SIO Argo Site:
Pump Diagnostics Page   



Serial= 3110 WMO= 4903412

Return

←PreviousNext→

Cycle 70 GMT 15/ 3/2023 15:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 24 15.17 480 175 0.17 / 194.45 2 2
2 7 1904.04 38 14.65 2957 1646 1.82 / 196.09 2 3
3 13 1195.88 18 14.86 2062 552 2.37 / 196.64 2 4
4 13 726.48 18 14.99 1410 380 2.75 / 197.02 2 4
5 13 194.88 18 15.18 627 171 2.92 / 197.20 2 4
6 8 0.16 165 15.21 317 796 3.72 / 197.99 2 8
Average= 10.42 (KJ/cycle)

Cycle 69 GMT 5/ 3/2023 20:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 24 15.18 490 179 0.18 / 190.62 2 3
2 7 1902.16 39 14.66 2968 1697 1.88 / 192.31 2 3
3 13 1231.28 18 14.88 2109 565 2.44 / 192.88 2 3
4 13 829.04 18 14.97 1569 423 2.86 / 193.30 2 4
5 13 215.20 18 15.19 662 181 3.04 / 193.48 2 4
6 8 -0.16 165 15.22 314 789 3.83 / 194.27 2 10
Average= 10.79 (KJ/cycle)

Cycle 68 GMT 24/ 2/2023 0:33: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 24 15.19 492 179 0.18 / 186.80 2 3
2 7 1901.56 38 14.67 2956 1648 1.83 / 188.45 2 3
3 13 1329.20 18 14.84 2244 599 2.43 / 189.05 2 4
4 13 771.16 18 15.00 1495 404 2.83 / 189.45 2 4
5 13 231.32 18 15.19 684 187 3.02 / 189.64 2 4
6 8 0.16 165 15.23 318 799 3.82 / 190.44 2 12
Average= 11.20 (KJ/cycle)

Cycle 67 GMT 14/ 2/2023 4:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 24 15.19 499 182 0.18 / 182.98 2 2
2 7 1903.96 38 14.67 2967 1654 1.84 / 184.64 2 3
3 13 1338.28 18 14.84 2260 604 2.44 / 185.24 2 3
4 13 772.20 18 15.01 1493 403 2.84 / 185.64 2 4
5 13 226.84 18 15.19 682 186 3.03 / 185.83 2 4
6 8 0.00 165 15.22 316 794 3.82 / 186.62 2 9
Average= 11.66 (KJ/cycle)

Cycle 66 GMT 4/ 2/2023 8:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 24 15.20 495 181 0.18 / 179.26 2 2
2 7 1902.00 38 14.68 2963 1653 1.83 / 180.91 2 3
3 13 1171.60 18 14.89 2035 545 2.38 / 181.45 2 4
4 13 738.00 18 15.01 1440 389 2.77 / 181.84 2 4
5 13 152.84 18 15.22 572 157 2.92 / 182.00 2 4
6 8 0.04 165 15.24 318 800 3.72 / 182.80 2 8
Average= 12.19 (KJ/cycle)

Cycle 65 GMT 25/ 1/2023 12:40: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 24 15.21 497 181 0.18 / 175.05 2 2
2 7 1901.80 50 14.64 2962 2168 2.35 / 177.22 2 3
3 13 901.12 18 14.99 1657 447 2.80 / 177.66 2 4
4 13 335.96 18 15.17 852 233 3.03 / 177.90 2 4
5 8 0.08 165 15.26 324 816 3.85 / 178.71 2 8
6 14 0.08 75 15.23 318 363 4.21 / 179.08 2 15
Average= 12.79 (KJ/cycle)

Cycle 64 GMT 15/ 1/2023 16:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 24 15.21 501 183 0.18 / 171.10 2 3
2 7 1903.64 51 14.65 2974 2222 2.40 / 173.32 2 3
3 13 899.84 18 14.97 1685 454 2.86 / 173.77 2 5
4 13 454.64 18 15.13 1042 284 3.14 / 174.06 2 5
5 8 0.36 165 15.26 322 811 3.95 / 174.87 2 9
Average= 13.45 (KJ/cycle)

