SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 33 | 14.84 | 502 | 246 | 0.25 / 706.19 | 6 | 46 |
2 | 7 | 1573.16 | 41 | 14.57 | 2468 | 1474 | 1.72 / 707.66 | 36 | 60 |
3 | 13 | 1500.16 | 20 | 14.57 | 2370 | 691 | 2.41 / 708.36 | 6 | 66 |
4 | 13 | 1294.52 | 20 | 14.56 | 2136 | 622 | 3.03 / 708.98 | 6 | 71 |
5 | 13 | 603.92 | 20 | 14.74 | 1192 | 351 | 3.38 / 709.33 | 6 | 71 |
6 | 8 | 0.28 | 227 | 14.87 | 350 | 1181 | 4.57 / 710.51 | 6 | 133 |
Average= | 7.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 33 | 14.85 | 523 | 256 | 0.26 / 701.49 | 6 | 46 |
2 | 7 | 1621.48 | 40 | 14.56 | 2534 | 1476 | 1.73 / 702.96 | 46 | 61 |
3 | 13 | 1549.84 | 20 | 14.55 | 2462 | 716 | 2.45 / 703.68 | 6 | 65 |
4 | 13 | 1348.92 | 20 | 14.53 | 2213 | 643 | 3.09 / 704.32 | 6 | 72 |
5 | 13 | 587.52 | 20 | 14.74 | 1173 | 346 | 3.44 / 704.67 | 6 | 70 |
6 | 13 | 135.20 | 20 | 14.89 | 561 | 167 | 3.60 / 704.83 | 6 | 67 |
7 | 8 | 0.08 | 208 | 14.86 | 359 | 1110 | 4.71 / 705.94 | 6 | 131 |
Average= | 7.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.72 | 33 | 14.84 | 543 | 266 | 0.27 / 697.02 | 6 | 48 |
2 | 7 | 1555.44 | 40 | 14.60 | 2453 | 1433 | 1.70 / 698.45 | 35 | 61 |
3 | 13 | 1482.24 | 20 | 14.59 | 2373 | 692 | 2.39 / 699.14 | 6 | 63 |
4 | 13 | 1278.80 | 20 | 14.57 | 2120 | 618 | 3.01 / 699.76 | 6 | 71 |
5 | 13 | 429.72 | 20 | 14.82 | 954 | 283 | 3.29 / 700.04 | 6 | 67 |
6 | 8 | 0.24 | 227 | 14.89 | 351 | 1186 | 4.48 / 701.23 | 6 | 133 |
Average= | 7.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 33 | 14.84 | 530 | 260 | 0.26 / 692.64 | 6 | 48 |
2 | 7 | 1385.12 | 40 | 14.65 | 2256 | 1322 | 1.58 / 693.96 | 48 | 67 |
3 | 13 | 1331.24 | 20 | 14.64 | 2197 | 643 | 2.22 / 694.61 | 6 | 69 |
4 | 13 | 1127.56 | 20 | 14.63 | 1923 | 563 | 2.79 / 695.17 | 6 | 74 |
5 | 13 | 474.56 | 20 | 14.81 | 1032 | 306 | 3.09 / 695.48 | 6 | 75 |
6 | 13 | 135.24 | 20 | 14.90 | 565 | 168 | 3.26 / 695.64 | 6 | 71 |
7 | 8 | 0.16 | 203 | 14.88 | 367 | 1109 | 4.37 / 696.75 | 6 | 141 |
Average= | 7.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 33 | 14.84 | 522 | 256 | 0.26 / 688.31 | 6 | 43 |
2 | 3 | 1026.20 | 1 | 14.96 | 1789 | 27 | 0.28 / 688.34 | 6 | 42 |
3 | 7 | 1393.92 | 40 | 14.65 | 2261 | 1325 | 1.61 / 689.66 | 42 | 66 |
4 | 13 | 1328.60 | 20 | 14.65 | 2177 | 638 | 2.25 / 690.30 | 6 | 69 |
5 | 13 | 1139.52 | 20 | 14.62 | 1961 | 573 | 2.82 / 690.88 | 6 | 73 |
6 | 13 | 488.56 | 20 | 14.80 | 1054 | 312 | 3.13 / 691.19 | 6 | 73 |
7 | 8 | -0.12 | 223 | 14.89 | 360 | 1195 | 4.33 / 692.38 | 6 | 129 |
Average= | 7.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 33 | 14.85 | 519 | 254 | 0.25 / 683.81 | 6 | 45 |
2 | 7 | 1452.04 | 40 | 14.63 | 2331 | 1364 | 1.62 / 685.17 | 45 | 65 |
3 | 13 | 1387.48 | 20 | 14.62 | 2252 | 658 | 2.28 / 685.83 | 6 | 70 |
4 | 13 | 1189.20 | 20 | 14.60 | 2017 | 589 | 2.87 / 686.42 | 6 | 74 |
5 | 13 | 417.84 | 20 | 14.82 | 957 | 284 | 3.15 / 686.70 | 6 | 72 |
6 | 13 | 56.36 | 20 | 14.93 | 452 | 135 | 3.28 / 686.84 | 6 | 70 |
7 | 13 | 40.00 | 20 | 14.93 | 430 | 128 | 3.41 / 686.97 | 6 | 72 |
8 | 8 | -0.24 | 186 | 14.88 | 366 | 1013 | 4.43 / 687.98 | 6 | 139 |
9 | 14 | -0.32 | 14 | 14.83 | 363 | 75 | 4.50 / 688.06 | 44 | -99 |
Average= | 7.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 33 | 14.86 | 519 | 255 | 0.25 / 679.47 | 6 | 42 |
2 | 7 | 1355.08 | 40 | 14.66 | 2215 | 1299 | 1.55 / 680.77 | 42 | 67 |
3 | 13 | 1304.92 | 20 | 14.65 | 2151 | 630 | 2.18 / 681.40 | 6 | 68 |
4 | 13 | 1213.44 | 20 | 14.62 | 2035 | 595 | 2.78 / 682.00 | 6 | 73 |
5 | 13 | 550.40 | 20 | 14.78 | 1132 | 335 | 3.11 / 682.33 | 6 | 77 |
6 | 13 | 17.16 | 20 | 14.95 | 395 | 118 | 3.23 / 682.45 | 6 | 72 |
7 | 8 | 0.24 | 203 | 14.89 | 366 | 1106 | 4.34 / 683.56 | 6 | 139 |
Average= | 7.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 33 | 14.85 | 530 | 260 | 0.26 / 675.39 | 6 | 42 |
2 | 7 | 1281.48 | 40 | 14.71 | 2119 | 1247 | 1.51 / 676.63 | 42 | 67 |
3 | 13 | 1223.72 | 20 | 14.70 | 2042 | 600 | 2.11 / 677.23 | 6 | 69 |
4 | 13 | 1031.40 | 20 | 14.68 | 1818 | 534 | 2.64 / 677.77 | 6 | 73 |
5 | 13 | 367.68 | 20 | 14.86 | 891 | 265 | 2.91 / 678.03 | 6 | 72 |
6 | 8 | 0.08 | 220 | 14.90 | 362 | 1187 | 4.09 / 679.22 | 6 | 129 |
Average= | 7.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 33 | 14.86 | 510 | 250 | 0.25 / 671.24 | 6 | 40 |
2 | 7 | 1291.28 | 40 | 14.70 | 2136 | 1256 | 1.51 / 672.50 | 57 | 68 |
3 | 13 | 1233.00 | 20 | 14.69 | 2063 | 606 | 2.11 / 673.10 | 6 | 69 |
4 | 13 | 1036.60 | 20 | 14.69 | 1791 | 526 | 2.64 / 673.63 | 6 | 72 |
5 | 13 | 379.48 | 20 | 14.85 | 909 | 270 | 2.91 / 673.90 | 6 | 75 |
6 | 13 | 26.60 | 20 | 14.95 | 410 | 123 | 3.03 / 674.02 | 6 | 73 |
7 | 8 | -0.12 | 203 | 14.90 | 365 | 1104 | 4.13 / 675.13 | 6 | 143 |
Average= | 7.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 33 | 14.85 | 521 | 255 | 0.26 / 666.98 | 6 | 43 |
2 | 7 | 1379.24 | 40 | 14.66 | 2232 | 1309 | 1.56 / 668.29 | 43 | 64 |
3 | 13 | 1317.60 | 20 | 14.65 | 2176 | 638 | 2.20 / 668.93 | 6 | 69 |
4 | 13 | 1117.96 | 20 | 14.64 | 1914 | 560 | 2.76 / 669.49 | 6 | 73 |
5 | 13 | 448.56 | 20 | 14.82 | 997 | 296 | 3.06 / 669.78 | 6 | 71 |
6 | 8 | 0.24 | 223 | 14.90 | 364 | 1209 | 4.27 / 670.99 | 6 | 129 |
Average= | 7.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 33 | 14.85 | 518 | 254 | 0.25 / 662.84 | 6 | 48 |
2 | 7 | 1329.68 | 40 | 14.68 | 2184 | 1282 | 1.54 / 664.12 | 48 | 68 |
3 | 13 | 1264.04 | 20 | 14.67 | 2103 | 617 | 2.15 / 664.74 | 6 | 73 |
4 | 13 | 1071.88 | 20 | 14.66 | 1845 | 541 | 2.69 / 665.28 | 6 | 74 |
5 | 13 | 302.88 | 20 | 14.87 | 808 | 240 | 2.93 / 665.52 | 6 | 74 |
6 | 8 | 0.08 | 223 | 14.90 | 363 | 1206 | 4.14 / 666.72 | 6 | 132 |
Average= | 7.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 32 | 14.87 | 508 | 242 | 0.24 / 658.52 | 6 | 37 |
2 | 3 | 1029.80 | 1 | 14.97 | 1778 | 27 | 0.27 / 658.55 | 6 | 60 |
3 | 7 | 1391.84 | 40 | 14.67 | 2261 | 1327 | 1.60 / 659.87 | 60 | 65 |
4 | 13 | 1328.84 | 20 | 14.66 | 2192 | 643 | 2.24 / 660.51 | 6 | 68 |
5 | 13 | 1039.20 | 20 | 14.66 | 1810 | 531 | 2.77 / 661.05 | 6 | 73 |
6 | 13 | 503.40 | 20 | 14.80 | 1061 | 314 | 3.08 / 661.36 | 6 | 69 |
7 | 13 | 12.48 | 20 | 14.95 | 388 | 116 | 3.20 / 661.48 | 6 | 66 |
8 | 8 | 0.00 | 206 | 14.89 | 361 | 1107 | 4.31 / 662.58 | 6 | 138 |
Average= | 7.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 33 | 14.86 | 514 | 252 | 0.25 / 654.17 | 6 | 38 |
2 | 3 | 964.48 | -1 | 15.31 | 11 | 0 | 0.00 / 654.17 | 6 | 38 |
3 | 7 | 1451.16 | 40 | 14.66 | 2332 | 1367 | 1.62 / 655.53 | 38 | 65 |
4 | 13 | 1384.16 | 20 | 14.65 | 2244 | 657 | 2.28 / 656.19 | 6 | 69 |
5 | 13 | 1093.36 | 20 | 14.65 | 1884 | 552 | 2.83 / 656.74 | 6 | 73 |
6 | 13 | 544.20 | 20 | 14.79 | 1129 | 334 | 3.16 / 657.08 | 6 | 74 |
7 | 8 | 0.00 | 227 | 14.90 | 355 | 1201 | 4.36 / 658.28 | 6 | 136 |
Average= | 7.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 33 | 14.87 | 509 | 250 | 0.25 / 649.09 | 6 | 40 |
2 | 7 | 1897.76 | 40 | 14.47 | 2884 | 1669 | 1.92 / 650.76 | 40 | 57 |
3 | 13 | 1802.44 | 20 | 14.47 | 2751 | 796 | 2.72 / 651.56 | 6 | 64 |
4 | 13 | 1391.40 | 20 | 14.50 | 2231 | 647 | 3.36 / 652.21 | 6 | 68 |
5 | 13 | 837.92 | 20 | 14.63 | 1510 | 442 | 3.80 / 652.65 | 6 | 74 |
6 | 13 | 70.32 | 20 | 14.93 | 454 | 136 | 3.94 / 652.78 | 6 | 72 |
7 | 8 | 0.04 | 212 | 14.88 | 358 | 1129 | 5.07 / 653.91 | 6 | 131 |
Average= | 7.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 34 | 14.88 | 511 | 259 | 0.26 / 643.90 | 6 | 39 |
2 | 7 | 2005.92 | 41 | 14.45 | 3010 | 1783 | 2.04 / 645.68 | 39 | 53 |
3 | 13 | 1916.32 | 20 | 14.44 | 2904 | 839 | 2.88 / 646.52 | 6 | 57 |
4 | 13 | 1391.80 | 20 | 14.48 | 2244 | 650 | 3.53 / 647.17 | 6 | 67 |
5 | 13 | 724.48 | 20 | 14.68 | 1362 | 400 | 3.93 / 647.57 | 6 | 76 |
6 | 13 | 72.04 | 20 | 14.93 | 452 | 135 | 4.07 / 647.71 | 6 | 72 |
7 | 8 | 0.00 | 212 | 14.88 | 361 | 1139 | 5.20 / 648.84 | 6 | 133 |
Average= | 7.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 33 | 14.88 | 503 | 247 | 0.25 / 638.72 | 6 | 37 |
2 | 7 | 2016.36 | 40 | 14.43 | 3077 | 1776 | 2.02 / 640.49 | 47 | 54 |
3 | 13 | 1931.96 | 20 | 14.42 | 2977 | 859 | 2.88 / 641.35 | 6 | 59 |
4 | 13 | 1412.40 | 20 | 14.47 | 2301 | 666 | 3.55 / 642.02 | 6 | 70 |
5 | 13 | 587.92 | 20 | 14.74 | 1180 | 348 | 3.90 / 642.37 | 6 | 75 |
6 | 13 | 36.80 | 20 | 14.95 | 430 | 129 | 4.02 / 642.50 | 6 | 70 |
7 | 8 | 0.24 | 210 | 14.89 | 366 | 1144 | 5.17 / 643.64 | 6 | 130 |
Average= | 7.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 33 | 14.87 | 526 | 258 | 0.26 / 633.57 | 6 | 40 |
2 | 7 | 2004.96 | 40 | 14.44 | 3048 | 1761 | 2.02 / 635.33 | 40 | 55 |
3 | 13 | 1912.84 | 20 | 14.44 | 2911 | 841 | 2.86 / 636.18 | 6 | 59 |
4 | 13 | 1380.44 | 20 | 14.49 | 2253 | 653 | 3.51 / 636.83 | 6 | 70 |
5 | 13 | 617.12 | 20 | 14.72 | 1225 | 361 | 3.87 / 637.19 | 6 | 79 |
6 | 13 | 44.32 | 20 | 14.94 | 438 | 131 | 4.00 / 637.32 | 6 | 71 |
7 | 8 | 0.16 | 212 | 14.89 | 365 | 1152 | 5.16 / 638.47 | 6 | 132 |
Average= | 7.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 33 | 14.85 | 515 | 252 | 0.25 / 628.41 | 6 | 42 |
2 | 7 | 2009.80 | 40 | 14.43 | 3062 | 1767 | 2.02 / 630.18 | 59 | 54 |
3 | 13 | 1932.16 | 20 | 14.42 | 2987 | 861 | 2.88 / 631.04 | 6 | 60 |
