SIO Argo Site:
Pump Diagnostics Page   



Serial= 7718 WMO= 4903479

Return

←PreviousNext→

Cycle 78 GMT 19/12/2024 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 31 15.00 399 186 0.19 / 399.58 6 6
2 7 2004.64 41 14.68 2935 1767 1.95 / 401.35 6 22
3 13 1792.68 20 14.67 2690 789 2.74 / 402.13 5 28
4 13 1386.44 20 14.67 2195 644 3.39 / 402.78 5 31
5 13 827.56 20 14.76 1488 439 3.82 / 403.22 5 35
6 13 140.32 20 14.98 537 161 3.99 / 403.38 5 38
7 13 39.36 20 15.01 378 113 4.10 / 403.49 5 28
8 8 -0.12 253 14.97 304 1151 5.25 / 404.64 6 135
Average= 5.12
(KJ/cycle)

Cycle 77 GMT 9/12/2024 5:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 31 14.99 399 185 0.19 / 394.42 6 6
2 7 2003.80 41 14.68 2946 1773 1.96 / 396.20 6 22
3 13 1906.44 20 14.65 2839 832 2.79 / 397.03 5 24
4 13 1261.64 20 14.70 2026 596 3.39 / 397.62 5 32
5 13 645.88 20 14.82 1242 368 3.75 / 397.99 5 36
6 13 104.24 20 15.00 480 144 3.90 / 398.14 5 35
7 13 56.68 20 15.01 407 122 4.02 / 398.26 5 41
8 8 -0.12 253 14.97 300 1136 5.16 / 399.39 5 137
Average= 5.12
(KJ/cycle)

Cycle 76 GMT 28/11/2024 21:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 31 15.01 398 185 0.19 / 389.08 6 7
2 7 2007.40 40 14.68 2956 1736 1.92 / 390.81 7 23
3 13 1810.84 20 14.66 2725 799 2.72 / 391.61 5 28
4 13 1385.36 20 14.67 2196 644 3.36 / 392.26 5 30
5 13 735.76 20 14.79 1367 404 3.77 / 392.66 5 36
6 13 407.68 20 14.88 918 273 4.04 / 392.94 5 37
7 13 75.04 20 14.99 443 133 4.17 / 393.07 5 36
8 8 -0.08 257 14.96 304 1169 5.34 / 394.24 5 133
Average= 5.12
(KJ/cycle)

Cycle 75 GMT 18/11/2024 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 31 14.99 406 189 0.19 / 383.86 6 7
2 7 2006.00 41 14.68 2952 1777 1.97 / 385.64 7 21
3 13 1907.80 20 14.67 2831 831 2.80 / 386.47 5 26
4 13 1363.80 20 14.68 2172 638 3.43 / 387.11 5 32
5 13 684.52 20 14.81 1306 387 3.82 / 387.50 5 36
6 13 90.48 20 15.01 463 139 3.96 / 387.63 5 36
7 13 53.80 20 15.02 403 121 4.08 / 387.76 5 34
8 8 0.04 255 14.98 298 1138 5.22 / 388.89 5 130
Average= 5.12
(KJ/cycle)

Cycle 74 GMT 8/11/2024 5: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 31 15.00 407 189 0.19 / 378.67 6 7
2 7 2005.92 40 14.69 2956 1737 1.93 / 380.40 7 20
3 13 1806.48 20 14.67 2734 802 2.73 / 381.21 5 24
4 13 1295.24 20 14.69 2104 618 3.35 / 381.82 5 30
5 13 746.84 20 14.79 1391 411 3.76 / 382.24 5 38
6 13 101.12 20 15.00 483 145 3.90 / 382.38 5 37
7 13 59.24 20 15.01 418 125 4.03 / 382.51 5 23
8 8 -0.08 255 14.98 306 1169 5.20 / 383.67 5 129
Average= 5.12
(KJ/cycle)

Cycle 73 GMT 28/10/2024 20:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 32 14.99 404 194 0.19 / 373.58 6 13
2 7 2005.04 40 14.70 2938 1728 1.92 / 375.31 13 22
3 13 1701.40 20 14.69 2586 760 2.68 / 376.07 5 27
4 13 1289.88 20 14.71 2067 608 3.29 / 376.68 5 30
5 13 651.56 20 14.83 1250 371 3.66 / 377.05 5 38
6 13 111.64 20 15.00 499 150 3.81 / 377.20 5 34
7 13 66.72 20 15.01 427 128 3.94 / 377.33 5 36
8 8 -0.08 253 14.98 303 1148 5.09 / 378.48 5 135
Average= 5.11
(KJ/cycle)

Cycle 72 GMT 18/10/2024 12:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 32 15.01 398 191 0.19 / 368.45 6 6
2 7 2004.80 40 14.69 2949 1733 1.92 / 370.19 6 22
3 13 1812.76 20 14.68 2716 797 2.72 / 370.98 5 25
4 13 1273.40 20 14.70 2059 605 3.33 / 371.59 5 30
5 13 747.52 20 14.79 1379 408 3.73 / 372.00 5 35
6 13 112.32 20 15.01 487 146 3.88 / 372.14 5 30
7 13 61.16 20 15.02 402 121 4.00 / 372.26 5 33
8 8 0.04 255 14.98 295 1127 5.13 / 373.39 5 143
Average= 5.11
(KJ/cycle)

Cycle 71 GMT 8/10/2024 4:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 32 15.00 418 201 0.20 / 363.32 6 7
2 7 2004.08 40 14.69 2939 1727 1.93 / 365.04 7 23
3 13 1805.76 20 14.68 2710 796 2.72 / 365.84 5 26
4 13 1183.72 20 14.72 1935 570 3.29 / 366.41 5 32
5 13 874.20 20 14.76 1544 456 3.75 / 366.87 5 36
6 13 105.96 20 15.01 484 145 3.89 / 367.01 5 23
7 13 59.64 20 15.02 402 121 4.01 / 367.13 5 14
8 8 -0.04 255 14.99 296 1131 5.15 / 368.26 5 137
Average= 5.11
(KJ/cycle)

Cycle 70 GMT 27/ 9/2024 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 32 15.02 407 196 0.20 / 358.12 6 7
2 7 2004.28 40 14.70 2949 1734 1.93 / 359.85 7 25
3 13 1916.80 20 14.67 2846 835 2.76 / 360.69 5 27
4 13 1276.40 20 14.71 2052 604 3.37 / 361.29 5 29
5 13 726.96 20 14.81 1358 402 3.77 / 361.70 5 35
6 13 106.44 20 15.01 487 146 3.92 / 361.84 5 29
7 13 59.32 20 15.03 409 123 4.04 / 361.96 5 40
8 8 -0.08 257 14.99 299 1152 5.19 / 363.12 5 137
Average= 5.11
(KJ/cycle)

Cycle 69 GMT 17/ 9/2024 11:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 32 15.02 409 197 0.20 / 352.81 6 8
2 7 2015.64 40 14.69 2971 1746 1.94 / 354.56 8 22
3 13 1933.28 20 14.66 2886 846 2.79 / 355.40 5 28
4 13 1492.08 20 14.66 2350 689 3.48 / 356.09 5 35
5 13 836.28 20 14.78 1509 446 3.92 / 356.54 5 38
6 13 110.00 20 15.02 487 146 4.07 / 356.68 5 35
7 13 68.60 20 15.03 422 127 4.20 / 356.81 5 22
8 8 0.00 250 15.00 297 1114 5.31 / 357.92 5 131
Average= 5.11
(KJ/cycle)

