SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 37 | 14.83 | 440 | 241 | 0.24 / 793.91 | 6 | 12 |
2 | 7 | 2004.20 | 40 | 14.67 | 3037 | 1782 | 2.02 / 795.69 | 8 | 58 |
3 | 13 | 1914.64 | 20 | 14.64 | 2926 | 857 | 2.88 / 796.54 | 5 | 61 |
4 | 13 | 1503.96 | 20 | 14.60 | 2409 | 703 | 3.58 / 797.25 | 5 | 69 |
5 | 13 | 957.32 | 20 | 14.63 | 1674 | 490 | 4.07 / 797.74 | 5 | 75 |
6 | 13 | 198.24 | 20 | 14.80 | 621 | 184 | 4.26 / 797.92 | 6 | 79 |
7 | 13 | 53.20 | 20 | 14.85 | 386 | 115 | 4.37 / 798.04 | 6 | 65 |
8 | 8 | 0.08 | 244 | 14.81 | 304 | 1099 | 5.47 / 799.13 | 6 | 131 |
Average= | 8.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 37 | 14.81 | 428 | 235 | 0.23 / 788.45 | 6 | 13 |
2 | 7 | 2006.04 | 40 | 14.68 | 3031 | 1780 | 2.01 / 790.23 | 9 | 56 |
3 | 13 | 1924.04 | 20 | 14.64 | 2940 | 861 | 2.88 / 791.09 | 5 | 60 |
4 | 13 | 1412.60 | 20 | 14.62 | 2272 | 664 | 3.54 / 791.76 | 5 | 69 |
5 | 13 | 988.84 | 20 | 14.64 | 1695 | 496 | 4.04 / 792.25 | 5 | 75 |
6 | 13 | 227.04 | 20 | 14.80 | 651 | 193 | 4.23 / 792.44 | 6 | 77 |
7 | 13 | 54.04 | 20 | 14.85 | 398 | 118 | 4.35 / 792.56 | 6 | 77 |
8 | 8 | -0.08 | 240 | 14.81 | 310 | 1102 | 5.45 / 793.66 | 6 | 134 |
Average= | 8.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 37 | 14.84 | 419 | 230 | 0.23 / 783.01 | 6 | 10 |
2 | 7 | 2003.84 | 40 | 14.67 | 3024 | 1774 | 2.00 / 784.79 | 10 | 56 |
3 | 13 | 1916.12 | 20 | 14.63 | 2933 | 858 | 2.86 / 785.65 | 5 | 61 |
4 | 13 | 1406.60 | 20 | 14.61 | 2278 | 666 | 3.53 / 786.31 | 5 | 70 |
5 | 13 | 885.60 | 20 | 14.65 | 1574 | 461 | 3.99 / 786.77 | 5 | 77 |
6 | 13 | 246.28 | 20 | 14.78 | 693 | 205 | 4.19 / 786.98 | 6 | 80 |
7 | 13 | 62.04 | 20 | 14.83 | 415 | 123 | 4.32 / 787.10 | 6 | 78 |
8 | 8 | 0.16 | 244 | 14.80 | 309 | 1116 | 5.43 / 788.22 | 6 | 135 |
Average= | 8.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 37 | 14.84 | 426 | 234 | 0.23 / 777.59 | 6 | 12 |
2 | 7 | 2007.28 | 40 | 14.68 | 3019 | 1773 | 2.01 / 779.37 | 12 | 56 |
3 | 13 | 1926.80 | 20 | 14.64 | 2924 | 856 | 2.86 / 780.22 | 5 | 59 |
4 | 13 | 1610.84 | 20 | 14.60 | 2526 | 738 | 3.60 / 780.96 | 5 | 66 |
5 | 13 | 965.60 | 20 | 14.64 | 1660 | 486 | 4.09 / 781.45 | 5 | 75 |
6 | 13 | 113.72 | 20 | 14.84 | 503 | 149 | 4.24 / 781.60 | 6 | 78 |
7 | 13 | 34.92 | 20 | 14.86 | 363 | 108 | 4.34 / 781.70 | 6 | 73 |
8 | 8 | 0.16 | 240 | 14.82 | 303 | 1078 | 5.42 / 782.78 | 6 | 133 |
Average= | 8.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 37 | 14.82 | 432 | 237 | 0.24 / 772.26 | 6 | 12 |
2 | 7 | 2006.12 | 40 | 14.67 | 3041 | 1784 | 2.02 / 774.05 | 12 | 56 |
3 | 13 | 1920.72 | 20 | 14.64 | 2942 | 861 | 2.88 / 774.91 | 5 | 59 |
4 | 13 | 1503.04 | 20 | 14.61 | 2384 | 697 | 3.58 / 775.60 | 5 | 67 |
5 | 13 | 844.28 | 20 | 14.67 | 1508 | 442 | 4.02 / 776.05 | 6 | 76 |
6 | 13 | 109.80 | 20 | 14.84 | 488 | 145 | 4.17 / 776.19 | 6 | 80 |
7 | 13 | 35.32 | 20 | 14.86 | 362 | 108 | 4.27 / 776.30 | 6 | 74 |
8 | 8 | 0.12 | 238 | 14.82 | 301 | 1062 | 5.34 / 777.36 | 6 | 134 |
Average= | 8.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 37 | 14.83 | 417 | 229 | 0.23 / 766.80 | 6 | 11 |
2 | 7 | 2014.88 | 40 | 14.67 | 3050 | 1790 | 2.02 / 768.59 | 11 | 57 |
3 | 13 | 1928.08 | 20 | 14.63 | 2941 | 861 | 2.88 / 769.45 | 5 | 60 |
4 | 13 | 1510.16 | 20 | 14.61 | 2396 | 700 | 3.58 / 770.15 | 5 | 68 |
5 | 13 | 871.20 | 20 | 14.66 | 1541 | 452 | 4.03 / 770.60 | 5 | 76 |
6 | 13 | 222.88 | 20 | 14.79 | 660 | 195 | 4.23 / 770.80 | 6 | 81 |
7 | 13 | 54.72 | 20 | 14.84 | 405 | 120 | 4.35 / 770.92 | 6 | 79 |
8 | 8 | 0.08 | 238 | 14.80 | 314 | 1106 | 5.45 / 772.03 | 6 | 130 |
Average= | 8.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 37 | 14.83 | 432 | 237 | 0.24 / 761.36 | 6 | 11 |
2 | 7 | 2004.28 | 41 | 14.67 | 3026 | 1820 | 2.06 / 763.18 | 11 | 56 |
3 | 13 | 1917.64 | 20 | 14.63 | 2927 | 856 | 2.91 / 764.04 | 5 | 60 |
4 | 13 | 1486.76 | 20 | 14.61 | 2373 | 693 | 3.61 / 764.73 | 5 | 68 |
5 | 13 | 841.76 | 20 | 14.66 | 1508 | 442 | 4.05 / 765.17 | 6 | 78 |
6 | 13 | 302.40 | 20 | 14.78 | 769 | 227 | 4.28 / 765.40 | 6 | 81 |
7 | 13 | 44.56 | 20 | 14.85 | 379 | 113 | 4.39 / 765.51 | 6 | 76 |
8 | 8 | 0.08 | 238 | 14.81 | 301 | 1061 | 5.45 / 766.57 | 6 | 130 |
Average= | 9.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 37 | 14.82 | 436 | 239 | 0.24 / 756.02 | 6 | 11 |
2 | 7 | 2006.16 | 40 | 14.67 | 3022 | 1773 | 2.01 / 757.79 | 8 | 56 |
3 | 13 | 1917.88 | 20 | 14.63 | 2937 | 859 | 2.87 / 758.65 | 5 | 60 |
4 | 13 | 1385.64 | 20 | 14.62 | 2239 | 655 | 3.53 / 759.30 | 6 | 71 |
5 | 13 | 859.00 | 20 | 14.65 | 1524 | 447 | 3.97 / 759.75 | 5 | 77 |
6 | 13 | 206.48 | 20 | 14.80 | 625 | 185 | 4.16 / 759.93 | 6 | 79 |
7 | 13 | 52.72 | 20 | 14.85 | 381 | 113 | 4.27 / 760.05 | 6 | 70 |
8 | 8 | 0.12 | 242 | 14.81 | 300 | 1075 | 5.35 / 761.12 | 6 | 131 |
Average= | 9.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 37 | 14.85 | 424 | 233 | 0.23 / 750.61 | 6 | 9 |
2 | 7 | 2004.52 | 40 | 14.67 | 3022 | 1773 | 2.01 / 752.39 | 9 | 57 |
3 | 13 | 1917.32 | 20 | 14.63 | 2929 | 857 | 2.86 / 753.24 | 5 | 60 |
4 | 13 | 1498.72 | 20 | 14.61 | 2388 | 698 | 3.56 / 753.94 | 5 | 68 |
5 | 13 | 840.08 | 20 | 14.66 | 1506 | 442 | 4.00 / 754.38 | 5 | 77 |
6 | 13 | 195.96 | 20 | 14.81 | 610 | 181 | 4.18 / 754.56 | 6 | 77 |
7 | 13 | 48.88 | 20 | 14.85 | 379 | 113 | 4.30 / 754.68 | 6 | 68 |
8 | 8 | 0.08 | 246 | 14.81 | 302 | 1100 | 5.40 / 755.78 | 6 | 136 |
Average= | 9.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 37 | 14.83 | 424 | 233 | 0.23 / 745.24 | 6 | 10 |
2 | 7 | 2007.84 | 40 | 14.68 | 3037 | 1783 | 2.02 / 747.02 | 10 | 56 |
3 | 13 | 1919.08 | 20 | 14.63 | 2936 | 859 | 2.88 / 747.88 | 5 | 59 |
4 | 13 | 1497.76 | 20 | 14.61 | 2389 | 698 | 3.57 / 748.58 | 5 | 68 |
5 | 13 | 857.64 | 20 | 14.66 | 1536 | 450 | 4.02 / 749.03 | 5 | 76 |
6 | 13 | 113.08 | 20 | 14.84 | 492 | 146 | 4.17 / 749.17 | 6 | 77 |
7 | 13 | 60.56 | 20 | 14.85 | 402 | 119 | 4.29 / 749.29 | 6 | 75 |
8 | 13 | 19.24 | 20 | 14.86 | 330 | 98 | 4.39 / 749.39 | 6 | 68 |
9 | 8 | 0.00 | 225 | 14.82 | 297 | 990 | 5.38 / 750.38 | 6 | 134 |
Average= | 9.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 37 | 14.83 | 430 | 236 | 0.24 / 739.78 | 6 | 10 |
2 | 7 | 2003.76 | 40 | 14.68 | 3024 | 1776 | 2.01 / 741.56 | 10 | 55 |
3 | 13 | 1915.84 | 20 | 14.64 | 2942 | 861 | 2.87 / 742.42 | 5 | 60 |
4 | 13 | 1411.16 | 20 | 14.62 | 2274 | 665 | 3.54 / 743.08 | 5 | 69 |
5 | 13 | 985.08 | 20 | 14.63 | 1713 | 501 | 4.04 / 743.58 | 5 | 75 |
6 | 13 | 326.40 | 20 | 14.76 | 806 | 238 | 4.28 / 743.82 | 6 | 81 |
7 | 13 | 104.04 | 20 | 14.82 | 471 | 140 | 4.42 / 743.96 | 6 | 77 |
8 | 8 | 0.08 | 240 | 14.81 | 293 | 1041 | 5.46 / 745.00 | 6 | 140 |
Average= | 9.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 37 | 14.84 | 439 | 241 | 0.24 / 734.35 | 6 | 10 |
2 | 7 | 2015.92 | 41 | 14.67 | 3034 | 1825 | 2.07 / 736.18 | 10 | 56 |
3 | 13 | 1936.00 | 20 | 14.63 | 2959 | 866 | 2.93 / 737.04 | 5 | 60 |
4 | 13 | 1411.28 | 20 | 14.61 | 2275 | 665 | 3.60 / 737.71 | 5 | 70 |
5 | 13 | 870.76 | 20 | 14.65 | 1542 | 452 | 4.05 / 738.16 | 5 | 76 |
6 | 13 | 231.32 | 20 | 14.79 | 664 | 196 | 4.24 / 738.36 | 6 | 78 |
7 | 13 | 70.40 | 20 | 14.84 | 398 | 118 | 4.36 / 738.48 | 6 | 68 |
8 | 8 | 0.12 | 248 | 14.81 | 291 | 1069 | 5.43 / 739.54 | 6 | 140 |
Average= | 9.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 36 | 14.82 | 432 | 230 | 0.23 / 728.81 | 6 | 11 |
2 | 3 | 1021.68 | 1 | 15.02 | 1812 | 27 | 0.26 / 728.84 | 5 | 19 |
3 | 7 | 2007.48 | 40 | 14.67 | 3051 | 1790 | 2.05 / 730.63 | 19 | 57 |
4 | 13 | 1929.84 | 20 | 14.63 | 2978 | 871 | 2.92 / 731.50 | 5 | 61 |
5 | 13 | 1531.52 | 20 | 14.60 | 2438 | 712 | 3.63 / 732.21 | 5 | 68 |
6 | 13 | 897.28 | 20 | 14.64 | 1596 | 467 | 4.10 / 732.68 | 5 | 77 |
7 | 13 | 242.64 | 20 | 14.79 | 689 | 204 | 4.30 / 732.88 | 6 | 79 |
8 | 13 | 80.32 | 20 | 14.84 | 427 | 127 | 4.43 / 733.01 | 6 | 64 |
9 | 8 | -0.04 | 248 | 14.82 | 301 | 1106 | 5.54 / 734.11 | 6 | 132 |
Average= | 9.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 36 | 14.84 | 425 | 227 | 0.23 / 723.42 | 6 | 9 |
2 | 7 | 2006.04 | 40 | 14.68 | 3023 | 1775 | 2.00 / 725.19 | 9 | 56 |
3 | 13 | 1916.96 | 20 | 14.64 | 2940 | 861 | 2.86 / 726.06 | 5 | 60 |
4 | 13 | 1397.28 | 20 | 14.62 | 2255 | 659 | 3.52 / 726.72 | 5 | 70 |
5 | 13 | 863.52 | 20 | 14.66 | 1535 | 450 | 3.97 / 727.17 | 5 | 76 |
6 | 13 | 207.96 | 20 | 14.80 | 631 | 187 | 4.16 / 727.35 | 6 | 78 |
7 | 13 | 113.60 | 20 | 14.82 | 485 | 144 | 4.30 / 727.50 | 6 | 74 |
8 | 8 | 0.00 | 246 | 14.81 | 297 | 1082 | 5.38 / 728.58 | 6 | 132 |
Average= | 9.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 35 | 14.81 | 426 | 221 | 0.22 / 718.09 | 6 | 9 |
2 | 3 | 1028.76 | 1 | 15.02 | 1794 | 27 | 0.25 / 718.12 | 6 | 26 |
3 | 7 | 2014.44 | 40 | 14.67 | 3042 | 1785 | 2.03 / 719.90 | 26 | 57 |
4 | 13 | 1930.52 | 20 | 14.63 | 2956 | 865 | 2.90 / 720.77 | 5 | 61 |
5 | 13 | 1326.08 | 20 | 14.63 | 2157 | 631 | 3.53 / 721.40 | 5 | 70 |
6 | 13 | 808.76 | 20 | 14.67 | 1459 | 428 | 3.96 / 721.82 | 5 | 77 |
7 | 13 | 179.44 | 20 | 14.81 | 588 | 174 | 4.13 / 722.00 | 6 | 76 |
8 | 13 | 95.04 | 20 | 14.84 | 443 | 131 | 4.26 / 722.13 | 6 | 67 |
9 | 8 | 0.16 | 249 | 14.82 | 288 | 1063 | 5.33 / 723.19 | 6 | 137 |
Average= | 9.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 36 | 14.83 | 424 | 226 | 0.23 / 712.58 | 6 | 8 |
2 | 7 | 2006.24 | 40 | 14.68 | 3033 | 1781 | 2.01 / 714.36 | 8 | 57 |
3 | 13 | 1919.36 | 20 | 14.64 | 2945 | 862 | 2.87 / 715.23 | 5 | 60 |
4 | 13 | 1408.68 | 20 | 14.62 | 2279 | 666 | 3.54 / 715.89 | 5 | 70 |
5 | 13 | 1073.92 | 20 | 14.62 | 1834 | 536 | 4.07 / 716.43 | 5 | 74 |
6 | 13 | 279.04 | 20 | 14.77 | 745 | 220 | 4.29 / 716.65 | 6 | 79 |
7 | 13 | 83.80 | 20 | 14.82 | 446 | 132 | 4.42 / 716.78 | 6 | 75 |
8 | 8 | 5.12 | 244 | 14.79 | 301 | 1086 | 5.51 / 717.87 | 6 | 129 |
Average= | 9.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 36 | 14.81 | 413 | 220 | 0.22 / 707.06 | 6 | 10 |
2 | 7 | 2013.48 | 40 | 14.67 | 3056 | 1793 | 2.01 / 708.85 | 10 | 57 |
3 | 13 | 1922.04 | 20 | 14.64 | 2948 | 863 | 2.88 / 709.71 | 5 | 62 |
4 | 13 | 1501.48 | 20 | 14.61 | 2391 | 699 | 3.58 / 710.41 | 5 | 69 |
5 | 13 | 963.84 | 20 | 14.63 | 1700 | 497 | 4.07 / 710.91 | 6 | 76 |
6 | 13 | 310.40 | 20 | 14.77 | 790 | 233 | 4.31 / 711.14 | 6 | 82 |
7 | 13 | 54.36 | 20 | 14.84 | 384 | 114 | 4.42 / 711.25 | 6 | 69 |
8 | 13 | 19.76 | 20 | 14.85 | 329 | 98 | 4.52 / 711.35 | 6 | 64 |
9 | 8 | 0.08 | 229 | 14.81 | 296 | 1004 | 5.52 / 712.36 | 6 | 134 |
Average= | 9.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 36 | 14.83 | 436 | 233 | 0.23 / 701.54 | 6 | 9 |
2 | 7 | 2004.68 | 40 | 14.67 | 3048 | 1789 | 2.02 / 703.32 | 9 | 57 |
3 | 13 | 1919.36 | 20 | 14.64 | 2949 | 863 | 2.88 / 704.19 | 5 | 62 |
4 | 13 | 1503.12 | 20 | 14.61 | 2419 | 707 | 3.59 / 704.89 | 5 | 70 |
5 | 13 | 941.60 | 20 | 14.64 | 1648 | 483 | 4.07 / 705.38 | 5 | 77 |
6 | 13 | 278.12 | 20 | 14.77 | 739 | 218 | 4.29 / 705.60 | 6 | 78 |
7 | 13 | 87.80 | 20 | 14.82 | 453 | 134 | 4.43 / 705.73 | 6 | 72 |
8 | 13 | 11.16 | 20 | 14.85 | 316 | 94 | 4.52 / 705.82 | 6 | 61 |
9 | 8 | 9.04 | 227 | 14.80 | 301 | 1011 | 5.53 / 706.83 | 6 | 132 |
Average= | 9.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 36 | 14.83 | 437 | 233 | 0.23 / 696.09 | 6 | 9 |
