SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 36 | 14.88 | 437 | 234 | 0.23 / 802.32 | 6 | 12 |
2 | 7 | 2005.32 | 40 | 14.44 | 3085 | 1782 | 2.02 / 804.10 | 12 | 47 |
3 | 13 | 1920.88 | 20 | 14.43 | 2972 | 858 | 2.87 / 804.96 | 6 | 51 |
4 | 13 | 1603.40 | 20 | 14.41 | 2564 | 739 | 3.61 / 805.70 | 6 | 59 |
5 | 13 | 942.16 | 20 | 14.57 | 1656 | 483 | 4.10 / 806.18 | 6 | 66 |
6 | 13 | 274.00 | 20 | 14.82 | 721 | 214 | 4.31 / 806.39 | 6 | 61 |
7 | 13 | 16.44 | 20 | 14.91 | 327 | 98 | 4.41 / 806.49 | 6 | 48 |
8 | 8 | -0.04 | 246 | 14.86 | 295 | 1078 | 5.48 / 807.57 | 6 | -99 |
Average= | 8.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 36 | 14.89 | 427 | 229 | 0.23 / 796.91 | 6 | 12 |
2 | 7 | 2005.60 | 40 | 14.44 | 3080 | 1779 | 2.01 / 798.69 | 12 | 49 |
3 | 13 | 1930.20 | 20 | 14.41 | 3011 | 868 | 2.88 / 799.56 | 6 | 53 |
4 | 13 | 1515.60 | 20 | 14.43 | 2434 | 702 | 3.58 / 800.26 | 6 | 60 |
5 | 13 | 891.04 | 20 | 14.58 | 1575 | 459 | 4.04 / 800.72 | 6 | 64 |
6 | 13 | 234.40 | 20 | 14.83 | 669 | 198 | 4.24 / 800.92 | 6 | 59 |
7 | 8 | 0.20 | 265 | 14.87 | 296 | 1166 | 5.40 / 802.08 | 6 | -99 |
Average= | 8.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 36 | 14.88 | 429 | 230 | 0.23 / 791.47 | 6 | 13 |
2 | 7 | 2018.08 | 40 | 14.43 | 3105 | 1792 | 2.02 / 793.27 | 13 | 49 |
3 | 13 | 1936.56 | 20 | 14.40 | 3012 | 867 | 2.89 / 794.13 | 6 | 52 |
4 | 13 | 1418.84 | 20 | 14.46 | 2302 | 666 | 3.56 / 794.80 | 6 | 60 |
5 | 13 | 1012.96 | 20 | 14.54 | 1743 | 507 | 4.06 / 795.31 | 6 | 65 |
6 | 13 | 244.40 | 20 | 14.83 | 679 | 201 | 4.26 / 795.51 | 6 | 60 |
7 | 13 | 32.64 | 20 | 14.91 | 352 | 105 | 4.37 / 795.61 | 6 | 51 |
8 | 8 | 0.08 | 246 | 14.87 | 292 | 1068 | 5.44 / 796.68 | 6 | -99 |
Average= | 8.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 36 | 14.89 | 435 | 233 | 0.23 / 785.89 | 6 | 11 |
2 | 7 | 2004.12 | 41 | 14.44 | 3066 | 1815 | 2.05 / 787.71 | 11 | 48 |
3 | 13 | 1924.20 | 20 | 14.43 | 2952 | 852 | 2.90 / 788.56 | 6 | 51 |
4 | 13 | 1598.64 | 20 | 14.42 | 2546 | 734 | 3.63 / 789.30 | 6 | 58 |
5 | 13 | 1044.56 | 20 | 14.53 | 1779 | 517 | 4.15 / 789.81 | 6 | 64 |
6 | 13 | 364.32 | 20 | 14.77 | 856 | 253 | 4.40 / 790.07 | 6 | 65 |
7 | 13 | 15.16 | 20 | 14.91 | 324 | 97 | 4.50 / 790.16 | 6 | 48 |
8 | 8 | 0.04 | 246 | 14.86 | 296 | 1082 | 5.58 / 791.24 | 6 | -99 |
Average= | 8.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 36 | 14.88 | 424 | 227 | 0.23 / 780.38 | 6 | 10 |
2 | 7 | 2008.68 | 41 | 14.44 | 3086 | 1827 | 2.05 / 782.20 | 10 | 49 |
3 | 13 | 1929.92 | 20 | 14.42 | 2998 | 865 | 2.92 / 783.07 | 6 | 54 |
4 | 13 | 1613.28 | 20 | 14.41 | 2579 | 743 | 3.66 / 783.81 | 6 | 59 |
5 | 13 | 943.96 | 20 | 14.56 | 1662 | 484 | 4.15 / 784.29 | 6 | 66 |
6 | 13 | 190.92 | 20 | 14.85 | 605 | 180 | 4.33 / 784.47 | 6 | 56 |
7 | 13 | 47.28 | 20 | 14.91 | 377 | 112 | 4.44 / 784.59 | 6 | 50 |
8 | 8 | 0.00 | 244 | 14.87 | 296 | 1074 | 5.51 / 785.66 | 6 | 150 |
Average= | 9.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 36 | 14.88 | 431 | 231 | 0.23 / 774.93 | 6 | 14 |
2 | 7 | 2003.08 | 40 | 14.44 | 3068 | 1772 | 2.00 / 776.71 | 14 | 48 |
3 | 13 | 1917.92 | 20 | 14.42 | 2980 | 859 | 2.86 / 777.57 | 6 | 52 |
4 | 13 | 1517.28 | 20 | 14.43 | 2449 | 707 | 3.57 / 778.27 | 6 | 60 |
5 | 13 | 863.12 | 20 | 14.59 | 1544 | 451 | 4.02 / 778.72 | 6 | 64 |
6 | 13 | 329.88 | 20 | 14.79 | 805 | 238 | 4.26 / 778.96 | 6 | 61 |
7 | 13 | 51.04 | 20 | 14.90 | 385 | 115 | 4.37 / 779.08 | 6 | 51 |
8 | 8 | 0.04 | 244 | 14.86 | 296 | 1073 | 5.45 / 780.15 | 6 | 180 |
Average= | 9.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 36 | 14.90 | 433 | 232 | 0.23 / 769.32 | 6 | 11 |
2 | 7 | 2004.28 | 40 | 14.45 | 3074 | 1777 | 2.01 / 771.10 | 11 | 47 |
3 | 13 | 1918.28 | 20 | 14.43 | 2979 | 860 | 2.87 / 771.96 | 6 | 50 |
4 | 13 | 1714.92 | 20 | 14.40 | 2708 | 780 | 3.65 / 772.74 | 6 | 56 |
5 | 13 | 957.68 | 20 | 14.56 | 1685 | 491 | 4.14 / 773.23 | 6 | 65 |
6 | 13 | 408.40 | 20 | 14.76 | 923 | 272 | 4.41 / 773.50 | 6 | 65 |
7 | 13 | 37.56 | 20 | 14.91 | 372 | 111 | 4.52 / 773.61 | 6 | 53 |
8 | 8 | 0.12 | 246 | 14.86 | 299 | 1093 | 5.62 / 774.70 | 6 | -99 |
Average= | 9.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 36 | 14.89 | 429 | 230 | 0.23 / 763.79 | 6 | 10 |
2 | 7 | 2004.44 | 40 | 14.44 | 3091 | 1785 | 2.02 / 765.57 | 10 | 48 |
3 | 13 | 1925.84 | 20 | 14.42 | 2999 | 865 | 2.88 / 766.44 | 6 | 53 |
4 | 13 | 1615.28 | 20 | 14.41 | 2592 | 747 | 3.63 / 767.18 | 6 | 59 |
5 | 13 | 1054.04 | 20 | 14.52 | 1824 | 530 | 4.16 / 767.71 | 6 | 67 |
6 | 13 | 182.52 | 20 | 14.86 | 595 | 177 | 4.33 / 767.89 | 6 | 59 |
7 | 13 | 40.56 | 20 | 14.91 | 374 | 112 | 4.45 / 768.00 | 6 | 51 |
8 | 8 | 0.08 | 246 | 14.87 | 297 | 1086 | 5.53 / 769.09 | 6 | -99 |
Average= | 9.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 36 | 14.89 | 420 | 225 | 0.23 / 758.35 | 6 | 10 |
2 | 7 | 2005.88 | 40 | 14.44 | 3087 | 1783 | 2.01 / 760.13 | 10 | 48 |
3 | 13 | 1924.64 | 20 | 14.42 | 2987 | 861 | 2.87 / 760.99 | 6 | 53 |
4 | 13 | 1521.12 | 20 | 14.43 | 2462 | 711 | 3.58 / 761.70 | 6 | 60 |
5 | 13 | 984.40 | 20 | 14.55 | 1713 | 498 | 4.08 / 762.20 | 6 | 65 |
6 | 13 | 206.56 | 20 | 14.84 | 634 | 188 | 4.27 / 762.39 | 6 | 59 |
7 | 8 | 0.04 | 265 | 14.87 | 296 | 1166 | 5.43 / 763.56 | 6 | -99 |
Average= | 9.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 36 | 14.89 | 436 | 234 | 0.23 / 752.99 | 6 | 15 |
2 | 7 | 2005.04 | 40 | 14.45 | 3063 | 1770 | 2.00 / 754.76 | 15 | 47 |
3 | 13 | 1924.72 | 20 | 14.43 | 2967 | 856 | 2.86 / 755.62 | 6 | 51 |
4 | 13 | 1603.92 | 20 | 14.42 | 2555 | 737 | 3.60 / 756.36 | 6 | 57 |
5 | 13 | 851.84 | 20 | 14.61 | 1533 | 448 | 4.05 / 756.80 | 6 | 64 |
6 | 13 | 110.84 | 20 | 14.90 | 479 | 143 | 4.19 / 756.95 | 6 | 53 |
7 | 13 | 28.52 | 20 | 14.92 | 353 | 105 | 4.29 / 757.05 | 6 | 48 |
8 | 8 | -0.08 | 244 | 14.88 | 295 | 1071 | 5.36 / 758.12 | 6 | 139 |
Average= | 9.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 36 | 14.87 | 429 | 230 | 0.23 / 747.30 | 6 | 13 |
2 | 7 | 2010.84 | 40 | 14.45 | 3098 | 1791 | 2.02 / 749.09 | 13 | 51 |
3 | 13 | 1924.20 | 20 | 14.42 | 2996 | 864 | 2.88 / 749.96 | 6 | 53 |
4 | 13 | 1723.72 | 20 | 14.39 | 2735 | 787 | 3.67 / 750.74 | 6 | 58 |
5 | 13 | 1160.20 | 20 | 14.50 | 1946 | 564 | 4.24 / 751.31 | 6 | 64 |
6 | 13 | 354.72 | 20 | 14.79 | 844 | 250 | 4.49 / 751.56 | 6 | 63 |
7 | 13 | 58.68 | 20 | 14.90 | 396 | 118 | 4.60 / 751.68 | 6 | 54 |
8 | 8 | 0.12 | 246 | 14.87 | 296 | 1083 | 5.69 / 752.76 | 6 | 146 |
Average= | 9.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 36 | 14.88 | 428 | 229 | 0.23 / 741.52 | 6 | 11 |
2 | 7 | 2003.64 | 40 | 14.45 | 3083 | 1782 | 2.01 / 743.31 | 11 | 48 |
3 | 13 | 1924.16 | 20 | 14.42 | 2997 | 864 | 2.88 / 744.17 | 6 | 53 |
4 | 13 | 1520.64 | 20 | 14.44 | 2455 | 709 | 3.58 / 744.88 | 6 | 61 |
5 | 13 | 1081.40 | 20 | 14.52 | 1858 | 540 | 4.12 / 745.42 | 6 | 65 |
6 | 13 | 865.64 | 20 | 14.57 | 1526 | 445 | 4.57 / 745.86 | 6 | 64 |
7 | 13 | 47.32 | 20 | 14.90 | 380 | 113 | 4.68 / 745.98 | 6 | 51 |
8 | 8 | 0.08 | 250 | 14.85 | 295 | 1095 | 5.78 / 747.07 | 6 | -99 |
Average= | 9.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 36 | 14.89 | 428 | 229 | 0.23 / 735.94 | 6 | 10 |
2 | 7 | 2006.56 | 40 | 14.45 | 3086 | 1784 | 2.01 / 737.72 | 10 | 48 |
3 | 13 | 1921.08 | 20 | 14.44 | 2981 | 861 | 2.87 / 738.58 | 6 | 52 |
4 | 13 | 1605.36 | 20 | 14.42 | 2564 | 739 | 3.61 / 739.32 | 6 | 57 |
5 | 13 | 961.12 | 20 | 14.57 | 1688 | 492 | 4.11 / 739.81 | 6 | 67 |
6 | 13 | 406.12 | 20 | 14.76 | 920 | 272 | 4.38 / 740.08 | 6 | 65 |
7 | 13 | 38.08 | 20 | 14.91 | 366 | 109 | 4.49 / 740.19 | 6 | 49 |
8 | 8 | -0.04 | 248 | 14.86 | 299 | 1102 | 5.59 / 741.29 | 6 | -99 |
Average= | 9.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 36 | 14.88 | 427 | 229 | 0.23 / 730.40 | 6 | 11 |
2 | 7 | 2010.40 | 40 | 14.45 | 3086 | 1784 | 2.01 / 732.19 | 11 | 49 |
3 | 13 | 1928.92 | 20 | 14.43 | 2983 | 861 | 2.87 / 733.05 | 6 | 53 |
4 | 13 | 1598.36 | 20 | 14.43 | 2536 | 732 | 3.61 / 733.78 | 6 | 58 |
5 | 13 | 1055.80 | 20 | 14.54 | 1791 | 521 | 4.13 / 734.30 | 6 | 65 |
6 | 13 | 278.20 | 20 | 14.82 | 734 | 218 | 4.34 / 734.52 | 6 | 60 |
7 | 13 | 20.08 | 20 | 14.92 | 337 | 101 | 4.44 / 734.62 | 6 | 47 |
8 | 8 | 0.04 | 246 | 14.88 | 297 | 1087 | 5.53 / 735.71 | 6 | -99 |
Average= | 9.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 36 | 14.89 | 451 | 242 | 0.24 / 724.80 | 6 | 15 |
2 | 7 | 2010.40 | 40 | 14.44 | 3087 | 1783 | 2.02 / 726.58 | 15 | 50 |
3 | 13 | 1924.04 | 20 | 14.43 | 2978 | 859 | 2.88 / 727.44 | 6 | 53 |
4 | 13 | 1521.88 | 20 | 14.44 | 2445 | 706 | 3.59 / 728.14 | 6 | 59 |
5 | 13 | 983.28 | 20 | 14.56 | 1709 | 498 | 4.09 / 728.64 | 6 | 67 |
6 | 13 | 523.40 | 20 | 14.71 | 1074 | 316 | 4.40 / 728.96 | 6 | 66 |
7 | 13 | 37.76 | 20 | 14.90 | 369 | 110 | 4.51 / 729.07 | 6 | 52 |
8 | 8 | 0.08 | 246 | 14.86 | 303 | 1108 | 5.62 / 730.17 | 6 | 154 |
Average= | 9.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 36 | 14.89 | 429 | 230 | 0.23 / 719.30 | 6 | 13 |
2 | 7 | 2013.36 | 40 | 14.44 | 3094 | 1787 | 2.02 / 721.09 | 13 | 49 |
3 | 13 | 1919.76 | 20 | 14.43 | 2988 | 862 | 2.88 / 721.95 | 6 | 53 |
4 | 13 | 1500.68 | 20 | 14.45 | 2418 | 699 | 3.58 / 722.65 | 6 | 58 |
5 | 13 | 1056.08 | 20 | 14.54 | 1805 | 525 | 4.10 / 723.17 | 6 | 65 |
6 | 13 | 182.44 | 20 | 14.87 | 594 | 177 | 4.28 / 723.35 | 6 | 55 |
7 | 13 | 40.72 | 20 | 14.92 | 374 | 112 | 4.39 / 723.46 | 6 | 50 |
8 | 8 | 0.04 | 246 | 14.87 | 299 | 1094 | 5.49 / 724.55 | 6 | -99 |
Average= | 9.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 36 | 14.90 | 437 | 234 | 0.23 / 713.62 | 6 | 12 |
2 | 7 | 2018.92 | 40 | 14.45 | 3102 | 1793 | 2.03 / 715.41 | 12 | 50 |
3 | 13 | 1945.08 | 20 | 14.43 | 3022 | 872 | 2.90 / 716.28 | 6 | 51 |
4 | 13 | 1523.92 | 20 | 14.45 | 2457 | 710 | 3.61 / 716.99 | 6 | 60 |
5 | 13 | 1198.84 | 20 | 14.49 | 1999 | 579 | 4.19 / 717.57 | 6 | 64 |
6 | 13 | 402.08 | 20 | 14.77 | 911 | 269 | 4.46 / 717.84 | 6 | 66 |
7 | 13 | 37.84 | 20 | 14.91 | 373 | 111 | 4.57 / 717.95 | 6 | 49 |
8 | 8 | 0.12 | 248 | 14.87 | 303 | 1117 | 5.69 / 719.07 | 6 | -99 |
Average= | 9.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 36 | 14.88 | 434 | 232 | 0.23 / 708.08 | 6 | 13 |
2 | 7 | 2010.20 | 40 | 14.46 | 3080 | 1781 | 2.01 / 709.86 | 13 | 49 |
3 | 13 | 1922.60 | 20 | 14.44 | 2977 | 860 | 2.87 / 710.72 | 6 | 53 |
4 | 13 | 1722.92 | 20 | 14.41 | 2710 | 781 | 3.65 / 711.50 | 6 | 58 |
