SIO Argo Site:
Pump Diagnostics Page   



Serial= 7624 WMO= 4903356

Return

←PreviousNext→

Cycle 266 GMT 23/11/2024 1:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1154.60 -5 15.28 7 0 0.00 / 1266.25 6 7
2 7 1162.20 40 14.78 1869 1105 1.11 / 1267.36 7 57
3 13 1161.88 20 14.76 1862 550 1.66 / 1267.91 6 61
4 13 1136.92 20 14.72 1832 539 2.19 / 1268.45 6 63
5 13 783.32 20 14.76 1363 402 2.60 / 1268.85 6 69
6 13 101.12 20 14.96 448 134 2.73 / 1268.98 6 65
7 13 40.72 20 14.98 363 109 2.84 / 1269.09 6 60
8 8 0.08 225 14.94 287 965 3.80 / 1270.06 6 156
Average= 7.18
(KJ/cycle)

Cycle 265 GMT 18/11/2024 3:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1249.76 -4 15.28 6 0 0.00 / 1262.27 6 7
2 7 1250.08 40 14.74 1993 1175 1.18 / 1263.45 7 60
3 13 1249.72 20 14.72 1994 587 1.76 / 1264.03 6 60
4 13 1223.44 20 14.67 1957 574 2.34 / 1264.61 6 65
5 13 764.92 20 14.74 1357 400 2.74 / 1265.01 6 71
6 13 165.68 20 14.93 546 163 2.90 / 1265.17 6 69
7 13 50.00 20 14.97 374 112 3.01 / 1265.28 6 65
8 8 0.08 225 14.93 289 971 3.98 / 1266.25 6 162
Average= 7.19
(KJ/cycle)

Cycle 264 GMT 13/11/2024 5:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1291.36 -3 15.28 6 0 0.00 / 1258.27 6 7
2 7 1291.44 40 14.72 2055 1210 1.21 / 1259.48 7 58
3 13 1284.08 20 14.70 2055 604 1.81 / 1260.09 6 62
4 13 1254.88 20 14.66 2004 588 2.40 / 1260.67 6 63
5 13 691.36 20 14.76 1269 375 2.78 / 1261.05 6 71
6 13 98.12 20 14.95 448 134 2.91 / 1261.18 6 64
7 13 32.72 20 14.97 354 106 3.02 / 1261.29 6 63
8 8 -0.08 225 14.93 292 981 4.00 / 1262.27 6 164
Average= 7.21
(KJ/cycle)

Cycle 263 GMT 8/11/2024 7: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1326.76 -3 15.28 6 0 0.00 / 1254.16 6 7
2 7 1327.12 40 14.71 2099 1235 1.24 / 1255.40 7 57
3 13 1316.96 20 14.68 2089 613 1.85 / 1256.01 6 60
4 13 1286.88 20 14.64 2049 600 2.45 / 1256.61 6 62
5 13 875.96 20 14.70 1510 444 2.89 / 1257.05 6 70
6 13 116.28 20 14.94 474 142 3.03 / 1257.20 6 69
7 13 46.60 20 14.96 374 112 3.15 / 1257.31 6 64
8 8 0.12 223 14.93 290 966 4.11 / 1258.27 6 136
Average= 7.23
(KJ/cycle)

Cycle 262 GMT 3/11/2024 8:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1339.44 -3 15.28 6 0 0.00 / 1250.06 6 7
2 7 1339.44 41 14.70 2113 1274 1.27 / 1251.34 7 56
3 13 1323.92 20 14.68 2102 617 1.89 / 1251.95 6 58
4 13 1261.68 20 14.64 2013 589 2.48 / 1252.54 6 62
5 13 779.92 20 14.73 1381 407 2.89 / 1252.95 6 70
6 13 97.12 20 14.95 443 132 3.02 / 1253.08 6 59
7 13 31.24 20 14.97 351 105 3.12 / 1253.19 6 60
8 8 -0.12 225 14.93 290 974 4.10 / 1254.16 6 172
Average= 7.25
(KJ/cycle)

Cycle 261 GMT 29/10/2024 10:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1332.72 -3 15.28 6 0 0.00 / 1245.99 6 7
2 7 1332.92 41 14.70 2100 1266 1.27 / 1247.25 7 56
3 13 1323.20 20 14.67 2093 614 1.88 / 1247.87 6 61
4 13 1293.56 20 14.64 2048 600 2.48 / 1248.47 6 60
5 13 791.52 20 14.72 1392 410 2.89 / 1248.88 6 72
6 13 82.40 20 14.96 420 126 3.02 / 1249.00 6 60
7 13 26.32 20 14.97 337 101 3.12 / 1249.10 6 61
8 8 0.00 225 14.93 286 961 4.08 / 1250.06 6 140
Average= 7.27
(KJ/cycle)

Cycle 260 GMT 24/10/2024 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1327.32 -3 15.28 6 0 0.00 / 1241.93 6 7
2 7 1327.32 40 14.70 2098 1234 1.23 / 1243.16 7 59
3 13 1311.00 20 14.68 2079 610 1.84 / 1243.77 6 59
4 13 1248.88 20 14.64 1997 585 2.43 / 1244.36 6 62
5 13 740.04 20 14.74 1326 391 2.82 / 1244.75 6 72
6 13 169.80 20 14.92 548 164 2.98 / 1244.91 6 69
7 13 25.76 20 14.97 341 102 3.09 / 1245.01 6 61
8 8 -0.04 225 14.93 290 974 4.06 / 1245.99 6 137
Average= 7.29
(KJ/cycle)

Cycle 259 GMT 19/10/2024 14:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1331.48 -3 15.28 6 0 0.00 / 1237.84 6 7
2 7 1331.28 40 14.70 2099 1234 1.23 / 1239.08 7 58
3 13 1318.32 20 14.69 2091 614 1.85 / 1239.69 6 60
4 13 1289.16 20 14.64 2055 602 2.45 / 1240.29 6 62
5 13 818.00 20 14.71 1433 422 2.87 / 1240.72 6 70
6 13 107.60 20 14.95 461 138 3.01 / 1240.85 6 65
7 13 39.92 20 14.97 357 107 3.12 / 1240.96 6 60
8 8 0.12 227 14.93 285 966 4.08 / 1241.93 6 -99
Average= 7.31
(KJ/cycle)

Cycle 258 GMT 14/10/2024 16: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1324.00 -3 15.28 7 0 0.00 / 1233.78 6 7
2 7 1324.12 40 14.71 2088 1229 1.23 / 1235.01 7 60
3 13 1313.08 20 14.69 2076 610 1.84 / 1235.62 6 61
4 13 1283.84 20 14.64 2046 599 2.44 / 1236.22 6 62
5 13 738.56 20 14.74 1327 391 2.83 / 1236.61 6 70
6 13 169.64 20 14.92 551 164 2.99 / 1236.77 6 71
7 13 29.96 20 14.97 348 104 3.10 / 1236.88 6 61
8 8 0.08 225 14.93 288 967 4.07 / 1237.84 6 150
Average= 7.32
(KJ/cycle)

Cycle 257 GMT 9/10/2024 17:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1330.52 -3 15.28 7 0 0.00 / 1229.70 6 7
2 7 1330.16 40 14.71 2104 1238 1.24 / 1230.94 7 59
3 13 1329.76 20 14.68 2111 620 1.86 / 1231.56 6 60
4 13 1302.96 20 14.64 2071 606 2.46 / 1232.17 6 62
5 13 723.88 20 14.74 1310 386 2.85 / 1232.55 6 71
6 13 139.76 20 14.92 516 154 3.00 / 1232.71 6 73
7 13 40.68 20 14.96 366 110 3.11 / 1232.82 6 62
8 8 0.04 225 14.93 287 964 4.08 / 1233.78 6 137
Average= 7.34
(KJ/cycle)

Cycle 256 GMT 4/10/2024 19:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1343.16 -2 15.28 6 0 0.00 / 1225.59 6 7
2 7 1343.12 40 14.70 2120 1247 1.25 / 1226.84 7 59
3 13 1334.64 20 14.68 2112 620 1.87 / 1227.46 6 59
4 13 1304.56 20 14.63 2065 604 2.47 / 1228.06 6 61
5 13 824.72 20 14.71 1444 425 2.90 / 1228.49 6 71
6 13 101.84 20 14.94 456 136 3.03 / 1228.62 6 65
7 13 33.80 20 14.96 356 107 3.14 / 1228.73 6 64
8 8 0.04 225 14.93 289 971 4.11 / 1229.70 6 148
Average= 7.36
(KJ/cycle)

Cycle 255 GMT 29/ 9/2024 21:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1353.20 -2 15.28 7 0 0.00 / 1221.44 6 7
2 7 1352.88 40 14.70 2133 1254 1.25 / 1222.69 7 58
3 13 1352.48 20 14.67 2138 627 1.88 / 1223.32 6 61
4 13 1325.96 20 14.62 2093 612 2.49 / 1223.93 6 61
5 13 777.72 20 14.72 1380 406 2.90 / 1224.34 6 71
6 13 174.84 20 14.91 559 167 3.07 / 1224.50 6 70
7 13 30.72 20 14.96 348 104 3.17 / 1224.61 6 64
8 8 0.04 225 14.92 293 984 4.15 / 1225.59 6 134
Average= 7.38
(KJ/cycle)

Cycle 254 GMT 24/ 9/2024 23: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1331.80 -3 15.28 7 0 0.00 / 1217.32 6 7
2 7 1331.44 40 14.71 2104 1238 1.24 / 1218.56 7 59
3 13 1322.24 20 14.68 2095 615 1.85 / 1219.18 6 59
4 13 1292.72 20 14.64 2061 603 2.46 / 1219.78 6 63
5 13 847.88 20 14.71 1468 432 2.89 / 1220.21 6 69
6 13 132.28 20 14.93 498 149 3.04 / 1220.36 6 69
7 13 32.88 20 14.96 351 105 3.14 / 1220.47 6 61
8 8 0.16 227 14.93 287 973 4.12 / 1221.44 6 -99
Average= 7.40
(KJ/cycle)

Cycle 253 GMT 20/ 9/2024 1: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1308.72 -3 15.28 7 0 0.00 / 1213.23 6 7
2 7 1308.56 40 14.71 2072 1219 1.22 / 1214.45 7 57
3 13 1308.20 20 14.68 2078 610 1.83 / 1215.06 6 60
4 13 1281.52 20 14.64 2050 600 2.43 / 1215.66 6 60
5 13 867.32 20 14.70 1499 441 2.87 / 1216.10 6 70
6 13 151.88 20 14.92 523 156 3.03 / 1216.26 6 66
7 13 39.36 20 14.96 356 107 3.13 / 1216.37 6 62
8 8 0.00 225 14.92 285 957 4.09 / 1217.32 6 149
Average= 7.42
(KJ/cycle)

Cycle 252 GMT 15/ 9/2024 2:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1241.96 -4 15.27 6 0 0.00 / 1209.27 6 7
2 7 1242.08 41 14.74 1972 1192 1.19 / 1210.47 7 58
3 13 1232.80 20 14.72 1974 581 1.77 / 1211.05 6 62
4 13 1204.76 20 14.68 1921 564 2.34 / 1211.61 6 62
5 13 843.84 20 14.72 1456 429 2.77 / 1212.04 6 69
6 13 91.16 20 14.95 435 130 2.90 / 1212.17 6 62
7 13 29.24 20 14.97 345 103 3.00 / 1212.27 6 58
8 8 0.00 225 14.93 286 961 3.96 / 1213.23 6 208
Average= 7.44
(KJ/cycle)

Cycle 251 GMT 10/ 9/2024 4:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1217.92 -4 15.27 7 0 0.00 / 1205.42 6 7
2 7 1217.96 40 14.74 1963 1157 1.16 / 1206.58 7 59
3 13 1217.64 20 14.72 1964 578 1.74 / 1207.16 6 59
4 13 1196.32 20 14.68 1932 567 2.30 / 1207.72 6 62
5 13 720.84 20 14.75 1300 383 2.69 / 1208.11 6 71
6 13 71.24 20 14.96 406 121 2.81 / 1208.23 6 63
7 13 22.32 20 14.97 337 101 2.91 / 1208.33 6 58
8 8 0.12 218 14.93 290 944 3.85 / 1209.27 6 135
Average= 7.46
(KJ/cycle)

Cycle 250 GMT 5/ 9/2024 6:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1230.80 -4 15.28 7 0 0.00 / 1201.54 6 7
2 7 1230.68 40 14.75 1972 1163 1.16 / 1202.71 7 58
3 13 1220.40 20 14.72 1962 578 1.74 / 1203.29 6 61
4 13 1191.52 20 14.68 1922 564 2.31 / 1203.85 6 64
5 13 758.20 20 14.74 1355 399 2.71 / 1204.25 6 69
6 13 91.24 20 14.95 432 129 2.83 / 1204.38 6 57
7 13 32.52 20 14.96 344 103 2.94 / 1204.48 6 58
8 8 0.08 225 14.93 280 941 3.88 / 1205.42 6 -99
Average= 7.49
(KJ/cycle)

Cycle 249 GMT 31/ 8/2024 8:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1197.00 -5 15.27 7 0 0.00 / 1197.70 6 7
2 7 1199.56 40 14.77 1929 1140 1.14 / 1198.84 7 58
3 13 1199.20 20 14.74 1935 570 1.71 / 1199.41 6 58
4 13 1176.36 20 14.70 1900 559 2.27 / 1199.97 6 62
5 13 750.28 20 14.75 1336 394 2.66 / 1200.36 6 69
6 13 107.40 20 14.95 459 137 2.80 / 1200.50 6 63
7 13 22.40 20 14.97 333 100 2.90 / 1200.60 6 60
8 8 0.04 225 14.94 282 948 3.85 / 1201.54 6 167
Average= 7.51
(KJ/cycle)

Cycle 248 GMT 26/ 8/2024 10:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1057.76 -7 15.26 6 0 0.00 / 1194.02 6 7
2 7 1071.28 40 14.81 1748 1036 1.04 / 1195.05 7 61
3 13 1070.96 20 14.79 1753 519 1.55 / 1195.57 6 61
4 13 1052.52 20 14.75 1725 509 2.06 / 1196.08 6 65
5 13 825.44 20 14.76 1424 420 2.48 / 1196.50 6 69
6 13 90.92 20 14.95 441 132 2.62 / 1196.63 6 70
7 13 28.08 20 14.97 345 103 2.72 / 1196.74 6 64
8 8 0.12 223 14.93 288 959 3.68 / 1197.70 6 138
Average= 7.53
(KJ/cycle)

Cycle 247 GMT 21/ 8/2024 13:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1031.96 -7 15.26 7 0 0.00 / 1190.50 6 7
2 7 1032.96 40 14.83 1696 1006 1.01 / 1191.51 7 59
3 13 1032.64 20 14.80 1712 507 1.51 / 1192.02 6 64
4 13 1009.60 20 14.77 1680 496 2.01 / 1192.51 6 65
5 13 589.36 20 14.82 1118 331 2.34 / 1192.84 6 73
6 13 69.52 20 14.96 412 123 2.46 / 1192.97 6 67
7 13 22.52 20 14.97 341 102 2.57 / 1193.07 6 62
8 8 0.08 220 14.93 289 949 3.52 / 1194.02 6 146
Average= 7.56
(KJ/cycle)

Cycle 246 GMT 16/ 8/2024 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1004.64 -8 15.26 7 0 0.00 / 1186.47 6 7
2 7 1005.28 40 14.83 1672 992 0.99 / 1187.46 7 62
3 13 1004.96 20 14.81 1678 497 1.49 / 1187.96 6 63
4 13 1005.00 20 14.77 1666 492 1.98 / 1188.45 6 65
5 13 1005.00 20 14.72 1670 492 2.47 / 1188.94 6 66
6 13 1004.96 20 14.67 1668 489 2.96 / 1189.43 6 68
7 13 30.76 20 14.97 354 106 3.07 / 1189.54 6 69
8 8 0.08 223 14.93 291 969 4.04 / 1190.50 6 130
Average= 7.58
(KJ/cycle)

Cycle 245 GMT 11/ 8/2024 18:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1033.12 -7 15.27 7 0 0.00 / 1182.91 6 7
2 7 1033.08 40 14.83 1699 1008 1.01 / 1183.92 7 60
3 13 1032.80 20 14.81 1697 503 1.51 / 1184.42 6 63
4 13 1012.64 20 14.77 1664 492 2.00 / 1184.91 6 64
5 13 592.12 20 14.82 1116 331 2.33 / 1185.25 6 72
6 13 132.64 20 14.94 502 150 2.48 / 1185.40 6 74
7 13 26.24 20 14.97 344 103 2.59 / 1185.50 6 68
8 8 0.04 220 14.93 295 969 3.56 / 1186.47 6 132
Average= 7.61
(KJ/cycle)

Cycle 244 GMT 6/ 8/2024 21: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1112.92 -6 15.27 6 0 0.00 / 1179.22 6 7
2 7 1113.00 40 14.80 1805 1069 1.07 / 1180.29 7 57
3 13 1112.64 20 14.77 1802 532 1.60 / 1180.83 6 63
4 13 1092.04 20 14.73 1785 526 2.13 / 1181.35 6 64
5 13 698.80 20 14.78 1269 375 2.50 / 1181.73 6 72
6 13 67.48 20 14.96 405 121 2.62 / 1181.85 6 65
7 13 19.04 20 14.97 333 100 2.72 / 1181.95 6 61
8 8 0.04 223 14.93 290 966 3.69 / 1182.91 6 137
Average= 7.63
(KJ/cycle)

Cycle 243 GMT 1/ 8/2024 23:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1122.52 -6 15.27 6 0 0.00 / 1175.51 6 7
2 7 1122.04 40 14.80 1815 1074 1.08 / 1176.58 7 56
3 13 1121.72 20 14.78 1810 535 1.61 / 1177.12 6 62
4 13 1104.40 20 14.73 1789 527 2.14 / 1177.64 6 63
5 13 718.92 20 14.77 1295 383 2.52 / 1178.03 6 71
6 13 88.04 20 14.95 432 129 2.65 / 1178.15 6 63
7 13 28.04 20 14.97 342 102 2.75 / 1178.26 6 57
8 8 0.08 225 14.93 288 967 3.72 / 1179.22 6 250
Average= 7.66
(KJ/cycle)

Cycle 242 GMT 28/ 7/2024 1:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1164.04 -5 15.28 7 0 0.00 / 1171.73 6 7
2 7 1163.80 40 14.77 1886 1114 1.11 / 1172.84 7 60
3 13 1163.44 20 14.75 1888 557 1.67 / 1173.40 6 61
4 13 1137.80 20 14.71 1850 544 2.22 / 1173.94 6 62
5 13 674.52 20 14.78 1238 366 2.58 / 1174.31 6 72
6 13 107.40 20 14.94 458 137 2.72 / 1174.45 6 69
7 13 37.32 20 14.96 355 106 2.83 / 1174.55 6 62
8 8 0.04 223 14.93 286 952 3.78 / 1175.51 6 140
Average= 7.68
(KJ/cycle)

Cycle 241 GMT 23/ 7/2024 3:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1236.28 -4 15.28 7 0 0.00 / 1167.88 6 7
2 7 1235.68 40 14.75 1973 1164 1.16 / 1169.04 7 59
3 13 1235.32 20 14.72 1984 584 1.75 / 1169.62 6 60
4 13 1212.52 20 14.68 1944 571 2.32 / 1170.19 6 63
5 13 673.60 20 14.76 1236 365 2.68 / 1170.56 6 72
6 13 75.08 20 14.96 406 121 2.81 / 1170.68 6 61
7 13 23.60 20 14.97 334 100 2.91 / 1170.78 6 56
8 8 0.08 223 14.93 285 949 3.85 / 1171.73 6 132
Average= 7.71
(KJ/cycle)

Cycle 240 GMT 18/ 7/2024 5:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1286.00 -3 15.28 6 0 0.00 / 1163.88 6 7
2 7 1285.76 40 14.73 2044 1204 1.20 / 1165.09 7 56
3 13 1275.76 20 14.70 2034 598 1.80 / 1165.69 6 59
4 13 1246.68 20 14.66 1997 586 2.39 / 1166.27 6 61
5 13 737.68 20 14.74 1323 390 2.78 / 1166.66 6 70
6 13 129.68 20 14.93 492 147 2.93 / 1166.81 6 64
7 13 28.76 20 14.96 344 103 3.03 / 1166.91 6 57
8 8 -0.08 225 14.92 287 963 3.99 / 1167.88 6 164
Average= 7.73
(KJ/cycle)

Cycle 239 GMT 13/ 7/2024 7:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1310.32 -3 15.28 6 0 0.00 / 1159.87 6 7
2 7 1309.96 40 14.72 2073 1221 1.22 / 1161.09 7 59
3 13 1294.64 20 14.70 2056 604 1.83 / 1161.70 6 61
4 13 1264.52 20 14.66 2012 590 2.42 / 1162.29 6 63
5 13 726.56 20 14.74 1309 386 2.80 / 1162.67 6 72
6 13 126.32 20 14.93 485 145 2.95 / 1162.82 6 65
7 13 27.28 20 14.96 340 102 3.05 / 1162.92 6 60
8 8 0.00 225 14.92 287 963 4.01 / 1163.88 6 139
Average= 7.76
(KJ/cycle)

Cycle 238 GMT 8/ 7/2024 9:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1322.80 -3 15.28 6 0 0.00 / 1155.77 6 7
2 7 1322.68 41 14.71 2094 1263 1.26 / 1157.03 7 58
3 13 1322.28 20 14.69 2099 617 1.88 / 1157.65 6 60
4 13 1296.04 20 14.64 2063 604 2.48 / 1158.25 6 61
5 13 782.56 20 14.72 1389 409 2.89 / 1158.66 6 70
6 13 115.96 20 14.93 472 141 3.03 / 1158.80 6 65
7 13 23.52 20 14.96 335 100 3.13 / 1158.90 6 60
8 8 -0.04 225 14.92 289 970 4.10 / 1159.87 6 154
Average= 7.78
(KJ/cycle)

Cycle 237 GMT 3/ 7/2024 11: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1332.16 -3 15.28 7 0 0.00 / 1151.72 6 7
2 7 1332.28 40 14.71 2107 1240 1.24 / 1152.96 7 58
3 13 1317.76 20 14.69 2088 613 1.85 / 1153.57 6 60
4 13 1288.16 20 14.65 2048 600 2.45 / 1154.17 6 61
5 13 743.12 20 14.73 1331 392 2.85 / 1154.56 6 71
6 13 118.72 20 14.93 473 141 2.99 / 1154.71 6 66
7 13 22.96 20 14.96 335 100 3.09 / 1154.81 6 59
8 8 0.12 225 14.92 287 963 4.05 / 1155.77 6 133
Average= 7.81
(KJ/cycle)

Cycle 236 GMT 28/ 6/2024 12:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1326.88 -3 15.28 6 0 0.00 / 1147.66 6 7
2 7 1326.92 40 14.72 2082 1226 1.23 / 1148.89 7 56
3 13 1326.52 20 14.69 2101 617 1.84 / 1149.51 6 59
4 13 1300.52 20 14.64 2060 603 2.45 / 1150.11 6 61
5 13 825.52 20 14.71 1444 425 2.87 / 1150.53 6 70
6 13 79.56 20 14.95 419 125 3.00 / 1150.66 6 61
7 13 25.36 20 14.96 336 101 3.10 / 1150.76 6 60
8 8 0.04 225 14.92 286 960 4.06 / 1151.72 6 160
Average= 7.83
(KJ/cycle)

Cycle 235 GMT 23/ 6/2024 14:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1323.96 -3 15.29 6 0 0.00 / 1143.63 6 7
2 7 1324.36 40 14.72 2094 1233 1.23 / 1144.87 7 57
3 13 1311.92 20 14.70 2077 611 1.84 / 1145.48 6 60
4 13 1281.52 20 14.65 2049 600 2.44 / 1146.08 6 59
5 13 735.20 20 14.74 1323 390 2.83 / 1146.47 6 71
6 13 94.28 20 14.94 439 131 2.97 / 1146.60 6 65
7 13 16.40 20 14.96 324 97 3.06 / 1146.70 6 59
8 8 -0.16 225 14.92 288 967 4.03 / 1147.66 6 -99
Average= 7.86
(KJ/cycle)