2 | 7 | 2007.84 | 40 | 14.67 | 3038 | 1783 | 2.02 / 697.87 | 9 | 58 |
3 | 13 | 1925.92 | 20 | 14.63 | 2953 | 864 | 2.88 / 698.73 | 5 | 61 |
4 | 13 | 1605.84 | 20 | 14.60 | 2539 | 741 | 3.62 / 699.47 | 5 | 68 |
5 | 13 | 834.20 | 20 | 14.66 | 1504 | 441 | 4.06 / 699.92 | 5 | 77 |
6 | 13 | 114.20 | 20 | 14.83 | 499 | 148 | 4.21 / 700.06 | 6 | 73 |
7 | 13 | 70.72 | 20 | 14.84 | 417 | 124 | 4.33 / 700.19 | 6 | 65 |
8 | 13 | 17.12 | 20 | 14.85 | 331 | 98 | 4.43 / 700.29 | 6 | 60 |
9 | 8 | 0.00 | 229 | 14.81 | 300 | 1017 | 5.45 / 701.30 | 6 | 132 |
Average= | 9.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 37 | 14.83 | 436 | 239 | 0.24 / 690.71 | 6 | 11 |
2 | 7 | 2010.52 | 40 | 14.68 | 3047 | 1789 | 2.03 / 692.50 | 11 | 58 |
3 | 13 | 1921.28 | 20 | 14.64 | 2951 | 864 | 2.89 / 693.37 | 5 | 62 |
4 | 13 | 1397.72 | 20 | 14.63 | 2259 | 661 | 3.55 / 694.03 | 5 | 71 |
5 | 13 | 864.76 | 20 | 14.66 | 1550 | 454 | 4.01 / 694.48 | 5 | 78 |
6 | 13 | 128.28 | 20 | 14.83 | 518 | 154 | 4.16 / 694.64 | 6 | 75 |
7 | 13 | 74.76 | 20 | 14.84 | 423 | 126 | 4.29 / 694.76 | 6 | 70 |
8 | 13 | 14.96 | 20 | 14.85 | 325 | 97 | 4.38 / 694.86 | 6 | 65 |
9 | 8 | 0.16 | 227 | 14.81 | 296 | 995 | 5.38 / 695.85 | 6 | 131 |
Average= | 9.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 37 | 14.82 | 428 | 235 | 0.23 / 685.30 | 6 | 11 |
2 | 7 | 2007.00 | 40 | 14.68 | 3043 | 1787 | 2.02 / 687.09 | 11 | 58 |
3 | 13 | 1930.44 | 20 | 14.63 | 2966 | 868 | 2.89 / 687.96 | 5 | 61 |
4 | 13 | 1508.56 | 20 | 14.61 | 2397 | 700 | 3.59 / 688.66 | 5 | 69 |
5 | 13 | 851.40 | 20 | 14.66 | 1517 | 445 | 4.03 / 689.10 | 5 | 76 |
6 | 13 | 118.60 | 20 | 14.84 | 498 | 148 | 4.18 / 689.25 | 6 | 74 |
7 | 13 | 68.72 | 20 | 14.85 | 410 | 122 | 4.30 / 689.37 | 6 | 69 |
8 | 13 | 14.44 | 20 | 14.86 | 324 | 96 | 4.40 / 689.47 | 6 | 63 |
9 | 8 | 0.16 | 227 | 14.81 | 299 | 1005 | 5.41 / 690.47 | 6 | 130 |
Average= | 9.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 37 | 14.83 | 432 | 237 | 0.24 / 679.91 | 6 | 11 |
2 | 7 | 2009.88 | 41 | 14.68 | 3031 | 1824 | 2.06 / 681.73 | 11 | 57 |
3 | 13 | 1925.08 | 20 | 14.65 | 2945 | 863 | 2.92 / 682.60 | 5 | 60 |
4 | 13 | 1396.08 | 20 | 14.64 | 2239 | 656 | 3.58 / 683.25 | 5 | 71 |
5 | 13 | 856.08 | 20 | 14.67 | 1517 | 445 | 4.02 / 683.70 | 6 | 77 |
6 | 13 | 189.04 | 20 | 14.81 | 604 | 179 | 4.20 / 683.87 | 6 | 77 |
7 | 13 | 50.88 | 20 | 14.84 | 377 | 112 | 4.32 / 683.99 | 6 | 67 |
8 | 8 | 0.00 | 246 | 14.81 | 297 | 1082 | 5.40 / 685.07 | 6 | 139 |
Average= | 9.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 37 | 14.81 | 442 | 242 | 0.24 / 674.48 | 6 | 10 |
2 | 7 | 2007.56 | 40 | 14.68 | 3047 | 1789 | 2.03 / 676.26 | 10 | 56 |
3 | 13 | 1934.60 | 20 | 14.64 | 2960 | 867 | 2.90 / 677.13 | 5 | 60 |
4 | 13 | 1531.56 | 20 | 14.61 | 2444 | 714 | 3.61 / 677.85 | 5 | 69 |
5 | 13 | 871.28 | 20 | 14.67 | 1540 | 452 | 4.06 / 678.30 | 5 | 76 |
6 | 13 | 136.92 | 20 | 14.84 | 527 | 156 | 4.22 / 678.45 | 6 | 76 |
7 | 13 | 75.48 | 20 | 14.85 | 421 | 125 | 4.35 / 678.58 | 6 | 71 |
8 | 8 | 0.08 | 249 | 14.82 | 296 | 1092 | 5.44 / 679.67 | 6 | 134 |
Average= | 9.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 37 | 14.82 | 425 | 233 | 0.23 / 668.94 | 6 | 10 |
2 | 7 | 2004.40 | 40 | 14.68 | 3034 | 1782 | 2.01 / 670.72 | 10 | 56 |
3 | 13 | 1910.92 | 20 | 14.65 | 2935 | 860 | 2.87 / 671.58 | 5 | 60 |
4 | 13 | 1492.44 | 20 | 14.63 | 2392 | 700 | 3.57 / 672.28 | 5 | 69 |
5 | 13 | 1150.80 | 20 | 14.62 | 1931 | 565 | 4.14 / 672.85 | 5 | 74 |
6 | 13 | 234.20 | 20 | 14.79 | 686 | 203 | 4.34 / 673.05 | 6 | 78 |
7 | 13 | 70.60 | 20 | 14.84 | 416 | 123 | 4.47 / 673.17 | 6 | 69 |
8 | 8 | 0.08 | 242 | 14.81 | 296 | 1061 | 5.53 / 674.23 | 6 | 138 |
Average= | 9.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 37 | 14.84 | 428 | 235 | 0.24 / 663.55 | 6 | 10 |
2 | 7 | 2005.72 | 40 | 14.68 | 3036 | 1783 | 2.02 / 665.34 | 10 | 55 |
3 | 13 | 1917.68 | 20 | 14.65 | 2937 | 861 | 2.88 / 666.20 | 5 | 60 |
4 | 13 | 1508.92 | 20 | 14.62 | 2417 | 707 | 3.59 / 666.90 | 5 | 68 |
5 | 13 | 847.20 | 20 | 14.67 | 1521 | 446 | 4.03 / 667.35 | 5 | 76 |
6 | 13 | 117.60 | 20 | 14.84 | 500 | 148 | 4.18 / 667.50 | 6 | 72 |
7 | 13 | 64.40 | 20 | 14.84 | 406 | 121 | 4.30 / 667.62 | 6 | 68 |
8 | 8 | 0.08 | 246 | 14.81 | 299 | 1089 | 5.39 / 668.71 | 6 | 141 |
Average= | 9.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 37 | 14.83 | 433 | 238 | 0.24 / 658.26 | 6 | 11 |
2 | 7 | 2004.40 | 40 | 14.69 | 3016 | 1772 | 2.01 / 660.03 | 11 | 56 |
3 | 13 | 1915.56 | 20 | 14.65 | 2939 | 861 | 2.87 / 660.89 | 5 | 60 |
4 | 13 | 1474.32 | 20 | 14.63 | 2348 | 687 | 3.56 / 661.58 | 5 | 69 |
5 | 13 | 825.96 | 20 | 14.68 | 1482 | 435 | 3.99 / 662.01 | 5 | 75 |
6 | 13 | 104.92 | 20 | 14.85 | 473 | 140 | 4.13 / 662.15 | 6 | 73 |
7 | 13 | 62.44 | 20 | 14.86 | 395 | 117 | 4.25 / 662.27 | 6 | 68 |
8 | 8 | 0.12 | 242 | 14.83 | 292 | 1048 | 5.30 / 663.32 | 6 | 132 |
Average= | 10.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 37 | 14.83 | 430 | 236 | 0.24 / 652.91 | 6 | 12 |
2 | 7 | 2003.36 | 40 | 14.69 | 3012 | 1770 | 2.01 / 654.68 | 12 | 58 |
3 | 13 | 1907.12 | 20 | 14.66 | 2910 | 853 | 2.86 / 655.53 | 5 | 61 |
4 | 13 | 1391.80 | 20 | 14.64 | 2244 | 657 | 3.52 / 656.19 | 5 | 71 |
5 | 13 | 1075.48 | 20 | 14.64 | 1811 | 530 | 4.05 / 656.72 | 5 | 76 |
6 | 13 | 95.60 | 20 | 14.85 | 453 | 135 | 4.18 / 656.85 | 6 | 73 |
7 | 13 | 56.00 | 20 | 14.85 | 385 | 114 | 4.30 / 656.97 | 6 | 70 |
8 | 8 | 0.00 | 242 | 14.82 | 293 | 1051 | 5.35 / 658.02 | 6 | 132 |
Average= | 10.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 37 | 14.83 | 419 | 230 | 0.23 / 647.55 | 6 | 11 |
2 | 7 | 2006.20 | 40 | 14.69 | 3028 | 1779 | 2.01 / 649.33 | 11 | 57 |
3 | 13 | 1928.08 | 20 | 14.65 | 2950 | 864 | 2.87 / 650.20 | 5 | 61 |
4 | 13 | 1398.80 | 20 | 14.64 | 2256 | 661 | 3.53 / 650.86 | 5 | 70 |
5 | 13 | 886.24 | 20 | 14.67 | 1559 | 457 | 3.99 / 651.31 | 6 | 76 |
6 | 13 | 115.08 | 20 | 14.84 | 501 | 149 | 4.14 / 651.46 | 6 | 77 |
7 | 13 | 62.08 | 20 | 14.85 | 411 | 122 | 4.26 / 651.59 | 6 | 75 |
8 | 8 | 0.08 | 242 | 14.82 | 303 | 1087 | 5.35 / 652.67 | 6 | 132 |
Average= | 10.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 37 | 14.82 | 426 | 234 | 0.23 / 642.13 | 6 | 11 |
2 | 7 | 2012.56 | 40 | 14.69 | 3022 | 1776 | 2.01 / 643.91 | 11 | 56 |
3 | 13 | 1920.12 | 20 | 14.66 | 2935 | 861 | 2.87 / 644.77 | 5 | 61 |
4 | 13 | 1606.56 | 20 | 14.62 | 2533 | 741 | 3.61 / 645.51 | 5 | 68 |
5 | 13 | 844.40 | 20 | 14.68 | 1507 | 442 | 4.05 / 645.95 | 5 | 77 |
6 | 13 | 210.80 | 20 | 14.82 | 642 | 190 | 4.24 / 646.14 | 6 | 77 |
7 | 13 | 56.48 | 20 | 14.86 | 401 | 119 | 4.36 / 646.26 | 6 | 74 |
8 | 8 | 0.08 | 240 | 14.82 | 299 | 1063 | 5.43 / 647.32 | 6 | 130 |
Average= | 10.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 37 | 14.83 | 434 | 238 | 0.24 / 636.68 | 6 | 12 |
2 | 7 | 2013.28 | 40 | 14.70 | 3035 | 1785 | 2.02 / 638.47 | 12 | 55 |
3 | 13 | 1926.32 | 20 | 14.66 | 2939 | 862 | 2.88 / 639.33 | 5 | 60 |
4 | 13 | 1481.36 | 20 | 14.64 | 2373 | 695 | 3.58 / 640.02 | 5 | 70 |
5 | 13 | 929.52 | 20 | 14.67 | 1611 | 473 | 4.05 / 640.49 | 5 | 75 |
6 | 13 | 277.04 | 20 | 14.80 | 723 | 214 | 4.27 / 640.71 | 6 | 76 |
7 | 13 | 40.12 | 20 | 14.86 | 369 | 110 | 4.38 / 640.82 | 6 | 75 |
8 | 8 | 0.00 | 242 | 14.82 | 301 | 1080 | 5.46 / 641.90 | 6 | 135 |
Average= | 10.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 37 | 14.82 | 446 | 245 | 0.24 / 631.09 | 6 | 13 |
2 | 7 | 2004.40 | 40 | 14.70 | 3024 | 1778 | 2.02 / 632.87 | 13 | 56 |
3 | 13 | 1919.52 | 20 | 14.67 | 2940 | 863 | 2.89 / 633.73 | 5 | 60 |
4 | 13 | 1713.16 | 20 | 14.61 | 2680 | 783 | 3.67 / 634.52 | 5 | 66 |
5 | 13 | 1043.24 | 20 | 14.65 | 1772 | 519 | 4.19 / 635.04 | 5 | 76 |
6 | 13 | 281.92 | 20 | 14.80 | 732 | 217 | 4.40 / 635.25 | 6 | 76 |
7 | 13 | 42.52 | 20 | 14.86 | 380 | 113 | 4.52 / 635.37 | 6 | 73 |
8 | 8 | 0.08 | 238 | 14.82 | 305 | 1076 | 5.59 / 636.44 | 6 | 130 |
Average= | 10.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 37 | 14.83 | 431 | 236 | 0.24 / 625.59 | 6 | 12 |
2 | 7 | 2006.40 | 41 | 14.70 | 3024 | 1823 | 2.06 / 627.41 | 12 | 56 |
3 | 13 | 1923.12 | 20 | 14.66 | 2945 | 863 | 2.92 / 628.27 | 5 | 61 |
4 | 13 | 1602.64 | 20 | 14.62 | 2529 | 739 | 3.66 / 629.01 | 5 | 68 |
5 | 13 | 851.88 | 20 | 14.68 | 1515 | 445 | 4.11 / 629.46 | 5 | 75 |
6 | 13 | 183.76 | 20 | 14.83 | 607 | 180 | 4.29 / 629.64 | 6 | 77 |
7 | 13 | 44.72 | 20 | 14.86 | 389 | 116 | 4.40 / 629.75 | 6 | 74 |
8 | 8 | 0.20 | 240 | 14.82 | 308 | 1095 | 5.50 / 630.85 | 6 | 136 |
Average= | 10.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 37 | 14.84 | 440 | 242 | 0.24 / 620.27 | 6 | 13 |
2 | 7 | 2011.16 | 40 | 14.69 | 3026 | 1778 | 2.02 / 622.05 | 13 | 56 |
3 | 13 | 1933.56 | 20 | 14.65 | 2949 | 864 | 2.88 / 622.91 | 5 | 61 |
4 | 13 | 1401.68 | 20 | 14.65 | 2256 | 661 | 3.54 / 623.57 | 5 | 70 |
5 | 13 | 787.60 | 20 | 14.70 | 1422 | 418 | 3.96 / 623.99 | 6 | 77 |
6 | 13 | 136.32 | 20 | 14.85 | 531 | 158 | 4.12 / 624.15 | 6 | 78 |
7 | 13 | 36.52 | 20 | 14.87 | 366 | 109 | 4.23 / 624.26 | 6 | 72 |
8 | 8 | 0.04 | 240 | 14.83 | 307 | 1093 | 5.32 / 625.35 | 6 | 133 |
Average= | 10.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 37 | 14.82 | 434 | 238 | 0.24 / 614.81 | 6 | 12 |
2 | 7 | 2005.04 | 40 | 14.71 | 3025 | 1780 | 2.02 / 616.58 | 12 | 56 |
3 | 13 | 1922.80 | 20 | 14.67 | 2930 | 860 | 2.88 / 617.44 | 5 | 59 |
4 | 13 | 1501.28 | 20 | 14.64 | 2396 | 702 | 3.58 / 618.15 | 5 | 69 |
5 | 13 | 943.68 | 20 | 14.68 | 1637 | 481 | 4.06 / 618.63 | 6 | 75 |
6 | 13 | 174.96 | 20 | 14.84 | 592 | 176 | 4.24 / 618.80 | 6 | 77 |
7 | 13 | 46.84 | 20 | 14.87 | 385 | 114 | 4.35 / 618.92 | 6 | 73 |
8 | 8 | 0.04 | 242 | 14.83 | 310 | 1113 | 5.46 / 620.03 | 6 | 133 |
Average= | 10.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 37 | 14.84 | 427 | 234 | 0.23 / 609.20 | 6 | 11 |
2 | 7 | 2005.28 | 40 | 14.70 | 3033 | 1783 | 2.02 / 610.98 | 11 | 56 |
3 | 13 | 1920.72 | 20 | 14.66 | 2944 | 863 | 2.88 / 611.85 | 5 | 60 |
4 | 13 | 1493.96 | 20 | 14.64 | 2385 | 698 | 3.58 / 612.55 | 5 | 69 |
5 | 13 | 1053.76 | 20 | 14.65 | 1789 | 524 | 4.10 / 613.07 | 5 | 75 |
6 | 13 | 476.00 | 20 | 14.74 | 1019 | 300 | 4.40 / 613.37 | 6 | 81 |
7 | 13 | 53.72 | 20 | 14.85 | 396 | 118 | 4.52 / 613.49 | 6 | 75 |
8 | 8 | 0.08 | 238 | 14.82 | 306 | 1079 | 5.60 / 614.57 | 6 | 134 |
Average= | 10.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 36 | 14.83 | 439 | 234 | 0.23 / 603.85 | 6 | 11 |
2 | 7 | 2007.56 | 40 | 14.70 | 3033 | 1783 | 2.02 / 605.63 | 11 | 56 |
3 | 13 | 1925.72 | 20 | 14.66 | 2942 | 863 | 2.88 / 606.49 | 5 | 60 |
4 | 13 | 1315.84 | 20 | 14.66 | 2143 | 628 | 3.51 / 607.12 | 5 | 71 |
5 | 13 | 902.60 | 20 | 14.68 | 1579 | 464 | 3.97 / 607.59 | 5 | 76 |
6 | 13 | 141.80 | 20 | 14.84 | 545 | 162 | 4.13 / 607.75 | 6 | 77 |
7 | 13 | 45.84 | 20 | 14.87 | 390 | 116 | 4.25 / 607.86 | 6 | 72 |
8 | 13 | 26.56 | 20 | 14.86 | 354 | 105 | 4.36 / 607.97 | 6 | 72 |
9 | 8 | 0.00 | 220 | 14.82 | 306 | 998 | 5.35 / 608.97 | 6 | 129 |
Average= | 10.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 36 | 14.84 | 428 | 229 | 0.23 / 598.36 | 6 | 11 |
2 | 7 | 2007.72 | 40 | 14.70 | 3043 | 1789 | 2.02 / 600.15 | 11 | 56 |
3 | 13 | 1933.64 | 20 | 14.66 | 2960 | 868 | 2.89 / 601.02 | 5 | 60 |
4 | 13 | 1528.44 | 20 | 14.63 | 2444 | 715 | 3.60 / 601.73 | 5 | 68 |
