SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 30 | 14.87 | 480 | 214 | 0.21 / 1025.81 | 5 | 24 |
2 | 7 | 2010.92 | 40 | 14.43 | 3315 | 1913 | 2.13 / 1027.72 | 24 | 60 |
3 | 13 | 1982.00 | 20 | 14.40 | 3288 | 947 | 3.07 / 1028.67 | 5 | 63 |
4 | 13 | 1474.08 | 20 | 14.42 | 2571 | 741 | 3.82 / 1029.41 | 5 | 76 |
5 | 13 | 805.24 | 20 | 14.60 | 1602 | 468 | 4.28 / 1029.88 | 5 | 85 |
6 | 13 | 79.64 | 20 | 14.89 | 453 | 135 | 4.42 / 1030.01 | 5 | 62 |
7 | 8 | 0.00 | 216 | 14.87 | 313 | 1005 | 5.42 / 1031.02 | 5 | 137 |
Average= | 11.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 30 | 14.88 | 482 | 215 | 0.22 / 1020.26 | 5 | 21 |
2 | 7 | 2008.16 | 40 | 14.44 | 3307 | 1910 | 2.13 / 1022.17 | 21 | 60 |
3 | 13 | 1977.96 | 20 | 14.40 | 3277 | 944 | 3.07 / 1023.11 | 5 | 64 |
4 | 13 | 1496.80 | 20 | 14.42 | 2607 | 752 | 3.82 / 1023.87 | 5 | 74 |
5 | 13 | 940.00 | 20 | 14.54 | 1785 | 519 | 4.34 / 1024.38 | 5 | 81 |
6 | 13 | 157.32 | 20 | 14.86 | 583 | 173 | 4.51 / 1024.56 | 5 | 64 |
7 | 8 | 0.00 | 223 | 14.86 | 313 | 1037 | 5.55 / 1025.60 | 5 | 143 |
Average= | 11.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 30 | 14.88 | 479 | 214 | 0.21 / 1014.85 | 5 | 19 |
2 | 7 | 2010.44 | 40 | 14.44 | 3307 | 1910 | 2.12 / 1016.76 | 19 | 60 |
3 | 13 | 1982.24 | 20 | 14.40 | 3285 | 946 | 3.07 / 1017.71 | 5 | 63 |
4 | 13 | 1407.20 | 20 | 14.44 | 2464 | 712 | 3.78 / 1018.42 | 5 | 75 |
5 | 13 | 787.20 | 20 | 14.60 | 1579 | 461 | 4.24 / 1018.88 | 5 | 84 |
6 | 13 | 73.28 | 20 | 14.89 | 451 | 134 | 4.38 / 1019.02 | 5 | 61 |
7 | 8 | 0.24 | 220 | 14.87 | 314 | 1027 | 5.40 / 1020.04 | 5 | 136 |
Average= | 11.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 30 | 14.89 | 457 | 204 | 0.20 / 1009.49 | 5 | 17 |
2 | 7 | 2013.44 | 40 | 14.42 | 3346 | 1930 | 2.13 / 1011.42 | 17 | 61 |
3 | 13 | 1986.24 | 20 | 14.40 | 3283 | 946 | 3.08 / 1012.36 | 5 | 64 |
4 | 13 | 1258.16 | 20 | 14.48 | 2235 | 647 | 3.73 / 1013.01 | 5 | 77 |
5 | 13 | 862.60 | 20 | 14.57 | 1675 | 488 | 4.21 / 1013.50 | 5 | 84 |
6 | 13 | 75.00 | 20 | 14.89 | 446 | 133 | 4.35 / 1013.63 | 5 | 60 |
7 | 8 | 0.16 | 220 | 14.87 | 309 | 1011 | 5.36 / 1014.64 | 5 | 145 |
Average= | 11.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 30 | 14.90 | 467 | 209 | 0.21 / 1004.10 | 5 | 18 |
2 | 7 | 2008.88 | 40 | 14.43 | 3296 | 1902 | 2.11 / 1006.00 | 18 | 60 |
3 | 13 | 1980.88 | 20 | 14.40 | 3280 | 945 | 3.06 / 1006.95 | 5 | 63 |
4 | 13 | 1364.92 | 20 | 14.45 | 2399 | 693 | 3.75 / 1007.64 | 5 | 76 |
5 | 13 | 856.72 | 20 | 14.57 | 1660 | 484 | 4.23 / 1008.12 | 5 | 84 |
6 | 13 | 96.72 | 20 | 14.89 | 480 | 143 | 4.38 / 1008.27 | 5 | 60 |
7 | 8 | 0.16 | 223 | 14.87 | 306 | 1015 | 5.39 / 1009.28 | 5 | 142 |
Average= | 11.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 30 | 14.89 | 473 | 211 | 0.21 / 998.68 | 5 | 15 |
2 | 7 | 2015.20 | 40 | 14.42 | 3311 | 1910 | 2.12 / 1000.59 | 15 | 59 |
3 | 13 | 1990.00 | 20 | 14.39 | 3293 | 948 | 3.07 / 1001.54 | 5 | 63 |
4 | 13 | 1385.88 | 20 | 14.44 | 2420 | 699 | 3.77 / 1002.24 | 5 | 76 |
5 | 13 | 911.64 | 20 | 14.55 | 1740 | 506 | 4.27 / 1002.74 | 5 | 83 |
6 | 13 | 74.96 | 20 | 14.89 | 449 | 134 | 4.41 / 1002.88 | 5 | 59 |
7 | 8 | 0.12 | 223 | 14.87 | 306 | 1015 | 5.42 / 1003.89 | 5 | 146 |
Average= | 11.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 30 | 14.89 | 446 | 199 | 0.20 / 993.31 | 5 | 15 |
2 | 7 | 2004.40 | 40 | 14.44 | 3307 | 1910 | 2.11 / 995.22 | 15 | 59 |
3 | 13 | 1871.48 | 20 | 14.42 | 3118 | 899 | 3.01 / 996.12 | 5 | 63 |
4 | 13 | 1302.72 | 20 | 14.47 | 2282 | 660 | 3.67 / 996.78 | 5 | 75 |
5 | 13 | 906.68 | 20 | 14.56 | 1727 | 503 | 4.17 / 997.28 | 5 | 82 |
6 | 13 | 119.56 | 20 | 14.87 | 531 | 158 | 4.33 / 997.44 | 5 | 61 |
7 | 8 | 0.12 | 223 | 14.87 | 311 | 1031 | 5.36 / 998.47 | 5 | 145 |
Average= | 12.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 30 | 14.89 | 442 | 197 | 0.20 / 987.85 | 5 | 13 |
2 | 7 | 2011.80 | 40 | 14.42 | 3334 | 1923 | 2.12 / 989.77 | 13 | 59 |
3 | 13 | 1979.36 | 20 | 14.39 | 3283 | 945 | 3.07 / 990.71 | 5 | 63 |
4 | 13 | 1414.16 | 20 | 14.43 | 2499 | 721 | 3.79 / 991.44 | 5 | 75 |
5 | 13 | 926.84 | 20 | 14.55 | 1745 | 508 | 4.29 / 991.94 | 5 | 83 |
6 | 13 | 106.12 | 20 | 14.88 | 494 | 147 | 4.44 / 992.09 | 5 | 60 |
7 | 13 | 14.60 | 20 | 14.91 | 336 | 100 | 4.54 / 992.19 | 5 | 60 |
8 | 8 | 0.00 | 201 | 14.87 | 307 | 918 | 5.46 / 993.11 | 5 | 143 |
Average= | 12.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 30 | 14.91 | 465 | 208 | 0.21 / 982.38 | 6 | 13 |
2 | 7 | 2011.48 | 40 | 14.43 | 3325 | 1919 | 2.13 / 984.30 | 13 | 60 |
3 | 13 | 1980.08 | 20 | 14.40 | 3279 | 944 | 3.07 / 985.24 | 5 | 64 |
4 | 13 | 1512.32 | 20 | 14.41 | 2621 | 755 | 3.83 / 986.00 | 5 | 73 |
5 | 13 | 868.96 | 20 | 14.57 | 1702 | 496 | 4.32 / 986.49 | 5 | 85 |
6 | 13 | 107.12 | 20 | 14.89 | 494 | 147 | 4.47 / 986.64 | 5 | 60 |
7 | 13 | 20.00 | 20 | 14.91 | 345 | 103 | 4.57 / 986.74 | 5 | 58 |
8 | 8 | 0.08 | 201 | 14.87 | 303 | 906 | 5.48 / 987.65 | 5 | 135 |
Average= | 12.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 30 | 14.90 | 470 | 210 | 0.21 / 976.96 | 5 | 14 |
2 | 7 | 2010.92 | 40 | 14.42 | 3304 | 1906 | 2.12 / 978.86 | 14 | 60 |
3 | 13 | 1981.96 | 20 | 14.39 | 3287 | 946 | 3.06 / 979.81 | 5 | 64 |
4 | 13 | 1341.64 | 20 | 14.45 | 2387 | 690 | 3.75 / 980.50 | 5 | 78 |
5 | 13 | 917.56 | 20 | 14.55 | 1757 | 511 | 4.26 / 981.01 | 5 | 84 |
6 | 13 | 105.64 | 20 | 14.88 | 500 | 149 | 4.41 / 981.16 | 5 | 61 |
7 | 13 | 20.40 | 20 | 14.91 | 348 | 104 | 4.52 / 981.26 | 5 | 59 |
8 | 8 | 0.12 | 201 | 14.87 | 304 | 909 | 5.42 / 982.17 | 5 | 138 |
Average= | 12.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 30 | 14.90 | 461 | 206 | 0.21 / 971.59 | 5 | 14 |
2 | 7 | 2012.08 | 40 | 14.42 | 3311 | 1910 | 2.12 / 973.50 | 14 | 61 |
3 | 13 | 1878.16 | 20 | 14.41 | 3148 | 907 | 3.02 / 974.41 | 5 | 66 |
4 | 13 | 1362.60 | 20 | 14.45 | 2393 | 692 | 3.71 / 975.10 | 5 | 77 |
5 | 13 | 811.96 | 20 | 14.60 | 1614 | 471 | 4.19 / 975.57 | 5 | 86 |
6 | 13 | 86.84 | 20 | 14.89 | 474 | 141 | 4.33 / 975.72 | 5 | 60 |
7 | 13 | 10.88 | 20 | 14.91 | 342 | 102 | 4.43 / 975.82 | 5 | 59 |
8 | 8 | 0.04 | 197 | 14.87 | 312 | 914 | 5.34 / 976.73 | 5 | 133 |
9 | 14 | -0.12 | 3 | 14.84 | 317 | 14 | 5.36 / 976.75 | 49 | 98 |
Average= | 12.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 30 | 14.87 | 470 | 210 | 0.21 / 966.04 | 5 | 16 |
2 | 7 | 2012.28 | 40 | 14.43 | 3326 | 1920 | 2.13 / 967.96 | 16 | 61 |
3 | 13 | 1981.76 | 20 | 14.40 | 3282 | 945 | 3.07 / 968.90 | 5 | 63 |
4 | 13 | 1486.96 | 20 | 14.42 | 2595 | 748 | 3.82 / 969.65 | 5 | 75 |
5 | 13 | 1054.04 | 20 | 14.50 | 1948 | 565 | 4.39 / 970.22 | 5 | 82 |
6 | 13 | 50.48 | 20 | 14.91 | 411 | 123 | 4.51 / 970.34 | 5 | 60 |
7 | 13 | 13.12 | 20 | 14.92 | 350 | 104 | 4.61 / 970.44 | 5 | 60 |
8 | 8 | 0.04 | 203 | 14.87 | 313 | 945 | 5.56 / 971.39 | 5 | 147 |
Average= | 12.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 31 | 14.90 | 462 | 213 | 0.21 / 960.36 | 5 | 18 |
2 | 7 | 2011.00 | 41 | 14.43 | 3314 | 1961 | 2.17 / 962.32 | 18 | 60 |
3 | 13 | 1978.60 | 20 | 14.39 | 3285 | 945 | 3.12 / 963.26 | 5 | 64 |
4 | 13 | 1260.68 | 20 | 14.48 | 2255 | 653 | 3.77 / 963.92 | 5 | 78 |
5 | 13 | 961.36 | 20 | 14.54 | 1799 | 523 | 4.30 / 964.44 | 5 | 82 |
6 | 13 | 507.72 | 20 | 14.70 | 1138 | 335 | 4.63 / 964.78 | 5 | 76 |
7 | 13 | 30.56 | 20 | 14.88 | 382 | 114 | 4.74 / 964.89 | 5 | 63 |
8 | 8 | 0.08 | 203 | 14.84 | 312 | 940 | 5.68 / 965.83 | 5 | 141 |
Average= | 12.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 31 | 14.90 | 480 | 222 | 0.22 / 955.05 | 5 | 19 |
2 | 7 | 2007.04 | 40 | 14.43 | 3304 | 1907 | 2.13 / 956.95 | 19 | 60 |
3 | 13 | 1908.32 | 20 | 14.41 | 3186 | 918 | 3.05 / 957.87 | 5 | 64 |
4 | 13 | 1241.96 | 20 | 14.49 | 2228 | 646 | 3.69 / 958.52 | 5 | 78 |
5 | 13 | 848.12 | 20 | 14.58 | 1673 | 488 | 4.18 / 959.01 | 5 | 83 |
6 | 13 | 93.60 | 20 | 14.89 | 473 | 141 | 4.32 / 959.15 | 5 | 60 |
7 | 8 | 0.04 | 218 | 14.87 | 308 | 998 | 5.32 / 960.15 | 5 | 134 |
Average= | 12.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 31 | 14.91 | 467 | 216 | 0.22 / 949.59 | 5 | 23 |
2 | 7 | 2005.88 | 40 | 14.44 | 3320 | 1918 | 2.13 / 951.51 | 23 | 59 |
3 | 13 | 1976.56 | 20 | 14.41 | 3260 | 940 | 3.07 / 952.45 | 5 | 63 |
4 | 13 | 1423.64 | 20 | 14.45 | 2475 | 715 | 3.79 / 953.17 | 5 | 74 |
5 | 13 | 793.92 | 20 | 14.62 | 1583 | 463 | 4.25 / 953.63 | 5 | 83 |
6 | 13 | 112.44 | 20 | 14.90 | 516 | 154 | 4.40 / 953.78 | 5 | 59 |
7 | 8 | 0.20 | 223 | 14.88 | 314 | 1042 | 5.45 / 954.83 | 5 | 147 |
Average= | 12.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 31 | 14.90 | 478 | 221 | 0.22 / 943.99 | 5 | 24 |
2 | 7 | 2008.36 | 40 | 14.44 | 3295 | 1903 | 2.12 / 945.89 | 24 | 60 |
3 | 13 | 1975.68 | 20 | 14.41 | 3278 | 945 | 3.07 / 946.84 | 5 | 64 |
4 | 13 | 1709.72 | 20 | 14.39 | 2888 | 831 | 3.90 / 947.67 | 5 | 70 |
5 | 13 | 1062.16 | 20 | 14.52 | 1926 | 559 | 4.46 / 948.23 | 5 | 80 |
6 | 13 | 91.80 | 20 | 14.91 | 456 | 136 | 4.60 / 948.37 | 5 | 59 |
7 | 8 | 0.08 | 223 | 14.90 | 305 | 1013 | 5.61 / 949.38 | 5 | 139 |
Average= | 12.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 30 | 14.90 | 500 | 223 | 0.22 / 938.51 | 5 | 29 |
2 | 7 | 2003.96 | 40 | 14.44 | 3304 | 1908 | 2.13 / 940.42 | 7 | 60 |
3 | 13 | 1977.32 | 20 | 14.41 | 3280 | 945 | 3.08 / 941.36 | 5 | 64 |
4 | 13 | 1448.32 | 20 | 14.44 | 2531 | 731 | 3.81 / 942.10 | 5 | 75 |
5 | 13 | 924.52 | 20 | 14.56 | 1743 | 508 | 4.32 / 942.60 | 5 | 82 |
6 | 13 | 50.00 | 20 | 14.92 | 409 | 122 | 4.44 / 942.73 | 5 | 60 |
7 | 8 | 0.08 | 220 | 14.89 | 319 | 1045 | 5.48 / 943.77 | 5 | 135 |
Average= | 12.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 30 | 14.90 | 503 | 225 | 0.22 / 932.94 | 5 | 29 |
2 | 7 | 2004.32 | 40 | 14.44 | 3315 | 1915 | 2.14 / 934.85 | 29 | 61 |
3 | 13 | 1973.64 | 20 | 14.42 | 3289 | 949 | 3.09 / 935.80 | 5 | 65 |
4 | 13 | 1572.60 | 20 | 14.42 | 2713 | 782 | 3.87 / 936.59 | 5 | 73 |
5 | 13 | 901.68 | 20 | 14.57 | 1719 | 501 | 4.37 / 937.09 | 5 | 83 |
6 | 13 | 46.92 | 20 | 14.93 | 425 | 127 | 4.50 / 937.21 | 5 | 59 |
7 | 8 | 0.08 | 220 | 14.89 | 328 | 1074 | 5.57 / 938.29 | 5 | 135 |
Average= | 13.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 30 | 14.91 | 488 | 218 | 0.22 / 927.46 | 5 | 29 |
2 | 7 | 2014.40 | 40 | 14.46 | 3311 | 1915 | 2.13 / 929.38 | 29 | 61 |
3 | 13 | 1986.44 | 20 | 14.42 | 3278 | 945 | 3.08 / 930.32 | 5 | 65 |
4 | 13 | 1266.60 | 20 | 14.51 | 2269 | 658 | 3.74 / 930.98 | 5 | 78 |
5 | 13 | 963.92 | 20 | 14.56 | 1823 | 531 | 4.27 / 931.51 | 5 | 83 |
6 | 13 | 53.16 | 20 | 14.93 | 429 | 128 | 4.40 / 931.64 | 5 | 61 |
7 | 8 | 0.16 | 220 | 14.89 | 328 | 1074 | 5.47 / 932.71 | 5 | 139 |
Average= | 13.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 30 | 14.88 | 496 | 221 | 0.22 / 922.01 | 5 | 37 |
2 | 7 | 2013.48 | 40 | 14.45 | 3316 | 1917 | 2.14 / 923.93 | 37 | 63 |
3 | 13 | 1983.40 | 20 | 14.42 | 3314 | 956 | 3.09 / 924.89 | 5 | 67 |
4 | 13 | 1340.04 | 20 | 14.49 | 2387 | 692 | 3.79 / 925.58 | 5 | 79 |
5 | 13 | 791.32 | 20 | 14.63 | 1573 | 460 | 4.25 / 926.04 | 5 | 86 |
6 | 13 | 51.24 | 20 | 14.94 | 427 | 128 | 4.37 / 926.17 | 5 | 68 |
7 | 8 | 0.24 | 220 | 14.90 | 329 | 1078 | 5.45 / 927.24 | 5 | 137 |
Average= | 13.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 32 | 14.89 | 494 | 235 | 0.24 / 916.50 | 5 | 40 |
2 | 3 | 923.04 | -1 | 15.30 | 0 | 0 | 0.00 / 916.50 | 5 | 40 |
3 | 7 | 2003.36 | 41 | 14.47 | 3305 | 1961 | 2.20 / 918.46 | 40 | 64 |
4 | 13 | 1972.88 | 20 | 14.44 | 3265 | 943 | 3.14 / 919.41 | 5 | 67 |
5 | 13 | 1270.60 | 20 | 14.52 | 2275 | 661 | 3.80 / 920.07 | 5 | 81 |
6 | 13 | 821.12 | 20 | 14.62 | 1603 | 469 | 4.27 / 920.53 | 5 | 87 |
7 | 13 | 98.48 | 20 | 14.91 | 519 | 155 | 4.42 / 920.69 | 5 | 82 |
8 | 8 | -0.12 | 216 | 14.88 | 343 | 1102 | 5.53 / 921.79 | 5 | 138 |
Average= | 13.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 30 | 14.82 | 531 | 236 | 0.24 / 910.90 | 5 | 68 |
2 | 3 | 1063.76 | 2 | 14.82 | 2011 | 60 | 0.30 / 910.96 | 5 | 68 |
3 | 7 | 2015.16 | 41 | 14.45 | 3325 | 1970 | 2.27 / 912.93 | 68 | 65 |
4 | 13 | 1985.88 | 20 | 14.43 | 3285 | 948 | 3.21 / 913.88 | 5 | 69 |
5 | 13 | 1425.92 | 20 | 14.47 | 2506 | 725 | 3.94 / 914.61 | 5 | 81 |
6 | 13 | 676.92 | 20 | 14.68 | 1375 | 404 | 4.34 / 915.01 | 5 | 88 |
7 | 13 | 37.48 | 20 | 14.93 | 421 | 126 | 4.47 / 915.14 | 5 | 86 |
8 | 13 | 16.16 | 20 | 14.94 | 382 | 114 | 4.58 / 915.25 | 5 | 84 |
9 | 8 | 0.00 | 197 | 14.89 | 341 | 1000 | 5.58 / 916.25 | 5 | 138 |
10 | 14 | -0.08 | 3 | 14.86 | 344 | 15 | 5.60 / 916.27 | 37 | 102 |
Average= | 13.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 29 | 14.86 | 523 | 225 | 0.23 / 905.09 | 5 | 42 |
2 | 3 | 1047.88 | 1 | 14.87 | 2032 | 30 | 0.26 / 905.12 | 5 | 61 |
3 | 7 | 2008.68 | 41 | 14.44 | 3326 | 1969 | 2.22 / 907.09 | 61 | 66 |