Cycle 234 GMT 18/ 6/2024 16:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1390.96 -2 15.28 6 0 0.00 / 1139.45 6 7
2 7 1391.32 40 14.69 2181 1282 1.28 / 1140.74 7 58
3 13 1376.64 20 14.68 2163 635 1.92 / 1141.37 6 58
4 13 1346.60 20 14.62 2122 620 2.54 / 1141.99 6 59
5 13 860.36 20 14.69 1486 437 2.97 / 1142.43 6 68
6 13 110.48 20 14.94 462 138 3.11 / 1142.57 6 64
7 13 20.20 20 14.96 328 98 3.21 / 1142.66 6 60
8 8 0.08 227 14.92 286 969 4.18 / 1143.63 6 -99
Average= 7.89
(KJ/cycle)

Cycle 233 GMT 13/ 6/2024 18: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1451.04 -1 15.28 6 0 0.00 / 1135.14 6 7
2 7 1451.44 40 14.68 2258 1326 1.33 / 1136.46 7 55
3 13 1434.60 20 14.65 2243 657 1.98 / 1137.12 6 57
4 13 1405.12 20 14.61 2203 644 2.63 / 1137.76 6 60
5 13 853.60 20 14.69 1479 435 3.06 / 1138.20 6 69
6 13 180.44 20 14.91 562 168 3.23 / 1138.37 6 67
7 13 29.32 20 14.95 343 103 3.33 / 1138.47 6 62
8 8 0.04 227 14.92 291 986 4.32 / 1139.45 6 140
Average= 7.91
(KJ/cycle)

Cycle 232 GMT 8/ 6/2024 19:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1465.12 -1 15.28 7 0 0.00 / 1130.82 6 7
2 7 1465.44 41 14.66 2280 1370 1.37 / 1132.19 7 57
3 13 1445.56 20 14.64 2258 661 2.03 / 1132.85 6 58
4 13 1382.92 20 14.60 2175 635 2.67 / 1133.48 6 60
5 13 825.68 20 14.70 1444 425 3.09 / 1133.91 6 70
6 13 128.64 20 14.92 497 148 3.24 / 1134.06 6 69
7 13 27.44 20 14.95 346 103 3.34 / 1134.16 6 64
8 8 0.04 227 14.92 289 979 4.32 / 1135.14 6 209
Average= 7.94
(KJ/cycle)

Cycle 231 GMT 3/ 6/2024 21:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1456.20 -1 15.28 7 0 0.00 / 1126.42 6 7
2 7 1456.28 40 14.67 2264 1329 1.33 / 1127.74 7 54
3 13 1438.88 20 14.65 2255 661 1.99 / 1128.41 6 57
4 13 1377.60 20 14.61 2167 633 2.62 / 1129.04 6 60
5 13 856.44 20 14.69 1483 436 3.06 / 1129.47 6 68
6 13 358.40 20 14.83 817 242 3.30 / 1129.72 6 74
7 13 17.68 20 14.95 338 101 3.40 / 1129.82 6 66
8 8 0.00 227 14.91 295 998 4.40 / 1130.82 6 139
Average= 7.96
(KJ/cycle)

Cycle 230 GMT 29/ 5/2024 22:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1425.28 -1 15.28 7 0 0.00 / 1122.14 6 7
2 7 1425.52 40 14.68 2230 1309 1.31 / 1123.45 7 57
3 13 1409.44 20 14.66 2213 649 1.96 / 1124.10 6 58
4 13 1379.84 20 14.61 2168 633 2.59 / 1124.73 6 60
5 13 932.16 20 14.67 1582 464 3.06 / 1125.20 6 67
6 13 135.28 20 14.92 502 150 3.21 / 1125.34 6 64
7 13 27.80 20 14.96 342 102 3.31 / 1125.45 6 63
8 8 0.20 227 14.92 286 969 4.28 / 1126.42 6 153
Average= 7.99
(KJ/cycle)

Cycle 229 GMT 25/ 5/2024 0:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1398.04 -2 15.28 6 0 0.00 / 1117.99 6 7
2 7 1397.72 41 14.69 2186 1317 1.32 / 1119.30 7 55
3 13 1381.52 20 14.67 2166 636 1.95 / 1119.94 6 58
4 13 1320.00 20 14.63 2096 613 2.57 / 1120.55 6 61
5 13 803.52 20 14.71 1413 416 2.98 / 1120.97 6 70
6 13 89.44 20 14.95 433 129 3.11 / 1121.10 6 63
7 8 0.12 244 14.93 286 1042 4.15 / 1122.14 6 131
Average= 8.02
(KJ/cycle)

Cycle 228 GMT 20/ 5/2024 2:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1406.36 -1 15.28 7 0 0.00 / 1113.77 6 7
2 7 1406.24 40 14.69 2199 1292 1.29 / 1115.06 7 56
3 13 1396.20 20 14.67 2194 644 1.94 / 1115.70 6 57
4 13 1366.92 20 14.62 2143 627 2.56 / 1116.33 6 62
5 13 910.12 20 14.68 1547 454 3.02 / 1116.78 6 69
6 13 120.24 20 14.93 476 142 3.16 / 1116.92 6 64
7 13 10.32 20 14.97 312 93 3.25 / 1117.02 6 58
8 8 0.08 227 14.92 286 969 4.22 / 1117.99 6 195
Average= 8.04
(KJ/cycle)

Cycle 227 GMT 15/ 5/2024 3:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1386.36 -2 15.28 7 0 0.00 / 1109.60 6 7
2 7 1386.00 40 14.70 2172 1277 1.28 / 1110.88 7 56
3 13 1370.36 20 14.68 2162 635 1.91 / 1111.51 6 60
4 13 1341.36 20 14.63 2121 621 2.53 / 1112.14 6 60
5 13 856.16 20 14.70 1479 435 2.97 / 1112.57 6 70
6 13 103.00 20 14.94 449 134 3.10 / 1112.70 6 61
7 13 16.08 20 14.97 325 97 3.20 / 1112.80 6 59
8 8 0.04 225 14.93 287 964 4.16 / 1113.77 6 135
Average= 8.07
(KJ/cycle)

Cycle 226 GMT 10/ 5/2024 5:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1385.24 -2 15.28 6 0 0.00 / 1105.48 6 7
2 7 1384.68 40 14.70 2166 1274 1.27 / 1106.75 7 55
3 13 1384.28 20 14.68 2166 636 1.91 / 1107.39 6 57
4 13 1368.36 20 14.62 2155 630 2.54 / 1108.02 6 60
5 13 749.56 20 14.73 1337 394 2.93 / 1108.41 6 71
6 13 115.12 20 14.93 469 140 3.07 / 1108.55 6 63
7 8 0.12 244 14.93 288 1049 4.12 / 1109.60 6 132
Average= 8.10
(KJ/cycle)

Cycle 225 GMT 5/ 5/2024 7:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1367.60 -2 15.28 6 0 0.00 / 1101.36 6 7
2 7 1367.32 41 14.70 2157 1300 1.30 / 1102.66 7 58
3 13 1354.12 20 14.68 2142 629 1.93 / 1103.29 6 57
4 13 1324.16 20 14.63 2100 614 2.54 / 1103.91 6 60
5 13 740.12 20 14.74 1329 392 2.94 / 1104.30 6 69
6 13 97.16 20 14.94 444 133 3.07 / 1104.43 6 57
7 8 0.00 244 14.92 288 1048 4.12 / 1105.48 6 137
Average= 8.13
(KJ/cycle)

Cycle 224 GMT 30/ 4/2024 9: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1295.84 -3 15.28 6 0 0.00 / 1097.34 6 7
2 7 1295.32 40 14.74 2057 1213 1.21 / 1098.55 7 58
3 13 1294.92 20 14.72 2056 605 1.82 / 1099.16 6 59
4 13 1268.44 20 14.67 2023 594 2.41 / 1099.75 6 61
5 13 797.88 20 14.74 1406 414 2.83 / 1100.17 6 68
6 13 84.44 20 14.95 428 128 2.95 / 1100.30 6 60
7 8 -0.08 246 14.93 291 1069 4.02 / 1101.36 6 174
Average= 8.16
(KJ/cycle)

Cycle 223 GMT 25/ 4/2024 10:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1298.96 -3 15.28 7 0 0.00 / 1093.33 6 7
2 7 1299.12 41 14.73 2063 1246 1.25 / 1094.57 7 58
3 13 1295.28 20 14.71 2054 604 1.85 / 1095.18 6 61
4 13 1265.52 20 14.66 2019 592 2.44 / 1095.77 6 61
5 13 757.16 20 14.74 1350 398 2.84 / 1096.17 6 70
6 13 81.04 20 14.96 418 125 2.97 / 1096.29 6 61
7 8 0.08 244 14.93 288 1049 4.01 / 1097.34 6 140
Average= 8.19
(KJ/cycle)

Cycle 222 GMT 20/ 4/2024 12:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1314.04 -3 15.28 6 0 0.00 / 1089.31 6 7
2 7 1313.76 40 14.73 2076 1223 1.22 / 1090.53 7 58
3 13 1312.24 20 14.70 2080 612 1.83 / 1091.14 6 59
4 13 1282.08 20 14.65 2043 599 2.43 / 1091.74 6 62
5 13 780.80 20 14.73 1380 407 2.84 / 1092.15 6 68
6 13 101.96 20 14.95 448 134 2.97 / 1092.28 6 61
7 8 0.00 244 14.93 287 1046 4.02 / 1093.33 6 137
Average= 8.22
(KJ/cycle)

Cycle 221 GMT 15/ 4/2024 14:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1328.56 -3 15.29 6 0 0.00 / 1085.28 6 7
2 7 1328.68 40 14.72 2101 1237 1.24 / 1086.51 7 56
3 13 1316.04 20 14.70 2089 614 1.85 / 1087.13 6 60
4 13 1285.80 20 14.65 2051 601 2.45 / 1087.73 6 62
5 13 732.40 20 14.75 1318 389 2.84 / 1088.12 6 70
6 13 129.60 20 14.94 484 145 2.99 / 1088.26 6 64
7 8 0.16 244 14.93 287 1046 4.03 / 1089.31 6 138
Average= 8.25
(KJ/cycle)

Cycle 220 GMT 10/ 4/2024 16:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1356.00 -2 15.28 6 0 0.00 / 1081.13 6 7
2 7 1356.08 41 14.70 2137 1288 1.29 / 1082.41 7 57
3 13 1355.68 20 14.68 2142 629 1.92 / 1083.04 6 58
4 13 1335.68 20 14.63 2104 616 2.53 / 1083.66 6 61
5 13 850.92 20 14.70 1476 434 2.97 / 1084.09 6 68
6 13 139.64 20 14.94 499 149 3.12 / 1084.24 6 61
7 8 -0.12 244 14.93 284 1035 4.15 / 1085.28 6 130
Average= 8.28
(KJ/cycle)

Cycle 219 GMT 5/ 4/2024 18:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1274.40 -4 15.28 6 0 0.00 / 1077.19 6 7
2 7 1274.56 40 14.74 2015 1188 1.19 / 1078.38 7 59
3 13 1262.64 20 14.72 2022 595 1.78 / 1078.98 6 62
4 13 1234.28 20 14.68 1982 582 2.37 / 1079.56 6 63
5 13 755.96 20 14.75 1354 399 2.77 / 1079.96 6 70
6 13 87.00 20 14.96 427 128 2.89 / 1080.09 6 60
7 8 0.12 244 14.94 285 1039 3.93 / 1081.13 6 134
Average= 8.32
(KJ/cycle)

Cycle 218 GMT 31/ 3/2024 20:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1272.92 -4 15.27 6 0 0.00 / 1073.26 6 7
2 7 1273.20 40 14.74 2032 1198 1.20 / 1074.46 7 56
3 13 1259.40 20 14.72 2019 594 1.79 / 1075.05 6 60
4 13 1230.92 20 14.68 1975 580 2.37 / 1075.63 6 61
5 13 725.88 20 14.75 1316 388 2.76 / 1076.02 6 72
6 13 84.44 20 14.96 422 126 2.89 / 1076.15 6 60
7 8 0.08 242 14.93 290 1048 3.93 / 1077.19 6 139
Average= 8.35
(KJ/cycle)

Cycle 217 GMT 26/ 3/2024 22:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1277.04 -3 15.27 7 0 0.00 / 1069.27 6 7
2 7 1277.04 40 14.74 2031 1197 1.20 / 1070.47 7 58
3 13 1276.68 20 14.72 2034 599 1.80 / 1071.07 6 63
4 13 1249.96 20 14.67 1992 584 2.38 / 1071.65 6 63
5 13 814.84 20 14.73 1430 421 2.80 / 1072.07 6 71
6 13 101.56 20 14.95 450 135 2.94 / 1072.21 6 64
7 8 -0.12 244 14.93 289 1053 3.99 / 1073.26 6 154
Average= 8.38
(KJ/cycle)

Cycle 216 GMT 22/ 3/2024 0:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1265.52 -4 15.28 6 0 0.00 / 1065.28 6 7
2 7 1265.88 40 14.74 2016 1189 1.19 / 1066.46 7 58
3 13 1265.20 20 14.72 2019 594 1.78 / 1067.06 6 61
4 13 1236.80 20 14.68 1962 576 2.36 / 1067.63 6 60
5 13 770.56 20 14.75 1353 399 2.76 / 1068.03 6 67
6 13 199.08 20 14.91 589 176 2.93 / 1068.21 6 69
7 8 -0.12 242 14.92 294 1062 4.00 / 1069.27 6 142
Average= 8.42
(KJ/cycle)

Cycle 215 GMT 17/ 3/2024 2:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1267.24 -4 15.28 7 0 0.00 / 1061.33 6 7
2 7 1267.20 40 14.74 2022 1192 1.19 / 1062.52 7 60
3 13 1257.92 20 14.72 2008 591 1.78 / 1063.11 6 62
4 13 1228.96 20 14.68 1970 578 2.36 / 1063.69 6 65
5 13 759.44 20 14.75 1360 401 2.76 / 1064.09 6 70
6 13 84.76 20 14.96 430 129 2.89 / 1064.22 6 62
7 8 -0.04 242 14.93 292 1055 3.95 / 1065.28 6 131
Average= 8.45
(KJ/cycle)

Cycle 214 GMT 12/ 3/2024 4:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1269.48 -4 15.28 6 0 0.00 / 1057.33 6 7
2 7 1269.56 41 14.74 2023 1223 1.22 / 1058.55 7 58
3 13 1256.56 20 14.72 2002 589 1.81 / 1059.14 6 60
4 13 1228.04 20 14.68 1950 573 2.38 / 1059.71 6 62
5 13 788.40 20 14.74 1395 411 2.80 / 1060.12 6 69
6 13 131.88 20 14.94 495 148 2.94 / 1060.27 6 66
7 8 0.20 242 14.93 293 1059 4.00 / 1061.33 6 134
Average= 8.49
(KJ/cycle)

Cycle 213 GMT 7/ 3/2024 6:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1243.16 -4 15.28 6 0 0.00 / 1053.39 6 7
2 7 1243.00 40 14.75 1989 1174 1.17 / 1054.57 7 59
3 13 1231.96 20 14.73 1986 585 1.76 / 1055.15 6 60
4 13 1203.48 20 14.69 1941 570 2.33 / 1055.72 6 63
5 13 803.68 20 14.74 1412 416 2.75 / 1056.14 6 70
6 13 117.96 20 14.95 471 141 2.89 / 1056.28 6 62
7 8 -0.16 242 14.93 290 1048 3.93 / 1057.33 6 131
Average= 8.53
(KJ/cycle)

Cycle 212 GMT 2/ 3/2024 8:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1228.76 -4 15.27 6 0 0.00 / 1049.56 6 7
2 7 1228.52 40 14.76 1959 1157 1.16 / 1050.71 7 59
3 13 1215.72 20 14.73 1956 576 1.73 / 1051.29 6 62
4 13 1187.52 20 14.69 1920 564 2.30 / 1051.85 6 64
5 13 680.36 20 14.78 1245 368 2.67 / 1052.22 6 71
6 13 83.20 20 14.96 423 127 2.79 / 1052.35 6 60
7 8 0.08 242 14.94 289 1045 3.84 / 1053.39 6 139
Average= 8.56
(KJ/cycle)

Cycle 211 GMT 26/ 2/2024 10:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1206.72 -5 15.28 7 0 0.00 / 1045.73 6 7
2 7 1206.68 40 14.77 1940 1146 1.15 / 1046.88 7 61
3 13 1200.80 20 14.74 1939 572 1.72 / 1047.45 6 63
4 13 1171.84 20 14.70 1889 555 2.27 / 1048.01 6 63
5 13 695.52 20 14.77 1265 374 2.65 / 1048.38 6 71
6 13 84.72 20 14.96 428 128 2.78 / 1048.51 6 62
7 8 0.20 242 14.94 290 1048 3.82 / 1049.56 6 153
Average= 8.60
(KJ/cycle)

Cycle 210 GMT 21/ 2/2024 12:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1235.36 -4 15.29 6 0 0.00 / 1041.90 6 7
2 7 1234.88 40 14.76 1972 1164 1.16 / 1043.06 7 61
3 13 1234.48 20 14.73 1980 583 1.75 / 1043.64 6 61
4 13 1207.88 20 14.69 1942 571 2.32 / 1044.21 6 64
5 13 661.88 20 14.78 1222 361 2.68 / 1044.57 6 71
6 13 69.76 20 14.96 405 121 2.80 / 1044.70 6 63
7 8 0.16 242 14.93 287 1037 3.84 / 1045.73 6 143
Average= 8.64
(KJ/cycle)

Cycle 209 GMT 16/ 2/2024 14:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1294.44 -3 15.29 7 0 0.00 / 1037.92 6 7
2 7 1294.28 40 14.73 2053 1210 1.21 / 1039.13 7 57
3 13 1280.12 20 14.71 2041 600 1.81 / 1039.73 6 61
4 13 1251.24 20 14.67 1996 586 2.40 / 1040.32 6 62
5 13 777.44 20 14.73 1382 407 2.80 / 1040.72 6 70
6 13 92.20 20 14.95 433 129 2.93 / 1040.85 6 62
7 8 0.04 244 14.93 286 1042 3.97 / 1041.90 6 134
Average= 8.68
(KJ/cycle)

Cycle 208 GMT 11/ 2/2024 16:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1313.56 -3 15.28 6 0 0.00 / 1033.91 6 7
2 7 1320.68 40 14.73 2095 1234 1.23 / 1035.15 7 56
3 13 1312.48 20 14.71 2082 613 1.85 / 1035.76 6 58
4 13 1248.52 20 14.68 1991 585 2.43 / 1036.34 6 61
5 13 742.12 20 14.75 1327 391 2.82 / 1036.73 6 68
6 13 108.68 20 14.95 455 136 2.96 / 1036.87 6 60
7 8 0.08 246 14.94 286 1051 4.01 / 1037.92 6 160
Average= 8.72
(KJ/cycle)

Cycle 207 GMT 6/ 2/2024 18:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1307.16 -3 15.28 6 0 0.00 / 1029.91 6 7
2 7 1307.04 40 14.72 2078 1224 1.22 / 1031.14 7 57
3 13 1297.36 20 14.71 2064 607 1.83 / 1031.74 6 61
4 13 1269.52 20 14.66 2026 594 2.43 / 1032.34 6 63
5 13 729.28 20 14.75 1316 388 2.81 / 1032.73 6 71
6 13 96.76 20 14.96 443 133 2.95 / 1032.86 6 61
7 8 0.12 242 14.94 291 1052 4.00 / 1033.91 6 134
Average= 8.76
(KJ/cycle)

Cycle 206 GMT 1/ 2/2024 20:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1331.28 -3 15.28 6 0 0.00 / 1025.84 6 7
2 7 1331.28 40 14.71 2101 1236 1.24 / 1027.07 7 58
3 13 1317.28 20 14.70 2085 613 1.85 / 1027.69 6 58
4 13 1288.88 20 14.65 2053 602 2.45 / 1028.29 6 62
5 13 814.64 20 14.72 1427 420 2.87 / 1028.71 6 66
6 13 138.24 20 14.94 501 150 3.02 / 1028.86 6 63
7 8 0.04 244 14.94 290 1057 4.08 / 1029.91 6 142
Average= 8.80
(KJ/cycle)

Cycle 205 GMT 27/ 1/2024 22: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1312.44 -3 15.28 6 0 0.00 / 1021.78 6 7
2 7 1312.40 40 14.73 2071 1220 1.22 / 1023.00 7 58
3 13 1302.48 20 14.70 2072 609 1.83 / 1023.61 6 59
4 13 1272.92 20 14.66 2033 596 2.43 / 1024.21 6 61
5 13 802.96 20 14.73 1414 417 2.84 / 1024.62 6 70
6 13 148.36 20 14.94 517 154 3.00 / 1024.78 6 64
7 8 0.00 244 14.93 290 1056 4.05 / 1025.84 6 130
Average= 8.84
(KJ/cycle)

Cycle 204 GMT 23/ 1/2024 0: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1305.48 -3 15.28 6 0 0.00 / 1017.78 6 7
2 7 1305.80 40 14.72 2069 1218 1.22 / 1019.00 7 57
3 13 1294.88 20 14.70 2061 606 1.82 / 1019.60 6 60
4 13 1264.60 20 14.66 2019 592 2.42 / 1020.20 6 61
5 13 754.48 20 14.74 1353 399 2.82 / 1020.60 6 68
6 13 84.00 20 14.96 423 127 2.94 / 1020.72 6 60
7 8 0.00 244 14.94 291 1061 4.00 / 1021.78 6 151
Average= 8.89
(KJ/cycle)

Cycle 203 GMT 18/ 1/2024 2: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1294.44 -3 15.29 7 0 0.00 / 1013.78 6 7
2 7 1294.68 40 14.74 2047 1207 1.21 / 1014.99 7 59
3 13 1283.36 20 14.72 2030 598 1.80 / 1015.59 6 58
4 13 1253.80 20 14.68 1983 582 2.39 / 1016.17 6 59
5 13 787.48 20 14.74 1380 407 2.79 / 1016.58 6 68
6 13 116.24 20 14.95 470 141 2.93 / 1016.72 6 64
7 8 0.20 244 14.94 292 1064 4.00 / 1017.78 6 141
Average= 8.93
(KJ/cycle)

Cycle 202 GMT 13/ 1/2024 3:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1287.40 -3 15.29 6 0 0.00 / 1009.68 6 7
2 7 1287.88 41 14.73 2049 1237 1.24 / 1010.92 7 58
3 13 1278.36 20 14.72 2044 602 1.84 / 1011.52 6 58
4 13 1248.60 20 14.66 1998 586 2.43 / 1012.11 6 63
5 13 878.12 20 14.71 1513 445 2.87 / 1012.55 6 65
6 13 218.88 20 14.91 620 185 3.06 / 1012.74 6 66
7 8 -0.08 242 14.94 289 1045 4.10 / 1013.78 6 132
Average= 8.97
(KJ/cycle)

Cycle 201 GMT 8/ 1/2024 5:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1293.92 -3 15.29 6 0 0.00 / 1005.76 6 7
2 7 1293.96 40 14.73 2049 1207 1.21 / 1006.97 7 58
3 13 1284.56 20 14.71 2042 601 1.81 / 1007.57 6 61
4 13 1255.36 20 14.67 1994 585 2.39 / 1008.15 6 61
5 13 676.72 20 14.77 1242 367 2.76 / 1008.52 6 70
6 13 85.60 20 14.97 423 127 2.89 / 1008.64 6 59
7 8 0.04 242 14.94 287 1038 3.92 / 1009.68 6 139
Average= 9.02
(KJ/cycle)