4 | 13 | 1309.00 | 20 | 14.51 | 2163 | 628 | 3.51 / 631.67 | 6 | 71 |
5 | 13 | 675.72 | 20 | 14.70 | 1316 | 387 | 3.90 / 632.05 | 6 | 79 |
6 | 13 | 31.12 | 20 | 14.95 | 416 | 124 | 4.02 / 632.18 | 6 | 73 |
7 | 8 | 0.08 | 208 | 14.89 | 367 | 1137 | 5.16 / 633.32 | 6 | 135 |
Average= | 7.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 33 | 14.87 | 517 | 254 | 0.25 / 623.22 | 6 | 40 |
2 | 7 | 2011.80 | 40 | 14.42 | 3068 | 1770 | 2.02 / 624.99 | 40 | 57 |
3 | 13 | 1922.84 | 20 | 14.42 | 2966 | 855 | 2.88 / 625.84 | 6 | 61 |
4 | 13 | 1382.96 | 20 | 14.48 | 2252 | 652 | 3.53 / 626.49 | 6 | 70 |
5 | 13 | 727.76 | 20 | 14.67 | 1372 | 403 | 3.93 / 626.90 | 6 | 79 |
6 | 13 | 38.72 | 20 | 14.93 | 423 | 126 | 4.06 / 627.02 | 6 | 81 |
7 | 8 | 0.20 | 206 | 14.87 | 371 | 1136 | 5.20 / 628.16 | 6 | 129 |
Average= | 7.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 33 | 14.87 | 510 | 250 | 0.25 / 618.08 | 6 | 40 |
2 | 7 | 2006.40 | 40 | 14.44 | 3063 | 1769 | 2.02 / 619.85 | 40 | 56 |
3 | 13 | 1910.64 | 20 | 14.43 | 2938 | 848 | 2.87 / 620.70 | 6 | 59 |
4 | 13 | 1470.16 | 20 | 14.47 | 2351 | 680 | 3.55 / 621.38 | 6 | 67 |
5 | 13 | 597.52 | 20 | 14.73 | 1191 | 351 | 3.90 / 621.73 | 6 | 77 |
6 | 13 | 36.76 | 20 | 14.95 | 403 | 120 | 4.02 / 621.85 | 6 | 74 |
7 | 8 | 0.20 | 206 | 14.89 | 363 | 1113 | 5.13 / 622.96 | 6 | 129 |
Average= | 7.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 33 | 14.87 | 500 | 245 | 0.25 / 613.04 | 6 | 40 |
2 | 7 | 2004.08 | 40 | 14.44 | 3036 | 1754 | 2.00 / 614.80 | 40 | 53 |
3 | 13 | 1908.16 | 20 | 14.44 | 2895 | 836 | 2.84 / 615.63 | 6 | 59 |
4 | 13 | 1258.16 | 20 | 14.52 | 2091 | 607 | 3.44 / 616.24 | 6 | 72 |
5 | 13 | 528.00 | 20 | 14.77 | 1089 | 322 | 3.76 / 616.56 | 6 | 72 |
6 | 13 | 44.64 | 20 | 14.94 | 434 | 130 | 3.89 / 616.69 | 6 | 69 |
7 | 8 | 0.04 | 210 | 14.88 | 365 | 1141 | 5.03 / 617.83 | 6 | 134 |
Average= | 8.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 33 | 14.87 | 502 | 246 | 0.25 / 607.79 | 6 | 41 |
2 | 7 | 2006.48 | 40 | 14.44 | 3039 | 1755 | 2.00 / 609.55 | 41 | 55 |
3 | 13 | 1923.36 | 20 | 14.43 | 2965 | 856 | 2.86 / 610.40 | 6 | 59 |
4 | 13 | 1616.04 | 20 | 14.42 | 2561 | 739 | 3.60 / 611.14 | 6 | 65 |
5 | 13 | 685.04 | 20 | 14.69 | 1313 | 386 | 3.98 / 611.53 | 6 | 75 |
6 | 13 | 29.72 | 20 | 14.94 | 410 | 123 | 4.10 / 611.65 | 6 | 70 |
7 | 8 | 0.08 | 212 | 14.88 | 364 | 1148 | 5.25 / 612.80 | 6 | 130 |
Average= | 8.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.84 | 33 | 14.86 | 534 | 262 | 0.26 / 602.69 | 6 | 41 |
2 | 7 | 2005.72 | 40 | 14.44 | 3075 | 1776 | 2.04 / 604.46 | 41 | 55 |
3 | 13 | 1923.00 | 20 | 14.43 | 2974 | 858 | 2.90 / 605.32 | 6 | 59 |
4 | 13 | 1378.68 | 20 | 14.49 | 2256 | 654 | 3.55 / 605.97 | 6 | 68 |
5 | 13 | 614.48 | 20 | 14.74 | 1215 | 358 | 3.91 / 606.33 | 6 | 73 |
6 | 13 | 19.20 | 20 | 14.96 | 376 | 112 | 4.02 / 606.45 | 6 | 68 |
7 | 8 | -0.04 | 206 | 14.89 | 358 | 1098 | 5.12 / 607.54 | 6 | 133 |
Average= | 8.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 33 | 14.87 | 514 | 252 | 0.25 / 597.49 | 6 | 45 |
2 | 7 | 2015.36 | 40 | 14.43 | 3081 | 1778 | 2.03 / 599.27 | 45 | 53 |
3 | 13 | 1920.04 | 20 | 14.43 | 2976 | 859 | 2.89 / 600.13 | 6 | 58 |
4 | 13 | 1487.64 | 20 | 14.45 | 2408 | 696 | 3.59 / 600.83 | 6 | 66 |
5 | 13 | 572.44 | 20 | 14.75 | 1148 | 339 | 3.92 / 601.17 | 6 | 72 |
6 | 13 | 56.52 | 20 | 14.94 | 440 | 131 | 4.06 / 601.30 | 6 | 69 |
7 | 8 | 0.20 | 208 | 14.89 | 364 | 1127 | 5.18 / 602.42 | 6 | 132 |
Average= | 8.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 33 | 14.86 | 516 | 253 | 0.25 / 592.29 | 6 | 45 |
2 | 7 | 2006.44 | 41 | 14.45 | 3051 | 1808 | 2.06 / 594.10 | 54 | 52 |
3 | 13 | 1926.60 | 20 | 14.43 | 2951 | 852 | 2.91 / 594.95 | 6 | 56 |
4 | 13 | 1387.80 | 20 | 14.49 | 2269 | 658 | 3.57 / 595.61 | 6 | 68 |
5 | 13 | 727.16 | 20 | 14.70 | 1375 | 404 | 3.97 / 596.01 | 6 | 72 |
6 | 8 | -0.08 | 231 | 14.90 | 358 | 1232 | 5.21 / 597.24 | 6 | 131 |
Average= | 8.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 32 | 14.86 | 501 | 238 | 0.24 / 587.08 | 6 | 45 |
2 | 7 | 2005.52 | 40 | 14.44 | 3055 | 1765 | 2.00 / 588.84 | 47 | 55 |
3 | 13 | 1915.48 | 20 | 14.44 | 2966 | 857 | 2.86 / 589.70 | 6 | 59 |
4 | 13 | 1397.80 | 20 | 14.49 | 2278 | 660 | 3.52 / 590.36 | 6 | 65 |
5 | 13 | 727.68 | 20 | 14.69 | 1357 | 399 | 3.92 / 590.76 | 6 | 70 |
6 | 13 | 34.08 | 20 | 14.95 | 420 | 126 | 4.04 / 590.88 | 6 | 67 |
7 | 8 | 0.20 | 212 | 14.89 | 365 | 1152 | 5.20 / 592.04 | 6 | 133 |
Average= | 8.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 33 | 14.86 | 511 | 251 | 0.25 / 581.82 | 6 | 46 |
2 | 7 | 2006.72 | 41 | 14.43 | 3066 | 1814 | 2.06 / 583.64 | 46 | 54 |
3 | 13 | 1917.20 | 20 | 14.43 | 2952 | 852 | 2.92 / 584.49 | 6 | 58 |
4 | 13 | 1338.44 | 20 | 14.50 | 2198 | 637 | 3.55 / 585.13 | 6 | 70 |
5 | 13 | 887.24 | 20 | 14.62 | 1594 | 466 | 4.02 / 585.59 | 6 | 74 |
6 | 13 | 8.12 | 20 | 14.96 | 358 | 107 | 4.13 / 585.70 | 6 | 68 |
7 | 8 | -0.20 | 212 | 14.89 | 361 | 1140 | 5.27 / 586.84 | 6 | 136 |
Average= | 8.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 33 | 14.87 | 513 | 252 | 0.25 / 576.81 | 6 | 45 |
2 | 7 | 2007.04 | 41 | 14.44 | 3048 | 1805 | 2.06 / 578.62 | 45 | 53 |
3 | 13 | 1912.96 | 20 | 14.43 | 2933 | 846 | 2.90 / 579.46 | 6 | 56 |
4 | 13 | 1276.96 | 20 | 14.52 | 2121 | 616 | 3.52 / 580.08 | 6 | 69 |
5 | 13 | 509.68 | 20 | 14.78 | 1061 | 314 | 3.83 / 580.39 | 6 | 70 |
6 | 8 | 0.08 | 229 | 14.90 | 346 | 1181 | 5.01 / 581.57 | 6 | 129 |
Average= | 8.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 32 | 14.86 | 523 | 249 | 0.25 / 571.75 | 6 | 44 |
2 | 7 | 2014.84 | 40 | 14.45 | 3074 | 1777 | 2.03 / 573.53 | 36 | 53 |
3 | 13 | 1927.00 | 20 | 14.44 | 2963 | 856 | 2.88 / 574.39 | 6 | 58 |
4 | 13 | 1296.24 | 20 | 14.53 | 2124 | 617 | 3.50 / 575.00 | 6 | 66 |
5 | 13 | 643.56 | 20 | 14.73 | 1243 | 366 | 3.86 / 575.37 | 6 | 71 |
6 | 8 | 0.16 | 231 | 14.90 | 346 | 1191 | 5.06 / 576.56 | 6 | 135 |
Average= | 8.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 32 | 14.87 | 500 | 238 | 0.24 / 566.62 | 6 | 47 |
2 | 7 | 2003.32 | 40 | 14.46 | 3055 | 1767 | 2.00 / 568.39 | 47 | 52 |
3 | 13 | 1909.12 | 20 | 14.45 | 2942 | 850 | 2.86 / 569.24 | 6 | 56 |
4 | 13 | 1280.72 | 20 | 14.53 | 2119 | 616 | 3.47 / 569.85 | 6 | 69 |
5 | 13 | 725.28 | 20 | 14.70 | 1387 | 408 | 3.88 / 570.26 | 6 | 70 |
6 | 8 | 0.00 | 233 | 14.89 | 358 | 1242 | 5.12 / 571.50 | 6 | 136 |
Average= | 8.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 32 | 14.85 | 526 | 250 | 0.25 / 561.48 | 6 | 47 |
2 | 7 | 2008.40 | 40 | 14.46 | 3046 | 1762 | 2.01 / 563.24 | 47 | 50 |
3 | 13 | 1910.84 | 20 | 14.45 | 2940 | 850 | 2.86 / 564.09 | 6 | 55 |
4 | 13 | 1474.76 | 20 | 14.48 | 2356 | 682 | 3.54 / 564.77 | 6 | 67 |
5 | 13 | 792.76 | 20 | 14.68 | 1454 | 427 | 3.97 / 565.20 | 6 | 70 |
6 | 8 | 0.44 | 229 | 14.90 | 348 | 1187 | 5.16 / 566.38 | 6 | 129 |
Average= | 8.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 32 | 14.86 | 510 | 243 | 0.24 / 556.34 | 6 | 46 |
2 | 7 | 2005.16 | 40 | 14.47 | 3018 | 1747 | 1.99 / 558.08 | 46 | 48 |
3 | 13 | 1915.04 | 20 | 14.45 | 2926 | 846 | 2.83 / 558.93 | 6 | 53 |
4 | 13 | 1379.12 | 20 | 14.51 | 2243 | 651 | 3.49 / 559.58 | 6 | 67 |
5 | 13 | 727.32 | 20 | 14.71 | 1352 | 398 | 3.88 / 559.98 | 6 | 69 |
6 | 8 | 0.12 | 231 | 14.89 | 363 | 1249 | 5.13 / 561.23 | 6 | 131 |
Average= | 8.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 32 | 14.87 | 513 | 244 | 0.24 / 551.21 | 6 | 47 |
2 | 7 | 2006.24 | 40 | 14.47 | 3022 | 1749 | 1.99 / 552.95 | 47 | 48 |
3 | 13 | 1912.76 | 20 | 14.45 | 2951 | 853 | 2.85 / 553.81 | 6 | 55 |
4 | 13 | 1370.80 | 20 | 14.51 | 2234 | 648 | 3.49 / 554.46 | 6 | 65 |
5 | 13 | 701.20 | 20 | 14.72 | 1319 | 388 | 3.88 / 554.84 | 6 | 69 |
6 | 13 | 61.84 | 20 | 14.95 | 424 | 127 | 4.01 / 554.97 | 6 | 65 |
7 | 8 | -0.04 | 214 | 14.90 | 352 | 1122 | 5.13 / 556.09 | 6 | 139 |
Average= | 8.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 33 | 14.86 | 495 | 243 | 0.24 / 546.11 | 6 | 48 |
2 | 3 | 964.36 | -1 | 15.33 | 11 | 0 | 0.00 / 546.11 | 6 | 48 |
3 | 7 | 2009.12 | 40 | 14.47 | 3043 | 1761 | 2.00 / 547.88 | 48 | 52 |
4 | 13 | 1928.32 | 20 | 14.46 | 2931 | 848 | 2.85 / 548.72 | 6 | 55 |
5 | 13 | 1308.12 | 20 | 14.53 | 2137 | 621 | 3.47 / 549.34 | 6 | 67 |
6 | 13 | 680.28 | 20 | 14.73 | 1287 | 379 | 3.85 / 549.72 | 6 | 70 |
7 | 8 | 0.04 | 229 | 14.90 | 363 | 1239 | 5.09 / 550.96 | 6 | 134 |
Average= | 8.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 33 | 14.87 | 515 | 253 | 0.25 / 540.95 | 6 | 47 |
2 | 7 | 2012.60 | 40 | 14.46 | 3058 | 1769 | 2.02 / 542.72 | 47 | 51 |
3 | 13 | 1920.76 | 20 | 14.46 | 2925 | 846 | 2.87 / 543.57 | 6 | 54 |
4 | 13 | 1274.72 | 20 | 14.54 | 2098 | 610 | 3.48 / 544.18 | 6 | 67 |
5 | 13 | 704.40 | 20 | 14.72 | 1332 | 392 | 3.87 / 544.57 | 6 | 69 |
6 | 13 | 60.44 | 20 | 14.95 | 428 | 128 | 4.00 / 544.70 | 6 | 64 |
7 | 13 | 33.28 | 20 | 14.94 | 406 | 121 | 4.12 / 544.82 | 6 | 67 |
8 | 8 | -0.12 | 191 | 14.89 | 354 | 1007 | 5.13 / 545.82 | 6 | 135 |
9 | 14 | -0.24 | 9 | 14.85 | 347 | 46 | 5.17 / 545.87 | 43 | 152 |