Cycle 63 GMT 5/ 1/2023 21:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 24 15.19 495 180 0.18 / 167.18 2 2
2 7 1903.76 50 14.66 2977 2182 2.36 / 169.36 2 3
3 13 909.76 18 14.99 1679 453 2.82 / 169.81 2 4
4 13 467.32 18 15.13 1056 288 3.10 / 170.10 2 4
5 8 0.24 165 15.25 323 813 3.92 / 170.91 2 9
Average= 14.24 (KJ/cycle)

Cycle 62 GMT 27/12/2022 1:33: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 24 15.23 495 181 0.18 / 162.90 2 2
2 7 1903.44 50 14.66 2969 2176 2.36 / 165.07 2 3
3 13 919.80 18 14.98 1694 457 2.81 / 165.53 2 4
4 13 481.28 18 15.12 1062 289 3.10 / 165.82 2 4
5 8 0.24 165 15.26 323 813 3.92 / 166.63 2 11
6 14 0.24 75 15.22 321 366 4.28 / 167.00 3 10
Average= 15.18 (KJ/cycle)

Cycle 61 GMT 17/12/2022 5:47: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 24 15.23 472 173 0.17 / 159.03 2 2
2 7 1904.68 50 14.68 2973 2182 2.35 / 161.22 2 4
3 13 910.76 18 14.99 1679 453 2.81 / 161.67 2 4
4 13 358.00 18 15.20 887 243 3.05 / 161.91 2 4
5 8 -0.16 165 15.27 319 804 3.85 / 162.71 2 8
Average= 16.27 (KJ/cycle)

Cycle 60 GMT 7/12/2022 10: 6:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 24 15.23 510 186 0.19 / 154.56 2 2
2 3 1020.48 1 15.24 1890 29 0.22 / 154.59 2 3
3 7 1902.72 74 14.61 2972 3213 3.43 / 157.80 2 5
4 13 377.52 18 15.19 915 250 3.68 / 158.05 2 4
5 8 0.28 165 15.28 320 807 4.49 / 158.86 2 7
Average= 17.65 (KJ/cycle)

Cycle 59 GMT 27/11/2022 12:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 24 15.24 490 179 0.18 / 150.11 2 2
2 3 1016.72 1 15.23 1904 29 0.21 / 150.14 2 3
3 7 1910.80 74 14.58 2976 3211 3.42 / 153.35 2 3
4 13 252.28 18 15.24 722 198 3.62 / 153.55 2 4
5 8 0.20 165 15.28 327 824 4.44 / 154.38 2 8
Average= 19.30 (KJ/cycle)

Cycle 58 GMT 17/11/2022 13:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 24 15.24 498 182 0.18 / 145.51 2 2
2 7 1917.40 74 14.57 2997 3231 3.41 / 148.74 2 3
3 13 389.80 18 15.18 948 259 3.67 / 149.00 2 4
4 13 46.52 18 15.28 407 112 3.78 / 149.11 2 4
5 8 0.00 165 15.27 325 819 4.60 / 149.93 2 10
Average= 21.42 (KJ/cycle)

Cycle 57 GMT 7/11/2022 13:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 24 15.24 470 172 0.17 / 141.71 2 2
2 7 1507.52 74 14.78 2447 2676 2.85 / 144.39 2 4
3 13 111.08 18 15.31 508 140 2.99 / 144.53 2 4
4 8 0.24 165 15.29 318 802 3.79 / 145.33 2 9
Average= 24.22 (KJ/cycle)

Cycle 56 GMT 6/11/2022 14: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 24 15.24 491 180 0.18 / 137.86 2 2
2 3 1016.28 1 15.26 1866 28 0.21 / 137.89 2 3
3 7 1514.80 74 14.78 2470 2701 2.91 / 140.59 2 3
4 13 141.24 18 15.29 555 153 3.06 / 140.74 2 4
5 8 0.28 165 15.29 315 795 3.86 / 141.54 2 9
Average= 28.31 (KJ/cycle)