Cycle 200 GMT 3/ 1/2024 7:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 1313.64 -3 15.29 6 0 0.00 / 1001.77 6 7
2 7 1313.84 41 14.72 2082 1257 1.26 / 1003.03 7 58
3 13 1307.24 20 14.70 2079 611 1.87 / 1003.64 6 61
4 13 1244.16 20 14.67 1992 584 2.45 / 1004.22 6 62
5 13 697.68 20 14.76 1268 374 2.83 / 1004.60 6 71
6 13 94.72 20 14.96 437 131 2.96 / 1004.73 6 61
7 8 -0.04 240 14.94 287 1029 3.99 / 1005.76 6 129
Average= 9.06
(KJ/cycle)

Cycle 199 GMT 29/12/2023 9:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 2 14.96 439 13 0.01 / 997.68 6 7
2 3 1348.88 -2 15.29 7 0 0.00 / 997.68 6 7
3 7 1348.84 41 14.71 2126 1282 1.30 / 998.97 7 56
4 13 1332.52 20 14.69 2115 621 1.92 / 999.59 6 59
5 13 1270.36 20 14.65 2027 594 2.51 / 1000.18 6 61
6 13 822.92 20 14.72 1443 425 2.94 / 1000.61 6 69
7 13 104.56 20 14.96 452 135 3.07 / 1000.74 6 62
8 8 0.08 242 14.94 285 1030 4.10 / 1001.77 6 131
Average= 9.11
(KJ/cycle)

Cycle 198 GMT 24/12/2023 11:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 6 14.96 430 39 0.04 / 993.51 6 9
2 3 1403.80 -2 15.29 7 0 0.00 / 993.51 6 9
3 7 1403.56 40 14.69 2196 1290 1.33 / 994.80 9 54
4 13 1388.60 20 14.67 2173 638 1.97 / 995.43 6 58
5 13 1324.52 20 14.63 2080 609 2.58 / 996.04 6 58
6 13 780.56 20 14.73 1373 404 2.98 / 996.45 6 68
7 13 154.44 20 14.94 530 158 3.14 / 996.60 6 63
8 8 -0.12 246 14.94 290 1066 4.20 / 997.67 6 138
Average= 9.15
(KJ/cycle)

Cycle 197 GMT 19/12/2023 13:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 9 14.95 422 57 0.06 / 989.27 6 9
2 3 1404.64 -1 15.29 6 0 0.00 / 989.27 6 9
3 7 1404.68 41 14.69 2202 1326 1.38 / 990.59 9 55
4 13 1388.84 20 14.67 2185 641 2.02 / 991.23 6 57
5 13 1325.24 20 14.63 2103 615 2.64 / 991.85 6 61
6 13 809.52 20 14.72 1427 420 3.06 / 992.27 6 70
7 13 120.84 20 14.95 480 144 3.20 / 992.41 6 62
8 8 0.00 244 14.94 289 1054 4.26 / 993.47 6 143
Average= 9.20
(KJ/cycle)

Cycle 196 GMT 14/12/2023 15: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 14 14.96 413 86 0.09 / 985.07 6 10
2 3 1390.12 -2 15.30 7 0 0.00 / 985.07 6 10
3 7 1394.36 40 14.69 2191 1287 1.37 / 986.36 10 54
4 13 1378.08 20 14.67 2172 637 2.01 / 987.00 6 58
5 13 1316.68 20 14.63 2085 610 2.62 / 987.61 6 60
6 13 771.80 20 14.72 1380 406 3.03 / 988.01 6 70
7 13 128.88 20 14.94 493 147 3.17 / 988.16 6 63
8 8 0.32 244 14.94 288 1050 4.22 / 989.21 6 142
Average= 9.24
(KJ/cycle)

Cycle 195 GMT 9/12/2023 16:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 17 14.96 409 104 0.10 / 980.77 6 11
2 3 1446.36 -1 15.30 7 0 0.00 / 980.77 6 11
3 7 1446.20 40 14.67 2260 1326 1.43 / 982.10 11 56
4 13 1425.88 20 14.66 2236 656 2.09 / 982.76 6 58
5 13 1362.32 20 14.62 2152 629 2.72 / 983.38 6 60
6 13 782.64 20 14.72 1382 407 3.12 / 983.79 6 69
7 13 103.00 20 14.95 456 136 3.26 / 983.93 6 62
8 8 0.04 244 14.94 290 1057 4.32 / 984.99 6 140
Average= 9.29
(KJ/cycle)

Cycle 194 GMT 4/12/2023 18:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 19 14.95 413 117 0.12 / 976.44 6 12
2 3 1447.72 -1 15.30 6 0 0.00 / 976.44 6 12
3 7 1447.20 40 14.67 2259 1326 1.44 / 977.77 12 53
4 13 1429.36 20 14.66 2242 657 2.10 / 978.42 6 57
5 13 1366.44 20 14.61 2158 631 2.73 / 979.05 6 60
6 13 785.76 20 14.72 1396 411 3.14 / 979.46 6 70
7 13 121.52 20 14.95 481 144 3.29 / 979.61 6 61
8 8 0.04 246 14.94 289 1062 4.35 / 980.67 6 136
Average= 9.34
(KJ/cycle)

Cycle 193 GMT 29/11/2023 19:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 21 14.95 407 128 0.13 / 972.06 6 11
2 3 1464.52 -1 15.30 7 0 0.00 / 972.06 6 11
3 7 1464.28 40 14.67 2277 1336 1.46 / 973.39 11 53
4 13 1446.40 20 14.65 2258 662 2.13 / 974.05 6 57
5 13 1350.12 20 14.62 2135 624 2.75 / 974.68 6 61
6 13 801.40 20 14.71 1409 415 3.16 / 975.09 6 68
7 13 159.64 20 14.93 530 158 3.32 / 975.25 6 64
8 8 0.08 248 14.94 289 1071 4.39 / 976.32 6 -99
Average= 9.39
(KJ/cycle)

Cycle 192 GMT 24/11/2023 21:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 23 14.96 405 139 0.14 / 967.60 6 10
2 3 1448.88 -1 15.31 6 0 0.00 / 967.60 6 10
3 7 1478.84 40 14.67 2291 1344 1.48 / 968.94 10 54
4 13 1460.20 20 14.65 2272 666 2.15 / 969.61 6 55
5 13 1396.20 20 14.61 2188 639 2.79 / 970.25 6 59
6 13 886.32 20 14.68 1527 448 3.24 / 970.69 6 68
7 13 171.24 20 14.92 548 164 3.40 / 970.86 6 66
8 8 0.08 249 14.93 288 1071 4.47 / 971.93 6 164
Average= 9.44
(KJ/cycle)

Cycle 191 GMT 19/11/2023 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 23 14.96 404 139 0.14 / 963.14 6 10
2 7 1495.12 41 14.66 2317 1393 1.53 / 964.53 10 55
3 13 1474.72 20 14.64 2301 674 2.21 / 965.21 6 58
4 13 1376.52 20 14.60 2160 631 2.84 / 965.84 6 60
5 13 816.32 20 14.71 1430 421 3.26 / 966.26 6 70
6 13 135.48 20 14.94 499 149 3.41 / 966.41 6 62
7 8 -0.12 246 14.94 286 1051 4.46 / 967.46 6 138
Average= 9.48
(KJ/cycle)

Cycle 190 GMT 15/11/2023 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 23 14.96 412 142 0.14 / 958.46 6 10
2 7 1587.12 40 14.63 2434 1424 1.57 / 959.88 10 53
3 13 1574.12 20 14.61 2418 707 2.27 / 960.59 6 55
4 13 1508.60 20 14.56 2340 681 2.95 / 961.27 6 55
5 13 880.56 20 14.68 1514 445 3.40 / 961.72 6 67
6 13 247.32 20 14.89 652 194 3.59 / 961.91 6 67
7 13 54.76 20 14.96 376 112 3.71 / 962.02 6 58
8 8 0.08 229 14.93 286 978 4.68 / 963.00 6 131
Average= 9.53
(KJ/cycle)

Cycle 189 GMT 10/11/2023 1:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 23 14.95 414 142 0.14 / 953.78 6 11
2 7 1615.44 40 14.61 2475 1446 1.59 / 955.23 11 53
3 13 1593.20 20 14.59 2444 713 2.30 / 955.94 6 54
4 13 1424.72 20 14.57 2231 650 2.95 / 956.59 6 59
5 13 906.08 20 14.67 1552 455 3.41 / 957.05 6 68
6 13 193.20 20 14.92 580 173 3.58 / 957.22 6 65
7 13 40.72 20 14.97 360 108 3.69 / 957.33 6 57
8 8 0.00 229 14.93 289 988 4.68 / 958.32 6 151
Average= 9.58
(KJ/cycle)

Cycle 188 GMT 5/11/2023 2:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 23 14.96 409 141 0.14 / 949.27 6 10
2 7 1533.60 41 14.64 2373 1424 1.57 / 950.69 10 53
3 13 1515.36 20 14.63 2354 689 2.25 / 951.38 6 58
4 13 1384.20 20 14.60 2176 635 2.89 / 952.01 6 58
5 13 795.92 20 14.71 1403 413 3.30 / 952.43 6 67
6 13 131.96 20 14.94 495 148 3.45 / 952.58 6 62
7 8 0.16 246 14.94 290 1066 4.52 / 953.64 6 133
Average= 9.63
(KJ/cycle)

Cycle 187 GMT 31/10/2023 4: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 23 14.96 405 139 0.14 / 944.57 6 13
2 7 1570.56 41 14.63 2416 1449 1.59 / 946.02 13 54
3 13 1570.12 20 14.60 2420 707 2.30 / 946.72 6 60
4 13 1540.84 20 14.55 2370 690 2.98 / 947.41 6 57
5 13 881.84 20 14.68 1510 443 3.43 / 947.86 6 64
6 13 206.56 20 14.91 607 181 3.61 / 948.04 6 66
7 13 48.60 20 14.96 376 112 3.72 / 948.15 6 58
8 8 -0.08 227 14.93 288 976 4.70 / 949.13 6 138
Average= 9.68
(KJ/cycle)

Cycle 186 GMT 26/10/2023 5:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 23 14.95 418 144 0.14 / 940.08 6 10
2 7 1538.68 40 14.64 2372 1389 1.53 / 941.47 10 53
3 13 1523.12 20 14.62 2353 688 2.22 / 942.16 6 55
4 13 1390.36 20 14.59 2186 638 2.86 / 942.80 6 61
5 13 803.64 20 14.71 1412 415 3.27 / 943.21 6 66
6 13 102.84 20 14.95 455 136 3.41 / 943.35 6 60
7 13 33.96 20 14.97 350 105 3.51 / 943.45 6 59
8 8 0.04 227 14.93 288 976 4.49 / 944.43 6 143
Average= 9.74
(KJ/cycle)

Cycle 185 GMT 21/10/2023 6:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 23 14.96 422 145 0.15 / 935.38 6 10
2 7 1526.80 41 14.64 2360 1417 1.56 / 936.80 10 54
3 13 1526.40 20 14.62 2372 694 2.26 / 937.49 6 55
4 13 1526.40 20 14.56 2365 689 2.94 / 938.18 6 56
5 13 952.92 20 14.66 1619 475 3.42 / 938.66 6 67
6 13 258.76 20 14.89 674 201 3.62 / 938.86 6 67
7 13 28.32 20 14.97 342 102 3.72 / 938.96 6 57
8 8 -0.08 229 14.93 286 978 4.70 / 939.94 6 190
Average= 9.79
(KJ/cycle)

Cycle 184 GMT 16/10/2023 8:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 23 14.97 405 139 0.14 / 930.90 6 8
2 7 1508.28 40 14.66 2342 1373 1.51 / 932.28 8 54
3 13 1489.08 20 14.64 2319 679 2.19 / 932.95 6 59
4 13 1391.48 20 14.60 2186 638 2.83 / 933.59 6 60
5 13 799.72 20 14.72 1412 416 3.25 / 934.01 6 69
6 13 130.16 20 14.95 492 147 3.39 / 934.16 6 62
7 13 31.28 20 14.98 344 103 3.50 / 934.26 6 56
8 8 0.12 229 14.94 286 978 4.47 / 935.24 6 -99
Average= 9.84
(KJ/cycle)

Cycle 183 GMT 11/10/2023 9:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 23 14.97 398 137 0.14 / 926.36 6 9
2 7 1527.48 40 14.65 2370 1389 1.53 / 927.75 43 51
3 13 1527.04 20 14.62 2369 693 2.22 / 928.45 6 55
4 13 1497.48 20 14.57 2329 679 2.90 / 929.12 6 58
5 13 794.24 20 14.72 1400 412 3.31 / 929.54 6 69
6 13 137.72 20 14.94 505 151 3.46 / 929.69 6 64
7 13 39.64 20 14.98 358 107 3.57 / 929.79 6 57
8 8 -0.08 229 14.94 283 968 4.54 / 930.76 6 -99
Average= 9.90
(KJ/cycle)

Cycle 182 GMT 6/10/2023 10:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 23 14.96 399 137 0.14 / 921.77 6 10
2 7 1598.80 40 14.62 2458 1437 1.57 / 923.21 10 55
3 13 1589.56 20 14.60 2447 715 2.29 / 923.93 6 58
4 13 1357.52 20 14.59 2151 628 2.92 / 924.55 6 59
5 13 881.80 20 14.68 1513 444 3.36 / 925.00 6 65
6 13 165.88 20 14.93 544 162 3.52 / 925.16 6 60
7 13 32.20 20 14.98 343 103 3.63 / 925.26 6 55
8 8 0.04 227 14.94 284 963 4.59 / 926.23 6 142
Average= 9.96
(KJ/cycle)

Cycle 181 GMT 1/10/2023 11:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 23 14.96 403 139 0.14 / 917.08 6 8
2 7 1593.96 40 14.63 2450 1434 1.57 / 918.51 8 53
3 13 1593.52 20 14.60 2456 717 2.29 / 919.23 6 56
4 13 1568.60 20 14.55 2413 702 2.99 / 919.93 6 54
5 13 931.28 20 14.67 1579 463 3.46 / 920.40 6 66
6 13 156.28 20 14.94 526 157 3.61 / 920.55 6 63
7 13 27.12 20 14.98 341 102 3.71 / 920.66 6 56
8 8 0.00 229 14.94 287 982 4.70 / 921.64 6 137
Average= 10.02
(KJ/cycle)

Cycle 180 GMT 26/ 9/2023 13:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 23 14.97 403 139 0.14 / 912.32 6 8
2 7 1689.52 40 14.59 2564 1496 1.64 / 913.82 8 50
3 13 1689.04 20 14.56 2565 747 2.38 / 914.57 6 52
4 13 1522.32 20 14.54 2353 684 3.07 / 915.25 6 57
5 13 870.84 20 14.68 1509 443 3.51 / 915.69 6 67
6 13 172.92 20 14.93 550 164 3.67 / 915.86 6 63
7 13 34.72 20 14.97 348 104 3.78 / 915.96 6 55
8 8 0.00 231 14.94 284 980 4.76 / 916.94 6 218
Average= 10.08
(KJ/cycle)

Cycle 179 GMT 21/ 9/2023 14: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 23 14.97 403 139 0.14 / 907.74 6 7
2 7 1565.24 41 14.64 2411 1447 1.59 / 909.19 39 55
3 13 1546.44 20 14.61 2396 700 2.29 / 909.89 6 54
4 13 1448.16 20 14.58 2262 660 2.95 / 910.55 6 58
5 13 786.04 20 14.72 1390 409 3.35 / 910.96 6 69
6 13 120.80 20 14.96 475 142 3.50 / 911.10 6 58
7 13 29.32 20 14.98 343 103 3.60 / 911.20 6 56
8 8 0.08 229 14.94 286 978 4.58 / 912.18 6 -99
Average= 10.14
(KJ/cycle)

Cycle 178 GMT 16/ 9/2023 15:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 23 14.97 402 138 0.14 / 902.88 6 8
2 7 1527.00 40 14.65 2358 1382 1.52 / 904.26 8 53
3 13 1526.56 20 14.62 2365 692 2.21 / 904.95 6 56
4 13 1526.60 20 14.57 2360 688 2.90 / 905.64 6 57
5 13 1500.64 20 14.52 2323 675 3.57 / 906.31 6 59
6 13 278.80 20 14.89 704 210 3.78 / 906.52 6 68
7 13 40.28 20 14.98 357 107 3.89 / 906.63 6 60
8 8 0.04 231 14.94 283 977 4.87 / 907.60 6 173
Average= 10.20
(KJ/cycle)

Cycle 177 GMT 11/ 9/2023 16:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 23 14.97 394 136 0.14 / 898.35 6 8
2 7 1524.52 41 14.65 2355 1415 1.55 / 899.76 8 53
3 13 1507.56 20 14.63 2341 685 2.24 / 900.45 6 58
4 13 1409.08 20 14.60 2216 647 2.88 / 901.09 6 58
5 13 826.88 20 14.71 1438 423 3.31 / 901.52 6 66
6 13 147.04 20 14.94 516 154 3.46 / 901.67 6 63
7 13 21.56 20 14.99 332 100 3.56 / 901.77 6 55
8 8 0.00 227 14.94 285 967 4.53 / 902.74 6 158
Average= 10.26
(KJ/cycle)

Cycle 176 GMT 6/ 9/2023 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 23 14.97 405 139 0.14 / 893.65 6 8
2 7 1681.52 40 14.59 2561 1495 1.63 / 895.14 8 51
3 13 1658.60 20 14.57 2542 741 2.37 / 895.88 6 54
4 13 1385.00 20 14.57 2181 636 3.01 / 896.52 6 59
5 13 871.00 20 14.68 1504 442 3.45 / 896.96 6 68
6 13 168.28 20 14.93 548 164 3.62 / 897.12 6 62
7 13 29.40 20 14.98 347 104 3.72 / 897.23 6 59
8 8 -0.04 229 14.94 288 985 4.70 / 898.21 6 143
Average= 10.32
(KJ/cycle)

Cycle 175 GMT 1/ 9/2023 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 23 14.97 395 136 0.14 / 888.92 6 7
2 7 1624.08 40 14.63 2484 1454 1.59 / 890.37 7 52
3 13 1614.84 20 14.60 2484 725 2.31 / 891.09 6 54
4 13 1480.68 20 14.57 2311 673 2.99 / 891.77 6 58
5 13 879.16 20 14.69 1511 444 3.43 / 892.21 6 66
6 13 252.24 20 14.90 666 198 3.63 / 892.41 6 68
7 13 28.72 20 14.98 344 103 3.73 / 892.51 6 59
8 8 0.08 231 14.94 288 994 4.73 / 893.51 6 -99
Average= 10.39
(KJ/cycle)

Cycle 174 GMT 27/ 8/2023 20:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 23 14.97 404 139 0.14 / 883.70 6 7
2 7 1944.64 40 14.50 2907 1686 1.83 / 885.39 7 46
3 13 1918.12 20 14.49 2874 833 2.66 / 886.22 6 48
4 13 1570.28 20 14.49 2419 701 3.36 / 886.92 6 57
5 13 1022.60 20 14.61 1711 500 3.86 / 887.42 6 65
6 13 354.72 20 14.84 809 240 4.10 / 887.66 6 69
7 13 42.56 20 14.96 365 109 4.21 / 887.77 6 59
8 8 0.00 233 14.93 289 1005 5.21 / 888.78 6 135
Average= 10.46
(KJ/cycle)

Cycle 173 GMT 22/ 8/2023 20:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 23 14.98 403 139 0.14 / 878.86 6 7
2 7 1751.84 41 14.57 2652 1584 1.72 / 880.45 7 49
3 13 1728.36 20 14.55 2628 765 2.49 / 881.21 6 51
4 13 1461.88 20 14.55 2281 664 3.15 / 881.88 6 58
5 13 837.84 20 14.69 1458 428 3.58 / 882.30 6 69
6 13 177.96 20 14.93 561 168 3.75 / 882.47 6 66
7 13 38.12 20 14.98 358 107 3.85 / 882.58 6 57
8 8 0.16 231 14.94 286 987 4.84 / 883.57 6 -99
Average= 10.52
(KJ/cycle)

Cycle 172 GMT 17/ 8/2023 21:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 23 14.98 400 138 0.14 / 873.66 6 8
2 7 1918.24 40 14.52 2860 1661 1.80 / 875.32 44 45
3 13 1890.92 20 14.49 2832 821 2.62 / 876.14 6 48
4 13 1616.56 20 14.49 2488 721 3.34 / 876.87 6 54
5 13 1058.32 20 14.61 1765 516 3.86 / 877.38 6 66
6 13 282.96 20 14.88 710 211 4.07 / 877.59 6 68
7 13 51.44 20 14.96 382 114 4.18 / 877.71 6 60
8 13 15.00 20 14.97 323 97 4.28 / 877.80 6 57
9 8 0.00 214 14.94 288 921 5.20 / 878.72 6 212
Average= 10.59
(KJ/cycle)

Cycle 171 GMT 12/ 8/2023 21:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 23 14.97 405 139 0.14 / 868.34 6 7
2 7 2013.52 40 14.48 2994 1734 1.87 / 870.07 7 42
3 13 1986.04 20 14.46 2959 856 2.73 / 870.93 6 47
4 13 1603.60 20 14.48 2461 713 3.44 / 871.64 6 51
5 13 1017.68 20 14.61 1703 498 3.94 / 872.14 6 66
6 13 385.24 20 14.83 853 253 4.19 / 872.39 6 70
7 13 64.72 20 14.96 401 120 4.31 / 872.51 6 61
8 13 15.92 20 14.97 325 97 4.41 / 872.61 6 56
9 8 0.08 214 14.93 287 917 5.33 / 873.52 6 176
Average= 10.65
(KJ/cycle)

Cycle 170 GMT 7/ 8/2023 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 23 14.98 402 139 0.14 / 862.96 6 8
2 7 2008.68 40 14.48 2986 1729 1.87 / 864.69 8 46
3 13 1981.80 20 14.47 2953 855 2.72 / 865.55 6 50
4 13 1703.44 20 14.46 2597 751 3.47 / 866.30 6 54
5 13 1012.44 20 14.62 1695 496 3.97 / 866.79 6 66
6 13 456.96 20 14.81 944 280 4.25 / 867.07 6 69
7 13 57.12 20 14.96 384 115 4.36 / 867.19 6 60
8 13 16.76 20 14.97 325 97 4.46 / 867.28 6 55
9 8 0.04 214 14.93 286 914 5.37 / 868.20 6 135
Average= 10.72
(KJ/cycle)

Cycle 169 GMT 2/ 8/2023 22:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 23 14.97 407 140 0.14 / 857.60 6 8
2 7 2011.40 40 14.49 2996 1736 1.88 / 859.34 8 45
3 13 1984.92 20 14.46 2963 857 2.73 / 860.20 6 46
4 13 1634.16 20 14.48 2512 727 3.46 / 860.92 6 55
5 13 1038.56 20 14.61 1728 505 3.97 / 861.43 6 66
6 13 406.48 20 14.83 877 260 4.23 / 861.69 6 70
7 13 50.08 20 14.97 374 112 4.34 / 861.80 6 60
8 13 15.00 20 14.97 325 97 4.44 / 861.90 6 57
9 8 0.08 216 14.93 287 926 5.36 / 862.82 6 -99
Average= 10.79
(KJ/cycle)

Cycle 168 GMT 28/ 7/2023 23:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 23 14.99 395 136 0.14 / 852.27 6 8
2 7 2014.16 40 14.48 2994 1734 1.87 / 854.00 8 45
3 13 1987.76 20 14.46 2977 861 2.73 / 854.86 6 48
4 13 1637.80 20 14.47 2518 729 3.46 / 855.59 6 53
5 13 1045.44 20 14.61 1741 509 3.97 / 856.10 6 64
6 13 341.36 20 14.86 794 236 4.20 / 856.34 6 70
7 13 34.36 20 14.97 357 107 4.31 / 856.44 6 58
8 8 0.00 235 14.94 290 1018 5.33 / 857.46 6 -99
Average= 10.85
(KJ/cycle)