Average= | 8.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 33 | 14.87 | 517 | 254 | 0.25 / 535.76 | 6 | 46 |
2 | 7 | 2008.80 | 40 | 14.47 | 3031 | 1754 | 2.01 / 537.52 | 46 | 49 |
3 | 13 | 1916.40 | 20 | 14.46 | 2935 | 849 | 2.86 / 538.36 | 6 | 54 |
4 | 13 | 1495.08 | 20 | 14.48 | 2375 | 688 | 3.54 / 539.05 | 6 | 63 |
5 | 13 | 708.04 | 20 | 14.73 | 1323 | 390 | 3.93 / 539.44 | 6 | 68 |
6 | 13 | 73.52 | 20 | 14.95 | 439 | 131 | 4.07 / 539.57 | 6 | 63 |
7 | 8 | -0.08 | 214 | 14.90 | 353 | 1126 | 5.19 / 540.70 | 6 | 130 |
Average= | 8.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 33 | 14.88 | 496 | 244 | 0.24 / 530.71 | 6 | 47 |
2 | 7 | 2003.28 | 40 | 14.46 | 3050 | 1764 | 2.01 / 532.48 | 47 | 50 |
3 | 13 | 1814.84 | 20 | 14.46 | 2840 | 821 | 2.83 / 533.30 | 6 | 58 |
4 | 13 | 1304.20 | 20 | 14.53 | 2152 | 625 | 3.45 / 533.92 | 6 | 67 |
5 | 13 | 646.12 | 20 | 14.75 | 1242 | 366 | 3.82 / 534.29 | 6 | 68 |
6 | 8 | 0.52 | 231 | 14.91 | 354 | 1219 | 5.04 / 535.51 | 6 | 134 |
Average= | 8.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 33 | 14.87 | 518 | 254 | 0.25 / 525.64 | 6 | 45 |
2 | 7 | 2011.96 | 40 | 14.46 | 3061 | 1770 | 2.02 / 527.42 | 45 | 51 |
3 | 13 | 1919.12 | 20 | 14.45 | 2948 | 852 | 2.88 / 528.27 | 6 | 54 |
4 | 13 | 1295.88 | 20 | 14.54 | 2128 | 619 | 3.50 / 528.89 | 6 | 65 |
5 | 13 | 742.56 | 20 | 14.71 | 1375 | 405 | 3.90 / 529.29 | 6 | 68 |
6 | 8 | -0.24 | 233 | 14.91 | 339 | 1178 | 5.08 / 530.47 | 6 | 141 |
Average= | 8.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 33 | 14.86 | 529 | 259 | 0.26 / 520.45 | 6 | 45 |
2 | 7 | 2003.64 | 40 | 14.47 | 3036 | 1757 | 2.02 / 522.21 | 45 | 52 |
3 | 13 | 1909.20 | 20 | 14.47 | 2917 | 844 | 2.86 / 523.05 | 6 | 55 |
4 | 13 | 1476.80 | 20 | 14.49 | 2360 | 684 | 3.54 / 523.74 | 6 | 62 |
5 | 13 | 787.56 | 20 | 14.69 | 1440 | 423 | 3.97 / 524.16 | 6 | 71 |
6 | 13 | 17.64 | 20 | 14.96 | 383 | 115 | 4.08 / 524.27 | 6 | 63 |
7 | 8 | 0.32 | 212 | 14.91 | 353 | 1116 | 5.20 / 525.39 | 6 | 132 |
Average= | 8.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 33 | 14.89 | 506 | 249 | 0.25 / 515.38 | 6 | 45 |
2 | 7 | 2004.72 | 40 | 14.47 | 3031 | 1754 | 2.00 / 517.13 | 45 | 50 |
3 | 13 | 1805.88 | 20 | 14.48 | 2798 | 810 | 2.81 / 517.94 | 6 | 58 |
4 | 13 | 1293.28 | 20 | 14.54 | 2133 | 620 | 3.43 / 518.56 | 6 | 68 |
5 | 13 | 735.76 | 20 | 14.71 | 1374 | 404 | 3.84 / 518.97 | 6 | 68 |
6 | 13 | 70.60 | 20 | 14.94 | 440 | 131 | 3.97 / 519.10 | 6 | 63 |
7 | 8 | -0.20 | 208 | 14.90 | 353 | 1094 | 5.06 / 520.19 | 6 | 129 |
Average= | 8.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 32 | 14.90 | 497 | 237 | 0.24 / 510.33 | 6 | 44 |
2 | 7 | 2005.88 | 40 | 14.47 | 3048 | 1764 | 2.00 / 512.09 | 42 | 51 |
3 | 13 | 1925.96 | 20 | 14.46 | 2963 | 857 | 2.86 / 512.95 | 6 | 55 |
4 | 13 | 1291.64 | 20 | 14.54 | 2126 | 618 | 3.48 / 513.57 | 6 | 67 |
5 | 13 | 552.60 | 20 | 14.79 | 1112 | 329 | 3.81 / 513.90 | 6 | 65 |
6 | 13 | 60.08 | 20 | 14.96 | 432 | 129 | 3.93 / 514.02 | 6 | 64 |
7 | 8 | 0.44 | 212 | 14.92 | 349 | 1104 | 5.04 / 515.13 | 6 | 137 |
Average= | 9.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 32 | 14.88 | 512 | 244 | 0.24 / 505.21 | 6 | 43 |
2 | 7 | 2007.24 | 40 | 14.48 | 3059 | 1772 | 2.02 / 506.98 | 43 | 52 |
3 | 13 | 1920.68 | 20 | 14.46 | 2952 | 854 | 2.87 / 507.83 | 6 | 56 |
4 | 13 | 1297.96 | 20 | 14.53 | 2151 | 625 | 3.49 / 508.46 | 6 | 68 |
5 | 13 | 659.88 | 20 | 14.75 | 1266 | 373 | 3.87 / 508.83 | 6 | 70 |
6 | 13 | 107.12 | 20 | 14.94 | 502 | 150 | 4.02 / 508.98 | 6 | 65 |
7 | 8 | -0.32 | 214 | 14.91 | 347 | 1107 | 5.13 / 510.09 | 6 | 137 |
Average= | 9.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 33 | 14.88 | 506 | 248 | 0.25 / 500.08 | 6 | 42 |
2 | 7 | 2005.88 | 40 | 14.46 | 3054 | 1766 | 2.01 / 501.85 | 42 | 54 |
3 | 13 | 1918.64 | 20 | 14.45 | 2952 | 853 | 2.87 / 502.70 | 6 | 57 |
4 | 13 | 1259.72 | 20 | 14.55 | 2085 | 607 | 3.47 / 503.31 | 6 | 69 |
5 | 13 | 613.36 | 20 | 14.76 | 1202 | 355 | 3.83 / 503.67 | 6 | 71 |
6 | 13 | 51.36 | 20 | 14.96 | 415 | 124 | 3.95 / 503.79 | 6 | 65 |
7 | 13 | 35.56 | 20 | 14.96 | 394 | 118 | 4.07 / 503.91 | 6 | 68 |
8 | 8 | 0.60 | 191 | 14.91 | 355 | 1011 | 5.08 / 504.92 | 6 | 134 |
9 | 14 | 0.44 | 9 | 14.86 | 352 | 47 | 5.13 / 504.97 | 45 | 178 |
Average= | 9.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 33 | 14.88 | 504 | 247 | 0.25 / 494.92 | 6 | 42 |
2 | 7 | 2008.12 | 40 | 14.47 | 3062 | 1772 | 2.02 / 496.69 | 42 | 53 |
3 | 13 | 1920.36 | 20 | 14.46 | 2937 | 849 | 2.87 / 497.54 | 6 | 55 |
4 | 13 | 1403.36 | 20 | 14.51 | 2256 | 655 | 3.52 / 498.19 | 6 | 65 |
5 | 13 | 742.40 | 20 | 14.70 | 1385 | 407 | 3.93 / 498.60 | 6 | 74 |
6 | 13 | 37.00 | 20 | 14.97 | 390 | 117 | 4.05 / 498.72 | 6 | 64 |
7 | 8 | -0.16 | 212 | 14.91 | 354 | 1119 | 5.17 / 499.84 | 6 | 132 |
Average= | 9.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 33 | 14.88 | 506 | 248 | 0.25 / 489.84 | 6 | 44 |
2 | 7 | 2003.52 | 40 | 14.47 | 3051 | 1766 | 2.01 / 491.61 | 44 | 52 |
3 | 13 | 1815.00 | 20 | 14.48 | 2799 | 811 | 2.82 / 492.42 | 6 | 58 |
4 | 13 | 1299.36 | 20 | 14.54 | 2130 | 619 | 3.44 / 493.04 | 6 | 69 |
5 | 13 | 642.68 | 20 | 14.74 | 1245 | 367 | 3.81 / 493.40 | 6 | 71 |
6 | 13 | 47.44 | 20 | 14.96 | 423 | 127 | 3.94 / 493.53 | 6 | 65 |
7 | 8 | -0.16 | 214 | 14.91 | 357 | 1139 | 5.08 / 494.67 | 6 | 140 |
Average= | 9.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 32 | 14.90 | 505 | 241 | 0.24 / 484.69 | 6 | 39 |
2 | 7 | 2015.40 | 40 | 14.46 | 3075 | 1779 | 2.02 / 486.47 | 51 | 53 |
3 | 13 | 1917.96 | 20 | 14.46 | 2940 | 850 | 2.87 / 487.32 | 6 | 58 |
4 | 13 | 1330.36 | 20 | 14.53 | 2174 | 632 | 3.50 / 487.95 | 6 | 68 |
5 | 13 | 767.84 | 20 | 14.69 | 1415 | 416 | 3.92 / 488.37 | 6 | 72 |
6 | 13 | 39.24 | 20 | 14.97 | 392 | 117 | 4.03 / 488.49 | 6 | 66 |
7 | 8 | 0.36 | 210 | 14.91 | 353 | 1105 | 5.14 / 489.59 | 6 | 129 |
Average= | 9.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 33 | 14.91 | 493 | 243 | 0.24 / 479.57 | 6 | 39 |
2 | 7 | 2005.80 | 40 | 14.48 | 3029 | 1754 | 2.00 / 481.32 | 39 | 53 |
3 | 13 | 1921.72 | 20 | 14.46 | 2969 | 859 | 2.86 / 482.18 | 6 | 59 |
4 | 13 | 1387.40 | 20 | 14.51 | 2255 | 654 | 3.51 / 482.84 | 6 | 68 |
5 | 13 | 699.68 | 20 | 14.72 | 1332 | 392 | 3.90 / 483.23 | 6 | 75 |
6 | 8 | 1.48 | 233 | 14.92 | 352 | 1224 | 5.13 / 484.45 | 6 | 140 |
Average= | 9.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 33 | 14.91 | 490 | 241 | 0.24 / 474.38 | 6 | 38 |
2 | 7 | 2010.80 | 40 | 14.48 | 3048 | 1765 | 2.01 / 476.14 | 38 | 52 |
3 | 13 | 1926.64 | 20 | 14.47 | 2935 | 849 | 2.86 / 476.99 | 6 | 57 |
4 | 13 | 1502.96 | 20 | 14.48 | 2413 | 699 | 3.55 / 477.69 | 6 | 64 |
5 | 13 | 731.08 | 20 | 14.71 | 1376 | 405 | 3.96 / 478.09 | 6 | 73 |
6 | 13 | 39.72 | 20 | 14.98 | 411 | 123 | 4.08 / 478.22 | 6 | 65 |
7 | 8 | -0.20 | 210 | 14.92 | 354 | 1109 | 5.19 / 479.33 | 6 | 129 |
Average= | 9.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 33 | 14.91 | 495 | 244 | 0.24 / 469.25 | 6 | 33 |
2 | 7 | 2005.40 | 40 | 14.48 | 3043 | 1763 | 2.01 / 471.01 | 33 | 54 |
3 | 13 | 1917.80 | 20 | 14.48 | 2919 | 845 | 2.85 / 471.86 | 6 | 57 |
4 | 13 | 1387.52 | 20 | 14.53 | 2242 | 652 | 3.50 / 472.51 | 6 | 67 |
5 | 13 | 719.92 | 20 | 14.72 | 1368 | 403 | 3.91 / 472.91 | 6 | 74 |
6 | 13 | 43.80 | 20 | 14.98 | 419 | 126 | 4.03 / 473.04 | 6 | 66 |
7 | 8 | 0.00 | 212 | 14.93 | 347 | 1098 | 5.13 / 474.13 | 6 | 134 |
Average= | 9.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 33 | 14.92 | 494 | 243 | 0.24 / 464.11 | 6 | 26 |
2 | 7 | 2005.00 | 41 | 14.47 | 3058 | 1814 | 2.06 / 465.93 | 26 | 55 |
3 | 13 | 1909.40 | 20 | 14.46 | 2940 | 850 | 2.91 / 466.78 | 6 | 60 |
4 | 13 | 1356.64 | 20 | 14.52 | 2224 | 646 | 3.55 / 467.42 | 6 | 69 |
5 | 13 | 591.48 | 20 | 14.76 | 1198 | 354 | 3.91 / 467.78 | 6 | 73 |
6 | 13 | 31.00 | 20 | 14.98 | 407 | 122 | 4.03 / 467.90 | 6 | 66 |
7 | 8 | 0.00 | 210 | 14.92 | 353 | 1106 | 5.14 / 469.01 | 6 | 133 |
Average= | 9.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 33 | 14.91 | 500 | 246 | 0.25 / 459.10 | 6 | 31 |
2 | 7 | 2007.24 | 40 | 14.48 | 3050 | 1767 | 2.01 / 460.86 | 31 | 54 |
3 | 13 | 1919.60 | 20 | 14.47 | 2957 | 856 | 2.87 / 461.72 | 6 | 57 |
4 | 13 | 1284.84 | 20 | 14.56 | 2115 | 616 | 3.48 / 462.33 | 6 | 69 |
5 | 13 | 551.48 | 20 | 14.80 | 1118 | 331 | 3.82 / 462.67 | 6 | 72 |
6 | 13 | 22.84 | 20 | 14.99 | 375 | 112 | 3.93 / 462.78 | 6 | 64 |
7 | 8 | 0.28 | 210 | 14.94 | 348 | 1092 | 5.02 / 463.87 | 6 | 130 |
Average= | 9.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 33 | 14.92 | 498 | 245 | 0.25 / 453.93 | 6 | 33 |
2 | 7 | 2009.60 | 40 | 14.47 | 3095 | 1791 | 2.04 / 455.72 | 33 | 50 |
3 | 13 | 1914.60 | 20 | 14.47 | 2965 | 858 | 2.89 / 456.58 | 6 | 58 |
4 | 13 | 1399.92 | 20 | 14.51 | 2287 | 664 | 3.56 / 457.24 | 6 | 70 |
5 | 13 | 729.52 | 20 | 14.71 | 1381 | 406 | 3.96 / 457.65 | 6 | 74 |
6 | 13 | 35.88 | 20 | 14.98 | 394 | 118 | 4.08 / 457.77 | 6 | 66 |
7 | 8 | 0.00 | 210 | 14.92 | 346 | 1084 | 5.17 / 458.85 | 6 | 138 |
Average= | 9.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 33 | 14.92 | 509 | 251 | 0.25 / 448.74 | 6 | 37 |
2 | 7 | 2016.32 | 40 | 14.49 | 3045 | 1765 | 2.02 / 450.50 | 37 | 51 |
