SIO Argo Site:
Pump Diagnostics Page   



Serial= 7494 WMO= 4903224

Return

←PreviousNext→

Cycle 182 GMT 12/11/2024 4:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 30 14.80 441 196 0.20 / 968.92 6 12
2 7 2003.84 40 14.40 3315 1909 2.11 / 970.83 12 56
3 13 1907.64 20 14.37 3165 910 3.01 / 971.74 5 63
4 13 1259.36 20 14.43 2255 651 3.67 / 972.39 5 76
5 13 827.88 20 14.52 1617 470 4.14 / 972.86 5 83
6 13 73.88 20 14.81 445 132 4.27 / 972.99 6 77
7 13 18.44 20 14.83 339 101 4.37 / 973.09 6 73
8 8 0.00 249 14.78 304 1119 5.49 / 974.21 6 156
Average= 11.88
(KJ/cycle)

Cycle 181 GMT 2/11/2024 6:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 30 14.79 449 199 0.20 / 963.49 6 12
2 7 2008.84 40 14.40 3317 1911 2.11 / 965.40 12 58
3 13 1811.88 20 14.39 3061 881 2.99 / 966.28 5 64
4 13 1290.00 20 14.43 2302 664 3.66 / 966.95 5 76
5 13 747.68 20 14.55 1496 435 4.09 / 967.38 5 83
6 13 84.80 20 14.80 470 139 4.23 / 967.52 6 82
7 8 -0.08 265 14.78 306 1199 5.43 / 968.72 6 136
Average= 11.96
(KJ/cycle)

Cycle 180 GMT 23/10/2024 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 30 14.80 460 204 0.20 / 957.96 6 10
2 7 2012.28 40 14.40 3324 1915 2.12 / 959.88 10 56
3 13 1922.80 20 14.37 3216 924 3.04 / 960.80 5 63
4 13 1203.24 20 14.44 2187 632 3.67 / 961.43 5 77
5 13 874.16 20 14.50 1688 490 4.16 / 961.92 5 83
6 13 83.16 20 14.80 471 139 4.30 / 962.06 6 81
7 13 21.88 20 14.82 354 105 4.41 / 962.17 6 76
8 8 -0.04 246 14.77 310 1126 5.53 / 963.29 6 135
Average= 12.04
(KJ/cycle)

Cycle 179 GMT 13/10/2024 11:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 30 14.81 444 197 0.20 / 952.51 6 10
2 7 2004.16 41 14.40 3321 1961 2.16 / 954.47 10 56
3 13 1808.40 20 14.39 3044 876 3.03 / 955.34 5 67
4 13 1268.72 20 14.44 2259 652 3.69 / 956.00 5 78
5 13 638.56 20 14.59 1349 394 4.08 / 956.39 5 83
6 13 90.88 20 14.79 495 146 4.23 / 956.54 6 81
7 8 0.08 265 14.77 312 1221 5.45 / 957.76 6 142
Average= 12.12
(KJ/cycle)

Cycle 178 GMT 3/10/2024 13:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 30 14.81 444 197 0.20 / 946.99 6 11
2 7 2006.64 40 14.40 3328 1917 2.11 / 948.91 11 58
3 13 1913.40 20 14.37 3188 916 3.03 / 949.82 5 62
4 13 1360.60 20 14.41 2405 693 3.72 / 950.51 5 75
5 13 806.80 20 14.53 1603 466 4.19 / 950.98 5 82
6 13 63.28 20 14.81 432 128 4.32 / 951.11 6 80
7 13 18.08 20 14.82 339 100 4.42 / 951.21 6 73
8 8 -0.04 246 14.78 303 1102 5.52 / 952.31 6 140
Average= 12.21
(KJ/cycle)

Cycle 177 GMT 23/ 9/2024 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 30 14.80 448 199 0.20 / 941.58 6 12
2 7 2007.64 40 14.40 3314 1909 2.11 / 943.49 12 56
3 13 1922.92 20 14.38 3196 919 3.03 / 944.41 5 63
4 13 1300.80 20 14.42 2314 667 3.69 / 945.08 5 75
5 13 653.16 20 14.59 1364 398 4.09 / 945.47 5 86
6 13 63.04 20 14.81 425 126 4.22 / 945.60 6 77
7 8 0.04 268 14.78 301 1192 5.41 / 946.79 6 140
Average= 12.30
(KJ/cycle)

Cycle 176 GMT 13/ 9/2024 18:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 30 14.79 449 199 0.20 / 936.03 6 12
2 7 2007.36 40 14.40 3314 1909 2.11 / 937.94 12 56
3 13 1917.48 20 14.37 3189 917 3.02 / 938.85 5 62
4 13 1474.08 20 14.39 2576 741 3.77 / 939.59 5 71
5 13 792.48 20 14.54 1555 452 4.22 / 940.05 5 84
6 13 101.20 20 14.79 500 148 4.37 / 940.19 6 80
7 8 0.04 267 14.77 301 1187 5.55 / 941.38 6 140
Average= 12.39
(KJ/cycle)

Cycle 175 GMT 3/ 9/2024 21:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 30 14.80 434 193 0.19 / 930.35 6 13
2 7 2006.44 40 14.42 3308 1908 2.10 / 932.26 13 56
3 13 1910.12 20 14.39 3182 916 3.02 / 933.17 5 65
4 13 1372.52 20 14.41 2425 699 3.72 / 933.87 5 74
5 13 939.56 20 14.49 1781 516 4.23 / 934.39 5 82
6 13 249.32 20 14.72 752 221 4.45 / 934.61 5 87
7 13 62.32 20 14.79 416 123 4.58 / 934.73 6 78
8 8 -0.08 248 14.77 299 1095 5.67 / 935.83 6 135
Average= 12.48
(KJ/cycle)

Cycle 174 GMT 25/ 8/2024 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 30 14.80 442 196 0.20 / 924.90 6 12
2 7 2012.16 40 14.40 3320 1912 2.11 / 926.82 12 55
3 13 1918.16 20 14.38 3204 921 3.03 / 927.74 5 60
4 13 1384.48 20 14.41 2446 705 3.73 / 928.44 5 72
5 13 639.84 20 14.59 1334 389 4.12 / 928.83 5 83
6 13 98.84 20 14.79 493 146 4.27 / 928.98 6 79
7 8 0.00 265 14.77 301 1178 5.45 / 930.16 6 131
Average= 12.57
(KJ/cycle)

Cycle 173 GMT 15/ 8/2024 2:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 30 14.80 455 202 0.20 / 919.40 6 11
2 7 2012.36 40 14.41 3316 1911 2.11 / 921.31 11 56
3 13 1924.48 20 14.38 3217 925 3.04 / 922.24 5 61
4 13 1310.40 20 14.42 2340 675 3.71 / 922.91 5 74
5 13 880.16 20 14.50 1700 493 4.21 / 923.41 5 84
6 13 92.56 20 14.79 477 141 4.35 / 923.55 6 77
7 8 0.04 268 14.78 293 1161 5.51 / 924.71 6 138
Average= 12.67
(KJ/cycle)

Cycle 172 GMT 5/ 8/2024 4:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 30 14.78 437 194 0.19 / 914.05 6 11
2 7 2003.00 40 14.41 3294 1899 2.09 / 915.94 11 55
3 13 1713.76 20 14.41 2927 844 2.94 / 916.79 5 66
4 13 1301.12 20 14.42 2332 673 3.61 / 917.46 5 74
5 13 653.00 20 14.58 1367 399 4.01 / 917.86 5 85
6 13 92.08 20 14.79 481 142 4.15 / 918.00 6 80
7 8 0.08 268 14.77 303 1199 5.35 / 919.20 6 143
Average= 12.77
(KJ/cycle)

Cycle 171 GMT 26/ 7/2024 7:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 30 14.80 435 193 0.19 / 908.77 6 10
2 7 2003.20 40 14.42 3299 1903 2.10 / 910.67 10 56
3 13 1712.40 20 14.41 2937 846 2.94 / 911.52 5 65
4 13 1281.16 20 14.43 2297 663 3.61 / 912.18 5 74
5 13 532.12 20 14.62 1187 347 3.95 / 912.53 5 83
6 13 97.44 20 14.78 483 143 4.10 / 912.67 6 77
7 13 24.64 20 14.80 341 101 4.20 / 912.77 6 71
8 8 -0.12 246 14.76 297 1078 5.27 / 913.85 6 130
Average= 12.87
(KJ/cycle)

Cycle 170 GMT 16/ 7/2024 9:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 30 14.78 432 192 0.19 / 903.39 6 12
2 7 2004.20 40 14.42 3314 1912 2.10 / 905.31 12 56
3 13 1918.92 20 14.41 3172 914 3.02 / 906.22 5 62
4 13 1276.84 20 14.42 2289 660 3.68 / 906.88 5 75
5 13 621.68 20 14.58 1300 379 4.06 / 907.26 5 84
6 13 92.04 20 14.79 467 138 4.19 / 907.40 6 75
7 13 22.68 20 14.81 331 98 4.29 / 907.50 6 68
8 8 -0.04 249 14.77 294 1081 5.37 / 908.58 6 144
Average= 12.98
(KJ/cycle)

Cycle 169 GMT 6/ 7/2024 12:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 30 14.80 435 193 0.19 / 898.16 6 11
2 7 2002.92 40 14.42 3300 1903 2.10 / 900.06 11 57
3 13 1811.00 20 14.41 3029 873 2.97 / 900.93 5 66
4 13 1179.96 20 14.46 2142 619 3.59 / 901.55 5 76
5 13 557.72 20 14.61 1217 356 3.94 / 901.91 5 84
6 13 64.60 20 14.78 418 124 4.07 / 902.03 6 73
7 8 0.04 268 14.75 296 1170 5.24 / 903.20 6 143
Average= 13.09
(KJ/cycle)

Cycle 168 GMT 26/ 6/2024 14:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 30 14.79 434 193 0.19 / 892.68 6 11
2 7 2008.32 41 14.41 3327 1966 2.16 / 894.65 11 56
3 13 1917.96 20 14.40 3163 911 3.07 / 895.56 5 62
4 13 1361.20 20 14.42 2396 691 3.76 / 896.25 5 75
5 13 707.04 20 14.56 1444 420 4.18 / 896.67 5 82
6 13 83.80 20 14.79 454 134 4.31 / 896.81 6 74
7 8 0.00 265 14.77 296 1159 5.47 / 897.96 6 135
Average= 13.21
(KJ/cycle)

Cycle 167 GMT 16/ 6/2024 17:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 30 14.80 434 193 0.19 / 887.29 6 12
2 7 2011.76 40 14.42 3326 1918 2.11 / 889.21 12 56
3 13 1913.08 20 14.38 3200 920 3.03 / 890.13 5 61
4 13 1277.48 20 14.43 2303 665 3.70 / 890.79 5 75
5 13 644.48 20 14.58 1346 392 4.09 / 891.18 5 83
6 13 100.88 20 14.78 492 145 4.23 / 891.33 6 78
7 8 0.00 263 14.77 299 1161 5.40 / 892.49 6 134
Average= 13.32
(KJ/cycle)

Cycle 166 GMT 6/ 6/2024 19:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 30 14.80 444 197 0.20 / 881.93 6 10
2 7 2004.00 40 14.43 3305 1908 2.10 / 883.84 10 56
3 13 1909.20 20 14.40 3172 914 3.02 / 884.75 5 60
4 13 1184.68 20 14.47 2133 617 3.64 / 885.37 5 78
5 13 759.92 20 14.54 1517 441 4.08 / 885.81 5 83
6 13 98.16 20 14.78 477 141 4.22 / 885.95 6 78
7 8 0.04 265 14.77 292 1143 5.36 / 887.10 6 138
Average= 13.44
(KJ/cycle)

Cycle 165 GMT 27/ 5/2024 22: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 30 14.79 453 201 0.20 / 876.44 6 12
2 7 2004.76 40 14.42 3324 1917 2.12 / 878.36 12 58
3 13 1909.60 20 14.40 3184 917 3.04 / 879.27 5 62
4 13 1387.68 20 14.42 2452 707 3.74 / 879.98 5 72
5 13 747.80 20 14.55 1503 437 4.18 / 880.42 5 85
6 13 109.08 20 14.79 506 150 4.33 / 880.57 6 78
7 8 0.12 267 14.78 296 1168 5.50 / 881.73 6 138
Average= 13.57
(KJ/cycle)

Cycle 164 GMT 18/ 5/2024 0:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 30 14.80 432 192 0.19 / 871.19 6 11
2 7 2003.20 40 14.43 3303 1906 2.10 / 873.09 11 55
3 13 1707.16 20 14.43 2896 836 2.93 / 873.93 5 67
4 13 1289.64 20 14.45 2288 661 3.60 / 874.59 5 76
5 13 557.64 20 14.61 1219 356 3.95 / 874.95 5 85
6 13 110.56 20 14.78 506 150 4.10 / 875.10 6 79
7 8 0.12 263 14.77 294 1142 5.24 / 876.24 6 129
Average= 13.69
(KJ/cycle)

Cycle 163 GMT 8/ 5/2024 2:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 30 14.78 439 195 0.19 / 865.79 6 11
2 7 2004.80 40 14.42 3306 1907 2.10 / 867.70 11 56
3 13 1910.48 20 14.40 3172 914 3.02 / 868.61 5 60
4 13 1360.68 20 14.42 2395 691 3.71 / 869.30 5 73
5 13 699.44 20 14.57 1426 416 4.12 / 869.72 5 82
6 13 82.56 20 14.80 442 131 4.25 / 869.85 6 71
7 13 21.68 20 14.82 327 97 4.35 / 869.95 6 67
8 8 0.04 246 14.78 288 1047 5.40 / 870.99 6 137
Average= 13.83
(KJ/cycle)

Cycle 162 GMT 28/ 4/2024 5:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 30 14.80 453 201 0.20 / 860.34 6 14
2 7 2007.96 40 14.42 3310 1909 2.11 / 862.25 14 55
3 13 1714.20 20 14.42 2899 836 2.95 / 863.09 5 67
4 13 1517.40 20 14.39 2618 753 3.70 / 863.84 5 71
5 13 725.28 20 14.56 1456 424 4.12 / 864.27 5 85
6 13 156.80 20 14.76 587 173 4.30 / 864.44 6 80
7 8 0.00 265 14.77 296 1159 5.46 / 865.60 6 130
Average= 13.96
(KJ/cycle)

Cycle 161 GMT 18/ 4/2024 8: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 30 14.79 460 204 0.20 / 854.97 6 11
2 7 2003.52 40 14.43 3297 1903 2.11 / 856.87 11 58
3 13 1812.04 20 14.41 3050 879 2.99 / 857.75 5 63
4 13 1182.64 20 14.46 2147 621 3.61 / 858.37 5 75
5 13 854.28 20 14.51 1669 484 4.09 / 858.86 5 83
6 13 89.96 20 14.79 465 138 4.23 / 859.00 6 75
7 8 0.12 265 14.77 293 1147 5.38 / 860.14 6 131
Average= 14.10
(KJ/cycle)

Cycle 160 GMT 8/ 4/2024 10:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 30 14.79 444 197 0.20 / 849.50 6 12
2 7 2004.44 40 14.42 3306 1907 2.10 / 851.40 12 56
3 13 1908.56 20 14.39 3171 913 3.02 / 852.32 5 63
4 13 1357.16 20 14.43 2396 691 3.71 / 853.01 5 72
5 13 695.56 20 14.56 1432 417 4.13 / 853.42 5 82
6 13 72.44 20 14.80 438 130 4.25 / 853.55 6 71
7 13 42.60 20 14.81 376 111 4.37 / 853.66 6 68
8 8 0.00 248 14.76 301 1102 5.47 / 854.77 6 138
Average= 14.25
(KJ/cycle)