5 | 13 | 1045.40 | 20 | 14.55 | 1794 | 522 | 4.18 / 712.02 | 6 | 65 |
6 | 13 | 172.72 | 20 | 14.88 | 576 | 171 | 4.35 / 712.19 | 6 | 57 |
7 | 13 | 21.68 | 20 | 14.94 | 344 | 103 | 4.45 / 712.29 | 6 | 44 |
8 | 8 | 0.24 | 246 | 14.89 | 297 | 1088 | 5.54 / 713.38 | 6 | -99 |
Average= | 9.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 36 | 14.89 | 422 | 226 | 0.23 / 702.54 | 6 | 11 |
2 | 7 | 2015.20 | 40 | 14.44 | 3102 | 1792 | 2.02 / 704.33 | 11 | 49 |
3 | 13 | 1926.96 | 20 | 14.43 | 3007 | 868 | 2.89 / 705.20 | 6 | 52 |
4 | 13 | 1508.80 | 20 | 14.45 | 2437 | 704 | 3.59 / 705.90 | 6 | 60 |
5 | 13 | 1070.56 | 20 | 14.54 | 1827 | 531 | 4.12 / 706.43 | 6 | 64 |
6 | 13 | 267.44 | 20 | 14.83 | 719 | 213 | 4.33 / 706.65 | 6 | 60 |
7 | 13 | 36.52 | 20 | 14.92 | 363 | 108 | 4.44 / 706.76 | 6 | 47 |
8 | 8 | 0.04 | 246 | 14.87 | 297 | 1086 | 5.53 / 707.84 | 6 | -99 |
Average= | 9.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 36 | 14.90 | 429 | 230 | 0.23 / 697.15 | 6 | 12 |
2 | 7 | 2010.04 | 40 | 14.45 | 3093 | 1788 | 2.02 / 698.94 | 12 | 50 |
3 | 13 | 1931.52 | 20 | 14.43 | 3009 | 868 | 2.89 / 699.81 | 6 | 54 |
4 | 13 | 1422.04 | 20 | 14.47 | 2325 | 673 | 3.56 / 700.48 | 6 | 62 |
5 | 13 | 895.16 | 20 | 14.59 | 1597 | 466 | 4.03 / 700.95 | 6 | 67 |
6 | 13 | 222.24 | 20 | 14.85 | 655 | 195 | 4.22 / 701.14 | 6 | 59 |
7 | 8 | 0.12 | 265 | 14.88 | 297 | 1171 | 5.39 / 702.31 | 6 | -99 |
Average= | 9.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 36 | 14.91 | 430 | 231 | 0.23 / 691.68 | 6 | 15 |
2 | 7 | 2007.84 | 40 | 14.47 | 3065 | 1774 | 2.00 / 693.46 | 15 | 46 |
3 | 13 | 1930.32 | 20 | 14.45 | 2987 | 863 | 2.87 / 694.32 | 6 | 51 |
4 | 13 | 1725.60 | 20 | 14.41 | 2708 | 780 | 3.65 / 695.10 | 6 | 57 |
5 | 13 | 941.80 | 20 | 14.59 | 1648 | 481 | 4.13 / 695.58 | 6 | 65 |
6 | 13 | 215.56 | 20 | 14.87 | 635 | 189 | 4.32 / 695.77 | 6 | 57 |
7 | 8 | 0.08 | 267 | 14.89 | 290 | 1153 | 5.47 / 696.92 | 6 | -99 |
Average= | 9.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 36 | 14.91 | 419 | 225 | 0.22 / 686.27 | 6 | 12 |
2 | 7 | 2007.92 | 40 | 14.46 | 3095 | 1790 | 2.02 / 688.06 | 12 | 49 |
3 | 13 | 1912.60 | 20 | 14.44 | 2977 | 860 | 2.87 / 688.92 | 6 | 53 |
4 | 13 | 1712.60 | 20 | 14.41 | 2703 | 779 | 3.65 / 689.70 | 6 | 58 |
5 | 13 | 847.44 | 20 | 14.62 | 1522 | 445 | 4.10 / 690.15 | 6 | 66 |
6 | 13 | 121.08 | 20 | 14.91 | 488 | 146 | 4.24 / 690.29 | 6 | 52 |
7 | 13 | 29.00 | 20 | 14.94 | 346 | 103 | 4.35 / 690.39 | 6 | 47 |
8 | 8 | 0.16 | 244 | 14.89 | 291 | 1057 | 5.41 / 691.45 | 6 | 138 |
Average= | 9.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 36 | 14.90 | 432 | 232 | 0.23 / 680.90 | 6 | 13 |
2 | 7 | 2010.08 | 40 | 14.45 | 3088 | 1785 | 2.02 / 682.68 | 13 | 49 |
3 | 13 | 1933.92 | 20 | 14.43 | 3014 | 870 | 2.89 / 683.55 | 6 | 53 |
4 | 13 | 1405.00 | 20 | 14.48 | 2295 | 665 | 3.55 / 684.22 | 6 | 61 |
5 | 13 | 884.92 | 20 | 14.61 | 1560 | 456 | 4.01 / 684.68 | 6 | 65 |
6 | 13 | 218.80 | 20 | 14.86 | 651 | 193 | 4.20 / 684.87 | 6 | 58 |
7 | 13 | 24.24 | 20 | 14.93 | 345 | 103 | 4.30 / 684.97 | 6 | 50 |
8 | 8 | 0.12 | 244 | 14.88 | 296 | 1075 | 5.38 / 686.05 | 6 | 142 |
Average= | 9.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 36 | 14.90 | 432 | 232 | 0.23 / 675.45 | 6 | 12 |
2 | 7 | 2014.64 | 40 | 14.46 | 3098 | 1792 | 2.02 / 677.25 | 12 | 48 |
3 | 13 | 1928.28 | 20 | 14.44 | 2988 | 863 | 2.89 / 678.11 | 6 | 51 |
4 | 13 | 1509.36 | 20 | 14.46 | 2434 | 704 | 3.59 / 678.81 | 6 | 60 |
5 | 13 | 973.40 | 20 | 14.58 | 1687 | 492 | 4.08 / 679.30 | 6 | 64 |
6 | 13 | 217.16 | 20 | 14.86 | 644 | 191 | 4.27 / 679.50 | 6 | 57 |
7 | 8 | 0.08 | 267 | 14.89 | 295 | 1173 | 5.45 / 680.67 | 6 | -99 |
Average= | 10.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 36 | 14.90 | 430 | 231 | 0.23 / 669.91 | 6 | 11 |
2 | 7 | 2014.04 | 40 | 14.45 | 3105 | 1795 | 2.03 / 671.70 | 11 | 49 |
3 | 13 | 1952.80 | 20 | 14.42 | 3037 | 876 | 2.90 / 672.58 | 6 | 53 |
4 | 13 | 1542.80 | 20 | 14.45 | 2475 | 715 | 3.62 / 673.29 | 6 | 59 |
5 | 13 | 1110.72 | 20 | 14.53 | 1879 | 546 | 4.16 / 673.84 | 6 | 66 |
6 | 13 | 227.56 | 20 | 14.86 | 657 | 195 | 4.36 / 674.03 | 6 | 60 |
7 | 13 | 27.64 | 20 | 14.93 | 350 | 105 | 4.46 / 674.14 | 6 | 48 |
8 | 8 | 0.08 | 246 | 14.89 | 296 | 1084 | 5.55 / 675.22 | 6 | -99 |
Average= | 10.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 36 | 14.89 | 445 | 239 | 0.24 / 664.45 | 6 | 13 |
2 | 7 | 2006.00 | 40 | 14.46 | 3076 | 1779 | 2.02 / 666.22 | 37 | 48 |
3 | 13 | 1924.00 | 20 | 14.44 | 2969 | 857 | 2.88 / 667.08 | 6 | 52 |
4 | 13 | 1397.72 | 20 | 14.50 | 2273 | 659 | 3.53 / 667.74 | 6 | 60 |
5 | 13 | 962.88 | 20 | 14.58 | 1675 | 488 | 4.02 / 668.23 | 6 | 64 |
6 | 13 | 327.36 | 20 | 14.82 | 805 | 239 | 4.26 / 668.47 | 6 | 62 |
7 | 13 | 19.56 | 20 | 14.93 | 337 | 101 | 4.36 / 668.57 | 6 | 49 |
8 | 8 | 0.00 | 246 | 14.89 | 302 | 1106 | 5.47 / 669.68 | 6 | -99 |
Average= | 10.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 36 | 14.90 | 449 | 241 | 0.24 / 658.70 | 6 | 12 |
2 | 7 | 2007.16 | 40 | 14.46 | 3103 | 1795 | 2.04 / 660.50 | 12 | 48 |
3 | 13 | 1921.48 | 20 | 14.45 | 2982 | 862 | 2.90 / 661.36 | 6 | 52 |
4 | 13 | 1718.12 | 20 | 14.41 | 2722 | 784 | 3.68 / 662.14 | 6 | 58 |
5 | 13 | 1237.44 | 20 | 14.50 | 2069 | 600 | 4.28 / 662.74 | 6 | 64 |
6 | 13 | 403.28 | 20 | 14.78 | 918 | 271 | 4.55 / 663.01 | 6 | 66 |
7 | 13 | 16.52 | 20 | 14.94 | 328 | 98 | 4.65 / 663.11 | 6 | 48 |
8 | 8 | 0.00 | 246 | 14.88 | 299 | 1094 | 5.75 / 664.21 | 6 | 161 |
Average= | 10.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 36 | 14.90 | 448 | 240 | 0.24 / 653.14 | 6 | 12 |
2 | 7 | 2013.68 | 40 | 14.45 | 3113 | 1799 | 2.04 / 654.94 | 12 | 49 |
3 | 13 | 1917.32 | 20 | 14.44 | 2971 | 858 | 2.90 / 655.80 | 6 | 52 |
4 | 13 | 1598.08 | 20 | 14.44 | 2545 | 735 | 3.63 / 656.54 | 6 | 59 |
5 | 13 | 1050.16 | 20 | 14.56 | 1794 | 522 | 4.16 / 657.06 | 6 | 64 |
6 | 13 | 279.08 | 20 | 14.84 | 731 | 217 | 4.37 / 657.27 | 6 | 61 |
7 | 13 | 36.40 | 20 | 14.93 | 368 | 110 | 4.48 / 657.38 | 6 | 48 |
8 | 8 | 0.12 | 246 | 14.89 | 294 | 1077 | 5.56 / 658.46 | 6 | -99 |
Average= | 10.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 36 | 14.90 | 429 | 230 | 0.23 / 647.66 | 6 | 14 |
2 | 7 | 2005.60 | 40 | 14.46 | 3094 | 1790 | 2.02 / 649.45 | 14 | 48 |
3 | 13 | 1919.08 | 20 | 14.45 | 2980 | 861 | 2.88 / 650.31 | 6 | 52 |
4 | 13 | 1621.76 | 20 | 14.44 | 2571 | 743 | 3.62 / 651.05 | 6 | 58 |
5 | 13 | 953.84 | 20 | 14.59 | 1671 | 488 | 4.11 / 651.54 | 6 | 67 |
6 | 13 | 179.12 | 20 | 14.89 | 589 | 175 | 4.29 / 651.72 | 6 | 56 |
7 | 13 | 39.12 | 20 | 14.94 | 363 | 108 | 4.39 / 651.83 | 6 | 50 |
8 | 8 | 0.12 | 246 | 14.89 | 294 | 1077 | 5.47 / 652.90 | 6 | -99 |
Average= | 10.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 36 | 14.90 | 448 | 240 | 0.24 / 642.04 | 6 | 13 |
2 | 7 | 2005.72 | 40 | 14.46 | 3093 | 1789 | 2.03 / 643.82 | 13 | 48 |
3 | 13 | 1914.00 | 20 | 14.45 | 2969 | 858 | 2.89 / 644.68 | 6 | 53 |
4 | 13 | 1714.40 | 20 | 14.42 | 2700 | 779 | 3.67 / 645.46 | 6 | 56 |
5 | 13 | 942.28 | 20 | 14.60 | 1661 | 485 | 4.15 / 645.95 | 6 | 67 |
6 | 13 | 491.96 | 20 | 14.75 | 1031 | 304 | 4.46 / 646.25 | 6 | 66 |
7 | 8 | 0.04 | 267 | 14.89 | 297 | 1181 | 5.64 / 647.43 | 6 | -99 |
Average= | 10.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 36 | 14.89 | 437 | 234 | 0.23 / 636.51 | 6 | 12 |
2 | 7 | 2011.88 | 41 | 14.46 | 3105 | 1841 | 2.08 / 638.35 | 12 | 49 |
3 | 13 | 1924.12 | 20 | 14.44 | 3001 | 867 | 2.94 / 639.22 | 6 | 52 |
4 | 13 | 1405.20 | 20 | 14.49 | 2290 | 664 | 3.61 / 639.88 | 6 | 60 |
5 | 13 | 978.24 | 20 | 14.58 | 1703 | 497 | 4.10 / 640.38 | 6 | 64 |
6 | 13 | 314.28 | 20 | 14.82 | 787 | 233 | 4.34 / 640.61 | 6 | 63 |
7 | 13 | 18.88 | 20 | 14.93 | 331 | 99 | 4.43 / 640.71 | 6 | 49 |
8 | 8 | 0.08 | 244 | 14.89 | 298 | 1083 | 5.52 / 641.79 | 6 | 152 |
Average= | 10.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 36 | 14.90 | 446 | 239 | 0.24 / 630.99 | 6 | 13 |
2 | 7 | 2002.92 | 40 | 14.47 | 3074 | 1779 | 2.02 / 632.77 | 13 | 48 |
3 | 13 | 1907.36 | 20 | 14.45 | 2967 | 857 | 2.88 / 633.62 | 6 | 52 |
4 | 13 | 1487.92 | 20 | 14.48 | 2395 | 694 | 3.57 / 634.32 | 6 | 59 |
5 | 13 | 950.88 | 20 | 14.60 | 1659 | 484 | 4.05 / 634.80 | 6 | 65 |
6 | 13 | 505.00 | 20 | 14.74 | 1042 | 307 | 4.36 / 635.11 | 6 | 65 |
7 | 8 | 0.12 | 267 | 14.89 | 294 | 1169 | 5.53 / 636.28 | 6 | -99 |
Average= | 10.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 36 | 14.90 | 441 | 237 | 0.24 / 625.55 | 6 | 14 |
2 | 7 | 2005.32 | 40 | 14.47 | 3072 | 1778 | 2.01 / 627.33 | 14 | 48 |
3 | 13 | 1922.20 | 20 | 14.45 | 2981 | 862 | 2.88 / 628.19 | 6 | 51 |
4 | 13 | 1499.08 | 20 | 14.48 | 2413 | 699 | 3.57 / 628.89 | 6 | 59 |
5 | 13 | 961.56 | 20 | 14.60 | 1682 | 491 | 4.07 / 629.38 | 6 | 65 |
6 | 13 | 213.12 | 20 | 14.88 | 635 | 189 | 4.26 / 629.57 | 6 | 57 |
7 | 8 | 0.08 | 265 | 14.90 | 298 | 1177 | 5.43 / 630.75 | 6 | -99 |
Average= | 10.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 36 | 14.90 | 430 | 231 | 0.23 / 619.98 | 6 | 14 |
2 | 7 | 2013.80 | 41 | 14.47 | 3088 | 1832 | 2.06 / 621.82 | 14 | 49 |
3 | 13 | 1920.44 | 20 | 14.45 | 2993 | 865 | 2.93 / 622.68 | 6 | 52 |
4 | 13 | 1610.28 | 20 | 14.44 | 2569 | 742 | 3.67 / 623.42 | 6 | 58 |
5 | 13 | 855.76 | 20 | 14.64 | 1533 | 449 | 4.12 / 623.87 | 6 | 68 |
6 | 13 | 416.08 | 20 | 14.79 | 934 | 276 | 4.39 / 624.15 | 6 | 67 |
7 | 8 | 0.20 | 265 | 14.89 | 296 | 1168 | 5.56 / 625.32 | 6 | -99 |
Average= | 10.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 36 | 14.90 | 444 | 238 | 0.24 / 614.14 | 6 | 14 |
2 | 7 | 2006.88 | 40 | 14.47 | 3088 | 1787 | 2.03 / 615.93 | 14 | 48 |
3 | 13 | 1930.64 | 20 | 14.45 | 2994 | 865 | 2.89 / 616.79 | 6 | 52 |
4 | 13 | 1730.80 | 20 | 14.42 | 2717 | 784 | 3.67 / 617.58 | 6 | 57 |
5 | 13 | 1144.88 | 20 | 14.53 | 1919 | 558 | 4.23 / 618.13 | 6 | 64 |
6 | 13 | 672.64 | 20 | 14.68 | 1266 | 372 | 4.60 / 618.50 | 6 | 66 |
7 | 13 | 39.64 | 20 | 14.93 | 370 | 110 | 4.71 / 618.62 | 6 | 52 |
8 | 8 | 0.16 | 250 | 14.88 | 306 | 1138 | 5.85 / 619.75 | 6 | -99 |
Average= | 10.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 36 | 14.90 | 445 | 239 | 0.24 / 608.73 | 6 | 12 |
2 | 7 | 2002.96 | 40 | 14.47 | 3081 | 1783 | 2.02 / 610.51 | 12 | 48 |
3 | 13 | 1912.96 | 20 | 14.46 | 2973 | 860 | 2.88 / 611.37 | 6 | 52 |
4 | 13 | 1381.08 | 20 | 14.51 | 2242 | 651 | 3.53 / 612.02 | 6 | 60 |
