SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 13 | 15.12 | 466 | 92 | 0.09 / 267.85 | 6 | 6 |
2 | 7 | 2003.72 | 40 | 14.70 | 3173 | 1866 | 1.96 / 269.71 | 6 | 58 |
3 | 13 | 1734.12 | 20 | 14.72 | 2831 | 833 | 2.79 / 270.54 | 5 | 67 |
4 | 13 | 1272.56 | 20 | 14.79 | 2132 | 631 | 3.42 / 271.18 | 5 | 71 |
5 | 13 | 776.96 | 20 | 14.92 | 1400 | 418 | 3.84 / 271.59 | 5 | 67 |
6 | 13 | 185.88 | 20 | 15.10 | 612 | 185 | 4.02 / 271.78 | 5 | 71 |
7 | 8 | 0.12 | 263 | 15.11 | 293 | 1164 | 5.19 / 272.94 | 5 | 136 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 13 | 15.13 | 461 | 91 | 0.09 / 262.66 | 6 | 6 |
2 | 7 | 2009.48 | 40 | 14.71 | 3185 | 1874 | 1.96 / 264.54 | 6 | 58 |
3 | 13 | 1876.88 | 20 | 14.70 | 3011 | 885 | 2.85 / 265.42 | 5 | 63 |
4 | 13 | 1283.72 | 20 | 14.79 | 2156 | 638 | 3.49 / 266.06 | 5 | 75 |
5 | 13 | 652.80 | 20 | 14.96 | 1257 | 376 | 3.86 / 266.44 | 5 | 70 |
6 | 13 | 155.04 | 20 | 15.12 | 564 | 171 | 4.03 / 266.61 | 5 | 69 |
7 | 8 | 0.04 | 263 | 15.12 | 288 | 1145 | 5.18 / 267.75 | 5 | 138 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 13 | 15.13 | 482 | 95 | 0.09 / 257.43 | 6 | 7 |
2 | 7 | 2007.12 | 40 | 14.71 | 3172 | 1866 | 1.96 / 259.29 | 7 | 58 |
3 | 13 | 1974.92 | 20 | 14.69 | 3133 | 920 | 2.88 / 260.21 | 5 | 61 |
4 | 13 | 1308.36 | 20 | 14.79 | 2221 | 657 | 3.54 / 260.87 | 5 | 74 |
5 | 13 | 615.44 | 20 | 14.98 | 1230 | 369 | 3.91 / 261.24 | 5 | 76 |
6 | 13 | 159.76 | 20 | 15.12 | 572 | 173 | 4.08 / 261.41 | 5 | 70 |
7 | 8 | 0.16 | 263 | 15.12 | 292 | 1161 | 5.24 / 262.57 | 5 | 129 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 13 | 15.12 | 488 | 96 | 0.10 / 252.11 | 6 | 7 |
2 | 7 | 2010.88 | 40 | 14.73 | 3138 | 1849 | 1.94 / 253.96 | 7 | 56 |
3 | 13 | 1979.32 | 20 | 14.70 | 3157 | 928 | 2.87 / 254.89 | 5 | 61 |
4 | 13 | 1281.56 | 20 | 14.80 | 2187 | 647 | 3.52 / 255.54 | 5 | 76 |
5 | 13 | 723.56 | 20 | 14.94 | 1366 | 408 | 3.93 / 255.94 | 5 | 67 |
6 | 13 | 180.24 | 20 | 15.11 | 613 | 185 | 4.11 / 256.13 | 5 | 73 |
7 | 8 | 0.08 | 267 | 15.12 | 298 | 1203 | 5.32 / 257.33 | 5 | 137 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 13 | 15.10 | 483 | 95 | 0.09 / 246.76 | 5 | 10 |
2 | 7 | 2007.12 | 40 | 14.72 | 3205 | 1887 | 1.98 / 248.65 | 10 | 59 |
3 | 13 | 1976.36 | 20 | 14.68 | 3226 | 947 | 2.93 / 249.60 | 5 | 63 |
4 | 13 | 1164.80 | 20 | 14.84 | 2014 | 598 | 3.53 / 250.19 | 5 | 73 |
5 | 13 | 674.96 | 20 | 14.96 | 1286 | 385 | 3.91 / 250.58 | 5 | 71 |
6 | 13 | 105.64 | 20 | 15.13 | 489 | 148 | 4.06 / 250.73 | 5 | 71 |
7 | 8 | 0.16 | 276 | 15.11 | 309 | 1289 | 5.35 / 252.02 | 5 | 133 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 13 | 15.11 | 485 | 95 | 0.10 / 241.27 | 6 | 8 |
2 | 7 | 2004.96 | 40 | 14.73 | 3113 | 1834 | 1.93 / 243.10 | 8 | 56 |
3 | 13 | 1972.08 | 20 | 14.70 | 3098 | 911 | 2.84 / 244.01 | 5 | 60 |
4 | 13 | 1304.20 | 20 | 14.81 | 2197 | 651 | 3.49 / 244.66 | 5 | 73 |
5 | 13 | 732.28 | 20 | 14.94 | 1397 | 417 | 3.91 / 245.08 | 5 | 76 |
6 | 13 | 97.36 | 20 | 15.13 | 481 | 146 | 4.05 / 245.23 | 5 | 73 |
7 | 8 | -0.04 | 304 | 15.10 | 314 | 1441 | 5.50 / 246.67 | 5 | 131 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 13 | 15.12 | 474 | 93 | 0.09 / 235.79 | 6 | 7 |
2 | 7 | 2007.56 | 40 | 14.73 | 3140 | 1850 | 1.94 / 237.64 | 7 | 57 |
3 | 13 | 1975.68 | 20 | 14.70 | 3159 | 929 | 2.87 / 238.57 | 5 | 61 |
4 | 13 | 1346.72 | 20 | 14.80 | 2246 | 665 | 3.54 / 239.23 | 5 | 72 |