3 | 13 | 1918.80 | 20 | 14.48 | 2942 | 852 | 2.87 / 451.35 | 6 | 57 |
4 | 13 | 1473.24 | 20 | 14.51 | 2350 | 682 | 3.55 / 452.04 | 6 | 67 |
5 | 13 | 691.68 | 20 | 14.74 | 1324 | 390 | 3.94 / 452.43 | 6 | 74 |
6 | 13 | 35.16 | 20 | 15.00 | 394 | 118 | 4.06 / 452.54 | 6 | 65 |
7 | 8 | 0.08 | 212 | 14.94 | 360 | 1140 | 5.20 / 453.68 | 6 | 129 |
Average= | 10.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 33 | 14.92 | 510 | 251 | 0.25 / 443.59 | 6 | 34 |
2 | 7 | 2014.16 | 41 | 14.47 | 3045 | 1807 | 2.06 / 445.40 | 34 | 55 |
3 | 13 | 1921.80 | 20 | 14.47 | 2928 | 847 | 2.90 / 446.24 | 6 | 60 |
4 | 13 | 1372.24 | 20 | 14.53 | 2224 | 646 | 3.55 / 446.89 | 6 | 69 |
5 | 13 | 611.56 | 20 | 14.77 | 1199 | 354 | 3.91 / 447.24 | 6 | 76 |
6 | 13 | 37.56 | 20 | 15.00 | 395 | 118 | 4.02 / 447.36 | 6 | 72 |
7 | 8 | -0.04 | 210 | 14.94 | 358 | 1123 | 5.15 / 448.49 | 6 | 141 |
Average= | 10.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 33 | 14.91 | 496 | 244 | 0.24 / 438.38 | 6 | 36 |
2 | 7 | 2005.32 | 40 | 14.48 | 3026 | 1753 | 2.00 / 440.13 | 36 | 55 |
3 | 13 | 1917.40 | 20 | 14.47 | 2918 | 844 | 2.84 / 440.98 | 6 | 57 |
4 | 13 | 1493.32 | 20 | 14.50 | 2386 | 692 | 3.53 / 441.67 | 6 | 67 |
5 | 13 | 834.80 | 20 | 14.67 | 1520 | 446 | 3.98 / 442.11 | 6 | 78 |
6 | 13 | 34.96 | 20 | 14.99 | 404 | 121 | 4.10 / 442.24 | 6 | 72 |
7 | 8 | 0.16 | 208 | 14.94 | 355 | 1103 | 5.20 / 443.34 | 6 | 132 |
Average= | 10.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 33 | 14.93 | 504 | 248 | 0.25 / 433.26 | 6 | 32 |
2 | 7 | 2011.32 | 40 | 14.48 | 3056 | 1770 | 2.02 / 435.03 | 32 | 56 |
3 | 13 | 1920.32 | 20 | 14.47 | 2963 | 857 | 2.88 / 435.89 | 6 | 60 |
4 | 13 | 1265.28 | 20 | 14.56 | 2087 | 608 | 3.48 / 436.50 | 6 | 71 |
5 | 13 | 733.32 | 20 | 14.72 | 1387 | 408 | 3.89 / 436.91 | 6 | 77 |
6 | 13 | 37.88 | 20 | 14.99 | 404 | 121 | 4.01 / 437.03 | 6 | 72 |
7 | 8 | 0.04 | 210 | 14.94 | 353 | 1108 | 5.12 / 438.14 | 6 | 131 |
Average= | 10.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 33 | 14.92 | 502 | 247 | 0.25 / 428.16 | 6 | 37 |
2 | 7 | 2009.80 | 40 | 14.47 | 3069 | 1776 | 2.02 / 429.93 | 37 | 56 |
3 | 13 | 1924.76 | 20 | 14.47 | 2962 | 857 | 2.88 / 430.79 | 6 | 61 |
4 | 13 | 1391.40 | 20 | 14.53 | 2273 | 661 | 3.54 / 431.45 | 6 | 70 |
5 | 13 | 613.52 | 20 | 14.77 | 1219 | 360 | 3.90 / 431.81 | 6 | 78 |
6 | 13 | 38.04 | 20 | 14.99 | 402 | 121 | 4.02 / 431.93 | 6 | 74 |
7 | 8 | 0.12 | 208 | 14.94 | 349 | 1085 | 5.11 / 433.01 | 6 | 130 |
Average= | 10.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 33 | 14.92 | 491 | 242 | 0.24 / 423.03 | 6 | 39 |
2 | 7 | 2004.64 | 40 | 14.48 | 3076 | 1782 | 2.02 / 424.81 | 39 | 56 |
3 | 13 | 1909.68 | 20 | 14.46 | 2966 | 858 | 2.88 / 425.67 | 6 | 59 |
4 | 13 | 1268.56 | 20 | 14.56 | 2109 | 614 | 3.50 / 426.28 | 6 | 72 |
5 | 13 | 727.68 | 20 | 14.72 | 1374 | 405 | 3.90 / 426.68 | 6 | 78 |
6 | 13 | 37.04 | 20 | 14.99 | 399 | 120 | 4.02 / 426.80 | 6 | 74 |
7 | 8 | 0.04 | 210 | 14.94 | 352 | 1104 | 5.12 / 427.91 | 6 | 135 |
Average= | 10.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 33 | 14.92 | 505 | 249 | 0.25 / 417.86 | 6 | 40 |
2 | 7 | 2009.60 | 40 | 14.48 | 3048 | 1765 | 2.01 / 419.63 | 55 | 57 |
3 | 13 | 1919.12 | 20 | 14.48 | 2951 | 855 | 2.87 / 420.48 | 6 | 60 |
4 | 13 | 1376.84 | 20 | 14.53 | 2237 | 650 | 3.52 / 421.13 | 6 | 68 |
5 | 13 | 713.40 | 20 | 14.72 | 1373 | 404 | 3.92 / 421.54 | 6 | 77 |
6 | 13 | 42.00 | 20 | 14.99 | 425 | 127 | 4.05 / 421.66 | 6 | 72 |
7 | 8 | 0.16 | 212 | 14.94 | 354 | 1121 | 5.17 / 422.78 | 6 | 137 |
Average= | 10.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 33 | 14.93 | 513 | 253 | 0.25 / 412.87 | 6 | 36 |
2 | 7 | 2005.76 | 40 | 14.48 | 3033 | 1757 | 2.01 / 414.63 | 36 | 55 |
3 | 13 | 1914.20 | 20 | 14.48 | 2950 | 854 | 2.86 / 415.48 | 6 | 58 |
4 | 13 | 1181.40 | 20 | 14.59 | 1974 | 576 | 3.44 / 416.06 | 6 | 73 |
5 | 13 | 555.08 | 20 | 14.80 | 1126 | 333 | 3.77 / 416.39 | 6 | 75 |
6 | 13 | 48.72 | 20 | 14.98 | 430 | 129 | 3.90 / 416.52 | 6 | 71 |
7 | 8 | -0.08 | 206 | 14.94 | 355 | 1093 | 4.99 / 417.61 | 6 | 133 |
Average= | 10.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 33 | 14.92 | 514 | 253 | 0.25 / 407.71 | 6 | 35 |
2 | 7 | 2006.28 | 41 | 14.48 | 3040 | 1805 | 2.06 / 409.51 | 35 | 56 |
3 | 13 | 1918.28 | 20 | 14.48 | 2939 | 851 | 2.91 / 410.36 | 6 | 59 |
4 | 13 | 1384.00 | 20 | 14.54 | 2243 | 652 | 3.56 / 411.02 | 6 | 68 |
5 | 13 | 607.40 | 20 | 14.78 | 1210 | 358 | 3.92 / 411.37 | 6 | 76 |
6 | 13 | 19.20 | 20 | 15.00 | 392 | 118 | 4.04 / 411.49 | 6 | 71 |
7 | 8 | 0.12 | 210 | 14.95 | 359 | 1127 | 5.16 / 412.62 | 6 | 134 |
Average= | 11.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 33 | 14.93 | 512 | 252 | 0.25 / 402.64 | 6 | 42 |
2 | 7 | 2008.40 | 40 | 14.49 | 3027 | 1754 | 2.01 / 404.39 | 42 | 54 |
3 | 13 | 1923.76 | 20 | 14.49 | 2890 | 838 | 2.84 / 405.23 | 6 | 58 |
4 | 13 | 1302.96 | 20 | 14.56 | 2133 | 621 | 3.47 / 405.85 | 6 | 71 |
5 | 13 | 642.56 | 20 | 14.76 | 1255 | 370 | 3.84 / 406.22 | 6 | 79 |
6 | 13 | 19.88 | 20 | 15.00 | 377 | 113 | 3.95 / 406.33 | 6 | 73 |
7 | 8 | -0.08 | 210 | 14.94 | 357 | 1120 | 5.07 / 407.45 | 6 | 136 |
Average= | 11.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 32 | 14.93 | 520 | 248 | 0.25 / 397.37 | 6 | 42 |
2 | 7 | 2007.60 | 41 | 14.49 | 3050 | 1812 | 2.06 / 399.18 | 42 | 55 |
3 | 13 | 1916.92 | 20 | 14.49 | 2911 | 844 | 2.90 / 400.03 | 6 | 58 |
4 | 13 | 1608.68 | 20 | 14.48 | 2546 | 737 | 3.64 / 400.76 | 6 | 64 |
5 | 13 | 692.92 | 20 | 14.75 | 1324 | 391 | 4.03 / 401.15 | 6 | 78 |
6 | 13 | 15.28 | 20 | 15.02 | 365 | 110 | 4.14 / 401.26 | 6 | 72 |
7 | 8 | 0.04 | 208 | 14.95 | 361 | 1123 | 5.26 / 402.39 | 6 | 131 |
Average= | 11.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 32 | 14.92 | 525 | 251 | 0.25 / 392.15 | 6 | 48 |
2 | 7 | 2007.92 | 40 | 14.49 | 3070 | 1779 | 2.03 / 393.93 | 48 | 54 |
3 | 13 | 1925.16 | 20 | 14.49 | 2952 | 855 | 2.89 / 394.79 | 6 | 57 |
4 | 13 | 1476.44 | 20 | 14.52 | 2382 | 692 | 3.58 / 395.48 | 6 | 67 |
5 | 13 | 700.96 | 20 | 14.75 | 1341 | 396 | 3.97 / 395.87 | 6 | 77 |
6 | 13 | 33.32 | 20 | 15.00 | 412 | 124 | 4.10 / 396.00 | 6 | 70 |
7 | 8 | 0.16 | 210 | 14.95 | 358 | 1124 | 5.22 / 397.12 | 6 | 133 |
Average= | 11.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 32 | 14.93 | 517 | 247 | 0.25 / 386.99 | 6 | 50 |
2 | 7 | 2013.40 | 40 | 14.49 | 3106 | 1800 | 2.05 / 388.79 | 50 | 56 |
3 | 13 | 1929.12 | 20 | 14.48 | 3003 | 870 | 2.92 / 389.66 | 6 | 60 |
4 | 13 | 1287.32 | 20 | 14.57 | 2132 | 621 | 3.54 / 390.28 | 6 | 70 |
5 | 13 | 638.80 | 20 | 14.77 | 1251 | 370 | 3.91 / 390.65 | 6 | 77 |
6 | 13 | 20.04 | 20 | 15.01 | 393 | 118 | 4.03 / 390.77 | 6 | 72 |
7 | 8 | 0.40 | 208 | 14.95 | 363 | 1129 | 5.15 / 391.90 | 6 | 130 |
Average= | 11.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 32 | 14.93 | 512 | 245 | 0.24 / 381.81 | 6 | 51 |
2 | 7 | 2014.36 | 40 | 14.49 | 3090 | 1791 | 2.04 / 383.60 | 51 | 57 |
3 | 13 | 1916.64 | 20 | 14.49 | 2949 | 855 | 2.89 / 384.46 | 6 | 61 |
4 | 13 | 1390.64 | 20 | 14.55 | 2271 | 661 | 3.55 / 385.12 | 6 | 69 |
5 | 13 | 726.32 | 20 | 14.74 | 1384 | 408 | 3.96 / 385.53 | 6 | 78 |
6 | 13 | 33.16 | 20 | 15.01 | 410 | 123 | 4.08 / 385.65 | 6 | 77 |
7 | 8 | 0.04 | 203 | 14.95 | 362 | 1099 | 5.18 / 386.75 | 6 | 133 |
Average= | 12.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 32 | 14.93 | 511 | 244 | 0.24 / 376.71 | 6 | 54 |
2 | 7 | 2011.48 | 40 | 14.48 | 3094 | 1792 | 2.04 / 378.50 | 54 | 58 |
3 | 13 | 1922.64 | 20 | 14.48 | 2977 | 862 | 2.90 / 379.36 | 6 | 61 |
4 | 13 | 1359.48 | 20 | 14.55 | 2237 | 651 | 3.55 / 380.02 | 6 | 72 |
5 | 13 | 590.64 | 20 | 14.80 | 1171 | 347 | 3.90 / 380.36 | 6 | 78 |
6 | 8 | 0.00 | 220 | 14.95 | 366 | 1204 | 5.10 / 381.57 | 6 | 132 |
Average= | 12.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 33 | 14.91 | 525 | 258 | 0.26 / 371.66 | 6 | 56 |
2 | 7 | 2004.92 | 40 | 14.48 | 3077 | 1782 | 2.04 / 373.44 | 56 | 56 |
3 | 13 | 1915.88 | 20 | 14.48 | 2951 | 855 | 2.90 / 374.30 | 6 | 62 |
4 | 13 | 1266.60 | 20 | 14.58 | 2108 | 615 | 3.51 / 374.91 | 6 | 72 |
5 | 13 | 614.16 | 20 | 14.78 | 1221 | 361 | 3.87 / 375.27 | 6 | 81 |
6 | 8 | 0.04 | 223 | 14.96 | 358 | 1194 | 5.07 / 376.47 | 6 | 136 |
Average= | 12.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 33 | 14.91 | 527 | 259 | 0.26 / 366.71 | 6 | 52 |
2 | 7 | 2004.68 | 40 | 14.50 | 3025 | 1754 | 2.01 / 368.46 | 52 | 55 |
3 | 13 | 1913.40 | 20 | 14.50 | 2932 | 850 | 2.86 / 369.32 | 6 | 60 |
4 | 13 | 1179.24 | 20 | 14.61 | 1973 | 577 | 3.44 / 369.89 | 6 | 72 |
5 | 13 | 550.48 | 20 | 14.81 | 1136 | 336 | 3.78 / 370.23 | 6 | 80 |
6 | 8 | 0.36 | 216 | 14.96 | 363 | 1173 | 4.95 / 371.40 | 6 | 133 |
Average= | 12.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 33 | 14.91 | 523 | 257 | 0.26 / 361.48 | 6 | 53 |
2 | 7 | 2009.36 | 40 | 14.49 | 3063 | 1775 | 2.03 / 363.26 | 53 | 59 |
3 | 13 | 1936.36 | 20 | 14.48 | 2979 | 863 | 2.90 / 364.12 | 6 | 61 |
4 | 13 | 1421.40 | 20 | 14.54 | 2290 | 666 | 3.56 / 364.79 | 6 | 71 |
5 | 13 | 842.68 | 20 | 14.69 | 1522 | 447 | 4.01 / 365.24 | 6 | 79 |
6 | 8 | -0.12 | 225 | 14.96 | 361 | 1215 | 5.22 / 366.45 | 6 | 132 |