Cycle 68 GMT 7/ 9/2024 2:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 32 15.01 406 195 0.20 / 347.54 6 7
2 7 2004.36 40 14.71 2949 1735 1.93 / 349.27 7 22
3 13 1909.52 20 14.68 2837 833 2.76 / 350.11 5 24
4 13 1473.96 20 14.68 2303 676 3.44 / 350.78 5 30
5 13 696.84 20 14.83 1303 386 3.83 / 351.17 5 37
6 13 144.08 20 15.01 537 161 3.99 / 351.33 5 36
7 13 79.40 20 15.03 435 131 4.12 / 351.46 5 41
8 8 0.00 257 15.00 299 1153 5.27 / 352.61 5 154
Average= 5.11
(KJ/cycle)

Cycle 67 GMT 27/ 8/2024 18:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 31 15.03 395 184 0.18 / 342.24 6 6
2 7 2004.68 40 14.70 2947 1733 1.92 / 343.97 19 22
3 13 1911.04 20 14.67 2843 834 2.75 / 344.80 5 24
4 13 1160.36 20 14.74 1914 564 3.32 / 345.37 5 33
5 13 839.76 20 14.78 1500 443 3.76 / 345.81 5 37
6 13 274.80 20 14.96 730 218 3.98 / 346.03 5 34
7 13 76.96 20 15.02 442 133 4.11 / 346.16 5 33
8 8 -0.28 257 14.99 307 1183 5.29 / 347.34 5 155
Average= 5.11
(KJ/cycle)

Cycle 66 GMT 17/ 8/2024 10:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 31 15.03 401 187 0.19 / 337.05 6 8
2 7 2002.20 40 14.71 2948 1735 1.92 / 338.79 8 22
3 13 1908.64 20 14.68 2835 832 2.75 / 339.62 5 22
4 13 1365.92 20 14.70 2166 637 3.39 / 340.26 5 29
5 13 701.96 20 14.83 1325 393 3.78 / 340.65 5 37
6 13 155.08 20 15.01 552 166 3.95 / 340.82 5 33
7 13 53.68 20 15.05 391 118 4.07 / 340.93 5 16
8 8 0.00 253 15.01 294 1116 5.18 / 342.05 5 130
Average= 5.11
(KJ/cycle)

Cycle 65 GMT 7/ 8/2024 2:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 31 15.03 407 190 0.19 / 331.89 6 7
2 7 2003.52 41 14.70 2955 1781 1.97 / 333.67 7 21
3 13 1803.80 20 14.69 2718 799 2.77 / 334.47 5 27
4 13 1279.60 20 14.72 2056 605 3.37 / 335.08 5 31
5 13 733.68 20 14.82 1360 403 3.78 / 335.48 5 36
6 13 106.80 20 15.04 475 143 3.92 / 335.62 5 27
7 13 64.28 20 15.04 411 124 4.04 / 335.75 5 28
8 8 -0.16 253 15.02 295 1121 5.17 / 336.87 5 140
Average= 5.10
(KJ/cycle)

Cycle 64 GMT 27/ 7/2024 18:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 31 15.03 414 193 0.19 / 326.72 6 11
2 7 2004.20 40 14.71 2948 1735 1.93 / 328.46 11 22
3 13 1906.60 20 14.69 2850 837 2.76 / 329.30 5 26
4 13 1062.08 20 14.78 1790 529 3.29 / 329.82 5 34
5 13 868.48 20 14.79 1544 457 3.75 / 330.28 5 34
6 13 131.64 20 15.03 530 159 3.91 / 330.44 5 30
7 13 78.96 20 15.05 428 129 4.04 / 330.57 5 27
8 8 -0.04 255 15.02 296 1134 5.17 / 331.70 5 147
Average= 5.10
(KJ/cycle)

Cycle 63 GMT 17/ 7/2024 10:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 31 15.05 397 185 0.19 / 321.52 6 6
2 7 2001.76 40 14.71 2953 1738 1.92 / 323.26 6 22
3 13 1903.76 20 14.69 2824 830 2.75 / 324.09 5 23
4 13 1165.56 20 14.76 1914 565 3.32 / 324.66 5 31
5 13 742.44 20 14.83 1376 408 3.73 / 325.06 5 34
6 13 186.56 20 15.01 604 181 3.91 / 325.25 5 40
7 13 48.84 20 15.06 389 117 4.02 / 325.36 5 25
8 8 -0.08 255 15.01 305 1167 5.19 / 326.53 5 142
Average= 5.10
(KJ/cycle)

Cycle 62 GMT 7/ 7/2024 2:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 31 15.05 403 188 0.19 / 316.39 6 7
2 7 2007.24 40 14.71 2958 1740 1.93 / 318.14 7 21
3 13 1908.56 20 14.69 2846 836 2.76 / 318.97 5 24
4 13 1254.16 20 14.74 2039 601 3.37 / 319.57 5 31
5 13 624.32 20 14.88 1224 364 3.73 / 319.94 5 39
6 13 111.00 20 15.05 488 147 3.88 / 320.08 5 34
7 13 60.04 20 15.06 405 122 4.00 / 320.21 5 26
8 8 0.04 253 15.03 298 1133 5.13 / 321.34 5 135
Average= 5.10
(KJ/cycle)

Cycle 61 GMT 26/ 6/2024 18: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 31 15.06 410 191 0.19 / 311.22 6 6
2 7 2005.40 40 14.72 2951 1738 1.93 / 312.96 6 20
3 13 1910.44 20 14.69 2846 836 2.77 / 313.79 5 25
4 13 1175.00 20 14.76 1937 572 3.34 / 314.36 5 33
5 13 760.72 20 14.84 1400 416 3.75 / 314.78 5 35
6 13 110.04 20 15.06 487 147 3.90 / 314.93 5 30
7 13 60.92 20 15.07 410 124 4.02 / 315.05 5 31
8 8 -0.04 255 15.03 302 1157 5.18 / 316.21 5 160
Average= 5.10
(KJ/cycle)

Cycle 60 GMT 16/ 6/2024 9:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 31 15.06 411 192 0.19 / 306.00 6 7
2 7 2005.68 40 14.72 2976 1752 1.94 / 307.76 7 20
3 13 1918.48 20 14.69 2873 844 2.79 / 308.60 5 25
4 13 1174.28 20 14.77 1937 572 3.36 / 309.17 5 29
5 13 762.00 20 14.85 1413 420 3.78 / 309.59 5 36
6 13 123.44 20 15.06 517 156 3.94 / 309.75 5 34
7 13 37.84 20 15.08 376 113 4.05 / 309.86 5 18
8 8 0.00 255 15.04 304 1166 5.22 / 311.03 5 133
Average= 5.10
(KJ/cycle)

Cycle 59 GMT 6/ 6/2024 1:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 31 15.06 413 193 0.19 / 300.83 6 10
2 7 2002.84 40 14.72 2967 1747 1.94 / 302.58 24 19
3 13 1803.48 20 14.70 2741 806 2.75 / 303.38 5 23
4 13 1161.64 20 14.77 1944 574 3.32 / 303.96 5 29
5 13 660.00 20 14.88 1278 380 3.70 / 304.34 5 36
6 13 124.36 20 15.06 531 160 3.86 / 304.50 5 35
7 13 36.96 20 15.08 387 117 3.98 / 304.61 5 58
8 8 0.00 253 15.04 315 1199 5.18 / 305.81 5 147
Average= 5.10
(KJ/cycle)

