SIO Argo Site:
Pump Diagnostics Page   



Serial= 7501 WMO= 4903218

Return

←PreviousNext→

Cycle 104 GMT 27/11/2021 17:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 30 14.85 435 194 0.19 / 562.50 7 18
2 7 2009.32 41 14.58 3121 1866 2.06 / 564.37 18 60
3 13 1926.52 20 14.55 3015 877 2.94 / 565.24 6 67
4 13 1323.76 20 14.57 2190 638 3.57 / 565.88 6 80
5 13 894.56 20 14.62 1624 475 4.05 / 566.36 6 85
6 13 102.64 20 14.88 477 142 4.19 / 566.50 6 75
7 8 0.16 283 14.85 292 1227 5.42 / 567.73 6 135
Average= 5.41
(KJ/cycle)

Cycle 103 GMT 17/11/2021 20:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 30 14.87 447 199 0.20 / 556.95 7 19
2 7 2008.76 40 14.58 3120 1820 2.02 / 558.77 19 62
3 13 1922.08 20 14.54 3013 876 2.90 / 559.65 6 66
4 13 1496.36 20 14.54 2436 708 3.60 / 560.36 6 76
5 13 1049.12 20 14.58 1828 533 4.14 / 560.89 6 84
6 13 144.40 20 14.85 550 163 4.30 / 561.05 6 77
7 8 0.00 285 14.85 296 1253 5.55 / 562.31 6 129
Average= 5.41
(KJ/cycle)

Cycle 102 GMT 7/11/2021 22:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 30 14.85 438 195 0.20 / 551.46 7 20
2 7 2006.96 40 14.59 3109 1814 2.01 / 553.28 20 60
3 13 1913.16 20 14.56 3016 878 2.89 / 554.15 6 65
4 13 1591.44 20 14.54 2547 741 3.63 / 554.90 6 74
5 13 895.44 20 14.64 1622 475 4.10 / 555.37 6 87
6 13 129.12 20 14.87 525 156 4.26 / 555.53 6 74
7 8 0.00 280 14.86 295 1227 5.49 / 556.75 6 131
Average= 5.41
(KJ/cycle)

Cycle 101 GMT 29/10/2021 1:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 30 14.86 442 197 0.20 / 545.95 7 19
2 7 2006.80 40 14.59 3132 1828 2.02 / 547.77 19 62
3 13 1916.48 20 14.53 3047 885 2.91 / 548.66 6 67
4 13 1594.76 20 14.52 2572 747 3.66 / 549.41 6 74
5 13 909.96 20 14.64 1630 477 4.13 / 549.88 6 86
6 13 136.52 20 14.87 534 159 4.29 / 550.04 6 75
7 8 0.08 283 14.86 291 1224 5.52 / 551.27 6 137
Average= 5.40
(KJ/cycle)

Cycle 100 GMT 19/10/2021 4:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 30 14.86 438 195 0.20 / 540.46 7 19
2 7 2008.84 40 14.59 3149 1838 2.03 / 542.30 19 61
3 13 1911.40 20 14.56 2987 870 2.90 / 543.17 6 66
4 13 1392.60 20 14.57 2297 669 3.57 / 543.84 6 77
5 13 861.60 20 14.64 1581 463 4.04 / 544.30 6 86
6 13 197.96 20 14.84 637 189 4.22 / 544.49 6 80
7 8 -0.04 285 14.85 297 1257 5.48 / 545.75 6 135
Average= 5.40
(KJ/cycle)

Cycle 99 GMT 9/10/2021 7: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 30 14.87 446 199 0.20 / 534.99 7 18
2 7 2004.36 40 14.59 3110 1815 2.01 / 536.81 18 60
3 13 1804.00 20 14.57 2859 833 2.85 / 537.64 6 67
4 13 1618.64 20 14.52 2610 758 3.61 / 538.40 6 73
5 13 818.12 20 14.66 1524 447 4.05 / 538.85 6 87
6 13 160.40 20 14.86 578 172 4.22 / 539.02 6 79
7 8 0.08 282 14.85 299 1252 5.48 / 540.27 6 137
Average= 5.40
(KJ/cycle)

Cycle 98 GMT 29/ 9/2021 9:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 30 14.88 448 200 0.20 / 529.37 7 18
2 7 2015.44 40 14.59 3126 1824 2.02 / 531.20 18 60
3 13 1938.40 20 14.55 3042 885 2.91 / 532.08 6 64
4 13 1620.56 20 14.52 2600 755 3.66 / 532.84 6 73
5 13 1042.24 20 14.59 1814 529 4.19 / 533.37 6 83
6 13 139.24 20 14.87 548 163 4.36 / 533.53 6 76
7 13 27.60 20 14.90 352 105 4.46 / 533.63 6 73
8 8 -0.08 261 14.85 299 1159 5.62 / 534.79 6 131
Average= 5.40
(KJ/cycle)

Cycle 97 GMT 19/ 9/2021 12:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 30 14.88 437 195 0.20 / 523.78 7 18
2 3 1021.20 1 15.03 1896 28 0.22 / 523.81 6 21
3 7 2009.84 40 14.60 3131 1829 2.05 / 525.63 21 59
4 13 1920.72 20 14.55 3031 882 2.93 / 526.52 6 64
5 13 1615.36 20 14.53 2631 765 3.70 / 527.28 6 71
6 13 928.52 20 14.63 1662 486 4.18 / 527.77 6 84
7 13 87.64 20 14.89 466 139 4.32 / 527.91 6 73
8 8 0.08 282 14.87 302 1266 5.59 / 529.17 6 140
Average= 5.40
(KJ/cycle)

Cycle 96 GMT 9/ 9/2021 15:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 30 14.88 453 202 0.20 / 518.24 7 18
2 7 2008.68 41 14.58 3133 1873 2.08 / 520.11 18 61
3 13 1928.00 20 14.56 3008 876 2.95 / 520.99 6 66
4 13 1411.08 20 14.57 2323 677 3.63 / 521.67 6 76
5 13 1081.08 20 14.59 1868 545 4.17 / 522.21 6 83
6 13 69.56 20 14.91 421 126 4.30 / 522.34 6 74
7 8 0.00 282 14.87 297 1245 5.54 / 523.58 6 137
Average= 5.40
(KJ/cycle)

Cycle 95 GMT 30/ 8/2021 18: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 30 14.88 441 197 0.20 / 512.71 7 20
2 7 2008.56 40 14.59 3150 1838 2.04 / 514.55 20 62
3 13 1929.20 20 14.56 3020 879 2.91 / 515.43 6 66
4 13 1396.80 20 14.58 2297 670 3.58 / 516.10 6 79
5 13 955.00 20 14.63 1697 497 4.08 / 516.59 6 85
6 13 176.76 20 14.86 596 177 4.26 / 516.77 6 81
7 8 -0.04 289 14.86 295 1267 5.52 / 518.04 6 135
Average= 5.40
(KJ/cycle)

Cycle 94 GMT 20/ 8/2021 20:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 30 14.88 452 202 0.20 / 507.37 7 21
2 7 2010.00 40 14.60 3112 1817 2.02 / 509.19 21 61
3 13 1723.64 20 14.59 2756 804 2.82 / 509.99 6 70
4 13 1318.72 20 14.59 2211 645 3.47 / 510.64 6 79
5 13 898.16 20 14.64 1613 472 3.94 / 511.11 6 86
6 13 102.44 20 14.89 481 143 4.08 / 511.25 6 77
7 8 -0.04 285 14.87 297 1259 5.34 / 512.51 6 130
Average= 5.39
(KJ/cycle)

Cycle 93 GMT 10/ 8/2021 23:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 30 14.87 446 199 0.20 / 501.96 7 21
2 7 2009.28 41 14.60 3113 1863 2.06 / 503.83 21 61
3 13 1806.36 20 14.59 2854 833 2.90 / 504.66 6 68
4 13 1384.88 20 14.58 2277 664 3.56 / 505.32 6 77
5 13 835.12 20 14.66 1546 453 4.01 / 505.78 6 86
6 13 85.96 20 14.90 461 137 4.15 / 505.91 6 75
7 8 -0.04 280 14.87 302 1257 5.41 / 507.17 6 136
Average= 5.40
(KJ/cycle)

Cycle 92 GMT 1/ 8/2021 2:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 30 14.88 448 200 0.20 / 496.43 7 21
2 7 2006.16 40 14.60 3118 1821 2.02 / 498.25 21 60
3 13 1925.08 20 14.56 3004 875 2.90 / 499.13 6 66
4 13 1510.00 20 14.55 2438 709 3.61 / 499.84 6 76
5 13 969.48 20 14.63 1710 500 4.11 / 500.34 6 85
6 13 183.36 20 14.87 614 183 4.29 / 500.52 6 81
7 8 0.04 282 14.87 297 1245 5.53 / 501.76 6 132
Average= 5.40
(KJ/cycle)