Cycle 55 GMT 5/11/2022 14:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 23 15.31 510 180 0.18 / 133.63 2 2
2 3 1040.28 1 15.19 1924 29 0.21 / 133.66 2 3
3 7 1516.56 74 14.78 2457 2687 2.90 / 136.35 2 5
4 13 130.36 18 15.29 546 150 3.05 / 136.50 2 4
5 8 0.24 165 15.29 324 817 3.86 / 137.32 2 13
6 14 0.24 75 15.26 318 364 4.23 / 137.68 2 12
Average= 34.42 (KJ/cycle)

Cycle 54 GMT 4/11/2022 14:41: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 23 15.29 498 175 0.18 / 130.59 2 2
2 3 1038.32 1 15.18 1914 29 0.20 / 130.62 2 3
3 7 1008.16 74 15.03 1793 1994 2.20 / 132.61 2 4
4 8 0.00 165 15.35 332 841 3.04 / 133.45 2 9
Average= 44.48 (KJ/cycle)

Cycle 53 GMT 1/11/2022 18:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 11 15.33 509 86 0.09 / 127.13 2 2
2 10 1084.80 6 15.09 1957 177 0.26 / 127.31 2 3
3 10 1135.68 3 15.09 2031 92 0.35 / 127.40 2 3
4 3 1136.32 4 15.06 2031 122 0.48 / 127.52 2 3
5 3 1061.96 2 15.10 1981 60 0.54 / 127.58 2 3
6 7 1017.20 74 15.01 1799 1998 2.54 / 129.58 2 4
7 8 0.04 165 15.34 330 835 3.37 / 130.42 2 10
Average= 65.21 (KJ/cycle)

Cycle 52 GMT 30/10/2022 2:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1009.72 11 15.07 1869 310 0.31 / 123.48 2 2
2 2 1020.32 24 14.99 1846 664 0.97 / 124.14 2 3
3 2 1020.32 6 14.96 1858 167 1.14 / 124.31 2 3
4 3 517.48 -9 15.59 0 0 0.83 / 124.31 2 3
5 3 793.00 -4 15.62 1 0 0.83 / 124.31 2 3
6 7 931.20 75 15.08 1675 1894 3.04 / 126.20 2 4
7 8 0.04 165 15.36 332 841 3.88 / 127.05 2 11
Average= 127.05 (KJ/cycle)

Cycle 50 GMT 27/10/2022 2:59: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 24 15.23 487 178 0.18 / 118.80 2 2
2 7 1913.68 75 14.58 2973 3251 3.43 / 122.05 2 3
3 13 257.76 18 15.23 740 203 3.63 / 122.25 2 4
4 13 24.32 18 15.30 370 102 3.73 / 122.35 2 4
5 8 0.36 165 15.27 323 814 4.55 / 123.17 2 10
Average= 4.74 (KJ/cycle)

Cycle 49 GMT 17/10/2022 3:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 24 15.24 476 174 0.17 / 114.23 2 2
2 7 1917.20 74 14.60 2982 3222 3.40 / 117.46 2 3
3 13 369.44 18 15.20 908 248 3.64 / 117.70 2 4
4 13 43.40 18 15.32 396 109 3.75 / 117.81 2 3
5 8 0.16 165 15.29 320 807 4.56 / 118.62 2 7
Average= 4.74 (KJ/cycle)

Cycle 48 GMT 7/10/2022 3:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 24 15.24 496 181 0.18 / 109.64 2 2
2 7 1913.00 75 14.60 2979 3262 3.44 / 112.90 2 3
3 13 360.88 18 15.19 896 245 3.69 / 113.15 2 4
4 13 21.76 18 15.32 367 101 3.79 / 113.25 2 4
5 8 0.12 165 15.28 322 812 4.60 / 114.06 2 10
Average= 4.75 (KJ/cycle)

Cycle 47 GMT 27/ 9/2022 3:59: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 24 15.25 478 175 0.17 / 105.12 2 2
2 7 1918.04 74 14.59 2982 3220 3.39 / 108.34 2 3
3 13 264.16 18 15.24 745 204 3.60 / 108.55 2 4
4 13 27.88 18 15.32 374 103 3.70 / 108.65 2 4
5 8 0.00 165 15.28 320 807 4.51 / 109.46 2 10
Average= 4.76 (KJ/cycle)