5 | 13 | 848.76 | 20 | 14.64 | 1500 | 439 | 3.97 / 612.46 | 6 | 65 |
6 | 13 | 305.32 | 20 | 14.84 | 765 | 227 | 4.20 / 612.69 | 6 | 62 |
7 | 13 | 37.20 | 20 | 14.93 | 366 | 109 | 4.31 / 612.80 | 6 | 51 |
8 | 8 | 0.08 | 246 | 14.89 | 301 | 1103 | 5.41 / 613.90 | 6 | 164 |
Average= | 10.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 36 | 14.90 | 444 | 238 | 0.24 / 603.22 | 6 | 11 |
2 | 7 | 2006.96 | 40 | 14.47 | 3086 | 1786 | 2.02 / 605.01 | 11 | 49 |
3 | 13 | 1922.80 | 20 | 14.46 | 2973 | 860 | 2.88 / 605.87 | 6 | 52 |
4 | 13 | 1491.96 | 20 | 14.48 | 2398 | 694 | 3.58 / 606.56 | 6 | 60 |
5 | 13 | 1056.92 | 20 | 14.56 | 1807 | 526 | 4.10 / 607.09 | 6 | 65 |
6 | 13 | 276.56 | 20 | 14.84 | 728 | 216 | 4.32 / 607.31 | 6 | 61 |
7 | 8 | 0.12 | 265 | 14.90 | 300 | 1185 | 5.51 / 608.49 | 6 | -99 |
Average= | 11.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 36 | 14.90 | 444 | 238 | 0.24 / 597.63 | 6 | 11 |
2 | 7 | 2007.44 | 40 | 14.47 | 3084 | 1785 | 2.02 / 599.41 | 11 | 50 |
3 | 13 | 1921.32 | 20 | 14.46 | 2978 | 861 | 2.88 / 600.27 | 6 | 53 |
4 | 13 | 1618.88 | 20 | 14.45 | 2568 | 742 | 3.63 / 601.02 | 6 | 58 |
5 | 13 | 962.44 | 20 | 14.60 | 1673 | 489 | 4.12 / 601.50 | 6 | 66 |
6 | 13 | 409.84 | 20 | 14.79 | 928 | 275 | 4.39 / 601.78 | 6 | 66 |
7 | 13 | 36.24 | 20 | 14.94 | 358 | 107 | 4.50 / 601.89 | 6 | 51 |
8 | 8 | 0.12 | 246 | 14.89 | 300 | 1099 | 5.60 / 602.99 | 6 | 166 |
Average= | 11.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 36 | 14.90 | 431 | 231 | 0.23 / 592.13 | 6 | 12 |
2 | 7 | 2005.16 | 40 | 14.48 | 3084 | 1786 | 2.02 / 593.92 | 12 | 48 |
3 | 13 | 1923.32 | 20 | 14.46 | 2985 | 863 | 2.88 / 594.78 | 6 | 51 |
4 | 13 | 1332.04 | 20 | 14.53 | 2187 | 636 | 3.52 / 595.42 | 6 | 60 |
5 | 13 | 1019.88 | 20 | 14.59 | 1742 | 508 | 4.02 / 595.93 | 6 | 63 |
6 | 13 | 355.96 | 20 | 14.81 | 847 | 251 | 4.28 / 596.18 | 6 | 64 |
7 | 13 | 28.12 | 20 | 14.94 | 348 | 104 | 4.38 / 596.28 | 6 | 49 |
8 | 8 | 0.12 | 248 | 14.89 | 300 | 1108 | 5.49 / 597.39 | 6 | -99 |
Average= | 11.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 36 | 14.90 | 436 | 234 | 0.23 / 586.71 | 6 | 11 |
2 | 7 | 2007.20 | 40 | 14.48 | 3088 | 1789 | 2.02 / 588.50 | 11 | 49 |
3 | 13 | 1923.16 | 20 | 14.45 | 2983 | 862 | 2.88 / 589.36 | 6 | 53 |
4 | 13 | 1491.80 | 20 | 14.49 | 2410 | 698 | 3.58 / 590.06 | 6 | 59 |
5 | 13 | 825.76 | 20 | 14.65 | 1495 | 438 | 4.02 / 590.50 | 6 | 66 |
6 | 13 | 270.12 | 20 | 14.85 | 725 | 215 | 4.24 / 590.71 | 6 | 62 |
7 | 13 | 34.60 | 20 | 14.93 | 366 | 109 | 4.35 / 590.82 | 6 | 51 |
8 | 8 | 0.08 | 246 | 14.89 | 295 | 1081 | 5.43 / 591.90 | 6 | -99 |
Average= | 11.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 36 | 14.91 | 444 | 238 | 0.24 / 581.29 | 6 | 13 |
2 | 7 | 2006.68 | 40 | 14.48 | 3068 | 1777 | 2.02 / 583.06 | 13 | 48 |
3 | 13 | 1929.00 | 20 | 14.46 | 2988 | 864 | 2.88 / 583.93 | 6 | 54 |
4 | 13 | 1497.80 | 20 | 14.48 | 2416 | 700 | 3.58 / 584.63 | 6 | 61 |
5 | 13 | 866.76 | 20 | 14.63 | 1558 | 456 | 4.03 / 585.08 | 6 | 65 |
6 | 13 | 219.44 | 20 | 14.87 | 652 | 194 | 4.23 / 585.28 | 6 | 58 |
7 | 13 | 52.68 | 20 | 14.93 | 390 | 116 | 4.35 / 585.39 | 6 | 51 |
8 | 8 | -0.08 | 244 | 14.89 | 298 | 1083 | 5.43 / 586.48 | 6 | 138 |
Average= | 11.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 36 | 14.91 | 435 | 233 | 0.23 / 575.72 | 6 | 12 |
2 | 7 | 2008.24 | 40 | 14.48 | 3086 | 1787 | 2.02 / 577.51 | 12 | 48 |
3 | 13 | 1936.76 | 20 | 14.46 | 3000 | 868 | 2.89 / 578.38 | 6 | 52 |
4 | 13 | 1643.24 | 20 | 14.45 | 2600 | 751 | 3.64 / 579.13 | 6 | 58 |
5 | 13 | 994.12 | 20 | 14.59 | 1724 | 503 | 4.14 / 579.63 | 6 | 66 |
6 | 13 | 249.64 | 20 | 14.87 | 691 | 206 | 4.35 / 579.84 | 6 | 60 |
7 | 13 | 67.52 | 20 | 14.93 | 412 | 123 | 4.47 / 579.96 | 6 | 49 |
8 | 8 | 0.20 | 248 | 14.90 | 294 | 1086 | 5.56 / 581.05 | 6 | -99 |
Average= | 11.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 36 | 14.91 | 432 | 232 | 0.23 / 570.22 | 6 | 10 |
2 | 7 | 2013.48 | 40 | 14.47 | 3105 | 1797 | 2.03 / 572.02 | 10 | 48 |
3 | 13 | 1928.32 | 20 | 14.45 | 2998 | 866 | 2.90 / 572.89 | 6 | 52 |
4 | 13 | 1517.28 | 20 | 14.47 | 2444 | 707 | 3.60 / 573.60 | 6 | 60 |
5 | 13 | 968.48 | 20 | 14.60 | 1686 | 492 | 4.10 / 574.09 | 6 | 68 |
6 | 13 | 210.00 | 20 | 14.88 | 636 | 189 | 4.28 / 574.28 | 6 | 59 |
7 | 13 | 48.04 | 20 | 14.94 | 382 | 114 | 4.40 / 574.39 | 6 | 47 |
8 | 8 | -0.04 | 246 | 14.89 | 300 | 1099 | 5.50 / 575.49 | 6 | -99 |
Average= | 11.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 36 | 14.90 | 432 | 232 | 0.23 / 564.77 | 6 | 11 |
2 | 7 | 2013.00 | 40 | 14.48 | 3096 | 1793 | 2.02 / 566.56 | 11 | 50 |
3 | 13 | 1925.80 | 20 | 14.46 | 2988 | 864 | 2.89 / 567.42 | 6 | 51 |
4 | 13 | 1431.60 | 20 | 14.50 | 2329 | 675 | 3.56 / 568.10 | 6 | 61 |
5 | 13 | 911.12 | 20 | 14.62 | 1612 | 471 | 4.04 / 568.57 | 6 | 65 |
6 | 13 | 263.64 | 20 | 14.86 | 713 | 212 | 4.25 / 568.78 | 6 | 58 |
7 | 13 | 37.12 | 20 | 14.94 | 372 | 111 | 4.36 / 568.89 | 6 | 47 |
8 | 8 | 0.08 | 246 | 14.90 | 300 | 1100 | 5.46 / 569.99 | 6 | -99 |
Average= | 11.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.88 | 36 | 14.92 | 445 | 239 | 0.24 / 559.21 | 6 | 10 |
2 | 7 | 2005.00 | 40 | 14.49 | 3057 | 1772 | 2.01 / 560.98 | 10 | 47 |
3 | 13 | 1919.16 | 20 | 14.47 | 2978 | 862 | 2.87 / 561.84 | 6 | 53 |
4 | 13 | 1618.56 | 20 | 14.46 | 2574 | 744 | 3.62 / 562.59 | 6 | 58 |
5 | 13 | 971.04 | 20 | 14.60 | 1702 | 497 | 4.11 / 563.08 | 6 | 67 |
6 | 13 | 319.44 | 20 | 14.84 | 797 | 237 | 4.35 / 563.32 | 6 | 60 |
7 | 13 | 44.16 | 20 | 14.94 | 385 | 115 | 4.47 / 563.43 | 6 | 51 |
8 | 8 | 0.08 | 246 | 14.90 | 300 | 1100 | 5.57 / 564.53 | 6 | -99 |
Average= | 12.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 36 | 14.92 | 421 | 226 | 0.23 / 553.67 | 6 | 10 |
2 | 7 | 2010.28 | 40 | 14.49 | 3079 | 1785 | 2.01 / 555.45 | 10 | 47 |
3 | 13 | 1930.24 | 20 | 14.47 | 2981 | 863 | 2.87 / 556.32 | 6 | 53 |
4 | 13 | 1490.16 | 20 | 14.50 | 2391 | 693 | 3.57 / 557.01 | 6 | 60 |
5 | 13 | 1058.48 | 20 | 14.57 | 1809 | 527 | 4.09 / 557.54 | 6 | 65 |
6 | 13 | 293.16 | 20 | 14.85 | 750 | 223 | 4.32 / 557.76 | 6 | 61 |
7 | 13 | 42.96 | 20 | 14.94 | 375 | 112 | 4.43 / 557.87 | 6 | 50 |
8 | 8 | 0.04 | 248 | 14.90 | 297 | 1097 | 5.53 / 558.97 | 6 | -99 |
Average= | 12.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 36 | 14.91 | 432 | 232 | 0.23 / 548.12 | 6 | 12 |
2 | 7 | 2005.64 | 40 | 14.47 | 3075 | 1780 | 2.01 / 549.90 | 12 | 49 |
3 | 13 | 1920.12 | 20 | 14.46 | 2977 | 861 | 2.87 / 550.76 | 6 | 52 |
4 | 13 | 1723.48 | 20 | 14.43 | 2711 | 782 | 3.66 / 551.54 | 6 | 56 |
5 | 13 | 837.40 | 20 | 14.65 | 1515 | 444 | 4.10 / 551.99 | 6 | 68 |
6 | 13 | 402.28 | 20 | 14.81 | 918 | 272 | 4.37 / 552.26 | 6 | 67 |
7 | 13 | 40.04 | 20 | 14.94 | 375 | 112 | 4.48 / 552.37 | 6 | 50 |
8 | 8 | 0.04 | 246 | 14.90 | 293 | 1074 | 5.56 / 553.44 | 6 | 167 |
Average= | 12.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 36 | 14.91 | 438 | 235 | 0.24 / 542.54 | 6 | 11 |
2 | 7 | 2004.96 | 40 | 14.49 | 3077 | 1783 | 2.02 / 544.33 | 11 | 48 |
3 | 13 | 1925.12 | 20 | 14.47 | 2967 | 859 | 2.88 / 545.19 | 6 | 52 |
4 | 13 | 1619.36 | 20 | 14.46 | 2563 | 741 | 3.62 / 545.93 | 6 | 58 |
5 | 13 | 969.52 | 20 | 14.61 | 1690 | 494 | 4.11 / 546.42 | 6 | 67 |
6 | 13 | 411.60 | 20 | 14.80 | 925 | 274 | 4.39 / 546.69 | 6 | 66 |
7 | 13 | 37.20 | 20 | 14.94 | 362 | 108 | 4.49 / 546.80 | 6 | 50 |
8 | 8 | 0.12 | 248 | 14.91 | 293 | 1083 | 5.58 / 547.89 | 6 | -99 |
Average= | 12.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 36 | 14.91 | 445 | 239 | 0.24 / 537.08 | 6 | 13 |
2 | 7 | 2012.32 | 40 | 14.48 | 3089 | 1789 | 2.03 / 538.87 | 13 | 48 |
3 | 13 | 1915.56 | 20 | 14.47 | 2959 | 856 | 2.88 / 539.73 | 6 | 53 |
4 | 13 | 1497.36 | 20 | 14.50 | 2406 | 698 | 3.58 / 540.43 | 6 | 60 |
5 | 13 | 966.76 | 20 | 14.61 | 1684 | 492 | 4.07 / 540.92 | 6 | 67 |
6 | 13 | 189.96 | 20 | 14.90 | 608 | 181 | 4.26 / 541.10 | 6 | 60 |
7 | 13 | 42.64 | 20 | 14.95 | 376 | 112 | 4.37 / 541.21 | 6 | 51 |
8 | 8 | 0.08 | 246 | 14.90 | 299 | 1096 | 5.46 / 542.31 | 6 | -99 |
Average= | 12.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 36 | 14.91 | 423 | 227 | 0.23 / 531.56 | 6 | 14 |
2 | 7 | 2018.08 | 41 | 14.47 | 3100 | 1839 | 2.07 / 533.40 | 14 | 48 |
3 | 13 | 1935.24 | 20 | 14.46 | 2990 | 865 | 2.93 / 534.26 | 6 | 52 |
4 | 13 | 1519.44 | 20 | 14.48 | 2439 | 706 | 3.64 / 534.97 | 6 | 60 |
5 | 13 | 969.80 | 20 | 14.61 | 1671 | 488 | 4.13 / 535.46 | 6 | 65 |
6 | 13 | 214.20 | 20 | 14.89 | 639 | 190 | 4.32 / 535.65 | 6 | 58 |
7 | 13 | 22.96 | 20 | 14.95 | 346 | 103 | 4.42 / 535.75 | 6 | 50 |
8 | 8 | 0.04 | 246 | 14.91 | 298 | 1093 | 5.51 / 536.84 | 6 | -99 |
Average= | 12.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 36 | 14.92 | 430 | 231 | 0.23 / 525.91 | 6 | 11 |
2 | 7 | 2015.20 | 40 | 14.48 | 3087 | 1788 | 2.02 / 527.70 | 11 | 49 |
3 | 13 | 1928.48 | 20 | 14.47 | 2985 | 864 | 2.88 / 528.56 | 6 | 52 |
4 | 13 | 1618.24 | 20 | 14.47 | 2571 | 744 | 3.63 / 529.30 | 6 | 59 |
5 | 13 | 959.96 | 20 | 14.62 | 1667 | 487 | 4.11 / 529.79 | 6 | 65 |
6 | 13 | 608.80 | 20 | 14.72 | 1170 | 344 | 4.46 / 530.14 | 6 | 66 |
7 | 13 | 53.00 | 20 | 14.93 | 384 | 115 | 4.57 / 530.25 | 6 | 51 |
8 | 8 | 0.00 | 248 | 14.90 | 293 | 1083 | 5.66 / 531.33 | 6 | 222 |
Average= | 12.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 36 | 14.92 | 440 | 236 | 0.24 / 520.46 | 6 | 10 |
2 | 7 | 2012.00 | 40 | 14.48 | 3105 | 1798 | 2.03 / 522.26 | 10 | 49 |
3 | 13 | 1923.12 | 20 | 14.47 | 2976 | 861 | 2.90 / 523.12 | 6 | 52 |
4 | 13 | 1629.84 | 20 | 14.46 | 2585 | 748 | 3.64 / 523.87 | 6 | 59 |
5 | 13 | 845.56 | 20 | 14.66 | 1527 | 448 | 4.09 / 524.31 | 6 | 68 |
6 | 13 | 213.56 | 20 | 14.89 | 638 | 190 | 4.28 / 524.50 | 6 | 59 |
7 | 8 | 0.08 | 263 | 14.91 | 299 | 1172 | 5.45 / 525.68 | 6 | 144 |
Average= | 13.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 36 | 14.91 | 457 | 245 | 0.25 / 514.96 | 6 | 13 |
2 | 7 | 2006.20 | 40 | 14.49 | 3084 | 1787 | 2.03 / 516.75 | 13 | 49 |
3 | 13 | 1925.60 | 20 | 14.47 | 2973 | 860 | 2.89 / 517.61 | 6 | 51 |
4 | 13 | 1514.00 | 20 | 14.49 | 2440 | 707 | 3.60 / 518.32 | 6 | 59 |
5 | 13 | 889.28 | 20 | 14.64 | 1578 | 462 | 4.06 / 518.78 | 6 | 64 |
6 | 13 | 337.44 | 20 | 14.84 | 824 | 245 | 4.31 / 519.02 | 6 | 65 |
7 | 13 | 23.40 | 20 | 14.95 | 349 | 104 | 4.41 / 519.13 | 6 | 50 |
8 | 8 | 0.12 | 246 | 14.91 | 299 | 1097 | 5.51 / 520.22 | 6 | -99 |