Cycle 58 GMT 26/ 5/2024 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 31 15.06 415 194 0.19 / 295.75 6 6
2 7 2005.16 40 14.72 2940 1731 1.92 / 297.48 6 22
3 13 1804.84 20 14.71 2721 801 2.73 / 298.28 5 27
4 13 1147.32 20 14.79 1895 561 3.29 / 298.84 5 32
5 13 626.28 20 14.90 1223 364 3.65 / 299.20 5 36
6 13 91.52 20 15.07 473 143 3.79 / 299.35 5 33
7 13 21.12 20 15.09 363 110 3.90 / 299.46 5 26
8 8 -0.12 250 15.04 314 1181 5.08 / 300.64 5 133
Average= 5.10
(KJ/cycle)

Cycle 57 GMT 16/ 5/2024 8:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 31 15.07 416 194 0.19 / 290.30 6 6
2 7 2011.04 40 14.73 2951 1739 1.93 / 292.04 6 23
3 13 1914.64 20 14.70 2855 839 2.77 / 292.88 5 22
4 13 1356.24 20 14.74 2166 639 3.41 / 293.52 5 30
5 13 1032.84 20 14.78 1758 520 3.93 / 294.04 5 33
6 13 230.80 20 15.03 667 201 4.13 / 294.24 5 38
7 13 27.80 20 15.10 368 111 4.24 / 294.35 5 44
8 8 -0.08 255 15.04 313 1200 5.44 / 295.55 5 136
Average= 5.10
(KJ/cycle)

Cycle 56 GMT 6/ 5/2024 0:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 31 15.08 413 193 0.19 / 285.06 6 6
2 7 2002.40 40 14.73 2957 1742 1.94 / 286.80 6 21
3 13 1905.96 20 14.70 2844 836 2.77 / 287.64 5 25
4 13 1333.80 20 14.75 2141 632 3.40 / 288.27 5 29
5 13 687.12 20 14.89 1308 390 3.79 / 288.66 5 37
6 13 81.28 20 15.09 460 139 3.93 / 288.80 5 37
7 13 24.76 20 15.10 366 111 4.04 / 288.91 5 33
8 8 -0.12 253 15.05 315 1199 5.24 / 290.11 5 162
Average= 5.09
(KJ/cycle)

Cycle 55 GMT 25/ 4/2024 16:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 31 15.08 418 195 0.20 / 279.89 6 9
2 7 2003.76 40 14.73 2966 1748 1.94 / 281.64 9 23
3 13 1703.44 20 14.73 2611 769 2.71 / 282.41 5 28
4 13 1385.64 20 14.73 2207 650 3.36 / 283.06 5 33
5 13 630.72 20 14.91 1237 369 3.73 / 283.43 5 35
6 13 67.92 20 15.10 435 131 3.86 / 283.56 5 40
7 13 37.44 20 15.10 387 117 3.98 / 283.68 5 34
8 8 -0.08 253 15.06 313 1193 5.17 / 284.87 5 142
Average= 5.09
(KJ/cycle)

Cycle 54 GMT 15/ 4/2024 8:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 31 15.09 412 193 0.19 / 274.66 6 6
2 7 2001.28 40 14.72 2958 1742 1.93 / 276.40 6 24
3 13 1702.88 20 14.73 2602 767 2.70 / 277.17 5 26
4 13 1284.44 20 14.75 2099 619 3.32 / 277.79 5 30
5 13 729.08 20 14.88 1375 409 3.73 / 278.20 5 35
6 13 171.44 20 15.06 594 179 3.91 / 278.38 5 38
7 13 38.12 20 15.10 393 119 4.03 / 278.50 5 43
8 8 -0.16 253 15.06 315 1200 5.23 / 279.70 5 137
Average= 5.09
(KJ/cycle)

Cycle 53 GMT 5/ 4/2024 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 31 15.09 415 194 0.19 / 269.47 6 6
2 7 2006.48 40 14.74 2960 1745 1.94 / 271.21 6 23
3 13 1814.84 20 14.72 2724 802 2.74 / 272.02 5 26
4 13 1280.24 20 14.77 2073 612 3.35 / 272.63 5 32
5 13 654.24 20 14.92 1266 378 3.73 / 273.01 5 37
6 13 109.36 20 15.09 504 152 3.88 / 273.16 5 37
7 13 32.80 20 15.11 383 116 4.00 / 273.27 5 42
8 8 -0.12 253 15.06 314 1196 5.20 / 274.47 5 140
Average= 5.08
(KJ/cycle)

Cycle 52 GMT 25/ 3/2024 15:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 31 15.09 415 194 0.19 / 264.27 6 11
2 7 2003.48 40 14.73 2955 1741 1.94 / 266.01 11 22
3 13 1803.92 20 14.72 2721 801 2.74 / 266.81 5 27
4 13 1278.88 20 14.78 2057 608 3.34 / 267.42 5 32
5 13 740.80 20 14.89 1380 411 3.76 / 267.83 5 37
6 13 88.56 20 15.10 472 143 3.90 / 267.97 5 34
7 13 24.92 20 15.12 372 112 4.01 / 268.09 5 30
8 8 -0.20 250 15.07 315 1187 5.20 / 269.27 5 141
Average= 5.08
(KJ/cycle)

Cycle 51 GMT 15/ 3/2024 7:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 31 15.09 430 201 0.20 / 258.95 6 11
2 7 2004.60 40 14.74 2958 1744 1.95 / 260.70 11 25
3 13 1714.24 20 14.74 2608 769 2.71 / 261.47 5 26
4 13 1298.84 20 14.78 2082 615 3.33 / 262.08 5 31
5 13 969.00 20 14.83 1683 499 3.83 / 262.58 5 35
6 13 85.56 20 15.11 471 142 3.97 / 262.72 5 30
7 13 48.92 20 15.11 417 126 4.10 / 262.85 5 23
8 8 -0.16 253 15.07 322 1228 5.32 / 264.08 5 139
Average= 5.08
(KJ/cycle)

Cycle 50 GMT 4/ 3/2024 23:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 31 15.10 414 194 0.19 / 253.70 6 6
2 7 2002.04 40 14.74 2959 1745 1.94 / 255.45 17 22
3 13 1805.88 20 14.73 2725 803 2.74 / 256.25 5 25
4 13 1191.40 20 14.81 1956 579 3.32 / 256.83 5 32
5 13 776.08 20 14.89 1430 426 3.75 / 257.25 5 35
6 13 105.28 20 15.10 503 152 3.90 / 257.41 5 32
7 13 60.68 20 15.11 428 129 4.03 / 257.54 5 35
8 8 -0.12 253 15.08 319 1217 5.24 / 258.75 5 134
Average= 5.07
(KJ/cycle)