Cycle 46 GMT 17/ 9/2022 4:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 24 15.24 485 177 0.18 / 100.56 2 3
2 7 1915.88 74 14.60 2978 3217 3.39 / 103.78 2 3
3 13 376.72 18 15.20 919 251 3.65 / 104.03 2 4
4 13 25.24 18 15.32 373 103 3.75 / 104.14 2 4
5 8 0.04 165 15.28 323 814 4.56 / 104.95 2 9
Average= 4.77 (KJ/cycle)

Cycle 45 GMT 7/ 9/2022 4:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 24 15.24 492 180 0.18 / 95.97 2 2
2 7 1910.64 75 14.60 2967 3249 3.43 / 99.22 2 4
3 13 366.80 18 15.20 907 248 3.68 / 99.47 2 4
4 13 35.80 18 15.30 387 107 3.78 / 99.58 2 4
5 8 0.16 165 15.27 321 809 4.59 / 100.39 2 10
Average= 4.78 (KJ/cycle)

Cycle 44 GMT 28/ 8/2022 4:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 24 15.23 486 178 0.18 / 91.42 2 2
2 7 1914.08 74 14.61 2980 3222 3.40 / 94.64 2 4
3 13 364.76 18 15.22 901 247 3.65 / 94.89 2 4
4 13 19.64 18 15.32 361 100 3.75 / 94.98 2 4
5 8 0.20 165 15.28 321 809 4.56 / 95.79 2 10
Average= 4.79 (KJ/cycle)

Cycle 43 GMT 18/ 8/2022 5:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 24 15.23 491 179 0.18 / 86.83 2 3
2 7 1909.72 75 14.60 2968 3250 3.43 / 90.08 2 3
3 13 358.56 18 15.20 886 242 3.67 / 90.32 2 4
4 13 34.04 18 15.32 387 107 3.78 / 90.43 2 4
5 8 0.04 165 15.28 322 812 4.59 / 91.24 2 11
Average= 4.80 (KJ/cycle)

Cycle 42 GMT 8/ 8/2022 5:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 24 15.24 479 175 0.18 / 82.29 2 2
2 7 1909.28 74 14.62 2959 3201 3.38 / 85.50 2 4
3 13 370.04 18 15.19 905 247 3.62 / 85.74 2 4
4 13 22.88 18 15.32 366 101 3.72 / 85.84 2 4
5 8 0.12 165 15.28 319 804 4.53 / 86.65 2 10
Average= 4.81 (KJ/cycle)

Cycle 41 GMT 29/ 7/2022 6:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 24 15.25 485 178 0.18 / 77.77 2 2
2 7 1908.32 75 14.62 2962 3248 3.43 / 81.02 2 4
3 13 240.48 18 15.26 703 193 3.62 / 81.21 2 4
4 13 45.24 18 15.31 395 109 3.73 / 81.32 2 4
5 8 0.08 165 15.28 318 802 4.53 / 82.12 2 9
Average= 4.83 (KJ/cycle)

Cycle 40 GMT 19/ 7/2022 6:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 24 15.25 490 179 0.18 / 73.22 2 2
2 7 1911.00 74 14.62 2968 3211 3.39 / 76.43 2 4
3 13 370.44 18 15.20 903 247 3.64 / 76.68 2 4
4 13 40.80 18 15.32 398 110 3.75 / 76.79 2 4
5 8 0.16 165 15.28 319 804 4.55 / 77.59 2 10
Average= 4.85 (KJ/cycle)

Cycle 39 GMT 9/ 7/2022 6:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 24 15.25 496 182 0.18 / 68.68 2 2
2 7 1910.72 74 14.63 2973 3219 3.40 / 71.89 2 3
3 13 367.36 18 15.21 901 247 3.65 / 72.14 2 4
4 13 22.92 18 15.33 362 100 3.75 / 72.24 2 4
5 8 0.08 165 15.30 316 798 4.54 / 73.04 2 9
Average= 4.87 (KJ/cycle)