Average= | 13.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 36 | 14.92 | 432 | 232 | 0.23 / 509.24 | 6 | 13 |
2 | 7 | 2007.40 | 40 | 14.50 | 3078 | 1785 | 2.02 / 511.02 | 13 | 48 |
3 | 13 | 1923.08 | 20 | 14.47 | 2982 | 863 | 2.88 / 511.89 | 6 | 52 |
4 | 13 | 1725.24 | 20 | 14.45 | 2686 | 776 | 3.66 / 512.66 | 6 | 57 |
5 | 13 | 1048.28 | 20 | 14.59 | 1797 | 524 | 4.18 / 513.19 | 6 | 63 |
6 | 13 | 484.72 | 20 | 14.78 | 1019 | 301 | 4.48 / 513.49 | 6 | 66 |
7 | 13 | 27.40 | 20 | 14.95 | 356 | 106 | 4.59 / 513.60 | 6 | 49 |
8 | 8 | 0.12 | 248 | 14.90 | 303 | 1120 | 5.71 / 514.71 | 6 | -99 |
Average= | 13.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 36 | 14.92 | 436 | 234 | 0.23 / 503.76 | 6 | 12 |
2 | 7 | 2005.32 | 40 | 14.50 | 3077 | 1785 | 2.02 / 505.55 | 12 | 47 |
3 | 13 | 1930.76 | 20 | 14.48 | 2992 | 866 | 2.89 / 506.41 | 6 | 52 |
4 | 13 | 1410.00 | 20 | 14.52 | 2298 | 667 | 3.55 / 507.08 | 6 | 60 |
5 | 13 | 1097.24 | 20 | 14.57 | 1862 | 543 | 4.10 / 507.62 | 6 | 65 |
6 | 13 | 206.64 | 20 | 14.90 | 631 | 188 | 4.28 / 507.81 | 6 | 59 |
7 | 13 | 23.32 | 20 | 14.96 | 344 | 103 | 4.39 / 507.91 | 6 | 50 |
8 | 8 | -0.04 | 246 | 14.91 | 298 | 1093 | 5.48 / 509.01 | 6 | -99 |
Average= | 13.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 36 | 14.92 | 432 | 232 | 0.23 / 498.39 | 6 | 16 |
2 | 7 | 2003.56 | 40 | 14.50 | 3078 | 1785 | 2.02 / 500.17 | 16 | 47 |
3 | 13 | 1918.28 | 20 | 14.49 | 2970 | 861 | 2.88 / 501.03 | 6 | 51 |
4 | 13 | 1320.40 | 20 | 14.56 | 2160 | 629 | 3.51 / 501.66 | 6 | 60 |
5 | 13 | 911.48 | 20 | 14.64 | 1589 | 465 | 3.97 / 502.13 | 6 | 63 |
6 | 13 | 266.08 | 20 | 14.87 | 720 | 214 | 4.19 / 502.34 | 6 | 61 |
7 | 13 | 16.44 | 20 | 14.96 | 330 | 99 | 4.29 / 502.44 | 6 | 49 |
8 | 8 | 0.04 | 246 | 14.91 | 297 | 1089 | 5.37 / 503.53 | 6 | -99 |
Average= | 13.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 36 | 14.93 | 435 | 234 | 0.23 / 492.79 | 6 | 15 |
2 | 7 | 2006.68 | 40 | 14.49 | 3085 | 1788 | 2.02 / 494.57 | 15 | 50 |
3 | 13 | 1920.16 | 20 | 14.48 | 2983 | 864 | 2.89 / 495.44 | 6 | 52 |
4 | 13 | 1605.32 | 20 | 14.48 | 2547 | 738 | 3.62 / 496.18 | 6 | 57 |
5 | 13 | 1050.08 | 20 | 14.59 | 1807 | 527 | 4.15 / 496.70 | 6 | 65 |
6 | 13 | 362.08 | 20 | 14.83 | 857 | 254 | 4.40 / 496.96 | 6 | 66 |
7 | 13 | 14.56 | 20 | 14.96 | 333 | 100 | 4.50 / 497.06 | 6 | 48 |
8 | 8 | 0.08 | 246 | 14.91 | 299 | 1097 | 5.60 / 498.15 | 6 | 181 |
Average= | 14.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 36 | 14.93 | 441 | 237 | 0.24 / 487.27 | 6 | 13 |
2 | 7 | 2013.36 | 40 | 14.50 | 3110 | 1804 | 2.04 / 489.07 | 13 | 48 |
3 | 13 | 1929.20 | 20 | 14.48 | 2998 | 868 | 2.91 / 489.94 | 6 | 53 |
4 | 13 | 1518.56 | 20 | 14.50 | 2458 | 713 | 3.62 / 490.65 | 6 | 60 |
5 | 13 | 1063.00 | 20 | 14.59 | 1815 | 530 | 4.15 / 491.18 | 6 | 65 |
6 | 13 | 193.96 | 20 | 14.91 | 604 | 180 | 4.33 / 491.36 | 6 | 58 |
7 | 13 | 19.48 | 20 | 14.97 | 340 | 102 | 4.43 / 491.47 | 6 | 47 |
8 | 8 | 0.04 | 246 | 14.92 | 296 | 1086 | 5.52 / 492.55 | 6 | -99 |
Average= | 14.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 35 | 14.91 | 450 | 235 | 0.23 / 481.82 | 6 | 13 |
2 | 7 | 2023.04 | 40 | 14.49 | 3112 | 1804 | 2.04 / 483.63 | 41 | 49 |
3 | 13 | 1953.60 | 20 | 14.47 | 3032 | 877 | 2.92 / 484.51 | 6 | 52 |
4 | 13 | 1432.68 | 20 | 14.52 | 2323 | 675 | 3.59 / 485.18 | 6 | 60 |
5 | 13 | 885.04 | 20 | 14.65 | 1567 | 459 | 4.05 / 485.64 | 6 | 66 |
6 | 13 | 239.88 | 20 | 14.89 | 676 | 201 | 4.25 / 485.84 | 6 | 57 |
7 | 13 | 26.92 | 20 | 14.97 | 349 | 104 | 4.36 / 485.95 | 6 | 50 |
8 | 8 | -0.04 | 246 | 14.92 | 296 | 1086 | 5.44 / 487.03 | 6 | -99 |
Average= | 14.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 36 | 14.93 | 430 | 231 | 0.23 / 476.33 | 6 | 15 |
2 | 7 | 2006.08 | 40 | 14.50 | 3079 | 1786 | 2.02 / 478.11 | 15 | 47 |
3 | 13 | 1915.36 | 20 | 14.49 | 2969 | 860 | 2.88 / 478.97 | 6 | 53 |
4 | 13 | 1493.40 | 20 | 14.51 | 2400 | 696 | 3.57 / 479.67 | 6 | 59 |
5 | 13 | 950.12 | 20 | 14.63 | 1659 | 485 | 4.06 / 480.16 | 6 | 65 |
6 | 13 | 273.40 | 20 | 14.87 | 731 | 217 | 4.28 / 480.37 | 6 | 59 |
7 | 13 | 14.64 | 20 | 14.97 | 339 | 101 | 4.38 / 480.48 | 6 | 48 |
8 | 8 | 0.08 | 246 | 14.91 | 304 | 1115 | 5.49 / 481.59 | 6 | -99 |
Average= | 15.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 36 | 14.93 | 438 | 235 | 0.24 / 470.93 | 6 | 16 |
2 | 7 | 2005.64 | 40 | 14.51 | 3075 | 1785 | 2.02 / 472.71 | 16 | 48 |
3 | 13 | 1924.32 | 20 | 14.49 | 2981 | 864 | 2.88 / 473.58 | 6 | 53 |
4 | 13 | 1528.12 | 20 | 14.51 | 2455 | 712 | 3.60 / 474.29 | 6 | 59 |
5 | 13 | 890.72 | 20 | 14.66 | 1576 | 462 | 4.06 / 474.75 | 6 | 64 |
6 | 13 | 154.64 | 20 | 14.93 | 551 | 165 | 4.22 / 474.92 | 6 | 54 |
7 | 8 | 0.12 | 265 | 14.93 | 298 | 1179 | 5.40 / 476.10 | 6 | 145 |
Average= | 15.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 36 | 14.94 | 428 | 230 | 0.23 / 465.45 | 6 | 17 |
2 | 7 | 2007.52 | 40 | 14.51 | 3078 | 1786 | 2.02 / 467.23 | 17 | 48 |
3 | 13 | 1931.36 | 20 | 14.49 | 2988 | 866 | 2.88 / 468.10 | 6 | 52 |
4 | 13 | 1628.44 | 20 | 14.48 | 2585 | 749 | 3.63 / 468.85 | 6 | 58 |
5 | 13 | 869.48 | 20 | 14.67 | 1558 | 457 | 4.09 / 469.31 | 6 | 66 |
6 | 13 | 228.76 | 20 | 14.90 | 662 | 197 | 4.29 / 469.50 | 6 | 56 |
7 | 8 | 0.04 | 265 | 14.93 | 301 | 1191 | 5.48 / 470.69 | 6 | 144 |
Average= | 15.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 35 | 14.93 | 446 | 233 | 0.23 / 460.07 | 6 | 14 |
2 | 7 | 2007.76 | 40 | 14.51 | 3080 | 1788 | 2.02 / 461.86 | 14 | 47 |
3 | 13 | 1925.32 | 20 | 14.49 | 2981 | 864 | 2.88 / 462.72 | 6 | 52 |
4 | 13 | 1506.32 | 20 | 14.52 | 2424 | 704 | 3.59 / 463.42 | 6 | 59 |
5 | 13 | 872.48 | 20 | 14.67 | 1530 | 449 | 4.04 / 463.87 | 6 | 63 |
6 | 13 | 139.16 | 20 | 14.95 | 520 | 155 | 4.19 / 464.03 | 6 | 52 |
7 | 13 | 17.04 | 20 | 14.98 | 330 | 99 | 4.29 / 464.13 | 6 | 45 |
8 | 8 | 0.04 | 246 | 14.94 | 297 | 1092 | 5.38 / 465.22 | 6 | 149 |
Average= | 16.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 35 | 14.93 | 442 | 231 | 0.23 / 454.55 | 6 | 15 |
2 | 7 | 2009.84 | 40 | 14.50 | 3088 | 1791 | 2.02 / 456.34 | 15 | 49 |
3 | 13 | 1911.04 | 20 | 14.49 | 2960 | 858 | 2.88 / 457.20 | 6 | 53 |
4 | 13 | 1607.16 | 20 | 14.49 | 2558 | 741 | 3.62 / 457.94 | 6 | 59 |
5 | 13 | 936.32 | 20 | 14.64 | 1641 | 480 | 4.10 / 458.42 | 6 | 65 |
6 | 13 | 273.76 | 20 | 14.88 | 729 | 217 | 4.32 / 458.64 | 6 | 61 |
7 | 13 | 14.28 | 20 | 14.98 | 332 | 99 | 4.42 / 458.74 | 6 | 49 |
8 | 8 | 0.00 | 246 | 14.92 | 299 | 1097 | 5.52 / 459.83 | 6 | -99 |
Average= | 16.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 35 | 14.92 | 438 | 229 | 0.23 / 449.02 | 6 | 16 |
2 | 7 | 2011.56 | 40 | 14.50 | 3086 | 1790 | 2.02 / 450.81 | 16 | 50 |
3 | 13 | 1918.96 | 20 | 14.49 | 2966 | 860 | 2.88 / 451.67 | 6 | 52 |
4 | 13 | 1718.68 | 20 | 14.47 | 2706 | 783 | 3.66 / 452.45 | 6 | 58 |
5 | 13 | 844.24 | 20 | 14.68 | 1503 | 441 | 4.10 / 452.90 | 6 | 67 |
6 | 13 | 318.16 | 20 | 14.87 | 797 | 237 | 4.34 / 453.13 | 6 | 62 |
7 | 8 | 0.16 | 265 | 14.93 | 300 | 1187 | 5.53 / 454.32 | 6 | 135 |
Average= | 16.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 35 | 14.93 | 436 | 228 | 0.23 / 443.50 | 6 | 15 |
2 | 7 | 2004.36 | 40 | 14.51 | 3064 | 1778 | 2.01 / 445.28 | 25 | 49 |
3 | 13 | 1916.12 | 20 | 14.50 | 2961 | 859 | 2.86 / 446.14 | 6 | 52 |
4 | 13 | 1600.52 | 20 | 14.50 | 2546 | 738 | 3.60 / 446.88 | 6 | 58 |
5 | 13 | 951.36 | 20 | 14.64 | 1663 | 487 | 4.09 / 447.36 | 6 | 65 |
6 | 13 | 282.00 | 20 | 14.88 | 742 | 221 | 4.31 / 447.59 | 6 | 61 |
7 | 8 | 0.16 | 267 | 14.93 | 303 | 1208 | 5.52 / 448.79 | 6 | -99 |
Average= | 17.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 35 | 14.92 | 451 | 236 | 0.24 / 438.06 | 6 | 14 |
2 | 7 | 2012.96 | 40 | 14.51 | 3100 | 1799 | 2.03 / 439.85 | 14 | 49 |
3 | 13 | 1931.04 | 20 | 14.49 | 2998 | 869 | 2.90 / 440.72 | 6 | 54 |
4 | 13 | 1410.72 | 20 | 14.54 | 2291 | 666 | 3.57 / 441.39 | 6 | 61 |
5 | 13 | 988.20 | 20 | 14.63 | 1708 | 500 | 4.07 / 441.89 | 6 | 65 |
6 | 13 | 199.36 | 20 | 14.92 | 619 | 185 | 4.25 / 442.07 | 6 | 56 |
7 | 8 | 0.12 | 267 | 14.93 | 301 | 1200 | 5.45 / 443.27 | 6 | -99 |
Average= | 17.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 36 | 14.92 | 447 | 240 | 0.24 / 432.61 | 6 | 14 |
2 | 7 | 2012.52 | 40 | 14.51 | 3087 | 1792 | 2.03 / 434.40 | 14 | 48 |
3 | 13 | 1730.52 | 20 | 14.53 | 2727 | 792 | 2.82 / 435.20 | 6 | 56 |
4 | 13 | 1634.44 | 20 | 14.49 | 2584 | 749 | 3.57 / 435.95 | 6 | 59 |
5 | 13 | 944.84 | 20 | 14.64 | 1667 | 488 | 4.06 / 436.43 | 6 | 67 |
6 | 13 | 183.72 | 20 | 14.92 | 604 | 180 | 4.24 / 436.61 | 6 | 56 |
7 | 8 | 0.04 | 265 | 14.93 | 305 | 1207 | 5.45 / 437.82 | 6 | 214 |
Average= | 18.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 35 | 14.93 | 434 | 227 | 0.23 / 426.87 | 6 | 15 |
2 | 7 | 2005.40 | 41 | 14.51 | 3084 | 1835 | 2.06 / 428.70 | 15 | 50 |
3 | 13 | 1927.00 | 20 | 14.49 | 2980 | 864 | 2.93 / 429.56 | 6 | 52 |
4 | 13 | 1425.44 | 20 | 14.53 | 2322 | 675 | 3.60 / 430.24 | 6 | 61 |
5 | 13 | 1333.64 | 20 | 14.51 | 2187 | 635 | 4.23 / 430.87 | 6 | 63 |
6 | 13 | 366.80 | 20 | 14.84 | 876 | 260 | 4.49 / 431.13 | 6 | 65 |
7 | 8 | 0.12 | 267 | 14.92 | 311 | 1239 | 5.73 / 432.37 | 6 | -99 |
Average= | 18.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 35 | 14.93 | 449 | 235 | 0.23 / 421.36 | 6 | 14 |
2 | 7 | 2013.24 | 40 | 14.52 | 3078 | 1788 | 2.02 / 423.14 | 14 | 49 |
3 | 13 | 1923.76 | 20 | 14.50 | 2972 | 862 | 2.88 / 424.01 | 6 | 53 |
4 | 13 | 1416.08 | 20 | 14.55 | 2309 | 672 | 3.56 / 424.68 | 6 | 60 |
5 | 13 | 982.44 | 20 | 14.63 | 1714 | 502 | 4.06 / 425.18 | 6 | 66 |
6 | 13 | 315.76 | 20 | 14.87 | 790 | 235 | 4.29 / 425.41 | 6 | 61 |
7 | 8 | 0.04 | 267 | 14.93 | 307 | 1224 | 5.52 / 426.64 | 6 | -99 |
Average= | 19.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 35 | 14.94 | 443 | 232 | 0.23 / 415.74 | 6 | 14 |
2 | 7 | 2004.04 | 40 | 14.52 | 3070 | 1783 | 2.01 / 417.53 | 14 | 48 |
3 | 13 | 1916.20 | 20 | 14.50 | 2970 | 861 | 2.88 / 418.39 | 6 | 52 |
4 | 13 | 1719.80 | 20 | 14.47 | 2711 | 785 | 3.66 / 419.17 | 6 | 57 |
5 | 13 | 1024.16 | 20 | 14.62 | 1773 | 518 | 4.18 / 419.69 | 6 | 65 |
6 | 13 | 252.88 | 20 | 14.91 | 698 | 208 | 4.39 / 419.90 | 6 | 58 |
7 | 8 | 0.04 | 267 | 14.94 | 307 | 1225 | 5.61 / 421.12 | 6 | -99 |
Average= | 20.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 35 | 14.93 | 433 | 226 | 0.23 / 410.09 | 6 | 13 |
