SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 24 | 14.86 | 451 | 161 | 0.16 / 1128.77 | 6 | 13 |
2 | 7 | 2003.16 | 40 | 14.54 | 3120 | 1815 | 1.98 / 1130.58 | 13 | 60 |
3 | 13 | 1918.08 | 20 | 14.49 | 3031 | 878 | 2.85 / 1131.46 | 6 | 61 |
4 | 13 | 1367.36 | 20 | 14.52 | 2268 | 659 | 3.51 / 1132.12 | 6 | 74 |
5 | 13 | 618.88 | 20 | 14.71 | 1235 | 363 | 3.88 / 1132.48 | 6 | 85 |
6 | 13 | 48.04 | 20 | 14.90 | 381 | 114 | 3.99 / 1132.59 | 6 | 73 |
7 | 8 | 0.52 | 272 | 14.86 | 296 | 1196 | 5.19 / 1133.79 | 6 | 132 |
Average= | 12.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 25 | 14.88 | 453 | 169 | 0.17 / 1123.34 | 6 | 14 |
2 | 7 | 2005.40 | 40 | 14.55 | 3088 | 1797 | 1.97 / 1125.14 | 14 | 59 |
3 | 13 | 1915.64 | 20 | 14.51 | 3003 | 871 | 2.84 / 1126.01 | 6 | 63 |
4 | 13 | 1359.96 | 20 | 14.53 | 2222 | 646 | 3.48 / 1126.66 | 6 | 74 |
5 | 13 | 912.96 | 20 | 14.61 | 1652 | 483 | 3.97 / 1127.14 | 6 | 82 |
6 | 13 | 208.72 | 20 | 14.83 | 637 | 189 | 4.15 / 1127.33 | 6 | 83 |
7 | 13 | 25.12 | 20 | 14.88 | 352 | 105 | 4.26 / 1127.43 | 6 | 75 |
8 | 8 | 0.04 | 259 | 14.84 | 305 | 1172 | 5.43 / 1128.60 | 6 | 138 |
Average= | 12.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 24 | 14.88 | 451 | 161 | 0.16 / 1118.05 | 6 | 11 |
2 | 3 | 1019.68 | 1 | 14.97 | 1844 | 28 | 0.19 / 1118.08 | 6 | 10 |
3 | 7 | 2006.84 | 40 | 14.54 | 3095 | 1800 | 1.99 / 1119.88 | 10 | 58 |
4 | 13 | 1814.64 | 20 | 14.52 | 2843 | 826 | 2.81 / 1120.70 | 6 | 64 |
5 | 13 | 1379.12 | 20 | 14.52 | 2286 | 664 | 3.48 / 1121.36 | 6 | 73 |
6 | 13 | 824.56 | 20 | 14.63 | 1522 | 445 | 3.92 / 1121.81 | 6 | 82 |
7 | 13 | 73.08 | 20 | 14.88 | 427 | 127 | 4.05 / 1121.94 | 6 | 75 |
8 | 8 | -0.80 | 272 | 14.85 | 306 | 1236 | 5.29 / 1123.17 | 6 | 132 |
Average= | 13.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 24 | 14.88 | 434 | 155 | 0.15 / 1112.85 | 6 | 12 |
2 | 3 | 1031.04 | 1 | 14.96 | 1854 | 28 | 0.18 / 1112.87 | 6 | 29 |
3 | 7 | 2005.60 | 40 | 14.55 | 3117 | 1814 | 2.00 / 1114.69 | 29 | 59 |
4 | 13 | 1910.56 | 20 | 14.50 | 3005 | 871 | 2.87 / 1115.56 | 6 | 62 |
5 | 13 | 1170.44 | 20 | 14.57 | 2004 | 584 | 3.45 / 1116.14 | 6 | 75 |
6 | 13 | 649.36 | 20 | 14.69 | 1288 | 378 | 3.83 / 1116.52 | 6 | 84 |
7 | 13 | 50.52 | 20 | 14.89 | 399 | 119 | 3.95 / 1116.64 | 6 | 75 |
