SIO Argo Site:
Pump Diagnostics Page   



Serial= 7709 WMO= 4903481

Return

←PreviousNext→

Cycle 78 GMT 23/12/2024 13:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 29 14.97 501 217 0.22 / 416.55 5 6
2 7 2004.20 40 14.71 3565 2098 2.32 / 418.65 6 24
3 13 1261.64 20 14.77 2453 725 3.04 / 419.38 4 32
4 13 655.64 20 14.86 1490 443 3.48 / 419.82 4 36
5 13 33.04 20 15.04 445 134 3.62 / 419.95 5 32
6 8 0.08 317 14.97 370 1756 5.37 / 421.71 5 150
Average= 5.34
(KJ/cycle)

Cycle 77 GMT 13/12/2024 6:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 28 14.98 507 213 0.21 / 411.24 5 5
2 7 2004.44 40 14.71 3571 2101 2.31 / 413.34 19 24
3 13 1174.52 20 14.79 2318 686 3.00 / 414.03 4 31
4 13 696.92 20 14.85 1561 464 3.46 / 414.49 4 36
5 13 39.32 20 15.04 450 135 3.60 / 414.62 4 31
6 8 0.00 317 14.97 361 1713 5.31 / 416.34 5 138
Average= 5.34
(KJ/cycle)

Cycle 76 GMT 3/12/2024 0:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 28 14.97 504 211 0.21 / 405.89 5 6
2 7 2006.48 40 14.71 3587 2111 2.32 / 408.00 6 22
3 13 1271.92 20 14.77 2470 730 3.05 / 408.73 4 32
4 13 660.72 20 14.87 1506 448 3.50 / 409.17 4 37
5 13 31.60 20 15.04 434 131 3.63 / 409.31 5 32
6 8 0.00 319 14.98 360 1720 5.35 / 411.03 5 143
Average= 5.34
(KJ/cycle)

Cycle 75 GMT 22/11/2024 17:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 28 14.98 525 220 0.22 / 400.57 5 6
2 7 2005.60 40 14.72 3579 2107 2.33 / 402.68 6 23
3 13 1179.76 20 14.79 2333 690 3.02 / 403.37 4 32
4 13 701.32 20 14.86 1568 466 3.48 / 403.84 4 36
5 13 41.20 20 15.04 452 136 3.62 / 403.97 5 33
6 8 0.04 314 14.98 362 1703 5.32 / 405.68 5 129
Average= 5.34
(KJ/cycle)

Cycle 74 GMT 12/11/2024 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 28 14.99 520 218 0.22 / 395.26 5 6
2 7 2003.32 40 14.71 3579 2106 2.32 / 397.36 11 24
3 13 1183.16 20 14.79 2327 688 3.01 / 398.05 4 33
4 13 626.96 20 14.88 1449 431 3.44 / 398.48 4 35
5 13 27.48 20 15.05 429 129 3.57 / 398.61 5 31
6 13 9.60 20 15.04 399 120 3.69 / 398.73 5 30
7 8 0.00 297 14.97 365 1623 5.32 / 400.35 5 142
Average= 5.34
(KJ/cycle)

Cycle 73 GMT 2/11/2024 4:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 29 14.98 514 223 0.22 / 389.95 5 6
2 7 2009.24 41 14.72 3587 2165 2.39 / 392.12 6 24
3 13 1156.76 20 14.80 2292 678 3.07 / 392.80 4 33
4 13 587.08 20 14.89 1385 412 3.48 / 393.21 4 36
5 13 35.24 20 15.05 435 131 3.61 / 393.34 5 32
6 13 12.60 20 15.05 394 119 3.73 / 393.46 5 31
7 8 0.00 293 14.98 360 1580 5.31 / 395.04 5 137
Average= 5.34
(KJ/cycle)

Cycle 72 GMT 22/10/2024 22:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 28 14.99 513 215 0.22 / 384.70 5 6
2 7 2002.08 40 14.72 3568 2101 2.32 / 386.80 6 24
3 13 1230.32 20 14.80 2393 708 3.02 / 387.51 4 33
4 13 527.32 20 14.92 1287 384 3.41 / 387.89 4 36
5 13 23.96 20 15.06 420 127 3.54 / 388.02 5 31
6 8 0.04 314 14.99 363 1709 5.24 / 389.73 5 130
Average= 5.34
(KJ/cycle)

Cycle 71 GMT 12/10/2024 16: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 28 14.98 506 212 0.21 / 379.48 5 6
2 7 2002.16 40 14.72 3570 2102 2.31 / 381.58 6 24
3 13 1168.60 20 14.80 2312 684 3.00 / 382.26 4 33
4 13 495.68 20 14.93 1238 370 3.37 / 382.63 4 36
5 13 27.08 20 15.06 427 129 3.50 / 382.76 5 30
6 8 0.08 314 14.99 366 1723 5.22 / 384.49 5 135
Average= 5.34
(KJ/cycle)

Cycle 70 GMT 2/10/2024 9:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 29 15.00 508 221 0.22 / 374.19 5 5
2 7 1936.64 40 14.73 3473 2046 2.27 / 376.24 5 25
3 13 1206.80 20 14.80 2363 699 2.97 / 376.94 4 33
4 13 601.36 20 14.90 1414 421 3.39 / 377.36 4 38
5 13 40.80 20 15.05 459 138 3.53 / 377.50 5 34
6 8 0.04 319 14.99 370 1769 5.30 / 379.27 5 152
Average= 5.34
(KJ/cycle)

Cycle 69 GMT 21/ 9/2024 23: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 28 15.01 503 211 0.21 / 368.82 5 5
2 10 1004.56 3 15.03 2030 92 0.30 / 368.91 4 20
3 3 914.44 -1 15.40 0 0 0.09 / 368.91 4 20
4 7 2002.28 40 14.73 3575 2106 2.41 / 371.02 20 22
5 13 1168.84 20 14.81 2305 683 3.09 / 371.70 4 32
6 13 612.76 20 14.90 1422 424 3.52 / 372.12 4 36
7 13 26.80 20 15.07 428 129 3.64 / 372.25 5 31
8 8 0.00 314 15.00 365 1719 5.36 / 373.97 5 135
Average= 5.34
(KJ/cycle)

Cycle 68 GMT 11/ 9/2024 16:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 28 15.01 517 217 0.22 / 363.55 5 6
2 7 2007.60 41 14.72 3574 2157 2.37 / 365.71 6 24
3 13 1170.80 20 14.81 2307 683 3.06 / 366.39 4 33
4 13 495.80 20 14.94 1244 372 3.43 / 366.77 4 36
5 13 31.72 20 15.07 438 132 3.56 / 366.90 5 33
6 8 0.00 310 15.01 367 1708 5.27 / 368.61 5 134
Average= 5.34
(KJ/cycle)