Cycle 49 GMT 23/ 2/2024 14:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 31 15.10 420 197 0.20 / 248.55 6 6
2 7 2003.68 40 14.73 2969 1749 1.95 / 250.30 6 24
3 13 1809.56 20 14.72 2743 808 2.75 / 251.10 5 26
4 13 1090.72 20 14.83 1853 550 3.30 / 251.65 5 33
5 13 687.40 20 14.92 1319 394 3.70 / 252.05 5 38
6 13 79.72 20 15.12 460 139 3.84 / 252.19 5 26
7 13 46.52 20 15.12 402 122 3.96 / 252.31 5 44
8 8 0.04 253 15.09 314 1199 5.16 / 253.51 5 153
Average= 5.07
(KJ/cycle)

Cycle 48 GMT 13/ 2/2024 6:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 31 15.11 415 194 0.19 / 243.29 6 6
2 7 2003.48 40 14.74 2945 1736 1.93 / 245.03 6 24
3 13 1799.64 20 14.73 2709 798 2.73 / 245.83 5 24
4 13 1361.84 20 14.77 2194 648 3.38 / 246.48 5 30
5 13 705.20 20 14.92 1342 400 3.78 / 246.88 5 37
6 13 87.32 20 15.12 472 143 3.92 / 247.02 5 32
7 13 49.88 20 15.13 413 125 4.05 / 247.14 5 29
8 8 -0.08 253 15.09 316 1206 5.25 / 248.35 5 134
Average= 5.07
(KJ/cycle)

Cycle 47 GMT 2/ 2/2024 22:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 31 15.12 426 200 0.20 / 238.04 6 7
2 7 2003.56 40 14.74 2950 1739 1.94 / 239.78 7 21
3 13 1905.00 20 14.72 2845 838 2.78 / 240.62 5 26
4 13 1257.56 20 14.80 2048 606 3.38 / 241.23 5 30
5 13 723.64 20 14.93 1359 406 3.79 / 241.63 5 38
6 13 95.44 20 15.13 484 146 3.94 / 241.78 5 27
7 13 53.84 20 15.13 416 126 4.06 / 241.90 5 32
8 8 -0.12 253 15.10 313 1196 5.26 / 243.10 5 142
Average= 5.06
(KJ/cycle)

Cycle 46 GMT 23/ 1/2024 14: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 31 15.12 420 197 0.20 / 232.73 6 6
2 7 2006.48 40 14.74 2965 1748 1.95 / 234.47 25 22
3 13 1910.36 20 14.72 2859 842 2.79 / 235.32 5 24
4 13 1353.72 20 14.79 2168 641 3.43 / 235.96 5 31
5 13 806.32 20 14.91 1469 438 3.87 / 236.39 5 38
6 13 73.68 20 15.14 448 136 4.00 / 236.53 5 30
7 13 40.12 20 15.14 396 120 4.12 / 236.65 5 20
8 8 -0.08 250 15.10 316 1193 5.31 / 237.84 5 131
Average= 5.06
(KJ/cycle)

Cycle 45 GMT 13/ 1/2024 5:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 31 15.13 406 190 0.19 / 227.46 6 6
2 7 2006.16 40 14.75 2973 1754 1.94 / 229.21 6 21
3 13 1911.92 20 14.72 2868 844 2.79 / 230.05 5 26
4 13 1157.68 20 14.84 1934 574 3.36 / 230.63 5 34
5 13 742.52 20 14.93 1392 416 3.78 / 231.04 5 35
6 13 94.72 20 15.13 482 146 3.92 / 231.19 5 30
7 13 54.44 20 15.14 420 127 4.05 / 231.32 5 28
8 8 -0.16 253 15.10 317 1211 5.26 / 232.53 5 160
Average= 5.05
(KJ/cycle)

Cycle 44 GMT 2/ 1/2024 21:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 31 15.13 423 198 0.20 / 222.37 6 7
2 7 2002.64 40 14.74 2970 1751 1.95 / 224.12 7 23
3 13 1704.76 20 14.76 2607 770 2.72 / 224.89 5 26
4 13 1184.76 20 14.83 1972 585 3.30 / 225.48 5 31
5 13 637.72 20 14.96 1247 373 3.68 / 225.85 5 39
6 13 69.80 20 15.15 439 133 3.81 / 225.98 5 16
7 13 41.56 20 15.15 394 119 3.93 / 226.10 5 26
8 8 -0.12 249 15.12 309 1163 5.09 / 227.27 5 131
Average= 5.05
(KJ/cycle)

Cycle 43 GMT 23/12/2023 13:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 31 15.13 417 196 0.20 / 217.15 6 14
2 7 2009.16 40 14.75 2967 1751 1.95 / 218.90 14 25
3 13 1916.00 20 14.73 2859 842 2.79 / 219.75 5 23
4 13 1165.04 20 14.85 1924 571 3.36 / 220.32 5 34
5 13 751.24 20 14.94 1398 418 3.78 / 220.74 5 38
6 13 103.80 20 15.14 488 148 3.93 / 220.88 5 31
7 13 31.40 20 15.16 376 114 4.04 / 221.00 5 49
8 8 -0.16 250 15.12 311 1176 5.21 / 222.17 5 137
Average= 5.05
(KJ/cycle)

Cycle 42 GMT 13/12/2023 4:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 31 15.13 416 195 0.20 / 211.87 6 6
2 7 2003.68 41 14.75 2958 1789 1.98 / 213.66 17 23
3 13 1906.56 20 14.74 2839 837 2.82 / 214.49 5 23
4 13 1242.08 20 14.84 2010 597 3.42 / 215.09 5 34
5 13 807.56 20 14.92 1469 438 3.86 / 215.53 5 36
6 13 82.68 20 15.15 460 139 4.00 / 215.67 5 34
7 13 22.88 20 15.17 357 108 4.10 / 215.78 5 33
8 8 -0.08 253 15.12 309 1182 5.29 / 216.96 5 132
Average= 5.05
(KJ/cycle)

Cycle 41 GMT 2/12/2023 20:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 31 15.16 415 195 0.20 / 206.70 6 6
2 7 2002.28 40 14.76 2955 1745 1.94 / 208.44 6 23
3 13 1800.68 20 14.76 2726 805 2.74 / 209.25 5 24
4 13 1158.28 20 14.86 1925 572 3.32 / 209.82 5 33
5 13 628.76 20 14.98 1232 369 3.69 / 210.19 5 37
6 13 92.80 20 15.15 485 147 3.83 / 210.34 5 34
7 13 53.56 20 15.16 419 127 3.96 / 210.46 5 35
8 8 -0.08 253 15.12 316 1209 5.17 / 211.67 5 145
Average= 5.04
(KJ/cycle)

Cycle 40 GMT 22/11/2023 12:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 31 15.15 411 193 0.19 / 201.48 6 7
2 7 2008.24 40 14.76 2971 1754 1.95 / 203.24 7 25
3 13 1919.64 20 14.74 2865 845 2.79 / 204.08 5 25
4 13 1292.40 20 14.83 2094 621 3.41 / 204.70 5 35
5 13 647.72 20 14.98 1264 379 3.79 / 205.08 5 38
6 13 77.84 20 15.17 446 135 3.93 / 205.22 5 32
7 13 48.72 20 15.17 400 121 4.05 / 205.34 5 37
8 8 -0.08 250 15.13 308 1165 5.21 / 206.50 5 134
Average= 5.04
(KJ/cycle)