5 | 13 | 661.16 | 20 | 14.97 | 1291 | 387 | 3.92 / 239.62 | 5 | 78 |
6 | 13 | 89.16 | 20 | 15.14 | 460 | 139 | 4.06 / 239.76 | 5 | 72 |
7 | 8 | 0.12 | 302 | 15.11 | 310 | 1415 | 5.48 / 241.17 | 5 | 133 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 13 | 15.12 | 463 | 91 | 0.09 / 230.42 | 5 | 10 |
2 | 7 | 2009.92 | 40 | 14.73 | 3167 | 1866 | 1.96 / 232.29 | 10 | 58 |
3 | 13 | 1977.12 | 20 | 14.69 | 3181 | 935 | 2.89 / 233.22 | 5 | 61 |
4 | 13 | 1177.88 | 20 | 14.85 | 2012 | 598 | 3.49 / 233.82 | 5 | 72 |
5 | 13 | 666.20 | 20 | 14.99 | 1232 | 369 | 3.86 / 234.19 | 5 | 61 |
6 | 13 | 71.76 | 20 | 15.16 | 426 | 129 | 3.99 / 234.32 | 5 | 71 |
7 | 8 | 0.00 | 300 | 15.11 | 304 | 1378 | 5.37 / 235.70 | 5 | 132 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 13 | 15.12 | 474 | 93 | 0.09 / 225.01 | 5 | 8 |
2 | 7 | 2005.04 | 40 | 14.72 | 3218 | 1895 | 1.99 / 226.90 | 8 | 60 |
3 | 13 | 1871.80 | 20 | 14.73 | 3019 | 889 | 2.88 / 227.79 | 5 | 63 |
4 | 13 | 1294.12 | 20 | 14.81 | 2199 | 651 | 3.53 / 228.44 | 5 | 72 |
5 | 13 | 517.92 | 20 | 15.03 | 1049 | 315 | 3.84 / 228.76 | 5 | 67 |
6 | 13 | 80.48 | 20 | 15.15 | 450 | 136 | 3.98 / 228.90 | 5 | 72 |
7 | 8 | -0.04 | 308 | 15.11 | 308 | 1433 | 5.41 / 230.33 | 5 | 136 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 13 | 15.12 | 478 | 94 | 0.09 / 219.60 | 5 | 9 |
2 | 7 | 2005.00 | 40 | 14.74 | 3151 | 1858 | 1.95 / 221.46 | 9 | 57 |
3 | 13 | 1906.64 | 20 | 14.71 | 3079 | 906 | 2.86 / 222.36 | 5 | 63 |
4 | 13 | 1180.20 | 20 | 14.86 | 2016 | 599 | 3.46 / 222.96 | 5 | 70 |
5 | 13 | 705.52 | 20 | 14.97 | 1281 | 384 | 3.84 / 223.35 | 5 | 63 |
6 | 13 | 87.60 | 20 | 15.15 | 459 | 139 | 3.98 / 223.49 | 5 | 69 |
7 | 8 | 0.08 | 306 | 15.12 | 309 | 1430 | 5.41 / 224.92 | 5 | 139 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 13 | 15.13 | 484 | 95 | 0.10 / 214.20 | 5 | 8 |
2 | 7 | 2004.84 | 40 | 14.73 | 3191 | 1880 | 1.98 / 216.08 | 8 | 57 |
3 | 13 | 1973.20 | 20 | 14.69 | 3207 | 942 | 2.92 / 217.02 | 5 | 63 |
4 | 13 | 1164.32 | 20 | 14.87 | 1978 | 588 | 3.51 / 217.61 | 5 | 69 |
5 | 13 | 645.84 | 20 | 15.00 | 1218 | 365 | 3.87 / 217.97 | 5 | 62 |
6 | 13 | 76.00 | 20 | 15.16 | 444 | 135 | 4.01 / 218.11 | 5 | 70 |
7 | 8 | 0.04 | 302 | 15.12 | 306 | 1397 | 5.40 / 219.51 | 5 | 131 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 13 | 15.13 | 478 | 94 | 0.09 / 208.80 | 6 | 7 |
2 | 7 | 2010.24 | 40 | 14.74 | 3166 | 1867 | 1.96 / 210.66 | 7 | 58 |
3 | 13 | 1977.28 | 20 | 14.71 | 3135 | 922 | 2.88 / 211.59 | 5 | 62 |
4 | 13 | 1301.56 | 20 | 14.82 | 2178 | 646 | 3.53 / 212.23 | 5 | 71 |
5 | 13 | 534.56 | 20 | 15.04 | 1069 | 322 | 3.85 / 212.55 | 5 | 61 |
6 | 13 | 86.64 | 20 | 15.16 | 444 | 135 | 3.98 / 212.69 | 5 | 71 |
7 | 8 | 0.20 | 306 | 15.12 | 306 | 1416 | 5.40 / 214.10 | 5 | 133 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 13 | 15.13 | 480 | 94 | 0.09 / 203.37 | 5 | 8 |
2 | 7 | 2006.68 | 41 | 14.72 | 3247 | 1960 | 2.05 / 205.33 | 8 | 59 |
3 | 13 | 1768.52 | 20 | 14.75 | 2905 | 857 | 2.91 / 206.19 | 5 | 65 |
4 | 13 | 1290.20 | 20 | 14.83 | 2190 | 650 | 3.56 / 206.84 | 5 | 71 |
5 | 13 | 571.68 | 20 | 15.02 | 1112 | 334 | 3.89 / 207.17 | 5 | 59 |
6 | 13 | 72.00 | 20 | 15.16 | 432 | 131 | 4.03 / 207.31 | 5 | 71 |
7 | 8 | 0.20 | 304 | 15.12 | 304 | 1397 | 5.42 / 208.70 | 5 | 131 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 13 | 15.13 | 504 | 99 | 0.10 / 198.02 | 6 | 8 |
2 | 7 | 2003.16 | 40 | 14.75 | 3175 | 1873 | 1.97 / 199.89 | 8 | 58 |