Cycle 167 GMT 23/ 7/2023 23:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 23 14.97 402 138 0.14 / 846.95 6 8
2 7 2016.04 40 14.49 3001 1739 1.88 / 848.69 8 45
3 13 1989.52 20 14.46 2975 860 2.74 / 849.55 6 47
4 13 1676.64 20 14.47 2560 741 3.48 / 850.29 6 55
5 13 1038.28 20 14.61 1731 506 3.98 / 850.80 6 64
6 13 309.72 20 14.88 746 222 4.21 / 851.02 6 67
7 13 38.20 20 14.98 356 107 4.31 / 851.13 6 57
8 8 0.00 233 14.94 289 1006 5.32 / 852.13 6 144
Average= 10.92
(KJ/cycle)

Cycle 166 GMT 19/ 7/2023 0:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 23 14.99 411 142 0.14 / 841.63 6 7
2 7 2014.68 40 14.48 2997 1736 1.88 / 843.37 7 45
3 13 1987.96 20 14.46 2974 860 2.74 / 844.23 6 49
4 13 1607.56 20 14.48 2472 716 3.45 / 844.94 6 56
5 13 1019.28 20 14.62 1704 498 3.95 / 845.44 6 64
6 13 387.44 20 14.84 846 251 4.20 / 845.69 6 67
7 13 42.28 20 14.98 362 108 4.31 / 845.80 6 55
8 8 0.08 235 14.94 288 1011 5.32 / 846.81 6 -99
Average= 11.00
(KJ/cycle)

Cycle 165 GMT 14/ 7/2023 1: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 23 14.98 404 139 0.14 / 836.29 6 7
2 7 2015.12 40 14.49 3002 1740 1.88 / 838.03 7 46
3 13 1986.64 20 14.47 2974 861 2.74 / 838.89 6 45
4 13 1667.56 20 14.47 2557 740 3.48 / 839.63 6 54
5 13 1014.28 20 14.62 1702 498 3.98 / 840.13 6 62
6 13 357.88 20 14.86 811 241 4.22 / 840.37 6 68
7 13 53.56 20 14.97 379 113 4.33 / 840.49 6 57
8 8 4.12 235 14.95 286 1005 5.34 / 841.49 6 -99
Average= 11.07
(KJ/cycle)

Cycle 164 GMT 9/ 7/2023 1:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 23 14.99 396 137 0.14 / 830.93 6 7
2 7 2016.16 40 14.49 3000 1739 1.88 / 832.67 7 46
3 13 1989.44 20 14.46 2968 858 2.73 / 833.53 6 48
4 13 1673.68 20 14.47 2558 740 3.47 / 834.27 6 54
5 13 1044.12 20 14.61 1736 507 3.98 / 834.78 6 67
6 13 344.56 20 14.86 789 234 4.22 / 835.01 6 67
7 13 67.64 20 14.96 399 119 4.34 / 835.13 6 58
8 13 16.88 20 14.98 326 98 4.43 / 835.23 6 57
9 8 3.80 214 14.94 289 924 5.36 / 836.15 6 139
Average= 11.15
(KJ/cycle)

Cycle 163 GMT 4/ 7/2023 1:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 23 14.97 407 140 0.14 / 825.63 6 10
2 7 2003.96 40 14.50 2986 1732 1.87 / 827.36 10 43
3 13 1977.56 20 14.47 2954 855 2.73 / 828.21 6 47
4 13 1662.08 20 14.48 2546 737 3.46 / 828.95 6 54
5 13 999.12 20 14.63 1681 492 3.96 / 829.44 6 66
6 13 345.00 20 14.86 795 236 4.19 / 829.68 6 69
7 13 41.24 20 14.98 363 109 4.30 / 829.79 6 55
8 8 0.48 235 14.95 287 1008 5.31 / 830.80 6 -99
Average= 11.23
(KJ/cycle)

Cycle 162 GMT 29/ 6/2023 2:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 23 14.98 406 140 0.14 / 820.29 6 10
2 7 2008.56 40 14.49 2992 1734 1.87 / 822.02 10 41
3 13 1981.48 20 14.47 2954 855 2.73 / 822.88 6 48
4 13 1669.36 20 14.47 2557 740 3.47 / 823.62 6 52
5 13 1005.00 20 14.63 1681 492 3.96 / 824.11 6 62
6 13 377.92 20 14.85 842 250 4.21 / 824.36 6 73
7 13 33.08 20 14.98 354 106 4.32 / 824.47 6 60
8 8 0.04 233 14.94 293 1020 5.34 / 825.49 6 143
Average= 11.31
(KJ/cycle)

Cycle 161 GMT 24/ 6/2023 2:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 23 14.98 409 141 0.14 / 815.05 6 8
2 7 2014.52 40 14.49 2997 1737 1.88 / 816.79 8 46
3 13 1986.40 20 14.46 2966 858 2.74 / 817.64 6 48
4 13 1563.40 20 14.50 2419 702 3.44 / 818.34 6 55
5 13 941.00 20 14.65 1597 468 3.91 / 818.81 6 66
6 13 286.12 20 14.89 716 213 4.12 / 819.03 6 68
7 13 28.00 20 14.99 348 104 4.22 / 819.13 6 57
8 8 0.12 233 14.95 293 1021 5.24 / 820.15 6 -99
Average= 11.39
(KJ/cycle)

Cycle 160 GMT 19/ 6/2023 3:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 23 14.98 409 141 0.14 / 809.70 6 9
2 7 2016.16 40 14.49 3001 1739 1.88 / 811.44 9 43
3 13 1990.32 20 14.46 2964 857 2.74 / 812.30 6 47
4 13 1646.92 20 14.48 2521 730 3.47 / 813.03 6 54
5 13 1019.12 20 14.62 1710 500 3.97 / 813.53 6 66
6 13 416.80 20 14.83 896 266 4.23 / 813.79 6 72
7 13 31.48 20 14.98 351 105 4.34 / 813.90 6 58
8 8 -0.04 233 14.95 290 1010 5.35 / 814.91 6 142
Average= 11.48
(KJ/cycle)

Cycle 159 GMT 14/ 6/2023 3:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 23 14.98 417 144 0.14 / 804.41 6 8
2 7 2006.08 40 14.50 2987 1732 1.88 / 806.14 8 43
3 13 1978.72 20 14.47 2957 856 2.73 / 807.00 6 45
4 13 1594.64 20 14.50 2466 715 3.45 / 807.71 6 55
5 13 1002.40 20 14.63 1683 492 3.94 / 808.20 6 67
6 13 334.64 20 14.87 779 232 4.17 / 808.44 6 69
7 13 34.08 20 14.99 354 106 4.28 / 808.54 6 58
8 8 -0.12 233 14.95 292 1017 5.29 / 809.56 6 160
Average= 11.57
(KJ/cycle)

Cycle 158 GMT 9/ 6/2023 4:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 23 14.98 409 141 0.14 / 799.07 6 10
2 7 2006.56 41 14.49 2992 1778 1.92 / 800.85 10 42
3 13 1978.56 20 14.47 2952 854 2.77 / 801.70 6 47
4 13 1627.32 20 14.49 2502 725 3.50 / 802.43 6 54
5 13 1056.00 20 14.61 1761 515 4.01 / 802.94 6 65
6 13 281.40 20 14.89 706 210 4.22 / 803.15 6 69
7 13 46.24 20 14.98 373 112 4.33 / 803.26 6 57
8 8 0.04 231 14.95 290 1002 5.34 / 804.26 6 137
Average= 11.66
(KJ/cycle)

Cycle 157 GMT 4/ 6/2023 5: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 23 14.98 407 140 0.14 / 793.74 6 10
2 7 2014.48 40 14.49 3004 1741 1.88 / 795.48 10 43
3 13 1987.64 20 14.47 2970 860 2.74 / 796.34 6 46
4 13 1568.52 20 14.50 2433 706 3.45 / 797.05 6 55
5 13 1023.08 20 14.63 1718 503 3.95 / 797.55 6 67
6 13 415.44 20 14.84 888 264 4.21 / 797.81 6 69
7 13 34.04 20 14.99 352 106 4.32 / 797.92 6 57
8 8 0.00 233 14.95 290 1010 5.33 / 798.93 6 140
Average= 11.75
(KJ/cycle)

Cycle 156 GMT 30/ 5/2023 5:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 23 14.98 410 141 0.14 / 788.54 6 10
2 7 2006.20 40 14.49 2988 1732 1.87 / 790.27 10 46
3 13 1978.36 20 14.48 2944 853 2.73 / 791.12 6 48
4 13 1529.08 20 14.52 2376 690 3.42 / 791.81 6 56
5 13 976.68 20 14.64 1651 483 3.90 / 792.29 6 65
6 13 276.28 20 14.90 698 208 4.11 / 792.50 6 67
7 13 27.48 20 14.99 341 102 4.21 / 792.61 6 55
8 8 0.04 231 14.95 288 995 5.20 / 793.60 6 150
Average= 11.84
(KJ/cycle)

Cycle 155 GMT 25/ 5/2023 6:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 23 14.98 404 139 0.14 / 783.13 6 9
2 7 2016.80 41 14.49 3012 1789 1.93 / 784.92 9 44
3 13 1990.72 20 14.46 2980 862 2.79 / 785.78 6 47
4 13 1609.00 20 14.49 2488 721 3.51 / 786.50 6 54
5 13 1075.80 20 14.61 1778 520 4.03 / 787.02 6 66
6 13 402.64 20 14.84 875 260 4.29 / 787.28 6 71
7 13 43.48 20 14.98 371 111 4.40 / 787.39 6 60
8 8 0.04 231 14.95 291 1005 5.41 / 788.40 6 133
Average= 11.95
(KJ/cycle)

Cycle 154 GMT 20/ 5/2023 6:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 23 14.99 405 140 0.14 / 777.80 6 10
2 7 2010.64 41 14.49 2994 1779 1.92 / 779.58 10 44
3 13 1983.16 20 14.46 2959 856 2.77 / 780.43 6 47
4 13 1595.28 20 14.50 2462 714 3.49 / 781.15 6 54
5 13 970.28 20 14.65 1646 482 3.97 / 781.63 6 66
6 13 382.56 20 14.85 845 251 4.22 / 781.88 6 70
7 13 32.40 20 14.99 348 104 4.33 / 781.98 6 59
8 8 0.04 231 14.95 291 1005 5.33 / 782.99 6 143
Average= 12.05
(KJ/cycle)

Cycle 153 GMT 15/ 5/2023 7:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 23 14.99 407 140 0.14 / 772.50 6 11
2 7 2014.44 40 14.50 2998 1739 1.88 / 774.24 11 44
3 13 1987.68 20 14.48 2963 858 2.74 / 775.10 6 48
4 13 1566.48 20 14.50 2430 705 3.44 / 775.81 6 55
5 13 1024.76 20 14.63 1718 503 3.94 / 776.31 6 67
6 13 363.76 20 14.87 818 243 4.19 / 776.55 6 69
7 13 47.56 20 14.98 369 111 4.30 / 776.66 6 57
8 8 0.04 233 14.96 286 997 5.30 / 777.66 6 205
Average= 12.15
(KJ/cycle)

Cycle 152 GMT 10/ 5/2023 7:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 23 14.98 410 141 0.14 / 767.25 6 11
2 7 2003.80 40 14.50 2981 1729 1.87 / 768.98 11 46
3 13 1976.68 20 14.48 2956 856 2.73 / 769.83 6 46
4 13 1583.56 20 14.50 2440 708 3.43 / 770.54 6 55
5 13 1033.60 20 14.63 1724 504 3.94 / 771.05 6 67
6 13 319.20 20 14.89 753 224 4.16 / 771.27 6 68
7 13 25.04 20 15.00 336 101 4.26 / 771.37 6 56
8 8 0.08 231 14.96 287 992 5.26 / 772.36 6 139
Average= 12.26
(KJ/cycle)

Cycle 151 GMT 5/ 5/2023 8:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 23 14.98 410 141 0.14 / 761.94 6 12
2 7 2014.20 40 14.50 3003 1742 1.88 / 763.68 12 41
3 13 1988.00 20 14.48 2966 859 2.74 / 764.54 6 44
4 13 1635.28 20 14.49 2505 726 3.47 / 765.27 6 54
5 13 1032.64 20 14.63 1721 504 3.97 / 765.77 6 67
6 13 329.00 20 14.88 770 229 4.20 / 766.00 6 71
7 13 29.68 20 14.99 345 103 4.30 / 766.10 6 59
8 8 0.08 231 14.96 291 1006 5.31 / 767.11 6 130
Average= 12.37
(KJ/cycle)

Cycle 150 GMT 30/ 4/2023 9: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 23 14.99 407 140 0.14 / 756.70 6 12
2 7 2012.92 41 14.49 2997 1780 1.92 / 758.48 12 45
3 13 1985.28 20 14.47 2967 859 2.78 / 759.34 6 48
4 13 1526.24 20 14.52 2376 690 3.47 / 760.03 6 57
5 13 975.72 20 14.65 1645 482 3.95 / 760.51 6 65
6 13 213.56 20 14.93 608 182 4.13 / 760.70 6 67
7 13 17.28 20 15.00 325 97 4.23 / 760.79 6 56
8 8 -0.04 231 14.96 291 1006 5.24 / 761.80 6 134
Average= 12.49
(KJ/cycle)

Cycle 149 GMT 25/ 4/2023 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 23 14.98 411 142 0.14 / 751.44 6 13
2 7 2013.00 40 14.50 2992 1735 1.88 / 753.17 13 45
3 13 1987.08 20 14.48 2958 857 2.73 / 754.03 6 46
4 13 1604.88 20 14.50 2466 715 3.45 / 754.74 6 57
5 13 946.72 20 14.67 1598 469 3.92 / 755.21 6 66
6 13 367.08 20 14.87 824 245 4.16 / 755.46 6 68
7 13 25.84 20 15.00 341 102 4.26 / 755.56 6 55
8 8 0.00 231 14.96 290 1002 5.27 / 756.56 6 132
Average= 12.61
(KJ/cycle)

Cycle 148 GMT 20/ 4/2023 9:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 23 14.98 407 140 0.14 / 746.25 6 14
2 7 2009.52 40 14.50 2994 1737 1.88 / 747.98 14 46
3 13 1980.04 20 14.48 2951 855 2.73 / 748.84 6 48
4 13 1477.32 20 14.54 2301 669 3.40 / 749.51 6 58
5 13 1031.96 20 14.63 1713 501 3.90 / 750.01 6 65
6 13 254.04 20 14.92 666 199 4.10 / 750.21 6 67
7 13 14.76 20 15.01 324 97 4.20 / 750.30 6 55
8 8 0.08 231 14.96 287 992 5.19 / 751.30 6 159
Average= 12.73
(KJ/cycle)

Cycle 147 GMT 15/ 4/2023 10:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 23 14.98 417 144 0.14 / 740.90 6 13
2 7 2011.80 40 14.50 2994 1737 1.88 / 742.64 13 45
3 13 1981.28 20 14.48 2960 857 2.74 / 743.50 6 49
4 13 1699.16 20 14.48 2597 752 3.49 / 744.25 6 52
5 13 1026.76 20 14.64 1718 503 3.99 / 744.75 6 66
6 13 359.76 20 14.87 813 242 4.23 / 744.99 6 69
7 13 26.64 20 15.00 342 103 4.34 / 745.09 6 55
8 8 -0.16 233 14.96 290 1011 5.35 / 746.11 6 195
Average= 12.86
(KJ/cycle)

Cycle 146 GMT 10/ 4/2023 11: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 23 14.98 411 142 0.14 / 735.89 6 11
2 7 1817.80 40 14.57 2740 1597 1.74 / 737.48 11 49
3 13 1791.40 20 14.55 2705 787 2.53 / 738.27 6 51
4 13 1513.12 20 14.55 2354 685 3.21 / 738.96 6 57
5 13 990.36 20 14.66 1662 487 3.70 / 739.44 6 65
6 13 307.20 20 14.90 740 221 3.92 / 739.66 6 69
7 13 15.56 20 15.00 326 98 4.02 / 739.76 6 58
8 8 0.16 229 14.96 291 997 5.01 / 740.76 6 132
Average= 13.00
(KJ/cycle)

Cycle 145 GMT 5/ 4/2023 11:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 23 14.98 424 146 0.15 / 731.28 6 13
2 7 1621.60 40 14.64 2480 1452 1.60 / 732.73 13 51
3 13 1599.24 20 14.62 2459 719 2.32 / 733.45 6 55
4 13 1395.16 20 14.62 2199 643 2.96 / 734.10 6 60
5 13 804.92 20 14.74 1423 420 3.38 / 734.51 6 67
6 13 133.76 20 14.98 498 149 3.53 / 734.66 6 63
7 13 15.48 20 15.02 323 97 3.63 / 734.76 6 57
8 8 -0.08 225 14.97 292 984 4.61 / 735.74 6 142
Average= 13.14
(KJ/cycle)

Cycle 144 GMT 31/ 3/2023 13: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 23 14.99 421 145 0.15 / 726.21 6 13
2 7 1859.80 40 14.56 2804 1633 1.78 / 727.85 13 46
3 13 1836.96 20 14.53 2764 803 2.58 / 728.65 6 50
4 13 1514.52 20 14.55 2352 684 3.27 / 729.33 6 57
5 13 993.80 20 14.66 1675 491 3.76 / 729.82 6 64
6 13 313.44 20 14.90 748 223 3.98 / 730.05 6 69
7 8 0.08 248 14.97 293 1088 5.07 / 731.13 6 136
Average= 13.29
(KJ/cycle)

Cycle 143 GMT 26/ 3/2023 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 23 14.98 408 141 0.14 / 720.82 6 14
2 7 2010.16 40 14.50 3001 1741 1.88 / 722.56 14 45
3 13 1985.04 20 14.47 2964 858 2.74 / 723.42 6 47
4 13 1922.84 20 14.43 2881 831 3.57 / 724.25 6 49
5 13 1012.48 20 14.66 1689 495 4.07 / 724.74 6 63
6 13 342.80 20 14.89 793 236 4.30 / 724.98 6 69
7 8 0.00 250 14.97 291 1089 5.39 / 726.07 6 131
Average= 13.45
(KJ/cycle)

Cycle 142 GMT 21/ 3/2023 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 23 14.98 408 141 0.14 / 715.93 6 13
2 7 1719.44 40 14.62 2619 1532 1.67 / 717.46 13 50
3 13 1696.84 20 14.59 2592 756 2.43 / 718.22 6 53
4 13 1598.76 20 14.56 2461 717 3.15 / 718.93 6 56
5 13 868.24 20 14.72 1506 443 3.59 / 719.38 6 66
6 13 276.92 20 14.92 702 209 3.80 / 719.59 6 70
7 8 0.12 248 14.97 294 1091 4.89 / 720.68 6 142
Average= 13.60
(KJ/cycle)

Cycle 141 GMT 16/ 3/2023 15:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 23 14.97 412 142 0.14 / 710.56 6 11
2 7 2011.64 41 14.50 2987 1776 1.92 / 712.34 11 45
3 13 1984.20 20 14.48 2955 856 2.77 / 713.19 6 47
4 13 1550.68 20 14.53 2401 698 3.47 / 713.89 6 56
5 13 1063.88 20 14.63 1766 517 3.99 / 714.41 6 64
6 13 454.76 20 14.83 944 280 4.27 / 714.69 6 73
7 8 0.16 250 14.96 294 1100 5.37 / 715.79 6 137
Average= 13.77
(KJ/cycle)

Cycle 140 GMT 11/ 3/2023 16:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 23 14.99 409 141 0.14 / 705.23 6 13
2 7 2008.04 40 14.51 2986 1733 1.87 / 706.96 13 45
3 13 1981.08 20 14.49 2961 858 2.73 / 707.82 6 46
4 13 1531.28 20 14.54 2372 690 3.42 / 708.51 6 56
5 13 1150.56 20 14.60 1875 547 3.97 / 709.06 6 65
6 13 381.12 20 14.86 847 252 4.22 / 709.31 6 75
7 13 15.88 20 15.00 331 99 4.32 / 709.41 6 61
8 8 -0.04 231 14.95 293 1012 5.33 / 710.42 6 137
Average= 13.93
(KJ/cycle)

Cycle 139 GMT 6/ 3/2023 16:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 23 14.98 412 142 0.14 / 700.00 6 12
2 7 2016.56 40 14.51 3003 1743 1.88 / 701.74 12 46
3 13 1990.04 20 14.48 2974 861 2.75 / 702.60 6 47
4 13 1502.08 20 14.54 2336 679 3.43 / 703.28 6 54
5 13 885.92 20 14.69 1527 449 3.87 / 703.73 6 67
6 13 441.48 20 14.84 921 273 4.15 / 704.00 6 70
7 8 0.12 250 14.97 290 1085 5.23 / 705.09 6 137
Average= 14.10
(KJ/cycle)

Cycle 138 GMT 1/ 3/2023 17:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 23 14.98 412 142 0.14 / 694.64 6 13
2 7 2014.20 40 14.51 2998 1740 1.88 / 696.38 13 43
3 13 1985.72 20 14.49 2966 860 2.74 / 697.24 6 46
4 13 1660.20 20 14.50 2541 737 3.48 / 697.98 6 55
5 13 988.12 20 14.66 1669 489 3.97 / 698.47 6 66
6 13 425.60 20 14.85 903 268 4.24 / 698.74 6 71
7 13 14.28 20 15.01 325 98 4.33 / 698.83 6 59
8 8 -0.08 233 14.96 293 1021 5.35 / 699.85 6 140
Average= 14.28
(KJ/cycle)

Cycle 137 GMT 24/ 2/2023 18: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 23 14.98 425 146 0.15 / 689.40 6 13
2 7 2008.92 40 14.51 2984 1732 1.88 / 691.13 13 44
3 13 1981.96 20 14.49 2951 855 2.73 / 691.98 6 47
4 13 1552.64 20 14.53 2409 700 3.43 / 692.68 6 55
5 13 931.12 20 14.68 1588 466 3.90 / 693.15 6 65
6 13 336.88 20 14.89 790 235 4.14 / 693.38 6 71
7 8 0.08 250 14.97 298 1115 5.25 / 694.50 6 134
Average= 14.47
(KJ/cycle)

Cycle 136 GMT 19/ 2/2023 18:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 23 14.99 419 144 0.14 / 684.15 6 13
2 7 2013.40 40 14.52 2996 1740 1.88 / 685.89 13 45
3 13 1985.72 20 14.49 2961 858 2.74 / 686.75 6 47
4 13 1451.24 20 14.56 2271 661 3.40 / 687.41 6 58
5 13 979.72 20 14.66 1647 483 3.89 / 687.89 6 66
6 13 410.12 20 14.86 882 262 4.15 / 688.16 6 72
7 8 0.12 250 14.97 292 1093 5.24 / 689.25 6 131
Average= 14.66
(KJ/cycle)

Cycle 135 GMT 14/ 2/2023 19:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 23 14.99 430 148 0.15 / 678.90 6 14
2 7 2009.92 40 14.52 2997 1741 1.89 / 680.65 14 43
3 13 1983.24 20 14.49 2955 856 2.75 / 681.50 6 47
4 13 1532.84 20 14.54 2382 693 3.44 / 682.19 6 55
5 13 980.68 20 14.67 1651 484 3.92 / 682.68 6 65
6 13 316.20 20 14.90 758 226 4.15 / 682.90 6 71
7 13 20.24 20 15.01 333 100 4.25 / 683.00 6 58
8 8 -0.08 231 14.97 290 1003 5.25 / 684.01 6 130
Average= 14.87
(KJ/cycle)

Cycle 134 GMT 9/ 2/2023 19:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 23 15.00 423 146 0.15 / 673.57 6 13
2 7 2011.88 40 14.52 3004 1745 1.89 / 675.31 13 44
3 13 1981.84 20 14.49 2963 859 2.75 / 676.17 6 46
4 13 1699.36 20 14.50 2602 755 3.50 / 676.92 6 53
5 13 993.40 20 14.67 1669 490 3.99 / 677.41 6 63
6 13 344.72 20 14.89 793 236 4.23 / 677.65 6 71
7 8 -0.08 253 14.98 292 1107 5.34 / 678.76 6 157
Average= 15.08
(KJ/cycle)