2 | 7 | 2013.80 | 41 | 14.51 | 3087 | 1836 | 2.06 / 411.92 | 28 | 48 |
3 | 13 | 1918.64 | 20 | 14.51 | 2940 | 853 | 2.92 / 412.78 | 6 | 52 |
4 | 13 | 1712.80 | 20 | 14.48 | 2676 | 775 | 3.69 / 413.55 | 6 | 56 |
5 | 13 | 957.32 | 20 | 14.64 | 1680 | 492 | 4.18 / 414.04 | 6 | 66 |
6 | 13 | 303.68 | 20 | 14.88 | 779 | 232 | 4.41 / 414.27 | 6 | 62 |
7 | 13 | 51.52 | 20 | 14.98 | 397 | 119 | 4.53 / 414.39 | 6 | 50 |
8 | 8 | 0.08 | 246 | 14.94 | 304 | 1117 | 5.65 / 415.51 | 6 | 206 |
Average= | 20.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 35 | 14.94 | 443 | 232 | 0.23 / 404.58 | 6 | 14 |
2 | 3 | 1019.40 | 1 | 15.07 | 1771 | 27 | 0.26 / 404.60 | 6 | 46 |
3 | 7 | 2013.20 | 41 | 14.52 | 3079 | 1833 | 2.09 / 406.44 | 46 | 49 |
4 | 13 | 1923.80 | 20 | 14.50 | 2956 | 857 | 2.95 / 407.29 | 6 | 53 |
5 | 13 | 1398.52 | 20 | 14.55 | 2274 | 662 | 3.61 / 407.96 | 6 | 60 |
6 | 13 | 868.12 | 20 | 14.68 | 1553 | 456 | 4.07 / 408.41 | 6 | 68 |
7 | 13 | 212.68 | 20 | 14.92 | 641 | 191 | 4.26 / 408.60 | 6 | 59 |
8 | 13 | 48.44 | 20 | 14.97 | 399 | 119 | 4.38 / 408.72 | 6 | 50 |
9 | 8 | 0.00 | 244 | 14.93 | 312 | 1137 | 5.51 / 409.86 | 6 | 153 |
Average= | 21.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 35 | 14.94 | 444 | 232 | 0.23 / 398.86 | 6 | 14 |
2 | 10 | 1012.28 | 3 | 14.99 | 1735 | 78 | 0.31 / 398.94 | 6 | 52 |
3 | 3 | 965.04 | -1 | 15.37 | 2 | 0 | 0.08 / 398.94 | 6 | 52 |
4 | 7 | 2005.76 | 40 | 14.53 | 3075 | 1787 | 2.10 / 400.73 | 52 | 49 |
5 | 13 | 1921.76 | 20 | 14.51 | 2991 | 868 | 2.97 / 401.59 | 6 | 54 |
6 | 13 | 1828.20 | 20 | 14.45 | 2858 | 826 | 3.79 / 402.42 | 6 | 55 |
7 | 13 | 922.76 | 20 | 14.67 | 1625 | 477 | 4.27 / 402.90 | 6 | 67 |
8 | 13 | 277.80 | 20 | 14.90 | 739 | 220 | 4.49 / 403.12 | 6 | 61 |
9 | 13 | 31.80 | 20 | 14.99 | 361 | 108 | 4.60 / 403.22 | 6 | 50 |
10 | 8 | 0.04 | 246 | 14.94 | 305 | 1121 | 5.72 / 404.35 | 6 | -99 |
Average= | 22.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 35 | 14.95 | 428 | 224 | 0.22 / 393.32 | 6 | 13 |
2 | 7 | 2013.20 | 41 | 14.52 | 3081 | 1834 | 2.06 / 395.16 | 13 | 48 |
3 | 13 | 1927.36 | 20 | 14.50 | 2995 | 869 | 2.93 / 396.02 | 6 | 53 |
4 | 13 | 1506.36 | 20 | 14.53 | 2427 | 705 | 3.63 / 396.73 | 6 | 60 |
5 | 13 | 954.88 | 20 | 14.65 | 1663 | 487 | 4.12 / 397.22 | 6 | 65 |
6 | 13 | 279.76 | 20 | 14.89 | 740 | 220 | 4.34 / 397.44 | 6 | 60 |
7 | 8 | 0.08 | 265 | 14.94 | 301 | 1192 | 5.53 / 398.63 | 6 | -99 |
Average= | 23.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 35 | 14.96 | 456 | 239 | 0.24 / 387.72 | 6 | 13 |
2 | 7 | 2011.32 | 41 | 14.52 | 3085 | 1837 | 2.08 / 389.55 | 13 | 49 |
3 | 13 | 1920.68 | 20 | 14.51 | 2986 | 867 | 2.94 / 390.42 | 6 | 53 |
4 | 13 | 1600.52 | 20 | 14.51 | 2559 | 743 | 3.68 / 391.16 | 6 | 60 |
5 | 13 | 937.80 | 20 | 14.66 | 1643 | 482 | 4.17 / 391.64 | 6 | 65 |
6 | 13 | 368.36 | 20 | 14.86 | 863 | 256 | 4.42 / 391.90 | 6 | 66 |
7 | 8 | 0.00 | 265 | 14.94 | 302 | 1196 | 5.62 / 393.10 | 6 | -99 |
Average= | 24.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 35 | 14.95 | 442 | 231 | 0.23 / 382.22 | 6 | 12 |
2 | 7 | 2006.88 | 40 | 14.54 | 3091 | 1798 | 2.03 / 384.01 | 12 | 48 |
3 | 13 | 1927.48 | 20 | 14.51 | 3000 | 871 | 2.90 / 384.88 | 6 | 52 |
4 | 13 | 1510.20 | 20 | 14.54 | 2422 | 704 | 3.60 / 385.59 | 6 | 59 |
5 | 13 | 967.24 | 20 | 14.66 | 1673 | 491 | 4.09 / 386.08 | 6 | 63 |
6 | 13 | 200.88 | 20 | 14.93 | 627 | 187 | 4.28 / 386.27 | 6 | 57 |
7 | 8 | 0.12 | 265 | 14.95 | 306 | 1212 | 5.49 / 387.48 | 6 | -99 |
Average= | 25.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 35 | 14.96 | 443 | 232 | 0.23 / 376.58 | 6 | 12 |
2 | 7 | 2003.40 | 40 | 14.54 | 3085 | 1794 | 2.03 / 378.38 | 12 | 49 |
3 | 13 | 1908.56 | 20 | 14.52 | 2964 | 861 | 2.89 / 379.24 | 6 | 51 |
4 | 13 | 1567.36 | 20 | 14.53 | 2503 | 727 | 3.61 / 379.96 | 6 | 57 |
5 | 13 | 927.36 | 20 | 14.67 | 1630 | 478 | 4.09 / 380.44 | 6 | 65 |
6 | 13 | 484.96 | 20 | 14.82 | 1026 | 304 | 4.40 / 380.75 | 6 | 65 |
7 | 13 | 23.56 | 20 | 14.99 | 352 | 106 | 4.50 / 380.85 | 6 | 50 |
8 | 8 | 0.16 | 246 | 14.94 | 308 | 1132 | 5.63 / 381.98 | 6 | 174 |
Average= | 27.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 35 | 14.96 | 437 | 229 | 0.23 / 371.05 | 6 | 12 |
2 | 7 | 2014.04 | 40 | 14.53 | 3110 | 1808 | 2.04 / 372.86 | 12 | 49 |
3 | 13 | 1921.84 | 20 | 14.53 | 2991 | 869 | 2.91 / 373.73 | 6 | 52 |
4 | 13 | 1505.88 | 20 | 14.54 | 2432 | 707 | 3.61 / 374.43 | 6 | 60 |
5 | 13 | 973.52 | 20 | 14.66 | 1688 | 495 | 4.11 / 374.93 | 6 | 64 |
6 | 13 | 216.60 | 20 | 14.94 | 649 | 194 | 4.30 / 375.12 | 6 | 59 |
7 | 13 | 51.04 | 20 | 14.99 | 391 | 117 | 4.42 / 375.24 | 6 | 51 |
8 | 8 | 0.04 | 246 | 14.95 | 302 | 1111 | 5.53 / 376.35 | 6 | -99 |
Average= | 28.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 35 | 14.96 | 444 | 232 | 0.23 / 365.46 | 6 | 12 |
2 | 7 | 2004.76 | 41 | 14.54 | 3084 | 1838 | 2.07 / 367.30 | 12 | 48 |
3 | 13 | 1918.68 | 20 | 14.52 | 2978 | 865 | 2.94 / 368.16 | 6 | 52 |
4 | 13 | 1616.64 | 20 | 14.52 | 2566 | 745 | 3.68 / 368.91 | 6 | 58 |
5 | 13 | 844.96 | 20 | 14.71 | 1536 | 452 | 4.13 / 369.36 | 6 | 67 |
6 | 13 | 294.32 | 20 | 14.91 | 764 | 228 | 4.36 / 369.59 | 6 | 62 |
7 | 13 | 33.08 | 20 | 15.00 | 372 | 112 | 4.47 / 369.70 | 6 | 51 |
8 | 8 | 0.12 | 244 | 14.95 | 307 | 1120 | 5.59 / 370.82 | 6 | 155 |
Average= | 30.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 35 | 14.96 | 440 | 230 | 0.23 / 359.77 | 6 | 12 |
2 | 7 | 2009.36 | 40 | 14.54 | 3080 | 1791 | 2.02 / 361.56 | 12 | 48 |
3 | 13 | 1914.44 | 20 | 14.53 | 2982 | 867 | 2.89 / 362.42 | 6 | 53 |
4 | 13 | 1708.72 | 20 | 14.50 | 2690 | 780 | 3.67 / 363.20 | 6 | 57 |
5 | 13 | 1027.40 | 20 | 14.65 | 1771 | 519 | 4.19 / 363.72 | 6 | 65 |
6 | 13 | 361.88 | 20 | 14.88 | 863 | 257 | 4.44 / 363.98 | 6 | 64 |
7 | 13 | 27.28 | 20 | 15.01 | 362 | 109 | 4.55 / 364.09 | 6 | 51 |
8 | 8 | 0.08 | 246 | 14.96 | 310 | 1141 | 5.69 / 365.23 | 6 | -99 |
Average= | 33.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 35 | 14.97 | 429 | 225 | 0.22 / 354.05 | 6 | 12 |
2 | 7 | 2007.92 | 40 | 14.55 | 3079 | 1792 | 2.02 / 355.84 | 12 | 48 |
3 | 13 | 1925.84 | 20 | 14.53 | 2966 | 862 | 2.88 / 356.70 | 6 | 53 |
4 | 13 | 1725.40 | 20 | 14.50 | 2736 | 793 | 3.67 / 357.49 | 6 | 58 |
5 | 13 | 1043.20 | 20 | 14.65 | 1803 | 528 | 4.20 / 358.02 | 6 | 66 |
6 | 13 | 364.76 | 20 | 14.88 | 866 | 258 | 4.46 / 358.28 | 6 | 65 |
7 | 13 | 27.52 | 20 | 15.01 | 362 | 109 | 4.57 / 358.39 | 6 | 51 |
8 | 8 | 0.12 | 246 | 14.96 | 312 | 1148 | 5.71 / 359.54 | 6 | 175 |
Average= | 35.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 35 | 14.98 | 442 | 232 | 0.23 / 348.51 | 6 | 12 |
2 | 7 | 2010.20 | 40 | 14.55 | 3088 | 1797 | 2.03 / 350.31 | 22 | 49 |
3 | 13 | 1918.16 | 20 | 14.53 | 2982 | 867 | 2.90 / 351.17 | 6 | 52 |
4 | 13 | 1483.72 | 20 | 14.56 | 2401 | 699 | 3.59 / 351.87 | 6 | 60 |
5 | 13 | 955.32 | 20 | 14.68 | 1666 | 489 | 4.08 / 352.36 | 6 | 65 |
6 | 13 | 298.04 | 20 | 14.91 | 768 | 229 | 4.31 / 352.59 | 6 | 62 |
7 | 13 | 35.76 | 20 | 15.01 | 373 | 112 | 4.42 / 352.70 | 6 | 52 |
8 | 8 | 0.04 | 246 | 14.96 | 304 | 1119 | 5.54 / 353.82 | 6 | -99 |
Average= | 39.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 35 | 14.99 | 440 | 231 | 0.23 / 342.94 | 6 | 13 |
2 | 7 | 2016.36 | 41 | 14.54 | 3104 | 1850 | 2.08 / 344.79 | 13 | 49 |
3 | 13 | 1948.84 | 20 | 14.52 | 3023 | 878 | 2.96 / 345.66 | 6 | 53 |
4 | 13 | 1522.00 | 20 | 14.55 | 2449 | 713 | 3.67 / 346.38 | 6 | 60 |
5 | 13 | 893.72 | 20 | 14.70 | 1584 | 466 | 4.14 / 346.84 | 6 | 65 |
6 | 13 | 237.00 | 20 | 14.95 | 680 | 203 | 4.34 / 347.05 | 6 | 59 |
7 | 13 | 26.32 | 20 | 15.02 | 360 | 108 | 4.45 / 347.15 | 6 | 50 |
8 | 8 | 0.04 | 246 | 14.97 | 305 | 1123 | 5.57 / 348.28 | 6 | -99 |
Average= | 43.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 35 | 15.00 | 445 | 234 | 0.23 / 337.40 | 6 | 13 |
2 | 7 | 2006.60 | 41 | 14.54 | 3094 | 1844 | 2.08 / 339.25 | 13 | 49 |
3 | 13 | 1932.28 | 20 | 14.53 | 2999 | 872 | 2.95 / 340.12 | 6 | 53 |
4 | 13 | 1521.76 | 20 | 14.56 | 2448 | 713 | 3.66 / 340.83 | 6 | 60 |
5 | 13 | 859.12 | 20 | 14.72 | 1544 | 455 | 4.12 / 341.29 | 6 | 67 |
6 | 13 | 223.64 | 20 | 14.96 | 660 | 197 | 4.31 / 341.48 | 6 | 58 |
7 | 13 | 23.12 | 20 | 15.03 | 350 | 105 | 4.42 / 341.59 | 6 | 49 |
8 | 8 | 0.04 | 244 | 14.98 | 305 | 1115 | 5.53 / 342.70 | 6 | -99 |
Average= | 48.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 35 | 14.99 | 454 | 238 | 0.24 / 331.77 | 6 | 13 |
2 | 10 | 1000.20 | 3 | 15.02 | 1726 | 78 | 0.32 / 331.84 | 6 | 49 |
3 | 3 | 927.96 | -1 | 15.40 | 2 | 0 | 0.08 / 331.84 | 6 | 49 |
4 | 7 | 2017.56 | 40 | 14.55 | 3092 | 1800 | 2.12 / 333.64 | 49 | 48 |
5 | 13 | 1941.80 | 20 | 14.53 | 3000 | 872 | 2.99 / 334.52 | 6 | 52 |
6 | 13 | 1622.28 | 20 | 14.54 | 2570 | 747 | 3.73 / 335.26 | 6 | 57 |
7 | 13 | 1068.84 | 20 | 14.65 | 1825 | 535 | 4.27 / 335.80 | 6 | 65 |
8 | 13 | 188.96 | 20 | 14.98 | 598 | 179 | 4.45 / 335.98 | 6 | 56 |
9 | 8 | 0.04 | 267 | 15.00 | 298 | 1193 | 5.64 / 337.17 | 6 | -99 |
Average= | 56.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 35 | 15.01 | 440 | 231 | 0.23 / 326.29 | 6 | 13 |
2 | 7 | 2008.52 | 40 | 14.56 | 3079 | 1793 | 2.02 / 328.09 | 13 | 48 |
3 | 13 | 1914.32 | 20 | 14.55 | 2939 | 855 | 2.88 / 328.94 | 6 | 52 |
4 | 13 | 1386.04 | 20 | 14.61 | 2256 | 659 | 3.54 / 329.60 | 6 | 61 |
5 | 13 | 870.48 | 20 | 14.73 | 1555 | 458 | 4.00 / 330.06 | 6 | 65 |
6 | 13 | 407.64 | 20 | 14.89 | 919 | 274 | 4.27 / 330.33 | 6 | 66 |
7 | 8 | 0.08 | 265 | 15.00 | 301 | 1196 | 5.47 / 331.53 | 6 | -99 |
Average= | 66.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 35 | 15.00 | 461 | 242 | 0.24 / 320.63 | 6 | 15 |
2 | 7 | 2012.80 | 40 | 14.57 | 3071 | 1790 | 2.03 / 322.42 | 46 | 48 |
3 | 13 | 1928.64 | 20 | 14.55 | 2983 | 868 | 2.90 / 323.29 | 6 | 53 |
4 | 13 | 1725.20 | 20 | 14.52 | 2729 | 793 | 3.69 / 324.08 | 6 | 58 |
5 | 13 | 1167.48 | 20 | 14.63 | 1969 | 576 | 4.27 / 324.66 | 6 | 65 |
6 | 13 | 236.08 | 20 | 14.98 | 683 | 205 | 4.47 / 324.86 | 6 | 58 |
7 | 8 | 0.08 | 265 | 15.01 | 301 | 1197 | 5.67 / 326.06 | 6 | -99 |
Average= | 81.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 35 | 15.02 | 439 | 231 | 0.23 / 314.89 | 6 | 14 |
2 | 7 | 2010.04 | 40 | 14.56 | 3097 | 1804 | 2.03 / 316.70 | 14 | 49 |
3 | 13 | 1931.88 | 20 | 14.55 | 2990 | 870 | 2.90 / 317.57 | 6 | 52 |
4 | 13 | 1725.68 | 20 | 14.53 | 2722 | 791 | 3.70 / 318.36 | 6 | 57 |