4 | 13 | 1979.48 | 20 | 14.42 | 3277 | 945 | 3.17 / 908.03 | 5 | 69 |
5 | 13 | 1374.52 | 20 | 14.48 | 2438 | 706 | 3.88 / 908.74 | 5 | 82 |
6 | 13 | 695.12 | 20 | 14.66 | 1425 | 418 | 4.29 / 909.16 | 5 | 89 |
7 | 13 | 131.08 | 20 | 14.88 | 584 | 174 | 4.47 / 909.33 | 5 | 91 |
8 | 8 | 0.32 | 248 | 14.85 | 363 | 1337 | 5.80 / 910.67 | 5 | 133 |
Average= | 13.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 35 | 14.85 | 525 | 273 | 0.27 / 899.37 | 5 | 45 |
2 | 3 | 783.96 | -3 | 15.29 | 0 | 0 | 0.00 / 899.37 | 5 | 45 |
3 | 7 | 2007.24 | 40 | 14.46 | 3320 | 1920 | 2.19 / 901.29 | 45 | 64 |
4 | 13 | 1977.64 | 20 | 14.43 | 3273 | 945 | 3.14 / 902.24 | 5 | 68 |
5 | 13 | 1276.40 | 20 | 14.52 | 2275 | 661 | 3.80 / 902.90 | 5 | 81 |
6 | 13 | 874.88 | 20 | 14.60 | 1688 | 493 | 4.29 / 903.39 | 5 | 90 |
7 | 13 | 335.16 | 20 | 14.79 | 892 | 264 | 4.56 / 903.65 | 5 | 93 |
8 | 8 | -0.04 | 234 | 14.86 | 348 | 1210 | 5.77 / 904.86 | 5 | 135 |
Average= | 13.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 35 | 14.78 | 562 | 291 | 0.29 / 893.53 | 5 | 80 |
2 | 7 | 2010.60 | 41 | 14.48 | 3306 | 1963 | 2.25 / 895.49 | 80 | 64 |
3 | 13 | 1873.68 | 20 | 14.47 | 3137 | 908 | 3.16 / 896.40 | 5 | 70 |
4 | 13 | 1402.76 | 20 | 14.50 | 2473 | 717 | 3.88 / 897.12 | 5 | 79 |
5 | 13 | 672.88 | 20 | 14.70 | 1376 | 405 | 4.28 / 897.52 | 5 | 88 |
6 | 13 | 286.96 | 20 | 14.82 | 824 | 244 | 4.53 / 897.77 | 5 | 91 |
7 | 8 | 0.20 | 249 | 14.87 | 360 | 1333 | 5.86 / 899.10 | 5 | 139 |
Average= | 13.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 35 | 14.78 | 547 | 283 | 0.28 / 887.49 | 5 | 79 |
2 | 7 | 2008.12 | 40 | 14.48 | 3314 | 1919 | 2.20 / 889.41 | 79 | 65 |
3 | 13 | 1980.40 | 20 | 14.46 | 3257 | 942 | 3.14 / 890.35 | 5 | 68 |
4 | 13 | 1355.88 | 20 | 14.51 | 2404 | 698 | 3.84 / 891.05 | 5 | 81 |
5 | 13 | 584.20 | 20 | 14.72 | 1257 | 370 | 4.21 / 891.42 | 5 | 91 |
6 | 13 | 80.76 | 20 | 14.90 | 526 | 157 | 4.37 / 891.57 | 5 | 89 |
7 | 8 | 0.16 | 294 | 14.84 | 382 | 1667 | 6.04 / 893.24 | 5 | 136 |
Average= | 13.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 33 | 14.77 | 555 | 271 | 0.27 / 881.29 | 5 | 81 |
2 | 10 | 1001.32 | 3 | 14.73 | 1909 | 84 | 0.35 / 881.37 | 5 | 77 |
3 | 7 | 2009.08 | 40 | 14.47 | 3316 | 1919 | 2.27 / 883.29 | 77 | 66 |
4 | 13 | 1980.60 | 20 | 14.43 | 3294 | 951 | 3.22 / 884.24 | 5 | 69 |
5 | 13 | 1393.28 | 20 | 14.49 | 2473 | 717 | 3.94 / 884.96 | 5 | 82 |
6 | 13 | 686.76 | 20 | 14.68 | 1426 | 419 | 4.36 / 885.38 | 5 | 92 |
7 | 13 | 151.08 | 20 | 14.87 | 627 | 186 | 4.55 / 885.56 | 5 | 90 |
8 | 8 | -0.20 | 289 | 14.83 | 383 | 1641 | 6.19 / 887.20 | 5 | 133 |
Average= | 14.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 32 | 14.81 | 539 | 255 | 0.26 / 875.08 | 5 | 71 |
2 | 10 | 1003.40 | 3 | 14.79 | 1934 | 86 | 0.34 / 875.16 | 5 | 74 |
3 | 3 | 950.32 | -1 | 15.27 | 0 | 0 | 0.09 / 875.16 | 5 | 74 |
4 | 7 | 2013.04 | 40 | 14.47 | 3333 | 1929 | 2.27 / 877.09 | 74 | 65 |
5 | 13 | 1985.04 | 20 | 14.44 | 3273 | 945 | 3.22 / 878.04 | 5 | 68 |
6 | 13 | 1390.60 | 20 | 14.50 | 2471 | 717 | 3.93 / 878.75 | 5 | 81 |
7 | 13 | 667.56 | 20 | 14.69 | 1387 | 408 | 4.34 / 879.16 | 5 | 90 |
8 | 13 | 137.72 | 20 | 14.87 | 613 | 182 | 4.52 / 879.34 | 5 | 88 |
9 | 8 | 0.44 | 289 | 14.82 | 390 | 1670 | 6.19 / 881.01 | 5 | 132 |
Average= | 14.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 34 | 14.83 | 526 | 265 | 0.27 / 869.10 | 5 | 70 |
2 | 3 | 929.16 | -1 | 15.27 | 0 | 0 | 0.00 / 869.10 | 5 | 70 |
3 | 7 | 2012.80 | 40 | 14.47 | 3325 | 1925 | 2.19 / 871.02 | 70 | 65 |
4 | 13 | 1985.68 | 20 | 14.45 | 3273 | 946 | 3.14 / 871.97 | 5 | 68 |
5 | 13 | 1414.80 | 20 | 14.50 | 2478 | 719 | 3.85 / 872.68 | 5 | 81 |
6 | 13 | 660.44 | 20 | 14.71 | 1348 | 397 | 4.25 / 873.08 | 5 | 89 |
7 | 13 | 274.00 | 20 | 14.83 | 804 | 238 | 4.49 / 873.32 | 5 | 92 |
8 | 8 | 0.08 | 272 | 14.85 | 372 | 1503 | 5.99 / 874.82 | 5 | 129 |
Average= | 14.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 33 | 14.78 | 537 | 262 | 0.26 / 863.02 | 5 | 78 |
2 | 10 | 1048.92 | 3 | 14.77 | 1962 | 87 | 0.35 / 863.11 | 5 | 73 |
3 | 3 | 958.56 | -1 | 15.26 | 0 | 0 | 0.09 / 863.11 | 5 | 73 |
4 | 7 | 2012.84 | 40 | 14.47 | 3306 | 1914 | 2.26 / 865.02 | 73 | 66 |
5 | 13 | 1981.88 | 20 | 14.45 | 3269 | 945 | 3.21 / 865.97 | 5 | 70 |
6 | 13 | 1559.76 | 20 | 14.47 | 2679 | 775 | 3.98 / 866.74 | 5 | 80 |
7 | 13 | 769.88 | 20 | 14.67 | 1511 | 443 | 4.43 / 867.19 | 5 | 91 |
8 | 13 | 169.16 | 20 | 14.87 | 637 | 189 | 4.62 / 867.38 | 5 | 91 |
9 | 13 | 34.60 | 20 | 14.91 | 445 | 133 | 4.75 / 867.51 | 5 | 89 |
10 | 13 | 11.80 | 20 | 14.91 | 407 | 121 | 4.87 / 867.63 | 5 | 90 |
11 | 8 | 0.16 | 220 | 14.85 | 367 | 1199 | 6.07 / 868.83 | 5 | 129 |
Average= | 14.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 31 | 14.81 | 544 | 250 | 0.25 / 856.72 | 5 | 72 |
2 | 3 | 1070.08 | 2 | 14.81 | 2046 | 61 | 0.31 / 856.78 | 5 | 67 |
3 | 7 | 2008.68 | 40 | 14.47 | 3308 | 1915 | 2.23 / 858.69 | 67 | 67 |
4 | 13 | 1978.08 | 20 | 14.45 | 3272 | 946 | 3.17 / 859.64 | 5 | 70 |
5 | 13 | 1438.56 | 20 | 14.50 | 2514 | 729 | 3.90 / 860.37 | 5 | 82 |
6 | 13 | 842.72 | 20 | 14.64 | 1642 | 481 | 4.38 / 860.85 | 5 | 91 |
7 | 13 | 304.08 | 20 | 14.81 | 845 | 250 | 4.63 / 861.10 | 5 | 95 |
8 | 8 | 0.24 | 293 | 14.83 | 383 | 1664 | 6.29 / 862.76 | 5 | 129 |
Average= | 14.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 30 | 14.83 | 537 | 239 | 0.24 / 850.62 | 5 | 67 |
2 | 3 | 1065.68 | 2 | 14.84 | 2030 | 60 | 0.30 / 850.68 | 5 | 66 |
3 | 7 | 2012.80 | 40 | 14.46 | 3304 | 1911 | 2.21 / 852.59 | 66 | 66 |
4 | 13 | 1982.28 | 20 | 14.44 | 3267 | 944 | 3.15 / 853.54 | 5 | 70 |
5 | 13 | 1375.36 | 20 | 14.50 | 2424 | 703 | 3.86 / 854.24 | 5 | 83 |
6 | 13 | 840.16 | 20 | 14.62 | 1632 | 477 | 4.33 / 854.72 | 5 | 92 |
7 | 13 | 147.88 | 20 | 14.86 | 620 | 184 | 4.52 / 854.90 | 5 | 90 |
8 | 13 | 17.88 | 20 | 14.90 | 428 | 128 | 4.65 / 855.03 | 5 | 90 |
9 | 8 | 0.16 | 261 | 14.83 | 372 | 1440 | 6.09 / 856.47 | 5 | 133 |
Average= | 14.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 30 | 14.86 | 517 | 230 | 0.23 / 844.77 | 5 | 47 |
2 | 7 | 2011.44 | 41 | 14.46 | 3294 | 1953 | 2.18 / 846.72 | 16 | 66 |
3 | 13 | 1982.04 | 20 | 14.44 | 3276 | 946 | 3.13 / 847.67 | 5 | 70 |
4 | 13 | 1447.20 | 20 | 14.48 | 2537 | 735 | 3.86 / 848.40 | 5 | 81 |
5 | 13 | 814.36 | 20 | 14.64 | 1605 | 470 | 4.33 / 848.87 | 5 | 91 |
6 | 13 | 91.32 | 20 | 14.90 | 521 | 155 | 4.49 / 849.03 | 5 | 91 |
7 | 8 | 0.40 | 250 | 14.86 | 364 | 1352 | 5.84 / 850.38 | 5 | 130 |
Average= | 14.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 33 | 14.85 | 529 | 259 | 0.26 / 839.03 | 5 | 51 |
2 | 3 | 893.76 | -2 | 15.28 | 0 | 0 | 0.00 / 839.03 | 5 | 51 |
3 | 7 | 2012.12 | 40 | 14.46 | 3316 | 1918 | 2.18 / 840.95 | 51 | 65 |
4 | 13 | 1983.40 | 20 | 14.43 | 3286 | 948 | 3.13 / 841.90 | 5 | 68 |
5 | 13 | 1495.56 | 20 | 14.47 | 2604 | 754 | 3.88 / 842.65 | 5 | 79 |
6 | 13 | 739.92 | 20 | 14.67 | 1476 | 433 | 4.31 / 843.09 | 5 | 87 |
7 | 13 | 177.80 | 20 | 14.86 | 646 | 192 | 4.50 / 843.28 | 5 | 91 |
8 | 8 | -0.04 | 242 | 14.87 | 351 | 1263 | 5.77 / 844.54 | 5 | 129 |
Average= | 15.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 30 | 14.79 | 538 | 239 | 0.24 / 833.10 | 5 | 67 |
2 | 10 | 1005.52 | 3 | 14.76 | 1911 | 85 | 0.32 / 833.18 | 5 | 75 |
3 | 3 | 1018.52 | 1 | 14.91 | 1988 | 30 | 0.35 / 833.21 | 5 | 20 |
4 | 7 | 2003.56 | 40 | 14.48 | 3288 | 1904 | 2.26 / 835.12 | 20 | 65 |
5 | 13 | 1975.68 | 20 | 14.45 | 3261 | 942 | 3.20 / 836.06 | 5 | 69 |
6 | 13 | 1479.00 | 20 | 14.48 | 2594 | 751 | 3.95 / 836.81 | 5 | 80 |
7 | 13 | 834.68 | 20 | 14.64 | 1633 | 478 | 4.43 / 837.29 | 5 | 89 |
8 | 13 | 192.80 | 20 | 14.86 | 685 | 204 | 4.63 / 837.49 | 5 | 89 |
9 | 8 | -0.20 | 242 | 14.87 | 356 | 1281 | 5.91 / 838.77 | 5 | 144 |
Average= | 15.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 29 | 14.85 | 495 | 213 | 0.21 / 827.13 | 5 | 41 |
2 | 3 | 1028.20 | 1 | 14.90 | 2008 | 30 | 0.24 / 827.16 | 5 | 38 |
3 | 7 | 2005.84 | 40 | 14.46 | 3317 | 1919 | 2.16 / 829.08 | 38 | 66 |
4 | 13 | 1979.16 | 20 | 14.43 | 3294 | 951 | 3.11 / 830.03 | 5 | 70 |
5 | 13 | 1415.80 | 20 | 14.49 | 2485 | 720 | 3.83 / 830.75 | 5 | 81 |
6 | 13 | 499.36 | 20 | 14.75 | 1129 | 333 | 4.17 / 831.08 | 5 | 91 |
7 | 13 | 168.16 | 20 | 14.85 | 645 | 192 | 4.36 / 831.27 | 5 | 91 |
8 | 8 | 0.12 | 287 | 14.83 | 373 | 1588 | 5.94 / 832.86 | 5 | 140 |
Average= | 15.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 29 | 14.90 | 490 | 212 | 0.21 / 821.56 | 5 | 32 |
2 | 7 | 2004.64 | 41 | 14.46 | 3299 | 1956 | 2.17 / 823.52 | 32 | 65 |
3 | 13 | 1975.72 | 20 | 14.43 | 3277 | 946 | 3.11 / 824.46 | 5 | 68 |
4 | 13 | 1293.80 | 20 | 14.51 | 2316 | 672 | 3.79 / 825.13 | 5 | 82 |
5 | 13 | 669.40 | 20 | 14.68 | 1382 | 406 | 4.19 / 825.54 | 5 | 89 |
6 | 13 | 97.76 | 20 | 14.88 | 528 | 157 | 4.35 / 825.70 | 5 | 89 |
7 | 8 | 0.00 | 235 | 14.86 | 349 | 1219 | 5.57 / 826.91 | 5 | 133 |
Average= | 15.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 29 | 14.89 | 483 | 209 | 0.21 / 816.12 | 5 | 28 |
2 | 7 | 2006.92 | 40 | 14.45 | 3317 | 1917 | 2.13 / 818.03 | 28 | 64 |
3 | 13 | 1975.20 | 20 | 14.43 | 3274 | 945 | 3.07 / 818.98 | 5 | 67 |
4 | 13 | 1444.12 | 20 | 14.47 | 2523 | 730 | 3.80 / 819.71 | 5 | 80 |
5 | 13 | 661.52 | 20 | 14.69 | 1353 | 398 | 4.20 / 820.11 | 5 | 88 |
6 | 13 | 63.16 | 20 | 14.92 | 451 | 135 | 4.33 / 820.24 | 5 | 80 |
7 | 8 | 0.16 | 221 | 14.89 | 336 | 1106 | 5.44 / 821.35 | 5 | 139 |
Average= | 15.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 29 | 14.91 | 477 | 206 | 0.21 / 810.58 | 5 | 24 |
2 | 7 | 2003.64 | 40 | 14.46 | 3297 | 1907 | 2.11 / 812.49 | 24 | 64 |
3 | 13 | 1971.12 | 20 | 14.43 | 3272 | 944 | 3.06 / 813.43 | 5 | 68 |
4 | 13 | 1459.48 | 20 | 14.47 | 2557 | 740 | 3.80 / 814.17 | 5 | 80 |
5 | 13 | 719.92 | 20 | 14.66 | 1445 | 424 | 4.22 / 814.60 | 5 | 88 |
6 | 13 | 221.84 | 20 | 14.85 | 714 | 212 | 4.43 / 814.81 | 5 | 88 |
7 | 8 | 0.20 | 223 | 14.88 | 332 | 1102 | 5.53 / 815.91 | 5 | 141 |
Average= | 16.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 29 | 14.91 | 476 | 206 | 0.21 / 805.16 | 5 | 25 |
2 | 7 | 2004.96 | 40 | 14.47 | 3305 | 1913 | 2.12 / 807.07 | 25 | 64 |
3 | 13 | 1834.92 | 20 | 14.47 | 3085 | 893 | 3.01 / 807.97 | 5 | 70 |
4 | 13 | 1358.80 | 20 | 14.50 | 2421 | 702 | 3.71 / 808.67 | 5 | 80 |
5 | 13 | 772.28 | 20 | 14.66 | 1518 | 445 | 4.16 / 809.11 | 5 | 87 |
6 | 13 | 158.08 | 20 | 14.90 | 609 | 181 | 4.34 / 809.29 | 5 | 79 |
7 | 8 | 0.04 | 221 | 14.90 | 328 | 1080 | 5.42 / 810.37 | 5 | 149 |
Average= | 16.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 29 | 14.85 | 503 | 217 | 0.22 / 799.65 | 5 | 38 |
2 | 7 | 2012.00 | 40 | 14.47 | 3305 | 1913 | 2.13 / 801.57 | 38 | 65 |
3 | 13 | 1982.80 | 20 | 14.45 | 3277 | 947 | 3.08 / 802.51 | 5 | 68 |
4 | 13 | 1422.40 | 20 | 14.49 | 2497 | 724 | 3.80 / 803.24 | 5 | 81 |
5 | 13 | 672.60 | 20 | 14.70 | 1367 | 402 | 4.20 / 803.64 | 5 | 90 |
6 | 13 | 252.36 | 20 | 14.84 | 770 | 229 | 4.43 / 803.87 | 5 | 89 |
7 | 8 | 0.00 | 220 | 14.90 | 331 | 1085 | 5.52 / 804.95 | 5 | 133 |
Average= | 16.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 29 | 14.87 | 496 | 214 | 0.21 / 793.87 | 5 | 32 |
2 | 7 | 2009.40 | 40 | 14.48 | 3294 | 1908 | 2.12 / 795.78 | 32 | 65 |
3 | 13 | 1979.76 | 20 | 14.45 | 3279 | 948 | 3.07 / 796.73 | 5 | 69 |
4 | 13 | 1523.56 | 20 | 14.47 | 2633 | 762 | 3.83 / 797.49 | 5 | 79 |
5 | 13 | 811.20 | 20 | 14.64 | 1586 | 464 | 4.30 / 797.95 | 5 | 89 |
6 | 13 | 191.68 | 20 | 14.86 | 672 | 200 | 4.50 / 798.15 | 5 | 87 |
7 | 13 | 41.36 | 20 | 14.90 | 446 | 133 | 4.63 / 798.29 | 5 | 90 |
8 | 8 | -0.04 | 220 | 14.86 | 352 | 1151 | 5.78 / 799.44 | 5 | 133 |
Average= | 16.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 29 | 14.88 | 477 | 206 | 0.21 / 788.21 | 5 | 23 |
2 | 7 | 2012.36 | 40 | 14.47 | 3295 | 1907 | 2.11 / 790.12 | 23 | 64 |
3 | 13 | 1980.52 | 20 | 14.44 | 3266 | 943 | 3.06 / 791.06 | 5 | 68 |
4 | 13 | 1423.32 | 20 | 14.49 | 2490 | 722 | 3.78 / 791.79 | 5 | 80 |
5 | 13 | 631.64 | 20 | 14.70 | 1332 | 392 | 4.17 / 792.18 | 5 | 90 |
6 | 13 | 320.20 | 20 | 14.79 | 868 | 257 | 4.43 / 792.43 | 5 | 91 |
7 | 13 | 16.60 | 20 | 14.91 | 397 | 118 | 4.54 / 792.55 | 5 | 92 |
8 | 8 | -0.32 | 214 | 14.85 | 348 | 1106 | 5.65 / 793.66 | 5 | 129 |
Average= | 16.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 30 | 14.85 | 469 | 209 | 0.21 / 782.70 | 5 | 22 |
2 | 7 | 2003.36 | 40 | 14.48 | 3301 | 1912 | 2.12 / 784.61 | 22 | 64 |
3 | 13 | 1870.64 | 20 | 14.47 | 3109 | 900 | 3.02 / 785.51 | 5 | 70 |
4 | 13 | 1262.68 | 20 | 14.54 | 2245 | 653 | 3.67 / 786.16 | 5 | 80 |
5 | 13 | 822.68 | 20 | 14.64 | 1595 | 467 | 4.14 / 786.63 | 5 | 88 |
6 | 13 | 302.92 | 20 | 14.81 | 848 | 251 | 4.39 / 786.88 | 5 | 88 |