Cycle 133 GMT 4/ 2/2023 20:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 23 14.99 434 150 0.15 / 668.36 6 11
2 7 2007.96 40 14.51 2984 1732 1.88 / 670.09 11 46
3 13 1979.80 20 14.49 2957 857 2.74 / 670.95 6 45
4 13 1518.92 20 14.54 2355 685 3.42 / 671.63 6 56
5 13 969.04 20 14.68 1625 477 3.90 / 672.11 6 66
6 13 271.36 20 14.92 698 208 4.11 / 672.32 6 70
7 8 0.16 250 14.98 294 1101 5.21 / 673.42 6 149
Average= 15.31
(KJ/cycle)

Cycle 132 GMT 30/ 1/2023 20:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 23 14.99 430 148 0.15 / 663.00 6 13
2 7 2010.40 41 14.51 2998 1784 1.93 / 664.79 13 44
3 13 1982.20 20 14.49 2963 859 2.79 / 665.65 6 46
4 13 1626.72 20 14.51 2501 726 3.52 / 666.37 6 56
5 13 931.44 20 14.69 1585 466 3.98 / 666.84 6 67
6 13 445.24 20 14.85 933 277 4.26 / 667.11 6 73
7 8 0.12 250 14.97 293 1097 5.36 / 668.21 6 134
Average= 15.54
(KJ/cycle)

Cycle 131 GMT 25/ 1/2023 21:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 23 14.99 424 146 0.15 / 657.74 6 13
2 7 2015.16 40 14.51 3006 1745 1.89 / 659.49 13 44
3 13 1986.12 20 14.49 2960 858 2.75 / 660.34 6 48
4 13 1601.20 20 14.52 2475 719 3.47 / 661.06 6 55
5 13 940.00 20 14.68 1603 471 3.94 / 661.53 6 67
6 13 207.44 20 14.95 610 182 4.12 / 661.72 6 70
7 13 55.88 20 15.00 392 118 4.24 / 661.83 6 63
8 8 0.00 229 14.97 298 1022 5.26 / 662.85 6 138
Average= 15.78
(KJ/cycle)

Cycle 130 GMT 20/ 1/2023 21:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 23 14.99 419 144 0.14 / 652.43 6 12
2 7 2010.76 40 14.52 2995 1739 1.88 / 654.17 12 45
3 13 1980.76 20 14.49 2962 858 2.74 / 655.03 6 46
4 13 1584.56 20 14.53 2447 711 3.45 / 655.74 6 54
5 13 993.36 20 14.67 1682 493 3.95 / 656.23 6 67
6 13 327.20 20 14.90 773 230 4.18 / 656.46 6 72
7 13 26.00 20 15.01 347 104 4.28 / 656.57 6 62
8 8 0.04 232 14.97 296 1028 5.31 / 657.60 6 175
Average= 16.04
(KJ/cycle)

Cycle 129 GMT 15/ 1/2023 22:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 23 14.98 428 147 0.15 / 647.22 6 14
2 7 2009.12 40 14.52 2992 1738 1.89 / 648.95 14 45
3 13 1981.32 20 14.50 2962 859 2.74 / 649.81 6 47
4 13 1554.60 20 14.53 2410 700 3.44 / 650.51 6 57
5 13 896.68 20 14.70 1549 455 3.90 / 650.97 6 67
6 13 271.56 20 14.92 702 209 4.11 / 651.18 6 74
7 8 0.08 250 14.97 296 1108 5.22 / 652.29 6 152
Average= 16.31
(KJ/cycle)

Cycle 128 GMT 10/ 1/2023 22:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 23 14.98 418 144 0.14 / 642.00 6 13
2 7 2006.24 40 14.53 2985 1735 1.88 / 643.73 13 44
3 13 1977.72 20 14.51 2953 857 2.74 / 644.59 6 48
4 13 1511.44 20 14.55 2349 684 3.42 / 645.27 6 56
5 13 847.24 20 14.72 1482 436 3.86 / 645.71 6 68
6 13 307.56 20 14.90 753 224 4.08 / 645.93 6 75
7 13 35.08 20 15.00 364 109 4.19 / 646.04 6 68
8 8 -0.04 229 14.96 299 1024 5.21 / 647.07 6 134
Average= 16.59
(KJ/cycle)

Cycle 127 GMT 5/ 1/2023 23:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 23 14.99 421 145 0.15 / 636.73 6 13
2 7 2004.04 40 14.52 2985 1734 1.88 / 638.47 13 45
3 13 1976.72 20 14.50 2952 856 2.73 / 639.32 6 48
4 13 1584.60 20 14.54 2439 709 3.44 / 640.03 6 56
5 13 985.88 20 14.67 1665 489 3.93 / 640.52 6 66
6 13 273.12 20 14.92 703 210 4.14 / 640.73 6 74
7 13 20.36 20 15.01 341 102 4.24 / 640.83 6 65
8 8 0.04 229 14.97 298 1022 5.27 / 641.85 6 133
Average= 16.89
(KJ/cycle)

Cycle 126 GMT 31/12/2022 23:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 23 14.99 410 141 0.14 / 631.49 6 13
2 7 2004.96 40 14.52 2988 1735 1.88 / 633.23 13 45
3 13 1976.92 20 14.50 2954 857 2.73 / 634.08 6 48
4 13 1584.08 20 14.54 2448 712 3.45 / 634.79 6 57
5 13 985.80 20 14.67 1666 489 3.93 / 635.28 6 68
6 13 250.44 20 14.94 666 199 4.13 / 635.48 6 69
7 13 13.64 20 15.02 326 98 4.23 / 635.58 6 62
8 8 -0.12 229 14.97 294 1008 5.24 / 636.59 6 131
Average= 17.21
(KJ/cycle)

Cycle 125 GMT 27/12/2022 0:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 23 14.99 430 148 0.15 / 626.07 6 11
2 7 2011.96 40 14.53 2992 1739 1.89 / 627.81 11 46
3 13 1987.20 20 14.50 2974 862 2.75 / 628.67 6 49
4 13 1713.80 20 14.50 2615 758 3.51 / 629.43 6 54
5 13 1150.16 20 14.62 1876 549 4.06 / 629.98 6 65
6 13 331.24 20 14.90 775 231 4.29 / 630.21 6 70
7 13 61.00 20 15.00 401 120 4.41 / 630.33 6 67
8 8 0.08 231 14.97 295 1020 5.43 / 631.35 6 133
Average= 17.54
(KJ/cycle)

Cycle 124 GMT 22/12/2022 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 23 15.00 423 146 0.15 / 620.77 6 11
2 7 2013.96 40 14.52 2997 1741 1.89 / 622.51 11 43
3 13 1987.16 20 14.50 2960 858 2.74 / 623.37 6 47
4 13 1569.60 20 14.53 2421 704 3.45 / 624.07 6 54
5 13 975.08 20 14.67 1644 482 3.93 / 624.55 6 66
6 13 341.72 20 14.90 791 236 4.17 / 624.79 6 72
7 13 33.08 20 15.01 358 107 4.27 / 624.89 6 63
8 8 -0.04 231 14.97 297 1027 5.30 / 625.92 6 141
Average= 17.88
(KJ/cycle)

Cycle 123 GMT 17/12/2022 1:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 23 15.00 411 142 0.14 / 615.47 6 10
2 7 2007.08 40 14.52 2987 1735 1.88 / 617.20 10 45
3 13 1979.16 20 14.50 2957 858 2.73 / 618.06 6 48
4 13 1589.12 20 14.53 2457 714 3.45 / 618.77 6 56
5 13 1035.68 20 14.65 1728 506 3.95 / 619.28 6 64
6 13 289.80 20 14.92 716 214 4.17 / 619.49 6 70
7 13 52.88 20 15.00 385 115 4.28 / 619.61 6 62
8 8 0.00 231 14.97 293 1013 5.30 / 620.62 6 146
Average= 18.25
(KJ/cycle)

Cycle 122 GMT 12/12/2022 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 23 15.02 403 139 0.14 / 610.25 6 9
2 7 2003.92 40 14.51 2983 1731 1.87 / 611.98 9 45
3 13 1975.16 20 14.49 2944 853 2.72 / 612.83 6 47
4 13 1516.24 20 14.54 2358 686 3.41 / 613.52 6 55
5 13 969.52 20 14.68 1632 479 3.89 / 614.00 6 67
6 13 299.32 20 14.92 726 217 4.11 / 614.22 6 68
7 13 64.52 20 15.00 394 118 4.22 / 614.33 6 59
8 8 0.00 231 14.98 286 990 5.21 / 615.32 6 137
Average= 18.65
(KJ/cycle)

Cycle 121 GMT 7/12/2022 2:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 23 15.03 402 139 0.14 / 604.95 6 9
2 7 2015.36 40 14.52 2999 1742 1.88 / 606.70 9 45
3 13 1989.00 20 14.49 2969 860 2.74 / 607.56 6 48
4 13 1606.60 20 14.52 2477 719 3.46 / 608.28 6 55
5 13 1016.68 20 14.66 1703 499 3.96 / 608.78 6 66
6 13 358.28 20 14.91 802 239 4.20 / 609.01 6 65
7 13 85.76 20 15.01 416 125 4.32 / 609.14 6 54
8 8 0.04 233 14.99 278 971 5.29 / 610.11 6 167
Average= 19.07
(KJ/cycle)

Cycle 120 GMT 2/12/2022 3:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 23 15.03 402 139 0.14 / 599.76 6 8
2 7 2014.04 40 14.51 3001 1742 1.88 / 601.50 8 45
3 13 1984.76 20 14.49 2972 861 2.74 / 602.37 6 48
4 13 1553.44 20 14.54 2403 699 3.44 / 603.06 6 55
5 13 961.32 20 14.68 1624 477 3.92 / 603.54 6 66
6 13 265.12 20 14.95 672 201 4.12 / 603.74 6 62
7 13 43.72 20 15.03 351 106 4.22 / 603.85 6 51
8 8 0.20 233 15.00 277 968 5.19 / 604.82 6 -99
Average= 19.51
(KJ/cycle)

Cycle 119 GMT 27/11/2022 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 23 15.01 407 141 0.14 / 594.48 6 9
2 7 2012.24 40 14.52 2999 1742 1.88 / 596.23 9 46
3 13 1985.72 20 14.50 2966 860 2.74 / 597.09 6 46
4 13 1531.56 20 14.54 2382 693 3.44 / 597.78 6 58
5 13 1019.48 20 14.67 1705 500 3.94 / 598.28 6 64
6 13 351.72 20 14.91 796 237 4.17 / 598.52 6 66
7 13 80.00 20 15.01 408 122 4.30 / 598.64 6 53
8 13 24.68 20 15.03 323 97 4.39 / 598.74 6 49
9 8 -0.08 212 15.00 279 887 5.28 / 599.62 6 135
Average= 19.99
(KJ/cycle)

Cycle 118 GMT 22/11/2022 4:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 23 15.01 408 141 0.14 / 589.22 6 9
2 7 2006.56 40 14.53 2991 1738 1.88 / 590.95 9 45
3 13 1980.44 20 14.50 2965 860 2.74 / 591.81 6 46
4 13 1525.00 20 14.55 2378 692 3.43 / 592.51 6 58
5 13 938.84 20 14.70 1597 470 3.90 / 592.98 6 65
6 13 410.76 20 14.88 881 262 4.16 / 593.24 6 70
7 13 56.00 20 15.01 382 115 4.28 / 593.35 6 59
8 8 0.16 233 14.99 284 992 5.27 / 594.34 6 -99
Average= 20.49
(KJ/cycle)

Cycle 117 GMT 17/11/2022 4:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 23 15.01 407 141 0.14 / 583.94 6 10
2 7 2007.72 41 14.52 2998 1785 1.93 / 585.72 10 43
3 13 1979.28 20 14.50 2972 862 2.79 / 586.58 6 47
4 13 1558.36 20 14.54 2413 702 3.49 / 587.29 6 56
5 13 964.24 20 14.69 1633 480 3.97 / 587.77 6 66
6 13 260.68 20 14.94 678 203 4.17 / 587.97 6 67
7 13 34.32 20 15.02 352 106 4.28 / 588.07 6 58
8 8 0.24 231 14.99 289 1001 5.28 / 589.07 6 182
Average= 21.04
(KJ/cycle)

Cycle 116 GMT 12/11/2022 5:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 23 15.01 411 142 0.14 / 578.65 6 9
2 7 2004.28 40 14.53 2991 1738 1.88 / 580.39 9 44
3 13 1978.20 20 14.51 2963 860 2.74 / 581.25 6 47
4 13 1560.20 20 14.55 2425 706 3.45 / 581.96 6 57
5 13 1011.48 20 14.67 1699 498 3.94 / 582.46 6 65
6 13 309.12 20 14.92 744 222 4.17 / 582.68 6 68
7 13 36.52 20 15.02 357 107 4.27 / 582.79 6 59
8 8 -0.04 231 14.99 292 1011 5.28 / 583.80 6 134
Average= 21.62
(KJ/cycle)

Cycle 115 GMT 7/11/2022 6: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 23 15.02 412 142 0.14 / 573.34 6 9
2 7 2010.72 40 14.53 2998 1742 1.88 / 575.09 9 43
3 13 1982.52 20 14.51 2961 859 2.74 / 575.95 6 47
4 13 1625.68 20 14.53 2506 728 3.47 / 576.67 6 55
5 13 927.24 20 14.70 1582 465 3.94 / 577.14 6 65
6 13 376.20 20 14.90 832 248 4.19 / 577.39 6 69
7 13 31.60 20 15.03 352 106 4.29 / 577.49 6 59
8 8 0.08 233 14.99 292 1020 5.31 / 578.51 6 164
Average= 22.25
(KJ/cycle)

Cycle 114 GMT 2/11/2022 6:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 23 15.00 408 141 0.14 / 568.10 6 10
2 7 2010.20 40 14.53 2999 1743 1.88 / 569.84 10 45
3 13 1982.88 20 14.51 2967 861 2.74 / 570.71 6 49
4 13 1556.32 20 14.55 2417 703 3.45 / 571.41 6 54
5 13 957.96 20 14.70 1619 476 3.92 / 571.88 6 65
6 13 266.44 20 14.95 686 205 4.13 / 572.09 6 68
7 13 41.44 20 15.03 365 110 4.24 / 572.20 6 58
8 8 0.04 231 15.00 289 1001 5.24 / 573.20 6 137
Average= 22.93
(KJ/cycle)

Cycle 113 GMT 28/10/2022 7: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 23 15.02 408 141 0.14 / 562.82 6 9
2 7 2014.64 40 14.53 3005 1747 1.89 / 564.56 9 46
3 13 1986.88 20 14.51 2968 861 2.75 / 565.43 6 47
4 13 1598.80 20 14.53 2474 719 3.47 / 566.14 6 55
5 13 998.76 20 14.68 1677 492 3.96 / 566.64 6 65
6 13 231.76 20 14.96 645 193 4.15 / 566.83 6 70
7 13 39.68 20 15.02 365 110 4.26 / 566.94 6 63
8 8 -0.16 231 14.98 295 1021 5.28 / 567.96 6 171
Average= 23.67
(KJ/cycle)

Cycle 112 GMT 23/10/2022 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 23 15.01 413 143 0.14 / 557.52 6 9
2 7 2016.24 40 14.54 2998 1744 1.89 / 559.27 9 43
3 13 1989.48 20 14.51 2966 861 2.75 / 560.13 6 47
4 13 1569.60 20 14.55 2430 707 3.45 / 560.83 6 54
5 13 915.20 20 14.71 1562 460 3.91 / 561.29 6 66
6 13 362.88 20 14.90 821 245 4.16 / 561.54 6 73
7 13 40.72 20 15.02 372 112 4.27 / 561.65 6 63
8 8 0.08 233 14.99 294 1027 5.30 / 562.68 6 176
Average= 24.46
(KJ/cycle)

Cycle 111 GMT 18/10/2022 8: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 23 15.01 425 147 0.15 / 552.18 6 9
2 7 2013.04 40 14.53 3003 1745 1.89 / 553.93 9 44
3 13 1985.00 20 14.51 2983 866 2.76 / 554.79 6 46
4 13 1600.04 20 14.54 2464 717 3.47 / 555.51 6 56
5 13 1000.36 20 14.68 1680 493 3.97 / 556.00 6 66
6 13 336.52 20 14.91 795 237 4.20 / 556.24 6 74
7 13 32.96 20 15.02 364 109 4.31 / 556.35 6 66
8 8 0.00 231 14.98 298 1031 5.35 / 557.38 6 133
Average= 25.34
(KJ/cycle)

Cycle 110 GMT 13/10/2022 8:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 23 15.01 412 142 0.14 / 546.93 6 9
2 7 2008.96 40 14.54 2993 1741 1.88 / 548.67 9 44
3 13 1980.76 20 14.51 2957 858 2.74 / 549.53 6 48
4 13 1561.52 20 14.55 2416 703 3.44 / 550.24 6 54
5 13 935.32 20 14.70 1598 470 3.91 / 550.71 6 68
6 13 239.16 20 14.95 657 196 4.11 / 550.90 6 74
7 13 44.88 20 15.02 381 114 4.22 / 551.02 6 67
8 8 -0.08 229 14.98 297 1019 5.24 / 552.04 6 131
Average= 26.29
(KJ/cycle)

Cycle 109 GMT 8/10/2022 9: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 23 15.02 404 140 0.14 / 541.64 6 9
2 7 2005.64 40 14.53 2991 1738 1.88 / 543.38 9 44
3 13 1978.40 20 14.51 2961 859 2.74 / 544.24 6 47
4 13 1625.84 20 14.53 2496 725 3.46 / 544.96 6 56
5 13 958.08 20 14.70 1625 478 3.94 / 545.44 6 67
6 13 251.88 20 14.94 672 201 4.14 / 545.64 6 73
7 13 51.76 20 15.01 388 116 4.26 / 545.76 6 67
8 13 14.32 20 15.02 332 100 4.36 / 545.86 6 64
9 8 -0.04 210 14.98 297 934 5.29 / 546.79 6 143
Average= 27.34
(KJ/cycle)

Cycle 108 GMT 3/10/2022 9:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 23 15.02 418 144 0.14 / 536.35 6 9
2 7 2008.24 41 14.53 2999 1787 1.93 / 538.14 9 44
3 13 1980.40 20 14.51 2959 859 2.79 / 538.99 6 48
4 13 1485.12 20 14.57 2315 675 3.46 / 539.67 6 58
5 13 965.96 20 14.69 1635 480 3.94 / 540.15 6 65
6 13 334.96 20 14.92 776 232 4.18 / 540.38 6 69
7 13 52.52 20 15.02 382 115 4.29 / 540.50 6 61
8 8 0.00 231 14.99 290 1004 5.30 / 541.50 6 195
Average= 28.50
(KJ/cycle)

Cycle 107 GMT 28/ 9/2022 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 23 15.02 414 143 0.14 / 531.17 6 8
2 7 2004.40 40 14.53 2994 1740 1.88 / 532.91 8 46
3 13 1977.64 20 14.52 2963 860 2.74 / 533.77 6 48
4 13 1517.32 20 14.56 2358 687 3.43 / 534.45 6 58
5 13 902.80 20 14.72 1542 454 3.88 / 534.91 6 69
6 13 260.08 20 14.95 676 202 4.09 / 535.11 6 69
7 13 30.72 20 15.03 347 104 4.19 / 535.21 6 59
8 8 -0.08 231 15.00 286 991 5.18 / 536.20 6 243
Average= 29.79
(KJ/cycle)

Cycle 106 GMT 23/ 9/2022 10:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 23 15.03 412 142 0.14 / 525.92 6 8
2 7 2014.00 40 14.52 3008 1747 1.89 / 527.67 8 45
3 13 1984.40 20 14.50 2965 860 2.75 / 528.53 6 48
4 13 1521.92 20 14.55 2370 690 3.44 / 529.22 6 57
5 13 993.76 20 14.67 1677 492 3.93 / 529.71 6 67
6 13 289.56 20 14.94 716 214 4.14 / 529.93 6 67
7 13 61.12 20 15.02 388 117 4.26 / 530.04 6 55
8 8 0.08 231 15.00 283 981 5.24 / 531.02 6 141
Average= 31.24
(KJ/cycle)

Cycle 105 GMT 18/ 9/2022 11:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 23 15.05 402 139 0.14 / 520.71 6 8
2 7 2005.32 41 14.52 2997 1784 1.92 / 522.50 8 43
3 13 1975.84 20 14.50 2962 859 2.78 / 523.35 6 47
4 13 1479.80 20 14.56 2307 672 3.45 / 524.03 6 58
5 13 905.40 20 14.71 1561 459 3.91 / 524.49 6 67
6 13 278.64 20 14.95 694 208 4.12 / 524.69 6 62
7 13 89.24 20 15.02 424 127 4.25 / 524.82 6 52
8 8 0.12 231 15.01 277 960 5.21 / 525.78 6 -99
Average= 32.86
(KJ/cycle)

Cycle 104 GMT 13/ 9/2022 11:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 23 15.05 410 142 0.14 / 515.43 6 8
2 7 2008.92 41 14.52 2990 1780 1.92 / 517.21 8 45
3 13 1981.44 20 14.50 2957 858 2.78 / 518.07 6 48
4 13 1595.92 20 14.53 2468 717 3.50 / 518.79 6 56
5 13 993.36 20 14.68 1670 490 3.99 / 519.28 6 66
6 13 328.00 20 14.94 753 225 4.21 / 519.50 6 59
7 13 107.68 20 15.02 438 132 4.34 / 519.63 6 46
8 8 0.12 231 15.02 271 940 5.28 / 520.57 6 138
Average= 34.70
(KJ/cycle)

Cycle 103 GMT 8/ 9/2022 12:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 23 15.05 418 145 0.14 / 510.17 6 8
2 7 2011.32 40 14.52 2995 1739 1.88 / 511.90 8 47
3 13 1984.08 20 14.50 2969 861 2.75 / 512.77 6 48
4 13 1524.12 20 14.55 2366 689 3.43 / 513.45 6 56
5 13 1014.12 20 14.68 1685 495 3.93 / 513.95 6 65
6 13 342.16 20 14.94 774 231 4.16 / 514.18 6 61
7 13 150.36 20 15.01 500 150 4.31 / 514.33 6 51
8 13 20.12 20 15.05 311 94 4.40 / 514.42 6 41
9 8 0.00 214 15.02 269 865 5.27 / 515.29 6 -99
Average= 36.81
(KJ/cycle)

Cycle 102 GMT 3/ 9/2022 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 23 15.03 412 142 0.14 / 504.87 6 8
2 7 2012.24 40 14.54 3007 1749 1.89 / 506.62 8 44
3 13 1983.76 20 14.52 2965 861 2.75 / 507.48 6 48
4 13 1624.24 20 14.54 2495 726 3.48 / 508.21 6 57
5 13 976.08 20 14.70 1643 483 3.96 / 508.69 6 65
6 13 350.88 20 14.95 781 234 4.19 / 508.92 6 59
7 13 132.48 20 15.03 469 141 4.34 / 509.07 6 46
8 13 28.96 20 15.06 320 96 4.43 / 509.16 6 39
9 8 0.08 214 15.03 267 859 5.29 / 510.02 6 186
Average= 39.23
(KJ/cycle)

Cycle 101 GMT 29/ 8/2022 13:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 23 15.03 406 140 0.14 / 499.56 6 8
2 7 2010.04 41 14.53 3003 1789 1.93 / 501.35 8 45
3 13 1981.16 20 14.51 2961 859 2.79 / 502.20 6 49
4 13 1450.64 20 14.58 2271 662 3.45 / 502.87 6 59
5 13 1070.64 20 14.66 1770 519 3.97 / 503.39 6 65
6 13 314.00 20 14.94 749 224 4.19 / 503.61 6 67
7 13 120.56 20 15.01 469 141 4.33 / 503.75 6 58
8 8 0.08 233 15.01 280 979 5.31 / 504.73 6 -99
Average= 42.06
(KJ/cycle)

