 19
6 8 0.20 323 15.22 468 2301 5.86 / 31.23 4 149
Average= 4.46
(KJ/cycle)

Cycle 5 GMT 8/ 5/2023 16:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 31 15.21 640 302 0.30 / 19.87 4 6
2 3 745.64 -4 15.56 0 0 0.00 / 19.87 4 6
3 7 2005.32 40 14.90 3698 2204 2.51 / 22.08 6 13
4 13 1056.68 20 15.08 2198 663 3.17 / 22.74 4 19
5 13 582.36 20 15.17 1424 432 3.60 / 23.17 4 19
6 13 12.84 20 15.31 436 134 3.73 / 23.31 4 18
7 8 0.16 302 15.23 448 2061 5.79 / 25.37 4 141
Average= 4.23
(KJ/cycle)

Cycle 4 GMT 28/ 4/2023 8:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 22 15.22 594 199 0.20 / 14.80 4 5
2 10 1007.88 3 15.22 2052 94 0.29 / 14.89 4 8
3 7 1514.44 40 15.11 2878 1739 2.03 / 16.63 8 10
4 13 843.88 20 15.18 1832 556 2.59 / 17.19 4 15
5 13 287.24 20 15.27 918 280 2.87 / 17.47 4 16
6 8 0.08 319 15.25 433 2106 4.98 / 19.57 4 147
Average= 3.91
(KJ/cycle)

Cycle 3 GMT 26/ 4/2023 23:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 21 15.22 590 189 0.19 / 9.88 4 6
2 10 1015.92 3 15.23 2029 93 0.28 / 9.97 4 7
3 3 961.00 -1 15.55 0 0 0.09 / 9.97 4 7
4 7 1512.72 40 15.12 2834 1714 2.00 / 11.68 7 11
5 13 972.20 20 15.16 2023 613 2.61 / 12.30 4 14
6 13 275.96 20 15.28 886 271 2.88 / 12.57 4 15
7 8 0.12 319 15.26 417 2030 4.91 / 14.60 4 144
Average= 3.65
(KJ/cycle)

Cycle 2 GMT 25/ 4/2023 13:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 31 15.25 575 272 0.27 / 5.27 4 5
2 3 725.60 -4 15.56 0 0 0.00 / 5.27 4 5
3 7 1447.32 41 15.14 2712 1683 1.96 / 6.95 5 9
4 13 893.08 20 15.18 1848 561 2.52 / 7.51 4 14
5 13 203.52 20 15.30 704 215 2.73 / 7.73 4 17
6 8 0.12 317 15.26 405 1959 4.69 / 9.69 4 135
Average= 3.23
(KJ/cycle)

Cycle 1 GMT 24/ 4/2023 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 31 15.45 490 235 0.23 / 2.21 5 5
2 3 750.64 -4 15.58 0 0 0.00 / 2.21 5 5
3 7 812.36 41 15.27 1691 1059 1.29 / 3.27 5 12
4 8 0.16 323 15.32 350 1732 3.03 / 5.00 4 134
Average= 2.50
(KJ/cycle)

Cycle 0 GMT 23/ 4/2023 17:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 96.12 30 15.60 481 225 0.23 / 0.23 5 8
2 7 106.68 40 15.59 480 299 0.52 / 0.52 8 10
3 8 0.16 317 15.53 294 1447 1.97 / 1.97 5 132
Average= 1.97
(KJ/cycle)