Cycle 38 GMT 29/ 6/2022 7:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 24 15.26 484 177 0.18 / 64.11 2 2
2 7 1902.96 74 14.62 2970 3213 3.39 / 67.32 2 6
3 13 343.96 18 15.24 871 239 3.63 / 67.56 2 4
4 13 17.72 18 15.34 370 102 3.73 / 67.66 2 4
5 8 0.08 165 15.29 330 833 4.56 / 68.49 2 9
Average= 4.89 (KJ/cycle)

Cycle 37 GMT 19/ 6/2022 7:43: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 24 15.26 496 182 0.18 / 59.63 2 2
2 7 1905.20 74 14.64 2958 3205 3.39 / 62.83 2 3
3 13 243.52 18 15.28 710 195 3.58 / 63.02 2 4
4 13 22.00 18 15.34 365 101 3.68 / 63.13 2 4
5 8 0.24 165 15.29 319 805 4.49 / 63.93 2 9
Average= 4.92 (KJ/cycle)

Cycle 36 GMT 9/ 6/2022 8: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 24 15.25 491 180 0.18 / 55.12 2 2
2 7 1916.92 74 14.64 2982 3231 3.41 / 58.35 2 3
3 13 237.04 18 15.27 697 192 3.60 / 58.54 2 4
4 13 23.12 18 15.32 366 101 3.70 / 58.64 2 4
5 8 0.00 165 15.29 318 802 4.51 / 59.44 2 9
Average= 4.95 (KJ/cycle)

Cycle 35 GMT 30/ 5/2022 8:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 24 15.26 486 178 0.18 / 50.56 2 2
2 7 1911.88 74 14.64 2971 3219 3.40 / 53.78 2 6
3 13 360.96 18 15.21 893 244 3.64 / 54.02 2 4
4 13 17.16 18 15.33 357 99 3.74 / 54.12 2 3
5 8 0.00 165 15.30 324 818 4.56 / 54.94 2 9
Average= 4.99 (KJ/cycle)

Cycle 34 GMT 20/ 5/2022 8:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 24 15.27 488 179 0.18 / 46.13 2 2
2 7 1908.48 75 14.63 2961 3249 3.43 / 49.38 2 5
3 13 230.92 18 15.26 697 191 3.62 / 49.57 2 4
4 8 0.00 165 15.30 320 808 4.43 / 50.38 2 9
Average= 5.04 (KJ/cycle)

Cycle 33 GMT 10/ 5/2022 9: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 24 15.27 497 182 0.18 / 41.69 2 2
2 7 1905.64 74 14.65 2965 3214 3.40 / 44.90 2 4
3 13 358.60 18 15.23 891 244 3.64 / 45.14 2 4
4 8 0.16 165 15.32 320 809 4.45 / 45.95 2 8
Average= 5.11 (KJ/cycle)

Cycle 32 GMT 30/ 4/2022 9:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 24 15.26 496 182 0.18 / 37.21 2 2
2 7 1904.44 74 14.64 2974 3222 3.40 / 40.43 2 3
3 13 354.40 18 15.21 891 244 3.65 / 40.67 2 4
4 8 0.16 165 15.31 329 831 4.48 / 41.50 2 7
Average= 5.19 (KJ/cycle)

Cycle 31 GMT 20/ 4/2022 9:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 23 15.25 509 179 0.18 / 32.78 2 2
2 3 1017.32 1 15.25 1903 29 0.21 / 32.81 2 2
3 7 1903.96 74 14.63 2967 3212 3.42 / 36.02 2 3
4 13 231.52 18 15.27 687 189 3.61 / 36.21 2 4
5 8 0.28 165 15.31 323 816 4.42 / 37.03 2 9
Average= 5.29 (KJ/cycle)

Cycle 30 GMT 10/ 4/2022 10:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 22 15.24 512 172 0.17 / 28.22 2 2
2 3 1047.44 1 15.19 1920 29 0.20 / 28.25 2 3
3 7 1908.56 75 14.64 2984 3276 3.48 / 31.52 2 3
4 13 342.56 18 15.23 878 241 3.72 / 31.76 2 4
5 8 0.12 165 15.31 331 836 4.55 / 32.60 2 8
Average= 5.43 (KJ/cycle)