8 | 8 | 0.24 | 276 | 14.85 | 304 | 1246 | 5.20 / 1117.89 | 6 | 135 |
Average= | 13.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 24 | 14.87 | 440 | 157 | 0.16 / 1107.44 | 6 | 14 |
2 | 7 | 2027.32 | 40 | 14.52 | 3176 | 1845 | 2.00 / 1109.28 | 14 | 59 |
3 | 13 | 1943.96 | 20 | 14.49 | 3059 | 886 | 2.89 / 1110.17 | 6 | 63 |
4 | 13 | 1276.92 | 20 | 14.53 | 2170 | 631 | 3.52 / 1110.80 | 6 | 73 |
5 | 13 | 952.00 | 20 | 14.59 | 1711 | 499 | 4.02 / 1111.30 | 6 | 82 |
6 | 13 | 131.00 | 20 | 14.86 | 519 | 154 | 4.17 / 1111.45 | 6 | 80 |
7 | 13 | 24.88 | 20 | 14.88 | 344 | 102 | 4.27 / 1111.55 | 6 | 76 |
8 | 8 | -0.24 | 257 | 14.84 | 298 | 1137 | 5.41 / 1112.69 | 6 | 134 |
Average= | 13.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 25 | 14.87 | 437 | 162 | 0.16 / 1102.22 | 6 | 14 |
2 | 3 | 950.12 | -1 | 15.26 | 12 | 0 | 0.00 / 1102.22 | 6 | 14 |
3 | 7 | 2006.00 | 40 | 14.55 | 3118 | 1815 | 1.98 / 1104.03 | 14 | 58 |
4 | 13 | 1910.24 | 20 | 14.51 | 3005 | 872 | 2.85 / 1104.90 | 6 | 62 |
5 | 13 | 1193.52 | 20 | 14.56 | 2045 | 596 | 3.44 / 1105.50 | 6 | 75 |
6 | 13 | 766.44 | 20 | 14.65 | 1461 | 428 | 3.87 / 1105.93 | 6 | 82 |
7 | 13 | 87.12 | 20 | 14.87 | 453 | 135 | 4.01 / 1106.06 | 6 | 76 |
8 | 13 | 16.56 | 20 | 14.89 | 340 | 101 | 4.11 / 1106.16 | 6 | 75 |
9 | 8 | 0.24 | 246 | 14.83 | 306 | 1116 | 5.23 / 1107.28 | 6 | 131 |
Average= | 13.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 24 | 14.88 | 455 | 162 | 0.16 / 1096.72 | 6 | 15 |
2 | 10 | 1010.48 | 3 | 14.92 | 1809 | 81 | 0.24 / 1096.80 | 6 | 58 |
3 | 3 | 937.44 | -1 | 15.26 | 12 | 0 | 0.08 / 1096.80 | 6 | 58 |
4 | 7 | 2007.32 | 40 | 14.55 | 3119 | 1815 | 2.06 / 1098.61 | 58 | 59 |
5 | 13 | 1913.80 | 20 | 14.50 | 3010 | 873 | 2.93 / 1099.49 | 6 | 63 |
6 | 13 | 1603.36 | 20 | 14.47 | 2592 | 750 | 3.68 / 1100.24 | 6 | 70 |
7 | 13 | 787.92 | 20 | 14.65 | 1472 | 431 | 4.11 / 1100.67 | 6 | 82 |
8 | 13 | 118.44 | 20 | 14.86 | 495 | 147 | 4.26 / 1100.81 | 6 | 79 |
9 | 8 | 0.04 | 276 | 14.84 | 303 | 1241 | 5.50 / 1102.05 | 6 | 129 |
Average= | 13.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 24 | 14.88 | 444 | 159 | 0.16 / 1091.37 | 6 | 11 |
2 | 7 | 2002.44 | 40 | 14.55 | 3127 | 1820 | 1.98 / 1093.19 | 11 | 57 |