3 | 13 | 1803.48 | 20 | 14.74 | 2945 | 868 | 2.84 / 200.76 | 5 | 64 |
4 | 13 | 1222.56 | 20 | 14.85 | 2104 | 625 | 3.47 / 201.38 | 5 | 73 |
5 | 13 | 585.52 | 20 | 15.01 | 1163 | 349 | 3.81 / 201.73 | 5 | 65 |
6 | 13 | 57.24 | 20 | 15.18 | 413 | 125 | 3.94 / 201.86 | 5 | 72 |
7 | 8 | 0.04 | 300 | 15.13 | 313 | 1421 | 5.36 / 203.28 | 5 | 133 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 13 | 15.13 | 489 | 96 | 0.10 / 192.49 | 6 | 7 |
2 | 7 | 2008.96 | 40 | 14.73 | 3228 | 1902 | 2.00 / 194.39 | 7 | 59 |
3 | 13 | 1976.00 | 20 | 14.70 | 3219 | 946 | 2.94 / 195.34 | 5 | 62 |
4 | 13 | 1340.04 | 20 | 14.82 | 2288 | 678 | 3.62 / 196.01 | 5 | 76 |
5 | 13 | 548.56 | 20 | 15.04 | 1105 | 332 | 3.96 / 196.35 | 5 | 66 |
6 | 13 | 91.56 | 20 | 15.16 | 473 | 143 | 4.10 / 196.49 | 5 | 71 |
7 | 8 | -0.04 | 302 | 15.13 | 313 | 1430 | 5.53 / 197.92 | 5 | 144 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 13 | 15.14 | 499 | 98 | 0.10 / 187.06 | 6 | 6 |
2 | 7 | 2008.20 | 40 | 14.75 | 3155 | 1861 | 1.96 / 188.93 | 6 | 57 |
3 | 13 | 1942.40 | 20 | 14.73 | 3071 | 905 | 2.86 / 189.83 | 5 | 61 |
4 | 13 | 1249.08 | 20 | 14.85 | 2136 | 634 | 3.50 / 190.47 | 5 | 75 |
5 | 13 | 680.64 | 20 | 14.99 | 1296 | 389 | 3.89 / 190.85 | 5 | 64 |
6 | 13 | 67.12 | 20 | 15.18 | 428 | 130 | 4.02 / 190.98 | 5 | 71 |
7 | 8 | 0.84 | 300 | 15.13 | 310 | 1407 | 5.42 / 192.39 | 5 | 137 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 13 | 15.15 | 498 | 98 | 0.10 / 181.75 | 6 | 6 |
2 | 7 | 2007.36 | 40 | 14.77 | 3074 | 1816 | 1.91 / 183.56 | 6 | 54 |
3 | 13 | 1840.72 | 20 | 14.75 | 2959 | 873 | 2.79 / 184.43 | 5 | 63 |
4 | 13 | 1322.68 | 20 | 14.84 | 2218 | 658 | 3.45 / 185.09 | 5 | 73 |
5 | 13 | 652.52 | 20 | 15.02 | 1206 | 362 | 3.81 / 185.46 | 5 | 59 |
6 | 13 | 103.88 | 20 | 15.17 | 482 | 146 | 3.95 / 185.60 | 5 | 71 |
7 | 8 | 0.04 | 289 | 15.14 | 312 | 1365 | 5.32 / 186.97 | 5 | 133 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 13 | 15.15 | 497 | 98 | 0.10 / 176.36 | 6 | 6 |
2 | 7 | 2010.04 | 40 | 14.75 | 3182 | 1877 | 1.98 / 178.24 | 6 | 55 |
3 | 13 | 1978.04 | 20 | 14.71 | 3167 | 932 | 2.91 / 179.17 | 5 | 61 |
4 | 13 | 1306.04 | 20 | 14.83 | 2219 | 658 | 3.57 / 179.83 | 5 | 74 |
5 | 13 | 597.20 | 20 | 15.03 | 1160 | 349 | 3.91 / 180.17 | 5 | 61 |
6 | 13 | 109.56 | 20 | 15.17 | 498 | 151 | 4.06 / 180.32 | 5 | 73 |
7 | 8 | 0.16 | 280 | 15.14 | 312 | 1323 | 5.39 / 181.65 | 5 | 132 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 13 | 15.15 | 486 | 96 | 0.10 / 171.03 | 6 | 6 |
2 | 7 | 2004.40 | 40 | 14.75 | 3186 | 1880 | 1.98 / 172.91 | 6 | 58 |
3 | 13 | 1905.40 | 20 | 14.74 | 3082 | 909 | 2.88 / 173.82 | 5 | 63 |
4 | 13 | 1209.24 | 20 | 14.87 | 2065 | 614 | 3.50 / 174.43 | 5 | 72 |
5 | 13 | 617.48 | 20 | 15.03 | 1191 | 358 | 3.86 / 174.79 | 5 | 59 |
6 | 13 | 85.24 | 20 | 15.18 | 456 | 138 | 3.99 / 174.93 | 5 | 70 |
7 | 8 | 0.00 | 282 | 15.15 | 311 | 1329 | 5.32 / 176.26 | 5 | 136 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 13 | 15.15 | 484 | 95 | 0.10 / 165.64 | 6 | 7 |
2 | 7 | 2009.40 | 40 | 14.76 | 3190 | 1883 | 1.98 / 167.52 | 7 | 58 |
3 | 13 | 1877.08 | 20 | 14.75 | 3035 | 895 | 2.87 / 168.42 | 5 | 63 |
4 | 13 | 1245.96 | 20 | 14.86 | 2134 | 634 | 3.51 / 169.05 | 5 | 71 |
5 | 13 | 587.12 | 20 | 15.04 | 1149 | 346 | 3.85 / 169.40 | 5 | 59 |
6 | 13 | 92.16 | 20 | 15.18 | 470 | 143 | 4.00 / 169.54 | 5 | 68 |