Cycle 100 GMT 24/ 8/2022 14: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 23 15.03 415 143 0.14 / 494.32 6 8
2 7 2014.80 40 14.53 3004 1746 1.89 / 496.07 8 44
3 13 1988.08 20 14.51 2971 862 2.75 / 496.93 6 48
4 13 1529.44 20 14.56 2375 692 3.44 / 497.62 6 57
5 13 935.44 20 14.71 1592 468 3.91 / 498.09 6 66
6 13 307.40 20 14.94 746 223 4.13 / 498.31 6 69
7 13 46.96 20 15.03 369 111 4.25 / 498.42 6 55
8 8 -0.04 231 15.01 286 992 5.24 / 499.42 6 135
Average= 45.40
(KJ/cycle)

Cycle 99 GMT 19/ 8/2022 14:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 23 15.05 415 144 0.14 / 489.00 6 8
2 7 2012.32 40 14.53 2999 1743 1.89 / 490.74 8 46
3 13 1986.08 20 14.51 2966 861 2.75 / 491.60 6 48
4 13 1638.24 20 14.53 2520 732 3.48 / 492.33 6 55
5 13 1030.12 20 14.67 1726 506 3.99 / 492.84 6 65
6 13 318.48 20 14.94 754 225 4.21 / 493.06 6 64
7 13 96.64 20 15.03 432 130 4.34 / 493.19 6 52
8 13 13.92 20 15.05 310 93 4.43 / 493.29 6 45
9 8 0.08 214 15.01 278 893 5.33 / 494.18 6 -99
Average= 49.42
(KJ/cycle)

Cycle 98 GMT 14/ 8/2022 15:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 23 15.05 420 145 0.15 / 483.81 6 8
2 7 2009.92 40 14.53 2996 1741 1.89 / 485.55 8 44
3 13 1981.20 20 14.52 2958 859 2.75 / 486.41 6 47
4 13 1291.64 20 14.63 2066 605 3.35 / 487.01 6 62
5 13 1037.68 20 14.68 1729 508 3.86 / 487.52 6 67
6 13 332.96 20 14.95 768 230 4.09 / 487.75 6 61
7 13 137.88 20 15.01 487 146 4.23 / 487.90 6 51
8 8 0.04 231 15.02 275 954 5.19 / 488.85 6 210
Average= 54.32
(KJ/cycle)

Cycle 97 GMT 9/ 8/2022 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 22 15.06 407 135 0.13 / 478.44 6 8
2 7 2010.76 40 14.54 3004 1747 1.88 / 480.19 8 45
3 13 1984.16 20 14.51 2967 861 2.74 / 481.05 6 46
4 13 1567.24 20 14.55 2431 707 3.45 / 481.75 6 56
5 13 1118.24 20 14.65 1841 539 3.99 / 482.29 6 64
6 13 395.92 20 14.91 857 256 4.25 / 482.55 6 66
7 13 124.24 20 15.02 471 141 4.39 / 482.69 6 53
8 8 0.08 233 15.02 278 973 5.36 / 483.66 6 151
Average= 60.46
(KJ/cycle)

Cycle 96 GMT 4/ 8/2022 16:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 22 15.06 413 137 0.14 / 473.10 6 7
2 7 2008.28 40 14.54 2996 1742 1.88 / 474.84 7 43
3 13 1979.28 20 14.51 2964 860 2.74 / 475.70 6 47
4 13 1658.52 20 14.53 2539 738 3.48 / 476.44 6 54
5 13 1101.56 20 14.66 1807 530 4.01 / 476.97 6 63
6 13 359.24 20 14.94 798 238 4.25 / 477.21 6 61
7 13 135.56 20 15.03 481 145 4.39 / 477.36 6 49
8 8 0.00 233 15.03 271 949 5.34 / 478.30 6 -99
Average= 68.33
(KJ/cycle)

Cycle 95 GMT 30/ 7/2022 16:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 22 15.06 412 137 0.14 / 467.75 6 7
2 7 2013.92 40 14.54 3006 1748 1.88 / 469.50 7 45
3 13 1987.80 20 14.51 2971 862 2.75 / 470.36 6 48
4 13 1568.28 20 14.55 2432 708 3.45 / 471.07 6 57
5 13 1019.04 20 14.69 1696 498 3.95 / 471.57 6 65
6 13 443.40 20 14.90 920 274 4.23 / 471.84 6 65
7 13 161.44 20 15.01 520 156 4.38 / 472.00 6 52
8 8 0.04 233 15.03 276 967 5.35 / 472.97 6 213
Average= 78.83
(KJ/cycle)

Cycle 94 GMT 25/ 7/2022 17:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 22 15.05 408 135 0.14 / 462.48 6 8
2 7 2009.56 41 14.54 2996 1786 1.92 / 464.27 8 44
3 13 1979.84 20 14.52 2953 858 2.78 / 465.12 6 47
4 13 1546.96 20 14.56 2391 696 3.47 / 465.82 6 56
5 13 960.20 20 14.71 1636 481 3.96 / 466.30 6 67
6 13 295.88 20 14.97 717 215 4.17 / 466.52 6 60
7 13 144.44 20 15.02 492 148 4.32 / 466.66 6 51
8 8 0.04 231 15.03 274 951 5.27 / 467.62 6 -99
Average= 93.52
(KJ/cycle)

Cycle 93 GMT 20/ 7/2022 18: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 22 15.05 401 133 0.13 / 457.27 6 8
2 7 2009.20 40 14.55 2994 1743 1.88 / 459.02 8 46
3 13 1979.32 20 14.53 2954 858 2.73 / 459.88 6 48
4 13 1474.64 20 14.59 2306 673 3.41 / 460.55 6 58
5 13 955.92 20 14.72 1619 477 3.88 / 461.03 6 66
6 13 315.40 20 14.96 745 223 4.11 / 461.25 6 64
7 13 125.36 20 15.02 473 142 4.25 / 461.39 6 54
8 8 0.08 231 15.03 275 955 5.20 / 462.35 6 -99
Average= 115.59
(KJ/cycle)

Cycle 92 GMT 15/ 7/2022 18:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 22 15.04 400 132 0.13 / 452.03 6 8
2 7 2014.32 40 14.54 3000 1745 1.88 / 453.77 8 45
3 13 1986.08 20 14.52 2974 864 2.74 / 454.64 6 48
4 13 1517.60 20 14.58 2359 688 3.43 / 455.32 6 57
5 13 991.76 20 14.71 1666 490 3.92 / 455.82 6 65
6 13 328.28 20 14.95 768 230 4.15 / 456.04 6 67
7 13 58.36 20 15.05 382 115 4.26 / 456.16 6 55
8 8 0.12 231 15.03 283 983 5.25 / 457.14 6 147
Average= 152.38
(KJ/cycle)

Cycle 91 GMT 10/ 7/2022 19:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 22 15.04 401 133 0.13 / 446.73 6 7
2 7 2003.48 40 14.56 2992 1743 1.88 / 448.47 7 45
3 13 1974.60 20 14.53 2956 859 2.73 / 449.33 6 48
4 13 1545.24 20 14.58 2391 697 3.43 / 450.03 6 56
5 13 1094.48 20 14.67 1807 530 3.96 / 450.56 6 65
6 13 313.00 20 14.95 753 225 4.19 / 450.79 6 69
7 13 40.40 20 15.05 360 108 4.30 / 450.89 6 58
8 8 0.00 231 15.02 289 1003 5.30 / 451.90 6 138
Average= 225.95
(KJ/cycle)

Cycle 90 GMT 5/ 7/2022 19:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 22 15.04 411 136 0.14 / 441.45 6 8
2 7 2013.00 40 14.55 3001 1747 1.88 / 443.20 8 46
3 13 1984.96 20 14.53 2972 864 2.75 / 444.06 6 49
4 13 1459.36 20 14.60 2292 669 3.42 / 444.73 6 59
5 13 918.16 20 14.74 1560 460 3.88 / 445.19 6 67
6 13 464.28 20 14.88 958 285 4.16 / 445.48 6 73
7 13 28.32 20 15.05 350 105 4.27 / 445.58 6 61
8 8 0.36 231 15.01 293 1016 5.28 / 446.60 6 137
Average= 446.60
(KJ/cycle)

Cycle 87 GMT 20/ 6/2022 21:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 22 15.05 405 134 0.13 / 436.21 6 8
2 7 2008.28 40 14.56 2994 1744 1.88 / 437.95 8 45
3 13 1981.44 20 14.54 2970 864 2.74 / 438.82 6 49
4 13 1531.36 20 14.59 2378 694 3.44 / 439.51 6 57
5 13 980.32 20 14.73 1656 488 3.92 / 440.00 6 66
6 13 314.52 20 14.98 742 222 4.15 / 440.22 6 60
7 13 120.32 20 15.05 460 138 4.28 / 440.36 6 50
8 8 0.16 231 15.05 275 956 5.24 / 441.32 6 146
Average= 5.01
(KJ/cycle)

Cycle 86 GMT 15/ 6/2022 21:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 22 15.07 410 136 0.14 / 430.93 6 8
2 7 2005.60 40 14.55 2988 1739 1.87 / 432.67 8 45
3 13 1974.72 20 14.53 2956 859 2.73 / 433.53 6 49
4 13 1544.32 20 14.58 2392 698 3.43 / 434.23 6 58
5 13 924.32 20 14.74 1586 468 3.90 / 434.70 6 68
6 13 439.84 20 14.91 917 273 4.17 / 434.97 6 69
7 13 43.20 20 15.05 367 110 4.28 / 435.08 6 57
8 8 0.08 231 15.02 287 996 5.28 / 436.08 6 137
Average= 5.01
(KJ/cycle)

Cycle 85 GMT 10/ 6/2022 22:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 22 15.05 407 135 0.13 / 425.61 6 8
2 3 1520.60 1 14.98 2405 36 0.17 / 425.65 6 29
3 7 2004.04 40 14.56 2992 1743 1.91 / 427.39 29 45
4 13 1976.20 20 14.54 2954 859 2.77 / 428.25 6 48
5 13 1692.88 20 14.55 2591 754 3.53 / 429.00 6 54
6 13 977.72 20 14.73 1649 486 4.01 / 429.49 6 66
7 13 273.68 20 14.99 683 205 4.22 / 429.69 6 62
8 13 82.28 20 15.06 416 125 4.34 / 429.82 6 53
9 8 0.08 231 15.04 282 980 5.32 / 430.80 6 164
Average= 5.01
(KJ/cycle)

Cycle 84 GMT 5/ 6/2022 22:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 22 15.05 418 138 0.14 / 420.34 6 9
2 7 2010.84 40 14.56 2997 1745 1.88 / 422.08 9 45
3 13 1983.52 20 14.54 2968 863 2.75 / 422.95 6 47
4 13 1563.84 20 14.59 2413 704 3.45 / 423.65 6 55
5 13 973.60 20 14.73 1635 482 3.93 / 424.13 6 65
6 13 306.88 20 14.97 738 221 4.15 / 424.35 6 69
7 13 78.00 20 15.05 417 126 4.28 / 424.48 6 59
8 8 -0.16 231 15.03 287 996 5.28 / 425.48 6 139
Average= 5.01
(KJ/cycle)

Cycle 83 GMT 31/ 5/2022 23:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 22 15.04 412 136 0.14 / 415.21 6 9
2 7 2016.08 40 14.56 3008 1752 1.89 / 416.97 9 44
3 13 1990.36 20 14.54 2972 864 2.75 / 417.83 6 48
4 13 1380.68 20 14.64 2184 639 3.39 / 418.47 6 58
5 13 915.92 20 14.75 1576 465 3.86 / 418.94 6 67
6 13 151.52 20 15.03 528 159 4.02 / 419.09 6 67
7 13 23.84 20 15.07 342 103 4.12 / 419.20 6 59
8 8 0.32 227 15.03 294 1003 5.12 / 420.20 6 130
Average= 5.00
(KJ/cycle)

Cycle 82 GMT 27/ 5/2022 0: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 21 15.06 405 128 0.13 / 410.27 6 9
2 3 1542.92 1 14.89 2435 36 0.16 / 410.31 6 48
3 7 1826.64 40 14.62 2761 1615 1.78 / 411.92 48 48
4 13 1800.36 20 14.61 2716 794 2.57 / 412.71 6 50
5 13 1390.20 20 14.64 2196 643 3.22 / 413.36 6 59
6 13 837.84 20 14.78 1469 434 3.65 / 413.79 6 70
7 13 171.12 20 15.02 558 168 3.82 / 413.96 6 68
8 13 26.56 20 15.07 351 106 3.92 / 414.07 6 61
9 8 -0.12 227 15.03 297 1013 4.94 / 415.08 6 145
Average= 5.00
(KJ/cycle)

Cycle 81 GMT 22/ 5/2022 0:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 22 15.06 406 135 0.13 / 405.74 6 9
2 3 1460.80 -1 15.40 6 0 0.00 / 405.74 6 9
3 7 1545.52 40 14.73 2383 1404 1.54 / 407.14 9 55
4 13 1523.28 20 14.71 2365 696 2.23 / 407.84 6 57
5 13 1422.92 20 14.68 2237 657 2.89 / 408.49 6 61
6 13 844.48 20 14.81 1475 437 3.33 / 408.93 6 70
7 13 120.36 20 15.06 478 144 3.47 / 409.07 6 62
8 13 11.92 20 15.09 316 95 3.57 / 409.17 6 57
9 8 0.04 225 15.05 287 972 4.54 / 410.14 6 165
Average= 5.00
(KJ/cycle)

Cycle 80 GMT 17/ 5/2022 2: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 22 15.06 423 140 0.14 / 401.08 6 10
2 7 1580.16 40 14.72 2435 1434 1.57 / 402.52 10 52
3 13 1573.72 20 14.70 2430 714 2.29 / 403.23 6 54
4 13 1506.60 20 14.66 2346 688 2.98 / 403.92 6 58
5 13 874.96 20 14.79 1519 449 3.43 / 404.37 6 69
6 13 158.24 20 15.05 535 161 3.59 / 404.53 6 64
7 8 2.76 246 15.05 290 1074 4.66 / 405.60 6 159
Average= 5.01
(KJ/cycle)

Cycle 79 GMT 12/ 5/2022 3:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 22 15.07 399 132 0.13 / 396.21 6 10
2 7 1754.68 40 14.66 2653 1556 1.69 / 397.76 10 49
3 13 1730.60 20 14.64 2632 771 2.46 / 398.53 6 52
4 13 1423.84 20 14.66 2234 655 3.11 / 399.19 6 58
5 13 974.16 20 14.75 1650 487 3.60 / 399.68 6 67
6 13 171.56 20 15.03 551 166 3.77 / 399.84 6 64
7 13 26.04 20 15.08 345 104 3.87 / 399.95 6 58
8 8 0.12 227 15.04 292 997 4.87 / 400.94 6 137
Average= 5.01
(KJ/cycle)

Cycle 78 GMT 7/ 5/2022 4:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 22 15.07 421 140 0.14 / 391.40 6 10
2 7 1728.76 40 14.67 2623 1539 1.68 / 392.94 10 49
3 13 1704.00 20 14.65 2586 758 2.44 / 393.69 6 52
4 13 1495.24 20 14.64 2328 682 3.12 / 394.37 6 58
5 13 933.48 20 14.77 1582 467 3.59 / 394.84 6 68
6 13 154.04 20 15.05 524 158 3.74 / 395.00 6 63
7 13 20.20 20 15.09 328 99 3.84 / 395.10 6 56
8 8 -0.08 227 15.05 286 977 4.82 / 396.08 6 139
Average= 5.01
(KJ/cycle)

Cycle 77 GMT 2/ 5/2022 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 22 15.07 419 139 0.14 / 386.98 6 11
2 7 1490.00 40 14.76 2312 1365 1.50 / 388.34 11 55
3 13 1469.68 20 14.75 2288 675 2.18 / 389.02 6 58
4 13 1338.88 20 14.72 2113 622 2.80 / 389.64 6 61
5 13 820.16 20 14.84 1436 426 3.23 / 390.07 6 67
6 13 73.40 20 15.09 415 125 3.35 / 390.19 6 59
7 8 0.04 244 15.06 290 1066 4.42 / 391.26 6 160
Average= 5.02
(KJ/cycle)

Cycle 76 GMT 27/ 4/2022 6:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 22 15.07 408 135 0.14 / 382.44 6 11
2 7 1571.36 41 14.73 2415 1458 1.59 / 383.90 11 52
3 13 1549.16 20 14.72 2395 705 2.30 / 384.61 6 56
4 13 1348.72 20 14.70 2135 628 2.93 / 385.23 6 62
5 13 765.48 20 14.85 1363 405 3.33 / 385.64 6 70
6 13 124.28 20 15.07 480 145 3.48 / 385.78 6 61
7 8 -0.08 244 15.06 287 1055 4.53 / 386.84 6 147
Average= 5.02
(KJ/cycle)

Cycle 75 GMT 22/ 4/2022 7:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 22 15.07 414 137 0.14 / 377.73 6 10
2 7 1698.84 40 14.69 2590 1522 1.66 / 379.25 10 50
3 13 1675.16 20 14.67 2557 750 2.41 / 380.00 6 53
4 13 1470.60 20 14.66 2288 671 3.08 / 380.67 6 58
5 13 814.92 20 14.82 1437 426 3.51 / 381.10 6 69
6 13 120.56 20 15.07 478 144 3.65 / 381.24 6 60
7 8 0.12 246 15.07 287 1064 4.71 / 382.31 6 144
Average= 5.03
(KJ/cycle)

Cycle 74 GMT 17/ 4/2022 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 22 15.07 417 138 0.14 / 372.82 6 10
2 7 1750.48 40 14.67 2660 1561 1.70 / 374.38 10 50
3 13 1732.24 20 14.65 2634 772 2.47 / 375.16 6 52
4 13 1527.08 20 14.64 2372 695 3.17 / 375.85 6 58
5 13 892.32 20 14.79 1538 455 3.62 / 376.31 6 68
6 13 218.16 20 15.03 615 185 3.81 / 376.49 6 64
7 13 16.20 20 15.10 330 100 3.90 / 376.59 6 55
8 8 0.00 229 15.06 291 1004 4.91 / 377.59 6 -99
Average= 5.03
(KJ/cycle)

Cycle 73 GMT 12/ 4/2022 9:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 22 15.06 413 137 0.14 / 367.60 6 11
2 7 1972.16 40 14.59 2942 1717 1.85 / 369.32 11 45
3 13 1942.36 20 14.57 2914 849 2.70 / 370.17 6 49
4 13 1589.76 20 14.60 2462 719 3.42 / 370.89 6 56
5 13 920.76 20 14.77 1575 465 3.89 / 371.35 6 67
6 13 326.40 20 14.98 765 229 4.12 / 371.58 6 68
7 13 23.24 20 15.09 334 101 4.22 / 371.68 6 56
8 8 0.08 231 15.05 289 1005 5.22 / 372.69 6 -99
Average= 5.04
(KJ/cycle)

Cycle 72 GMT 7/ 4/2022 10: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 22 15.07 409 136 0.14 / 362.53 6 11
2 7 1880.32 40 14.63 2811 1645 1.78 / 364.18 11 48
3 13 1852.48 20 14.61 2777 811 2.59 / 364.99 6 50
4 13 1529.96 20 14.64 2366 693 3.28 / 365.68 6 56
5 13 1035.84 20 14.74 1718 506 3.79 / 366.19 6 65
6 13 220.40 20 15.03 624 188 3.98 / 366.38 6 65
7 8 0.00 250 15.06 289 1088 5.07 / 367.46 6 -99
Average= 5.03
(KJ/cycle)

Cycle 71 GMT 2/ 4/2022 10:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 22 15.07 432 143 0.14 / 357.36 6 13
2 7 1993.36 41 14.59 2968 1775 1.92 / 359.13 13 45
3 13 1963.12 20 14.57 2942 857 2.78 / 359.99 6 49
4 13 1392.56 20 14.66 2192 643 3.42 / 360.63 6 59
5 13 892.00 20 14.79 1534 454 3.87 / 361.09 6 67
6 13 266.84 20 15.01 689 207 4.08 / 361.29 6 69
7 13 34.60 20 15.09 354 107 4.19 / 361.40 6 57
8 8 -0.12 227 15.06 291 995 5.18 / 362.40 6 131
Average= 5.03
(KJ/cycle)

Cycle 70 GMT 28/ 3/2022 10:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 22 15.06 422 140 0.14 / 352.28 6 14
2 7 1918.32 41 14.62 2872 1722 1.86 / 354.00 14 47
3 13 1891.52 20 14.60 2841 830 2.69 / 354.83 6 49
4 13 1446.84 20 14.65 2272 666 3.36 / 355.50 6 59
5 13 964.56 20 14.77 1627 481 3.84 / 355.98 6 65
6 13 150.16 20 15.06 524 158 4.00 / 356.14 6 66
7 8 0.16 246 15.06 291 1078 5.07 / 357.22 6 140
Average= 5.03
(KJ/cycle)

Cycle 69 GMT 23/ 3/2022 11:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 22 15.06 436 144 0.14 / 347.12 6 13
2 7 2007.60 40 14.58 2993 1746 1.89 / 348.86 13 45
3 13 1976.24 20 14.57 2953 861 2.75 / 349.72 6 49
4 13 1484.80 20 14.64 2321 680 3.43 / 350.40 6 58
5 13 819.88 20 14.82 1446 429 3.86 / 350.83 6 71
6 13 257.00 20 15.01 684 205 4.06 / 351.04 6 74
7 8 0.04 246 15.06 298 1104 5.17 / 352.14 6 138
Average= 5.03
(KJ/cycle)

Cycle 68 GMT 18/ 3/2022 11:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 22 15.07 417 138 0.14 / 341.80 6 13
2 7 2013.12 40 14.59 3008 1755 1.89 / 343.55 13 45
3 13 1985.28 20 14.57 2974 867 2.76 / 344.42 6 49
4 13 1568.48 20 14.62 2437 713 3.47 / 345.13 6 56
5 13 974.28 20 14.76 1655 489 3.96 / 345.62 6 68
6 13 330.28 20 14.98 787 236 4.20 / 345.85 6 76
7 8 -0.16 248 15.05 300 1120 5.32 / 346.97 6 138
Average= 5.03
(KJ/cycle)

Cycle 67 GMT 13/ 3/2022 12:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 22 15.08 414 137 0.14 / 336.46 6 10
2 7 2014.80 40 14.59 2996 1748 1.89 / 338.20 10 46
3 13 1987.00 20 14.57 2971 866 2.75 / 339.07 6 48
4 13 1670.44 20 14.59 2562 748 3.50 / 339.82 6 54
5 13 1022.00 20 14.75 1705 503 4.00 / 340.32 6 67
6 13 206.64 20 15.03 616 185 4.19 / 340.51 6 73
7 13 59.24 20 15.08 399 120 4.31 / 340.63 6 66
8 8 0.12 229 15.06 299 1031 5.34 / 341.66 6 141
Average= 5.02
(KJ/cycle)

Cycle 66 GMT 8/ 3/2022 12:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 22 15.08 434 144 0.14 / 331.27 6 12
2 7 2008.52 40 14.59 2998 1750 1.89 / 333.02 12 46
3 13 1979.44 20 14.57 2959 862 2.76 / 333.88 6 47
4 13 1489.04 20 14.65 2326 682 3.44 / 334.56 6 58
5 13 932.20 20 14.79 1593 471 3.91 / 335.03 6 67
6 13 223.52 20 15.03 632 190 4.10 / 335.22 6 69
7 8 -0.04 246 15.07 295 1094 5.19 / 336.32 6 129
Average= 5.02
(KJ/cycle)