5 | 13 | 826.96 | 20 | 14.76 | 1498 | 442 | 4.14 / 318.80 | 6 | 66 |
6 | 13 | 614.40 | 20 | 14.82 | 1201 | 356 | 4.49 / 319.16 | 6 | 67 |
7 | 8 | 0.08 | 267 | 15.01 | 308 | 1234 | 5.73 / 320.39 | 6 | -99 |
Average= | 106.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 35 | 15.01 | 458 | 241 | 0.24 / 309.41 | 6 | 13 |
2 | 7 | 2014.04 | 40 | 14.56 | 3093 | 1801 | 2.04 / 311.21 | 34 | 48 |
3 | 13 | 1939.32 | 20 | 14.55 | 2998 | 872 | 2.91 / 312.08 | 6 | 53 |
4 | 13 | 1513.04 | 20 | 14.58 | 2424 | 707 | 3.62 / 312.79 | 6 | 59 |
5 | 13 | 954.64 | 20 | 14.72 | 1643 | 484 | 4.10 / 313.27 | 6 | 65 |
6 | 13 | 207.00 | 20 | 15.00 | 634 | 190 | 4.30 / 313.46 | 6 | 56 |
7 | 8 | 0.04 | 265 | 15.02 | 301 | 1198 | 5.49 / 314.66 | 6 | -99 |
Average= | 157.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 35 | 15.03 | 437 | 230 | 0.23 / 303.76 | 6 | 13 |
2 | 7 | 2016.88 | 40 | 14.56 | 3099 | 1805 | 2.03 / 305.56 | 13 | 50 |
3 | 13 | 1941.20 | 20 | 14.55 | 3010 | 876 | 2.91 / 306.44 | 6 | 52 |
4 | 13 | 1535.28 | 20 | 14.58 | 2476 | 722 | 3.63 / 307.16 | 6 | 61 |
5 | 13 | 887.32 | 20 | 14.75 | 1577 | 465 | 4.10 / 307.62 | 6 | 66 |
6 | 13 | 444.24 | 20 | 14.91 | 964 | 287 | 4.39 / 307.91 | 6 | 65 |
7 | 13 | 39.24 | 20 | 15.05 | 385 | 116 | 4.50 / 308.03 | 6 | 51 |
8 | 8 | -0.04 | 246 | 15.01 | 309 | 1141 | 5.64 / 309.17 | 6 | -99 |
Average= | 309.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 35 | 15.03 | 460 | 242 | 0.24 / 298.07 | 6 | 13 |
2 | 3 | 1020.60 | 1 | 15.13 | 1776 | 27 | 0.27 / 298.10 | 6 | 49 |
3 | 7 | 2010.52 | 40 | 14.57 | 3089 | 1800 | 2.07 / 299.90 | 49 | 50 |
4 | 13 | 1915.92 | 20 | 14.56 | 2967 | 864 | 2.93 / 300.76 | 6 | 53 |
5 | 13 | 1586.64 | 20 | 14.57 | 2535 | 739 | 3.67 / 301.50 | 6 | 59 |
6 | 13 | 1031.80 | 20 | 14.70 | 1777 | 522 | 4.19 / 302.02 | 6 | 64 |
7 | 13 | 450.44 | 20 | 14.91 | 977 | 291 | 4.49 / 302.32 | 6 | 67 |
8 | 8 | 0.16 | 265 | 15.03 | 304 | 1211 | 5.70 / 303.53 | 6 | -99 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 35 | 15.05 | 473 | 249 | 0.25 / 292.50 | 6 | 12 |
2 | 7 | 2008.12 | 40 | 14.57 | 3087 | 1799 | 2.05 / 294.30 | 12 | 49 |
3 | 13 | 1928.72 | 20 | 14.56 | 2982 | 868 | 2.92 / 295.17 | 6 | 52 |
4 | 13 | 1616.08 | 20 | 14.57 | 2567 | 748 | 3.66 / 295.92 | 6 | 58 |
5 | 13 | 871.48 | 20 | 14.78 | 1538 | 455 | 4.12 / 296.37 | 6 | 65 |
6 | 13 | 313.40 | 20 | 14.98 | 786 | 235 | 4.35 / 296.61 | 6 | 62 |
7 | 13 | 16.16 | 20 | 15.09 | 336 | 101 | 4.46 / 296.71 | 6 | 50 |
8 | 8 | 0.12 | 244 | 15.04 | 306 | 1123 | 5.58 / 297.83 | 6 | 160 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 35 | 15.05 | 452 | 238 | 0.24 / 286.95 | 6 | 13 |
2 | 7 | 2010.56 | 40 | 14.58 | 3068 | 1789 | 2.03 / 288.73 | 13 | 48 |
3 | 13 | 1926.72 | 20 | 14.57 | 2990 | 871 | 2.90 / 289.61 | 6 | 52 |
4 | 13 | 1592.24 | 20 | 14.59 | 2527 | 737 | 3.64 / 290.34 | 6 | 58 |
5 | 13 | 928.64 | 20 | 14.76 | 1644 | 485 | 4.12 / 290.83 | 6 | 66 |
6 | 13 | 93.76 | 20 | 15.08 | 466 | 141 | 4.26 / 290.97 | 6 | 50 |
7 | 8 | 0.04 | 263 | 15.05 | 324 | 1282 | 5.54 / 292.25 | 6 | 137 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 35 | 15.05 | 446 | 235 | 0.23 / 281.44 | 6 | 15 |
2 | 7 | 2008.16 | 40 | 14.58 | 3067 | 1789 | 2.02 / 283.22 | 15 | 49 |
3 | 13 | 1928.44 | 20 | 14.57 | 2989 | 871 | 2.89 / 284.10 | 6 | 53 |
4 | 13 | 1417.84 | 20 | 14.63 | 2316 | 678 | 3.57 / 284.77 | 6 | 61 |
5 | 13 | 992.52 | 20 | 14.74 | 1720 | 507 | 4.08 / 285.28 | 6 | 65 |
6 | 13 | 112.64 | 20 | 15.08 | 492 | 148 | 4.23 / 285.43 | 6 | 54 |
7 | 8 | 0.16 | 263 | 15.05 | 323 | 1278 | 5.51 / 286.71 | 6 | -99 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 35 | 15.06 | 452 | 238 | 0.24 / 275.91 | 6 | 15 |
2 | 3 | 1019.84 | 1 | 15.14 | 1770 | 27 | 0.27 / 275.93 | 6 | 42 |
3 | 7 | 2012.24 | 40 | 14.58 | 3092 | 1803 | 2.07 / 277.74 | 42 | 48 |
4 | 13 | 1928.64 | 20 | 14.57 | 2999 | 874 | 2.94 / 278.61 | 6 | 53 |
5 | 13 | 1413.16 | 20 | 14.64 | 2301 | 674 | 3.62 / 279.28 | 6 | 60 |
6 | 13 | 789.20 | 20 | 14.82 | 1445 | 428 | 4.04 / 279.71 | 6 | 66 |
7 | 13 | 233.36 | 20 | 15.03 | 679 | 204 | 4.25 / 279.92 | 6 | 62 |
8 | 13 | 49.72 | 20 | 15.09 | 403 | 122 | 4.37 / 280.04 | 6 | 53 |
9 | 8 | 0.12 | 244 | 15.05 | 317 | 1164 | 5.53 / 281.20 | 6 | -99 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 35 | 15.06 | 446 | 235 | 0.24 / 270.30 | 6 | 14 |
2 | 7 | 2006.88 | 40 | 14.59 | 3086 | 1801 | 2.04 / 272.10 | 14 | 49 |
3 | 13 | 1920.60 | 20 | 14.58 | 2986 | 871 | 2.91 / 272.97 | 6 | 53 |
4 | 13 | 1496.28 | 20 | 14.62 | 2413 | 706 | 3.61 / 273.67 | 6 | 59 |
5 | 13 | 951.24 | 20 | 14.76 | 1674 | 494 | 4.11 / 274.17 | 6 | 66 |
6 | 13 | 391.72 | 20 | 14.97 | 908 | 272 | 4.38 / 274.44 | 6 | 67 |
7 | 8 | 0.04 | 263 | 15.06 | 310 | 1228 | 5.61 / 275.67 | 6 | -99 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 35 | 15.06 | 444 | 234 | 0.23 / 264.91 | 6 | 15 |
2 | 7 | 2010.72 | 40 | 14.58 | 3095 | 1805 | 2.04 / 266.71 | 15 | 50 |
3 | 13 | 1935.12 | 20 | 14.57 | 2998 | 874 | 2.91 / 267.58 | 6 | 52 |
4 | 13 | 1309.60 | 20 | 14.68 | 2152 | 632 | 3.54 / 268.22 | 6 | 62 |
5 | 13 | 886.72 | 20 | 14.80 | 1567 | 464 | 4.01 / 268.68 | 6 | 65 |
6 | 13 | 124.88 | 20 | 15.08 | 519 | 157 | 4.16 / 268.84 | 6 | 53 |
7 | 8 | 0.04 | 263 | 15.07 | 309 | 1225 | 5.39 / 270.06 | 6 | -99 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 35 | 15.07 | 444 | 234 | 0.23 / 259.40 | 6 | 16 |
2 | 7 | 2007.76 | 40 | 14.59 | 3092 | 1804 | 2.04 / 261.20 | 30 | 49 |
3 | 13 | 1919.00 | 20 | 14.58 | 2984 | 870 | 2.91 / 262.07 | 6 | 54 |
4 | 13 | 1398.12 | 20 | 14.66 | 2290 | 671 | 3.58 / 262.74 | 6 | 62 |
5 | 13 | 860.12 | 20 | 14.81 | 1554 | 460 | 4.04 / 263.20 | 6 | 67 |
6 | 13 | 305.80 | 20 | 15.01 | 789 | 237 | 4.28 / 263.44 | 6 | 64 |
7 | 8 | 0.08 | 263 | 15.07 | 311 | 1233 | 5.51 / 264.67 | 6 | -99 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 34 | 15.08 | 461 | 236 | 0.24 / 253.68 | 6 | 16 |
2 | 7 | 2011.96 | 40 | 14.60 | 3088 | 1803 | 2.04 / 255.49 | 16 | 50 |
3 | 13 | 1923.16 | 20 | 14.58 | 2992 | 872 | 2.91 / 256.36 | 6 | 54 |
4 | 13 | 1719.48 | 20 | 14.57 | 2711 | 790 | 3.70 / 257.15 | 6 | 57 |
5 | 13 | 1146.64 | 20 | 14.71 | 1939 | 570 | 4.27 / 257.72 | 6 | 64 |
6 | 13 | 217.28 | 20 | 15.05 | 660 | 199 | 4.47 / 257.92 | 6 | 61 |
7 | 8 | 0.12 | 263 | 15.08 | 313 | 1241 | 5.71 / 259.16 | 6 | 185 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 35 | 15.09 | 455 | 240 | 0.24 / 248.19 | 6 | 15 |
2 | 7 | 2003.72 | 40 | 14.59 | 3084 | 1800 | 2.04 / 249.99 | 15 | 49 |
3 | 13 | 1911.08 | 20 | 14.59 | 2973 | 868 | 2.91 / 250.86 | 6 | 53 |
4 | 13 | 1373.96 | 20 | 14.68 | 2239 | 657 | 3.57 / 251.52 | 6 | 61 |
5 | 13 | 1054.08 | 20 | 14.75 | 1798 | 530 | 4.10 / 252.05 | 6 | 64 |
6 | 13 | 164.64 | 20 | 15.09 | 578 | 174 | 4.27 / 252.22 | 6 | 56 |
7 | 8 | 0.16 | 263 | 15.08 | 309 | 1226 | 5.50 / 253.45 | 6 | -99 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 35 | 15.09 | 449 | 237 | 0.24 / 242.59 | 6 | 15 |
2 | 7 | 2008.20 | 40 | 14.59 | 3095 | 1806 | 2.04 / 244.40 | 15 | 49 |
3 | 13 | 1926.04 | 20 | 14.58 | 2994 | 873 | 2.92 / 245.27 | 6 | 55 |
4 | 13 | 1608.48 | 20 | 14.60 | 2570 | 750 | 3.67 / 246.02 | 6 | 59 |
5 | 13 | 925.96 | 20 | 14.80 | 1642 | 486 | 4.15 / 246.51 | 6 | 66 |
6 | 13 | 234.96 | 20 | 15.06 | 686 | 207 | 4.36 / 246.72 | 6 | 61 |
7 | 8 | 0.16 | 261 | 15.09 | 314 | 1237 | 5.60 / 247.95 | 6 | 134 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 35 | 15.09 | 456 | 241 | 0.24 / 237.11 | 6 | 18 |
2 | 7 | 2009.00 | 40 | 14.59 | 3098 | 1808 | 2.05 / 238.92 | 18 | 49 |
3 | 13 | 1933.56 | 20 | 14.58 | 3008 | 877 | 2.93 / 239.79 | 6 | 53 |
4 | 13 | 1413.76 | 20 | 14.66 | 2311 | 678 | 3.60 / 240.47 | 6 | 60 |
5 | 13 | 773.12 | 20 | 14.86 | 1422 | 423 | 4.03 / 240.90 | 6 | 65 |
6 | 13 | 338.08 | 20 | 15.02 | 828 | 249 | 4.27 / 241.14 | 6 | 65 |
7 | 8 | 0.16 | 261 | 15.09 | 308 | 1213 | 5.49 / 242.36 | 6 | 138 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 35 | 15.10 | 458 | 242 | 0.24 / 231.68 | 6 | 14 |
2 | 7 | 2014.68 | 40 | 14.60 | 3099 | 1810 | 2.05 / 233.48 | 14 | 49 |
3 | 13 | 1939.48 | 20 | 14.59 | 3015 | 880 | 2.93 / 234.36 | 6 | 53 |
4 | 13 | 1316.04 | 20 | 14.70 | 2174 | 639 | 3.57 / 235.00 | 6 | 62 |
5 | 13 | 990.24 | 20 | 14.79 | 1703 | 504 | 4.07 / 235.51 | 6 | 65 |
6 | 13 | 127.48 | 20 | 15.12 | 510 | 154 | 4.23 / 235.66 | 6 | 53 |
7 | 8 | 0.20 | 263 | 15.10 | 304 | 1207 | 5.44 / 236.87 | 6 | -99 |
Average= | 5.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 35 | 15.10 | 456 | 241 | 0.24 / 226.01 | 6 | 17 |
2 | 7 | 2010.12 | 40 | 14.60 | 3108 | 1815 | 2.06 / 227.82 | 17 | 50 |
3 | 13 | 1924.68 | 20 | 14.59 | 2987 | 872 | 2.93 / 228.70 | 6 | 53 |
4 | 13 | 1517.40 | 20 | 14.64 | 2437 | 714 | 3.64 / 229.41 | 6 | 60 |
5 | 13 | 1178.52 | 20 | 14.71 | 1990 | 585 | 4.23 / 230.00 | 6 | 66 |
6 | 13 | 238.52 | 20 | 15.07 | 685 | 206 | 4.43 / 230.20 | 6 | 59 |
7 | 8 | 0.04 | 263 | 15.10 | 310 | 1231 | 5.66 / 231.43 | 6 | -99 |
Average= | 5.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 35 | 15.11 | 450 | 238 | 0.24 / 220.47 | 6 | 15 |
2 | 7 | 2006.64 | 40 | 14.60 | 3085 | 1802 | 2.04 / 222.27 | 15 | 49 |
3 | 13 | 1925.24 | 20 | 14.59 | 2988 | 872 | 2.91 / 223.14 | 6 | 54 |
4 | 13 | 1397.88 | 20 | 14.69 | 2284 | 671 | 3.58 / 223.81 | 6 | 61 |
5 | 13 | 978.08 | 20 | 14.80 | 1706 | 505 | 4.09 / 224.32 | 6 | 68 |
6 | 13 | 281.96 | 20 | 15.06 | 747 | 225 | 4.31 / 224.54 | 6 | 62 |
7 | 8 | 0.12 | 263 | 15.10 | 309 | 1227 | 5.54 / 225.77 | 6 | -99 |
Average= | 5.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 35 | 15.11 | 451 | 239 | 0.24 / 214.95 | 6 | 13 |
2 | 7 | 2011.44 | 40 | 14.61 | 3097 | 1810 | 2.05 / 216.76 | 13 | 49 |
3 | 13 | 1932.16 | 20 | 14.61 | 2993 | 875 | 2.92 / 217.64 | 6 | 53 |
4 | 13 | 1515.84 | 20 | 14.65 | 2448 | 717 | 3.64 / 218.35 | 6 | 60 |
5 | 13 | 869.96 | 20 | 14.84 | 1566 | 465 | 4.11 / 218.82 | 6 | 67 |
6 | 13 | 215.80 | 20 | 15.09 | 655 | 198 | 4.30 / 219.02 | 6 | 56 |
7 | 8 | 0.20 | 263 | 15.12 | 305 | 1213 | 5.52 / 220.23 | 6 | -99 |
Average= | 5.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 34 | 15.11 | 456 | 234 | 0.23 / 209.28 | 6 | 14 |
2 | 7 | 2013.72 | 40 | 14.62 | 3100 | 1813 | 2.05 / 211.09 | 14 | 49 |
3 | 13 | 1940.16 | 20 | 14.60 | 3006 | 878 | 2.92 / 211.97 | 6 | 52 |
4 | 13 | 1622.80 | 20 | 14.63 | 2591 | 758 | 3.68 / 212.73 | 6 | 58 |
5 | 13 | 969.56 | 20 | 14.81 | 1686 | 499 | 4.18 / 213.23 | 6 | 64 |