Cycle 67 GMT 1/ 9/2024 9:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 28 15.01 506 213 0.21 / 358.30 5 6
2 7 2008.96 40 14.73 3582 2111 2.32 / 360.41 6 25
3 13 1173.08 20 14.81 2310 684 3.01 / 361.09 4 32
4 13 609.16 20 14.91 1417 423 3.43 / 361.51 4 36
5 13 24.56 20 15.08 418 126 3.56 / 361.64 5 31
6 8 0.08 314 15.01 360 1697 5.25 / 363.34 5 131
Average= 5.34
(KJ/cycle)

Cycle 66 GMT 22/ 8/2024 2:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 28 15.02 507 213 0.21 / 353.02 5 6
2 7 2007.16 40 14.73 3579 2109 2.32 / 355.13 6 23
3 13 1177.00 20 14.81 2315 686 3.01 / 355.81 4 32
4 13 598.92 20 14.91 1404 419 3.43 / 356.23 4 36
5 13 37.56 20 15.08 438 132 3.56 / 356.36 5 32
6 13 10.92 20 15.08 397 120 3.68 / 356.48 5 29
7 8 -0.12 295 15.01 362 1603 5.28 / 358.08 5 149
Average= 5.34
(KJ/cycle)

Cycle 65 GMT 11/ 8/2024 19:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 28 15.02 504 212 0.21 / 347.76 5 6
2 7 2004.52 40 14.74 3567 2103 2.32 / 349.87 6 24
3 13 1266.52 20 14.80 2459 728 3.04 / 350.59 4 31
4 13 574.12 20 14.93 1362 407 3.45 / 351.00 4 36
5 13 47.96 20 15.08 455 137 3.59 / 351.14 5 32
6 13 28.20 20 15.08 419 126 3.71 / 351.26 5 32
7 8 0.04 287 15.02 357 1539 5.25 / 352.80 5 133
Average= 5.35
(KJ/cycle)

Cycle 64 GMT 1/ 8/2024 13:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 28 15.03 507 213 0.21 / 342.49 5 6
2 7 2002.96 40 14.74 3576 2108 2.32 / 344.60 6 23
3 13 1269.80 20 14.80 2455 727 3.05 / 345.33 4 31
4 13 585.08 20 14.93 1372 410 3.46 / 345.74 4 36
5 13 48.84 20 15.09 464 140 3.60 / 345.88 5 32
6 13 28.48 20 15.08 429 129 3.73 / 346.01 5 32
7 8 -0.08 287 15.03 358 1544 5.27 / 347.55 5 140
Average= 5.35
(KJ/cycle)

Cycle 63 GMT 22/ 7/2024 6:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 28 15.03 520 219 0.22 / 337.32 5 6
2 7 2008.08 40 14.73 3569 2103 2.32 / 339.42 6 24
3 13 1169.48 20 14.82 2307 684 3.01 / 340.10 4 33
4 13 590.68 20 14.93 1386 414 3.42 / 340.52 4 36
5 13 47.48 20 15.09 456 138 3.56 / 340.65 5 32
6 13 30.84 20 15.08 427 129 3.69 / 340.78 5 32
7 8 0.08 282 15.03 353 1496 5.18 / 342.28 5 136
Average= 5.35
(KJ/cycle)

Cycle 62 GMT 12/ 7/2024 0: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 28 15.04 493 208 0.21 / 332.09 5 6
2 7 2004.12 40 14.73 3571 2104 2.31 / 334.19 6 24
3 13 1148.92 20 14.84 2268 673 2.98 / 334.87 4 33
4 13 574.88 20 14.94 1361 407 3.39 / 335.27 4 36
5 13 39.24 20 15.10 450 136 3.53 / 335.41 5 32
6 13 17.16 20 15.10 407 123 3.65 / 335.53 5 30
7 8 -0.12 287 15.03 363 1566 5.22 / 337.10 5 158
Average= 5.35
(KJ/cycle)

Cycle 61 GMT 1/ 7/2024 17:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 28 15.04 499 210 0.21 / 326.81 5 6
2 7 2007.56 40 14.74 3576 2108 2.32 / 328.92 6 24
3 13 1269.80 20 14.81 2462 729 3.05 / 329.65 4 33
4 13 574.16 20 14.95 1365 408 3.46 / 330.06 4 36
5 13 42.44 20 15.11 450 136 3.59 / 330.19 5 32
6 13 12.04 20 15.11 395 119 3.71 / 330.31 5 30
7 8 0.04 289 15.04 361 1569 5.28 / 331.88 5 135
Average= 5.35
(KJ/cycle)

Cycle 60 GMT 21/ 6/2024 10:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 28 15.05 505 213 0.21 / 321.51 5 6
2 7 2003.04 40 14.75 3561 2101 2.31 / 323.62 6 23
3 13 1171.72 20 14.84 2312 686 3.00 / 324.30 4 33
4 13 695.76 20 14.91 1565 467 3.47 / 324.77 4 37
5 13 42.08 20 15.11 450 136 3.60 / 324.90 5 32
6 8 0.12 310 15.04 364 1697 5.30 / 326.60 5 139
Average= 5.35
(KJ/cycle)

Cycle 59 GMT 11/ 6/2024 4:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 28 15.05 513 216 0.22 / 316.26 5 6
2 7 2002.60 40 14.75 3564 2103 2.32 / 318.36 6 24
3 13 1229.04 20 14.83 2396 711 3.03 / 319.07 4 33
4 13 527.72 20 14.97 1287 385 3.41 / 319.46 4 36
5 13 66.44 20 15.10 498 150 3.57 / 319.61 4 33
6 8 0.00 310 15.05 363 1694 5.26 / 321.30 5 137
Average= 5.36
(KJ/cycle)

Cycle 58 GMT 31/ 5/2024 21:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 28 15.06 497 210 0.21 / 311.04 5 6
2 7 2003.36 40 14.75 3568 2105 2.31 / 313.14 6 24
3 13 1151.48 20 14.85 2281 677 2.99 / 313.82 4 33
4 13 571.04 20 14.96 1356 406 3.40 / 314.23 4 37
5 13 37.96 20 15.12 444 134 3.53 / 314.36 5 32
6 13 13.76 20 15.12 394 119 3.65 / 314.48 5 32
7 8 0.04 291 15.05 357 1563 5.21 / 316.04 5 154
Average= 5.36
(KJ/cycle)