7 | 8 | 0.20 | 293 | 15.15 | 314 | 1394 | 5.39 / 170.94 | 5 | 134 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 13 | 15.15 | 488 | 96 | 0.10 / 160.22 | 5 | 6 |
2 | 7 | 2004.32 | 40 | 14.77 | 3141 | 1856 | 1.95 / 162.07 | 6 | 56 |
3 | 13 | 1971.84 | 20 | 14.74 | 3135 | 924 | 2.88 / 163.00 | 5 | 60 |
4 | 13 | 1255.88 | 20 | 14.87 | 2139 | 636 | 3.51 / 163.63 | 5 | 75 |
5 | 13 | 561.84 | 20 | 15.05 | 1120 | 337 | 3.85 / 163.97 | 5 | 61 |
6 | 13 | 105.24 | 20 | 15.18 | 485 | 147 | 4.00 / 164.12 | 5 | 71 |
7 | 8 | 0.08 | 300 | 15.15 | 314 | 1427 | 5.42 / 165.55 | 5 | 136 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 13 | 15.16 | 480 | 95 | 0.09 / 154.87 | 6 | 6 |
2 | 7 | 2004.92 | 40 | 14.76 | 3189 | 1883 | 1.98 / 156.75 | 6 | 58 |
3 | 13 | 1873.04 | 20 | 14.76 | 3055 | 902 | 2.88 / 157.65 | 5 | 64 |
4 | 13 | 1166.24 | 20 | 14.88 | 2032 | 605 | 3.48 / 158.26 | 5 | 73 |
5 | 13 | 648.16 | 20 | 15.01 | 1266 | 380 | 3.86 / 158.64 | 5 | 74 |
6 | 13 | 71.48 | 20 | 15.19 | 434 | 132 | 4.00 / 158.77 | 5 | 72 |
7 | 8 | 0.04 | 287 | 15.15 | 311 | 1352 | 5.35 / 160.12 | 5 | 137 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 13 | 15.17 | 467 | 92 | 0.09 / 149.58 | 6 | 6 |
2 | 7 | 2006.16 | 40 | 14.74 | 3233 | 1906 | 2.00 / 151.49 | 6 | 60 |
3 | 13 | 1837.28 | 20 | 14.75 | 2996 | 884 | 2.88 / 152.37 | 5 | 64 |
4 | 13 | 1178.44 | 20 | 14.87 | 2062 | 613 | 3.50 / 152.99 | 5 | 76 |
5 | 13 | 516.88 | 20 | 15.06 | 1100 | 331 | 3.83 / 153.32 | 5 | 79 |
6 | 13 | 87.80 | 20 | 15.19 | 466 | 142 | 3.97 / 153.46 | 5 | 76 |
7 | 8 | 0.04 | 276 | 15.16 | 314 | 1314 | 5.28 / 154.77 | 5 | 142 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 13 | 15.17 | 470 | 93 | 0.09 / 144.36 | 6 | 6 |
2 | 7 | 2006.80 | 40 | 14.76 | 3194 | 1886 | 1.98 / 146.24 | 6 | 57 |
3 | 13 | 1841.24 | 20 | 14.77 | 2995 | 885 | 2.86 / 147.13 | 5 | 64 |
4 | 13 | 1157.68 | 20 | 14.90 | 1986 | 592 | 3.45 / 147.72 | 5 | 71 |
5 | 13 | 564.44 | 20 | 15.05 | 1138 | 343 | 3.80 / 148.06 | 5 | 73 |
6 | 13 | 137.08 | 20 | 15.18 | 536 | 163 | 3.96 / 148.22 | 5 | 70 |
7 | 8 | 0.08 | 276 | 15.17 | 303 | 1269 | 5.23 / 149.49 | 5 | 133 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 13 | 15.18 | 467 | 92 | 0.09 / 139.06 | 6 | 6 |
2 | 7 | 2007.72 | 40 | 14.76 | 3203 | 1891 | 1.98 / 140.95 | 6 | 58 |
3 | 13 | 1839.72 | 20 | 14.76 | 3009 | 888 | 2.87 / 141.84 | 5 | 64 |
4 | 13 | 1284.44 | 20 | 14.88 | 2166 | 645 | 3.52 / 142.48 | 5 | 71 |
5 | 13 | 542.48 | 20 | 15.06 | 1124 | 339 | 3.85 / 142.82 | 5 | 75 |
6 | 13 | 121.64 | 20 | 15.18 | 520 | 158 | 4.01 / 142.98 | 5 | 69 |
7 | 8 | 0.16 | 272 | 15.17 | 312 | 1287 | 5.30 / 144.26 | 5 | 136 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 13 | 15.19 | 487 | 96 | 0.10 / 133.87 | 6 | 6 |
2 | 7 | 2010.48 | 40 | 14.76 | 3193 | 1885 | 1.98 / 135.75 | 6 | 59 |
3 | 13 | 1777.40 | 20 | 14.79 | 2878 | 851 | 2.83 / 136.61 | 5 | 64 |
4 | 13 | 1127.20 | 20 | 14.91 | 1952 | 582 | 3.41 / 137.19 | 5 | 72 |
5 | 13 | 572.36 | 20 | 15.05 | 1137 | 342 | 3.76 / 137.53 | 5 | 65 |
6 | 13 | 102.32 | 20 | 15.19 | 484 | 147 | 3.90 / 137.68 | 5 | 69 |
7 | 13 | 31.84 | 20 | 15.21 | 367 | 112 | 4.02 / 137.79 | 5 | 74 |
8 | 8 | -0.04 | 253 | 15.17 | 306 | 1174 | 5.19 / 138.96 | 5 | 139 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 13 | 15.19 | 483 | 95 | 0.10 / 128.66 | 6 | 6 |
2 | 7 | 2003.52 | 41 | 14.77 | 3198 | 1937 | 2.03 / 130.60 | 6 | 58 |
3 | 13 | 1734.76 | 20 | 14.78 | 2858 | 845 | 2.88 / 131.44 | 5 | 66 |
4 | 13 | 1218.72 | 20 | 14.88 | 2080 | 619 | 3.50 / 132.06 | 5 | 71 |