5 | 13 | 870.48 | 20 | 14.68 | 1546 | 454 | 4.05 / 602.18 | 5 | 76 |
6 | 13 | 210.52 | 20 | 14.82 | 650 | 193 | 4.25 / 602.38 | 6 | 77 |
7 | 13 | 54.64 | 20 | 14.86 | 413 | 123 | 4.37 / 602.50 | 6 | 76 |
8 | 8 | 0.12 | 240 | 14.82 | 313 | 1113 | 5.48 / 603.61 | 6 | 130 |
Average= | 10.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 36 | 14.83 | 431 | 230 | 0.23 / 592.92 | 6 | 11 |
2 | 7 | 2003.80 | 40 | 14.71 | 3034 | 1785 | 2.02 / 594.71 | 11 | 56 |
3 | 13 | 1914.40 | 20 | 14.67 | 2939 | 862 | 2.88 / 595.57 | 5 | 60 |
4 | 13 | 1485.20 | 20 | 14.65 | 2377 | 696 | 3.57 / 596.27 | 5 | 69 |
5 | 13 | 940.76 | 20 | 14.68 | 1640 | 482 | 4.06 / 596.75 | 5 | 76 |
6 | 13 | 186.68 | 20 | 14.84 | 606 | 180 | 4.24 / 596.93 | 6 | 78 |
7 | 13 | 40.84 | 20 | 14.87 | 383 | 114 | 4.35 / 597.04 | 6 | 75 |
8 | 8 | 0.04 | 238 | 14.83 | 308 | 1087 | 5.44 / 598.13 | 6 | 133 |
Average= | 11.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 36 | 14.85 | 424 | 227 | 0.23 / 587.47 | 6 | 11 |
2 | 7 | 2007.44 | 40 | 14.71 | 3039 | 1788 | 2.01 / 589.25 | 11 | 56 |
3 | 13 | 1921.76 | 20 | 14.67 | 2936 | 861 | 2.88 / 590.12 | 5 | 60 |
4 | 13 | 1398.76 | 20 | 14.65 | 2263 | 663 | 3.54 / 590.78 | 5 | 71 |
5 | 13 | 960.36 | 20 | 14.67 | 1665 | 489 | 4.03 / 591.27 | 5 | 76 |
6 | 13 | 289.64 | 20 | 14.80 | 748 | 221 | 4.25 / 591.49 | 6 | 78 |
7 | 13 | 41.52 | 20 | 14.87 | 380 | 113 | 4.36 / 591.60 | 6 | 77 |
8 | 13 | 15.76 | 20 | 14.86 | 333 | 99 | 4.46 / 591.70 | 6 | 74 |
9 | 8 | 0.00 | 219 | 14.82 | 306 | 993 | 5.45 / 592.69 | 6 | 129 |
Average= | 11.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 36 | 14.82 | 435 | 232 | 0.23 / 581.99 | 6 | 11 |
2 | 7 | 2005.36 | 40 | 14.71 | 3038 | 1788 | 2.02 / 583.78 | 11 | 56 |
3 | 13 | 1916.88 | 20 | 14.67 | 2948 | 865 | 2.88 / 584.64 | 5 | 61 |
4 | 13 | 1704.44 | 20 | 14.62 | 2676 | 782 | 3.67 / 585.42 | 5 | 67 |
5 | 13 | 801.00 | 20 | 14.71 | 1463 | 430 | 4.10 / 585.86 | 5 | 77 |
6 | 13 | 167.88 | 20 | 14.85 | 585 | 174 | 4.27 / 586.03 | 6 | 78 |
7 | 13 | 41.16 | 20 | 14.88 | 380 | 113 | 4.38 / 586.14 | 6 | 77 |
8 | 13 | 13.00 | 20 | 14.88 | 329 | 98 | 4.48 / 586.24 | 6 | 74 |
9 | 8 | 0.08 | 218 | 14.83 | 309 | 999 | 5.48 / 587.24 | 6 | 136 |
Average= | 11.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 36 | 14.84 | 424 | 227 | 0.23 / 576.39 | 6 | 10 |
2 | 7 | 2014.32 | 41 | 14.70 | 3051 | 1839 | 2.07 / 578.23 | 10 | 56 |
3 | 13 | 1938.88 | 20 | 14.66 | 2970 | 871 | 2.94 / 579.10 | 5 | 60 |
4 | 13 | 1206.48 | 20 | 14.68 | 2024 | 594 | 3.53 / 579.70 | 5 | 72 |
5 | 13 | 1113.68 | 20 | 14.64 | 1889 | 553 | 4.08 / 580.25 | 5 | 74 |
6 | 13 | 389.92 | 20 | 14.76 | 911 | 269 | 4.35 / 580.52 | 6 | 81 |
7 | 13 | 38.56 | 20 | 14.86 | 388 | 115 | 4.47 / 580.63 | 6 | 76 |
8 | 8 | 0.08 | 240 | 14.81 | 316 | 1123 | 5.59 / 581.76 | 6 | 134 |
Average= | 11.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 36 | 14.85 | 423 | 226 | 0.23 / 570.88 | 6 | 10 |
2 | 7 | 2007.36 | 40 | 14.71 | 3037 | 1787 | 2.01 / 572.67 | 9 | 57 |
3 | 13 | 1928.16 | 20 | 14.67 | 2972 | 872 | 2.89 / 573.54 | 5 | 61 |
4 | 13 | 1507.88 | 20 | 14.64 | 2408 | 705 | 3.59 / 574.24 | 5 | 70 |
5 | 13 | 827.92 | 20 | 14.70 | 1489 | 438 | 4.03 / 574.68 | 5 | 77 |
6 | 13 | 395.96 | 20 | 14.77 | 903 | 267 | 4.29 / 574.95 | 6 | 80 |
7 | 13 | 40.08 | 20 | 14.87 | 377 | 112 | 4.41 / 575.06 | 6 | 76 |
8 | 13 | 14.32 | 20 | 14.87 | 335 | 100 | 4.51 / 575.16 | 6 | 75 |
9 | 8 | 0.16 | 223 | 14.82 | 305 | 1008 | 5.51 / 576.17 | 6 | 134 |
Average= | 11.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 36 | 14.85 | 431 | 230 | 0.23 / 565.47 | 6 | 10 |
2 | 10 | 1015.04 | 3 | 14.99 | 1765 | 79 | 0.31 / 565.55 | 6 | 61 |
3 | 3 | 931.12 | -1 | 15.31 | 0 | 0 | 0.08 / 565.55 | 6 | 61 |
4 | 7 | 2013.76 | 41 | 14.71 | 3043 | 1835 | 2.15 / 567.39 | 61 | 57 |
5 | 13 | 1925.12 | 20 | 14.67 | 2959 | 868 | 3.01 / 568.26 | 5 | 62 |
6 | 13 | 1395.76 | 20 | 14.66 | 2268 | 665 | 3.68 / 568.92 | 5 | 71 |
7 | 13 | 641.16 | 20 | 14.74 | 1235 | 364 | 4.04 / 569.29 | 5 | 78 |
8 | 13 | 231.48 | 20 | 14.82 | 674 | 200 | 4.24 / 569.49 | 6 | 75 |
9 | 13 | 36.00 | 20 | 14.88 | 360 | 107 | 4.35 / 569.59 | 6 | 73 |
10 | 8 | 0.08 | 238 | 14.84 | 300 | 1060 | 5.41 / 570.65 | 6 | 130 |
Average= | 11.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 36 | 14.84 | 426 | 228 | 0.23 / 559.82 | 6 | 9 |
2 | 7 | 2012.80 | 41 | 14.71 | 3032 | 1829 | 2.06 / 561.65 | 9 | 57 |
3 | 13 | 1939.76 | 20 | 14.67 | 2961 | 869 | 2.92 / 562.51 | 5 | 61 |
4 | 13 | 1624.88 | 20 | 14.63 | 2559 | 749 | 3.67 / 563.26 | 5 | 69 |
5 | 13 | 1083.40 | 20 | 14.65 | 1827 | 535 | 4.21 / 563.80 | 5 | 76 |
6 | 13 | 339.80 | 20 | 14.79 | 823 | 243 | 4.45 / 564.04 | 6 | 81 |
7 | 13 | 56.68 | 20 | 14.87 | 404 | 120 | 4.57 / 564.16 | 6 | 77 |
8 | 13 | 32.88 | 20 | 14.86 | 363 | 108 | 4.68 / 564.27 | 6 | 75 |
9 | 8 | 0.12 | 216 | 14.83 | 304 | 974 | 5.65 / 565.24 | 6 | 137 |
Average= | 11.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 36 | 14.84 | 424 | 227 | 0.23 / 554.09 | 6 | 9 |
2 | 7 | 2008.56 | 40 | 14.71 | 3031 | 1783 | 2.01 / 555.87 | 9 | 56 |
3 | 13 | 1924.12 | 20 | 14.68 | 2951 | 866 | 2.88 / 556.74 | 5 | 61 |
4 | 13 | 1622.80 | 20 | 14.64 | 2563 | 750 | 3.63 / 557.49 | 5 | 68 |
5 | 13 | 1048.04 | 20 | 14.67 | 1781 | 523 | 4.15 / 558.01 | 5 | 76 |
6 | 13 | 576.76 | 20 | 14.73 | 1136 | 335 | 4.48 / 558.34 | 5 | 79 |
7 | 13 | 47.60 | 20 | 14.86 | 397 | 118 | 4.60 / 558.46 | 6 | 77 |
8 | 13 | 19.40 | 20 | 14.87 | 347 | 103 | 4.71 / 558.56 | 6 | 73 |
9 | 8 | 0.00 | 223 | 14.82 | 310 | 1025 | 5.73 / 559.59 | 6 | 132 |
Average= | 11.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 36 | 14.84 | 440 | 235 | 0.24 / 548.70 | 6 | 9 |
2 | 7 | 2004.80 | 40 | 14.72 | 3025 | 1781 | 2.02 / 550.48 | 9 | 56 |
3 | 13 | 1916.92 | 20 | 14.68 | 2942 | 864 | 2.88 / 551.34 | 5 | 60 |
4 | 13 | 1294.04 | 20 | 14.68 | 2124 | 624 | 3.50 / 551.97 | 5 | 72 |
5 | 13 | 887.28 | 20 | 14.69 | 1572 | 462 | 3.97 / 552.43 | 5 | 77 |
6 | 13 | 235.00 | 20 | 14.82 | 676 | 200 | 4.17 / 552.63 | 6 | 76 |
7 | 13 | 55.36 | 20 | 14.86 | 410 | 122 | 4.29 / 552.75 | 6 | 76 |
8 | 13 | 14.32 | 20 | 14.87 | 342 | 102 | 4.39 / 552.85 | 6 | 74 |
9 | 8 | 0.12 | 221 | 14.82 | 308 | 1009 | 5.40 / 553.86 | 6 | 133 |
Average= | 12.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 36 | 14.85 | 430 | 230 | 0.23 / 543.17 | 6 | 9 |
2 | 7 | 2014.96 | 40 | 14.72 | 3041 | 1791 | 2.02 / 544.96 | 9 | 56 |
3 | 13 | 1922.56 | 20 | 14.68 | 2933 | 861 | 2.88 / 545.82 | 5 | 61 |
4 | 13 | 1596.76 | 20 | 14.64 | 2521 | 738 | 3.62 / 546.56 | 5 | 68 |
5 | 13 | 839.40 | 20 | 14.71 | 1494 | 440 | 4.06 / 547.00 | 5 | 77 |
6 | 13 | 310.08 | 20 | 14.80 | 783 | 232 | 4.29 / 547.23 | 6 | 79 |
7 | 13 | 44.28 | 20 | 14.87 | 383 | 114 | 4.40 / 547.34 | 6 | 73 |
8 | 13 | 17.48 | 20 | 14.87 | 340 | 101 | 4.51 / 547.44 | 6 | 70 |
9 | 8 | -0.04 | 225 | 14.83 | 305 | 1018 | 5.52 / 548.46 | 6 | 132 |
Average= | 12.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 36 | 14.85 | 434 | 232 | 0.23 / 537.71 | 6 | 9 |
2 | 7 | 2004.96 | 40 | 14.72 | 3014 | 1775 | 2.01 / 539.49 | 9 | 57 |
3 | 13 | 1924.68 | 20 | 14.68 | 2932 | 861 | 2.87 / 540.35 | 5 | 61 |
4 | 13 | 1417.56 | 20 | 14.66 | 2286 | 670 | 3.54 / 541.02 | 5 | 71 |
5 | 13 | 978.68 | 20 | 14.68 | 1684 | 494 | 4.03 / 541.51 | 5 | 76 |
6 | 13 | 218.80 | 20 | 14.83 | 656 | 195 | 4.23 / 541.71 | 6 | 78 |
7 | 13 | 51.44 | 20 | 14.87 | 397 | 118 | 4.34 / 541.83 | 6 | 75 |
8 | 13 | 15.56 | 20 | 14.87 | 335 | 100 | 4.44 / 541.93 | 6 | 73 |
9 | 8 | 0.04 | 223 | 14.83 | 306 | 1012 | 5.46 / 542.94 | 6 | 132 |
Average= | 12.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 36 | 14.85 | 428 | 229 | 0.23 / 532.19 | 6 | 10 |
2 | 7 | 2014.12 | 40 | 14.72 | 3043 | 1792 | 2.02 / 533.98 | 10 | 57 |
3 | 13 | 1924.92 | 20 | 14.68 | 2949 | 866 | 2.89 / 534.85 | 5 | 61 |
4 | 13 | 1617.16 | 20 | 14.64 | 2553 | 748 | 3.63 / 535.59 | 5 | 68 |
5 | 13 | 946.08 | 20 | 14.69 | 1641 | 482 | 4.12 / 536.08 | 5 | 76 |
6 | 13 | 194.92 | 20 | 14.84 | 615 | 183 | 4.30 / 536.26 | 6 | 78 |
7 | 13 | 50.36 | 20 | 14.88 | 390 | 116 | 4.41 / 536.37 | 6 | 73 |
8 | 13 | 14.56 | 20 | 14.88 | 329 | 98 | 4.51 / 536.47 | 6 | 69 |
9 | 8 | 0.24 | 226 | 14.84 | 301 | 1010 | 5.52 / 537.48 | 6 | 131 |
Average= | 12.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 36 | 14.86 | 428 | 229 | 0.23 / 526.85 | 6 | 10 |
2 | 7 | 2005.60 | 40 | 14.72 | 3021 | 1779 | 2.01 / 528.63 | 10 | 57 |
3 | 13 | 1919.92 | 20 | 14.68 | 2945 | 865 | 2.87 / 529.49 | 5 | 61 |
4 | 13 | 1385.08 | 20 | 14.68 | 2234 | 656 | 3.53 / 530.15 | 5 | 71 |
5 | 13 | 853.92 | 20 | 14.71 | 1514 | 445 | 3.97 / 530.59 | 5 | 77 |
6 | 13 | 111.28 | 20 | 14.87 | 490 | 146 | 4.12 / 530.74 | 6 | 76 |
7 | 13 | 60.32 | 20 | 14.88 | 409 | 122 | 4.24 / 530.86 | 6 | 76 |
8 | 13 | 14.88 | 20 | 14.88 | 331 | 99 | 4.34 / 530.96 | 6 | 71 |
9 | 8 | 0.08 | 223 | 14.84 | 302 | 999 | 5.34 / 531.96 | 6 | 130 |
Average= | 12.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 36 | 14.86 | 428 | 229 | 0.23 / 521.54 | 6 | 10 |
2 | 7 | 2019.04 | 40 | 14.72 | 3034 | 1786 | 2.02 / 523.32 | 10 | 57 |
3 | 13 | 1948.08 | 20 | 14.68 | 2965 | 871 | 2.89 / 524.19 | 5 | 60 |
4 | 13 | 1453.32 | 20 | 14.66 | 2329 | 683 | 3.57 / 524.88 | 5 | 70 |
5 | 13 | 738.28 | 20 | 14.73 | 1365 | 402 | 3.97 / 525.28 | 5 | 78 |
6 | 13 | 108.88 | 20 | 14.88 | 496 | 148 | 4.12 / 525.43 | 6 | 76 |
7 | 13 | 33.52 | 20 | 14.89 | 362 | 108 | 4.23 / 525.54 | 6 | 72 |
8 | 8 | 0.12 | 242 | 14.85 | 302 | 1085 | 5.31 / 526.62 | 6 | 130 |
Average= | 12.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 36 | 14.86 | 420 | 225 | 0.22 / 516.08 | 6 | 11 |
2 | 7 | 2007.64 | 40 | 14.73 | 3024 | 1782 | 2.01 / 517.86 | 11 | 57 |
3 | 13 | 1925.12 | 20 | 14.69 | 2939 | 863 | 2.87 / 518.73 | 5 | 60 |
4 | 13 | 1485.52 | 20 | 14.66 | 2368 | 694 | 3.56 / 519.42 | 5 | 69 |
5 | 13 | 938.04 | 20 | 14.70 | 1635 | 481 | 4.04 / 519.90 | 5 | 76 |
6 | 13 | 185.96 | 20 | 14.86 | 614 | 182 | 4.23 / 520.08 | 6 | 78 |
7 | 13 | 44.24 | 20 | 14.89 | 393 | 117 | 4.34 / 520.20 | 6 | 75 |
8 | 8 | 0.08 | 242 | 14.85 | 308 | 1107 | 5.45 / 521.31 | 6 | 138 |
Average= | 13.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 36 | 14.86 | 432 | 231 | 0.23 / 510.63 | 6 | 10 |
2 | 7 | 2005.04 | 40 | 14.72 | 3037 | 1788 | 2.02 / 512.42 | 10 | 56 |
3 | 13 | 1922.48 | 20 | 14.69 | 2934 | 862 | 2.88 / 513.28 | 5 | 60 |
4 | 13 | 1488.28 | 20 | 14.66 | 2391 | 701 | 3.58 / 513.99 | 5 | 70 |
5 | 13 | 950.60 | 20 | 14.69 | 1665 | 489 | 4.07 / 514.47 | 5 | 76 |
6 | 13 | 192.12 | 20 | 14.85 | 621 | 184 | 4.26 / 514.66 | 6 | 77 |
7 | 13 | 47.04 | 20 | 14.89 | 392 | 117 | 4.37 / 514.78 | 6 | 75 |
8 | 8 | 0.12 | 238 | 14.85 | 306 | 1081 | 5.45 / 515.86 | 6 | 130 |
Average= | 13.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 36 | 14.85 | 435 | 233 | 0.23 / 505.28 | 6 | 11 |
2 | 7 | 2005.20 | 40 | 14.72 | 3024 | 1781 | 2.01 / 507.06 | 11 | 56 |
3 | 13 | 1919.00 | 20 | 14.69 | 2935 | 862 | 2.88 / 507.92 | 5 | 61 |
4 | 13 | 1285.56 | 20 | 14.69 | 2105 | 618 | 3.49 / 508.54 | 5 | 72 |
5 | 13 | 972.36 | 20 | 14.69 | 1684 | 495 | 3.99 / 509.03 | 5 | 77 |
6 | 13 | 194.36 | 20 | 14.85 | 612 | 182 | 4.17 / 509.21 | 6 | 79 |
7 | 13 | 51.48 | 20 | 14.89 | 392 | 117 | 4.29 / 509.33 | 6 | 74 |