Cycle 57 GMT 21/ 5/2024 15:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 28 15.06 506 213 0.21 / 305.75 5 6
2 7 2004.48 40 14.75 3577 2110 2.32 / 307.86 6 24
3 13 1274.16 20 14.83 2476 734 3.06 / 308.59 4 32
4 13 584.04 20 14.97 1385 415 3.47 / 309.01 4 36
5 13 45.72 20 15.12 457 138 3.61 / 309.15 5 33
6 13 13.12 20 15.12 396 120 3.73 / 309.27 5 31
7 8 0.04 289 15.06 359 1562 5.29 / 310.83 5 133
Average= 5.36
(KJ/cycle)

Cycle 56 GMT 11/ 5/2024 8:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 28 15.06 531 224 0.22 / 300.39 5 6
2 7 2003.84 40 14.76 3569 2107 2.33 / 302.50 6 25
3 13 1267.72 20 14.83 2456 728 3.06 / 303.23 4 31
4 13 674.76 20 14.95 1526 456 3.52 / 303.69 4 36
5 13 34.68 20 15.13 434 131 3.65 / 303.82 5 33
6 13 12.08 20 15.13 401 121 3.77 / 303.94 5 31
7 8 0.00 291 15.06 364 1595 5.36 / 305.53 5 151
Average= 5.36
(KJ/cycle)

Cycle 55 GMT 1/ 5/2024 2: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 28 15.08 495 209 0.21 / 295.07 5 6
2 7 2006.80 40 14.76 3569 2107 2.32 / 297.18 6 23
3 13 1277.96 20 14.83 2476 734 3.05 / 297.92 4 32
4 13 570.84 20 14.98 1353 405 3.46 / 298.32 4 36
5 13 37.60 20 15.13 452 137 3.59 / 298.46 5 32
6 8 -0.04 308 15.07 369 1713 5.31 / 300.17 5 138
Average= 5.36
(KJ/cycle)

Cycle 54 GMT 20/ 4/2024 19:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 28 15.09 507 214 0.21 / 289.97 5 6
2 7 2007.72 40 14.75 3563 2102 2.32 / 292.07 6 24
3 13 1093.08 20 14.87 2187 650 2.97 / 292.72 4 34
4 13 526.52 20 15.00 1273 382 3.35 / 293.10 4 36
5 13 35.28 20 15.14 438 133 3.48 / 293.23 5 32
6 8 -0.04 302 15.08 358 1630 5.11 / 294.87 5 145
Average= 5.36
(KJ/cycle)

Cycle 53 GMT 10/ 4/2024 12:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 28 15.09 501 212 0.21 / 284.74 5 6
2 7 2006.40 40 14.77 3566 2107 2.32 / 286.85 6 23
3 13 1274.00 20 14.85 2456 729 3.05 / 287.58 4 30
4 13 582.08 20 14.99 1370 411 3.46 / 287.99 4 36
5 13 33.68 20 15.15 436 132 3.59 / 288.12 5 31
6 8 0.08 306 15.09 354 1635 5.23 / 289.75 5 146
Average= 5.37
(KJ/cycle)

Cycle 52 GMT 31/ 3/2024 5:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 28 15.08 521 220 0.22 / 279.54 5 6
2 7 2002.72 41 14.76 3555 2151 2.37 / 281.70 6 23
3 13 1163.32 20 14.88 2280 679 3.05 / 282.37 4 32
4 13 487.40 20 15.02 1215 365 3.41 / 282.74 4 35
5 13 29.40 20 15.15 426 129 3.54 / 282.87 5 31
6 8 0.12 308 15.09 357 1659 5.20 / 284.53 5 143
Average= 5.37
(KJ/cycle)

Cycle 51 GMT 20/ 3/2024 23:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 28 15.09 506 214 0.21 / 274.30 5 6
2 7 2004.28 40 14.77 3558 2102 2.32 / 276.41 6 24
3 13 1147.48 20 14.88 2270 676 2.99 / 277.08 4 32
4 13 575.72 20 15.00 1360 408 3.40 / 277.49 4 38
5 13 30.40 20 15.16 431 131 3.53 / 277.62 5 31
6 8 0.00 312 15.09 362 1704 5.23 / 279.32 5 145
Average= 5.37
(KJ/cycle)

Cycle 50 GMT 10/ 3/2024 16:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 28 15.10 491 208 0.21 / 269.10 5 6
2 7 2003.64 40 14.77 3566 2107 2.31 / 271.21 6 24
3 13 1048.24 20 14.91 2115 631 2.95 / 271.84 4 32
4 13 591.00 20 15.00 1388 416 3.36 / 272.26 4 38
5 13 36.40 20 15.16 436 132 3.49 / 272.39 5 32
6 8 -0.04 314 15.10 359 1702 5.20 / 274.09 5 154
Average= 5.37
(KJ/cycle)

Cycle 49 GMT 29/ 2/2024 10:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 28 15.10 500 211 0.21 / 263.85 5 6
2 7 2009.04 40 14.77 3578 2114 2.33 / 265.96 6 24
3 13 1264.80 20 14.86 2461 731 3.06 / 266.69 4 33
4 13 562.28 20 15.01 1341 403 3.46 / 267.10 4 37
5 13 27.32 20 15.17 418 127 3.59 / 267.22 5 30
6 8 0.04 310 15.10 357 1671 5.26 / 268.89 5 146
Average= 5.38
(KJ/cycle)

Cycle 48 GMT 19/ 2/2024 3:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 28 15.12 506 214 0.21 / 258.57 5 6
2 7 2004.68 40 14.77 3569 2109 2.32 / 260.68 6 23
3 13 1161.52 20 14.89 2298 684 3.01 / 261.36 4 33
4 13 673.88 20 14.98 1525 457 3.46 / 261.82 4 38
5 13 36.88 20 15.17 441 134 3.60 / 261.96 5 32
6 13 12.40 20 15.16 395 120 3.72 / 262.08 5 31
7 8 0.00 285 15.10 363 1562 5.28 / 263.64 5 131
Average= 5.38
(KJ/cycle)