Cycle 91 GMT 22/ 7/2021 4:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 30 14.88 452 202 0.20 / 490.88 7 20
2 7 2014.60 40 14.59 3149 1838 2.04 / 492.72 6 59
3 13 1923.32 20 14.56 3037 884 2.92 / 493.60 6 65
4 13 1395.52 20 14.58 2303 672 3.60 / 494.27 6 76
5 13 864.36 20 14.66 1586 465 4.06 / 494.74 6 84
6 13 210.56 20 14.85 656 195 4.26 / 494.93 6 79
7 8 -0.08 290 14.87 301 1298 5.55 / 496.23 6 138
Average= 5.39
(KJ/cycle)

Cycle 90 GMT 12/ 7/2021 7:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 30 14.88 441 197 0.20 / 485.45 7 21
2 7 2008.08 40 14.61 3121 1824 2.02 / 487.28 21 62
3 13 1815.92 20 14.58 2864 835 2.86 / 488.11 6 69
4 13 1411.64 20 14.58 2319 676 3.53 / 488.79 6 78
5 13 967.88 20 14.63 1731 506 4.04 / 489.29 6 85
6 13 76.76 20 14.91 440 131 4.17 / 489.43 6 71
7 8 0.00 282 14.88 298 1250 5.42 / 490.68 6 131
Average= 5.39
(KJ/cycle)

Cycle 89 GMT 2/ 7/2021 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 30 14.89 445 199 0.20 / 480.04 7 21
2 7 2013.44 40 14.60 3120 1822 2.02 / 481.87 21 59
3 13 1920.20 20 14.58 2983 870 2.89 / 482.74 6 66
4 13 1393.00 20 14.58 2291 668 3.56 / 483.40 6 78
5 13 762.16 20 14.69 1451 426 3.99 / 483.83 6 88
6 13 207.20 20 14.86 650 193 4.18 / 484.02 6 82
7 8 0.08 278 14.87 298 1232 5.41 / 485.26 6 137
Average= 5.39
(KJ/cycle)

Cycle 88 GMT 22/ 6/2021 12:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 30 14.89 450 201 0.20 / 474.65 7 23
2 7 2008.44 41 14.60 3113 1863 2.06 / 476.52 23 59
3 13 1820.64 20 14.58 2888 842 2.91 / 477.36 6 67
4 13 1498.72 20 14.56 2437 710 3.62 / 478.07 6 76
5 13 639.08 20 14.74 1284 379 3.99 / 478.45 6 89
6 13 102.20 20 14.91 483 144 4.14 / 478.59 6 76
7 8 0.08 283 14.89 298 1256 5.39 / 479.85 6 132
Average= 5.39
(KJ/cycle)

Cycle 87 GMT 12/ 6/2021 15:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 30 14.88 447 200 0.20 / 469.19 7 22
2 7 2009.88 41 14.60 3102 1857 2.06 / 471.05 22 61
3 13 1917.36 20 14.57 3002 875 2.93 / 471.92 6 66
4 13 1486.80 20 14.57 2405 701 3.63 / 472.62 6 76
5 13 850.84 20 14.68 1545 454 4.09 / 473.07 6 86
6 13 83.80 20 14.92 455 136 4.22 / 473.21 6 72
7 8 0.12 280 14.88 298 1242 5.46 / 474.45 6 129
Average= 5.39
(KJ/cycle)

Cycle 86 GMT 2/ 6/2021 18:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 30 14.89 448 200 0.20 / 463.47 7 23
2 7 2004.96 40 14.61 3116 1821 2.02 / 465.29 23 60
3 13 1925.80 20 14.58 3019 880 2.90 / 466.17 6 63
4 13 1511.00 20 14.56 2485 724 3.63 / 466.90 6 75
5 13 1176.68 20 14.58 2013 587 4.21 / 467.48 6 83
6 13 233.88 20 14.86 699 208 4.42 / 467.69 6 82
7 8 0.04 289 14.88 302 1299 5.72 / 468.99 6 140
Average= 5.39
(KJ/cycle)

Cycle 85 GMT 23/ 5/2021 21:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 30 14.88 461 206 0.21 / 458.02 7 22
2 7 2011.36 40 14.61 3137 1833 2.04 / 459.85 22 60
3 13 1930.32 20 14.56 3036 884 2.92 / 460.74 6 64
4 13 1414.44 20 14.58 2340 682 3.61 / 461.42 6 77
5 13 752.68 20 14.70 1436 422 4.03 / 461.84 6 88
6 13 95.88 20 14.91 475 142 4.17 / 461.99 6 73
7 8 0.16 285 14.88 303 1285 5.45 / 463.27 6 142
Average= 5.39
(KJ/cycle)

Cycle 84 GMT 14/ 5/2021 0:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 30 14.89 460 205 0.21 / 452.47 7 23
2 7 2011.72 40 14.61 3121 1824 2.03 / 454.30 23 59
3 13 1920.16 20 14.59 2990 872 2.90 / 455.17 6 64
4 13 1382.00 20 14.59 2279 665 3.57 / 455.84 6 77
5 13 943.28 20 14.66 1682 493 4.06 / 456.33 6 84
6 13 265.24 20 14.85 738 219 4.28 / 456.55 6 82
7 8 0.16 287 14.88 297 1268 5.55 / 457.82 6 129
Average= 5.39
(KJ/cycle)

Cycle 83 GMT 4/ 5/2021 3: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 30 14.90 455 203 0.20 / 446.90 7 24
2 7 2011.36 40 14.61 3114 1820 2.02 / 448.72 24 60
3 13 1931.48 20 14.58 3013 879 2.90 / 449.60 6 64
4 13 1509.44 20 14.57 2451 714 3.62 / 450.32 6 75
5 13 947.36 20 14.65 1685 494 4.11 / 450.81 6 84
6 13 166.04 20 14.89 593 177 4.29 / 450.99 6 78
7 8 0.00 287 14.89 300 1282 5.57 / 452.27 6 129
Average= 5.38
(KJ/cycle)

Cycle 82 GMT 24/ 4/2021 5:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 30 14.89 459 205 0.21 / 441.47 7 24
2 7 2012.72 40 14.62 3105 1816 2.02 / 443.29 24 59
3 13 1921.20 20 14.58 2992 872 2.89 / 444.16 6 65
4 13 1387.76 20 14.60 2276 665 3.56 / 444.82 6 77
5 13 953.40 20 14.66 1697 498 4.06 / 445.32 6 86
6 13 84.68 20 14.93 455 136 4.19 / 445.46 6 70
7 8 0.04 280 14.90 298 1243 5.43 / 446.70 6 138
Average= 5.38
(KJ/cycle)

Cycle 81 GMT 14/ 4/2021 8:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 30 14.91 429 192 0.19 / 435.93 7 25
2 7 2005.44 41 14.61 3122 1870 2.06 / 437.80 25 61
3 13 1912.04 20 14.59 3005 877 2.94 / 438.68 6 64
4 13 1384.80 20 14.60 2299 671 3.61 / 439.35 6 76
5 13 952.08 20 14.66 1691 496 4.11 / 439.84 6 85
6 13 140.84 20 14.91 539 161 4.27 / 440.00 6 76
7 8 0.16 287 14.90 295 1262 5.53 / 441.27 6 131
Average= 5.38
(KJ/cycle)

Cycle 80 GMT 4/ 4/2021 11: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 30 14.89 439 196 0.20 / 430.37 7 25
2 7 2012.20 41 14.61 3127 1873 2.07 / 432.24 25 60
3 13 1926.44 20 14.57 3040 886 2.96 / 433.13 6 65
4 13 1494.80 20 14.58 2448 714 3.67 / 433.84 6 75
5 13 829.28 20 14.69 1549 455 4.12 / 434.30 6 86
6 13 154.64 20 14.91 572 171 4.29 / 434.47 6 75
7 8 0.08 287 14.90 297 1270 5.56 / 435.74 6 131
Average= 5.38
(KJ/cycle)

Cycle 79 GMT 25/ 3/2021 13:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 30 14.91 439 196 0.20 / 424.81 7 25
2 7 2012.88 41 14.62 3131 1877 2.07 / 426.69 6 60
3 13 1942.08 20 14.57 3053 890 2.96 / 427.58 6 64
4 13 1417.84 20 14.58 2348 685 3.65 / 428.27 6 76
5 13 775.12 20 14.71 1464 431 4.08 / 428.70 6 88
6 13 214.16 20 14.88 665 198 4.28 / 428.89 6 79
7 8 0.16 287 14.90 299 1279 5.55 / 430.17 6 138
Average= 5.38
(KJ/cycle)