5 | 13 | 544.00 | 20 | 15.06 | 1108 | 334 | 3.83 / 132.39 | 5 | 72 |
6 | 13 | 80.00 | 20 | 15.20 | 447 | 136 | 3.97 / 132.53 | 5 | 72 |
7 | 8 | 0.16 | 267 | 15.17 | 307 | 1243 | 5.21 / 133.77 | 5 | 131 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 13 | 15.20 | 471 | 93 | 0.09 / 123.35 | 6 | 6 |
2 | 7 | 2006.24 | 40 | 14.78 | 3188 | 1885 | 1.98 / 125.24 | 6 | 58 |
3 | 13 | 1836.56 | 20 | 14.78 | 2990 | 884 | 2.86 / 126.12 | 5 | 64 |
4 | 13 | 1280.76 | 20 | 14.87 | 2145 | 638 | 3.50 / 126.76 | 5 | 70 |
5 | 13 | 671.40 | 20 | 15.03 | 1293 | 389 | 3.89 / 127.15 | 5 | 77 |
6 | 13 | 123.72 | 20 | 15.19 | 519 | 158 | 4.05 / 127.31 | 5 | 73 |
7 | 13 | 54.56 | 20 | 15.21 | 407 | 124 | 4.17 / 127.43 | 5 | 76 |
8 | 8 | 0.00 | 246 | 15.17 | 304 | 1134 | 5.30 / 128.56 | 5 | 138 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 13 | 15.21 | 469 | 93 | 0.09 / 118.13 | 6 | 6 |
2 | 7 | 2008.92 | 41 | 14.76 | 3217 | 1947 | 2.04 / 120.08 | 6 | 59 |
3 | 13 | 1805.96 | 20 | 14.78 | 2939 | 869 | 2.91 / 120.95 | 5 | 65 |
4 | 13 | 1181.04 | 20 | 14.90 | 2007 | 598 | 3.51 / 121.55 | 5 | 71 |
5 | 13 | 556.96 | 20 | 15.07 | 1138 | 343 | 3.85 / 121.89 | 5 | 78 |
6 | 13 | 170.68 | 20 | 15.18 | 593 | 180 | 4.03 / 122.07 | 5 | 76 |
7 | 8 | 0.36 | 259 | 15.19 | 303 | 1192 | 5.22 / 123.26 | 5 | 138 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 13 | 15.21 | 464 | 92 | 0.09 / 112.91 | 6 | 6 |
2 | 7 | 2008.44 | 40 | 14.77 | 3230 | 1908 | 2.00 / 114.82 | 6 | 59 |
3 | 13 | 1876.88 | 20 | 14.78 | 3047 | 901 | 2.90 / 115.72 | 5 | 63 |
4 | 13 | 1202.28 | 20 | 14.89 | 2084 | 621 | 3.52 / 116.34 | 5 | 76 |
5 | 13 | 535.88 | 20 | 15.08 | 1130 | 341 | 3.86 / 116.68 | 5 | 78 |
6 | 13 | 181.60 | 20 | 15.18 | 618 | 188 | 4.05 / 116.87 | 5 | 75 |
7 | 8 | 0.00 | 257 | 15.20 | 300 | 1172 | 5.22 / 118.04 | 5 | 138 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 13 | 15.22 | 469 | 93 | 0.09 / 107.67 | 6 | 6 |
2 | 7 | 2002.52 | 40 | 14.77 | 3247 | 1918 | 2.01 / 109.58 | 6 | 58 |
3 | 13 | 1799.68 | 20 | 14.78 | 2981 | 881 | 2.89 / 110.47 | 5 | 64 |
4 | 13 | 1207.16 | 20 | 14.90 | 2126 | 634 | 3.53 / 111.10 | 5 | 75 |
5 | 13 | 547.16 | 20 | 15.08 | 1147 | 346 | 3.87 / 111.45 | 5 | 77 |
6 | 13 | 163.64 | 20 | 15.19 | 606 | 184 | 4.06 / 111.63 | 5 | 70 |
7 | 8 | 0.08 | 257 | 15.20 | 304 | 1188 | 5.24 / 112.82 | 5 | 139 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 13 | 15.20 | 480 | 95 | 0.09 / 102.37 | 6 | 6 |
2 | 7 | 2009.08 | 40 | 14.79 | 3211 | 1900 | 1.99 / 104.27 | 6 | 55 |
3 | 13 | 1976.76 | 20 | 14.76 | 3174 | 937 | 2.93 / 105.21 | 5 | 59 |
4 | 13 | 1311.80 | 20 | 14.88 | 2230 | 664 | 3.60 / 105.87 | 5 | 73 |
5 | 13 | 568.88 | 20 | 15.08 | 1185 | 357 | 3.95 / 106.23 | 5 | 78 |
6 | 13 | 152.32 | 20 | 15.20 | 573 | 174 | 4.13 / 106.40 | 5 | 71 |
7 | 8 | 0.24 | 257 | 15.21 | 300 | 1173 | 5.30 / 107.57 | 5 | 131 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 13 | 15.20 | 478 | 94 | 0.09 / 97.16 | 6 | 6 |
2 | 7 | 2007.48 | 40 | 14.78 | 3223 | 1905 | 2.00 / 99.07 | 6 | 56 |
3 | 13 | 1837.56 | 20 | 14.80 | 3008 | 890 | 2.89 / 99.96 | 5 | 62 |
4 | 13 | 1170.68 | 20 | 14.91 | 2060 | 614 | 3.50 / 100.57 | 5 | 77 |
5 | 13 | 509.68 | 20 | 15.09 | 1103 | 333 | 3.84 / 100.90 | 5 | 82 |
6 | 13 | 82.48 | 20 | 15.22 | 473 | 144 | 3.98 / 101.05 | 5 | 75 |
7 | 8 | 0.00 | 259 | 15.19 | 312 | 1227 | 5.21 / 102.27 | 5 | 129 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 13 | 15.21 | 494 | 98 | 0.10 / 91.75 | 6 | 6 |
