SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 25 | 15.01 | 426 | 160 | 0.16 / 1480.46 | 6 | 8 |
2 | 7 | 2011.84 | 40 | 14.43 | 3097 | 1788 | 1.95 / 1482.24 | 8 | 41 |
3 | 13 | 1985.20 | 20 | 14.41 | 3060 | 882 | 2.83 / 1483.12 | 5 | 43 |
4 | 13 | 1676.00 | 20 | 14.42 | 2648 | 764 | 3.59 / 1483.89 | 5 | 50 |
5 | 13 | 1099.00 | 20 | 14.58 | 1871 | 546 | 4.14 / 1484.43 | 5 | 61 |
6 | 13 | 511.28 | 20 | 14.80 | 1055 | 312 | 4.45 / 1484.75 | 5 | 64 |
7 | 13 | 128.72 | 20 | 14.96 | 496 | 148 | 4.60 / 1484.89 | 6 | 54 |
8 | 13 | 13.00 | 20 | 15.00 | 315 | 94 | 4.69 / 1484.99 | 6 | 43 |
9 | 8 | 0.04 | 233 | 14.96 | 285 | 993 | 5.69 / 1485.98 | 6 | 214 |
Average= | 8.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 25 | 15.00 | 432 | 162 | 0.16 / 1474.80 | 6 | 7 |
2 | 7 | 2009.72 | 40 | 14.44 | 3101 | 1791 | 1.95 / 1476.59 | 7 | 42 |
3 | 13 | 1981.52 | 20 | 14.41 | 3057 | 881 | 2.83 / 1477.47 | 5 | 45 |
4 | 13 | 1670.84 | 20 | 14.43 | 2655 | 766 | 3.60 / 1478.24 | 5 | 50 |
5 | 13 | 1081.64 | 20 | 14.59 | 1849 | 540 | 4.14 / 1478.78 | 5 | 60 |
6 | 13 | 453.40 | 20 | 14.82 | 986 | 292 | 4.43 / 1479.07 | 5 | 60 |
7 | 13 | 115.48 | 20 | 14.97 | 478 | 143 | 4.58 / 1479.21 | 6 | 47 |
8 | 8 | 0.20 | 253 | 14.97 | 286 | 1083 | 5.66 / 1480.30 | 6 | -99 |
Average= | 8.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 25 | 14.99 | 431 | 162 | 0.16 / 1469.10 | 6 | 9 |
2 | 7 | 2012.60 | 40 | 14.44 | 3088 | 1784 | 1.95 / 1470.88 | 9 | 42 |
3 | 13 | 1985.60 | 20 | 14.41 | 3064 | 883 | 2.83 / 1471.77 | 5 | 43 |
4 | 13 | 1779.00 | 20 | 14.40 | 2787 | 803 | 3.63 / 1472.57 | 5 | 49 |
5 | 13 | 1057.56 | 20 | 14.61 | 1819 | 532 | 4.16 / 1473.10 | 5 | 62 |
6 | 13 | 445.44 | 20 | 14.82 | 974 | 289 | 4.45 / 1473.39 | 5 | 64 |
7 | 13 | 101.56 | 20 | 14.97 | 464 | 139 | 4.59 / 1473.53 | 6 | 50 |
8 | 8 | 0.24 | 253 | 14.96 | 293 | 1109 | 5.70 / 1474.64 | 6 | -99 |
Average= | 8.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 25 | 15.00 | 415 | 156 | 0.16 / 1463.36 | 6 | 8 |
2 | 7 | 2012.08 | 40 | 14.44 | 3104 | 1793 | 1.95 / 1465.15 | 8 | 43 |
3 | 13 | 1985.04 | 20 | 14.42 | 3055 | 881 | 2.83 / 1466.03 | 5 | 43 |
4 | 13 | 1742.36 | 20 | 14.41 | 2739 | 789 | 3.62 / 1466.82 | 5 | 46 |
5 | 13 | 1072.72 | 20 | 14.60 | 1841 | 538 | 4.16 / 1467.36 | 5 | 60 |
6 | 13 | 526.72 | 20 | 14.79 | 1085 | 321 | 4.48 / 1467.68 | 5 | 62 |
7 | 13 | 93.88 | 20 | 14.97 | 456 | 137 | 4.61 / 1467.82 | 6 | 52 |
8 | 8 | 0.08 | 253 | 14.95 | 296 | 1120 | 5.73 / 1468.94 | 6 | -99 |
Average= | 8.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 25 | 14.99 | 412 | 154 | 0.15 / 1457.71 | 6 | 6 |
2 | 7 | 2010.48 | 41 | 14.43 | 3087 | 1826 | 1.98 / 1459.54 | 6 | 42 |
3 | 13 | 1982.80 | 20 | 14.41 | 3062 | 882 | 2.86 / 1460.42 | 5 | 46 |
4 | 13 | 1638.60 | 20 | 14.44 | 2593 | 749 | 3.61 / 1461.17 | 5 | 54 |
5 | 13 | 1058.52 | 20 | 14.60 | 1814 | 530 | 4.14 / 1461.70 | 5 | 58 |
6 | 13 | 464.04 | 20 | 14.81 | 994 | 294 | 4.44 / 1461.99 | 5 | 66 |
7 | 13 | 81.36 | 20 | 14.97 | 426 | 128 | 4.56 / 1462.12 | 6 | 57 |
8 | 8 | 0.08 | 250 | 14.96 | 290 | 1085 | 5.65 / 1463.20 | 6 | 144 |
Average= | 8.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 25 | 14.98 | 415 | 155 | 0.16 / 1452.00 | 6 | 7 |
2 | 7 | 2009.92 | 40 | 14.44 | 3089 | 1784 | 1.94 / 1453.79 | 7 | 40 |
3 | 13 | 1981.08 | 20 | 14.42 | 3063 | 883 | 2.82 / 1454.67 | 5 | 44 |
4 | 13 | 1731.52 | 20 | 14.42 | 2719 | 784 | 3.61 / 1455.45 | 5 | 49 |
5 | 13 | 1058.84 | 20 | 14.60 | 1819 | 531 | 4.14 / 1455.98 | 5 | 61 |
6 | 13 | 572.00 | 20 | 14.77 | 1142 | 337 | 4.48 / 1456.32 | 5 | 66 |
7 | 13 | 103.72 | 20 | 14.96 | 461 | 138 | 4.61 / 1456.46 | 6 | 51 |
8 | 8 | 0.24 | 253 | 14.95 | 290 | 1097 | 5.71 / 1457.56 | 6 | 207 |
Average= | 8.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 25 | 15.00 | 410 | 154 | 0.15 / 1446.23 | 6 | 7 |
2 | 7 | 2010.88 | 40 | 14.43 | 3093 | 1785 | 1.94 / 1448.01 | 7 | 41 |
3 | 13 | 1983.52 | 20 | 14.42 | 3054 | 881 | 2.82 / 1448.89 | 5 | 45 |
4 | 13 | 1668.36 | 20 | 14.43 | 2635 | 760 | 3.58 / 1449.65 | 5 | 50 |
5 | 13 | 1264.12 | 20 | 14.52 | 2100 | 610 | 4.19 / 1450.26 | 5 | 58 |
6 | 13 | 536.16 | 20 | 14.78 | 1097 | 324 | 4.51 / 1450.59 | 5 | 67 |
7 | 13 | 128.24 | 20 | 14.95 | 507 | 152 | 4.67 / 1450.74 | 5 | 53 |
8 | 8 | 0.16 | 253 | 14.95 | 293 | 1108 | 5.77 / 1451.85 | 6 | 209 |
Average= | 8.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 25 | 15.00 | 414 | 155 | 0.16 / 1440.62 | 6 | 6 |
2 | 7 | 2009.56 | 40 | 14.44 | 3091 | 1785 | 1.94 / 1442.41 | 6 | 41 |
3 | 13 | 1982.68 | 20 | 14.42 | 3057 | 882 | 2.82 / 1443.29 | 5 | 43 |
4 | 13 | 1641.80 | 20 | 14.44 | 2599 | 751 | 3.57 / 1444.04 | 5 | 48 |
5 | 13 | 1056.88 | 20 | 14.60 | 1816 | 530 | 4.10 / 1444.57 | 5 | 63 |
6 | 13 | 439.24 | 20 | 14.82 | 958 | 284 | 4.39 / 1444.85 | 5 | 62 |
7 | 13 | 98.88 | 20 | 14.96 | 451 | 135 | 4.52 / 1444.99 | 6 | 50 |
8 | 8 | 0.08 | 253 | 14.95 | 286 | 1082 | 5.60 / 1446.07 | 6 | 187 |
Average= | 8.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 25 | 15.00 | 413 | 155 | 0.15 / 1434.76 | 6 | 6 |
2 | 7 | 2008.76 | 40 | 14.43 | 3092 | 1785 | 1.94 / 1436.54 | 6 | 42 |
3 | 13 | 1983.60 | 20 | 14.41 | 3051 | 879 | 2.82 / 1437.42 | 5 | 43 |
4 | 13 | 1783.00 | 20 | 14.40 | 2789 | 803 | 3.62 / 1438.22 | 5 | 45 |
5 | 13 | 1361.80 | 20 | 14.49 | 2229 | 646 | 4.27 / 1438.87 | 5 | 58 |
6 | 13 | 616.76 | 20 | 14.75 | 1206 | 356 | 4.62 / 1439.22 | 5 | 64 |
7 | 13 | 70.52 | 20 | 14.97 | 418 | 125 | 4.75 / 1439.35 | 6 | 52 |
8 | 13 | 23.40 | 20 | 14.98 | 340 | 102 | 4.85 / 1439.45 | 6 | 45 |
9 | 8 | 0.12 | 233 | 14.94 | 292 | 1016 | 5.87 / 1440.47 | 6 | 152 |
Average= | 8.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 25 | 15.00 | 419 | 157 | 0.16 / 1428.90 | 6 | 8 |
2 | 7 | 2004.64 | 40 | 14.43 | 3089 | 1783 | 1.94 / 1430.68 | 8 | 42 |
3 | 13 | 1979.52 | 20 | 14.41 | 3048 | 878 | 2.82 / 1431.56 | 5 | 41 |
4 | 13 | 1881.16 | 20 | 14.37 | 2920 | 839 | 3.66 / 1432.40 | 5 | 49 |
5 | 13 | 1046.36 | 20 | 14.61 | 1803 | 527 | 4.18 / 1432.93 | 5 | 62 |
6 | 13 | 810.16 | 20 | 14.67 | 1475 | 433 | 4.62 / 1433.36 | 5 | 63 |
7 | 13 | 90.40 | 20 | 14.97 | 436 | 131 | 4.75 / 1433.49 | 6 | 48 |
8 | 13 | 61.60 | 20 | 14.98 | 391 | 117 | 4.87 / 1433.61 | 6 | 52 |
9 | 8 | 0.08 | 233 | 14.95 | 285 | 993 | 5.86 / 1434.60 | 6 | 199 |
Average= | 8.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 25 | 14.98 | 420 | 157 | 0.16 / 1423.26 | 6 | 9 |
2 | 7 | 2009.28 | 40 | 14.44 | 3094 | 1787 | 1.94 / 1425.04 | 9 | 41 |
3 | 13 | 1980.80 | 20 | 14.43 | 3048 | 880 | 2.82 / 1425.92 | 5 | 45 |
4 | 13 | 1631.84 | 20 | 14.45 | 2593 | 749 | 3.57 / 1426.67 | 5 | 48 |
5 | 13 | 1048.76 | 20 | 14.61 | 1799 | 526 | 4.10 / 1427.20 | 5 | 59 |
6 | 13 | 465.12 | 20 | 14.82 | 989 | 293 | 4.39 / 1427.49 | 5 | 59 |
7 | 13 | 154.68 | 20 | 14.94 | 532 | 159 | 4.55 / 1427.65 | 6 | 46 |
8 | 13 | 49.32 | 20 | 14.98 | 365 | 109 | 4.66 / 1427.76 | 6 | 37 |
9 | 8 | 0.20 | 233 | 14.96 | 282 | 983 | 5.64 / 1428.74 | 6 | -99 |
Average= | 8.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 25 | 14.98 | 410 | 154 | 0.15 / 1417.60 | 6 | 6 |
2 | 7 | 2004.84 | 41 | 14.45 | 3075 | 1822 | 1.98 / 1419.43 | 6 | 42 |
3 | 13 | 1977.52 | 20 | 14.42 | 3043 | 878 | 2.85 / 1420.30 | 5 | 43 |
4 | 13 | 1625.24 | 20 | 14.44 | 2577 | 744 | 3.60 / 1421.05 | 5 | 51 |
5 | 13 | 1010.36 | 20 | 14.61 | 1756 | 513 | 4.11 / 1421.56 | 5 | 62 |
6 | 13 | 502.84 | 20 | 14.79 | 1041 | 308 | 4.42 / 1421.87 | 5 | 64 |
7 | 13 | 64.04 | 20 | 14.97 | 409 | 122 | 4.54 / 1421.99 | 6 | 51 |
8 | 13 | 18.48 | 20 | 14.98 | 337 | 101 | 4.64 / 1422.09 | 6 | 50 |
9 | 8 | 0.32 | 231 | 14.94 | 292 | 1008 | 5.65 / 1423.10 | 6 | 162 |
Average= | 8.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 25 | 14.98 | 414 | 155 | 0.16 / 1411.67 | 6 | 7 |
2 | 7 | 2016.52 | 40 | 14.44 | 3097 | 1789 | 1.94 / 1413.46 | 7 | 40 |
3 | 13 | 1989.12 | 20 | 14.41 | 3065 | 883 | 2.83 / 1414.34 | 5 | 46 |
4 | 13 | 1816.76 | 20 | 14.39 | 2836 | 816 | 3.64 / 1415.15 | 5 | 47 |
5 | 13 | 1445.84 | 20 | 14.47 | 2342 | 678 | 4.32 / 1415.83 | 5 | 54 |
6 | 13 | 622.80 | 20 | 14.75 | 1217 | 359 | 4.68 / 1416.19 | 5 | 67 |
7 | 13 | 63.00 | 20 | 14.96 | 407 | 122 | 4.80 / 1416.31 | 6 | 58 |
8 | 13 | 15.32 | 20 | 14.97 | 333 | 100 | 4.90 / 1416.41 | 6 | 56 |
9 | 8 | 0.04 | 233 | 14.93 | 298 | 1037 | 5.94 / 1417.45 | 6 | -99 |
Average= | 8.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 25 | 14.97 | 417 | 156 | 0.16 / 1405.98 | 6 | 7 |
2 | 7 | 2018.52 | 41 | 14.44 | 3109 | 1841 | 2.00 / 1407.82 | 7 | 42 |
3 | 13 | 1993.56 | 20 | 14.42 | 3079 | 888 | 2.88 / 1408.71 | 5 | 45 |
4 | 13 | 1726.52 | 20 | 14.42 | 2720 | 784 | 3.67 / 1409.49 | 5 | 50 |
5 | 13 | 947.64 | 20 | 14.63 | 1667 | 488 | 4.16 / 1409.98 | 5 | 62 |
6 | 13 | 512.16 | 20 | 14.78 | 1061 | 314 | 4.47 / 1410.29 | 5 | 67 |
7 | 13 | 40.52 | 20 | 14.97 | 376 | 113 | 4.58 / 1410.41 | 6 | 52 |
8 | 8 | 0.08 | 250 | 14.93 | 296 | 1105 | 5.69 / 1411.51 | 6 | 181 |
Average= | 8.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 25 | 14.97 | 430 | 161 | 0.16 / 1400.29 | 6 | 6 |
2 | 7 | 2011.76 | 40 | 14.45 | 3096 | 1789 | 1.95 / 1402.08 | 6 | 44 |
3 | 13 | 1982.52 | 20 | 14.43 | 3054 | 881 | 2.83 / 1402.96 | 5 | 45 |
4 | 13 | 1702.00 | 20 | 14.43 | 2683 | 774 | 3.61 / 1403.73 | 5 | 51 |
5 | 13 | 1060.68 | 20 | 14.59 | 1827 | 533 | 4.14 / 1404.27 | 5 | 62 |
6 | 13 | 512.16 | 20 | 14.78 | 1067 | 315 | 4.45 / 1404.58 | 5 | 69 |
7 | 13 | 43.40 | 20 | 14.96 | 382 | 114 | 4.57 / 1404.70 | 5 | 54 |
8 | 8 | 0.12 | 250 | 14.92 | 302 | 1126 | 5.70 / 1405.82 | 6 | 168 |
Average= | 8.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 25 | 14.97 | 423 | 158 | 0.16 / 1394.59 | 6 | 6 |
2 | 7 | 2014.20 | 40 | 14.45 | 3091 | 1787 | 1.94 / 1396.37 | 6 | 40 |
3 | 13 | 1986.84 | 20 | 14.43 | 3061 | 883 | 2.83 / 1397.26 | 5 | 42 |
4 | 13 | 1709.16 | 20 | 14.43 | 2692 | 777 | 3.61 / 1398.03 | 5 | 48 |
5 | 13 | 1118.76 | 20 | 14.58 | 1901 | 554 | 4.16 / 1398.59 | 5 | 60 |
6 | 13 | 460.80 | 20 | 14.79 | 991 | 293 | 4.45 / 1398.88 | 5 | 66 |
7 | 13 | 35.56 | 20 | 14.96 | 374 | 112 | 4.56 / 1398.99 | 5 | 56 |
8 | 8 | -0.04 | 250 | 14.92 | 304 | 1134 | 5.70 / 1400.13 | 6 | 173 |
Average= | 8.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 25 | 14.98 | 420 | 157 | 0.16 / 1388.86 | 6 | 9 |
2 | 7 | 2006.12 | 40 | 14.44 | 3091 | 1785 | 1.94 / 1390.65 | 9 | 38 |
3 | 13 | 1978.04 | 20 | 14.42 | 3045 | 878 | 2.82 / 1391.53 | 5 | 46 |
4 | 13 | 1625.36 | 20 | 14.44 | 2584 | 746 | 3.57 / 1392.27 | 5 | 51 |
5 | 13 | 1209.32 | 20 | 14.53 | 2031 | 590 | 4.16 / 1392.86 | 5 | 61 |
6 | 13 | 533.68 | 20 | 14.76 | 1093 | 323 | 4.48 / 1393.18 | 5 | 65 |
7 | 13 | 28.32 | 20 | 14.95 | 361 | 108 | 4.59 / 1393.29 | 5 | 61 |
8 | 8 | -0.08 | 250 | 14.91 | 305 | 1137 | 5.72 / 1394.43 | 6 | 218 |
Average= | 8.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 25 | 15.00 | 419 | 157 | 0.16 / 1383.15 | 6 | 8 |
2 | 7 | 2017.68 | 40 | 14.43 | 3105 | 1792 | 1.95 / 1384.94 | 8 | 42 |
3 | 13 | 1990.88 | 20 | 14.40 | 3061 | 882 | 2.83 / 1385.82 | 5 | 44 |
4 | 13 | 1678.64 | 20 | 14.42 | 2653 | 765 | 3.60 / 1386.59 | 5 | 50 |
5 | 13 | 1089.56 | 20 | 14.57 | 1856 | 541 | 4.14 / 1387.13 | 5 | 59 |
6 | 13 | 571.88 | 20 | 14.75 | 1144 | 337 | 4.47 / 1387.46 | 5 | 69 |
7 | 13 | 58.20 | 20 | 14.96 | 396 | 118 | 4.59 / 1387.58 | 6 | 50 |
8 | 13 | 33.28 | 20 | 14.96 | 356 | 107 | 4.70 / 1387.69 | 6 | 46 |
9 | 8 | 0.08 | 233 | 14.93 | 292 | 1016 | 5.72 / 1388.70 | 6 | -99 |
Average= | 8.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 25 | 15.00 | 411 | 154 | 0.15 / 1377.47 | 6 | 6 |
2 | 7 | 2016.16 | 41 | 14.43 | 3091 | 1829 | 1.98 / 1379.29 | 6 | 41 |
3 | 13 | 1988.84 | 20 | 14.41 | 3055 | 880 | 2.86 / 1380.17 | 5 | 42 |
4 | 13 | 1709.08 | 20 | 14.42 | 2694 | 777 | 3.64 / 1380.95 | 5 | 50 |
5 | 13 | 1050.84 | 20 | 14.59 | 1809 | 528 | 4.17 / 1381.48 | 5 | 60 |
6 | 13 | 477.88 | 20 | 14.81 | 1006 | 298 | 4.47 / 1381.78 | 5 | 58 |
7 | 13 | 128.64 | 20 | 14.95 | 488 | 146 | 4.61 / 1381.92 | 6 | 45 |
8 | 13 | 14.64 | 20 | 14.99 | 315 | 94 | 4.71 / 1382.02 | 6 | 38 |
9 | 8 | 0.08 | 233 | 14.95 | 279 | 972 | 5.68 / 1382.99 | 6 | -99 |
Average= | 8.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 25 | 15.01 | 413 | 155 | 0.15 / 1371.86 | 6 | 6 |
2 | 7 | 2008.28 | 40 | 14.43 | 3088 | 1782 | 1.94 / 1373.64 | 6 | 41 |
3 | 13 | 1982.52 | 20 | 14.41 | 3063 | 883 | 2.82 / 1374.53 | 5 | 45 |
4 | 13 | 1711.04 | 20 | 14.41 | 2699 | 778 | 3.60 / 1375.31 | 5 | 48 |
5 | 13 | 1041.12 | 20 | 14.60 | 1793 | 524 | 4.12 / 1375.83 | 5 | 61 |
6 | 13 | 358.32 | 20 | 14.86 | 826 | 245 | 4.37 / 1376.07 | 5 | 54 |
7 | 13 | 137.68 | 20 | 14.95 | 500 | 149 | 4.52 / 1376.22 | 6 | 44 |
8 | 13 | 66.56 | 20 | 14.97 | 387 | 116 | 4.63 / 1376.34 | 6 | 42 |
9 | 8 | 0.04 | 233 | 14.95 | 279 | 972 | 5.60 / 1377.31 | 6 | -99 |
Average= | 8.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 25 | 14.99 | 417 | 156 | 0.16 / 1366.04 | 6 | 7 |
2 | 7 | 2012.28 | 40 | 14.44 | 3097 | 1789 | 1.95 / 1367.83 | 7 | 40 |
3 | 13 | 1985.28 | 20 | 14.42 | 3066 | 884 | 2.83 / 1368.71 | 5 | 45 |
4 | 13 | 1814.08 | 20 | 14.39 | 2836 | 816 | 3.65 / 1369.53 | 5 | 47 |
5 | 13 | 1079.28 | 20 | 14.59 | 1849 | 540 | 4.19 / 1370.07 | 5 | 60 |
6 | 13 | 776.00 | 20 | 14.68 | 1427 | 419 | 4.60 / 1370.49 | 5 | 63 |
7 | 13 | 130.52 | 20 | 14.95 | 491 | 147 | 4.75 / 1370.63 | 6 | 47 |
8 | 13 | 17.88 | 20 | 14.99 | 317 | 95 | 4.85 / 1370.73 | 6 | 39 |
9 | 8 | 0.16 | 235 | 14.96 | 278 | 977 | 5.82 / 1371.71 | 6 | -99 |
Average= | 8.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 25 | 14.99 | 420 | 157 | 0.16 / 1360.26 | 6 | 6 |
2 | 7 | 2004.80 | 40 | 14.45 | 3095 | 1789 | 1.95 / 1362.05 | 6 | 42 |
3 | 13 | 1978.16 | 20 | 14.42 | 3060 | 883 | 2.83 / 1362.93 | 5 | 43 |
4 | 13 | 1527.44 | 20 | 14.46 | 2459 | 711 | 3.54 / 1363.64 | 5 | 53 |
5 | 13 | 1108.52 | 20 | 14.57 | 1887 | 550 | 4.09 / 1364.19 | 5 | 61 |
6 | 13 | 826.76 | 20 | 14.64 | 1509 | 442 | 4.53 / 1364.64 | 5 | 66 |
7 | 13 | 124.40 | 20 | 14.94 | 489 | 146 | 4.68 / 1364.78 | 6 | 45 |
8 | 13 | 54.96 | 20 | 14.96 | 382 | 114 | 4.79 / 1364.90 | 6 | 43 |
9 | 8 | 0.00 | 233 | 14.94 | 284 | 989 | 5.78 / 1365.88 | 6 | 148 |
Average= | 8.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 25 | 14.97 | 421 | 158 | 0.16 / 1354.57 | 6 | 6 |
2 | 7 | 2015.20 | 40 | 14.45 | 3098 | 1791 | 1.95 / 1356.37 | 6 | 41 |
3 | 13 | 1988.40 | 20 | 14.43 | 3080 | 889 | 2.84 / 1357.25 | 5 | 45 |
4 | 13 | 1488.92 | 20 | 14.48 | 2408 | 697 | 3.53 / 1357.95 | 5 | 53 |
5 | 13 | 1054.20 | 20 | 14.59 | 1815 | 530 | 4.06 / 1358.48 | 5 | 59 |
6 | 13 | 652.56 | 20 | 14.71 | 1267 | 373 | 4.44 / 1358.85 | 5 | 67 |
7 | 13 | 127.88 | 20 | 14.93 | 508 | 152 | 4.59 / 1359.01 | 5 | 53 |
8 | 13 | 14.24 | 20 | 14.97 | 326 | 98 | 4.69 / 1359.10 | 6 | 47 |
9 | 8 | 0.00 | 231 | 14.93 | 290 | 1000 | 5.69 / 1360.10 | 6 | 140 |
Average= | 8.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 25 | 14.97 | 415 | 155 | 0.16 / 1348.72 | 6 | 6 |
2 | 7 | 2018.48 | 40 | 14.45 | 3102 | 1793 | 1.95 / 1350.52 | 6 | 41 |
3 | 13 | 1995.68 | 20 | 14.43 | 3069 | 886 | 2.83 / 1351.40 | 5 | 46 |
4 | 13 | 1763.28 | 20 | 14.42 | 2764 | 797 | 3.63 / 1352.20 | 5 | 51 |
5 | 13 | 1314.08 | 20 | 14.50 | 2165 | 628 | 4.26 / 1352.83 | 5 | 58 |
6 | 13 | 462.92 | 20 | 14.79 | 999 | 296 | 4.55 / 1353.12 | 5 | 71 |
7 | 13 | 137.60 | 20 | 14.90 | 532 | 159 | 4.71 / 1353.28 | 5 | 63 |
8 | 13 | 14.52 | 20 | 14.95 | 336 | 100 | 4.81 / 1353.38 | 6 | 55 |
9 | 8 | -0.04 | 231 | 14.91 | 301 | 1037 | 5.85 / 1354.42 | 6 | 193 |
Average= | 8.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 25 | 14.98 | 413 | 155 | 0.15 / 1342.85 | 6 | 8 |
2 | 7 | 2015.52 | 40 | 14.45 | 3103 | 1794 | 1.95 / 1344.65 | 8 | 44 |
3 | 13 | 1988.76 | 20 | 14.42 | 3077 | 887 | 2.84 / 1345.53 | 5 | 42 |
4 | 13 | 1853.68 | 20 | 14.40 | 2881 | 830 | 3.67 / 1346.36 | 5 | 46 |
5 | 13 | 1051.24 | 20 | 14.59 | 1811 | 528 | 4.19 / 1346.89 | 5 | 64 |
6 | 13 | 716.20 | 20 | 14.68 | 1357 | 398 | 4.59 / 1347.29 | 5 | 68 |
7 | 13 | 79.64 | 20 | 14.93 | 444 | 133 | 4.72 / 1347.42 | 5 | 62 |
8 | 13 | 25.36 | 20 | 14.95 | 355 | 106 | 4.83 / 1347.53 | 6 | 54 |
9 | 8 | -0.08 | 231 | 14.91 | 301 | 1037 | 5.87 / 1348.57 | 6 | 178 |
Average= | 8.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 25 | 15.00 | 416 | 156 | 0.16 / 1337.12 | 6 | 6 |
2 | 7 | 2014.52 | 40 | 14.43 | 3099 | 1789 | 1.94 / 1338.91 | 6 | 41 |
3 | 13 | 1988.24 | 20 | 14.40 | 3074 | 885 | 2.83 / 1339.80 | 5 | 44 |
4 | 13 | 1817.48 | 20 | 14.39 | 2831 | 815 | 3.64 / 1340.61 | 5 | 49 |
5 | 13 | 1071.04 | 20 | 14.58 | 1845 | 538 | 4.18 / 1341.15 | 5 | 63 |
6 | 13 | 519.36 | 20 | 14.77 | 1071 | 316 | 4.50 / 1341.47 | 5 | 64 |
7 | 13 | 89.36 | 20 | 14.94 | 442 | 132 | 4.63 / 1341.60 | 6 | 51 |
8 | 13 | 14.04 | 20 | 14.97 | 323 | 97 | 4.73 / 1341.70 | 6 | 48 |
9 | 8 | -0.08 | 231 | 14.93 | 291 | 1004 | 5.73 / 1342.70 | 6 | 169 |
Average= | 8.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 25 | 15.01 | 413 | 155 | 0.15 / 1331.42 | 6 | 7 |
2 | 7 | 2013.48 | 40 | 14.44 | 3096 | 1788 | 1.94 / 1333.20 | 7 | 46 |
3 | 13 | 1986.88 | 20 | 14.42 | 3064 | 884 | 2.83 / 1334.09 | 5 | 49 |
4 | 13 | 1645.20 | 20 | 14.43 | 2617 | 755 | 3.58 / 1334.84 | 5 | 50 |
5 | 13 | 1129.04 | 20 | 14.56 | 1920 | 559 | 4.14 / 1335.40 | 5 | 58 |
6 | 13 | 564.44 | 20 | 14.76 | 1132 | 334 | 4.48 / 1335.74 | 5 | 59 |
7 | 13 | 165.16 | 20 | 14.92 | 546 | 163 | 4.64 / 1335.90 | 6 | 58 |
8 | 13 | 13.40 | 20 | 14.99 | 312 | 94 | 4.73 / 1335.99 | 6 | 38 |
9 | 8 | 0.08 | 233 | 14.95 | 280 | 975 | 5.71 / 1336.97 | 6 | -99 |
Average= | 8.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 25 | 15.01 | 413 | 155 | 0.15 / 1325.79 | 6 | 6 |
2 | 7 | 2013.00 | 41 | 14.43 | 3089 | 1828 | 1.98 / 1327.62 | 6 | 40 |
3 | 13 | 1986.36 | 20 | 14.41 | 3050 | 879 | 2.86 / 1328.50 | 5 | 44 |
4 | 13 | 1674.28 | 20 | 14.42 | 2639 | 761 | 3.62 / 1329.26 | 5 | 50 |
5 | 13 | 1056.96 | 20 | 14.58 | 1822 | 531 | 4.15 / 1329.79 | 5 | 61 |
6 | 13 | 438.84 | 20 | 14.83 | 935 | 277 | 4.43 / 1330.07 | 5 | 52 |
7 | 13 | 168.84 | 20 | 14.94 | 537 | 160 | 4.59 / 1330.23 | 6 | 40 |
8 | 8 | 0.00 | 253 | 14.96 | 273 | 1033 | 5.62 / 1331.26 | 6 | 160 |
Average= | 8.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 25 | 15.01 | 411 | 154 | 0.15 / 1320.09 | 6 | 6 |
2 | 7 | 2012.88 | 40 | 14.44 | 3099 | 1790 | 1.94 / 1321.88 | 6 | 39 |
3 | 13 | 1983.92 | 20 | 14.42 | 3055 | 881 | 2.83 / 1322.77 | 5 | 44 |
4 | 13 | 1708.20 | 20 | 14.41 | 2693 | 776 | 3.60 / 1323.54 | 5 | 51 |
5 | 13 | 1176.36 | 20 | 14.54 | 1979 | 575 | 4.18 / 1324.12 | 5 | 59 |
6 | 13 | 504.28 | 20 | 14.80 | 1036 | 307 | 4.48 / 1324.42 | 5 | 55 |
7 | 13 | 188.84 | 20 | 14.93 | 571 | 171 | 4.65 / 1324.59 | 6 | 44 |
8 | 8 | 0.12 | 255 | 14.96 | 273 | 1041 | 5.70 / 1325.64 | 6 | -99 |
Average= | 8.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 25 | 15.02 | 406 | 152 | 0.15 / 1314.30 | 6 | 6 |
2 | 7 | 2013.04 | 40 | 14.44 | 3102 | 1792 | 1.94 / 1316.09 | 6 | 41 |
3 | 13 | 1985.84 | 20 | 14.42 | 3068 | 885 | 2.83 / 1316.97 | 5 | 43 |
4 | 13 | 1670.96 | 20 | 14.43 | 2652 | 765 | 3.59 / 1317.74 | 5 | 48 |
5 | 13 | 1289.28 | 20 | 14.50 | 2139 | 620 | 4.21 / 1318.36 | 5 | 57 |
6 | 13 | 599.52 | 20 | 14.75 | 1180 | 348 | 4.56 / 1318.71 | 5 | 61 |
7 | 13 | 176.16 | 20 | 14.93 | 553 | 165 | 4.73 / 1318.87 | 6 | 42 |
8 | 13 | 33.00 | 20 | 14.99 | 337 | 101 | 4.83 / 1318.97 | 6 | 34 |
9 | 8 | 0.04 | 235 | 14.96 | 275 | 967 | 5.80 / 1319.94 | 6 | -99 |
Average= | 8.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 25 | 15.02 | 413 | 155 | 0.16 / 1308.62 | 6 | 6 |
2 | 7 | 2015.60 | 41 | 14.43 | 3099 | 1833 | 1.99 / 1310.45 | 6 | 40 |
3 | 13 | 1988.08 | 20 | 14.41 | 3078 | 887 | 2.88 / 1311.34 | 5 | 45 |
4 | 13 | 1673.80 | 20 | 14.42 | 2643 | 762 | 3.64 / 1312.10 | 5 | 51 |
5 | 13 | 1072.80 | 20 | 14.57 | 1843 | 537 | 4.17 / 1312.64 | 5 | 59 |
6 | 13 | 415.84 | 20 | 14.84 | 912 | 271 | 4.45 / 1312.91 | 5 | 54 |
7 | 13 | 189.08 | 20 | 14.93 | 572 | 171 | 4.62 / 1313.08 | 6 | 45 |
8 | 8 | 0.12 | 253 | 14.96 | 281 | 1064 | 5.68 / 1314.14 | 6 | 157 |
Average= | 8.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 25 | 15.02 | 412 | 155 | 0.15 / 1302.87 | 6 | 7 |
2 | 7 | 2010.60 | 40 | 14.44 | 3090 | 1785 | 1.94 / 1304.66 | 7 | 40 |
3 | 13 | 1981.44 | 20 | 14.41 | 3055 | 880 | 2.82 / 1305.54 | 5 | 46 |
4 | 13 | 1658.76 | 20 | 14.43 | 2624 | 757 | 3.58 / 1306.29 | 5 | 50 |
5 | 13 | 1098.76 | 20 | 14.57 | 1879 | 548 | 4.12 / 1306.84 | 5 | 60 |
6 | 13 | 716.44 | 20 | 14.70 | 1348 | 396 | 4.52 / 1307.24 | 5 | 65 |
7 | 13 | 185.84 | 20 | 14.92 | 570 | 170 | 4.69 / 1307.41 | 6 | 45 |
8 | 13 | 21.12 | 20 | 14.99 | 319 | 96 | 4.79 / 1307.50 | 6 | 35 |
9 | 8 | 0.08 | 233 | 14.96 | 276 | 962 | 5.75 / 1308.46 | 6 | 209 |
Average= | 8.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 25 | 15.01 | 411 | 154 | 0.15 / 1297.20 | 6 | 6 |
2 | 7 | 2007.68 | 40 | 14.44 | 3089 | 1784 | 1.94 / 1298.99 | 6 | 42 |
3 | 13 | 1978.16 | 20 | 14.41 | 3058 | 881 | 2.82 / 1299.87 | 5 | 44 |
4 | 13 | 1697.04 | 20 | 14.42 | 2679 | 773 | 3.59 / 1300.64 | 5 | 50 |
5 | 13 | 1147.52 | 20 | 14.55 | 1944 | 566 | 4.16 / 1301.21 | 5 | 59 |
6 | 13 | 509.68 | 20 | 14.79 | 1046 | 309 | 4.47 / 1301.52 | 5 | 56 |
7 | 13 | 166.56 | 20 | 14.94 | 543 | 162 | 4.63 / 1301.68 | 6 | 38 |
8 | 8 | -0.04 | 253 | 14.96 | 274 | 1037 | 5.67 / 1302.72 | 6 | 182 |
Average= | 8.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 25 | 15.00 | 421 | 158 | 0.16 / 1291.54 | 6 | 8 |
2 | 7 | 2013.60 | 40 | 14.44 | 3100 | 1791 | 1.95 / 1293.33 | 8 | 41 |
3 | 13 | 1986.64 | 20 | 14.42 | 3063 | 883 | 2.83 / 1294.21 | 5 | 44 |
4 | 13 | 1779.64 | 20 | 14.40 | 2789 | 803 | 3.64 / 1295.02 | 5 | 47 |
5 | 13 | 1006.80 | 20 | 14.61 | 1753 | 512 | 4.15 / 1295.53 | 5 | 61 |
6 | 13 | 465.20 | 20 | 14.82 | 984 | 292 | 4.44 / 1295.82 | 5 | 56 |
7 | 13 | 159.16 | 20 | 14.94 | 534 | 160 | 4.60 / 1295.98 | 6 | 44 |
8 | 13 | 22.16 | 20 | 14.99 | 322 | 97 | 4.70 / 1296.08 | 6 | 34 |
9 | 8 | 0.08 | 233 | 14.96 | 279 | 973 | 5.67 / 1297.05 | 6 | -99 |
Average= | 9.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 25 | 15.01 | 411 | 154 | 0.15 / 1285.73 | 6 | 6 |
2 | 7 | 2005.88 | 40 | 14.44 | 3078 | 1778 | 1.93 / 1287.51 | 6 | 41 |
3 | 13 | 1976.60 | 20 | 14.42 | 3042 | 877 | 2.81 / 1288.39 | 5 | 47 |
4 | 13 | 1626.52 | 20 | 14.44 | 2583 | 746 | 3.56 / 1289.14 | 5 | 48 |
5 | 13 | 1172.24 | 20 | 14.54 | 1971 | 573 | 4.13 / 1289.71 | 5 | 60 |
6 | 13 | 814.56 | 20 | 14.65 | 1481 | 434 | 4.56 / 1290.14 | 5 | 66 |
7 | 13 | 162.64 | 20 | 14.93 | 536 | 160 | 4.72 / 1290.30 | 6 | 46 |
8 | 8 | 0.04 | 255 | 14.95 | 283 | 1079 | 5.80 / 1291.38 | 6 | -99 |
Average= | 9.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 25 | 15.01 | 420 | 158 | 0.16 / 1279.96 | 6 | 6 |
2 | 7 | 2018.80 | 40 | 14.44 | 3102 | 1792 | 1.95 / 1281.75 | 6 | 40 |
3 | 13 | 1993.44 | 20 | 14.42 | 3072 | 886 | 2.84 / 1282.64 | 5 | 41 |
4 | 13 | 1790.76 | 20 | 14.40 | 2796 | 805 | 3.64 / 1283.44 | 5 | 47 |
5 | 13 | 1151.84 | 20 | 14.55 | 1943 | 565 | 4.21 / 1284.01 | 5 | 58 |
6 | 13 | 591.36 | 20 | 14.76 | 1162 | 343 | 4.55 / 1284.35 | 5 | 63 |
7 | 13 | 186.68 | 20 | 14.92 | 571 | 170 | 4.72 / 1284.52 | 6 | 39 |
8 | 8 | 0.16 | 255 | 14.96 | 278 | 1061 | 5.78 / 1285.58 | 6 | -99 |
Average= | 9.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 25 | 15.00 | 421 | 158 | 0.16 / 1274.25 | 6 | 6 |
2 | 7 | 2014.88 | 40 | 14.45 | 3101 | 1792 | 1.95 / 1276.04 | 6 | 44 |
3 | 13 | 1987.20 | 20 | 14.43 | 3071 | 886 | 2.84 / 1276.93 | 5 | 43 |
4 | 13 | 1739.08 | 20 | 14.42 | 2733 | 788 | 3.62 / 1277.72 | 5 | 50 |
5 | 13 | 1041.92 | 20 | 14.59 | 1795 | 524 | 4.15 / 1278.24 | 5 | 58 |
6 | 13 | 500.40 | 20 | 14.80 | 1035 | 306 | 4.45 / 1278.55 | 5 | 54 |
7 | 13 | 227.56 | 20 | 14.90 | 635 | 189 | 4.64 / 1278.74 | 6 | 49 |
8 | 8 | 0.08 | 255 | 14.96 | 279 | 1064 | 5.71 / 1279.80 | 6 | -99 |
Average= | 9.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 25 | 15.00 | 418 | 157 | 0.16 / 1268.41 | 6 | 7 |
2 | 7 | 2014.32 | 40 | 14.45 | 3097 | 1790 | 1.95 / 1270.20 | 7 | 43 |
3 | 13 | 1987.36 | 20 | 14.42 | 3061 | 883 | 2.83 / 1271.08 | 5 | 42 |
4 | 13 | 1747.84 | 20 | 14.41 | 2746 | 791 | 3.62 / 1271.88 | 5 | 50 |
5 | 13 | 1222.52 | 20 | 14.52 | 2045 | 594 | 4.21 / 1272.47 | 5 | 59 |
6 | 13 | 646.48 | 20 | 14.73 | 1249 | 368 | 4.58 / 1272.84 | 5 | 65 |
7 | 13 | 201.68 | 20 | 14.91 | 597 | 178 | 4.76 / 1273.02 | 6 | 51 |
8 | 13 | 28.12 | 20 | 14.98 | 330 | 99 | 4.86 / 1273.11 | 6 | 36 |
9 | 8 | 0.08 | 236 | 14.95 | 277 | 977 | 5.84 / 1274.09 | 6 | -99 |
Average= | 9.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 25 | 15.00 | 419 | 157 | 0.16 / 1262.75 | 6 | 6 |