Cycle 78 GMT 15/ 3/2021 16:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 30 14.88 455 203 0.20 / 419.43 7 26
2 7 2007.00 40 14.63 3101 1815 2.02 / 421.24 26 58
3 13 1923.24 20 14.59 3012 879 2.90 / 422.12 6 65
4 13 1317.00 20 14.61 2194 641 3.54 / 422.76 6 78
5 13 688.68 20 14.75 1349 398 3.94 / 423.16 6 88
6 13 138.76 20 14.92 537 160 4.10 / 423.32 6 75
7 8 0.00 289 14.91 301 1297 5.39 / 424.62 6 140
Average= 5.37
(KJ/cycle)

Cycle 77 GMT 5/ 3/2021 19:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 30 14.91 444 199 0.20 / 413.54 7 24
2 7 2005.04 41 14.62 3129 1876 2.07 / 415.41 24 59
3 13 1825.80 20 14.60 2873 839 2.91 / 416.25 6 68
4 13 1732.80 20 14.53 2764 803 3.72 / 417.06 6 70
5 13 888.12 20 14.69 1610 473 4.19 / 417.53 6 85
6 13 636.20 20 14.74 1255 370 4.56 / 417.90 6 91
7 8 -0.04 289 14.89 308 1325 5.88 / 419.22 6 133
Average= 5.37
(KJ/cycle)

Cycle 76 GMT 23/ 2/2021 22:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 30 14.91 462 207 0.21 / 408.01 7 24
2 7 2015.48 40 14.62 3150 1842 2.05 / 409.86 24 61
3 13 1930.88 20 14.60 3026 884 2.93 / 410.74 6 64
4 13 1382.32 20 14.61 2291 669 3.60 / 411.41 6 77
5 13 858.68 20 14.69 1575 463 4.06 / 411.87 6 86
6 13 187.20 20 14.90 621 185 4.25 / 412.06 6 79
7 8 0.04 287 14.91 300 1284 5.53 / 413.34 6 134
Average= 5.37
(KJ/cycle)

Cycle 75 GMT 14/ 2/2021 1:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 30 14.91 450 201 0.20 / 402.54 7 24
2 7 2007.60 40 14.63 3133 1833 2.03 / 404.38 24 61
3 13 1921.28 20 14.59 2999 875 2.91 / 405.25 6 65
4 13 1312.12 20 14.63 2201 644 3.55 / 405.90 6 80
5 13 874.56 20 14.69 1591 467 4.02 / 406.36 6 86
6 13 105.52 20 14.94 492 147 4.17 / 406.51 6 73
7 8 0.12 287 14.91 303 1297 5.46 / 407.81 6 140
Average= 5.37
(KJ/cycle)

Cycle 74 GMT 4/ 2/2021 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 30 14.92 464 208 0.21 / 397.13 7 24
2 7 2003.88 40 14.62 3119 1824 2.03 / 398.95 24 61
3 13 1907.52 20 14.58 3025 882 2.91 / 399.83 6 65
4 13 1379.24 20 14.61 2299 672 3.59 / 400.50 6 78
5 13 732.76 20 14.73 1431 422 4.01 / 400.93 6 89
6 13 79.56 20 14.95 456 136 4.14 / 401.06 6 74
7 8 0.16 276 14.91 311 1280 5.42 / 402.34 6 130
Average= 5.36
(KJ/cycle)

Cycle 73 GMT 25/ 1/2021 6:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 30 14.91 465 208 0.21 / 391.61 7 23
2 7 2006.40 40 14.62 3142 1837 2.05 / 393.45 23 61
3 13 1916.04 20 14.60 3017 881 2.93 / 394.33 6 67
4 13 1381.52 20 14.62 2286 668 3.59 / 395.00 6 79
5 13 868.28 20 14.70 1587 467 4.06 / 395.46 6 86
6 13 108.52 20 14.95 501 150 4.21 / 395.61 6 74
7 8 -0.04 285 14.92 307 1305 5.52 / 396.92 6 133
Average= 5.36
(KJ/cycle)

Cycle 72 GMT 15/ 1/2021 9: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 30 14.92 461 206 0.21 / 386.12 7 21
2 7 2006.24 40 14.62 3129 1830 2.04 / 387.95 21 60
3 13 1910.04 20 14.61 2978 870 2.91 / 388.82 6 66
4 13 1466.44 20 14.61 2405 703 3.61 / 389.52 6 77
5 13 796.80 20 14.73 1486 438 4.05 / 389.96 6 87
6 13 119.88 20 14.94 515 154 4.20 / 390.11 6 76
7 8 0.08 285 14.92 303 1288 5.49 / 391.40 6 130
Average= 5.36
(KJ/cycle)

Cycle 71 GMT 5/ 1/2021 11:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 30 14.92 460 206 0.21 / 380.55 7 21
2 7 2009.12 40 14.63 3141 1838 2.04 / 382.39 6 60
3 13 1918.80 20 14.59 3041 887 2.93 / 383.28 6 66
4 13 1370.08 20 14.62 2273 665 3.60 / 383.94 6 79
5 13 837.24 20 14.72 1552 457 4.05 / 384.40 6 86
6 13 252.04 20 14.89 734 219 4.27 / 384.62 6 84
7 8 0.12 285 14.92 305 1297 5.57 / 385.91 6 129
Average= 5.36
(KJ/cycle)

Cycle 70 GMT 26/12/2020 14:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 30 14.94 451 202 0.20 / 374.95 7 18
2 7 2007.88 40 14.63 3143 1839 2.04 / 376.79 18 60
3 13 1909.88 20 14.59 3028 884 2.92 / 377.67 6 66
4 13 1385.92 20 14.62 2304 674 3.60 / 378.35 6 77
5 13 749.36 20 14.75 1445 426 4.02 / 378.77 6 86
6 13 323.60 20 14.87 835 248 4.27 / 379.02 6 83
7 8 -0.12 289 14.92 307 1324 5.60 / 380.34 6 132
Average= 5.36
(KJ/cycle)

Cycle 69 GMT 16/12/2020 17:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 30 14.94 445 199 0.20 / 369.54 7 19
2 7 2003.20 41 14.65 3079 1849 2.05 / 371.39 19 60
3 13 1904.40 20 14.61 3010 880 2.93 / 372.27 6 67
4 13 1375.12 20 14.64 2272 665 3.59 / 372.93 6 78
5 13 730.32 20 14.76 1404 414 4.01 / 373.35 6 88
6 13 94.36 20 14.96 470 141 4.15 / 373.49 6 73
7 8 0.08 282 14.94 299 1260 5.41 / 374.75 6 137
Average= 5.35
(KJ/cycle)

Cycle 68 GMT 6/12/2020 20: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 30 14.96 449 202 0.20 / 363.97 7 18
2 7 2009.56 40 14.66 3116 1827 2.03 / 365.80 18 59
3 13 1918.96 20 14.62 2999 877 2.91 / 366.68 6 64
4 13 1572.56 20 14.60 2539 741 3.65 / 367.42 6 72
5 13 796.36 20 14.75 1493 440 4.09 / 367.86 6 86
6 13 144.64 20 14.95 561 168 4.26 / 368.03 6 78
7 8 0.00 291 14.94 302 1313 5.57 / 369.34 6 144
Average= 5.35
(KJ/cycle)

Cycle 67 GMT 26/11/2020 22:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 30 14.96 456 205 0.20 / 358.61 7 16
2 7 2008.16 40 14.64 3128 1832 2.04 / 360.44 16 60
3 13 1909.32 20 14.60 3041 888 2.92 / 361.33 6 66
4 13 1361.84 20 14.64 2286 669 3.59 / 362.00 6 77
5 13 721.88 20 14.77 1395 412 4.01 / 362.41 6 88
6 13 91.20 20 14.97 466 140 4.15 / 362.55 6 73
7 8 0.16 267 14.95 306 1221 5.37 / 363.77 6 133
Average= 5.35
(KJ/cycle)

Cycle 66 GMT 17/11/2020 1:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 30 14.95 451 202 0.20 / 353.36 7 18
2 7 2007.20 40 14.65 3115 1825 2.03 / 355.19 18 60
3 13 1721.16 20 14.65 2719 797 2.82 / 355.98 6 70
4 13 1301.92 20 14.66 2164 634 3.46 / 356.62 6 80
5 13 677.72 20 14.79 1335 395 3.85 / 357.01 6 88
6 13 67.28 20 14.99 428 128 3.98 / 357.14 6 71
7 8 0.04 278 14.95 304 1263 5.25 / 358.40 6 129
Average= 5.35
(KJ/cycle)