2 | 7 | 2009.16 | 40 | 14.78 | 3265 | 1930 | 2.03 / 93.68 | 6 | 56 |
3 | 13 | 1976.16 | 20 | 14.77 | 3222 | 952 | 2.98 / 94.63 | 5 | 60 |
4 | 13 | 1254.80 | 20 | 14.90 | 2195 | 654 | 3.63 / 95.28 | 5 | 75 |
5 | 13 | 583.84 | 20 | 15.06 | 1235 | 372 | 4.01 / 95.66 | 5 | 82 |
6 | 13 | 76.44 | 20 | 15.22 | 460 | 140 | 4.15 / 95.80 | 5 | 75 |
7 | 13 | 22.88 | 20 | 15.24 | 369 | 112 | 4.26 / 95.91 | 5 | 74 |
8 | 8 | 0.16 | 242 | 15.19 | 315 | 1158 | 5.42 / 97.07 | 5 | 132 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 13 | 15.20 | 475 | 94 | 0.09 / 86.41 | 6 | 6 |
2 | 7 | 2004.40 | 40 | 14.78 | 3273 | 1935 | 2.03 / 88.34 | 6 | 56 |
3 | 13 | 1871.20 | 20 | 14.81 | 3055 | 905 | 2.93 / 89.25 | 5 | 61 |
4 | 13 | 1167.40 | 20 | 14.92 | 2050 | 612 | 3.55 / 89.86 | 5 | 74 |
5 | 13 | 575.68 | 20 | 15.07 | 1208 | 364 | 3.91 / 90.22 | 5 | 82 |
6 | 13 | 68.08 | 20 | 15.23 | 444 | 135 | 4.04 / 90.36 | 5 | 75 |
7 | 13 | 20.80 | 20 | 15.24 | 359 | 109 | 4.15 / 90.47 | 5 | 74 |
8 | 8 | 0.00 | 242 | 15.19 | 321 | 1180 | 5.33 / 91.65 | 5 | 130 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 13 | 15.21 | 487 | 96 | 0.10 / 81.04 | 6 | 6 |
2 | 7 | 2004.64 | 40 | 14.80 | 3252 | 1925 | 2.02 / 82.96 | 6 | 58 |
3 | 13 | 1971.64 | 20 | 14.77 | 3177 | 938 | 2.96 / 83.90 | 5 | 61 |
4 | 13 | 1163.32 | 20 | 14.92 | 2084 | 622 | 3.58 / 84.53 | 5 | 78 |
5 | 13 | 569.96 | 20 | 15.07 | 1201 | 362 | 3.94 / 84.89 | 5 | 84 |
6 | 13 | 62.92 | 20 | 15.23 | 435 | 133 | 4.08 / 85.02 | 5 | 77 |
7 | 13 | 34.04 | 20 | 15.23 | 384 | 117 | 4.19 / 85.14 | 5 | 77 |
8 | 8 | 0.08 | 244 | 15.19 | 318 | 1179 | 5.37 / 86.32 | 5 | 134 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 13 | 15.22 | 461 | 91 | 0.09 / 75.72 | 6 | 6 |
2 | 7 | 2003.80 | 40 | 14.79 | 3261 | 1929 | 2.02 / 77.65 | 6 | 59 |
3 | 13 | 1764.64 | 20 | 14.82 | 2934 | 870 | 2.89 / 78.52 | 5 | 64 |
4 | 13 | 1180.28 | 20 | 14.92 | 2090 | 624 | 3.51 / 79.14 | 5 | 77 |
5 | 13 | 553.40 | 20 | 15.08 | 1196 | 361 | 3.87 / 79.50 | 5 | 84 |
6 | 13 | 80.20 | 20 | 15.23 | 461 | 140 | 4.01 / 79.64 | 5 | 78 |
7 | 13 | 22.36 | 20 | 15.24 | 363 | 111 | 4.13 / 79.75 | 5 | 76 |
8 | 8 | 0.04 | 246 | 15.19 | 319 | 1192 | 5.32 / 80.94 | 5 | 135 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 13 | 15.22 | 494 | 98 | 0.10 / 70.47 | 6 | 6 |
2 | 7 | 2008.12 | 40 | 14.81 | 3225 | 1910 | 2.01 / 72.38 | 6 | 57 |
3 | 13 | 1739.40 | 20 | 14.83 | 2914 | 864 | 2.87 / 73.24 | 5 | 65 |
4 | 13 | 1243.04 | 20 | 14.90 | 2169 | 646 | 3.52 / 73.89 | 5 | 74 |
5 | 13 | 531.32 | 20 | 15.09 | 1148 | 346 | 3.87 / 74.23 | 5 | 83 |
6 | 13 | 62.56 | 20 | 15.24 | 428 | 130 | 4.00 / 74.36 | 5 | 77 |
7 | 13 | 16.00 | 20 | 15.25 | 348 | 106 | 4.10 / 74.47 | 5 | 75 |
8 | 8 | 0.08 | 240 | 15.20 | 317 | 1156 | 5.26 / 75.63 | 5 | 135 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 13 | 15.21 | 498 | 98 | 0.10 / 65.05 | 6 | 6 |
2 | 7 | 2006.36 | 40 | 14.81 | 3246 | 1923 | 2.02 / 66.97 | 6 | 58 |
3 | 13 | 1973.84 | 20 | 14.78 | 3236 | 957 | 2.98 / 67.93 | 5 | 61 |
4 | 13 | 1166.72 | 20 | 14.94 | 2070 | 619 | 3.60 / 68.55 | 5 | 77 |
5 | 13 | 571.92 | 20 | 15.08 | 1207 | 364 | 3.96 / 68.91 | 5 | 83 |
6 | 13 | 62.76 | 20 | 15.24 | 442 | 135 | 4.10 / 69.04 | 5 | 78 |
7 | 13 | 15.48 | 20 | 15.24 | 365 | 111 | 4.21 / 69.16 | 5 | 76 |
8 | 8 | 0.00 | 246 | 15.20 | 324 | 1212 | 5.42 / 70.37 | 5 | 132 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 13 | 15.21 | 480 | 95 | 0.09 / 59.79 | 6 | 6 |