3 | 13 | 1910.24 | 20 | 14.50 | 3032 | 879 | 2.86 / 1094.07 | 6 | 63 |
4 | 13 | 1259.52 | 20 | 14.54 | 2137 | 621 | 3.48 / 1094.69 | 6 | 76 |
5 | 13 | 1050.32 | 20 | 14.57 | 1832 | 534 | 4.01 / 1095.22 | 6 | 76 |
6 | 13 | 72.76 | 20 | 14.88 | 433 | 129 | 4.14 / 1095.35 | 6 | 74 |
7 | 8 | 0.40 | 270 | 14.85 | 300 | 1203 | 5.34 / 1096.55 | 6 | 130 |
Average= | 13.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 23 | 14.88 | 436 | 149 | 0.15 / 1086.18 | 6 | 12 |
2 | 3 | 1033.76 | 1 | 14.95 | 1859 | 28 | 0.18 / 1086.20 | 6 | 27 |
3 | 7 | 2003.56 | 40 | 14.55 | 3110 | 1810 | 1.99 / 1088.01 | 27 | 57 |
4 | 13 | 1909.60 | 20 | 14.51 | 2994 | 869 | 2.86 / 1088.88 | 6 | 61 |
5 | 13 | 1171.84 | 20 | 14.57 | 1999 | 583 | 3.44 / 1089.47 | 6 | 75 |
6 | 13 | 661.20 | 20 | 14.69 | 1304 | 383 | 3.82 / 1089.85 | 6 | 82 |
7 | 13 | 51.24 | 20 | 14.88 | 401 | 119 | 3.94 / 1089.97 | 6 | 73 |
8 | 8 | -0.16 | 276 | 14.84 | 303 | 1241 | 5.18 / 1091.21 | 6 | 132 |
Average= | 13.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 25 | 14.88 | 430 | 160 | 0.16 / 1080.96 | 6 | 14 |
2 | 3 | 937.16 | -1 | 15.27 | 12 | 0 | 0.00 / 1080.96 | 6 | 14 |
3 | 7 | 2008.84 | 40 | 14.55 | 3102 | 1805 | 1.97 / 1082.76 | 14 | 57 |
4 | 13 | 1915.92 | 20 | 14.51 | 2989 | 867 | 2.83 / 1083.63 | 6 | 62 |
5 | 13 | 1294.60 | 20 | 14.54 | 2167 | 630 | 3.46 / 1084.26 | 6 | 72 |
6 | 13 | 755.72 | 20 | 14.66 | 1424 | 418 | 3.88 / 1084.68 | 6 | 81 |
7 | 13 | 45.32 | 20 | 14.89 | 379 | 113 | 3.99 / 1084.79 | 6 | 74 |
8 | 8 | -0.28 | 278 | 14.84 | 300 | 1238 | 5.23 / 1086.03 | 6 | 134 |
Average= | 13.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 24 | 14.88 | 443 | 158 | 0.16 / 1075.58 | 6 | 15 |
2 | 10 | 1004.80 | 3 | 14.91 | 1812 | 81 | 0.24 / 1075.66 | 6 | 55 |
3 | 3 | 955.84 | -1 | 15.26 | 13 | 0 | 0.08 / 1075.66 | 6 | 55 |
4 | 7 | 2004.08 | 40 | 14.54 | 3112 | 1810 | 2.05 / 1077.47 | 55 | 58 |
5 | 13 | 1907.72 | 20 | 14.51 | 2995 | 869 | 2.92 / 1078.34 | 6 | 62 |
6 | 13 | 1247.36 | 20 | 14.54 | 2122 | 617 | 3.54 / 1078.96 | 6 | 74 |
7 | 13 | 936.64 | 20 | 14.60 | 1686 | 492 | 4.03 / 1079.45 | 6 | 80 |
8 | 13 | 37.20 | 20 | 14.89 | 375 | 112 | 4.14 / 1079.56 | 6 | 73 |
9 | 8 | 0.64 | 274 | 14.84 | 303 | 1232 | 5.37 / 1080.80 | 6 | 131 |