Cycle 65 GMT 7/11/2020 4: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 30 14.97 448 201 0.20 / 347.74 7 16
2 7 2006.28 40 14.64 3156 1848 2.05 / 349.59 16 60
3 13 1912.36 20 14.62 3014 881 2.93 / 350.47 6 67
4 13 1474.20 20 14.63 2433 712 3.64 / 351.18 6 76
5 13 1006.00 20 14.70 1770 520 4.16 / 351.70 6 85
6 13 118.64 20 14.98 521 156 4.32 / 351.85 6 76
7 8 -0.12 285 14.95 306 1304 5.62 / 353.16 6 138
Average= 5.35
(KJ/cycle)

Cycle 64 GMT 28/10/2020 6:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 30 14.97 446 200 0.20 / 342.39 7 16
2 7 2003.32 40 14.66 3107 1822 2.02 / 344.21 16 59
3 13 1815.32 20 14.64 2848 834 2.86 / 345.05 6 67
4 13 1297.24 20 14.67 2183 640 3.50 / 345.69 6 80
5 13 674.84 20 14.79 1347 398 3.90 / 346.09 6 88
6 13 114.60 20 14.98 513 154 4.05 / 346.24 6 77
7 8 -0.04 285 14.96 304 1296 5.34 / 347.54 6 135
Average= 5.35
(KJ/cycle)

Cycle 63 GMT 18/10/2020 9:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 30 14.99 446 201 0.20 / 337.07 7 16
2 7 2007.84 40 14.66 3132 1837 2.04 / 338.91 16 61
3 13 1913.36 20 14.63 3003 879 2.92 / 339.79 6 66
4 13 1267.84 20 14.68 2127 624 3.54 / 340.41 6 80
5 13 643.76 20 14.82 1282 380 3.92 / 340.79 6 88
6 13 51.64 20 15.02 406 122 4.04 / 340.92 6 71
7 8 0.00 280 14.97 304 1274 5.32 / 342.19 6 134
Average= 5.35
(KJ/cycle)

Cycle 62 GMT 8/10/2020 12: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 30 14.99 454 204 0.20 / 331.58 7 16
2 7 2008.72 40 14.67 3121 1831 2.04 / 333.41 16 58
3 13 1728.12 20 14.66 2769 812 2.85 / 334.22 6 70
4 13 1635.36 20 14.60 2627 767 3.61 / 334.99 6 72
5 13 756.84 20 14.79 1441 426 4.04 / 335.41 6 88
6 13 102.48 20 15.01 491 147 4.19 / 335.56 6 76
7 8 0.04 287 14.99 305 1312 5.50 / 336.87 6 133
Average= 5.35
(KJ/cycle)

Cycle 61 GMT 28/ 9/2020 14:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 30 14.98 448 201 0.20 / 326.20 7 17
2 7 2005.84 40 14.66 3121 1830 2.03 / 328.03 17 59
3 13 1822.44 20 14.65 2894 848 2.88 / 328.88 6 67
4 13 1305.12 20 14.69 2185 642 3.52 / 329.52 6 79
5 13 757.64 20 14.79 1441 426 3.95 / 329.95 6 89
6 13 55.16 20 15.02 416 125 4.07 / 330.07 6 72
7 8 0.00 281 14.98 309 1301 5.37 / 331.37 6 137
Average= 5.34
(KJ/cycle)

Cycle 60 GMT 18/ 9/2020 17:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 29 14.99 440 191 0.19 / 320.78 7 18
2 7 2004.48 40 14.66 3131 1836 2.03 / 322.62 18 60
3 13 1921.00 20 14.63 3041 890 2.92 / 323.51 6 66
4 13 1386.56 20 14.67 2281 669 3.59 / 324.17 6 77
5 13 722.20 20 14.81 1403 416 4.00 / 324.59 6 90
6 13 79.08 20 15.02 451 135 4.14 / 324.73 6 75
7 8 0.12 278 14.99 306 1275 5.41 / 326.00 6 136
Average= 5.34
(KJ/cycle)

Cycle 59 GMT 8/ 9/2020 20: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 29 15.00 446 194 0.19 / 315.38 7 16
2 7 2004.80 40 14.67 3101 1820 2.01 / 317.20 16 60
3 13 1907.08 20 14.64 2972 870 2.88 / 318.07 6 66
4 13 1369.16 20 14.68 2262 664 3.55 / 318.73 6 78
5 13 707.96 20 14.82 1378 408 3.96 / 319.14 6 88
6 13 147.40 20 15.00 563 169 4.13 / 319.31 6 78
7 8 0.04 285 14.99 299 1277 5.40 / 320.59 6 135
Average= 5.34
(KJ/cycle)

Cycle 58 GMT 29/ 8/2020 22:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 29 15.00 450 196 0.20 / 309.86 7 18
2 7 2008.36 40 14.68 3093 1816 2.01 / 311.68 18 59
3 13 1922.12 20 14.63 3014 882 2.89 / 312.56 6 65
4 13 1380.84 20 14.68 2278 669 3.56 / 313.23 6 75
5 13 871.04 20 14.78 1583 468 4.03 / 313.69 6 85
6 13 183.76 20 14.99 624 187 4.22 / 313.88 6 80
7 8 -0.04 287 14.99 303 1304 5.52 / 315.19 6 130
Average= 5.34
(KJ/cycle)

Cycle 57 GMT 20/ 8/2020 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 30 15.02 448 202 0.20 / 304.36 7 17
2 7 2012.96 40 14.68 3103 1822 2.02 / 306.18 17 59
3 13 1924.68 20 14.65 2996 878 2.90 / 307.06 6 64
4 13 1396.36 20 14.68 2296 674 3.58 / 307.74 6 76
5 13 862.04 20 14.78 1571 464 4.04 / 308.20 6 85
6 13 181.12 20 15.00 616 185 4.23 / 308.39 6 79
7 8 -0.04 285 15.00 299 1278 5.50 / 309.66 6 136
Average= 5.34
(KJ/cycle)

Cycle 56 GMT 10/ 8/2020 4:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 30 15.02 457 206 0.21 / 298.98 7 19
2 7 2020.52 40 14.68 3133 1840 2.05 / 300.82 19 60
3 13 1940.44 20 14.63 3046 891 2.94 / 301.71 6 66
4 13 1314.00 20 14.70 2198 646 3.58 / 302.36 6 79
5 13 765.84 20 14.81 1450 429 4.01 / 302.79 6 87
6 13 56.88 20 15.05 408 123 4.14 / 302.91 6 70
7 8 0.12 274 15.01 304 1250 5.39 / 304.16 6 129
Average= 5.34
(KJ/cycle)

Cycle 55 GMT 31/ 7/2020 6:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 30 15.02 458 206 0.21 / 293.47 7 19
2 7 2016.36 41 14.68 3120 1878 2.08 / 295.35 19 59
3 13 1931.44 20 14.64 3039 890 2.97 / 296.24 6 64
4 13 1374.76 20 14.68 2279 669 3.64 / 296.91 6 76
5 13 820.60 20 14.80 1526 452 4.09 / 297.36 6 87
6 13 89.00 20 15.05 460 138 4.23 / 297.50 6 71
7 8 0.00 283 15.02 301 1279 5.51 / 298.78 6 134
Average= 5.34
(KJ/cycle)

Cycle 54 GMT 21/ 7/2020 9: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 29 15.04 460 201 0.20 / 287.77 7 18
2 7 2007.80 40 14.69 3111 1828 2.03 / 289.59 18 59
3 13 1913.52 20 14.66 3016 884 2.91 / 290.48 6 65
4 13 1465.12 20 14.68 2412 708 3.62 / 291.19 6 76
5 13 1272.04 20 14.68 2129 625 4.25 / 291.81 6 80
6 13 104.68 20 15.05 494 149 4.39 / 291.96 6 73
7 8 0.04 285 15.02 304 1301 5.70 / 293.26 6 134
Average= 5.33
(KJ/cycle)

Cycle 53 GMT 11/ 7/2020 11:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 30 15.03 455 205 0.21 / 282.25 7 19
2 7 2008.80 40 14.69 3098 1820 2.03 / 284.07 19 59
3 13 1924.80 20 14.66 3015 884 2.91 / 284.95 6 65
4 13 1399.32 20 14.69 2327 684 3.59 / 285.64 6 77
5 13 961.12 20 14.77 1711 505 4.10 / 286.14 6 83
6 13 74.68 20 15.07 440 133 4.23 / 286.27 6 69
7 8 0.00 280 15.03 307 1292 5.52 / 287.57 6 137
Average= 5.33
(KJ/cycle)