Average= | 13.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 33 | 14.93 | 509 | 251 | 0.25 / 356.38 | 6 | 50 |
2 | 7 | 2003.56 | 40 | 14.50 | 3038 | 1762 | 2.01 / 358.15 | 50 | 54 |
3 | 13 | 1812.76 | 20 | 14.51 | 2806 | 814 | 2.83 / 358.96 | 6 | 60 |
4 | 13 | 1398.12 | 20 | 14.55 | 2260 | 658 | 3.48 / 359.62 | 6 | 69 |
5 | 13 | 633.84 | 20 | 14.77 | 1258 | 372 | 3.86 / 359.99 | 6 | 78 |
6 | 8 | 0.12 | 225 | 14.95 | 368 | 1238 | 5.09 / 361.23 | 6 | 136 |
Average= | 13.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 33 | 14.93 | 524 | 258 | 0.26 / 351.21 | 6 | 49 |
2 | 7 | 2006.60 | 40 | 14.49 | 3068 | 1778 | 2.04 / 352.99 | 49 | 55 |
3 | 13 | 1921.80 | 20 | 14.49 | 2981 | 864 | 2.90 / 353.85 | 6 | 57 |
4 | 13 | 1382.08 | 20 | 14.56 | 2245 | 654 | 3.55 / 354.51 | 6 | 68 |
5 | 13 | 726.76 | 20 | 14.75 | 1375 | 406 | 3.96 / 354.91 | 6 | 77 |
6 | 8 | -0.08 | 227 | 14.96 | 359 | 1219 | 5.18 / 356.13 | 6 | 139 |
Average= | 13.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 32 | 14.93 | 514 | 246 | 0.25 / 345.96 | 6 | 47 |
2 | 7 | 2005.28 | 40 | 14.51 | 3047 | 1768 | 2.01 / 347.73 | 47 | 52 |
3 | 13 | 1913.72 | 20 | 14.50 | 2932 | 850 | 2.86 / 348.58 | 6 | 58 |
4 | 13 | 1374.60 | 20 | 14.57 | 2235 | 651 | 3.52 / 349.23 | 6 | 67 |
5 | 13 | 712.92 | 20 | 14.77 | 1348 | 398 | 3.91 / 349.63 | 6 | 76 |
6 | 13 | 72.80 | 20 | 15.00 | 466 | 140 | 4.05 / 349.77 | 6 | 70 |
7 | 13 | 17.28 | 20 | 15.01 | 391 | 117 | 4.17 / 349.89 | 6 | 71 |
8 | 8 | 0.20 | 188 | 14.96 | 357 | 1004 | 5.18 / 350.89 | 6 | 130 |
9 | 14 | -0.08 | 12 | 14.91 | 353 | 63 | 5.24 / 350.95 | 32 | 186 |
Average= | 14.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 32 | 14.94 | 523 | 250 | 0.25 / 340.69 | 6 | 49 |
2 | 7 | 2006.76 | 40 | 14.50 | 3051 | 1770 | 2.02 / 342.46 | 49 | 56 |
3 | 13 | 1922.68 | 20 | 14.50 | 2938 | 852 | 2.87 / 343.31 | 6 | 58 |
4 | 13 | 1291.48 | 20 | 14.58 | 2129 | 621 | 3.49 / 343.94 | 6 | 72 |
5 | 13 | 849.12 | 20 | 14.70 | 1547 | 455 | 3.95 / 344.39 | 6 | 78 |
6 | 13 | 70.52 | 20 | 15.00 | 467 | 140 | 4.09 / 344.53 | 6 | 71 |
7 | 13 | 21.04 | 20 | 15.01 | 393 | 118 | 4.21 / 344.65 | 6 | 73 |
8 | 8 | -0.24 | 188 | 14.96 | 357 | 1004 | 5.21 / 345.65 | 6 | 136 |
9 | 14 | -0.24 | 12 | 14.91 | 357 | 64 | 5.27 / 345.72 | 42 | 205 |
Average= | 14.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 32 | 14.94 | 521 | 249 | 0.25 / 335.62 | 6 | 48 |
2 | 7 | 2007.16 | 41 | 14.51 | 3040 | 1809 | 2.06 / 337.43 | 48 | 54 |
3 | 13 | 1812.28 | 20 | 14.52 | 2813 | 817 | 2.87 / 338.25 | 6 | 61 |
4 | 13 | 1282.32 | 20 | 14.59 | 2117 | 618 | 3.49 / 338.87 | 6 | 71 |
5 | 13 | 629.32 | 20 | 14.80 | 1227 | 363 | 3.86 / 339.23 | 6 | 72 |
6 | 8 | 0.08 | 227 | 14.97 | 357 | 1213 | 5.07 / 340.44 | 6 | 135 |
Average= | 14.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 32 | 14.94 | 526 | 251 | 0.25 / 330.47 | 6 | 48 |
2 | 7 | 2005.12 | 40 | 14.51 | 3067 | 1780 | 2.03 / 332.25 | 20 | 54 |
3 | 13 | 1924.28 | 20 | 14.52 | 2928 | 850 | 2.88 / 333.10 | 6 | 58 |
4 | 13 | 1364.84 | 20 | 14.58 | 2218 | 647 | 3.53 / 333.74 | 6 | 69 |
5 | 13 | 700.36 | 20 | 14.77 | 1343 | 397 | 3.93 / 334.14 | 6 | 76 |
6 | 13 | 27.36 | 20 | 15.03 | 387 | 116 | 4.04 / 334.26 | 6 | 73 |
7 | 8 | 0.32 | 208 | 14.97 | 359 | 1118 | 5.16 / 335.37 | 6 | 134 |
Average= | 15.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 32 | 14.93 | 524 | 250 | 0.25 / 325.41 | 6 | 49 |
2 | 7 | 2005.28 | 40 | 14.51 | 3044 | 1767 | 2.02 / 327.18 | 49 | 54 |
3 | 13 | 1815.24 | 20 | 14.53 | 2801 | 814 | 2.83 / 327.99 | 6 | 58 |
4 | 13 | 1289.88 | 20 | 14.60 | 2117 | 618 | 3.45 / 328.61 | 6 | 70 |
5 | 13 | 736.28 | 20 | 14.75 | 1391 | 410 | 3.86 / 329.02 | 6 | 76 |
6 | 8 | 0.00 | 227 | 14.98 | 351 | 1194 | 5.05 / 330.21 | 6 | 141 |
Average= | 15.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 32 | 14.94 | 527 | 252 | 0.25 / 320.29 | 6 | 47 |
2 | 7 | 2005.88 | 40 | 14.52 | 3065 | 1780 | 2.03 / 322.07 | 47 | 54 |
3 | 13 | 1913.64 | 20 | 14.51 | 2957 | 858 | 2.89 / 322.93 | 6 | 60 |
4 | 13 | 1282.24 | 20 | 14.60 | 2122 | 620 | 3.51 / 323.55 | 6 | 70 |
5 | 13 | 738.96 | 20 | 14.75 | 1408 | 415 | 3.93 / 323.96 | 6 | 76 |
6 | 8 | 0.32 | 225 | 14.98 | 356 | 1200 | 5.13 / 325.16 | 6 | 129 |
Average= | 16.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 33 | 14.96 | 525 | 259 | 0.26 / 314.96 | 6 | 47 |
2 | 7 | 2008.40 | 40 | 14.52 | 3043 | 1767 | 2.03 / 316.72 | 47 | 53 |
3 | 13 | 1816.76 | 20 | 14.54 | 2796 | 813 | 2.84 / 317.54 | 6 | 59 |
4 | 13 | 1510.44 | 20 | 14.54 | 2432 | 707 | 3.55 / 318.24 | 6 | 66 |
5 | 13 | 711.28 | 20 | 14.77 | 1376 | 406 | 3.95 / 318.65 | 6 | 75 |
6 | 13 | 154.00 | 20 | 14.99 | 594 | 178 | 4.13 / 318.83 | 6 | 70 |
7 | 13 | 14.60 | 20 | 15.03 | 393 | 118 | 4.25 / 318.95 | 6 | 72 |
8 | 8 | 0.04 | 191 | 14.97 | 365 | 1044 | 5.29 / 319.99 | 6 | 132 |
9 | 14 | -0.04 | 9 | 14.93 | 351 | 47 | 5.34 / 320.04 | 41 | 159 |
Average= | 16.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 33 | 14.98 | 516 | 255 | 0.26 / 309.50 | 6 | 46 |
2 | 7 | 2004.16 | 40 | 14.53 | 3059 | 1778 | 2.03 / 311.28 | 45 | 53 |
3 | 13 | 1910.80 | 20 | 14.53 | 2914 | 847 | 2.88 / 312.13 | 6 | 57 |
4 | 13 | 1397.28 | 20 | 14.58 | 2281 | 665 | 3.54 / 312.79 | 6 | 65 |
5 | 13 | 755.80 | 20 | 14.76 | 1437 | 424 | 3.97 / 313.22 | 6 | 75 |
6 | 13 | 111.28 | 20 | 15.01 | 531 | 159 | 4.13 / 313.37 | 6 | 69 |
7 | 13 | 62.80 | 20 | 15.02 | 462 | 139 | 4.27 / 313.51 | 6 | 69 |
8 | 13 | 17.36 | 20 | 15.03 | 395 | 119 | 4.39 / 313.63 | 6 | 73 |
9 | 8 | -0.28 | 167 | 14.97 | 361 | 902 | 5.29 / 314.53 | 6 | 133 |
10 | 14 | -0.28 | 33 | 14.93 | 328 | 162 | 5.45 / 314.70 | 34 | -99 |
Average= | 17.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 32 | 14.97 | 530 | 254 | 0.25 / 304.46 | 6 | 44 |
2 | 7 | 2011.80 | 40 | 14.54 | 3032 | 1763 | 2.02 / 306.22 | 58 | 53 |
3 | 13 | 1819.76 | 20 | 14.55 | 2797 | 814 | 2.83 / 307.03 | 6 | 61 |
4 | 13 | 1203.96 | 20 | 14.64 | 2005 | 587 | 3.42 / 307.62 | 6 | 69 |
5 | 13 | 767.00 | 20 | 14.76 | 1449 | 428 | 3.85 / 308.05 | 6 | 78 |
6 | 8 | 0.16 | 227 | 15.00 | 352 | 1199 | 5.04 / 309.25 | 6 | 131 |
Average= | 18.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 32 | 14.96 | 534 | 256 | 0.26 / 299.29 | 6 | 48 |
2 | 7 | 2020.32 | 40 | 14.51 | 3093 | 1795 | 2.05 / 301.08 | 48 | 56 |
3 | 13 | 1938.84 | 20 | 14.51 | 2994 | 869 | 2.92 / 301.95 | 6 | 60 |
4 | 13 | 1420.00 | 20 | 14.57 | 2318 | 675 | 3.60 / 302.63 | 6 | 71 |
5 | 13 | 541.36 | 20 | 14.86 | 1119 | 333 | 3.93 / 302.96 | 6 | 79 |
6 | 8 | 0.36 | 227 | 15.01 | 365 | 1244 | 5.17 / 304.20 | 6 | 136 |
Average= | 19.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 32 | 14.98 | 522 | 250 | 0.25 / 294.06 | 6 | 47 |
2 | 7 | 2003.32 | 40 | 14.53 | 3035 | 1764 | 2.01 / 295.82 | 47 | 56 |
3 | 13 | 1910.68 | 20 | 14.53 | 2921 | 849 | 2.86 / 296.67 | 6 | 61 |
4 | 13 | 1484.08 | 20 | 14.58 | 2340 | 682 | 3.55 / 297.35 | 6 | 66 |
5 | 13 | 605.80 | 20 | 14.83 | 1225 | 363 | 3.91 / 297.72 | 6 | 79 |
6 | 13 | 164.72 | 20 | 15.00 | 614 | 184 | 4.09 / 297.90 | 6 | 81 |
7 | 8 | 0.12 | 199 | 14.99 | 377 | 1125 | 5.22 / 299.02 | 6 | 129 |
8 | 14 | 0.08 | 1 | 14.97 | 370 | 6 | 5.22 / 299.03 | 20 | 110 |
Average= | 19.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 32 | 14.98 | 514 | 246 | 0.25 / 288.97 | 6 | 45 |
2 | 7 | 2012.88 | 41 | 14.52 | 3055 | 1819 | 2.07 / 290.79 | 48 | 56 |
3 | 13 | 1919.16 | 20 | 14.53 | 2920 | 849 | 2.91 / 291.64 | 6 | 61 |
4 | 13 | 1193.40 | 20 | 14.66 | 1987 | 583 | 3.50 / 292.22 | 6 | 72 |
5 | 13 | 558.36 | 20 | 14.85 | 1143 | 339 | 3.84 / 292.56 | 6 | 81 |
6 | 8 | 0.28 | 223 | 15.00 | 372 | 1244 | 5.08 / 293.81 | 6 | 133 |
Average= | 20.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 33 | 14.99 | 515 | 255 | 0.25 / 283.84 | 6 | 43 |
2 | 7 | 2009.20 | 40 | 14.53 | 3066 | 1782 | 2.04 / 285.62 | 43 | 57 |
3 | 13 | 1922.80 | 20 | 14.53 | 2936 | 853 | 2.89 / 286.48 | 6 | 58 |
4 | 13 | 1367.52 | 20 | 14.61 | 2226 | 650 | 3.54 / 287.13 | 6 | 69 |
5 | 13 | 500.72 | 20 | 14.88 | 1054 | 314 | 3.85 / 287.44 | 6 | 80 |
6 | 13 | 40.08 | 20 | 15.05 | 430 | 129 | 3.98 / 287.57 | 6 | 85 |
7 | 8 | -0.24 | 206 | 15.00 | 374 | 1156 | 5.14 / 288.73 | 6 | 141 |
Average= | 22.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 31 | 14.98 | 530 | 246 | 0.25 / 278.53 | 6 | 40 |
2 | 3 | 1049.88 | 1 | 14.99 | 1829 | 27 | 0.27 / 278.56 | 6 | 68 |
3 | 7 | 2007.28 | 41 | 14.53 | 3024 | 1801 | 2.08 / 280.36 | 68 | 55 |
4 | 13 | 1908.40 | 20 | 14.53 | 2925 | 850 | 2.93 / 281.21 | 6 | 58 |
5 | 13 | 1469.80 | 20 | 14.58 | 2363 | 689 | 3.61 / 281.90 | 6 | 69 |
6 | 13 | 781.44 | 20 | 14.77 | 1458 | 431 | 4.04 / 282.33 | 6 | 79 |
7 | 13 | 46.04 | 20 | 15.05 | 445 | 134 | 4.18 / 282.46 | 6 | 83 |
8 | 8 | 0.08 | 203 | 15.00 | 370 | 1127 | 5.31 / 283.59 | 6 | 137 |
Average= | 23.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 32 | 15.00 | 512 | 246 | 0.25 / 273.18 | 6 | 33 |
2 | 10 | 1013.08 | 3 | 14.94 | 1744 | 78 | 0.32 / 273.26 | 6 | 62 |
3 | 3 | 921.40 | -1 | 15.40 | 11 | 0 | 0.08 / 273.26 | 6 | 62 |
4 | 7 | 2005.12 | 41 | 14.53 | 3021 | 1800 | 2.12 / 275.06 | 62 | 55 |
5 | 13 | 1909.68 | 20 | 14.54 | 2902 | 844 | 2.97 / 275.90 | 6 | 58 |