6 | 13 | 317.80 | 20 | 15.06 | 800 | 241 | 4.42 / 213.47 | 6 | 61 |
7 | 8 | 0.20 | 265 | 15.12 | 311 | 1246 | 5.67 / 214.71 | 6 | -99 |
Average= | 5.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 34 | 15.12 | 440 | 226 | 0.23 / 203.66 | 6 | 14 |
2 | 7 | 2005.96 | 40 | 14.62 | 3084 | 1804 | 2.03 / 205.47 | 14 | 49 |
3 | 13 | 1922.20 | 20 | 14.61 | 2988 | 873 | 2.90 / 206.34 | 6 | 53 |
4 | 13 | 1410.68 | 20 | 14.70 | 2303 | 677 | 3.58 / 207.02 | 6 | 62 |
5 | 13 | 970.76 | 20 | 14.82 | 1690 | 501 | 4.08 / 207.52 | 6 | 67 |
6 | 13 | 293.36 | 20 | 15.07 | 766 | 231 | 4.31 / 207.75 | 6 | 60 |
7 | 8 | 0.16 | 263 | 15.11 | 326 | 1296 | 5.61 / 209.04 | 6 | 152 |
Average= | 5.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 34 | 15.13 | 447 | 230 | 0.23 / 198.14 | 6 | 15 |
2 | 7 | 2014.92 | 40 | 14.61 | 3096 | 1809 | 2.04 / 199.95 | 15 | 50 |
3 | 13 | 1935.24 | 20 | 14.61 | 3000 | 877 | 2.92 / 200.82 | 6 | 52 |
4 | 13 | 1413.04 | 20 | 14.70 | 2302 | 677 | 3.59 / 201.50 | 6 | 62 |
5 | 13 | 963.52 | 20 | 14.82 | 1681 | 498 | 4.09 / 202.00 | 6 | 68 |
6 | 13 | 294.36 | 20 | 15.07 | 765 | 231 | 4.32 / 202.23 | 6 | 61 |
7 | 8 | 0.08 | 263 | 15.12 | 304 | 1209 | 5.53 / 203.44 | 6 | -99 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 34 | 15.13 | 454 | 234 | 0.23 / 192.67 | 6 | 12 |
2 | 7 | 2015.92 | 41 | 14.61 | 3102 | 1858 | 2.09 / 194.52 | 12 | 50 |
3 | 13 | 1931.68 | 20 | 14.61 | 2991 | 874 | 2.97 / 195.40 | 6 | 54 |
4 | 13 | 1422.28 | 20 | 14.70 | 2318 | 681 | 3.65 / 196.08 | 6 | 61 |
5 | 13 | 906.84 | 20 | 14.85 | 1610 | 478 | 4.13 / 196.56 | 6 | 66 |
6 | 13 | 150.04 | 20 | 15.14 | 552 | 167 | 4.29 / 196.73 | 6 | 53 |
7 | 8 | 0.04 | 261 | 15.14 | 299 | 1182 | 5.47 / 197.91 | 6 | -99 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 34 | 15.14 | 453 | 233 | 0.23 / 187.10 | 6 | 12 |
2 | 7 | 2013.84 | 40 | 14.62 | 3097 | 1811 | 2.04 / 188.91 | 12 | 49 |
3 | 13 | 1936.28 | 20 | 14.61 | 3019 | 882 | 2.93 / 189.79 | 6 | 53 |
4 | 13 | 1510.52 | 20 | 14.68 | 2430 | 713 | 3.64 / 190.50 | 6 | 60 |
5 | 13 | 983.64 | 20 | 14.83 | 1692 | 502 | 4.14 / 191.00 | 6 | 65 |
6 | 13 | 207.40 | 20 | 15.12 | 640 | 194 | 4.34 / 191.20 | 6 | 57 |
7 | 8 | 0.12 | 263 | 15.14 | 310 | 1234 | 5.57 / 192.43 | 6 | -99 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 34 | 15.15 | 441 | 227 | 0.23 / 181.54 | 6 | 13 |
2 | 7 | 2011.52 | 40 | 14.63 | 3079 | 1802 | 2.03 / 183.34 | 13 | 51 |
3 | 13 | 1923.64 | 20 | 14.62 | 2982 | 872 | 2.90 / 184.22 | 6 | 53 |
4 | 13 | 1497.44 | 20 | 14.69 | 2412 | 709 | 3.61 / 184.93 | 6 | 61 |
5 | 13 | 1052.16 | 20 | 14.81 | 1790 | 530 | 4.14 / 185.46 | 6 | 62 |
6 | 13 | 174.36 | 20 | 15.14 | 590 | 179 | 4.32 / 185.63 | 6 | 57 |
7 | 13 | 38.64 | 20 | 15.18 | 373 | 113 | 4.43 / 185.75 | 6 | 47 |
8 | 8 | 0.08 | 244 | 15.14 | 302 | 1116 | 5.55 / 186.86 | 6 | -99 |
Average= | 5.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 34 | 15.14 | 445 | 229 | 0.23 / 176.03 | 6 | 11 |
2 | 7 | 2003.64 | 40 | 14.64 | 3085 | 1807 | 2.04 / 177.83 | 11 | 51 |
3 | 13 | 1920.40 | 20 | 14.63 | 2987 | 874 | 2.91 / 178.71 | 6 | 53 |
4 | 13 | 1602.04 | 20 | 14.66 | 2560 | 751 | 3.66 / 179.46 | 6 | 60 |
5 | 13 | 835.00 | 20 | 14.89 | 1519 | 452 | 4.11 / 179.91 | 6 | 67 |
6 | 13 | 102.52 | 20 | 15.17 | 483 | 147 | 4.26 / 180.06 | 6 | 51 |
7 | 8 | 0.16 | 263 | 15.15 | 316 | 1259 | 5.52 / 181.32 | 6 | -99 |
Average= | 5.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 34 | 15.14 | 457 | 235 | 0.24 / 170.48 | 6 | 11 |
2 | 7 | 2012.24 | 40 | 14.64 | 3077 | 1802 | 2.04 / 172.29 | 11 | 49 |
3 | 13 | 1920.56 | 20 | 14.64 | 2967 | 869 | 2.91 / 173.15 | 6 | 54 |
4 | 13 | 1485.24 | 20 | 14.70 | 2397 | 705 | 3.61 / 173.86 | 6 | 60 |
5 | 13 | 848.88 | 20 | 14.90 | 1528 | 455 | 4.07 / 174.32 | 6 | 68 |
6 | 13 | 291.64 | 20 | 15.10 | 770 | 233 | 4.30 / 174.55 | 6 | 63 |
7 | 13 | 32.44 | 20 | 15.18 | 369 | 112 | 4.41 / 174.66 | 6 | 52 |
8 | 8 | 0.04 | 244 | 15.14 | 308 | 1138 | 5.55 / 175.80 | 6 | -99 |
Average= | 5.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 34 | 15.16 | 458 | 236 | 0.24 / 164.79 | 6 | 10 |
2 | 7 | 2009.08 | 40 | 14.64 | 3094 | 1812 | 2.05 / 166.60 | 10 | 48 |
3 | 13 | 1911.00 | 20 | 14.64 | 2968 | 869 | 2.92 / 167.47 | 6 | 54 |
4 | 13 | 1583.28 | 20 | 14.68 | 2526 | 742 | 3.66 / 168.21 | 6 | 59 |
5 | 13 | 1025.72 | 20 | 14.83 | 1759 | 522 | 4.18 / 168.73 | 6 | 64 |
6 | 13 | 354.88 | 20 | 15.07 | 866 | 261 | 4.44 / 168.99 | 6 | 64 |
7 | 13 | 23.12 | 20 | 15.19 | 364 | 111 | 4.55 / 169.10 | 6 | 49 |
8 | 8 | 0.08 | 242 | 15.15 | 313 | 1148 | 5.70 / 170.25 | 6 | 162 |
Average= | 5.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 34 | 15.16 | 447 | 230 | 0.23 / 159.27 | 6 | 11 |
2 | 7 | 2004.88 | 40 | 14.65 | 3095 | 1814 | 2.04 / 161.09 | 11 | 50 |
3 | 13 | 1920.20 | 20 | 14.64 | 2986 | 874 | 2.92 / 161.96 | 6 | 54 |
4 | 13 | 1478.00 | 20 | 14.71 | 2397 | 705 | 3.62 / 162.67 | 6 | 61 |
5 | 13 | 962.24 | 20 | 14.86 | 1687 | 501 | 4.12 / 163.17 | 6 | 67 |
6 | 13 | 110.12 | 20 | 15.18 | 492 | 149 | 4.27 / 163.32 | 6 | 51 |
7 | 13 | 24.80 | 20 | 15.20 | 360 | 109 | 4.38 / 163.43 | 6 | 48 |
8 | 8 | 0.04 | 242 | 15.16 | 306 | 1123 | 5.51 / 164.55 | 6 | 215 |
Average= | 5.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 34 | 15.17 | 441 | 227 | 0.23 / 153.78 | 6 | 11 |
2 | 7 | 2006.04 | 40 | 14.66 | 3089 | 1811 | 2.04 / 155.59 | 11 | 51 |
3 | 13 | 1911.00 | 20 | 14.66 | 2958 | 867 | 2.91 / 156.46 | 6 | 52 |
4 | 13 | 1395.80 | 20 | 14.76 | 2267 | 669 | 3.58 / 157.13 | 6 | 61 |
5 | 13 | 969.12 | 20 | 14.86 | 1703 | 506 | 4.08 / 157.63 | 6 | 67 |
6 | 13 | 188.60 | 20 | 15.15 | 611 | 185 | 4.27 / 157.82 | 6 | 56 |
7 | 8 | 0.20 | 261 | 15.16 | 310 | 1227 | 5.49 / 159.04 | 6 | -99 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 34 | 15.17 | 438 | 226 | 0.23 / 148.38 | 6 | 13 |
2 | 7 | 2005.88 | 40 | 14.66 | 3052 | 1790 | 2.02 / 150.17 | 13 | 50 |
3 | 13 | 1916.84 | 20 | 14.65 | 2977 | 872 | 2.89 / 151.05 | 6 | 54 |
4 | 13 | 1391.72 | 20 | 14.75 | 2268 | 669 | 3.56 / 151.71 | 6 | 62 |
5 | 13 | 945.00 | 20 | 14.87 | 1665 | 495 | 4.05 / 152.21 | 6 | 68 |
6 | 13 | 91.08 | 20 | 15.20 | 462 | 140 | 4.19 / 152.35 | 6 | 51 |
7 | 8 | 0.12 | 261 | 15.17 | 303 | 1200 | 5.39 / 153.55 | 6 | -99 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 34 | 15.16 | 470 | 242 | 0.24 / 142.81 | 6 | 12 |
2 | 7 | 2007.52 | 40 | 14.65 | 3088 | 1810 | 2.05 / 144.62 | 12 | 50 |
3 | 13 | 1923.24 | 20 | 14.65 | 2982 | 874 | 2.93 / 145.49 | 6 | 54 |
4 | 13 | 1623.24 | 20 | 14.68 | 2582 | 758 | 3.68 / 146.25 | 6 | 59 |
5 | 13 | 872.48 | 20 | 14.91 | 1563 | 466 | 4.15 / 146.72 | 6 | 65 |
6 | 13 | 121.92 | 20 | 15.19 | 514 | 156 | 4.31 / 146.87 | 6 | 51 |
7 | 13 | 27.76 | 20 | 15.21 | 362 | 110 | 4.42 / 146.98 | 6 | 49 |
8 | 8 | 0.08 | 242 | 15.17 | 320 | 1175 | 5.59 / 148.16 | 6 | 173 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 34 | 15.17 | 460 | 237 | 0.24 / 137.14 | 6 | 12 |
2 | 7 | 2003.28 | 40 | 14.65 | 3098 | 1815 | 2.05 / 138.96 | 12 | 49 |
3 | 13 | 1909.24 | 20 | 14.66 | 2968 | 870 | 2.92 / 139.83 | 6 | 54 |
4 | 13 | 1472.68 | 20 | 14.73 | 2383 | 702 | 3.62 / 140.53 | 6 | 61 |
5 | 13 | 929.84 | 20 | 14.89 | 1636 | 487 | 4.11 / 141.02 | 6 | 67 |
6 | 13 | 238.32 | 20 | 15.14 | 692 | 210 | 4.32 / 141.23 | 6 | 62 |
7 | 13 | 24.24 | 20 | 15.21 | 369 | 112 | 4.43 / 141.34 | 6 | 50 |
8 | 8 | 0.12 | 242 | 15.16 | 335 | 1229 | 5.66 / 142.57 | 6 | -99 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 34 | 15.16 | 472 | 243 | 0.24 / 131.56 | 6 | 13 |
2 | 7 | 2012.84 | 40 | 14.66 | 3100 | 1818 | 2.06 / 133.38 | 26 | 49 |
3 | 13 | 1927.88 | 20 | 14.66 | 3002 | 880 | 2.94 / 134.26 | 6 | 53 |
4 | 13 | 1394.72 | 20 | 14.76 | 2278 | 672 | 3.61 / 134.93 | 6 | 61 |
5 | 13 | 1054.08 | 20 | 14.85 | 1795 | 533 | 4.15 / 135.47 | 6 | 65 |
6 | 13 | 85.12 | 20 | 15.21 | 452 | 137 | 4.28 / 135.60 | 6 | 51 |
7 | 8 | 0.08 | 263 | 15.18 | 326 | 1302 | 5.59 / 136.90 | 6 | -99 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 34 | 15.17 | 469 | 242 | 0.24 / 125.65 | 6 | 14 |
2 | 7 | 2017.52 | 40 | 14.66 | 3118 | 1828 | 2.07 / 127.48 | 14 | 49 |
3 | 13 | 1929.24 | 20 | 14.66 | 3005 | 881 | 2.95 / 128.36 | 6 | 52 |
4 | 13 | 1635.44 | 20 | 14.69 | 2610 | 767 | 3.72 / 129.13 | 6 | 60 |
5 | 13 | 1064.00 | 20 | 14.85 | 1835 | 545 | 4.26 / 129.67 | 6 | 67 |
6 | 13 | 474.76 | 20 | 15.05 | 1020 | 307 | 4.57 / 129.98 | 6 | 69 |
7 | 8 | 0.16 | 265 | 15.17 | 333 | 1339 | 5.91 / 131.32 | 6 | -99 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 34 | 15.18 | 455 | 235 | 0.23 / 119.87 | 6 | 13 |
2 | 7 | 2004.44 | 41 | 14.67 | 3071 | 1847 | 2.08 / 121.72 | 13 | 49 |
3 | 13 | 1920.76 | 20 | 14.67 | 2988 | 877 | 2.96 / 122.59 | 6 | 53 |
4 | 13 | 1598.28 | 20 | 14.71 | 2552 | 751 | 3.71 / 123.35 | 6 | 59 |
5 | 13 | 942.04 | 20 | 14.91 | 1637 | 488 | 4.20 / 123.83 | 6 | 65 |
6 | 13 | 352.48 | 20 | 15.11 | 857 | 259 | 4.46 / 124.09 | 6 | 64 |
7 | 8 | 0.16 | 263 | 15.17 | 330 | 1317 | 5.77 / 125.41 | 6 | -99 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 34 | 15.19 | 446 | 230 | 0.23 / 114.24 | 6 | 12 |
2 | 7 | 2009.72 | 40 | 14.67 | 3096 | 1817 | 2.05 / 116.06 | 12 | 50 |
3 | 13 | 1931.80 | 20 | 14.67 | 3004 | 881 | 2.93 / 116.94 | 6 | 54 |
4 | 13 | 1628.80 | 20 | 14.70 | 2585 | 760 | 3.69 / 117.70 | 6 | 59 |
5 | 13 | 978.76 | 20 | 14.89 | 1678 | 500 | 4.19 / 118.20 | 6 | 65 |
6 | 13 | 189.80 | 20 | 15.18 | 620 | 188 | 4.38 / 118.39 | 6 | 60 |
7 | 8 | 0.04 | 263 | 15.19 | 312 | 1246 | 5.62 / 119.64 | 6 | -99 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 34 | 15.19 | 466 | 241 | 0.24 / 108.87 | 6 | 15 |
2 | 7 | 2003.60 | 40 | 14.68 | 3092 | 1816 | 2.06 / 110.69 | 15 | 50 |
3 | 13 | 1916.76 | 20 | 14.68 | 2978 | 874 | 2.93 / 111.56 | 6 | 53 |
4 | 13 | 1183.60 | 20 | 14.85 | 1994 | 592 | 3.52 / 112.16 | 6 | 62 |
5 | 13 | 980.04 | 20 | 14.89 | 1700 | 506 | 4.03 / 112.66 | 6 | 66 |
6 | 13 | 103.00 | 20 | 15.22 | 481 | 146 | 4.18 / 112.81 | 6 | 51 |
7 | 8 | 0.08 | 259 | 15.20 | 306 | 1205 | 5.38 / 114.01 | 6 | 141 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 34 | 15.19 | 450 | 232 | 0.23 / 103.53 | 6 | 12 |
2 | 7 | 2005.68 | 40 | 14.68 | 3095 | 1817 | 2.05 / 105.35 | 12 | 50 |
3 | 13 | 1917.56 | 20 | 14.69 | 2990 | 878 | 2.93 / 106.23 | 6 | 53 |
4 | 13 | 1289.52 | 20 | 14.82 | 2130 | 631 | 3.56 / 106.86 | 6 | 63 |
5 | 13 | 684.36 | 20 | 15.01 | 1296 | 389 | 3.95 / 107.25 | 6 | 66 |