Cycle 52 GMT 1/ 7/2020 14:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 30 15.04 461 208 0.21 / 276.85 7 19
2 7 2009.88 40 14.68 3116 1830 2.04 / 278.68 19 60
3 13 1921.00 20 14.66 3016 884 2.92 / 279.56 6 64
4 13 1221.52 20 14.73 2084 614 3.54 / 280.18 6 79
5 13 705.60 20 14.86 1388 413 3.95 / 280.59 6 88
6 13 154.72 20 15.04 580 174 4.12 / 280.76 6 77
7 8 0.00 280 15.03 304 1279 5.40 / 282.04 6 139
Average= 5.32
(KJ/cycle)

Cycle 51 GMT 21/ 6/2020 16:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 30 15.04 452 204 0.20 / 271.45 7 18
2 7 2006.96 40 14.70 3114 1831 2.03 / 273.28 18 60
3 13 1912.64 20 14.66 3029 888 2.92 / 274.17 6 65
4 13 1454.36 20 14.69 2378 699 3.62 / 274.87 6 76
5 13 590.52 20 14.91 1223 365 3.99 / 275.24 6 88
6 13 37.32 20 15.09 377 114 4.10 / 275.35 6 68
7 8 0.12 278 15.04 309 1292 5.39 / 276.64 6 133
Average= 5.32
(KJ/cycle)

Cycle 50 GMT 11/ 6/2020 19:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 29 15.04 456 199 0.20 / 265.74 7 20
2 7 2006.84 40 14.69 3132 1840 2.04 / 267.58 6 58
3 13 1916.44 20 14.66 3006 881 2.92 / 268.46 6 64
4 13 1289.08 20 14.74 2169 639 3.56 / 269.10 6 78
5 13 1205.88 20 14.70 2046 602 4.16 / 269.70 6 81
6 13 257.08 20 15.01 744 223 4.38 / 269.92 6 82
7 8 0.00 285 15.04 309 1324 5.71 / 271.25 6 137
Average= 5.32
(KJ/cycle)

Cycle 49 GMT 1/ 6/2020 22:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 29 15.06 464 203 0.20 / 260.00 7 19
2 7 2005.40 40 14.71 3102 1825 2.03 / 261.83 19 58
3 13 1921.76 20 14.67 3039 892 2.92 / 262.72 6 64
4 13 1468.80 20 14.70 2409 708 3.63 / 263.43 6 75
5 13 904.20 20 14.82 1626 482 4.11 / 263.91 6 84
6 13 430.24 20 14.95 984 294 4.40 / 264.21 6 87
7 8 -0.04 287 15.04 309 1334 5.74 / 265.54 6 131
Average= 5.31
(KJ/cycle)

Cycle 48 GMT 23/ 5/2020 1:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 29 15.05 449 196 0.20 / 254.52 7 20
2 7 2013.60 40 14.69 3112 1829 2.02 / 256.34 20 58
3 13 1922.32 20 14.67 3004 881 2.91 / 257.23 6 64
4 13 1381.36 20 14.73 2273 670 3.58 / 257.90 6 75
5 13 930.56 20 14.81 1663 493 4.07 / 258.39 6 84
6 13 38.88 20 15.11 379 115 4.18 / 258.50 6 67
7 8 0.08 280 15.06 308 1299 5.48 / 259.80 6 129
Average= 5.30
(KJ/cycle)

Cycle 47 GMT 13/ 5/2020 3:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 29 15.06 454 198 0.20 / 248.89 7 20
2 7 2006.68 40 14.71 3121 1836 2.03 / 250.73 20 59
3 13 1916.36 20 14.68 3014 885 2.92 / 251.61 6 64
4 13 1196.72 20 14.78 2043 604 3.52 / 252.22 6 79
5 13 1107.24 20 14.76 1902 561 4.08 / 252.78 6 82
6 13 266.76 20 15.02 754 227 4.31 / 253.00 6 83
7 8 0.00 285 15.05 307 1317 5.63 / 254.32 6 132
Average= 5.30
(KJ/cycle)

Cycle 46 GMT 3/ 5/2020 6:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 29 15.06 455 199 0.20 / 243.28 7 21
2 7 2006.24 40 14.69 3145 1848 2.05 / 245.13 6 59
3 13 1912.92 20 14.67 3005 882 2.93 / 246.01 6 64
4 13 1460.48 20 14.71 2396 705 3.63 / 246.72 6 75
5 13 912.12 20 14.83 1650 489 4.12 / 247.21 6 85
6 13 95.48 20 15.09 488 147 4.27 / 247.35 6 75
7 8 0.16 283 15.06 314 1338 5.61 / 248.69 6 130
Average= 5.29
(KJ/cycle)

Cycle 45 GMT 23/ 4/2020 9:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 29 15.07 449 196 0.20 / 237.80 7 21
2 7 2005.32 40 14.72 3115 1834 2.03 / 239.64 21 58
3 13 1812.40 20 14.70 2857 840 2.87 / 240.48 6 66
4 13 1388.84 20 14.73 2293 676 3.55 / 241.15 6 77
5 13 855.00 20 14.86 1560 464 4.01 / 241.62 6 85
6 13 78.20 20 15.10 459 139 4.15 / 241.76 6 73
7 8 0.04 287 15.07 307 1328 5.48 / 243.08 6 136
Average= 5.28
(KJ/cycle)

Cycle 44 GMT 13/ 4/2020 12:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 29 15.08 453 198 0.20 / 232.29 7 21
2 7 2006.44 40 14.71 3130 1842 2.04 / 234.14 21 60
3 13 1917.92 20 14.69 3004 883 2.92 / 235.02 6 65
4 13 1364.44 20 14.75 2245 662 3.58 / 235.68 6 78
5 13 824.04 20 14.87 1515 451 4.04 / 236.13 6 86
6 13 154.00 20 15.08 567 171 4.21 / 236.30 6 78
7 8 0.08 285 15.07 304 1306 5.51 / 237.61 6 131
Average= 5.28
(KJ/cycle)

Cycle 43 GMT 3/ 4/2020 15: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 29 15.08 458 200 0.20 / 226.80 7 23
2 7 2004.88 40 14.72 3112 1832 2.03 / 228.64 23 59
3 13 1820.92 20 14.70 2904 854 2.89 / 229.49 6 68
4 13 1396.80 20 14.74 2315 682 3.57 / 230.17 6 77
5 13 831.92 20 14.87 1534 456 4.03 / 230.63 6 86
6 13 163.56 20 15.08 594 179 4.20 / 230.81 6 78
7 8 -0.04 282 15.08 303 1289 5.49 / 232.10 6 132
Average= 5.27
(KJ/cycle)

Cycle 42 GMT 24/ 3/2020 17:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 29 15.07 462 202 0.20 / 221.27 7 22
2 7 2019.44 40 14.71 3132 1843 2.04 / 223.11 22 59
3 13 1941.48 20 14.69 3032 891 2.94 / 224.00 6 63
4 13 1197.28 20 14.80 2045 605 3.54 / 224.61 6 80
5 13 997.04 20 14.82 1764 523 4.06 / 225.13 6 83
6 13 89.60 20 15.12 469 142 4.21 / 225.27 6 72
7 8 0.00 287 15.08 307 1329 5.53 / 226.60 6 133
Average= 5.27
(KJ/cycle)

Cycle 41 GMT 14/ 3/2020 20:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 29 15.09 458 200 0.20 / 215.60 7 23
2 7 2017.12 41 14.70 3130 1886 2.09 / 217.49 23 59
3 13 1927.24 20 14.68 3040 893 2.98 / 218.38 6 64
4 13 1368.96 20 14.74 2283 673 3.65 / 219.05 6 77
5 13 814.32 20 14.88 1520 452 4.10 / 219.51 6 87
6 13 352.68 20 15.02 867 260 4.37 / 219.77 6 85
7 8 0.00 287 15.08 301 1303 5.67 / 221.07 6 139
Average= 5.26
(KJ/cycle)

Cycle 40 GMT 4/ 3/2020 23:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 29 15.09 457 200 0.20 / 209.87 7 23
2 7 2012.12 40 14.71 3137 1846 2.05 / 211.71 6 59
3 13 1941.28 20 14.67 3087 906 2.95 / 212.62 6 64
4 13 1848.00 20 14.62 2934 858 3.81 / 213.48 6 68
5 13 970.36 20 14.84 1717 510 4.32 / 213.99 6 85
6 13 38.84 20 15.15 383 116 4.44 / 214.10 6 68
7 8 0.08 282 15.10 305 1299 5.73 / 215.40 6 142
Average= 5.25
(KJ/cycle)