7 | 13 | 50.04 | 20 | 14.90 | 438 | 131 | 4.52 / 787.01 | 5 | 87 |
8 | 8 | 0.04 | 201 | 14.87 | 333 | 995 | 5.52 / 788.01 | 5 | 139 |
Average= | 17.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 31 | 14.89 | 454 | 210 | 0.21 / 777.37 | 5 | 15 |
2 | 3 | 964.64 | -1 | 15.32 | 0 | 0 | 0.00 / 777.37 | 5 | 15 |
3 | 7 | 2008.44 | 40 | 14.44 | 3317 | 1916 | 2.13 / 779.29 | 15 | 65 |
4 | 13 | 1977.52 | 20 | 14.41 | 3263 | 940 | 3.07 / 780.23 | 5 | 69 |
5 | 13 | 1213.40 | 20 | 14.52 | 2189 | 636 | 3.70 / 780.87 | 5 | 85 |
6 | 13 | 572.44 | 20 | 14.69 | 1226 | 360 | 4.06 / 781.23 | 5 | 90 |
7 | 13 | 86.56 | 20 | 14.87 | 517 | 154 | 4.22 / 781.38 | 5 | 88 |
8 | 8 | 0.08 | 218 | 14.85 | 343 | 1110 | 5.33 / 782.49 | 5 | 133 |
Average= | 17.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 31 | 14.91 | 470 | 217 | 0.22 / 771.96 | 5 | 17 |
2 | 7 | 2005.08 | 40 | 14.45 | 3301 | 1908 | 2.13 / 773.87 | 17 | 62 |
3 | 13 | 1978.96 | 20 | 14.42 | 3282 | 947 | 3.07 / 774.82 | 5 | 66 |
4 | 13 | 1331.68 | 20 | 14.48 | 2356 | 682 | 3.75 / 775.50 | 5 | 78 |
5 | 13 | 880.24 | 20 | 14.58 | 1713 | 500 | 4.25 / 776.00 | 5 | 84 |
6 | 13 | 117.16 | 20 | 14.88 | 513 | 153 | 4.41 / 776.15 | 5 | 62 |
7 | 13 | 21.64 | 20 | 14.91 | 347 | 103 | 4.51 / 776.25 | 5 | 60 |
8 | 8 | 0.08 | 201 | 14.87 | 305 | 912 | 5.42 / 777.17 | 5 | 139 |
Average= | 17.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 31 | 14.91 | 471 | 218 | 0.22 / 766.52 | 5 | 16 |
2 | 7 | 2005.28 | 40 | 14.47 | 3328 | 1926 | 2.14 / 768.44 | 16 | 59 |
3 | 13 | 1976.72 | 20 | 14.44 | 3238 | 935 | 3.08 / 769.38 | 5 | 62 |
4 | 13 | 1374.80 | 20 | 14.49 | 2405 | 697 | 3.78 / 770.08 | 5 | 74 |
5 | 13 | 898.08 | 20 | 14.61 | 1737 | 508 | 4.28 / 770.58 | 5 | 82 |
6 | 13 | 123.92 | 20 | 14.90 | 536 | 160 | 4.44 / 770.74 | 5 | 58 |
7 | 8 | 0.00 | 220 | 14.90 | 305 | 1000 | 5.44 / 771.74 | 5 | 134 |
Average= | 17.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 31 | 14.91 | 473 | 219 | 0.22 / 760.97 | 5 | 16 |
2 | 7 | 2005.92 | 40 | 14.47 | 3328 | 1926 | 2.14 / 762.90 | 16 | 59 |
3 | 13 | 1977.08 | 20 | 14.43 | 3286 | 948 | 3.09 / 763.84 | 5 | 62 |
4 | 13 | 1435.00 | 20 | 14.47 | 2495 | 722 | 3.82 / 764.57 | 5 | 75 |
5 | 13 | 969.92 | 20 | 14.57 | 1839 | 536 | 4.35 / 765.10 | 5 | 82 |
6 | 13 | 160.28 | 20 | 14.89 | 587 | 175 | 4.53 / 765.28 | 5 | 59 |
7 | 8 | 0.24 | 223 | 14.90 | 308 | 1023 | 5.55 / 766.30 | 5 | 137 |
Average= | 18.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 31 | 14.90 | 472 | 218 | 0.22 / 755.42 | 5 | 17 |
2 | 7 | 2009.16 | 40 | 14.47 | 3324 | 1924 | 2.14 / 757.34 | 17 | 58 |
3 | 13 | 1979.84 | 20 | 14.43 | 3304 | 954 | 3.10 / 758.29 | 5 | 62 |
4 | 13 | 1498.08 | 20 | 14.46 | 2579 | 746 | 3.84 / 759.04 | 5 | 73 |
5 | 13 | 927.24 | 20 | 14.59 | 1777 | 519 | 4.36 / 759.56 | 5 | 83 |
6 | 13 | 128.72 | 20 | 14.91 | 536 | 160 | 4.52 / 759.72 | 5 | 57 |
7 | 13 | 23.48 | 20 | 14.93 | 359 | 107 | 4.63 / 759.83 | 5 | 56 |
8 | 8 | 0.12 | 203 | 14.90 | 306 | 926 | 5.55 / 760.75 | 5 | 142 |
Average= | 18.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 31 | 14.92 | 452 | 209 | 0.21 / 749.89 | 5 | 18 |
2 | 7 | 2005.40 | 40 | 14.47 | 3314 | 1918 | 2.13 / 751.80 | 18 | 58 |
3 | 13 | 1976.28 | 20 | 14.44 | 3272 | 945 | 3.07 / 752.75 | 5 | 61 |
4 | 13 | 1367.44 | 20 | 14.49 | 2411 | 699 | 3.77 / 753.45 | 5 | 76 |
5 | 13 | 927.16 | 20 | 14.59 | 1794 | 523 | 4.29 / 753.97 | 5 | 83 |
6 | 13 | 193.28 | 20 | 14.88 | 643 | 191 | 4.49 / 754.16 | 5 | 58 |
7 | 8 | 0.12 | 223 | 14.89 | 312 | 1036 | 5.52 / 755.20 | 5 | 138 |
Average= | 18.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 31 | 14.90 | 476 | 220 | 0.22 / 744.59 | 5 | 20 |
2 | 7 | 2014.80 | 40 | 14.47 | 3311 | 1916 | 2.14 / 746.50 | 20 | 58 |
3 | 13 | 1986.88 | 20 | 14.44 | 3271 | 945 | 3.08 / 747.45 | 5 | 62 |
4 | 13 | 1240.80 | 20 | 14.54 | 2218 | 645 | 3.73 / 748.09 | 5 | 77 |
5 | 13 | 771.44 | 20 | 14.67 | 1550 | 455 | 4.18 / 748.55 | 5 | 81 |
6 | 13 | 66.56 | 20 | 14.93 | 432 | 129 | 4.31 / 748.68 | 5 | 56 |
7 | 8 | 0.12 | 220 | 14.91 | 305 | 1000 | 5.31 / 749.68 | 5 | 134 |
Average= | 19.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 31 | 14.92 | 469 | 217 | 0.22 / 739.04 | 5 | 23 |
2 | 7 | 2007.88 | 40 | 14.47 | 3318 | 1920 | 2.14 / 740.96 | 23 | 58 |
3 | 13 | 1979.64 | 20 | 14.45 | 3247 | 938 | 3.08 / 741.90 | 5 | 61 |
4 | 13 | 1469.60 | 20 | 14.47 | 2564 | 742 | 3.82 / 742.64 | 5 | 74 |
5 | 13 | 902.68 | 20 | 14.61 | 1739 | 508 | 4.33 / 743.15 | 5 | 83 |
6 | 13 | 162.16 | 20 | 14.90 | 601 | 179 | 4.51 / 743.33 | 5 | 59 |
7 | 13 | 15.36 | 20 | 14.94 | 350 | 105 | 4.61 / 743.44 | 5 | 59 |
8 | 8 | -0.04 | 201 | 14.90 | 311 | 931 | 5.54 / 744.37 | 5 | 142 |
Average= | 19.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 30 | 14.92 | 474 | 212 | 0.21 / 733.61 | 5 | 24 |
2 | 3 | 1026.72 | 1 | 15.05 | 1947 | 29 | 0.24 / 733.63 | 5 | 23 |
3 | 7 | 2014.32 | 40 | 14.47 | 3319 | 1921 | 2.16 / 735.56 | 23 | 58 |
4 | 13 | 1986.04 | 20 | 14.44 | 3268 | 944 | 3.11 / 736.50 | 5 | 62 |
5 | 13 | 1388.40 | 20 | 14.50 | 2426 | 704 | 3.81 / 737.20 | 5 | 75 |
6 | 13 | 873.00 | 20 | 14.63 | 1692 | 495 | 4.30 / 737.70 | 5 | 81 |
7 | 13 | 51.52 | 20 | 14.95 | 402 | 120 | 4.43 / 737.82 | 5 | 56 |
8 | 8 | 0.20 | 220 | 14.92 | 307 | 1008 | 5.43 / 738.83 | 5 | 142 |
Average= | 19.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 30 | 14.91 | 476 | 213 | 0.21 / 728.10 | 5 | 26 |
2 | 3 | 1031.88 | 1 | 15.03 | 1954 | 29 | 0.24 / 728.13 | 5 | 30 |
3 | 7 | 2014.04 | 40 | 14.48 | 3326 | 1926 | 2.17 / 730.06 | 30 | 58 |
4 | 13 | 1987.56 | 20 | 14.44 | 3314 | 957 | 3.13 / 731.01 | 5 | 62 |
5 | 13 | 1433.40 | 20 | 14.49 | 2520 | 730 | 3.86 / 731.74 | 5 | 74 |
6 | 13 | 941.16 | 20 | 14.61 | 1794 | 524 | 4.38 / 732.27 | 5 | 80 |
7 | 13 | 48.68 | 20 | 14.95 | 396 | 118 | 4.50 / 732.39 | 5 | 55 |
8 | 8 | 0.16 | 220 | 14.92 | 307 | 1008 | 5.51 / 733.39 | 5 | 134 |
Average= | 20.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 30 | 14.90 | 480 | 215 | 0.21 / 722.56 | 5 | 24 |
2 | 7 | 2010.16 | 40 | 14.48 | 3308 | 1916 | 2.13 / 724.48 | 24 | 59 |
3 | 13 | 1980.36 | 20 | 14.46 | 3243 | 938 | 3.07 / 725.42 | 5 | 62 |
4 | 13 | 1466.24 | 20 | 14.48 | 2547 | 738 | 3.81 / 726.15 | 5 | 74 |
5 | 13 | 1062.64 | 20 | 14.55 | 1959 | 570 | 4.38 / 726.72 | 5 | 81 |
6 | 13 | 90.04 | 20 | 14.93 | 471 | 141 | 4.52 / 726.86 | 5 | 57 |
7 | 8 | -0.04 | 220 | 14.91 | 312 | 1023 | 5.54 / 727.89 | 5 | 131 |
Average= | 20.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 30 | 14.90 | 497 | 222 | 0.22 / 717.08 | 5 | 31 |
2 | 7 | 2005.40 | 41 | 14.46 | 3315 | 1965 | 2.19 / 719.05 | 31 | 61 |
3 | 13 | 1976.48 | 20 | 14.43 | 3268 | 943 | 3.13 / 719.99 | 5 | 64 |
4 | 13 | 1329.32 | 20 | 14.51 | 2358 | 684 | 3.81 / 720.67 | 5 | 78 |
5 | 13 | 889.72 | 20 | 14.61 | 1728 | 505 | 4.32 / 721.18 | 5 | 84 |
6 | 13 | 113.36 | 20 | 14.91 | 500 | 149 | 4.47 / 721.33 | 5 | 62 |
7 | 8 | 0.12 | 220 | 14.90 | 311 | 1019 | 5.49 / 722.35 | 5 | 140 |
Average= | 21.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 30 | 14.91 | 494 | 221 | 0.22 / 711.63 | 5 | 31 |
2 | 7 | 2004.40 | 40 | 14.48 | 3330 | 1929 | 2.15 / 713.56 | 31 | 59 |
3 | 13 | 1975.92 | 20 | 14.45 | 3278 | 947 | 3.10 / 714.51 | 5 | 62 |
4 | 13 | 1363.84 | 20 | 14.50 | 2449 | 710 | 3.81 / 715.22 | 5 | 77 |
5 | 13 | 879.08 | 20 | 14.63 | 1716 | 502 | 4.31 / 715.72 | 5 | 82 |
6 | 13 | 17.32 | 20 | 14.96 | 361 | 108 | 4.42 / 715.83 | 5 | 58 |
7 | 8 | 0.04 | 220 | 14.91 | 314 | 1030 | 5.45 / 716.86 | 5 | 138 |
Average= | 21.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 30 | 14.89 | 504 | 225 | 0.23 / 706.11 | 5 | 33 |
2 | 7 | 2004.32 | 40 | 14.47 | 3342 | 1934 | 2.16 / 708.04 | 33 | 60 |
3 | 13 | 1974.24 | 20 | 14.44 | 3299 | 953 | 3.11 / 708.99 | 5 | 64 |
4 | 13 | 1538.68 | 20 | 14.46 | 2665 | 771 | 3.88 / 709.76 | 5 | 74 |
5 | 13 | 840.12 | 20 | 14.64 | 1672 | 490 | 4.37 / 710.25 | 5 | 83 |
6 | 8 | 0.36 | 240 | 14.92 | 323 | 1157 | 5.53 / 711.41 | 5 | 134 |
Average= | 22.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 30 | 14.90 | 479 | 214 | 0.21 / 700.38 | 5 | 32 |
2 | 7 | 2008.28 | 41 | 14.47 | 3347 | 1986 | 2.20 / 702.37 | 32 | 61 |
3 | 13 | 1907.84 | 20 | 14.45 | 3191 | 922 | 3.12 / 703.29 | 5 | 66 |
4 | 13 | 1479.76 | 20 | 14.47 | 2588 | 749 | 3.87 / 704.04 | 5 | 76 |
5 | 13 | 1069.96 | 20 | 14.55 | 1980 | 576 | 4.45 / 704.62 | 5 | 82 |
6 | 13 | 155.84 | 20 | 14.90 | 604 | 180 | 4.63 / 704.80 | 5 | 63 |
7 | 8 | -0.04 | 223 | 14.90 | 327 | 1087 | 5.71 / 705.88 | 5 | 150 |
Average= | 22.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 29 | 14.91 | 490 | 212 | 0.21 / 694.91 | 5 | 31 |
2 | 7 | 2005.84 | 40 | 14.48 | 3309 | 1917 | 2.13 / 696.82 | 12 | 60 |
3 | 13 | 1975.00 | 20 | 14.45 | 3286 | 950 | 3.08 / 697.77 | 5 | 65 |
4 | 13 | 1417.68 | 20 | 14.50 | 2476 | 718 | 3.80 / 698.49 | 5 | 76 |
5 | 13 | 894.20 | 20 | 14.62 | 1743 | 510 | 4.31 / 699.00 | 5 | 84 |
6 | 8 | 0.04 | 242 | 14.91 | 324 | 1169 | 5.47 / 700.17 | 5 | 144 |
Average= | 23.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 29 | 14.92 | 480 | 208 | 0.21 / 689.40 | 5 | 33 |
2 | 7 | 2011.76 | 40 | 14.49 | 3336 | 1934 | 2.14 / 691.34 | 33 | 61 |
3 | 13 | 1983.96 | 20 | 14.45 | 3313 | 957 | 3.10 / 692.29 | 5 | 64 |
4 | 13 | 1416.40 | 20 | 14.50 | 2495 | 724 | 3.82 / 693.02 | 5 | 77 |
5 | 13 | 892.08 | 20 | 14.63 | 1732 | 507 | 4.33 / 693.52 | 5 | 85 |
6 | 13 | 76.28 | 20 | 14.95 | 443 | 132 | 4.46 / 693.66 | 5 | 61 |
7 | 8 | 0.24 | 220 | 14.92 | 316 | 1037 | 5.50 / 694.69 | 5 | 135 |
Average= | 23.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 29 | 14.90 | 504 | 218 | 0.22 / 683.93 | 5 | 34 |
2 | 7 | 2011.48 | 40 | 14.49 | 3320 | 1924 | 2.14 / 685.85 | 34 | 62 |
3 | 13 | 1981.40 | 20 | 14.45 | 3277 | 947 | 3.09 / 686.80 | 5 | 65 |
4 | 13 | 1465.48 | 20 | 14.50 | 2540 | 737 | 3.83 / 687.54 | 5 | 77 |
5 | 13 | 768.56 | 20 | 14.68 | 1532 | 450 | 4.28 / 687.99 | 5 | 86 |
6 | 13 | 147.68 | 20 | 14.92 | 574 | 171 | 4.45 / 688.16 | 5 | 65 |
7 | 8 | -0.08 | 218 | 14.92 | 319 | 1038 | 5.48 / 689.19 | 5 | 130 |
Average= | 24.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 29 | 14.90 | 501 | 216 | 0.22 / 678.54 | 5 | 34 |
2 | 7 | 2008.92 | 41 | 14.47 | 3312 | 1965 | 2.18 / 680.50 | 34 | 64 |
3 | 13 | 1798.12 | 20 | 14.49 | 3031 | 878 | 3.06 / 681.38 | 5 | 70 |
4 | 13 | 1250.44 | 20 | 14.54 | 2237 | 651 | 3.71 / 682.03 | 5 | 81 |
5 | 13 | 714.48 | 20 | 14.69 | 1465 | 430 | 4.14 / 682.46 | 5 | 88 |
6 | 13 | 210.40 | 20 | 14.88 | 671 | 200 | 4.34 / 682.66 | 5 | 73 |
7 | 8 | 0.32 | 218 | 14.90 | 323 | 1049 | 5.39 / 683.71 | 5 | 138 |
Average= | 25.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 29 | 14.91 | 507 | 219 | 0.22 / 673.03 | 5 | 33 |
2 | 7 | 2009.20 | 40 | 14.48 | 3323 | 1925 | 2.14 / 674.95 | 33 | 63 |
3 | 13 | 1838.84 | 20 | 14.48 | 3099 | 897 | 3.04 / 675.85 | 5 | 69 |
4 | 13 | 1315.08 | 20 | 14.53 | 2346 | 682 | 3.72 / 676.53 | 5 | 79 |
5 | 13 | 844.52 | 20 | 14.64 | 1656 | 485 | 4.21 / 677.02 | 5 | 87 |
6 | 13 | 232.88 | 20 | 14.88 | 716 | 213 | 4.42 / 677.23 | 5 | 71 |
7 | 8 | -0.12 | 223 | 14.91 | 328 | 1091 | 5.51 / 678.32 | 5 | 138 |
Average= | 26.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 29 | 14.91 | 489 | 211 | 0.21 / 667.67 | 5 | 33 |
2 | 7 | 2007.36 | 40 | 14.48 | 3314 | 1919 | 2.13 / 669.59 | 33 | 63 |
3 | 13 | 1976.24 | 20 | 14.45 | 3301 | 954 | 3.08 / 670.55 | 5 | 67 |
4 | 13 | 1266.88 | 20 | 14.54 | 2270 | 660 | 3.75 / 671.21 | 5 | 82 |
5 | 13 | 783.24 | 20 | 14.67 | 1571 | 461 | 4.21 / 671.67 | 5 | 87 |
6 | 8 | -0.12 | 233 | 14.92 | 328 | 1140 | 5.35 / 672.81 | 5 | 137 |
Average= | 26.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 29 | 14.90 | 484 | 209 | 0.21 / 662.09 | 5 | 31 |
2 | 7 | 2013.00 | 40 | 14.48 | 3328 | 1928 | 2.14 / 664.02 | 31 | 63 |
3 | 13 | 1983.28 | 20 | 14.45 | 3307 | 956 | 3.09 / 664.98 | 5 | 68 |
4 | 13 | 1560.56 | 20 | 14.46 | 2707 | 783 | 3.88 / 665.76 | 5 | 77 |
5 | 13 | 812.60 | 20 | 14.66 | 1591 | 466 | 4.34 / 666.23 | 5 | 86 |
6 | 13 | 136.40 | 20 | 14.92 | 568 | 169 | 4.51 / 666.40 | 5 | 72 |
7 | 8 | 0.20 | 220 | 14.91 | 325 | 1066 | 5.58 / 667.46 | 5 | 137 |
Average= | 27.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 29 | 14.90 | 498 | 215 | 0.22 / 656.50 | 5 | 32 |
2 | 7 | 2010.16 | 40 | 14.48 | 3327 | 1927 | 2.14 / 658.42 | 32 | 62 |
3 | 13 | 1978.68 | 20 | 14.46 | 3284 | 950 | 3.09 / 659.37 | 5 | 66 |
4 | 13 | 1361.84 | 20 | 14.52 | 2417 | 702 | 3.79 / 660.08 | 5 | 79 |
5 | 13 | 845.00 | 20 | 14.65 | 1631 | 478 | 4.27 / 660.55 | 5 | 85 |
6 | 13 | 344.28 | 20 | 14.83 | 896 | 266 | 4.54 / 660.82 | 5 | 80 |
7 | 8 | 0.00 | 220 | 14.91 | 325 | 1066 | 5.60 / 661.89 | 5 | 132 |
Average= | 28.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 29 | 14.90 | 486 | 210 | 0.21 / 651.02 | 5 | 30 |