6 | 13 | 1490.24 | 20 | 14.57 | 2392 | 697 | 3.66 / 276.60 | 6 | 70 |
7 | 13 | 707.76 | 20 | 14.80 | 1356 | 401 | 4.07 / 277.00 | 6 | 80 |
8 | 13 | 40.28 | 20 | 15.05 | 447 | 135 | 4.20 / 277.13 | 6 | 84 |
9 | 8 | 0.00 | 201 | 15.00 | 381 | 1149 | 5.35 / 278.28 | 6 | 130 |
Average= | 25.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 32 | 15.01 | 511 | 245 | 0.25 / 267.63 | 6 | 35 |
2 | 7 | 2009.12 | 40 | 14.52 | 3068 | 1782 | 2.03 / 269.41 | 35 | 57 |
3 | 13 | 1929.60 | 20 | 14.54 | 2934 | 853 | 2.88 / 270.26 | 6 | 61 |
4 | 13 | 1520.56 | 20 | 14.57 | 2425 | 707 | 3.59 / 270.97 | 6 | 68 |
5 | 13 | 908.60 | 20 | 14.74 | 1611 | 475 | 4.06 / 271.44 | 6 | 76 |
6 | 13 | 545.04 | 20 | 14.85 | 1122 | 333 | 4.40 / 271.78 | 6 | 78 |
7 | 8 | 0.04 | 210 | 15.01 | 367 | 1157 | 5.55 / 272.93 | 6 | 141 |
Average= | 27.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 32 | 15.02 | 510 | 245 | 0.25 / 262.41 | 6 | 35 |
2 | 7 | 2006.68 | 40 | 14.55 | 3022 | 1759 | 2.00 / 264.16 | 35 | 56 |
3 | 13 | 1915.80 | 20 | 14.54 | 2949 | 858 | 2.86 / 265.02 | 6 | 60 |
4 | 13 | 1381.60 | 20 | 14.61 | 2265 | 662 | 3.52 / 265.68 | 6 | 71 |
5 | 13 | 710.36 | 20 | 14.81 | 1354 | 401 | 3.92 / 266.09 | 6 | 81 |
6 | 13 | 140.00 | 20 | 15.04 | 549 | 165 | 4.09 / 266.25 | 6 | 79 |
7 | 8 | 0.12 | 208 | 15.02 | 362 | 1131 | 5.22 / 267.38 | 6 | 142 |
Average= | 29.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 32 | 15.01 | 511 | 245 | 0.25 / 257.18 | 6 | 38 |
2 | 3 | 1019.88 | 1 | 15.09 | 1778 | 27 | 0.27 / 257.21 | 6 | 38 |
3 | 7 | 2011.64 | 40 | 14.53 | 3075 | 1787 | 2.06 / 259.00 | 38 | 57 |
4 | 13 | 1818.92 | 20 | 14.57 | 2804 | 817 | 2.88 / 259.82 | 6 | 61 |
5 | 13 | 1392.48 | 20 | 14.61 | 2275 | 665 | 3.54 / 260.48 | 6 | 69 |
6 | 13 | 717.48 | 20 | 14.82 | 1374 | 407 | 3.95 / 260.89 | 6 | 81 |
7 | 13 | 40.16 | 20 | 15.08 | 425 | 128 | 4.08 / 261.02 | 6 | 78 |
8 | 8 | 0.04 | 206 | 15.03 | 370 | 1146 | 5.22 / 262.16 | 6 | 133 |
Average= | 32.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 32 | 15.02 | 503 | 242 | 0.24 / 252.01 | 6 | 41 |
2 | 7 | 2010.76 | 41 | 14.53 | 3052 | 1818 | 2.06 / 253.82 | 41 | 56 |
3 | 13 | 1912.12 | 20 | 14.54 | 2930 | 852 | 2.91 / 254.68 | 6 | 60 |
4 | 13 | 1235.48 | 20 | 14.68 | 2049 | 602 | 3.51 / 255.28 | 6 | 73 |
5 | 13 | 593.68 | 20 | 14.87 | 1187 | 353 | 3.87 / 255.63 | 6 | 83 |
6 | 13 | 41.84 | 20 | 15.07 | 440 | 133 | 4.00 / 255.76 | 6 | 78 |
7 | 8 | 0.00 | 206 | 15.02 | 380 | 1176 | 5.17 / 256.94 | 6 | 133 |
Average= | 36.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 32 | 15.02 | 511 | 246 | 0.25 / 246.96 | 6 | 38 |
2 | 7 | 2006.40 | 40 | 14.54 | 3046 | 1772 | 2.02 / 248.74 | 38 | 55 |
3 | 13 | 1915.88 | 20 | 14.54 | 2933 | 853 | 2.87 / 249.59 | 6 | 59 |
4 | 13 | 1189.20 | 20 | 14.68 | 2007 | 589 | 3.46 / 250.18 | 6 | 72 |
5 | 13 | 457.64 | 20 | 14.92 | 1019 | 304 | 3.76 / 250.48 | 6 | 82 |
6 | 13 | 65.24 | 20 | 15.07 | 473 | 143 | 3.91 / 250.62 | 6 | 81 |
7 | 8 | 0.16 | 206 | 15.03 | 368 | 1139 | 5.05 / 251.76 | 6 | 129 |
Average= | 41.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 32 | 15.03 | 506 | 243 | 0.24 / 241.82 | 6 | 42 |
2 | 7 | 2013.84 | 41 | 14.54 | 3033 | 1808 | 2.05 / 243.63 | 42 | 55 |
3 | 13 | 1922.76 | 20 | 14.55 | 2929 | 852 | 2.90 / 244.48 | 6 | 61 |
4 | 13 | 1172.36 | 20 | 14.70 | 1978 | 582 | 3.49 / 245.06 | 6 | 73 |
5 | 13 | 646.72 | 20 | 14.86 | 1258 | 374 | 3.86 / 245.44 | 6 | 81 |
6 | 13 | 41.48 | 20 | 15.09 | 418 | 126 | 3.99 / 245.56 | 6 | 84 |
7 | 8 | -0.12 | 206 | 15.03 | 373 | 1155 | 5.14 / 246.72 | 6 | 134 |
Average= | 49.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 32 | 15.02 | 512 | 246 | 0.25 / 236.65 | 6 | 43 |
2 | 7 | 2008.92 | 40 | 14.55 | 3050 | 1775 | 2.02 / 238.43 | 43 | 56 |
3 | 13 | 1910.60 | 20 | 14.55 | 2927 | 852 | 2.87 / 239.28 | 6 | 61 |
4 | 13 | 1460.24 | 20 | 14.62 | 2343 | 685 | 3.56 / 239.96 | 6 | 70 |
5 | 13 | 598.72 | 20 | 14.89 | 1202 | 358 | 3.92 / 240.32 | 6 | 82 |
6 | 13 | 18.28 | 20 | 15.10 | 401 | 121 | 4.04 / 240.44 | 6 | 85 |
7 | 8 | 0.12 | 208 | 15.05 | 363 | 1136 | 5.17 / 241.58 | 6 | 134 |
Average= | 60.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 32 | 15.02 | 520 | 250 | 0.25 / 231.37 | 6 | 45 |
2 | 7 | 2004.64 | 40 | 14.55 | 3040 | 1769 | 2.02 / 233.14 | 45 | 56 |
3 | 13 | 1921.28 | 20 | 14.56 | 2938 | 856 | 2.87 / 234.00 | 6 | 60 |
4 | 13 | 1397.52 | 20 | 14.64 | 2263 | 663 | 3.54 / 234.66 | 6 | 69 |
5 | 13 | 710.08 | 20 | 14.84 | 1362 | 404 | 3.94 / 235.06 | 6 | 82 |
6 | 13 | 34.92 | 20 | 15.10 | 412 | 124 | 4.07 / 235.19 | 6 | 79 |
7 | 8 | 0.12 | 225 | 15.04 | 360 | 1218 | 5.28 / 236.40 | 6 | 130 |
Average= | 78.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.80 | 32 | 15.01 | 531 | 255 | 0.26 / 226.24 | 6 | 50 |
2 | 7 | 2015.88 | 40 | 14.53 | 3090 | 1796 | 2.05 / 228.04 | 50 | 56 |
3 | 13 | 1922.52 | 20 | 14.55 | 2947 | 858 | 2.91 / 228.89 | 6 | 61 |
4 | 13 | 1090.92 | 20 | 14.74 | 1875 | 553 | 3.46 / 229.45 | 6 | 74 |
5 | 13 | 563.80 | 20 | 14.90 | 1163 | 347 | 3.81 / 229.79 | 6 | 83 |
6 | 13 | 13.60 | 20 | 15.11 | 393 | 119 | 3.93 / 229.91 | 6 | 78 |
7 | 8 | -0.08 | 225 | 15.04 | 357 | 1208 | 5.13 / 231.12 | 6 | 136 |
Average= | 115.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 32 | 15.02 | 522 | 251 | 0.25 / 220.90 | 6 | 49 |
2 | 7 | 2004.48 | 40 | 14.56 | 3038 | 1769 | 2.02 / 222.67 | 49 | 54 |
3 | 13 | 1907.24 | 20 | 14.57 | 2927 | 853 | 2.87 / 223.52 | 6 | 61 |
4 | 13 | 1366.84 | 20 | 14.66 | 2237 | 656 | 3.53 / 224.18 | 6 | 69 |
5 | 13 | 707.28 | 20 | 14.85 | 1367 | 406 | 3.94 / 224.58 | 6 | 81 |
6 | 13 | 130.68 | 20 | 15.06 | 563 | 170 | 4.10 / 224.75 | 6 | 78 |
7 | 8 | 0.24 | 227 | 15.04 | 361 | 1232 | 5.34 / 225.99 | 6 | 144 |
Average= | 225.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 32 | 15.03 | 516 | 248 | 0.25 / 215.74 | 6 | 50 |
2 | 7 | 2013.20 | 40 | 14.55 | 3061 | 1782 | 2.03 / 217.52 | 50 | 56 |
3 | 13 | 1921.60 | 20 | 14.57 | 2945 | 858 | 2.89 / 218.38 | 6 | 61 |
4 | 13 | 1375.32 | 20 | 14.66 | 2237 | 656 | 3.54 / 219.04 | 6 | 69 |
5 | 13 | 608.72 | 20 | 14.90 | 1225 | 365 | 3.91 / 219.40 | 6 | 81 |
6 | 13 | 36.72 | 20 | 15.11 | 433 | 131 | 4.04 / 219.53 | 6 | 77 |
7 | 8 | 0.12 | 203 | 15.06 | 365 | 1116 | 5.16 / 220.65 | 6 | 130 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 32 | 15.02 | 535 | 257 | 0.26 / 210.54 | 6 | 54 |
2 | 7 | 2007.00 | 40 | 14.56 | 3063 | 1784 | 2.04 / 212.32 | 11 | 58 |
3 | 13 | 1815.28 | 20 | 14.60 | 2803 | 818 | 2.86 / 213.14 | 6 | 61 |
4 | 13 | 1207.24 | 20 | 14.72 | 2011 | 592 | 3.45 / 213.74 | 6 | 74 |
5 | 13 | 671.80 | 20 | 14.88 | 1293 | 385 | 3.84 / 214.12 | 6 | 80 |
6 | 13 | 49.24 | 20 | 15.10 | 453 | 137 | 3.97 / 214.26 | 6 | 79 |
7 | 8 | 0.04 | 225 | 15.05 | 365 | 1236 | 5.21 / 215.49 | 6 | 136 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 32 | 15.04 | 529 | 255 | 0.25 / 205.15 | 6 | 53 |
2 | 7 | 2011.80 | 40 | 14.56 | 3067 | 1786 | 2.04 / 206.93 | 53 | 57 |
3 | 13 | 1912.88 | 20 | 14.58 | 2945 | 859 | 2.90 / 207.79 | 6 | 61 |
4 | 13 | 1455.16 | 20 | 14.65 | 2338 | 685 | 3.58 / 208.48 | 6 | 69 |
5 | 13 | 800.56 | 20 | 14.84 | 1469 | 436 | 4.02 / 208.91 | 6 | 81 |
6 | 13 | 46.76 | 20 | 15.11 | 448 | 135 | 4.16 / 209.05 | 6 | 80 |
7 | 8 | 0.40 | 225 | 15.06 | 365 | 1237 | 5.39 / 210.28 | 6 | 136 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 32 | 15.03 | 531 | 255 | 0.26 / 199.83 | 6 | 51 |
2 | 7 | 2004.56 | 40 | 14.57 | 3019 | 1759 | 2.01 / 201.59 | 51 | 53 |
3 | 13 | 1906.88 | 20 | 14.57 | 2942 | 857 | 2.87 / 202.45 | 6 | 60 |
4 | 13 | 1476.92 | 20 | 14.64 | 2394 | 701 | 3.57 / 203.15 | 6 | 68 |
5 | 13 | 686.52 | 20 | 14.88 | 1327 | 395 | 3.97 / 203.54 | 6 | 81 |
6 | 13 | 58.44 | 20 | 15.11 | 454 | 137 | 4.11 / 203.68 | 6 | 71 |
7 | 8 | -0.08 | 227 | 15.07 | 354 | 1211 | 5.32 / 204.89 | 6 | 136 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 32 | 15.04 | 531 | 256 | 0.26 / 194.52 | 6 | 54 |
2 | 7 | 2003.76 | 41 | 14.56 | 3039 | 1814 | 2.07 / 196.34 | 54 | 56 |
3 | 13 | 1907.60 | 20 | 14.58 | 2923 | 852 | 2.92 / 197.19 | 6 | 59 |
4 | 13 | 1472.88 | 20 | 14.66 | 2334 | 684 | 3.61 / 197.87 | 6 | 69 |
5 | 13 | 493.48 | 20 | 14.96 | 1058 | 317 | 3.92 / 198.19 | 6 | 82 |
6 | 13 | 36.52 | 20 | 15.12 | 435 | 132 | 4.05 / 198.32 | 6 | 78 |
7 | 8 | -0.08 | 225 | 15.06 | 370 | 1254 | 5.31 / 199.57 | 6 | 131 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 32 | 15.05 | 533 | 257 | 0.26 / 189.27 | 6 | 56 |
2 | 7 | 2005.00 | 40 | 14.56 | 3053 | 1778 | 2.03 / 191.05 | 56 | 58 |
3 | 13 | 1911.48 | 20 | 14.57 | 2943 | 858 | 2.89 / 191.91 | 6 | 62 |
4 | 13 | 1200.04 | 20 | 14.73 | 2010 | 592 | 3.48 / 192.50 | 6 | 74 |
5 | 13 | 774.32 | 20 | 14.85 | 1440 | 428 | 3.91 / 192.93 | 6 | 81 |
6 | 8 | 0.00 | 244 | 15.08 | 364 | 1339 | 5.25 / 194.27 | 6 | 132 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 32 | 15.06 | 534 | 257 | 0.26 / 183.99 | 6 | 49 |
2 | 7 | 2015.32 | 40 | 14.56 | 3074 | 1790 | 2.05 / 185.78 | 49 | 55 |
3 | 13 | 1926.40 | 20 | 14.57 | 2979 | 868 | 2.92 / 186.65 | 6 | 59 |
4 | 13 | 1495.20 | 20 | 14.64 | 2408 | 705 | 3.62 / 187.35 | 6 | 68 |
5 | 13 | 669.04 | 20 | 14.90 | 1309 | 390 | 4.01 / 187.74 | 6 | 79 |