2 | 7 | 2012.16 | 40 | 14.45 | 3095 | 1789 | 1.95 / 1264.54 | 6 | 42 |
3 | 13 | 1984.72 | 20 | 14.42 | 3051 | 880 | 2.83 / 1265.42 | 5 | 45 |
4 | 13 | 1677.20 | 20 | 14.42 | 2656 | 766 | 3.59 / 1266.19 | 5 | 51 |
5 | 13 | 1121.20 | 20 | 14.55 | 1908 | 555 | 4.15 / 1266.74 | 5 | 59 |
6 | 13 | 490.48 | 20 | 14.80 | 1023 | 303 | 4.45 / 1267.05 | 5 | 58 |
7 | 13 | 150.84 | 20 | 14.94 | 517 | 154 | 4.60 / 1267.20 | 6 | 43 |
8 | 8 | 0.08 | 255 | 14.96 | 276 | 1053 | 5.66 / 1268.25 | 6 | -99 |
Average= | 9.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 25 | 15.00 | 416 | 156 | 0.16 / 1257.03 | 6 | 7 |
2 | 7 | 2017.04 | 40 | 14.45 | 3100 | 1792 | 1.95 / 1258.82 | 7 | 42 |
3 | 13 | 1990.28 | 20 | 14.42 | 3075 | 887 | 2.83 / 1259.71 | 5 | 43 |
4 | 13 | 1784.08 | 20 | 14.40 | 2788 | 803 | 3.64 / 1260.51 | 5 | 49 |
5 | 13 | 1043.00 | 20 | 14.59 | 1796 | 524 | 4.16 / 1261.04 | 5 | 59 |
6 | 13 | 571.72 | 20 | 14.76 | 1136 | 335 | 4.50 / 1261.37 | 5 | 60 |
7 | 13 | 178.84 | 20 | 14.93 | 559 | 167 | 4.66 / 1261.54 | 6 | 43 |
8 | 8 | 0.00 | 255 | 14.95 | 278 | 1060 | 5.72 / 1262.60 | 6 | -99 |
Average= | 9.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 25 | 15.00 | 419 | 157 | 0.16 / 1251.32 | 6 | 8 |
2 | 7 | 2016.72 | 40 | 14.45 | 3104 | 1794 | 1.95 / 1253.11 | 8 | 40 |
3 | 13 | 1989.52 | 20 | 14.42 | 3072 | 886 | 2.84 / 1254.00 | 5 | 47 |
4 | 13 | 1716.40 | 20 | 14.42 | 2700 | 779 | 3.62 / 1254.78 | 5 | 51 |
5 | 13 | 1087.24 | 20 | 14.57 | 1861 | 542 | 4.16 / 1255.32 | 5 | 59 |
6 | 13 | 558.44 | 20 | 14.77 | 1118 | 330 | 4.49 / 1255.65 | 5 | 59 |
7 | 13 | 167.24 | 20 | 14.93 | 555 | 166 | 4.65 / 1255.82 | 6 | 40 |
8 | 8 | 0.16 | 253 | 14.96 | 279 | 1056 | 5.71 / 1256.87 | 6 | 187 |
Average= | 9.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 25 | 15.00 | 422 | 158 | 0.16 / 1245.69 | 6 | 8 |
2 | 7 | 2009.56 | 40 | 14.46 | 3095 | 1790 | 1.95 / 1247.48 | 8 | 40 |
3 | 13 | 1981.84 | 20 | 14.43 | 3056 | 882 | 2.83 / 1248.36 | 5 | 44 |
4 | 13 | 1593.48 | 20 | 14.45 | 2533 | 732 | 3.56 / 1249.09 | 5 | 52 |
5 | 13 | 1117.88 | 20 | 14.56 | 1900 | 553 | 4.12 / 1249.64 | 5 | 61 |
6 | 13 | 486.64 | 20 | 14.80 | 1020 | 302 | 4.42 / 1249.95 | 5 | 58 |
7 | 13 | 152.48 | 20 | 14.94 | 526 | 157 | 4.57 / 1250.10 | 6 | 44 |
8 | 8 | 0.16 | 253 | 14.96 | 280 | 1060 | 5.63 / 1251.16 | 6 | -99 |
Average= | 9.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 25 | 14.99 | 421 | 158 | 0.16 / 1239.93 | 6 | 10 |
2 | 7 | 2014.20 | 40 | 14.46 | 3096 | 1791 | 1.95 / 1241.72 | 10 | 42 |
3 | 13 | 1987.56 | 20 | 14.43 | 3069 | 886 | 2.83 / 1242.61 | 5 | 44 |
4 | 13 | 1816.68 | 20 | 14.41 | 2832 | 816 | 3.65 / 1243.43 | 5 | 47 |
5 | 13 | 1073.28 | 20 | 14.58 | 1838 | 536 | 4.19 / 1243.96 | 5 | 62 |
6 | 13 | 599.44 | 20 | 14.75 | 1179 | 348 | 4.53 / 1244.31 | 5 | 61 |
7 | 13 | 170.20 | 20 | 14.93 | 546 | 163 | 4.70 / 1244.47 | 6 | 44 |
8 | 8 | 0.08 | 255 | 14.96 | 277 | 1057 | 5.75 / 1245.53 | 6 | -99 |
Average= | 9.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 25 | 14.98 | 426 | 160 | 0.16 / 1234.30 | 6 | 7 |
2 | 7 | 2010.88 | 40 | 14.46 | 3095 | 1790 | 1.95 / 1236.09 | 7 | 40 |
3 | 13 | 1983.00 | 20 | 14.44 | 3051 | 881 | 2.83 / 1236.97 | 5 | 44 |
4 | 13 | 1666.20 | 20 | 14.44 | 2635 | 761 | 3.59 / 1237.74 | 5 | 51 |
5 | 13 | 1063.24 | 20 | 14.59 | 1818 | 530 | 4.12 / 1238.27 | 5 | 60 |
6 | 13 | 484.12 | 20 | 14.81 | 1008 | 299 | 4.42 / 1238.56 | 5 | 56 |
7 | 13 | 167.96 | 20 | 14.93 | 543 | 162 | 4.58 / 1238.73 | 6 | 46 |
8 | 8 | 0.12 | 253 | 14.96 | 277 | 1048 | 5.63 / 1239.77 | 6 | 227 |
Average= | 9.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 25 | 14.97 | 428 | 160 | 0.16 / 1228.55 | 6 | 8 |
2 | 7 | 2004.28 | 41 | 14.47 | 3084 | 1830 | 1.99 / 1230.38 | 8 | 40 |
3 | 13 | 1978.36 | 20 | 14.44 | 3051 | 881 | 2.87 / 1231.27 | 5 | 46 |
4 | 13 | 1599.28 | 20 | 14.46 | 2562 | 741 | 3.61 / 1232.01 | 5 | 52 |
5 | 13 | 1175.36 | 20 | 14.54 | 1983 | 577 | 4.19 / 1232.58 | 5 | 58 |
6 | 13 | 556.52 | 20 | 14.76 | 1118 | 330 | 4.52 / 1232.91 | 5 | 64 |
7 | 13 | 122.64 | 20 | 14.94 | 486 | 145 | 4.66 / 1233.06 | 6 | 48 |
8 | 8 | 0.12 | 253 | 14.95 | 287 | 1086 | 5.75 / 1234.14 | 6 | -99 |
Average= | 9.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 25 | 14.96 | 416 | 156 | 0.16 / 1222.92 | 6 | 7 |
2 | 7 | 2011.04 | 40 | 14.46 | 3091 | 1788 | 1.94 / 1224.71 | 7 | 43 |
3 | 13 | 1984.80 | 20 | 14.44 | 3053 | 882 | 2.83 / 1225.59 | 5 | 45 |
4 | 13 | 1640.44 | 20 | 14.44 | 2602 | 751 | 3.58 / 1226.34 | 5 | 49 |
5 | 13 | 1054.80 | 20 | 14.58 | 1821 | 531 | 4.11 / 1226.88 | 5 | 62 |
6 | 13 | 430.92 | 20 | 14.80 | 951 | 281 | 4.39 / 1227.16 | 5 | 65 |
7 | 13 | 86.76 | 20 | 14.94 | 444 | 133 | 4.52 / 1227.29 | 5 | 50 |
8 | 8 | 0.04 | 250 | 14.93 | 296 | 1105 | 5.63 / 1228.39 | 6 | 149 |
Average= | 9.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 25 | 14.96 | 436 | 163 | 0.16 / 1217.98 | 6 | 8 |
2 | 7 | 1580.40 | 40 | 14.63 | 2514 | 1471 | 1.63 / 1219.45 | 8 | 49 |
3 | 13 | 1560.40 | 20 | 14.60 | 2492 | 728 | 2.36 / 1220.18 | 5 | 51 |
4 | 13 | 1530.52 | 20 | 14.55 | 2456 | 715 | 3.08 / 1220.89 | 5 | 54 |
5 | 13 | 943.60 | 20 | 14.65 | 1663 | 487 | 3.56 / 1221.38 | 5 | 62 |
6 | 13 | 235.44 | 20 | 14.90 | 666 | 198 | 3.76 / 1221.58 | 5 | 57 |
7 | 13 | 51.80 | 20 | 14.97 | 384 | 115 | 3.88 / 1221.69 | 6 | 53 |
8 | 8 | 0.00 | 246 | 14.94 | 292 | 1073 | 4.95 / 1222.77 | 6 | 239 |
Average= | 9.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 25 | 14.95 | 448 | 167 | 0.17 / 1212.74 | 6 | 8 |
2 | 7 | 1765.96 | 41 | 14.56 | 2769 | 1653 | 1.82 / 1214.39 | 8 | 46 |
3 | 13 | 1758.44 | 20 | 14.53 | 2765 | 804 | 2.62 / 1215.20 | 5 | 48 |
4 | 13 | 1521.76 | 20 | 14.52 | 2442 | 709 | 3.33 / 1215.91 | 5 | 54 |
5 | 13 | 936.52 | 20 | 14.64 | 1647 | 482 | 3.82 / 1216.39 | 5 | 62 |
6 | 13 | 280.96 | 20 | 14.87 | 740 | 220 | 4.04 / 1216.61 | 5 | 63 |
7 | 13 | 47.88 | 20 | 14.96 | 387 | 116 | 4.15 / 1216.72 | 6 | 54 |
8 | 8 | 0.04 | 244 | 14.92 | 300 | 1092 | 5.24 / 1217.82 | 6 | 129 |
Average= | 9.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 25 | 14.95 | 442 | 165 | 0.17 / 1207.56 | 6 | 10 |
2 | 7 | 1712.00 | 40 | 14.58 | 2696 | 1572 | 1.74 / 1209.13 | 10 | 47 |
3 | 13 | 1687.88 | 20 | 14.55 | 2676 | 779 | 2.52 / 1209.91 | 5 | 51 |
4 | 13 | 1454.08 | 20 | 14.55 | 2356 | 686 | 3.20 / 1210.60 | 5 | 56 |
5 | 13 | 1014.76 | 20 | 14.62 | 1758 | 514 | 3.72 / 1211.11 | 5 | 63 |
6 | 13 | 294.48 | 20 | 14.86 | 765 | 227 | 3.94 / 1211.34 | 5 | 66 |
7 | 13 | 32.96 | 20 | 14.96 | 365 | 109 | 4.05 / 1211.45 | 6 | 54 |
8 | 8 | -0.16 | 246 | 14.92 | 307 | 1127 | 5.18 / 1212.57 | 6 | 204 |
Average= | 9.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 25 | 14.97 | 421 | 158 | 0.16 / 1202.30 | 6 | 9 |
2 | 7 | 1790.52 | 41 | 14.54 | 2798 | 1668 | 1.83 / 1203.97 | 9 | 46 |
3 | 13 | 1764.72 | 20 | 14.52 | 2777 | 806 | 2.63 / 1204.77 | 5 | 49 |
4 | 13 | 1527.76 | 20 | 14.51 | 2451 | 711 | 3.34 / 1205.49 | 5 | 55 |
5 | 13 | 980.36 | 20 | 14.62 | 1713 | 501 | 3.84 / 1205.99 | 5 | 64 |
6 | 13 | 258.12 | 20 | 14.88 | 706 | 210 | 4.05 / 1206.20 | 5 | 64 |
7 | 8 | -0.04 | 265 | 14.92 | 303 | 1198 | 5.25 / 1207.39 | 6 | 185 |
Average= | 9.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 25 | 14.98 | 430 | 161 | 0.16 / 1196.68 | 6 | 8 |
2 | 7 | 2009.40 | 40 | 14.47 | 3081 | 1783 | 1.94 / 1198.47 | 8 | 42 |
3 | 13 | 1980.68 | 20 | 14.44 | 3060 | 884 | 2.83 / 1199.35 | 5 | 45 |
4 | 13 | 1735.68 | 20 | 14.43 | 2723 | 786 | 3.61 / 1200.14 | 5 | 48 |
5 | 13 | 999.40 | 20 | 14.60 | 1735 | 507 | 4.12 / 1200.64 | 5 | 63 |
6 | 13 | 382.56 | 20 | 14.83 | 878 | 260 | 4.38 / 1200.90 | 5 | 60 |
7 | 13 | 70.04 | 20 | 14.95 | 415 | 124 | 4.51 / 1201.03 | 6 | 54 |
8 | 8 | 0.00 | 250 | 14.93 | 299 | 1116 | 5.62 / 1202.14 | 6 | 168 |
Average= | 9.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 25 | 14.97 | 424 | 159 | 0.16 / 1190.97 | 6 | 8 |
2 | 7 | 2008.28 | 41 | 14.46 | 3084 | 1828 | 1.99 / 1192.80 | 8 | 41 |
3 | 13 | 1980.28 | 20 | 14.45 | 3049 | 881 | 2.87 / 1193.68 | 5 | 45 |
4 | 13 | 1663.24 | 20 | 14.45 | 2626 | 759 | 3.63 / 1194.44 | 5 | 51 |
5 | 13 | 1147.12 | 20 | 14.55 | 1940 | 565 | 4.19 / 1195.00 | 5 | 61 |
6 | 13 | 444.00 | 20 | 14.81 | 964 | 286 | 4.48 / 1195.29 | 5 | 62 |
7 | 13 | 92.04 | 20 | 14.95 | 447 | 134 | 4.61 / 1195.42 | 6 | 53 |
8 | 8 | 0.04 | 253 | 14.93 | 291 | 1099 | 5.71 / 1196.52 | 6 | 234 |
Average= | 9.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 25 | 14.96 | 445 | 166 | 0.17 / 1185.26 | 6 | 9 |
2 | 7 | 2008.92 | 40 | 14.48 | 3092 | 1791 | 1.96 / 1187.06 | 9 | 42 |
3 | 13 | 1980.32 | 20 | 14.46 | 3051 | 882 | 2.84 / 1187.94 | 5 | 43 |
4 | 13 | 1738.04 | 20 | 14.44 | 2721 | 786 | 3.63 / 1188.72 | 5 | 48 |
5 | 13 | 1130.52 | 20 | 14.56 | 1918 | 559 | 4.18 / 1189.28 | 5 | 62 |
6 | 13 | 466.92 | 20 | 14.79 | 1000 | 296 | 4.48 / 1189.58 | 5 | 67 |
7 | 13 | 51.84 | 20 | 14.96 | 385 | 115 | 4.60 / 1189.69 | 6 | 52 |
8 | 8 | -0.04 | 253 | 14.93 | 296 | 1118 | 5.71 / 1190.81 | 6 | -99 |
Average= | 9.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 25 | 14.94 | 454 | 170 | 0.17 / 1179.54 | 6 | 14 |
2 | 7 | 2012.32 | 40 | 14.48 | 3094 | 1792 | 1.96 / 1181.33 | 14 | 43 |
3 | 13 | 1986.44 | 20 | 14.45 | 3060 | 884 | 2.85 / 1182.22 | 5 | 43 |
4 | 13 | 1749.12 | 20 | 14.44 | 2740 | 791 | 3.64 / 1183.01 | 5 | 51 |
5 | 13 | 1124.68 | 20 | 14.56 | 1915 | 558 | 4.19 / 1183.57 | 5 | 60 |
6 | 13 | 489.92 | 20 | 14.78 | 1037 | 307 | 4.50 / 1183.87 | 5 | 66 |
7 | 8 | 0.00 | 270 | 14.93 | 304 | 1225 | 5.73 / 1185.10 | 6 | 163 |
Average= | 9.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 25 | 14.95 | 437 | 163 | 0.16 / 1173.78 | 6 | 9 |
2 | 7 | 2006.76 | 40 | 14.48 | 3084 | 1786 | 1.95 / 1175.56 | 9 | 41 |
3 | 13 | 1942.60 | 20 | 14.46 | 2995 | 866 | 2.82 / 1176.43 | 5 | 46 |
4 | 13 | 1586.32 | 20 | 14.47 | 2527 | 731 | 3.55 / 1177.16 | 5 | 54 |
5 | 13 | 1021.76 | 20 | 14.60 | 1769 | 517 | 4.06 / 1177.68 | 5 | 61 |
6 | 13 | 633.64 | 20 | 14.72 | 1232 | 363 | 4.43 / 1178.04 | 5 | 66 |
7 | 13 | 237.16 | 20 | 14.86 | 677 | 201 | 4.63 / 1178.24 | 5 | 69 |
8 | 8 | 0.04 | 248 | 14.91 | 306 | 1131 | 5.76 / 1179.37 | 6 | 136 |
Average= | 9.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 25 | 14.95 | 441 | 165 | 0.16 / 1168.43 | 6 | 7 |
2 | 7 | 1802.08 | 41 | 14.54 | 2815 | 1678 | 1.84 / 1170.11 | 7 | 47 |
3 | 13 | 1776.04 | 20 | 14.52 | 2766 | 803 | 2.65 / 1170.92 | 5 | 49 |
4 | 13 | 1641.44 | 20 | 14.49 | 2597 | 753 | 3.40 / 1171.67 | 5 | 50 |
5 | 13 | 954.36 | 20 | 14.63 | 1676 | 490 | 3.89 / 1172.16 | 5 | 65 |
6 | 13 | 395.84 | 20 | 14.82 | 900 | 267 | 4.16 / 1172.43 | 5 | 66 |
7 | 8 | 0.08 | 265 | 14.93 | 300 | 1187 | 5.34 / 1173.61 | 6 | 196 |
Average= | 9.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 26 | 14.96 | 442 | 172 | 0.17 / 1163.54 | 6 | 9 |
2 | 3 | 1457.16 | -1 | 15.32 | 3 | 0 | 0.00 / 1163.54 | 6 | 9 |
3 | 7 | 1575.84 | 40 | 14.63 | 2511 | 1469 | 1.64 / 1165.01 | 9 | 50 |
4 | 13 | 1557.48 | 20 | 14.61 | 2494 | 729 | 2.37 / 1165.74 | 5 | 53 |
5 | 13 | 1495.24 | 20 | 14.57 | 2408 | 702 | 3.07 / 1166.44 | 5 | 53 |
6 | 13 | 803.96 | 20 | 14.70 | 1471 | 432 | 3.50 / 1166.88 | 5 | 63 |
7 | 13 | 226.28 | 20 | 14.90 | 657 | 196 | 3.70 / 1167.07 | 5 | 60 |
8 | 8 | 0.16 | 263 | 14.93 | 305 | 1198 | 4.90 / 1168.27 | 6 | 204 |
Average= | 9.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 10 | 1511.64 | 11 | 14.63 | 2405 | 387 | 0.39 / 1157.84 | 5 | 28 |
2 | 10 | 1531.24 | 9 | 14.62 | 2429 | 320 | 0.71 / 1158.16 | 5 | 31 |
3 | 10 | 1546.48 | 7 | 14.59 | 2471 | 252 | 0.96 / 1158.41 | 5 | 33 |
4 | 10 | 1556.88 | 5 | 14.58 | 2487 | 181 | 1.14 / 1158.59 | 5 | 37 |
5 | 3 | 1466.68 | -1 | 15.24 | 3 | 0 | 0.75 / 1158.59 | 5 | 37 |
6 | 7 | 1631.08 | 40 | 14.60 | 2589 | 1512 | 2.65 / 1160.10 | 37 | 48 |
7 | 13 | 1611.00 | 20 | 14.57 | 2565 | 747 | 3.40 / 1160.85 | 5 | 51 |
8 | 13 | 1444.60 | 20 | 14.55 | 2342 | 682 | 4.08 / 1161.53 | 5 | 54 |
9 | 13 | 937.12 | 20 | 14.65 | 1653 | 484 | 4.57 / 1162.01 | 5 | 62 |
10 | 13 | 197.72 | 20 | 14.92 | 611 | 182 | 4.75 / 1162.20 | 5 | 61 |
11 | 8 | 0.24 | 263 | 14.94 | 299 | 1175 | 5.92 / 1163.37 | 6 | 164 |
Average= | 9.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 51 | 14.94 | 439 | 334 | 0.33 / 1153.68 | 6 | 17 |
2 | 7 | 1025.92 | 41 | 14.92 | 1748 | 1069 | 1.40 / 1154.75 | 17 | 42 |
3 | 13 | 1028.72 | 20 | 14.89 | 1755 | 523 | 1.93 / 1155.27 | 5 | 46 |
4 | 13 | 1005.16 | 20 | 14.85 | 1719 | 511 | 2.44 / 1155.78 | 5 | 46 |
5 | 13 | 685.80 | 20 | 14.86 | 1295 | 385 | 2.82 / 1156.17 | 5 | 54 |
6 | 13 | 112.80 | 20 | 14.99 | 485 | 145 | 2.97 / 1156.31 | 5 | 56 |
7 | 8 | 0.08 | 255 | 14.96 | 298 | 1137 | 4.10 / 1157.45 | 6 | 154 |
Average= | 9.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 51 | 14.94 | 426 | 325 | 0.32 / 1149.55 | 6 | 10 |
2 | 7 | 1021.92 | 40 | 14.91 | 1736 | 1035 | 1.36 / 1150.59 | 10 | 42 |
3 | 13 | 1027.96 | 20 | 14.88 | 1746 | 520 | 1.88 / 1151.11 | 5 | 45 |
4 | 13 | 1003.20 | 20 | 14.85 | 1710 | 508 | 2.39 / 1151.61 | 5 | 46 |
5 | 13 | 862.28 | 20 | 14.82 | 1528 | 453 | 2.84 / 1152.07 | 5 | 52 |
6 | 13 | 66.96 | 20 | 15.00 | 414 | 124 | 2.96 / 1152.19 | 5 | 54 |
7 | 8 | 0.00 | 257 | 14.96 | 300 | 1153 | 4.12 / 1153.34 | 6 | 192 |
Average= | 9.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 51 | 14.94 | 420 | 320 | 0.32 / 1145.48 | 6 | 14 |
2 | 7 | 980.96 | 40 | 14.91 | 1687 | 1006 | 1.33 / 1146.49 | 14 | 44 |
3 | 13 | 981.00 | 20 | 14.88 | 1697 | 505 | 1.83 / 1146.99 | 5 | 51 |
4 | 13 | 960.00 | 20 | 14.85 | 1663 | 494 | 2.33 / 1147.49 | 5 | 51 |
5 | 13 | 754.56 | 20 | 14.85 | 1388 | 412 | 2.74 / 1147.90 | 5 | 56 |
6 | 13 | 143.52 | 20 | 14.98 | 539 | 161 | 2.90 / 1148.06 | 5 | 65 |
7 | 8 | 0.04 | 257 | 14.96 | 303 | 1165 | 4.06 / 1149.23 | 6 | -99 |
Average= | 9.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 51 | 14.96 | 440 | 336 | 0.34 / 1141.52 | 6 | 14 |
2 | 7 | 941.56 | 41 | 14.90 | 1640 | 1002 | 1.34 / 1142.52 | 14 | 49 |
3 | 13 | 941.00 | 20 | 14.87 | 1645 | 489 | 1.83 / 1143.01 | 5 | 51 |
4 | 13 | 918.92 | 20 | 14.84 | 1611 | 478 | 2.30 / 1143.49 | 5 | 54 |
5 | 13 | 692.72 | 20 | 14.85 | 1303 | 387 | 2.69 / 1143.87 | 5 | 58 |
6 | 13 | 77.04 | 20 | 15.00 | 437 | 131 | 2.82 / 1144.00 | 5 | 57 |
7 | 8 | 0.12 | 253 | 14.96 | 306 | 1158 | 3.98 / 1145.16 | 6 | 138 |
Average= | 9.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 51 | 14.94 | 443 | 338 | 0.34 / 1138.05 | 6 | 13 |
2 | 3 | 464.60 | -1 | 15.27 | 2 | 0 | 0.00 / 1138.05 | 6 | 13 |
3 | 7 | 686.08 | 41 | 15.03 | 1293 | 797 | 1.13 / 1138.85 | 13 | 51 |
4 | 13 | 685.28 | 20 | 15.01 | 1298 | 390 | 1.52 / 1139.24 | 5 | 54 |
5 | 13 | 665.72 | 20 | 14.98 | 1267 | 380 | 1.90 / 1139.62 | 5 | 55 |
6 | 13 | 525.88 | 20 | 14.98 | 1072 | 321 | 2.22 / 1139.94 | 5 | 61 |
7 | 13 | 21.40 | 20 | 15.07 | 349 | 105 | 2.33 / 1140.05 | 6 | 57 |
8 | 8 | -0.04 | 248 | 15.01 | 305 | 1135 | 3.47 / 1141.18 | 6 | 135 |
Average= | 9.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 51 | 14.94 | 422 | 322 | 0.32 / 1133.95 | 6 | 14 |
2 | 7 | 1012.12 | 41 | 14.92 | 1729 | 1058 | 1.38 / 1135.01 | 14 | 44 |
3 | 13 | 1015.08 | 20 | 14.89 | 1732 | 516 | 1.89 / 1135.53 | 5 | 44 |
4 | 13 | 990.92 | 20 | 14.85 | 1700 | 505 | 2.40 / 1136.03 | 5 | 47 |
5 | 13 | 738.60 | 20 | 14.85 | 1363 | 405 | 2.80 / 1136.44 | 5 | 54 |
6 | 13 | 53.60 | 20 | 15.01 | 397 | 119 | 2.92 / 1136.56 | 5 | 55 |
7 | 8 | 0.04 | 255 | 14.96 | 304 | 1160 | 4.08 / 1137.72 | 6 | 162 |
Average= | 9.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 51 | 14.95 | 440 | 335 | 0.34 / 1129.90 | 6 | 14 |
2 | 7 | 1015.04 | 40 | 14.90 | 1731 | 1032 | 1.37 / 1130.93 | 14 | 41 |
3 | 13 | 1019.04 | 20 | 14.87 | 1739 | 517 | 1.88 / 1131.45 | 5 | 47 |
4 | 13 | 993.84 | 20 | 14.83 | 1703 | 505 | 2.39 / 1131.96 | 5 | 50 |
5 | 13 | 742.56 | 20 | 14.83 | 1372 | 407 | 2.80 / 1132.36 | 5 | 54 |
6 | 13 | 63.76 | 20 | 15.00 | 404 | 121 | 2.92 / 1132.48 | 6 | 53 |
7 | 8 | 0.08 | 255 | 14.96 | 301 | 1148 | 4.07 / 1133.63 | 6 | 148 |
Average= | 10.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 51 | 14.95 | 437 | 333 | 0.33 / 1126.37 | 6 | 8 |
2 | 7 | 724.72 | 40 | 15.01 | 1346 | 808 | 1.14 / 1127.18 | 8 | 54 |
3 | 13 | 723.88 | 20 | 14.99 | 1347 | 404 | 1.55 / 1127.58 | 5 | 48 |
4 | 13 | 704.20 | 20 | 14.96 | 1319 | 395 | 1.94 / 1127.98 | 5 | 53 |
5 | 13 | 568.56 | 20 | 14.95 | 1133 | 339 | 2.28 / 1128.32 | 5 | 55 |
6 | 13 | 57.04 | 20 | 15.04 | 402 | 121 | 2.40 / 1128.44 | 6 | 45 |
7 | 8 | 0.12 | 250 | 15.00 | 301 | 1129 | 3.53 / 1129.57 | 6 | 185 |
Average= | 10.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 51 | 14.95 | 436 | 332 | 0.33 / 1122.79 | 6 | 14 |
2 | 7 | 757.08 | 40 | 14.99 | 1393 | 835 | 1.17 / 1123.63 | 14 | 50 |
3 | 13 | 756.20 | 20 | 14.97 | 1388 | 416 | 1.58 / 1124.04 | 5 | 52 |
4 | 13 | 744.04 | 20 | 14.93 | 1375 | 411 | 1.99 / 1124.45 | 5 | 54 |
5 | 13 | 608.44 | 20 | 14.92 | 1189 | 355 | 2.35 / 1124.81 | 5 | 57 |
6 | 13 | 57.04 | 20 | 15.03 | 397 | 119 | 2.47 / 1124.93 | 5 | 54 |
7 | 8 | 0.08 | 250 | 14.99 | 297 | 1113 | 3.58 / 1126.04 | 6 | 133 |
Average= | 10.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 51 | 14.95 | 414 | 316 | 0.32 / 1119.29 | 6 | 12 |
2 | 7 | 715.96 | 40 | 15.01 | 1335 | 802 | 1.12 / 1120.09 | 12 | 53 |
3 | 13 | 715.12 | 20 | 14.98 | 1336 | 400 | 1.52 / 1120.49 | 5 | 53 |
4 | 13 | 697.04 | 20 | 14.95 | 1314 | 393 | 1.91 / 1120.88 | 5 | 54 |
5 | 13 | 562.76 | 20 | 14.94 | 1128 | 337 | 2.25 / 1121.22 | 5 | 59 |
6 | 13 | 61.92 | 20 | 15.04 | 402 | 121 | 2.37 / 1121.34 | 5 | 56 |
7 | 8 | 0.08 | 250 | 14.99 | 298 | 1117 | 3.49 / 1122.46 | 6 | 139 |
Average= | 10.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 51 | 14.94 | 424 | 323 | 0.32 / 1115.68 | 6 | 14 |
2 | 7 | 765.96 | 40 | 15.00 | 1399 | 839 | 1.16 / 1116.52 | 14 | 49 |
3 | 13 | 765.12 | 20 | 14.98 | 1410 | 422 | 1.58 / 1116.94 | 5 | 48 |
4 | 13 | 757.32 | 20 | 14.94 | 1390 | 415 | 2.00 / 1117.35 | 5 | 52 |
5 | 13 | 590.60 | 20 | 14.94 | 1163 | 348 | 2.35 / 1117.70 | 5 | 54 |
6 | 13 | 87.76 | 20 | 15.03 | 446 | 134 | 2.48 / 1117.84 | 5 | 54 |
7 | 8 | 0.12 | 253 | 14.99 | 300 | 1138 | 3.62 / 1118.97 | 6 | -99 |
Average= | 10.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 51 | 14.96 | 429 | 327 | 0.33 / 1111.98 | 6 | 15 |
2 | 7 | 789.76 | 41 | 14.98 | 1435 | 881 | 1.21 / 1112.87 | 15 | 48 |
3 | 13 | 788.88 | 20 | 14.96 | 1441 | 431 | 1.64 / 1113.30 | 5 | 53 |
4 | 13 | 788.84 | 20 | 14.91 | 1436 | 428 | 2.07 / 1113.72 | 5 | 52 |
5 | 13 | 658.28 | 20 | 14.90 | 1256 | 374 | 2.44 / 1114.10 | 5 | 56 |
6 | 13 | 94.76 | 20 | 15.01 | 462 | 139 | 2.58 / 1114.24 | 5 | 56 |
7 | 8 | 0.04 | 250 | 14.98 | 298 | 1116 | 3.70 / 1115.35 | 6 | 140 |
Average= | 10.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 51 | 14.96 | 429 | 327 | 0.33 / 1108.73 | 6 | 13 |
2 | 7 | 570.96 | 40 | 15.08 | 1131 | 682 | 1.01 / 1109.41 | 13 | 50 |
3 | 13 | 570.28 | 20 | 15.06 | 1134 | 342 | 1.35 / 1109.76 | 5 | 49 |
4 | 13 | 553.28 | 20 | 15.03 | 1105 | 332 | 1.68 / 1110.09 | 5 | 53 |
5 | 13 | 488.84 | 20 | 15.01 | 1020 | 306 | 1.99 / 1110.39 | 5 | 57 |
6 | 13 | 86.64 | 20 | 15.08 | 448 | 135 | 2.12 / 1110.53 | 5 | 59 |
7 | 8 | 0.04 | 249 | 15.03 | 301 | 1126 | 3.25 / 1111.66 | 6 | -99 |
Average= | 10.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 51 | 14.97 | 423 | 323 | 0.32 / 1105.58 | 6 | 13 |
2 | 7 | 537.48 | 41 | 15.08 | 1083 | 670 | 0.99 / 1106.25 | 13 | 52 |
3 | 13 | 536.84 | 20 | 15.06 | 1087 | 327 | 1.32 / 1106.58 | 5 | 53 |
4 | 13 | 523.72 | 20 | 15.03 | 1071 | 322 | 1.64 / 1106.90 | 5 | 55 |
5 | 13 | 391.64 | 20 | 15.03 | 891 | 268 | 1.91 / 1107.17 | 5 | 59 |
6 | 13 | 75.28 | 20 | 15.08 | 430 | 130 | 2.04 / 1107.30 | 6 | 57 |
7 | 8 | 0.08 | 246 | 15.03 | 300 | 1109 | 3.15 / 1108.41 | 6 | 207 |
Average= | 10.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 51 | 14.95 | 418 | 319 | 0.32 / 1102.43 | 6 | 15 |
2 | 7 | 522.92 | 40 | 15.11 | 1060 | 641 | 0.96 / 1103.08 | 15 | 52 |
3 | 13 | 522.32 | 20 | 15.09 | 1062 | 321 | 1.28 / 1103.40 | 5 | 52 |
4 | 13 | 507.12 | 20 | 15.06 | 1042 | 314 | 1.59 / 1103.71 | 5 | 50 |
5 | 13 | 442.44 | 20 | 15.04 | 956 | 288 | 1.88 / 1104.00 | 5 | 57 |
6 | 13 | 86.20 | 20 | 15.10 | 443 | 134 | 2.02 / 1104.13 | 5 | 56 |
7 | 8 | 0.08 | 246 | 15.05 | 304 | 1125 | 3.14 / 1105.26 | 6 | 138 |
Average= | 10.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 51 | 14.93 | 425 | 324 | 0.32 / 1098.92 | 6 | 16 |
2 | 7 | 739.68 | 40 | 15.01 | 1367 | 821 | 1.14 / 1099.74 | 16 | 48 |
3 | 13 | 738.88 | 20 | 14.98 | 1370 | 410 | 1.55 / 1100.15 | 5 | 54 |
4 | 13 | 719.48 | 20 | 14.95 | 1339 | 400 | 1.96 / 1100.55 | 5 | 52 |
5 | 13 | 517.48 | 20 | 14.96 | 1057 | 316 | 2.27 / 1100.87 | 5 | 61 |
6 | 13 | 90.08 | 20 | 15.03 | 449 | 135 | 2.41 / 1101.00 | 5 | 49 |
7 | 8 | 0.04 | 250 | 14.99 | 297 | 1113 | 3.52 / 1102.12 | 6 | 146 |
Average= | 10.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 51 | 14.93 | 420 | 320 | 0.32 / 1094.93 | 6 | 9 |
2 | 7 | 981.44 | 40 | 14.91 | 1693 | 1010 | 1.33 / 1095.94 | 9 | 46 |
3 | 13 | 979.52 | 20 | 14.88 | 1689 | 503 | 1.83 / 1096.44 | 5 | 51 |
4 | 13 | 956.60 | 20 | 14.84 | 1663 | 494 | 2.33 / 1096.94 | 5 | 50 |
5 | 13 | 682.12 | 20 | 14.85 | 1291 | 383 | 2.71 / 1097.32 | 5 | 56 |
6 | 13 | 115.56 | 20 | 14.99 | 487 | 146 | 2.86 / 1097.47 | 5 | 53 |
7 | 8 | 0.08 | 257 | 14.96 | 294 | 1130 | 3.99 / 1098.60 | 6 | 129 |
Average= | 10.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 50 | 14.93 | 433 | 323 | 0.32 / 1090.96 | 6 | 10 |
2 | 3 | 537.56 | 1 | 15.08 | 1069 | 16 | 0.34 / 1090.98 | 6 | 37 |
3 | 7 | 925.84 | 41 | 14.92 | 1620 | 991 | 1.33 / 1091.97 | 37 | 46 |
4 | 13 | 920.76 | 20 | 14.90 | 1619 | 482 | 1.81 / 1092.45 | 5 | 48 |
5 | 13 | 899.20 | 20 | 14.86 | 1591 | 473 | 2.29 / 1092.92 | 5 | 53 |
6 | 13 | 611.56 | 20 | 14.88 | 1199 | 357 | 2.64 / 1093.28 | 5 | 57 |
7 | 13 | 135.72 | 20 | 14.99 | 518 | 155 | 2.80 / 1093.43 | 5 | 54 |
8 | 13 | 69.56 | 20 | 14.99 | 420 | 126 | 2.92 / 1093.56 | 6 | 48 |
9 | 8 | 0.04 | 235 | 14.96 | 299 | 1051 | 3.97 / 1094.61 | 6 | -99 |
Average= | 10.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 773.12 | -11 | 15.28 | 3 | 0 | 0.00 / 1087.23 | 6 | 6 |
2 | 7 | 772.80 | 41 | 14.96 | 1420 | 871 | 0.87 / 1088.10 | 6 | 56 |
3 | 13 | 771.92 | 20 | 14.94 | 1426 | 426 | 1.30 / 1088.53 | 5 | 56 |
4 | 13 | 752.44 | 20 | 14.92 | 1392 | 415 | 1.71 / 1088.94 | 5 | 58 |
5 | 13 | 653.56 | 20 | 14.90 | 1262 | 376 | 2.09 / 1089.32 | 5 | 63 |
6 | 13 | 136.20 | 20 | 15.00 | 526 | 158 | 2.25 / 1089.48 | 5 | 59 |
7 | 13 | 16.60 | 20 | 15.02 | 338 | 102 | 2.35 / 1089.58 | 6 | 52 |
8 | 8 | -0.08 | 231 | 14.97 | 306 | 1058 | 3.41 / 1090.64 | 6 | 138 |
Average= | 10.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 777.56 | -11 | 15.27 | 3 | 0 | 0.00 / 1083.95 | 6 | 6 |
2 | 7 | 777.64 | 40 | 14.97 | 1425 | 853 | 0.85 / 1084.80 | 6 | 54 |
3 | 13 | 776.76 | 20 | 14.94 | 1431 | 428 | 1.28 / 1085.23 | 5 | 59 |
4 | 13 | 756.24 | 20 | 14.91 | 1398 | 417 | 1.70 / 1085.65 | 5 | 57 |
5 | 13 | 484.20 | 20 | 14.94 | 1021 | 305 | 2.00 / 1085.95 | 5 | 65 |
6 | 13 | 74.80 | 20 | 15.02 | 427 | 128 | 2.13 / 1086.08 | 6 | 56 |
7 | 8 | 0.16 | 253 | 14.97 | 304 | 1151 | 3.28 / 1087.23 | 6 | -99 |
Average= | 10.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 769.36 | -11 | 15.28 | 3 | 0 | 0.00 / 1080.57 | 6 | 6 |
2 | 7 | 769.20 | 40 | 14.98 | 1418 | 850 | 0.85 / 1081.42 | 6 | 55 |
3 | 13 | 768.32 | 20 | 14.96 | 1409 | 422 | 1.27 / 1081.84 | 5 | 55 |
4 | 13 | 749.16 | 20 | 14.93 | 1381 | 412 | 1.68 / 1082.26 | 5 | 57 |
5 | 13 | 648.20 | 20 | 14.91 | 1238 | 369 | 2.05 / 1082.63 | 5 | 60 |
6 | 13 | 108.08 | 20 | 15.01 | 481 | 144 | 2.20 / 1082.77 | 5 | 58 |
7 | 13 | 40.16 | 20 | 15.02 | 379 | 114 | 2.31 / 1082.88 | 6 | 56 |
8 | 8 | 0.08 | 233 | 14.97 | 305 | 1064 | 3.38 / 1083.95 | 6 | 183 |
Average= | 10.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 751.04 | -12 | 15.27 | 3 | 0 | 0.00 / 1077.28 | 6 | 6 |
2 | 7 | 756.20 | 40 | 14.99 | 1392 | 835 | 0.84 / 1078.11 | 6 | 54 |
3 | 13 | 755.36 | 20 | 14.97 | 1387 | 415 | 1.25 / 1078.53 | 5 | 55 |
4 | 13 | 737.32 | 20 | 14.93 | 1367 | 408 | 1.66 / 1078.94 | 5 | 57 |
5 | 13 | 569.72 | 20 | 14.93 | 1138 | 340 | 2.00 / 1079.28 | 5 | 62 |
6 | 13 | 109.56 | 20 | 15.01 | 484 | 145 | 2.14 / 1079.42 | 5 | 60 |
7 | 8 | 0.04 | 253 | 14.98 | 304 | 1152 | 3.30 / 1080.57 | 6 | 147 |
Average= | 11.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 733.60 | -12 | 15.27 | 3 | 0 | 0.00 / 1074.03 | 6 | 6 |
2 | 7 | 729.60 | 40 | 14.99 | 1358 | 814 | 0.81 / 1074.84 | 6 | 56 |
3 | 13 | 728.76 | 20 | 14.97 | 1356 | 406 | 1.22 / 1075.25 | 5 | 57 |
4 | 13 | 709.20 | 20 | 14.94 | 1330 | 397 | 1.62 / 1075.65 | 5 | 59 |
5 | 13 | 574.56 | 20 | 14.94 | 1145 | 342 | 1.96 / 1075.99 | 5 | 64 |