Cycle 159 GMT 29/ 3/2024 13: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 30 14.79 439 195 0.19 / 844.10 6 12
2 7 2007.96 40 14.42 3311 1910 2.10 / 846.01 12 57
3 13 1806.20 20 14.42 3034 875 2.98 / 846.88 5 64
4 13 1292.76 20 14.44 2297 663 3.64 / 847.55 5 75
5 13 756.84 20 14.54 1520 442 4.08 / 847.99 5 82
6 13 95.28 20 14.79 472 140 4.22 / 848.13 6 73
7 8 0.08 267 14.77 297 1171 5.40 / 849.30 6 136
Average= 14.39
(KJ/cycle)

Cycle 158 GMT 19/ 3/2024 15:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 30 14.80 436 194 0.19 / 838.68 6 12
2 7 2013.00 40 14.42 3316 1913 2.11 / 840.59 12 56
3 13 1923.88 20 14.38 3212 924 3.03 / 841.52 5 62
4 13 1373.68 20 14.42 2429 701 3.73 / 842.22 5 76
5 13 604.36 20 14.59 1296 378 4.11 / 842.60 5 83
6 13 85.76 20 14.80 456 135 4.24 / 842.73 6 73
7 13 22.00 20 14.82 334 99 4.34 / 842.83 6 67
8 8 0.08 246 14.77 295 1072 5.41 / 843.90 6 138
Average= 14.55
(KJ/cycle)

Cycle 157 GMT 9/ 3/2024 17:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 30 14.80 431 191 0.19 / 833.08 6 11
2 7 2003.48 41 14.43 3300 1952 2.14 / 835.04 11 56
3 13 1904.52 20 14.40 3169 913 3.06 / 835.95 5 63
4 13 1572.28 20 14.38 2689 773 3.83 / 836.72 5 72
5 13 788.64 20 14.53 1551 451 4.28 / 837.17 5 84
6 13 99.32 20 14.78 487 144 4.42 / 837.32 6 75
7 13 23.92 20 14.81 337 100 4.52 / 837.42 6 68
8 8 0.08 246 14.77 295 1072 5.60 / 838.49 6 141
Average= 14.71
(KJ/cycle)

Cycle 156 GMT 28/ 2/2024 20:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 30 14.79 442 196 0.20 / 827.68 6 15
2 7 2006.12 40 14.44 3311 1912 2.11 / 829.59 15 56
3 13 1908.84 20 14.42 3162 912 3.02 / 830.50 5 60
4 13 1288.64 20 14.44 2319 670 3.69 / 831.17 5 74
5 13 644.60 20 14.58 1343 392 4.08 / 831.57 5 84
6 13 95.16 20 14.79 477 141 4.22 / 831.71 6 77
7 13 25.56 20 14.81 346 102 4.33 / 831.81 6 70
8 8 0.04 246 14.77 298 1083 5.41 / 832.89 6 146
Average= 14.87
(KJ/cycle)

Cycle 155 GMT 18/ 2/2024 23: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 30 14.80 432 192 0.19 / 822.33 6 15
2 7 2006.52 40 14.44 3290 1900 2.09 / 824.23 15 57
3 13 1909.68 20 14.42 3160 911 3.00 / 825.14 5 61
4 13 1271.20 20 14.45 2275 657 3.66 / 825.79 5 73
5 13 640.52 20 14.59 1341 391 4.05 / 826.19 5 83
6 13 99.48 20 14.79 486 144 4.20 / 826.33 6 76
7 8 0.16 265 14.77 295 1155 5.35 / 827.48 6 134
Average= 15.05
(KJ/cycle)

Cycle 154 GMT 9/ 2/2024 1:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 30 14.79 443 197 0.20 / 816.90 6 11
2 7 2010.00 40 14.42 3315 1912 2.11 / 818.81 11 57
3 13 1918.52 20 14.40 3188 918 3.03 / 819.73 5 62
4 13 1274.60 20 14.45 2276 658 3.68 / 820.39 5 76
5 13 731.76 20 14.56 1478 430 4.11 / 820.82 5 82
6 13 84.48 20 14.79 464 137 4.25 / 820.96 6 73
7 13 22.40 20 14.82 334 99 4.35 / 821.05 6 66
8 8 0.04 246 14.77 297 1079 5.43 / 822.13 6 141
Average= 15.22
(KJ/cycle)

Cycle 153 GMT 30/ 1/2024 3:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 30 14.80 441 196 0.20 / 811.44 6 12
2 7 2005.92 40 14.44 3303 1908 2.10 / 813.35 12 58
3 13 1912.76 20 14.40 3175 914 3.02 / 814.26 5 61
4 13 1370.96 20 14.44 2406 695 3.71 / 814.96 5 77
5 13 705.28 20 14.56 1446 421 4.13 / 815.38 5 82
6 13 75.56 20 14.80 443 131 4.27 / 815.51 6 73
7 13 19.88 20 14.81 340 101 4.37 / 815.61 6 68
8 8 0.00 246 14.77 301 1094 5.46 / 816.70 6 132
Average= 15.41
(KJ/cycle)

Cycle 152 GMT 20/ 1/2024 6:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 30 14.80 433 192 0.19 / 806.04 6 11
2 7 2002.84 40 14.44 3295 1903 2.10 / 807.95 11 57
3 13 1907.04 20 14.42 3180 917 3.01 / 808.86 5 63
4 13 1265.84 20 14.46 2274 658 3.67 / 809.52 5 77
5 13 621.08 20 14.60 1319 385 4.06 / 809.91 5 85
6 13 86.56 20 14.80 460 136 4.19 / 810.04 6 76
7 13 47.52 20 14.81 384 114 4.31 / 810.16 6 73
8 8 0.00 249 14.77 296 1089 5.39 / 811.24 6 136
Average= 15.60
(KJ/cycle)

Cycle 151 GMT 10/ 1/2024 8:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 30 14.79 434 193 0.19 / 800.57 6 12
2 7 2004.64 40 14.43 3304 1907 2.10 / 802.48 12 56
3 13 1912.20 20 14.41 3187 918 3.02 / 803.40 5 62
4 13 1264.00 20 14.46 2266 655 3.67 / 804.06 5 76
5 13 826.44 20 14.53 1637 476 4.15 / 804.53 5 85
6 13 77.32 20 14.80 446 132 4.28 / 804.66 6 77
7 13 22.04 20 14.82 339 100 4.38 / 804.76 6 70
8 8 0.00 246 14.77 299 1086 5.47 / 805.85 6 146
Average= 15.80
(KJ/cycle)

Cycle 150 GMT 31/12/2023 11:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 30 14.79 437 194 0.19 / 795.09 6 11
2 7 2003.08 40 14.44 3327 1922 2.12 / 797.01 11 55
3 13 1907.88 20 14.41 3182 917 3.03 / 797.93 5 62
4 13 1273.96 20 14.46 2289 662 3.69 / 798.59 5 75
5 13 745.72 20 14.56 1510 440 4.13 / 799.03 5 84
6 13 91.72 20 14.78 484 143 4.28 / 799.17 6 81
7 13 25.80 20 14.81 351 104 4.38 / 799.27 6 73
8 8 0.00 246 14.76 305 1107 5.49 / 800.38 6 134
Average= 16.01
(KJ/cycle)

Cycle 149 GMT 21/12/2023 13:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 30 14.80 427 190 0.19 / 789.55 6 11
2 7 2004.24 41 14.43 3322 1965 2.15 / 791.51 11 57
3 13 1908.00 20 14.41 3176 915 3.07 / 792.43 5 61
4 13 1362.36 20 14.44 2404 694 3.76 / 793.12 5 75
5 13 706.92 20 14.57 1444 421 4.19 / 793.55 5 83
6 13 75.24 20 14.80 453 134 4.32 / 793.68 6 79
7 13 19.76 20 14.82 341 101 4.42 / 793.78 6 74
8 8 -0.08 248 14.76 304 1113 5.53 / 794.89 6 143
Average= 16.22
(KJ/cycle)

Cycle 148 GMT 11/12/2023 16:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 30 14.79 454 201 0.20 / 784.18 6 10
2 7 2004.68 40 14.44 3304 1908 2.11 / 786.09 10 56
3 13 1906.68 20 14.41 3168 913 3.02 / 787.00 5 63
4 13 1281.08 20 14.45 2297 664 3.69 / 787.66 5 75
5 13 629.92 20 14.60 1317 385 4.07 / 788.05 5 86
6 13 86.00 20 14.80 464 137 4.21 / 788.19 6 82
7 13 22.48 20 14.82 338 100 4.31 / 788.29 6 75
8 8 0.00 244 14.77 298 1074 5.38 / 789.36 6 129
Average= 16.44
(KJ/cycle)

Cycle 147 GMT 1/12/2023 18:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 30 14.80 432 192 0.19 / 778.73 6 12
2 7 2005.36 40 14.43 3312 1912 2.10 / 780.64 12 55
3 13 1909.24 20 14.41 3182 917 3.02 / 781.56 5 63
4 13 1351.36 20 14.44 2376 686 3.71 / 782.25 5 74
5 13 692.56 20 14.58 1424 415 4.12 / 782.66 5 83
6 13 66.52 20 14.80 423 125 4.25 / 782.79 6 75
7 13 36.32 20 14.81 365 108 4.36 / 782.89 6 72
8 8 0.00 246 14.77 298 1083 5.44 / 783.98 6 137
Average= 16.68
(KJ/cycle)

Cycle 146 GMT 21/11/2023 21:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 30 14.80 429 190 0.19 / 773.31 6 10
2 7 2004.72 40 14.44 3308 1911 2.10 / 775.22 10 57
3 13 1913.08 20 14.40 3204 923 3.02 / 776.14 5 62
4 13 1373.56 20 14.43 2433 702 3.73 / 776.85 5 74
5 13 614.04 20 14.60 1307 382 4.11 / 777.23 5 85
6 13 79.32 20 14.80 452 134 4.24 / 777.36 6 75
7 13 20.88 20 14.82 337 100 4.34 / 777.46 6 68
8 8 -0.08 244 14.77 299 1078 5.42 / 778.54 6 131
Average= 16.92
(KJ/cycle)

Cycle 145 GMT 11/11/2023 23:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 30 14.79 435 193 0.19 / 767.97 6 11
2 7 2009.56 40 14.44 3313 1914 2.11 / 769.88 11 58
3 13 1817.36 20 14.43 3046 879 2.99 / 770.76 5 66
4 13 1172.92 20 14.48 2130 617 3.60 / 771.37 5 78
5 13 747.88 20 14.56 1512 440 4.04 / 771.81 5 84
6 13 85.64 20 14.79 465 138 4.18 / 771.95 6 78
7 13 22.60 20 14.81 340 101 4.28 / 772.05 6 70
8 8 -0.04 244 14.77 296 1067 5.35 / 773.12 6 132
Average= 17.18
(KJ/cycle)

Cycle 144 GMT 2/11/2023 1:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 30 14.80 456 202 0.20 / 762.60 6 11
2 7 2008.84 40 14.45 3323 1921 2.12 / 764.52 11 56
3 13 1814.84 20 14.43 3062 884 3.01 / 765.40 5 64
4 13 1288.08 20 14.46 2297 664 3.67 / 766.07 5 75
5 13 555.96 20 14.63 1223 358 4.03 / 766.42 5 85
6 13 110.04 20 14.78 516 153 4.18 / 766.58 6 83
7 13 26.04 20 14.81 350 104 4.29 / 766.68 6 74
8 8 0.00 244 14.76 303 1091 5.38 / 767.77 6 133
Average= 17.45
(KJ/cycle)

Cycle 143 GMT 23/10/2023 4:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 30 14.80 430 191 0.19 / 757.27 6 11
2 7 2005.32 40 14.44 3307 1910 2.10 / 759.18 11 55
3 13 1909.80 20 14.42 3177 916 3.02 / 760.09 5 63
4 13 1175.60 20 14.49 2127 616 3.63 / 760.71 5 78
5 13 643.68 20 14.60 1344 392 4.03 / 761.10 5 84
6 13 92.52 20 14.79 480 142 4.17 / 761.24 6 80
7 8 0.04 261 14.77 299 1153 5.32 / 762.40 6 136
Average= 17.73
(KJ/cycle)

Cycle 142 GMT 13/10/2023 6:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 30 14.80 426 189 0.19 / 751.85 6 9
2 7 2005.60 40 14.44 3319 1917 2.11 / 753.76 7 56
3 13 1910.60 20 14.43 3179 917 3.02 / 754.68 5 63
4 13 1258.64 20 14.47 2246 650 3.67 / 755.33 5 75
5 13 729.80 20 14.57 1483 432 4.11 / 755.76 5 85
6 13 83.28 20 14.80 459 136 4.24 / 755.90 6 78
7 8 0.08 267 14.77 298 1175 5.42 / 757.07 6 132
Average= 18.03
(KJ/cycle)

Cycle 141 GMT 3/10/2023 8:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 30 14.81 426 189 0.19 / 746.44 6 10
2 7 2012.04 40 14.45 3306 1911 2.10 / 748.35 10 58
3 13 1816.84 20 14.44 3035 877 2.98 / 749.22 5 66
4 13 1496.68 20 14.42 2575 743 3.72 / 749.97 5 75
5 13 629.04 20 14.60 1325 387 4.11 / 750.35 5 85
6 13 95.84 20 14.79 476 141 4.25 / 750.49 6 81
7 13 26.60 20 14.82 334 99 4.35 / 750.59 6 73
8 8 -0.08 246 14.77 293 1065 5.41 / 751.66 6 135
Average= 18.33
(KJ/cycle)

Cycle 140 GMT 23/ 9/2023 11:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 30 14.80 431 191 0.19 / 741.02 6 10
2 7 2005.12 40 14.46 3292 1904 2.10 / 742.93 10 57
3 13 1909.68 20 14.43 3169 915 3.01 / 743.84 5 64
4 13 1371.92 20 14.45 2408 696 3.71 / 744.54 5 76
5 13 730.88 20 14.58 1460 426 4.13 / 744.96 5 85
6 13 92.36 20 14.80 465 138 4.27 / 745.10 6 77
7 13 25.76 20 14.82 335 99 4.37 / 745.20 6 71
8 8 0.00 242 14.78 293 1048 5.42 / 746.25 6 132
Average= 18.66
(KJ/cycle)

Cycle 139 GMT 13/ 9/2023 13:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 30 14.81 431 191 0.19 / 735.58 6 9
2 7 2004.40 40 14.45 3317 1917 2.11 / 737.50 9 57
3 13 1911.16 20 14.43 3191 921 3.03 / 738.42 5 62
4 13 1269.36 20 14.47 2265 655 3.69 / 739.07 5 75
5 13 737.76 20 14.57 1489 434 4.12 / 739.51 5 82
6 13 89.12 20 14.79 467 138 4.26 / 739.64 6 76
7 13 27.16 20 14.82 343 102 4.36 / 739.75 6 72
8 8 0.04 249 14.77 295 1085 5.44 / 740.83 6 143
Average= 19.00
(KJ/cycle)

Cycle 138 GMT 3/ 9/2023 16:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 29 14.79 436 187 0.19 / 730.22 6 9
2 7 2003.04 40 14.45 3309 1913 2.10 / 732.13 9 57
3 13 1811.20 20 14.44 3020 872 2.97 / 733.00 5 64
4 13 1286.76 20 14.47 2303 666 3.64 / 733.67 5 76
5 13 650.88 20 14.60 1368 399 4.04 / 734.07 5 85
6 13 99.40 20 14.79 491 145 4.18 / 734.21 6 77
7 13 27.00 20 14.82 348 103 4.29 / 734.31 6 70
8 8 0.12 246 14.78 295 1073 5.36 / 735.39 6 138
Average= 19.35
(KJ/cycle)

Cycle 137 GMT 24/ 8/2023 18:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 29 14.82 451 194 0.19 / 724.77 6 10
2 7 2004.08 41 14.45 3313 1963 2.16 / 726.73 7 56
3 13 1908.76 20 14.42 3163 912 3.07 / 727.64 5 62
4 13 1272.28 20 14.46 2281 660 3.73 / 728.30 5 76
5 13 633.72 20 14.60 1348 394 4.12 / 728.69 5 84
6 13 89.56 20 14.79 478 141 4.26 / 728.84 6 77
7 13 26.88 20 14.81 356 105 4.37 / 728.94 6 69
8 8 0.04 244 14.76 302 1088 5.46 / 730.03 6 133
Average= 19.73
(KJ/cycle)