2 | 7 | 2002.24 | 40 | 14.82 | 3248 | 1925 | 2.02 / 61.71 | 6 | 57 |
3 | 13 | 1797.64 | 20 | 14.83 | 2998 | 889 | 2.91 / 62.60 | 5 | 65 |
4 | 13 | 1044.48 | 20 | 14.96 | 1890 | 565 | 3.48 / 63.17 | 5 | 78 |
5 | 13 | 531.28 | 20 | 15.10 | 1140 | 344 | 3.82 / 63.51 | 5 | 83 |
6 | 13 | 42.72 | 20 | 15.24 | 412 | 126 | 3.94 / 63.64 | 5 | 79 |
7 | 13 | 16.32 | 20 | 15.25 | 359 | 109 | 4.05 / 63.75 | 5 | 78 |
8 | 8 | 0.08 | 244 | 15.20 | 324 | 1202 | 5.26 / 64.95 | 5 | 131 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 13 | 15.21 | 494 | 98 | 0.10 / 54.42 | 6 | 6 |
2 | 7 | 2007.32 | 40 | 14.82 | 3242 | 1922 | 2.02 / 56.34 | 6 | 57 |
3 | 13 | 1837.56 | 20 | 14.82 | 3054 | 905 | 2.92 / 57.25 | 5 | 65 |
4 | 13 | 1289.68 | 20 | 14.91 | 2223 | 663 | 3.59 / 57.91 | 5 | 74 |
5 | 13 | 457.72 | 20 | 15.13 | 1035 | 313 | 3.90 / 58.22 | 5 | 81 |
6 | 13 | 66.64 | 20 | 15.24 | 451 | 137 | 4.04 / 58.36 | 5 | 78 |
7 | 13 | 18.28 | 20 | 15.25 | 364 | 111 | 4.15 / 58.47 | 5 | 78 |
8 | 8 | 0.08 | 246 | 15.20 | 327 | 1223 | 5.37 / 59.69 | 5 | 131 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 13 | 15.21 | 498 | 98 | 0.10 / 49.19 | 6 | 6 |
2 | 7 | 2003.36 | 40 | 14.81 | 3253 | 1927 | 2.03 / 51.12 | 6 | 58 |
3 | 13 | 1728.80 | 20 | 14.85 | 2880 | 855 | 2.88 / 51.97 | 5 | 66 |
4 | 13 | 1106.68 | 20 | 14.96 | 1987 | 595 | 3.48 / 52.57 | 5 | 78 |
5 | 13 | 440.76 | 20 | 15.12 | 1011 | 306 | 3.78 / 52.87 | 5 | 82 |
6 | 13 | 57.12 | 20 | 15.25 | 433 | 132 | 3.91 / 53.01 | 5 | 79 |
7 | 13 | 16.40 | 20 | 15.25 | 358 | 109 | 4.02 / 53.12 | 5 | 80 |
8 | 8 | 0.04 | 244 | 15.20 | 325 | 1205 | 5.23 / 54.32 | 5 | 129 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 13 | 15.22 | 494 | 98 | 0.10 / 43.86 | 6 | 6 |
2 | 7 | 2003.40 | 40 | 14.83 | 3223 | 1912 | 2.01 / 45.77 | 6 | 58 |
3 | 13 | 1764.80 | 20 | 14.86 | 2867 | 852 | 2.86 / 46.62 | 5 | 64 |
4 | 13 | 1270.44 | 20 | 14.93 | 2181 | 651 | 3.51 / 47.27 | 5 | 76 |
5 | 13 | 543.96 | 20 | 15.10 | 1144 | 345 | 3.86 / 47.62 | 5 | 86 |
6 | 13 | 74.52 | 20 | 15.24 | 452 | 138 | 4.00 / 47.75 | 5 | 83 |
7 | 13 | 10.20 | 20 | 15.26 | 344 | 105 | 4.10 / 47.86 | 5 | 82 |
8 | 8 | -0.04 | 250 | 15.20 | 325 | 1235 | 5.34 / 49.09 | 5 | 138 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 13 | 15.23 | 468 | 93 | 0.09 / 38.56 | 6 | 6 |
2 | 7 | 2003.44 | 41 | 14.82 | 3276 | 1991 | 2.08 / 40.55 | 6 | 60 |
3 | 13 | 1833.12 | 20 | 14.85 | 2998 | 890 | 2.97 / 41.45 | 5 | 65 |
4 | 13 | 1128.76 | 20 | 14.95 | 2029 | 607 | 3.58 / 42.05 | 5 | 79 |
5 | 13 | 468.76 | 20 | 15.13 | 1049 | 317 | 3.90 / 42.37 | 5 | 86 |
6 | 13 | 48.56 | 20 | 15.25 | 415 | 127 | 4.02 / 42.50 | 5 | 82 |
7 | 8 | 0.16 | 259 | 15.22 | 320 | 1261 | 5.29 / 43.76 | 5 | 134 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 13 | 15.23 | 469 | 93 | 0.09 / 33.30 | 6 | 6 |
2 | 7 | 2003.72 | 40 | 14.83 | 3237 | 1920 | 2.01 / 35.22 | 6 | 60 |
3 | 13 | 1802.60 | 20 | 14.85 | 2994 | 889 | 2.90 / 36.11 | 5 | 66 |
4 | 13 | 1176.84 | 20 | 14.95 | 2071 | 619 | 3.52 / 36.73 | 5 | 79 |
5 | 13 | 567.64 | 20 | 15.10 | 1188 | 359 | 3.88 / 37.09 | 5 | 85 |
6 | 13 | 93.12 | 20 | 15.25 | 486 | 148 | 4.03 / 37.24 | 5 | 80 |
7 | 8 | 0.12 | 257 | 15.22 | 316 | 1236 | 5.26 / 38.47 | 5 | 141 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 13 | 15.24 | 477 | 95 | 0.09 / 28.04 | 6 | 6 |
2 | 7 | 2006.44 | 40 | 14.83 | 3269 | 1939 | 2.03 / 29.98 | 6 | 61 |