Cycle 39 GMT 12/11/2023 4: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 31 15.15 410 193 0.19 / 196.35 6 6
2 7 2004.12 40 14.76 2962 1749 1.94 / 198.10 6 22
3 13 1698.44 20 14.77 2615 772 2.71 / 198.87 5 28
4 13 1187.84 20 14.85 1976 587 3.30 / 199.46 5 35
5 13 657.76 20 14.97 1286 385 3.69 / 199.84 5 36
6 13 72.08 20 15.17 446 135 3.82 / 199.98 5 42
7 13 38.84 20 15.17 388 118 3.94 / 200.09 5 27
8 8 -0.12 251 15.13 315 1196 5.13 / 201.29 5 153
Average= 5.03
(KJ/cycle)

Cycle 38 GMT 1/11/2023 19:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 31 15.16 418 196 0.20 / 191.15 6 6
2 7 2004.08 40 14.77 2947 1741 1.94 / 192.89 6 20
3 13 1816.84 20 14.77 2739 809 2.75 / 193.70 5 24
4 13 1289.72 20 14.84 2082 618 3.36 / 194.32 5 32
5 13 652.84 20 14.99 1271 381 3.75 / 194.70 5 37
6 13 106.68 20 15.16 497 151 3.90 / 194.85 5 41
7 13 59.24 20 15.17 418 127 4.02 / 194.98 5 44
8 8 -0.08 250 15.13 312 1180 5.20 / 196.16 5 140
Average= 5.03
(KJ/cycle)

Cycle 37 GMT 22/10/2023 11: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 31 15.16 428 201 0.20 / 186.06 6 7
2 7 2005.80 40 14.77 2959 1748 1.95 / 187.81 7 22
3 13 1711.24 20 14.78 2623 775 2.72 / 188.58 5 28
4 13 1094.72 20 14.89 1843 549 3.27 / 189.13 5 33
5 13 673.48 20 14.98 1296 388 3.66 / 189.52 5 39
6 13 73.96 20 15.17 450 137 3.80 / 189.66 5 29
7 13 20.48 20 15.19 359 109 3.91 / 189.77 5 36
8 8 -0.12 251 15.14 312 1186 5.09 / 190.95 5 162
Average= 5.03
(KJ/cycle)

Cycle 36 GMT 12/10/2023 2:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 31 15.16 424 199 0.20 / 180.89 6 6
2 7 2003.60 40 14.76 2948 1740 1.94 / 182.63 6 25
3 13 1703.64 20 14.80 2593 768 2.71 / 183.39 5 29
4 13 1177.08 20 14.87 1934 575 3.28 / 183.97 5 32
5 13 752.68 20 14.96 1397 418 3.70 / 184.39 5 39
6 13 94.04 20 15.17 483 147 3.85 / 184.53 5 36
7 13 50.60 20 15.18 413 125 3.97 / 184.66 5 43
8 8 0.04 250 15.14 317 1200 5.17 / 185.86 5 130
Average= 5.02
(KJ/cycle)

Cycle 35 GMT 1/10/2023 18:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 31 15.17 426 200 0.20 / 175.66 6 12
2 7 2011.36 40 14.77 2970 1755 1.96 / 177.41 12 24
3 13 1913.72 20 14.76 2845 840 2.79 / 178.25 5 26
4 13 1245.80 20 14.86 2030 603 3.40 / 178.86 5 32
5 13 698.24 20 14.99 1332 399 3.80 / 179.26 5 37
6 13 84.00 20 15.18 461 140 3.94 / 179.40 5 35
7 13 25.00 20 15.20 362 110 4.05 / 179.51 5 8
8 8 -0.20 251 15.15 311 1183 5.23 / 180.69 5 157
Average= 5.02
(KJ/cycle)

Cycle 34 GMT 21/ 9/2023 10:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 31 15.17 416 196 0.20 / 170.42 6 7
2 7 2003.76 40 14.77 2972 1756 1.95 / 172.18 7 23
3 13 1906.16 20 14.76 2846 840 2.79 / 173.02 5 24
4 13 1168.72 20 14.89 1943 579 3.37 / 173.60 5 35
5 13 741.36 20 14.97 1388 416 3.79 / 174.01 5 40
6 13 92.52 20 15.18 475 144 3.93 / 174.16 5 33
7 13 29.36 20 15.20 372 113 4.04 / 174.27 5 40
8 8 -0.12 250 15.15 314 1189 5.23 / 175.46 5 131
Average= 5.01
(KJ/cycle)

Cycle 33 GMT 11/ 9/2023 2:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 31 15.17 423 199 0.20 / 165.10 6 6
2 7 2006.72 40 14.78 2956 1748 1.95 / 166.85 6 24
3 13 1908.68 20 14.77 2845 840 2.79 / 167.69 5 26
4 13 1256.52 20 14.87 2053 611 3.40 / 168.30 5 35
5 13 828.52 20 14.95 1500 448 3.85 / 168.75 5 37
6 13 82.92 20 15.19 463 141 3.99 / 168.89 5 27
7 13 45.04 20 15.19 399 121 4.11 / 169.01 5 21
8 8 -0.12 253 15.15 317 1215 5.32 / 170.23 5 149
Average= 5.01
(KJ/cycle)

Cycle 32 GMT 31/ 8/2023 17:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 31 15.16 428 201 0.20 / 159.80 6 7
2 7 2004.76 40 14.79 2953 1747 1.95 / 161.55 7 23
3 13 1910.20 20 14.77 2850 842 2.79 / 162.39 5 25
4 13 1371.36 20 14.85 2175 646 3.44 / 163.04 5 32
5 13 830.20 20 14.96 1501 449 3.89 / 163.48 5 36
6 13 82.00 20 15.20 457 139 4.02 / 163.62 5 29
7 8 0.00 272 15.17 310 1279 5.30 / 164.90 5 132
Average= 5.00
(KJ/cycle)

Cycle 31 GMT 21/ 8/2023 9:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 31 15.18 422 199 0.20 / 154.52 6 6
2 7 2001.72 40 14.79 2955 1748 1.95 / 156.27 6 23
3 13 1808.20 20 14.79 2729 807 2.75 / 157.08 5 27
4 13 1273.36 20 14.87 2064 614 3.37 / 157.69 5 34
5 13 632.56 20 15.02 1242 373 3.74 / 158.06 5 38
6 13 187.52 20 15.16 610 185 3.93 / 158.25 5 37
7 13 17.40 20 15.20 360 109 4.04 / 158.36 5 40
8 8 -0.24 253 15.15 324 1242 5.28 / 159.60 5 141
Average= 4.99
(KJ/cycle)

Cycle 30 GMT 11/ 8/2023 1:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 30 15.17 431 196 0.20 / 149.29 6 7
2 7 2002.00 40 14.80 2946 1744 1.94 / 151.03 7 24
3 13 1706.28 20 14.81 2601 770 2.71 / 151.80 5 30
4 13 1392.88 20 14.84 2205 654 3.37 / 152.45 5 34
5 13 738.16 20 14.99 1380 414 3.78 / 152.87 5 38
6 13 57.60 20 15.21 424 129 3.91 / 153.00 5 37
7 13 31.96 20 15.21 382 116 4.02 / 153.11 5 36
8 8 -0.12 250 15.16 319 1209 5.23 / 154.32 5 145
Average= 4.98
(KJ/cycle)