6 | 13 | 89.12 | 20 | 15.03 | 457 | 137 | 2.10 / 1076.13 | 5 | 61 |
7 | 8 | 0.04 | 250 | 14.99 | 307 | 1150 | 3.25 / 1077.28 | 6 | 132 |
Average= | 11.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 749.40 | -12 | 15.27 | 3 | 0 | 0.00 / 1070.79 | 6 | 6 |
2 | 7 | 749.56 | 40 | 14.98 | 1387 | 831 | 0.83 / 1071.62 | 6 | 54 |
3 | 13 | 748.72 | 20 | 14.96 | 1387 | 415 | 1.25 / 1072.04 | 5 | 58 |
4 | 13 | 729.88 | 20 | 14.92 | 1360 | 406 | 1.65 / 1072.44 | 5 | 59 |
5 | 13 | 557.44 | 20 | 14.93 | 1117 | 334 | 1.99 / 1072.78 | 5 | 62 |
6 | 13 | 47.52 | 20 | 15.03 | 391 | 118 | 2.10 / 1072.90 | 5 | 57 |
7 | 8 | 0.12 | 250 | 14.98 | 303 | 1135 | 3.24 / 1074.03 | 6 | 169 |
Average= | 11.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 741.44 | -12 | 15.28 | 3 | 0 | 0.00 / 1067.54 | 6 | 6 |
2 | 7 | 741.76 | 40 | 14.98 | 1377 | 825 | 0.83 / 1068.36 | 6 | 53 |
3 | 13 | 740.92 | 20 | 14.96 | 1375 | 411 | 1.24 / 1068.77 | 5 | 56 |
4 | 13 | 721.60 | 20 | 14.94 | 1345 | 402 | 1.64 / 1069.17 | 5 | 57 |
5 | 13 | 620.56 | 20 | 14.92 | 1205 | 360 | 2.00 / 1069.53 | 5 | 59 |
6 | 13 | 74.76 | 20 | 15.03 | 428 | 129 | 2.13 / 1069.66 | 5 | 54 |
7 | 8 | 0.00 | 253 | 14.98 | 298 | 1129 | 3.26 / 1070.79 | 6 | 204 |
Average= | 11.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 709.88 | -12 | 15.27 | 3 | 0 | 0.00 / 1064.37 | 6 | 6 |
2 | 7 | 709.56 | 40 | 14.99 | 1330 | 797 | 0.80 / 1065.17 | 6 | 54 |
3 | 13 | 708.76 | 20 | 14.97 | 1333 | 399 | 1.20 / 1065.57 | 5 | 57 |
4 | 13 | 690.48 | 20 | 14.94 | 1310 | 391 | 1.59 / 1065.96 | 5 | 59 |
5 | 13 | 524.44 | 20 | 14.94 | 1074 | 321 | 1.91 / 1066.28 | 5 | 60 |
6 | 13 | 108.20 | 20 | 15.03 | 475 | 143 | 2.05 / 1066.42 | 5 | 58 |
7 | 8 | 0.04 | 253 | 14.99 | 294 | 1115 | 3.17 / 1067.54 | 6 | 165 |
Average= | 11.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 690.76 | -13 | 15.28 | 3 | 0 | 0.00 / 1061.24 | 6 | 6 |
2 | 7 | 688.44 | 40 | 15.00 | 1303 | 782 | 0.78 / 1062.02 | 6 | 53 |
3 | 13 | 687.64 | 20 | 14.98 | 1307 | 392 | 1.17 / 1062.41 | 5 | 57 |
4 | 13 | 672.80 | 20 | 14.94 | 1282 | 383 | 1.56 / 1062.79 | 5 | 63 |
5 | 13 | 508.96 | 20 | 14.95 | 1059 | 317 | 1.87 / 1063.11 | 5 | 62 |
6 | 13 | 126.68 | 20 | 15.02 | 505 | 152 | 2.03 / 1063.26 | 5 | 59 |
7 | 8 | 0.08 | 250 | 14.99 | 296 | 1109 | 3.13 / 1064.37 | 6 | 141 |
Average= | 11.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 671.44 | -13 | 15.28 | 3 | 0 | 0.00 / 1058.10 | 6 | 6 |
2 | 7 | 671.52 | 41 | 15.03 | 1269 | 782 | 0.78 / 1058.88 | 6 | 50 |
3 | 13 | 670.76 | 20 | 15.01 | 1270 | 381 | 1.16 / 1059.26 | 5 | 53 |
4 | 13 | 653.56 | 20 | 14.98 | 1241 | 372 | 1.54 / 1059.63 | 5 | 56 |
5 | 13 | 589.68 | 20 | 14.96 | 1161 | 347 | 1.88 / 1059.98 | 5 | 56 |
6 | 13 | 113.84 | 20 | 15.04 | 482 | 145 | 2.03 / 1060.12 | 6 | 54 |
7 | 8 | 0.24 | 253 | 15.00 | 293 | 1112 | 3.14 / 1061.24 | 6 | -99 |
Average= | 11.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 687.72 | -13 | 15.28 | 3 | 0 | 0.00 / 1054.94 | 6 | 6 |
2 | 7 | 687.88 | 40 | 15.00 | 1301 | 781 | 0.78 / 1055.72 | 6 | 54 |
3 | 13 | 687.16 | 20 | 14.98 | 1303 | 390 | 1.17 / 1056.11 | 5 | 56 |
4 | 13 | 677.92 | 20 | 14.95 | 1290 | 386 | 1.56 / 1056.50 | 5 | 59 |
5 | 13 | 546.44 | 20 | 14.94 | 1106 | 330 | 1.89 / 1056.83 | 5 | 60 |
6 | 13 | 91.68 | 20 | 15.03 | 455 | 137 | 2.02 / 1056.96 | 6 | 51 |
7 | 8 | -0.12 | 253 | 14.99 | 299 | 1134 | 3.16 / 1058.10 | 6 | 141 |
Average= | 11.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 683.44 | -13 | 15.28 | 3 | 0 | 0.00 / 1051.77 | 6 | 6 |
2 | 7 | 683.80 | 40 | 15.02 | 1284 | 771 | 0.77 / 1052.54 | 6 | 51 |
3 | 13 | 683.04 | 20 | 15.00 | 1285 | 385 | 1.16 / 1052.93 | 5 | 55 |
4 | 13 | 666.28 | 20 | 14.96 | 1267 | 379 | 1.54 / 1053.31 | 5 | 58 |
5 | 13 | 568.80 | 20 | 14.95 | 1131 | 338 | 1.87 / 1053.65 | 5 | 59 |
6 | 13 | 106.44 | 20 | 15.03 | 474 | 142 | 2.02 / 1053.79 | 5 | 57 |
7 | 13 | 38.92 | 20 | 15.04 | 367 | 110 | 2.13 / 1053.90 | 6 | 53 |
8 | 8 | -0.08 | 231 | 14.99 | 300 | 1039 | 3.17 / 1054.94 | 6 | 154 |
Average= | 11.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 681.76 | -13 | 15.28 | 3 | 0 | 0.00 / 1048.62 | 6 | 6 |
2 | 7 | 681.88 | 40 | 15.02 | 1287 | 773 | 0.77 / 1049.39 | 6 | 51 |
3 | 13 | 681.12 | 20 | 14.99 | 1285 | 385 | 1.16 / 1049.78 | 5 | 55 |
4 | 13 | 666.88 | 20 | 14.96 | 1269 | 380 | 1.54 / 1050.16 | 5 | 56 |
5 | 13 | 568.68 | 20 | 14.95 | 1132 | 338 | 1.88 / 1050.50 | 5 | 60 |
6 | 13 | 104.44 | 20 | 15.03 | 466 | 140 | 2.02 / 1050.64 | 5 | 58 |
7 | 13 | 37.92 | 20 | 15.04 | 367 | 110 | 2.13 / 1050.75 | 6 | 54 |
8 | 8 | -0.04 | 233 | 14.99 | 294 | 1027 | 3.15 / 1051.77 | 6 | -99 |
Average= | 11.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 677.16 | -13 | 15.28 | 3 | 0 | 0.00 / 1045.52 | 6 | 6 |
2 | 7 | 677.36 | 41 | 15.02 | 1278 | 787 | 0.79 / 1046.30 | 6 | 49 |
3 | 13 | 676.60 | 20 | 15.00 | 1283 | 385 | 1.17 / 1046.69 | 5 | 56 |
4 | 13 | 657.40 | 20 | 14.97 | 1256 | 376 | 1.55 / 1047.06 | 5 | 55 |
5 | 13 | 489.00 | 20 | 14.97 | 1017 | 304 | 1.85 / 1047.37 | 5 | 56 |
6 | 13 | 62.68 | 20 | 15.04 | 406 | 122 | 1.98 / 1047.49 | 5 | 53 |
7 | 13 | 37.04 | 20 | 15.04 | 365 | 110 | 2.08 / 1047.60 | 6 | 53 |
8 | 8 | 0.12 | 231 | 14.99 | 294 | 1018 | 3.10 / 1048.62 | 6 | 175 |
Average= | 11.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 672.16 | -13 | 15.28 | 3 | 0 | 0.00 / 1042.46 | 6 | 6 |
2 | 7 | 672.12 | 40 | 15.02 | 1270 | 763 | 0.76 / 1043.22 | 6 | 51 |
3 | 13 | 671.36 | 20 | 15.00 | 1275 | 382 | 1.15 / 1043.60 | 5 | 54 |
4 | 13 | 655.28 | 20 | 14.97 | 1247 | 373 | 1.52 / 1043.97 | 5 | 54 |
5 | 13 | 422.16 | 20 | 14.98 | 929 | 278 | 1.80 / 1044.25 | 5 | 60 |
6 | 13 | 79.96 | 20 | 15.04 | 432 | 130 | 1.93 / 1044.38 | 6 | 54 |
7 | 13 | 27.36 | 20 | 15.04 | 350 | 105 | 2.03 / 1044.49 | 6 | 50 |
8 | 8 | 0.04 | 231 | 14.99 | 297 | 1028 | 3.06 / 1045.52 | 6 | 193 |
Average= | 12.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 668.48 | -13 | 15.28 | 3 | 0 | 0.00 / 1039.34 | 6 | 6 |
2 | 7 | 668.48 | 40 | 15.02 | 1274 | 765 | 0.77 / 1040.11 | 6 | 54 |
3 | 13 | 667.68 | 20 | 15.00 | 1271 | 381 | 1.15 / 1040.49 | 5 | 55 |
4 | 13 | 652.28 | 20 | 14.96 | 1249 | 374 | 1.52 / 1040.86 | 5 | 59 |
5 | 13 | 486.00 | 20 | 14.97 | 1025 | 307 | 1.83 / 1041.17 | 5 | 59 |
6 | 13 | 92.16 | 20 | 15.04 | 457 | 137 | 1.97 / 1041.30 | 5 | 59 |
7 | 13 | 29.60 | 20 | 15.04 | 361 | 109 | 2.07 / 1041.41 | 6 | 53 |
8 | 8 | 0.04 | 231 | 14.99 | 301 | 1042 | 3.12 / 1042.46 | 6 | 224 |
Average= | 12.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 670.40 | -13 | 15.28 | 3 | 0 | 0.00 / 1036.24 | 6 | 6 |
2 | 7 | 670.40 | 41 | 15.01 | 1269 | 781 | 0.78 / 1037.02 | 6 | 52 |
3 | 13 | 669.64 | 20 | 15.00 | 1266 | 380 | 1.16 / 1037.40 | 5 | 55 |
4 | 13 | 650.88 | 20 | 14.97 | 1242 | 372 | 1.53 / 1037.77 | 5 | 56 |
5 | 13 | 513.76 | 20 | 14.96 | 1051 | 314 | 1.85 / 1038.08 | 5 | 60 |
6 | 13 | 50.20 | 20 | 15.05 | 391 | 118 | 1.97 / 1038.20 | 6 | 53 |
7 | 13 | 16.84 | 20 | 15.04 | 338 | 102 | 2.07 / 1038.30 | 6 | 51 |
8 | 8 | 0.04 | 231 | 14.99 | 299 | 1035 | 3.10 / 1039.34 | 6 | 226 |
Average= | 12.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 673.60 | -13 | 15.28 | 3 | 0 | 0.00 / 1033.11 | 6 | 6 |
2 | 7 | 673.20 | 41 | 15.01 | 1279 | 787 | 0.79 / 1033.90 | 6 | 52 |
3 | 13 | 672.44 | 20 | 14.99 | 1281 | 384 | 1.17 / 1034.28 | 5 | 56 |
4 | 13 | 654.00 | 20 | 14.96 | 1247 | 373 | 1.54 / 1034.65 | 5 | 60 |
5 | 13 | 520.96 | 20 | 14.96 | 1064 | 318 | 1.86 / 1034.97 | 5 | 57 |
6 | 13 | 78.56 | 20 | 15.04 | 430 | 129 | 1.99 / 1035.10 | 5 | 56 |
7 | 13 | 24.16 | 20 | 15.04 | 345 | 104 | 2.10 / 1035.21 | 6 | 56 |
8 | 8 | 0.08 | 231 | 14.99 | 298 | 1032 | 3.13 / 1036.24 | 6 | -99 |
Average= | 12.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 682.20 | -13 | 15.28 | 3 | 0 | 0.00 / 1029.97 | 6 | 6 |
2 | 7 | 682.24 | 40 | 15.02 | 1288 | 774 | 0.77 / 1030.74 | 6 | 54 |
3 | 13 | 681.44 | 20 | 15.00 | 1288 | 386 | 1.16 / 1031.13 | 5 | 52 |
4 | 13 | 663.48 | 20 | 14.97 | 1259 | 377 | 1.54 / 1031.51 | 5 | 56 |
5 | 13 | 598.48 | 20 | 14.95 | 1174 | 351 | 1.89 / 1031.86 | 5 | 61 |
6 | 13 | 58.40 | 20 | 15.04 | 404 | 122 | 2.01 / 1031.98 | 6 | 50 |
7 | 13 | 18.84 | 20 | 15.04 | 341 | 103 | 2.11 / 1032.08 | 6 | 55 |
8 | 8 | 0.08 | 231 | 14.99 | 297 | 1028 | 3.14 / 1033.11 | 6 | 136 |
Average= | 12.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 683.08 | -13 | 15.28 | 3 | 0 | 0.00 / 1026.84 | 6 | 6 |
2 | 7 | 682.88 | 40 | 15.02 | 1290 | 775 | 0.78 / 1027.61 | 6 | 53 |
3 | 13 | 682.12 | 20 | 14.99 | 1289 | 386 | 1.16 / 1028.00 | 5 | 54 |
4 | 13 | 667.60 | 20 | 14.96 | 1269 | 380 | 1.54 / 1028.38 | 5 | 55 |
5 | 13 | 537.44 | 20 | 14.96 | 1089 | 326 | 1.87 / 1028.71 | 5 | 59 |
6 | 13 | 69.84 | 20 | 15.04 | 418 | 126 | 1.99 / 1028.83 | 5 | 55 |
7 | 13 | 19.48 | 20 | 15.04 | 342 | 103 | 2.10 / 1028.93 | 6 | 55 |
8 | 8 | 0.12 | 231 | 14.99 | 299 | 1035 | 3.13 / 1029.97 | 6 | 134 |
Average= | 12.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 697.32 | -13 | 15.28 | 3 | 0 | 0.00 / 1023.61 | 6 | 6 |
2 | 7 | 697.44 | 40 | 15.00 | 1310 | 786 | 0.79 / 1024.40 | 6 | 55 |
3 | 13 | 696.60 | 20 | 14.98 | 1312 | 393 | 1.18 / 1024.79 | 5 | 55 |
4 | 13 | 696.64 | 20 | 14.94 | 1305 | 390 | 1.57 / 1025.18 | 5 | 57 |
5 | 13 | 669.96 | 20 | 14.91 | 1272 | 379 | 1.95 / 1025.56 | 5 | 60 |
6 | 13 | 76.64 | 20 | 15.03 | 428 | 129 | 2.08 / 1025.69 | 6 | 56 |
7 | 13 | 22.92 | 20 | 15.03 | 345 | 104 | 2.18 / 1025.80 | 6 | 55 |
8 | 8 | 0.08 | 233 | 14.98 | 299 | 1044 | 3.22 / 1026.84 | 6 | -99 |
Average= | 12.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 703.40 | -12 | 15.29 | 3 | 0 | 0.00 / 1020.45 | 6 | 6 |
2 | 7 | 703.44 | 40 | 15.00 | 1317 | 790 | 0.79 / 1021.24 | 6 | 51 |
3 | 13 | 702.64 | 20 | 14.98 | 1322 | 396 | 1.19 / 1021.64 | 5 | 55 |
4 | 13 | 685.60 | 20 | 14.95 | 1296 | 388 | 1.57 / 1022.02 | 5 | 55 |
5 | 13 | 552.52 | 20 | 14.95 | 1111 | 332 | 1.91 / 1022.36 | 5 | 62 |
6 | 13 | 51.64 | 20 | 15.04 | 386 | 116 | 2.02 / 1022.47 | 6 | 52 |
7 | 13 | 17.96 | 20 | 15.04 | 336 | 101 | 2.12 / 1022.57 | 6 | 50 |
8 | 8 | 0.08 | 233 | 14.98 | 298 | 1040 | 3.16 / 1023.61 | 6 | -99 |
Average= | 12.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 711.32 | -12 | 15.29 | 3 | 0 | 0.00 / 1017.25 | 6 | 6 |
2 | 7 | 711.04 | 40 | 15.00 | 1331 | 799 | 0.80 / 1018.05 | 6 | 52 |
3 | 13 | 710.20 | 20 | 14.98 | 1336 | 400 | 1.20 / 1018.45 | 5 | 56 |
4 | 13 | 696.76 | 20 | 14.94 | 1315 | 393 | 1.59 / 1018.84 | 5 | 57 |
5 | 13 | 564.00 | 20 | 14.94 | 1127 | 337 | 1.93 / 1019.18 | 5 | 59 |
6 | 13 | 66.40 | 20 | 15.03 | 415 | 125 | 2.05 / 1019.30 | 5 | 52 |
7 | 13 | 22.28 | 20 | 15.03 | 347 | 104 | 2.16 / 1019.41 | 6 | 54 |
8 | 8 | 0.04 | 233 | 14.98 | 299 | 1044 | 3.20 / 1020.45 | 6 | -99 |
Average= | 12.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 721.32 | -12 | 15.28 | 3 | 0 | 0.00 / 1014.02 | 6 | 6 |
2 | 7 | 721.72 | 40 | 15.00 | 1340 | 804 | 0.80 / 1014.83 | 6 | 54 |
3 | 13 | 720.88 | 20 | 14.97 | 1349 | 404 | 1.21 / 1015.23 | 5 | 57 |
4 | 13 | 703.40 | 20 | 14.94 | 1317 | 394 | 1.60 / 1015.63 | 5 | 58 |
5 | 13 | 571.72 | 20 | 14.93 | 1140 | 340 | 1.94 / 1015.97 | 5 | 63 |
6 | 13 | 68.92 | 20 | 15.03 | 423 | 127 | 2.07 / 1016.09 | 5 | 51 |
7 | 13 | 22.64 | 20 | 15.03 | 355 | 107 | 2.18 / 1016.20 | 6 | 47 |
8 | 13 | 8.08 | 20 | 15.03 | 324 | 97 | 2.27 / 1016.30 | 6 | 48 |
9 | 8 | 0.08 | 212 | 14.98 | 300 | 953 | 3.23 / 1017.25 | 6 | -99 |
Average= | 13.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 718.88 | -12 | 15.28 | 3 | 0 | 0.00 / 1010.82 | 6 | 6 |
2 | 7 | 718.64 | 40 | 14.99 | 1337 | 802 | 0.80 / 1011.62 | 6 | 55 |
3 | 13 | 717.84 | 20 | 14.97 | 1342 | 402 | 1.20 / 1012.02 | 5 | 58 |
4 | 13 | 699.92 | 20 | 14.94 | 1314 | 393 | 1.60 / 1012.41 | 5 | 57 |
5 | 13 | 534.04 | 20 | 14.94 | 1087 | 325 | 1.92 / 1012.74 | 5 | 61 |
6 | 13 | 68.52 | 20 | 15.03 | 421 | 127 | 2.05 / 1012.87 | 5 | 58 |
7 | 13 | 18.52 | 20 | 15.03 | 342 | 103 | 2.15 / 1012.97 | 6 | 55 |
8 | 8 | 0.04 | 231 | 14.98 | 305 | 1055 | 3.21 / 1014.02 | 6 | -99 |
Average= | 13.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 703.20 | -12 | 15.28 | 3 | 0 | 0.00 / 1007.61 | 6 | 6 |
2 | 7 | 704.20 | 40 | 15.00 | 1323 | 794 | 0.79 / 1008.40 | 6 | 54 |
3 | 13 | 703.36 | 20 | 14.98 | 1327 | 398 | 1.19 / 1008.80 | 5 | 56 |
4 | 13 | 687.12 | 20 | 14.94 | 1304 | 390 | 1.58 / 1009.19 | 5 | 59 |
5 | 13 | 588.96 | 20 | 14.94 | 1162 | 347 | 1.93 / 1009.54 | 5 | 61 |
6 | 13 | 50.56 | 20 | 15.04 | 401 | 121 | 2.05 / 1009.66 | 6 | 59 |
7 | 13 | 16.52 | 20 | 15.03 | 345 | 104 | 2.15 / 1009.76 | 6 | 57 |
8 | 8 | -0.04 | 231 | 14.98 | 305 | 1055 | 3.21 / 1010.82 | 6 | 204 |
Average= | 13.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 718.00 | -12 | 15.29 | 3 | 0 | 0.00 / 1004.41 | 6 | 6 |
2 | 7 | 719.88 | 40 | 14.99 | 1343 | 805 | 0.81 / 1005.22 | 6 | 57 |
3 | 13 | 719.04 | 20 | 14.97 | 1343 | 402 | 1.21 / 1005.62 | 5 | 58 |
4 | 13 | 719.08 | 20 | 14.93 | 1343 | 401 | 1.61 / 1006.02 | 5 | 60 |
5 | 13 | 518.52 | 20 | 14.94 | 1061 | 317 | 1.93 / 1006.34 | 5 | 65 |
6 | 13 | 59.56 | 20 | 15.03 | 409 | 123 | 2.05 / 1006.46 | 5 | 59 |
7 | 13 | 19.32 | 20 | 15.03 | 342 | 103 | 2.15 / 1006.56 | 6 | 57 |
8 | 8 | 0.12 | 231 | 14.98 | 303 | 1048 | 3.20 / 1007.61 | 6 | 152 |
Average= | 13.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 729.40 | -12 | 15.28 | 3 | 0 | 0.00 / 1001.16 | 6 | 6 |
2 | 7 | 729.32 | 40 | 14.98 | 1358 | 814 | 0.81 / 1001.98 | 6 | 53 |
3 | 13 | 728.48 | 20 | 14.96 | 1362 | 408 | 1.22 / 1002.38 | 5 | 59 |
4 | 13 | 709.68 | 20 | 14.93 | 1329 | 397 | 1.62 / 1002.78 | 5 | 62 |
5 | 13 | 609.92 | 20 | 14.92 | 1191 | 355 | 1.97 / 1003.14 | 5 | 58 |
6 | 13 | 65.24 | 20 | 15.03 | 418 | 126 | 2.10 / 1003.26 | 5 | 59 |
7 | 13 | 18.76 | 20 | 15.03 | 343 | 103 | 2.20 / 1003.37 | 6 | 46 |
8 | 8 | 0.16 | 231 | 14.98 | 302 | 1045 | 3.25 / 1004.41 | 6 | 148 |
Average= | 13.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 725.68 | -12 | 15.28 | 3 | 0 | 0.00 / 997.89 | 6 | 6 |
2 | 7 | 725.80 | 40 | 14.99 | 1355 | 812 | 0.81 / 998.70 | 6 | 58 |
3 | 13 | 724.96 | 20 | 14.97 | 1356 | 406 | 1.22 / 999.11 | 5 | 55 |
4 | 13 | 706.88 | 20 | 14.93 | 1327 | 396 | 1.62 / 999.51 | 5 | 58 |
5 | 13 | 641.16 | 20 | 14.91 | 1233 | 368 | 1.98 / 999.87 | 5 | 59 |
6 | 13 | 94.32 | 20 | 15.02 | 465 | 140 | 2.12 / 1000.01 | 5 | 64 |
7 | 13 | 28.48 | 20 | 15.03 | 358 | 108 | 2.23 / 1000.12 | 6 | 56 |
8 | 8 | -0.08 | 231 | 14.98 | 301 | 1042 | 3.27 / 1001.16 | 6 | 211 |
Average= | 13.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 718.76 | -12 | 15.29 | 3 | 0 | 0.00 / 994.68 | 6 | 6 |
2 | 7 | 718.84 | 40 | 14.99 | 1344 | 806 | 0.81 / 995.48 | 6 | 57 |
3 | 13 | 718.04 | 20 | 14.96 | 1349 | 404 | 1.21 / 995.89 | 5 | 58 |
4 | 13 | 699.24 | 20 | 14.93 | 1317 | 393 | 1.60 / 996.28 | 5 | 59 |
5 | 13 | 497.12 | 20 | 14.94 | 1043 | 312 | 1.91 / 996.59 | 5 | 65 |
6 | 13 | 109.24 | 20 | 15.01 | 489 | 147 | 2.06 / 996.74 | 5 | 62 |
7 | 13 | 41.24 | 20 | 15.02 | 380 | 114 | 2.18 / 996.85 | 6 | 57 |
8 | 8 | -0.08 | 231 | 14.98 | 300 | 1038 | 3.21 / 997.89 | 6 | 203 |
Average= | 13.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 681.88 | -13 | 15.28 | 3 | 0 | 0.00 / 991.49 | 6 | 6 |
2 | 7 | 682.16 | 40 | 15.00 | 1287 | 772 | 0.77 / 992.26 | 6 | 54 |
3 | 13 | 681.40 | 20 | 14.98 | 1290 | 386 | 1.16 / 992.65 | 5 | 55 |
4 | 13 | 664.60 | 20 | 14.95 | 1265 | 378 | 1.54 / 993.02 | 5 | 55 |
5 | 13 | 602.24 | 20 | 14.93 | 1179 | 352 | 1.89 / 993.38 | 5 | 61 |
6 | 13 | 124.84 | 20 | 15.01 | 510 | 153 | 2.04 / 993.53 | 5 | 58 |
7 | 13 | 31.76 | 20 | 15.03 | 361 | 109 | 2.15 / 993.64 | 6 | 54 |
8 | 8 | 0.08 | 231 | 14.98 | 301 | 1042 | 3.19 / 994.68 | 6 | 172 |
Average= | 14.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 654.00 | -13 | 15.28 | 3 | 0 | 0.00 / 988.40 | 6 | 6 |
2 | 7 | 653.84 | 40 | 15.02 | 1245 | 748 | 0.75 / 989.15 | 6 | 54 |
3 | 13 | 653.12 | 20 | 14.99 | 1248 | 374 | 1.12 / 989.52 | 5 | 53 |
4 | 13 | 636.00 | 20 | 14.96 | 1229 | 368 | 1.49 / 989.89 | 5 | 58 |
5 | 13 | 538.36 | 20 | 14.95 | 1090 | 326 | 1.82 / 990.21 | 5 | 61 |
6 | 13 | 75.76 | 20 | 15.03 | 435 | 131 | 1.95 / 990.34 | 5 | 62 |
7 | 13 | 22.40 | 20 | 15.03 | 348 | 105 | 2.05 / 990.45 | 6 | 57 |
8 | 8 | 0.08 | 231 | 14.98 | 300 | 1038 | 3.09 / 991.49 | 6 | -99 |
Average= | 14.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 642.72 | -13 | 15.28 | 3 | 0 | 0.00 / 985.35 | 6 | 6 |
2 | 7 | 640.44 | 40 | 15.03 | 1226 | 737 | 0.74 / 986.08 | 6 | 51 |
3 | 13 | 639.68 | 20 | 15.01 | 1228 | 369 | 1.11 / 986.45 | 5 | 51 |
4 | 13 | 623.96 | 20 | 14.98 | 1202 | 360 | 1.47 / 986.81 | 5 | 55 |
5 | 13 | 524.44 | 20 | 14.97 | 1063 | 318 | 1.78 / 987.13 | 5 | 53 |
6 | 13 | 98.64 | 20 | 15.03 | 461 | 139 | 1.92 / 987.27 | 5 | 55 |
7 | 13 | 16.60 | 20 | 15.04 | 334 | 100 | 2.02 / 987.37 | 6 | 47 |
8 | 8 | 0.08 | 231 | 14.99 | 297 | 1028 | 3.05 / 988.40 | 6 | -99 |
Average= | 14.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 635.24 | -13 | 15.29 | 3 | 0 | 0.00 / 982.29 | 6 | 6 |
2 | 7 | 628.36 | 40 | 15.03 | 1211 | 728 | 0.73 / 983.02 | 6 | 51 |
3 | 13 | 627.68 | 20 | 15.01 | 1209 | 363 | 1.09 / 983.38 | 5 | 52 |
4 | 13 | 624.04 | 20 | 14.98 | 1204 | 361 | 1.45 / 983.74 | 5 | 53 |
5 | 13 | 558.84 | 20 | 14.96 | 1113 | 333 | 1.79 / 984.08 | 5 | 57 |
6 | 13 | 86.84 | 20 | 15.04 | 442 | 133 | 1.92 / 984.21 | 5 | 52 |
7 | 13 | 25.56 | 20 | 15.04 | 352 | 106 | 2.02 / 984.31 | 6 | 55 |
8 | 8 | 0.08 | 231 | 14.99 | 298 | 1032 | 3.06 / 985.35 | 6 | 163 |
Average= | 14.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 609.24 | -14 | 15.28 | 3 | 0 | 0.00 / 979.37 | 6 | 6 |
2 | 7 | 610.64 | 40 | 15.04 | 1181 | 710 | 0.71 / 980.08 | 6 | 49 |
3 | 13 | 609.92 | 20 | 15.03 | 1178 | 354 | 1.07 / 980.44 | 5 | 50 |
4 | 13 | 593.84 | 20 | 14.99 | 1161 | 348 | 1.41 / 980.78 | 5 | 52 |
5 | 13 | 390.04 | 20 | 15.00 | 876 | 263 | 1.68 / 981.05 | 5 | 56 |
6 | 13 | 75.36 | 20 | 15.05 | 423 | 127 | 1.80 / 981.17 | 6 | 56 |
7 | 13 | 21.92 | 20 | 15.05 | 343 | 103 | 1.91 / 981.28 | 6 | 52 |
8 | 8 | 0.08 | 229 | 15.00 | 295 | 1013 | 2.92 / 982.29 | 6 | 201 |
Average= | 14.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 586.16 | -14 | 15.28 | 3 | 0 | 0.00 / 976.42 | 6 | 6 |
2 | 7 | 587.72 | 41 | 15.05 | 1149 | 709 | 0.71 / 977.13 | 6 | 51 |
3 | 13 | 587.08 | 20 | 15.03 | 1151 | 346 | 1.06 / 977.48 | 5 | 49 |
4 | 13 | 573.16 | 20 | 15.00 | 1128 | 338 | 1.39 / 977.81 | 5 | 52 |
5 | 13 | 543.40 | 20 | 14.98 | 1089 | 326 | 1.72 / 978.14 | 5 | 57 |
6 | 13 | 71.08 | 20 | 15.05 | 419 | 126 | 1.85 / 978.27 | 6 | 57 |
7 | 8 | 0.08 | 248 | 15.00 | 297 | 1105 | 2.95 / 979.37 | 6 | 155 |
Average= | 14.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 557.96 | -15 | 15.29 | 3 | 0 | 0.00 / 973.51 | 6 | 6 |
2 | 7 | 581.12 | 41 | 15.05 | 1143 | 705 | 0.71 / 974.22 | 6 | 51 |
3 | 13 | 580.28 | 20 | 15.03 | 1144 | 344 | 1.05 / 974.56 | 5 | 54 |
4 | 13 | 563.36 | 20 | 15.00 | 1121 | 336 | 1.39 / 974.90 | 5 | 54 |
5 | 13 | 462.96 | 20 | 14.99 | 983 | 295 | 1.68 / 975.19 | 5 | 56 |
6 | 13 | 62.96 | 20 | 15.05 | 411 | 124 | 1.80 / 975.32 | 5 | 56 |
7 | 8 | 0.04 | 248 | 15.00 | 297 | 1105 | 2.91 / 976.42 | 6 | 236 |
Average= | 15.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 549.76 | -15 | 15.28 | 2 | 0 | 0.00 / 970.61 | 6 | 6 |
2 | 7 | 578.76 | 40 | 15.06 | 1136 | 684 | 0.68 / 971.30 | 6 | 50 |
3 | 13 | 578.28 | 20 | 15.04 | 1136 | 342 | 1.03 / 971.64 | 5 | 49 |
4 | 13 | 560.64 | 20 | 15.01 | 1115 | 335 | 1.36 / 971.97 | 5 | 52 |
5 | 13 | 497.56 | 20 | 14.99 | 1022 | 306 | 1.67 / 972.28 | 5 | 55 |
6 | 13 | 66.24 | 20 | 15.06 | 408 | 123 | 1.79 / 972.40 | 6 | 54 |
7 | 8 | 0.04 | 250 | 15.01 | 296 | 1111 | 2.90 / 973.51 | 6 | -99 |
Average= | 15.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 565.64 | -15 | 15.29 | 3 | 0 | 0.00 / 967.74 | 6 | 6 |
2 | 7 | 567.76 | 40 | 15.06 | 1120 | 675 | 0.68 / 968.41 | 6 | 49 |
3 | 13 | 567.08 | 20 | 15.04 | 1120 | 337 | 1.01 / 968.75 | 5 | 52 |
4 | 13 | 562.92 | 20 | 15.01 | 1117 | 335 | 1.35 / 969.08 | 5 | 53 |
5 | 13 | 497.76 | 20 | 14.99 | 1027 | 308 | 1.66 / 969.39 | 5 | 56 |
6 | 13 | 65.92 | 20 | 15.06 | 409 | 123 | 1.78 / 969.52 | 6 | 50 |
7 | 8 | 0.12 | 250 | 15.01 | 292 | 1096 | 2.87 / 970.61 | 6 | 205 |
Average= | 15.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 592.00 | -14 | 15.29 | 3 | 0 | 0.00 / 964.88 | 6 | 6 |
2 | 7 | 591.92 | 40 | 15.05 | 1155 | 695 | 0.70 / 965.57 | 6 | 49 |
3 | 13 | 591.24 | 20 | 15.03 | 1155 | 347 | 1.04 / 965.92 | 5 | 50 |
4 | 13 | 575.84 | 20 | 15.00 | 1129 | 339 | 1.38 / 966.26 | 5 | 55 |
5 | 13 | 410.96 | 20 | 15.00 | 903 | 271 | 1.65 / 966.53 | 5 | 60 |
6 | 13 | 64.32 | 20 | 15.05 | 403 | 121 | 1.77 / 966.65 | 6 | 48 |
7 | 8 | 0.00 | 248 | 15.00 | 292 | 1086 | 2.86 / 967.74 | 6 | 146 |
Average= | 15.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 616.68 | -14 | 15.29 | 3 | 0 | 0.00 / 961.92 | 6 | 6 |
2 | 7 | 616.48 | 40 | 15.05 | 1188 | 715 | 0.72 / 962.64 | 6 | 50 |
3 | 13 | 615.76 | 20 | 15.02 | 1192 | 358 | 1.07 / 963.00 | 5 | 51 |
4 | 13 | 599.32 | 20 | 15.00 | 1164 | 349 | 1.42 / 963.35 | 5 | 52 |
5 | 13 | 535.04 | 20 | 14.98 | 1080 | 324 | 1.75 / 963.67 | 5 | 56 |
6 | 13 | 70.96 | 20 | 15.05 | 413 | 124 | 1.87 / 963.79 | 6 | 51 |
7 | 8 | 0.16 | 250 | 15.01 | 289 | 1084 | 2.96 / 964.88 | 6 | 141 |
Average= | 15.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 628.52 | -14 | 15.29 | 3 | 0 | 0.00 / 958.90 | 6 | 6 |
2 | 7 | 628.32 | 40 | 15.03 | 1212 | 729 | 0.73 / 959.63 | 6 | 52 |
3 | 13 | 627.56 | 20 | 15.01 | 1214 | 364 | 1.09 / 960.00 | 5 | 53 |
4 | 13 | 610.80 | 20 | 14.98 | 1188 | 356 | 1.45 / 960.35 | 5 | 56 |
5 | 13 | 546.72 | 20 | 14.96 | 1098 | 329 | 1.78 / 960.68 | 5 | 57 |
6 | 13 | 71.28 | 20 | 15.05 | 416 | 125 | 1.90 / 960.81 | 6 | 49 |
7 | 8 | 0.00 | 253 | 15.00 | 294 | 1116 | 3.02 / 961.92 | 6 | -99 |
Average= | 16.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 643.64 | -13 | 15.30 | 3 | 0 | 0.00 / 955.90 | 6 | 6 |
2 | 7 | 643.32 | 41 | 15.03 | 1230 | 758 | 0.76 / 956.66 | 6 | 52 |
3 | 13 | 642.64 | 20 | 15.01 | 1231 | 370 | 1.13 / 957.03 | 5 | 53 |
4 | 13 | 624.68 | 20 | 14.98 | 1204 | 361 | 1.49 / 957.39 | 5 | 56 |
5 | 13 | 489.56 | 20 | 14.97 | 1019 | 305 | 1.79 / 957.69 | 5 | 58 |
6 | 13 | 99.28 | 20 | 15.04 | 452 | 136 | 1.93 / 957.83 | 6 | 54 |
7 | 8 | 0.16 | 250 | 15.01 | 287 | 1077 | 3.01 / 958.90 | 6 | -99 |
Average= | 16.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 649.88 | -13 | 15.29 | 3 | 0 | 0.00 / 952.85 | 6 | 6 |
2 | 7 | 650.00 | 40 | 15.02 | 1241 | 746 | 0.75 / 953.60 | 6 | 51 |
3 | 13 | 649.24 | 20 | 15.00 | 1241 | 372 | 1.12 / 953.97 | 5 | 54 |
4 | 13 | 632.08 | 20 | 14.97 | 1216 | 364 | 1.48 / 954.34 | 5 | 56 |
5 | 13 | 566.88 | 20 | 14.95 | 1121 | 335 | 1.82 / 954.67 | 5 | 60 |
6 | 13 | 100.64 | 20 | 15.04 | 456 | 137 | 1.95 / 954.81 | 6 | 53 |
7 | 8 | 0.08 | 253 | 15.01 | 287 | 1090 | 3.04 / 955.90 | 6 | -99 |
Average= | 16.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 654.00 | -13 | 15.29 | 3 | 0 | 0.00 / 949.78 | 6 | 6 |
2 | 7 | 654.20 | 40 | 15.02 | 1247 | 749 | 0.75 / 950.53 | 6 | 52 |
3 | 13 | 653.44 | 20 | 15.00 | 1250 | 375 | 1.12 / 950.90 | 5 | 54 |
4 | 13 | 636.12 | 20 | 14.97 | 1221 | 366 | 1.49 / 951.27 | 5 | 54 |
5 | 13 | 538.60 | 20 | 14.96 | 1086 | 325 | 1.82 / 951.59 | 5 | 57 |
6 | 13 | 108.32 | 20 | 15.04 | 469 | 141 | 1.96 / 951.74 | 6 | 53 |
7 | 13 | 17.72 | 20 | 15.05 | 331 | 100 | 2.06 / 951.84 | 6 | 48 |
8 | 8 | -0.12 | 231 | 15.00 | 294 | 1019 | 3.07 / 952.85 | 6 | 180 |
Average= | 16.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 658.96 | -13 | 15.29 | 3 | 0 | 0.00 / 946.72 | 6 | 6 |
2 | 7 | 659.20 | 40 | 15.02 | 1254 | 753 | 0.75 / 947.47 | 6 | 51 |
3 | 13 | 658.44 | 20 | 14.99 | 1257 | 377 | 1.13 / 947.85 | 5 | 55 |
4 | 13 | 643.60 | 20 | 14.96 | 1234 | 369 | 1.50 / 948.22 | 5 | 56 |
5 | 13 | 547.08 | 20 | 14.95 | 1097 | 328 | 1.83 / 948.54 | 5 | 58 |
6 | 13 | 78.64 | 20 | 15.04 | 428 | 129 | 1.96 / 948.67 | 6 | 51 |
7 | 8 | 0.12 | 250 | 15.00 | 295 | 1106 | 3.06 / 949.78 | 6 | 150 |
Average= | 16.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 664.88 | -13 | 15.29 | 3 | 0 | 0.00 / 943.63 | 6 | 6 |
2 | 7 | 665.04 | 40 | 15.02 | 1260 | 757 | 0.76 / 944.39 | 6 | 52 |
3 | 13 | 664.28 | 20 | 15.00 | 1257 | 377 | 1.13 / 944.76 | 5 | 53 |
4 | 13 | 648.24 | 20 | 14.97 | 1240 | 371 | 1.51 / 945.13 | 5 | 53 |
5 | 13 | 583.48 | 20 | 14.95 | 1146 | 343 | 1.85 / 945.48 | 5 | 60 |
6 | 13 | 73.04 | 20 | 15.04 | 419 | 126 | 1.97 / 945.60 | 6 | 45 |
7 | 8 | 0.12 | 250 | 15.00 | 297 | 1114 | 3.09 / 946.72 | 6 | 189 |
Average= | 17.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 664.92 | -13 | 15.29 | 3 | 0 | 0.00 / 940.58 | 6 | 6 |
2 | 7 | 664.72 | 41 | 15.02 | 1260 | 776 | 0.78 / 941.35 | 6 | 51 |