8 | 8 | 0.12 | 240 | 14.85 | 301 | 1073 | 5.36 / 510.40 | 6 | 132 |
Average= | 13.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 36 | 14.85 | 436 | 233 | 0.23 / 499.72 | 6 | 11 |
2 | 7 | 2003.20 | 40 | 14.73 | 3026 | 1783 | 2.02 / 501.50 | 11 | 58 |
3 | 13 | 1909.52 | 20 | 14.70 | 2926 | 860 | 2.88 / 502.36 | 5 | 62 |
4 | 13 | 1588.12 | 20 | 14.66 | 2503 | 734 | 3.61 / 503.10 | 5 | 68 |
5 | 13 | 930.16 | 20 | 14.71 | 1613 | 475 | 4.08 / 503.57 | 5 | 77 |
6 | 13 | 373.44 | 20 | 14.81 | 866 | 257 | 4.34 / 503.83 | 6 | 80 |
7 | 13 | 62.68 | 20 | 14.88 | 423 | 126 | 4.47 / 503.95 | 6 | 76 |
8 | 8 | -0.12 | 235 | 14.85 | 312 | 1089 | 5.56 / 505.04 | 6 | 139 |
Average= | 13.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 36 | 14.87 | 428 | 229 | 0.23 / 494.31 | 6 | 11 |
2 | 7 | 2014.72 | 40 | 14.72 | 3030 | 1784 | 2.01 / 496.09 | 11 | 57 |
3 | 13 | 1925.36 | 20 | 14.68 | 2953 | 867 | 2.88 / 496.96 | 5 | 61 |
4 | 13 | 1408.32 | 20 | 14.67 | 2265 | 665 | 3.54 / 497.63 | 5 | 70 |
5 | 13 | 874.64 | 20 | 14.71 | 1541 | 453 | 4.00 / 498.08 | 5 | 77 |
6 | 13 | 228.12 | 20 | 14.84 | 665 | 197 | 4.20 / 498.28 | 6 | 76 |
7 | 13 | 57.56 | 20 | 14.88 | 407 | 121 | 4.32 / 498.40 | 6 | 76 |
8 | 8 | 0.04 | 240 | 14.85 | 306 | 1091 | 5.41 / 499.49 | 6 | 131 |
Average= | 13.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 36 | 14.86 | 429 | 229 | 0.23 / 488.91 | 6 | 12 |
2 | 7 | 2014.04 | 40 | 14.72 | 3041 | 1791 | 2.02 / 490.70 | 12 | 57 |
3 | 13 | 1921.08 | 20 | 14.69 | 2940 | 864 | 2.88 / 491.56 | 5 | 62 |
4 | 13 | 1496.44 | 20 | 14.67 | 2389 | 701 | 3.58 / 492.26 | 5 | 70 |
5 | 13 | 960.92 | 20 | 14.69 | 1663 | 489 | 4.07 / 492.75 | 5 | 76 |
6 | 13 | 107.16 | 20 | 14.89 | 485 | 144 | 4.22 / 492.89 | 6 | 75 |
7 | 13 | 63.00 | 20 | 14.89 | 408 | 122 | 4.34 / 493.02 | 6 | 74 |
8 | 8 | 0.12 | 238 | 14.86 | 301 | 1065 | 5.40 / 494.08 | 6 | 132 |
Average= | 14.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 36 | 14.87 | 438 | 234 | 0.23 / 483.46 | 6 | 12 |
2 | 7 | 2007.52 | 40 | 14.73 | 3031 | 1786 | 2.02 / 485.25 | 12 | 58 |
3 | 13 | 1928.76 | 20 | 14.68 | 2958 | 868 | 2.89 / 486.12 | 5 | 61 |
4 | 13 | 1515.52 | 20 | 14.66 | 2422 | 710 | 3.60 / 486.83 | 5 | 70 |
5 | 13 | 874.08 | 20 | 14.71 | 1534 | 451 | 4.05 / 487.28 | 5 | 76 |
6 | 13 | 303.92 | 20 | 14.83 | 761 | 226 | 4.28 / 487.50 | 6 | 78 |
7 | 13 | 45.68 | 20 | 14.89 | 374 | 111 | 4.39 / 487.62 | 6 | 71 |
8 | 8 | 0.16 | 238 | 14.86 | 300 | 1061 | 5.45 / 488.68 | 6 | 138 |
Average= | 14.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 36 | 14.86 | 432 | 231 | 0.23 / 478.11 | 6 | 12 |
2 | 7 | 2014.92 | 40 | 14.73 | 3038 | 1790 | 2.02 / 479.90 | 12 | 57 |
3 | 13 | 1928.08 | 20 | 14.70 | 2941 | 865 | 2.89 / 480.77 | 5 | 60 |
4 | 13 | 1303.16 | 20 | 14.69 | 2131 | 626 | 3.51 / 481.39 | 5 | 72 |
5 | 13 | 991.96 | 20 | 14.69 | 1705 | 501 | 4.01 / 481.89 | 5 | 75 |
6 | 13 | 108.52 | 20 | 14.89 | 484 | 144 | 4.16 / 482.04 | 6 | 77 |
7 | 13 | 62.60 | 20 | 14.89 | 405 | 121 | 4.28 / 482.16 | 6 | 74 |
8 | 8 | 0.04 | 240 | 14.86 | 300 | 1070 | 5.35 / 483.23 | 6 | 132 |
Average= | 14.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 36 | 14.88 | 433 | 232 | 0.23 / 472.58 | 6 | 11 |
2 | 7 | 2008.04 | 40 | 14.74 | 3035 | 1789 | 2.02 / 474.37 | 11 | 56 |
3 | 13 | 1927.76 | 20 | 14.70 | 2937 | 863 | 2.88 / 475.23 | 5 | 60 |
4 | 13 | 1505.48 | 20 | 14.68 | 2393 | 703 | 3.59 / 475.94 | 5 | 68 |
5 | 13 | 857.36 | 20 | 14.72 | 1525 | 449 | 4.04 / 476.39 | 6 | 77 |
6 | 13 | 419.28 | 20 | 14.80 | 940 | 278 | 4.31 / 476.66 | 6 | 80 |
7 | 13 | 47.08 | 20 | 14.89 | 394 | 117 | 4.43 / 476.78 | 6 | 74 |
8 | 8 | 0.12 | 238 | 14.85 | 311 | 1099 | 5.53 / 477.88 | 6 | 134 |
Average= | 14.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 36 | 14.86 | 449 | 240 | 0.24 / 467.13 | 6 | 14 |
2 | 7 | 2013.48 | 40 | 14.74 | 3032 | 1788 | 2.03 / 468.91 | 14 | 56 |
3 | 13 | 1922.80 | 20 | 14.70 | 2934 | 863 | 2.89 / 469.78 | 5 | 60 |
4 | 13 | 1474.76 | 20 | 14.68 | 2365 | 694 | 3.58 / 470.47 | 5 | 69 |
5 | 13 | 937.68 | 20 | 14.72 | 1640 | 483 | 4.07 / 470.95 | 5 | 76 |
6 | 13 | 173.24 | 20 | 14.88 | 592 | 176 | 4.24 / 471.13 | 6 | 78 |
7 | 13 | 42.84 | 20 | 14.91 | 384 | 115 | 4.36 / 471.24 | 6 | 74 |
8 | 8 | 0.04 | 240 | 14.87 | 310 | 1106 | 5.46 / 472.35 | 6 | 134 |
Average= | 15.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 36 | 14.86 | 441 | 236 | 0.24 / 461.47 | 6 | 14 |
2 | 7 | 2006.24 | 40 | 14.74 | 3026 | 1784 | 2.02 / 463.25 | 14 | 56 |
3 | 13 | 1911.44 | 20 | 14.70 | 2918 | 858 | 2.88 / 464.11 | 5 | 61 |
4 | 13 | 1701.76 | 20 | 14.65 | 2659 | 779 | 3.66 / 464.89 | 5 | 66 |
5 | 13 | 986.16 | 20 | 14.71 | 1701 | 500 | 4.16 / 465.39 | 5 | 76 |
6 | 13 | 411.28 | 20 | 14.81 | 921 | 273 | 4.43 / 465.66 | 5 | 82 |
7 | 13 | 38.80 | 20 | 14.90 | 381 | 114 | 4.54 / 465.78 | 6 | 78 |
8 | 8 | -0.16 | 238 | 14.86 | 313 | 1107 | 5.65 / 466.88 | 6 | 136 |
Average= | 15.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 36 | 14.86 | 441 | 236 | 0.24 / 455.78 | 6 | 13 |
2 | 7 | 2011.68 | 40 | 14.73 | 3041 | 1792 | 2.03 / 457.57 | 13 | 57 |
3 | 13 | 1939.04 | 20 | 14.69 | 2961 | 870 | 2.90 / 458.44 | 5 | 61 |
4 | 13 | 1606.92 | 20 | 14.66 | 2543 | 746 | 3.64 / 459.19 | 5 | 69 |
5 | 13 | 1027.80 | 20 | 14.69 | 1761 | 517 | 4.16 / 459.71 | 5 | 77 |
6 | 13 | 569.00 | 20 | 14.76 | 1129 | 333 | 4.49 / 460.04 | 6 | 80 |
7 | 8 | 0.12 | 261 | 14.86 | 308 | 1195 | 5.69 / 461.23 | 6 | 132 |
Average= | 15.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 36 | 14.88 | 426 | 228 | 0.23 / 450.29 | 6 | 11 |
2 | 7 | 2011.36 | 40 | 14.73 | 3041 | 1792 | 2.02 / 452.09 | 11 | 57 |
3 | 13 | 1916.40 | 20 | 14.70 | 2947 | 866 | 2.89 / 452.95 | 5 | 62 |
4 | 13 | 1718.16 | 20 | 14.64 | 2700 | 791 | 3.68 / 453.74 | 5 | 67 |
5 | 13 | 818.76 | 20 | 14.73 | 1473 | 434 | 4.11 / 454.18 | 5 | 77 |
6 | 13 | 166.68 | 20 | 14.87 | 586 | 174 | 4.29 / 454.35 | 6 | 78 |
7 | 13 | 42.44 | 20 | 14.91 | 385 | 115 | 4.40 / 454.47 | 6 | 75 |
8 | 8 | -0.04 | 233 | 14.86 | 312 | 1080 | 5.48 / 455.55 | 6 | 131 |
Average= | 16.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 36 | 14.86 | 449 | 240 | 0.24 / 444.77 | 6 | 12 |
2 | 7 | 2012.40 | 40 | 14.73 | 3047 | 1795 | 2.04 / 446.56 | 12 | 57 |
3 | 13 | 1919.36 | 20 | 14.70 | 2931 | 862 | 2.90 / 447.42 | 5 | 61 |
4 | 13 | 1604.00 | 20 | 14.66 | 2547 | 747 | 3.64 / 448.17 | 5 | 69 |
5 | 13 | 1045.60 | 20 | 14.69 | 1790 | 526 | 4.17 / 448.70 | 5 | 77 |
6 | 13 | 165.60 | 20 | 14.88 | 577 | 172 | 4.34 / 448.87 | 6 | 77 |
7 | 13 | 45.36 | 20 | 14.91 | 367 | 109 | 4.45 / 448.98 | 6 | 68 |
8 | 8 | 0.12 | 246 | 14.88 | 297 | 1087 | 5.54 / 450.07 | 6 | 133 |
Average= | 16.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 36 | 14.87 | 435 | 233 | 0.23 / 439.21 | 6 | 12 |
2 | 7 | 2006.08 | 40 | 14.74 | 3034 | 1789 | 2.02 / 441.00 | 12 | 57 |
3 | 13 | 1933.48 | 20 | 14.70 | 2949 | 867 | 2.89 / 441.86 | 5 | 61 |
4 | 13 | 1517.72 | 20 | 14.67 | 2422 | 711 | 3.60 / 442.57 | 5 | 70 |
5 | 13 | 876.32 | 20 | 14.72 | 1558 | 459 | 4.06 / 443.03 | 5 | 78 |
6 | 13 | 334.80 | 20 | 14.83 | 823 | 244 | 4.30 / 443.28 | 6 | 81 |
7 | 13 | 100.24 | 20 | 14.88 | 485 | 144 | 4.45 / 443.42 | 6 | 79 |
8 | 8 | 0.08 | 242 | 14.86 | 308 | 1108 | 5.55 / 444.53 | 6 | 134 |
Average= | 17.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 36 | 14.87 | 438 | 234 | 0.23 / 433.50 | 6 | 11 |
2 | 7 | 2006.08 | 40 | 14.74 | 3041 | 1793 | 2.03 / 435.29 | 6 | 56 |
3 | 13 | 1921.84 | 20 | 14.70 | 2939 | 864 | 2.89 / 436.16 | 5 | 61 |
4 | 13 | 1619.72 | 20 | 14.66 | 2555 | 749 | 3.64 / 436.91 | 5 | 68 |
5 | 13 | 1143.24 | 20 | 14.68 | 1922 | 564 | 4.20 / 437.47 | 5 | 75 |
6 | 13 | 456.88 | 20 | 14.79 | 995 | 294 | 4.50 / 437.77 | 6 | 80 |
7 | 13 | 55.44 | 20 | 14.91 | 385 | 115 | 4.61 / 437.88 | 6 | 71 |
8 | 8 | 0.12 | 244 | 14.87 | 301 | 1092 | 5.71 / 438.97 | 6 | 139 |
Average= | 17.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.64 | 36 | 14.88 | 443 | 237 | 0.24 / 427.77 | 6 | 12 |
2 | 7 | 2006.00 | 41 | 14.74 | 3026 | 1829 | 2.07 / 429.60 | 12 | 57 |
3 | 13 | 1918.68 | 20 | 14.70 | 2955 | 869 | 2.93 / 430.47 | 5 | 61 |
4 | 13 | 1723.20 | 20 | 14.65 | 2699 | 791 | 3.73 / 431.26 | 5 | 67 |
5 | 13 | 810.44 | 20 | 14.74 | 1462 | 431 | 4.16 / 431.69 | 5 | 78 |
6 | 13 | 616.20 | 20 | 14.76 | 1196 | 353 | 4.51 / 432.04 | 6 | 79 |
7 | 13 | 61.04 | 20 | 14.90 | 410 | 122 | 4.63 / 432.16 | 6 | 74 |
8 | 8 | 0.08 | 242 | 14.87 | 307 | 1105 | 5.74 / 433.27 | 6 | 134 |
Average= | 18.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 36 | 14.89 | 445 | 239 | 0.24 / 422.23 | 6 | 13 |
2 | 7 | 2015.84 | 40 | 14.75 | 3046 | 1797 | 2.04 / 424.03 | 13 | 57 |
3 | 13 | 1936.68 | 20 | 14.70 | 2979 | 876 | 2.91 / 424.91 | 5 | 61 |
4 | 13 | 1732.24 | 20 | 14.65 | 2712 | 795 | 3.71 / 425.70 | 5 | 67 |
5 | 13 | 807.48 | 20 | 14.75 | 1454 | 429 | 4.14 / 426.13 | 5 | 78 |
6 | 13 | 274.32 | 20 | 14.86 | 728 | 216 | 4.35 / 426.35 | 6 | 78 |
7 | 13 | 78.96 | 20 | 14.91 | 431 | 129 | 4.48 / 426.47 | 6 | 75 |
8 | 8 | 0.00 | 235 | 14.88 | 302 | 1056 | 5.54 / 427.53 | 6 | 130 |
Average= | 18.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 37 | 14.87 | 429 | 236 | 0.24 / 416.77 | 6 | 16 |
2 | 7 | 2005.48 | 40 | 14.75 | 3017 | 1780 | 2.02 / 418.55 | 16 | 57 |
3 | 13 | 1922.76 | 20 | 14.71 | 2938 | 864 | 2.88 / 419.41 | 5 | 61 |
4 | 13 | 1402.88 | 20 | 14.71 | 2252 | 663 | 3.54 / 420.07 | 5 | 72 |
5 | 13 | 1083.60 | 20 | 14.70 | 1829 | 538 | 4.08 / 420.61 | 5 | 76 |
6 | 13 | 288.04 | 20 | 14.86 | 751 | 223 | 4.30 / 420.83 | 6 | 80 |
7 | 13 | 45.32 | 20 | 14.93 | 375 | 112 | 4.42 / 420.95 | 6 | 73 |
8 | 8 | 0.16 | 233 | 14.89 | 302 | 1048 | 5.46 / 421.99 | 6 | 129 |
Average= | 19.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 36 | 14.88 | 444 | 238 | 0.24 / 411.20 | 6 | 16 |
2 | 3 | 1018.68 | 1 | 15.06 | 1797 | 27 | 0.26 / 411.23 | 6 | 19 |
3 | 7 | 2014.04 | 40 | 14.75 | 3056 | 1803 | 2.07 / 413.03 | 19 | 58 |
4 | 13 | 1921.20 | 20 | 14.71 | 2951 | 868 | 2.94 / 413.90 | 5 | 61 |
5 | 13 | 1378.60 | 20 | 14.71 | 2233 | 657 | 3.59 / 414.56 | 5 | 71 |
6 | 13 | 865.92 | 20 | 14.75 | 1533 | 452 | 4.05 / 415.01 | 5 | 76 |
7 | 13 | 433.56 | 20 | 14.82 | 958 | 284 | 4.33 / 415.30 | 6 | 81 |
8 | 13 | 40.84 | 20 | 14.92 | 381 | 114 | 4.44 / 415.41 | 6 | 78 |
9 | 8 | 0.00 | 240 | 14.88 | 314 | 1121 | 5.56 / 416.53 | 6 | 131 |
Average= | 19.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 36 | 14.89 | 437 | 234 | 0.23 / 405.15 | 6 | 13 |
2 | 7 | 2020.04 | 40 | 14.75 | 3047 | 1798 | 2.03 / 406.95 | 13 | 58 |
3 | 13 | 1980.72 | 20 | 14.69 | 3022 | 888 | 2.92 / 407.84 | 5 | 61 |
4 | 13 | 1884.68 | 20 | 14.63 | 2897 | 848 | 3.77 / 408.68 | 5 | 64 |
5 | 13 | 1267.80 | 20 | 14.67 | 2076 | 609 | 4.38 / 409.29 | 5 | 74 |
6 | 13 | 800.64 | 20 | 14.71 | 1450 | 427 | 4.80 / 409.72 | 5 | 78 |
7 | 13 | 38.48 | 20 | 14.92 | 381 | 114 | 4.92 / 409.83 | 6 | 78 |
8 | 8 | 0.00 | 244 | 14.88 | 312 | 1133 | 6.05 / 410.97 | 6 | 139 |
Average= | 20.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 36 | 14.90 | 431 | 231 | 0.23 / 399.78 | 6 | 14 |
2 | 7 | 2004.84 | 40 | 14.76 | 3028 | 1788 | 2.02 / 401.57 | 14 | 57 |
3 | 13 | 1921.96 | 20 | 14.72 | 2939 | 865 | 2.88 / 402.43 | 5 | 61 |
4 | 13 | 1310.68 | 20 | 14.71 | 2143 | 630 | 3.51 / 403.06 | 5 | 72 |