6 | 8 | 0.24 | 229 | 15.09 | 368 | 1272 | 5.28 / 189.02 | 6 | 131 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 32 | 15.06 | 529 | 255 | 0.25 / 178.81 | 6 | 56 |
2 | 7 | 2006.88 | 40 | 14.57 | 3038 | 1771 | 2.03 / 180.58 | 20 | 56 |
3 | 13 | 1912.88 | 20 | 14.58 | 2939 | 857 | 2.88 / 181.44 | 6 | 61 |
4 | 13 | 1370.04 | 20 | 14.69 | 2232 | 656 | 3.54 / 182.09 | 6 | 71 |
5 | 13 | 576.28 | 20 | 14.94 | 1171 | 350 | 3.89 / 182.44 | 6 | 83 |
6 | 8 | -0.04 | 227 | 15.09 | 376 | 1288 | 5.18 / 183.73 | 6 | 136 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.72 | 32 | 15.05 | 544 | 262 | 0.26 / 173.70 | 6 | 60 |
2 | 7 | 2003.80 | 40 | 14.57 | 3069 | 1789 | 2.05 / 175.49 | 11 | 59 |
3 | 13 | 1911.04 | 20 | 14.59 | 2952 | 861 | 2.91 / 176.35 | 6 | 62 |
4 | 13 | 1249.00 | 20 | 14.74 | 2075 | 612 | 3.52 / 176.97 | 6 | 72 |
5 | 13 | 511.56 | 20 | 14.98 | 1080 | 324 | 3.85 / 177.29 | 6 | 82 |
6 | 8 | 0.16 | 225 | 15.10 | 373 | 1267 | 5.11 / 178.56 | 6 | 130 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 32 | 15.06 | 530 | 255 | 0.26 / 168.33 | 6 | 58 |
2 | 7 | 2014.76 | 40 | 14.58 | 3062 | 1786 | 2.04 / 170.12 | 58 | 56 |
3 | 13 | 1922.04 | 20 | 14.59 | 2962 | 864 | 2.91 / 170.98 | 6 | 62 |
4 | 13 | 1381.52 | 20 | 14.70 | 2248 | 661 | 3.57 / 171.64 | 6 | 71 |
5 | 13 | 714.40 | 20 | 14.90 | 1352 | 403 | 3.97 / 172.04 | 6 | 81 |
6 | 13 | 18.28 | 20 | 15.16 | 398 | 121 | 4.09 / 172.17 | 6 | 82 |
7 | 8 | -0.08 | 225 | 15.09 | 376 | 1277 | 5.37 / 173.44 | 6 | 138 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 32 | 15.08 | 517 | 249 | 0.25 / 162.88 | 6 | 55 |
2 | 7 | 2006.60 | 40 | 14.57 | 3075 | 1792 | 2.04 / 164.68 | 55 | 57 |
3 | 13 | 1909.32 | 20 | 14.59 | 2956 | 863 | 2.90 / 165.54 | 6 | 61 |
4 | 13 | 1462.68 | 20 | 14.67 | 2369 | 695 | 3.60 / 166.23 | 6 | 69 |
5 | 13 | 885.56 | 20 | 14.84 | 1592 | 473 | 4.07 / 166.71 | 6 | 79 |
6 | 13 | 80.92 | 20 | 15.13 | 492 | 149 | 4.22 / 166.85 | 6 | 73 |
7 | 8 | 0.40 | 218 | 15.10 | 371 | 1221 | 5.44 / 168.08 | 6 | 144 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 32 | 15.07 | 530 | 256 | 0.26 / 157.63 | 6 | 55 |
2 | 7 | 2003.80 | 40 | 14.57 | 3097 | 1805 | 2.06 / 159.44 | 55 | 56 |
3 | 13 | 1807.56 | 20 | 14.61 | 2840 | 830 | 2.89 / 160.27 | 6 | 63 |
4 | 13 | 1397.40 | 20 | 14.69 | 2289 | 673 | 3.56 / 160.94 | 6 | 71 |
5 | 13 | 633.48 | 20 | 14.93 | 1269 | 379 | 3.94 / 161.32 | 6 | 81 |
6 | 13 | 17.64 | 20 | 15.16 | 407 | 123 | 4.07 / 161.44 | 6 | 81 |
7 | 8 | -0.20 | 212 | 15.10 | 372 | 1191 | 5.26 / 162.63 | 6 | 147 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 32 | 15.08 | 528 | 255 | 0.25 / 152.33 | 6 | 56 |
2 | 7 | 2010.36 | 41 | 14.56 | 3123 | 1864 | 2.12 / 154.20 | 56 | 56 |
3 | 13 | 1819.08 | 20 | 14.61 | 2869 | 838 | 2.96 / 155.04 | 6 | 63 |
4 | 13 | 1289.64 | 20 | 14.73 | 2164 | 638 | 3.59 / 155.67 | 6 | 71 |
5 | 13 | 603.16 | 20 | 14.94 | 1247 | 373 | 3.97 / 156.05 | 6 | 83 |
6 | 13 | 68.28 | 20 | 15.14 | 489 | 148 | 4.12 / 156.19 | 6 | 77 |
7 | 8 | 0.00 | 208 | 15.10 | 377 | 1184 | 5.30 / 157.38 | 6 | 134 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 32 | 15.08 | 533 | 257 | 0.26 / 147.06 | 6 | 55 |
2 | 7 | 2004.04 | 40 | 14.58 | 3076 | 1794 | 2.05 / 148.85 | 28 | 57 |
3 | 13 | 1908.04 | 20 | 14.60 | 2954 | 863 | 2.91 / 149.71 | 6 | 61 |
4 | 13 | 1469.28 | 20 | 14.68 | 2382 | 699 | 3.61 / 150.41 | 6 | 67 |
5 | 13 | 602.68 | 20 | 14.95 | 1229 | 367 | 3.98 / 150.78 | 6 | 84 |
6 | 8 | -0.04 | 226 | 15.12 | 380 | 1299 | 5.28 / 152.08 | 6 | 145 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 31 | 15.10 | 526 | 246 | 0.25 / 141.81 | 6 | 50 |
2 | 7 | 2002.88 | 40 | 14.58 | 3048 | 1778 | 2.02 / 143.59 | 50 | 56 |
3 | 13 | 1810.40 | 20 | 14.62 | 2816 | 823 | 2.85 / 144.42 | 6 | 63 |
4 | 13 | 1387.12 | 20 | 14.71 | 2254 | 663 | 3.51 / 145.08 | 6 | 70 |
5 | 13 | 677.72 | 20 | 14.93 | 1318 | 394 | 3.90 / 145.47 | 6 | 83 |
6 | 13 | 52.12 | 20 | 15.15 | 464 | 141 | 4.04 / 145.61 | 6 | 79 |
7 | 8 | 0.04 | 206 | 15.11 | 381 | 1186 | 5.23 / 146.80 | 6 | 130 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 31 | 15.10 | 513 | 240 | 0.24 / 136.63 | 6 | 51 |
2 | 7 | 2012.28 | 40 | 14.58 | 3100 | 1808 | 2.05 / 138.44 | 51 | 56 |
3 | 13 | 1926.40 | 20 | 14.60 | 2996 | 875 | 2.92 / 139.32 | 6 | 61 |
4 | 13 | 1289.28 | 20 | 14.75 | 2131 | 629 | 3.55 / 139.94 | 6 | 72 |
5 | 13 | 668.52 | 20 | 14.94 | 1302 | 389 | 3.94 / 140.33 | 6 | 83 |
6 | 8 | 0.16 | 220 | 15.13 | 371 | 1235 | 5.18 / 141.57 | 6 | 130 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 32 | 15.10 | 531 | 257 | 0.26 / 131.54 | 6 | 50 |
2 | 7 | 2006.60 | 40 | 14.58 | 3086 | 1800 | 2.06 / 133.34 | 50 | 56 |
3 | 13 | 1925.56 | 20 | 14.61 | 2948 | 861 | 2.92 / 134.20 | 6 | 59 |
4 | 13 | 1171.04 | 20 | 14.79 | 1974 | 584 | 3.50 / 134.79 | 6 | 75 |
5 | 13 | 540.68 | 20 | 14.99 | 1132 | 339 | 3.84 / 135.13 | 6 | 82 |
6 | 13 | 10.48 | 20 | 15.19 | 392 | 119 | 3.96 / 135.25 | 6 | 82 |
7 | 8 | 0.32 | 204 | 15.12 | 372 | 1147 | 5.11 / 136.39 | 6 | 143 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 32 | 15.11 | 517 | 250 | 0.25 / 126.38 | 6 | 48 |
2 | 7 | 2004.08 | 40 | 14.59 | 3066 | 1789 | 2.04 / 128.17 | 48 | 56 |
3 | 13 | 1811.12 | 20 | 14.64 | 2823 | 827 | 2.87 / 129.00 | 6 | 62 |
4 | 13 | 1295.64 | 20 | 14.75 | 2138 | 631 | 3.50 / 129.63 | 6 | 71 |
5 | 13 | 633.16 | 20 | 14.96 | 1246 | 373 | 3.87 / 130.00 | 6 | 81 |
6 | 13 | 88.80 | 20 | 15.16 | 484 | 147 | 4.02 / 130.15 | 6 | 82 |
7 | 8 | -0.20 | 203 | 15.13 | 370 | 1136 | 5.15 / 131.29 | 6 | 131 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 31 | 15.11 | 533 | 250 | 0.25 / 121.12 | 6 | 50 |
2 | 7 | 2005.48 | 40 | 14.58 | 3103 | 1810 | 2.06 / 122.93 | 50 | 56 |
3 | 13 | 1912.32 | 20 | 14.61 | 2967 | 867 | 2.93 / 123.80 | 6 | 60 |
4 | 13 | 1474.08 | 20 | 14.69 | 2401 | 705 | 3.63 / 124.50 | 6 | 69 |
5 | 13 | 606.04 | 20 | 14.97 | 1222 | 366 | 4.00 / 124.87 | 6 | 80 |
6 | 13 | 43.04 | 20 | 15.18 | 441 | 134 | 4.13 / 125.00 | 6 | 80 |
7 | 8 | 0.04 | 203 | 15.13 | 368 | 1130 | 5.26 / 126.13 | 6 | 132 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 31 | 15.11 | 528 | 247 | 0.25 / 115.96 | 6 | 45 |
2 | 7 | 2008.88 | 41 | 14.58 | 3104 | 1856 | 2.10 / 117.82 | 27 | 58 |
3 | 13 | 1803.80 | 20 | 14.64 | 2823 | 827 | 2.93 / 118.65 | 6 | 63 |
4 | 13 | 1267.84 | 20 | 14.76 | 2111 | 623 | 3.55 / 119.27 | 6 | 74 |
5 | 13 | 516.16 | 20 | 15.01 | 1099 | 330 | 3.88 / 119.60 | 6 | 83 |
6 | 13 | 42.40 | 20 | 15.18 | 440 | 134 | 4.02 / 119.73 | 6 | 83 |
7 | 8 | -0.12 | 202 | 15.14 | 372 | 1138 | 5.15 / 120.87 | 6 | 142 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 32 | 15.12 | 514 | 249 | 0.25 / 110.75 | 6 | 46 |
2 | 7 | 2005.04 | 40 | 14.59 | 3067 | 1790 | 2.04 / 112.54 | 46 | 56 |
3 | 13 | 1915.00 | 20 | 14.61 | 2962 | 865 | 2.90 / 113.41 | 6 | 59 |
4 | 13 | 1280.24 | 20 | 14.77 | 2130 | 629 | 3.53 / 114.03 | 6 | 72 |
5 | 13 | 710.48 | 20 | 14.93 | 1373 | 410 | 3.94 / 114.44 | 6 | 80 |
6 | 13 | 31.52 | 20 | 15.19 | 427 | 130 | 4.07 / 114.57 | 6 | 83 |
7 | 8 | -0.08 | 203 | 15.14 | 372 | 1143 | 5.22 / 115.72 | 6 | 135 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 31 | 15.14 | 515 | 242 | 0.24 / 105.53 | 6 | 44 |
2 | 7 | 2003.12 | 40 | 14.60 | 3079 | 1798 | 2.04 / 107.33 | 44 | 56 |
3 | 13 | 1907.68 | 20 | 14.61 | 2973 | 869 | 2.91 / 108.20 | 6 | 62 |
4 | 13 | 1273.00 | 20 | 14.77 | 2104 | 622 | 3.53 / 108.82 | 6 | 75 |
5 | 13 | 715.16 | 20 | 14.94 | 1361 | 407 | 3.94 / 109.23 | 6 | 79 |
6 | 13 | 64.64 | 20 | 15.19 | 470 | 143 | 4.08 / 109.37 | 6 | 76 |
7 | 8 | 0.16 | 202 | 15.15 | 369 | 1129 | 5.21 / 110.50 | 6 | 131 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 31 | 15.14 | 513 | 241 | 0.24 / 100.46 | 6 | 41 |
2 | 7 | 2004.76 | 40 | 14.60 | 3077 | 1797 | 2.04 / 102.26 | 41 | 56 |
3 | 13 | 1906.20 | 20 | 14.63 | 2961 | 866 | 2.90 / 103.12 | 6 | 62 |
4 | 13 | 1223.08 | 20 | 14.79 | 2046 | 605 | 3.51 / 103.73 | 6 | 75 |
5 | 13 | 595.68 | 20 | 14.99 | 1196 | 359 | 3.87 / 104.09 | 6 | 83 |
6 | 13 | 36.56 | 20 | 15.21 | 399 | 121 | 3.99 / 104.21 | 6 | 75 |
7 | 8 | 0.08 | 201 | 15.16 | 356 | 1085 | 5.07 / 105.29 | 6 | 132 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 31 | 15.15 | 511 | 240 | 0.24 / 95.31 | 6 | 36 |
2 | 7 | 2011.64 | 40 | 14.62 | 3043 | 1780 | 2.02 / 97.09 | 36 | 56 |
3 | 13 | 1925.40 | 20 | 14.63 | 2956 | 865 | 2.88 / 97.96 | 6 | 58 |
4 | 13 | 1385.32 | 20 | 14.75 | 2251 | 664 | 3.55 / 98.62 | 6 | 71 |
5 | 13 | 605.68 | 20 | 14.99 | 1213 | 364 | 3.91 / 98.98 | 6 | 78 |
6 | 8 | 0.16 | 225 | 15.16 | 362 | 1235 | 5.15 / 100.22 | 6 | 140 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 31 | 15.15 | 505 | 237 | 0.24 / 90.55 | 6 | 37 |
2 | 7 | 1752.76 | 40 | 14.71 | 2708 | 1593 | 1.83 / 92.14 | 37 | 59 |
3 | 13 | 1665.72 | 20 | 14.72 | 2635 | 776 | 2.61 / 92.92 | 6 | 66 |
4 | 13 | 1154.80 | 20 | 14.83 | 1960 | 581 | 3.19 / 93.50 | 6 | 75 |
5 | 13 | 499.52 | 20 | 15.05 | 1075 | 324 | 3.51 / 93.82 | 6 | 77 |
6 | 13 | 35.40 | 20 | 15.22 | 422 | 128 | 3.64 / 93.95 | 6 | 75 |
7 | 8 | 0.16 | 203 | 15.17 | 364 | 1121 | 4.76 / 95.07 | 6 | 139 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 31 | 15.15 | 504 | 237 | 0.24 / 85.38 | 6 | 36 |