Cycle 136 GMT 14/ 8/2023 20:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 29 14.81 437 188 0.19 / 719.31 6 12
2 7 2004.36 40 14.46 3301 1909 2.10 / 721.22 12 57
3 13 1910.56 20 14.42 3198 922 3.02 / 722.15 5 61
4 13 1371.48 20 14.46 2420 700 3.72 / 722.85 5 75
5 13 710.08 20 14.59 1446 422 4.14 / 723.27 5 85
6 13 84.84 20 14.81 455 135 4.28 / 723.40 6 75
7 13 24.04 20 14.83 334 99 4.37 / 723.50 6 66
8 8 0.00 246 14.79 294 1070 5.44 / 724.57 6 130
Average= 20.13
(KJ/cycle)

Cycle 135 GMT 4/ 8/2023 23:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 29 14.79 442 190 0.19 / 713.89 6 11
2 7 2008.52 40 14.45 3334 1927 2.12 / 715.82 11 57
3 13 1911.80 20 14.43 3178 917 3.03 / 716.74 5 60
4 13 1256.84 20 14.49 2244 650 3.68 / 717.39 5 77
5 13 725.68 20 14.58 1471 429 4.11 / 717.81 5 86
6 13 87.36 20 14.81 468 139 4.25 / 717.95 6 73
7 13 24.56 20 14.83 340 101 4.35 / 718.05 6 69
8 8 0.04 246 14.79 295 1073 5.43 / 719.13 6 136
Average= 20.55
(KJ/cycle)

Cycle 134 GMT 26/ 7/2023 1:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 29 14.83 438 188 0.19 / 708.47 6 10
2 7 2006.36 41 14.45 3314 1963 2.15 / 710.43 10 58
3 13 1812.12 20 14.45 3027 875 3.03 / 711.31 5 64
4 13 1268.12 20 14.47 2268 656 3.68 / 711.96 5 76
5 13 725.08 20 14.57 1481 432 4.11 / 712.39 5 87
6 13 84.60 20 14.80 459 136 4.25 / 712.53 6 76
7 13 24.64 20 14.81 343 102 4.35 / 712.63 6 71
8 8 0.04 244 14.77 297 1070 5.42 / 713.70 6 142
Average= 20.99
(KJ/cycle)

Cycle 133 GMT 16/ 7/2023 4: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 29 14.81 444 191 0.19 / 703.05 6 10
2 7 2007.68 40 14.46 3310 1915 2.11 / 704.96 7 56
3 13 1817.24 20 14.44 3073 887 2.99 / 705.85 5 64
4 13 1297.36 20 14.46 2324 672 3.66 / 706.52 5 75
5 13 747.88 20 14.58 1508 440 4.10 / 706.96 5 85
6 13 91.12 20 14.81 478 142 4.25 / 707.10 6 76
7 13 25.08 20 14.83 351 104 4.35 / 707.21 6 72
8 8 0.08 242 14.79 300 1074 5.42 / 708.28 6 135
Average= 21.46
(KJ/cycle)

Cycle 132 GMT 6/ 7/2023 6:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 29 14.80 445 191 0.19 / 697.59 6 11
2 7 2003.64 40 14.45 3314 1915 2.11 / 699.51 11 58
3 13 1907.44 20 14.43 3164 913 3.02 / 700.42 5 62
4 13 1265.92 20 14.48 2273 658 3.68 / 701.08 5 76
5 13 827.44 20 14.56 1618 471 4.15 / 701.55 5 85
6 13 80.16 20 14.81 450 133 4.28 / 701.69 6 75
7 13 23.28 20 14.83 343 102 4.38 / 701.79 6 69
8 8 0.08 244 14.78 296 1067 5.45 / 702.86 6 132
Average= 21.96
(KJ/cycle)

Cycle 131 GMT 26/ 6/2023 8:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 28 14.80 447 185 0.19 / 692.13 6 10
2 7 2007.44 41 14.45 3318 1966 2.15 / 694.09 17 57
3 13 1811.04 20 14.44 3058 883 3.03 / 694.97 5 64
4 13 1277.00 20 14.47 2289 662 3.70 / 695.64 5 76
5 13 732.20 20 14.58 1498 437 4.13 / 696.07 5 86
6 13 83.36 20 14.80 465 138 4.27 / 696.21 6 77
7 13 24.64 20 14.82 349 103 4.37 / 696.31 6 70
8 13 12.28 20 14.82 327 97 4.47 / 696.41 6 67
9 8 0.00 223 14.78 301 992 5.46 / 697.40 6 131
Average= 22.50
(KJ/cycle)

Cycle 130 GMT 16/ 6/2023 11:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 30 14.81 437 194 0.19 / 686.72 6 12
2 3 944.08 -1 15.32 2 0 0.00 / 686.72 6 12
3 7 2009.80 40 14.46 3327 1924 2.12 / 688.64 12 58
4 13 1815.52 20 14.45 3049 881 3.00 / 689.52 5 65
5 13 1285.00 20 14.47 2298 665 3.66 / 690.19 5 74
6 13 739.64 20 14.58 1491 435 4.10 / 690.62 5 83
7 13 93.56 20 14.80 470 139 4.24 / 690.76 6 75
8 13 25.44 20 14.82 346 103 4.34 / 690.87 6 66
9 13 21.36 20 14.82 336 100 4.44 / 690.97 6 68
10 8 0.20 225 14.78 293 974 5.42 / 691.94 6 135
Average= 23.06
(KJ/cycle)

Cycle 129 GMT 6/ 6/2023 13:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 30 14.81 451 200 0.20 / 681.38 6 12
2 7 2005.08 40 14.47 3300 1910 2.11 / 683.29 12 58
3 13 1710.68 20 14.46 2923 845 2.96 / 684.13 5 68
4 13 1299.32 20 14.47 2327 673 3.63 / 684.81 5 74
5 13 647.40 20 14.61 1353 395 4.02 / 685.20 5 86
6 13 93.72 20 14.80 475 141 4.17 / 685.34 6 81
7 13 23.12 20 14.82 338 100 4.27 / 685.44 6 72
8 13 10.40 20 14.82 315 93 4.36 / 685.54 6 70
9 8 0.12 227 14.78 295 990 5.35 / 686.53 6 144
Average= 23.67
(KJ/cycle)

Cycle 128 GMT 27/ 5/2023 15:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 30 14.81 446 198 0.20 / 675.89 6 12
2 7 2003.88 40 14.47 3313 1918 2.12 / 677.81 12 58
3 13 1906.12 20 14.44 3180 918 3.03 / 678.72 5 63
4 13 1271.68 20 14.49 2271 658 3.69 / 679.38 5 75
5 13 836.84 20 14.56 1640 478 4.17 / 679.86 5 82
6 13 84.00 20 14.82 460 136 4.31 / 680.00 6 77
7 13 23.48 20 14.84 342 102 4.41 / 680.10 6 70
8 8 0.08 244 14.79 299 1079 5.49 / 681.18 6 130
Average= 24.33
(KJ/cycle)

Cycle 127 GMT 17/ 5/2023 18:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 30 14.80 443 197 0.20 / 670.45 6 13
2 7 2003.44 40 14.46 3311 1915 2.11 / 672.36 13 57
3 13 1906.72 20 14.43 3178 917 3.03 / 673.28 5 61
4 13 1273.40 20 14.49 2278 660 3.69 / 673.94 5 75
5 13 719.00 20 14.59 1470 429 4.12 / 674.37 5 87
6 13 78.64 20 14.82 448 133 4.25 / 674.50 6 78
7 13 20.28 20 14.83 342 101 4.35 / 674.61 6 70
8 8 0.04 242 14.79 303 1084 5.44 / 675.69 6 129
Average= 25.03
(KJ/cycle)

Cycle 126 GMT 7/ 5/2023 20:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 30 14.83 457 203 0.20 / 665.11 6 13
2 7 2003.88 41 14.47 3306 1961 2.16 / 667.07 13 56
3 13 1808.36 20 14.45 3035 877 3.04 / 667.94 5 64
4 13 1171.84 20 14.51 2129 618 3.66 / 668.56 5 78
5 13 632.96 20 14.62 1341 392 4.05 / 668.95 5 87
6 13 85.20 20 14.82 458 136 4.19 / 669.09 6 80
7 8 0.00 263 14.79 299 1163 5.35 / 670.25 6 140
Average= 25.78
(KJ/cycle)

Cycle 125 GMT 27/ 4/2023 23:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 30 14.78 444 197 0.20 / 659.67 6 14
2 7 2008.80 40 14.46 3316 1918 2.11 / 661.59 14 57
3 13 1911.96 20 14.44 3201 924 3.04 / 662.52 5 60
4 13 1251.80 20 14.48 2258 654 3.69 / 663.17 5 78
5 13 713.24 20 14.59 1466 428 4.12 / 663.60 5 86
6 13 76.64 20 14.82 450 133 4.25 / 663.73 6 78
7 8 0.08 263 14.80 301 1172 5.43 / 664.90 6 133
Average= 26.60
(KJ/cycle)

Cycle 124 GMT 18/ 4/2023 2: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 30 14.81 437 194 0.19 / 654.24 6 14
2 7 2004.80 40 14.46 3317 1919 2.11 / 656.16 14 55
3 13 1907.32 20 14.44 3194 922 3.04 / 657.08 5 60
4 13 1269.16 20 14.49 2259 655 3.69 / 657.73 5 76
5 13 729.44 20 14.57 1483 432 4.12 / 658.16 5 84
6 13 86.20 20 14.79 468 138 4.26 / 658.30 6 81
7 8 0.16 264 14.77 301 1174 5.43 / 659.48 6 130
Average= 27.48
(KJ/cycle)

Cycle 123 GMT 8/ 4/2023 4:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 30 14.81 443 197 0.20 / 648.98 6 12
2 7 2003.40 40 14.47 3308 1915 2.11 / 650.89 12 54
3 13 1807.60 20 14.46 3054 883 2.99 / 651.78 5 63
4 13 1180.40 20 14.51 2133 619 3.61 / 652.40 5 76
5 13 551.32 20 14.65 1203 352 3.97 / 652.75 5 87
6 13 68.92 20 14.82 426 126 4.09 / 652.88 6 77
7 8 0.08 264 14.79 299 1167 5.26 / 654.04 6 141
Average= 28.44
(KJ/cycle)

Cycle 122 GMT 29/ 3/2023 7: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 29 14.82 466 200 0.20 / 643.65 6 12
2 7 2006.96 40 14.47 3314 1918 2.12 / 645.57 8 59
3 13 1820.40 20 14.45 3070 887 3.01 / 646.46 5 64
4 13 1195.96 20 14.49 2164 627 3.63 / 647.09 5 77
5 13 569.92 20 14.64 1240 363 4.00 / 647.45 5 84
6 13 70.04 20 14.81 439 130 4.13 / 647.58 6 77
7 8 0.12 266 14.79 306 1204 5.33 / 648.78 6 145
Average= 29.49
(KJ/cycle)

Cycle 121 GMT 19/ 3/2023 9:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 29 14.81 447 192 0.19 / 638.21 6 13
2 7 2008.28 40 14.48 3307 1915 2.11 / 640.13 13 55
3 13 1915.56 20 14.44 3198 924 3.03 / 641.05 5 63
4 13 1292.76 20 14.48 2313 670 3.70 / 641.72 5 79
5 13 741.48 20 14.59 1497 437 4.14 / 642.16 5 82
6 13 92.24 20 14.82 472 140 4.28 / 642.30 6 80
7 8 0.04 261 14.79 299 1154 5.43 / 643.45 6 136
Average= 30.64
(KJ/cycle)

Cycle 120 GMT 9/ 3/2023 11:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 29 14.80 472 203 0.20 / 632.67 6 17
2 7 2009.84 40 14.48 3324 1925 2.13 / 634.60 17 57
3 13 1913.56 20 14.44 3206 926 3.05 / 635.52 5 64
4 13 1381.52 20 14.47 2439 706 3.76 / 636.23 5 76
5 13 726.96 20 14.60 1486 434 4.19 / 636.66 5 87
6 13 87.36 20 14.82 475 141 4.33 / 636.80 6 80
7 13 47.32 20 14.83 389 115 4.45 / 636.92 6 77
8 8 0.04 242 14.79 308 1102 5.55 / 638.02 6 129
Average= 31.90
(KJ/cycle)

Cycle 119 GMT 27/ 2/2023 14: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 29 14.81 436 187 0.19 / 627.16 6 14
2 7 2013.24 40 14.47 3313 1918 2.10 / 629.08 14 59
3 13 1914.92 20 14.43 3199 923 3.03 / 630.01 5 64
4 13 1470.68 20 14.45 2568 742 3.77 / 630.75 5 72
5 13 680.44 20 14.61 1406 411 4.18 / 631.16 5 88
6 13 67.16 20 14.83 429 127 4.31 / 631.29 6 78
7 8 -0.04 263 14.80 304 1183 5.49 / 632.47 6 136
Average= 33.29
(KJ/cycle)

Cycle 118 GMT 17/ 2/2023 16:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 29 14.83 453 195 0.19 / 621.70 6 13
2 7 2005.12 40 14.48 3311 1918 2.11 / 623.62 13 58
3 13 1912.96 20 14.45 3180 919 3.03 / 624.54 5 63
4 13 1362.20 20 14.48 2418 700 3.73 / 625.24 5 78
5 13 701.64 20 14.60 1441 421 4.15 / 625.66 5 85
6 13 76.24 20 14.82 446 132 4.28 / 625.79 6 81
7 8 -0.04 265 14.79 303 1188 5.47 / 626.98 6 131
Average= 34.83
(KJ/cycle)

Cycle 117 GMT 7/ 2/2023 19: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 29 14.83 463 199 0.20 / 616.24 6 14
2 7 2005.68 40 14.48 3298 1910 2.11 / 618.15 14 59
3 13 1913.60 20 14.44 3179 918 3.03 / 619.07 5 61
4 13 1359.20 20 14.49 2385 691 3.72 / 619.76 5 76
5 13 705.08 20 14.61 1441 421 4.14 / 620.18 5 86
6 13 74.88 20 14.83 439 130 4.27 / 620.31 6 81
7 13 19.00 20 14.85 331 98 4.37 / 620.41 6 74
8 8 -0.04 246 14.80 300 1092 5.46 / 621.51 6 139
Average= 36.56
(KJ/cycle)

Cycle 116 GMT 28/ 1/2023 21:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 29 14.81 448 192 0.19 / 610.74 6 12
2 7 2008.72 40 14.47 3311 1916 2.11 / 612.66 12 58
3 13 1818.36 20 14.47 3066 887 3.00 / 613.55 5 66
4 13 1390.40 20 14.47 2459 712 3.71 / 614.26 5 77
5 13 734.24 20 14.60 1492 436 4.14 / 614.70 5 87
6 13 78.84 20 14.83 462 137 4.28 / 614.83 6 80
7 8 0.04 265 14.81 309 1213 5.49 / 616.04 6 144
Average= 38.50
(KJ/cycle)

Cycle 115 GMT 19/ 1/2023 0: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 29 14.82 447 192 0.19 / 605.34 6 15
2 7 2005.60 40 14.48 3313 1919 2.11 / 607.26 15 55
3 13 1913.96 20 14.46 3178 919 3.03 / 608.18 5 61
4 13 1268.56 20 14.50 2281 661 3.69 / 608.84 5 78
5 13 625.12 20 14.64 1329 389 4.08 / 609.23 5 88
6 13 80.16 20 14.83 460 136 4.22 / 609.36 6 80
7 8 0.04 263 14.81 305 1188 5.41 / 610.55 6 142
Average= 40.70
(KJ/cycle)

Cycle 114 GMT 9/ 1/2023 2:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 29 14.81 447 192 0.19 / 599.73 6 12
2 7 2012.84 40 14.48 3342 1936 2.13 / 601.66 12 55
3 13 1914.20 20 14.44 3195 923 3.05 / 602.59 5 65
4 13 1370.56 20 14.48 2435 705 3.76 / 603.29 5 75
5 13 810.80 20 14.58 1620 472 4.23 / 603.76 5 86
6 13 64.44 20 14.85 434 129 4.36 / 603.89 6 80
7 13 35.28 20 14.85 381 113 4.47 / 604.01 6 75
8 8 -0.04 246 14.80 313 1140 5.61 / 605.15 6 144
Average= 43.22
(KJ/cycle)