Cycle 29 GMT 31/ 3/2022 10:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 29 15.26 481 213 0.21 / 23.75 2 2
2 3 797.32 -4 15.60 0 0 0.00 / 23.75 2 2
3 3 924.68 -1 15.64 0 0 0.00 / 23.75 2 2
4 7 1901.64 74 14.65 2963 3212 3.43 / 26.96 2 3
5 13 363.00 18 15.24 898 246 3.67 / 27.21 2 4
6 8 0.36 165 15.30 332 838 4.51 / 28.05 2 8
Average= 5.61 (KJ/cycle)

Cycle 28 GMT 21/ 3/2022 11:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 23 15.24 483 169 0.17 / 19.86 2 2
2 7 1507.76 75 14.81 2441 2711 2.88 / 22.58 2 3
3 13 104.24 18 15.33 502 139 3.02 / 22.71 2 3
4 8 0.20 165 15.30 326 823 3.84 / 23.54 2 8
Average= 5.88 (KJ/cycle)

Cycle 27 GMT 20/ 3/2022 11:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 22 15.25 487 163 0.16 / 15.65 2 2
2 3 1037.16 1 15.20 1916 29 0.19 / 15.68 2 3
3 7 1509.84 74 14.82 2447 2684 2.88 / 18.37 2 3
4 13 112.24 18 15.32 512 141 3.02 / 18.51 2 3
5 8 -0.16 165 15.30 325 820 3.84 / 19.33 2 7
6 14 -0.16 75 15.26 321 367 4.21 / 19.70 3 10
Average= 6.57 (KJ/cycle)

Cycle 26 GMT 19/ 3/2022 11:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 32 15.27 487 238 0.24 / 11.88 2 2
2 3 726.04 -5 15.61 0 0 0.00 / 11.88 2 2
3 3 877.44 -2 15.63 0 0 0.00 / 11.88 2 2
4 7 1507.40 74 14.81 2439 2673 2.91 / 14.55 2 3
5 13 106.16 18 15.31 491 135 3.05 / 14.68 2 3
6 8 -0.04 165 15.30 319 805 3.85 / 15.49 2 10
Average= 7.75 (KJ/cycle)

Cycle 25 GMT 18/ 3/2022 12:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 554.12 25 15.21 1133 431 0.43 / 8.88 2 2
2 3 882.40 -2 15.59 1 0 0.00 / 8.88 2 2
3 3 954.76 -1 15.62 1 0 0.00 / 8.88 2 2
4 7 986.88 74 15.00 1739 1930 2.36 / 10.81 2 4
5 8 0.00 165 15.31 326 824 3.18 / 11.64 2 10
Average= 11.64 (KJ/cycle)

Cycle 23 GMT 18/ 3/2022 0:19: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 836.92 23 15.21 1603 561 0.56 / 5.60 2 3
2 10 1020.60 2 15.24 1872 57 0.62 / 5.66 2 3
3 7 1005.32 74 15.03 1773 1972 2.59 / 7.63 2 4
4 8 0.16 165 15.36 326 826 3.42 / 8.45 2 9
Average= 8.45 (KJ/cycle)

Cycle 4 GMT 31/12/2021 18:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 951.00 27 15.17 1757 720 0.72 / 2.31 2 3
2 3 931.48 -1 15.68 0 0 0.00 / 2.31 2 3
3 3 963.12 -1 15.69 0 0 0.00 / 2.31 2 3
4 7 998.40 74 15.06 1748 1948 2.67 / 4.26 2 4
5 8 -0.08 165 15.35 307 778 3.45 / 5.04 2 9
Average= 5.04 (KJ/cycle)

Cycle 0 GMT 29/12/2021 7:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.92 26 15.61 386 157 0.16 / 0.16 2 3
2 7 83.24 75 15.57 396 462 0.62 / 0.62 2 3
3 8 0.24 240 15.54 261 973 1.59 / 1.59 2 12
Average= 1.59 (KJ/cycle)