6 | 13 | 144.72 | 20 | 15.21 | 544 | 165 | 4.11 / 107.41 | 6 | 55 |
7 | 8 | 0.28 | 259 | 15.20 | 310 | 1220 | 5.33 / 108.63 | 6 | -99 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 34 | 15.19 | 464 | 240 | 0.24 / 97.99 | 6 | 16 |
2 | 7 | 2003.20 | 40 | 14.70 | 3078 | 1810 | 2.05 / 99.80 | 16 | 48 |
3 | 13 | 1908.88 | 20 | 14.70 | 2973 | 874 | 2.92 / 100.67 | 6 | 53 |
4 | 13 | 1394.20 | 20 | 14.80 | 2276 | 674 | 3.60 / 101.34 | 6 | 61 |
5 | 13 | 958.44 | 20 | 14.91 | 1671 | 498 | 4.10 / 101.84 | 6 | 65 |
6 | 13 | 275.32 | 20 | 15.16 | 747 | 226 | 4.32 / 102.07 | 6 | 60 |
7 | 8 | 0.08 | 261 | 15.20 | 310 | 1230 | 5.55 / 103.30 | 6 | -99 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 34 | 15.19 | 472 | 244 | 0.24 / 92.43 | 6 | 16 |
2 | 7 | 2006.76 | 40 | 14.69 | 3100 | 1822 | 2.07 / 94.25 | 16 | 49 |
3 | 13 | 1916.88 | 20 | 14.69 | 2992 | 879 | 2.94 / 95.13 | 6 | 54 |
4 | 13 | 1509.80 | 20 | 14.76 | 2451 | 724 | 3.67 / 95.85 | 6 | 61 |
5 | 13 | 874.08 | 20 | 14.94 | 1566 | 468 | 4.14 / 96.32 | 6 | 66 |
6 | 13 | 108.48 | 20 | 15.23 | 499 | 152 | 4.29 / 96.47 | 6 | 50 |
7 | 8 | 0.12 | 261 | 15.20 | 321 | 1273 | 5.56 / 97.75 | 6 | -99 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 34 | 15.20 | 456 | 236 | 0.24 / 86.82 | 6 | 13 |
2 | 7 | 2008.92 | 40 | 14.70 | 3095 | 1820 | 2.06 / 88.64 | 13 | 48 |
3 | 13 | 1921.12 | 20 | 14.70 | 2978 | 876 | 2.93 / 89.51 | 6 | 54 |
4 | 13 | 1499.28 | 20 | 14.77 | 2408 | 711 | 3.64 / 90.22 | 6 | 59 |
5 | 13 | 871.96 | 20 | 14.95 | 1555 | 465 | 4.11 / 90.69 | 6 | 67 |
6 | 13 | 116.48 | 20 | 15.23 | 510 | 155 | 4.26 / 90.84 | 6 | 52 |
7 | 8 | 0.24 | 261 | 15.20 | 338 | 1341 | 5.60 / 92.19 | 6 | -99 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 34 | 15.20 | 475 | 245 | 0.25 / 81.26 | 6 | 14 |
2 | 7 | 2010.80 | 40 | 14.69 | 3106 | 1825 | 2.07 / 83.08 | 14 | 48 |
3 | 13 | 1915.88 | 20 | 14.71 | 2973 | 875 | 2.95 / 83.96 | 6 | 54 |
4 | 13 | 1496.24 | 20 | 14.77 | 2411 | 712 | 3.66 / 84.67 | 6 | 61 |
5 | 13 | 826.68 | 20 | 14.97 | 1500 | 449 | 4.11 / 85.12 | 6 | 67 |
6 | 13 | 86.48 | 20 | 15.24 | 467 | 142 | 4.25 / 85.26 | 6 | 45 |
7 | 8 | 0.12 | 259 | 15.20 | 335 | 1319 | 5.57 / 86.58 | 6 | -99 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 34 | 15.21 | 467 | 242 | 0.24 / 75.48 | 6 | 13 |
2 | 7 | 2011.72 | 40 | 14.70 | 3111 | 1829 | 2.07 / 77.31 | 13 | 50 |
3 | 13 | 1922.52 | 20 | 14.71 | 2992 | 880 | 2.95 / 78.19 | 6 | 54 |
4 | 13 | 1588.48 | 20 | 14.75 | 2548 | 752 | 3.70 / 78.94 | 6 | 60 |
5 | 13 | 1033.32 | 20 | 14.90 | 1794 | 535 | 4.24 / 79.48 | 6 | 66 |
6 | 13 | 225.76 | 20 | 15.19 | 683 | 207 | 4.44 / 79.68 | 6 | 59 |
7 | 8 | 0.04 | 261 | 15.21 | 335 | 1330 | 5.77 / 81.01 | 6 | 170 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 34 | 15.21 | 448 | 232 | 0.23 / 69.94 | 6 | 12 |
2 | 7 | 2008.68 | 40 | 14.70 | 3098 | 1822 | 2.05 / 71.76 | 12 | 50 |
3 | 13 | 1918.72 | 20 | 14.71 | 2978 | 876 | 2.93 / 72.64 | 6 | 54 |
4 | 13 | 1591.76 | 20 | 14.75 | 2555 | 754 | 3.68 / 73.39 | 6 | 61 |
5 | 13 | 721.96 | 20 | 15.01 | 1358 | 408 | 4.09 / 73.80 | 6 | 65 |
6 | 13 | 93.72 | 20 | 15.24 | 477 | 145 | 4.24 / 73.94 | 6 | 54 |
7 | 8 | 0.16 | 259 | 15.22 | 329 | 1297 | 5.53 / 75.24 | 6 | -99 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 33 | 15.22 | 475 | 239 | 0.24 / 64.41 | 6 | 13 |
2 | 7 | 2003.48 | 40 | 14.72 | 3072 | 1809 | 2.05 / 66.22 | 34 | 50 |
3 | 13 | 1916.36 | 20 | 14.71 | 2994 | 881 | 2.93 / 67.10 | 6 | 54 |
4 | 13 | 1387.44 | 20 | 14.81 | 2283 | 676 | 3.60 / 67.78 | 6 | 64 |
5 | 13 | 954.04 | 20 | 14.93 | 1675 | 500 | 4.10 / 68.28 | 6 | 66 |
6 | 13 | 166.80 | 20 | 15.22 | 575 | 175 | 4.28 / 68.45 | 6 | 58 |
7 | 8 | 0.08 | 259 | 15.22 | 318 | 1254 | 5.53 / 69.71 | 6 | -99 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 33 | 15.21 | 457 | 229 | 0.23 / 58.74 | 6 | 14 |
2 | 7 | 2015.48 | 40 | 14.71 | 3101 | 1825 | 2.05 / 60.57 | 14 | 50 |
3 | 13 | 1940.00 | 20 | 14.73 | 3019 | 889 | 2.94 / 61.46 | 6 | 53 |
4 | 13 | 1499.36 | 20 | 14.79 | 2430 | 719 | 3.66 / 62.17 | 6 | 60 |
5 | 13 | 940.92 | 20 | 14.94 | 1672 | 500 | 4.16 / 62.67 | 6 | 68 |
6 | 13 | 264.32 | 20 | 15.18 | 733 | 223 | 4.38 / 62.90 | 6 | 60 |
7 | 8 | 0.20 | 259 | 15.22 | 324 | 1277 | 5.66 / 64.17 | 6 | -99 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 33 | 15.22 | 456 | 229 | 0.23 / 52.99 | 6 | 15 |
2 | 7 | 2011.84 | 40 | 14.72 | 3098 | 1824 | 2.05 / 54.82 | 15 | 49 |
3 | 13 | 1922.56 | 20 | 14.73 | 2979 | 878 | 2.93 / 55.69 | 6 | 56 |
4 | 13 | 1622.64 | 20 | 14.76 | 2578 | 761 | 3.69 / 56.46 | 6 | 60 |
5 | 13 | 1060.64 | 20 | 14.90 | 1821 | 543 | 4.23 / 57.00 | 6 | 67 |
6 | 13 | 343.64 | 20 | 15.15 | 844 | 256 | 4.49 / 57.25 | 6 | 65 |
7 | 8 | -0.08 | 259 | 15.22 | 319 | 1257 | 5.75 / 58.51 | 6 | -99 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 33 | 15.22 | 469 | 236 | 0.24 / 47.51 | 6 | 16 |
2 | 7 | 2005.00 | 40 | 14.72 | 3090 | 1819 | 2.05 / 49.33 | 16 | 50 |
3 | 13 | 1937.32 | 20 | 14.73 | 2995 | 882 | 2.94 / 50.21 | 6 | 53 |
4 | 13 | 1406.12 | 20 | 14.82 | 2307 | 684 | 3.62 / 50.89 | 6 | 62 |
5 | 13 | 669.64 | 20 | 15.04 | 1300 | 391 | 4.01 / 51.28 | 6 | 67 |
6 | 13 | 243.04 | 20 | 15.20 | 701 | 213 | 4.23 / 51.50 | 6 | 60 |
7 | 8 | 0.16 | 257 | 15.23 | 324 | 1268 | 5.49 / 52.76 | 6 | 148 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 33 | 15.21 | 480 | 241 | 0.24 / 41.96 | 6 | 15 |
2 | 7 | 2009.00 | 40 | 14.72 | 3089 | 1819 | 2.06 / 43.78 | 15 | 50 |
3 | 13 | 1715.84 | 20 | 14.78 | 2714 | 802 | 2.86 / 44.58 | 6 | 57 |
4 | 13 | 1623.52 | 20 | 14.76 | 2570 | 759 | 3.62 / 45.34 | 6 | 59 |
5 | 13 | 825.40 | 20 | 14.99 | 1509 | 452 | 4.07 / 45.79 | 6 | 67 |
6 | 13 | 95.04 | 20 | 15.26 | 480 | 146 | 4.22 / 45.94 | 6 | 50 |
7 | 8 | 0.12 | 259 | 15.23 | 338 | 1333 | 5.55 / 47.27 | 6 | -99 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 33 | 15.22 | 458 | 230 | 0.23 / 36.20 | 6 | 11 |
2 | 7 | 2014.20 | 40 | 14.73 | 3109 | 1832 | 2.06 / 38.04 | 11 | 52 |
3 | 13 | 1929.00 | 20 | 14.74 | 2997 | 884 | 2.95 / 38.92 | 6 | 55 |
4 | 13 | 1516.36 | 20 | 14.79 | 2473 | 732 | 3.68 / 39.65 | 6 | 60 |
5 | 13 | 851.60 | 20 | 14.98 | 1552 | 465 | 4.14 / 40.12 | 6 | 67 |
6 | 13 | 287.28 | 20 | 15.18 | 770 | 234 | 4.38 / 40.35 | 6 | 63 |
7 | 8 | 0.08 | 259 | 15.22 | 347 | 1368 | 5.74 / 41.72 | 6 | 182 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 33 | 15.22 | 471 | 237 | 0.24 / 30.71 | 6 | 16 |
2 | 7 | 2003.68 | 41 | 14.74 | 3066 | 1853 | 2.09 / 32.57 | 16 | 51 |
3 | 13 | 1799.92 | 20 | 14.78 | 2829 | 836 | 2.93 / 33.40 | 6 | 57 |
4 | 13 | 1277.64 | 20 | 14.87 | 2129 | 633 | 3.56 / 34.04 | 6 | 64 |
5 | 13 | 743.64 | 20 | 15.02 | 1400 | 421 | 3.98 / 34.46 | 6 | 66 |
6 | 13 | 96.40 | 20 | 15.26 | 490 | 150 | 4.13 / 34.61 | 6 | 53 |
7 | 8 | 0.12 | 259 | 15.22 | 347 | 1368 | 5.50 / 35.97 | 6 | -99 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 31 | 15.23 | 469 | 221 | 0.22 / 25.02 | 6 | 13 |
2 | 10 | 1016.32 | 3 | 15.16 | 1750 | 80 | 0.30 / 25.10 | 6 | 49 |
3 | 7 | 2007.64 | 40 | 14.74 | 3090 | 1822 | 2.12 / 26.92 | 49 | 53 |
4 | 13 | 1911.64 | 20 | 14.76 | 2967 | 876 | 3.00 / 27.79 | 6 | 56 |
5 | 13 | 1602.12 | 20 | 14.78 | 2547 | 753 | 3.75 / 28.55 | 6 | 62 |
6 | 13 | 791.60 | 20 | 15.01 | 1456 | 437 | 4.19 / 28.98 | 6 | 68 |
7 | 13 | 67.12 | 20 | 15.27 | 437 | 133 | 4.32 / 29.12 | 6 | 52 |
8 | 8 | 0.12 | 259 | 15.23 | 345 | 1361 | 5.68 / 30.48 | 6 | 224 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 31 | 15.22 | 487 | 230 | 0.23 / 19.25 | 6 | 17 |
2 | 10 | 1021.00 | 3 | 15.16 | 1762 | 80 | 0.31 / 19.33 | 6 | 49 |
3 | 3 | 950.12 | -1 | 15.56 | 2 | 0 | 0.08 / 19.33 | 6 | 49 |
4 | 7 | 2009.88 | 40 | 14.75 | 3094 | 1825 | 2.14 / 21.15 | 49 | 52 |
5 | 13 | 1923.00 | 20 | 14.75 | 2981 | 879 | 3.01 / 22.03 | 6 | 56 |
6 | 13 | 1600.64 | 20 | 14.78 | 2553 | 755 | 3.77 / 22.79 | 6 | 61 |
7 | 13 | 920.92 | 20 | 14.97 | 1638 | 490 | 4.26 / 23.28 | 6 | 66 |
8 | 13 | 125.80 | 20 | 15.25 | 528 | 161 | 4.42 / 23.44 | 6 | 58 |
9 | 8 | 0.16 | 259 | 15.23 | 344 | 1357 | 5.78 / 24.79 | 6 | 135 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 31 | 15.22 | 483 | 228 | 0.23 / 14.27 | 6 | 16 |
2 | 10 | 1012.92 | 3 | 15.17 | 1746 | 79 | 0.31 / 14.35 | 6 | 50 |
3 | 3 | 942.64 | -1 | 15.56 | 3 | 0 | 0.08 / 14.35 | 6 | 50 |
4 | 7 | 1510.56 | 41 | 14.95 | 2440 | 1496 | 1.80 / 15.84 | 50 | 55 |
5 | 13 | 1456.56 | 20 | 14.94 | 2360 | 705 | 2.51 / 16.55 | 6 | 57 |
6 | 13 | 1156.60 | 20 | 14.98 | 1929 | 578 | 3.09 / 17.12 | 6 | 62 |
7 | 13 | 723.00 | 20 | 15.07 | 1346 | 406 | 3.49 / 17.53 | 6 | 67 |
8 | 13 | 135.80 | 20 | 15.26 | 543 | 166 | 3.66 / 17.70 | 6 | 57 |
9 | 8 | 0.00 | 255 | 15.24 | 340 | 1321 | 4.98 / 19.02 | 6 | -99 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 31 | 15.21 | 466 | 220 | 0.22 / 9.50 | 6 | 13 |
2 | 7 | 1507.08 | 40 | 14.97 | 2387 | 1429 | 1.65 / 10.93 | 13 | 51 |
3 | 13 | 1447.96 | 20 | 14.95 | 2347 | 702 | 2.35 / 11.63 | 6 | 58 |
4 | 13 | 1354.08 | 20 | 14.93 | 2188 | 653 | 3.00 / 12.28 | 6 | 58 |
5 | 13 | 456.28 | 20 | 15.17 | 995 | 302 | 3.31 / 12.58 | 6 | 65 |
6 | 13 | 141.76 | 20 | 15.26 | 552 | 168 | 3.47 / 12.75 | 6 | 55 |
7 | 8 | 0.04 | 255 | 15.24 | 331 | 1286 | 4.76 / 14.04 | 6 | 152 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 31 | 15.24 | 445 | 210 | 0.21 / 4.59 | 6 | 14 |
2 | 7 | 1519.00 | 40 | 14.96 | 2396 | 1434 | 1.64 / 6.03 | 51 | 52 |
3 | 13 | 1444.88 | 20 | 14.96 | 2307 | 690 | 2.33 / 6.72 | 6 | 57 |
4 | 13 | 1350.04 | 20 | 14.93 | 2178 | 650 | 2.98 / 7.37 | 6 | 59 |
5 | 13 | 1005.16 | 20 | 14.99 | 1694 | 508 | 3.49 / 7.87 | 6 | 63 |
6 | 13 | 44.04 | 20 | 15.29 | 392 | 120 | 3.61 / 7.99 | 6 | 50 |
7 | 8 | 0.12 | 255 | 15.24 | 330 | 1282 | 4.89 / 9.28 | 6 | 143 |
Average= | 3.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 31 | 15.43 | 402 | 192 | 0.19 / 1.72 | 6 | 13 |
2 | 7 | 1001.20 | 40 | 15.10 | 1689 | 1020 | 1.21 / 2.74 | 13 | 59 |
3 | 13 | 491.96 | 20 | 15.21 | 1024 | 312 | 1.52 / 3.05 | 6 | 64 |
4 | 13 | 70.92 | 20 | 15.32 | 432 | 132 | 1.66 / 3.18 | 6 | 51 |
5 | 8 | 0.08 | 253 | 15.28 | 310 | 1198 | 2.85 / 4.38 | 6 | 145 |
Average= | 2.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 55.04 | 30 | 15.58 | 340 | 159 | 0.16 / 0.16 | 6 | 21 |
2 | 7 | 64.32 | 40 | 15.56 | 353 | 220 | 0.38 / 0.38 | 21 | 25 |
3 | 13 | 39.84 | 20 | 15.56 | 323 | 101 | 0.48 / 0.48 | 6 | 28 |
4 | 8 | 0.04 | 263 | 15.51 | 257 | 1048 | 1.53 / 1.53 | 6 | -99 |
Average= | 1.53 (KJ/cycle) |