Cycle 113 GMT 30/12/2022 5:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 29 14.84 456 196 0.20 / 594.32 6 12
2 7 2009.92 40 14.48 3304 1914 2.11 / 596.23 12 59
3 13 1808.48 20 14.46 3061 885 3.00 / 597.12 5 67
4 13 1277.76 20 14.50 2284 662 3.66 / 597.78 5 78
5 13 739.60 20 14.60 1498 437 4.09 / 598.22 5 87
6 13 81.76 20 14.83 458 136 4.23 / 598.35 6 81
7 8 0.04 263 14.80 304 1183 5.41 / 599.54 6 139
Average= 46.12
(KJ/cycle)

Cycle 112 GMT 20/12/2022 7:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 29 14.82 455 196 0.20 / 588.90 6 15
2 7 2013.40 40 14.48 3333 1930 2.13 / 590.83 15 57
3 13 1916.20 20 14.45 3199 925 3.05 / 591.75 5 64
4 13 1269.56 20 14.51 2283 663 3.71 / 592.41 5 78
5 13 617.60 20 14.64 1322 387 4.10 / 592.80 5 88
6 13 80.12 20 14.84 459 136 4.24 / 592.94 6 84
7 13 23.04 20 14.86 346 103 4.34 / 593.04 6 74
8 8 0.04 240 14.81 305 1084 5.42 / 594.12 6 132
Average= 49.51
(KJ/cycle)

Cycle 111 GMT 10/12/2022 10:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 30 14.82 456 203 0.20 / 583.36 6 14
2 7 2005.04 40 14.48 3323 1925 2.13 / 585.28 14 60
3 13 1911.36 20 14.46 3200 925 3.05 / 586.21 5 65
4 13 1157.96 20 14.53 2129 619 3.67 / 586.83 5 80
5 13 836.08 20 14.57 1662 484 4.16 / 587.31 5 85
6 13 70.88 20 14.83 460 136 4.29 / 587.45 6 80
7 13 18.96 20 14.85 358 106 4.40 / 587.55 6 75
8 8 0.04 244 14.80 317 1145 5.54 / 588.70 6 141
Average= 53.52
(KJ/cycle)

Cycle 110 GMT 30/11/2022 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 29 14.84 455 196 0.20 / 577.87 6 12
2 3 1041.20 1 14.95 1959 29 0.23 / 577.90 5 43
3 7 2010.28 40 14.48 3326 1926 2.15 / 579.83 43 58
4 13 1913.56 20 14.46 3209 928 3.08 / 580.75 5 64
5 13 1268.92 20 14.51 2287 664 3.74 / 581.42 5 77
6 13 540.00 20 14.67 1206 354 4.10 / 581.77 5 88
7 13 53.72 20 14.85 423 126 4.22 / 581.90 6 83
8 13 15.56 20 14.86 350 104 4.33 / 582.00 6 78
9 8 -0.12 244 14.80 320 1156 5.48 / 583.16 6 134
Average= 58.32
(KJ/cycle)

Cycle 109 GMT 20/11/2022 14:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 30 14.83 444 198 0.20 / 572.46 6 10
2 3 967.28 -1 15.33 2 0 0.00 / 572.46 6 10
3 7 2004.56 40 14.48 3311 1918 2.12 / 574.38 10 56
4 13 1795.36 20 14.48 3024 876 2.99 / 575.25 5 64
5 13 1369.60 20 14.49 2417 700 3.69 / 575.95 5 75
6 13 601.56 20 14.66 1299 381 4.07 / 576.33 5 85
7 13 70.64 20 14.85 447 133 4.21 / 576.47 6 86
8 8 0.04 261 14.82 312 1207 5.41 / 577.67 6 134
Average= 64.19
(KJ/cycle)

Cycle 108 GMT 10/11/2022 17:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 30 14.85 441 196 0.20 / 567.14 6 13
2 7 1948.32 40 14.49 3227 1870 2.07 / 569.01 13 64
3 13 1752.28 20 14.49 2970 861 2.93 / 569.87 5 72
4 13 1229.72 20 14.52 2211 642 3.57 / 570.51 5 81
5 13 675.52 20 14.62 1416 414 3.98 / 570.92 5 89
6 13 62.12 20 14.84 435 129 4.11 / 571.05 6 81
7 8 0.08 261 14.80 313 1209 5.32 / 572.26 6 135
Average= 71.53
(KJ/cycle)

Cycle 107 GMT 31/10/2022 16:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 30 14.83 453 202 0.20 / 561.66 6 10
2 7 2010.36 40 14.49 3319 1924 2.13 / 563.59 10 57
3 13 1920.84 20 14.46 3206 927 3.05 / 564.51 5 65
4 13 1366.36 20 14.49 2401 696 3.75 / 565.21 5 76
5 13 612.16 20 14.66 1310 384 4.13 / 565.59 5 88
6 13 74.96 20 14.85 461 137 4.27 / 565.73 6 87
7 13 20.16 20 14.87 352 105 4.37 / 565.84 6 80
8 8 -0.08 242 14.82 308 1105 5.48 / 566.94 6 135
Average= 80.99
(KJ/cycle)

Cycle 106 GMT 21/10/2022 18:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 30 14.84 437 195 0.19 / 556.14 6 15
2 3 1019.32 1 14.99 1924 29 0.22 / 556.17 5 23
3 7 2009.64 40 14.49 3321 1925 2.15 / 558.09 23 57
4 13 1816.60 20 14.47 3058 885 3.03 / 558.98 5 67
5 13 1278.36 20 14.51 2299 667 3.70 / 559.65 5 75
6 13 726.00 20 14.62 1483 434 4.13 / 560.08 5 85
7 13 73.60 20 14.85 462 137 4.27 / 560.22 6 83
8 13 21.08 20 14.86 360 107 4.38 / 560.32 6 78
9 8 -0.08 244 14.81 315 1138 5.52 / 561.46 6 140
Average= 93.58
(KJ/cycle)

Cycle 105 GMT 11/10/2022 21:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 30 14.88 451 201 0.20 / 550.55 6 12
2 7 2013.04 41 14.49 3314 1969 2.17 / 552.52 12 59
3 13 1922.96 20 14.46 3186 921 3.09 / 553.44 5 64
4 13 1281.68 20 14.51 2310 670 3.76 / 554.11 5 78
5 13 850.76 20 14.58 1671 487 4.25 / 554.60 5 84
6 13 78.40 20 14.84 463 137 4.39 / 554.73 6 85
7 13 22.08 20 14.86 354 105 4.49 / 554.84 6 81
8 8 -0.08 240 14.81 311 1105 5.60 / 555.95 6 132
Average= 111.19
(KJ/cycle)

Cycle 104 GMT 1/10/2022 23:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 30 14.84 457 203 0.20 / 545.03 6 12
2 7 2010.44 41 14.47 3311 1964 2.17 / 546.99 12 60
3 13 1815.76 20 14.45 3058 884 3.05 / 547.87 5 67
4 13 1384.44 20 14.48 2445 708 3.76 / 548.58 5 76
5 13 713.16 20 14.64 1462 428 4.19 / 549.01 5 88
6 13 80.64 20 14.88 461 137 4.32 / 549.15 6 84
7 13 44.36 20 14.88 387 115 4.44 / 549.26 6 81
8 8 -0.04 242 14.85 302 1085 5.53 / 550.35 6 139
Average= 137.59
(KJ/cycle)

Cycle 103 GMT 22/ 9/2022 2:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 30 14.88 451 201 0.20 / 540.63 6 12
2 7 1280.64 40 14.80 2262 1339 1.54 / 541.97 12 72
3 13 1214.96 20 14.78 2168 641 2.18 / 542.61 5 75
4 13 1024.20 20 14.75 1922 567 2.75 / 543.18 5 80
5 13 471.08 20 14.81 1108 328 3.08 / 543.51 5 89
6 13 53.16 20 14.92 420 125 3.20 / 543.63 6 84
7 13 14.68 20 14.92 341 102 3.30 / 543.73 6 78
8 8 -0.12 235 14.86 312 1090 4.39 / 544.82 6 141
Average= 181.61
(KJ/cycle)

Cycle 102 GMT 12/ 9/2022 3:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 30 14.84 447 199 0.20 / 535.14 6 11
2 7 2005.24 40 14.49 3290 1907 2.11 / 537.04 11 59
3 13 1911.84 20 14.45 3171 916 3.02 / 537.96 5 65
4 13 1262.88 20 14.51 2273 660 3.68 / 538.62 5 77
5 13 728.80 20 14.63 1480 433 4.11 / 539.05 5 86
6 13 151.12 20 14.84 586 174 4.29 / 539.23 6 89
7 13 37.64 20 14.88 371 110 4.40 / 539.34 6 78
8 8 0.00 244 14.84 302 1094 5.49 / 540.43 6 138
Average= 270.21
(KJ/cycle)

Cycle 101 GMT 2/ 9/2022 6: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 30 14.88 453 202 0.20 / 530.83 6 13
2 7 1277.80 40 14.80 2264 1340 1.54 / 532.17 6 72
3 13 1214.12 20 14.78 2194 649 2.19 / 532.82 5 75
4 13 1022.00 20 14.76 1905 562 2.75 / 533.39 5 81
5 13 263.44 20 14.87 790 235 2.99 / 533.62 5 88
6 13 81.68 20 14.91 469 140 3.13 / 533.76 6 84
7 8 0.04 255 14.88 310 1176 4.30 / 534.94 6 133
Average= 534.94
(KJ/cycle)

Cycle 99 GMT 13/ 8/2022 9:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 29 14.84 457 197 0.20 / 526.30 6 12
2 3 1027.40 1 14.98 1927 29 0.23 / 526.33 5 35
3 7 1348.24 40 14.76 2377 1403 1.63 / 527.74 35 69
4 13 1275.16 20 14.73 2291 675 2.30 / 528.41 5 75
5 13 1084.12 20 14.72 1997 588 2.89 / 529.00 5 79
6 13 408.64 20 14.82 1014 301 3.19 / 529.30 5 90
7 13 93.12 20 14.90 498 148 3.34 / 529.45 6 88
8 13 10.88 20 14.92 330 98 3.44 / 529.55 6 77
9 8 0.00 235 14.86 311 1086 4.53 / 530.63 6 144
Average= 106.13
(KJ/cycle)

Cycle 98 GMT 3/ 8/2022 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 29 14.85 439 189 0.19 / 521.71 6 13
2 7 1441.48 40 14.74 2495 1471 1.66 / 523.18 13 68
3 13 1369.52 20 14.71 2404 707 2.37 / 523.89 5 72
4 13 1058.04 20 14.71 1963 578 2.94 / 524.47 5 79
5 13 512.28 20 14.78 1156 342 3.29 / 524.81 5 88
6 13 82.88 20 14.89 466 139 3.43 / 524.95 6 86
7 8 0.20 257 14.86 303 1157 4.58 / 526.11 6 134
Average= 131.53
(KJ/cycle)

Cycle 97 GMT 24/ 7/2022 10:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 29 14.86 454 196 0.20 / 516.19 6 12
2 7 2010.20 40 14.50 3331 1932 2.13 / 518.12 12 57
3 13 1912.88 20 14.47 3207 928 3.06 / 519.05 5 66
4 13 1152.00 20 14.56 2111 615 3.67 / 519.66 5 82
5 13 938.36 20 14.56 1785 520 4.19 / 520.18 5 84
6 13 58.96 20 14.87 423 126 4.32 / 520.31 6 83
7 13 32.92 20 14.87 375 112 4.43 / 520.42 6 80
8 8 0.00 240 14.83 311 1107 5.53 / 521.52 6 134
Average= 173.84
(KJ/cycle)

Cycle 96 GMT 14/ 7/2022 13:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 29 14.87 447 193 0.19 / 510.79 6 11
2 7 2009.68 40 14.49 3340 1936 2.13 / 512.72 11 57
3 13 1915.04 20 14.48 3177 920 3.05 / 513.64 5 64
4 13 1266.36 20 14.53 2290 665 3.71 / 514.31 5 77
5 13 523.08 20 14.70 1182 348 4.06 / 514.66 5 90
6 13 53.96 20 14.88 416 124 4.19 / 514.78 6 83
7 13 30.00 20 14.87 372 111 4.30 / 514.89 6 81
8 8 0.04 240 14.83 309 1100 5.40 / 515.99 6 130
Average= 257.99
(KJ/cycle)

Cycle 95 GMT 4/ 7/2022 15:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 28 14.85 449 187 0.19 / 505.30 6 13
2 3 1030.40 1 14.97 1943 29 0.22 / 505.33 5 41
3 7 2010.08 40 14.49 3327 1928 2.14 / 507.25 41 60
4 13 1921.52 20 14.47 3204 927 3.07 / 508.18 5 63
5 13 1268.40 20 14.52 2293 666 3.74 / 508.85 5 79
6 13 617.84 20 14.67 1323 388 4.13 / 509.24 5 88
7 13 75.20 20 14.87 463 138 4.26 / 509.37 6 87
8 13 17.92 20 14.88 352 105 4.37 / 509.48 6 81
9 8 0.00 238 14.84 316 1116 5.48 / 510.59 6 132
Average= 510.59
(KJ/cycle)

Cycle 93 GMT 14/ 6/2022 18:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 29 14.83 459 197 0.20 / 499.86 6 12
2 7 1993.20 41 14.47 3310 1964 2.16 / 501.83 12 62
3 13 1801.68 20 14.48 3030 877 3.04 / 502.70 5 68
4 13 1167.12 20 14.53 2130 619 3.66 / 503.32 5 81
5 13 724.60 20 14.61 1478 432 4.09 / 503.75 5 89
6 13 72.92 20 14.85 452 134 4.22 / 503.89 6 83
7 13 24.36 20 14.86 360 107 4.33 / 503.99 6 77
8 8 0.04 242 14.82 311 1115 5.45 / 505.11 6 129
Average= 5.37
(KJ/cycle)

Cycle 92 GMT 4/ 6/2022 17:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 29 14.86 464 200 0.20 / 495.21 6 11
2 7 1479.08 40 14.72 2561 1508 1.71 / 496.71 11 69
3 13 1401.04 20 14.70 2448 720 2.43 / 497.43 5 73
4 13 1093.52 20 14.69 2006 589 3.02 / 498.02 5 80
5 13 431.40 20 14.79 1038 307 3.32 / 498.33 5 87
6 13 93.96 20 14.88 478 142 3.47 / 498.47 6 80
7 13 27.72 20 14.90 357 106 3.57 / 498.58 6 71
8 8 -0.04 238 14.84 307 1084 4.66 / 499.66 6 133
Average= 5.37
(KJ/cycle)

Cycle 91 GMT 25/ 5/2022 17:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 29 14.85 455 196 0.20 / 490.05 6 12
2 7 1689.60 40 14.62 2874 1681 1.88 / 491.73 12 67
3 13 1609.64 20 14.59 2769 808 2.68 / 492.54 5 70
4 13 1293.68 20 14.59 2316 676 3.36 / 493.22 5 79
5 13 726.72 20 14.67 1496 439 3.80 / 493.65 5 86
6 13 86.08 20 14.88 472 140 3.94 / 493.79 6 75
7 13 47.24 20 14.88 391 116 4.06 / 493.91 6 71
8 8 0.00 242 14.85 305 1096 5.15 / 495.01 6 130
Average= 5.38
(KJ/cycle)

Cycle 90 GMT 15/ 5/2022 17:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 29 14.83 476 205 0.20 / 485.45 6 12
2 7 1535.56 40 14.68 2644 1553 1.76 / 487.00 12 69
3 13 1455.28 20 14.65 2552 748 2.51 / 487.75 5 72
4 13 1034.60 20 14.68 1915 562 3.07 / 488.31 5 82
5 13 296.00 20 14.83 826 245 3.31 / 488.56 5 85
6 13 47.08 20 14.90 397 118 3.43 / 488.67 6 76
7 8 -0.04 257 14.86 309 1180 4.61 / 489.85 6 142
Average= 5.38
(KJ/cycle)