Cycle 47 GMT 8/ 2/2024 20:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 28 15.12 507 215 0.21 / 253.35 5 5
2 7 2003.72 40 14.78 3566 2108 2.32 / 255.46 5 24
3 13 1245.84 20 14.88 2425 722 3.04 / 256.18 4 33
4 13 554.88 20 15.03 1334 401 3.45 / 256.58 4 37
5 13 46.32 20 15.17 457 139 3.58 / 256.72 5 31
6 13 17.68 20 15.17 406 123 3.71 / 256.85 5 31
7 8 0.04 278 15.11 360 1512 5.22 / 258.36 5 142
Average= 5.38
(KJ/cycle)

Cycle 46 GMT 29/ 1/2024 13:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 28 15.11 510 216 0.22 / 248.06 5 6
2 7 2007.04 41 14.78 3580 2169 2.39 / 250.23 6 24
3 13 1164.92 20 14.90 2298 685 3.07 / 250.91 4 33
4 13 590.36 20 15.02 1391 418 3.49 / 251.33 4 37
5 13 49.68 20 15.17 467 142 3.63 / 251.47 5 33
6 13 34.48 20 15.17 439 133 3.76 / 251.61 5 33
7 8 0.08 280 15.11 362 1532 5.29 / 253.14 5 143
Average= 5.39
(KJ/cycle)

Cycle 45 GMT 19/ 1/2024 7:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 28 15.13 506 214 0.21 / 242.69 5 5
2 7 2010.08 40 14.78 3588 2121 2.34 / 244.81 5 24
3 13 1265.40 20 14.88 2462 733 3.07 / 245.55 4 33
4 13 668.84 20 15.00 1518 455 3.52 / 246.00 4 38
5 13 65.44 20 15.17 495 150 3.67 / 246.15 5 33
6 13 37.36 20 15.17 446 135 3.81 / 246.29 5 34
7 8 0.12 282 15.12 365 1556 5.37 / 247.84 5 131
Average= 5.39
(KJ/cycle)

Cycle 44 GMT 9/ 1/2024 0:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 28 15.14 510 216 0.22 / 237.43 5 5
2 7 2003.36 40 14.79 3569 2111 2.33 / 239.54 5 24
3 13 1261.56 20 14.89 2449 729 3.06 / 240.27 4 32
4 13 564.36 20 15.04 1340 403 3.46 / 240.68 4 37
5 13 54.28 20 15.18 478 145 3.61 / 240.82 5 32
6 13 34.36 20 15.18 442 134 3.74 / 240.96 5 32
7 8 0.00 278 15.13 362 1523 5.26 / 242.48 5 141
Average= 5.39
(KJ/cycle)

Cycle 43 GMT 29/12/2023 18: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 28 15.14 512 217 0.22 / 232.16 5 6
2 7 2005.28 40 14.79 3572 2113 2.33 / 234.27 6 24
3 13 1172.48 20 14.91 2324 693 3.02 / 234.97 4 32
4 13 704.40 20 15.00 1573 472 3.50 / 235.44 4 37
5 13 53.52 20 15.18 474 144 3.64 / 235.58 5 33
6 13 39.60 20 15.18 449 136 3.78 / 235.72 5 33
7 8 0.04 276 15.13 359 1499 5.27 / 237.22 5 155
Average= 5.39
(KJ/cycle)

Cycle 42 GMT 19/12/2023 11:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 28 15.14 506 215 0.21 / 226.91 5 5
2 7 2006.48 40 14.79 3569 2111 2.33 / 229.02 5 23
3 13 1263.32 20 14.90 2455 732 3.06 / 229.75 4 31
4 13 553.84 20 15.05 1334 402 3.46 / 230.16 4 36
5 13 45.28 20 15.19 460 140 3.60 / 230.30 5 32
6 13 18.08 20 15.19 411 125 3.72 / 230.42 5 31
7 8 0.00 276 15.14 364 1521 5.24 / 231.94 5 132
Average= 5.39
(KJ/cycle)

Cycle 41 GMT 9/12/2023 5: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 28 15.14 510 216 0.22 / 221.67 5 5
2 7 2002.60 40 14.79 3567 2110 2.33 / 223.78 5 22
3 13 1243.12 20 14.91 2423 723 3.05 / 224.51 4 31
4 13 547.76 20 15.06 1320 398 3.45 / 224.90 4 36
5 13 42.88 20 15.20 456 139 3.59 / 225.04 5 32
6 13 20.12 20 15.20 416 126 3.71 / 225.17 5 31
7 8 -0.04 278 15.14 363 1528 5.24 / 226.70 5 157
Average= 5.40
(KJ/cycle)

Cycle 40 GMT 28/11/2023 22:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 28 15.15 494 210 0.21 / 216.32 5 5
2 7 2003.16 41 14.79 3569 2164 2.37 / 218.49 5 24
3 13 1267.72 20 14.91 2454 732 3.11 / 219.22 4 33
4 13 556.28 20 15.06 1336 402 3.51 / 219.62 4 37
5 13 44.64 20 15.20 463 141 3.65 / 219.76 5 33
6 13 27.52 20 15.20 433 132 3.78 / 219.89 5 33
7 8 0.00 280 15.14 369 1564 5.34 / 221.46 5 140
Average= 5.40
(KJ/cycle)

Cycle 39 GMT 18/11/2023 16: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 28 15.15 505 214 0.21 / 211.13 5 5
2 7 2002.48 40 14.80 3568 2112 2.33 / 213.24 5 23
3 13 1142.76 20 14.94 2259 675 3.00 / 213.92 4 32
4 13 469.16 20 15.09 1177 355 3.36 / 214.27 4 36
5 13 43.28 20 15.20 451 137 3.49 / 214.41 5 32
6 13 15.80 20 15.21 400 122 3.62 / 214.53 5 31
7 8 -0.16 285 15.14 367 1584 5.20 / 216.11 5 139
Average= 5.40
(KJ/cycle)

Cycle 38 GMT 8/11/2023 9:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 28 15.15 508 215 0.22 / 205.86 5 6
2 7 2009.40 40 14.80 3569 2113 2.33 / 207.97 6 24
3 13 1164.56 20 14.94 2305 689 3.02 / 208.66 4 33
4 13 593.76 20 15.06 1389 418 3.44 / 209.08 4 38
5 13 44.16 20 15.21 454 138 3.57 / 209.22 5 33
6 13 15.48 20 15.21 408 124 3.70 / 209.34 5 32
7 8 0.08 285 15.15 364 1572 5.27 / 210.91 5 133
Average= 5.41
(KJ/cycle)