3 | 13 | 664.00 | 20 | 15.00 | 1266 | 380 | 1.16 / 941.73 | 5 | 53 |
4 | 13 | 645.20 | 20 | 14.97 | 1237 | 370 | 1.53 / 942.10 | 5 | 55 |
5 | 13 | 509.44 | 20 | 14.96 | 1048 | 314 | 1.84 / 942.42 | 5 | 57 |
6 | 13 | 78.56 | 20 | 15.04 | 421 | 127 | 1.97 / 942.54 | 6 | 55 |
7 | 8 | 0.12 | 248 | 15.00 | 292 | 1086 | 3.05 / 943.63 | 6 | 139 |
Average= | 17.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 676.56 | -13 | 15.29 | 3 | 0 | 0.00 / 937.49 | 6 | 6 |
2 | 7 | 676.56 | 41 | 15.01 | 1279 | 787 | 0.79 / 938.28 | 6 | 53 |
3 | 13 | 675.84 | 20 | 14.99 | 1278 | 383 | 1.17 / 938.66 | 5 | 54 |
4 | 13 | 657.68 | 20 | 14.96 | 1247 | 373 | 1.54 / 939.03 | 5 | 56 |
5 | 13 | 489.24 | 20 | 14.96 | 1021 | 305 | 1.85 / 939.34 | 5 | 57 |
6 | 13 | 58.52 | 20 | 15.04 | 399 | 120 | 1.97 / 939.46 | 5 | 50 |
7 | 8 | 0.04 | 248 | 14.99 | 301 | 1119 | 3.09 / 940.58 | 6 | 188 |
Average= | 17.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 664.20 | -13 | 15.29 | 3 | 0 | 0.00 / 934.40 | 6 | 6 |
2 | 7 | 663.68 | 40 | 15.02 | 1260 | 757 | 0.76 / 935.16 | 6 | 53 |
3 | 13 | 662.96 | 20 | 15.00 | 1262 | 379 | 1.14 / 935.54 | 5 | 53 |
4 | 13 | 645.92 | 20 | 14.97 | 1232 | 369 | 1.51 / 935.91 | 5 | 52 |
5 | 13 | 548.72 | 20 | 14.96 | 1100 | 329 | 1.83 / 936.24 | 5 | 63 |
6 | 13 | 85.00 | 20 | 15.04 | 440 | 132 | 1.97 / 936.37 | 5 | 53 |
7 | 8 | 0.04 | 250 | 15.00 | 299 | 1121 | 3.09 / 937.49 | 6 | -99 |
Average= | 18.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 651.04 | -13 | 15.29 | 3 | 0 | 0.00 / 931.33 | 6 | 6 |
2 | 7 | 650.92 | 40 | 15.02 | 1249 | 750 | 0.75 / 932.08 | 6 | 52 |
3 | 13 | 650.16 | 20 | 15.00 | 1251 | 375 | 1.13 / 932.45 | 5 | 56 |
4 | 13 | 633.40 | 20 | 14.97 | 1220 | 365 | 1.49 / 932.82 | 5 | 57 |
5 | 13 | 569.32 | 20 | 14.94 | 1147 | 343 | 1.83 / 933.16 | 5 | 60 |
6 | 13 | 68.56 | 20 | 15.04 | 416 | 125 | 1.96 / 933.28 | 6 | 55 |
7 | 8 | 0.04 | 250 | 15.00 | 298 | 1117 | 3.08 / 934.40 | 6 | 209 |
Average= | 18.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 636.64 | -13 | 15.29 | 3 | 0 | 0.00 / 928.30 | 6 | 6 |
2 | 7 | 630.12 | 40 | 15.04 | 1208 | 727 | 0.73 / 929.03 | 6 | 49 |
3 | 13 | 629.40 | 20 | 15.02 | 1214 | 365 | 1.09 / 929.39 | 5 | 52 |
4 | 13 | 612.84 | 20 | 14.99 | 1188 | 356 | 1.45 / 929.75 | 5 | 52 |
5 | 13 | 475.92 | 20 | 14.98 | 1002 | 300 | 1.75 / 930.05 | 5 | 57 |
6 | 13 | 89.52 | 20 | 15.04 | 449 | 135 | 1.88 / 930.18 | 6 | 56 |
7 | 8 | 0.08 | 251 | 15.00 | 303 | 1141 | 3.02 / 931.33 | 6 | -99 |
Average= | 18.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 622.56 | -14 | 15.29 | 3 | 0 | 0.00 / 925.32 | 6 | 6 |
2 | 7 | 623.68 | 40 | 15.04 | 1198 | 721 | 0.72 / 926.04 | 6 | 52 |
3 | 13 | 622.96 | 20 | 15.02 | 1203 | 361 | 1.08 / 926.40 | 5 | 51 |
4 | 13 | 606.80 | 20 | 14.99 | 1181 | 354 | 1.44 / 926.76 | 5 | 52 |
5 | 13 | 507.64 | 20 | 14.98 | 1044 | 313 | 1.75 / 927.07 | 5 | 58 |
6 | 13 | 43.76 | 20 | 15.06 | 380 | 114 | 1.86 / 927.19 | 6 | 53 |
7 | 8 | 0.12 | 248 | 15.01 | 300 | 1117 | 2.98 / 928.30 | 6 | 174 |
Average= | 18.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 619.92 | -14 | 15.30 | 3 | 0 | 0.00 / 922.36 | 6 | 6 |
2 | 7 | 620.04 | 40 | 15.05 | 1198 | 721 | 0.72 / 923.09 | 6 | 50 |
3 | 13 | 619.60 | 20 | 15.02 | 1204 | 362 | 1.08 / 923.45 | 5 | 52 |
4 | 13 | 604.52 | 20 | 14.99 | 1175 | 352 | 1.44 / 923.80 | 5 | 56 |
5 | 13 | 401.80 | 20 | 15.00 | 902 | 271 | 1.71 / 924.07 | 5 | 57 |
6 | 13 | 86.20 | 20 | 15.05 | 447 | 135 | 1.84 / 924.21 | 5 | 56 |
7 | 8 | 0.04 | 248 | 15.01 | 300 | 1117 | 2.96 / 925.32 | 6 | 198 |
Average= | 19.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 623.68 | -14 | 15.29 | 3 | 0 | 0.00 / 919.37 | 6 | 6 |
2 | 7 | 623.32 | 40 | 15.04 | 1203 | 724 | 0.72 / 920.09 | 6 | 55 |
3 | 13 | 622.60 | 20 | 15.02 | 1205 | 362 | 1.09 / 920.46 | 5 | 51 |
4 | 13 | 606.20 | 20 | 14.99 | 1180 | 354 | 1.44 / 920.81 | 5 | 58 |
5 | 13 | 508.84 | 20 | 14.98 | 1051 | 315 | 1.75 / 921.13 | 5 | 62 |
6 | 13 | 57.24 | 20 | 15.05 | 399 | 120 | 1.88 / 921.25 | 6 | 57 |
7 | 8 | 0.12 | 248 | 15.00 | 301 | 1120 | 2.99 / 922.36 | 6 | 186 |
Average= | 19.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 608.40 | -14 | 15.29 | 3 | 0 | 0.00 / 916.43 | 6 | 6 |
2 | 7 | 608.20 | 40 | 15.04 | 1187 | 714 | 0.71 / 917.14 | 6 | 52 |
3 | 13 | 607.52 | 20 | 15.02 | 1185 | 356 | 1.07 / 917.50 | 5 | 53 |
4 | 13 | 592.88 | 20 | 14.99 | 1165 | 349 | 1.42 / 917.85 | 5 | 56 |
5 | 13 | 463.00 | 20 | 14.99 | 987 | 296 | 1.72 / 918.14 | 5 | 57 |
6 | 13 | 32.44 | 20 | 15.06 | 358 | 108 | 1.82 / 918.25 | 6 | 51 |
7 | 8 | 0.00 | 248 | 15.01 | 301 | 1120 | 2.94 / 919.37 | 6 | 159 |
Average= | 19.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 609.68 | -14 | 15.29 | 3 | 0 | 0.00 / 913.49 | 6 | 6 |
2 | 7 | 609.84 | 40 | 15.04 | 1186 | 713 | 0.71 / 914.20 | 6 | 53 |
3 | 13 | 609.04 | 20 | 15.02 | 1191 | 358 | 1.07 / 914.56 | 5 | 54 |
4 | 13 | 592.36 | 20 | 14.99 | 1163 | 349 | 1.42 / 914.91 | 5 | 57 |
5 | 13 | 423.84 | 20 | 14.99 | 938 | 281 | 1.70 / 915.19 | 5 | 58 |
6 | 13 | 40.96 | 20 | 15.06 | 375 | 113 | 1.81 / 915.30 | 6 | 51 |
7 | 8 | 0.12 | 248 | 15.01 | 302 | 1124 | 2.94 / 916.43 | 6 | 235 |
Average= | 20.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 622.68 | -14 | 15.30 | 3 | 0 | 0.00 / 910.47 | 6 | 6 |
2 | 7 | 627.52 | 40 | 15.03 | 1214 | 730 | 0.73 / 911.20 | 6 | 54 |
3 | 13 | 626.80 | 20 | 15.01 | 1217 | 365 | 1.10 / 911.56 | 5 | 53 |
4 | 13 | 612.28 | 20 | 14.98 | 1191 | 357 | 1.45 / 911.92 | 5 | 55 |
5 | 13 | 514.16 | 20 | 14.97 | 1060 | 317 | 1.77 / 912.24 | 5 | 62 |
6 | 13 | 56.08 | 20 | 15.06 | 398 | 120 | 1.89 / 912.36 | 6 | 53 |
7 | 8 | 0.08 | 248 | 15.00 | 304 | 1131 | 3.02 / 913.49 | 6 | 146 |
Average= | 20.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 638.20 | -13 | 15.29 | 3 | 0 | 0.00 / 907.38 | 6 | 6 |
2 | 7 | 638.20 | 40 | 15.03 | 1228 | 738 | 0.74 / 908.12 | 6 | 51 |
3 | 13 | 637.48 | 20 | 15.01 | 1231 | 370 | 1.11 / 908.49 | 5 | 53 |
4 | 13 | 623.96 | 20 | 14.98 | 1213 | 363 | 1.47 / 908.85 | 5 | 59 |
5 | 13 | 593.96 | 20 | 14.95 | 1167 | 349 | 1.82 / 909.20 | 5 | 56 |
6 | 13 | 86.64 | 20 | 15.05 | 443 | 133 | 1.95 / 909.33 | 5 | 46 |
7 | 8 | 0.04 | 250 | 15.01 | 303 | 1137 | 3.09 / 910.47 | 6 | -99 |
Average= | 21.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 662.08 | -13 | 15.30 | 3 | 0 | 0.00 / 904.29 | 6 | 6 |
2 | 7 | 664.32 | 40 | 15.02 | 1265 | 760 | 0.76 / 905.05 | 6 | 53 |
3 | 13 | 663.36 | 20 | 14.99 | 1268 | 380 | 1.14 / 905.43 | 5 | 56 |
4 | 13 | 646.96 | 20 | 14.96 | 1242 | 372 | 1.51 / 905.80 | 5 | 61 |
5 | 13 | 480.24 | 20 | 14.96 | 1013 | 303 | 1.82 / 906.11 | 5 | 59 |
6 | 13 | 57.52 | 20 | 15.05 | 409 | 123 | 1.94 / 906.23 | 5 | 50 |
7 | 8 | 0.16 | 248 | 15.00 | 309 | 1149 | 3.09 / 907.38 | 6 | -99 |
Average= | 21.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 687.80 | -13 | 15.30 | 3 | 0 | 0.00 / 901.13 | 6 | 6 |
2 | 7 | 687.96 | 40 | 15.01 | 1298 | 779 | 0.78 / 901.91 | 6 | 58 |
3 | 13 | 687.20 | 20 | 14.99 | 1300 | 390 | 1.17 / 902.30 | 5 | 55 |
4 | 13 | 683.40 | 20 | 14.95 | 1295 | 387 | 1.56 / 902.68 | 5 | 61 |
5 | 13 | 583.76 | 20 | 14.94 | 1152 | 344 | 1.90 / 903.03 | 5 | 58 |
6 | 13 | 80.60 | 20 | 15.04 | 436 | 131 | 2.03 / 903.16 | 6 | 58 |
7 | 8 | 0.00 | 250 | 15.00 | 302 | 1132 | 3.16 / 904.29 | 6 | 198 |
Average= | 22.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 695.40 | -13 | 15.30 | 3 | 0 | 0.00 / 897.99 | 6 | 6 |
2 | 7 | 695.32 | 40 | 15.01 | 1307 | 785 | 0.79 / 898.78 | 6 | 53 |
3 | 13 | 694.52 | 20 | 14.98 | 1309 | 392 | 1.18 / 899.17 | 5 | 54 |
4 | 13 | 676.72 | 20 | 14.95 | 1282 | 383 | 1.56 / 899.55 | 5 | 57 |
5 | 13 | 510.48 | 20 | 14.95 | 1050 | 314 | 1.87 / 899.86 | 5 | 60 |
6 | 13 | 86.68 | 20 | 15.04 | 443 | 133 | 2.01 / 900.00 | 6 | 55 |
7 | 8 | 0.16 | 250 | 15.00 | 301 | 1129 | 3.14 / 901.13 | 6 | 139 |
Average= | 22.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 685.92 | -13 | 15.30 | 3 | 0 | 0.00 / 894.85 | 6 | 6 |
2 | 7 | 686.08 | 40 | 15.01 | 1290 | 775 | 0.78 / 895.62 | 6 | 51 |
3 | 13 | 685.32 | 20 | 14.99 | 1293 | 388 | 1.16 / 896.01 | 5 | 53 |
4 | 13 | 667.52 | 20 | 14.96 | 1269 | 380 | 1.54 / 896.39 | 5 | 56 |
5 | 13 | 603.24 | 20 | 14.94 | 1180 | 353 | 1.90 / 896.74 | 5 | 57 |
6 | 13 | 92.12 | 20 | 15.04 | 447 | 134 | 2.03 / 896.87 | 6 | 52 |
7 | 8 | 0.12 | 253 | 15.00 | 294 | 1116 | 3.15 / 897.99 | 6 | -99 |
Average= | 23.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 647.80 | -13 | 15.30 | 3 | 0 | 0.00 / 891.77 | 6 | 6 |
2 | 7 | 647.60 | 41 | 15.03 | 1237 | 762 | 0.76 / 892.53 | 6 | 53 |
3 | 13 | 646.84 | 20 | 15.01 | 1240 | 372 | 1.14 / 892.90 | 5 | 56 |
4 | 13 | 629.28 | 20 | 14.98 | 1215 | 364 | 1.50 / 893.26 | 5 | 53 |
5 | 13 | 461.04 | 20 | 14.98 | 985 | 295 | 1.79 / 893.56 | 5 | 62 |
6 | 13 | 146.76 | 20 | 15.03 | 542 | 163 | 1.96 / 893.72 | 5 | 60 |
7 | 8 | 0.08 | 248 | 15.00 | 302 | 1123 | 3.08 / 894.85 | 6 | 225 |
Average= | 23.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 628.24 | -14 | 15.30 | 3 | 0 | 0.00 / 888.69 | 6 | 6 |
2 | 7 | 632.08 | 40 | 15.04 | 1219 | 733 | 0.73 / 889.42 | 6 | 53 |
3 | 13 | 631.32 | 20 | 15.01 | 1219 | 366 | 1.10 / 889.79 | 5 | 57 |
4 | 13 | 614.44 | 20 | 14.99 | 1193 | 358 | 1.46 / 890.15 | 5 | 54 |
5 | 13 | 514.52 | 20 | 14.98 | 1058 | 317 | 1.77 / 890.46 | 5 | 58 |
6 | 13 | 151.04 | 20 | 15.03 | 551 | 166 | 1.94 / 890.63 | 5 | 63 |
7 | 13 | 17.84 | 20 | 15.06 | 337 | 102 | 2.04 / 890.73 | 6 | 57 |
8 | 8 | 0.00 | 229 | 15.00 | 301 | 1034 | 3.08 / 891.77 | 6 | -99 |
Average= | 24.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 576.92 | -14 | 15.30 | 3 | 0 | 0.00 / 885.75 | 6 | 6 |
2 | 7 | 595.64 | 40 | 15.05 | 1168 | 703 | 0.70 / 886.45 | 6 | 52 |
3 | 13 | 594.92 | 20 | 15.02 | 1170 | 351 | 1.06 / 886.80 | 5 | 54 |
4 | 13 | 580.32 | 20 | 15.00 | 1146 | 344 | 1.40 / 887.15 | 5 | 56 |
5 | 13 | 410.44 | 20 | 15.00 | 921 | 276 | 1.68 / 887.42 | 5 | 61 |
6 | 13 | 102.28 | 20 | 15.05 | 470 | 141 | 1.82 / 887.56 | 5 | 59 |
7 | 8 | 0.00 | 248 | 15.01 | 303 | 1128 | 2.94 / 888.69 | 6 | -99 |
Average= | 24.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 553.64 | -15 | 15.30 | 3 | 0 | 0.00 / 882.87 | 6 | 6 |
2 | 7 | 556.12 | 40 | 15.07 | 1110 | 669 | 0.67 / 883.54 | 6 | 49 |
3 | 13 | 555.36 | 20 | 15.05 | 1111 | 334 | 1.00 / 883.88 | 5 | 51 |
4 | 13 | 538.04 | 20 | 15.03 | 1081 | 325 | 1.33 / 884.20 | 5 | 53 |
5 | 13 | 474.00 | 20 | 15.01 | 997 | 299 | 1.63 / 884.50 | 5 | 54 |
6 | 13 | 93.24 | 20 | 15.06 | 454 | 137 | 1.77 / 884.64 | 6 | 54 |
7 | 8 | 0.00 | 246 | 15.02 | 300 | 1108 | 2.87 / 885.75 | 6 | 146 |
Average= | 25.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 560.36 | -15 | 15.31 | 3 | 0 | 0.00 / 880.00 | 6 | 6 |
2 | 7 | 565.56 | 40 | 15.06 | 1120 | 675 | 0.68 / 880.67 | 6 | 48 |
3 | 13 | 564.76 | 20 | 15.04 | 1122 | 337 | 1.01 / 881.01 | 5 | 51 |
4 | 13 | 549.88 | 20 | 15.01 | 1097 | 329 | 1.34 / 881.34 | 5 | 55 |
5 | 13 | 486.52 | 20 | 15.00 | 1014 | 304 | 1.65 / 881.64 | 5 | 56 |
6 | 13 | 51.12 | 20 | 15.07 | 388 | 117 | 1.76 / 881.76 | 6 | 47 |
7 | 8 | 0.12 | 248 | 15.02 | 299 | 1114 | 2.88 / 882.87 | 6 | 159 |
Average= | 25.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 581.84 | -14 | 15.31 | 3 | 0 | 0.00 / 877.15 | 6 | 6 |
2 | 7 | 581.96 | 40 | 15.07 | 1140 | 687 | 0.69 / 877.84 | 6 | 48 |
3 | 13 | 581.28 | 20 | 15.05 | 1137 | 342 | 1.03 / 878.18 | 5 | 48 |
4 | 13 | 564.76 | 20 | 15.02 | 1119 | 336 | 1.37 / 878.51 | 5 | 50 |
5 | 13 | 397.84 | 20 | 15.03 | 885 | 266 | 1.63 / 878.78 | 5 | 55 |
6 | 13 | 86.60 | 20 | 15.07 | 437 | 132 | 1.76 / 878.91 | 6 | 46 |
7 | 8 | 0.00 | 248 | 15.03 | 291 | 1085 | 2.85 / 880.00 | 6 | 152 |
Average= | 26.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 590.60 | -14 | 15.31 | 3 | 0 | 0.00 / 874.24 | 6 | 6 |
2 | 7 | 590.92 | 40 | 15.06 | 1154 | 695 | 0.70 / 874.94 | 6 | 51 |
3 | 13 | 590.20 | 20 | 15.04 | 1155 | 347 | 1.04 / 875.29 | 5 | 51 |
4 | 13 | 575.40 | 20 | 15.01 | 1134 | 340 | 1.38 / 875.63 | 5 | 55 |
5 | 13 | 409.68 | 20 | 15.01 | 909 | 273 | 1.66 / 875.90 | 5 | 57 |
6 | 13 | 97.88 | 20 | 15.06 | 462 | 139 | 1.80 / 876.04 | 6 | 52 |
7 | 8 | 0.08 | 248 | 15.02 | 298 | 1110 | 2.91 / 877.15 | 6 | 199 |
Average= | 27.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 619.64 | -14 | 15.32 | 3 | 0 | 0.00 / 871.26 | 6 | 6 |
2 | 7 | 611.44 | 41 | 15.06 | 1190 | 735 | 0.74 / 871.99 | 6 | 55 |
3 | 13 | 610.36 | 20 | 15.03 | 1196 | 360 | 1.09 / 872.35 | 5 | 55 |
4 | 13 | 592.32 | 20 | 15.01 | 1165 | 350 | 1.44 / 872.70 | 5 | 58 |
5 | 13 | 492.36 | 20 | 15.00 | 1024 | 307 | 1.75 / 873.01 | 5 | 61 |
6 | 13 | 106.44 | 20 | 15.07 | 474 | 143 | 1.89 / 873.15 | 6 | 56 |
7 | 8 | -0.04 | 248 | 15.03 | 293 | 1092 | 2.99 / 874.24 | 6 | 130 |
Average= | 28.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 810.04 | -11 | 15.33 | 3 | 0 | 0.00 / 867.88 | 6 | 6 |
2 | 7 | 810.16 | 40 | 14.97 | 1471 | 881 | 0.88 / 868.76 | 6 | 55 |
3 | 13 | 809.20 | 20 | 14.95 | 1471 | 440 | 1.32 / 869.20 | 5 | 56 |
4 | 13 | 787.96 | 20 | 14.92 | 1440 | 430 | 1.75 / 869.63 | 5 | 60 |
5 | 13 | 548.52 | 20 | 14.93 | 1110 | 331 | 2.08 / 869.96 | 5 | 63 |
6 | 13 | 122.72 | 20 | 15.03 | 502 | 151 | 2.23 / 870.11 | 6 | 52 |
7 | 13 | 56.84 | 20 | 15.04 | 394 | 119 | 2.35 / 870.23 | 6 | 46 |
8 | 8 | 0.04 | 233 | 15.00 | 294 | 1028 | 3.38 / 871.26 | 6 | 172 |
Average= | 29.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 6 | 15.00 | 437 | 39 | 0.04 / 863.94 | 6 | 6 |
2 | 3 | 1102.16 | -6 | 15.33 | 3 | 0 | 0.00 / 863.94 | 6 | 6 |
3 | 7 | 1101.80 | 40 | 14.84 | 1874 | 1112 | 1.15 / 865.05 | 6 | 54 |
4 | 13 | 1100.52 | 20 | 14.82 | 1878 | 557 | 1.71 / 865.61 | 5 | 57 |
5 | 13 | 1075.00 | 20 | 14.78 | 1832 | 542 | 2.25 / 866.15 | 5 | 60 |
6 | 13 | 653.32 | 20 | 14.84 | 1264 | 375 | 2.63 / 866.53 | 5 | 66 |
7 | 13 | 161.88 | 20 | 14.99 | 562 | 168 | 2.79 / 866.70 | 5 | 59 |
8 | 13 | 58.76 | 20 | 15.01 | 400 | 120 | 2.91 / 866.82 | 6 | 47 |
9 | 8 | -0.08 | 238 | 14.98 | 298 | 1062 | 3.98 / 867.88 | 6 | 200 |
Average= | 29.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 16 | 14.99 | 424 | 102 | 0.10 / 859.67 | 6 | 7 |
2 | 3 | 1275.28 | -4 | 15.33 | 3 | 0 | 0.00 / 859.67 | 6 | 7 |
3 | 7 | 1275.60 | 40 | 14.76 | 2100 | 1240 | 1.34 / 860.90 | 7 | 52 |
4 | 13 | 1262.52 | 20 | 14.75 | 2097 | 619 | 1.96 / 861.52 | 5 | 57 |
5 | 13 | 1233.64 | 20 | 14.70 | 2054 | 604 | 2.56 / 862.13 | 5 | 59 |
6 | 13 | 796.04 | 20 | 14.77 | 1465 | 433 | 3.00 / 862.56 | 5 | 66 |
7 | 13 | 152.76 | 20 | 14.98 | 549 | 164 | 3.16 / 862.72 | 5 | 56 |
8 | 13 | 26.28 | 20 | 15.02 | 347 | 104 | 3.27 / 862.83 | 6 | 49 |
9 | 8 | -0.04 | 240 | 14.97 | 299 | 1074 | 4.34 / 863.90 | 6 | 178 |
Average= | 30.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 24 | 15.00 | 425 | 153 | 0.15 / 855.26 | 6 | 6 |
2 | 3 | 1315.44 | -3 | 15.34 | 3 | 0 | 0.00 / 855.26 | 6 | 6 |
3 | 7 | 1316.32 | 40 | 14.74 | 2164 | 1276 | 1.43 / 856.54 | 6 | 53 |
4 | 13 | 1301.16 | 20 | 14.72 | 2148 | 632 | 2.06 / 857.17 | 5 | 53 |
5 | 13 | 1271.36 | 20 | 14.68 | 2101 | 617 | 2.68 / 857.78 | 5 | 58 |
6 | 13 | 826.56 | 20 | 14.76 | 1502 | 443 | 3.12 / 858.23 | 5 | 65 |
7 | 13 | 151.84 | 20 | 14.98 | 542 | 162 | 3.28 / 858.39 | 5 | 60 |
8 | 13 | 28.72 | 20 | 15.02 | 352 | 106 | 3.39 / 858.50 | 6 | 54 |
9 | 8 | 0.16 | 240 | 14.97 | 297 | 1067 | 4.46 / 859.56 | 6 | 244 |
Average= | 31.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 24 | 15.00 | 419 | 151 | 0.15 / 850.73 | 6 | 8 |
2 | 7 | 1404.80 | 40 | 14.71 | 2281 | 1342 | 1.49 / 852.07 | 8 | 54 |
3 | 13 | 1385.88 | 20 | 14.69 | 2271 | 667 | 2.16 / 852.74 | 5 | 56 |
4 | 13 | 1287.60 | 20 | 14.66 | 2124 | 623 | 2.78 / 853.36 | 5 | 59 |
5 | 13 | 779.76 | 20 | 14.76 | 1432 | 423 | 3.21 / 853.78 | 5 | 65 |
6 | 13 | 146.84 | 20 | 14.98 | 532 | 159 | 3.37 / 853.94 | 5 | 55 |
7 | 13 | 45.24 | 20 | 15.01 | 371 | 111 | 3.48 / 854.05 | 6 | 50 |
8 | 8 | 0.16 | 242 | 14.97 | 291 | 1054 | 4.53 / 855.11 | 6 | -99 |
Average= | 32.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 24 | 14.99 | 427 | 154 | 0.15 / 845.85 | 6 | 7 |
2 | 7 | 1606.04 | 40 | 14.64 | 2555 | 1496 | 1.65 / 847.35 | 7 | 49 |
3 | 13 | 1583.04 | 20 | 14.62 | 2526 | 739 | 2.39 / 848.08 | 5 | 52 |
4 | 13 | 1420.08 | 20 | 14.60 | 2307 | 674 | 3.06 / 848.76 | 5 | 56 |
5 | 13 | 898.96 | 20 | 14.71 | 1598 | 470 | 3.53 / 849.23 | 5 | 63 |
6 | 13 | 180.32 | 20 | 14.96 | 584 | 175 | 3.71 / 849.40 | 5 | 56 |
7 | 13 | 37.32 | 20 | 15.01 | 367 | 110 | 3.82 / 849.51 | 6 | 47 |
8 | 8 | 0.04 | 244 | 14.98 | 291 | 1064 | 4.88 / 850.58 | 6 | -99 |
Average= | 34.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 24 | 15.00 | 430 | 155 | 0.15 / 840.36 | 6 | 8 |
2 | 7 | 2006.92 | 40 | 14.48 | 3088 | 1789 | 1.94 / 842.14 | 8 | 42 |
3 | 13 | 1983.68 | 20 | 14.46 | 3074 | 889 | 2.83 / 843.03 | 5 | 48 |
4 | 13 | 1490.56 | 20 | 14.52 | 2406 | 699 | 3.53 / 843.73 | 5 | 55 |
5 | 13 | 958.20 | 20 | 14.65 | 1686 | 494 | 4.03 / 844.23 | 5 | 63 |
6 | 13 | 323.32 | 20 | 14.89 | 798 | 238 | 4.26 / 844.46 | 5 | 64 |
7 | 13 | 89.72 | 20 | 14.98 | 445 | 133 | 4.40 / 844.60 | 6 | 55 |
8 | 8 | 0.04 | 248 | 14.96 | 296 | 1098 | 5.49 / 845.70 | 6 | 232 |
Average= | 35.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 24 | 15.00 | 440 | 158 | 0.16 / 835.18 | 6 | 6 |
2 | 7 | 1822.56 | 40 | 14.56 | 2836 | 1652 | 1.81 / 836.83 | 6 | 44 |
3 | 13 | 1714.68 | 20 | 14.56 | 2708 | 789 | 2.60 / 837.62 | 5 | 50 |
4 | 13 | 1403.32 | 20 | 14.57 | 2288 | 667 | 3.27 / 838.28 | 5 | 57 |
5 | 13 | 972.56 | 20 | 14.66 | 1702 | 499 | 3.76 / 838.78 | 5 | 62 |
6 | 13 | 277.08 | 20 | 14.92 | 726 | 217 | 3.98 / 839.00 | 5 | 61 |
7 | 13 | 86.44 | 20 | 14.99 | 436 | 131 | 4.11 / 839.13 | 6 | 48 |
8 | 8 | 0.12 | 246 | 14.98 | 291 | 1072 | 5.18 / 840.20 | 6 | 191 |
Average= | 36.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 24 | 14.99 | 433 | 156 | 0.16 / 829.51 | 6 | 6 |
2 | 7 | 2010.32 | 40 | 14.50 | 3100 | 1798 | 1.95 / 831.30 | 6 | 42 |
3 | 13 | 1981.92 | 20 | 14.47 | 3061 | 886 | 2.84 / 832.19 | 5 | 46 |
4 | 13 | 1664.44 | 20 | 14.48 | 2631 | 762 | 3.60 / 832.95 | 5 | 51 |
5 | 13 | 1062.20 | 20 | 14.62 | 1827 | 534 | 4.14 / 833.49 | 5 | 63 |
6 | 13 | 426.24 | 20 | 14.85 | 948 | 282 | 4.42 / 833.77 | 5 | 63 |
7 | 13 | 110.52 | 20 | 14.97 | 483 | 145 | 4.56 / 833.91 | 5 | 59 |
8 | 8 | 0.00 | 250 | 14.97 | 295 | 1104 | 5.67 / 835.02 | 6 | -99 |
Average= | 37.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 25 | 14.99 | 435 | 163 | 0.16 / 823.77 | 6 | 7 |
2 | 3 | 1451.92 | -1 | 15.36 | 3 | 0 | 0.00 / 823.77 | 6 | 7 |
3 | 7 | 2015.32 | 40 | 14.50 | 3103 | 1800 | 1.96 / 825.57 | 7 | 43 |
4 | 13 | 1988.64 | 20 | 14.47 | 3063 | 886 | 2.85 / 826.46 | 5 | 45 |
5 | 13 | 1614.64 | 20 | 14.50 | 2571 | 746 | 3.59 / 827.20 | 5 | 51 |
6 | 13 | 1165.80 | 20 | 14.59 | 1971 | 575 | 4.17 / 827.78 | 5 | 60 |
7 | 13 | 543.12 | 20 | 14.80 | 1109 | 328 | 4.50 / 828.10 | 5 | 63 |
8 | 13 | 93.44 | 20 | 14.98 | 455 | 136 | 4.63 / 828.24 | 5 | 46 |
9 | 8 | 0.00 | 248 | 14.97 | 299 | 1110 | 5.74 / 829.35 | 6 | 219 |
Average= | 39.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 10 | 1508.88 | 8 | 14.69 | 2423 | 285 | 0.28 / 817.25 | 5 | 27 |
2 | 10 | 1523.88 | 7 | 14.67 | 2440 | 251 | 0.54 / 817.50 | 5 | 31 |
3 | 10 | 1536.48 | 6 | 14.66 | 2457 | 216 | 0.75 / 817.72 | 5 | 33 |
4 | 10 | 1546.00 | 4 | 14.67 | 2479 | 145 | 0.90 / 817.87 | 5 | 33 |
5 | 10 | 1552.12 | 3 | 14.67 | 2485 | 109 | 1.01 / 817.97 | 5 | 35 |
6 | 3 | 1551.00 | 1 | 14.77 | 2505 | 37 | 1.04 / 818.01 | 5 | 45 |
7 | 7 | 2012.36 | 40 | 14.48 | 3097 | 1794 | 2.84 / 819.81 | 45 | 44 |
8 | 13 | 1984.24 | 20 | 14.46 | 3065 | 886 | 3.72 / 820.69 | 5 | 44 |
9 | 13 | 1673.84 | 20 | 14.47 | 2649 | 767 | 4.49 / 821.46 | 5 | 51 |
10 | 13 | 1141.92 | 20 | 14.60 | 1935 | 565 | 5.06 / 822.02 | 5 | 59 |
11 | 13 | 498.96 | 20 | 14.82 | 1051 | 312 | 5.37 / 822.34 | 5 | 67 |
12 | 13 | 77.88 | 20 | 14.98 | 441 | 132 | 5.50 / 822.47 | 5 | 57 |
13 | 8 | 0.08 | 248 | 14.96 | 307 | 1139 | 6.64 / 823.61 | 6 | 131 |
Average= | 41.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 50 | 14.98 | 424 | 318 | 0.32 / 813.22 | 6 | 8 |
2 | 7 | 1025.24 | 40 | 14.92 | 1752 | 1046 | 1.36 / 814.27 | 8 | 45 |
3 | 13 | 1024.96 | 20 | 14.90 | 1754 | 523 | 1.89 / 814.79 | 5 | 49 |
4 | 13 | 999.20 | 20 | 14.86 | 1720 | 511 | 2.40 / 815.30 | 5 | 50 |
5 | 13 | 679.08 | 20 | 14.88 | 1288 | 383 | 2.78 / 815.68 | 5 | 57 |
6 | 13 | 98.24 | 20 | 15.03 | 468 | 141 | 2.92 / 815.82 | 5 | 58 |
7 | 8 | 0.16 | 255 | 15.01 | 299 | 1144 | 4.07 / 816.97 | 6 | 133 |
Average= | 43.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 50 | 14.98 | 433 | 324 | 0.32 / 809.08 | 6 | 11 |
2 | 7 | 1023.00 | 40 | 14.93 | 1751 | 1046 | 1.37 / 810.12 | 11 | 44 |
3 | 13 | 1028.48 | 20 | 14.90 | 1762 | 525 | 1.90 / 810.65 | 5 | 45 |
4 | 13 | 1003.48 | 20 | 14.86 | 1724 | 512 | 2.41 / 811.16 | 5 | 50 |
5 | 13 | 779.36 | 20 | 14.86 | 1431 | 425 | 2.83 / 811.58 | 5 | 56 |
6 | 13 | 126.56 | 20 | 15.02 | 509 | 153 | 2.99 / 811.74 | 5 | 60 |
7 | 13 | 29.56 | 20 | 15.05 | 362 | 109 | 3.09 / 811.85 | 6 | 56 |
8 | 8 | 0.04 | 235 | 15.00 | 300 | 1057 | 4.15 / 812.90 | 6 | 221 |
Average= | 45.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 50 | 14.99 | 422 | 316 | 0.32 / 805.05 | 6 | 9 |
2 | 7 | 985.20 | 40 | 14.91 | 1702 | 1015 | 1.33 / 806.07 | 9 | 54 |
3 | 13 | 984.12 | 20 | 14.88 | 1711 | 509 | 1.84 / 806.58 | 5 | 52 |
4 | 13 | 961.00 | 20 | 14.84 | 1682 | 499 | 2.34 / 807.08 | 5 | 57 |
5 | 13 | 595.96 | 20 | 14.89 | 1178 | 351 | 2.69 / 807.43 | 5 | 65 |
6 | 13 | 93.48 | 20 | 15.03 | 460 | 138 | 2.83 / 807.57 | 5 | 52 |
7 | 13 | 32.04 | 20 | 15.04 | 368 | 111 | 2.94 / 807.68 | 6 | 54 |
8 | 8 | 0.12 | 233 | 15.00 | 307 | 1073 | 4.01 / 808.75 | 6 | -99 |
Average= | 47.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 43 | 14.97 | 436 | 281 | 0.28 / 801.45 | 6 | 10 |
2 | 10 | 504.12 | 4 | 15.04 | 1022 | 61 | 0.34 / 801.51 | 6 | 26 |
3 | 10 | 510.56 | 3 | 15.04 | 1027 | 46 | 0.39 / 801.56 | 6 | 27 |
4 | 3 | 523.84 | 1 | 15.11 | 1080 | 16 | 0.40 / 801.58 | 5 | 39 |
5 | 7 | 713.52 | 40 | 15.03 | 1330 | 800 | 1.20 / 802.38 | 39 | 53 |
6 | 13 | 712.72 | 20 | 15.01 | 1333 | 400 | 1.60 / 802.78 | 5 | 53 |
7 | 13 | 692.96 | 20 | 14.98 | 1303 | 390 | 1.99 / 803.17 | 5 | 55 |
8 | 13 | 517.28 | 20 | 14.98 | 1064 | 319 | 2.31 / 803.49 | 5 | 60 |
9 | 13 | 62.40 | 20 | 15.07 | 414 | 125 | 2.44 / 803.61 | 5 | 55 |
10 | 8 | 0.04 | 250 | 15.03 | 300 | 1127 | 3.57 / 804.74 | 6 | -99 |
Average= | 50.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 734.48 | -12 | 15.32 | 3 | 0 | 0.00 / 797.90 | 6 | 6 |
2 | 7 | 733.72 | 40 | 15.00 | 1364 | 818 | 0.82 / 798.72 | 6 | 54 |
3 | 13 | 732.88 | 20 | 14.98 | 1372 | 411 | 1.23 / 799.13 | 5 | 57 |
4 | 13 | 713.04 | 20 | 14.95 | 1344 | 402 | 1.63 / 799.53 | 5 | 60 |
5 | 13 | 574.68 | 20 | 14.95 | 1148 | 343 | 1.98 / 799.87 | 5 | 64 |
6 | 13 | 102.92 | 20 | 15.04 | 482 | 145 | 2.12 / 800.02 | 5 | 61 |
7 | 8 | 0.08 | 250 | 15.01 | 308 | 1156 | 3.28 / 801.17 | 6 | -99 |
Average= | 53.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 741.36 | -12 | 15.32 | 3 | 0 | 0.00 / 794.53 | 6 | 6 |
2 | 7 | 780.20 | 40 | 14.98 | 1433 | 859 | 0.86 / 795.38 | 6 | 54 |
3 | 13 | 779.20 | 20 | 14.96 | 1430 | 428 | 1.29 / 795.81 | 5 | 55 |
4 | 13 | 752.92 | 20 | 14.93 | 1394 | 416 | 1.70 / 796.23 | 5 | 57 |
5 | 13 | 623.64 | 20 | 14.93 | 1218 | 364 | 2.07 / 796.59 | 5 | 63 |
6 | 13 | 77.32 | 20 | 15.05 | 438 | 132 | 2.20 / 796.72 | 5 | 58 |
7 | 13 | 21.28 | 20 | 15.06 | 352 | 106 | 2.30 / 796.83 | 6 | 54 |
8 | 8 | 0.00 | 231 | 15.01 | 308 | 1068 | 3.37 / 797.90 | 6 | 201 |
Average= | 56.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 799.00 | -11 | 15.32 | 3 | 0 | 0.00 / 791.19 | 6 | 6 |
2 | 7 | 799.00 | 40 | 14.98 | 1450 | 869 | 0.87 / 792.06 | 6 | 56 |
3 | 13 | 798.08 | 20 | 14.95 | 1458 | 436 | 1.31 / 792.49 | 5 | 57 |
4 | 13 | 776.64 | 20 | 14.92 | 1422 | 424 | 1.73 / 792.92 | 5 | 59 |
5 | 13 | 504.80 | 20 | 14.94 | 1063 | 318 | 2.05 / 793.24 | 5 | 61 |
6 | 13 | 77.84 | 20 | 15.05 | 436 | 131 | 2.18 / 793.37 | 5 | 54 |
7 | 13 | 23.36 | 20 | 15.06 | 347 | 105 | 2.28 / 793.47 | 6 | 56 |
8 | 8 | 0.04 | 231 | 15.01 | 304 | 1054 | 3.34 / 794.53 | 6 | 207 |
Average= | 61.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 774.00 | -11 | 15.33 | 3 | 0 | 0.00 / 787.86 | 6 | 6 |
2 | 7 | 774.16 | 40 | 14.98 | 1416 | 848 | 0.85 / 788.71 | 6 | 57 |
3 | 13 | 773.16 | 20 | 14.96 | 1422 | 425 | 1.27 / 789.13 | 5 | 60 |
4 | 13 | 756.36 | 20 | 14.93 | 1396 | 417 | 1.69 / 789.55 | 5 | 60 |
5 | 13 | 548.96 | 20 | 14.94 | 1113 | 333 | 2.02 / 789.88 | 5 | 65 |
6 | 13 | 85.88 | 20 | 15.04 | 456 | 137 | 2.16 / 790.02 | 5 | 66 |
7 | 13 | 27.08 | 20 | 15.05 | 360 | 108 | 2.27 / 790.13 | 5 | 57 |