Cycle 65 GMT 3/ 3/2022 13:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 22 15.08 430 143 0.14 / 326.11 6 12
2 7 2012.08 40 14.59 2996 1748 1.89 / 327.86 12 46
3 13 1983.80 20 14.58 2966 865 2.76 / 328.72 6 48
4 13 1491.32 20 14.65 2323 681 3.44 / 329.40 6 57
5 13 845.84 20 14.82 1475 437 3.87 / 329.84 6 69
6 13 191.56 20 15.06 583 176 4.05 / 330.02 6 67
7 8 0.00 248 15.07 297 1110 5.16 / 331.13 6 137
Average= 5.02
(KJ/cycle)

Cycle 64 GMT 26/ 2/2022 13:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 22 15.08 432 143 0.14 / 320.75 6 12
2 7 2012.40 41 14.59 2998 1793 1.94 / 322.54 12 45
3 13 1984.56 20 14.58 2963 864 2.80 / 323.40 6 49
4 13 1671.00 20 14.60 2553 745 3.55 / 324.15 6 55
5 13 982.16 20 14.78 1651 488 4.03 / 324.64 6 66
6 13 303.80 20 15.01 745 224 4.26 / 324.86 6 72
7 8 0.04 248 15.07 296 1106 5.36 / 325.97 6 130
Average= 5.01
(KJ/cycle)

Cycle 63 GMT 21/ 2/2022 14:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 22 15.08 435 144 0.14 / 315.36 6 13
2 7 2014.88 40 14.60 2999 1751 1.90 / 317.11 13 45
3 13 1986.88 20 14.58 2967 865 2.76 / 317.98 6 49
4 13 1592.96 20 14.63 2467 722 3.48 / 318.70 6 56
5 13 934.44 20 14.79 1591 471 3.95 / 319.17 6 66
6 13 449.12 20 14.95 941 281 4.23 / 319.45 6 73
7 13 22.24 20 15.11 346 105 4.34 / 319.56 6 60
8 8 -0.08 231 15.07 300 1044 5.38 / 320.60 6 146
Average= 5.01
(KJ/cycle)

Cycle 62 GMT 16/ 2/2022 14:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 22 15.10 421 140 0.14 / 310.07 6 10
2 7 2015.60 41 14.59 3012 1802 1.94 / 311.87 10 45
3 13 1987.32 20 14.58 2973 867 2.81 / 312.74 6 48
4 13 1559.60 20 14.63 2429 711 3.52 / 313.45 6 57
5 13 949.80 20 14.79 1623 480 4.00 / 313.93 6 68
6 13 212.64 20 15.05 618 186 4.19 / 314.12 6 66
7 8 0.16 248 15.08 295 1103 5.29 / 315.22 6 138
Average= 5.00
(KJ/cycle)

Cycle 61 GMT 11/ 2/2022 15:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 22 15.10 415 138 0.14 / 304.75 6 10
2 7 2013.08 40 14.60 2994 1748 1.89 / 306.50 10 44
3 13 1984.56 20 14.59 2960 864 2.75 / 307.37 6 49
4 13 1632.60 20 14.62 2508 733 3.48 / 308.10 6 56
5 13 998.24 20 14.78 1675 495 3.98 / 308.60 6 65
6 13 259.80 20 15.04 679 204 4.18 / 308.80 6 66
7 13 73.68 20 15.11 415 125 4.31 / 308.92 6 56
8 8 -0.04 233 15.09 286 1006 5.31 / 309.93 6 -99
Average= 5.00
(KJ/cycle)

Cycle 60 GMT 6/ 2/2022 15:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 22 15.12 419 139 0.14 / 299.48 6 9
2 7 2013.32 40 14.60 3001 1753 1.89 / 301.23 9 44
3 13 1984.04 20 14.58 2965 865 2.76 / 302.10 6 48
4 13 1628.36 20 14.62 2506 733 3.49 / 302.83 6 56
5 13 933.84 20 14.81 1588 470 3.96 / 303.30 6 67
6 13 263.92 20 15.04 687 207 4.17 / 303.51 6 68
7 13 18.00 20 15.13 332 100 4.27 / 303.61 6 55
8 8 0.00 229 15.09 292 1009 5.28 / 304.62 6 130
Average= 4.99
(KJ/cycle)

Cycle 59 GMT 1/ 2/2022 16: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 22 15.11 414 138 0.14 / 294.29 6 9
2 7 2007.88 40 14.60 2990 1746 1.88 / 296.03 9 44
3 13 1979.76 20 14.59 2960 864 2.75 / 296.90 6 48
4 13 1514.56 20 14.66 2360 692 3.44 / 297.59 6 57
5 13 890.96 20 14.83 1530 454 3.89 / 298.04 6 66
6 13 239.84 20 15.07 636 192 4.08 / 298.23 6 58
7 13 88.96 20 15.12 421 127 4.21 / 298.36 6 50
8 8 -0.08 231 15.10 281 980 5.19 / 299.34 6 -99
Average= 4.99
(KJ/cycle)

Cycle 58 GMT 27/ 1/2022 16:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 22 15.13 415 138 0.14 / 288.96 6 9
2 7 2003.72 40 14.61 2987 1746 1.88 / 290.71 9 46
3 13 1975.04 20 14.60 2949 861 2.74 / 291.57 6 47
4 13 1614.48 20 14.64 2492 730 3.47 / 292.30 6 56
5 13 991.44 20 14.79 1662 492 3.97 / 292.79 6 66
6 13 386.36 20 15.01 846 254 4.22 / 293.05 6 68
7 13 73.88 20 15.12 403 122 4.34 / 293.17 6 53
8 8 0.04 231 15.10 281 980 5.32 / 294.15 6 156
Average= 4.99
(KJ/cycle)

Cycle 57 GMT 22/ 1/2022 17:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 22 15.10 422 140 0.14 / 283.69 6 11
2 7 2014.88 40 14.61 3000 1753 1.89 / 285.45 11 45
3 13 1987.20 20 14.60 2964 865 2.76 / 286.31 6 48
4 13 1560.40 20 14.66 2421 710 3.47 / 287.02 6 56
5 13 969.12 20 14.80 1642 486 3.95 / 287.51 6 66
6 13 266.88 20 15.06 687 207 4.16 / 287.71 6 66
7 13 77.24 20 15.12 412 125 4.29 / 287.84 6 55
8 8 0.08 231 15.10 283 987 5.27 / 288.83 6 186
Average= 4.98
(KJ/cycle)

Cycle 56 GMT 17/ 1/2022 17:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 22 15.12 411 137 0.14 / 278.39 6 9
2 7 2014.32 40 14.60 3010 1758 1.89 / 280.14 9 46
3 13 1984.68 20 14.59 2973 868 2.76 / 281.01 6 48
4 13 1555.80 20 14.66 2416 708 3.47 / 281.72 6 57
5 13 989.48 20 14.80 1671 495 3.97 / 282.21 6 66
6 13 274.24 20 15.05 699 210 4.18 / 282.42 6 67
7 13 72.72 20 15.12 414 125 4.30 / 282.55 6 60
8 8 -0.04 229 15.10 290 1003 5.30 / 283.55 6 142
Average= 4.97
(KJ/cycle)

Cycle 55 GMT 12/ 1/2022 18:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 22 15.11 416 138 0.14 / 273.19 6 12
2 7 2013.32 40 14.61 3005 1756 1.89 / 274.95 12 46
3 13 1986.60 20 14.60 2968 867 2.76 / 275.81 6 47
4 13 1489.64 20 14.68 2331 684 3.45 / 276.50 6 57
5 13 899.04 20 14.83 1551 460 3.91 / 276.96 6 68
6 13 200.12 20 15.08 599 181 4.09 / 277.14 6 66
7 13 28.56 20 15.14 346 105 4.19 / 277.24 6 55
8 8 0.04 229 15.10 291 1006 5.20 / 278.25 6 162
Average= 4.97
(KJ/cycle)

Cycle 54 GMT 7/ 1/2022 18:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 22 15.11 417 139 0.14 / 267.96 6 12
2 7 2008.88 40 14.62 2996 1752 1.89 / 269.71 12 45
3 13 1981.20 20 14.61 2966 867 2.76 / 270.58 6 48
4 13 1522.88 20 14.67 2370 695 3.45 / 271.27 6 57
5 13 925.88 20 14.83 1585 470 3.92 / 271.74 6 67
6 13 228.52 20 15.07 640 193 4.12 / 271.94 6 68
7 13 18.40 20 15.15 335 102 4.22 / 272.04 6 58
8 8 0.00 227 15.10 296 1015 5.23 / 273.05 6 130
Average= 4.96
(KJ/cycle)

Cycle 53 GMT 2/ 1/2022 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 21 15.11 411 130 0.13 / 262.69 6 11
2 7 2005.28 40 14.62 2995 1751 1.88 / 264.44 11 44
3 13 1977.64 20 14.61 2966 867 2.75 / 265.31 6 48
4 13 1523.80 20 14.68 2366 695 3.44 / 266.00 6 56
5 13 1002.04 20 14.80 1687 499 3.94 / 266.50 6 67
6 13 220.44 20 15.08 628 189 4.13 / 266.69 6 69
7 13 28.84 20 15.14 353 107 4.24 / 266.80 6 62
8 8 -0.04 227 15.10 298 1021 5.26 / 267.82 6 133
Average= 4.96
(KJ/cycle)

Cycle 52 GMT 28/12/2021 19:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 21 15.11 423 134 0.13 / 257.34 6 12
2 7 2012.28 40 14.62 2996 1752 1.89 / 259.09 12 45
3 13 1983.96 20 14.61 2962 865 2.75 / 259.96 6 48
4 13 1699.12 20 14.64 2595 760 3.51 / 260.72 6 54
5 13 988.28 20 14.82 1660 492 4.00 / 261.21 6 66
6 13 287.08 20 15.06 722 217 4.22 / 261.43 6 71
7 13 48.04 20 15.14 377 114 4.34 / 261.54 6 62
8 8 -0.08 229 15.10 295 1020 5.36 / 262.56 6 135
Average= 4.95
(KJ/cycle)

Cycle 51 GMT 23/12/2021 20:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 21 15.12 422 134 0.13 / 252.09 6 10
2 7 2008.16 41 14.62 2980 1786 1.92 / 253.87 10 47
3 13 1976.88 20 14.61 2937 858 2.78 / 254.73 6 47
4 13 1577.72 20 14.66 2441 716 3.49 / 255.45 6 56
5 13 876.44 20 14.85 1517 451 3.94 / 255.90 6 69
6 13 213.36 20 15.08 622 188 4.13 / 256.08 6 68
7 8 0.08 248 15.11 299 1120 5.25 / 257.20 6 135
Average= 4.95
(KJ/cycle)

Cycle 50 GMT 18/12/2021 20:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 21 15.12 423 134 0.13 / 246.83 6 11
2 7 2014.72 40 14.62 2998 1753 1.89 / 248.58 11 45
3 13 1984.92 20 14.61 2968 867 2.75 / 249.45 6 47
4 13 1593.32 20 14.66 2466 723 3.48 / 250.17 6 55
5 13 859.68 20 14.86 1504 447 3.92 / 250.62 6 69
6 13 240.80 20 15.08 663 200 4.12 / 250.82 6 67
7 13 23.48 20 15.15 345 105 4.23 / 250.92 6 58
8 8 -0.20 229 15.11 298 1031 5.26 / 251.95 6 129
Average= 4.94
(KJ/cycle)

Cycle 49 GMT 13/12/2021 20:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 21 15.12 416 132 0.13 / 241.57 6 11
2 7 2013.32 40 14.62 3006 1758 1.89 / 243.32 11 45
3 13 1984.92 20 14.61 2968 867 2.76 / 244.19 6 48
4 13 1502.48 20 14.69 2352 691 3.45 / 244.88 6 57
5 13 903.96 20 14.85 1554 462 3.91 / 245.34 6 67
6 13 249.84 20 15.08 669 202 4.11 / 245.55 6 68
7 13 53.52 20 15.14 388 117 4.23 / 245.66 6 60
8 8 0.08 229 15.11 297 1028 5.26 / 246.69 6 134
Average= 4.93
(KJ/cycle)

Cycle 48 GMT 8/12/2021 21:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 21 15.13 419 133 0.13 / 236.32 6 10
2 7 2004.92 40 14.63 2989 1749 1.88 / 238.07 10 45
3 13 1977.16 20 14.62 2954 864 2.75 / 238.94 6 48
4 13 1509.52 20 14.69 2358 693 3.44 / 239.63 6 58
5 13 914.60 20 14.85 1578 469 3.91 / 240.10 6 67
6 13 248.40 20 15.08 670 202 4.11 / 240.30 6 68
7 13 52.88 20 15.15 389 118 4.23 / 240.42 6 61
8 8 0.00 229 15.12 294 1018 5.25 / 241.43 6 163
Average= 4.93
(KJ/cycle)

Cycle 47 GMT 3/12/2021 22: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 21 15.15 420 134 0.13 / 230.92 6 8
2 7 2007.36 40 14.62 2993 1750 1.88 / 232.67 8 46
3 13 1978.40 20 14.62 2948 862 2.75 / 233.53 6 49
4 13 1590.52 20 14.67 2458 721 3.47 / 234.25 6 56
5 13 983.36 20 14.83 1665 494 3.96 / 234.74 6 66
6 13 512.12 20 14.98 1018 305 4.27 / 235.05 6 72
7 13 54.96 20 15.15 387 117 4.38 / 235.17 6 59
8 8 0.04 231 15.12 293 1023 5.41 / 236.19 6 158
Average= 4.92
(KJ/cycle)

Cycle 46 GMT 28/11/2021 22:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 21 15.15 415 132 0.13 / 225.68 6 8
2 7 2010.08 40 14.62 2997 1753 1.88 / 227.44 8 45
3 13 1981.16 20 14.61 2957 864 2.75 / 228.30 6 48
4 13 1508.56 20 14.70 2345 689 3.44 / 228.99 6 58
5 13 950.12 20 14.84 1617 480 3.92 / 229.47 6 67
6 13 277.56 20 15.09 694 209 4.13 / 229.68 6 62
7 13 92.44 20 15.15 425 129 4.26 / 229.81 6 50
8 8 0.04 231 15.14 279 976 5.23 / 230.78 6 173
Average= 4.91
(KJ/cycle)

Cycle 45 GMT 23/11/2021 23: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 21 15.16 405 129 0.13 / 220.45 6 9
2 7 2011.28 40 14.62 3001 1755 1.88 / 222.20 9 45
3 13 1982.28 20 14.61 2968 867 2.75 / 223.07 6 48
4 13 1547.76 20 14.69 2402 706 3.46 / 223.78 6 57
5 13 949.68 20 14.85 1606 477 3.93 / 224.25 6 66
6 13 239.68 20 15.10 646 195 4.13 / 224.45 6 63
7 13 93.04 20 15.15 433 131 4.26 / 224.58 6 54
8 8 0.08 229 15.14 280 971 5.23 / 225.55 6 133
Average= 4.90
(KJ/cycle)

Cycle 44 GMT 18/11/2021 23:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 21 15.16 400 127 0.13 / 215.20 6 9
2 7 2014.80 40 14.62 3002 1756 1.88 / 216.96 9 45
3 13 1986.60 20 14.62 2976 870 2.75 / 217.83 6 48
4 13 1529.84 20 14.69 2385 701 3.45 / 218.53 6 58
5 13 967.28 20 14.84 1636 486 3.94 / 219.01 6 66
6 13 254.28 20 15.11 657 199 4.14 / 219.21 6 56
7 13 114.12 20 15.16 457 139 4.28 / 219.35 6 47
8 8 0.00 231 15.15 277 969 5.25 / 220.32 6 -99
Average= 4.90
(KJ/cycle)

Cycle 43 GMT 14/11/2021 0: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 21 15.17 406 129 0.13 / 209.92 6 8
2 7 2009.00 40 14.63 3003 1757 1.89 / 211.68 8 45
3 13 1981.44 20 14.62 2970 868 2.76 / 212.55 6 48
4 13 1591.80 20 14.68 2464 723 3.48 / 213.27 6 56
5 13 922.12 20 14.86 1580 470 3.95 / 213.74 6 66
6 13 294.48 20 15.10 715 216 4.16 / 213.96 6 57
7 13 149.04 20 15.15 503 152 4.32 / 214.11 6 49
8 8 0.08 231 15.15 276 966 5.28 / 215.07 6 172
Average= 4.89
(KJ/cycle)

Cycle 42 GMT 9/11/2021 0:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 21 15.17 415 132 0.13 / 204.59 6 8
2 7 2008.56 40 14.63 3002 1757 1.89 / 206.35 8 46
3 13 1979.92 20 14.62 2965 867 2.76 / 207.22 6 48
4 13 1625.84 20 14.67 2512 737 3.49 / 207.95 6 56
5 13 944.32 20 14.86 1614 480 3.97 / 208.43 6 67
6 13 311.00 20 15.10 737 223 4.20 / 208.66 6 59
7 13 161.36 20 15.15 522 158 4.35 / 208.81 6 50
8 8 0.12 231 15.16 279 977 5.33 / 209.79 6 226
Average= 4.88
(KJ/cycle)

Cycle 41 GMT 4/11/2021 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 21 15.19 409 130 0.13 / 199.27 6 8
2 7 2013.28 40 14.63 3001 1756 1.89 / 201.02 8 45
3 13 1985.16 20 14.62 2969 868 2.75 / 201.89 6 48
4 13 1562.24 20 14.70 2420 711 3.47 / 202.60 6 56
5 13 973.36 20 14.85 1645 489 3.95 / 203.09 6 65
6 13 363.36 20 15.08 812 245 4.20 / 203.34 6 63
7 13 131.32 20 15.16 483 146 4.35 / 203.48 6 49
8 8 0.12 233 15.16 277 978 5.32 / 204.46 6 -99
Average= 4.87
(KJ/cycle)

Cycle 40 GMT 30/10/2021 1:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 21 15.18 414 132 0.13 / 194.04 6 8
2 7 2009.40 40 14.63 2997 1754 1.89 / 195.79 8 45
3 13 1981.12 20 14.62 2951 863 2.75 / 196.65 6 48
4 13 1594.28 20 14.69 2455 721 3.47 / 197.37 6 56
5 13 957.12 20 14.86 1622 482 3.95 / 197.86 6 67
6 13 257.24 20 15.13 655 198 4.15 / 198.05 6 56
7 13 115.92 20 15.17 451 137 4.29 / 198.19 6 47
8 8 0.12 231 15.17 270 946 5.23 / 199.14 6 -99
Average= 4.86
(KJ/cycle)

Cycle 39 GMT 25/10/2021 2:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 21 15.18 419 134 0.13 / 188.76 6 8
2 7 2010.20 40 14.63 2997 1754 1.89 / 190.51 8 45
3 13 1979.44 20 14.63 2957 865 2.75 / 191.37 6 48
4 13 1580.32 20 14.69 2445 718 3.47 / 192.09 6 56
5 13 937.96 20 14.87 1593 474 3.94 / 192.57 6 67
6 13 331.40 20 15.10 761 230 4.17 / 192.80 6 59
7 13 144.20 20 15.16 495 150 4.32 / 192.95 6 49
8 8 0.00 231 15.17 273 957 5.28 / 193.90 6 172
Average= 4.85
(KJ/cycle)

Cycle 38 GMT 20/10/2021 2:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 21 15.19 417 133 0.13 / 183.51 6 8
2 7 2008.76 40 14.64 2994 1753 1.89 / 185.26 8 45
3 13 1980.08 20 14.63 2965 868 2.75 / 186.13 6 48
4 13 1481.96 20 14.73 2313 681 3.44 / 186.81 6 58
5 13 915.96 20 14.88 1568 467 3.90 / 187.28 6 67
6 13 316.32 20 15.10 747 226 4.13 / 187.50 6 63
7 13 122.48 20 15.17 473 144 4.27 / 187.65 6 51
8 8 0.16 231 15.17 278 974 5.25 / 188.62 6 174
Average= 4.84
(KJ/cycle)

Cycle 37 GMT 15/10/2021 3:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 21 15.18 423 135 0.13 / 178.36 6 8
2 7 2011.32 40 14.64 2997 1755 1.89 / 180.12 8 45
3 13 1982.84 20 14.64 2962 867 2.76 / 180.99 6 48
4 13 1386.28 20 14.76 2192 647 3.40 / 181.63 6 59
5 13 879.64 20 14.89 1524 454 3.86 / 182.09 6 68
6 13 245.96 20 15.14 649 197 4.05 / 182.28 6 56
7 13 101.68 20 15.18 436 132 4.19 / 182.42 6 47
8 8 0.08 231 15.18 274 961 5.15 / 183.38 6 -99
Average= 4.83
(KJ/cycle)

Cycle 36 GMT 10/10/2021 3:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 21 15.17 415 132 0.13 / 173.22 6 8
2 7 2005.20 40 14.65 2990 1752 1.88 / 174.98 7 45
3 13 1976.16 20 14.65 2950 864 2.75 / 175.84 6 48
4 13 1470.80 20 14.75 2304 680 3.43 / 176.52 6 58
5 13 771.84 20 14.94 1383 413 3.84 / 176.93 6 69
6 13 195.36 20 15.15 585 177 4.02 / 177.11 6 59
7 13 91.52 20 15.18 433 131 4.15 / 177.24 6 52
8 8 0.12 229 15.17 284 987 5.14 / 178.23 6 138
Average= 4.82
(KJ/cycle)

Cycle 35 GMT 5/10/2021 4:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 21 15.16 416 132 0.13 / 168.04 6 9
2 7 2009.12 40 14.66 2993 1755 1.89 / 169.79 9 45
3 13 1980.04 20 14.65 2958 867 2.75 / 170.66 6 48
4 13 1514.92 20 14.74 2363 697 3.45 / 171.35 6 57
5 13 810.08 20 14.92 1435 428 3.88 / 171.78 6 70
6 13 181.40 20 15.14 576 174 4.05 / 171.96 6 68
7 13 37.40 20 15.19 368 112 4.17 / 172.07 6 60
8 8 0.04 229 15.16 295 1024 5.19 / 173.09 6 153
Average= 4.81
(KJ/cycle)

Cycle 34 GMT 30/ 9/2021 4:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 21 15.18 423 135 0.13 / 162.83 6 8
2 7 2003.68 40 14.65 2992 1753 1.89 / 164.59 8 45
3 13 1973.60 20 14.65 2943 862 2.75 / 165.45 6 48
4 13 1436.84 20 14.76 2261 667 3.42 / 166.12 6 59
5 13 878.52 20 14.90 1514 451 3.87 / 166.57 6 68
6 13 162.92 20 15.14 559 169 4.04 / 166.74 6 72
7 13 50.80 20 15.18 396 120 4.16 / 166.86 6 68
8 13 18.76 20 15.19 344 105 4.26 / 166.96 6 64
9 8 0.04 208 15.15 299 942 5.21 / 167.90 6 142
Average= 4.80
(KJ/cycle)

Cycle 33 GMT 25/ 9/2021 5:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 21 15.18 415 132 0.13 / 157.63 6 8
2 7 2012.40 40 14.65 2999 1757 1.89 / 159.39 8 45
3 13 1983.00 20 14.65 2965 869 2.76 / 160.26 6 48
4 13 1453.16 20 14.75 2272 670 3.43 / 160.93 6 58
5 13 859.04 20 14.91 1501 448 3.88 / 161.38 6 69
6 13 252.32 20 15.13 668 202 4.08 / 161.58 6 66
7 13 95.76 20 15.18 440 134 4.21 / 161.71 6 56
8 8 0.00 229 15.17 284 987 5.20 / 162.70 6 138
Average= 4.79
(KJ/cycle)

Cycle 32 GMT 20/ 9/2021 5:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 21 15.19 414 132 0.13 / 152.31 6 8
2 7 2011.24 40 14.66 3007 1763 1.90 / 154.07 8 45
3 13 1983.00 20 14.66 2969 871 2.77 / 154.94 6 48
4 13 1594.40 20 14.72 2464 725 3.49 / 155.67 6 56
5 13 1002.40 20 14.87 1680 500 3.99 / 156.17 6 66
6 13 237.04 20 15.14 645 195 4.19 / 156.36 6 63
7 13 128.48 20 15.18 482 146 4.33 / 156.51 6 56
8 8 0.12 233 15.18 280 990 5.32 / 157.50 6 -99
Average= 4.77
(KJ/cycle)