Cycle 37 GMT 29/10/2023 2:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 28 15.16 505 214 0.21 / 200.61 5 5
2 7 2002.88 40 14.80 3564 2110 2.32 / 202.72 5 24
3 13 1243.44 20 14.92 2427 724 3.05 / 203.45 4 32
4 13 436.64 20 15.11 1135 343 3.39 / 203.79 4 36
5 13 40.92 20 15.21 456 139 3.53 / 203.93 5 32
6 13 15.08 20 15.21 410 125 3.65 / 204.05 5 31
7 8 -0.04 285 15.15 369 1593 5.25 / 205.64 5 137
Average= 5.41
(KJ/cycle)

Cycle 36 GMT 18/10/2023 19:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 28 15.16 505 214 0.21 / 195.35 5 6
2 7 2009.20 40 14.81 3576 2118 2.33 / 197.47 6 23
3 13 1267.84 20 14.93 2448 731 3.06 / 198.20 4 31
4 13 559.36 20 15.08 1334 402 3.47 / 198.60 4 36
5 13 43.32 20 15.22 448 136 3.60 / 198.74 5 32
6 13 18.88 20 15.21 409 124 3.73 / 198.86 5 31
7 8 0.08 282 15.16 359 1535 5.26 / 200.40 5 145
Average= 5.42
(KJ/cycle)

Cycle 35 GMT 8/10/2023 13:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 28 15.16 517 219 0.22 / 190.08 5 5
2 7 2001.72 40 14.81 3559 2108 2.33 / 192.19 5 23
3 13 1151.28 20 14.96 2274 680 3.01 / 192.87 4 33
4 13 579.12 20 15.08 1363 411 3.42 / 193.28 4 37
5 13 47.60 20 15.22 456 139 3.56 / 193.42 5 32
6 13 27.08 20 15.21 430 131 3.69 / 193.55 5 32
7 8 0.08 287 15.16 364 1584 5.27 / 195.14 5 138
Average= 5.42
(KJ/cycle)

Cycle 34 GMT 28/ 9/2023 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 28 15.17 507 215 0.22 / 184.90 5 5
2 7 2003.00 40 14.81 3569 2114 2.33 / 187.02 5 23
3 13 1145.96 20 14.96 2266 678 3.01 / 187.70 4 32
4 13 559.48 20 15.08 1329 401 3.41 / 188.10 4 38
5 13 47.84 20 15.22 455 139 3.55 / 188.24 5 32
6 13 30.80 20 15.22 429 131 3.68 / 188.37 5 32
7 8 0.00 285 15.17 346 1496 5.17 / 189.86 5 138
Average= 5.42
(KJ/cycle)

Cycle 33 GMT 17/ 9/2023 23:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 28 15.17 511 217 0.22 / 179.73 5 5
2 7 2008.68 40 14.82 3558 2109 2.33 / 181.84 5 22
3 13 1240.36 20 14.94 2401 717 3.04 / 182.55 4 32
4 13 521.40 20 15.10 1254 379 3.42 / 182.93 4 37
5 13 63.36 20 15.22 471 143 3.57 / 183.08 5 33
6 13 40.84 20 15.22 439 134 3.70 / 183.21 5 33
7 8 0.04 285 15.17 342 1479 5.18 / 184.69 5 147
Average= 5.43
(KJ/cycle)

Cycle 32 GMT 7/ 9/2023 17:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 28 15.18 500 213 0.21 / 174.58 5 6
2 7 2006.48 41 14.82 3545 2154 2.37 / 176.74 6 24
3 13 1175.44 20 14.96 2285 684 3.05 / 177.42 4 33
4 13 576.76 20 15.09 1328 401 3.45 / 177.82 4 37
5 13 55.32 20 15.23 445 136 3.59 / 177.96 5 32
6 13 32.88 20 15.23 405 123 3.71 / 178.08 5 32
7 8 -0.04 285 15.18 331 1432 5.14 / 179.51 5 151
Average= 5.44
(KJ/cycle)

Cycle 31 GMT 28/ 8/2023 10:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 28 15.00 503 211 0.21 / 169.40 5 5
2 7 2002.12 41 14.84 3533 2150 2.36 / 171.55 5 23
3 13 1255.32 20 14.96 2405 720 3.08 / 172.27 4 30
4 13 539.16 20 15.11 1262 381 3.46 / 172.65 4 36
5 13 64.84 20 15.24 463 141 3.60 / 172.79 5 33
6 13 39.32 20 15.24 419 128 3.73 / 172.92 5 33
7 8 0.16 289 15.19 330 1449 5.18 / 174.37 5 156
Average= 5.45
(KJ/cycle)

Cycle 30 GMT 18/ 8/2023 4: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 28 15.18 512 218 0.22 / 150.78 5 6
2 7 1195.36 40 15.11 2337 1412 1.63 / 152.20 6 29
3 13 1194.48 20 15.06 2348 707 2.34 / 152.90 4 32
4 13 1194.56 20 15.01 2353 706 3.04 / 153.61 4 35
5 13 1194.56 20 14.96 2341 700 3.74 / 154.31 4 33
6 13 1194.56 20 14.91 2346 700 4.44 / 155.01 4 36
7 13 1194.56 20 14.87 2344 697 5.14 / 155.71 4 36
8 13 1194.56 20 14.84 2349 697 5.84 / 156.40 4 37
9 13 1194.52 20 14.81 2351 696 6.53 / 157.10 4 40
10 13 1194.52 20 14.78 2346 693 7.23 / 157.79 4 42
11 13 1194.48 20 14.76 2338 690 7.92 / 158.48 4 42
12 13 1194.44 20 14.74 2349 692 8.61 / 159.18 4 43
13 13 1194.36 20 14.72 2339 689 9.30 / 159.87 4 46
14 13 1194.32 20 14.71 2335 687 9.99 / 160.55 4 49
15 13 1194.24 20 14.70 2327 684 10.67 / 161.24 4 52
16 13 1194.16 20 14.68 2331 684 11.35 / 161.92 5 56
17 13 1194.12 20 14.68 2331 684 12.04 / 162.60 5 58
18 13 1194.04 20 14.65 2336 684 12.72 / 163.29 6 59
19 13 1193.96 20 14.65 2321 680 13.40 / 163.97 7 65
20 13 1193.88 20 14.63 2324 680 14.08 / 164.65 8 70
21 13 1193.84 20 14.61 2322 678 14.76 / 165.33 11 83
22 13 1193.76 20 14.60 2317 677 15.44 / 166.00 23 117
23 13 1193.68 20 14.59 2303 672 16.11 / 166.68 53 -99
24 13 1193.64 20 14.71 1392 410 16.52 / 167.09 -99 -99
25 13 1193.56 20 14.78 1048 310 16.83 / 167.40 -99 -99
26 13 1193.52 20 14.85 568 169 17.00 / 167.56 -99 -99
27 13 1193.48 20 14.89 456 136 17.13 / 167.70 -99 -99
28 13 1193.48 20 14.89 454 135 17.27 / 167.84 -99 -99
29 13 1193.44 20 14.92 353 105 17.37 / 167.94 -99 -99
30 13 1193.44 20 14.91 408 122 17.50 / 168.06 -99 -99
31 13 1193.44 20 14.90 496 148 17.64 / 168.21 -99 -99
32 13 1193.40 20 14.91 499 149 17.79 / 168.36 -99 -99
33 14 -0.56 200 14.94 278 831 18.62 / 169.19 -99 -99
Average= 5.46
(KJ/cycle)