8 | 8 | 0.04 | 229 | 15.00 | 309 | 1061 | 3.33 / 791.19 | 6 | 151 |
Average= | 65.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 793.88 | -11 | 15.32 | 3 | 0 | 0.00 / 784.50 | 6 | 6 |
2 | 7 | 804.08 | 41 | 14.97 | 1461 | 897 | 0.90 / 785.40 | 6 | 57 |
3 | 13 | 803.16 | 20 | 14.95 | 1453 | 434 | 1.33 / 785.83 | 5 | 57 |
4 | 13 | 779.28 | 20 | 14.92 | 1431 | 427 | 1.76 / 786.26 | 5 | 59 |
5 | 13 | 534.20 | 20 | 14.94 | 1093 | 327 | 2.09 / 786.58 | 5 | 66 |
6 | 13 | 73.92 | 20 | 15.05 | 431 | 130 | 2.22 / 786.71 | 5 | 55 |
7 | 13 | 21.24 | 20 | 15.06 | 347 | 105 | 2.32 / 786.82 | 6 | 56 |
8 | 8 | 0.04 | 231 | 15.01 | 300 | 1040 | 3.36 / 787.86 | 6 | 188 |
Average= | 71.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 818.04 | -11 | 15.32 | 3 | 0 | 0.00 / 781.00 | 6 | 6 |
2 | 7 | 843.60 | 40 | 14.96 | 1515 | 907 | 0.91 / 781.90 | 6 | 56 |
3 | 13 | 838.36 | 20 | 14.93 | 1515 | 452 | 1.36 / 782.35 | 5 | 57 |
4 | 13 | 808.56 | 20 | 14.90 | 1468 | 437 | 1.80 / 782.79 | 5 | 61 |
5 | 13 | 632.60 | 20 | 14.91 | 1226 | 366 | 2.16 / 783.16 | 5 | 62 |
6 | 13 | 107.88 | 20 | 15.03 | 490 | 147 | 2.31 / 783.31 | 5 | 59 |
7 | 13 | 38.52 | 20 | 15.04 | 380 | 114 | 2.42 / 783.42 | 6 | 56 |
8 | 8 | 0.04 | 233 | 15.00 | 309 | 1080 | 3.50 / 784.50 | 6 | 216 |
Average= | 78.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 843.56 | -10 | 15.33 | 3 | 0 | 0.00 / 777.56 | 6 | 6 |
2 | 7 | 841.24 | 40 | 14.96 | 1516 | 907 | 0.91 / 778.46 | 6 | 58 |
3 | 13 | 839.76 | 20 | 14.94 | 1515 | 453 | 1.36 / 778.92 | 5 | 55 |
4 | 13 | 818.44 | 20 | 14.90 | 1478 | 440 | 1.80 / 779.36 | 5 | 59 |
5 | 13 | 546.88 | 20 | 14.92 | 1105 | 330 | 2.13 / 779.69 | 5 | 65 |
6 | 13 | 85.48 | 20 | 15.04 | 452 | 136 | 2.27 / 779.82 | 5 | 59 |
7 | 13 | 25.92 | 20 | 15.05 | 360 | 108 | 2.37 / 779.93 | 6 | 53 |
8 | 8 | 0.08 | 231 | 15.00 | 307 | 1064 | 3.44 / 781.00 | 6 | 161 |
Average= | 86.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 886.40 | -10 | 15.34 | 2 | 0 | 0.00 / 773.96 | 6 | 6 |
2 | 7 | 886.60 | 40 | 14.94 | 1571 | 939 | 0.94 / 774.90 | 6 | 55 |
3 | 13 | 885.60 | 20 | 14.91 | 1578 | 471 | 1.41 / 775.37 | 5 | 56 |
4 | 13 | 863.44 | 20 | 14.88 | 1549 | 461 | 1.87 / 775.83 | 5 | 58 |
5 | 13 | 694.92 | 20 | 14.88 | 1326 | 395 | 2.27 / 776.22 | 5 | 65 |
6 | 13 | 140.64 | 20 | 15.02 | 534 | 160 | 2.43 / 776.38 | 5 | 55 |
7 | 13 | 34.04 | 20 | 15.04 | 371 | 112 | 2.54 / 776.49 | 6 | 56 |
8 | 8 | 0.16 | 231 | 15.00 | 307 | 1064 | 3.60 / 777.56 | 6 | 170 |
Average= | 97.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 935.88 | -9 | 15.33 | 2 | 0 | 0.00 / 770.35 | 6 | 6 |
2 | 7 | 936.08 | 40 | 14.92 | 1646 | 982 | 0.98 / 771.33 | 6 | 55 |
3 | 13 | 935.00 | 20 | 14.90 | 1647 | 491 | 1.47 / 771.83 | 5 | 57 |
4 | 13 | 912.36 | 20 | 14.86 | 1613 | 479 | 1.95 / 772.31 | 5 | 59 |
5 | 13 | 634.56 | 20 | 14.89 | 1235 | 368 | 2.32 / 772.67 | 5 | 62 |
6 | 13 | 66.44 | 20 | 15.04 | 414 | 125 | 2.45 / 772.80 | 6 | 54 |
7 | 13 | 21.72 | 20 | 15.05 | 345 | 104 | 2.55 / 772.90 | 6 | 54 |
8 | 8 | 0.08 | 233 | 15.00 | 302 | 1055 | 3.60 / 773.96 | 6 | 179 |
Average= | 110.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 865.32 | -10 | 15.33 | 3 | 0 | 0.00 / 766.85 | 6 | 6 |
2 | 7 | 865.96 | 40 | 14.95 | 1544 | 923 | 0.92 / 767.77 | 6 | 55 |
3 | 13 | 865.24 | 20 | 14.93 | 1550 | 463 | 1.39 / 768.23 | 5 | 57 |
4 | 13 | 845.48 | 20 | 14.90 | 1520 | 453 | 1.84 / 768.69 | 5 | 59 |
5 | 13 | 537.52 | 20 | 14.93 | 1097 | 328 | 2.17 / 769.01 | 5 | 64 |
6 | 13 | 111.08 | 20 | 15.03 | 490 | 147 | 2.31 / 769.16 | 5 | 58 |
7 | 13 | 40.72 | 20 | 15.05 | 382 | 115 | 2.43 / 769.28 | 5 | 57 |
8 | 8 | 0.04 | 233 | 15.00 | 308 | 1076 | 3.51 / 770.35 | 6 | -99 |
Average= | 128.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 841.40 | -10 | 15.33 | 3 | 0 | 0.00 / 762.93 | 6 | 6 |
2 | 7 | 841.60 | 40 | 14.96 | 1511 | 904 | 0.90 / 763.84 | 6 | 54 |
3 | 13 | 840.64 | 20 | 14.94 | 1522 | 455 | 1.36 / 764.29 | 5 | 58 |
4 | 13 | 840.64 | 20 | 14.90 | 1519 | 453 | 1.81 / 764.74 | 5 | 59 |
5 | 13 | 840.60 | 20 | 14.86 | 1512 | 449 | 2.26 / 765.19 | 5 | 61 |
6 | 13 | 840.60 | 20 | 14.81 | 1517 | 449 | 2.71 / 765.64 | 5 | 62 |
7 | 13 | 37.88 | 20 | 15.04 | 383 | 115 | 2.83 / 765.76 | 6 | 60 |
8 | 8 | 0.08 | 235 | 15.00 | 309 | 1089 | 3.92 / 766.85 | 6 | 230 |
Average= | 153.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 840.96 | -10 | 15.33 | 2 | 0 | 0.00 / 759.40 | 6 | 6 |
2 | 7 | 867.00 | 40 | 14.95 | 1545 | 924 | 0.92 / 760.32 | 6 | 57 |
3 | 13 | 866.04 | 20 | 14.93 | 1551 | 463 | 1.39 / 760.79 | 5 | 60 |
4 | 13 | 846.96 | 20 | 14.89 | 1522 | 453 | 1.84 / 761.24 | 5 | 58 |
5 | 13 | 638.72 | 20 | 14.90 | 1235 | 368 | 2.21 / 761.61 | 5 | 66 |
6 | 13 | 98.76 | 20 | 15.03 | 471 | 142 | 2.35 / 761.75 | 5 | 61 |
7 | 13 | 33.08 | 20 | 15.05 | 370 | 111 | 2.46 / 761.86 | 6 | 54 |
8 | 8 | 0.12 | 233 | 15.00 | 307 | 1073 | 3.53 / 762.93 | 6 | -99 |
Average= | 190.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 841.48 | -10 | 15.33 | 3 | 0 | 0.00 / 755.95 | 6 | 6 |
2 | 7 | 842.08 | 40 | 14.95 | 1517 | 907 | 0.91 / 756.86 | 6 | 60 |
3 | 13 | 840.92 | 20 | 14.94 | 1513 | 452 | 1.36 / 757.31 | 5 | 58 |
4 | 13 | 819.16 | 20 | 14.90 | 1477 | 440 | 1.80 / 757.75 | 5 | 59 |
5 | 13 | 541.36 | 20 | 14.93 | 1094 | 327 | 2.13 / 758.08 | 5 | 65 |
6 | 13 | 78.32 | 20 | 15.04 | 445 | 134 | 2.26 / 758.21 | 5 | 60 |
7 | 13 | 25.32 | 20 | 15.05 | 363 | 109 | 2.37 / 758.32 | 6 | 60 |
8 | 8 | 0.08 | 231 | 15.00 | 311 | 1078 | 3.45 / 759.40 | 6 | -99 |
Average= | 253.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 858.24 | -10 | 15.34 | 3 | 0 | 0.00 / 752.43 | 6 | 6 |
2 | 7 | 869.16 | 41 | 14.94 | 1554 | 952 | 0.95 / 753.38 | 6 | 59 |
3 | 13 | 868.16 | 20 | 14.92 | 1556 | 464 | 1.42 / 753.85 | 5 | 57 |
4 | 13 | 848.52 | 20 | 14.89 | 1523 | 454 | 1.87 / 754.30 | 5 | 63 |
5 | 13 | 535.92 | 20 | 14.92 | 1098 | 328 | 2.20 / 754.63 | 5 | 66 |
6 | 13 | 79.68 | 20 | 15.04 | 449 | 135 | 2.33 / 754.76 | 5 | 64 |
7 | 13 | 27.08 | 20 | 15.05 | 365 | 110 | 2.44 / 754.87 | 6 | 55 |
8 | 8 | 0.20 | 231 | 15.00 | 311 | 1078 | 3.52 / 755.95 | 6 | -99 |
Average= | 377.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 893.44 | -9 | 15.33 | 3 | 0 | 0.00 / 748.82 | 6 | 6 |
2 | 7 | 893.76 | 40 | 14.94 | 1587 | 948 | 0.95 / 749.77 | 6 | 57 |
3 | 13 | 892.76 | 20 | 14.92 | 1584 | 473 | 1.42 / 750.24 | 5 | 57 |
4 | 13 | 872.56 | 20 | 14.88 | 1561 | 465 | 1.89 / 750.71 | 5 | 60 |
5 | 13 | 665.84 | 20 | 14.89 | 1280 | 381 | 2.27 / 751.09 | 5 | 61 |
6 | 13 | 114.88 | 20 | 15.03 | 499 | 150 | 2.42 / 751.24 | 5 | 60 |
7 | 13 | 46.04 | 20 | 15.05 | 393 | 118 | 2.54 / 751.36 | 6 | 55 |
8 | 8 | 0.00 | 233 | 15.00 | 308 | 1076 | 3.61 / 752.43 | 6 | 140 |
Average= | 752.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 948.24 | -9 | 15.34 | 3 | 0 | 0.00 / 745.16 | 6 | 6 |
2 | 7 | 947.72 | 40 | 14.91 | 1657 | 988 | 0.99 / 746.15 | 6 | 57 |
3 | 13 | 946.60 | 20 | 14.89 | 1661 | 495 | 1.48 / 746.64 | 5 | 57 |
4 | 13 | 933.12 | 20 | 14.85 | 1641 | 487 | 1.97 / 747.13 | 5 | 59 |
5 | 13 | 627.52 | 20 | 14.88 | 1225 | 365 | 2.34 / 747.49 | 5 | 64 |
6 | 13 | 136.00 | 20 | 15.02 | 523 | 157 | 2.49 / 747.65 | 5 | 55 |
7 | 13 | 38.36 | 20 | 15.05 | 369 | 111 | 2.60 / 747.76 | 6 | 47 |
8 | 8 | 0.00 | 235 | 15.00 | 300 | 1057 | 3.66 / 748.82 | 6 | 178 |
Average= | 74.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 961.08 | -8 | 15.34 | 3 | 0 | 0.00 / 741.44 | 6 | 6 |
2 | 7 | 969.44 | 40 | 14.90 | 1685 | 1004 | 1.00 / 742.45 | 6 | 53 |
3 | 13 | 968.32 | 20 | 14.88 | 1689 | 503 | 1.51 / 742.95 | 5 | 57 |
4 | 13 | 944.64 | 20 | 14.85 | 1660 | 493 | 2.00 / 743.44 | 5 | 60 |
5 | 13 | 703.76 | 20 | 14.86 | 1333 | 396 | 2.40 / 743.84 | 5 | 64 |
6 | 13 | 121.32 | 20 | 15.03 | 506 | 152 | 2.55 / 743.99 | 5 | 56 |
7 | 13 | 27.28 | 20 | 15.05 | 356 | 107 | 2.66 / 744.10 | 6 | 53 |
8 | 8 | 0.04 | 235 | 15.01 | 301 | 1062 | 3.72 / 745.16 | 6 | 218 |
Average= | 82.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 989.60 | -8 | 15.35 | 3 | 0 | 0.00 / 737.67 | 6 | 6 |
2 | 7 | 989.28 | 40 | 14.90 | 1721 | 1026 | 1.03 / 738.70 | 6 | 55 |
3 | 13 | 988.16 | 20 | 14.88 | 1708 | 508 | 1.53 / 739.21 | 5 | 58 |
4 | 13 | 969.72 | 20 | 14.84 | 1697 | 504 | 2.04 / 739.71 | 5 | 59 |
5 | 13 | 727.12 | 20 | 14.85 | 1368 | 406 | 2.44 / 740.12 | 5 | 62 |
6 | 13 | 141.36 | 20 | 15.02 | 529 | 159 | 2.60 / 740.27 | 5 | 55 |
7 | 13 | 39.32 | 20 | 15.05 | 366 | 110 | 2.71 / 740.38 | 6 | 47 |
8 | 8 | 0.04 | 235 | 15.01 | 300 | 1058 | 3.77 / 741.44 | 6 | 189 |
Average= | 92.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1039.80 | -7 | 15.35 | 3 | 0 | 0.00 / 733.89 | 6 | 6 |
2 | 7 | 1038.84 | 40 | 14.86 | 1791 | 1065 | 1.06 / 734.95 | 6 | 58 |
3 | 13 | 1033.08 | 20 | 14.85 | 1778 | 528 | 1.59 / 735.48 | 5 | 57 |
4 | 13 | 1007.72 | 20 | 14.81 | 1751 | 519 | 2.11 / 736.00 | 5 | 60 |
5 | 13 | 617.20 | 20 | 14.87 | 1211 | 360 | 2.47 / 736.36 | 5 | 68 |
6 | 13 | 121.44 | 20 | 15.03 | 493 | 148 | 2.62 / 736.51 | 5 | 49 |
7 | 13 | 54.32 | 20 | 15.04 | 391 | 118 | 2.74 / 736.63 | 6 | 54 |
8 | 8 | 0.00 | 235 | 15.01 | 296 | 1044 | 3.78 / 737.67 | 6 | -99 |
Average= | 105.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 973.76 | -8 | 15.35 | 3 | 0 | 0.00 / 730.19 | 6 | 6 |
2 | 7 | 1000.92 | 40 | 14.89 | 1741 | 1037 | 1.04 / 731.22 | 6 | 56 |
3 | 13 | 999.80 | 20 | 14.87 | 1739 | 517 | 1.55 / 731.74 | 5 | 57 |
4 | 13 | 978.48 | 20 | 14.83 | 1709 | 507 | 2.06 / 732.25 | 5 | 58 |
5 | 13 | 552.96 | 20 | 14.90 | 1126 | 336 | 2.40 / 732.58 | 5 | 64 |
6 | 13 | 108.88 | 20 | 15.04 | 477 | 143 | 2.54 / 732.73 | 6 | 50 |
7 | 13 | 42.96 | 20 | 15.05 | 372 | 112 | 2.65 / 732.84 | 6 | 49 |
8 | 8 | 0.00 | 235 | 15.01 | 298 | 1051 | 3.70 / 733.89 | 6 | -99 |
Average= | 122.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 963.00 | -8 | 15.35 | 3 | 0 | 0.00 / 726.54 | 6 | 6 |
2 | 7 | 963.16 | 40 | 14.91 | 1685 | 1005 | 1.01 / 727.54 | 6 | 58 |
3 | 13 | 961.92 | 20 | 14.89 | 1688 | 503 | 1.51 / 728.05 | 5 | 55 |
4 | 13 | 938.12 | 20 | 14.85 | 1654 | 491 | 2.00 / 728.54 | 5 | 60 |
5 | 13 | 627.96 | 20 | 14.89 | 1230 | 366 | 2.37 / 728.91 | 5 | 68 |
6 | 13 | 126.56 | 20 | 15.04 | 495 | 149 | 2.51 / 729.05 | 6 | 39 |
7 | 13 | 30.92 | 20 | 15.06 | 350 | 105 | 2.62 / 729.16 | 6 | 38 |
8 | 8 | 0.08 | 235 | 15.02 | 291 | 1027 | 3.65 / 730.19 | 6 | -99 |
Average= | 146.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 957.20 | -8 | 15.35 | 3 | 0 | 0.00 / 722.87 | 6 | 6 |
2 | 7 | 952.56 | 40 | 14.91 | 1670 | 996 | 1.00 / 723.86 | 6 | 59 |
3 | 13 | 951.48 | 20 | 14.89 | 1676 | 499 | 1.50 / 724.36 | 5 | 59 |
4 | 13 | 929.76 | 20 | 14.85 | 1639 | 487 | 1.98 / 724.85 | 5 | 60 |
5 | 13 | 652.72 | 20 | 14.88 | 1258 | 374 | 2.36 / 725.22 | 5 | 63 |
6 | 13 | 140.24 | 20 | 15.03 | 525 | 158 | 2.51 / 725.38 | 6 | 54 |
7 | 13 | 35.40 | 20 | 15.06 | 362 | 109 | 2.62 / 725.49 | 6 | 47 |
8 | 8 | 0.08 | 235 | 15.02 | 297 | 1048 | 3.67 / 726.54 | 6 | -99 |
Average= | 181.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 971.44 | -8 | 15.35 | 3 | 0 | 0.00 / 719.16 | 6 | 6 |
2 | 7 | 971.12 | 40 | 14.91 | 1697 | 1012 | 1.01 / 720.18 | 6 | 58 |
3 | 13 | 967.32 | 20 | 14.89 | 1694 | 504 | 1.52 / 720.68 | 5 | 59 |
4 | 13 | 941.64 | 20 | 14.85 | 1658 | 492 | 2.01 / 721.17 | 5 | 61 |
5 | 13 | 659.08 | 20 | 14.88 | 1273 | 379 | 2.39 / 721.55 | 5 | 66 |
6 | 13 | 113.72 | 20 | 15.04 | 490 | 147 | 2.54 / 721.70 | 5 | 49 |
7 | 13 | 44.32 | 20 | 15.06 | 377 | 114 | 2.65 / 721.81 | 6 | 50 |
8 | 8 | 0.08 | 235 | 15.02 | 299 | 1055 | 3.70 / 722.87 | 6 | -99 |
Average= | 240.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1082.92 | -7 | 15.36 | 3 | 0 | 0.00 / 715.30 | 6 | 6 |
2 | 7 | 1082.80 | 40 | 14.86 | 1846 | 1097 | 1.10 / 716.40 | 6 | 57 |
3 | 13 | 1081.56 | 20 | 14.83 | 1846 | 548 | 1.65 / 716.94 | 5 | 59 |
4 | 13 | 1056.44 | 20 | 14.80 | 1813 | 537 | 2.18 / 717.48 | 5 | 62 |
5 | 13 | 631.04 | 20 | 14.87 | 1232 | 366 | 2.55 / 717.85 | 5 | 64 |
6 | 13 | 97.64 | 20 | 15.04 | 466 | 140 | 2.69 / 717.99 | 6 | 53 |
7 | 13 | 33.60 | 20 | 15.05 | 362 | 109 | 2.80 / 718.10 | 6 | 46 |
8 | 8 | 0.04 | 235 | 15.01 | 303 | 1069 | 3.87 / 719.16 | 6 | -99 |
Average= | 359.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1190.92 | -5 | 15.36 | 3 | 0 | 0.00 / 711.20 | 6 | 6 |
2 | 7 | 1189.80 | 40 | 14.81 | 1995 | 1182 | 1.18 / 712.38 | 6 | 54 |
3 | 13 | 1175.16 | 20 | 14.79 | 1987 | 588 | 1.77 / 712.97 | 5 | 58 |
4 | 13 | 1147.48 | 20 | 14.75 | 1937 | 571 | 2.34 / 713.54 | 5 | 59 |
5 | 13 | 742.60 | 20 | 14.82 | 1387 | 411 | 2.75 / 713.95 | 5 | 66 |
6 | 13 | 120.68 | 20 | 15.02 | 499 | 150 | 2.90 / 714.10 | 5 | 50 |
7 | 13 | 52.24 | 20 | 15.04 | 395 | 119 | 3.02 / 714.22 | 6 | 51 |
8 | 8 | 0.04 | 238 | 15.01 | 301 | 1075 | 4.10 / 715.30 | 6 | -99 |
Average= | 715.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1102.04 | -6 | 15.35 | 3 | 0 | 0.00 / 707.19 | 6 | 6 |
2 | 7 | 1102.80 | 40 | 14.85 | 1875 | 1114 | 1.11 / 708.30 | 6 | 55 |
3 | 13 | 1101.52 | 20 | 14.83 | 1880 | 558 | 1.67 / 708.86 | 5 | 57 |
4 | 13 | 1077.48 | 20 | 14.79 | 1841 | 545 | 2.22 / 709.41 | 5 | 60 |
5 | 13 | 820.20 | 20 | 14.81 | 1496 | 443 | 2.66 / 709.85 | 5 | 69 |
6 | 13 | 147.96 | 20 | 15.02 | 544 | 163 | 2.82 / 710.01 | 5 | 60 |
7 | 13 | 42.84 | 20 | 15.05 | 379 | 114 | 2.94 / 710.13 | 6 | 57 |
8 | 8 | 0.08 | 238 | 15.01 | 301 | 1075 | 4.01 / 711.20 | 6 | -99 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1081.60 | -7 | 15.34 | 3 | 0 | 0.00 / 703.35 | 6 | 6 |
2 | 7 | 1081.92 | 40 | 14.86 | 1848 | 1098 | 1.10 / 704.45 | 6 | 56 |
3 | 13 | 1072.04 | 20 | 14.84 | 1832 | 544 | 1.64 / 705.00 | 5 | 59 |
4 | 13 | 1043.68 | 20 | 14.81 | 1787 | 529 | 2.17 / 705.53 | 5 | 60 |
5 | 13 | 581.04 | 20 | 14.89 | 1160 | 345 | 2.52 / 705.87 | 5 | 65 |
6 | 13 | 88.84 | 20 | 15.05 | 452 | 136 | 2.65 / 706.01 | 5 | 52 |
7 | 13 | 25.64 | 20 | 15.06 | 356 | 107 | 2.76 / 706.11 | 6 | 55 |
8 | 8 | 0.04 | 235 | 15.01 | 305 | 1076 | 3.84 / 707.19 | 6 | 226 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1096.96 | -6 | 15.35 | 3 | 0 | 0.00 / 699.41 | 6 | 6 |
2 | 7 | 1097.24 | 41 | 14.84 | 1870 | 1138 | 1.14 / 700.55 | 6 | 56 |
3 | 13 | 1095.96 | 20 | 14.83 | 1873 | 556 | 1.69 / 701.10 | 5 | 58 |
4 | 13 | 1070.88 | 20 | 14.78 | 1832 | 542 | 2.24 / 701.64 | 5 | 61 |
5 | 13 | 701.80 | 20 | 14.84 | 1333 | 396 | 2.63 / 702.04 | 5 | 66 |
6 | 13 | 56.44 | 20 | 15.05 | 406 | 122 | 2.75 / 702.16 | 5 | 52 |
7 | 13 | 14.84 | 20 | 15.06 | 341 | 103 | 2.86 / 702.27 | 6 | 54 |
8 | 8 | 0.08 | 235 | 15.00 | 309 | 1089 | 3.94 / 703.35 | 6 | -99 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1076.56 | -7 | 15.35 | 3 | 0 | 0.00 / 695.52 | 6 | 6 |
2 | 7 | 1076.76 | 40 | 14.86 | 1843 | 1095 | 1.10 / 696.61 | 6 | 57 |
3 | 13 | 1075.48 | 20 | 14.84 | 1845 | 548 | 1.64 / 697.16 | 5 | 61 |
4 | 13 | 1047.84 | 20 | 14.80 | 1806 | 535 | 2.18 / 697.70 | 5 | 63 |
5 | 13 | 687.52 | 20 | 14.86 | 1309 | 389 | 2.57 / 698.09 | 5 | 68 |
6 | 13 | 135.48 | 20 | 15.03 | 520 | 156 | 2.72 / 698.24 | 5 | 59 |
7 | 13 | 15.36 | 20 | 15.06 | 336 | 101 | 2.82 / 698.34 | 6 | 52 |
8 | 8 | -0.04 | 233 | 15.01 | 305 | 1067 | 3.89 / 699.41 | 6 | 143 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1114.60 | -6 | 15.35 | 3 | 0 | 0.00 / 691.57 | 6 | 6 |
2 | 7 | 1114.24 | 40 | 14.84 | 1896 | 1125 | 1.13 / 692.70 | 6 | 59 |
3 | 13 | 1103.20 | 20 | 14.82 | 1882 | 558 | 1.68 / 693.26 | 5 | 63 |
4 | 13 | 1075.20 | 20 | 14.78 | 1844 | 545 | 2.23 / 693.80 | 5 | 61 |
5 | 13 | 687.28 | 20 | 14.85 | 1311 | 389 | 2.62 / 694.19 | 5 | 66 |
6 | 13 | 88.64 | 20 | 15.05 | 454 | 137 | 2.75 / 694.33 | 6 | 49 |
7 | 13 | 27.48 | 20 | 15.06 | 360 | 108 | 2.86 / 694.44 | 6 | 48 |
8 | 8 | 0.00 | 235 | 15.01 | 307 | 1083 | 3.95 / 695.52 | 6 | 212 |
Average= | 5.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1100.28 | -6 | 15.35 | 3 | 0 | 0.00 / 687.63 | 6 | 6 |
2 | 7 | 1102.56 | 40 | 14.86 | 1870 | 1112 | 1.11 / 688.74 | 6 | 54 |
3 | 13 | 1101.32 | 20 | 14.83 | 1872 | 555 | 1.67 / 689.30 | 5 | 58 |
4 | 13 | 1075.24 | 20 | 14.79 | 1837 | 543 | 2.21 / 689.84 | 5 | 61 |
5 | 13 | 708.16 | 20 | 14.85 | 1335 | 396 | 2.61 / 690.24 | 5 | 64 |
6 | 13 | 126.76 | 20 | 15.03 | 507 | 152 | 2.76 / 690.39 | 5 | 57 |
7 | 13 | 27.68 | 20 | 15.06 | 357 | 108 | 2.87 / 690.50 | 6 | 47 |
8 | 8 | -0.04 | 236 | 15.01 | 304 | 1077 | 3.94 / 691.57 | 6 | -99 |
Average= | 5.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1114.84 | -6 | 15.35 | 3 | 0 | 0.00 / 683.68 | 6 | 6 |
2 | 7 | 1134.64 | 40 | 14.84 | 1915 | 1137 | 1.14 / 684.82 | 6 | 56 |
3 | 13 | 1133.32 | 20 | 14.82 | 1914 | 567 | 1.70 / 685.39 | 5 | 56 |
4 | 13 | 1105.64 | 20 | 14.78 | 1877 | 555 | 2.26 / 685.94 | 5 | 61 |
5 | 13 | 665.68 | 20 | 14.86 | 1280 | 380 | 2.64 / 686.32 | 5 | 65 |
6 | 13 | 85.92 | 20 | 15.05 | 448 | 135 | 2.77 / 686.46 | 5 | 54 |
7 | 8 | 0.16 | 255 | 15.02 | 306 | 1172 | 3.95 / 687.63 | 6 | 237 |
Average= | 5.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1102.08 | -6 | 15.35 | 3 | 0 | 0.00 / 679.80 | 6 | 6 |
2 | 7 | 1124.88 | 40 | 14.85 | 1900 | 1129 | 1.13 / 680.93 | 6 | 54 |
3 | 13 | 1106.68 | 20 | 14.84 | 1879 | 558 | 1.69 / 681.48 | 5 | 57 |
4 | 13 | 1045.60 | 20 | 14.81 | 1792 | 531 | 2.22 / 682.02 | 5 | 59 |
5 | 13 | 613.28 | 20 | 14.88 | 1203 | 358 | 2.58 / 682.37 | 5 | 63 |
6 | 13 | 84.72 | 20 | 15.05 | 447 | 135 | 2.71 / 682.51 | 5 | 53 |
7 | 8 | 0.08 | 255 | 15.02 | 307 | 1176 | 3.89 / 683.68 | 6 | -99 |
Average= | 5.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1140.44 | -6 | 15.35 | 2 | 0 | 0.00 / 675.85 | 6 | 6 |
2 | 7 | 1140.48 | 40 | 14.84 | 1932 | 1147 | 1.15 / 677.00 | 6 | 57 |
3 | 13 | 1128.20 | 20 | 14.82 | 1916 | 568 | 1.71 / 677.57 | 5 | 59 |
4 | 13 | 1100.00 | 20 | 14.78 | 1868 | 552 | 2.27 / 678.12 | 5 | 63 |
5 | 13 | 561.32 | 20 | 14.89 | 1138 | 339 | 2.61 / 678.46 | 5 | 64 |
6 | 13 | 111.00 | 20 | 15.04 | 489 | 147 | 2.75 / 678.61 | 5 | 57 |
7 | 13 | 16.48 | 20 | 15.06 | 344 | 104 | 2.86 / 678.71 | 6 | 52 |
8 | 8 | -0.04 | 233 | 15.01 | 311 | 1088 | 3.94 / 679.80 | 6 | 222 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1160.72 | -5 | 15.36 | 3 | 0 | 0.00 / 671.86 | 6 | 6 |
2 | 7 | 1160.24 | 41 | 14.83 | 1954 | 1188 | 1.19 / 673.05 | 6 | 57 |
3 | 13 | 1146.28 | 20 | 14.81 | 1937 | 574 | 1.76 / 673.63 | 5 | 57 |
4 | 13 | 1118.80 | 20 | 14.77 | 1899 | 561 | 2.32 / 674.19 | 5 | 62 |
5 | 13 | 583.44 | 20 | 14.88 | 1168 | 348 | 2.67 / 674.53 | 5 | 69 |
6 | 13 | 91.32 | 20 | 15.04 | 458 | 138 | 2.81 / 674.67 | 5 | 57 |
7 | 8 | 0.08 | 255 | 15.01 | 309 | 1183 | 3.99 / 675.85 | 6 | -99 |
Average= | 5.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1207.32 | -5 | 15.36 | 3 | 0 | 0.00 / 667.78 | 6 | 6 |
2 | 7 | 1207.40 | 41 | 14.81 | 2021 | 1227 | 1.23 / 669.01 | 6 | 56 |
3 | 13 | 1192.68 | 20 | 14.79 | 2003 | 592 | 1.82 / 669.60 | 5 | 59 |
4 | 13 | 1162.76 | 20 | 14.75 | 1953 | 576 | 2.40 / 670.17 | 5 | 59 |
5 | 13 | 666.44 | 20 | 14.86 | 1277 | 380 | 2.78 / 670.55 | 5 | 65 |
6 | 13 | 91.92 | 20 | 15.05 | 451 | 136 | 2.91 / 670.69 | 6 | 49 |
7 | 8 | 0.08 | 257 | 15.02 | 304 | 1173 | 4.08 / 671.86 | 6 | -99 |
Average= | 5.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1274.20 | -4 | 15.36 | 3 | 0 | 0.00 / 663.48 | 6 | 6 |
2 | 7 | 1288.76 | 40 | 14.78 | 2131 | 1260 | 1.26 / 664.74 | 6 | 56 |
3 | 13 | 1272.56 | 20 | 14.76 | 2104 | 621 | 1.88 / 665.36 | 5 | 57 |
4 | 13 | 1243.00 | 20 | 14.72 | 2068 | 609 | 2.49 / 665.97 | 5 | 59 |
5 | 13 | 877.24 | 20 | 14.78 | 1575 | 466 | 2.96 / 666.43 | 5 | 68 |
6 | 13 | 147.20 | 20 | 15.03 | 537 | 161 | 3.12 / 666.59 | 6 | 54 |
7 | 13 | 18.16 | 20 | 15.07 | 339 | 102 | 3.22 / 666.70 | 6 | 50 |
8 | 8 | 0.04 | 238 | 15.02 | 303 | 1083 | 4.30 / 667.78 | 6 | 220 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 1290.92 | -3 | 15.36 | 3 | 0 | 0.00 / 659.20 | 6 | 6 |
2 | 7 | 1313.88 | 40 | 14.77 | 2161 | 1277 | 1.28 / 660.47 | 6 | 54 |
3 | 13 | 1291.60 | 20 | 14.76 | 2138 | 631 | 1.91 / 661.10 | 5 | 56 |
4 | 13 | 1261.68 | 20 | 14.72 | 2091 | 616 | 2.52 / 661.72 | 5 | 60 |
5 | 13 | 790.44 | 20 | 14.81 | 1457 | 432 | 2.96 / 662.15 | 5 | 65 |
6 | 13 | 132.08 | 20 | 15.03 | 522 | 157 | 3.11 / 662.31 | 5 | 55 |
7 | 8 | 0.16 | 257 | 15.02 | 303 | 1170 | 4.28 / 663.48 | 6 | 156 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 1 | 15.04 | 448 | 7 | 0.01 / 654.88 | 6 | 6 |
2 | 3 | 1309.56 | -3 | 15.36 | 3 | 0 | 0.00 / 654.88 | 6 | 6 |
3 | 7 | 1310.16 | 41 | 14.77 | 2157 | 1306 | 1.31 / 656.19 | 6 | 51 |
4 | 13 | 1292.20 | 20 | 14.76 | 2130 | 629 | 1.94 / 656.82 | 5 | 58 |
5 | 13 | 1262.52 | 20 | 14.71 | 2089 | 615 | 2.56 / 657.43 | 5 | 59 |
6 | 13 | 751.76 | 20 | 14.82 | 1403 | 416 | 2.97 / 657.85 | 5 | 64 |
7 | 13 | 146.56 | 20 | 15.02 | 542 | 163 | 3.13 / 658.01 | 5 | 53 |
8 | 8 | 0.00 | 257 | 15.02 | 307 | 1185 | 4.32 / 659.20 | 6 | 230 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 6 | 15.04 | 434 | 39 | 0.04 / 650.48 | 6 | 6 |
2 | 3 | 1387.48 | -2 | 15.37 | 3 | 0 | 0.00 / 650.48 | 6 | 6 |
3 | 7 | 1387.60 | 40 | 14.74 | 2255 | 1330 | 1.37 / 651.81 | 6 | 52 |
4 | 13 | 1367.80 | 20 | 14.73 | 2242 | 660 | 2.03 / 652.47 | 5 | 54 |
5 | 13 | 1304.68 | 20 | 14.69 | 2151 | 632 | 2.66 / 653.11 | 5 | 59 |
6 | 13 | 759.64 | 20 | 14.81 | 1414 | 419 | 3.08 / 653.53 | 5 | 69 |
7 | 13 | 129.12 | 20 | 15.03 | 511 | 154 | 3.23 / 653.68 | 5 | 53 |
8 | 8 | 0.16 | 257 | 15.01 | 310 | 1196 | 4.43 / 654.88 | 6 | 161 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 8 | 15.03 | 435 | 52 | 0.05 / 645.88 | 6 | 6 |
2 | 3 | 1460.96 | -1 | 15.36 | 3 | 0 | 0.00 / 645.88 | 6 | 6 |
3 | 7 | 1482.00 | 40 | 14.71 | 2392 | 1407 | 1.46 / 647.28 | 6 | 52 |
4 | 13 | 1459.92 | 20 | 14.69 | 2364 | 695 | 2.15 / 647.98 | 5 | 55 |
5 | 13 | 1361.92 | 20 | 14.67 | 2231 | 655 | 2.81 / 648.63 | 5 | 56 |
6 | 13 | 742.32 | 20 | 14.81 | 1394 | 413 | 3.22 / 649.05 | 5 | 67 |
7 | 13 | 179.64 | 20 | 15.00 | 597 | 179 | 3.40 / 649.23 | 5 | 60 |
8 | 13 | 32.36 | 20 | 15.05 | 370 | 111 | 3.51 / 649.34 | 6 | 55 |
9 | 8 | -0.04 | 240 | 15.00 | 308 | 1109 | 4.62 / 650.45 | 6 | -99 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 8 | 15.04 | 435 | 52 | 0.05 / 641.15 | 6 | 6 |
2 | 7 | 1497.20 | 40 | 14.71 | 2407 | 1416 | 1.47 / 642.57 | 6 | 52 |
3 | 13 | 1478.24 | 20 | 14.68 | 2392 | 702 | 2.17 / 643.27 | 5 | 54 |
4 | 13 | 1416.60 | 20 | 14.65 | 2303 | 675 | 2.85 / 643.94 | 5 | 55 |
5 | 13 | 925.88 | 20 | 14.75 | 1641 | 484 | 3.33 / 644.43 | 5 | 66 |
6 | 13 | 209.88 | 20 | 14.99 | 639 | 192 | 3.52 / 644.62 | 5 | 59 |
7 | 13 | 14.60 | 20 | 15.06 | 342 | 103 | 3.62 / 644.72 | 6 | 48 |
8 | 8 | 0.00 | 240 | 15.01 | 306 | 1102 | 4.73 / 645.82 | 6 | 151 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 13 | 15.03 | 433 | 85 | 0.08 / 636.63 | 6 | 6 |
2 | 3 | 1383.60 | -2 | 15.37 | 3 | 0 | 0.00 / 636.63 | 6 | 6 |
3 | 7 | 1383.76 | 40 | 14.75 | 2260 | 1333 | 1.42 / 637.96 | 6 | 55 |
4 | 13 | 1364.08 | 20 | 14.73 | 2237 | 659 | 2.08 / 638.62 | 5 | 55 |
5 | 13 | 1300.16 | 20 | 14.70 | 2149 | 632 | 2.71 / 639.25 | 5 | 58 |
6 | 13 | 893.20 | 20 | 14.77 | 1597 | 472 | 3.18 / 639.72 | 5 | 64 |
7 | 13 | 166.88 | 20 | 15.02 | 569 | 171 | 3.35 / 639.89 | 5 | 61 |
8 | 13 | 28.24 | 20 | 15.06 | 360 | 108 | 3.46 / 640.00 | 6 | 54 |
9 | 8 | 0.12 | 240 | 15.02 | 304 | 1096 | 4.56 / 641.10 | 6 | 209 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 18 | 15.02 | 447 | 121 | 0.12 / 632.09 | 6 | 7 |
2 | 3 | 1364.68 | -2 | 15.36 | 3 | 0 | 0.00 / 632.09 | 6 | 7 |
3 | 7 | 1374.92 | 41 | 14.75 | 2247 | 1359 | 1.48 / 633.44 | 7 | 55 |
4 | 13 | 1353.36 | 20 | 14.74 | 2214 | 653 | 2.13 / 634.10 | 5 | 56 |
5 | 13 | 1290.48 | 20 | 14.70 | 2129 | 626 | 2.76 / 634.72 | 5 | 60 |
6 | 13 | 843.52 | 20 | 14.79 | 1527 | 452 | 3.21 / 635.17 | 5 | 68 |
7 | 13 | 154.72 | 20 | 15.02 | 559 | 168 | 3.38 / 635.34 | 5 | 54 |
8 | 13 | 21.76 | 20 | 15.06 | 352 | 106 | 3.48 / 635.45 | 6 | 56 |
9 | 8 | -0.04 | 238 | 15.02 | 306 | 1094 | 4.58 / 636.54 | 6 | 202 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 23 | 15.02 | 433 | 150 | 0.15 / 627.42 | 6 | 9 |
2 | 3 | 1393.92 | -2 | 15.37 | 3 | 0 | 0.00 / 627.42 | 6 | 9 |
3 | 7 | 1479.84 | 40 | 14.71 | 2382 | 1402 | 1.55 / 628.82 | 9 | 53 |
4 | 13 | 1457.64 | 20 | 14.69 | 2356 | 692 | 2.24 / 629.51 | 5 | 53 |
5 | 13 | 1359.48 | 20 | 14.67 | 2228 | 654 | 2.90 / 630.17 | 5 | 57 |
6 | 13 | 803.16 | 20 | 14.79 | 1479 | 437 | 3.33 / 630.60 | 5 | 67 |
7 | 13 | 163.00 | 20 | 15.01 | 575 | 173 | 3.51 / 630.78 | 5 | 64 |
8 | 8 | -0.04 | 257 | 15.01 | 308 | 1188 | 4.70 / 631.96 | 6 | 136 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 12 | 15.03 | 435 | 78 | 0.08 / 622.13 | 6 | 6 |
2 | 10 | 1511.00 | 5 | 14.75 | 2431 | 179 | 0.26 / 622.31 | 5 | 34 |
3 | 10 | 1520.56 | 4 | 14.76 | 2449 | 145 | 0.40 / 622.46 | 5 | 34 |