Cycle 89 GMT 5/ 5/2022 18:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 29 14.88 471 203 0.20 / 480.66 6 12
2 7 1514.88 40 14.69 2625 1542 1.75 / 482.21 12 68
3 13 1438.92 20 14.67 2531 743 2.49 / 482.95 5 74
4 13 1032.84 20 14.69 1928 566 3.05 / 483.52 5 81
5 13 599.88 20 14.74 1299 383 3.44 / 483.90 5 88
6 13 67.48 20 14.88 434 129 3.57 / 484.03 6 72
7 13 15.76 20 14.89 344 102 3.67 / 484.13 6 67
8 8 0.04 240 14.83 313 1114 4.78 / 485.24 6 132
Average= 5.39
(KJ/cycle)

Cycle 88 GMT 25/ 4/2022 18:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 28 14.85 461 192 0.19 / 475.19 6 13
2 3 1024.56 1 15.00 1940 29 0.22 / 475.22 5 29
3 7 1911.76 40 14.52 3198 1857 2.08 / 477.08 29 61
4 13 1821.60 20 14.49 3092 896 2.97 / 477.98 5 68
5 13 1383.00 20 14.51 2445 710 3.68 / 478.68 5 79
6 13 615.72 20 14.68 1332 391 4.07 / 479.08 5 87
7 13 158.16 20 14.85 597 177 4.25 / 479.25 6 76
8 13 16.32 20 14.91 330 98 4.35 / 479.35 6 61
9 8 0.04 244 14.86 306 1110 5.46 / 480.46 6 136
Average= 5.40
(KJ/cycle)

Cycle 87 GMT 15/ 4/2022 18:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 28 14.89 447 186 0.19 / 470.85 6 12
2 7 1280.88 40 14.81 2264 1341 1.53 / 472.19 12 72
3 13 1215.92 20 14.79 2183 646 2.17 / 472.84 5 76
4 13 1020.24 20 14.77 1912 565 2.74 / 473.40 5 80
5 13 469.72 20 14.85 1090 324 3.06 / 473.73 5 84
6 13 59.84 20 14.94 409 122 3.18 / 473.85 6 71
7 13 18.24 20 14.94 335 100 3.28 / 473.95 6 67
8 8 0.12 233 14.89 303 1051 4.34 / 475.00 6 138
Average= 5.40
(KJ/cycle)

Cycle 86 GMT 5/ 4/2022 19:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 28 14.88 454 189 0.19 / 465.43 6 13
2 7 2005.28 40 14.49 3330 1930 2.12 / 467.36 13 58
3 13 1914.52 20 14.46 3202 926 3.05 / 468.29 5 63
4 13 1189.96 20 14.55 2160 629 3.67 / 468.92 5 79
5 13 639.00 20 14.67 1368 401 4.08 / 469.32 5 86
6 13 96.24 20 14.88 488 145 4.22 / 469.46 6 74
7 13 22.92 20 14.91 344 103 4.32 / 469.57 6 67
8 8 0.08 244 14.87 303 1099 5.42 / 470.67 6 142
Average= 5.41
(KJ/cycle)

Cycle 85 GMT 26/ 3/2022 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 28 14.86 460 191 0.19 / 461.29 6 14
2 7 1172.16 41 14.85 2120 1291 1.48 / 462.58 14 73
3 13 1106.80 20 14.83 2027 601 2.08 / 463.18 5 77
4 13 1011.20 20 14.80 1883 557 2.64 / 463.74 5 78
5 13 240.52 20 14.93 735 219 2.86 / 463.96 6 81
6 13 64.16 20 14.96 415 124 2.98 / 464.08 6 69
7 13 15.36 20 14.97 330 99 3.08 / 464.18 6 65
8 8 0.00 234 14.91 305 1064 4.15 / 465.24 6 141
Average= 5.41
(KJ/cycle)

Cycle 84 GMT 16/ 3/2022 22:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 28 14.85 478 199 0.20 / 456.37 6 13
2 7 1587.20 40 14.66 2726 1599 1.80 / 457.96 13 68
3 13 1506.48 20 14.63 2627 769 2.57 / 458.73 5 73
4 13 1197.88 20 14.64 2167 634 3.20 / 459.37 5 79
5 13 640.36 20 14.72 1358 400 3.60 / 459.77 5 89
6 13 72.68 20 14.90 445 133 3.73 / 459.90 6 73
7 8 0.00 257 14.87 313 1196 4.93 / 461.10 6 130
Average= 5.42
(KJ/cycle)

Cycle 83 GMT 6/ 3/2022 23:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 28 14.87 447 186 0.19 / 451.90 6 13
2 7 1402.72 40 14.75 2444 1442 1.63 / 453.34 13 70
3 13 1326.96 20 14.73 2372 699 2.33 / 454.04 5 75
4 13 931.76 20 14.74 1786 527 2.85 / 454.57 5 85
5 13 369.64 20 14.84 942 280 3.13 / 454.85 5 87
6 13 63.88 20 14.92 428 128 3.26 / 454.98 6 72
7 8 -0.04 255 14.88 314 1191 4.45 / 456.17 6 129
Average= 5.43
(KJ/cycle)

Cycle 82 GMT 25/ 2/2022 0: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 28 14.87 487 203 0.20 / 446.66 6 13
2 7 1926.56 40 14.53 3195 1857 2.06 / 448.52 13 65
3 13 1830.16 20 14.50 3078 893 2.95 / 449.41 5 69
4 13 1192.20 20 14.56 2172 632 3.58 / 450.04 5 82
5 13 533.36 20 14.72 1182 348 3.93 / 450.39 5 88
6 13 60.80 20 14.89 406 121 4.05 / 450.51 6 68
7 13 16.32 20 14.90 333 99 4.15 / 450.61 6 65
8 8 0.00 242 14.85 307 1103 5.26 / 451.71 6 134
Average= 5.44
(KJ/cycle)

Cycle 81 GMT 14/ 2/2022 23:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 28 14.86 468 195 0.19 / 441.08 6 13
2 3 1023.40 1 15.01 1933 29 0.22 / 441.11 5 26
3 7 2004.72 40 14.51 3306 1919 2.14 / 443.02 26 58
4 13 1817.88 20 14.49 3068 889 3.03 / 443.91 5 65
5 13 1373.36 20 14.51 2461 714 3.75 / 444.63 5 76
6 13 689.60 20 14.66 1441 423 4.17 / 445.05 5 87
7 13 59.28 20 14.90 429 128 4.30 / 445.18 6 69
8 13 16.48 20 14.91 356 106 4.40 / 445.28 6 66
9 8 -0.08 244 14.85 324 1174 5.58 / 446.46 6 142
Average= 5.44
(KJ/cycle)

Cycle 80 GMT 5/ 2/2022 2: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 31 14.87 471 217 0.22 / 435.61 6 14
2 3 878.44 -2 15.37 2 0 0.00 / 435.61 6 14
3 7 2005.16 40 14.51 3338 1937 2.15 / 437.55 14 58
4 13 1803.12 20 14.50 3064 889 3.04 / 438.44 5 64
5 13 1256.00 20 14.55 2283 664 3.71 / 439.10 5 78
6 13 600.60 20 14.69 1305 383 4.09 / 439.49 5 85
7 13 74.20 20 14.89 452 135 4.23 / 439.62 6 70
8 13 20.04 20 14.90 354 105 4.33 / 439.73 6 65
9 8 0.00 244 14.85 319 1156 5.49 / 440.88 6 142
Average= 5.44
(KJ/cycle)

Cycle 79 GMT 26/ 1/2022 4:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 32 14.88 469 223 0.22 / 430.00 6 14
2 7 2008.64 40 14.51 3312 1922 2.15 / 431.92 14 58
3 13 1916.20 20 14.48 3231 936 3.08 / 432.86 5 62
4 13 1383.00 20 14.51 2459 714 3.79 / 433.57 5 76
5 13 623.24 20 14.69 1343 395 4.19 / 433.96 5 87
6 13 92.12 20 14.89 489 146 4.34 / 434.11 6 72
7 13 22.72 20 14.91 361 108 4.44 / 434.22 6 65
8 8 0.12 246 14.86 322 1177 5.62 / 435.40 6 147
Average= 5.44
(KJ/cycle)

Cycle 78 GMT 16/ 1/2022 7: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 32 14.88 464 221 0.22 / 424.28 6 14
2 7 2012.80 41 14.51 3354 1995 2.22 / 426.28 14 58
3 13 1920.00 20 14.47 3240 938 3.15 / 427.21 5 63
4 13 1378.24 20 14.51 2463 715 3.87 / 427.93 5 75
5 13 727.48 20 14.66 1493 438 4.31 / 428.37 5 85
6 13 81.72 20 14.90 471 140 4.45 / 428.51 6 70
7 13 20.32 20 14.91 362 108 4.55 / 428.62 6 65
8 8 -0.04 244 14.86 320 1160 5.72 / 429.78 6 134
Average= 5.44
(KJ/cycle)

Cycle 77 GMT 6/ 1/2022 9:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 32 14.88 462 220 0.22 / 418.74 6 14
2 7 2013.48 40 14.51 3340 1939 2.16 / 420.68 14 55
3 13 1818.12 20 14.51 3075 892 3.05 / 421.57 5 65
4 13 1285.12 20 14.55 2291 667 3.72 / 422.24 5 76
5 13 747.88 20 14.65 1519 445 4.16 / 422.68 5 84
6 13 89.40 20 14.90 477 142 4.30 / 422.82 6 70
7 8 0.08 265 14.87 314 1237 5.54 / 424.06 6 139
Average= 5.44
(KJ/cycle)

Cycle 76 GMT 27/12/2021 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 31 14.89 451 208 0.21 / 413.20 6 14
2 7 2009.52 40 14.53 3317 1928 2.14 / 415.13 14 55
3 13 1919.12 20 14.50 3192 926 3.06 / 416.06 5 64
4 13 1278.04 20 14.55 2299 669 3.73 / 416.73 5 76
5 13 731.84 20 14.67 1488 437 4.17 / 417.16 5 84
6 13 86.76 20 14.90 461 137 4.30 / 417.30 6 70
7 13 20.96 20 14.92 345 103 4.41 / 417.40 6 64
8 8 0.04 244 14.88 307 1115 5.52 / 418.52 6 131
Average= 5.44
(KJ/cycle)

Cycle 75 GMT 17/12/2021 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 31 14.90 456 211 0.21 / 407.61 6 12
2 7 2007.40 41 14.52 3320 1976 2.19 / 409.58 12 59
3 13 1918.48 20 14.49 3196 926 3.11 / 410.51 5 62
4 13 1287.84 20 14.56 2304 671 3.78 / 411.18 5 75
5 13 748.56 20 14.66 1529 448 4.23 / 411.63 5 84
6 13 85.68 20 14.90 472 141 4.37 / 411.77 6 72
7 13 22.60 20 14.92 351 105 4.48 / 411.88 6 65
8 8 0.16 244 14.87 309 1121 5.60 / 413.00 6 133
Average= 5.43
(KJ/cycle)

Cycle 74 GMT 7/12/2021 17:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 31 14.89 450 208 0.21 / 402.02 6 13
2 7 2004.92 40 14.53 3346 1945 2.15 / 403.96 13 56
3 13 1918.68 20 14.51 3221 935 3.09 / 404.90 5 62
4 13 1384.44 20 14.54 2440 710 3.80 / 405.61 5 75
5 13 729.68 20 14.68 1494 439 4.24 / 406.04 5 85
6 13 91.64 20 14.91 478 143 4.38 / 406.19 6 72
7 13 11.20 20 14.94 324 97 4.47 / 406.28 6 63
8 8 0.04 246 14.89 304 1114 5.59 / 407.40 6 144
Average= 5.43
(KJ/cycle)

Cycle 73 GMT 27/11/2021 20:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 31 14.89 468 216 0.22 / 396.31 6 12
2 7 2007.76 40 14.53 3347 1945 2.16 / 398.25 12 55
3 13 1911.36 20 14.51 3207 931 3.09 / 399.18 5 64
4 13 1485.08 20 14.51 2593 752 3.84 / 399.94 5 73
5 13 795.88 20 14.66 1591 466 4.31 / 400.40 5 86
6 13 110.68 20 14.90 524 156 4.47 / 400.56 6 79
7 13 28.92 20 14.93 361 108 4.57 / 400.67 6 70
8 8 -0.04 246 14.88 312 1142 5.72 / 401.81 6 141
Average= 5.43
(KJ/cycle)

Cycle 72 GMT 17/11/2021 23:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 31 14.90 468 216 0.22 / 390.69 6 12
2 7 2005.48 40 14.54 3317 1929 2.15 / 392.62 12 56
3 13 1917.36 20 14.50 3211 931 3.08 / 393.55 5 64
4 13 1279.76 20 14.56 2302 670 3.75 / 394.22 5 78
5 13 743.72 20 14.67 1515 445 4.19 / 394.66 5 84
6 13 95.32 20 14.91 501 149 4.34 / 394.81 6 76
7 8 0.04 265 14.89 324 1278 5.62 / 396.09 6 135
Average= 5.43
(KJ/cycle)

Cycle 71 GMT 8/11/2021 2: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 31 14.91 458 212 0.21 / 385.02 6 12
2 7 2008.12 40 14.53 3344 1944 2.16 / 386.96 12 58
3 13 1919.20 20 14.51 3226 936 3.09 / 387.90 5 63
4 13 1370.60 20 14.55 2429 707 3.80 / 388.60 5 76
5 13 825.48 20 14.65 1637 480 4.28 / 389.08 5 85
6 13 83.80 20 14.92 475 142 4.42 / 389.23 6 74
7 8 0.08 265 14.89 316 1247 5.67 / 390.47 6 141
Average= 5.42
(KJ/cycle)

Cycle 70 GMT 29/10/2021 4:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 31 14.90 482 223 0.22 / 379.42 6 13
2 7 2009.20 40 14.52 3335 1937 2.16 / 381.36 13 57
3 13 1916.72 20 14.50 3238 939 3.10 / 382.30 5 63
4 13 1280.68 20 14.56 2313 674 3.77 / 382.97 5 78
5 13 744.80 20 14.68 1516 445 4.22 / 383.42 5 87
6 13 87.04 20 14.92 482 144 4.36 / 383.56 6 77
7 8 0.12 263 14.90 318 1246 5.61 / 384.81 6 134
Average= 5.42
(KJ/cycle)

Cycle 69 GMT 19/10/2021 7:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 32 14.91 470 224 0.22 / 373.78 6 12
2 7 2009.52 40 14.53 3324 1932 2.16 / 375.71 12 58
3 13 1914.12 20 14.51 3199 928 3.08 / 376.64 5 63
4 13 1291.32 20 14.57 2311 673 3.76 / 377.31 5 77
5 13 852.88 20 14.65 1684 493 4.25 / 377.81 5 85
6 13 85.72 20 14.92 478 143 4.39 / 377.95 6 76
7 8 0.08 263 14.90 319 1250 5.64 / 379.20 6 132
Average= 5.42
(KJ/cycle)

Cycle 68 GMT 9/10/2021 10:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 32 14.92 463 221 0.22 / 368.12 6 11
2 7 2014.88 41 14.52 3365 2003 2.22 / 370.12 11 58
3 13 1918.52 20 14.52 3197 928 3.15 / 371.05 5 65
4 13 1366.48 20 14.56 2436 709 3.86 / 371.76 5 76
5 13 620.36 20 14.73 1338 394 4.26 / 372.15 5 87
6 13 87.96 20 14.93 484 145 4.40 / 372.30 6 75
7 8 0.08 264 14.91 319 1256 5.66 / 373.55 6 137
Average= 5.41
(KJ/cycle)