Cycle 29 GMT 7/ 8/2023 13:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 28 15.19 511 217 0.22 / 145.54 5 6
2 7 2004.56 40 14.83 3576 2121 2.34 / 147.66 6 24
3 13 1157.40 20 14.97 2297 688 3.03 / 148.35 4 34
4 13 583.68 20 15.09 1391 420 3.45 / 148.77 4 38
5 13 49.56 20 15.24 467 142 3.59 / 148.91 5 33
6 13 30.08 20 15.24 438 134 3.72 / 149.05 5 32
7 8 0.04 272 15.18 368 1519 5.24 / 150.57 5 129
Average= 5.02
(KJ/cycle)

Cycle 28 GMT 28/ 7/2023 7: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 28 15.19 517 220 0.22 / 140.31 5 6
2 7 2005.12 40 14.83 3576 2121 2.34 / 142.43 14 24
3 13 1149.56 20 14.98 2282 684 3.02 / 143.11 4 33
4 13 558.76 20 15.11 1338 404 3.43 / 143.52 4 37
5 13 41.68 20 15.25 453 138 3.57 / 143.66 5 31
6 13 17.56 20 15.25 410 125 3.69 / 143.78 5 31
7 8 -0.08 274 15.18 371 1543 5.24 / 145.32 5 137
Average= 5.01
(KJ/cycle)

Cycle 27 GMT 18/ 7/2023 0:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 27 15.19 517 212 0.21 / 135.04 5 5
2 7 2003.52 40 14.84 3576 2123 2.33 / 137.16 5 24
3 13 1164.40 20 14.99 2306 691 3.03 / 137.85 4 31
4 13 690.76 20 15.07 1558 470 3.50 / 138.32 4 37
5 13 43.76 20 15.25 452 138 3.63 / 138.46 5 33
6 13 24.60 20 15.25 421 128 3.76 / 138.59 5 33
7 8 0.04 272 15.19 364 1504 5.27 / 140.09 5 132
Average= 5.00
(KJ/cycle)

Cycle 26 GMT 7/ 7/2023 17:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 27 15.19 519 213 0.21 / 129.84 5 6
2 7 2001.76 40 14.85 3574 2123 2.34 / 131.96 6 23
3 13 1118.40 20 15.00 2235 670 3.01 / 132.63 4 34
4 13 536.44 20 15.12 1310 396 3.40 / 133.03 4 38
5 13 40.00 20 15.25 450 137 3.54 / 133.16 5 32
6 13 13.76 20 15.25 406 124 3.66 / 133.29 5 32
7 8 -0.04 274 15.19 369 1536 5.20 / 134.82 5 141
Average= 4.99
(KJ/cycle)

Cycle 25 GMT 27/ 6/2023 10:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 27 15.20 514 211 0.21 / 124.56 5 6
2 7 2006.00 40 14.85 3574 2123 2.33 / 126.68 6 24
3 13 1157.24 20 15.00 2294 688 3.02 / 127.37 4 32
4 13 568.92 20 15.11 1360 411 3.43 / 127.78 4 37
5 13 44.92 20 15.25 464 142 3.57 / 127.92 5 33
6 13 25.80 20 15.25 434 132 3.71 / 128.05 5 33
7 8 0.04 278 15.19 372 1571 5.28 / 129.62 5 135
Average= 4.99
(KJ/cycle)

Cycle 24 GMT 17/ 6/2023 4:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 27 15.19 537 220 0.22 / 119.26 5 6
2 7 2001.16 40 14.85 3572 2122 2.34 / 121.38 6 25
3 13 1349.08 20 14.95 2600 777 3.12 / 122.16 4 32
4 13 498.80 20 15.14 1242 376 3.50 / 122.53 4 37
5 13 52.44 20 15.26 470 143 3.64 / 122.67 5 33
6 13 15.92 20 15.26 408 125 3.76 / 122.80 5 32
7 8 0.04 278 15.20 366 1547 5.31 / 124.35 5 143
Average= 4.97
(KJ/cycle)

Cycle 23 GMT 6/ 6/2023 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 27 15.20 509 209 0.21 / 113.83 5 6
2 7 2005.40 40 14.86 3572 2123 2.33 / 115.95 6 23
3 13 1360.00 20 14.96 2598 777 3.11 / 116.73 4 32
4 13 629.12 20 15.10 1454 439 3.55 / 117.17 4 39
5 13 45.08 20 15.26 466 142 3.69 / 117.31 5 34
6 13 12.12 20 15.26 405 124 3.81 / 117.43 5 31
7 8 0.04 280 15.20 377 1605 5.42 / 119.04 5 144
Average= 4.96
(KJ/cycle)

Cycle 22 GMT 27/ 5/2023 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 27 15.20 535 220 0.22 / 108.54 5 6
2 7 2003.92 41 14.86 3580 2181 2.40 / 110.72 6 25
3 13 1157.52 20 15.00 2294 688 3.09 / 111.41 4 34
4 13 556.60 20 15.13 1344 407 3.50 / 111.81 4 37
5 13 33.40 20 15.26 447 136 3.63 / 111.95 5 33
6 8 0.04 297 15.21 369 1667 5.30 / 113.62 5 135
Average= 4.94
(KJ/cycle)

Cycle 21 GMT 17/ 5/2023 8:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 27 15.21 515 211 0.21 / 103.22 5 6
2 7 2005.48 40 14.86 3579 2127 2.34 / 105.35 6 23
3 13 1171.28 20 15.01 2313 694 3.03 / 106.05 4 33
4 13 567.52 20 15.12 1362 412 3.45 / 106.46 4 37
5 13 34.12 20 15.26 448 137 3.58 / 106.59 5 33
6 8 -0.04 300 15.20 378 1724 5.31 / 108.32 5 141
Average= 4.92
(KJ/cycle)