2 | 7 | 2003.44 | 40 | 14.48 | 3316 | 1921 | 2.13 / 652.94 | 30 | 63 |
3 | 13 | 1974.44 | 20 | 14.45 | 3300 | 954 | 3.08 / 653.89 | 5 | 69 |
4 | 13 | 1234.68 | 20 | 14.55 | 2218 | 645 | 3.73 / 654.54 | 5 | 80 |
5 | 13 | 825.08 | 20 | 14.65 | 1605 | 470 | 4.20 / 655.01 | 5 | 86 |
6 | 13 | 175.52 | 20 | 14.90 | 638 | 190 | 4.39 / 655.20 | 5 | 70 |
7 | 8 | 0.16 | 220 | 14.90 | 330 | 1082 | 5.47 / 656.28 | 5 | 132 |
Average= | 29.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 29 | 14.92 | 493 | 213 | 0.21 / 645.39 | 5 | 29 |
2 | 7 | 2015.08 | 40 | 14.48 | 3329 | 1928 | 2.14 / 647.31 | 29 | 63 |
3 | 13 | 1989.84 | 20 | 14.45 | 3300 | 954 | 3.10 / 648.27 | 5 | 66 |
4 | 13 | 1381.88 | 20 | 14.52 | 2435 | 707 | 3.80 / 648.98 | 5 | 80 |
5 | 13 | 962.24 | 20 | 14.60 | 1793 | 524 | 4.33 / 649.50 | 5 | 85 |
6 | 13 | 294.56 | 20 | 14.85 | 812 | 241 | 4.57 / 649.74 | 5 | 75 |
7 | 8 | 0.08 | 223 | 14.90 | 322 | 1070 | 5.64 / 650.81 | 5 | 137 |
Average= | 30.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 29 | 14.91 | 490 | 212 | 0.21 / 639.91 | 5 | 31 |
2 | 7 | 2010.80 | 40 | 14.49 | 3313 | 1920 | 2.13 / 641.83 | 31 | 64 |
3 | 13 | 1980.92 | 20 | 14.45 | 3272 | 946 | 3.08 / 642.77 | 5 | 66 |
4 | 13 | 1418.60 | 20 | 14.51 | 2470 | 717 | 3.79 / 643.49 | 5 | 80 |
5 | 13 | 811.92 | 20 | 14.66 | 1600 | 469 | 4.26 / 643.96 | 5 | 88 |
6 | 13 | 159.96 | 20 | 14.92 | 587 | 175 | 4.44 / 644.14 | 5 | 67 |
7 | 8 | 0.04 | 220 | 14.92 | 316 | 1037 | 5.48 / 645.17 | 5 | 134 |
Average= | 32.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 29 | 14.93 | 474 | 205 | 0.21 / 634.37 | 5 | 28 |
2 | 7 | 2003.40 | 40 | 14.49 | 3308 | 1917 | 2.12 / 636.29 | 28 | 64 |
3 | 13 | 1973.20 | 20 | 14.45 | 3273 | 946 | 3.07 / 637.23 | 5 | 68 |
4 | 13 | 1427.24 | 20 | 14.50 | 2510 | 728 | 3.80 / 637.96 | 5 | 80 |
5 | 13 | 824.88 | 20 | 14.65 | 1619 | 474 | 4.27 / 638.44 | 5 | 88 |
6 | 13 | 210.04 | 20 | 14.89 | 669 | 199 | 4.47 / 638.63 | 5 | 70 |
7 | 8 | 0.24 | 220 | 14.91 | 324 | 1063 | 5.53 / 639.70 | 5 | 132 |
Average= | 33.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 29 | 14.92 | 492 | 213 | 0.21 / 628.89 | 5 | 27 |
2 | 7 | 2011.04 | 40 | 14.49 | 3320 | 1924 | 2.14 / 630.82 | 27 | 63 |
3 | 13 | 1982.60 | 20 | 14.45 | 3274 | 946 | 3.08 / 631.76 | 5 | 67 |
4 | 13 | 1477.40 | 20 | 14.49 | 2583 | 749 | 3.83 / 632.51 | 5 | 79 |
5 | 13 | 764.84 | 20 | 14.68 | 1549 | 455 | 4.29 / 632.97 | 5 | 88 |
6 | 13 | 127.04 | 20 | 14.93 | 541 | 162 | 4.45 / 633.13 | 5 | 63 |
7 | 8 | 0.36 | 218 | 14.93 | 318 | 1035 | 5.48 / 634.16 | 5 | 132 |
Average= | 35.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 29 | 14.91 | 470 | 203 | 0.20 / 623.44 | 5 | 25 |
2 | 7 | 2013.96 | 40 | 14.48 | 3351 | 1941 | 2.14 / 625.38 | 25 | 62 |
3 | 13 | 1985.84 | 20 | 14.45 | 3311 | 957 | 3.10 / 626.34 | 5 | 65 |
4 | 13 | 1381.68 | 20 | 14.51 | 2438 | 708 | 3.81 / 627.04 | 5 | 78 |
5 | 13 | 750.16 | 20 | 14.69 | 1522 | 447 | 4.26 / 627.49 | 5 | 85 |
6 | 13 | 106.36 | 20 | 14.94 | 507 | 151 | 4.41 / 627.64 | 5 | 63 |
7 | 8 | -0.08 | 218 | 14.92 | 319 | 1038 | 5.44 / 628.68 | 5 | 135 |
Average= | 36.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 29 | 14.92 | 471 | 204 | 0.20 / 617.76 | 5 | 22 |
2 | 7 | 2012.40 | 40 | 14.48 | 3329 | 1928 | 2.13 / 619.68 | 11 | 62 |
3 | 13 | 1983.00 | 20 | 14.44 | 3303 | 954 | 3.09 / 620.64 | 5 | 65 |
4 | 13 | 1394.92 | 20 | 14.50 | 2485 | 721 | 3.81 / 621.36 | 5 | 78 |
5 | 13 | 862.08 | 20 | 14.63 | 1711 | 501 | 4.31 / 621.86 | 5 | 87 |
6 | 13 | 406.04 | 20 | 14.80 | 995 | 295 | 4.60 / 622.15 | 5 | 76 |
7 | 8 | 0.00 | 223 | 14.90 | 326 | 1083 | 5.68 / 623.24 | 5 | 138 |
Average= | 38.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 29 | 14.93 | 472 | 204 | 0.20 / 612.31 | 5 | 23 |
2 | 7 | 2004.36 | 40 | 14.49 | 3332 | 1931 | 2.14 / 614.24 | 7 | 61 |
3 | 13 | 1972.76 | 20 | 14.46 | 3276 | 947 | 3.08 / 615.19 | 5 | 65 |
4 | 13 | 1370.32 | 20 | 14.52 | 2434 | 707 | 3.79 / 615.90 | 5 | 78 |
5 | 13 | 810.40 | 20 | 14.67 | 1603 | 470 | 4.26 / 616.37 | 5 | 84 |
6 | 13 | 115.12 | 20 | 14.94 | 533 | 159 | 4.42 / 616.52 | 5 | 60 |
7 | 8 | 0.04 | 219 | 14.93 | 314 | 1027 | 5.45 / 617.55 | 5 | 144 |
Average= | 41.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 29 | 14.92 | 480 | 208 | 0.21 / 606.87 | 5 | 23 |
2 | 7 | 2008.20 | 40 | 14.49 | 3339 | 1935 | 2.14 / 608.81 | 23 | 62 |
3 | 13 | 1980.88 | 20 | 14.46 | 3287 | 951 | 3.09 / 609.76 | 5 | 65 |
4 | 13 | 1379.44 | 20 | 14.52 | 2443 | 709 | 3.80 / 610.47 | 5 | 78 |
5 | 13 | 813.68 | 20 | 14.67 | 1624 | 476 | 4.28 / 610.94 | 5 | 86 |
6 | 13 | 73.48 | 20 | 14.96 | 447 | 134 | 4.41 / 611.08 | 5 | 62 |
7 | 8 | 0.28 | 218 | 14.93 | 316 | 1028 | 5.44 / 612.11 | 5 | 136 |
Average= | 43.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 28 | 14.93 | 477 | 199 | 0.20 / 601.34 | 5 | 21 |
2 | 7 | 2013.96 | 40 | 14.49 | 3337 | 1934 | 2.13 / 603.27 | 9 | 62 |
3 | 13 | 1985.72 | 20 | 14.45 | 3327 | 962 | 3.10 / 604.23 | 5 | 65 |
4 | 13 | 1356.48 | 20 | 14.53 | 2385 | 693 | 3.79 / 604.93 | 5 | 78 |
5 | 13 | 942.08 | 20 | 14.62 | 1795 | 525 | 4.31 / 605.45 | 5 | 85 |
6 | 13 | 45.36 | 20 | 14.95 | 419 | 125 | 4.44 / 605.58 | 5 | 65 |
7 | 8 | -0.12 | 220 | 14.92 | 331 | 1086 | 5.52 / 606.66 | 6 | 133 |
Average= | 46.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 28 | 14.93 | 486 | 203 | 0.20 / 595.83 | 5 | 21 |
2 | 7 | 2003.96 | 40 | 14.50 | 3303 | 1916 | 2.12 / 597.75 | 21 | 63 |
3 | 13 | 1972.12 | 20 | 14.48 | 3267 | 946 | 3.07 / 598.70 | 5 | 67 |
4 | 13 | 1253.44 | 20 | 14.57 | 2245 | 654 | 3.72 / 599.35 | 5 | 81 |
5 | 13 | 954.20 | 20 | 14.63 | 1805 | 528 | 4.25 / 599.88 | 5 | 86 |
6 | 13 | 123.04 | 20 | 14.93 | 561 | 168 | 4.41 / 600.05 | 5 | 69 |
7 | 8 | 0.20 | 220 | 14.92 | 333 | 1093 | 5.51 / 601.14 | 5 | 134 |
Average= | 50.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 28 | 14.93 | 489 | 204 | 0.20 / 590.41 | 5 | 22 |
2 | 7 | 2014.04 | 40 | 14.49 | 3316 | 1922 | 2.13 / 592.34 | 22 | 64 |
3 | 13 | 1985.96 | 20 | 14.46 | 3295 | 953 | 3.08 / 593.29 | 5 | 67 |
4 | 13 | 1366.00 | 20 | 14.53 | 2404 | 699 | 3.78 / 593.99 | 5 | 80 |
5 | 13 | 687.84 | 20 | 14.72 | 1420 | 418 | 4.20 / 594.41 | 5 | 88 |
6 | 13 | 75.04 | 20 | 14.95 | 473 | 141 | 4.34 / 594.55 | 5 | 73 |
7 | 8 | 0.00 | 218 | 14.92 | 333 | 1083 | 5.42 / 595.63 | 5 | 130 |
Average= | 54.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 28 | 14.92 | 483 | 202 | 0.20 / 585.08 | 5 | 21 |
2 | 7 | 2004.92 | 40 | 14.50 | 3304 | 1916 | 2.12 / 587.00 | 21 | 65 |
3 | 13 | 1904.04 | 20 | 14.47 | 3196 | 925 | 3.04 / 587.93 | 5 | 70 |
4 | 13 | 1264.80 | 20 | 14.56 | 2265 | 660 | 3.70 / 588.59 | 5 | 83 |
5 | 13 | 688.00 | 20 | 14.72 | 1428 | 420 | 4.12 / 589.01 | 5 | 88 |
6 | 13 | 49.84 | 20 | 14.96 | 429 | 128 | 4.25 / 589.13 | 5 | 74 |
7 | 8 | 0.00 | 218 | 14.92 | 331 | 1077 | 5.33 / 590.21 | 5 | 133 |
Average= | 59.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 28 | 14.92 | 485 | 203 | 0.20 / 579.73 | 5 | 22 |
2 | 7 | 2004.20 | 40 | 14.50 | 3286 | 1906 | 2.11 / 581.64 | 22 | 66 |
3 | 13 | 1972.52 | 20 | 14.46 | 3274 | 947 | 3.06 / 582.59 | 5 | 70 |
4 | 13 | 1285.80 | 20 | 14.55 | 2297 | 668 | 3.72 / 583.25 | 5 | 83 |
5 | 13 | 685.36 | 20 | 14.72 | 1423 | 419 | 4.14 / 583.67 | 5 | 89 |
6 | 13 | 36.36 | 20 | 14.96 | 414 | 124 | 4.27 / 583.80 | 5 | 74 |
7 | 8 | 0.16 | 218 | 14.92 | 334 | 1086 | 5.35 / 584.88 | 5 | 129 |
Average= | 64.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 28 | 14.92 | 487 | 203 | 0.20 / 574.12 | 5 | 21 |
2 | 7 | 2008.16 | 41 | 14.48 | 3323 | 1973 | 2.18 / 576.09 | 6 | 65 |
3 | 13 | 1978.12 | 20 | 14.45 | 3310 | 957 | 3.13 / 577.05 | 5 | 69 |
4 | 13 | 1402.00 | 20 | 14.51 | 2480 | 720 | 3.85 / 577.77 | 5 | 81 |
5 | 13 | 885.28 | 20 | 14.65 | 1693 | 496 | 4.35 / 578.26 | 5 | 86 |
6 | 13 | 124.36 | 20 | 14.93 | 545 | 163 | 4.51 / 578.42 | 5 | 78 |
7 | 13 | 18.16 | 20 | 14.96 | 377 | 113 | 4.62 / 578.54 | 5 | 76 |
8 | 8 | 0.20 | 199 | 14.91 | 333 | 988 | 5.61 / 579.52 | 5 | 134 |
9 | 14 | -0.04 | 1 | 14.88 | 337 | 5 | 5.62 / 579.53 | 42 | 121 |
Average= | 72.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 28 | 14.93 | 469 | 196 | 0.20 / 568.74 | 5 | 19 |
2 | 7 | 2004.28 | 40 | 14.50 | 3295 | 1911 | 2.11 / 570.65 | 19 | 64 |
3 | 13 | 1979.32 | 20 | 14.47 | 3259 | 943 | 3.05 / 571.59 | 5 | 67 |
4 | 13 | 1259.00 | 20 | 14.56 | 2246 | 654 | 3.70 / 572.25 | 5 | 82 |
5 | 13 | 674.48 | 20 | 14.72 | 1417 | 417 | 4.12 / 572.66 | 5 | 90 |
6 | 13 | 100.12 | 20 | 14.93 | 507 | 151 | 4.27 / 572.82 | 5 | 75 |
7 | 8 | -0.08 | 221 | 14.91 | 333 | 1097 | 5.37 / 573.91 | 5 | 142 |
Average= | 81.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 29 | 14.92 | 467 | 202 | 0.20 / 563.32 | 5 | 18 |
2 | 7 | 2003.60 | 41 | 14.50 | 3314 | 1970 | 2.17 / 565.29 | 18 | 62 |
3 | 13 | 1974.52 | 20 | 14.48 | 3256 | 943 | 3.12 / 566.24 | 5 | 65 |
4 | 13 | 1183.68 | 20 | 14.61 | 2114 | 618 | 3.73 / 566.85 | 5 | 80 |
5 | 13 | 816.60 | 20 | 14.68 | 1616 | 474 | 4.21 / 567.33 | 5 | 85 |
6 | 13 | 139.16 | 20 | 14.93 | 560 | 167 | 4.37 / 567.50 | 5 | 71 |
7 | 8 | 0.12 | 218 | 14.92 | 322 | 1047 | 5.42 / 568.54 | 5 | 134 |
Average= | 94.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 29 | 14.93 | 481 | 208 | 0.21 / 557.86 | 5 | 20 |
2 | 7 | 2012.12 | 40 | 14.50 | 3318 | 1924 | 2.13 / 559.78 | 20 | 63 |
3 | 13 | 1985.72 | 20 | 14.47 | 3301 | 955 | 3.09 / 560.74 | 5 | 67 |
4 | 13 | 1311.84 | 20 | 14.56 | 2345 | 683 | 3.77 / 561.42 | 5 | 80 |
5 | 13 | 682.12 | 20 | 14.73 | 1420 | 418 | 4.19 / 561.84 | 5 | 87 |
6 | 13 | 187.84 | 20 | 14.90 | 659 | 196 | 4.39 / 562.04 | 5 | 76 |
7 | 8 | 0.08 | 220 | 14.92 | 330 | 1083 | 5.47 / 563.12 | 5 | 139 |
Average= | 112.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 29 | 14.94 | 483 | 209 | 0.21 / 552.32 | 5 | 20 |
2 | 10 | 1001.12 | 3 | 14.96 | 1919 | 86 | 0.30 / 552.41 | 5 | 56 |
3 | 3 | 906.24 | -1 | 15.35 | 0 | 0 | 0.09 / 552.41 | 5 | 56 |
4 | 7 | 2010.64 | 40 | 14.50 | 3334 | 1934 | 2.23 / 554.34 | 56 | 64 |
5 | 13 | 1980.40 | 20 | 14.48 | 3285 | 951 | 3.18 / 555.29 | 5 | 67 |
6 | 13 | 1353.00 | 20 | 14.54 | 2389 | 695 | 3.88 / 555.99 | 5 | 78 |
7 | 13 | 751.96 | 20 | 14.70 | 1541 | 453 | 4.33 / 556.44 | 5 | 87 |
8 | 13 | 36.20 | 20 | 14.96 | 412 | 123 | 4.45 / 556.56 | 5 | 69 |
9 | 8 | 0.00 | 220 | 14.93 | 331 | 1087 | 5.54 / 557.65 | 5 | 139 |
Average= | 139.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 28 | 14.92 | 477 | 199 | 0.20 / 546.78 | 5 | 22 |
2 | 10 | 1015.20 | 3 | 14.96 | 1940 | 87 | 0.29 / 546.87 | 5 | 59 |
3 | 3 | 956.96 | -1 | 15.34 | 0 | 0 | 0.09 / 546.87 | 5 | 59 |
4 | 7 | 2012.36 | 40 | 14.51 | 3303 | 1917 | 2.20 / 548.79 | 59 | 63 |
5 | 13 | 1984.52 | 20 | 14.48 | 3280 | 950 | 3.15 / 549.74 | 5 | 67 |
6 | 13 | 1337.00 | 20 | 14.55 | 2371 | 690 | 3.84 / 550.43 | 5 | 80 |
7 | 13 | 785.52 | 20 | 14.70 | 1560 | 459 | 4.30 / 550.89 | 5 | 87 |
8 | 13 | 115.56 | 20 | 14.95 | 521 | 156 | 4.46 / 551.04 | 5 | 71 |
9 | 8 | 0.08 | 220 | 14.94 | 326 | 1071 | 5.53 / 552.11 | 5 | 138 |
Average= | 184.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 29 | 14.94 | 476 | 206 | 0.21 / 541.04 | 5 | 26 |
2 | 7 | 2012.08 | 40 | 14.51 | 3319 | 1926 | 2.13 / 542.97 | 26 | 64 |
3 | 13 | 1980.52 | 20 | 14.48 | 3290 | 953 | 3.09 / 543.92 | 5 | 68 |
4 | 13 | 1417.08 | 20 | 14.54 | 2469 | 718 | 3.80 / 544.64 | 5 | 79 |
5 | 13 | 846.36 | 20 | 14.68 | 1647 | 484 | 4.29 / 545.12 | 5 | 87 |
6 | 13 | 538.12 | 20 | 14.77 | 1194 | 353 | 4.64 / 545.48 | 5 | 88 |
7 | 8 | 0.04 | 223 | 14.92 | 333 | 1108 | 5.75 / 546.58 | 5 | 136 |
Average= | 273.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 29 | 14.92 | 495 | 214 | 0.21 / 535.75 | 5 | 28 |
2 | 7 | 2008.40 | 40 | 14.51 | 3310 | 1921 | 2.14 / 537.67 | 28 | 64 |
3 | 13 | 1978.04 | 20 | 14.48 | 3293 | 954 | 3.09 / 538.62 | 5 | 69 |
4 | 13 | 1264.28 | 20 | 14.58 | 2251 | 656 | 3.75 / 539.28 | 5 | 83 |
5 | 13 | 640.72 | 20 | 14.75 | 1338 | 395 | 4.14 / 539.67 | 5 | 90 |
6 | 13 | 19.24 | 20 | 14.98 | 368 | 110 | 4.25 / 539.78 | 5 | 72 |
7 | 8 | 0.20 | 214 | 14.94 | 329 | 1052 | 5.30 / 540.84 | 5 | 130 |
Average= | 540.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 30 | 14.92 | 488 | 218 | 0.22 / 530.32 | 5 | 34 |
2 | 7 | 2008.60 | 40 | 14.51 | 3315 | 1924 | 2.14 / 532.24 | 34 | 65 |
3 | 13 | 1980.68 | 20 | 14.48 | 3240 | 938 | 3.08 / 533.18 | 5 | 69 |
4 | 13 | 1380.56 | 20 | 14.54 | 2436 | 708 | 3.79 / 533.89 | 5 | 80 |
5 | 13 | 753.68 | 20 | 14.71 | 1518 | 447 | 4.24 / 534.34 | 5 | 91 |
6 | 13 | 15.76 | 20 | 14.98 | 380 | 114 | 4.35 / 534.45 | 5 | 70 |
7 | 8 | 0.16 | 216 | 14.93 | 336 | 1084 | 5.43 / 535.53 | 5 | 129 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 30 | 14.91 | 504 | 225 | 0.23 / 524.82 | 5 | 35 |
2 | 7 | 2010.32 | 41 | 14.51 | 3306 | 1967 | 2.19 / 526.79 | 35 | 64 |