Cycle 39 GMT 24/ 2/2020 2:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 29 15.10 452 198 0.20 / 204.42 7 21
2 7 2010.88 40 14.72 3110 1831 2.03 / 206.25 21 59
3 13 1819.44 20 14.72 2879 848 2.88 / 207.10 6 67
4 13 1288.32 20 14.79 2166 641 3.52 / 207.74 6 78
5 13 849.68 20 14.88 1567 466 3.98 / 208.21 6 85
6 13 159.56 20 15.10 583 176 4.16 / 208.38 6 78
7 8 0.04 282 15.09 302 1285 5.44 / 209.67 6 129
Average= 5.24
(KJ/cycle)

Cycle 38 GMT 14/ 2/2020 4:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 29 15.09 466 204 0.20 / 199.13 7 22
2 7 2008.08 40 14.73 3108 1831 2.04 / 200.96 22 58
3 13 1811.00 20 14.71 2885 849 2.88 / 201.81 6 66
4 13 1298.44 20 14.79 2158 638 3.52 / 202.45 6 78
5 13 642.36 20 14.96 1286 385 3.91 / 202.83 6 87
6 8 0.08 302 15.11 304 1387 5.29 / 204.22 6 131
Average= 5.24
(KJ/cycle)

Cycle 37 GMT 4/ 2/2020 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 29 15.11 444 195 0.19 / 193.62 7 22
2 7 2011.16 40 14.74 3113 1835 2.03 / 195.46 22 58
3 13 1922.08 20 14.71 3010 886 2.92 / 196.34 6 63
4 13 1570.68 20 14.72 2531 745 3.66 / 197.09 6 72
5 13 673.44 20 14.95 1338 400 4.06 / 197.49 6 88
6 13 117.60 20 15.13 510 154 4.22 / 197.64 6 75
7 8 0.08 282 15.11 302 1287 5.50 / 198.93 6 136
Average= 5.23
(KJ/cycle)

Cycle 36 GMT 25/ 1/2020 10:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 29 15.11 451 198 0.20 / 188.21 7 22
2 7 2008.00 41 14.73 3121 1885 2.08 / 190.10 22 60
3 13 1916.92 20 14.72 3009 886 2.97 / 190.98 6 64
4 13 1258.20 20 14.82 2108 625 3.59 / 191.61 6 80
5 13 722.28 20 14.94 1398 418 4.01 / 192.03 6 89
6 13 33.64 20 15.16 375 114 4.12 / 192.14 6 70
7 8 0.08 278 15.12 306 1286 5.41 / 193.43 6 135
Average= 5.23
(KJ/cycle)

Cycle 35 GMT 15/ 1/2020 13:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 29 15.12 459 201 0.20 / 182.68 7 20
2 7 2015.72 41 14.73 3126 1888 2.09 / 184.57 20 58
3 13 1927.28 20 14.71 3005 884 2.97 / 185.46 6 64
4 13 1380.64 20 14.77 2294 678 3.65 / 186.13 6 77
5 13 716.72 20 14.94 1385 414 4.06 / 186.55 6 87
6 13 142.60 20 15.12 555 168 4.23 / 186.71 6 79
7 8 0.08 285 15.11 302 1301 5.53 / 188.02 6 140
Average= 5.22
(KJ/cycle)

Cycle 34 GMT 5/ 1/2020 16: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 29 15.12 454 199 0.20 / 177.30 7 20
2 7 2008.88 41 14.73 3110 1878 2.08 / 179.18 20 60
3 13 1919.00 20 14.72 2982 878 2.96 / 180.06 6 65
4 13 1164.40 20 14.85 1991 591 3.55 / 180.65 6 81
5 13 754.56 20 14.93 1441 430 3.98 / 181.08 6 88
6 13 48.24 20 15.17 393 119 4.10 / 181.20 6 70
7 8 0.08 279 15.12 304 1282 5.38 / 182.48 6 139
Average= 5.21
(KJ/cycle)

Cycle 33 GMT 26/12/2019 18:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 29 15.13 447 196 0.20 / 171.85 7 18
2 7 2004.64 40 14.74 3127 1844 2.04 / 173.69 18 59
3 13 1906.12 20 14.71 3015 887 2.93 / 174.58 6 64
4 13 1269.76 20 14.82 2144 635 3.56 / 175.21 6 79
5 13 731.88 20 14.94 1404 420 3.98 / 175.63 6 88
6 13 80.00 20 15.16 460 139 4.12 / 175.77 6 73
7 8 0.04 285 15.12 309 1332 5.45 / 177.10 6 132
Average= 5.21
(KJ/cycle)

Cycle 32 GMT 16/12/2019 21:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 29 15.12 472 207 0.21 / 166.38 7 18
2 3 1019.20 1 15.19 1866 28 0.24 / 166.41 6 11
3 7 2010.04 40 14.74 3139 1851 2.09 / 168.26 11 59
4 13 1715.56 20 14.76 2735 807 2.89 / 169.07 6 69
5 13 1519.80 20 14.74 2469 728 3.62 / 169.79 6 74
6 13 696.96 20 14.95 1386 414 4.04 / 170.21 6 88
7 13 61.60 20 15.17 424 129 4.16 / 170.34 6 71
8 8 0.08 281 15.13 309 1314 5.48 / 171.65 6 131
Average= 5.20
(KJ/cycle)

Cycle 31 GMT 6/12/2019 23:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 29 15.13 452 198 0.20 / 160.59 7 17
2 7 2011.76 40 14.74 3143 1853 2.05 / 162.44 6 60
3 13 1919.28 20 14.72 3030 892 2.94 / 163.33 6 65
4 13 1721.52 20 14.70 2739 805 3.75 / 164.14 6 71
5 13 875.16 20 14.91 1601 477 4.23 / 164.61 6 85
6 13 282.52 20 15.09 779 235 4.46 / 164.85 6 83
7 8 0.00 285 15.13 307 1324 5.79 / 166.17 6 130
Average= 5.19
(KJ/cycle)

Cycle 30 GMT 27/11/2019 2:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 29 15.13 444 195 0.19 / 155.15 7 17
2 7 2005.88 40 14.75 3127 1845 2.04 / 156.99 17 60
3 13 1815.72 20 14.74 2869 846 2.89 / 157.84 6 67
4 13 1383.88 20 14.80 2281 675 3.56 / 158.51 6 77
5 13 712.12 20 14.97 1371 410 3.97 / 158.93 6 88
6 13 74.12 20 15.17 446 135 4.11 / 159.06 6 73
7 8 -0.04 282 15.13 311 1327 5.43 / 160.39 6 134
Average= 5.17
(KJ/cycle)

Cycle 29 GMT 17/11/2019 5:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 29 15.14 449 197 0.20 / 149.78 7 16
2 7 2003.32 40 14.76 3113 1838 2.04 / 151.61 16 59
3 13 1807.64 20 14.76 2860 844 2.88 / 152.46 6 67
4 13 1275.72 20 14.84 2139 635 3.51 / 153.09 6 80
5 13 741.28 20 14.96 1417 424 3.94 / 153.52 6 88
6 13 82.04 20 15.17 457 139 4.08 / 153.66 6 74
7 8 0.08 282 15.14 304 1298 5.37 / 154.95 6 148
Average= 5.17
(KJ/cycle)

Cycle 28 GMT 7/11/2019 8:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 29 15.15 453 199 0.20 / 144.30 7 15
2 7 2004.40 40 14.76 3118 1841 2.04 / 146.14 15 59
3 13 1917.28 20 14.72 3041 895 2.94 / 147.04 6 65
4 13 1290.60 20 14.82 2175 645 3.58 / 147.68 6 79
5 13 846.72 20 14.93 1556 465 4.04 / 148.15 6 86
6 13 86.32 20 15.18 463 141 4.19 / 148.29 6 72
7 8 0.08 279 15.15 306 1293 5.48 / 149.58 6 137
Average= 5.16
(KJ/cycle)

Cycle 27 GMT 28/10/2019 10:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 29 15.15 450 198 0.20 / 138.92 7 15
2 7 2004.00 40 14.77 3097 1830 2.03 / 140.75 15 58
3 13 1905.60 20 14.75 2976 878 2.91 / 141.62 6 64
4 13 1267.92 20 14.86 2112 628 3.53 / 142.25 6 79
5 13 837.12 20 14.94 1542 461 3.99 / 142.71 6 85
6 13 46.80 20 15.20 397 121 4.11 / 142.83 6 67
7 8 0.04 276 15.16 303 1268 5.38 / 144.10 6 141
Average= 5.15
(KJ/cycle)

Cycle 26 GMT 18/10/2019 13:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 29 15.15 455 200 0.20 / 133.45 7 14
2 7 2004.92 40 14.77 3117 1842 2.04 / 135.29 14 59
3 13 1908.24 20 14.76 2986 881 2.92 / 136.17 6 65
4 13 1357.80 20 14.83 2236 663 3.59 / 136.84 6 77
5 13 804.96 20 14.95 1498 448 4.03 / 137.28 6 86
6 13 115.96 20 15.18 508 154 4.19 / 137.44 6 75
7 8 -0.08 280 15.15 302 1281 5.47 / 138.72 6 129
Average= 5.14
(KJ/cycle)