Cycle 20 GMT 7/ 5/2023 1:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 27 15.21 549 225 0.23 / 97.99 5 6
2 7 2005.68 40 14.87 3582 2131 2.36 / 100.13 6 24
3 13 1163.44 20 15.01 2305 692 3.05 / 100.82 4 33
4 13 484.12 20 15.15 1228 372 3.42 / 101.19 4 37
5 13 28.92 20 15.27 438 134 3.55 / 101.32 5 33
6 8 0.00 297 15.21 374 1689 5.24 / 103.01 5 132
Average= 4.91
(KJ/cycle)

Cycle 19 GMT 26/ 4/2023 18:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 27 15.21 516 212 0.21 / 92.67 5 6
2 7 2003.72 40 14.87 3576 2127 2.34 / 94.80 6 23
3 13 1168.00 20 15.01 2316 695 3.03 / 95.49 4 33
4 13 594.96 20 15.12 1410 426 3.46 / 95.92 4 37
5 13 33.00 20 15.27 452 138 3.60 / 96.06 5 33
6 8 0.12 297 15.21 379 1712 5.31 / 97.77 5 145
Average= 4.89
(KJ/cycle)

Cycle 18 GMT 16/ 4/2023 12: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 27 15.22 517 212 0.21 / 87.32 5 6
2 7 2003.04 41 14.87 3582 2184 2.40 / 89.50 6 25
3 13 1256.64 20 15.00 2451 735 3.13 / 90.24 4 34
4 13 546.32 20 15.14 1333 404 3.54 / 90.64 4 38
5 13 28.20 20 15.28 434 133 3.67 / 90.77 5 33
6 8 0.04 295 15.22 375 1684 5.35 / 92.46 5 135
Average= 4.87
(KJ/cycle)

Cycle 17 GMT 6/ 4/2023 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 27 15.22 533 219 0.22 / 81.98 5 6
2 7 2002.40 40 14.88 3573 2127 2.35 / 84.11 6 24
3 13 1249.68 20 15.00 2446 734 3.08 / 84.84 4 34
4 13 646.44 20 15.12 1493 451 3.53 / 85.29 4 38
5 13 35.40 20 15.28 448 137 3.67 / 85.43 5 33
6 8 -0.04 295 15.22 374 1679 5.35 / 87.11 5 132
Average= 4.84
(KJ/cycle)

Cycle 16 GMT 26/ 3/2023 22:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 27 15.22 523 215 0.21 / 76.70 5 6
2 7 2004.20 40 14.89 3563 2122 2.34 / 78.83 6 24
3 13 1224.04 20 15.02 2392 719 3.06 / 79.54 4 33
4 13 528.40 20 15.16 1288 391 3.45 / 79.93 4 37
5 13 63.76 20 15.28 496 152 3.60 / 80.09 5 34
6 8 0.08 297 15.23 370 1674 5.27 / 81.76 5 136
Average= 4.81
(KJ/cycle)

Cycle 15 GMT 16/ 3/2023 16: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 27 15.22 533 219 0.22 / 71.46 5 6
2 7 2007.56 40 14.88 3578 2130 2.35 / 73.59 6 24
3 13 1096.64 20 15.04 2206 664 3.01 / 74.25 4 33
4 13 637.04 20 15.12 1475 446 3.46 / 74.70 4 39
5 13 34.00 20 15.29 439 134 3.59 / 74.83 5 32
6 8 0.08 295 15.23 369 1658 5.25 / 76.49 5 143
Average= 4.78
(KJ/cycle)

Cycle 14 GMT 6/ 3/2023 9: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 27 15.23 522 215 0.21 / 66.24 5 6
2 7 2007.84 40 14.89 3584 2135 2.35 / 68.38 6 24
3 13 1145.08 20 15.03 2282 686 3.04 / 69.06 4 36
4 13 459.92 20 15.18 1184 359 3.39 / 69.42 4 37
5 13 40.12 20 15.29 452 138 3.53 / 69.56 5 33
6 8 0.08 295 15.23 373 1676 5.21 / 71.24 5 139
Average= 4.75
(KJ/cycle)

Cycle 13 GMT 24/ 2/2023 2:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 27 15.23 522 215 0.21 / 60.99 5 6
2 7 2003.48 40 14.89 3577 2130 2.35 / 63.12 6 24
3 13 1241.76 20 15.02 2428 729 3.07 / 63.85 4 33
4 13 505.76 20 15.17 1266 384 3.46 / 64.24 4 37
5 13 44.72 20 15.29 463 142 3.60 / 64.38 5 33
6 8 0.04 293 15.24 370 1652 5.25 / 66.03 5 135
Average= 4.72
(KJ/cycle)

Cycle 12 GMT 13/ 2/2023 19:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 27 15.23 515 212 0.21 / 55.66 5 6
2 7 2006.20 40 14.90 3578 2132 2.34 / 57.79 6 24
3 13 1265.60 20 15.01 2467 741 3.08 / 58.53 4 33
4 13 652.28 20 15.13 1497 453 3.54 / 58.99 4 38
5 13 36.32 20 15.30 445 136 3.67 / 59.12 5 32
6 8 0.04 295 15.24 368 1654 5.33 / 60.78 5 142
Average= 4.68
(KJ/cycle)

Cycle 11 GMT 3/ 2/2023 12:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 27 15.23 528 217 0.22 / 50.40 5 6
2 7 2004.68 40 14.90 3571 2128 2.35 / 52.52 6 26
3 13 1139.08 20 15.04 2283 687 3.03 / 53.21 4 34
4 13 546.88 20 15.16 1335 405 3.44 / 53.62 4 37
5 13 34.84 20 15.30 453 139 3.58 / 53.75 4 32
6 8 0.12 295 15.24 377 1695 5.27 / 55.45 5 134
Average= 4.62
(KJ/cycle)

Cycle 10 GMT 24/ 1/2023 6: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 27 15.24 513 211 0.21 / 45.06 5 6
2 10 1000.52 3 15.21 2034 93 0.30 / 45.15 4 19
3 3 912.04 -1 15.56 0 0 0.09 / 45.15 4 19
4 7 2002.48 40 14.90 3582 2135 2.44 / 47.28 19 24
5 13 1069.00 20 15.06 2168 653 3.09 / 47.94 4 34
6 13 614.56 20 15.15 1441 437 3.53 / 48.37 4 38
7 13 25.64 20 15.30 429 131 3.66 / 48.50 5 33
8 8 0.00 293 15.24 375 1674 5.33 / 50.18 5 132
Average= 4.56
(KJ/cycle)