Cycle 67 GMT 29/ 9/2021 12:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 32 14.92 469 224 0.22 / 362.56 6 12
2 7 2005.68 40 14.54 3333 1938 2.16 / 364.49 12 57
3 13 1813.60 20 14.53 3050 886 3.05 / 365.38 5 64
4 13 1297.08 20 14.57 2319 676 3.72 / 366.06 5 77
5 13 739.28 20 14.70 1493 439 4.16 / 366.50 5 86
6 13 80.96 20 14.93 477 142 4.31 / 366.64 6 75
7 8 0.08 261 14.91 324 1261 5.57 / 367.90 6 134
Average= 5.41
(KJ/cycle)

Cycle 66 GMT 19/ 9/2021 15:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 32 14.93 467 223 0.22 / 356.87 6 12
2 7 2003.32 40 14.56 3303 1924 2.15 / 358.79 12 57
3 13 1911.96 20 14.52 3224 936 3.08 / 359.73 5 65
4 13 1282.52 20 14.58 2302 671 3.75 / 360.40 5 76
5 13 855.52 20 14.66 1680 493 4.25 / 360.89 5 84
6 13 89.92 20 14.94 490 146 4.39 / 361.04 6 73
7 13 22.96 20 14.96 367 110 4.50 / 361.15 6 66
8 8 0.04 246 14.91 323 1185 5.69 / 362.33 6 137
Average= 5.41
(KJ/cycle)

Cycle 65 GMT 9/ 9/2021 18:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 32 14.93 470 225 0.22 / 351.18 6 11
2 7 2014.80 40 14.56 3316 1931 2.16 / 353.11 11 57
3 13 1923.68 20 14.53 3220 936 3.09 / 354.05 5 64
4 13 1381.80 20 14.57 2442 712 3.80 / 354.76 5 75
5 13 725.76 20 14.71 1485 437 4.24 / 355.20 5 84
6 13 83.84 20 14.95 480 144 4.38 / 355.34 6 73
7 13 26.08 20 14.97 375 112 4.50 / 355.45 6 66
8 8 0.08 246 14.92 324 1189 5.68 / 356.64 6 135
Average= 5.40
(KJ/cycle)

Cycle 64 GMT 30/ 8/2021 21: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 32 14.94 480 229 0.23 / 345.56 6 12
2 7 2004.88 40 14.58 3300 1925 2.15 / 347.49 12 58
3 13 1913.44 20 14.55 3191 929 3.08 / 348.42 5 62
4 13 1281.28 20 14.60 2309 674 3.76 / 349.09 5 77
5 13 661.32 20 14.74 1379 407 4.16 / 349.50 5 85
6 13 104.80 20 14.94 514 154 4.32 / 349.65 6 79
7 13 25.12 20 14.96 378 113 4.43 / 349.76 6 70
8 8 0.04 246 14.91 326 1196 5.63 / 350.96 6 133
Average= 5.40
(KJ/cycle)

Cycle 63 GMT 20/ 8/2021 23:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 32 14.95 468 224 0.22 / 339.81 6 12
2 7 2005.04 40 14.56 3328 1938 2.16 / 341.75 8 58
3 13 1914.36 20 14.54 3197 930 3.09 / 342.68 5 64
4 13 1379.20 20 14.58 2441 712 3.80 / 343.39 5 74
5 13 829.68 20 14.68 1660 487 4.29 / 343.88 5 83
6 13 83.04 20 14.97 476 143 4.43 / 344.02 6 74
7 13 27.40 20 14.98 380 114 4.55 / 344.13 6 67
8 13 8.64 20 14.98 341 102 4.65 / 344.24 6 67
9 8 0.08 227 14.93 324 1098 5.75 / 345.33 6 135
Average= 5.40
(KJ/cycle)

Cycle 62 GMT 11/ 8/2021 2:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 31 14.95 473 219 0.22 / 334.15 6 12
2 3 1036.52 1 15.02 1967 30 0.25 / 334.17 5 37
3 7 2012.76 40 14.56 3326 1937 2.19 / 336.11 37 57
4 13 1914.24 20 14.55 3180 925 3.11 / 337.04 5 64
5 13 1275.60 20 14.61 2300 672 3.78 / 337.71 5 78
6 13 735.00 20 14.72 1516 446 4.23 / 338.16 5 86
7 13 83.36 20 14.97 480 144 4.37 / 338.30 6 75
8 13 27.32 20 14.98 374 112 4.49 / 338.41 6 69
9 8 0.08 242 14.93 325 1174 5.66 / 339.59 6 131
Average= 5.39
(KJ/cycle)

Cycle 61 GMT 1/ 8/2021 5:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 31 14.95 483 224 0.22 / 328.46 6 13
2 7 2014.40 40 14.57 3327 1939 2.16 / 330.40 13 59
3 13 1920.76 20 14.53 3194 928 3.09 / 331.33 5 63
4 13 1384.36 20 14.58 2452 715 3.81 / 332.04 5 76
5 13 736.04 20 14.73 1508 444 4.25 / 332.49 5 86
6 13 92.00 20 14.97 497 149 4.40 / 332.64 6 79
7 13 25.84 20 14.99 376 113 4.51 / 332.75 6 71
8 8 0.04 244 14.94 323 1177 5.69 / 333.93 6 132
Average= 5.39
(KJ/cycle)

Cycle 60 GMT 22/ 7/2021 8: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 31 14.96 473 219 0.22 / 323.02 6 13
2 7 1846.68 40 14.61 3087 1804 2.02 / 324.82 13 68
3 13 1776.40 20 14.59 3002 876 2.90 / 325.70 5 73
4 13 1254.80 20 14.63 2272 665 3.56 / 326.36 5 82
5 13 711.52 20 14.75 1485 438 4.00 / 326.80 5 89
6 13 80.16 20 14.98 474 142 4.14 / 326.94 6 76
7 13 27.56 20 14.99 382 115 4.26 / 327.05 6 69
8 8 0.08 242 14.94 327 1182 5.44 / 328.24 6 131
Average= 5.38
(KJ/cycle)

Cycle 59 GMT 12/ 7/2021 7:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 31 14.96 484 224 0.22 / 317.45 6 12
2 7 2004.68 40 14.56 3320 1934 2.16 / 319.38 12 61
3 13 1825.44 20 14.53 3095 899 3.06 / 320.28 5 69
4 13 1200.28 20 14.62 2204 644 3.70 / 320.92 5 81
5 13 657.76 20 14.77 1397 413 4.11 / 321.34 5 88
6 13 95.76 20 14.97 507 152 4.27 / 321.49 6 83
7 13 25.24 20 14.99 378 113 4.38 / 321.60 6 76
8 8 0.24 240 14.94 333 1194 5.57 / 322.80 6 132
Average= 5.38
(KJ/cycle)

Cycle 58 GMT 2/ 7/2021 10:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 31 14.98 463 215 0.22 / 312.72 6 12
2 7 1392.16 40 14.81 2443 1447 1.66 / 314.17 12 72
3 13 1322.32 20 14.79 2355 697 2.36 / 314.87 5 76
4 13 1028.92 20 14.80 1925 570 2.93 / 315.44 5 82
5 13 597.40 20 14.85 1314 390 3.32 / 315.83 5 88
6 13 64.00 20 15.02 447 134 3.45 / 315.96 6 77
7 13 35.32 20 15.02 396 119 3.57 / 316.08 6 74
8 8 0.08 235 14.97 325 1143 4.72 / 317.22 6 131
Average= 5.38
(KJ/cycle)

Cycle 57 GMT 22/ 6/2021 10:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 31 14.98 472 219 0.22 / 307.35 6 12
2 7 1885.56 40 14.61 3140 1835 2.05 / 309.18 12 61
3 13 1792.40 20 14.59 3047 889 2.94 / 310.07 5 67
4 13 1239.76 20 14.64 2261 662 3.61 / 310.73 5 81
5 13 598.60 20 14.80 1300 385 3.99 / 311.12 5 87
6 13 80.12 20 15.00 459 138 4.13 / 311.26 6 74
7 13 25.88 20 15.01 364 109 4.24 / 311.37 6 68
8 8 0.08 242 14.97 315 1141 5.38 / 312.51 6 142
Average= 5.39
(KJ/cycle)

Cycle 56 GMT 12/ 6/2021 10:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 31 14.99 463 215 0.22 / 301.93 6 13
2 7 1790.64 40 14.65 3015 1767 1.98 / 303.69 13 66
3 13 1707.64 20 14.64 2901 849 2.83 / 304.54 5 71
4 13 1395.44 20 14.62 2463 720 3.55 / 305.26 5 79
5 13 825.68 20 14.74 1637 483 4.03 / 305.74 5 87
6 13 74.32 20 15.01 452 136 4.17 / 305.88 6 72
7 13 26.12 20 15.02 366 110 4.28 / 305.99 6 67
8 8 0.08 242 14.98 314 1138 5.42 / 307.13 6 145
Average= 5.39
(KJ/cycle)

Cycle 55 GMT 2/ 6/2021 10:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 31 15.00 470 219 0.22 / 296.26 6 12
2 7 2006.16 40 14.57 3334 1943 2.16 / 298.20 12 58
3 13 1911.92 20 14.55 3197 930 3.09 / 299.13 5 64
4 13 1466.20 20 14.58 2566 748 3.84 / 299.88 5 76
5 13 675.16 20 14.79 1423 421 4.26 / 300.30 5 86
6 13 113.20 20 15.00 531 159 4.42 / 300.46 6 75
7 13 29.16 20 15.03 359 108 4.53 / 300.57 6 66
8 8 0.00 244 14.98 313 1144 5.67 / 301.71 6 134
Average= 5.39
(KJ/cycle)

Cycle 54 GMT 23/ 5/2021 13: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 31 15.00 469 218 0.22 / 290.53 6 12
2 7 2008.32 40 14.57 3338 1945 2.16 / 292.48 12 58
3 13 1921.56 20 14.54 3236 941 3.10 / 293.42 5 64
4 13 1380.80 20 14.61 2453 717 3.82 / 294.14 5 76
5 13 828.96 20 14.74 1643 484 4.31 / 294.62 5 85
6 13 89.88 20 15.02 480 144 4.45 / 294.76 6 68
7 13 29.08 20 15.04 366 110 4.56 / 294.87 6 61
8 8 0.00 244 14.99 318 1163 5.72 / 296.04 6 137
Average= 5.38
(KJ/cycle)

Cycle 53 GMT 13/ 5/2021 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 31 15.01 465 216 0.22 / 284.85 6 13
2 7 2005.60 40 14.57 3327 1939 2.16 / 286.79 7 59
3 13 1918.12 20 14.56 3187 928 3.08 / 287.72 5 65
4 13 1379.84 20 14.62 2444 715 3.80 / 288.43 5 77
5 13 727.80 20 14.78 1502 444 4.24 / 288.88 5 87
6 13 161.00 20 14.99 608 182 4.42 / 289.06 6 78
7 13 18.48 20 15.04 344 103 4.53 / 289.16 6 66
8 8 -0.04 246 15.00 312 1151 5.68 / 290.31 6 147
Average= 5.38
(KJ/cycle)

Cycle 52 GMT 3/ 5/2021 18:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 31 15.01 472 220 0.22 / 279.30 6 13
2 7 2009.16 40 14.58 3325 1939 2.16 / 281.24 13 56
3 13 1927.04 20 14.55 3240 943 3.10 / 282.19 5 63
4 13 1282.80 20 14.65 2312 677 3.78 / 282.86 5 78
5 13 557.20 20 14.86 1238 368 4.15 / 283.23 5 86
6 13 127.24 20 15.01 550 165 4.31 / 283.40 6 76
7 13 30.64 20 15.05 358 108 4.42 / 283.50 6 65
8 8 0.12 244 15.00 309 1131 5.55 / 284.64 6 139
Average= 5.37
(KJ/cycle)

Cycle 51 GMT 23/ 4/2021 21:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 30 15.02 469 211 0.21 / 273.63 6 12
2 7 2009.04 40 14.60 3313 1935 2.15 / 275.56 6 57
3 13 1925.96 20 14.56 3213 936 3.08 / 276.50 5 63
4 13 1402.80 20 14.62 2466 721 3.80 / 277.22 5 77
5 13 747.56 20 14.78 1531 453 4.26 / 277.67 5 87
6 13 109.28 20 15.03 518 156 4.41 / 277.82 6 73
7 13 29.88 20 15.05 366 110 4.52 / 277.94 6 65
8 8 0.00 244 15.01 314 1150 5.67 / 279.09 6 138
Average= 5.37
(KJ/cycle)

Cycle 50 GMT 14/ 4/2021 0:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 31 15.02 478 223 0.22 / 268.03 6 13
2 7 2003.32 40 14.59 3322 1939 2.16 / 269.97 13 56
3 13 1907.72 20 14.56 3224 939 3.10 / 270.90 5 66
4 13 1269.36 20 14.66 2282 669 3.77 / 271.57 5 81
5 13 721.64 20 14.80 1479 438 4.21 / 272.01 5 86
6 13 98.12 20 15.04 496 149 4.36 / 272.16 6 69
7 8 0.12 265 15.02 315 1254 5.61 / 273.41 6 138
Average= 5.36
(KJ/cycle)

Cycle 49 GMT 4/ 4/2021 2:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 31 15.02 475 221 0.22 / 262.23 6 14
2 7 2003.60 40 14.60 3326 1942 2.16 / 264.17 14 57
3 13 1917.08 20 14.57 3220 938 3.10 / 265.11 5 62
4 13 1482.88 20 14.60 2607 761 3.86 / 265.87 5 74
5 13 801.84 20 14.78 1611 476 4.34 / 266.35 5 85
6 13 132.16 20 15.03 566 170 4.51 / 266.52 6 80
7 13 29.84 20 15.06 377 114 4.62 / 266.63 6 69
8 8 0.08 244 15.01 320 1172 5.79 / 267.80 6 131
Average= 5.36
(KJ/cycle)

Cycle 48 GMT 25/ 3/2021 5:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 31 15.03 477 222 0.22 / 256.49 6 13
2 7 2012.80 41 14.59 3346 2002 2.22 / 258.49 13 58
3 13 1914.36 20 14.57 3212 936 3.16 / 259.42 5 65
4 13 1377.92 20 14.64 2440 714 3.87 / 260.14 5 78
5 13 711.24 20 14.82 1466 435 4.31 / 260.57 5 86
6 13 139.64 20 15.03 567 170 4.48 / 260.74 6 77
7 13 16.28 20 15.07 348 105 4.58 / 260.85 6 64
8 8 0.00 244 15.02 317 1162 5.75 / 262.01 6 134
Average= 5.35
(KJ/cycle)

Cycle 47 GMT 15/ 3/2021 8:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 31 15.04 471 220 0.22 / 250.75 6 14
2 7 2011.76 40 14.59 3327 1942 2.16 / 252.69 14 57
3 13 1919.44 20 14.56 3225 939 3.10 / 253.63 5 64
4 13 1391.00 20 14.65 2443 716 3.82 / 254.35 5 76
5 13 842.12 20 14.77 1667 492 4.31 / 254.84 5 86
6 13 153.96 20 15.03 595 179 4.49 / 255.02 6 79
7 8 0.08 263 15.04 314 1242 5.73 / 256.26 6 132
Average= 5.34
(KJ/cycle)

Cycle 46 GMT 5/ 3/2021 11:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 31 15.04 474 221 0.22 / 245.08 6 13
2 7 2008.92 40 14.60 3345 1953 2.17 / 247.03 13 56
3 13 1919.52 20 14.58 3210 936 3.11 / 247.97 5 64
4 13 1297.84 20 14.68 2340 687 3.80 / 248.65 5 77
5 13 660.52 20 14.85 1403 417 4.21 / 249.07 5 86
6 13 99.28 20 15.06 504 152 4.37 / 249.22 6 71
7 13 24.60 20 15.08 376 113 4.48 / 249.34 6 64
8 8 -0.04 246 15.03 324 1198 5.68 / 250.53 6 149
Average= 5.33
(KJ/cycle)