Cycle 25 GMT 8/10/2019 16:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 29 15.15 465 204 0.20 / 127.95 7 15
2 7 2006.76 40 14.77 3109 1837 2.04 / 129.79 15 58
3 13 1921.96 20 14.76 2991 883 2.92 / 130.67 6 64
4 13 1481.84 20 14.80 2417 715 3.64 / 131.38 6 74
5 13 803.44 20 14.96 1491 446 4.09 / 131.83 6 86
6 13 59.08 20 15.20 410 125 4.21 / 131.95 6 70
7 8 0.00 280 15.16 305 1295 5.50 / 133.25 6 142
Average= 5.12
(KJ/cycle)

Cycle 24 GMT 28/ 9/2019 18:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 29 15.16 467 205 0.21 / 122.39 7 14
2 7 2005.20 40 14.77 3127 1847 2.05 / 124.24 14 60
3 13 1913.88 20 14.75 3009 888 2.94 / 125.13 6 65
4 13 1298.96 20 14.84 2189 650 3.59 / 125.78 6 79
5 13 968.32 20 14.90 1726 514 4.10 / 126.29 6 84
6 13 133.28 20 15.17 546 166 4.27 / 126.46 6 77
7 8 0.04 276 15.16 308 1289 5.56 / 127.74 6 131
Average= 5.11
(KJ/cycle)

Cycle 23 GMT 18/ 9/2019 21:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 29 15.17 449 198 0.20 / 116.91 7 14
2 7 2004.16 40 14.78 3119 1844 2.04 / 118.75 14 59
3 13 1806.00 20 14.78 2857 845 2.89 / 119.59 6 67
4 13 1392.08 20 14.83 2308 685 3.57 / 120.28 6 77
5 13 804.16 20 14.96 1499 449 4.02 / 120.73 6 86
6 13 121.40 20 15.18 531 161 4.18 / 120.89 6 75
7 8 0.04 276 15.16 310 1297 5.48 / 122.19 6 135
Average= 5.09
(KJ/cycle)

Cycle 22 GMT 9/ 9/2019 0:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 29 15.16 465 204 0.20 / 111.35 7 15
2 7 2013.00 40 14.79 3119 1845 2.05 / 113.19 15 58
3 13 1925.68 20 14.76 3032 895 2.94 / 114.09 6 64
4 13 1597.56 20 14.78 2557 756 3.70 / 114.84 6 72
5 13 699.84 20 15.00 1370 411 4.11 / 115.26 6 87
6 13 142.88 20 15.18 559 170 4.28 / 115.43 6 77
7 8 0.08 280 15.17 302 1283 5.56 / 116.71 6 135
Average= 5.07
(KJ/cycle)

Cycle 21 GMT 30/ 8/2019 2:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 28 15.17 466 198 0.20 / 106.10 7 14
2 7 2005.56 40 14.79 3114 1842 2.04 / 107.94 14 59
3 13 1721.88 20 14.81 2731 809 2.85 / 108.75 6 69
4 13 1208.20 20 14.88 2060 613 3.46 / 109.36 6 79
5 13 556.68 20 15.05 1173 353 3.82 / 109.71 6 87
6 13 51.60 20 15.21 411 125 3.94 / 109.84 6 69
7 8 0.00 276 15.17 312 1306 5.25 / 111.14 6 138
Average= 5.05
(KJ/cycle)

Cycle 20 GMT 20/ 8/2019 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 28 15.17 478 203 0.20 / 100.56 7 15
2 7 2005.96 40 14.79 3134 1854 2.06 / 102.42 15 59
3 13 1916.16 20 14.76 3028 894 2.95 / 103.31 6 64
4 13 1182.32 20 14.91 2018 602 3.55 / 103.91 6 79
5 13 978.84 20 14.92 1752 523 4.08 / 104.44 6 83
6 13 75.04 20 15.21 444 135 4.21 / 104.57 6 70
7 8 0.12 279 15.18 313 1326 5.54 / 105.90 6 132
Average= 5.04
(KJ/cycle)

Cycle 19 GMT 10/ 8/2019 7:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 28 15.17 470 200 0.20 / 95.29 7 16
2 7 2003.80 40 14.80 3108 1840 2.04 / 97.13 16 59
3 13 1610.72 20 14.84 2586 768 2.81 / 97.90 6 72
4 13 1112.80 20 14.92 1926 575 3.38 / 98.47 6 81
5 13 809.20 20 14.97 1515 454 3.84 / 98.92 6 86
6 13 39.36 20 15.23 393 120 3.96 / 99.04 6 66
7 8 0.12 274 15.18 317 1319 5.27 / 100.36 6 131
Average= 5.02
(KJ/cycle)

Cycle 18 GMT 31/ 7/2019 10:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 28 15.18 471 200 0.20 / 89.74 7 16
2 7 2004.12 40 14.80 3123 1849 2.05 / 91.59 6 59
3 13 1905.72 20 14.78 2993 885 2.93 / 92.47 6 65
4 13 1581.76 20 14.80 2557 757 3.69 / 93.23 6 74
5 13 672.92 20 15.03 1329 399 4.09 / 93.63 6 88
6 13 102.40 20 15.21 500 152 4.24 / 93.78 6 76
7 8 0.16 278 15.18 310 1308 5.55 / 95.09 6 133
Average= 5.00
(KJ/cycle)

Cycle 17 GMT 21/ 7/2019 13:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 28 15.18 475 202 0.20 / 84.22 7 15
2 7 2011.48 40 14.80 3139 1858 2.06 / 86.08 15 59
3 13 1913.84 20 14.79 2992 885 2.95 / 86.96 6 65
4 13 1374.44 20 14.86 2283 679 3.62 / 87.64 6 77
5 13 715.08 20 15.02 1390 418 4.04 / 88.06 6 87
6 13 69.36 20 15.22 441 134 4.18 / 88.19 6 73
7 8 0.00 278 15.18 319 1346 5.52 / 89.54 6 131
Average= 4.97
(KJ/cycle)

Cycle 16 GMT 11/ 7/2019 15:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 29 15.18 477 210 0.21 / 78.74 7 16
2 7 2002.04 41 14.80 3104 1884 2.09 / 80.62 16 59
3 13 1797.44 20 14.81 2855 846 2.94 / 81.47 6 68
4 13 1260.68 20 14.90 2107 628 3.57 / 82.10 6 80
5 13 702.76 20 15.02 1379 414 3.98 / 82.51 6 89
6 13 58.28 20 15.22 435 132 4.11 / 82.64 6 76
7 8 0.00 282 15.18 321 1374 5.49 / 84.02 6 141
Average= 4.94
(KJ/cycle)

Cycle 15 GMT 1/ 7/2019 18:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 28 15.18 466 198 0.20 / 73.15 7 18
2 10 1000.60 3 15.17 1811 82 0.28 / 73.23 6 59
3 3 907.64 -1 15.52 15 0 0.08 / 73.23 6 59
4 7 2011.52 40 14.81 3139 1860 2.14 / 75.09 59 58
5 13 1914.84 20 14.79 3005 889 3.03 / 75.98 6 64
6 13 1261.76 20 14.90 2124 633 3.66 / 76.62 6 79
7 13 726.00 20 15.02 1396 419 4.08 / 77.03 6 86
8 13 77.24 20 15.22 457 139 4.22 / 77.17 6 75
9 8 -0.08 283 15.19 315 1354 5.57 / 78.53 6 142
Average= 4.91
(KJ/cycle)

Cycle 14 GMT 21/ 6/2019 21:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 28 15.20 456 194 0.19 / 67.65 7 18
2 7 2018.04 40 14.80 3138 1858 2.05 / 69.51 18 60
3 13 1931.68 20 14.79 3041 900 2.95 / 70.41 6 65
4 13 1277.44 20 14.90 2126 634 3.58 / 71.04 6 80
5 13 734.44 20 15.02 1406 422 4.01 / 71.46 6 87
6 13 109.76 20 15.21 509 155 4.16 / 71.62 6 79
7 8 0.00 282 15.19 312 1336 5.50 / 72.95 6 133
Average= 4.86
(KJ/cycle)