4 | 10 | 1526.76 | 3 | 14.75 | 2469 | 109 | 0.51 / 622.57 | 5 | 35 |
5 | 3 | 1530.32 | 1 | 14.88 | 2475 | 37 | 0.55 / 622.60 | 5 | 39 |
6 | 7 | 1472.32 | 40 | 14.72 | 2378 | 1400 | 1.95 / 624.00 | 39 | 51 |
7 | 13 | 1451.60 | 20 | 14.69 | 2351 | 691 | 2.64 / 624.70 | 5 | 54 |
8 | 13 | 1389.08 | 20 | 14.66 | 2268 | 665 | 3.30 / 625.36 | 5 | 58 |
9 | 13 | 949.12 | 20 | 14.74 | 1675 | 494 | 3.80 / 625.85 | 5 | 67 |
10 | 13 | 256.16 | 20 | 14.98 | 709 | 212 | 4.01 / 626.07 | 5 | 65 |
11 | 13 | 31.80 | 20 | 15.06 | 367 | 111 | 4.12 / 626.18 | 6 | 49 |
12 | 8 | 0.08 | 240 | 15.01 | 303 | 1092 | 5.21 / 627.27 | 6 | 152 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 12 | 15.04 | 427 | 77 | 0.08 / 617.52 | 6 | 6 |
2 | 7 | 1473.84 | 40 | 14.71 | 2380 | 1400 | 1.48 / 618.92 | 6 | 51 |
3 | 13 | 1451.96 | 20 | 14.69 | 2353 | 691 | 2.17 / 619.61 | 5 | 56 |
4 | 13 | 1388.84 | 20 | 14.65 | 2262 | 663 | 2.83 / 620.28 | 5 | 57 |
5 | 13 | 793.32 | 20 | 14.79 | 1462 | 432 | 3.26 / 620.71 | 5 | 67 |
6 | 13 | 192.20 | 20 | 15.00 | 610 | 183 | 3.45 / 620.89 | 5 | 58 |
7 | 8 | 0.04 | 259 | 15.02 | 299 | 1163 | 4.61 / 622.06 | 6 | -99 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 20 | 15.04 | 448 | 135 | 0.13 / 613.04 | 6 | 8 |
2 | 3 | 1327.72 | -3 | 15.38 | 3 | 0 | 0.00 / 613.04 | 6 | 8 |
3 | 7 | 1356.08 | 40 | 14.76 | 2220 | 1311 | 1.45 / 614.35 | 8 | 52 |
4 | 13 | 1341.52 | 20 | 14.74 | 2203 | 649 | 2.09 / 615.00 | 5 | 57 |
5 | 13 | 1312.96 | 20 | 14.70 | 2166 | 637 | 2.73 / 615.64 | 5 | 59 |
6 | 13 | 830.92 | 20 | 14.79 | 1510 | 447 | 3.18 / 616.08 | 5 | 64 |
7 | 13 | 149.20 | 20 | 15.03 | 539 | 162 | 3.34 / 616.25 | 5 | 54 |
8 | 13 | 76.60 | 20 | 15.05 | 430 | 129 | 3.47 / 616.37 | 6 | 53 |
9 | 8 | 0.00 | 240 | 15.03 | 297 | 1071 | 4.54 / 617.45 | 6 | 175 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 23 | 15.04 | 430 | 149 | 0.15 / 608.38 | 6 | 8 |
2 | 3 | 1409.88 | -1 | 15.38 | 3 | 0 | 0.00 / 608.38 | 6 | 8 |
3 | 7 | 1491.12 | 40 | 14.71 | 2400 | 1412 | 1.56 / 609.79 | 8 | 51 |
4 | 13 | 1468.68 | 20 | 14.70 | 2375 | 698 | 2.26 / 610.49 | 5 | 54 |
5 | 13 | 1337.92 | 20 | 14.67 | 2202 | 646 | 2.91 / 611.14 | 5 | 57 |
6 | 13 | 686.16 | 20 | 14.84 | 1313 | 390 | 3.29 / 611.53 | 5 | 64 |
7 | 13 | 201.72 | 20 | 15.01 | 617 | 185 | 3.48 / 611.71 | 5 | 55 |
8 | 13 | 58.16 | 20 | 15.06 | 397 | 120 | 3.60 / 611.83 | 6 | 41 |
9 | 8 | 0.04 | 240 | 15.03 | 297 | 1071 | 4.67 / 612.91 | 6 | 139 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 23 | 15.04 | 429 | 148 | 0.15 / 603.02 | 6 | 7 |
2 | 7 | 1833.48 | 40 | 14.59 | 2857 | 1667 | 1.82 / 604.69 | 7 | 45 |
3 | 13 | 1807.92 | 20 | 14.57 | 2826 | 823 | 2.64 / 605.51 | 5 | 48 |
4 | 13 | 1709.76 | 20 | 14.53 | 2700 | 785 | 3.42 / 606.30 | 5 | 51 |
5 | 13 | 903.80 | 20 | 14.74 | 1615 | 476 | 3.90 / 606.77 | 5 | 67 |
6 | 13 | 280.44 | 20 | 14.97 | 740 | 222 | 4.12 / 606.99 | 5 | 62 |
7 | 13 | 96.08 | 20 | 15.03 | 455 | 137 | 4.26 / 607.13 | 6 | 56 |
8 | 8 | 0.04 | 246 | 15.01 | 299 | 1104 | 5.36 / 608.23 | 6 | -99 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 23 | 15.02 | 429 | 148 | 0.15 / 597.40 | 6 | 9 |
2 | 7 | 2004.64 | 40 | 14.53 | 3091 | 1796 | 1.94 / 599.20 | 9 | 41 |
3 | 13 | 1977.00 | 20 | 14.51 | 3069 | 891 | 2.84 / 600.09 | 5 | 47 |
4 | 13 | 1630.72 | 20 | 14.53 | 2603 | 756 | 3.59 / 600.84 | 5 | 54 |
5 | 13 | 932.44 | 20 | 14.72 | 1659 | 488 | 4.08 / 601.33 | 5 | 66 |
6 | 13 | 412.88 | 20 | 14.91 | 929 | 277 | 4.36 / 601.61 | 5 | 66 |
7 | 13 | 105.24 | 20 | 15.02 | 471 | 141 | 4.50 / 601.75 | 6 | 43 |
8 | 8 | 0.04 | 248 | 15.01 | 301 | 1120 | 5.62 / 602.87 | 6 | -99 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 23 | 15.01 | 438 | 151 | 0.15 / 591.73 | 6 | 9 |
2 | 7 | 2008.24 | 40 | 14.53 | 3086 | 1794 | 1.94 / 593.53 | 9 | 42 |
3 | 13 | 1981.00 | 20 | 14.51 | 3051 | 885 | 2.83 / 594.41 | 5 | 46 |
4 | 13 | 1731.64 | 20 | 14.51 | 2722 | 790 | 3.62 / 595.20 | 5 | 52 |
5 | 13 | 1010.68 | 20 | 14.69 | 1763 | 518 | 4.14 / 595.72 | 5 | 63 |
6 | 13 | 435.40 | 20 | 14.89 | 968 | 288 | 4.43 / 596.01 | 5 | 68 |
7 | 13 | 49.40 | 20 | 15.04 | 388 | 117 | 4.54 / 596.12 | 6 | 52 |
8 | 8 | 0.04 | 248 | 15.01 | 303 | 1128 | 5.67 / 597.25 | 6 | -99 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 23 | 15.03 | 429 | 148 | 0.15 / 585.93 | 6 | 7 |
2 | 7 | 2013.72 | 40 | 14.53 | 3099 | 1801 | 1.95 / 587.73 | 7 | 42 |
3 | 13 | 1989.68 | 20 | 14.50 | 3078 | 893 | 2.84 / 588.62 | 5 | 47 |
4 | 13 | 1819.64 | 20 | 14.48 | 2841 | 823 | 3.66 / 589.45 | 5 | 49 |
5 | 13 | 1064.40 | 20 | 14.67 | 1836 | 539 | 4.20 / 589.98 | 5 | 64 |
6 | 13 | 519.80 | 20 | 14.85 | 1078 | 320 | 4.52 / 590.31 | 5 | 69 |
7 | 13 | 75.76 | 20 | 15.02 | 444 | 133 | 4.66 / 590.44 | 6 | 58 |
8 | 8 | 0.00 | 246 | 14.99 | 310 | 1143 | 5.80 / 591.58 | 6 | 143 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 23 | 15.03 | 433 | 150 | 0.15 / 580.44 | 6 | 7 |
2 | 7 | 2010.84 | 40 | 14.53 | 3103 | 1803 | 1.95 / 582.24 | 7 | 41 |
3 | 13 | 1983.64 | 20 | 14.50 | 3078 | 893 | 2.85 / 583.13 | 5 | 46 |
4 | 13 | 1606.68 | 20 | 14.54 | 2555 | 743 | 3.59 / 583.87 | 5 | 51 |
5 | 13 | 942.24 | 20 | 14.71 | 1669 | 491 | 4.08 / 584.37 | 5 | 63 |
6 | 13 | 235.00 | 20 | 14.98 | 675 | 202 | 4.28 / 584.57 | 5 | 60 |
7 | 13 | 61.72 | 20 | 15.04 | 402 | 121 | 4.40 / 584.69 | 6 | 49 |
8 | 8 | 0.04 | 246 | 15.01 | 296 | 1093 | 5.50 / 585.78 | 6 | -99 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 23 | 15.04 | 445 | 154 | 0.15 / 574.68 | 6 | 9 |
2 | 7 | 2004.52 | 40 | 14.53 | 3090 | 1796 | 1.95 / 576.47 | 9 | 42 |
3 | 13 | 1977.72 | 20 | 14.50 | 3061 | 888 | 2.84 / 577.36 | 5 | 45 |
4 | 13 | 1700.76 | 20 | 14.51 | 2691 | 781 | 3.62 / 578.14 | 5 | 49 |
5 | 13 | 1129.80 | 20 | 14.64 | 1930 | 565 | 4.18 / 578.71 | 5 | 60 |
6 | 13 | 438.76 | 20 | 14.89 | 970 | 289 | 4.47 / 578.99 | 5 | 66 |
7 | 13 | 132.40 | 20 | 15.01 | 517 | 155 | 4.63 / 579.15 | 6 | 52 |
8 | 13 | 31.84 | 20 | 15.04 | 360 | 108 | 4.74 / 579.26 | 6 | 39 |
9 | 8 | 0.00 | 229 | 15.00 | 299 | 1027 | 5.76 / 580.29 | 6 | -99 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 23 | 15.01 | 450 | 155 | 0.16 / 569.04 | 6 | 9 |
2 | 7 | 2008.36 | 40 | 14.54 | 3099 | 1802 | 1.96 / 570.84 | 9 | 42 |
3 | 13 | 1978.60 | 20 | 14.52 | 3058 | 888 | 2.85 / 571.73 | 5 | 46 |
4 | 13 | 1409.00 | 20 | 14.61 | 2302 | 673 | 3.52 / 572.40 | 5 | 55 |
5 | 13 | 1032.56 | 20 | 14.69 | 1789 | 526 | 4.04 / 572.93 | 5 | 64 |
6 | 13 | 515.36 | 20 | 14.87 | 1071 | 319 | 4.36 / 573.25 | 5 | 61 |
7 | 13 | 179.28 | 20 | 15.00 | 581 | 174 | 4.54 / 573.42 | 5 | 55 |
8 | 8 | 0.04 | 246 | 15.02 | 298 | 1101 | 5.64 / 574.52 | 6 | 164 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 23 | 15.00 | 439 | 151 | 0.15 / 563.50 | 6 | 8 |
2 | 7 | 2010.20 | 40 | 14.54 | 3097 | 1801 | 1.95 / 565.30 | 8 | 42 |
3 | 13 | 1979.12 | 20 | 14.51 | 3071 | 891 | 2.84 / 566.19 | 5 | 44 |
4 | 13 | 1575.08 | 20 | 14.56 | 2516 | 733 | 3.58 / 566.92 | 5 | 53 |
5 | 13 | 981.72 | 20 | 14.70 | 1716 | 505 | 4.08 / 567.43 | 5 | 64 |
6 | 13 | 208.60 | 20 | 14.98 | 640 | 192 | 4.27 / 567.62 | 5 | 61 |
7 | 13 | 54.84 | 20 | 15.04 | 406 | 122 | 4.39 / 567.74 | 6 | 57 |
8 | 8 | 0.04 | 244 | 15.00 | 312 | 1142 | 5.54 / 568.88 | 6 | 147 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 23 | 15.03 | 440 | 152 | 0.15 / 557.88 | 6 | 7 |
2 | 7 | 2014.48 | 40 | 14.53 | 3102 | 1803 | 1.95 / 559.68 | 7 | 42 |
3 | 13 | 1986.00 | 20 | 14.50 | 3066 | 889 | 2.84 / 560.57 | 5 | 45 |
4 | 13 | 1638.36 | 20 | 14.53 | 2601 | 756 | 3.60 / 561.33 | 5 | 52 |
5 | 13 | 1000.40 | 20 | 14.69 | 1748 | 514 | 4.11 / 561.84 | 5 | 62 |
6 | 13 | 342.16 | 20 | 14.92 | 837 | 250 | 4.36 / 562.09 | 5 | 66 |
7 | 13 | 38.04 | 20 | 15.04 | 382 | 115 | 4.48 / 562.20 | 6 | 53 |
8 | 8 | 0.04 | 246 | 14.99 | 310 | 1143 | 5.62 / 563.35 | 6 | 190 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 23 | 15.04 | 440 | 152 | 0.15 / 552.27 | 6 | 7 |
2 | 7 | 2004.44 | 40 | 14.53 | 3090 | 1796 | 1.95 / 554.06 | 7 | 42 |
3 | 13 | 1975.08 | 20 | 14.50 | 3061 | 888 | 2.84 / 554.95 | 5 | 43 |
4 | 13 | 1694.64 | 20 | 14.52 | 2688 | 781 | 3.62 / 555.73 | 5 | 49 |
5 | 13 | 1023.68 | 20 | 14.69 | 1782 | 524 | 4.14 / 556.25 | 5 | 60 |
6 | 13 | 289.44 | 20 | 14.96 | 754 | 226 | 4.37 / 556.48 | 5 | 55 |
7 | 13 | 103.44 | 20 | 15.03 | 469 | 141 | 4.51 / 556.62 | 6 | 49 |
8 | 8 | 0.12 | 248 | 15.01 | 297 | 1106 | 5.61 / 557.73 | 6 | -99 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 23 | 15.04 | 428 | 148 | 0.15 / 546.65 | 6 | 7 |
2 | 7 | 2011.12 | 40 | 14.53 | 3099 | 1801 | 1.95 / 548.45 | 7 | 42 |
3 | 13 | 1981.52 | 20 | 14.51 | 3058 | 887 | 2.84 / 549.34 | 5 | 45 |
4 | 13 | 1558.52 | 20 | 14.55 | 2501 | 728 | 3.56 / 550.07 | 5 | 52 |
5 | 13 | 989.44 | 20 | 14.70 | 1726 | 507 | 4.07 / 550.58 | 5 | 62 |
6 | 13 | 403.36 | 20 | 14.92 | 911 | 272 | 4.34 / 550.85 | 5 | 58 |
7 | 13 | 128.64 | 20 | 15.02 | 500 | 150 | 4.49 / 551.00 | 6 | 46 |
8 | 13 | 34.80 | 20 | 15.05 | 356 | 107 | 4.60 / 551.11 | 6 | 38 |
9 | 8 | 0.16 | 227 | 15.01 | 296 | 1009 | 5.61 / 552.11 | 6 | 236 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 23 | 15.04 | 430 | 149 | 0.15 / 541.10 | 6 | 6 |
2 | 7 | 2009.96 | 40 | 14.53 | 3098 | 1801 | 1.95 / 542.91 | 6 | 41 |
3 | 13 | 1978.28 | 20 | 14.50 | 3058 | 887 | 2.84 / 543.79 | 5 | 46 |
4 | 13 | 1538.60 | 20 | 14.56 | 2476 | 721 | 3.56 / 544.51 | 5 | 51 |
5 | 13 | 955.88 | 20 | 14.72 | 1681 | 495 | 4.05 / 545.01 | 5 | 60 |
6 | 13 | 397.20 | 20 | 14.92 | 894 | 267 | 4.32 / 545.27 | 5 | 58 |
7 | 13 | 123.08 | 20 | 15.02 | 490 | 147 | 4.47 / 545.42 | 6 | 42 |
8 | 8 | -0.04 | 246 | 15.02 | 293 | 1083 | 5.55 / 546.50 | 6 | 139 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 23 | 15.04 | 435 | 150 | 0.15 / 535.54 | 6 | 6 |
2 | 7 | 2004.36 | 41 | 14.53 | 3090 | 1841 | 1.99 / 537.38 | 6 | 42 |
3 | 13 | 1972.80 | 20 | 14.51 | 3057 | 887 | 2.88 / 538.27 | 5 | 45 |
4 | 13 | 1609.32 | 20 | 14.54 | 2569 | 747 | 3.63 / 539.01 | 5 | 51 |
5 | 13 | 957.16 | 20 | 14.72 | 1686 | 496 | 4.12 / 539.51 | 5 | 61 |
6 | 13 | 304.96 | 20 | 14.97 | 764 | 229 | 4.35 / 539.74 | 5 | 53 |
7 | 13 | 123.52 | 20 | 15.03 | 487 | 146 | 4.50 / 539.88 | 6 | 46 |
8 | 8 | 0.04 | 246 | 15.02 | 290 | 1072 | 5.57 / 540.96 | 6 | 228 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 23 | 15.04 | 432 | 149 | 0.15 / 529.88 | 6 | 8 |
2 | 7 | 2010.40 | 40 | 14.54 | 3095 | 1800 | 1.95 / 531.68 | 8 | 41 |
3 | 13 | 1981.36 | 20 | 14.51 | 3065 | 889 | 2.84 / 532.57 | 5 | 42 |
4 | 13 | 1626.56 | 20 | 14.54 | 2595 | 755 | 3.59 / 533.32 | 5 | 52 |
5 | 13 | 1174.28 | 20 | 14.64 | 1991 | 583 | 4.18 / 533.91 | 5 | 62 |
6 | 13 | 343.16 | 20 | 14.95 | 819 | 245 | 4.42 / 534.15 | 5 | 54 |
7 | 13 | 126.40 | 20 | 15.03 | 492 | 148 | 4.57 / 534.30 | 6 | 47 |
8 | 8 | 0.08 | 248 | 15.03 | 292 | 1088 | 5.66 / 535.39 | 6 | -99 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 23 | 15.04 | 425 | 147 | 0.15 / 524.42 | 6 | 6 |
2 | 7 | 2013.40 | 40 | 14.53 | 3101 | 1802 | 1.95 / 526.22 | 6 | 42 |
3 | 13 | 1984.28 | 20 | 14.51 | 3064 | 889 | 2.84 / 527.11 | 5 | 45 |
4 | 13 | 1463.24 | 20 | 14.58 | 2360 | 688 | 3.53 / 527.80 | 5 | 54 |
5 | 13 | 985.24 | 20 | 14.70 | 1722 | 506 | 4.03 / 528.30 | 5 | 62 |
6 | 13 | 251.52 | 20 | 14.99 | 688 | 206 | 4.24 / 528.51 | 5 | 53 |
7 | 13 | 105.36 | 20 | 15.03 | 467 | 140 | 4.38 / 528.65 | 6 | 44 |
8 | 8 | 0.16 | 246 | 15.02 | 292 | 1079 | 5.46 / 529.73 | 6 | -99 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 23 | 15.03 | 434 | 150 | 0.15 / 518.92 | 6 | 7 |
2 | 7 | 2005.68 | 40 | 14.54 | 3083 | 1793 | 1.94 / 520.72 | 7 | 42 |
3 | 13 | 1976.44 | 20 | 14.52 | 3056 | 887 | 2.83 / 521.61 | 5 | 46 |
4 | 13 | 1484.72 | 20 | 14.58 | 2408 | 702 | 3.53 / 522.31 | 5 | 53 |
5 | 13 | 963.04 | 20 | 14.71 | 1698 | 500 | 4.03 / 522.81 | 5 | 65 |
6 | 13 | 300.80 | 20 | 14.96 | 757 | 226 | 4.26 / 523.03 | 5 | 55 |
7 | 13 | 108.48 | 20 | 15.03 | 474 | 142 | 4.40 / 523.18 | 6 | 45 |
8 | 8 | 0.08 | 248 | 15.02 | 294 | 1095 | 5.50 / 524.27 | 6 | -99 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 23 | 15.05 | 429 | 148 | 0.15 / 513.36 | 6 | 7 |
2 | 7 | 2012.36 | 40 | 14.53 | 3093 | 1798 | 1.95 / 515.16 | 7 | 42 |
3 | 13 | 1983.72 | 20 | 14.51 | 3067 | 890 | 2.84 / 516.05 | 5 | 45 |
4 | 13 | 1636.84 | 20 | 14.53 | 2604 | 757 | 3.59 / 516.81 | 5 | 52 |
5 | 13 | 934.92 | 20 | 14.72 | 1659 | 488 | 4.08 / 517.30 | 5 | 63 |
6 | 13 | 349.20 | 20 | 14.95 | 830 | 248 | 4.33 / 517.54 | 5 | 57 |
7 | 13 | 123.88 | 20 | 15.03 | 490 | 147 | 4.48 / 517.69 | 6 | 45 |
8 | 8 | 0.00 | 248 | 15.02 | 291 | 1084 | 5.56 / 518.77 | 6 | 227 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 23 | 15.05 | 433 | 150 | 0.15 / 507.86 | 6 | 6 |
2 | 7 | 2008.44 | 40 | 14.53 | 3096 | 1799 | 1.95 / 509.66 | 6 | 42 |
3 | 13 | 1978.92 | 20 | 14.51 | 3063 | 889 | 2.84 / 510.55 | 5 | 46 |
4 | 13 | 1555.44 | 20 | 14.55 | 2497 | 727 | 3.56 / 511.27 | 5 | 52 |
5 | 13 | 899.48 | 20 | 14.74 | 1611 | 475 | 4.04 / 511.75 | 5 | 65 |
6 | 13 | 323.88 | 20 | 14.96 | 791 | 237 | 4.28 / 511.99 | 5 | 52 |
7 | 13 | 134.92 | 20 | 15.03 | 501 | 151 | 4.43 / 512.14 | 6 | 42 |
8 | 8 | 0.04 | 248 | 15.03 | 289 | 1077 | 5.50 / 513.21 | 6 | -99 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 23 | 15.05 | 423 | 146 | 0.15 / 502.29 | 6 | 7 |
2 | 7 | 2012.72 | 40 | 14.53 | 3103 | 1803 | 1.95 / 504.10 | 7 | 44 |
3 | 13 | 1981.20 | 20 | 14.51 | 3059 | 888 | 2.84 / 504.98 | 5 | 46 |
4 | 13 | 1550.76 | 20 | 14.56 | 2498 | 727 | 3.57 / 505.71 | 5 | 53 |
5 | 13 | 1022.76 | 20 | 14.69 | 1782 | 524 | 4.09 / 506.23 | 5 | 63 |
6 | 13 | 308.92 | 20 | 14.97 | 774 | 232 | 4.32 / 506.47 | 5 | 52 |
7 | 13 | 123.40 | 20 | 15.03 | 493 | 148 | 4.47 / 506.61 | 6 | 43 |
8 | 13 | 26.48 | 20 | 15.06 | 343 | 103 | 4.57 / 506.72 | 6 | 38 |
9 | 8 | 0.04 | 227 | 15.02 | 291 | 992 | 5.56 / 507.71 | 6 | -99 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 23 | 15.05 | 430 | 149 | 0.15 / 496.66 | 6 | 6 |
2 | 7 | 2013.92 | 40 | 14.54 | 3095 | 1800 | 1.95 / 498.46 | 6 | 42 |
3 | 13 | 1983.60 | 20 | 14.52 | 3065 | 890 | 2.84 / 499.35 | 5 | 46 |
4 | 13 | 1660.88 | 20 | 14.53 | 2637 | 766 | 3.61 / 500.12 | 5 | 52 |
5 | 13 | 1024.80 | 20 | 14.69 | 1782 | 524 | 4.13 / 500.64 | 5 | 62 |
6 | 13 | 391.88 | 20 | 14.93 | 890 | 266 | 4.39 / 500.91 | 5 | 58 |
7 | 13 | 157.32 | 20 | 15.02 | 543 | 163 | 4.56 / 501.07 | 6 | 46 |
8 | 8 | 0.20 | 248 | 15.03 | 288 | 1074 | 5.63 / 502.15 | 6 | -99 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 23 | 15.05 | 423 | 146 | 0.15 / 491.14 | 6 | 7 |
2 | 7 | 2004.60 | 41 | 14.54 | 3087 | 1840 | 1.99 / 492.98 | 7 | 42 |
3 | 13 | 1974.60 | 20 | 14.51 | 3056 | 887 | 2.87 / 493.87 | 5 | 44 |
4 | 13 | 1544.84 | 20 | 14.57 | 2480 | 723 | 3.60 / 494.59 | 5 | 54 |
5 | 13 | 919.60 | 20 | 14.74 | 1632 | 481 | 4.08 / 495.07 | 5 | 61 |
6 | 13 | 299.12 | 20 | 14.98 | 752 | 225 | 4.30 / 495.30 | 5 | 51 |
7 | 13 | 153.96 | 20 | 15.02 | 534 | 160 | 4.46 / 495.46 | 6 | 43 |
8 | 8 | 0.04 | 246 | 15.03 | 286 | 1057 | 5.52 / 496.51 | 6 | 179 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 23 | 15.05 | 434 | 150 | 0.15 / 485.55 | 6 | 7 |
2 | 7 | 2012.64 | 40 | 14.54 | 3100 | 1803 | 1.95 / 487.35 | 7 | 41 |
3 | 13 | 1986.28 | 20 | 14.52 | 3069 | 891 | 2.84 / 488.24 | 5 | 46 |
4 | 13 | 1505.96 | 20 | 14.58 | 2435 | 710 | 3.55 / 488.95 | 5 | 53 |
5 | 13 | 1119.76 | 20 | 14.66 | 1906 | 559 | 4.11 / 489.51 | 5 | 60 |
6 | 13 | 365.68 | 20 | 14.95 | 852 | 255 | 4.37 / 489.76 | 5 | 55 |
7 | 13 | 142.32 | 20 | 15.03 | 519 | 156 | 4.52 / 489.92 | 6 | 44 |
8 | 8 | 0.24 | 248 | 15.03 | 288 | 1074 | 5.60 / 490.99 | 6 | 236 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 22 | 15.04 | 443 | 147 | 0.15 / 480.01 | 6 | 6 |
2 | 7 | 2004.44 | 40 | 14.54 | 3082 | 1792 | 1.94 / 481.80 | 6 | 41 |
3 | 13 | 1973.28 | 20 | 14.52 | 3054 | 887 | 2.83 / 482.69 | 5 | 46 |
4 | 13 | 1496.36 | 20 | 14.58 | 2420 | 706 | 3.53 / 483.39 | 5 | 54 |
5 | 13 | 1021.20 | 20 | 14.70 | 1773 | 521 | 4.05 / 483.91 | 5 | 62 |
6 | 13 | 381.84 | 20 | 14.94 | 884 | 264 | 4.32 / 484.18 | 5 | 58 |
7 | 13 | 108.64 | 20 | 15.04 | 471 | 142 | 4.46 / 484.32 | 6 | 43 |
8 | 8 | 0.12 | 246 | 15.03 | 291 | 1076 | 5.53 / 485.40 | 6 | 154 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 22 | 15.04 | 436 | 144 | 0.14 / 474.34 | 6 | 6 |
2 | 7 | 2009.76 | 40 | 14.55 | 3087 | 1797 | 1.94 / 476.14 | 6 | 41 |
3 | 13 | 1981.40 | 20 | 14.52 | 3076 | 893 | 2.83 / 477.03 | 5 | 44 |
4 | 13 | 1670.76 | 20 | 14.54 | 2657 | 773 | 3.61 / 477.81 | 5 | 52 |
5 | 13 | 962.48 | 20 | 14.72 | 1698 | 500 | 4.11 / 478.31 | 5 | 64 |
6 | 13 | 510.44 | 20 | 14.88 | 1064 | 317 | 4.42 / 478.62 | 5 | 65 |
7 | 13 | 109.52 | 20 | 15.03 | 476 | 143 | 4.57 / 478.77 | 6 | 44 |
8 | 8 | 0.04 | 248 | 15.02 | 294 | 1095 | 5.66 / 479.86 | 6 | -99 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 22 | 15.05 | 435 | 144 | 0.14 / 468.65 | 6 | 7 |
2 | 7 | 2008.72 | 40 | 14.54 | 3098 | 1802 | 1.95 / 470.45 | 7 | 41 |
3 | 13 | 1977.84 | 20 | 14.53 | 3062 | 890 | 2.84 / 471.34 | 5 | 46 |
4 | 13 | 1627.92 | 20 | 14.55 | 2587 | 753 | 3.59 / 472.09 | 5 | 52 |
5 | 13 | 1174.40 | 20 | 14.65 | 1982 | 581 | 4.17 / 472.68 | 5 | 61 |
6 | 13 | 441.36 | 20 | 14.90 | 974 | 290 | 4.46 / 472.97 | 5 | 63 |
7 | 13 | 91.96 | 20 | 15.04 | 449 | 135 | 4.59 / 473.10 | 6 | 47 |
8 | 8 | 0.00 | 248 | 15.03 | 295 | 1100 | 5.69 / 474.20 | 6 | -99 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 22 | 15.06 | 435 | 144 | 0.14 / 463.13 | 6 | 6 |
2 | 7 | 2009.24 | 40 | 14.54 | 3096 | 1801 | 1.94 / 464.93 | 6 | 43 |
3 | 13 | 1981.04 | 20 | 14.52 | 3071 | 892 | 2.84 / 465.82 | 5 | 43 |
4 | 13 | 1598.80 | 20 | 14.56 | 2554 | 744 | 3.58 / 466.56 | 5 | 54 |
5 | 13 | 962.16 | 20 | 14.72 | 1696 | 499 | 4.08 / 467.06 | 5 | 63 |
6 | 13 | 261.24 | 20 | 14.99 | 700 | 210 | 4.29 / 467.27 | 5 | 51 |
7 | 13 | 111.68 | 20 | 15.04 | 478 | 144 | 4.43 / 467.42 | 6 | 44 |
8 | 8 | 0.08 | 246 | 15.03 | 295 | 1091 | 5.52 / 468.51 | 6 | 179 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 22 | 15.04 | 436 | 144 | 0.14 / 457.52 | 6 | 6 |
2 | 7 | 2003.92 | 40 | 14.56 | 3097 | 1804 | 1.95 / 459.32 | 6 | 41 |
3 | 13 | 1976.00 | 20 | 14.54 | 3057 | 889 | 2.84 / 460.21 | 5 | 44 |
4 | 13 | 1632.88 | 20 | 14.56 | 2605 | 759 | 3.60 / 460.97 | 5 | 52 |
5 | 13 | 965.52 | 20 | 14.74 | 1702 | 502 | 4.10 / 461.47 | 5 | 62 |
6 | 13 | 408.52 | 20 | 14.93 | 920 | 275 | 4.37 / 461.75 | 5 | 60 |
7 | 13 | 136.08 | 20 | 15.04 | 517 | 156 | 4.53 / 461.90 | 6 | 49 |
8 | 8 | 0.12 | 246 | 15.04 | 292 | 1080 | 5.61 / 462.98 | 6 | 171 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 22 | 15.03 | 453 | 150 | 0.15 / 451.50 | 6 | 6 |
2 | 7 | 2016.36 | 40 | 14.56 | 3109 | 1811 | 1.96 / 453.31 | 6 | 42 |
3 | 13 | 1989.04 | 20 | 14.54 | 3071 | 893 | 2.85 / 454.20 | 5 | 45 |
4 | 13 | 1743.84 | 20 | 14.54 | 2747 | 799 | 3.65 / 455.00 | 5 | 50 |
5 | 13 | 1453.32 | 20 | 14.57 | 2365 | 689 | 4.34 / 455.69 | 5 | 55 |
6 | 13 | 704.12 | 20 | 14.80 | 1347 | 399 | 4.74 / 456.09 | 5 | 67 |
7 | 13 | 87.60 | 20 | 15.04 | 457 | 137 | 4.88 / 456.23 | 6 | 53 |
8 | 8 | 0.12 | 250 | 15.02 | 306 | 1149 | 6.03 / 457.37 | 6 | 223 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 22 | 15.03 | 439 | 145 | 0.15 / 445.83 | 6 | 7 |
2 | 7 | 2005.08 | 41 | 14.56 | 3081 | 1839 | 1.98 / 447.67 | 7 | 43 |
3 | 13 | 1975.20 | 20 | 14.55 | 3049 | 887 | 2.87 / 448.55 | 5 | 44 |
4 | 13 | 1624.96 | 20 | 14.57 | 2586 | 754 | 3.63 / 449.31 | 5 | 51 |
5 | 13 | 947.12 | 20 | 14.73 | 1676 | 494 | 4.12 / 449.80 | 5 | 64 |
6 | 13 | 349.68 | 20 | 14.94 | 849 | 254 | 4.37 / 450.06 | 5 | 68 |
7 | 13 | 39.28 | 20 | 15.05 | 393 | 118 | 4.49 / 450.17 | 5 | 59 |
8 | 13 | 11.72 | 20 | 15.05 | 346 | 104 | 4.60 / 450.28 | 6 | 58 |
9 | 8 | -0.04 | 225 | 15.00 | 317 | 1070 | 5.66 / 451.35 | 6 | 150 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 22 | 15.03 | 445 | 147 | 0.15 / 440.23 | 6 | 6 |
2 | 7 | 2010.36 | 40 | 14.56 | 3096 | 1803 | 1.95 / 442.03 | 6 | 42 |
3 | 13 | 1982.28 | 20 | 14.55 | 3057 | 890 | 2.84 / 442.92 | 5 | 44 |
4 | 13 | 1462.64 | 20 | 14.61 | 2371 | 693 | 3.53 / 443.61 | 5 | 54 |
5 | 13 | 1018.64 | 20 | 14.71 | 1774 | 522 | 4.05 / 444.14 | 5 | 64 |
6 | 13 | 326.76 | 20 | 14.95 | 822 | 246 | 4.30 / 444.38 | 5 | 66 |
7 | 13 | 54.48 | 20 | 15.05 | 415 | 125 | 4.43 / 444.51 | 5 | 57 |
8 | 13 | 15.44 | 20 | 15.05 | 349 | 105 | 4.53 / 444.61 | 6 | 55 |
9 | 8 | 0.08 | 225 | 15.01 | 317 | 1071 | 5.60 / 445.68 | 6 | 173 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 22 | 15.04 | 450 | 149 | 0.15 / 434.57 | 6 | 7 |
2 | 7 | 2012.72 | 40 | 14.57 | 3099 | 1806 | 1.95 / 436.37 | 7 | 41 |
3 | 13 | 1984.12 | 20 | 14.55 | 3069 | 893 | 2.85 / 437.27 | 5 | 44 |
4 | 13 | 1706.84 | 20 | 14.55 | 2701 | 786 | 3.63 / 438.05 | 5 | 52 |
5 | 13 | 883.24 | 20 | 14.76 | 1596 | 471 | 4.11 / 438.53 | 5 | 67 |
6 | 13 | 367.36 | 20 | 14.93 | 875 | 261 | 4.37 / 438.79 | 5 | 68 |
7 | 13 | 44.12 | 20 | 15.06 | 398 | 120 | 4.49 / 438.91 | 5 | 60 |
8 | 13 | 13.28 | 20 | 15.06 | 349 | 105 | 4.59 / 439.01 | 6 | 57 |
9 | 8 | 0.00 | 225 | 15.01 | 317 | 1071 | 5.66 / 440.08 | 6 | 142 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 22 | 15.07 | 430 | 143 | 0.14 / 429.02 | 6 | 6 |
2 | 7 | 2010.76 | 40 | 14.56 | 3102 | 1807 | 1.95 / 430.83 | 6 | 42 |
3 | 13 | 1979.24 | 20 | 14.55 | 3054 | 889 | 2.84 / 431.71 | 5 | 44 |
4 | 13 | 1650.44 | 20 | 14.56 | 2628 | 765 | 3.60 / 432.48 | 5 | 50 |
5 | 13 | 874.36 | 20 | 14.77 | 1580 | 467 | 4.07 / 432.95 | 5 | 64 |
6 | 13 | 185.36 | 20 | 15.01 | 617 | 185 | 4.26 / 433.13 | 5 | 65 |
7 | 13 | 39.00 | 20 | 15.06 | 396 | 119 | 4.37 / 433.25 | 5 | 59 |
8 | 8 | 0.08 | 244 | 15.02 | 319 | 1169 | 5.54 / 434.42 | 6 | 136 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 22 | 15.06 | 433 | 143 | 0.14 / 423.56 | 6 | 7 |
2 | 7 | 2004.08 | 40 | 14.58 | 3078 | 1795 | 1.94 / 425.36 | 7 | 43 |
3 | 13 | 1974.32 | 20 | 14.56 | 3057 | 890 | 2.83 / 426.25 | 5 | 47 |
4 | 13 | 1504.84 | 20 | 14.63 | 2422 | 709 | 3.54 / 426.96 | 5 | 55 |
5 | 13 | 873.40 | 20 | 14.80 | 1573 | 466 | 4.00 / 427.42 | 5 | 64 |
6 | 13 | 214.96 | 20 | 15.03 | 652 | 196 | 4.20 / 427.62 | 5 | 60 |
7 | 13 | 69.88 | 20 | 15.08 | 429 | 129 | 4.33 / 427.75 | 6 | 51 |
8 | 8 | -0.04 | 246 | 15.05 | 305 | 1129 | 5.46 / 428.88 | 6 | -99 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 22 | 15.06 | 428 | 142 | 0.14 / 417.97 | 6 | 6 |
2 | 7 | 2015.76 | 40 | 14.57 | 3100 | 1807 | 1.95 / 419.78 | 6 | 41 |
3 | 13 | 1987.52 | 20 | 14.56 | 3074 | 895 | 2.84 / 420.67 | 5 | 46 |
4 | 13 | 1532.52 | 20 | 14.63 | 2466 | 722 | 3.57 / 421.39 | 5 | 54 |
5 | 13 | 1045.40 | 20 | 14.74 | 1795 | 529 | 4.09 / 421.92 | 5 | 62 |
6 | 13 | 265.32 | 20 | 15.01 | 726 | 218 | 4.31 / 422.14 | 5 | 62 |
7 | 13 | 77.80 | 20 | 15.07 | 441 | 133 | 4.45 / 422.27 | 6 | 51 |
8 | 13 | 24.24 | 20 | 15.08 | 355 | 107 | 4.55 / 422.38 | 6 | 46 |
9 | 8 | 0.04 | 227 | 15.04 | 304 | 1038 | 5.59 / 423.42 | 6 | 153 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 22 | 15.05 | 428 | 142 | 0.14 / 412.37 | 6 | 7 |
2 | 7 | 2013.76 | 40 | 14.57 | 3109 | 1812 | 1.95 / 414.19 | 7 | 40 |
3 | 13 | 1983.36 | 20 | 14.56 | 3072 | 895 | 2.85 / 415.08 | 5 | 45 |
4 | 13 | 1562.00 | 20 | 14.61 | 2510 | 733 | 3.58 / 415.81 | 5 | 52 |
5 | 13 | 1040.48 | 20 | 14.73 | 1806 | 532 | 4.11 / 416.35 | 5 | 62 |
6 | 13 | 262.00 | 20 | 15.00 | 723 | 217 | 4.33 / 416.56 | 5 | 60 |
7 | 13 | 74.64 | 20 | 15.07 | 435 | 131 | 4.46 / 416.69 | 6 | 51 |
8 | 8 | 0.12 | 248 | 15.04 | 304 | 1134 | 5.60 / 417.83 | 6 | -99 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 22 | 14.99 | 436 | 144 | 0.14 / 406.81 | 6 | 6 |
2 | 3 | 1520.20 | 1 | 14.96 | 2477 | 37 | 0.18 / 406.85 | 5 | 35 |
3 | 7 | 2014.28 | 41 | 14.57 | 3101 | 1852 | 2.03 / 408.70 | 35 | 40 |
4 | 13 | 1984.68 | 20 | 14.55 | 3070 | 893 | 2.93 / 409.60 | 5 | 45 |
5 | 13 | 1526.32 | 20 | 14.62 | 2446 | 715 | 3.64 / 410.31 | 5 | 54 |
6 | 13 | 910.80 | 20 | 14.77 | 1620 | 479 | 4.12 / 410.79 | 5 | 63 |
7 | 13 | 220.04 | 20 | 15.01 | 652 | 196 | 4.32 / 410.99 | 5 | 55 |
8 | 13 | 77.76 | 20 | 15.06 | 436 | 131 | 4.45 / 411.12 | 6 | 47 |
9 | 8 | 0.12 | 246 | 15.03 | 302 | 1117 | 5.56 / 412.23 | 6 | 205 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 21 | 15.22 | 420 | 134 | 0.13 / 401.27 | 6 | 7 |
2 | 3 | 1540.40 | 1 | 14.89 | 2492 | 37 | 0.17 / 401.31 | 5 | 44 |
3 | 7 | 2010.24 | 40 | 14.53 | 3086 | 1794 | 1.96 / 403.10 | 44 | 42 |
4 | 13 | 1980.64 | 20 | 14.50 | 3049 | 884 | 2.85 / 403.99 | 5 | 44 |
5 | 13 | 1599.32 | 20 | 14.55 | 2561 | 745 | 3.59 / 404.73 | 5 | 53 |
6 | 13 | 899.20 | 20 | 14.72 | 1602 | 472 | 4.07 / 405.20 | 5 | 62 |
7 | 13 | 304.80 | 20 | 14.93 | 773 | 231 | 4.30 / 405.43 | 5 | 56 |
8 | 13 | 75.44 | 20 | 15.01 | 428 | 128 | 4.43 / 405.56 | 6 | 49 |