Cycle 29 GMT 31/ 7/2023 16:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 31 15.19 424 200 0.20 / 144.14 6 6
2 7 2005.04 40 14.79 2965 1754 1.95 / 145.90 6 25
3 13 1697.64 20 14.82 2598 770 2.72 / 146.67 5 26
4 13 1272.96 20 14.87 2073 617 3.34 / 147.28 5 31
5 13 632.80 20 15.02 1245 374 3.71 / 147.66 5 41
6 13 55.52 20 15.21 419 127 3.84 / 147.78 5 47
7 13 17.00 20 15.22 358 109 3.95 / 147.89 5 44
8 8 -0.12 248 15.16 318 1196 5.15 / 149.09 5 135
Average= 4.97
(KJ/cycle)

Cycle 28 GMT 21/ 7/2023 8:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 31 15.19 429 202 0.20 / 139.04 6 7
2 7 2001.88 40 14.80 2945 1743 1.95 / 140.79 7 25
3 13 1805.24 20 14.80 2721 805 2.75 / 141.59 5 27
4 13 1171.88 20 14.91 1946 580 3.33 / 142.17 5 34
5 13 538.84 20 15.06 1116 336 3.67 / 142.51 5 38
6 13 57.40 20 15.21 419 127 3.79 / 142.64 5 35
7 13 35.44 20 15.22 382 116 3.91 / 142.75 5 26
8 8 -0.20 250 15.17 314 1191 5.10 / 143.94 5 149
Average= 4.96
(KJ/cycle)

Cycle 27 GMT 11/ 7/2023 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 31 15.19 421 198 0.20 / 133.91 6 7
2 7 2005.20 40 14.81 2939 1741 1.94 / 135.65 7 23
3 13 1909.04 20 14.79 2852 844 2.78 / 136.49 5 24
4 13 1160.64 20 14.92 1915 571 3.35 / 137.06 5 32
5 13 538.04 20 15.07 1110 335 3.69 / 137.40 5 39
6 13 60.80 20 15.22 425 129 3.82 / 137.53 5 32
7 13 38.80 20 15.22 393 120 3.94 / 137.65 5 36
8 8 -0.04 248 15.18 317 1193 5.13 / 138.84 5 130
Average= 4.96
(KJ/cycle)

Cycle 26 GMT 30/ 6/2023 15:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 31 15.20 426 201 0.20 / 128.68 6 7
2 7 2003.24 40 14.80 2949 1746 1.95 / 130.42 7 22
3 13 1908.24 20 14.79 2862 847 2.79 / 131.27 5 27
4 13 1264.24 20 14.90 2041 608 3.40 / 131.88 5 31
5 13 623.56 20 15.04 1237 372 3.77 / 132.25 5 39
6 13 48.84 20 15.22 412 125 3.90 / 132.38 5 36
7 13 28.44 20 15.22 379 115 4.01 / 132.49 5 37
8 8 -0.12 251 15.17 320 1218 5.23 / 133.71 5 148
Average= 4.95
(KJ/cycle)

Cycle 25 GMT 20/ 6/2023 7:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 31 15.20 420 198 0.20 / 123.30 6 7
2 7 2008.56 40 14.81 2954 1750 1.95 / 125.05 7 22
3 13 1913.40 20 14.80 2850 844 2.79 / 125.90 5 24
4 13 1466.32 20 14.84 2308 685 3.48 / 126.58 5 32
5 13 783.44 20 15.00 1442 433 3.91 / 127.01 5 39
6 13 61.04 20 15.22 429 131 4.04 / 127.15 5 34
7 13 34.44 20 15.23 386 118 4.16 / 127.26 5 31
8 8 -0.16 253 15.18 316 1214 5.37 / 128.48 5 140
Average= 4.94
(KJ/cycle)

Cycle 24 GMT 9/ 6/2023 23:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 31 15.20 422 199 0.20 / 117.98 6 6
2 7 2004.16 40 14.82 2947 1747 1.95 / 119.73 6 23
3 13 1908.64 20 14.80 2857 846 2.79 / 120.57 5 27
4 13 1355.64 20 14.88 2163 644 3.44 / 121.22 5 30
5 13 797.92 20 15.00 1446 434 3.87 / 121.65 5 38
6 13 68.20 20 15.23 438 133 4.00 / 121.78 5 36
7 13 41.52 20 15.23 395 120 4.12 / 121.90 5 33
8 8 -0.04 253 15.19 313 1203 5.33 / 123.11 5 144
Average= 4.92
(KJ/cycle)

Cycle 23 GMT 30/ 5/2023 15:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 31 15.20 424 200 0.20 / 112.62 6 6
2 7 2004.32 40 14.82 2971 1761 1.96 / 114.39 6 21
3 13 1906.88 20 14.81 2863 848 2.81 / 115.23 5 28
4 13 1247.52 20 14.92 2036 608 3.42 / 115.84 5 31
5 13 905.12 20 14.97 1595 478 3.89 / 116.32 5 36
6 13 53.16 20 15.23 421 128 4.02 / 116.45 5 37
7 13 33.24 20 15.23 391 119 4.14 / 116.57 5 32
8 8 -0.16 250 15.18 320 1214 5.36 / 117.78 5 133
Average= 4.91
(KJ/cycle)

Cycle 22 GMT 20/ 5/2023 7:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 31 15.22 411 194 0.19 / 107.32 6 6
2 7 2002.60 40 14.82 2943 1745 1.94 / 109.07 6 22
3 13 1905.16 20 14.81 2849 844 2.78 / 109.91 5 26
4 13 1272.44 20 14.91 2088 623 3.41 / 110.53 5 32
5 13 731.88 20 15.03 1366 411 3.82 / 110.94 5 37
6 13 73.56 20 15.22 453 138 3.95 / 111.08 5 37
7 13 43.20 20 15.23 406 124 4.08 / 111.21 5 34
8 8 -0.24 250 15.19 321 1219 5.30 / 112.42 5 135
Average= 4.89
(KJ/cycle)

Cycle 21 GMT 9/ 5/2023 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 31 15.21 426 201 0.20 / 102.04 6 6
2 7 2009.48 40 14.82 2962 1756 1.96 / 103.80 6 24
3 13 1918.36 20 14.81 2865 849 2.81 / 104.65 5 27
4 13 1359.68 20 14.89 2164 644 3.45 / 105.29 5 29
5 13 598.80 20 15.07 1195 360 3.81 / 105.65 5 38
6 13 73.36 20 15.23 456 139 3.95 / 105.79 5 37
7 13 46.88 20 15.23 416 127 4.08 / 105.92 5 36
8 8 -0.12 250 15.19 319 1211 5.29 / 107.13 5 137
Average= 4.87
(KJ/cycle)

Cycle 20 GMT 29/ 4/2023 14:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 31 15.21 424 200 0.20 / 96.83 6 6
2 7 2004.00 40 14.82 2965 1758 1.96 / 98.59 6 25
3 13 1697.96 20 14.86 2604 774 2.73 / 99.36 5 29
4 13 1266.72 20 14.91 2059 614 3.35 / 99.98 5 35
5 13 719.92 20 15.03 1368 411 3.76 / 100.39 5 37
6 13 44.84 20 15.24 409 125 3.88 / 100.51 5 33
7 13 28.84 20 15.24 383 117 4.00 / 100.63 5 35
8 8 -0.24 248 15.19 322 1213 5.21 / 101.84 5 144
Average= 4.85
(KJ/cycle)