3 | 13 | 1839.92 | 20 | 14.84 | 3010 | 893 | 2.93 / 30.87 | 5 | 65 |
4 | 13 | 1155.64 | 20 | 14.96 | 2045 | 612 | 3.54 / 31.48 | 5 | 80 |
5 | 13 | 562.48 | 20 | 15.10 | 1194 | 361 | 3.90 / 31.84 | 5 | 84 |
6 | 13 | 60.88 | 20 | 15.26 | 426 | 130 | 4.03 / 31.97 | 5 | 76 |
7 | 8 | 0.00 | 257 | 15.22 | 316 | 1236 | 5.27 / 33.21 | 5 | 134 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 13 | 15.25 | 483 | 96 | 0.10 / 22.60 | 6 | 6 |
2 | 7 | 2004.20 | 40 | 14.84 | 3238 | 1922 | 2.02 / 24.52 | 6 | 58 |
3 | 13 | 1973.64 | 20 | 14.81 | 3230 | 957 | 2.97 / 25.48 | 5 | 63 |
4 | 13 | 1285.60 | 20 | 14.93 | 2236 | 668 | 3.64 / 26.14 | 5 | 77 |
5 | 13 | 673.16 | 20 | 15.07 | 1362 | 411 | 4.05 / 26.55 | 5 | 82 |
6 | 13 | 162.40 | 20 | 15.23 | 608 | 185 | 4.24 / 26.74 | 5 | 78 |
7 | 8 | 0.16 | 253 | 15.23 | 312 | 1202 | 5.44 / 27.94 | 5 | 136 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 13 | 15.24 | 488 | 97 | 0.10 / 17.41 | 6 | 6 |
2 | 7 | 2007.68 | 40 | 14.84 | 3255 | 1932 | 2.03 / 19.34 | 6 | 59 |
3 | 13 | 1698.00 | 20 | 14.88 | 2820 | 839 | 2.87 / 20.18 | 5 | 66 |
4 | 13 | 1182.20 | 20 | 14.95 | 2077 | 621 | 3.49 / 20.80 | 5 | 75 |
5 | 13 | 506.20 | 20 | 15.13 | 1111 | 336 | 3.83 / 21.13 | 5 | 80 |
6 | 13 | 117.48 | 20 | 15.25 | 534 | 163 | 3.99 / 21.30 | 5 | 74 |
7 | 8 | 0.08 | 250 | 15.24 | 316 | 1204 | 5.19 / 22.50 | 5 | 129 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 13 | 15.24 | 473 | 94 | 0.09 / 12.18 | 6 | 6 |
2 | 7 | 2006.20 | 40 | 14.86 | 3221 | 1915 | 2.01 / 14.09 | 6 | 58 |
3 | 13 | 1973.24 | 20 | 14.83 | 3222 | 956 | 2.96 / 15.05 | 5 | 61 |
4 | 13 | 1149.32 | 20 | 14.97 | 2028 | 607 | 3.57 / 15.66 | 5 | 75 |
5 | 13 | 496.00 | 20 | 15.14 | 1058 | 320 | 3.89 / 15.98 | 5 | 81 |
6 | 13 | 69.16 | 20 | 15.26 | 432 | 132 | 4.02 / 16.11 | 5 | 76 |
7 | 8 | 1.04 | 257 | 15.23 | 307 | 1202 | 5.22 / 17.31 | 5 | 131 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 9 | 15.23 | 466 | 64 | 0.06 / 6.83 | 6 | 6 |
2 | 10 | 1503.04 | 4 | 15.02 | 2583 | 155 | 0.22 / 6.99 | 5 | 41 |
3 | 3 | 1575.48 | 2 | 15.06 | 2712 | 82 | 0.30 / 7.07 | 5 | 40 |
4 | 7 | 2004.00 | 40 | 14.84 | 3255 | 1932 | 2.23 / 9.00 | 40 | 59 |
5 | 13 | 1731.72 | 20 | 14.88 | 2861 | 851 | 3.08 / 9.85 | 5 | 66 |
6 | 13 | 1077.40 | 20 | 14.99 | 1905 | 571 | 3.66 / 10.42 | 5 | 78 |
7 | 13 | 487.84 | 20 | 15.14 | 1060 | 321 | 3.98 / 10.75 | 5 | 81 |
8 | 13 | 100.64 | 20 | 15.26 | 480 | 146 | 4.12 / 10.89 | 5 | 74 |
9 | 8 | 0.04 | 255 | 15.23 | 307 | 1192 | 5.32 / 12.08 | 5 | 143 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 20 | 15.39 | 466 | 143 | 0.14 / 1.96 | 6 | 9 |
2 | 3 | 1161.16 | -5 | 15.60 | 0 | 0 | 0.00 / 1.96 | 6 | 9 |
3 | 7 | 1875.60 | 41 | 14.90 | 3012 | 1840 | 1.98 / 3.80 | 9 | 59 |
4 | 13 | 1742.48 | 20 | 14.89 | 2843 | 847 | 2.83 / 4.65 | 5 | 64 |
5 | 13 | 992.36 | 20 | 15.01 | 1804 | 542 | 3.37 / 5.19 | 5 | 78 |
6 | 13 | 382.24 | 20 | 15.17 | 922 | 280 | 3.65 / 5.47 | 5 | 79 |
7 | 13 | 185.76 | 20 | 15.22 | 607 | 185 | 3.84 / 5.65 | 5 | 76 |
8 | 8 | 0.12 | 248 | 15.23 | 295 | 1114 | 4.95 / 6.77 | 5 | 132 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 131.84 | 20 | 15.57 | 515 | 160 | 0.16 / 0.16 | 6 | 16 |
2 | 7 | 142.04 | 40 | 15.54 | 524 | 326 | 0.49 / 0.49 | 16 | 24 |
3 | 13 | 129.56 | 20 | 15.53 | 501 | 156 | 0.64 / 0.64 | 6 | 24 |
4 | 13 | 64.56 | 20 | 15.52 | 387 | 120 | 0.76 / 0.76 | 6 | 27 |
5 | 8 | 0.08 | 244 | 15.47 | 280 | 1057 | 1.82 / 1.82 | 6 | 135 |
Average= | 1.82 (KJ/cycle) |