5 | 13 | 983.32 | 20 | 14.72 | 1688 | 497 | 4.01 / 403.56 | 5 | 76 |
6 | 13 | 116.08 | 20 | 14.92 | 513 | 153 | 4.16 / 403.72 | 6 | 78 |
7 | 13 | 35.72 | 20 | 14.93 | 377 | 113 | 4.28 / 403.83 | 6 | 74 |
8 | 8 | 0.00 | 233 | 14.89 | 314 | 1089 | 5.37 / 404.92 | 6 | 135 |
Average= | 21.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 36 | 14.89 | 456 | 244 | 0.24 / 394.41 | 6 | 16 |
2 | 7 | 2015.32 | 40 | 14.76 | 3028 | 1788 | 2.03 / 396.20 | 16 | 57 |
3 | 13 | 1928.16 | 20 | 14.72 | 2932 | 863 | 2.90 / 397.06 | 5 | 60 |
4 | 13 | 1368.16 | 20 | 14.72 | 2212 | 651 | 3.55 / 397.72 | 5 | 70 |
5 | 13 | 735.04 | 20 | 14.79 | 1351 | 400 | 3.95 / 398.11 | 6 | 77 |
6 | 13 | 317.84 | 20 | 14.87 | 786 | 234 | 4.18 / 398.35 | 6 | 79 |
7 | 13 | 25.00 | 20 | 14.94 | 362 | 108 | 4.29 / 398.46 | 6 | 76 |
8 | 8 | 0.00 | 233 | 14.90 | 315 | 1094 | 5.38 / 399.55 | 6 | 131 |
Average= | 22.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 36 | 14.87 | 451 | 241 | 0.24 / 388.81 | 6 | 15 |
2 | 7 | 2018.56 | 40 | 14.76 | 3045 | 1798 | 2.04 / 390.61 | 15 | 56 |
3 | 13 | 1937.92 | 20 | 14.72 | 2969 | 874 | 2.91 / 391.49 | 5 | 61 |
4 | 13 | 1490.40 | 20 | 14.70 | 2385 | 701 | 3.61 / 392.19 | 5 | 70 |
5 | 13 | 1029.44 | 20 | 14.72 | 1762 | 519 | 4.13 / 392.71 | 5 | 77 |
6 | 13 | 265.44 | 20 | 14.88 | 714 | 212 | 4.35 / 392.92 | 6 | 77 |
7 | 13 | 27.80 | 20 | 14.94 | 367 | 110 | 4.46 / 393.03 | 6 | 79 |
8 | 8 | 0.00 | 240 | 14.89 | 319 | 1140 | 5.60 / 394.17 | 6 | 136 |
Average= | 23.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 36 | 14.88 | 454 | 243 | 0.24 / 383.03 | 6 | 15 |
2 | 7 | 2008.92 | 41 | 14.76 | 3036 | 1837 | 2.08 / 384.87 | 15 | 57 |
3 | 13 | 1920.68 | 20 | 14.71 | 2958 | 870 | 2.95 / 385.74 | 5 | 62 |
4 | 13 | 1711.12 | 20 | 14.67 | 2679 | 786 | 3.74 / 386.53 | 5 | 67 |
5 | 13 | 910.64 | 20 | 14.75 | 1589 | 469 | 4.21 / 387.00 | 5 | 78 |
6 | 13 | 467.04 | 20 | 14.82 | 1002 | 297 | 4.50 / 387.29 | 6 | 82 |
7 | 13 | 37.44 | 20 | 14.93 | 392 | 117 | 4.62 / 387.41 | 6 | 78 |
8 | 8 | -0.04 | 242 | 14.88 | 323 | 1163 | 5.78 / 388.57 | 6 | 136 |
Average= | 24.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 36 | 14.90 | 450 | 241 | 0.24 / 377.38 | 6 | 16 |
2 | 10 | 1003.68 | 3 | 15.00 | 1754 | 79 | 0.32 / 377.46 | 6 | 59 |
3 | 3 | 938.08 | -1 | 15.34 | 0 | 0 | 0.08 / 377.46 | 6 | 59 |
4 | 7 | 2011.00 | 41 | 14.76 | 3036 | 1837 | 2.16 / 379.29 | 59 | 58 |
5 | 13 | 1933.16 | 20 | 14.72 | 2946 | 867 | 3.02 / 380.16 | 5 | 62 |
6 | 13 | 1390.16 | 20 | 14.72 | 2243 | 660 | 3.69 / 380.82 | 5 | 71 |
7 | 13 | 905.04 | 20 | 14.74 | 1584 | 467 | 4.15 / 381.29 | 5 | 77 |
8 | 13 | 342.24 | 20 | 14.86 | 820 | 244 | 4.40 / 381.53 | 6 | 81 |
9 | 13 | 24.68 | 20 | 14.95 | 365 | 109 | 4.51 / 381.64 | 6 | 77 |
10 | 8 | -0.04 | 242 | 14.89 | 319 | 1149 | 5.65 / 382.79 | 6 | 140 |
Average= | 25.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 36 | 14.89 | 455 | 244 | 0.24 / 371.76 | 6 | 16 |
2 | 7 | 2003.08 | 40 | 14.77 | 3017 | 1782 | 2.03 / 373.54 | 16 | 58 |
3 | 13 | 1905.28 | 20 | 14.73 | 2918 | 860 | 2.89 / 374.40 | 5 | 62 |
4 | 13 | 1274.72 | 20 | 14.74 | 2095 | 618 | 3.50 / 375.02 | 5 | 73 |
5 | 13 | 844.36 | 20 | 14.77 | 1515 | 448 | 3.95 / 375.47 | 5 | 79 |
6 | 13 | 758.60 | 20 | 14.75 | 1392 | 411 | 4.36 / 375.88 | 6 | 80 |
7 | 13 | 34.96 | 20 | 14.93 | 380 | 113 | 4.48 / 375.99 | 6 | 81 |
8 | 8 | 0.00 | 240 | 14.88 | 321 | 1146 | 5.62 / 377.14 | 6 | 133 |
Average= | 26.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 36 | 14.90 | 453 | 243 | 0.24 / 366.12 | 6 | 16 |
2 | 7 | 2008.52 | 41 | 14.76 | 3028 | 1832 | 2.08 / 367.95 | 16 | 58 |
3 | 13 | 1921.80 | 20 | 14.73 | 2948 | 868 | 2.94 / 368.82 | 5 | 62 |
4 | 13 | 1375.04 | 20 | 14.73 | 2223 | 655 | 3.60 / 369.47 | 5 | 71 |
5 | 13 | 1031.88 | 20 | 14.73 | 1760 | 518 | 4.12 / 369.99 | 6 | 77 |
6 | 13 | 425.36 | 20 | 14.85 | 937 | 278 | 4.40 / 370.27 | 6 | 81 |
7 | 13 | 14.64 | 20 | 14.95 | 343 | 103 | 4.50 / 370.37 | 6 | 79 |
8 | 8 | 0.00 | 243 | 14.90 | 315 | 1141 | 5.64 / 371.51 | 6 | 133 |
Average= | 28.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 35 | 14.91 | 441 | 230 | 0.23 / 360.35 | 6 | 14 |
2 | 10 | 1004.84 | 3 | 15.00 | 1754 | 79 | 0.31 / 360.43 | 6 | 56 |
3 | 3 | 922.12 | -1 | 15.35 | 1 | 0 | 0.08 / 360.43 | 6 | 56 |
4 | 7 | 2019.28 | 40 | 14.76 | 3039 | 1794 | 2.10 / 362.22 | 56 | 58 |
5 | 13 | 1949.96 | 20 | 14.72 | 2972 | 875 | 2.98 / 363.10 | 5 | 61 |
6 | 13 | 1430.76 | 20 | 14.71 | 2303 | 678 | 3.66 / 363.78 | 5 | 70 |
7 | 13 | 992.08 | 20 | 14.74 | 1707 | 503 | 4.16 / 364.28 | 5 | 76 |
8 | 13 | 537.68 | 20 | 14.81 | 1082 | 320 | 4.48 / 364.60 | 6 | 79 |
9 | 13 | 33.56 | 20 | 14.94 | 387 | 116 | 4.60 / 364.72 | 6 | 79 |
10 | 8 | 0.04 | 244 | 14.90 | 319 | 1160 | 5.75 / 365.88 | 6 | 131 |
Average= | 30.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 35 | 14.92 | 424 | 221 | 0.22 / 354.78 | 6 | 12 |
2 | 7 | 2012.68 | 41 | 14.76 | 3036 | 1837 | 2.06 / 356.62 | 12 | 58 |
3 | 13 | 1920.88 | 20 | 14.73 | 2945 | 868 | 2.93 / 357.49 | 5 | 62 |
4 | 13 | 1496.56 | 20 | 14.71 | 2387 | 702 | 3.63 / 358.19 | 5 | 70 |
5 | 13 | 1023.16 | 20 | 14.74 | 1736 | 512 | 4.14 / 358.70 | 5 | 77 |
6 | 13 | 171.60 | 20 | 14.92 | 586 | 175 | 4.32 / 358.88 | 6 | 76 |
7 | 13 | 17.04 | 20 | 14.96 | 358 | 107 | 4.42 / 358.98 | 6 | 79 |
8 | 8 | -0.04 | 244 | 14.91 | 313 | 1139 | 5.56 / 360.12 | 6 | 133 |
Average= | 32.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 35 | 14.92 | 444 | 232 | 0.23 / 349.15 | 6 | 11 |
2 | 7 | 2013.40 | 40 | 14.77 | 3045 | 1799 | 2.03 / 350.95 | 11 | 58 |
3 | 13 | 1934.84 | 20 | 14.74 | 2938 | 866 | 2.90 / 351.81 | 5 | 62 |
4 | 13 | 1423.84 | 20 | 14.72 | 2291 | 674 | 3.57 / 352.49 | 5 | 71 |
5 | 13 | 1203.76 | 20 | 14.70 | 1987 | 584 | 4.16 / 353.07 | 5 | 75 |
6 | 13 | 378.80 | 20 | 14.87 | 867 | 258 | 4.41 / 353.33 | 6 | 80 |
7 | 13 | 30.12 | 20 | 14.96 | 360 | 108 | 4.52 / 353.44 | 6 | 77 |
8 | 8 | 0.08 | 248 | 14.92 | 303 | 1121 | 5.64 / 354.56 | 6 | 134 |
Average= | 35.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 35 | 14.93 | 440 | 230 | 0.23 / 343.63 | 6 | 12 |
2 | 7 | 2012.00 | 41 | 14.77 | 3039 | 1840 | 2.07 / 345.47 | 12 | 58 |
3 | 13 | 1926.00 | 20 | 14.74 | 2947 | 869 | 2.94 / 346.34 | 5 | 61 |
4 | 13 | 1384.04 | 20 | 14.73 | 2239 | 660 | 3.60 / 347.00 | 5 | 72 |
5 | 13 | 954.00 | 20 | 14.76 | 1656 | 489 | 4.09 / 347.49 | 5 | 77 |
6 | 13 | 191.52 | 20 | 14.93 | 615 | 184 | 4.27 / 347.67 | 6 | 77 |
7 | 13 | 25.44 | 20 | 14.97 | 365 | 109 | 4.38 / 347.78 | 6 | 77 |
8 | 8 | -0.12 | 246 | 14.92 | 309 | 1134 | 5.51 / 348.92 | 6 | 135 |
Average= | 38.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 35 | 14.93 | 426 | 223 | 0.22 / 338.04 | 6 | 13 |
2 | 7 | 2009.32 | 40 | 14.77 | 3030 | 1790 | 2.01 / 339.83 | 13 | 59 |
3 | 13 | 1913.44 | 20 | 14.74 | 2918 | 860 | 2.87 / 340.69 | 5 | 62 |
4 | 13 | 1701.68 | 20 | 14.69 | 2655 | 780 | 3.65 / 341.47 | 5 | 68 |
5 | 13 | 894.96 | 20 | 14.77 | 1571 | 464 | 4.12 / 341.94 | 5 | 78 |
6 | 13 | 216.60 | 20 | 14.93 | 655 | 196 | 4.31 / 342.13 | 6 | 78 |
7 | 13 | 29.28 | 20 | 14.97 | 375 | 112 | 4.42 / 342.25 | 6 | 77 |
8 | 8 | -0.04 | 244 | 14.92 | 318 | 1158 | 5.58 / 343.40 | 6 | 136 |
Average= | 42.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 35 | 14.93 | 434 | 227 | 0.23 / 332.78 | 6 | 12 |
2 | 7 | 2007.32 | 40 | 14.78 | 3033 | 1793 | 2.02 / 334.57 | 12 | 59 |
3 | 13 | 1812.48 | 20 | 14.75 | 2807 | 828 | 2.85 / 335.40 | 5 | 64 |
4 | 13 | 1201.52 | 20 | 14.77 | 1987 | 587 | 3.43 / 335.99 | 5 | 75 |
5 | 13 | 787.84 | 20 | 14.80 | 1421 | 421 | 3.86 / 336.41 | 6 | 78 |
6 | 13 | 145.88 | 20 | 14.95 | 542 | 162 | 4.02 / 336.57 | 6 | 78 |
7 | 13 | 35.92 | 20 | 14.98 | 379 | 114 | 4.13 / 336.69 | 6 | 76 |
8 | 8 | -0.08 | 242 | 14.93 | 314 | 1135 | 5.27 / 337.82 | 6 | 132 |
Average= | 48.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 36 | 14.95 | 427 | 230 | 0.23 / 327.35 | 6 | 11 |
2 | 7 | 2010.04 | 40 | 14.77 | 3040 | 1796 | 2.03 / 329.15 | 11 | 59 |
3 | 13 | 1924.16 | 20 | 14.74 | 2949 | 869 | 2.90 / 330.02 | 5 | 62 |
4 | 13 | 1395.24 | 20 | 14.73 | 2253 | 664 | 3.56 / 330.68 | 5 | 72 |
5 | 13 | 952.60 | 20 | 14.76 | 1652 | 488 | 4.05 / 331.17 | 5 | 78 |
6 | 13 | 94.36 | 20 | 14.97 | 486 | 146 | 4.19 / 331.32 | 6 | 77 |
7 | 13 | 29.76 | 20 | 14.98 | 375 | 112 | 4.30 / 331.43 | 6 | 75 |
8 | 8 | 0.00 | 238 | 14.93 | 317 | 1126 | 5.43 / 332.55 | 6 | 134 |
Average= | 55.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 36 | 14.95 | 437 | 235 | 0.24 / 321.90 | 6 | 10 |
2 | 7 | 2015.24 | 40 | 14.77 | 3049 | 1801 | 2.04 / 323.70 | 10 | 60 |
3 | 13 | 1926.76 | 20 | 14.74 | 2943 | 868 | 2.90 / 324.57 | 5 | 66 |
4 | 13 | 1391.56 | 20 | 14.74 | 2251 | 664 | 3.57 / 325.23 | 5 | 75 |
5 | 13 | 972.16 | 20 | 14.76 | 1669 | 493 | 4.06 / 325.72 | 5 | 79 |
6 | 13 | 200.64 | 20 | 14.95 | 618 | 185 | 4.25 / 325.91 | 6 | 76 |
7 | 13 | 45.36 | 20 | 14.98 | 386 | 116 | 4.36 / 326.02 | 6 | 76 |
8 | 8 | 0.16 | 242 | 14.95 | 304 | 1100 | 5.46 / 327.12 | 6 | 131 |
Average= | 65.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 36 | 14.95 | 435 | 234 | 0.23 / 316.38 | 6 | 12 |
2 | 7 | 2014.64 | 41 | 14.78 | 3049 | 1848 | 2.08 / 318.23 | 12 | 60 |
3 | 13 | 1921.64 | 20 | 14.75 | 2954 | 871 | 2.95 / 319.10 | 5 | 63 |
4 | 13 | 1482.16 | 20 | 14.73 | 2373 | 699 | 3.65 / 319.80 | 5 | 71 |
5 | 13 | 904.92 | 20 | 14.79 | 1588 | 470 | 4.12 / 320.27 | 5 | 78 |
6 | 13 | 87.44 | 20 | 14.99 | 466 | 140 | 4.26 / 320.41 | 6 | 76 |
7 | 13 | 53.48 | 20 | 14.99 | 407 | 122 | 4.38 / 320.53 | 6 | 75 |
8 | 13 | 14.32 | 20 | 15.00 | 334 | 100 | 4.48 / 320.63 | 6 | 71 |
9 | 8 | -0.04 | 223 | 14.95 | 309 | 1030 | 5.51 / 321.66 | 6 | 135 |
Average= | 80.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 36 | 14.96 | 424 | 228 | 0.23 / 310.83 | 6 | 11 |
2 | 7 | 2004.44 | 40 | 14.79 | 3042 | 1800 | 2.03 / 312.63 | 11 | 58 |
3 | 13 | 1916.96 | 20 | 14.75 | 2933 | 865 | 2.89 / 313.50 | 5 | 62 |
4 | 13 | 1418.48 | 20 | 14.74 | 2282 | 673 | 3.57 / 314.17 | 5 | 71 |
5 | 13 | 787.40 | 20 | 14.82 | 1423 | 422 | 3.99 / 314.59 | 5 | 77 |
6 | 13 | 466.16 | 20 | 14.87 | 998 | 297 | 4.28 / 314.89 | 6 | 81 |
7 | 13 | 44.32 | 20 | 14.99 | 398 | 119 | 4.40 / 315.01 | 6 | 78 |
8 | 8 | 0.08 | 240 | 14.95 | 318 | 1141 | 5.54 / 316.15 | 6 | 130 |
Average= | 105.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 35 | 14.97 | 437 | 229 | 0.23 / 305.06 | 6 | 12 |
2 | 3 | 1019.32 | 1 | 15.11 | 1793 | 27 | 0.26 / 305.09 | 6 | 6 |
3 | 7 | 2004.56 | 41 | 14.79 | 3014 | 1828 | 2.08 / 306.92 | 6 | 59 |
4 | 13 | 1915.32 | 20 | 14.75 | 2937 | 866 | 2.95 / 307.78 | 5 | 63 |
5 | 13 | 1818.92 | 20 | 14.69 | 2819 | 828 | 3.78 / 308.61 | 5 | 67 |
6 | 13 | 922.56 | 20 | 14.80 | 1612 | 477 | 4.26 / 309.09 | 5 | 77 |
7 | 13 | 444.96 | 20 | 14.89 | 965 | 287 | 4.54 / 309.38 | 6 | 82 |
8 | 13 | 38.92 | 20 | 15.00 | 380 | 114 | 4.66 / 309.49 | 6 | 77 |
9 | 8 | 0.12 | 242 | 14.96 | 308 | 1115 | 5.77 / 310.60 | 6 | 133 |
Average= | 155.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 35 | 14.98 | 439 | 230 | 0.23 / 299.47 | 6 | 13 |
2 | 7 | 2009.76 | 40 | 14.79 | 3054 | 1807 | 2.04 / 301.28 | 6 | 58 |
3 | 13 | 1940.60 | 20 | 14.76 | 2967 | 876 | 2.91 / 302.16 | 5 | 62 |
4 | 13 | 1511.84 | 20 | 14.73 | 2418 | 712 | 3.63 / 302.87 | 5 | 71 |
5 | 13 | 960.64 | 20 | 14.79 | 1671 | 494 | 4.12 / 303.36 | 5 | 79 |