Cycle 19 GMT 19/ 4/2023 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 31 15.21 420 198 0.20 / 91.56 6 6
2 7 2005.04 40 14.83 2958 1755 1.95 / 93.31 6 24
3 13 1911.28 20 14.83 2844 844 2.80 / 94.15 5 25
4 13 1059.08 20 14.98 1799 539 3.34 / 94.69 5 34
5 13 752.76 20 15.03 1410 424 3.76 / 95.12 5 37
6 13 54.08 20 15.24 434 132 3.89 / 95.25 5 33
7 13 31.16 20 15.24 397 121 4.01 / 95.37 5 36
8 8 -0.24 250 15.19 332 1261 5.27 / 96.63 5 130
Average= 4.83
(KJ/cycle)

Cycle 18 GMT 8/ 4/2023 22:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 31 15.22 428 202 0.20 / 86.28 6 6
2 7 2005.44 40 14.83 2961 1756 1.96 / 88.03 6 21
3 13 1704.72 20 14.86 2611 776 2.73 / 88.81 5 27
4 13 1381.88 20 14.89 2201 655 3.39 / 89.46 5 30
5 13 703.08 20 15.05 1332 401 3.79 / 89.86 5 38
6 13 70.88 20 15.24 453 138 3.93 / 90.00 5 34
7 13 38.96 20 15.24 403 123 4.05 / 90.13 5 35
8 8 -0.28 250 15.20 324 1231 5.28 / 91.36 5 136
Average= 4.81
(KJ/cycle)

Cycle 17 GMT 29/ 3/2023 13:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 31 15.21 434 205 0.20 / 81.06 6 6
2 7 2002.36 40 14.84 2958 1756 1.96 / 82.81 6 24
3 13 1801.92 20 14.85 2736 813 2.77 / 83.63 5 26
4 13 1151.84 20 14.96 1937 580 3.35 / 84.21 5 34
5 13 738.88 20 15.04 1377 414 3.77 / 84.62 5 38
6 13 54.52 20 15.25 421 128 3.90 / 84.75 5 34
7 13 33.00 20 15.25 389 119 4.01 / 84.87 5 33
8 8 -0.08 248 15.20 320 1206 5.22 / 86.07 5 138
Average= 4.78
(KJ/cycle)

Cycle 16 GMT 19/ 3/2023 5:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 31 15.22 434 205 0.20 / 75.78 6 7
2 7 2005.52 40 14.84 2956 1755 1.96 / 77.53 7 23
3 13 1907.24 20 14.84 2853 847 2.81 / 78.38 5 26
4 13 1333.76 20 14.92 2146 640 3.45 / 79.02 5 32
5 13 570.68 20 15.09 1158 349 3.80 / 79.37 5 37
6 13 67.44 20 15.25 443 135 3.93 / 79.50 5 35
7 13 38.20 20 15.25 398 121 4.05 / 79.63 5 33
8 8 0.04 250 15.21 323 1228 5.28 / 80.85 5 147
Average= 4.76
(KJ/cycle)

Cycle 15 GMT 8/ 3/2023 21:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 31 15.23 419 198 0.20 / 70.55 6 7
2 7 2001.36 40 14.85 2960 1758 1.96 / 72.31 7 24
3 13 1807.24 20 14.86 2721 809 2.76 / 73.12 5 26
4 13 1159.24 20 14.96 1927 577 3.34 / 73.70 5 36
5 13 633.08 20 15.07 1248 376 3.72 / 74.07 5 39
6 13 53.00 20 15.25 430 131 3.85 / 74.21 5 34
7 13 30.08 20 15.25 394 120 3.97 / 74.33 5 35
8 8 -0.28 248 15.20 331 1248 5.22 / 75.57 5 134
Average= 4.72
(KJ/cycle)

Cycle 14 GMT 26/ 2/2023 13:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 30 15.23 430 196 0.20 / 65.25 6 6
2 7 2001.72 40 14.85 2964 1761 1.96 / 67.02 18 23
3 13 1612.80 20 14.90 2497 744 2.70 / 67.76 5 27
4 13 1414.88 20 14.90 2246 669 3.37 / 68.43 5 30
5 13 758.96 20 15.04 1420 427 3.80 / 68.86 5 37
6 13 58.28 20 15.26 434 132 3.93 / 68.99 5 34
7 13 33.52 20 15.26 396 121 4.05 / 69.11 5 33
8 8 -0.04 250 15.21 328 1247 5.30 / 70.36 5 135
Average= 4.69
(KJ/cycle)

Cycle 13 GMT 16/ 2/2023 4:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 30 15.23 428 196 0.20 / 59.82 6 6
2 7 2005.48 40 14.85 2956 1756 1.95 / 61.57 6 21
3 13 1915.68 20 14.84 2866 851 2.80 / 62.42 5 26
4 13 1371.68 20 14.92 2190 653 3.46 / 63.08 5 33
5 13 804.96 20 15.03 1485 446 3.90 / 63.52 5 37
6 13 68.20 20 15.25 460 140 4.04 / 63.66 5 35
7 13 38.40 20 15.26 410 125 4.17 / 63.79 5 36
8 8 -0.16 250 15.21 334 1270 5.44 / 65.06 5 137
Average= 4.65
(KJ/cycle)

Cycle 12 GMT 5/ 2/2023 20:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 30 15.23 428 196 0.20 / 54.54 6 6
2 7 2004.16 41 14.85 2975 1811 2.01 / 56.35 6 23
3 13 1703.04 20 14.88 2626 781 2.79 / 57.13 5 26
4 13 1267.00 20 14.94 2064 617 3.41 / 57.75 5 33
5 13 610.60 20 15.09 1220 368 3.77 / 58.12 5 37
6 13 79.44 20 15.26 466 142 3.92 / 58.26 5 35
7 13 43.12 20 15.26 410 125 4.04 / 58.39 5 34
8 8 -0.08 248 15.22 327 1234 5.27 / 59.62 5 129
Average= 4.59
(KJ/cycle)

Cycle 11 GMT 26/ 1/2023 12:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 31 15.24 422 199 0.20 / 49.18 6 6
2 7 2003.96 40 14.86 2958 1758 1.96 / 50.94 6 21
3 13 1908.24 20 14.86 2853 848 2.81 / 51.78 5 25
4 13 1358.92 20 14.93 2177 650 3.46 / 52.43 5 32
5 13 696.84 20 15.07 1338 403 3.86 / 52.84 5 38
6 13 81.12 20 15.26 473 144 4.00 / 52.98 5 33
7 13 46.76 20 15.26 416 127 4.13 / 53.11 5 32
8 8 0.00 250 15.22 325 1237 5.37 / 54.35 5 138
Average= 4.53
(KJ/cycle)

Cycle 10 GMT 16/ 1/2023 3:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 30 15.24 442 202 0.20 / 44.02 6 6
2 7 2004.64 41 14.86 2955 1800 2.00 / 45.82 6 21
3 13 1704.20 20 14.90 2601 775 2.78 / 46.59 5 26
4 13 1177.44 20 14.97 1952 584 3.36 / 47.18 5 33
5 13 549.88 20 15.11 1135 343 3.70 / 47.52 5 38
6 13 77.44 20 15.26 466 142 3.85 / 47.66 5 35
7 8 -0.04 267 15.23 324 1318 5.16 / 48.98 5 133
Average= 4.45
(KJ/cycle)