Cycle 13 GMT 11/ 6/2019 23:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 28 15.19 452 192 0.19 / 61.94 7 19
2 10 1004.12 3 15.20 1792 82 0.27 / 62.02 6 56
3 3 917.68 -1 15.53 15 0 0.08 / 62.02 6 56
4 7 2005.12 40 14.81 3137 1858 2.13 / 63.88 56 60
5 13 1909.44 20 14.81 2977 882 3.01 / 64.76 6 65
6 13 1710.72 20 14.80 2716 804 3.82 / 65.56 6 71
7 13 777.56 20 15.02 1463 439 4.26 / 66.00 6 86
8 13 104.24 20 15.23 489 149 4.41 / 66.15 6 74
9 8 0.00 283 15.20 303 1303 5.71 / 67.46 6 133
Average= 4.82
(KJ/cycle)

Cycle 12 GMT 2/ 6/2019 2:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 28 15.20 468 199 0.20 / 56.30 7 19
2 7 2001.24 40 14.84 3086 1832 2.03 / 58.13 6 59
3 13 1799.92 20 14.84 2869 852 2.88 / 58.98 6 67
4 13 1412.92 20 14.87 2326 692 3.57 / 59.67 6 77
5 13 943.52 20 14.97 1689 506 4.08 / 60.18 6 84
6 13 221.52 20 15.18 697 212 4.29 / 60.39 6 82
7 8 0.00 287 15.20 311 1357 5.65 / 61.75 6 151
Average= 4.75
(KJ/cycle)

Cycle 11 GMT 23/ 5/2019 5: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 28 15.21 459 195 0.20 / 50.78 7 20
2 7 2004.76 40 14.83 3121 1851 2.05 / 52.63 20 59
3 13 1912.04 20 14.82 2982 884 2.93 / 53.52 6 65
4 13 1356.08 20 14.90 2257 673 3.60 / 54.19 6 78
5 13 802.56 20 15.02 1489 447 4.05 / 54.64 6 86
6 13 110.56 20 15.23 511 156 4.21 / 54.79 6 75
7 8 0.00 276 15.21 311 1306 5.51 / 56.10 6 134
Average= 4.67
(KJ/cycle)

Cycle 10 GMT 13/ 5/2019 7:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 28 15.20 463 197 0.20 / 45.42 7 23
2 7 2009.24 40 14.84 3105 1843 2.04 / 47.26 23 60
3 13 1722.28 20 14.86 2724 810 2.85 / 48.07 6 70
4 13 1286.60 20 14.91 2154 642 3.49 / 48.71 6 80
5 13 727.88 20 15.04 1402 422 3.91 / 49.14 6 88
6 13 65.36 20 15.25 432 132 4.05 / 49.27 6 71
7 8 0.08 276 15.21 314 1318 5.36 / 50.59 6 129
Average= 4.60
(KJ/cycle)

Cycle 9 GMT 3/ 5/2019 10:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 28 15.21 469 200 0.20 / 39.68 7 23
2 7 2005.92 41 14.83 3132 1904 2.10 / 41.59 23 61
3 13 1915.00 20 14.83 3001 890 2.99 / 42.48 6 67
4 13 1479.80 20 14.88 2390 711 3.71 / 43.19 6 77
5 13 694.96 20 15.06 1346 405 4.11 / 43.59 6 89
6 13 468.24 20 15.11 1040 314 4.43 / 43.91 6 89
7 8 0.08 278 15.20 311 1314 5.74 / 45.22 6 145
Average= 4.52
(KJ/cycle)

Cycle 8 GMT 23/ 4/2019 13: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 28 15.22 461 196 0.20 / 34.28 7 23
2 7 2008.84 40 14.84 3114 1848 2.04 / 36.13 23 62
3 13 1914.60 20 14.82 3026 897 2.94 / 37.03 6 68
4 13 1336.12 20 14.91 2210 659 3.60 / 37.69 6 81
5 13 566.32 20 15.10 1191 360 3.96 / 38.05 6 91
6 13 22.60 20 15.27 364 111 4.07 / 38.16 6 72
7 8 0.08 274 15.22 317 1322 5.39 / 39.48 6 133
Average= 4.39
(KJ/cycle)

Cycle 7 GMT 13/ 4/2019 15:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 28 15.22 472 201 0.20 / 28.93 7 22
2 7 2010.88 40 14.84 3118 1851 2.05 / 30.78 22 63
3 13 1808.24 20 14.85 2852 847 2.90 / 31.63 6 71
4 13 1392.76 20 14.90 2297 685 3.58 / 32.31 6 80
5 13 590.32 20 15.10 1220 368 3.95 / 32.68 6 91
6 13 66.16 20 15.26 426 130 4.08 / 32.81 6 72
7 8 0.04 274 15.23 306 1277 5.36 / 34.09 6 130
Average= 4.26
(KJ/cycle)

Cycle 6 GMT 3/ 4/2019 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 24 15.23 465 170 0.17 / 23.44 7 20
2 10 1076.76 4 15.17 1912 116 0.29 / 23.56 6 55
3 3 1037.80 1 15.22 1874 29 0.31 / 23.59 6 32
4 7 2013.80 40 14.84 3133 1860 2.17 / 25.45 32 63
5 13 1919.64 20 14.81 3047 903 3.08 / 26.35 6 68
6 13 1176.56 20 14.95 2016 603 3.68 / 26.95 6 84
7 13 653.00 20 15.07 1306 394 4.07 / 27.35 6 91
8 13 17.88 20 15.28 352 108 4.18 / 27.45 6 69
9 8 0.12 270 15.23 310 1275 5.46 / 28.73 6 138
Average= 4.10
(KJ/cycle)

Cycle 5 GMT 24/ 3/2019 20:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 31 15.23 464 219 0.22 / 18.14 7 22
2 3 800.04 -3 15.57 15 0 0.00 / 18.14 7 22
3 7 2005.24 40 14.85 3106 1845 2.06 / 19.98 22 60
4 13 1910.96 20 14.84 2999 890 2.95 / 20.88 6 66
5 13 1174.48 20 14.96 2000 598 3.55 / 21.47 6 81
6 13 730.64 20 15.06 1394 420 3.97 / 21.89 6 87
7 8 0.08 298 15.24 304 1381 5.35 / 23.27 6 132
Average= 3.88
(KJ/cycle)

Cycle 4 GMT 14/ 3/2019 22:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 27 15.23 461 190 0.19 / 13.48 7 23
2 7 1507.88 40 15.04 2439 1467 1.66 / 14.94 6 64
3 13 1438.44 20 15.03 2341 704 2.36 / 15.65 6 68
4 13 1129.64 20 15.04 1929 580 2.94 / 16.23 6 76
5 13 582.28 20 15.14 1197 362 3.30 / 16.59 6 86
6 8 0.16 289 15.26 302 1332 4.64 / 17.92 6 133
Average= 3.58
(KJ/cycle)

Cycle 3 GMT 13/ 3/2019 11:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 23 15.23 443 155 0.16 / 8.72 7 24
2 10 1009.32 4 15.18 1806 110 0.26 / 8.83 6 53
3 7 1504.08 40 15.04 2431 1462 1.73 / 10.29 53 66
4 13 1413.20 20 15.02 2328 699 2.43 / 10.99 6 70
5 13 1214.16 20 15.01 2047 615 3.04 / 11.61 6 76
6 13 507.92 20 15.17 1098 333 3.37 / 11.94 6 86
7 8 0.16 290 15.26 304 1345 4.72 / 13.29 6 138
Average= 3.32
(KJ/cycle)

Cycle 2 GMT 12/ 3/2019 1:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 31 15.26 454 215 0.21 / 4.39 7 27
2 3 781.16 -3 15.56 14 0 0.00 / 4.39 7 27
3 7 1405.68 40 15.07 2327 1403 1.62 / 5.79 27 68
4 13 1350.72 20 15.06 2237 674 2.29 / 6.47 6 70
5 13 1256.36 20 15.02 2094 629 2.92 / 7.10 6 75
6 13 231.40 20 15.25 684 209 3.13 / 7.31 6 82
7 8 0.20 282 15.26 293 1261 4.39 / 8.57 6 129
Average= 2.86
(KJ/cycle)

Cycle 1 GMT 10/ 3/2019 15:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 31 15.45 422 202 0.20 / 1.73 7 20
2 3 759.04 -4 15.57 15 0 0.00 / 1.73 7 20
3 7 788.56 40 15.24 1480 902 1.10 / 2.63 20 70
4 13 449.52 20 15.28 997 305 1.41 / 2.93 6 78
5 8 0.04 278 15.31 292 1243 2.65 / 4.18 6 130
Average= 2.09
(KJ/cycle)

Cycle 0 GMT 10/ 3/2019 5:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.00 30 15.61 352 165 0.16 / 0.16 7 19
2 7 64.04 40 15.59 353 220 0.38 / 0.38 19 25
3 8 0.12 291 15.54 252 1140 1.52 / 1.52 7 131
Average= 1.52
(KJ/cycle)