6 | 13 | 275.52 | 20 | 14.95 | 738 | 221 | 4.34 / 303.58 | 6 | 79 |
7 | 13 | 33.20 | 20 | 15.01 | 382 | 115 | 4.45 / 303.70 | 6 | 78 |
8 | 8 | 0.08 | 240 | 14.97 | 316 | 1135 | 5.59 / 304.83 | 6 | 134 |
Average= | 304.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 36 | 14.99 | 441 | 238 | 0.24 / 293.92 | 6 | 13 |
2 | 7 | 2008.16 | 40 | 14.79 | 3044 | 1801 | 2.04 / 295.72 | 13 | 59 |
3 | 13 | 1917.96 | 20 | 14.76 | 2935 | 866 | 2.91 / 296.59 | 5 | 64 |
4 | 13 | 1607.76 | 20 | 14.73 | 2550 | 751 | 3.66 / 297.34 | 5 | 70 |
5 | 13 | 916.76 | 20 | 14.81 | 1607 | 476 | 4.13 / 297.82 | 5 | 79 |
6 | 13 | 243.60 | 20 | 14.98 | 699 | 209 | 4.34 / 298.02 | 6 | 79 |
7 | 13 | 28.64 | 20 | 15.04 | 360 | 108 | 4.45 / 298.13 | 6 | 78 |
8 | 8 | 0.04 | 238 | 14.99 | 311 | 1110 | 5.56 / 299.24 | 6 | 138 |
Average= | 9.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 36 | 15.00 | 425 | 229 | 0.23 / 288.30 | 6 | 13 |
2 | 7 | 2010.44 | 40 | 14.79 | 3031 | 1793 | 2.02 / 290.10 | 13 | 58 |
3 | 13 | 1912.20 | 20 | 14.77 | 2915 | 861 | 2.88 / 290.96 | 5 | 63 |
4 | 13 | 1600.00 | 20 | 14.73 | 2536 | 747 | 3.63 / 291.71 | 5 | 71 |
5 | 13 | 1033.08 | 20 | 14.79 | 1761 | 521 | 4.15 / 292.23 | 5 | 77 |
6 | 13 | 325.44 | 20 | 14.96 | 816 | 244 | 4.40 / 292.47 | 6 | 81 |
7 | 13 | 23.92 | 20 | 15.04 | 354 | 106 | 4.50 / 292.58 | 6 | 77 |
8 | 8 | 0.12 | 235 | 14.99 | 314 | 1106 | 5.61 / 293.68 | 6 | 131 |
Average= | 9.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 35 | 15.01 | 443 | 233 | 0.23 / 282.88 | 6 | 14 |
2 | 10 | 1040.88 | 3 | 15.10 | 1788 | 81 | 0.31 / 282.96 | 6 | 60 |
3 | 3 | 1040.96 | 1 | 15.10 | 1824 | 28 | 0.34 / 282.98 | 6 | 33 |
4 | 7 | 2008.08 | 40 | 14.79 | 3045 | 1801 | 2.14 / 284.79 | 33 | 59 |
5 | 13 | 1923.28 | 20 | 14.76 | 2940 | 868 | 3.01 / 285.65 | 5 | 62 |
6 | 13 | 1203.32 | 20 | 14.80 | 1991 | 589 | 3.60 / 286.24 | 5 | 74 |
7 | 13 | 792.52 | 20 | 14.85 | 1426 | 424 | 4.02 / 286.67 | 5 | 79 |
8 | 13 | 227.88 | 20 | 14.99 | 669 | 201 | 4.22 / 286.87 | 6 | 78 |
9 | 13 | 57.24 | 20 | 15.03 | 404 | 121 | 4.35 / 286.99 | 6 | 77 |
10 | 8 | 0.04 | 235 | 15.00 | 308 | 1086 | 5.43 / 288.07 | 6 | 129 |
Average= | 9.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 35 | 15.03 | 434 | 228 | 0.23 / 277.20 | 6 | 13 |
2 | 7 | 2010.48 | 40 | 14.80 | 3037 | 1798 | 2.03 / 279.00 | 13 | 59 |
3 | 13 | 1917.60 | 20 | 14.77 | 2938 | 868 | 2.89 / 279.87 | 5 | 63 |
4 | 13 | 1580.56 | 20 | 14.75 | 2497 | 737 | 3.63 / 280.60 | 5 | 70 |
5 | 13 | 1229.16 | 20 | 14.76 | 2028 | 599 | 4.23 / 281.20 | 5 | 76 |
6 | 13 | 255.64 | 20 | 15.00 | 695 | 208 | 4.44 / 281.41 | 6 | 80 |
7 | 13 | 33.36 | 20 | 15.06 | 369 | 111 | 4.55 / 281.52 | 6 | 79 |
8 | 8 | 0.00 | 238 | 15.01 | 314 | 1122 | 5.67 / 282.64 | 6 | 133 |
Average= | 9.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 35 | 15.03 | 434 | 228 | 0.23 / 271.83 | 6 | 12 |
2 | 7 | 2003.64 | 40 | 14.80 | 3039 | 1799 | 2.03 / 273.63 | 12 | 58 |
3 | 13 | 1918.80 | 20 | 14.77 | 2945 | 870 | 2.90 / 274.50 | 5 | 63 |
4 | 13 | 1316.52 | 20 | 14.78 | 2155 | 637 | 3.53 / 275.14 | 5 | 74 |
5 | 13 | 877.76 | 20 | 14.84 | 1553 | 461 | 4.00 / 275.60 | 5 | 78 |
6 | 13 | 149.00 | 20 | 15.03 | 564 | 170 | 4.16 / 275.77 | 6 | 78 |
7 | 13 | 39.56 | 20 | 15.06 | 379 | 114 | 4.28 / 275.88 | 6 | 76 |
8 | 8 | 0.04 | 235 | 15.03 | 309 | 1091 | 5.37 / 276.97 | 6 | 130 |
Average= | 9.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 35 | 15.04 | 448 | 236 | 0.24 / 266.47 | 6 | 12 |
2 | 7 | 2009.84 | 40 | 14.81 | 3033 | 1797 | 2.03 / 268.27 | 12 | 59 |
3 | 13 | 1716.28 | 20 | 14.79 | 2676 | 792 | 2.82 / 269.06 | 5 | 67 |
4 | 13 | 1405.56 | 20 | 14.78 | 2264 | 669 | 3.49 / 269.73 | 5 | 73 |
5 | 13 | 844.84 | 20 | 14.86 | 1507 | 448 | 3.94 / 270.18 | 6 | 80 |
6 | 13 | 194.88 | 20 | 15.03 | 620 | 186 | 4.13 / 270.37 | 6 | 79 |
7 | 13 | 51.04 | 20 | 15.06 | 397 | 120 | 4.25 / 270.49 | 6 | 77 |
8 | 8 | 0.04 | 238 | 15.03 | 312 | 1116 | 5.36 / 271.60 | 6 | 135 |
Average= | 10.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 35 | 15.05 | 426 | 224 | 0.22 / 261.06 | 6 | 12 |
2 | 7 | 2003.88 | 40 | 14.81 | 3031 | 1796 | 2.02 / 262.86 | 12 | 59 |
3 | 13 | 1908.96 | 20 | 14.78 | 2931 | 866 | 2.89 / 263.72 | 5 | 63 |
4 | 13 | 1471.64 | 20 | 14.77 | 2353 | 695 | 3.58 / 264.42 | 5 | 73 |
5 | 13 | 831.84 | 20 | 14.87 | 1489 | 443 | 4.02 / 264.86 | 6 | 79 |
6 | 13 | 188.24 | 20 | 15.04 | 606 | 182 | 4.21 / 265.04 | 6 | 79 |
7 | 13 | 20.04 | 20 | 15.08 | 342 | 103 | 4.31 / 265.15 | 6 | 73 |
8 | 8 | 0.04 | 235 | 15.04 | 309 | 1092 | 5.40 / 266.24 | 6 | 136 |
Average= | 10.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 35 | 15.04 | 450 | 237 | 0.24 / 255.58 | 6 | 14 |
2 | 7 | 2007.88 | 40 | 14.81 | 3041 | 1801 | 2.04 / 257.38 | 14 | 60 |
3 | 13 | 1915.16 | 20 | 14.78 | 2950 | 872 | 2.91 / 258.25 | 5 | 64 |
4 | 13 | 1481.20 | 20 | 14.77 | 2377 | 702 | 3.61 / 258.96 | 5 | 74 |
5 | 13 | 927.96 | 20 | 14.85 | 1629 | 484 | 4.10 / 259.44 | 5 | 79 |
6 | 13 | 154.32 | 20 | 15.06 | 564 | 170 | 4.27 / 259.61 | 6 | 80 |
7 | 13 | 81.24 | 20 | 15.07 | 447 | 135 | 4.40 / 259.74 | 6 | 80 |
8 | 8 | 0.08 | 235 | 15.04 | 309 | 1092 | 5.49 / 260.84 | 6 | 133 |
Average= | 10.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 35 | 15.05 | 443 | 233 | 0.23 / 250.01 | 6 | 13 |
2 | 7 | 2007.92 | 40 | 14.82 | 3031 | 1797 | 2.03 / 251.81 | 13 | 59 |
3 | 13 | 1923.96 | 20 | 14.78 | 2933 | 867 | 2.90 / 252.67 | 5 | 64 |
4 | 13 | 1725.04 | 20 | 14.73 | 2695 | 794 | 3.69 / 253.47 | 5 | 69 |
5 | 13 | 819.08 | 20 | 14.89 | 1467 | 437 | 4.13 / 253.91 | 5 | 79 |
6 | 13 | 258.76 | 20 | 15.03 | 700 | 210 | 4.34 / 254.12 | 6 | 80 |
7 | 13 | 67.32 | 20 | 15.08 | 422 | 127 | 4.47 / 254.24 | 6 | 80 |
8 | 8 | -0.04 | 236 | 15.05 | 310 | 1101 | 5.57 / 255.34 | 6 | 133 |
Average= | 10.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 35 | 15.05 | 452 | 238 | 0.24 / 244.57 | 6 | 14 |
2 | 7 | 2006.80 | 40 | 14.81 | 3051 | 1807 | 2.05 / 246.37 | 6 | 60 |
3 | 13 | 1918.24 | 20 | 14.78 | 2940 | 869 | 2.91 / 247.24 | 5 | 64 |
4 | 13 | 1384.52 | 20 | 14.79 | 2247 | 665 | 3.58 / 247.91 | 5 | 73 |
5 | 13 | 857.16 | 20 | 14.87 | 1534 | 456 | 4.04 / 248.36 | 5 | 80 |
6 | 13 | 182.92 | 20 | 15.05 | 617 | 186 | 4.22 / 248.55 | 6 | 80 |
7 | 13 | 49.80 | 20 | 15.09 | 397 | 120 | 4.34 / 248.67 | 6 | 78 |
8 | 8 | -0.08 | 233 | 15.05 | 316 | 1108 | 5.45 / 249.78 | 6 | 132 |
Average= | 10.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 35 | 15.06 | 441 | 232 | 0.23 / 239.12 | 6 | 16 |
2 | 7 | 2008.04 | 40 | 14.82 | 3033 | 1798 | 2.03 / 240.92 | 16 | 59 |
3 | 13 | 1919.44 | 20 | 14.79 | 2951 | 873 | 2.90 / 241.79 | 5 | 64 |
4 | 13 | 1392.00 | 20 | 14.80 | 2245 | 665 | 3.57 / 242.46 | 5 | 74 |
5 | 13 | 864.24 | 20 | 14.88 | 1538 | 458 | 4.03 / 242.91 | 5 | 80 |
6 | 13 | 184.08 | 20 | 15.06 | 613 | 185 | 4.21 / 243.10 | 6 | 80 |
7 | 13 | 41.88 | 20 | 15.09 | 390 | 118 | 4.33 / 243.22 | 6 | 79 |
8 | 8 | 0.00 | 233 | 15.05 | 317 | 1112 | 5.44 / 244.33 | 6 | 129 |
Average= | 11.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 35 | 15.07 | 431 | 227 | 0.23 / 233.68 | 6 | 15 |
2 | 7 | 2004.08 | 41 | 14.82 | 3039 | 1847 | 2.07 / 235.53 | 15 | 60 |
3 | 13 | 1911.28 | 20 | 14.79 | 2934 | 868 | 2.94 / 236.39 | 5 | 64 |
4 | 13 | 1474.84 | 20 | 14.78 | 2362 | 698 | 3.64 / 237.09 | 5 | 73 |
5 | 13 | 727.52 | 20 | 14.93 | 1352 | 404 | 4.04 / 237.49 | 5 | 81 |
6 | 13 | 181.24 | 20 | 15.07 | 598 | 180 | 4.22 / 237.68 | 6 | 81 |
7 | 13 | 36.32 | 20 | 15.10 | 378 | 114 | 4.34 / 237.79 | 6 | 79 |
8 | 8 | -0.04 | 231 | 15.06 | 316 | 1099 | 5.44 / 238.89 | 6 | 130 |
Average= | 11.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 35 | 15.07 | 457 | 241 | 0.24 / 228.40 | 6 | 15 |
2 | 7 | 2008.72 | 41 | 14.82 | 3047 | 1851 | 2.09 / 230.25 | 15 | 60 |
3 | 13 | 1724.00 | 20 | 14.80 | 2718 | 805 | 2.90 / 231.05 | 5 | 67 |
4 | 13 | 1295.84 | 20 | 14.82 | 2145 | 636 | 3.53 / 231.69 | 5 | 75 |
5 | 13 | 863.96 | 20 | 14.89 | 1535 | 457 | 3.99 / 232.14 | 5 | 80 |
6 | 13 | 54.64 | 20 | 15.11 | 410 | 124 | 4.11 / 232.27 | 6 | 78 |
7 | 8 | -0.16 | 250 | 15.07 | 314 | 1183 | 5.30 / 233.45 | 6 | 131 |
Average= | 11.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 35 | 15.07 | 448 | 236 | 0.24 / 222.72 | 6 | 17 |
2 | 7 | 2004.36 | 41 | 14.83 | 3038 | 1847 | 2.08 / 224.56 | 6 | 60 |
3 | 13 | 1919.68 | 20 | 14.79 | 2939 | 869 | 2.95 / 225.43 | 5 | 63 |
4 | 13 | 1584.52 | 20 | 14.78 | 2502 | 740 | 3.69 / 226.17 | 5 | 71 |
5 | 13 | 897.08 | 20 | 14.89 | 1578 | 470 | 4.16 / 226.64 | 5 | 79 |
6 | 13 | 445.96 | 20 | 15.00 | 974 | 292 | 4.45 / 226.94 | 6 | 84 |
7 | 13 | 42.84 | 20 | 15.10 | 385 | 116 | 4.57 / 227.05 | 6 | 80 |
8 | 8 | -0.08 | 233 | 15.07 | 314 | 1103 | 5.67 / 228.15 | 6 | 130 |
Average= | 12.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 35 | 15.06 | 461 | 243 | 0.24 / 217.19 | 6 | 17 |
2 | 7 | 2010.00 | 40 | 14.83 | 3065 | 1818 | 2.06 / 219.01 | 6 | 60 |
3 | 13 | 1934.88 | 20 | 14.80 | 2967 | 878 | 2.94 / 219.89 | 5 | 63 |
4 | 13 | 1516.60 | 20 | 14.79 | 2432 | 719 | 3.66 / 220.61 | 5 | 71 |
5 | 13 | 748.04 | 20 | 14.94 | 1381 | 413 | 4.07 / 221.02 | 6 | 80 |
6 | 13 | 196.60 | 20 | 15.08 | 632 | 191 | 4.26 / 221.21 | 6 | 80 |
7 | 13 | 21.32 | 20 | 15.12 | 365 | 110 | 4.37 / 221.32 | 6 | 79 |
8 | 8 | 0.00 | 238 | 15.07 | 324 | 1162 | 5.53 / 222.48 | 6 | 134 |
Average= | 12.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 35 | 15.06 | 457 | 241 | 0.24 / 211.41 | 6 | 17 |
2 | 7 | 2026.44 | 40 | 14.83 | 3071 | 1822 | 2.06 / 213.24 | 17 | 60 |
3 | 13 | 1957.64 | 20 | 14.79 | 2984 | 883 | 2.95 / 214.12 | 5 | 64 |
4 | 13 | 1325.52 | 20 | 14.83 | 2172 | 644 | 3.59 / 214.76 | 5 | 75 |
5 | 13 | 1230.80 | 20 | 14.80 | 2044 | 605 | 4.19 / 215.37 | 5 | 77 |
6 | 13 | 501.24 | 20 | 14.98 | 1053 | 315 | 4.51 / 215.68 | 5 | 85 |
7 | 13 | 23.56 | 20 | 15.11 | 363 | 110 | 4.62 / 215.79 | 6 | 82 |
8 | 8 | -0.08 | 238 | 15.06 | 322 | 1154 | 5.77 / 216.95 | 6 | 133 |
Average= | 12.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 35 | 15.08 | 444 | 234 | 0.23 / 205.36 | 6 | 17 |
2 | 7 | 2010.08 | 40 | 14.84 | 3043 | 1806 | 2.04 / 207.16 | 17 | 60 |
3 | 13 | 1920.84 | 20 | 14.81 | 2939 | 871 | 2.91 / 208.03 | 5 | 64 |
4 | 13 | 1720.16 | 20 | 14.76 | 2698 | 796 | 3.71 / 208.83 | 5 | 69 |
5 | 13 | 1338.20 | 20 | 14.78 | 2188 | 647 | 4.35 / 209.48 | 5 | 76 |
6 | 13 | 824.92 | 20 | 14.89 | 1484 | 442 | 4.80 / 209.92 | 5 | 82 |
7 | 13 | 35.84 | 20 | 15.11 | 379 | 115 | 4.91 / 210.03 | 6 | 82 |
8 | 8 | 0.08 | 240 | 15.07 | 315 | 1139 | 6.05 / 211.17 | 6 | 133 |
Average= | 13.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 35 | 15.08 | 432 | 228 | 0.23 / 199.57 | 6 | 17 |
2 | 7 | 2006.20 | 40 | 14.84 | 3037 | 1803 | 2.03 / 201.38 | 17 | 61 |
3 | 13 | 1825.52 | 20 | 14.81 | 2829 | 838 | 2.87 / 202.21 | 5 | 66 |
4 | 13 | 1739.76 | 20 | 14.76 | 2710 | 800 | 3.67 / 203.01 | 5 | 69 |
5 | 13 | 1137.64 | 20 | 14.84 | 1910 | 567 | 4.24 / 203.58 | 5 | 79 |
6 | 13 | 416.40 | 20 | 15.02 | 944 | 284 | 4.52 / 203.86 | 6 | 85 |
7 | 13 | 29.20 | 20 | 15.12 | 376 | 114 | 4.63 / 203.98 | 6 | 81 |
8 | 8 | 0.04 | 235 | 15.07 | 323 | 1144 | 5.78 / 205.12 | 6 | 129 |
Average= | 13.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 35 | 15.09 | 437 | 231 | 0.23 / 194.09 | 6 | 17 |