9 | 8 | 0.08 | 248 | 14.98 | 298 | 1107 | 5.53 / 406.67 | 6 | 190 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 65 | 15.04 | 428 | 418 | 0.42 / 399.59 | 6 | 7 |
2 | 3 | 132.08 | -6 | 15.42 | 3 | 0 | 0.00 / 399.59 | 6 | 7 |
3 | 7 | 241.60 | 40 | 15.36 | 618 | 380 | 0.80 / 399.97 | 7 | 17 |
4 | 13 | 132.24 | 20 | 15.35 | 468 | 144 | 0.94 / 400.11 | 6 | 26 |
5 | 8 | 0.04 | 248 | 15.30 | 270 | 1024 | 1.97 / 401.14 | 6 | 145 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 75 | 15.04 | 428 | 483 | 0.48 / 393.23 | 6 | 9 |
2 | 3 | 99.84 | -6 | 15.40 | 3 | 0 | 0.00 / 393.23 | 6 | 9 |
3 | 5 | 1027.00 | 13 | 15.05 | 1758 | 344 | 0.83 / 393.57 | 5 | 26 |
4 | 5 | 977.60 | 12 | 15.00 | 1693 | 305 | 1.13 / 393.88 | 5 | 39 |
5 | 7 | 2008.36 | 40 | 14.55 | 3087 | 1797 | 2.93 / 395.67 | 39 | 37 |
6 | 13 | 1980.04 | 20 | 14.53 | 3051 | 887 | 3.81 / 396.56 | 5 | 41 |
7 | 13 | 1496.36 | 20 | 14.61 | 2412 | 705 | 4.52 / 397.26 | 5 | 52 |
8 | 13 | 881.24 | 20 | 14.78 | 1582 | 468 | 4.99 / 397.73 | 5 | 62 |
9 | 13 | 220.92 | 20 | 15.02 | 652 | 196 | 5.18 / 397.93 | 5 | 53 |
10 | 13 | 74.48 | 20 | 15.07 | 428 | 129 | 5.31 / 398.06 | 6 | 49 |
11 | 8 | 0.04 | 246 | 15.05 | 301 | 1114 | 6.43 / 399.17 | 6 | 167 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 75 | 15.19 | 422 | 481 | 0.48 / 389.82 | 6 | 7 |
2 | 3 | 109.24 | -6 | 15.33 | 3 | 0 | 0.00 / 389.82 | 6 | 7 |
3 | 7 | 859.48 | 40 | 15.03 | 1476 | 887 | 1.37 / 390.71 | 7 | 18 |
4 | 13 | 835.12 | 20 | 15.00 | 1446 | 434 | 1.80 / 391.14 | 6 | 27 |
5 | 13 | 528.80 | 20 | 15.01 | 1051 | 316 | 2.12 / 391.46 | 6 | 34 |
6 | 13 | 145.64 | 20 | 15.10 | 522 | 158 | 2.28 / 391.62 | 6 | 43 |
7 | 13 | 40.84 | 20 | 15.13 | 362 | 110 | 2.38 / 391.73 | 6 | 41 |
8 | 8 | -0.04 | 233 | 15.08 | 290 | 1019 | 3.40 / 392.74 | 6 | -99 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 75 | 15.25 | 405 | 463 | 0.46 / 388.14 | 6 | 7 |
2 | 7 | 108.92 | 40 | 15.35 | 400 | 246 | 0.71 / 388.38 | 7 | 10 |
3 | 8 | 0.08 | 248 | 15.30 | 252 | 956 | 1.67 / 389.34 | 6 | 240 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 75 | 15.04 | 422 | 476 | 0.48 / 386.48 | 6 | 10 |
2 | 7 | 116.76 | 40 | 15.40 | 413 | 254 | 0.73 / 386.73 | 10 | 14 |
3 | 8 | 0.12 | 248 | 15.36 | 247 | 941 | 1.67 / 387.68 | 6 | -99 |
Average= | 5.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 75 | 15.25 | 411 | 470 | 0.47 / 380.72 | 6 | 8 |
2 | 7 | 1956.88 | 41 | 14.56 | 3018 | 1802 | 2.27 / 382.53 | 8 | 36 |
3 | 13 | 1927.60 | 20 | 14.53 | 2985 | 867 | 3.14 / 383.39 | 5 | 36 |
4 | 13 | 1403.36 | 20 | 14.62 | 2287 | 669 | 3.81 / 384.06 | 5 | 50 |
5 | 13 | 963.32 | 20 | 14.73 | 1679 | 495 | 4.30 / 384.56 | 5 | 57 |
6 | 13 | 295.84 | 20 | 14.99 | 769 | 231 | 4.53 / 384.79 | 5 | 57 |
7 | 13 | 108.40 | 20 | 15.06 | 479 | 144 | 4.68 / 384.93 | 6 | 46 |
8 | 8 | 0.08 | 244 | 15.05 | 292 | 1072 | 5.75 / 386.00 | 6 | 137 |
Average= | 5.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 75 | 15.07 | 426 | 481 | 0.48 / 379.05 | 6 | 8 |
2 | 7 | 111.76 | 41 | 15.41 | 408 | 258 | 0.74 / 379.31 | 8 | 10 |
3 | 8 | 0.28 | 246 | 15.37 | 251 | 949 | 1.69 / 380.25 | 6 | -99 |
Average= | 5.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 16 | 15.10 | 447 | 108 | 0.11 / 372.93 | 6 | 6 |
2 | 10 | 1502.96 | 4 | 14.85 | 2421 | 144 | 0.25 / 373.07 | 5 | 35 |
3 | 10 | 1509.72 | 3 | 14.84 | 2459 | 109 | 0.36 / 373.18 | 5 | 33 |
4 | 7 | 2010.12 | 40 | 14.57 | 3099 | 1806 | 2.17 / 374.99 | 33 | 42 |
5 | 13 | 1980.20 | 20 | 14.55 | 3071 | 894 | 3.06 / 375.88 | 5 | 45 |
6 | 13 | 1554.20 | 20 | 14.61 | 2500 | 730 | 3.79 / 376.61 | 5 | 54 |
7 | 13 | 967.32 | 20 | 14.77 | 1706 | 504 | 4.30 / 377.11 | 5 | 64 |
8 | 13 | 293.36 | 20 | 15.03 | 754 | 227 | 4.52 / 377.34 | 5 | 51 |
9 | 13 | 115.12 | 20 | 15.09 | 483 | 146 | 4.67 / 377.49 | 6 | 44 |
10 | 8 | 0.08 | 246 | 15.08 | 291 | 1080 | 5.75 / 378.57 | 6 | -99 |
Average= | 5.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 16 | 15.10 | 448 | 108 | 0.11 / 367.10 | 6 | 6 |
2 | 10 | 1505.08 | 4 | 14.86 | 2432 | 145 | 0.25 / 367.25 | 5 | 33 |
3 | 10 | 1511.24 | 3 | 14.85 | 2441 | 109 | 0.36 / 367.35 | 5 | 35 |
4 | 7 | 2004.84 | 40 | 14.57 | 3093 | 1803 | 2.16 / 369.16 | 35 | 42 |
5 | 13 | 1975.20 | 20 | 14.56 | 3058 | 890 | 3.05 / 370.05 | 5 | 45 |
6 | 13 | 1627.64 | 20 | 14.59 | 2592 | 756 | 3.81 / 370.80 | 5 | 51 |
7 | 13 | 966.12 | 20 | 14.77 | 1703 | 503 | 4.31 / 371.31 | 5 | 62 |
8 | 13 | 377.00 | 20 | 14.99 | 874 | 262 | 4.58 / 371.57 | 5 | 55 |
9 | 13 | 142.88 | 20 | 15.08 | 527 | 159 | 4.74 / 371.73 | 6 | 45 |
10 | 8 | 0.16 | 246 | 15.08 | 294 | 1091 | 5.83 / 372.82 | 6 | -99 |
Average= | 5.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 16 | 15.11 | 444 | 107 | 0.11 / 361.31 | 6 | 7 |
2 | 10 | 1506.80 | 3 | 14.86 | 2429 | 108 | 0.22 / 361.42 | 5 | 36 |
3 | 10 | 1527.52 | 3 | 14.85 | 2482 | 111 | 0.33 / 361.53 | 5 | 36 |
4 | 7 | 2012.88 | 40 | 14.57 | 3110 | 1813 | 2.14 / 363.34 | 36 | 43 |
5 | 13 | 1983.72 | 20 | 14.56 | 3071 | 894 | 3.03 / 364.24 | 5 | 46 |
6 | 13 | 1592.40 | 20 | 14.60 | 2551 | 745 | 3.78 / 364.98 | 5 | 53 |
7 | 13 | 1008.04 | 20 | 14.75 | 1762 | 520 | 4.30 / 365.50 | 5 | 62 |
8 | 13 | 292.72 | 20 | 15.02 | 759 | 228 | 4.53 / 365.73 | 5 | 55 |
9 | 13 | 147.92 | 20 | 15.07 | 538 | 162 | 4.69 / 365.89 | 6 | 46 |
10 | 8 | 0.04 | 246 | 15.08 | 297 | 1102 | 5.79 / 366.99 | 6 | -99 |
Average= | 5.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 16 | 15.11 | 439 | 106 | 0.11 / 355.52 | 6 | 6 |
2 | 10 | 1504.80 | 4 | 14.85 | 2430 | 144 | 0.25 / 355.66 | 5 | 34 |
3 | 10 | 1511.08 | 3 | 14.86 | 2437 | 109 | 0.36 / 355.77 | 5 | 38 |
4 | 7 | 2004.76 | 40 | 14.57 | 3096 | 1804 | 2.16 / 357.58 | 38 | 41 |
5 | 13 | 1973.88 | 20 | 14.56 | 3065 | 893 | 3.06 / 358.47 | 5 | 46 |
6 | 13 | 1613.36 | 20 | 14.60 | 2580 | 753 | 3.81 / 359.22 | 5 | 52 |
7 | 13 | 980.16 | 20 | 14.77 | 1726 | 510 | 4.32 / 359.73 | 5 | 64 |
8 | 13 | 275.28 | 20 | 15.04 | 734 | 221 | 4.54 / 359.95 | 5 | 54 |
9 | 13 | 131.64 | 20 | 15.09 | 514 | 155 | 4.70 / 360.11 | 6 | 46 |
10 | 8 | 0.12 | 244 | 15.08 | 298 | 1096 | 5.79 / 361.20 | 6 | -99 |
Average= | 5.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 16 | 15.09 | 443 | 107 | 0.11 / 349.78 | 6 | 6 |
2 | 10 | 1503.04 | 4 | 14.82 | 2418 | 143 | 0.25 / 349.93 | 5 | 38 |
3 | 10 | 1509.40 | 3 | 14.82 | 2439 | 108 | 0.36 / 350.03 | 5 | 38 |
4 | 7 | 2004.92 | 40 | 14.59 | 3102 | 1810 | 2.17 / 351.84 | 38 | 41 |
5 | 13 | 1975.80 | 20 | 14.57 | 3056 | 891 | 3.06 / 352.73 | 5 | 46 |
6 | 13 | 1494.00 | 20 | 14.64 | 2425 | 710 | 3.77 / 353.44 | 5 | 55 |
7 | 13 | 946.48 | 20 | 14.78 | 1680 | 497 | 4.27 / 353.94 | 5 | 63 |
8 | 13 | 279.88 | 20 | 15.04 | 737 | 222 | 4.49 / 354.16 | 5 | 55 |
9 | 13 | 100.08 | 20 | 15.10 | 465 | 140 | 4.63 / 354.30 | 6 | 43 |
10 | 8 | 0.04 | 244 | 15.09 | 301 | 1108 | 5.74 / 355.41 | 6 | 218 |
Average= | 5.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 16 | 15.10 | 441 | 107 | 0.11 / 343.99 | 6 | 6 |
2 | 10 | 1500.56 | 4 | 14.84 | 2423 | 144 | 0.25 / 344.13 | 5 | 34 |
3 | 10 | 1506.84 | 3 | 14.85 | 2436 | 109 | 0.36 / 344.24 | 5 | 36 |
4 | 7 | 2012.12 | 40 | 14.58 | 3105 | 1811 | 2.17 / 346.05 | 36 | 44 |
5 | 13 | 1981.28 | 20 | 14.57 | 3062 | 892 | 3.06 / 346.94 | 5 | 46 |
6 | 13 | 1514.16 | 20 | 14.64 | 2445 | 716 | 3.78 / 347.66 | 5 | 54 |
7 | 13 | 994.20 | 20 | 14.77 | 1746 | 516 | 4.29 / 348.17 | 5 | 62 |
8 | 13 | 276.04 | 20 | 15.02 | 748 | 225 | 4.52 / 348.40 | 5 | 66 |
9 | 13 | 84.84 | 20 | 15.08 | 458 | 138 | 4.66 / 348.54 | 5 | 57 |
10 | 8 | 0.04 | 244 | 15.07 | 310 | 1140 | 5.80 / 349.68 | 6 | -99 |
Average= | 5.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 16 | 15.11 | 442 | 107 | 0.11 / 338.15 | 6 | 6 |
2 | 10 | 1507.08 | 4 | 14.85 | 2449 | 145 | 0.25 / 338.30 | 5 | 36 |
3 | 10 | 1513.68 | 3 | 14.86 | 2432 | 108 | 0.36 / 338.41 | 5 | 38 |
4 | 7 | 2008.56 | 40 | 14.59 | 3101 | 1810 | 2.17 / 340.22 | 38 | 42 |
5 | 13 | 1976.80 | 20 | 14.57 | 3056 | 891 | 3.06 / 341.11 | 5 | 43 |
6 | 13 | 1613.92 | 20 | 14.61 | 2583 | 755 | 3.82 / 341.86 | 5 | 52 |
7 | 13 | 977.32 | 20 | 14.78 | 1721 | 509 | 4.32 / 342.37 | 5 | 63 |
8 | 13 | 343.04 | 20 | 15.02 | 830 | 249 | 4.57 / 342.62 | 5 | 58 |
9 | 13 | 75.60 | 20 | 15.11 | 430 | 130 | 4.70 / 342.75 | 6 | 43 |
10 | 8 | 0.04 | 246 | 15.09 | 304 | 1128 | 5.83 / 343.88 | 6 | -99 |
Average= | 5.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 16 | 15.12 | 445 | 108 | 0.11 / 332.36 | 6 | 6 |
2 | 10 | 1505.08 | 4 | 14.85 | 2447 | 145 | 0.25 / 332.50 | 5 | 32 |
3 | 10 | 1511.36 | 3 | 14.87 | 2416 | 108 | 0.36 / 332.61 | 5 | 34 |
4 | 7 | 2012.32 | 41 | 14.58 | 3100 | 1853 | 2.21 / 334.47 | 34 | 42 |
5 | 13 | 1981.36 | 20 | 14.56 | 3076 | 896 | 3.11 / 335.36 | 5 | 44 |
6 | 13 | 1594.88 | 20 | 14.62 | 2558 | 748 | 3.86 / 336.11 | 5 | 52 |
7 | 13 | 897.16 | 20 | 14.81 | 1615 | 478 | 4.34 / 336.59 | 5 | 63 |
8 | 13 | 239.40 | 20 | 15.06 | 685 | 206 | 4.54 / 336.79 | 5 | 54 |
9 | 13 | 98.48 | 20 | 15.10 | 466 | 141 | 4.68 / 336.93 | 6 | 46 |
10 | 8 | 0.12 | 244 | 15.09 | 302 | 1112 | 5.79 / 338.05 | 6 | -99 |
Average= | 5.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 16 | 15.12 | 445 | 108 | 0.11 / 326.55 | 6 | 6 |
2 | 10 | 1501.52 | 4 | 14.85 | 2424 | 144 | 0.25 / 326.70 | 5 | 34 |
3 | 10 | 1507.64 | 3 | 14.86 | 2438 | 109 | 0.36 / 326.81 | 5 | 36 |
4 | 7 | 2016.08 | 40 | 14.59 | 3109 | 1814 | 2.17 / 328.62 | 36 | 42 |
5 | 13 | 1988.28 | 20 | 14.57 | 3082 | 898 | 3.07 / 329.52 | 5 | 45 |
6 | 13 | 1567.08 | 20 | 14.63 | 2518 | 737 | 3.81 / 330.26 | 5 | 53 |
7 | 13 | 922.52 | 20 | 14.81 | 1648 | 488 | 4.30 / 330.74 | 5 | 63 |
8 | 13 | 292.76 | 20 | 15.05 | 753 | 227 | 4.52 / 330.97 | 5 | 54 |
9 | 13 | 141.24 | 20 | 15.10 | 527 | 159 | 4.68 / 331.13 | 6 | 46 |
10 | 8 | 0.12 | 246 | 15.09 | 302 | 1121 | 5.80 / 332.25 | 6 | -99 |
Average= | 5.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 16 | 15.12 | 443 | 107 | 0.11 / 320.80 | 6 | 6 |
2 | 10 | 1508.68 | 4 | 14.86 | 2428 | 144 | 0.25 / 320.94 | 5 | 36 |
3 | 10 | 1515.12 | 3 | 14.85 | 2448 | 109 | 0.36 / 321.05 | 5 | 37 |
4 | 7 | 2010.32 | 40 | 14.58 | 3100 | 1808 | 2.17 / 322.86 | 37 | 42 |
5 | 13 | 1980.00 | 20 | 14.57 | 3068 | 894 | 3.06 / 323.75 | 5 | 45 |
6 | 13 | 1593.96 | 20 | 14.62 | 2552 | 746 | 3.81 / 324.50 | 5 | 53 |
7 | 13 | 898.32 | 20 | 14.82 | 1610 | 477 | 4.29 / 324.98 | 5 | 64 |
8 | 13 | 296.72 | 20 | 15.05 | 761 | 229 | 4.51 / 325.21 | 5 | 54 |
9 | 13 | 109.24 | 20 | 15.11 | 476 | 144 | 4.66 / 325.35 | 6 | 43 |
10 | 8 | 0.08 | 244 | 15.10 | 298 | 1098 | 5.76 / 326.45 | 6 | -99 |
Average= | 5.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 16 | 15.12 | 445 | 108 | 0.11 / 315.01 | 6 | 6 |
2 | 10 | 1506.72 | 4 | 14.84 | 2439 | 145 | 0.25 / 315.16 | 5 | 38 |
3 | 10 | 1512.44 | 3 | 14.85 | 2439 | 109 | 0.36 / 315.27 | 5 | 39 |
4 | 7 | 2003.64 | 40 | 14.59 | 3096 | 1807 | 2.17 / 317.07 | 39 | 43 |
5 | 13 | 1973.16 | 20 | 14.58 | 3055 | 891 | 3.06 / 317.96 | 5 | 47 |
6 | 13 | 1514.76 | 20 | 14.65 | 2447 | 717 | 3.78 / 318.68 | 5 | 54 |
7 | 13 | 994.28 | 20 | 14.78 | 1746 | 516 | 4.29 / 319.20 | 5 | 64 |
8 | 13 | 309.84 | 20 | 15.04 | 786 | 236 | 4.53 / 319.43 | 5 | 58 |
9 | 13 | 120.88 | 20 | 15.11 | 501 | 151 | 4.68 / 319.58 | 6 | 47 |
10 | 8 | 0.04 | 244 | 15.10 | 300 | 1105 | 5.78 / 320.69 | 6 | -99 |
Average= | 5.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 16 | 15.10 | 456 | 110 | 0.11 / 309.29 | 6 | 7 |
2 | 10 | 1502.28 | 4 | 14.82 | 2440 | 145 | 0.25 / 309.43 | 5 | 38 |
3 | 10 | 1507.96 | 3 | 14.84 | 2440 | 109 | 0.36 / 309.54 | 5 | 40 |
4 | 7 | 2005.00 | 41 | 14.60 | 3099 | 1855 | 2.22 / 311.40 | 40 | 43 |
5 | 13 | 1974.80 | 20 | 14.58 | 3071 | 896 | 3.11 / 312.29 | 5 | 46 |
6 | 13 | 1442.24 | 20 | 14.68 | 2344 | 688 | 3.80 / 312.98 | 5 | 56 |
7 | 13 | 896.96 | 20 | 14.82 | 1614 | 478 | 4.28 / 313.46 | 5 | 65 |
8 | 13 | 192.20 | 20 | 15.09 | 614 | 185 | 4.47 / 313.64 | 5 | 55 |
9 | 13 | 54.36 | 20 | 15.13 | 404 | 122 | 4.59 / 313.77 | 6 | 47 |
10 | 8 | 0.08 | 242 | 15.10 | 312 | 1140 | 5.73 / 314.91 | 6 | 216 |
Average= | 5.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 16 | 15.12 | 442 | 107 | 0.11 / 303.48 | 6 | 6 |
2 | 10 | 1503.00 | 4 | 14.86 | 2425 | 144 | 0.25 / 303.63 | 5 | 36 |
3 | 10 | 1508.76 | 3 | 14.86 | 2447 | 109 | 0.36 / 303.73 | 5 | 37 |
4 | 7 | 2013.80 | 40 | 14.60 | 3091 | 1805 | 2.17 / 305.54 | 37 | 43 |
5 | 13 | 1984.48 | 20 | 14.59 | 3064 | 894 | 3.06 / 306.43 | 5 | 45 |
6 | 13 | 1627.68 | 20 | 14.63 | 2594 | 759 | 3.82 / 307.19 | 5 | 53 |
7 | 13 | 937.56 | 20 | 14.81 | 1671 | 495 | 4.31 / 307.69 | 5 | 65 |
8 | 13 | 203.76 | 20 | 15.07 | 647 | 195 | 4.51 / 307.88 | 5 | 65 |
9 | 13 | 55.56 | 20 | 15.12 | 419 | 127 | 4.64 / 308.01 | 6 | 55 |
10 | 8 | 0.04 | 242 | 15.08 | 320 | 1168 | 5.80 / 309.18 | 6 | -99 |
Average= | 5.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 16 | 15.12 | 445 | 108 | 0.11 / 297.83 | 6 | 6 |
2 | 10 | 1503.76 | 4 | 14.85 | 2428 | 144 | 0.25 / 297.97 | 5 | 38 |
3 | 10 | 1509.80 | 3 | 14.86 | 2460 | 110 | 0.36 / 298.08 | 5 | 37 |
4 | 7 | 2012.60 | 40 | 14.60 | 3109 | 1816 | 2.18 / 299.90 | 37 | 42 |
5 | 13 | 1982.12 | 20 | 14.58 | 3059 | 892 | 3.07 / 300.79 | 5 | 45 |
6 | 13 | 1422.56 | 20 | 14.69 | 2326 | 683 | 3.75 / 301.47 | 5 | 55 |
7 | 13 | 877.00 | 20 | 14.84 | 1584 | 470 | 4.22 / 301.94 | 5 | 65 |
8 | 13 | 175.16 | 20 | 15.11 | 585 | 177 | 4.40 / 302.12 | 6 | 52 |
9 | 13 | 69.16 | 20 | 15.13 | 425 | 129 | 4.53 / 302.25 | 6 | 46 |
10 | 8 | 0.00 | 242 | 15.10 | 308 | 1125 | 5.65 / 303.37 | 6 | -99 |
Average= | 5.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 16 | 15.13 | 443 | 107 | 0.11 / 292.05 | 6 | 6 |
2 | 10 | 1504.56 | 4 | 14.87 | 2430 | 145 | 0.25 / 292.19 | 5 | 34 |
3 | 10 | 1510.36 | 3 | 14.88 | 2440 | 109 | 0.36 / 292.30 | 5 | 37 |
4 | 7 | 2012.44 | 40 | 14.60 | 3096 | 1808 | 2.17 / 294.11 | 37 | 43 |
5 | 13 | 1981.52 | 20 | 14.58 | 3075 | 897 | 3.07 / 295.01 | 5 | 44 |
6 | 13 | 1581.72 | 20 | 14.65 | 2529 | 741 | 3.81 / 295.75 | 5 | 53 |
7 | 13 | 883.84 | 20 | 14.84 | 1597 | 474 | 4.28 / 296.22 | 5 | 66 |
8 | 13 | 260.00 | 20 | 15.06 | 719 | 217 | 4.50 / 296.44 | 5 | 61 |
9 | 13 | 74.12 | 20 | 15.13 | 439 | 133 | 4.63 / 296.57 | 6 | 49 |
10 | 8 | 0.12 | 242 | 15.10 | 315 | 1151 | 5.78 / 297.72 | 6 | 158 |
Average= | 5.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 16 | 15.12 | 435 | 105 | 0.11 / 286.17 | 6 | 6 |
2 | 10 | 1506.56 | 4 | 14.85 | 2435 | 145 | 0.25 / 286.32 | 5 | 38 |
3 | 10 | 1512.28 | 3 | 14.87 | 2447 | 109 | 0.36 / 286.43 | 5 | 38 |
4 | 7 | 2016.76 | 40 | 14.60 | 3112 | 1817 | 2.18 / 288.25 | 38 | 42 |
5 | 13 | 1987.96 | 20 | 14.59 | 3078 | 898 | 3.07 / 289.14 | 5 | 44 |
6 | 13 | 1642.72 | 20 | 14.63 | 2608 | 763 | 3.84 / 289.91 | 5 | 52 |
7 | 13 | 982.44 | 20 | 14.81 | 1730 | 512 | 4.35 / 290.42 | 5 | 62 |
8 | 13 | 347.60 | 20 | 15.04 | 836 | 251 | 4.60 / 290.67 | 5 | 57 |
9 | 13 | 115.88 | 20 | 15.12 | 489 | 148 | 4.75 / 290.82 | 6 | 46 |
10 | 8 | 0.16 | 244 | 15.11 | 304 | 1121 | 5.87 / 291.94 | 6 | 184 |
Average= | 5.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 16 | 15.11 | 459 | 111 | 0.11 / 280.50 | 6 | 7 |
2 | 10 | 1507.60 | 4 | 14.83 | 2433 | 144 | 0.26 / 280.65 | 5 | 39 |
3 | 7 | 2007.56 | 40 | 14.61 | 3095 | 1809 | 2.06 / 282.45 | 39 | 41 |
4 | 13 | 1977.28 | 20 | 14.60 | 3061 | 894 | 2.96 / 283.35 | 5 | 47 |
5 | 13 | 1480.28 | 20 | 14.68 | 2402 | 705 | 3.66 / 284.05 | 5 | 54 |
6 | 13 | 908.12 | 20 | 14.84 | 1630 | 484 | 4.15 / 284.54 | 5 | 64 |
7 | 13 | 343.00 | 20 | 15.03 | 847 | 255 | 4.40 / 284.79 | 5 | 64 |
8 | 13 | 34.88 | 20 | 15.15 | 381 | 115 | 4.52 / 284.91 | 6 | 48 |
9 | 8 | -0.08 | 242 | 15.10 | 318 | 1162 | 5.68 / 286.07 | 6 | 158 |
Average= | 5.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 16 | 15.13 | 448 | 108 | 0.11 / 274.81 | 6 | 7 |
2 | 10 | 1500.72 | 3 | 14.86 | 2420 | 108 | 0.22 / 274.92 | 5 | 38 |
3 | 7 | 2011.84 | 40 | 14.61 | 3101 | 1812 | 2.03 / 276.73 | 38 | 43 |
4 | 13 | 1982.68 | 20 | 14.60 | 3074 | 898 | 2.93 / 277.63 | 5 | 45 |
5 | 13 | 1629.96 | 20 | 14.64 | 2602 | 762 | 3.69 / 278.39 | 5 | 53 |
6 | 13 | 961.00 | 20 | 14.82 | 1703 | 505 | 4.19 / 278.90 | 5 | 65 |
7 | 13 | 252.76 | 20 | 15.07 | 714 | 215 | 4.41 / 279.11 | 5 | 64 |
8 | 13 | 26.96 | 20 | 15.15 | 376 | 114 | 4.52 / 279.23 | 5 | 56 |
9 | 8 | -0.04 | 240 | 15.10 | 321 | 1163 | 5.69 / 280.39 | 6 | 137 |
Average= | 5.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 16 | 15.14 | 445 | 108 | 0.11 / 269.05 | 6 | 6 |
2 | 10 | 1502.12 | 4 | 14.87 | 2424 | 144 | 0.25 / 269.19 | 5 | 35 |
3 | 10 | 1508.04 | 3 | 14.88 | 2437 | 109 | 0.36 / 269.30 | 5 | 37 |
4 | 7 | 2004.32 | 40 | 14.61 | 3100 | 1812 | 2.17 / 271.11 | 37 | 43 |
5 | 13 | 1974.76 | 20 | 14.60 | 3058 | 893 | 3.07 / 272.01 | 5 | 45 |
6 | 13 | 1545.16 | 20 | 14.67 | 2485 | 729 | 3.79 / 272.74 | 5 | 54 |
7 | 13 | 925.04 | 20 | 14.84 | 1651 | 490 | 4.28 / 273.23 | 5 | 64 |
8 | 13 | 228.48 | 20 | 15.09 | 675 | 204 | 4.49 / 273.43 | 5 | 60 |
9 | 13 | 46.28 | 20 | 15.15 | 398 | 121 | 4.61 / 273.55 | 6 | 51 |
10 | 8 | 0.08 | 242 | 15.11 | 316 | 1155 | 5.76 / 274.71 | 6 | 194 |
Average= | 5.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 16 | 15.15 | 449 | 109 | 0.11 / 263.21 | 6 | 6 |
2 | 10 | 1500.28 | 4 | 14.87 | 2412 | 143 | 0.25 / 263.35 | 5 | 34 |
3 | 10 | 1506.76 | 3 | 14.89 | 2434 | 109 | 0.36 / 263.46 | 5 | 36 |
4 | 7 | 2003.64 | 40 | 14.62 | 3097 | 1811 | 2.17 / 265.27 | 36 | 42 |
5 | 13 | 1975.84 | 20 | 14.60 | 3061 | 894 | 3.07 / 266.16 | 5 | 45 |
6 | 13 | 1555.28 | 20 | 14.67 | 2517 | 738 | 3.80 / 266.90 | 5 | 53 |
7 | 13 | 1030.44 | 20 | 14.80 | 1800 | 533 | 4.34 / 267.43 | 5 | 63 |
8 | 13 | 283.32 | 20 | 15.08 | 749 | 226 | 4.56 / 267.66 | 5 | 55 |
9 | 13 | 96.40 | 20 | 15.14 | 467 | 141 | 4.70 / 267.80 | 6 | 47 |
10 | 8 | 0.00 | 244 | 15.12 | 309 | 1140 | 5.84 / 268.94 | 6 | -99 |
Average= | 5.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 16 | 15.15 | 443 | 107 | 0.11 / 257.39 | 6 | 6 |
2 | 10 | 1508.72 | 4 | 14.87 | 2435 | 145 | 0.25 / 257.53 | 5 | 35 |
3 | 10 | 1514.28 | 3 | 14.88 | 2439 | 109 | 0.36 / 257.64 | 5 | 39 |
4 | 7 | 2007.72 | 40 | 14.61 | 3101 | 1812 | 2.17 / 259.46 | 39 | 42 |
5 | 13 | 1977.88 | 20 | 14.60 | 3078 | 899 | 3.07 / 260.35 | 5 | 46 |
6 | 13 | 1510.04 | 20 | 14.69 | 2443 | 718 | 3.79 / 261.07 | 5 | 54 |
7 | 13 | 961.32 | 20 | 14.84 | 1700 | 505 | 4.29 / 261.58 | 5 | 64 |
8 | 13 | 359.76 | 20 | 15.06 | 855 | 258 | 4.55 / 261.83 | 5 | 57 |
9 | 13 | 94.00 | 20 | 15.15 | 461 | 140 | 4.69 / 261.97 | 6 | 44 |
10 | 8 | 0.08 | 244 | 15.13 | 304 | 1122 | 5.81 / 263.10 | 6 | -99 |
Average= | 5.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 16 | 15.15 | 447 | 108 | 0.11 / 251.71 | 6 | 6 |
2 | 10 | 1504.04 | 4 | 14.87 | 2424 | 144 | 0.25 / 251.85 | 5 | 35 |
3 | 10 | 1509.44 | 2 | 14.90 | 2429 | 72 | 0.32 / 251.92 | 5 | 38 |
4 | 7 | 2011.00 | 40 | 14.61 | 3102 | 1813 | 2.14 / 253.74 | 38 | 41 |
5 | 13 | 1979.24 | 20 | 14.61 | 3060 | 894 | 3.03 / 254.63 | 5 | 46 |
6 | 13 | 1508.56 | 20 | 14.69 | 2433 | 715 | 3.75 / 255.35 | 5 | 54 |
7 | 13 | 907.60 | 20 | 14.85 | 1625 | 483 | 4.23 / 255.83 | 5 | 64 |
8 | 13 | 218.52 | 20 | 15.12 | 646 | 195 | 4.42 / 256.02 | 6 | 50 |
9 | 13 | 110.80 | 20 | 15.15 | 482 | 146 | 4.57 / 256.17 | 6 | 45 |
10 | 8 | 0.04 | 242 | 15.13 | 304 | 1113 | 5.68 / 257.28 | 6 | -99 |
Average= | 5.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 16 | 15.14 | 447 | 108 | 0.11 / 246.04 | 6 | 7 |
2 | 10 | 1500.48 | 4 | 14.87 | 2434 | 145 | 0.25 / 246.18 | 5 | 36 |
3 | 7 | 2004.76 | 40 | 14.62 | 3094 | 1809 | 2.06 / 247.99 | 36 | 43 |
4 | 13 | 1974.76 | 20 | 14.62 | 3054 | 893 | 2.96 / 248.89 | 5 | 46 |
5 | 13 | 1543.88 | 20 | 14.68 | 2481 | 728 | 3.68 / 249.62 | 5 | 54 |
6 | 13 | 927.44 | 20 | 14.85 | 1655 | 492 | 4.18 / 250.11 | 5 | 63 |
7 | 13 | 302.96 | 20 | 15.08 | 774 | 233 | 4.41 / 250.34 | 5 | 57 |
8 | 13 | 78.20 | 20 | 15.16 | 437 | 132 | 4.54 / 250.47 | 6 | 45 |
9 | 8 | 0.08 | 244 | 15.13 | 305 | 1126 | 5.67 / 251.60 | 6 | -99 |
Average= | 5.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 16 | 15.16 | 448 | 109 | 0.11 / 240.32 | 6 | 6 |
2 | 10 | 1506.24 | 4 | 14.89 | 2432 | 145 | 0.25 / 240.47 | 5 | 34 |
3 | 10 | 1512.28 | 3 | 14.89 | 2431 | 109 | 0.36 / 240.58 | 5 | 36 |
4 | 7 | 2009.32 | 40 | 14.61 | 3104 | 1814 | 2.18 / 242.39 | 36 | 43 |
5 | 13 | 1977.88 | 20 | 14.61 | 3064 | 895 | 3.07 / 243.29 | 5 | 46 |
6 | 13 | 1417.36 | 20 | 14.72 | 2316 | 682 | 3.75 / 243.97 | 5 | 55 |
7 | 13 | 936.48 | 20 | 14.85 | 1674 | 497 | 4.25 / 244.47 | 5 | 63 |
8 | 13 | 257.40 | 20 | 15.09 | 718 | 217 | 4.47 / 244.68 | 5 | 59 |
9 | 13 | 33.64 | 20 | 15.17 | 375 | 114 | 4.58 / 244.80 | 6 | 46 |
10 | 8 | 0.04 | 242 | 15.13 | 310 | 1135 | 5.72 / 245.93 | 6 | -99 |
Average= | 5.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 16 | 15.16 | 447 | 108 | 0.11 / 234.52 | 6 | 7 |
2 | 10 | 1505.28 | 4 | 14.88 | 2428 | 145 | 0.25 / 234.67 | 5 | 37 |
3 | 10 | 1511.36 | 3 | 14.88 | 2460 | 110 | 0.36 / 234.78 | 5 | 38 |
4 | 7 | 2015.36 | 41 | 14.61 | 3113 | 1865 | 2.23 / 236.64 | 38 | 43 |
5 | 13 | 1986.12 | 20 | 14.61 | 3080 | 900 | 3.13 / 237.54 | 5 | 45 |
6 | 13 | 1489.64 | 20 | 14.71 | 2415 | 710 | 3.84 / 238.25 | 5 | 56 |
7 | 13 | 911.04 | 20 | 14.86 | 1637 | 487 | 4.32 / 238.74 | 5 | 64 |
8 | 13 | 285.72 | 20 | 15.10 | 745 | 225 | 4.55 / 238.96 | 5 | 53 |
9 | 13 | 101.44 | 20 | 15.16 | 468 | 142 | 4.69 / 239.10 | 6 | 43 |
10 | 8 | 0.08 | 242 | 15.15 | 303 | 1111 | 5.80 / 240.22 | 6 | -99 |
Average= | 5.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 16 | 15.16 | 445 | 108 | 0.11 / 228.95 | 6 | 7 |
2 | 10 | 1503.08 | 4 | 14.87 | 2437 | 145 | 0.25 / 229.10 | 5 | 38 |
3 | 7 | 2011.60 | 40 | 14.62 | 3106 | 1816 | 2.07 / 230.91 | 38 | 44 |
4 | 13 | 1982.88 | 20 | 14.61 | 3070 | 897 | 2.97 / 231.81 | 5 | 46 |
5 | 13 | 1398.76 | 20 | 14.74 | 2294 | 676 | 3.64 / 232.49 | 5 | 58 |
6 | 13 | 830.24 | 20 | 14.89 | 1522 | 453 | 4.10 / 232.94 | 5 | 65 |
7 | 13 | 265.84 | 20 | 15.10 | 719 | 217 | 4.31 / 233.16 | 5 | 57 |
8 | 13 | 78.08 | 20 | 15.17 | 435 | 132 | 4.44 / 233.29 | 6 | 46 |
9 | 8 | 0.12 | 240 | 15.14 | 309 | 1123 | 5.57 / 234.41 | 6 | 148 |
Average= | 5.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 16 | 15.15 | 449 | 109 | 0.11 / 223.19 | 6 | 7 |
2 | 10 | 1506.12 | 4 | 14.86 | 2449 | 146 | 0.25 / 223.34 | 5 | 37 |
3 | 10 | 1512.00 | 3 | 14.88 | 2458 | 110 | 0.36 / 223.45 | 5 | 38 |
4 | 7 | 2014.44 | 40 | 14.62 | 3114 | 1821 | 2.19 / 225.27 | 38 | 42 |
5 | 13 | 1983.48 | 20 | 14.62 | 3080 | 901 | 3.09 / 226.17 | 5 | 45 |
6 | 13 | 1452.44 | 20 | 14.72 | 2359 | 694 | 3.78 / 226.86 | 5 | 55 |
7 | 13 | 1001.84 | 20 | 14.83 | 1758 | 521 | 4.30 / 227.38 | 5 | 63 |
8 | 13 | 198.28 | 20 | 15.13 | 628 | 190 | 4.49 / 227.57 | 5 | 58 |
9 | 13 | 90.48 | 20 | 15.16 | 462 | 140 | 4.63 / 227.71 | 6 | 51 |
10 | 8 | 0.20 | 242 | 15.14 | 309 | 1132 | 5.76 / 228.85 | 6 | -99 |
Average= | 5.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 16 | 15.15 | 463 | 112 | 0.11 / 217.49 | 6 | 7 |
2 | 10 | 1500.52 | 4 | 14.87 | 2427 | 144 | 0.26 / 217.63 | 5 | 39 |
3 | 7 | 2014.36 | 40 | 14.62 | 3118 | 1823 | 2.08 / 219.46 | 39 | 43 |
4 | 13 | 1982.24 | 20 | 14.62 | 3068 | 897 | 2.98 / 220.35 | 5 | 46 |
5 | 13 | 1475.44 | 20 | 14.72 | 2399 | 706 | 3.68 / 221.06 | 5 | 55 |
6 | 13 | 997.72 | 20 | 14.84 | 1752 | 520 | 4.20 / 221.58 | 5 | 64 |
7 | 13 | 232.84 | 20 | 15.12 | 684 | 207 | 4.41 / 221.79 | 5 | 59 |
8 | 13 | 82.48 | 20 | 15.17 | 454 | 138 | 4.55 / 221.92 | 6 | 50 |
9 | 8 | 0.08 | 242 | 15.14 | 316 | 1158 | 5.71 / 223.08 | 6 | -99 |
Average= | 5.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 16 | 15.14 | 469 | 114 | 0.11 / 211.74 | 6 | 9 |
2 | 10 | 1508.00 | 4 | 14.86 | 2438 | 145 | 0.26 / 211.88 | 5 | 41 |
3 | 7 | 2003.64 | 40 | 14.64 | 3094 | 1812 | 2.07 / 213.69 | 41 | 44 |
4 | 13 | 1975.28 | 20 | 14.63 | 3071 | 899 | 2.97 / 214.59 | 5 | 46 |
5 | 13 | 1700.60 | 20 | 14.66 | 2698 | 791 | 3.76 / 215.38 | 5 | 52 |
6 | 13 | 923.80 | 20 | 14.87 | 1659 | 493 | 4.25 / 215.88 | 5 | 65 |
7 | 13 | 224.60 | 20 | 15.12 | 676 | 204 | 4.46 / 216.08 | 5 | 60 |
8 | 13 | 36.32 | 20 | 15.18 | 390 | 118 | 4.58 / 216.20 | 6 | 51 |
9 | 8 | 0.04 | 242 | 15.14 | 321 | 1176 | 5.75 / 217.38 | 6 | -99 |
Average= | 5.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 16 | 15.15 | 474 | 115 | 0.11 / 205.90 | 6 | 9 |
2 | 10 | 1501.44 | 4 | 14.85 | 2450 | 146 | 0.26 / 206.05 | 5 | 40 |
3 | 10 | 1507.36 | 3 | 14.86 | 2457 | 110 | 0.37 / 206.16 | 5 | 40 |
4 | 7 | 2013.12 | 40 | 14.63 | 3106 | 1818 | 2.19 / 207.98 | 40 | 43 |
5 | 13 | 1980.40 | 20 | 14.62 | 3072 | 898 | 3.09 / 208.88 | 5 | 47 |
6 | 13 | 1499.28 | 20 | 14.72 | 2420 | 712 | 3.80 / 209.59 | 5 | 56 |