3 | 13 | 1874.44 | 20 | 14.49 | 3130 | 907 | 3.10 / 527.70 | 5 | 69 |
4 | 13 | 1578.32 | 20 | 14.49 | 2720 | 788 | 3.89 / 528.48 | 5 | 77 |
5 | 13 | 705.92 | 20 | 14.73 | 1450 | 427 | 4.31 / 528.91 | 5 | 87 |
6 | 13 | 14.52 | 20 | 14.98 | 373 | 112 | 4.43 / 529.02 | 5 | 67 |
7 | 8 | 0.08 | 216 | 14.93 | 334 | 1077 | 5.50 / 530.10 | 5 | 139 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 30 | 14.92 | 488 | 218 | 0.22 / 519.17 | 5 | 37 |
2 | 7 | 2013.48 | 40 | 14.49 | 3329 | 1929 | 2.15 / 521.10 | 6 | 64 |
3 | 13 | 1981.96 | 20 | 14.46 | 3301 | 955 | 3.10 / 522.05 | 5 | 68 |
4 | 13 | 1510.84 | 20 | 14.50 | 2602 | 755 | 3.86 / 522.81 | 5 | 78 |
5 | 13 | 1073.76 | 20 | 14.58 | 1977 | 576 | 4.43 / 523.38 | 5 | 86 |
6 | 13 | 64.00 | 20 | 14.96 | 446 | 133 | 4.57 / 523.52 | 5 | 66 |
7 | 8 | 0.20 | 220 | 14.93 | 329 | 1081 | 5.65 / 524.60 | 5 | 129 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 30 | 14.92 | 496 | 222 | 0.22 / 513.65 | 5 | 38 |
2 | 7 | 2005.00 | 40 | 14.51 | 3326 | 1930 | 2.15 / 515.58 | 38 | 64 |
3 | 13 | 1973.72 | 20 | 14.48 | 3281 | 950 | 3.10 / 516.53 | 5 | 67 |
4 | 13 | 1322.88 | 20 | 14.56 | 2352 | 685 | 3.79 / 517.21 | 5 | 81 |
5 | 13 | 877.72 | 20 | 14.66 | 1727 | 506 | 4.29 / 517.72 | 5 | 89 |
6 | 13 | 61.52 | 20 | 14.97 | 444 | 133 | 4.43 / 517.85 | 5 | 65 |
7 | 8 | 0.04 | 220 | 14.93 | 334 | 1097 | 5.52 / 518.95 | 5 | 140 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 30 | 14.92 | 509 | 228 | 0.23 / 508.27 | 5 | 39 |
2 | 7 | 2004.96 | 40 | 14.51 | 3321 | 1928 | 2.16 / 510.20 | 39 | 63 |
3 | 13 | 1974.32 | 20 | 14.47 | 3312 | 958 | 3.11 / 511.16 | 5 | 67 |
4 | 13 | 1249.04 | 20 | 14.59 | 2243 | 655 | 3.77 / 511.82 | 5 | 81 |
5 | 13 | 708.44 | 20 | 14.75 | 1445 | 426 | 4.19 / 512.24 | 5 | 85 |
6 | 8 | 0.28 | 238 | 14.94 | 333 | 1184 | 5.38 / 513.43 | 5 | 138 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 30 | 14.92 | 508 | 227 | 0.23 / 502.76 | 5 | 38 |
2 | 7 | 2014.36 | 40 | 14.50 | 3334 | 1934 | 2.16 / 504.69 | 38 | 63 |
3 | 13 | 1984.20 | 20 | 14.47 | 3319 | 961 | 3.12 / 505.65 | 5 | 67 |
4 | 13 | 1325.36 | 20 | 14.56 | 2347 | 683 | 3.81 / 506.34 | 5 | 81 |
5 | 13 | 914.84 | 20 | 14.65 | 1775 | 520 | 4.33 / 506.86 | 5 | 88 |
6 | 8 | -0.20 | 240 | 14.94 | 332 | 1190 | 5.52 / 508.05 | 5 | 135 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 30 | 14.91 | 525 | 235 | 0.23 / 497.19 | 5 | 39 |
2 | 7 | 2004.84 | 40 | 14.52 | 3318 | 1927 | 2.16 / 499.12 | 39 | 63 |
3 | 13 | 1975.76 | 20 | 14.48 | 3301 | 956 | 3.12 / 500.07 | 5 | 67 |
4 | 13 | 1376.76 | 20 | 14.55 | 2458 | 715 | 3.83 / 500.79 | 5 | 80 |
5 | 13 | 921.72 | 20 | 14.65 | 1798 | 527 | 4.36 / 501.32 | 5 | 87 |
6 | 8 | 0.32 | 240 | 14.94 | 339 | 1216 | 5.58 / 502.53 | 5 | 136 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 30 | 14.93 | 502 | 225 | 0.22 / 491.63 | 5 | 39 |
2 | 7 | 2012.48 | 40 | 14.50 | 3355 | 1946 | 2.17 / 493.57 | 7 | 64 |
3 | 13 | 1983.52 | 20 | 14.47 | 3308 | 957 | 3.13 / 494.53 | 5 | 66 |
4 | 13 | 1283.64 | 20 | 14.58 | 2298 | 670 | 3.80 / 495.20 | 5 | 82 |
5 | 13 | 975.88 | 20 | 14.63 | 1862 | 545 | 4.34 / 495.74 | 5 | 86 |
6 | 13 | 15.24 | 20 | 14.98 | 377 | 113 | 4.46 / 495.86 | 5 | 66 |
7 | 8 | 0.04 | 216 | 14.93 | 341 | 1100 | 5.56 / 496.96 | 5 | 136 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 29 | 14.92 | 497 | 215 | 0.22 / 486.03 | 5 | 37 |
2 | 7 | 2004.80 | 40 | 14.53 | 3311 | 1924 | 2.14 / 487.96 | 12 | 62 |
3 | 13 | 1975.48 | 20 | 14.50 | 3303 | 958 | 3.10 / 488.91 | 5 | 66 |
4 | 13 | 1398.60 | 20 | 14.55 | 2483 | 723 | 3.82 / 489.64 | 5 | 78 |
5 | 13 | 1001.08 | 20 | 14.63 | 1906 | 558 | 4.38 / 490.19 | 5 | 86 |
6 | 13 | 15.88 | 20 | 15.00 | 382 | 115 | 4.49 / 490.31 | 5 | 63 |
7 | 8 | -0.04 | 216 | 14.95 | 338 | 1091 | 5.58 / 491.40 | 5 | 135 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 29 | 14.95 | 511 | 222 | 0.22 / 480.57 | 5 | 37 |
2 | 3 | 1028.12 | 1 | 15.04 | 1990 | 30 | 0.25 / 480.60 | 5 | 35 |
3 | 7 | 2009.24 | 40 | 14.51 | 3345 | 1941 | 2.19 / 482.54 | 35 | 64 |
4 | 13 | 1981.20 | 20 | 14.49 | 3266 | 946 | 3.14 / 483.49 | 5 | 66 |
5 | 13 | 1309.12 | 20 | 14.58 | 2294 | 669 | 3.81 / 484.16 | 5 | 80 |
6 | 13 | 725.16 | 20 | 14.74 | 1470 | 433 | 4.24 / 484.59 | 5 | 87 |
7 | 13 | 108.24 | 20 | 14.96 | 521 | 156 | 4.40 / 484.75 | 5 | 69 |
8 | 8 | 0.20 | 216 | 14.94 | 331 | 1068 | 5.47 / 485.82 | 5 | 130 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 29 | 14.91 | 504 | 218 | 0.22 / 474.98 | 5 | 42 |
2 | 7 | 2009.68 | 40 | 14.53 | 3316 | 1927 | 2.15 / 476.91 | 42 | 65 |
3 | 13 | 1979.60 | 20 | 14.50 | 3286 | 953 | 3.10 / 477.86 | 5 | 69 |
4 | 13 | 1431.08 | 20 | 14.56 | 2495 | 727 | 3.82 / 478.59 | 5 | 80 |
5 | 13 | 756.60 | 20 | 14.75 | 1530 | 451 | 4.28 / 479.04 | 5 | 89 |
6 | 13 | 327.76 | 20 | 14.90 | 862 | 257 | 4.53 / 479.29 | 5 | 76 |
7 | 8 | 0.12 | 216 | 14.97 | 327 | 1057 | 5.59 / 480.35 | 5 | 135 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 30 | 14.93 | 491 | 220 | 0.22 / 469.40 | 5 | 36 |
2 | 7 | 2003.48 | 40 | 14.52 | 3282 | 1906 | 2.13 / 471.30 | 36 | 67 |
3 | 13 | 1973.68 | 20 | 14.48 | 3253 | 942 | 3.07 / 472.25 | 5 | 72 |
4 | 13 | 1473.24 | 20 | 14.53 | 2554 | 742 | 3.81 / 472.99 | 5 | 83 |
5 | 13 | 797.64 | 20 | 14.69 | 1569 | 461 | 4.27 / 473.45 | 5 | 92 |
6 | 13 | 180.76 | 20 | 14.92 | 654 | 195 | 4.47 / 473.64 | 5 | 87 |
7 | 8 | -0.32 | 218 | 14.93 | 343 | 1116 | 5.58 / 474.76 | 5 | 133 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 30 | 14.91 | 512 | 229 | 0.23 / 463.69 | 5 | 35 |
2 | 7 | 2007.60 | 40 | 14.51 | 3316 | 1925 | 2.15 / 465.61 | 35 | 66 |
3 | 13 | 1976.32 | 20 | 14.48 | 3269 | 947 | 3.10 / 466.56 | 5 | 70 |
4 | 13 | 1442.08 | 20 | 14.53 | 2539 | 738 | 3.84 / 467.29 | 5 | 82 |
5 | 13 | 805.28 | 20 | 14.70 | 1588 | 467 | 4.31 / 467.76 | 5 | 90 |
6 | 13 | 258.00 | 20 | 14.91 | 770 | 230 | 4.53 / 467.99 | 5 | 75 |
7 | 13 | 191.88 | 20 | 14.92 | 656 | 196 | 4.73 / 468.19 | 5 | 70 |
8 | 8 | 0.12 | 201 | 14.94 | 330 | 991 | 5.72 / 469.18 | 5 | 135 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 30 | 14.95 | 516 | 231 | 0.23 / 458.06 | 5 | 34 |
2 | 7 | 2013.68 | 40 | 14.51 | 3341 | 1939 | 2.17 / 460.00 | 7 | 65 |
3 | 13 | 1985.16 | 20 | 14.48 | 3292 | 953 | 3.12 / 460.95 | 5 | 68 |
4 | 13 | 1330.32 | 20 | 14.56 | 2380 | 693 | 3.82 / 461.64 | 5 | 82 |
5 | 13 | 796.88 | 20 | 14.70 | 1609 | 473 | 4.29 / 462.12 | 5 | 91 |
6 | 13 | 248.80 | 20 | 14.90 | 754 | 225 | 4.51 / 462.34 | 5 | 69 |
7 | 8 | 0.08 | 220 | 14.93 | 340 | 1117 | 5.63 / 463.46 | 5 | 142 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 29 | 14.95 | 500 | 217 | 0.22 / 452.53 | 5 | 35 |
2 | 7 | 2009.52 | 41 | 14.52 | 3338 | 1987 | 2.20 / 454.52 | 10 | 64 |
3 | 13 | 1980.96 | 20 | 14.49 | 3302 | 957 | 3.16 / 455.47 | 5 | 66 |
4 | 13 | 1367.08 | 20 | 14.56 | 2429 | 707 | 3.87 / 456.18 | 5 | 81 |
5 | 13 | 816.80 | 20 | 14.71 | 1614 | 475 | 4.34 / 456.66 | 5 | 86 |
6 | 13 | 23.40 | 20 | 15.00 | 373 | 112 | 4.45 / 456.77 | 5 | 62 |
7 | 8 | 0.16 | 218 | 14.96 | 324 | 1057 | 5.51 / 457.83 | 5 | 135 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 30 | 14.94 | 491 | 220 | 0.22 / 447.01 | 5 | 33 |
2 | 3 | 963.00 | -1 | 15.37 | 0 | 0 | 0.00 / 447.01 | 5 | 33 |
3 | 7 | 2009.92 | 40 | 14.53 | 3322 | 1931 | 2.15 / 448.94 | 33 | 65 |
4 | 13 | 1981.92 | 20 | 14.50 | 3321 | 963 | 3.11 / 449.90 | 5 | 69 |
5 | 13 | 1381.60 | 20 | 14.56 | 2423 | 706 | 3.82 / 450.61 | 5 | 81 |
6 | 13 | 855.84 | 20 | 14.69 | 1698 | 499 | 4.32 / 451.10 | 5 | 88 |
7 | 13 | 36.68 | 20 | 15.00 | 412 | 124 | 4.44 / 451.23 | 5 | 63 |
8 | 8 | 0.00 | 216 | 14.96 | 336 | 1086 | 5.53 / 452.31 | 6 | 129 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 30 | 14.95 | 483 | 217 | 0.22 / 441.55 | 5 | 32 |
2 | 7 | 2009.48 | 41 | 14.52 | 3326 | 1980 | 2.20 / 443.53 | 32 | 66 |
3 | 13 | 1977.28 | 20 | 14.49 | 3280 | 951 | 3.15 / 444.48 | 5 | 69 |
4 | 13 | 1210.08 | 20 | 14.60 | 2204 | 644 | 3.79 / 445.12 | 5 | 84 |
5 | 13 | 698.28 | 20 | 14.75 | 1444 | 426 | 4.22 / 445.55 | 5 | 88 |
6 | 13 | 185.72 | 20 | 14.94 | 628 | 188 | 4.40 / 445.74 | 5 | 69 |
7 | 8 | 0.28 | 216 | 14.94 | 325 | 1049 | 5.45 / 446.79 | 5 | 135 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 30 | 14.95 | 497 | 223 | 0.22 / 435.98 | 5 | 29 |
2 | 7 | 2009.16 | 40 | 14.52 | 3335 | 1937 | 2.16 / 437.92 | 29 | 65 |
3 | 13 | 1976.88 | 20 | 14.49 | 3293 | 954 | 3.11 / 438.87 | 5 | 69 |
4 | 13 | 1388.04 | 20 | 14.55 | 2449 | 713 | 3.83 / 439.59 | 5 | 81 |
5 | 13 | 854.28 | 20 | 14.68 | 1696 | 498 | 4.32 / 440.09 | 5 | 90 |
6 | 13 | 150.32 | 20 | 14.95 | 581 | 174 | 4.50 / 440.26 | 5 | 66 |
7 | 8 | -0.04 | 221 | 14.95 | 325 | 1074 | 5.57 / 441.33 | 5 | 138 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 30 | 14.95 | 487 | 218 | 0.22 / 430.47 | 5 | 27 |
2 | 7 | 2005.72 | 40 | 14.52 | 3345 | 1943 | 2.16 / 432.42 | 27 | 64 |
3 | 13 | 1977.12 | 20 | 14.50 | 3280 | 951 | 3.11 / 433.37 | 5 | 66 |
4 | 13 | 1367.60 | 20 | 14.56 | 2431 | 708 | 3.82 / 434.07 | 5 | 79 |
5 | 13 | 734.20 | 20 | 14.75 | 1493 | 440 | 4.26 / 434.51 | 5 | 85 |
6 | 13 | 151.16 | 20 | 14.96 | 580 | 174 | 4.43 / 434.69 | 5 | 63 |
7 | 8 | 0.52 | 220 | 14.95 | 326 | 1072 | 5.51 / 435.76 | 5 | 149 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 30 | 14.97 | 491 | 221 | 0.22 / 424.89 | 5 | 26 |
2 | 7 | 2008.24 | 40 | 14.52 | 3352 | 1947 | 2.17 / 426.83 | 6 | 65 |
3 | 13 | 1981.76 | 20 | 14.50 | 3312 | 960 | 3.13 / 427.80 | 5 | 68 |
4 | 13 | 1274.36 | 20 | 14.59 | 2283 | 666 | 3.79 / 428.46 | 5 | 81 |
5 | 13 | 941.80 | 20 | 14.65 | 1811 | 531 | 4.32 / 428.99 | 5 | 87 |
6 | 13 | 163.08 | 20 | 14.96 | 601 | 180 | 4.50 / 429.17 | 5 | 61 |
7 | 8 | 0.08 | 220 | 14.95 | 329 | 1082 | 5.59 / 430.25 | 5 | 135 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 29 | 14.99 | 481 | 209 | 0.21 / 419.24 | 5 | 24 |
2 | 3 | 1023.84 | 1 | 15.08 | 1988 | 30 | 0.24 / 419.27 | 5 | 25 |
3 | 7 | 2010.24 | 41 | 14.53 | 3333 | 1986 | 2.22 / 421.25 | 25 | 66 |
4 | 13 | 1979.44 | 20 | 14.50 | 3284 | 952 | 3.18 / 422.20 | 5 | 68 |
5 | 13 | 1604.00 | 20 | 14.50 | 2773 | 804 | 3.98 / 423.01 | 5 | 78 |
6 | 13 | 714.52 | 20 | 14.75 | 1469 | 433 | 4.41 / 423.44 | 5 | 87 |
7 | 13 | 115.52 | 20 | 14.98 | 533 | 160 | 4.57 / 423.60 | 5 | 61 |
8 | 8 | 0.08 | 220 | 14.97 | 324 | 1067 | 5.64 / 424.67 | 5 | 141 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 29 | 15.00 | 486 | 211 | 0.21 / 413.71 | 5 | 24 |
2 | 3 | 1023.76 | 1 | 15.08 | 2012 | 30 | 0.24 / 413.74 | 5 | 23 |
3 | 7 | 2013.92 | 40 | 14.54 | 3337 | 1941 | 2.18 / 415.68 | 23 | 66 |
4 | 13 | 1985.84 | 20 | 14.51 | 3309 | 960 | 3.14 / 416.64 | 5 | 69 |
5 | 13 | 1333.32 | 20 | 14.58 | 2365 | 690 | 3.83 / 417.33 | 5 | 81 |
6 | 13 | 807.36 | 20 | 14.71 | 1614 | 475 | 4.31 / 417.81 | 5 | 90 |
7 | 13 | 127.08 | 20 | 14.98 | 538 | 161 | 4.47 / 417.97 | 5 | 62 |
8 | 13 | 25.12 | 20 | 15.01 | 366 | 110 | 4.58 / 418.08 | 5 | 60 |
9 | 8 | 0.08 | 199 | 14.97 | 317 | 944 | 5.52 / 419.02 | 5 | 132 |
10 | 14 | 0.12 | 1 | 14.94 | 317 | 5 | 5.53 / 419.03 | 54 | 101 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 28 | 14.96 | 524 | 219 | 0.22 / 408.15 | 5 | 32 |
2 | 7 | 2012.88 | 40 | 14.55 | 3323 | 1934 | 2.15 / 410.09 | 32 | 66 |
3 | 13 | 1981.64 | 20 | 14.52 | 3331 | 967 | 3.12 / 411.06 | 5 | 70 |
4 | 13 | 1447.20 | 20 | 14.57 | 2545 | 742 | 3.86 / 411.80 | 5 | 82 |
5 | 13 | 750.20 | 20 | 14.76 | 1532 | 452 | 4.31 / 412.25 | 5 | 92 |
6 | 13 | 201.84 | 20 | 14.97 | 659 | 197 | 4.51 / 412.45 | 5 | 71 |
7 | 8 | 0.08 | 218 | 14.99 | 322 | 1052 | 5.56 / 413.50 | 5 | 131 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 28 | 14.96 | 513 | 215 | 0.21 / 402.63 | 5 | 35 |
2 | 7 | 2010.80 | 40 | 14.54 | 3326 | 1934 | 2.15 / 404.56 | 35 | 69 |
3 | 13 | 1979.04 | 20 | 14.51 | 3294 | 956 | 3.11 / 405.52 | 5 | 73 |
4 | 13 | 1504.08 | 20 | 14.55 | 2616 | 761 | 3.87 / 406.28 | 5 | 83 |
5 | 13 | 643.68 | 20 | 14.79 | 1358 | 402 | 4.27 / 406.68 | 5 | 93 |
6 | 13 | 53.64 | 20 | 15.01 | 460 | 138 | 4.41 / 406.82 | 5 | 86 |
7 | 8 | -0.08 | 212 | 14.97 | 351 | 1114 | 5.52 / 407.93 | 5 | 133 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 29 | 14.94 | 498 | 216 | 0.22 / 397.01 | 5 | 30 |
2 | 7 | 2011.56 | 40 | 14.54 | 3328 | 1936 | 2.15 / 398.94 | 30 | 69 |
3 | 13 | 1981.76 | 20 | 14.51 | 3323 | 964 | 3.12 / 399.91 | 5 | 72 |
4 | 13 | 1456.84 | 20 | 14.56 | 2570 | 748 | 3.86 / 400.66 | 5 | 85 |
5 | 13 | 855.72 | 20 | 14.71 | 1654 | 487 | 4.35 / 401.14 | 5 | 92 |
6 | 13 | 62.52 | 20 | 15.00 | 467 | 140 | 4.49 / 401.28 | 5 | 88 |
7 | 8 | 0.32 | 216 | 14.97 | 350 | 1132 | 5.62 / 402.41 | 5 | 133 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 29 | 14.97 | 499 | 217 | 0.22 / 391.45 | 5 | 25 |
2 | 7 | 2009.92 | 40 | 14.53 | 3316 | 1927 | 2.14 / 393.38 | 25 | 69 |