2 | 7 | 2005.48 | 40 | 14.85 | 3040 | 1806 | 2.04 / 195.89 | 17 | 61 |
3 | 13 | 1919.04 | 20 | 14.81 | 2936 | 870 | 2.91 / 196.76 | 5 | 64 |
4 | 13 | 1471.52 | 20 | 14.82 | 2358 | 699 | 3.61 / 197.46 | 5 | 72 |
5 | 13 | 907.64 | 20 | 14.90 | 1591 | 474 | 4.08 / 197.94 | 5 | 80 |
6 | 13 | 149.52 | 20 | 15.10 | 559 | 169 | 4.25 / 198.10 | 6 | 80 |
7 | 13 | 25.72 | 20 | 15.13 | 367 | 111 | 4.36 / 198.22 | 6 | 80 |
8 | 8 | 0.16 | 235 | 15.08 | 319 | 1130 | 5.49 / 199.35 | 6 | 131 |
Average= | 14.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 35 | 15.09 | 443 | 234 | 0.23 / 188.69 | 6 | 15 |
2 | 7 | 2013.24 | 40 | 14.84 | 3056 | 1814 | 2.05 / 190.50 | 15 | 60 |
3 | 13 | 1917.04 | 20 | 14.81 | 2951 | 874 | 2.92 / 191.38 | 5 | 64 |
4 | 13 | 1292.44 | 20 | 14.85 | 2130 | 633 | 3.55 / 192.01 | 5 | 76 |
5 | 13 | 861.52 | 20 | 14.92 | 1535 | 458 | 4.01 / 192.47 | 5 | 81 |
6 | 13 | 92.08 | 20 | 15.12 | 472 | 143 | 4.16 / 192.61 | 6 | 81 |
7 | 13 | 28.04 | 20 | 15.14 | 368 | 111 | 4.27 / 192.72 | 6 | 79 |
8 | 8 | 0.00 | 238 | 15.09 | 316 | 1135 | 5.40 / 193.86 | 6 | 135 |
Average= | 14.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 34 | 15.10 | 427 | 219 | 0.22 / 183.13 | 6 | 15 |
2 | 7 | 2004.96 | 40 | 14.85 | 3043 | 1808 | 2.03 / 184.94 | 6 | 60 |
3 | 13 | 1913.12 | 20 | 14.81 | 2940 | 871 | 2.90 / 185.81 | 5 | 65 |
4 | 13 | 1490.60 | 20 | 14.82 | 2379 | 705 | 3.60 / 186.52 | 5 | 73 |
5 | 13 | 826.16 | 20 | 14.94 | 1484 | 443 | 4.05 / 186.96 | 5 | 81 |
6 | 13 | 276.40 | 20 | 15.07 | 742 | 224 | 4.27 / 187.18 | 6 | 82 |
7 | 13 | 37.80 | 20 | 15.13 | 394 | 119 | 4.39 / 187.30 | 6 | 81 |
8 | 8 | -0.08 | 235 | 15.09 | 325 | 1152 | 5.54 / 188.45 | 6 | 139 |
Average= | 15.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 35 | 15.10 | 429 | 227 | 0.23 / 177.68 | 6 | 16 |
2 | 7 | 2005.40 | 40 | 14.84 | 3049 | 1810 | 2.04 / 179.49 | 16 | 63 |
3 | 13 | 1915.28 | 20 | 14.81 | 2946 | 873 | 2.91 / 180.36 | 5 | 66 |
4 | 13 | 1493.56 | 20 | 14.82 | 2388 | 708 | 3.62 / 181.07 | 5 | 74 |
5 | 13 | 836.56 | 20 | 14.94 | 1493 | 446 | 4.06 / 181.52 | 5 | 81 |
6 | 13 | 163.16 | 20 | 15.11 | 567 | 171 | 4.23 / 181.69 | 6 | 80 |
7 | 13 | 37.80 | 20 | 15.14 | 385 | 117 | 4.35 / 181.81 | 6 | 82 |
8 | 8 | -0.04 | 235 | 15.10 | 312 | 1107 | 5.46 / 182.91 | 6 | 132 |
Average= | 16.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 34 | 15.11 | 460 | 236 | 0.24 / 172.29 | 6 | 15 |
2 | 7 | 2007.88 | 40 | 14.85 | 3050 | 1812 | 2.05 / 174.11 | 15 | 62 |
3 | 13 | 1923.72 | 20 | 14.81 | 2959 | 876 | 2.92 / 174.98 | 5 | 65 |
4 | 13 | 1400.68 | 20 | 14.84 | 2275 | 675 | 3.60 / 175.66 | 5 | 74 |
5 | 13 | 840.56 | 20 | 14.94 | 1494 | 446 | 4.05 / 176.10 | 5 | 81 |
6 | 13 | 88.24 | 20 | 15.14 | 463 | 140 | 4.19 / 176.24 | 6 | 80 |
7 | 13 | 30.96 | 20 | 15.15 | 372 | 113 | 4.30 / 176.36 | 6 | 80 |
8 | 8 | 0.00 | 233 | 15.10 | 312 | 1098 | 5.40 / 177.45 | 6 | 134 |
Average= | 17.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 34 | 15.10 | 437 | 224 | 0.22 / 166.92 | 6 | 15 |
2 | 7 | 2018.16 | 41 | 14.85 | 3053 | 1859 | 2.08 / 168.77 | 15 | 61 |
3 | 13 | 1941.00 | 20 | 14.81 | 2980 | 883 | 2.97 / 169.66 | 5 | 65 |
4 | 13 | 1305.88 | 20 | 14.86 | 2149 | 639 | 3.60 / 170.30 | 5 | 76 |
5 | 13 | 792.40 | 20 | 14.95 | 1443 | 431 | 4.04 / 170.73 | 5 | 82 |
6 | 13 | 44.04 | 20 | 15.15 | 401 | 122 | 4.16 / 170.85 | 6 | 79 |
7 | 13 | 17.84 | 20 | 15.15 | 352 | 107 | 4.26 / 170.95 | 6 | 80 |
8 | 8 | -0.04 | 231 | 15.11 | 316 | 1103 | 5.37 / 172.06 | 6 | 129 |
Average= | 19.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 34 | 15.10 | 440 | 226 | 0.23 / 161.32 | 6 | 17 |
2 | 7 | 2016.08 | 40 | 14.85 | 3058 | 1816 | 2.04 / 163.14 | 17 | 61 |
3 | 13 | 1930.00 | 20 | 14.82 | 2965 | 879 | 2.92 / 164.02 | 5 | 65 |
4 | 13 | 1391.12 | 20 | 14.85 | 2254 | 669 | 3.59 / 164.68 | 5 | 75 |
5 | 13 | 1069.36 | 20 | 14.88 | 1817 | 541 | 4.13 / 165.23 | 5 | 81 |
6 | 13 | 243.08 | 20 | 15.09 | 685 | 207 | 4.34 / 165.43 | 6 | 82 |
7 | 13 | 27.84 | 20 | 15.15 | 370 | 112 | 4.45 / 165.54 | 6 | 83 |
8 | 8 | 0.04 | 238 | 15.10 | 319 | 1146 | 5.60 / 166.69 | 6 | 133 |
Average= | 20.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 34 | 15.12 | 455 | 234 | 0.23 / 155.81 | 6 | 15 |
2 | 7 | 2007.96 | 40 | 14.85 | 3061 | 1818 | 2.05 / 157.62 | 15 | 61 |
3 | 13 | 1918.36 | 20 | 14.82 | 2950 | 874 | 2.93 / 158.50 | 5 | 67 |
4 | 13 | 1192.12 | 20 | 14.89 | 1999 | 595 | 3.52 / 159.09 | 5 | 79 |
5 | 13 | 784.60 | 20 | 14.96 | 1437 | 430 | 3.95 / 159.52 | 5 | 83 |
6 | 13 | 436.48 | 20 | 15.04 | 963 | 290 | 4.24 / 159.81 | 6 | 87 |
7 | 13 | 40.48 | 20 | 15.14 | 396 | 120 | 4.36 / 159.93 | 6 | 84 |
8 | 8 | 0.24 | 236 | 15.09 | 326 | 1161 | 5.52 / 161.09 | 6 | 130 |
Average= | 23.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 34 | 15.14 | 444 | 229 | 0.23 / 150.32 | 6 | 14 |
2 | 7 | 2003.88 | 40 | 14.85 | 3063 | 1819 | 2.05 / 152.14 | 6 | 61 |
3 | 13 | 1921.48 | 20 | 14.82 | 2967 | 879 | 2.93 / 153.02 | 5 | 66 |
4 | 13 | 1384.16 | 20 | 14.85 | 2250 | 668 | 3.60 / 153.69 | 5 | 78 |
5 | 13 | 940.60 | 20 | 14.92 | 1649 | 492 | 4.09 / 154.18 | 5 | 82 |
6 | 13 | 67.84 | 20 | 15.15 | 436 | 132 | 4.22 / 154.31 | 6 | 82 |
7 | 13 | 22.64 | 20 | 15.16 | 365 | 111 | 4.33 / 154.42 | 6 | 80 |
8 | 8 | 0.04 | 238 | 15.11 | 320 | 1151 | 5.48 / 155.57 | 6 | 137 |
Average= | 25.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 34 | 15.18 | 434 | 224 | 0.22 / 144.93 | 6 | 14 |
2 | 7 | 2019.64 | 40 | 14.86 | 3054 | 1815 | 2.04 / 146.74 | 14 | 62 |
3 | 13 | 1941.84 | 20 | 14.83 | 2980 | 884 | 2.92 / 147.63 | 5 | 66 |
4 | 13 | 1420.00 | 20 | 14.85 | 2297 | 682 | 3.61 / 148.31 | 5 | 77 |
5 | 13 | 779.88 | 20 | 14.99 | 1420 | 426 | 4.03 / 148.74 | 5 | 83 |
6 | 13 | 59.28 | 20 | 15.18 | 417 | 127 | 4.16 / 148.86 | 6 | 82 |
7 | 13 | 37.84 | 20 | 15.17 | 388 | 118 | 4.28 / 148.98 | 6 | 82 |
8 | 8 | 0.08 | 233 | 15.13 | 315 | 1110 | 5.39 / 150.09 | 6 | 129 |
Average= | 30.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 34 | 15.18 | 453 | 234 | 0.23 / 140.18 | 6 | 15 |
2 | 7 | 1508.96 | 40 | 15.01 | 2382 | 1430 | 1.66 / 141.61 | 15 | 65 |
3 | 13 | 1447.52 | 20 | 14.99 | 2302 | 690 | 2.35 / 142.30 | 5 | 69 |
4 | 13 | 1354.00 | 20 | 14.96 | 2175 | 651 | 3.00 / 142.95 | 5 | 73 |
5 | 13 | 794.64 | 20 | 15.05 | 1432 | 431 | 3.44 / 143.38 | 5 | 82 |
6 | 13 | 36.64 | 20 | 15.23 | 394 | 120 | 3.56 / 143.50 | 6 | 79 |
7 | 13 | 13.44 | 20 | 15.23 | 353 | 108 | 3.66 / 143.61 | 6 | 80 |
8 | 8 | 0.04 | 223 | 15.18 | 324 | 1097 | 4.76 / 144.70 | 6 | 131 |
Average= | 36.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 34 | 15.17 | 448 | 231 | 0.23 / 135.41 | 6 | 14 |
2 | 7 | 1505.60 | 41 | 15.02 | 2381 | 1466 | 1.70 / 136.88 | 6 | 65 |
3 | 13 | 1438.72 | 20 | 14.99 | 2301 | 690 | 2.39 / 137.57 | 5 | 69 |
4 | 13 | 1343.80 | 20 | 14.96 | 2171 | 650 | 3.04 / 138.22 | 5 | 74 |
5 | 13 | 685.00 | 20 | 15.08 | 1281 | 386 | 3.42 / 138.60 | 6 | 82 |
6 | 13 | 64.96 | 20 | 15.22 | 433 | 132 | 3.55 / 138.73 | 6 | 81 |
7 | 13 | 18.08 | 20 | 15.23 | 355 | 108 | 3.66 / 138.84 | 6 | 79 |
8 | 8 | 0.12 | 227 | 15.18 | 320 | 1103 | 4.77 / 139.94 | 6 | 132 |
Average= | 46.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 32 | 15.18 | 453 | 220 | 0.22 / 130.53 | 6 | 16 |
2 | 10 | 1023.64 | 3 | 15.16 | 1756 | 80 | 0.30 / 130.61 | 6 | 58 |
3 | 7 | 1514.72 | 40 | 15.02 | 2394 | 1438 | 1.74 / 132.05 | 58 | 64 |
4 | 13 | 1469.56 | 20 | 14.99 | 2336 | 700 | 2.44 / 132.75 | 5 | 69 |
5 | 13 | 1378.68 | 20 | 14.96 | 2232 | 668 | 3.11 / 133.42 | 5 | 73 |
6 | 13 | 712.88 | 20 | 15.06 | 1323 | 398 | 3.50 / 133.82 | 5 | 83 |
7 | 13 | 71.16 | 20 | 15.22 | 442 | 135 | 3.64 / 133.95 | 6 | 81 |
8 | 13 | 20.44 | 20 | 15.23 | 358 | 109 | 3.75 / 134.06 | 6 | 81 |
9 | 8 | 0.04 | 229 | 15.18 | 321 | 1116 | 4.86 / 135.18 | 6 | 134 |
Average= | 67.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 31 | 15.14 | 441 | 207 | 0.21 / 127.49 | 6 | 14 |
2 | 10 | 1035.60 | 3 | 15.14 | 1791 | 81 | 0.29 / 127.57 | 6 | 57 |
3 | 3 | 1029.16 | 1 | 15.18 | 1820 | 28 | 0.32 / 127.60 | 5 | 20 |
4 | 7 | 1010.48 | 40 | 15.09 | 1724 | 1041 | 1.36 / 128.64 | 20 | 76 |
5 | 13 | 594.52 | 20 | 15.14 | 1175 | 356 | 1.71 / 129.00 | 6 | 81 |
6 | 13 | 34.76 | 20 | 15.26 | 382 | 117 | 1.83 / 129.11 | 6 | 80 |
7 | 13 | 13.80 | 20 | 15.25 | 347 | 106 | 1.93 / 129.22 | 6 | 80 |
8 | 8 | 0.04 | 225 | 15.21 | 320 | 1095 | 3.03 / 130.31 | 6 | 136 |
Average= | 130.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 34 | 15.13 | 433 | 223 | 0.22 / 122.05 | 6 | 17 |
2 | 7 | 2011.56 | 40 | 14.88 | 3048 | 1814 | 2.04 / 123.86 | 17 | 63 |
3 | 13 | 1913.60 | 20 | 14.85 | 2924 | 868 | 2.91 / 124.73 | 5 | 69 |
4 | 13 | 1468.68 | 20 | 14.87 | 2351 | 699 | 3.60 / 125.43 | 5 | 78 |
5 | 13 | 906.12 | 20 | 14.96 | 1600 | 479 | 4.08 / 125.91 | 5 | 84 |
6 | 13 | 119.04 | 20 | 15.16 | 509 | 154 | 4.24 / 126.06 | 6 | 84 |
7 | 13 | 26.04 | 20 | 15.18 | 361 | 110 | 4.35 / 126.17 | 6 | 82 |
8 | 8 | 0.04 | 233 | 15.13 | 316 | 1114 | 5.46 / 127.28 | 6 | 132 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 34 | 15.19 | 441 | 228 | 0.23 / 116.67 | 6 | 14 |
2 | 7 | 2006.00 | 40 | 14.89 | 3041 | 1811 | 2.04 / 118.48 | 6 | 64 |
3 | 13 | 1920.48 | 20 | 14.85 | 2946 | 875 | 2.91 / 119.36 | 5 | 69 |
4 | 13 | 1293.36 | 20 | 14.91 | 2118 | 632 | 3.55 / 119.99 | 5 | 79 |
5 | 13 | 679.80 | 20 | 15.02 | 1285 | 386 | 3.93 / 120.38 | 5 | 86 |
6 | 13 | 231.36 | 20 | 15.13 | 665 | 201 | 4.13 / 120.58 | 6 | 83 |
7 | 13 | 26.20 | 20 | 15.18 | 368 | 112 | 4.24 / 120.69 | 6 | 82 |
8 | 8 | -0.04 | 235 | 15.13 | 319 | 1134 | 5.38 / 121.82 | 6 | 133 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 34 | 15.15 | 449 | 231 | 0.23 / 111.29 | 6 | 20 |
2 | 7 | 2009.28 | 40 | 14.89 | 3047 | 1815 | 2.05 / 113.10 | 20 | 66 |
3 | 13 | 1917.20 | 20 | 14.85 | 2952 | 877 | 2.92 / 113.98 | 5 | 70 |
4 | 13 | 1485.44 | 20 | 14.87 | 2370 | 705 | 3.63 / 114.68 | 5 | 79 |
5 | 13 | 708.24 | 20 | 15.02 | 1317 | 396 | 4.02 / 115.08 | 5 | 85 |
6 | 13 | 162.52 | 20 | 15.16 | 574 | 174 | 4.20 / 115.25 | 6 | 84 |
7 | 13 | 17.12 | 20 | 15.19 | 349 | 106 | 4.30 / 115.36 | 6 | 82 |
8 | 8 | -0.08 | 229 | 15.15 | 313 | 1086 | 5.39 / 116.44 | 6 | 129 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 34 | 15.16 | 447 | 230 | 0.23 / 105.96 | 6 | 19 |
2 | 7 | 2015.96 | 40 | 14.88 | 3053 | 1817 | 2.05 / 107.77 | 19 | 66 |
3 | 13 | 1934.92 | 20 | 14.85 | 2970 | 882 | 2.93 / 108.66 | 5 | 71 |
4 | 13 | 1315.00 | 20 | 14.91 | 2151 | 641 | 3.57 / 109.30 | 5 | 83 |
5 | 13 | 781.12 | 20 | 15.00 | 1421 | 426 | 4.00 / 109.72 | 5 | 87 |
6 | 13 | 112.64 | 20 | 15.17 | 498 | 151 | 4.15 / 109.88 | 6 | 82 |
7 | 8 | 0.04 | 248 | 15.15 | 314 | 1180 | 5.33 / 111.06 | 6 | 134 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 34 | 15.15 | 436 | 225 | 0.22 / 100.58 | 6 | 19 |
2 | 7 | 2008.16 | 40 | 14.90 | 3044 | 1814 | 2.04 / 102.40 | 19 | 67 |
3 | 13 | 1927.12 | 20 | 14.86 | 2953 | 878 | 2.92 / 103.28 | 5 | 71 |
4 | 13 | 1393.08 | 20 | 14.90 | 2261 | 674 | 3.59 / 103.95 | 5 | 82 |
5 | 13 | 749.80 | 20 | 15.02 | 1380 | 415 | 4.00 / 104.36 | 5 | 87 |
6 | 13 | 104.36 | 20 | 15.18 | 489 | 148 | 4.15 / 104.51 | 6 | 83 |
7 | 13 | 29.28 | 20 | 15.20 | 374 | 114 | 4.27 / 104.63 | 6 | 82 |
8 | 8 | -0.04 | 227 | 15.15 | 320 | 1100 | 5.37 / 105.73 | 6 | 130 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 35 | 15.15 | 446 | 236 | 0.24 / 95.16 | 6 | 21 |