2 | 7 | 2014.28 | 40 | 14.61 | 3093 | 1808 | 2.04 / 87.19 | 36 | 55 |
3 | 13 | 1923.08 | 20 | 14.64 | 2957 | 866 | 2.91 / 88.06 | 6 | 59 |
4 | 13 | 1268.88 | 20 | 14.79 | 2099 | 621 | 3.53 / 88.68 | 6 | 72 |
5 | 13 | 617.84 | 20 | 15.00 | 1218 | 365 | 3.90 / 89.04 | 6 | 77 |
6 | 13 | 41.12 | 20 | 15.21 | 428 | 130 | 4.03 / 89.17 | 6 | 71 |
7 | 8 | 0.20 | 206 | 15.17 | 364 | 1138 | 5.16 / 90.31 | 6 | 131 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 31 | 15.16 | 497 | 234 | 0.23 / 80.37 | 6 | 34 |
2 | 7 | 2010.20 | 40 | 14.62 | 3061 | 1790 | 2.02 / 82.16 | 34 | 55 |
3 | 13 | 1715.48 | 20 | 14.71 | 2666 | 784 | 2.81 / 82.95 | 6 | 63 |
4 | 13 | 1202.44 | 20 | 14.81 | 2013 | 596 | 3.40 / 83.54 | 6 | 73 |
5 | 13 | 554.52 | 20 | 15.02 | 1135 | 341 | 3.75 / 83.88 | 6 | 79 |
6 | 13 | 45.16 | 20 | 15.22 | 430 | 131 | 3.88 / 84.02 | 6 | 74 |
7 | 8 | -0.08 | 206 | 15.17 | 362 | 1131 | 5.01 / 85.15 | 6 | 136 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 31 | 15.16 | 507 | 238 | 0.24 / 75.05 | 6 | 32 |
2 | 7 | 2005.20 | 40 | 14.63 | 3073 | 1798 | 2.04 / 76.84 | 32 | 56 |
3 | 13 | 1915.12 | 20 | 14.65 | 2965 | 869 | 2.91 / 77.71 | 6 | 61 |
4 | 13 | 1481.08 | 20 | 14.73 | 2371 | 698 | 3.60 / 78.41 | 6 | 67 |
5 | 13 | 782.08 | 20 | 14.93 | 1473 | 440 | 4.04 / 78.85 | 6 | 79 |
6 | 13 | 47.28 | 20 | 15.22 | 438 | 133 | 4.18 / 78.98 | 6 | 71 |
7 | 8 | 0.12 | 208 | 15.17 | 366 | 1155 | 5.33 / 80.14 | 6 | 133 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 31 | 15.16 | 500 | 235 | 0.23 / 69.85 | 6 | 33 |
2 | 7 | 2006.88 | 40 | 14.63 | 3085 | 1805 | 2.04 / 71.65 | 33 | 56 |
3 | 13 | 1809.64 | 20 | 14.67 | 2849 | 836 | 2.88 / 72.49 | 6 | 63 |
4 | 13 | 1272.12 | 20 | 14.79 | 2126 | 629 | 3.51 / 73.12 | 6 | 71 |
5 | 13 | 700.04 | 20 | 14.96 | 1369 | 410 | 3.91 / 73.53 | 6 | 78 |
6 | 13 | 18.36 | 20 | 15.23 | 403 | 123 | 4.04 / 73.65 | 6 | 72 |
7 | 8 | 0.04 | 206 | 15.17 | 370 | 1156 | 5.19 / 74.81 | 6 | 132 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 31 | 15.16 | 517 | 243 | 0.24 / 64.70 | 6 | 36 |
2 | 7 | 2007.40 | 40 | 14.62 | 3082 | 1802 | 2.05 / 66.50 | 36 | 56 |
3 | 13 | 1803.24 | 20 | 14.69 | 2818 | 828 | 2.87 / 67.33 | 6 | 60 |
4 | 13 | 1388.32 | 20 | 14.76 | 2275 | 672 | 3.54 / 68.00 | 6 | 68 |
5 | 13 | 577.36 | 20 | 15.01 | 1193 | 358 | 3.90 / 68.36 | 6 | 80 |
6 | 13 | 22.40 | 20 | 15.23 | 404 | 123 | 4.03 / 68.48 | 6 | 74 |
7 | 8 | 0.24 | 206 | 15.17 | 363 | 1134 | 5.16 / 69.61 | 6 | 136 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 31 | 15.16 | 513 | 241 | 0.24 / 59.53 | 6 | 39 |
2 | 7 | 2009.96 | 40 | 14.63 | 3101 | 1815 | 2.06 / 61.35 | 51 | 58 |
3 | 13 | 1824.48 | 20 | 14.69 | 2844 | 836 | 2.89 / 62.18 | 6 | 63 |
4 | 13 | 1180.16 | 20 | 14.83 | 1979 | 587 | 3.48 / 62.77 | 6 | 72 |
5 | 13 | 740.72 | 20 | 14.96 | 1408 | 421 | 3.90 / 63.19 | 6 | 78 |
6 | 13 | 35.52 | 20 | 15.22 | 429 | 131 | 4.03 / 63.32 | 6 | 75 |
7 | 8 | -0.16 | 204 | 15.18 | 366 | 1133 | 5.16 / 64.45 | 6 | 132 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 31 | 15.16 | 502 | 236 | 0.24 / 54.27 | 6 | 35 |
2 | 7 | 2011.56 | 41 | 14.62 | 3101 | 1859 | 2.09 / 56.13 | 35 | 56 |
3 | 13 | 1916.48 | 20 | 14.65 | 2972 | 871 | 2.97 / 57.00 | 6 | 61 |
4 | 13 | 1360.64 | 20 | 14.78 | 2234 | 660 | 3.63 / 57.66 | 6 | 71 |
5 | 13 | 688.32 | 20 | 14.98 | 1332 | 399 | 4.02 / 58.06 | 6 | 78 |
6 | 13 | 24.12 | 20 | 15.23 | 404 | 123 | 4.15 / 58.18 | 6 | 76 |
7 | 8 | 0.00 | 201 | 15.18 | 363 | 1108 | 5.26 / 59.29 | 6 | 132 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 31 | 15.17 | 506 | 238 | 0.24 / 49.00 | 6 | 35 |
2 | 7 | 2006.48 | 41 | 14.63 | 3101 | 1860 | 2.10 / 50.86 | 60 | 56 |
3 | 13 | 1911.72 | 20 | 14.66 | 2970 | 871 | 2.97 / 51.73 | 6 | 60 |
4 | 13 | 1371.24 | 20 | 14.77 | 2256 | 666 | 3.64 / 52.40 | 6 | 70 |
5 | 13 | 609.88 | 20 | 15.01 | 1235 | 371 | 4.01 / 52.77 | 6 | 78 |
6 | 13 | 65.92 | 20 | 15.21 | 474 | 144 | 4.15 / 52.92 | 6 | 75 |
7 | 8 | 0.00 | 203 | 15.18 | 363 | 1119 | 5.27 / 54.03 | 6 | 133 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 31 | 15.17 | 507 | 238 | 0.24 / 43.81 | 6 | 38 |
2 | 7 | 2011.00 | 40 | 14.63 | 3115 | 1823 | 2.06 / 45.63 | 43 | 56 |
3 | 13 | 1919.68 | 20 | 14.66 | 3013 | 883 | 2.94 / 46.51 | 6 | 60 |
4 | 13 | 1240.44 | 20 | 14.82 | 2080 | 617 | 3.56 / 47.13 | 6 | 73 |
5 | 13 | 591.48 | 20 | 15.02 | 1214 | 365 | 3.93 / 47.50 | 6 | 79 |
6 | 13 | 16.32 | 20 | 15.24 | 403 | 123 | 4.05 / 47.62 | 6 | 75 |
7 | 8 | 0.00 | 203 | 15.18 | 372 | 1146 | 5.20 / 48.77 | 6 | 133 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 30 | 15.16 | 518 | 236 | 0.24 / 38.57 | 6 | 39 |
2 | 3 | 1029.00 | 1 | 15.18 | 1816 | 28 | 0.26 / 38.60 | 6 | 61 |
3 | 7 | 2007.32 | 40 | 14.65 | 3084 | 1807 | 2.07 / 40.41 | 61 | 54 |
4 | 13 | 1813.44 | 20 | 14.70 | 2854 | 839 | 2.91 / 41.25 | 6 | 62 |
5 | 13 | 1391.72 | 20 | 14.77 | 2303 | 680 | 3.59 / 41.93 | 6 | 70 |
6 | 13 | 689.08 | 20 | 14.98 | 1348 | 404 | 3.99 / 42.33 | 6 | 80 |
7 | 8 | 0.20 | 225 | 15.19 | 363 | 1241 | 5.23 / 43.57 | 6 | 137 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 30 | 15.17 | 511 | 233 | 0.23 / 33.32 | 6 | 41 |
2 | 7 | 2005.72 | 40 | 14.65 | 3098 | 1815 | 2.05 / 35.13 | 41 | 55 |
3 | 13 | 1805.84 | 20 | 14.71 | 2831 | 833 | 2.88 / 35.97 | 6 | 61 |
4 | 13 | 1272.44 | 20 | 14.82 | 2137 | 633 | 3.51 / 36.60 | 6 | 70 |
5 | 13 | 709.36 | 20 | 14.98 | 1383 | 414 | 3.93 / 37.02 | 6 | 78 |
6 | 13 | 115.48 | 20 | 15.20 | 552 | 168 | 4.10 / 37.18 | 6 | 69 |
7 | 8 | -0.08 | 203 | 15.18 | 374 | 1152 | 5.25 / 38.34 | 6 | 131 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 30 | 15.17 | 517 | 235 | 0.24 / 28.14 | 6 | 44 |
2 | 7 | 2007.40 | 41 | 14.65 | 3108 | 1867 | 2.10 / 30.01 | 44 | 55 |
3 | 13 | 1911.80 | 20 | 14.69 | 2961 | 870 | 2.97 / 30.88 | 6 | 58 |
4 | 13 | 1242.24 | 20 | 14.83 | 2095 | 621 | 3.59 / 31.50 | 6 | 71 |
5 | 13 | 473.76 | 20 | 15.08 | 1057 | 319 | 3.91 / 31.82 | 6 | 78 |
6 | 13 | 30.96 | 20 | 15.24 | 424 | 129 | 4.04 / 31.95 | 6 | 74 |
7 | 8 | 0.04 | 201 | 15.19 | 372 | 1136 | 5.18 / 33.09 | 6 | 134 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 29 | 15.17 | 515 | 227 | 0.23 / 22.98 | 6 | 44 |
2 | 3 | 1045.16 | 1 | 15.15 | 1855 | 28 | 0.25 / 23.01 | 6 | 66 |
3 | 7 | 2005.32 | 40 | 14.66 | 3111 | 1824 | 2.08 / 24.83 | 66 | 56 |
4 | 13 | 1802.16 | 20 | 14.71 | 2845 | 837 | 2.92 / 25.67 | 6 | 62 |
5 | 13 | 1376.44 | 20 | 14.78 | 2273 | 672 | 3.59 / 26.34 | 6 | 71 |
6 | 13 | 475.60 | 20 | 15.08 | 1061 | 320 | 3.91 / 26.66 | 6 | 78 |
7 | 8 | 0.16 | 223 | 15.19 | 369 | 1250 | 5.16 / 27.91 | 6 | 129 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 31 | 15.16 | 522 | 245 | 0.25 / 17.81 | 6 | 46 |
2 | 3 | 944.76 | -1 | 15.54 | 11 | 0 | 0.00 / 17.81 | 6 | 46 |
3 | 7 | 2006.32 | 40 | 14.68 | 3061 | 1797 | 2.04 / 19.60 | 46 | 56 |
4 | 13 | 1912.40 | 20 | 14.70 | 2971 | 873 | 2.92 / 20.48 | 6 | 62 |
5 | 13 | 1281.72 | 20 | 14.82 | 2133 | 632 | 3.55 / 21.11 | 6 | 70 |
6 | 13 | 616.52 | 20 | 15.02 | 1246 | 374 | 3.92 / 21.48 | 6 | 78 |
7 | 8 | 0.12 | 225 | 15.20 | 371 | 1269 | 5.19 / 22.75 | 6 | 138 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 29 | 15.17 | 522 | 230 | 0.23 / 13.43 | 6 | 47 |
2 | 7 | 1507.36 | 40 | 14.87 | 2408 | 1432 | 1.66 / 14.86 | 47 | 62 |
3 | 13 | 1437.04 | 20 | 14.88 | 2325 | 692 | 2.35 / 15.56 | 6 | 63 |
4 | 13 | 923.76 | 20 | 14.97 | 1673 | 501 | 2.85 / 16.06 | 6 | 75 |
5 | 13 | 383.40 | 20 | 15.13 | 936 | 283 | 3.14 / 16.34 | 6 | 78 |
6 | 8 | 0.16 | 218 | 15.21 | 368 | 1220 | 4.36 / 17.56 | 6 | 140 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 29 | 15.16 | 524 | 230 | 0.23 / 8.97 | 6 | 48 |
2 | 7 | 1505.24 | 40 | 14.86 | 2428 | 1443 | 1.67 / 10.42 | 48 | 63 |
3 | 13 | 1423.08 | 20 | 14.88 | 2323 | 691 | 2.36 / 11.11 | 6 | 66 |
4 | 13 | 1102.16 | 20 | 14.91 | 1901 | 567 | 2.93 / 11.67 | 6 | 73 |
5 | 13 | 415.40 | 20 | 15.12 | 979 | 296 | 3.23 / 11.97 | 6 | 77 |
6 | 8 | 0.08 | 219 | 15.20 | 370 | 1232 | 4.46 / 13.20 | 6 | 144 |
Average= | 3.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 31 | 15.18 | 514 | 242 | 0.24 / 4.67 | 6 | 45 |
2 | 3 | 923.44 | -1 | 15.55 | 11 | 0 | 0.00 / 4.67 | 6 | 45 |
3 | 7 | 1506.00 | 40 | 14.87 | 2404 | 1430 | 1.67 / 6.10 | 45 | 60 |
4 | 13 | 1427.20 | 20 | 14.88 | 2317 | 690 | 2.36 / 6.78 | 6 | 65 |
5 | 13 | 1011.40 | 20 | 14.94 | 1784 | 533 | 2.89 / 7.32 | 6 | 74 |
6 | 13 | 250.72 | 20 | 15.18 | 746 | 226 | 3.12 / 7.54 | 6 | 77 |
7 | 8 | 0.04 | 216 | 15.20 | 365 | 1198 | 4.32 / 8.74 | 6 | 129 |
Average= | 2.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 31 | 15.34 | 485 | 231 | 0.23 / 1.92 | 6 | 38 |
2 | 3 | 923.08 | -1 | 15.55 | 11 | 0 | 0.00 / 1.92 | 6 | 38 |
3 | 7 | 962.32 | 40 | 15.02 | 1685 | 1012 | 1.24 / 2.93 | 38 | 68 |
4 | 13 | 431.44 | 20 | 15.17 | 975 | 296 | 1.54 / 3.23 | 6 | 75 |
5 | 8 | 0.08 | 220 | 15.24 | 357 | 1197 | 2.74 / 4.42 | 6 | 133 |
Average= | 2.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 68.72 | 30 | 15.50 | 433 | 201 | 0.20 / 0.20 | 6 | 37 |
2 | 7 | 79.00 | 40 | 15.48 | 440 | 272 | 0.47 / 0.47 | 37 | 42 |
3 | 13 | 42.20 | 20 | 15.48 | 392 | 121 | 0.60 / 0.60 | 6 | 49 |
4 | 8 | 0.28 | 218 | 15.42 | 325 | 1093 | 1.69 / 1.69 | 6 | 201 |
Average= | 1.69 (KJ/cycle) |