Cycle 45 GMT 23/ 2/2021 13:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 31 15.04 475 221 0.22 / 239.33 6 13
2 7 2012.16 40 14.60 3349 1956 2.18 / 241.29 6 57
3 13 1914.12 20 14.60 3175 927 3.10 / 242.22 5 65
4 13 1390.08 20 14.65 2471 724 3.83 / 242.94 5 75
5 13 836.36 20 14.80 1660 491 4.32 / 243.43 5 86
6 13 87.32 20 15.07 475 143 4.46 / 243.57 6 72
7 13 24.52 20 15.09 360 109 4.57 / 243.68 6 66
8 8 0.04 246 15.04 317 1173 5.74 / 244.86 6 134
Average= 5.32
(KJ/cycle)

Cycle 44 GMT 13/ 2/2021 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 30 15.04 484 218 0.22 / 233.70 6 13
2 3 1032.88 1 15.06 1965 30 0.25 / 233.73 5 36
3 7 2010.04 40 14.60 3351 1957 2.20 / 235.69 36 59
4 13 1811.44 20 14.60 3070 896 3.10 / 236.58 5 66
5 13 1283.56 20 14.69 2311 679 3.78 / 237.26 5 78
6 13 652.68 20 14.86 1386 412 4.19 / 237.67 5 87
7 13 94.84 20 15.07 508 153 4.35 / 237.83 6 80
8 13 24.16 20 15.08 373 112 4.46 / 237.94 6 73
9 8 0.08 240 15.04 325 1173 5.63 / 239.11 6 139
Average= 5.31
(KJ/cycle)

Cycle 43 GMT 3/ 2/2021 19: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 30 15.05 470 212 0.21 / 228.18 6 13
2 7 2004.80 40 14.61 3310 1934 2.15 / 230.12 13 59
3 13 1808.68 20 14.60 3046 889 3.04 / 231.01 5 69
4 13 1182.12 20 14.72 2170 639 3.67 / 231.65 5 81
5 13 645.48 20 14.87 1367 407 4.08 / 232.05 5 89
6 13 89.20 20 15.07 486 146 4.23 / 232.20 6 81
7 13 26.12 20 15.09 374 113 4.34 / 232.31 6 72
8 8 -0.04 240 15.04 324 1170 5.51 / 233.48 6 130
Average= 5.31
(KJ/cycle)

Cycle 42 GMT 24/ 1/2021 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 30 15.05 483 218 0.22 / 222.96 6 14
2 7 1747.72 40 14.70 2958 1739 1.96 / 224.70 14 69
3 13 1662.12 20 14.68 2841 834 2.79 / 225.54 5 71
4 13 1155.60 20 14.75 2124 627 3.42 / 226.16 5 82
5 13 618.00 20 14.89 1329 396 3.81 / 226.56 5 89
6 13 77.64 20 15.09 470 142 3.96 / 226.70 6 80
7 8 0.04 259 15.05 326 1271 5.23 / 227.97 6 131
Average= 5.30
(KJ/cycle)

Cycle 41 GMT 14/ 1/2021 21:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 30 15.05 476 215 0.21 / 217.76 6 12
2 7 1714.56 40 14.72 2905 1710 1.93 / 219.47 12 68
3 13 1629.60 20 14.71 2789 821 2.75 / 220.29 5 72
4 13 1207.24 20 14.74 2211 652 3.40 / 220.94 5 81
5 13 650.24 20 14.88 1384 412 3.81 / 221.35 5 89
6 13 86.72 20 15.09 486 147 3.96 / 221.50 6 81
7 8 0.20 257 15.06 322 1246 5.20 / 222.74 6 135
Average= 5.30
(KJ/cycle)

Cycle 40 GMT 4/ 1/2021 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 30 15.06 488 220 0.22 / 212.18 6 12
2 7 1944.04 40 14.63 3245 1899 2.12 / 214.08 12 61
3 13 1851.44 20 14.62 3133 916 3.04 / 215.00 5 69
4 13 1226.44 20 14.71 2241 659 3.69 / 215.66 5 82
5 13 681.56 20 14.86 1430 425 4.12 / 216.08 5 89
6 13 117.52 20 15.07 533 161 4.28 / 216.24 6 81
7 13 14.04 20 15.10 355 107 4.39 / 216.35 6 71
8 8 -0.04 242 15.05 327 1191 5.58 / 217.54 6 131
Average= 5.31
(KJ/cycle)

Cycle 39 GMT 25/12/2020 21:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 30 15.06 474 214 0.21 / 207.09 6 12
2 7 1667.96 40 14.73 2847 1677 1.89 / 208.77 12 69
3 13 1585.96 20 14.72 2739 806 2.70 / 209.57 5 72
4 13 1260.60 20 14.74 2273 670 3.37 / 210.24 5 83
5 13 488.76 20 14.96 1121 335 3.70 / 210.58 5 90
6 13 79.76 20 15.10 463 140 3.84 / 210.72 6 78
7 8 0.00 259 15.07 319 1245 5.09 / 211.96 6 136
Average= 5.30
(KJ/cycle)

Cycle 38 GMT 15/12/2020 21:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 30 15.06 485 219 0.22 / 201.70 6 15
2 7 1833.48 40 14.67 3075 1804 2.02 / 203.51 15 65
3 13 1742.24 20 14.64 2981 873 2.90 / 204.38 5 71
4 13 1197.12 20 14.73 2190 645 3.54 / 205.03 5 83
5 13 644.48 20 14.89 1372 409 3.95 / 205.44 5 89
6 13 91.48 20 15.08 497 150 4.10 / 205.59 6 82
7 8 0.04 261 15.06 328 1289 5.39 / 206.87 6 140
Average= 5.30
(KJ/cycle)

Cycle 37 GMT 5/12/2020 21:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 30 15.07 475 215 0.21 / 196.60 6 12
2 7 1720.56 40 14.73 2902 1710 1.92 / 198.31 12 66
3 13 1622.52 20 14.72 2779 818 2.74 / 199.13 5 74
4 13 1095.44 20 14.79 2031 601 3.34 / 199.73 5 84
5 13 564.20 20 14.93 1231 368 3.71 / 200.10 5 90
6 13 57.52 20 15.11 428 129 3.84 / 200.22 6 79
7 8 -0.08 259 15.07 323 1261 5.10 / 201.49 6 134
Average= 5.30
(KJ/cycle)

Cycle 36 GMT 25/11/2020 21:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 30 15.07 463 209 0.21 / 191.58 6 12
2 7 1640.68 40 14.76 2802 1654 1.86 / 193.24 12 68
3 13 1562.80 20 14.76 2692 795 2.66 / 194.03 5 72
4 13 1155.12 20 14.80 2107 624 3.28 / 194.66 5 81
5 13 510.76 20 14.96 1157 346 3.63 / 195.00 5 90
6 13 77.00 20 15.11 461 139 3.77 / 195.14 6 80
7 13 20.40 20 15.12 366 111 3.88 / 195.25 6 72
8 8 0.00 235 15.08 319 1130 5.01 / 196.38 6 140
Average= 5.31
(KJ/cycle)

Cycle 35 GMT 15/11/2020 21:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 31 15.08 466 218 0.22 / 186.35 6 11
2 7 1644.88 40 14.77 2806 1658 1.88 / 188.01 11 69
3 13 1567.04 20 14.74 2710 799 2.67 / 188.81 5 72
4 13 1255.84 20 14.76 2264 668 3.34 / 189.47 5 80
5 13 813.36 20 14.86 1623 482 3.83 / 189.96 5 88
6 13 51.96 20 15.12 428 129 3.95 / 190.09 6 77
7 13 28.72 20 15.12 383 116 4.07 / 190.20 6 74
8 8 -0.04 238 15.08 327 1174 5.24 / 191.38 6 135
Average= 5.32
(KJ/cycle)

Cycle 34 GMT 5/11/2020 21:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 31 15.09 462 216 0.22 / 180.76 6 11
2 7 2009.56 40 14.63 3326 1946 2.16 / 182.71 11 58
3 13 1918.68 20 14.62 3190 933 3.10 / 183.64 5 64
4 13 1172.96 20 14.75 2152 635 3.73 / 184.28 5 80
5 13 647.04 20 14.90 1373 409 4.14 / 184.69 5 88
6 13 87.80 20 15.10 490 148 4.29 / 184.83 6 76
7 13 23.48 20 15.12 370 112 4.40 / 184.95 6 71
8 8 -0.04 242 15.08 325 1186 5.59 / 186.13 6 140
Average= 5.32
(KJ/cycle)

Cycle 33 GMT 27/10/2020 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 31 15.10 463 217 0.22 / 175.16 6 11
2 7 2011.44 40 14.63 3329 1948 2.16 / 177.11 11 57
3 13 1915.84 20 14.61 3221 941 3.11 / 178.05 5 64
4 13 1267.60 20 14.73 2275 670 3.78 / 178.72 5 81
5 13 622.48 20 14.92 1325 395 4.17 / 179.12 5 87
6 13 84.28 20 15.12 474 143 4.31 / 179.26 6 74
7 13 24.08 20 15.13 365 110 4.43 / 179.37 6 67
8 8 -0.04 244 15.08 319 1174 5.60 / 180.55 6 135
Average= 5.31
(KJ/cycle)

Cycle 32 GMT 17/10/2020 3:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 31 15.09 468 219 0.22 / 169.50 6 11
2 7 2006.04 40 14.63 3330 1949 2.17 / 171.45 11 59
3 13 1917.60 20 14.62 3178 929 3.10 / 172.38 5 64
4 13 1286.88 20 14.73 2307 680 3.78 / 173.06 5 78
5 13 847.48 20 14.84 1658 492 4.27 / 173.55 5 85
6 13 82.00 20 15.12 463 140 4.41 / 173.69 6 73
7 13 23.56 20 15.14 356 108 4.52 / 173.80 6 67
8 8 0.04 244 15.09 311 1145 5.66 / 174.95 6 137
Average= 5.30
(KJ/cycle)

Cycle 31 GMT 7/10/2020 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 29 15.11 476 209 0.21 / 163.77 6 10
2 3 1042.88 1 15.10 1954 30 0.24 / 163.80 5 40
3 7 2007.48 40 14.64 3329 1949 2.19 / 165.75 40 58
4 13 1918.68 20 14.62 3210 939 3.13 / 166.69 5 63
5 13 1374.76 20 14.71 2451 721 3.85 / 167.41 5 77
6 13 716.60 20 14.89 1474 439 4.29 / 167.85 5 86
7 13 75.92 20 15.13 466 141 4.43 / 167.99 6 73
8 13 26.36 20 15.14 375 114 4.54 / 168.10 6 68
9 8 0.04 244 15.09 322 1186 5.73 / 169.29 6 130
Average= 5.29
(KJ/cycle)

Cycle 30 GMT 27/ 9/2020 8:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 29 15.11 464 203 0.20 / 158.17 6 10
2 7 2007.00 40 14.64 3321 1945 2.15 / 160.11 10 57
3 13 1917.12 20 14.63 3223 943 3.09 / 161.06 5 64
4 13 1260.40 20 14.75 2256 666 3.76 / 161.72 5 79
5 13 718.08 20 14.90 1463 436 4.19 / 162.16 5 86
6 13 80.40 20 15.13 456 138 4.33 / 162.29 6 73
7 13 28.24 20 15.14 368 111 4.44 / 162.41 6 66
8 8 0.04 244 15.10 313 1153 5.60 / 163.56 6 142
Average= 5.28
(KJ/cycle)

Cycle 29 GMT 17/ 9/2020 11:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 29 15.10 477 209 0.21 / 152.65 6 10
2 7 2006.68 40 14.64 3327 1948 2.16 / 154.60 10 59
3 13 1908.16 20 14.63 3218 942 3.10 / 155.54 5 65
4 13 1168.44 20 14.77 2149 635 3.73 / 156.17 5 82
5 13 556.72 20 14.96 1220 365 4.10 / 156.54 5 89
6 13 66.64 20 15.14 440 133 4.23 / 156.67 6 72
7 13 27.04 20 15.15 369 112 4.34 / 156.78 6 65
8 8 0.00 244 15.10 320 1179 5.52 / 157.96 6 133
Average= 5.27
(KJ/cycle)

Cycle 28 GMT 7/ 9/2020 13:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 30 15.10 476 216 0.22 / 146.93 6 10
2 7 2010.64 40 14.64 3337 1954 2.17 / 148.89 10 59
3 13 1917.28 20 14.62 3200 936 3.11 / 149.82 5 65
4 13 1378.40 20 14.71 2458 723 3.83 / 150.55 5 79
5 13 714.76 20 14.90 1469 438 4.27 / 150.98 5 89
6 13 85.20 20 15.13 483 146 4.41 / 151.13 6 73
7 13 23.80 20 15.15 374 113 4.53 / 151.24 6 66
8 8 0.08 244 15.10 325 1197 5.72 / 152.44 6 144
Average= 5.26
(KJ/cycle)

Cycle 27 GMT 28/ 8/2020 16:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 30 15.10 482 218 0.22 / 141.69 6 11
2 7 1725.04 40 14.74 2915 1719 1.94 / 143.41 11 69
3 13 1635.44 20 14.74 2806 827 2.76 / 144.24 5 73
4 13 1211.92 20 14.79 2200 651 3.41 / 144.89 5 84
5 13 566.24 20 14.97 1242 372 3.79 / 145.26 5 90
6 13 105.40 20 15.13 513 155 3.94 / 145.42 6 82
7 13 28.68 20 15.15 383 116 4.06 / 145.53 6 72
8 8 0.04 240 15.10 327 1185 5.24 / 146.72 6 133
Average= 5.24
(KJ/cycle)

Cycle 26 GMT 18/ 8/2020 16:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 30 15.11 483 219 0.22 / 136.67 6 11
2 7 1653.32 40 14.79 2815 1665 1.88 / 138.33 11 68
3 13 1446.68 20 14.80 2536 751 2.63 / 139.08 5 77
4 13 1136.72 20 14.82 2103 623 3.26 / 139.71 5 83
5 13 486.12 20 15.00 1130 339 3.60 / 140.04 5 90
6 13 68.56 20 15.15 456 138 3.74 / 140.18 6 80
7 13 20.40 20 15.16 371 112 3.85 / 140.30 6 73
8 8 0.00 238 15.11 328 1180 5.03 / 141.47 6 142
Average= 5.24
(KJ/cycle)

Cycle 25 GMT 8/ 8/2020 16:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 30 15.12 478 217 0.22 / 131.64 6 11
2 7 1563.80 41 14.83 2688 1634 1.85 / 133.28 11 70
3 13 1494.24 20 14.80 2613 773 2.62 / 134.05 5 73
4 13 1083.52 20 14.86 2017 599 3.22 / 134.65 5 81
5 13 538.56 20 15.00 1209 363 3.59 / 135.01 5 89
6 13 53.36 20 15.16 428 130 3.72 / 135.14 6 76
7 13 32.28 20 15.16 394 119 3.84 / 135.26 6 74
8 8 -0.04 238 15.11 329 1183 5.02 / 136.45 6 136
Average= 5.25
(KJ/cycle)

Cycle 24 GMT 29/ 7/2020 16:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 30 15.12 478 217 0.22 / 126.47 6 11
2 7 1635.92 41 14.80 2795 1696 1.91 / 128.16 11 68
3 13 1555.16 20 14.77 2710 801 2.71 / 128.96 5 73
4 13 1131.00 20 14.84 2081 618 3.33 / 129.58 5 81
5 13 671.84 20 14.95 1407 421 3.75 / 130.00 5 89
6 13 88.80 20 15.15 485 147 3.90 / 130.15 6 80
7 13 30.76 20 15.16 387 117 4.02 / 130.27 6 72
8 8 -0.04 238 15.12 323 1162 5.18 / 131.43 6 136
Average= 5.26
(KJ/cycle)

Cycle 23 GMT 19/ 7/2020 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 30 15.13 475 216 0.22 / 120.84 6 10
2 7 2011.68 40 14.67 3326 1952 2.17 / 122.79 10 58
3 13 1819.00 20 14.67 3089 906 3.07 / 123.69 5 66
4 13 1205.20 20 14.78 2202 651 3.72 / 124.35 5 80
5 13 674.12 20 14.93 1418 423 4.15 / 124.77 5 88
6 13 100.24 20 15.14 514 156 4.30 / 124.92 6 80
7 13 30.28 20 15.16 386 117 4.42 / 125.04 6 71
8 8 0.00 246 15.11 325 1208 5.63 / 126.25 6 148
Average= 5.26
(KJ/cycle)