2 | 7 | 2010.48 | 40 | 14.90 | 3050 | 1818 | 2.05 / 96.98 | 21 | 67 |
3 | 13 | 1912.96 | 20 | 14.87 | 2954 | 879 | 2.93 / 97.85 | 5 | 72 |
4 | 13 | 1461.76 | 20 | 14.89 | 2355 | 701 | 3.63 / 98.55 | 5 | 81 |
5 | 13 | 807.04 | 20 | 15.01 | 1467 | 440 | 4.07 / 99.00 | 5 | 86 |
6 | 13 | 67.72 | 20 | 15.20 | 437 | 133 | 4.21 / 99.13 | 6 | 83 |
7 | 13 | 20.28 | 20 | 15.20 | 363 | 110 | 4.32 / 99.24 | 6 | 83 |
8 | 8 | -0.04 | 229 | 15.16 | 323 | 1121 | 5.44 / 100.36 | 6 | 131 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 34 | 15.16 | 439 | 226 | 0.23 / 89.80 | 6 | 18 |
2 | 7 | 2005.40 | 40 | 14.90 | 3038 | 1811 | 2.04 / 91.61 | 18 | 67 |
3 | 13 | 1809.84 | 20 | 14.88 | 2828 | 842 | 2.88 / 92.45 | 5 | 75 |
4 | 13 | 1196.76 | 20 | 14.95 | 1991 | 595 | 3.47 / 93.05 | 5 | 84 |
5 | 13 | 865.16 | 20 | 14.99 | 1536 | 460 | 3.93 / 93.51 | 5 | 86 |
6 | 13 | 187.28 | 20 | 15.16 | 611 | 185 | 4.12 / 93.69 | 6 | 82 |
7 | 13 | 21.60 | 20 | 15.20 | 365 | 111 | 4.23 / 93.80 | 6 | 83 |
8 | 8 | 0.00 | 229 | 15.15 | 322 | 1117 | 5.35 / 94.92 | 6 | 129 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 34 | 15.17 | 443 | 228 | 0.23 / 84.43 | 6 | 17 |
2 | 7 | 2012.92 | 40 | 14.90 | 3055 | 1821 | 2.05 / 86.25 | 17 | 67 |
3 | 13 | 1933.24 | 20 | 14.87 | 2973 | 884 | 2.93 / 87.14 | 5 | 72 |
4 | 13 | 1290.32 | 20 | 14.93 | 2127 | 635 | 3.57 / 87.77 | 5 | 83 |
5 | 13 | 748.76 | 20 | 15.03 | 1376 | 414 | 3.98 / 88.19 | 5 | 87 |
6 | 13 | 102.60 | 20 | 15.19 | 497 | 151 | 4.13 / 88.34 | 6 | 83 |
7 | 13 | 27.08 | 20 | 15.21 | 367 | 112 | 4.24 / 88.45 | 6 | 83 |
8 | 8 | 0.00 | 231 | 15.16 | 321 | 1124 | 5.37 / 89.57 | 6 | 129 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 34 | 15.18 | 430 | 222 | 0.22 / 79.00 | 6 | 16 |
2 | 7 | 2013.92 | 40 | 14.90 | 3055 | 1821 | 2.04 / 80.82 | 16 | 67 |
3 | 13 | 1920.76 | 20 | 14.87 | 2950 | 877 | 2.92 / 81.69 | 5 | 72 |
4 | 13 | 1404.48 | 20 | 14.91 | 2275 | 678 | 3.60 / 82.37 | 5 | 83 |
5 | 13 | 852.72 | 20 | 15.00 | 1521 | 456 | 4.05 / 82.83 | 5 | 87 |
6 | 13 | 83.52 | 20 | 15.20 | 456 | 139 | 4.19 / 82.97 | 6 | 83 |
7 | 13 | 45.68 | 20 | 15.20 | 396 | 120 | 4.31 / 83.09 | 6 | 83 |
8 | 8 | 0.04 | 233 | 15.17 | 316 | 1117 | 5.43 / 84.20 | 6 | 130 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 34 | 15.17 | 442 | 228 | 0.23 / 73.56 | 6 | 18 |
2 | 7 | 2006.52 | 40 | 14.91 | 3054 | 1821 | 2.05 / 75.38 | 18 | 67 |
3 | 13 | 1914.64 | 20 | 14.89 | 2957 | 881 | 2.93 / 76.26 | 5 | 73 |
4 | 13 | 1485.12 | 20 | 14.90 | 2388 | 712 | 3.64 / 76.97 | 5 | 81 |
5 | 13 | 747.88 | 20 | 15.04 | 1384 | 416 | 4.06 / 77.39 | 5 | 88 |
6 | 13 | 102.28 | 20 | 15.20 | 493 | 150 | 4.21 / 77.54 | 6 | 83 |
7 | 13 | 35.04 | 20 | 15.21 | 379 | 115 | 4.32 / 77.65 | 6 | 81 |
8 | 8 | 0.08 | 235 | 15.17 | 314 | 1119 | 5.44 / 78.77 | 6 | 131 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 34 | 15.17 | 450 | 232 | 0.23 / 67.95 | 6 | 19 |
2 | 7 | 2021.04 | 41 | 14.91 | 3063 | 1872 | 2.10 / 69.82 | 19 | 67 |
3 | 13 | 1933.88 | 20 | 14.88 | 2980 | 887 | 2.99 / 70.71 | 5 | 72 |
4 | 13 | 1391.40 | 20 | 14.92 | 2269 | 677 | 3.67 / 71.38 | 5 | 83 |
5 | 13 | 1062.72 | 20 | 14.96 | 1816 | 543 | 4.21 / 71.93 | 5 | 85 |
6 | 13 | 122.20 | 20 | 15.19 | 527 | 160 | 4.37 / 72.09 | 6 | 85 |
7 | 13 | 32.56 | 20 | 15.21 | 377 | 115 | 4.49 / 72.20 | 6 | 83 |
8 | 8 | 0.00 | 231 | 15.17 | 322 | 1128 | 5.61 / 73.33 | 6 | 129 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 34 | 15.18 | 449 | 232 | 0.23 / 62.48 | 6 | 19 |
2 | 7 | 2006.48 | 40 | 14.92 | 3040 | 1814 | 2.05 / 64.30 | 19 | 67 |
3 | 13 | 1921.12 | 20 | 14.89 | 2954 | 880 | 2.93 / 65.18 | 5 | 72 |
4 | 13 | 1292.28 | 20 | 14.95 | 2116 | 633 | 3.56 / 65.81 | 5 | 83 |
5 | 13 | 865.56 | 20 | 15.02 | 1551 | 466 | 4.02 / 66.27 | 5 | 88 |
6 | 13 | 179.04 | 20 | 15.18 | 609 | 185 | 4.21 / 66.46 | 6 | 83 |
7 | 13 | 44.76 | 20 | 15.21 | 401 | 122 | 4.33 / 66.58 | 6 | 85 |
8 | 8 | -0.04 | 233 | 15.17 | 321 | 1135 | 5.47 / 67.72 | 6 | 135 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 34 | 15.18 | 461 | 238 | 0.24 / 57.05 | 6 | 18 |
2 | 7 | 2003.64 | 40 | 14.92 | 3041 | 1815 | 2.05 / 58.87 | 18 | 66 |
3 | 13 | 1908.04 | 20 | 14.89 | 2948 | 878 | 2.93 / 59.75 | 5 | 72 |
4 | 13 | 1365.24 | 20 | 14.94 | 2223 | 664 | 3.59 / 60.41 | 5 | 83 |
5 | 13 | 810.64 | 20 | 15.04 | 1475 | 444 | 4.04 / 60.85 | 5 | 89 |
6 | 13 | 67.72 | 20 | 15.22 | 451 | 137 | 4.18 / 60.99 | 6 | 85 |
7 | 13 | 37.76 | 20 | 15.22 | 401 | 122 | 4.30 / 61.11 | 6 | 84 |
8 | 8 | 0.08 | 229 | 15.18 | 327 | 1137 | 5.43 / 62.25 | 6 | 135 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 33 | 15.18 | 453 | 227 | 0.23 / 51.60 | 6 | 19 |
2 | 7 | 2006.36 | 40 | 14.93 | 3048 | 1820 | 2.05 / 53.42 | 19 | 66 |
3 | 13 | 1921.48 | 20 | 14.90 | 2956 | 881 | 2.93 / 54.30 | 5 | 72 |
4 | 13 | 1488.56 | 20 | 14.92 | 2391 | 713 | 3.64 / 55.01 | 5 | 81 |
5 | 13 | 715.64 | 20 | 15.06 | 1344 | 405 | 4.05 / 55.42 | 5 | 89 |
6 | 13 | 81.60 | 20 | 15.22 | 459 | 140 | 4.19 / 55.56 | 6 | 85 |
7 | 13 | 46.08 | 20 | 15.22 | 408 | 124 | 4.31 / 55.68 | 6 | 84 |
8 | 8 | 0.08 | 231 | 15.18 | 324 | 1136 | 5.45 / 56.82 | 6 | 135 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 33 | 15.19 | 461 | 231 | 0.23 / 46.12 | 6 | 18 |
2 | 7 | 2007.92 | 40 | 14.93 | 3052 | 1823 | 2.05 / 47.95 | 18 | 66 |
3 | 13 | 1910.56 | 20 | 14.91 | 2928 | 873 | 2.93 / 48.82 | 5 | 72 |
4 | 13 | 1380.28 | 20 | 14.95 | 2240 | 670 | 3.60 / 49.49 | 5 | 83 |
5 | 13 | 846.72 | 20 | 15.03 | 1517 | 456 | 4.05 / 49.94 | 5 | 90 |
6 | 13 | 159.00 | 20 | 15.20 | 573 | 174 | 4.23 / 50.12 | 6 | 88 |
7 | 13 | 30.88 | 20 | 15.23 | 377 | 115 | 4.34 / 50.23 | 6 | 85 |
8 | 8 | 0.04 | 233 | 15.19 | 321 | 1136 | 5.48 / 51.37 | 6 | 129 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 33 | 15.19 | 447 | 224 | 0.22 / 40.48 | 6 | 19 |
2 | 7 | 2011.64 | 40 | 14.93 | 3066 | 1831 | 2.06 / 42.31 | 19 | 66 |
3 | 13 | 1922.56 | 20 | 14.91 | 2971 | 886 | 2.94 / 43.20 | 5 | 73 |
4 | 13 | 1475.96 | 20 | 14.93 | 2377 | 710 | 3.65 / 43.91 | 5 | 82 |
5 | 13 | 1027.08 | 20 | 14.99 | 1769 | 530 | 4.18 / 44.44 | 5 | 89 |
6 | 13 | 124.12 | 20 | 15.22 | 530 | 161 | 4.34 / 44.60 | 6 | 88 |
7 | 13 | 32.16 | 20 | 15.23 | 387 | 118 | 4.46 / 44.72 | 6 | 85 |
8 | 8 | 0.00 | 238 | 15.19 | 325 | 1175 | 5.64 / 45.89 | 6 | 147 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 33 | 15.19 | 448 | 225 | 0.22 / 34.89 | 6 | 20 |
2 | 7 | 2009.84 | 41 | 14.94 | 3055 | 1871 | 2.10 / 36.76 | 20 | 69 |
3 | 13 | 1920.04 | 20 | 14.90 | 2969 | 885 | 2.98 / 37.65 | 5 | 74 |
4 | 13 | 1268.44 | 20 | 14.98 | 2093 | 627 | 3.61 / 38.27 | 5 | 86 |
5 | 13 | 841.76 | 20 | 15.04 | 1508 | 454 | 4.06 / 38.73 | 5 | 88 |
6 | 13 | 371.92 | 20 | 15.14 | 883 | 267 | 4.33 / 38.99 | 6 | 92 |
7 | 13 | 25.32 | 20 | 15.23 | 371 | 113 | 4.44 / 39.11 | 6 | 88 |
8 | 8 | 0.04 | 234 | 15.19 | 323 | 1148 | 5.59 / 40.26 | 6 | 131 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 33 | 15.20 | 442 | 222 | 0.22 / 29.16 | 6 | 22 |
2 | 7 | 2010.40 | 40 | 14.93 | 3063 | 1829 | 2.05 / 30.99 | 8 | 69 |
3 | 13 | 1933.04 | 20 | 14.91 | 2972 | 886 | 2.94 / 31.87 | 5 | 73 |
4 | 13 | 1837.40 | 20 | 14.86 | 2851 | 847 | 3.78 / 32.72 | 5 | 77 |
5 | 13 | 848.56 | 20 | 15.05 | 1524 | 459 | 4.24 / 33.18 | 5 | 88 |
6 | 13 | 170.60 | 20 | 15.21 | 595 | 181 | 4.42 / 33.36 | 6 | 86 |
7 | 13 | 35.96 | 20 | 15.24 | 399 | 122 | 4.55 / 33.48 | 6 | 88 |
8 | 8 | 0.16 | 238 | 15.19 | 328 | 1186 | 5.73 / 34.67 | 6 | 137 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 32 | 15.21 | 453 | 220 | 0.22 / 23.61 | 6 | 22 |
2 | 10 | 1001.72 | 3 | 15.23 | 1757 | 80 | 0.30 / 23.69 | 6 | 63 |
3 | 3 | 966.56 | -1 | 15.53 | 0 | 0 | 0.08 / 23.69 | 6 | 63 |
4 | 7 | 2012.88 | 40 | 14.95 | 3065 | 1833 | 2.13 / 25.52 | 63 | 68 |
5 | 13 | 1920.08 | 20 | 14.92 | 2968 | 886 | 3.02 / 26.41 | 5 | 73 |
6 | 13 | 1176.60 | 20 | 15.01 | 1979 | 594 | 3.61 / 27.00 | 5 | 83 |
7 | 13 | 853.00 | 20 | 15.05 | 1524 | 459 | 4.07 / 27.46 | 5 | 87 |
8 | 13 | 175.48 | 20 | 15.21 | 606 | 184 | 4.26 / 27.64 | 6 | 87 |
9 | 13 | 33.88 | 20 | 15.24 | 386 | 118 | 4.37 / 27.76 | 6 | 88 |
10 | 8 | 0.04 | 240 | 15.20 | 322 | 1175 | 5.55 / 28.93 | 6 | 130 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 31 | 15.23 | 438 | 207 | 0.21 / 18.14 | 6 | 22 |
2 | 10 | 1027.32 | 3 | 15.21 | 1799 | 82 | 0.29 / 18.23 | 6 | 66 |
3 | 3 | 950.40 | -1 | 15.54 | 0 | 0 | 0.08 / 18.23 | 6 | 66 |
4 | 7 | 2006.84 | 41 | 14.95 | 3043 | 1865 | 2.15 / 20.09 | 66 | 69 |
5 | 13 | 1924.28 | 20 | 14.92 | 2951 | 881 | 3.03 / 20.97 | 5 | 72 |
6 | 13 | 1288.16 | 20 | 14.99 | 2133 | 639 | 3.67 / 21.61 | 5 | 83 |
7 | 13 | 850.08 | 20 | 15.05 | 1517 | 457 | 4.13 / 22.07 | 5 | 88 |
8 | 13 | 84.96 | 20 | 15.24 | 463 | 141 | 4.27 / 22.21 | 6 | 84 |
9 | 8 | 0.04 | 248 | 15.22 | 312 | 1178 | 5.45 / 23.39 | 6 | 133 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 32 | 15.23 | 426 | 208 | 0.21 / 13.59 | 6 | 22 |
2 | 7 | 1519.68 | 40 | 15.10 | 2409 | 1455 | 1.66 / 15.04 | 22 | 73 |
3 | 13 | 1442.96 | 20 | 15.08 | 2314 | 698 | 2.36 / 15.74 | 5 | 76 |
4 | 13 | 1250.96 | 20 | 15.07 | 2062 | 621 | 2.98 / 16.36 | 6 | 80 |
5 | 13 | 414.96 | 20 | 15.21 | 931 | 283 | 3.27 / 16.64 | 6 | 88 |
6 | 13 | 46.52 | 20 | 15.29 | 393 | 120 | 3.39 / 16.76 | 6 | 84 |
7 | 8 | 0.12 | 248 | 15.25 | 310 | 1172 | 4.56 / 17.94 | 6 | 129 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 31 | 15.23 | 414 | 195 | 0.20 / 8.99 | 6 | 21 |
2 | 3 | 1020.76 | 1 | 15.28 | 1820 | 28 | 0.22 / 9.02 | 6 | 9 |
3 | 7 | 1515.12 | 40 | 15.10 | 2394 | 1446 | 1.67 / 10.47 | 9 | 71 |
4 | 13 | 1442.56 | 20 | 15.08 | 2317 | 699 | 2.37 / 11.17 | 5 | 74 |
5 | 13 | 1237.88 | 20 | 15.07 | 2030 | 612 | 2.98 / 11.78 | 5 | 79 |
6 | 13 | 543.84 | 20 | 15.18 | 1096 | 333 | 3.31 / 12.11 | 6 | 88 |
7 | 13 | 50.76 | 20 | 15.29 | 396 | 121 | 3.43 / 12.23 | 6 | 85 |
8 | 8 | -0.04 | 248 | 15.25 | 303 | 1146 | 4.58 / 13.38 | 6 | 131 |
Average= | 3.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 31 | 15.27 | 427 | 202 | 0.20 / 4.46 | 6 | 23 |
2 | 3 | 1019.60 | 1 | 15.29 | 1817 | 28 | 0.23 / 4.49 | 6 | 11 |
3 | 7 | 1507.80 | 41 | 15.10 | 2377 | 1472 | 1.70 / 5.96 | 11 | 72 |
4 | 13 | 1424.48 | 20 | 15.09 | 2284 | 689 | 2.39 / 6.65 | 5 | 76 |
5 | 13 | 1242.92 | 20 | 15.07 | 2040 | 615 | 3.01 / 7.26 | 5 | 80 |
6 | 13 | 463.24 | 20 | 15.19 | 985 | 299 | 3.30 / 7.56 | 6 | 89 |
7 | 13 | 39.68 | 20 | 15.29 | 372 | 114 | 3.42 / 7.68 | 6 | 85 |
8 | 8 | 0.20 | 246 | 15.25 | 299 | 1122 | 4.54 / 8.80 | 6 | 136 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 31 | 15.44 | 390 | 187 | 0.19 / 1.68 | 6 | 16 |
2 | 7 | 1010.24 | 41 | 15.20 | 1709 | 1065 | 1.25 / 2.74 | 16 | 79 |
3 | 13 | 477.40 | 20 | 15.27 | 993 | 303 | 1.55 / 3.04 | 6 | 86 |
4 | 13 | 62.64 | 20 | 15.34 | 409 | 125 | 1.68 / 3.17 | 6 | 84 |
5 | 8 | 0.20 | 242 | 15.30 | 294 | 1089 | 2.77 / 4.26 | 6 | 129 |
Average= | 2.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 54.68 | 30 | 15.58 | 336 | 157 | 0.16 / 0.16 | 6 | 24 |
2 | 7 | 63.68 | 40 | 15.57 | 337 | 210 | 0.37 / 0.37 | 24 | 27 |
3 | 13 | 48.32 | 20 | 15.56 | 314 | 98 | 0.46 / 0.46 | 6 | 28 |
4 | 13 | 27.08 | 20 | 15.55 | 281 | 87 | 0.55 / 0.55 | 6 | 31 |
5 | 8 | 0.04 | 255 | 15.51 | 237 | 937 | 1.49 / 1.49 | 6 | 138 |
Average= | 1.49 (KJ/cycle) |