Cycle 31 GMT 15/ 9/2021 6:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 21 15.19 424 135 0.14 / 146.94 6 8
2 7 2008.20 40 14.66 3001 1760 1.90 / 148.69 8 45
3 13 1980.72 20 14.66 2964 869 2.76 / 149.56 6 48
4 13 1628.36 20 14.71 2507 738 3.50 / 150.30 6 56
5 13 1036.76 20 14.85 1723 512 4.01 / 150.81 6 65
6 13 304.52 20 15.11 742 224 4.24 / 151.04 6 68
7 13 107.40 20 15.18 459 139 4.38 / 151.18 6 57
8 8 -0.08 231 15.18 285 999 5.38 / 152.18 6 139
Average= 4.76
(KJ/cycle)

Cycle 30 GMT 12/ 9/2021 10:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 21 15.18 417 133 0.13 / 141.65 6 8
2 7 2008.68 40 14.67 3000 1760 1.89 / 143.41 8 45
3 13 1979.36 20 14.67 2961 869 2.76 / 144.28 6 48
4 13 1474.16 20 14.76 2306 681 3.44 / 144.96 6 58
5 13 965.00 20 14.88 1641 488 3.93 / 145.45 6 66
6 13 281.52 20 15.13 706 214 4.14 / 145.66 6 63
7 13 128.80 20 15.18 485 147 4.29 / 145.81 6 55
8 8 0.16 231 15.18 282 989 5.28 / 146.80 6 175
Average= 4.74
(KJ/cycle)

Cycle 29 GMT 9/ 9/2021 15:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 21 15.17 415 132 0.13 / 136.36 6 8
2 7 2013.64 41 14.67 3007 1809 1.94 / 138.17 8 45
3 13 1983.28 20 14.67 2962 869 2.81 / 139.04 6 49
4 13 1471.68 20 14.76 2307 681 3.49 / 139.72 6 58
5 13 888.80 20 14.91 1536 458 3.95 / 140.18 6 69
6 13 255.88 20 15.12 680 206 4.15 / 140.38 6 69
7 13 68.04 20 15.19 407 124 4.28 / 140.51 6 59
8 8 0.12 231 15.17 289 1013 5.29 / 141.52 6 -99
Average= 4.72
(KJ/cycle)

Cycle 28 GMT 6/ 9/2021 19:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 21 15.16 418 133 0.13 / 130.99 6 8
2 7 2015.04 41 14.67 3004 1807 1.94 / 132.80 8 45
3 13 1984.64 20 14.67 2966 870 2.81 / 133.67 6 48
4 13 1616.60 20 14.72 2501 736 3.55 / 134.40 6 56
5 13 916.00 20 14.89 1581 471 4.02 / 134.87 6 68
6 13 211.96 20 15.13 624 189 4.21 / 135.06 6 72
7 13 55.96 20 15.19 399 121 4.33 / 135.18 6 65
8 13 15.72 20 15.19 336 102 4.43 / 135.29 6 61
9 8 0.04 210 15.16 296 942 5.37 / 136.23 6 154
Average= 4.70
(KJ/cycle)

Cycle 27 GMT 4/ 9/2021 0:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 20 15.29 415 127 0.13 / 125.64 6 7
2 3 1540.52 1 15.05 2431 37 0.16 / 125.67 6 37
3 7 2013.68 40 14.66 3003 1761 1.92 / 127.43 37 45
4 13 1986.20 20 14.66 2972 871 2.80 / 128.31 6 48
5 13 1593.60 20 14.71 2451 721 3.52 / 129.03 6 56
6 13 945.52 20 14.88 1607 478 4.00 / 129.50 6 66
7 13 230.44 20 15.12 647 196 4.19 / 129.70 6 70
8 13 72.24 20 15.17 419 127 4.32 / 129.83 6 64
9 8 0.00 231 15.15 294 1029 5.35 / 130.86 6 143
Average= 4.67
(KJ/cycle)

Cycle 26 GMT 1/ 9/2021 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 50 15.30 399 305 0.31 / 123.78 6 9
2 3 352.68 -2 15.51 6 0 0.00 / 123.78 6 9
3 7 486.64 40 15.34 941 577 0.88 / 124.36 9 41
4 13 114.56 20 15.37 445 137 1.02 / 124.50 6 40
5 13 25.08 20 15.38 313 96 1.12 / 124.59 6 36
6 8 0.04 223 15.33 268 916 2.03 / 125.51 6 -99
Average= 4.65
(KJ/cycle)

Cycle 25 GMT 30/ 8/2021 0:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 50 15.34 389 298 0.30 / 121.89 6 9
2 7 353.24 40 15.42 737 455 0.75 / 122.35 9 26
3 13 169.16 20 15.42 496 153 0.91 / 122.50 6 29
4 13 58.96 20 15.42 347 107 1.01 / 122.61 6 28
5 8 0.04 220 15.38 257 870 1.88 / 123.48 6 -99
Average= 4.75
(KJ/cycle)

Cycle 24 GMT 27/ 8/2021 13:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 50 15.20 412 313 0.31 / 120.02 6 9
2 7 374.64 40 15.45 770 476 0.79 / 120.50 9 27
3 13 148.96 20 15.45 471 146 0.93 / 120.65 6 29
4 13 10.84 20 15.46 279 86 1.02 / 120.73 6 26
5 8 0.04 218 15.41 257 863 1.88 / 121.59 6 -99
Average= 4.86
(KJ/cycle)

Cycle 23 GMT 25/ 8/2021 2: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 50 15.35 403 309 0.31 / 114.63 6 9
2 7 2015.24 40 14.69 2998 1762 2.07 / 116.39 9 38
3 13 1985.52 20 14.67 2949 865 2.94 / 117.26 6 41
4 13 1472.48 20 14.76 2292 677 3.61 / 117.94 6 54
5 13 952.12 20 14.90 1610 480 4.09 / 118.42 6 63
6 13 236.16 20 15.17 629 191 4.28 / 118.61 6 51
7 13 130.72 20 15.20 473 144 4.43 / 118.75 6 45
8 8 0.12 233 15.21 271 960 5.39 / 119.71 6 -99
Average= 4.99
(KJ/cycle)

Cycle 22 GMT 22/ 8/2021 10:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 50 15.22 407 310 0.31 / 112.75 6 9
2 7 371.36 40 15.47 759 470 0.78 / 113.22 9 25
3 13 188.32 20 15.46 527 163 0.94 / 113.38 6 28
4 8 0.12 240 15.43 255 944 1.89 / 114.32 6 -99
Average= 4.97
(KJ/cycle)

Cycle 21 GMT 19/ 8/2021 23:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 16 15.24 403 98 0.10 / 107.24 6 7
2 10 1500.16 4 14.96 2336 140 0.24 / 107.38 6 37
3 7 2014.04 40 14.68 2996 1759 2.00 / 109.14 37 45
4 13 1985.00 20 14.68 2972 873 2.87 / 110.01 6 48
5 13 1512.24 20 14.77 2368 700 3.57 / 110.71 6 58
6 13 849.92 20 14.96 1483 444 4.01 / 111.16 6 67
7 13 254.24 20 15.18 650 197 4.21 / 111.35 6 52
8 13 116.56 20 15.23 447 136 4.35 / 111.49 6 43
9 8 -0.08 231 15.22 269 946 5.29 / 112.44 6 206
Average= 5.11
(KJ/cycle)

Cycle 20 GMT 15/ 8/2021 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 16 15.23 421 103 0.10 / 101.88 6 7
2 10 1507.60 4 14.96 2349 141 0.24 / 102.02 6 40
3 7 2006.04 40 14.69 3006 1766 2.01 / 103.79 40 46
4 13 1978.72 20 14.69 2971 873 2.88 / 104.66 6 49
5 13 1556.28 20 14.76 2419 714 3.60 / 105.37 6 57
6 13 855.40 20 14.95 1490 446 4.04 / 105.82 6 67
7 13 291.48 20 15.17 705 214 4.26 / 106.03 6 56
8 13 140.48 20 15.21 490 149 4.40 / 106.18 6 48
9 8 0.00 231 15.22 274 963 5.37 / 107.14 6 202
Average= 5.10
(KJ/cycle)

Cycle 19 GMT 10/ 8/2021 1:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 16 15.24 418 102 0.10 / 96.47 6 7
2 10 1503.80 3 14.97 2364 106 0.21 / 96.58 6 40
3 7 2010.32 40 14.69 3009 1768 1.98 / 98.35 40 46
4 13 1980.48 20 14.69 2975 874 2.85 / 99.22 6 49
5 13 1548.24 20 14.76 2411 712 3.56 / 99.93 6 58
6 13 952.32 20 14.92 1615 482 4.04 / 100.41 6 67
7 13 376.00 20 15.13 831 251 4.30 / 100.66 6 64
8 13 104.52 20 15.23 441 134 4.43 / 100.80 6 48
9 8 0.08 231 15.22 278 977 5.41 / 101.78 6 -99
Average= 5.09
(KJ/cycle)

Cycle 18 GMT 5/ 8/2021 2:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 16 15.25 415 101 0.10 / 91.08 6 7
2 10 1506.56 4 14.97 2360 141 0.24 / 91.22 6 38
3 10 1512.16 3 14.99 2349 106 0.35 / 91.32 6 39
4 7 2009.08 40 14.69 3005 1766 2.11 / 93.09 39 46
5 13 1977.32 20 14.69 2974 874 2.99 / 93.96 6 49
6 13 1417.64 20 14.81 2242 664 3.65 / 94.63 6 60
7 13 859.88 20 14.95 1498 448 4.10 / 95.08 6 69
8 13 254.92 20 15.18 662 201 4.30 / 95.28 6 58
9 13 109.60 20 15.23 449 137 4.44 / 95.41 6 48
10 8 0.04 229 15.23 274 956 5.39 / 96.37 6 153
Average= 5.07
(KJ/cycle)

Cycle 17 GMT 31/ 7/2021 3:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 16 15.26 407 99 0.10 / 85.61 6 7
2 10 1500.00 4 14.97 2354 141 0.24 / 85.75 6 37
3 10 1505.44 3 15.00 2359 106 0.35 / 85.86 6 38
4 7 2012.76 40 14.71 3008 1770 2.12 / 87.63 38 45
5 13 1982.60 20 14.70 2982 877 2.99 / 88.50 6 48
6 13 1471.12 20 14.80 2311 684 3.68 / 89.19 6 59
7 13 923.40 20 14.94 1576 471 4.15 / 89.66 6 66
8 13 312.64 20 15.17 737 224 4.37 / 89.88 6 56
9 13 127.88 20 15.23 471 143 4.52 / 90.03 6 46
10 8 0.12 231 15.24 270 951 5.47 / 90.98 6 -99
Average= 5.05
(KJ/cycle)

Cycle 16 GMT 26/ 7/2021 4:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 16 15.25 419 102 0.10 / 80.21 6 7
2 10 1506.80 4 14.97 2355 141 0.24 / 80.35 6 39
3 7 2014.76 40 14.70 3019 1775 2.02 / 82.13 39 46
4 13 1985.44 20 14.70 2982 877 2.90 / 83.00 6 49
5 13 1513.76 20 14.79 2368 700 3.60 / 83.70 6 58
6 13 961.64 20 14.93 1631 487 4.08 / 84.19 6 66
7 13 289.08 20 15.19 701 213 4.30 / 84.40 6 53
8 13 145.72 20 15.23 493 150 4.45 / 84.55 6 45
9 8 0.08 231 15.24 272 958 5.40 / 85.51 6 241
Average= 5.03
(KJ/cycle)

Cycle 15 GMT 21/ 7/2021 5:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 16 15.26 410 100 0.10 / 74.81 6 7
2 10 1502.84 4 14.98 2349 141 0.24 / 74.95 6 40
3 7 2016.00 40 14.70 3019 1775 2.02 / 76.73 40 46
4 13 1987.40 20 14.71 2983 878 2.89 / 77.60 6 49
5 13 1485.64 20 14.79 2334 690 3.58 / 78.29 6 59
6 13 930.76 20 14.94 1599 478 4.06 / 78.77 6 67
7 13 291.28 20 15.18 714 217 4.28 / 78.99 6 57
8 13 146.48 20 15.23 502 153 4.43 / 79.14 6 48
9 8 0.12 231 15.24 274 965 5.40 / 80.11 6 -99
Average= 5.01
(KJ/cycle)

Cycle 14 GMT 16/ 7/2021 6:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 16 15.24 426 104 0.10 / 69.47 6 7
2 10 1500.40 4 14.95 2349 140 0.24 / 69.61 6 42
3 7 2004.56 40 14.72 3001 1767 2.01 / 71.38 42 46
4 13 1973.44 20 14.72 2971 875 2.89 / 72.25 6 50
5 13 1432.80 20 14.81 2263 670 3.56 / 72.92 6 60
6 13 915.60 20 14.95 1578 472 4.03 / 73.39 6 67
7 13 268.16 20 15.20 675 205 4.23 / 73.60 6 56
8 13 121.64 20 15.24 459 140 4.37 / 73.74 6 47
9 8 0.00 231 15.24 276 972 5.34 / 74.71 6 -99
Average= 4.98
(KJ/cycle)

Cycle 13 GMT 11/ 7/2021 7:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 16 15.24 417 102 0.10 / 64.13 6 8
2 10 1504.20 4 14.93 2371 142 0.24 / 64.28 6 43
3 7 2007.40 40 14.72 3009 1772 2.01 / 66.05 43 46
4 13 1976.56 20 14.72 2977 876 2.89 / 66.92 6 49
5 13 1462.28 20 14.82 2295 680 3.57 / 67.60 6 59
6 13 773.04 20 15.00 1390 417 3.99 / 68.02 6 70
7 13 215.08 20 15.20 618 188 4.18 / 68.21 6 65
8 13 102.60 20 15.24 457 139 4.32 / 68.35 6 59
9 8 0.12 229 15.23 292 1018 5.33 / 69.37 6 186
Average= 4.95
(KJ/cycle)

Cycle 12 GMT 6/ 7/2021 8:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 16 15.24 428 104 0.10 / 58.78 6 8
2 10 1507.04 4 14.96 2366 142 0.25 / 58.93 6 43
3 7 2011.60 40 14.72 3013 1774 2.02 / 60.70 43 46
4 13 1980.68 20 14.73 2974 876 2.90 / 61.58 6 49
5 13 1440.12 20 14.83 2267 672 3.57 / 62.25 6 60
6 13 942.72 20 14.94 1610 481 4.05 / 62.73 6 68
7 13 149.68 20 15.22 528 161 4.21 / 62.89 6 69
8 13 38.28 20 15.25 369 113 4.32 / 63.00 6 64
9 8 0.00 227 15.22 298 1030 5.35 / 64.03 6 150
Average= 4.93
(KJ/cycle)

Cycle 11 GMT 1/ 7/2021 9:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 16 15.25 412 101 0.10 / 53.50 6 8
2 10 1500.12 3 14.96 2370 106 0.21 / 53.60 6 43
3 7 2010.84 40 14.73 3012 1775 1.98 / 55.38 43 46
4 13 1980.96 20 14.73 2971 875 2.86 / 56.25 6 49
5 13 1502.04 20 14.81 2351 696 3.55 / 56.95 6 58
6 13 798.28 20 15.00 1424 427 3.98 / 57.38 6 70
7 13 169.60 20 15.22 561 171 4.15 / 57.55 6 68
8 13 29.92 20 15.26 354 108 4.26 / 57.66 6 60
9 8 -0.04 227 15.22 296 1023 5.28 / 58.68 6 155
Average= 4.89
(KJ/cycle)

Cycle 10 GMT 26/ 6/2021 10:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 16 15.25 431 105 0.11 / 48.23 6 8
2 10 1505.84 3 14.97 2365 106 0.21 / 48.33 6 42
3 7 2003.44 40 14.74 3010 1775 1.99 / 50.11 42 46
4 13 1973.80 20 14.74 2960 873 2.86 / 50.98 6 49
5 13 1442.96 20 14.83 2281 677 3.54 / 51.66 6 59
6 13 877.16 20 14.97 1515 454 3.99 / 52.11 6 68
7 13 165.20 20 15.23 547 167 4.16 / 52.28 6 63
8 13 26.76 20 15.27 344 105 4.26 / 52.38 6 55
9 8 0.00 229 15.23 291 1015 5.28 / 53.40 6 201
Average= 4.85
(KJ/cycle)

Cycle 9 GMT 21/ 6/2021 11:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 16 15.25 419 102 0.10 / 42.95 6 8
2 10 1506.20 3 14.97 2368 106 0.21 / 43.05 6 42
3 7 2004.84 40 14.74 2998 1768 1.98 / 44.82 42 46
4 13 1974.32 20 14.74 2958 872 2.85 / 45.69 6 48
5 13 1398.76 20 14.84 2213 657 3.51 / 46.35 6 60
6 13 876.44 20 14.97 1521 455 3.96 / 46.81 6 68
7 13 192.20 20 15.22 594 181 4.14 / 46.99 6 67
8 13 18.32 20 15.27 340 104 4.25 / 47.09 6 58
9 8 -0.04 229 15.23 296 1032 5.28 / 48.12 6 151
Average= 4.81
(KJ/cycle)

Cycle 8 GMT 16/ 6/2021 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 16 15.25 420 102 0.10 / 37.57 6 8
2 10 1505.40 3 14.97 2355 106 0.21 / 37.67 6 42
3 7 2010.20 41 14.74 3009 1818 2.03 / 39.49 42 46
4 13 1981.36 20 14.75 2965 875 2.90 / 40.36 6 48
5 13 1552.68 20 14.81 2421 717 3.62 / 41.08 6 57
6 13 877.04 20 14.98 1516 454 4.07 / 41.54 6 67
7 13 139.24 20 15.24 508 155 4.23 / 41.69 6 62
8 13 30.20 20 15.27 356 109 4.34 / 41.80 6 57
9 8 -0.04 231 15.23 297 1045 5.38 / 42.84 6 186
Average= 4.76
(KJ/cycle)

Cycle 7 GMT 11/ 6/2021 13:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 16 15.26 412 101 0.10 / 32.21 6 8
2 10 1502.08 3 14.97 2352 106 0.21 / 32.32 6 40
3 7 2010.28 40 14.76 3006 1775 1.98 / 34.09 40 46
4 13 1981.40 20 14.75 2976 878 2.86 / 34.97 6 49
5 13 1457.04 20 14.83 2297 681 3.54 / 35.65 6 59
6 13 895.60 20 14.98 1550 464 4.00 / 36.12 6 68
7 13 209.20 20 15.21 618 188 4.19 / 36.30 6 68
8 13 50.00 20 15.26 388 118 4.31 / 36.42 6 62
9 8 -0.04 231 15.23 296 1041 5.35 / 37.46 6 154
Average= 4.68
(KJ/cycle)

Cycle 6 GMT 6/ 6/2021 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 16 15.26 418 102 0.10 / 26.97 6 8
2 10 1505.12 3 14.98 2358 106 0.21 / 27.08 6 38
3 7 2004.80 40 14.76 2998 1770 1.98 / 28.85 38 46
4 13 1975.32 20 14.75 2959 873 2.85 / 29.72 6 48
5 13 1502.48 20 14.83 2347 696 3.55 / 30.42 6 58
6 13 827.40 20 15.00 1456 437 3.98 / 30.86 6 69
7 13 160.40 20 15.24 542 165 4.15 / 31.02 6 63
8 13 24.40 20 15.28 338 103 4.25 / 31.12 6 56
9 8 0.00 231 15.25 280 986 5.24 / 32.11 6 135
Average= 4.59
(KJ/cycle)

Cycle 5 GMT 1/ 6/2021 15:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 16 15.26 420 103 0.10 / 21.78 6 8
2 10 1501.64 3 14.99 2363 106 0.21 / 21.89 6 38
3 7 2012.80 40 14.76 3013 1779 1.99 / 23.67 38 45
4 13 1983.84 20 14.76 2972 877 2.87 / 24.54 6 48
5 13 1372.96 20 14.86 2179 648 3.51 / 25.19 6 60
6 13 799.24 20 15.02 1397 420 3.93 / 25.61 6 66
7 13 161.28 20 15.24 529 161 4.09 / 25.77 6 60
8 13 25.00 20 15.28 334 102 4.20 / 25.88 6 54
9 8 0.08 231 15.25 283 997 5.19 / 26.87 6 153
Average= 4.48
(KJ/cycle)

Cycle 4 GMT 27/ 5/2021 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 16 15.26 408 100 0.10 / 16.48 6 8
2 10 1503.64 3 15.01 2347 106 0.21 / 16.58 6 32
3 7 2007.68 40 14.77 2989 1766 1.97 / 18.35 32 46
4 13 1978.12 20 14.77 2939 868 2.84 / 19.22 6 48
5 13 1576.60 20 14.82 2428 720 3.56 / 19.94 6 57
6 13 885.68 20 15.00 1518 455 4.01 / 20.39 6 67
7 13 195.44 20 15.24 583 178 4.19 / 20.57 6 64
8 13 42.64 20 15.28 360 110 4.30 / 20.68 6 56
9 8 0.00 233 15.25 281 998 5.30 / 21.68 6 172
Average= 4.34
(KJ/cycle)

Cycle 3 GMT 22/ 5/2021 17:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 16 15.25 410 100 0.10 / 11.21 6 8
2 10 1506.04 3 15.00 2347 106 0.21 / 11.32 6 33
3 7 2012.16 40 14.79 2977 1761 1.97 / 13.08 33 45
4 13 1982.56 20 14.78 2937 868 2.84 / 13.94 6 48
5 13 1473.48 20 14.86 2300 684 3.52 / 14.63 6 58
6 13 909.44 20 14.99 1538 461 3.98 / 15.09 6 67
7 13 254.76 20 15.21 658 200 4.18 / 15.29 6 65
8 13 25.60 20 15.28 334 102 4.28 / 15.39 6 58
9 8 0.12 233 15.25 278 988 5.27 / 16.38 6 153
Average= 4.09
(KJ/cycle)

Cycle 2 GMT 17/ 5/2021 18:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 2004.80 4 14.83 3010 179 0.18 / 6.47 6 24
2 7 2008.32 40 14.69 2974 1748 1.93 / 8.22 24 39
3 13 1872.40 20 14.72 2797 823 2.75 / 9.04 6 44
4 13 1200.60 20 14.87 1935 575 3.32 / 9.62 6 59
5 13 623.44 20 15.06 1163 350 3.68 / 9.97 6 68
6 13 49.12 20 15.26 365 111 3.79 / 10.08 6 59
7 8 0.08 246 15.23 275 1030 4.82 / 11.11 6 135
Average= 3.70
(KJ/cycle)

Cycle 1 GMT 17/ 5/2021 7:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 2004.08 4 14.82 3025 179 0.18 / 1.60 6 23
2 7 2007.56 40 14.67 2976 1746 1.93 / 3.35 23 38
3 13 1838.80 20 14.70 2768 814 2.74 / 4.16 6 44
4 13 1296.00 20 14.84 2055 610 3.35 / 4.77 6 57
5 13 705.68 20 15.03 1268 381 3.73 / 5.15 6 67
6 13 52.20 20 15.28 366 112 3.84 / 5.26 6 58
7 8 0.04 249 15.25 271 1029 4.87 / 6.29 6 168
Average= 3.15
(KJ/cycle)

Cycle 0 GMT 16/ 5/2021 21:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 75.08 41 15.55 344 219 0.22 / 0.22 7 17
2 13 96.24 20 15.54 370 115 0.33 / 0.33 6 19
3 13 79.76 20 15.52 349 108 0.44 / 0.44 6 21
4 13 32.08 20 15.52 285 88 0.53 / 0.53 6 22
5 8 0.12 248 15.47 232 890 1.42 / 1.42 6 -99
Average= 1.42
(KJ/cycle)