Cycle 22 GMT 9/ 7/2020 19:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 30 15.13 475 216 0.22 / 115.21 6 12
2 7 2007.68 41 14.66 3335 2005 2.22 / 117.21 12 59
3 13 1911.88 20 14.66 3196 937 3.16 / 118.15 5 64
4 13 1246.32 20 14.79 2235 661 3.82 / 118.81 5 80
5 13 597.04 20 14.97 1294 387 4.21 / 119.20 5 87
6 13 80.92 20 15.16 468 142 4.35 / 119.34 6 75
7 13 28.76 20 15.17 377 114 4.46 / 119.46 6 68
8 8 0.12 240 15.13 321 1166 5.63 / 120.62 6 132
Average= 5.24
(KJ/cycle)

Cycle 21 GMT 29/ 6/2020 21:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 30 15.13 480 218 0.22 / 109.51 6 11
2 7 2013.16 40 14.68 3325 1952 2.17 / 111.47 11 56
3 13 1917.72 20 14.66 3235 949 3.12 / 112.42 5 63
4 13 1374.96 20 14.75 2444 721 3.84 / 113.14 5 76
5 13 612.64 20 14.97 1315 394 4.23 / 113.53 5 87
6 13 86.24 20 15.16 483 146 4.38 / 113.68 6 75
7 13 26.52 20 15.17 377 114 4.49 / 113.79 6 68
8 8 0.08 246 15.13 323 1202 5.70 / 114.99 6 134
Average= 5.23
(KJ/cycle)

Cycle 20 GMT 20/ 6/2020 0:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 30 15.14 474 215 0.22 / 103.90 6 13
2 7 2004.96 40 14.68 3315 1947 2.16 / 105.84 13 57
3 13 1807.28 20 14.69 3058 898 3.06 / 106.74 5 66
4 13 1272.04 20 14.78 2291 677 3.74 / 107.42 5 78
5 13 715.52 20 14.93 1475 440 4.18 / 107.86 5 86
6 13 71.20 20 15.16 458 139 4.32 / 108.00 6 75
7 13 22.56 20 15.18 365 111 4.43 / 108.11 6 69
8 8 0.00 244 15.13 322 1189 5.62 / 109.30 6 140
Average= 5.20
(KJ/cycle)

Cycle 19 GMT 10/ 6/2020 3: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 30 15.14 471 214 0.21 / 98.31 6 10
2 7 2007.40 40 14.68 3326 1953 2.17 / 100.26 10 57
3 13 1917.68 20 14.66 3199 938 3.10 / 101.20 5 64
4 13 1162.68 20 14.83 2127 631 3.74 / 101.83 5 80
5 13 633.28 20 14.97 1348 404 4.14 / 102.23 5 87
6 13 52.52 20 15.18 428 130 4.27 / 102.36 6 71
7 13 16.40 20 15.18 364 111 4.38 / 102.47 6 68
8 8 0.08 244 15.14 327 1208 5.59 / 103.68 6 135
Average= 5.18
(KJ/cycle)

Cycle 18 GMT 31/ 5/2020 5:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 30 15.15 475 216 0.22 / 92.70 6 12
2 7 2012.28 40 14.69 3336 1960 2.18 / 94.66 12 58
3 13 1914.76 20 14.67 3222 945 3.12 / 95.60 5 64
4 13 1264.12 20 14.79 2313 684 3.81 / 96.29 5 78
5 13 530.16 20 15.01 1190 357 4.16 / 96.64 5 86
6 13 88.48 20 15.17 484 147 4.31 / 96.79 6 76
7 8 0.08 263 15.14 327 1302 5.61 / 98.09 6 143
Average= 5.16
(KJ/cycle)

Cycle 17 GMT 21/ 5/2020 7:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 30 15.15 474 215 0.22 / 87.04 6 14
2 7 2011.20 40 14.69 3345 1966 2.18 / 89.01 14 57
3 13 1825.28 20 14.69 3077 904 3.08 / 89.91 5 66
4 13 1385.80 20 14.76 2478 732 3.82 / 90.64 5 77
5 13 615.80 20 14.98 1335 400 4.22 / 91.04 5 87
6 13 78.84 20 15.17 474 144 4.36 / 91.19 6 74
7 8 0.04 261 15.15 327 1293 5.65 / 92.48 6 131
Average= 5.14
(KJ/cycle)

Cycle 16 GMT 11/ 5/2020 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 30 15.16 475 216 0.22 / 81.40 6 11
2 7 2004.28 40 14.69 3330 1957 2.17 / 83.36 11 58
3 13 1907.56 20 14.69 3203 941 3.11 / 84.30 5 64
4 13 1259.20 20 14.80 2286 677 3.79 / 84.98 5 78
5 13 617.52 20 14.99 1327 398 4.19 / 85.37 5 87
6 13 78.64 20 15.18 471 143 4.33 / 85.52 6 74
7 13 17.64 20 15.20 359 109 4.44 / 85.63 6 69
8 8 0.00 244 15.15 325 1201 5.64 / 86.83 6 141
Average= 5.11
(KJ/cycle)

Cycle 15 GMT 1/ 5/2020 13: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 30 15.16 469 213 0.21 / 75.74 6 12
2 7 2004.28 40 14.70 3324 1955 2.17 / 77.69 12 58
3 13 1906.44 20 14.70 3168 931 3.10 / 78.63 5 64
4 13 1264.28 20 14.80 2307 683 3.78 / 79.31 5 79
5 13 721.04 20 14.95 1489 445 4.23 / 79.75 5 87
6 13 73.16 20 15.19 464 141 4.37 / 79.89 6 73
7 8 0.20 263 15.16 324 1292 5.66 / 81.19 6 138
Average= 5.07
(KJ/cycle)

Cycle 14 GMT 21/ 4/2020 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 30 15.17 473 215 0.22 / 70.24 6 12
2 7 2002.76 40 14.70 3332 1959 2.17 / 72.20 12 58
3 13 1806.24 20 14.71 3068 903 3.08 / 73.11 5 66
4 13 1177.76 20 14.84 2165 643 3.72 / 73.75 5 80
5 13 541.80 20 15.02 1222 367 4.09 / 74.12 5 86
6 13 48.32 20 15.20 414 126 4.21 / 74.24 6 70
7 8 0.20 259 15.16 327 1284 5.50 / 75.53 6 138
Average= 5.04
(KJ/cycle)

Cycle 13 GMT 11/ 4/2020 18: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 30 15.17 478 218 0.22 / 64.64 6 14
2 7 2005.92 40 14.71 3339 1965 2.18 / 66.60 14 57
3 13 1913.84 20 14.70 3225 948 3.13 / 67.55 5 63
4 13 1173.16 20 14.85 2149 638 3.77 / 68.19 5 80
5 13 631.76 20 14.99 1361 408 4.18 / 68.60 5 86
6 13 84.48 20 15.19 485 147 4.32 / 68.74 6 74
7 8 0.04 263 15.17 322 1285 5.61 / 70.03 6 133
Average= 5.00
(KJ/cycle)

Cycle 12 GMT 1/ 4/2020 20:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 30 15.17 484 220 0.22 / 59.05 6 12
2 7 2011.28 40 14.70 3352 1971 2.19 / 61.02 12 58
3 13 1915.16 20 14.71 3209 944 3.14 / 61.96 5 63
4 13 1255.20 20 14.83 2271 674 3.81 / 62.64 5 78
5 13 507.68 20 15.04 1177 354 4.16 / 62.99 5 87
6 13 82.60 20 15.20 469 143 4.31 / 63.13 6 74
7 8 -0.08 261 15.17 325 1287 5.59 / 64.42 6 132
Average= 4.96
(KJ/cycle)

Cycle 11 GMT 22/ 3/2020 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 29 15.17 475 209 0.21 / 53.36 6 13
2 7 2004.24 40 14.71 3337 1963 2.17 / 55.32 13 58
3 13 1908.60 20 14.70 3231 950 3.12 / 56.27 5 64
4 13 1261.16 20 14.83 2276 675 3.80 / 56.94 5 79
5 13 705.32 20 14.97 1473 441 4.24 / 57.39 5 87
6 13 70.40 20 15.21 461 140 4.38 / 57.53 6 72
7 8 0.12 261 15.17 329 1303 5.68 / 58.83 6 134
Average= 4.90
(KJ/cycle)

Cycle 10 GMT 13/ 3/2020 1:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 29 15.17 479 211 0.21 / 47.86 6 13
2 7 2004.00 40 14.72 3325 1958 2.17 / 49.81 13 58
3 13 1807.40 20 14.74 3068 904 3.07 / 50.72 5 66
4 13 1171.48 20 14.86 2144 637 3.71 / 51.36 5 79
5 13 525.68 20 15.04 1205 362 4.07 / 51.72 5 88
6 13 85.60 20 15.20 478 145 4.22 / 51.86 6 76
7 8 -0.08 261 15.17 324 1283 5.50 / 53.15 6 142
Average= 4.83
(KJ/cycle)

Cycle 9 GMT 3/ 3/2020 4:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 29 15.18 481 212 0.21 / 42.23 6 15
2 7 2008.52 40 14.73 3326 1960 2.17 / 44.19 15 57
3 13 1811.80 20 14.74 3067 904 3.08 / 45.10 5 65
4 13 1268.44 20 14.83 2292 680 3.76 / 45.78 5 78
5 13 706.88 20 14.98 1473 441 4.20 / 46.22 5 87
6 13 62.64 20 15.21 446 136 4.33 / 46.35 6 72
7 8 0.12 261 15.18 326 1292 5.62 / 47.65 6 138
Average= 4.76
(KJ/cycle)

Cycle 8 GMT 22/ 2/2020 7: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 29 15.18 485 214 0.21 / 36.52 6 14
2 3 1019.76 1 15.20 1926 29 0.24 / 36.55 5 7
3 7 2010.28 40 14.73 3338 1967 2.21 / 38.52 7 57
4 13 1912.76 20 14.71 3225 949 3.16 / 39.47 5 63
5 13 1273.16 20 14.83 2318 688 3.85 / 40.15 5 78
6 13 631.68 20 15.01 1362 409 4.25 / 40.56 5 86
7 13 82.28 20 15.21 487 148 4.40 / 40.71 6 75
8 8 0.04 265 15.18 326 1311 5.71 / 42.02 6 133
Average= 4.67
(KJ/cycle)

Cycle 7 GMT 12/ 2/2020 9:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 29 15.18 486 214 0.21 / 30.74 6 14
2 7 2004.48 40 14.73 3327 1960 2.17 / 32.70 14 57
3 13 1911.00 20 14.73 3234 953 3.13 / 33.65 5 63
4 13 1341.00 20 14.82 2406 713 3.84 / 34.36 5 77
5 13 677.52 20 15.00 1438 431 4.27 / 34.79 5 87
6 13 57.12 20 15.22 445 135 4.41 / 34.93 6 70
7 13 17.68 20 15.23 379 115 4.52 / 35.05 6 66
8 8 0.04 246 15.18 338 1262 5.78 / 36.31 6 140
Average= 4.54
(KJ/cycle)

Cycle 6 GMT 2/ 2/2020 12:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 28 15.19 480 204 0.20 / 24.99 6 15
2 3 1034.92 1 15.18 1973 30 0.23 / 25.02 5 30
3 7 2003.88 40 14.73 3354 1976 2.21 / 26.99 30 57
4 13 1907.12 20 14.72 3221 948 3.16 / 27.94 5 63
5 13 1341.96 20 14.82 2423 718 3.88 / 28.66 5 77
6 13 565.20 20 15.04 1259 379 4.26 / 29.04 5 86
7 13 60.72 20 15.23 446 136 4.39 / 29.17 6 71
8 13 16.64 20 15.23 366 111 4.50 / 29.28 6 66
9 8 0.08 246 15.18 332 1240 5.74 / 30.52 6 134
Average= 4.36
(KJ/cycle)

Cycle 5 GMT 23/ 1/2020 14:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 31 15.20 490 231 0.23 / 19.38 6 15
2 3 909.72 -1 15.55 2 0 0.00 / 19.38 6 15
3 7 2004.64 40 14.74 3328 1962 2.19 / 21.34 15 57
4 13 1805.04 20 14.76 3073 907 3.10 / 22.25 5 66
5 13 1162.00 20 14.88 2152 640 3.74 / 22.89 5 79
6 13 613.32 20 15.03 1336 402 4.14 / 23.29 5 86
7 13 66.48 20 15.23 459 140 4.28 / 23.43 6 75
8 8 -0.16 265 15.19 336 1353 5.63 / 24.78 6 134
Average= 4.13
(KJ/cycle)

Cycle 4 GMT 13/ 1/2020 17:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 28 15.21 482 205 0.21 / 14.41 6 14
2 7 1520.56 40 14.96 2637 1578 1.78 / 15.99 14 62
3 13 1436.36 20 14.94 2530 756 2.54 / 16.75 5 66
4 13 1229.36 20 14.94 2229 666 3.21 / 17.41 5 72
5 13 349.56 20 15.17 929 282 3.49 / 17.69 5 82
6 13 57.00 20 15.27 442 135 3.62 / 17.83 6 72
7 8 0.08 259 15.22 334 1317 4.94 / 19.15 6 130
Average= 3.83
(KJ/cycle)

Cycle 3 GMT 12/ 1/2020 6:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 26 15.21 489 193 0.19 / 9.53 6 10
2 10 1006.84 3 15.17 1872 85 0.28 / 9.62 5 41
3 7 1505.28 40 14.95 2637 1577 1.86 / 11.20 41 61
4 13 1428.24 20 14.94 2522 754 2.61 / 11.95 5 66
5 13 994.76 20 15.00 1882 565 3.17 / 12.51 5 76
6 13 348.80 20 15.17 924 280 3.45 / 12.79 5 82
7 13 56.80 20 15.27 424 129 3.58 / 12.92 6 72
8 13 17.84 20 15.27 358 109 3.69 / 13.03 6 69
9 8 0.00 242 15.22 319 1175 4.87 / 14.21 6 133
Average= 3.55
(KJ/cycle)

Cycle 2 GMT 10/ 1/2020 20:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 31 15.24 480 227 0.23 / 4.88 6 12
2 3 890.20 -2 15.57 2 0 0.00 / 4.88 6 12
3 7 1424.88 40 14.99 2487 1491 1.72 / 6.37 12 64
4 13 1355.84 20 14.98 2384 714 2.43 / 7.09 5 68
5 13 1046.56 20 15.00 1962 589 3.02 / 7.68 5 75
6 13 279.52 20 15.20 814 247 3.27 / 7.92 5 82
7 13 42.60 20 15.28 402 123 3.39 / 8.05 6 70
8 8 -0.04 263 15.23 323 1294 4.68 / 9.34 6 132
Average= 3.11
(KJ/cycle)

Cycle 1 GMT 9/ 1/2020 10:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 31 15.29 453 215 0.21 / 2.05 6 9
2 3 894.32 -2 15.55 2 0 0.00 / 2.05 6 9
3 7 913.72 41 15.11 1743 1080 1.29 / 3.13 9 73
4 13 163.56 20 15.30 613 188 1.48 / 3.32 6 77
5 13 44.00 20 15.33 390 120 1.60 / 3.44 6 69
6 8 0.04 259 15.28 308 1219 2.82 / 4.65 6 137
Average= 2.33
(KJ/cycle)

Cycle 0 GMT 8/ 1/2020 23:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 98.52 30 15.46 440 204 0.20 / 0.20 6 12
2 7 108.56 40 15.44 451 279 0.48 / 0.48 12 15
3 13 68.20 20 15.43 391 121 0.60 / 0.60 6 20
4 13 37.32 20 15.42 348 107 0.71 / 0.71 6 24
5 8 0.20 263 15.37 278 1124 1.83 / 1.83 6 132
Average= 1.83
(KJ/cycle)