7 | 13 | 944.96 | 20 | 14.86 | 1687 | 501 | 4.30 / 210.09 | 5 | 66 |
8 | 13 | 334.68 | 20 | 15.07 | 836 | 252 | 4.55 / 210.34 | 5 | 68 |
9 | 8 | 0.08 | 259 | 15.14 | 327 | 1282 | 5.83 / 211.62 | 6 | 193 |
Average= | 5.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 16 | 15.16 | 462 | 112 | 0.11 / 200.13 | 6 | 7 |
2 | 10 | 1505.52 | 4 | 14.86 | 2442 | 145 | 0.26 / 200.28 | 5 | 39 |
3 | 10 | 1511.64 | 3 | 14.87 | 2442 | 109 | 0.37 / 200.39 | 5 | 40 |
4 | 7 | 2013.52 | 40 | 14.64 | 3115 | 1824 | 2.19 / 202.21 | 40 | 44 |
5 | 13 | 1983.92 | 20 | 14.63 | 3081 | 902 | 3.09 / 203.11 | 5 | 45 |
6 | 13 | 1527.12 | 20 | 14.72 | 2470 | 727 | 3.82 / 203.84 | 5 | 54 |
7 | 13 | 860.16 | 20 | 14.89 | 1570 | 468 | 4.29 / 204.31 | 5 | 66 |
8 | 13 | 233.12 | 20 | 15.12 | 696 | 210 | 4.50 / 204.52 | 5 | 64 |
9 | 8 | 0.12 | 259 | 15.14 | 324 | 1270 | 5.77 / 205.79 | 6 | 138 |
Average= | 5.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 16 | 15.17 | 450 | 109 | 0.11 / 194.41 | 6 | 7 |
2 | 10 | 1502.68 | 4 | 14.89 | 2422 | 144 | 0.25 / 194.56 | 5 | 38 |
3 | 10 | 1508.32 | 3 | 14.89 | 2448 | 109 | 0.36 / 194.67 | 5 | 38 |
4 | 7 | 2003.52 | 40 | 14.63 | 3103 | 1816 | 2.18 / 196.48 | 38 | 43 |
5 | 13 | 1973.12 | 20 | 14.62 | 3073 | 899 | 3.08 / 197.38 | 5 | 46 |
6 | 13 | 1429.72 | 20 | 14.75 | 2342 | 691 | 3.77 / 198.07 | 5 | 55 |
7 | 13 | 881.52 | 20 | 14.89 | 1595 | 475 | 4.24 / 198.55 | 5 | 65 |
8 | 13 | 202.28 | 20 | 15.13 | 645 | 195 | 4.44 / 198.74 | 5 | 62 |
9 | 13 | 23.04 | 20 | 15.19 | 371 | 113 | 4.55 / 198.85 | 6 | 53 |
10 | 8 | -0.08 | 238 | 15.15 | 324 | 1168 | 5.72 / 200.02 | 6 | 165 |
Average= | 5.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 16 | 15.18 | 459 | 111 | 0.11 / 188.57 | 6 | 7 |
2 | 10 | 1508.56 | 4 | 14.90 | 2434 | 145 | 0.26 / 188.72 | 5 | 37 |
3 | 10 | 1514.68 | 3 | 14.91 | 2446 | 109 | 0.37 / 188.83 | 5 | 37 |
4 | 7 | 2012.88 | 40 | 14.64 | 3106 | 1819 | 2.18 / 190.65 | 37 | 43 |
5 | 13 | 1982.00 | 20 | 14.63 | 3071 | 899 | 3.08 / 191.55 | 5 | 44 |
6 | 13 | 1483.28 | 20 | 14.73 | 2411 | 710 | 3.79 / 192.26 | 5 | 54 |
7 | 13 | 999.32 | 20 | 14.85 | 1753 | 521 | 4.31 / 192.78 | 5 | 63 |
8 | 13 | 315.92 | 20 | 15.10 | 800 | 242 | 4.56 / 193.02 | 5 | 60 |
9 | 13 | 78.96 | 20 | 15.18 | 446 | 135 | 4.69 / 193.15 | 6 | 48 |
10 | 8 | 0.08 | 242 | 15.16 | 313 | 1148 | 5.84 / 194.30 | 6 | -99 |
Average= | 5.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 16 | 15.18 | 447 | 109 | 0.11 / 182.70 | 6 | 7 |
2 | 10 | 1506.32 | 4 | 14.91 | 2445 | 146 | 0.25 / 182.84 | 5 | 35 |
3 | 10 | 1512.16 | 3 | 14.92 | 2429 | 109 | 0.36 / 182.95 | 5 | 37 |
4 | 7 | 2011.84 | 40 | 14.64 | 3114 | 1824 | 2.19 / 184.77 | 37 | 42 |
5 | 13 | 1982.64 | 20 | 14.64 | 3080 | 902 | 3.09 / 185.68 | 5 | 45 |
6 | 13 | 1461.80 | 20 | 14.74 | 2378 | 701 | 3.79 / 186.38 | 5 | 54 |
7 | 13 | 1058.36 | 20 | 14.84 | 1835 | 545 | 4.33 / 186.92 | 5 | 62 |
8 | 13 | 407.28 | 20 | 15.07 | 932 | 281 | 4.62 / 187.20 | 5 | 60 |
9 | 13 | 65.36 | 20 | 15.20 | 417 | 127 | 4.74 / 187.33 | 6 | 42 |
10 | 8 | 0.00 | 242 | 15.17 | 309 | 1134 | 5.88 / 188.46 | 6 | 193 |
Average= | 5.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 16 | 15.19 | 456 | 111 | 0.11 / 176.88 | 6 | 7 |
2 | 10 | 1505.80 | 4 | 14.91 | 2446 | 146 | 0.26 / 177.02 | 5 | 36 |
3 | 10 | 1511.24 | 3 | 14.92 | 2474 | 111 | 0.37 / 177.13 | 5 | 37 |
4 | 7 | 2012.04 | 40 | 14.65 | 3106 | 1820 | 2.19 / 178.95 | 37 | 42 |
5 | 13 | 1982.04 | 20 | 14.64 | 3078 | 901 | 3.09 / 179.86 | 5 | 46 |
6 | 13 | 1528.40 | 20 | 14.73 | 2467 | 727 | 3.82 / 180.58 | 5 | 53 |
7 | 13 | 927.56 | 20 | 14.89 | 1656 | 493 | 4.31 / 181.08 | 5 | 64 |
8 | 13 | 334.40 | 20 | 15.11 | 819 | 248 | 4.56 / 181.32 | 5 | 57 |
9 | 13 | 105.48 | 20 | 15.19 | 483 | 147 | 4.70 / 181.47 | 6 | 43 |
10 | 8 | 0.04 | 242 | 15.18 | 304 | 1117 | 5.82 / 182.59 | 6 | -99 |
Average= | 5.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 16 | 15.19 | 450 | 109 | 0.11 / 171.09 | 6 | 7 |
2 | 10 | 1506.04 | 4 | 14.92 | 2419 | 144 | 0.25 / 171.24 | 5 | 34 |
3 | 10 | 1512.20 | 3 | 14.92 | 2460 | 110 | 0.36 / 171.35 | 5 | 37 |
4 | 7 | 2014.72 | 40 | 14.64 | 3111 | 1822 | 2.19 / 173.17 | 37 | 43 |
5 | 13 | 1983.40 | 20 | 14.65 | 3081 | 903 | 3.09 / 174.07 | 5 | 46 |
6 | 13 | 1498.00 | 20 | 14.74 | 2424 | 715 | 3.80 / 174.79 | 5 | 54 |
7 | 13 | 906.64 | 20 | 14.90 | 1625 | 484 | 4.29 / 175.27 | 5 | 64 |
8 | 13 | 235.00 | 20 | 15.16 | 676 | 205 | 4.49 / 175.48 | 6 | 50 |
9 | 13 | 128.08 | 20 | 15.19 | 509 | 155 | 4.65 / 175.63 | 6 | 44 |
10 | 8 | -0.04 | 242 | 15.18 | 309 | 1135 | 5.78 / 176.77 | 6 | -99 |
Average= | 5.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 16 | 15.19 | 449 | 109 | 0.11 / 165.26 | 6 | 7 |
2 | 10 | 1503.72 | 4 | 14.89 | 2448 | 146 | 0.25 / 165.41 | 5 | 38 |
3 | 10 | 1509.68 | 3 | 14.91 | 2461 | 110 | 0.37 / 165.52 | 5 | 39 |
4 | 7 | 2013.80 | 40 | 14.65 | 3117 | 1827 | 2.19 / 167.34 | 39 | 43 |
5 | 13 | 1982.80 | 20 | 14.64 | 3084 | 903 | 3.09 / 168.25 | 5 | 44 |
6 | 13 | 1547.36 | 20 | 14.73 | 2487 | 733 | 3.83 / 168.98 | 5 | 54 |
7 | 13 | 986.92 | 20 | 14.87 | 1737 | 517 | 4.34 / 169.49 | 5 | 63 |
8 | 13 | 240.20 | 20 | 15.16 | 680 | 206 | 4.55 / 169.70 | 6 | 50 |
9 | 13 | 132.16 | 20 | 15.19 | 516 | 157 | 4.71 / 169.86 | 6 | 44 |
10 | 8 | 0.16 | 242 | 15.18 | 307 | 1128 | 5.83 / 170.99 | 6 | -99 |
Average= | 5.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 16 | 15.17 | 460 | 112 | 0.11 / 159.35 | 6 | 9 |
2 | 10 | 1502.60 | 4 | 14.87 | 2444 | 145 | 0.26 / 159.50 | 5 | 41 |
3 | 10 | 1508.40 | 3 | 14.89 | 2478 | 111 | 0.37 / 159.61 | 5 | 42 |
4 | 7 | 2014.44 | 40 | 14.65 | 3118 | 1827 | 2.19 / 161.44 | 42 | 44 |
5 | 13 | 1983.88 | 20 | 14.66 | 3071 | 900 | 3.10 / 162.34 | 5 | 47 |
6 | 13 | 1630.12 | 20 | 14.71 | 2612 | 768 | 3.86 / 163.10 | 5 | 52 |
7 | 13 | 1018.92 | 20 | 14.86 | 1791 | 532 | 4.40 / 163.64 | 5 | 62 |
8 | 13 | 271.72 | 20 | 15.13 | 751 | 227 | 4.62 / 163.86 | 5 | 61 |
9 | 13 | 53.28 | 20 | 15.21 | 413 | 126 | 4.75 / 163.99 | 6 | 48 |
10 | 8 | 0.08 | 240 | 15.17 | 319 | 1161 | 5.91 / 165.15 | 6 | 215 |
Average= | 5.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 16 | 15.19 | 448 | 109 | 0.11 / 153.62 | 6 | 7 |
2 | 10 | 1505.32 | 4 | 14.90 | 2460 | 147 | 0.26 / 153.77 | 5 | 38 |
3 | 10 | 1510.92 | 3 | 14.91 | 2478 | 111 | 0.37 / 153.88 | 5 | 39 |
4 | 7 | 2004.48 | 40 | 14.65 | 3107 | 1821 | 2.19 / 155.70 | 39 | 42 |
5 | 13 | 1977.12 | 20 | 14.65 | 3079 | 902 | 3.09 / 156.60 | 5 | 47 |
6 | 13 | 1434.56 | 20 | 14.77 | 2340 | 691 | 3.78 / 157.29 | 5 | 55 |
7 | 13 | 900.40 | 20 | 14.90 | 1631 | 486 | 4.27 / 157.78 | 5 | 66 |
8 | 13 | 156.64 | 20 | 15.17 | 588 | 178 | 4.44 / 157.95 | 5 | 62 |
9 | 8 | 0.12 | 257 | 15.16 | 330 | 1286 | 5.73 / 159.24 | 6 | 144 |
Average= | 5.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 16 | 15.19 | 455 | 111 | 0.11 / 147.90 | 6 | 7 |
2 | 10 | 1505.04 | 4 | 14.89 | 2461 | 147 | 0.26 / 148.04 | 5 | 38 |
3 | 10 | 1511.12 | 3 | 14.90 | 2461 | 110 | 0.37 / 148.15 | 5 | 39 |
4 | 7 | 2008.00 | 40 | 14.66 | 3109 | 1823 | 2.19 / 149.98 | 39 | 43 |
5 | 13 | 1978.72 | 20 | 14.66 | 3080 | 903 | 3.09 / 150.88 | 5 | 46 |
6 | 13 | 1455.72 | 20 | 14.77 | 2371 | 700 | 3.79 / 151.58 | 5 | 55 |
7 | 13 | 837.68 | 20 | 14.94 | 1536 | 459 | 4.25 / 152.04 | 5 | 65 |
8 | 13 | 249.36 | 20 | 15.15 | 704 | 213 | 4.47 / 152.25 | 5 | 56 |
9 | 13 | 31.72 | 20 | 15.23 | 370 | 113 | 4.58 / 152.37 | 6 | 44 |
10 | 8 | -0.04 | 240 | 15.18 | 314 | 1144 | 5.72 / 153.51 | 6 | -99 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 16 | 15.18 | 476 | 116 | 0.12 / 142.28 | 6 | 10 |
2 | 10 | 1506.40 | 4 | 14.87 | 2466 | 147 | 0.26 / 142.43 | 5 | 42 |
3 | 7 | 2007.52 | 40 | 14.66 | 3110 | 1824 | 2.09 / 144.25 | 42 | 44 |
4 | 13 | 1941.44 | 20 | 14.67 | 3023 | 887 | 2.97 / 145.14 | 5 | 47 |
5 | 13 | 1442.12 | 20 | 14.77 | 2366 | 699 | 3.67 / 145.84 | 5 | 57 |
6 | 13 | 779.24 | 20 | 14.95 | 1458 | 436 | 4.11 / 146.28 | 5 | 65 |
7 | 13 | 304.56 | 20 | 15.12 | 793 | 240 | 4.35 / 146.52 | 5 | 64 |
8 | 13 | 34.52 | 20 | 15.22 | 381 | 116 | 4.46 / 146.63 | 6 | 50 |
9 | 8 | 0.08 | 238 | 15.18 | 320 | 1156 | 5.62 / 147.79 | 6 | 151 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 16 | 15.20 | 453 | 110 | 0.11 / 136.69 | 6 | 7 |
2 | 10 | 1503.72 | 4 | 14.92 | 2440 | 146 | 0.26 / 136.84 | 5 | 38 |
3 | 7 | 2010.92 | 40 | 14.66 | 3112 | 1825 | 2.08 / 138.66 | 38 | 44 |
4 | 13 | 1979.24 | 20 | 14.66 | 3076 | 902 | 2.98 / 139.57 | 5 | 47 |
5 | 13 | 1338.20 | 20 | 14.80 | 2221 | 657 | 3.64 / 140.22 | 5 | 58 |
6 | 13 | 969.84 | 20 | 14.88 | 1719 | 512 | 4.15 / 140.73 | 5 | 65 |
7 | 13 | 117.04 | 20 | 15.19 | 531 | 161 | 4.31 / 140.90 | 5 | 62 |
8 | 8 | -0.04 | 257 | 15.18 | 326 | 1272 | 5.58 / 142.17 | 6 | 175 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 16 | 15.20 | 472 | 115 | 0.11 / 131.04 | 6 | 7 |
2 | 10 | 1504.72 | 4 | 14.93 | 2433 | 145 | 0.26 / 131.18 | 5 | 36 |
3 | 7 | 2007.80 | 40 | 14.67 | 3103 | 1821 | 2.08 / 133.00 | 36 | 43 |
4 | 13 | 1942.44 | 20 | 14.68 | 3030 | 890 | 2.97 / 133.89 | 5 | 46 |
5 | 13 | 1468.40 | 20 | 14.77 | 2392 | 707 | 3.68 / 134.60 | 5 | 55 |
6 | 13 | 945.32 | 20 | 14.91 | 1672 | 499 | 4.18 / 135.10 | 5 | 62 |
7 | 13 | 194.24 | 20 | 15.18 | 629 | 191 | 4.37 / 135.29 | 5 | 52 |
8 | 13 | 87.44 | 20 | 15.22 | 461 | 140 | 4.51 / 135.43 | 6 | 46 |
9 | 8 | 0.12 | 240 | 15.19 | 316 | 1152 | 5.66 / 136.58 | 6 | -99 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 16 | 15.21 | 448 | 109 | 0.11 / 125.25 | 6 | 7 |
2 | 10 | 1506.80 | 4 | 14.93 | 2438 | 146 | 0.25 / 125.40 | 5 | 38 |
3 | 10 | 1512.20 | 3 | 14.94 | 2458 | 110 | 0.36 / 125.51 | 5 | 39 |
4 | 7 | 2015.12 | 40 | 14.67 | 3113 | 1827 | 2.19 / 127.33 | 39 | 44 |
5 | 13 | 1983.76 | 20 | 14.67 | 3077 | 903 | 3.09 / 128.24 | 5 | 44 |
6 | 13 | 1471.20 | 20 | 14.77 | 2393 | 707 | 3.80 / 128.94 | 5 | 54 |
7 | 13 | 848.24 | 20 | 14.94 | 1550 | 463 | 4.26 / 129.41 | 5 | 65 |
8 | 13 | 285.00 | 20 | 15.15 | 752 | 228 | 4.49 / 129.63 | 5 | 55 |
9 | 13 | 94.00 | 20 | 15.22 | 465 | 142 | 4.63 / 129.77 | 6 | 45 |
10 | 8 | -0.04 | 240 | 15.20 | 315 | 1149 | 5.78 / 130.92 | 6 | 224 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 16 | 15.21 | 456 | 111 | 0.11 / 119.55 | 6 | 7 |
2 | 10 | 1504.00 | 3 | 14.92 | 2449 | 110 | 0.22 / 119.66 | 5 | 40 |
3 | 7 | 2015.44 | 41 | 14.67 | 3121 | 1877 | 2.10 / 121.53 | 40 | 44 |
4 | 13 | 1986.12 | 20 | 14.67 | 3077 | 903 | 3.00 / 122.44 | 5 | 47 |
5 | 13 | 1498.16 | 20 | 14.77 | 2423 | 716 | 3.72 / 123.15 | 5 | 55 |
6 | 13 | 918.56 | 20 | 14.92 | 1636 | 488 | 4.20 / 123.64 | 5 | 63 |
7 | 13 | 285.52 | 20 | 15.15 | 752 | 228 | 4.43 / 123.87 | 5 | 57 |
8 | 13 | 92.92 | 20 | 15.22 | 465 | 142 | 4.57 / 124.01 | 6 | 46 |
9 | 8 | 0.12 | 240 | 15.20 | 310 | 1131 | 5.70 / 125.14 | 6 | -99 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 16 | 15.21 | 461 | 112 | 0.11 / 113.74 | 6 | 7 |
2 | 10 | 1507.56 | 4 | 14.91 | 2463 | 147 | 0.26 / 113.89 | 5 | 39 |
3 | 10 | 1513.12 | 3 | 14.92 | 2463 | 110 | 0.37 / 114.00 | 5 | 40 |
4 | 7 | 2015.08 | 40 | 14.68 | 3125 | 1835 | 2.20 / 115.83 | 40 | 44 |
5 | 13 | 1984.92 | 20 | 14.68 | 3087 | 906 | 3.11 / 116.74 | 5 | 46 |
6 | 13 | 1496.80 | 20 | 14.77 | 2431 | 718 | 3.83 / 117.46 | 5 | 55 |
7 | 13 | 813.08 | 20 | 14.95 | 1516 | 453 | 4.28 / 117.91 | 5 | 66 |
8 | 13 | 265.24 | 20 | 15.15 | 741 | 225 | 4.51 / 118.14 | 5 | 61 |
9 | 13 | 44.44 | 20 | 15.23 | 406 | 124 | 4.63 / 118.26 | 6 | 47 |
10 | 8 | 0.16 | 240 | 15.19 | 323 | 1178 | 5.81 / 119.44 | 6 | -99 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 16 | 15.22 | 444 | 108 | 0.11 / 108.18 | 6 | 7 |
2 | 10 | 1504.28 | 3 | 14.93 | 2443 | 109 | 0.22 / 108.29 | 5 | 38 |
3 | 7 | 2010.68 | 40 | 14.68 | 3120 | 1832 | 2.05 / 110.13 | 38 | 44 |
4 | 13 | 1980.28 | 20 | 14.68 | 3076 | 903 | 2.95 / 111.03 | 5 | 46 |
5 | 13 | 1407.60 | 20 | 14.80 | 2318 | 686 | 3.64 / 111.72 | 5 | 57 |
6 | 13 | 783.64 | 20 | 14.97 | 1467 | 439 | 4.08 / 112.15 | 5 | 66 |
7 | 13 | 188.76 | 20 | 15.19 | 620 | 188 | 4.27 / 112.34 | 5 | 57 |
8 | 13 | 45.08 | 20 | 15.24 | 400 | 122 | 4.39 / 112.46 | 6 | 47 |
9 | 8 | -0.04 | 240 | 15.20 | 319 | 1164 | 5.55 / 113.63 | 6 | -99 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 16 | 15.22 | 460 | 112 | 0.11 / 102.43 | 6 | 7 |
2 | 10 | 1506.28 | 4 | 14.93 | 2447 | 146 | 0.26 / 102.58 | 5 | 38 |
3 | 7 | 2013.48 | 41 | 14.68 | 3127 | 1882 | 2.14 / 104.46 | 38 | 44 |
4 | 13 | 1982.88 | 20 | 14.69 | 3081 | 905 | 3.05 / 105.37 | 5 | 47 |
5 | 13 | 1525.84 | 20 | 14.76 | 2479 | 732 | 3.78 / 106.10 | 5 | 55 |
6 | 13 | 889.12 | 20 | 14.93 | 1616 | 483 | 4.26 / 106.58 | 5 | 66 |
7 | 13 | 246.76 | 20 | 15.17 | 709 | 215 | 4.47 / 106.80 | 5 | 60 |
8 | 13 | 62.96 | 20 | 15.23 | 425 | 129 | 4.60 / 106.93 | 6 | 47 |
9 | 8 | 0.08 | 240 | 15.21 | 315 | 1150 | 5.75 / 108.08 | 6 | -99 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 16 | 15.22 | 462 | 113 | 0.11 / 96.83 | 6 | 8 |
2 | 10 | 1501.64 | 4 | 14.93 | 2436 | 145 | 0.26 / 96.98 | 5 | 40 |
3 | 7 | 2004.56 | 41 | 14.69 | 3106 | 1871 | 2.13 / 98.85 | 40 | 45 |
4 | 13 | 1972.48 | 20 | 14.69 | 3065 | 900 | 3.03 / 99.75 | 5 | 47 |
5 | 13 | 1426.56 | 20 | 14.80 | 2326 | 688 | 3.72 / 100.44 | 5 | 56 |
6 | 13 | 742.48 | 20 | 15.00 | 1412 | 424 | 4.14 / 100.86 | 5 | 66 |
7 | 13 | 162.04 | 20 | 15.21 | 584 | 178 | 4.32 / 101.04 | 5 | 56 |
8 | 13 | 59.64 | 20 | 15.24 | 424 | 129 | 4.45 / 101.17 | 6 | 50 |
9 | 8 | 0.12 | 238 | 15.21 | 319 | 1155 | 5.60 / 102.32 | 6 | -99 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 16 | 15.21 | 471 | 115 | 0.11 / 91.14 | 6 | 8 |
2 | 10 | 1507.52 | 4 | 14.92 | 2457 | 147 | 0.26 / 91.29 | 5 | 40 |
3 | 7 | 2004.48 | 40 | 14.70 | 3103 | 1825 | 2.09 / 93.11 | 40 | 44 |
4 | 13 | 1973.28 | 20 | 14.71 | 3060 | 900 | 2.99 / 94.01 | 5 | 47 |
5 | 13 | 1464.20 | 20 | 14.80 | 2381 | 705 | 3.69 / 94.72 | 5 | 55 |
6 | 13 | 905.84 | 20 | 14.94 | 1639 | 490 | 4.18 / 95.21 | 5 | 65 |
7 | 13 | 195.80 | 20 | 15.19 | 645 | 196 | 4.38 / 95.40 | 5 | 63 |
8 | 13 | 49.40 | 20 | 15.24 | 419 | 128 | 4.50 / 95.53 | 6 | 55 |
9 | 8 | 0.08 | 238 | 15.20 | 329 | 1190 | 5.69 / 96.72 | 6 | 227 |
Average= | 5.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 16 | 15.22 | 473 | 115 | 0.12 / 85.47 | 6 | 7 |
2 | 10 | 1507.00 | 4 | 14.93 | 2435 | 145 | 0.26 / 85.62 | 5 | 40 |
3 | 7 | 2011.52 | 40 | 14.71 | 3122 | 1837 | 2.10 / 87.45 | 40 | 43 |
4 | 13 | 1980.72 | 20 | 14.70 | 3088 | 908 | 3.01 / 88.36 | 5 | 47 |
5 | 13 | 1478.24 | 20 | 14.79 | 2403 | 711 | 3.72 / 89.07 | 5 | 55 |
6 | 13 | 849.84 | 20 | 14.96 | 1545 | 462 | 4.18 / 89.53 | 5 | 65 |
7 | 13 | 188.68 | 20 | 15.19 | 637 | 194 | 4.37 / 89.73 | 5 | 63 |
8 | 13 | 34.48 | 20 | 15.24 | 400 | 122 | 4.49 / 89.85 | 6 | 56 |
9 | 8 | 0.08 | 235 | 15.20 | 329 | 1175 | 5.67 / 91.02 | 6 | 144 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 16 | 15.23 | 452 | 110 | 0.11 / 79.86 | 6 | 7 |
2 | 10 | 1500.96 | 3 | 14.94 | 2420 | 108 | 0.22 / 79.97 | 5 | 40 |
3 | 7 | 2010.40 | 40 | 14.71 | 3114 | 1832 | 2.05 / 81.80 | 40 | 45 |
4 | 13 | 1980.84 | 20 | 14.72 | 3079 | 906 | 2.96 / 82.71 | 5 | 47 |
5 | 13 | 1418.00 | 20 | 14.82 | 2330 | 691 | 3.65 / 83.40 | 5 | 56 |
6 | 13 | 801.84 | 20 | 14.98 | 1491 | 447 | 4.09 / 83.85 | 5 | 66 |
7 | 13 | 239.92 | 20 | 15.18 | 706 | 214 | 4.31 / 84.06 | 5 | 64 |
8 | 13 | 22.24 | 20 | 15.25 | 374 | 114 | 4.42 / 84.18 | 6 | 54 |
9 | 8 | -0.12 | 238 | 15.21 | 326 | 1180 | 5.60 / 85.36 | 6 | 252 |
Average= | 5.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 16 | 15.23 | 460 | 112 | 0.11 / 74.25 | 6 | 7 |
2 | 10 | 1507.00 | 3 | 14.94 | 2445 | 110 | 0.22 / 74.36 | 5 | 40 |
3 | 7 | 2009.64 | 40 | 14.71 | 3116 | 1833 | 2.06 / 76.19 | 40 | 43 |
4 | 13 | 1979.24 | 20 | 14.72 | 3077 | 906 | 2.96 / 77.10 | 5 | 46 |
5 | 13 | 1518.24 | 20 | 14.79 | 2457 | 727 | 3.69 / 77.83 | 5 | 54 |
6 | 13 | 828.36 | 20 | 14.97 | 1528 | 457 | 4.15 / 78.28 | 5 | 65 |
7 | 13 | 168.56 | 20 | 15.21 | 600 | 183 | 4.33 / 78.47 | 5 | 59 |
8 | 13 | 34.40 | 20 | 15.25 | 394 | 120 | 4.45 / 78.59 | 6 | 51 |
9 | 8 | 0.08 | 238 | 15.22 | 322 | 1166 | 5.61 / 79.75 | 6 | 193 |
Average= | 5.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 16 | 15.23 | 454 | 111 | 0.11 / 68.58 | 6 | 7 |
2 | 10 | 1504.08 | 3 | 14.94 | 2459 | 110 | 0.22 / 68.69 | 5 | 39 |
3 | 7 | 2003.60 | 40 | 14.73 | 3104 | 1829 | 2.05 / 70.52 | 39 | 43 |
4 | 13 | 1973.12 | 20 | 14.72 | 3073 | 905 | 2.95 / 71.42 | 5 | 46 |
5 | 13 | 1482.08 | 20 | 14.81 | 2407 | 713 | 3.67 / 72.13 | 5 | 55 |
6 | 13 | 916.44 | 20 | 14.95 | 1641 | 491 | 4.16 / 72.62 | 5 | 64 |
7 | 13 | 178.24 | 20 | 15.21 | 622 | 189 | 4.35 / 72.81 | 5 | 61 |
8 | 13 | 33.96 | 20 | 15.26 | 396 | 121 | 4.47 / 72.93 | 6 | 53 |
9 | 8 | 0.04 | 240 | 15.21 | 330 | 1205 | 5.67 / 74.14 | 6 | -99 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 16 | 15.24 | 459 | 112 | 0.11 / 62.86 | 6 | 7 |
2 | 10 | 1505.72 | 4 | 14.94 | 2460 | 147 | 0.26 / 63.00 | 5 | 40 |
3 | 7 | 2013.88 | 40 | 14.72 | 3127 | 1841 | 2.10 / 64.84 | 40 | 44 |
4 | 13 | 1983.04 | 20 | 14.72 | 3087 | 909 | 3.01 / 65.75 | 5 | 47 |
5 | 13 | 1451.20 | 20 | 14.82 | 2356 | 698 | 3.71 / 66.45 | 5 | 55 |
6 | 13 | 905.12 | 20 | 14.96 | 1618 | 484 | 4.19 / 66.94 | 5 | 64 |
7 | 13 | 230.12 | 20 | 15.19 | 695 | 211 | 4.40 / 67.15 | 5 | 64 |
8 | 13 | 39.80 | 20 | 15.25 | 408 | 124 | 4.53 / 67.27 | 6 | 54 |
9 | 8 | -0.04 | 238 | 15.21 | 330 | 1195 | 5.72 / 68.47 | 6 | -99 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 16 | 15.23 | 457 | 111 | 0.11 / 57.19 | 6 | 7 |
2 | 10 | 1500.52 | 4 | 14.95 | 2455 | 147 | 0.26 / 57.34 | 5 | 39 |
3 | 7 | 2003.60 | 40 | 14.73 | 3116 | 1836 | 2.09 / 59.18 | 39 | 43 |
4 | 13 | 1972.20 | 20 | 14.73 | 3066 | 903 | 3.00 / 60.08 | 5 | 46 |
5 | 13 | 1536.40 | 20 | 14.80 | 2492 | 738 | 3.73 / 60.82 | 5 | 54 |
6 | 13 | 802.00 | 20 | 14.99 | 1492 | 447 | 4.18 / 61.26 | 5 | 66 |
7 | 13 | 143.32 | 20 | 15.23 | 564 | 172 | 4.35 / 61.44 | 5 | 58 |
8 | 13 | 41.60 | 20 | 15.26 | 402 | 123 | 4.48 / 61.56 | 6 | 52 |
9 | 8 | 0.20 | 238 | 15.22 | 327 | 1185 | 5.66 / 62.74 | 6 | 155 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 16 | 15.24 | 473 | 115 | 0.12 / 51.59 | 6 | 7 |
2 | 10 | 1502.72 | 3 | 14.95 | 2452 | 110 | 0.23 / 51.70 | 5 | 40 |
3 | 7 | 2009.92 | 40 | 14.73 | 3123 | 1840 | 2.07 / 53.54 | 40 | 43 |
4 | 13 | 1978.44 | 20 | 14.73 | 3073 | 905 | 2.97 / 54.45 | 5 | 46 |
5 | 13 | 1429.80 | 20 | 14.83 | 2336 | 693 | 3.66 / 55.14 | 5 | 56 |
6 | 13 | 801.76 | 20 | 15.00 | 1493 | 448 | 4.11 / 55.59 | 5 | 66 |
7 | 13 | 136.48 | 20 | 15.23 | 558 | 170 | 4.28 / 55.76 | 5 | 60 |
8 | 13 | 65.16 | 20 | 15.25 | 447 | 136 | 4.42 / 55.89 | 5 | 57 |
9 | 8 | 0.04 | 238 | 15.22 | 328 | 1188 | 5.61 / 57.08 | 6 | -99 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 16 | 15.24 | 453 | 110 | 0.11 / 46.01 | 6 | 7 |
2 | 10 | 1506.88 | 4 | 14.96 | 2440 | 146 | 0.26 / 46.15 | 5 | 39 |
3 | 7 | 2012.20 | 41 | 14.73 | 3110 | 1878 | 2.13 / 48.03 | 39 | 44 |
4 | 13 | 1980.36 | 20 | 14.73 | 3076 | 906 | 3.04 / 48.94 | 5 | 46 |
5 | 13 | 1340.08 | 20 | 14.86 | 2224 | 661 | 3.70 / 49.60 | 5 | 57 |
6 | 13 | 758.84 | 20 | 15.01 | 1430 | 429 | 4.13 / 50.03 | 5 | 66 |
7 | 13 | 122.92 | 20 | 15.24 | 534 | 163 | 4.29 / 50.19 | 5 | 60 |
8 | 8 | -0.12 | 257 | 15.23 | 329 | 1288 | 5.58 / 51.48 | 6 | -99 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 16 | 15.25 | 444 | 108 | 0.11 / 40.39 | 6 | 6 |
2 | 10 | 1501.64 | 3 | 14.96 | 2461 | 110 | 0.22 / 40.50 | 5 | 39 |
3 | 7 | 2012.28 | 40 | 14.74 | 3121 | 1840 | 2.06 / 42.34 | 39 | 43 |
4 | 13 | 1980.32 | 20 | 14.74 | 3083 | 909 | 2.97 / 43.25 | 5 | 46 |
5 | 13 | 1428.96 | 20 | 14.84 | 2339 | 694 | 3.66 / 43.94 | 5 | 56 |
6 | 13 | 908.24 | 20 | 14.97 | 1623 | 486 | 4.15 / 44.43 | 5 | 63 |
7 | 13 | 123.36 | 20 | 15.24 | 535 | 163 | 4.31 / 44.59 | 5 | 60 |
8 | 13 | 27.00 | 20 | 15.27 | 383 | 117 | 4.43 / 44.71 | 6 | 55 |
9 | 8 | 0.08 | 238 | 15.23 | 327 | 1185 | 5.61 / 45.90 | 6 | -99 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 16 | 15.25 | 451 | 110 | 0.11 / 34.82 | 6 | 6 |
2 | 10 | 1505.56 | 4 | 14.97 | 2446 | 146 | 0.26 / 34.97 | 5 | 39 |
3 | 7 | 2005.40 | 40 | 14.74 | 3098 | 1827 | 2.08 / 36.80 | 39 | 43 |
4 | 13 | 1974.76 | 20 | 14.74 | 3080 | 908 | 2.99 / 37.71 | 5 | 46 |
5 | 13 | 1395.16 | 20 | 14.85 | 2290 | 680 | 3.67 / 38.39 | 5 | 56 |
6 | 13 | 812.36 | 20 | 15.00 | 1512 | 454 | 4.12 / 38.84 | 5 | 65 |
7 | 13 | 108.52 | 20 | 15.25 | 509 | 155 | 4.28 / 38.99 | 5 | 57 |
8 | 13 | 20.08 | 20 | 15.28 | 372 | 114 | 4.39 / 39.11 | 6 | 52 |
9 | 8 | 0.04 | 235 | 15.23 | 328 | 1174 | 5.57 / 40.28 | 6 | 160 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 16 | 15.25 | 459 | 112 | 0.11 / 29.20 | 6 | 6 |
2 | 10 | 1500.08 | 4 | 14.96 | 2457 | 147 | 0.26 / 29.35 | 5 | 39 |
3 | 7 | 2010.96 | 40 | 14.74 | 3116 | 1837 | 2.10 / 31.18 | 39 | 43 |
4 | 13 | 1978.40 | 20 | 14.75 | 3073 | 907 | 3.00 / 32.09 | 5 | 46 |
5 | 13 | 1366.48 | 20 | 14.86 | 2262 | 672 | 3.68 / 32.76 | 5 | 57 |
6 | 13 | 863.80 | 20 | 14.99 | 1575 | 472 | 4.15 / 33.24 | 5 | 65 |
7 | 13 | 146.16 | 20 | 15.24 | 567 | 173 | 4.32 / 33.41 | 5 | 58 |
8 | 13 | 36.84 | 20 | 15.27 | 396 | 121 | 4.44 / 33.53 | 6 | 52 |
9 | 8 | -0.08 | 238 | 15.23 | 327 | 1185 | 5.63 / 34.71 | 6 | 251 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 16 | 15.25 | 455 | 111 | 0.11 / 23.62 | 6 | 6 |
2 | 10 | 1500.60 | 4 | 14.97 | 2446 | 146 | 0.26 / 23.77 | 5 | 39 |
3 | 7 | 2004.64 | 40 | 14.75 | 3105 | 1832 | 2.09 / 25.60 | 39 | 44 |
4 | 13 | 1972.48 | 20 | 14.75 | 3072 | 906 | 3.00 / 26.50 | 5 | 46 |
5 | 13 | 1387.80 | 20 | 14.86 | 2284 | 679 | 3.67 / 27.18 | 5 | 56 |
6 | 13 | 734.68 | 20 | 15.03 | 1402 | 421 | 4.10 / 27.60 | 5 | 66 |
7 | 13 | 173.08 | 20 | 15.23 | 610 | 186 | 4.28 / 27.79 | 5 | 60 |
8 | 13 | 34.32 | 20 | 15.28 | 390 | 119 | 4.40 / 27.91 | 6 | 51 |
9 | 8 | 0.08 | 238 | 15.23 | 325 | 1178 | 5.58 / 29.09 | 6 | -99 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 16 | 15.25 | 470 | 115 | 0.11 / 18.01 | 6 | 7 |
2 | 10 | 1501.72 | 3 | 14.97 | 2474 | 111 | 0.23 / 18.12 | 5 | 40 |
3 | 7 | 2010.00 | 40 | 14.76 | 3098 | 1829 | 2.05 / 19.95 | 40 | 44 |
4 | 13 | 1978.44 | 20 | 14.76 | 3059 | 903 | 2.96 / 20.85 | 5 | 47 |
5 | 13 | 1504.24 | 20 | 14.83 | 2423 | 719 | 3.68 / 21.57 | 5 | 55 |
6 | 13 | 796.44 | 20 | 15.02 | 1477 | 444 | 4.12 / 22.01 | 5 | 66 |
7 | 13 | 196.60 | 20 | 15.22 | 642 | 195 | 4.32 / 22.21 | 5 | 63 |
8 | 13 | 43.16 | 20 | 15.27 | 407 | 124 | 4.44 / 22.33 | 6 | 56 |
9 | 8 | 0.12 | 238 | 15.23 | 325 | 1178 | 5.62 / 23.51 | 6 | 240 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 16 | 15.22 | 468 | 114 | 0.11 / 12.41 | 6 | 6 |
2 | 10 | 1501.84 | 3 | 14.96 | 2430 | 109 | 0.22 / 12.52 | 5 | 41 |
3 | 7 | 2009.32 | 40 | 14.77 | 3109 | 1837 | 2.06 / 14.35 | 41 | 44 |
4 | 13 | 1943.12 | 20 | 14.78 | 3018 | 892 | 2.95 / 15.25 | 5 | 48 |
5 | 13 | 1477.32 | 20 | 14.84 | 2397 | 711 | 3.66 / 15.96 | 5 | 55 |
6 | 13 | 874.36 | 20 | 14.99 | 1591 | 477 | 4.14 / 16.43 | 5 | 65 |
7 | 13 | 90.12 | 20 | 15.26 | 486 | 148 | 4.29 / 16.58 | 5 | 61 |
8 | 13 | 30.76 | 20 | 15.27 | 395 | 121 | 4.41 / 16.70 | 5 | 57 |
9 | 8 | 0.04 | 235 | 15.23 | 332 | 1188 | 5.60 / 17.89 | 6 | 150 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 10 | 2002.20 | 5 | 14.81 | 3107 | 230 | 0.23 / 7.22 | 5 | 27 |
2 | 7 | 2006.00 | 40 | 14.67 | 3098 | 1818 | 2.05 / 9.03 | 27 | 40 |
3 | 13 | 1837.08 | 20 | 14.70 | 2869 | 843 | 2.89 / 9.88 | 5 | 44 |
4 | 13 | 1290.56 | 20 | 14.82 | 2149 | 637 | 3.53 / 10.52 | 5 | 56 |
5 | 13 | 617.64 | 20 | 15.03 | 1233 | 371 | 3.90 / 10.89 | 5 | 66 |
6 | 13 | 52.40 | 20 | 15.24 | 429 | 131 | 4.03 / 11.02 | 5 | 60 |
7 | 13 | 14.52 | 20 | 15.25 | 364 | 111 | 4.14 / 11.13 | 5 | 57 |
8 | 8 | 0.00 | 231 | 15.20 | 332 | 1166 | 5.31 / 12.29 | 6 | -99 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 10 | 2001.36 | 4 | 14.81 | 3158 | 187 | 0.19 / 1.93 | 5 | 28 |
2 | 7 | 2005.12 | 40 | 14.65 | 3098 | 1815 | 2.00 / 3.74 | 28 | 41 |
3 | 13 | 1869.40 | 20 | 14.68 | 2911 | 855 | 2.86 / 4.60 | 5 | 44 |
4 | 13 | 1243.12 | 20 | 14.84 | 2087 | 619 | 3.48 / 5.22 | 5 | 56 |
5 | 13 | 621.08 | 20 | 15.05 | 1231 | 371 | 3.85 / 5.59 | 5 | 67 |
6 | 13 | 53.00 | 20 | 15.26 | 428 | 131 | 3.98 / 5.72 | 5 | 57 |
7 | 8 | 0.08 | 250 | 15.22 | 333 | 1267 | 5.24 / 6.99 | 6 | 136 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 7 | 78.44 | 40 | 15.56 | 410 | 255 | 0.26 / 0.26 | 6 | 23 |
2 | 13 | 99.44 | 20 | 15.54 | 435 | 135 | 0.39 / 0.39 | 6 | 22 |
3 | 13 | 81.56 | 20 | 15.53 | 408 | 127 | 0.52 / 0.52 | 6 | 19 |
4 | 13 | 52.68 | 20 | 15.52 | 368 | 114 | 0.63 / 0.63 | 6 | 26 |
5 | 13 | 14.60 | 20 | 15.51 | 311 | 96 | 0.73 / 0.73 | 6 | 23 |
6 | 8 | -0.00 | 231 | 15.46 | 284 | 1014 | 1.74 / 1.74 | 6 | -99 |
Average= | 1.74 (KJ/cycle) |