3 | 13 | 1980.56 | 20 | 14.51 | 3295 | 956 | 3.10 / 394.33 | 5 | 73 |
4 | 13 | 1420.84 | 20 | 14.55 | 2523 | 734 | 3.83 / 395.07 | 5 | 84 |
5 | 13 | 743.16 | 20 | 14.73 | 1486 | 438 | 4.27 / 395.50 | 5 | 93 |
6 | 13 | 71.24 | 20 | 14.98 | 488 | 146 | 4.42 / 395.65 | 5 | 88 |
7 | 8 | -0.08 | 218 | 14.95 | 350 | 1141 | 5.56 / 396.79 | 5 | 132 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 29 | 14.95 | 498 | 216 | 0.22 / 385.85 | 5 | 24 |
2 | 7 | 2007.60 | 40 | 14.55 | 3324 | 1935 | 2.15 / 387.79 | 24 | 68 |
3 | 13 | 1975.60 | 20 | 14.50 | 3306 | 959 | 3.11 / 388.75 | 5 | 71 |
4 | 13 | 1448.32 | 20 | 14.56 | 2531 | 737 | 3.85 / 389.48 | 5 | 82 |
5 | 13 | 861.80 | 20 | 14.70 | 1670 | 491 | 4.34 / 389.97 | 5 | 90 |
6 | 13 | 72.16 | 20 | 15.00 | 466 | 140 | 4.48 / 390.11 | 5 | 73 |
7 | 8 | 0.04 | 220 | 14.97 | 340 | 1120 | 5.60 / 391.23 | 5 | 140 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 29 | 14.98 | 465 | 202 | 0.20 / 380.29 | 5 | 20 |
2 | 7 | 2010.12 | 40 | 14.53 | 3340 | 1941 | 2.14 / 382.23 | 20 | 68 |
3 | 13 | 1981.08 | 20 | 14.50 | 3302 | 958 | 3.10 / 383.19 | 5 | 72 |
4 | 13 | 1272.92 | 20 | 14.60 | 2289 | 668 | 3.77 / 383.86 | 5 | 84 |
5 | 13 | 770.44 | 20 | 14.72 | 1563 | 460 | 4.23 / 384.32 | 5 | 92 |
6 | 13 | 180.60 | 20 | 14.94 | 655 | 196 | 4.43 / 384.52 | 5 | 78 |
7 | 8 | 0.00 | 221 | 14.95 | 339 | 1120 | 5.55 / 385.64 | 5 | 151 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 30 | 14.96 | 492 | 221 | 0.22 / 374.91 | 5 | 22 |
2 | 7 | 2009.12 | 40 | 14.55 | 3344 | 1946 | 2.17 / 376.86 | 22 | 66 |
3 | 13 | 1978.96 | 20 | 14.52 | 3307 | 960 | 3.13 / 377.82 | 5 | 69 |
4 | 13 | 1261.96 | 20 | 14.62 | 2272 | 664 | 3.79 / 378.49 | 5 | 84 |
5 | 13 | 635.36 | 20 | 14.79 | 1354 | 401 | 4.19 / 378.89 | 5 | 88 |
6 | 13 | 88.24 | 20 | 14.99 | 489 | 147 | 4.34 / 379.03 | 5 | 68 |
7 | 8 | 0.04 | 218 | 14.98 | 324 | 1058 | 5.40 / 380.09 | 5 | 138 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 30 | 14.98 | 488 | 219 | 0.22 / 369.39 | 5 | 22 |
2 | 7 | 2004.60 | 41 | 14.54 | 3323 | 1981 | 2.20 / 371.38 | 22 | 68 |
3 | 13 | 1976.40 | 20 | 14.51 | 3311 | 961 | 3.16 / 372.34 | 5 | 71 |
4 | 13 | 1238.92 | 20 | 14.62 | 2225 | 651 | 3.81 / 372.99 | 5 | 84 |
5 | 13 | 782.80 | 20 | 14.73 | 1564 | 461 | 4.27 / 373.45 | 5 | 90 |
6 | 13 | 44.44 | 20 | 15.00 | 425 | 127 | 4.40 / 373.58 | 5 | 73 |
7 | 8 | -0.04 | 218 | 14.96 | 343 | 1119 | 5.52 / 374.69 | 5 | 134 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 29 | 14.99 | 497 | 216 | 0.22 / 363.85 | 5 | 22 |
2 | 7 | 2010.72 | 40 | 14.56 | 3335 | 1942 | 2.16 / 365.79 | 22 | 66 |
3 | 13 | 1984.24 | 20 | 14.53 | 3286 | 955 | 3.11 / 366.75 | 5 | 69 |
4 | 13 | 1470.84 | 20 | 14.57 | 2564 | 747 | 3.86 / 367.50 | 5 | 81 |
5 | 13 | 790.68 | 20 | 14.74 | 1596 | 471 | 4.33 / 367.97 | 5 | 89 |
6 | 13 | 48.60 | 20 | 15.01 | 427 | 128 | 4.46 / 368.09 | 5 | 65 |
7 | 8 | 0.12 | 218 | 14.98 | 331 | 1081 | 5.54 / 369.18 | 5 | 130 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 29 | 14.99 | 492 | 214 | 0.21 / 358.29 | 5 | 21 |
2 | 7 | 2014.24 | 40 | 14.55 | 3359 | 1955 | 2.17 / 360.25 | 9 | 68 |
3 | 13 | 1984.04 | 20 | 14.51 | 3328 | 966 | 3.13 / 361.21 | 5 | 71 |
4 | 13 | 1332.24 | 20 | 14.60 | 2378 | 694 | 3.83 / 361.91 | 5 | 83 |
5 | 13 | 873.16 | 20 | 14.71 | 1716 | 505 | 4.33 / 362.41 | 5 | 91 |
6 | 13 | 43.28 | 20 | 15.03 | 422 | 127 | 4.46 / 362.54 | 5 | 64 |
7 | 8 | 0.04 | 220 | 14.99 | 332 | 1095 | 5.56 / 363.64 | 5 | 140 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 29 | 15.00 | 477 | 207 | 0.21 / 352.63 | 5 | 21 |
2 | 7 | 2005.68 | 40 | 14.56 | 3335 | 1942 | 2.15 / 354.57 | 21 | 68 |
3 | 13 | 1977.48 | 20 | 14.52 | 3325 | 966 | 3.12 / 355.54 | 5 | 72 |
4 | 13 | 1435.40 | 20 | 14.58 | 2515 | 733 | 3.85 / 356.27 | 5 | 82 |
5 | 13 | 872.52 | 20 | 14.72 | 1706 | 502 | 4.35 / 356.77 | 5 | 91 |
6 | 13 | 206.36 | 20 | 14.97 | 678 | 203 | 4.55 / 356.98 | 5 | 68 |
7 | 13 | 19.32 | 20 | 15.03 | 368 | 111 | 4.66 / 357.09 | 5 | 65 |
8 | 8 | 0.16 | 201 | 14.99 | 330 | 994 | 5.66 / 358.08 | 5 | 136 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 29 | 14.99 | 494 | 215 | 0.21 / 347.19 | 5 | 23 |
2 | 7 | 2003.40 | 40 | 14.57 | 3334 | 1943 | 2.16 / 349.13 | 23 | 69 |
3 | 13 | 1972.60 | 20 | 14.54 | 3297 | 959 | 3.12 / 350.09 | 5 | 72 |
4 | 13 | 1238.40 | 20 | 14.65 | 2215 | 649 | 3.77 / 350.74 | 5 | 85 |
5 | 13 | 789.92 | 20 | 14.75 | 1592 | 470 | 4.24 / 351.21 | 5 | 94 |
6 | 13 | 85.60 | 20 | 15.03 | 482 | 145 | 4.38 / 351.35 | 5 | 68 |
7 | 8 | 0.04 | 216 | 15.01 | 329 | 1067 | 5.45 / 352.42 | 5 | 135 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 29 | 15.03 | 477 | 208 | 0.21 / 341.52 | 5 | 23 |
2 | 7 | 2003.20 | 40 | 14.56 | 3323 | 1935 | 2.14 / 343.45 | 11 | 70 |
3 | 13 | 1973.28 | 20 | 14.53 | 3278 | 953 | 3.10 / 344.41 | 5 | 72 |
4 | 13 | 1577.20 | 20 | 14.54 | 2748 | 799 | 3.89 / 345.21 | 5 | 82 |
5 | 13 | 791.92 | 20 | 14.75 | 1578 | 466 | 4.36 / 345.67 | 5 | 92 |
6 | 13 | 179.28 | 20 | 14.98 | 642 | 192 | 4.55 / 345.86 | 5 | 75 |
7 | 8 | 0.08 | 220 | 14.99 | 337 | 1111 | 5.66 / 346.97 | 5 | 137 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 28 | 14.99 | 520 | 218 | 0.22 / 335.99 | 5 | 36 |
2 | 3 | 1019.28 | 1 | 15.06 | 1997 | 30 | 0.25 / 336.02 | 5 | 19 |
3 | 7 | 2011.48 | 40 | 14.57 | 3351 | 1953 | 2.20 / 337.97 | 19 | 70 |
4 | 13 | 1911.52 | 20 | 14.56 | 3195 | 930 | 3.13 / 338.90 | 5 | 73 |
5 | 13 | 1362.44 | 20 | 14.63 | 2414 | 706 | 3.84 / 339.61 | 5 | 85 |
6 | 13 | 801.16 | 20 | 14.78 | 1606 | 475 | 4.31 / 340.08 | 5 | 95 |
7 | 13 | 105.40 | 20 | 15.05 | 522 | 157 | 4.47 / 340.24 | 5 | 69 |
8 | 8 | 0.20 | 218 | 15.03 | 326 | 1068 | 5.54 / 341.31 | 5 | 139 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 29 | 14.97 | 527 | 229 | 0.23 / 330.45 | 5 | 47 |
2 | 7 | 2007.56 | 40 | 14.56 | 3326 | 1937 | 2.17 / 332.38 | 47 | 70 |
3 | 13 | 1981.32 | 20 | 14.54 | 3275 | 952 | 3.12 / 333.34 | 5 | 74 |
4 | 13 | 1461.88 | 20 | 14.59 | 2546 | 743 | 3.86 / 334.08 | 5 | 85 |
5 | 13 | 705.72 | 20 | 14.81 | 1424 | 422 | 4.28 / 334.50 | 5 | 93 |
6 | 13 | 55.40 | 20 | 15.04 | 459 | 138 | 4.42 / 334.64 | 5 | 88 |
7 | 8 | 0.12 | 214 | 15.00 | 353 | 1133 | 5.55 / 335.77 | 5 | 130 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 30 | 15.00 | 488 | 220 | 0.22 / 324.85 | 5 | 26 |
2 | 7 | 2007.76 | 41 | 14.55 | 3318 | 1979 | 2.20 / 326.83 | 26 | 70 |
3 | 13 | 1980.28 | 20 | 14.53 | 3278 | 953 | 3.15 / 327.79 | 5 | 73 |
4 | 13 | 1328.04 | 20 | 14.62 | 2376 | 695 | 3.85 / 328.48 | 5 | 87 |
5 | 13 | 627.92 | 20 | 14.83 | 1324 | 393 | 4.24 / 328.87 | 5 | 93 |
6 | 13 | 205.60 | 20 | 14.97 | 706 | 211 | 4.45 / 329.09 | 5 | 91 |
7 | 8 | 0.08 | 214 | 14.99 | 353 | 1132 | 5.58 / 330.22 | 5 | 129 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 30 | 15.00 | 502 | 226 | 0.23 / 319.28 | 5 | 36 |
2 | 7 | 2007.32 | 40 | 14.57 | 3333 | 1942 | 2.17 / 321.23 | 36 | 68 |
3 | 13 | 1975.80 | 20 | 14.54 | 3294 | 958 | 3.13 / 322.18 | 5 | 70 |
4 | 13 | 1458.12 | 20 | 14.59 | 2542 | 742 | 3.87 / 322.93 | 5 | 82 |
5 | 13 | 771.24 | 20 | 14.77 | 1557 | 460 | 4.33 / 323.39 | 5 | 92 |
6 | 13 | 72.92 | 20 | 15.03 | 466 | 140 | 4.47 / 323.53 | 5 | 69 |
7 | 8 | 0.12 | 218 | 15.00 | 339 | 1109 | 5.58 / 324.64 | 5 | 136 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 30 | 15.01 | 499 | 225 | 0.22 / 313.83 | 5 | 36 |
2 | 7 | 2003.84 | 40 | 14.58 | 3338 | 1947 | 2.17 / 315.77 | 36 | 67 |
3 | 13 | 1801.36 | 20 | 14.58 | 3070 | 895 | 3.07 / 316.67 | 5 | 73 |
4 | 13 | 1303.60 | 20 | 14.63 | 2350 | 688 | 3.75 / 317.36 | 5 | 83 |
5 | 13 | 809.64 | 20 | 14.77 | 1625 | 480 | 4.23 / 317.84 | 5 | 90 |
6 | 8 | 0.08 | 238 | 15.01 | 342 | 1222 | 5.46 / 319.06 | 5 | 140 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 29 | 15.01 | 502 | 219 | 0.22 / 308.25 | 5 | 36 |
2 | 7 | 2012.56 | 41 | 14.58 | 3340 | 1997 | 2.22 / 310.25 | 36 | 66 |
3 | 13 | 1984.20 | 20 | 14.55 | 3303 | 961 | 3.18 / 311.21 | 5 | 69 |
4 | 13 | 1369.28 | 20 | 14.62 | 2448 | 716 | 3.89 / 311.92 | 5 | 83 |
5 | 13 | 739.56 | 20 | 14.82 | 1525 | 452 | 4.34 / 312.38 | 5 | 87 |
6 | 8 | 0.20 | 238 | 15.03 | 343 | 1227 | 5.57 / 313.60 | 5 | 133 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 29 | 15.03 | 501 | 218 | 0.22 / 302.65 | 5 | 37 |
2 | 7 | 2009.68 | 40 | 14.59 | 3341 | 1950 | 2.17 / 304.60 | 37 | 67 |
3 | 13 | 1979.52 | 20 | 14.56 | 3294 | 959 | 3.13 / 305.56 | 5 | 70 |
4 | 13 | 1353.88 | 20 | 14.64 | 2397 | 702 | 3.83 / 306.26 | 5 | 83 |
5 | 13 | 825.68 | 20 | 14.78 | 1652 | 488 | 4.32 / 306.75 | 5 | 91 |
6 | 13 | 145.88 | 20 | 15.03 | 588 | 177 | 4.49 / 306.93 | 5 | 68 |
7 | 8 | 0.04 | 218 | 15.03 | 337 | 1104 | 5.60 / 308.03 | 5 | 138 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 30 | 15.03 | 514 | 232 | 0.23 / 297.00 | 5 | 37 |
2 | 7 | 2017.48 | 40 | 14.58 | 3367 | 1964 | 2.20 / 298.97 | 37 | 68 |
3 | 13 | 1994.32 | 20 | 14.54 | 3320 | 965 | 3.16 / 299.93 | 5 | 71 |
4 | 13 | 1425.88 | 20 | 14.62 | 2523 | 738 | 3.90 / 300.67 | 5 | 83 |
5 | 13 | 835.32 | 20 | 14.78 | 1666 | 492 | 4.39 / 301.16 | 5 | 91 |
6 | 13 | 121.48 | 20 | 15.05 | 554 | 167 | 4.56 / 301.33 | 5 | 67 |
7 | 8 | 0.16 | 218 | 15.04 | 337 | 1105 | 5.66 / 302.43 | 5 | 140 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 29 | 15.05 | 501 | 219 | 0.22 / 291.48 | 5 | 38 |
2 | 3 | 1027.48 | 1 | 15.13 | 1967 | 30 | 0.25 / 291.51 | 5 | 33 |
3 | 7 | 2009.84 | 40 | 14.59 | 3338 | 1948 | 2.20 / 293.45 | 33 | 68 |
4 | 13 | 1981.96 | 20 | 14.56 | 3311 | 964 | 3.16 / 294.42 | 5 | 72 |
5 | 13 | 1314.92 | 20 | 14.65 | 2353 | 689 | 3.85 / 295.11 | 5 | 85 |
6 | 13 | 729.36 | 20 | 14.83 | 1498 | 444 | 4.29 / 295.55 | 5 | 90 |
7 | 8 | 0.20 | 238 | 15.05 | 340 | 1218 | 5.51 / 296.77 | 5 | 140 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 28 | 15.07 | 498 | 210 | 0.21 / 286.02 | 5 | 36 |
2 | 3 | 1018.92 | 1 | 15.14 | 1987 | 30 | 0.24 / 286.05 | 5 | 15 |
3 | 7 | 2010.84 | 40 | 14.60 | 3341 | 1951 | 2.19 / 288.01 | 15 | 66 |
4 | 13 | 1838.84 | 20 | 14.60 | 3105 | 907 | 3.10 / 288.91 | 5 | 72 |
5 | 13 | 1343.12 | 20 | 14.65 | 2406 | 705 | 3.80 / 289.62 | 5 | 84 |
6 | 13 | 712.96 | 20 | 14.86 | 1470 | 437 | 4.24 / 290.05 | 5 | 85 |
7 | 8 | -0.16 | 238 | 15.06 | 336 | 1204 | 5.44 / 291.26 | 5 | 136 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 28 | 15.07 | 508 | 214 | 0.21 / 280.46 | 5 | 38 |
2 | 7 | 2004.68 | 40 | 14.61 | 3318 | 1939 | 2.15 / 282.39 | 38 | 69 |
3 | 13 | 1978.48 | 20 | 14.58 | 3278 | 956 | 3.11 / 283.35 | 5 | 71 |
4 | 13 | 1465.28 | 20 | 14.64 | 2565 | 751 | 3.86 / 284.10 | 5 | 83 |
5 | 13 | 777.80 | 20 | 14.85 | 1573 | 467 | 4.33 / 284.57 | 5 | 92 |
6 | 13 | 77.88 | 20 | 15.11 | 471 | 142 | 4.47 / 284.71 | 5 | 68 |
7 | 8 | 0.00 | 219 | 15.08 | 334 | 1103 | 5.57 / 285.81 | 5 | 140 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 28 | 15.06 | 497 | 210 | 0.21 / 274.99 | 5 | 39 |
2 | 7 | 2007.60 | 40 | 14.60 | 3321 | 1939 | 2.15 / 276.92 | 39 | 70 |
3 | 13 | 1976.32 | 20 | 14.58 | 3283 | 957 | 3.11 / 277.88 | 5 | 73 |
4 | 13 | 1315.12 | 20 | 14.69 | 2345 | 689 | 3.80 / 278.57 | 5 | 86 |
5 | 13 | 773.60 | 20 | 14.84 | 1540 | 457 | 4.25 / 279.03 | 5 | 93 |
6 | 8 | 0.00 | 235 | 15.09 | 342 | 1213 | 5.47 / 280.24 | 5 | 131 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 29 | 15.08 | 503 | 220 | 0.22 / 269.38 | 5 | 37 |
2 | 7 | 2015.92 | 40 | 14.59 | 3338 | 1948 | 2.17 / 271.33 | 37 | 70 |
3 | 13 | 1992.04 | 20 | 14.57 | 3314 | 966 | 3.13 / 272.30 | 5 | 74 |
4 | 13 | 1508.28 | 20 | 14.64 | 2627 | 769 | 3.90 / 273.07 | 5 | 84 |
5 | 13 | 760.80 | 20 | 14.85 | 1521 | 452 | 4.35 / 273.52 | 5 | 94 |
6 | 13 | 75.64 | 20 | 15.11 | 479 | 145 | 4.50 / 273.66 | 5 | 85 |
7 | 8 | 0.00 | 212 | 15.08 | 348 | 1113 | 5.61 / 274.78 | 5 | 131 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 28 | 15.10 | 497 | 210 | 0.21 / 263.83 | 5 | 32 |
2 | 7 | 2009.00 | 40 | 14.61 | 3310 | 1934 | 2.14 / 265.76 | 32 | 71 |
3 | 13 | 1976.72 | 20 | 14.58 | 3279 | 956 | 3.10 / 266.72 | 5 | 74 |
4 | 13 | 1565.56 | 20 | 14.62 | 2710 | 792 | 3.89 / 267.51 | 5 | 84 |
5 | 13 | 726.88 | 20 | 14.87 | 1475 | 439 | 4.33 / 267.95 | 5 | 93 |
6 | 8 | 0.12 | 238 | 15.10 | 338 | 1215 | 5.55 / 269.16 | 5 | 135 |
Average= | 5.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 28 | 15.05 | 532 | 224 | 0.22 / 258.17 | 5 | 53 |
2 | 7 | 2003.88 | 41 | 14.61 | 3310 | 1983 | 2.21 / 260.15 | 5 | 70 |
3 | 13 | 1976.16 | 20 | 14.59 | 3275 | 956 | 3.16 / 261.11 | 5 | 73 |
4 | 13 | 1332.80 | 20 | 14.72 | 2358 | 694 | 3.86 / 261.80 | 5 | 86 |
5 | 13 | 939.96 | 20 | 14.81 | 1789 | 530 | 4.39 / 262.33 | 5 | 93 |
6 | 13 | 195.16 | 20 | 15.10 | 657 | 198 | 4.59 / 262.53 | 5 | 75 |
7 | 8 | 0.20 | 218 | 15.11 | 330 | 1087 | 5.67 / 263.62 | 5 | 138 |
Average= | 5.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 29 | 15.10 | 489 | 214 | 0.21 / 252.58 | 5 | 31 |