Cycle 9 GMT 5/ 1/2023 19:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 30 15.24 422 193 0.19 / 38.67 6 6
2 7 2003.76 40 14.87 2976 1770 1.96 / 40.44 21 23
3 13 1923.64 20 14.86 2894 860 2.82 / 41.30 5 26
4 13 1163.48 20 14.98 1941 582 3.40 / 41.88 5 34
5 13 646.08 20 15.09 1268 383 3.79 / 42.26 5 37
6 13 106.16 20 15.25 512 156 3.94 / 42.42 5 36
7 13 55.88 20 15.26 437 133 4.08 / 42.55 5 34
8 8 -0.12 251 15.22 330 1261 5.34 / 43.81 5 154
Average= 4.38
(KJ/cycle)

Cycle 8 GMT 26/12/2022 10:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 30 15.23 427 195 0.20 / 33.51 6 7
2 7 2002.72 40 14.87 2970 1767 1.96 / 35.27 7 24
3 13 1705.84 20 14.91 2604 777 2.74 / 36.05 5 27
4 13 1178.28 20 14.98 1952 585 3.32 / 36.63 5 32
5 13 541.12 20 15.12 1123 340 3.66 / 36.97 5 39
6 13 70.96 20 15.27 450 137 3.80 / 37.11 5 36
7 13 38.20 20 15.27 401 122 3.92 / 37.23 5 32
8 8 -0.08 248 15.23 329 1243 5.17 / 38.48 5 143
Average= 4.28
(KJ/cycle)

Cycle 7 GMT 16/12/2022 2: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 29 15.25 430 190 0.19 / 28.15 6 9
2 3 1019.12 1 15.25 1782 27 0.22 / 28.18 5 23
3 7 2004.20 40 14.87 2980 1773 1.99 / 29.95 23 22
4 13 1809.32 20 14.89 2747 818 2.81 / 30.77 5 25
5 13 1157.88 20 14.99 1930 579 3.39 / 31.35 5 34
6 13 835.28 20 15.04 1520 457 3.84 / 31.81 5 37
7 13 79.24 20 15.27 469 143 3.99 / 31.95 5 31
8 13 45.48 20 15.27 413 126 4.11 / 32.07 5 25
9 8 -0.04 250 15.23 325 1237 5.35 / 33.31 5 145
Average= 4.16
(KJ/cycle)

Cycle 6 GMT 5/12/2022 17:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 29 15.25 420 186 0.19 / 22.99 6 6
2 7 2003.52 40 14.89 2965 1766 1.95 / 24.76 22 23
3 13 1699.72 20 14.92 2606 778 2.73 / 25.54 5 28
4 13 1088.20 20 15.01 1827 548 3.28 / 26.09 5 33
5 13 662.64 20 15.09 1282 387 3.66 / 26.47 5 36
6 13 73.04 20 15.27 452 138 3.80 / 26.61 5 42
7 13 41.00 20 15.28 405 124 3.93 / 26.73 5 22
8 8 -0.12 248 15.23 325 1228 5.15 / 27.96 5 132
Average= 3.99
(KJ/cycle)

Cycle 5 GMT 25/11/2022 8:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 31 15.26 407 193 0.19 / 17.76 6 6
2 3 933.44 -1 15.57 5 0 0.00 / 17.76 6 6
3 7 2005.68 40 14.90 2947 1756 1.95 / 19.51 6 20
4 13 1907.32 20 14.89 2838 845 2.79 / 20.36 5 27
5 13 1142.76 20 15.01 1890 567 3.36 / 20.93 5 32
6 13 721.80 20 15.08 1362 411 3.77 / 21.34 5 39
7 13 88.36 20 15.27 466 142 3.91 / 21.48 5 35
8 13 52.60 20 15.28 412 126 4.04 / 21.60 5 35
9 8 -0.08 249 15.24 317 1203 5.24 / 22.81 5 140
Average= 3.80
(KJ/cycle)

Cycle 4 GMT 15/11/2022 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 28 15.26 403 172 0.17 / 13.37 6 6
2 7 1500.80 40 15.06 2319 1397 1.57 / 14.76 15 25
3 13 1411.24 20 15.05 2210 665 2.23 / 15.43 5 27
4 13 992.88 20 15.09 1693 511 2.75 / 15.94 5 34
5 13 361.16 20 15.22 849 258 3.00 / 16.20 5 38
6 13 78.40 20 15.30 443 136 3.14 / 16.34 5 35
7 8 0.00 263 15.27 306 1229 4.37 / 17.56 5 139
Average= 3.51
(KJ/cycle)

Cycle 3 GMT 13/11/2022 13:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 28 15.26 413 176 0.18 / 8.98 6 6
2 7 1507.16 40 15.06 2336 1407 1.58 / 10.38 6 25
3 13 1422.00 20 15.05 2227 670 2.25 / 11.05 5 29
4 13 1008.08 20 15.08 1702 513 2.77 / 11.57 5 30
5 13 445.68 20 15.19 969 294 3.06 / 11.86 5 39
6 13 71.40 20 15.30 427 131 3.19 / 11.99 5 35
7 13 20.24 20 15.31 345 106 3.30 / 12.10 5 27
8 8 0.00 242 15.26 297 1097 4.39 / 13.20 5 139
Average= 3.30
(KJ/cycle)

Cycle 2 GMT 12/11/2022 3: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 31 15.27 411 195 0.19 / 4.62 6 6
2 3 914.08 -1 15.58 5 0 0.00 / 4.62 6 6
3 7 1472.20 40 15.07 2299 1386 1.58 / 6.01 6 24
4 13 1383.60 20 15.06 2204 664 2.24 / 6.67 5 28
5 13 977.40 20 15.09 1682 508 2.75 / 7.18 5 33
6 13 342.64 20 15.22 829 252 3.00 / 7.43 5 39
7 13 73.16 20 15.30 424 130 3.13 / 7.56 5 29
8 13 17.12 20 15.31 345 106 3.24 / 7.67 5 30
9 8 0.00 242 15.27 307 1134 4.37 / 8.80 5 134
Average= 2.93
(KJ/cycle)

Cycle 1 GMT 10/11/2022 16:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 31 15.44 379 181 0.18 / 1.79 6 7
2 3 912.00 -1 15.59 5 0 0.00 / 1.79 6 7
3 7 937.40 40 15.19 1598 971 1.15 / 2.77 7 30
4 13 429.48 20 15.27 934 285 1.44 / 3.05 5 37
5 13 100.24 20 15.34 456 140 1.58 / 3.19 5 37
6 8 0.08 263 15.31 307 1236 2.81 / 4.43 5 145
Average= 2.21
(KJ/cycle)

Cycle 0 GMT 10/11/2022 5:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 137.80 30 15.59 426 199 0.20 / 0.20 6 8
2 7 147.44 40 15.57 430 268 0.47 / 0.47 8 8
3 13 100.60 20 15.56 370 115 0.58 / 0.58 6 8
4 13 60.64 20 15.55 318 99 0.68 / 0.68 6 9
5 8 -0.04 257 15.50 234 932 1.61 / 1.61 6 137
Average= 1.61
(KJ/cycle)