Cycle 9 GMT 13/ 1/2023 23: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 27 15.24 523 215 0.22 / 39.90 5 6
2 7 2001.44 41 14.91 3567 2181 2.40 / 42.08 6 25
3 13 1036.28 20 15.07 2117 638 3.03 / 42.72 4 35
4 13 478.08 20 15.19 1214 369 3.40 / 43.08 4 37
5 13 28.36 20 15.30 429 131 3.53 / 43.22 5 31
6 8 0.12 291 15.25 367 1629 5.16 / 44.84 5 134
Average= 4.48
(KJ/cycle)

Cycle 8 GMT 3/ 1/2023 16:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 27 15.24 533 219 0.22 / 34.70 5 6
2 7 2002.56 40 14.91 3574 2132 2.35 / 36.83 16 24
3 13 1116.92 20 15.06 2237 674 3.02 / 37.51 4 34
4 13 449.12 20 15.20 1165 354 3.38 / 37.86 4 36
5 13 40.28 20 15.30 457 140 3.52 / 38.00 5 32
6 8 0.04 291 15.25 379 1682 5.20 / 39.68 5 137
Average= 4.41
(KJ/cycle)

Cycle 7 GMT 24/12/2022 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 27 15.24 521 214 0.21 / 29.45 5 6
2 7 2005.60 40 14.92 3587 2141 2.36 / 31.59 6 25
3 13 1240.00 20 15.04 2428 730 3.09 / 32.32 4 33
4 13 433.48 20 15.21 1133 345 3.43 / 32.67 4 36
5 13 35.88 20 15.31 450 138 3.57 / 32.80 5 33
6 13 14.08 20 15.30 405 124 3.69 / 32.93 5 33
7 8 0.08 274 15.24 372 1553 5.25 / 34.48 5 148
Average= 4.31
(KJ/cycle)

Cycle 6 GMT 14/12/2022 2:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 25 15.24 529 202 0.20 / 24.10 5 6
2 10 1044.48 3 15.22 2093 96 0.30 / 24.20 5 17
3 7 2004.96 41 14.92 3578 2189 2.49 / 26.39 17 23
4 13 1118.88 20 15.06 2239 674 3.16 / 27.06 4 32
5 13 448.24 20 15.20 1161 353 3.51 / 27.42 4 36
6 13 45.48 20 15.31 458 140 3.65 / 27.56 5 32
7 13 28.40 20 15.30 435 133 3.79 / 27.69 5 34
8 8 0.04 272 15.24 373 1546 5.33 / 29.24 5 136
Average= 4.18
(KJ/cycle)

Cycle 5 GMT 3/12/2022 19:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 31 15.24 515 243 0.24 / 18.80 5 5
2 3 803.24 -3 15.58 0 0 0.00 / 18.80 5 5
3 7 2001.68 40 14.92 3568 2129 2.37 / 20.93 5 25
4 13 1227.24 20 15.05 2398 722 3.09 / 21.65 4 30
5 13 599.80 20 15.16 1416 429 3.52 / 22.08 4 38
6 13 40.44 20 15.31 464 142 3.67 / 22.22 5 31
7 13 22.00 20 15.30 426 130 3.80 / 22.35 5 24
8 8 0.04 270 15.25 376 1548 5.34 / 23.90 5 146
Average= 3.98
(KJ/cycle)

Cycle 4 GMT 23/11/2022 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 25 15.24 516 197 0.20 / 14.23 5 6
2 7 1518.04 40 15.08 2830 1707 1.90 / 15.93 25 25
3 13 971.36 20 15.14 1994 604 2.51 / 16.54 4 34
4 13 292.80 20 15.27 889 272 2.78 / 16.81 4 32
5 13 26.88 20 15.33 433 133 2.91 / 16.94 5 24
6 13 12.08 20 15.32 405 124 3.04 / 17.07 5 35
7 8 0.04 263 15.26 372 1493 4.53 / 18.56 5 131
Average= 3.71
(KJ/cycle)

Cycle 3 GMT 22/11/2022 2:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 24 15.25 501 183 0.18 / 9.62 5 5
2 10 1016.80 3 15.23 2029 93 0.28 / 9.71 5 16
3 3 964.68 -1 15.57 0 0 0.09 / 9.71 5 16
4 7 1516.84 40 15.08 2816 1699 1.97 / 11.41 16 25
5 13 973.56 20 15.14 1991 603 2.58 / 12.01 4 33
6 13 275.12 20 15.28 857 262 2.84 / 12.28 4 34
7 13 28.48 20 15.32 435 133 2.97 / 12.41 5 33
8 13 10.92 20 15.32 404 124 3.10 / 12.53 5 33
9 8 -0.08 265 15.26 370 1496 4.59 / 14.03 5 142
Average= 3.51
(KJ/cycle)

Cycle 2 GMT 20/11/2022 16:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 31 15.28 504 239 0.24 / 5.16 5 7
2 3 788.40 -3 15.59 0 0 0.00 / 5.16 5 7
3 7 1522.16 40 15.09 2814 1699 1.94 / 6.86 7 23
4 13 1074.36 20 15.13 2134 646 2.58 / 7.50 4 31
5 13 261.28 20 15.29 819 250 2.83 / 7.75 4 33
6 13 31.08 20 15.34 424 130 2.96 / 7.88 5 31
7 13 13.24 20 15.33 387 119 3.08 / 8.00 5 28
8 8 -0.04 265 15.27 355 1437 4.52 / 9.44 5 137
Average= 3.15
(KJ/cycle)

Cycle 1 GMT 19/11/2022 6:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 31 15.44 470 225 0.22 / 2.16 5 5
2 3 779.64 -3 15.60 0 0 0.00 / 2.16 5 5
3 7 855.36 40 15.25 1761 1074 1.30 / 3.24 5 29
4 13 29.56 20 15.40 407 125 1.42 / 3.36 4 29
5 13 11.56 20 15.40 377 116 1.54 / 3.48 5 30
6 8 0.00 270 15.33 348 1440 2.98 / 4.92 5 143
Average= 2.46
(KJ/cycle)

Cycle 0 GMT 18/11/2022 20:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 93.36 30 15.61 465 218 0.22 / 0.22 5 7
2 7 105.24 40 15.58 473 295 0.51 / 0.51 7 9
3 13 26.08 20 15.58 342 107 0.62 / 0.62 5 12
4 8 0.16 285 15.52 298 1318 1.94 / 1.94 5 146
Average= 1.94
(KJ/cycle)