2 | 7 | 2007.28 | 40 | 14.59 | 3326 | 1941 | 2.16 / 254.52 | 31 | 72 |
3 | 13 | 1978.72 | 20 | 14.57 | 3283 | 957 | 3.11 / 255.48 | 5 | 76 |
4 | 13 | 1388.72 | 20 | 14.68 | 2465 | 724 | 3.84 / 256.20 | 5 | 87 |
5 | 13 | 576.80 | 20 | 14.93 | 1251 | 374 | 4.21 / 256.58 | 5 | 96 |
6 | 13 | 58.00 | 20 | 15.12 | 474 | 143 | 4.35 / 256.72 | 5 | 93 |
7 | 8 | 0.28 | 226 | 15.07 | 360 | 1226 | 5.58 / 257.95 | 5 | 130 |
Average= | 5.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 28 | 15.11 | 486 | 206 | 0.21 / 246.99 | 5 | 30 |
2 | 3 | 1024.48 | 1 | 15.17 | 1974 | 30 | 0.24 / 247.02 | 5 | 29 |
3 | 7 | 2004.76 | 40 | 14.61 | 3317 | 1938 | 2.17 / 248.96 | 29 | 69 |
4 | 13 | 1972.56 | 20 | 14.58 | 3286 | 958 | 3.13 / 249.92 | 5 | 73 |
5 | 13 | 1300.48 | 20 | 14.69 | 2324 | 683 | 3.82 / 250.60 | 5 | 87 |
6 | 13 | 809.16 | 20 | 14.83 | 1619 | 480 | 4.30 / 251.08 | 5 | 94 |
7 | 13 | 110.72 | 20 | 15.10 | 534 | 161 | 4.46 / 251.24 | 5 | 70 |
8 | 13 | 42.48 | 20 | 15.12 | 411 | 124 | 4.58 / 251.37 | 5 | 67 |
9 | 8 | 0.04 | 197 | 15.08 | 331 | 983 | 5.56 / 252.35 | 5 | 131 |
10 | 14 | -0.24 | 3 | 15.05 | 326 | 15 | 5.58 / 252.37 | 46 | 113 |
Average= | 5.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 28 | 15.12 | 487 | 206 | 0.21 / 241.50 | 5 | 32 |
2 | 7 | 2005.08 | 40 | 14.63 | 3345 | 1957 | 2.16 / 243.46 | 15 | 69 |
3 | 13 | 1979.72 | 20 | 14.60 | 3327 | 971 | 3.14 / 244.43 | 5 | 73 |
4 | 13 | 1409.44 | 20 | 14.68 | 2470 | 725 | 3.86 / 245.15 | 5 | 83 |
5 | 13 | 637.96 | 20 | 14.95 | 1353 | 405 | 4.26 / 245.56 | 5 | 87 |
6 | 13 | 59.28 | 20 | 15.16 | 440 | 133 | 4.40 / 245.69 | 5 | 65 |
7 | 8 | 0.24 | 217 | 15.12 | 334 | 1096 | 5.49 / 246.79 | 5 | 131 |
Average= | 5.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 28 | 15.14 | 477 | 202 | 0.20 / 235.89 | 5 | 28 |
2 | 7 | 2005.84 | 41 | 14.63 | 3318 | 1990 | 2.19 / 237.88 | 28 | 70 |
3 | 13 | 1974.36 | 20 | 14.62 | 3286 | 961 | 3.15 / 238.84 | 5 | 73 |
4 | 13 | 1251.20 | 20 | 14.76 | 2260 | 667 | 3.82 / 239.50 | 5 | 88 |
5 | 13 | 841.92 | 20 | 14.87 | 1660 | 494 | 4.31 / 240.00 | 5 | 95 |
6 | 13 | 175.24 | 20 | 15.13 | 626 | 189 | 4.50 / 240.19 | 5 | 73 |
7 | 13 | 26.48 | 20 | 15.17 | 377 | 114 | 4.62 / 240.30 | 5 | 68 |
8 | 8 | 0.64 | 195 | 15.13 | 328 | 968 | 5.59 / 241.27 | 5 | 131 |
9 | 14 | -0.32 | 5 | 15.10 | 331 | 25 | 5.61 / 241.29 | 45 | 136 |
Average= | 5.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 28 | 15.14 | 496 | 210 | 0.21 / 230.40 | 5 | 28 |
2 | 7 | 2010.92 | 40 | 14.62 | 3332 | 1949 | 2.16 / 232.35 | 28 | 72 |
3 | 13 | 1978.72 | 20 | 14.61 | 3284 | 960 | 3.12 / 233.31 | 5 | 75 |
4 | 13 | 1254.16 | 20 | 14.76 | 2273 | 671 | 3.79 / 233.98 | 5 | 90 |
5 | 13 | 727.84 | 20 | 14.92 | 1474 | 440 | 4.23 / 234.42 | 5 | 95 |
6 | 13 | 134.60 | 20 | 15.15 | 574 | 174 | 4.40 / 234.59 | 5 | 76 |
7 | 8 | 0.12 | 216 | 15.14 | 333 | 1089 | 5.49 / 235.68 | 5 | 135 |
Average= | 5.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 28 | 15.09 | 527 | 223 | 0.22 / 224.86 | 5 | 53 |
2 | 7 | 2010.52 | 40 | 14.64 | 3324 | 1947 | 2.17 / 226.81 | 5 | 73 |
3 | 13 | 1877.00 | 20 | 14.64 | 3168 | 928 | 3.10 / 227.73 | 5 | 78 |
4 | 13 | 1487.12 | 20 | 14.70 | 2606 | 766 | 3.86 / 228.50 | 5 | 87 |
5 | 13 | 688.60 | 20 | 14.94 | 1410 | 421 | 4.28 / 228.92 | 5 | 96 |
6 | 13 | 120.68 | 20 | 15.16 | 553 | 168 | 4.45 / 229.09 | 5 | 82 |
7 | 8 | 0.12 | 216 | 15.15 | 337 | 1103 | 5.55 / 230.19 | 5 | 135 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 28 | 15.11 | 532 | 225 | 0.23 / 219.24 | 5 | 36 |
2 | 7 | 2009.60 | 40 | 14.62 | 3330 | 1947 | 2.17 / 221.18 | 36 | 74 |
3 | 13 | 1837.08 | 20 | 14.64 | 3115 | 912 | 3.08 / 222.10 | 5 | 80 |
4 | 13 | 1449.72 | 20 | 14.70 | 2573 | 756 | 3.84 / 222.85 | 5 | 89 |
5 | 13 | 532.48 | 20 | 14.99 | 1183 | 355 | 4.20 / 223.21 | 5 | 98 |
6 | 13 | 79.28 | 20 | 15.15 | 516 | 156 | 4.35 / 223.36 | 5 | 94 |
7 | 8 | 0.20 | 229 | 15.11 | 368 | 1273 | 5.63 / 224.64 | 5 | 136 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 28 | 15.10 | 535 | 226 | 0.23 / 213.60 | 5 | 49 |
2 | 7 | 2010.16 | 40 | 14.63 | 3334 | 1951 | 2.18 / 215.55 | 49 | 74 |
3 | 13 | 1979.84 | 20 | 14.62 | 3300 | 965 | 3.14 / 216.51 | 5 | 77 |
4 | 13 | 1283.80 | 20 | 14.77 | 2315 | 684 | 3.83 / 217.20 | 5 | 92 |
5 | 13 | 650.32 | 20 | 14.96 | 1367 | 409 | 4.24 / 217.61 | 5 | 98 |
6 | 13 | 98.12 | 20 | 15.14 | 554 | 168 | 4.40 / 217.77 | 5 | 96 |
7 | 8 | -0.16 | 220 | 15.12 | 372 | 1237 | 5.64 / 219.01 | 5 | 137 |
Average= | 5.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 28 | 15.10 | 533 | 225 | 0.23 / 207.76 | 5 | 49 |
2 | 7 | 2010.56 | 41 | 14.64 | 3332 | 2000 | 2.23 / 209.76 | 49 | 74 |
3 | 13 | 1982.12 | 20 | 14.63 | 3277 | 959 | 3.18 / 210.72 | 5 | 78 |
4 | 13 | 1323.04 | 20 | 14.76 | 2377 | 702 | 3.89 / 211.42 | 5 | 92 |
5 | 13 | 934.36 | 20 | 14.86 | 1780 | 529 | 4.41 / 211.95 | 5 | 98 |
6 | 13 | 85.08 | 20 | 15.15 | 515 | 156 | 4.57 / 212.10 | 5 | 97 |
7 | 8 | 0.04 | 231 | 15.12 | 363 | 1268 | 5.84 / 213.37 | 5 | 132 |
Average= | 5.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 28 | 15.12 | 526 | 223 | 0.22 / 202.08 | 5 | 45 |
2 | 7 | 2003.84 | 40 | 14.64 | 3327 | 1948 | 2.17 / 204.03 | 45 | 75 |
3 | 13 | 1973.48 | 20 | 14.63 | 3276 | 959 | 3.13 / 204.99 | 5 | 78 |
4 | 13 | 1296.16 | 20 | 14.78 | 2321 | 686 | 3.82 / 205.67 | 5 | 93 |
5 | 13 | 535.08 | 20 | 15.00 | 1198 | 359 | 4.18 / 206.03 | 5 | 99 |
6 | 13 | 154.84 | 20 | 15.13 | 631 | 191 | 4.37 / 206.22 | 5 | 98 |
7 | 8 | 0.08 | 235 | 15.12 | 368 | 1308 | 5.67 / 207.53 | 5 | 132 |
Average= | 5.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 28 | 15.14 | 513 | 217 | 0.22 / 196.59 | 5 | 38 |
2 | 7 | 2006.96 | 40 | 14.64 | 3317 | 1942 | 2.16 / 198.53 | 38 | 75 |
3 | 13 | 1796.76 | 20 | 14.67 | 3054 | 896 | 3.06 / 199.43 | 5 | 82 |
4 | 13 | 1212.60 | 20 | 14.80 | 2219 | 657 | 3.71 / 200.08 | 5 | 94 |
5 | 13 | 580.08 | 20 | 14.99 | 1250 | 375 | 4.09 / 200.46 | 5 | 98 |
6 | 13 | 25.08 | 20 | 15.18 | 430 | 131 | 4.22 / 200.59 | 5 | 96 |
7 | 8 | 0.04 | 227 | 15.13 | 370 | 1271 | 5.49 / 201.86 | 5 | 130 |
Average= | 5.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 28 | 15.14 | 515 | 218 | 0.22 / 191.09 | 5 | 36 |
2 | 7 | 2003.92 | 40 | 14.65 | 3299 | 1933 | 2.15 / 193.03 | 36 | 74 |
3 | 13 | 1973.16 | 20 | 14.64 | 3280 | 960 | 3.11 / 193.99 | 5 | 78 |
4 | 13 | 1311.40 | 20 | 14.78 | 2343 | 693 | 3.80 / 194.68 | 5 | 91 |
5 | 13 | 576.08 | 20 | 15.00 | 1250 | 375 | 4.18 / 195.05 | 5 | 98 |
6 | 13 | 53.88 | 20 | 15.18 | 468 | 142 | 4.32 / 195.20 | 5 | 100 |
7 | 8 | 0.04 | 214 | 15.15 | 362 | 1174 | 5.50 / 196.37 | 5 | 130 |
Average= | 5.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 28 | 15.14 | 504 | 214 | 0.21 / 185.54 | 5 | 38 |
2 | 7 | 2008.64 | 40 | 14.65 | 3314 | 1942 | 2.16 / 187.49 | 38 | 75 |
3 | 13 | 1976.72 | 20 | 14.63 | 3298 | 965 | 3.12 / 188.45 | 5 | 78 |
4 | 13 | 1333.28 | 20 | 14.78 | 2359 | 697 | 3.82 / 189.15 | 5 | 91 |
5 | 13 | 583.24 | 20 | 15.00 | 1255 | 376 | 4.19 / 189.53 | 5 | 96 |
6 | 13 | 81.28 | 20 | 15.17 | 509 | 154 | 4.35 / 189.68 | 5 | 96 |
7 | 8 | -0.08 | 219 | 15.15 | 360 | 1194 | 5.54 / 190.87 | 5 | 133 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 28 | 15.17 | 516 | 219 | 0.22 / 180.00 | 5 | 34 |
2 | 7 | 2010.28 | 40 | 14.64 | 3326 | 1948 | 2.17 / 181.95 | 34 | 75 |
3 | 13 | 1979.96 | 20 | 14.63 | 3284 | 961 | 3.13 / 182.91 | 5 | 78 |
4 | 13 | 1267.36 | 20 | 14.79 | 2294 | 679 | 3.81 / 183.59 | 5 | 93 |
5 | 13 | 584.96 | 20 | 15.00 | 1249 | 375 | 4.18 / 183.96 | 5 | 98 |
6 | 13 | 60.32 | 20 | 15.18 | 484 | 147 | 4.33 / 184.11 | 5 | 95 |
7 | 13 | 14.44 | 20 | 15.19 | 406 | 123 | 4.45 / 184.23 | 5 | 102 |
8 | 8 | -0.08 | 197 | 15.14 | 363 | 1083 | 5.53 / 185.31 | 5 | 129 |
9 | 14 | -0.12 | 3 | 15.11 | 364 | 17 | 5.55 / 185.33 | 28 | 97 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 28 | 15.18 | 494 | 210 | 0.21 / 174.54 | 5 | 30 |
2 | 7 | 2004.32 | 40 | 14.66 | 3291 | 1930 | 2.14 / 176.47 | 30 | 73 |
3 | 13 | 1972.12 | 20 | 14.65 | 3292 | 965 | 3.10 / 177.43 | 5 | 77 |
4 | 13 | 1301.60 | 20 | 14.79 | 2346 | 694 | 3.80 / 178.12 | 5 | 92 |
5 | 13 | 687.84 | 20 | 14.97 | 1414 | 423 | 4.22 / 178.55 | 5 | 96 |
6 | 13 | 35.20 | 20 | 15.22 | 415 | 126 | 4.35 / 178.67 | 5 | 79 |
7 | 8 | 0.04 | 212 | 15.18 | 344 | 1107 | 5.46 / 179.78 | 5 | 139 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 28 | 15.17 | 477 | 203 | 0.20 / 169.06 | 5 | 28 |
2 | 7 | 2012.72 | 40 | 14.67 | 3312 | 1943 | 2.15 / 171.01 | 28 | 73 |
3 | 13 | 1986.40 | 20 | 14.65 | 3282 | 962 | 3.11 / 171.97 | 5 | 77 |
4 | 13 | 1438.88 | 20 | 14.76 | 2530 | 747 | 3.85 / 172.71 | 5 | 89 |
5 | 13 | 646.08 | 20 | 15.00 | 1348 | 404 | 4.26 / 173.12 | 5 | 96 |
6 | 13 | 17.24 | 20 | 15.24 | 376 | 115 | 4.37 / 173.23 | 5 | 78 |
7 | 8 | 0.28 | 216 | 15.19 | 333 | 1093 | 5.47 / 174.33 | 5 | 139 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 28 | 15.18 | 497 | 211 | 0.21 / 163.68 | 5 | 29 |
2 | 7 | 2010.32 | 40 | 14.66 | 3310 | 1941 | 2.15 / 165.62 | 9 | 74 |
3 | 13 | 1986.40 | 20 | 14.65 | 3313 | 971 | 3.12 / 166.59 | 5 | 77 |
4 | 13 | 1181.36 | 20 | 14.84 | 2147 | 637 | 3.76 / 167.23 | 5 | 93 |
5 | 13 | 535.60 | 20 | 15.04 | 1169 | 352 | 4.11 / 167.58 | 5 | 97 |
6 | 13 | 46.04 | 20 | 15.22 | 427 | 130 | 4.24 / 167.71 | 5 | 88 |
7 | 13 | 25.76 | 20 | 15.22 | 393 | 120 | 4.36 / 167.83 | 5 | 87 |
8 | 8 | 0.00 | 195 | 15.18 | 339 | 1003 | 5.36 / 168.83 | 5 | 132 |
9 | 14 | -0.12 | 5 | 15.15 | 339 | 26 | 5.39 / 168.86 | 43 | 141 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 28 | 15.16 | 482 | 205 | 0.20 / 158.24 | 5 | 29 |
2 | 7 | 2013.60 | 40 | 14.67 | 3328 | 1953 | 2.16 / 160.19 | 29 | 74 |
3 | 13 | 1982.96 | 20 | 14.66 | 3317 | 973 | 3.13 / 161.16 | 5 | 77 |
4 | 13 | 1251.20 | 20 | 14.83 | 2246 | 666 | 3.80 / 161.83 | 5 | 92 |
5 | 13 | 539.48 | 20 | 15.04 | 1178 | 354 | 4.15 / 162.18 | 5 | 97 |
6 | 13 | 75.00 | 20 | 15.21 | 491 | 149 | 4.30 / 162.33 | 5 | 95 |
7 | 8 | 0.12 | 214 | 15.18 | 350 | 1137 | 5.44 / 163.47 | 5 | 129 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 28 | 15.19 | 486 | 207 | 0.21 / 152.76 | 5 | 27 |
2 | 7 | 2005.64 | 40 | 14.67 | 3324 | 1951 | 2.16 / 154.71 | 6 | 73 |
3 | 13 | 1973.80 | 20 | 14.66 | 3287 | 964 | 3.12 / 155.67 | 5 | 77 |
4 | 13 | 1189.76 | 20 | 14.85 | 2153 | 639 | 3.76 / 156.31 | 5 | 92 |
5 | 13 | 531.28 | 20 | 15.04 | 1171 | 352 | 4.11 / 156.66 | 5 | 97 |
6 | 13 | 77.12 | 20 | 15.20 | 502 | 153 | 4.27 / 156.82 | 5 | 93 |
7 | 13 | 23.08 | 20 | 15.21 | 417 | 127 | 4.39 / 156.94 | 5 | 96 |
8 | 8 | -0.04 | 197 | 15.16 | 359 | 1072 | 5.46 / 158.02 | 5 | 132 |
9 | 14 | -0.20 | 3 | 15.14 | 360 | 16 | 5.48 / 158.03 | 33 | 94 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 28 | 15.20 | 494 | 210 | 0.21 / 147.23 | 5 | 26 |
2 | 7 | 2010.64 | 40 | 14.67 | 3306 | 1940 | 2.15 / 149.17 | 11 | 72 |
3 | 13 | 1981.96 | 20 | 14.67 | 3283 | 963 | 3.11 / 150.13 | 5 | 76 |
4 | 13 | 1253.16 | 20 | 14.83 | 2263 | 671 | 3.78 / 150.80 | 5 | 91 |
5 | 13 | 616.04 | 20 | 15.02 | 1300 | 391 | 4.18 / 151.19 | 5 | 97 |
6 | 13 | 257.76 | 20 | 15.14 | 781 | 236 | 4.41 / 151.43 | 5 | 96 |
7 | 8 | 0.00 | 216 | 15.18 | 343 | 1125 | 5.54 / 152.55 | 5 | 132 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 28 | 15.15 | 519 | 220 | 0.22 / 141.87 | 5 | 43 |
2 | 7 | 2008.48 | 40 | 14.68 | 3313 | 1945 | 2.17 / 143.82 | 43 | 73 |
3 | 13 | 1801.96 | 20 | 14.73 | 3054 | 900 | 3.07 / 144.72 | 5 | 80 |
4 | 13 | 1275.72 | 20 | 14.83 | 2272 | 674 | 3.74 / 145.39 | 5 | 88 |
5 | 13 | 551.72 | 20 | 15.05 | 1235 | 372 | 4.11 / 145.76 | 5 | 98 |
6 | 13 | 62.44 | 20 | 15.23 | 467 | 142 | 4.25 / 145.91 | 5 | 81 |
7 | 8 | 0.04 | 214 | 15.20 | 341 | 1109 | 5.36 / 147.02 | 5 | 136 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 28 | 15.20 | 505 | 215 | 0.21 / 136.21 | 5 | 25 |
2 | 7 | 2006.92 | 40 | 14.67 | 3313 | 1944 | 2.16 / 138.15 | 25 | 74 |
3 | 13 | 1975.92 | 20 | 14.67 | 3290 | 965 | 3.12 / 139.12 | 5 | 77 |
4 | 13 | 1159.84 | 20 | 14.86 | 2131 | 633 | 3.76 / 139.75 | 5 | 94 |
5 | 13 | 592.92 | 20 | 15.03 | 1249 | 375 | 4.13 / 140.13 | 5 | 95 |
6 | 13 | 122.16 | 20 | 15.18 | 584 | 177 | 4.31 / 140.30 | 5 | 97 |
7 | 8 | 0.12 | 238 | 15.16 | 374 | 1349 | 5.66 / 141.65 | 5 | 140 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 28 | 15.22 | 470 | 200 | 0.20 / 130.22 | 5 | 24 |
2 | 7 | 2004.20 | 40 | 14.70 | 3310 | 1946 | 2.15 / 132.16 | 24 | 71 |
3 | 13 | 1976.92 | 20 | 14.69 | 3283 | 965 | 3.11 / 133.13 | 5 | 75 |
4 | 13 | 1396.84 | 20 | 14.81 | 2439 | 722 | 3.83 / 133.85 | 5 | 85 |
5 | 13 | 1023.56 | 20 | 14.90 | 1884 | 561 | 4.39 / 134.41 | 5 | 92 |
6 | 13 | 736.44 | 20 | 14.97 | 1482 | 444 | 4.84 / 134.85 | 5 | 94 |
7 | 13 | 14.76 | 20 | 15.24 | 367 | 112 | 4.95 / 134.97 | 5 | 75 |
8 | 8 | 0.04 | 201 | 15.20 | 336 | 1027 | 5.98 / 135.99 | 5 | 135 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 28 | 15.21 | 499 | 213 | 0.21 / 124.60 | 5 | 31 |
2 | 7 | 2010.32 | 40 | 14.70 | 3317 | 1950 | 2.16 / 126.55 | 31 | 71 |
3 | 13 | 1979.72 | 20 | 14.69 | 3278 | 963 | 3.13 / 127.51 | 5 | 74 |
4 | 13 | 1464.80 | 20 | 14.78 | 2550 | 754 | 3.88 / 128.27 | 5 | 84 |
5 | 13 | 752.60 | 20 | 14.99 | 1517 | 455 | 4.33 / 128.72 | 5 | 93 |
6 | 13 | 197.80 | 20 | 15.20 | 668 | 203 | 4.54 / 128.92 | 5 | 76 |
7 | 8 | 0.04 | 218 | 15.22 | 329 | 1092 | 5.63 / 130.02 | 5 | 133 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 28 | 15.21 | 490 | 209 | 0.21 / 119.09 | 5 | 31 |
2 | 7 | 2011.52 | 40 | 14.70 | 3331 | 1959 | 2.17 / 121.05 | 31 | 72 |
3 | 13 | 1979.16 | 20 | 14.69 | 3288 | 966 | 3.13 / 122.02 | 5 | 74 |
4 | 13 | 1229.56 | 20 | 14.87 | 2201 | 655 | 3.79 / 122.67 | 5 | 87 |
5 | 13 | 792.80 | 20 | 14.98 | 1557 | 466 | 4.25 / 123.14 | 5 | 93 |
6 | 13 | 54.68 | 20 | 15.26 | 435 | 133 | 4.39 / 123.27 | 5 | 72 |
7 | 8 | 0.16 | 219 | 15.23 | 334 | 1114 | 5.50 / 124.39 | 5 | 135 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 28 | 15.23 | 479 | 204 | 0.20 / 113.35 | 5 | 29 |
2 | 7 | 2012.40 | 40 | 14.70 | 3316 | 1950 | 2.15 / 115.30 | 29 | 71 |
3 | 13 | 1982.64 | 20 | 14.69 | 3284 | 965 | 3.12 / 116.27 | 5 | 75 |
4 | 13 | 1401.20 | 20 | 14.81 | 2455 | 727 | 3.85 / 116.99 | 5 | 87 |
5 | 13 | 994.48 | 20 | 14.90 | 1877 | 559 | 4.41 / 117.55 | 5 | 94 |
6 | 13 | 233.44 | 20 | 15.18 | 730 | 222 | 4.63 / 117.77 | 5 | 90 |
7 | 8 | -0.04 | 218 | 15.21 | 335 | 1111 | 5.74 / 118.89 | 5 | 137 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 28 | 15.24 | 474 | 202 | 0.20 / 107.71 | 5 | 37 |
2 | 3 | 1021.28 | 1 | 15.25 | 1952 | 30 | 0.23 / 107.74 | 5 | 20 |
3 | 7 | 2011.08 | 40 | 14.71 | 3323 | 1955 | 2.19 / 109.69 | 20 | 69 |
4 | 13 | 1980.04 | 20 | 14.70 | 3311 | 973 | 3.16 / 110.67 | 5 | 73 |
5 | 13 | 1498.52 | 20 | 14.79 | 2589 | 766 | 3.93 / 111.43 | 5 | 82 |
6 | 13 | 891.44 | 20 | 14.96 | 1701 | 509 | 4.44 / 111.94 | 5 | 91 |
7 | 13 | 88.24 | 20 | 15.26 | 474 | 145 | 4.58 / 112.09 | 5 | 70 |
8 | 8 | 0.08 | 218 | 15.24 | 319 | 1060 | 5.64 / 113.15 | 5 | 136 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 28 | 15.20 | 516 | 220 | 0.22 / 102.13 | 5 | 45 |
2 | 7 | 2011.16 | 41 | 14.73 | 3321 | 2006 | 2.23 / 104.14 | 45 | 68 |
3 | 13 | 1983.24 | 20 | 14.72 | 3273 | 964 | 3.19 / 105.10 | 5 | 70 |
4 | 13 | 1418.52 | 20 | 14.83 | 2490 | 739 | 3.93 / 105.84 | 5 | 83 |
5 | 13 | 962.80 | 20 | 14.95 | 1829 | 547 | 4.47 / 106.39 | 5 | 90 |
6 | 8 | 0.36 | 235 | 15.26 | 312 | 1119 | 5.59 / 107.51 | 5 | 133 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 28 | 15.18 | 533 | 227 | 0.23 / 96.65 | 5 | 62 |
2 | 7 | 2008.92 | 40 | 14.72 | 3301 | 1944 | 2.17 / 98.59 | 62 | 72 |
3 | 13 | 1978.72 | 20 | 14.71 | 3287 | 967 | 3.14 / 99.56 | 5 | 75 |
4 | 13 | 1263.96 | 20 | 14.86 | 2252 | 669 | 3.81 / 100.23 | 5 | 89 |
5 | 13 | 734.20 | 20 | 15.01 | 1465 | 440 | 4.25 / 100.67 | 5 | 94 |
6 | 13 | 64.00 | 20 | 15.24 | 470 | 143 | 4.39 / 100.81 | 5 | 91 |
7 | 8 | 0.00 | 208 | 15.21 | 348 | 1101 | 5.49 / 101.91 | 5 | 136 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 27 | 15.19 | 504 | 207 | 0.21 / 91.20 | 5 | 53 |
2 | 3 | 1018.96 | 1 | 15.20 | 1985 | 30 | 0.24 / 91.23 | 5 | 19 |
3 | 7 | 2006.16 | 40 | 14.72 | 3313 | 1951 | 2.19 / 93.18 | 19 | 72 |
4 | 13 | 1717.92 | 20 | 14.78 | 2920 | 863 | 3.05 / 94.05 | 5 | 80 |
5 | 13 | 1248.32 | 20 | 14.87 | 2237 | 665 | 3.72 / 94.71 | 5 | 89 |
6 | 13 | 505.84 | 20 | 15.09 | 1132 | 342 | 4.06 / 95.05 | 5 | 95 |
7 | 8 | -0.12 | 253 | 15.21 | 356 | 1370 | 5.43 / 96.42 | 5 | 131 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 27 | 15.21 | 500 | 205 | 0.21 / 85.85 | 5 | 40 |
2 | 7 | 2006.08 | 40 | 14.73 | 3291 | 1939 | 2.14 / 87.79 | 40 | 72 |
3 | 13 | 1763.48 | 20 | 14.78 | 2982 | 881 | 3.03 / 88.67 | 5 | 79 |
4 | 13 | 1107.92 | 20 | 14.92 | 2025 | 604 | 3.63 / 89.27 | 5 | 92 |
5 | 13 | 593.08 | 20 | 15.06 | 1260 | 380 | 4.01 / 89.65 | 5 | 95 |
6 | 13 | 60.76 | 20 | 15.24 | 458 | 140 | 4.15 / 89.79 | 5 | 93 |
7 | 8 | 0.20 | 227 | 15.21 | 349 | 1205 | 5.35 / 91.00 | 5 | 139 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 27 | 15.25 | 445 | 183 | 0.18 / 80.60 | 5 | 29 |
2 | 7 | 2005.20 | 40 | 14.74 | 3272 | 1929 | 2.11 / 82.53 | 29 | 72 |
3 | 13 | 1695.20 | 20 | 14.80 | 2843 | 842 | 2.95 / 83.37 | 5 | 80 |
4 | 13 | 1130.16 | 20 | 14.93 | 1994 | 595 | 3.55 / 83.96 | 5 | 88 |
5 | 13 | 576.64 | 20 | 15.08 | 1182 | 356 | 3.91 / 84.32 | 5 | 96 |
6 | 13 | 303.56 | 20 | 15.16 | 789 | 239 | 4.15 / 84.56 | 5 | 97 |
7 | 8 | -0.24 | 221 | 15.22 | 322 | 1083 | 5.23 / 85.64 | 5 | 133 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 27 | 15.26 | 443 | 183 | 0.18 / 75.28 | 5 | 26 |
2 | 7 | 2010.00 | 40 | 14.76 | 3263 | 1926 | 2.11 / 77.20 | 26 | 69 |
3 | 13 | 1986.24 | 20 | 14.75 | 3217 | 949 | 3.06 / 78.15 | 5 | 72 |
4 | 13 | 1500.36 | 20 | 14.83 | 2561 | 760 | 3.82 / 78.91 | 5 | 85 |
5 | 13 | 622.28 | 20 | 15.09 | 1276 | 385 | 4.20 / 79.30 | 5 | 95 |
6 | 13 | 176.72 | 20 | 15.25 | 582 | 178 | 4.38 / 79.47 | 5 | 81 |
7 | 8 | -0.08 | 216 | 15.26 | 285 | 939 | 5.32 / 80.41 | 5 | 141 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 27 | 15.21 | 483 | 198 | 0.20 / 70.16 | 5 | 56 |
2 | 3 | 1018.84 | 1 | 15.22 | 1952 | 30 | 0.23 / 70.19 | 5 | 19 |
3 | 7 | 2007.88 | 40 | 14.75 | 3278 | 1934 | 2.16 / 72.12 | 19 | 74 |
4 | 13 | 1909.72 | 20 | 14.76 | 3155 | 931 | 3.09 / 73.05 | 5 | 78 |
5 | 13 | 1174.00 | 20 | 14.92 | 2095 | 625 | 3.72 / 73.68 | 5 | 93 |
6 | 13 | 572.12 | 20 | 15.10 | 1198 | 362 | 4.08 / 74.04 | 5 | 98 |
7 | 13 | 49.28 | 20 | 15.30 | 369 | 113 | 4.19 / 74.15 | 5 | 75 |
8 | 8 | 0.12 | 214 | 15.26 | 288 | 941 | 5.13 / 75.09 | 5 | 142 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 27 | 15.24 | 462 | 190 | 0.19 / 64.88 | 5 | 34 |
2 | 7 | 2004.68 | 40 | 14.74 | 3279 | 1933 | 2.12 / 66.82 | 34 | 74 |
3 | 13 | 1834.12 | 20 | 14.78 | 3040 | 899 | 3.02 / 67.72 | 5 | 80 |
4 | 13 | 1235.80 | 20 | 14.90 | 2153 | 642 | 3.66 / 68.36 | 5 | 91 |
5 | 13 | 523.80 | 20 | 15.11 | 1101 | 333 | 4.00 / 68.69 | 5 | 98 |
6 | 13 | 49.44 | 20 | 15.27 | 400 | 122 | 4.12 / 68.81 | 5 | 94 |
7 | 8 | 0.16 | 238 | 15.23 | 317 | 1149 | 5.27 / 69.96 | 5 | 129 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 27 | 15.24 | 465 | 191 | 0.19 / 59.65 | 5 | 31 |
2 | 7 | 2008.00 | 40 | 14.76 | 3280 | 1937 | 2.13 / 61.59 | 31 | 71 |
3 | 13 | 1980.44 | 20 | 14.75 | 3242 | 956 | 3.08 / 62.54 | 5 | 75 |
4 | 13 | 1250.52 | 20 | 14.90 | 2176 | 648 | 3.73 / 63.19 | 5 | 87 |
5 | 13 | 598.92 | 20 | 15.09 | 1219 | 368 | 4.10 / 63.56 | 5 | 94 |
6 | 13 | 41.68 | 20 | 15.28 | 384 | 117 | 4.22 / 63.68 | 5 | 92 |
7 | 8 | -0.04 | 216 | 15.25 | 309 | 1018 | 5.24 / 64.69 | 5 | 142 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 27 | 15.21 | 489 | 201 | 0.20 / 54.34 | 5 | 66 |
2 | 10 | 1003.24 | 3 | 15.11 | 1870 | 85 | 0.29 / 54.43 | 5 | 72 |
3 | 3 | 904.16 | -1 | 15.54 | 0 | 0 | 0.08 / 54.43 | 5 | 72 |
4 | 7 | 2006.60 | 40 | 14.76 | 3267 | 1929 | 2.21 / 56.36 | 72 | 72 |
5 | 13 | 1869.80 | 20 | 14.78 | 3101 | 917 | 3.13 / 57.27 | 5 | 78 |
6 | 13 | 1179.68 | 20 | 14.93 | 2073 | 619 | 3.75 / 57.89 | 5 | 88 |
7 | 13 | 513.48 | 20 | 15.12 | 1091 | 330 | 4.08 / 58.22 | 5 | 96 |
8 | 13 | 166.44 | 20 | 15.23 | 582 | 177 | 4.26 / 58.40 | 5 | 93 |
9 | 8 | -0.16 | 223 | 15.24 | 311 | 1057 | 5.31 / 59.46 | 5 | 131 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 27 | 15.23 | 482 | 198 | 0.20 / 48.92 | 5 | 42 |
2 | 7 | 1991.92 | 40 | 14.76 | 3256 | 1922 | 2.12 / 50.84 | 42 | 75 |
3 | 13 | 1827.44 | 20 | 14.79 | 3039 | 899 | 3.02 / 51.74 | 5 | 81 |
4 | 13 | 1375.40 | 20 | 14.86 | 2379 | 707 | 3.73 / 52.45 | 5 | 90 |
5 | 13 | 640.88 | 20 | 15.07 | 1288 | 388 | 4.11 / 52.84 | 5 | 96 |
6 | 13 | 52.20 | 20 | 15.27 | 408 | 125 | 4.24 / 52.96 | 5 | 91 |
7 | 8 | 0.12 | 242 | 15.23 | 321 | 1183 | 5.42 / 54.14 | 5 | 129 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 27 | 15.22 | 500 | 205 | 0.21 / 43.69 | 5 | 60 |
2 | 7 | 2010.56 | 41 | 14.76 | 3287 | 1989 | 2.19 / 45.68 | 60 | 73 |
3 | 13 | 1978.68 | 20 | 14.76 | 3239 | 956 | 3.15 / 46.64 | 5 | 77 |
4 | 13 | 1138.20 | 20 | 14.95 | 2009 | 601 | 3.75 / 47.24 | 5 | 91 |
5 | 13 | 462.76 | 20 | 15.14 | 1019 | 309 | 4.06 / 47.55 | 5 | 96 |
6 | 8 | 0.12 | 244 | 15.25 | 315 | 1172 | 5.23 / 48.72 | 5 | 130 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 27 | 15.22 | 503 | 207 | 0.21 / 38.36 | 5 | 61 |
2 | 7 | 2003.32 | 40 | 14.77 | 3274 | 1934 | 2.14 / 40.30 | 5 | 72 |
3 | 13 | 1973.64 | 20 | 14.76 | 3246 | 958 | 3.10 / 41.25 | 5 | 76 |
4 | 13 | 1240.12 | 20 | 14.92 | 2165 | 646 | 3.75 / 41.90 | 5 | 88 |
5 | 13 | 487.80 | 20 | 15.14 | 1061 | 321 | 4.07 / 42.22 | 5 | 95 |
6 | 13 | 68.80 | 20 | 15.27 | 437 | 133 | 4.20 / 42.35 | 5 | 90 |
7 | 8 | -0.20 | 231 | 15.24 | 322 | 1134 | 5.33 / 43.49 | 5 | 131 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 27 | 15.22 | 493 | 203 | 0.20 / 32.89 | 5 | 61 |
2 | 7 | 2009.76 | 40 | 14.78 | 3277 | 1937 | 2.14 / 34.83 | 61 | 72 |
3 | 13 | 1980.32 | 20 | 14.76 | 3261 | 963 | 3.10 / 35.79 | 5 | 75 |
4 | 13 | 1257.16 | 20 | 14.91 | 2193 | 654 | 3.76 / 36.45 | 5 | 86 |
5 | 13 | 669.84 | 20 | 15.08 | 1330 | 401 | 4.16 / 36.85 | 5 | 96 |
6 | 13 | 63.92 | 20 | 15.27 | 431 | 132 | 4.29 / 36.98 | 5 | 92 |
7 | 8 | 0.32 | 240 | 15.24 | 321 | 1174 | 5.46 / 38.16 | 5 | 132 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 27 | 15.22 | 497 | 204 | 0.20 / 27.53 | 5 | 56 |
2 | 7 | 2009.60 | 41 | 14.78 | 3269 | 1981 | 2.19 / 29.51 | 56 | 72 |
3 | 13 | 1909.40 | 20 | 14.78 | 3153 | 932 | 3.12 / 30.44 | 5 | 78 |
4 | 13 | 1240.24 | 20 | 14.92 | 2149 | 641 | 3.76 / 31.08 | 5 | 87 |
5 | 13 | 560.84 | 20 | 15.12 | 1160 | 351 | 4.11 / 31.43 | 5 | 94 |
6 | 13 | 13.44 | 20 | 15.30 | 344 | 105 | 4.21 / 31.54 | 5 | 91 |
7 | 8 | -0.20 | 240 | 15.24 | 316 | 1156 | 5.37 / 32.69 | 5 | 135 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 27 | 15.23 | 485 | 199 | 0.20 / 22.17 | 5 | 50 |
2 | 7 | 2009.88 | 40 | 14.78 | 3267 | 1931 | 2.13 / 24.10 | 50 | 72 |
3 | 13 | 1977.72 | 20 | 14.78 | 3240 | 958 | 3.09 / 25.06 | 5 | 76 |
4 | 13 | 1184.08 | 20 | 14.94 | 2077 | 621 | 3.71 / 25.68 | 5 | 89 |
5 | 13 | 502.12 | 20 | 15.14 | 1074 | 325 | 4.03 / 26.00 | 5 | 93 |
6 | 13 | 42.24 | 20 | 15.29 | 393 | 120 | 4.15 / 26.12 | 5 | 91 |
7 | 8 | 0.20 | 244 | 15.24 | 322 | 1197 | 5.35 / 27.32 | 5 | 132 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 24 | 15.24 | 480 | 176 | 0.18 / 16.97 | 5 | 47 |
2 | 10 | 1000.84 | 3 | 15.13 | 1862 | 85 | 0.26 / 17.05 | 5 | 71 |
3 | 7 | 2004.32 | 40 | 14.78 | 3271 | 1934 | 2.19 / 18.98 | 71 | 73 |
4 | 13 | 1803.64 | 20 | 14.81 | 3010 | 892 | 3.09 / 19.88 | 5 | 81 |
5 | 13 | 1133.16 | 20 | 14.96 | 1997 | 598 | 3.68 / 20.47 | 5 | 88 |
6 | 13 | 438.24 | 20 | 15.16 | 973 | 295 | 3.98 / 20.77 | 5 | 96 |
7 | 8 | 0.16 | 253 | 15.26 | 311 | 1201 | 5.18 / 21.97 | 5 | 134 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 31 | 15.22 | 467 | 220 | 0.22 / 11.59 | 5 | 41 |
2 | 3 | 762.44 | -4 | 15.55 | 0 | 0 | 0.00 / 11.59 | 5 | 41 |
3 | 7 | 2004.20 | 40 | 14.79 | 3263 | 1930 | 2.15 / 13.52 | 41 | 72 |
4 | 13 | 1973.08 | 20 | 14.78 | 3245 | 959 | 3.11 / 14.48 | 5 | 76 |
5 | 13 | 1565.48 | 20 | 14.83 | 2678 | 794 | 3.90 / 15.28 | 5 | 85 |
6 | 13 | 444.76 | 20 | 15.16 | 994 | 301 | 4.21 / 15.58 | 5 | 94 |
7 | 13 | 38.56 | 20 | 15.30 | 384 | 118 | 4.32 / 15.69 | 5 | 94 |
8 | 8 | -0.08 | 231 | 15.26 | 311 | 1096 | 5.42 / 16.79 | 5 | 133 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 5 | 15.25 | 460 | 35 | 0.04 / 6.81 | 5 | 30 |
2 | 7 | 1988.44 | 40 | 14.72 | 3248 | 1912 | 1.95 / 8.72 | 30 | 75 |
3 | 13 | 1553.24 | 20 | 14.82 | 2661 | 789 | 2.74 / 9.51 | 5 | 86 |
4 | 13 | 954.76 | 20 | 14.98 | 1719 | 515 | 3.25 / 10.02 | 5 | 91 |
5 | 13 | 208.92 | 20 | 15.21 | 649 | 197 | 3.45 / 10.22 | 5 | 92 |
6 | 8 | 0.00 | 244 | 15.23 | 310 | 1152 | 4.60 / 11.37 | 5 | 132 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 10 | 2000.60 | 4 | 14.84 | 3371 | 200 | 0.20 / 1.71 | 5 | 62 |
2 | 7 | 2089.80 | 40 | 14.67 | 3401 | 1996 | 2.20 / 3.71 | 62 | 73 |
3 | 13 | 1952.64 | 20 | 14.69 | 3214 | 944 | 3.14 / 4.65 | 5 | 78 |
4 | 13 | 1195.72 | 20 | 14.88 | 2089 | 622 | 3.76 / 5.27 | 5 | 90 |
5 | 13 | 440.68 | 20 | 15.13 | 984 | 298 | 4.06 / 5.57 | 5 | 95 |
6 | 8 | 0.64 | 253 | 15.24 | 311 | 1199 | 5.26 / 6.77 | 5 | 138 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 7 | 104.76 | 40 | 15.59 | 441 | 275 | 0.28 / 0.28 | 6 | 39 |
2 | 13 | 114.40 | 20 | 15.57 | 458 | 143 | 0.42 / 0.42 | 5 | 40 |
3 | 13 | 88.00 | 20 | 15.57 | 417 | 130 | 0.55 / 0.55 | 5 | 45 |
4 | 8 | 0.12 | 231 | 15.52 | 269 | 964 | 1.51 / 1.51 | 5 | 159 |
Average= | 1.51 (KJ/cycle) |