Average= | 13.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 23 | 14.86 | 457 | 156 | 0.16 / 1070.31 | 6 | 12 |
2 | 7 | 2004.48 | 40 | 14.55 | 3091 | 1799 | 1.96 / 1072.11 | 6 | 59 |
3 | 13 | 1811.80 | 20 | 14.53 | 2840 | 825 | 2.78 / 1072.93 | 6 | 63 |
4 | 13 | 1489.80 | 20 | 14.49 | 2434 | 705 | 3.49 / 1073.64 | 6 | 70 |
5 | 13 | 787.92 | 20 | 14.65 | 1479 | 433 | 3.92 / 1074.07 | 6 | 83 |
6 | 13 | 97.16 | 20 | 14.86 | 466 | 138 | 4.06 / 1074.21 | 6 | 77 |
7 | 8 | 0.32 | 276 | 14.84 | 297 | 1216 | 5.27 / 1075.42 | 6 | 130 |
Average= | 13.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 24 | 14.87 | 433 | 155 | 0.15 / 1065.05 | 6 | 12 |
2 | 7 | 2010.16 | 40 | 14.56 | 3102 | 1807 | 1.96 / 1066.85 | 12 | 57 |
3 | 13 | 1911.48 | 20 | 14.53 | 2986 | 868 | 2.83 / 1067.72 | 6 | 60 |
4 | 13 | 1344.76 | 20 | 14.54 | 2226 | 647 | 3.48 / 1068.37 | 6 | 74 |
5 | 13 | 786.80 | 20 | 14.65 | 1465 | 429 | 3.91 / 1068.80 | 6 | 80 |
6 | 13 | 62.72 | 20 | 14.88 | 413 | 123 | 4.03 / 1068.92 | 6 | 73 |
7 | 8 | -0.40 | 276 | 14.84 | 300 | 1229 | 5.26 / 1070.15 | 6 | 133 |
Average= | 14.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 24 | 14.86 | 427 | 152 | 0.15 / 1059.71 | 6 | 13 |
2 | 7 | 2003.80 | 41 | 14.54 | 3117 | 1858 | 2.01 / 1061.56 | 13 | 58 |
3 | 13 | 1798.80 | 20 | 14.53 | 2835 | 824 | 2.83 / 1062.39 | 6 | 66 |
4 | 13 | 1482.08 | 20 | 14.50 | 2431 | 705 | 3.54 / 1063.09 | 6 | 73 |
5 | 13 | 822.88 | 20 | 14.63 | 1522 | 445 | 3.98 / 1063.54 | 6 | 82 |
6 | 13 | 73.96 | 20 | 14.87 | 438 | 130 | 4.11 / 1063.67 | 6 | 74 |
7 | 8 | 0.52 | 276 | 14.84 | 299 | 1225 | 5.34 / 1064.89 | 6 | 136 |
Average= | 14.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 24 | 14.85 | 440 | 157 | 0.16 / 1054.36 | 6 | 14 |
2 | 7 | 2004.68 | 40 | 14.54 | 3122 | 1816 | 1.97 / 1056.17 | 14 | 58 |
3 | 13 | 1907.48 | 20 | 14.51 | 2985 | 866 | 2.84 / 1057.04 | 6 | 64 |
4 | 13 | 1266.48 | 20 | 14.54 | 2149 | 625 | 3.46 / 1057.66 | 6 | 75 |
5 | 13 | 805.68 | 20 | 14.64 | 1493 | 437 | 3.90 / 1058.10 | 6 | 81 |
6 | 13 | 232.52 | 20 | 14.81 | 665 | 197 | 4.10 / 1058.30 | 6 | 82 |
7 | 13 | 17.68 | 20 | 14.88 | 333 | 99 | 4.20 / 1058.40 | 6 | 75 |
8 | 8 | 0.44 | 261 | 14.82 | 299 | 1157 | 5.35 / 1059.55 | 6 | 137 |
Average= | 14.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 24 | 14.86 | 443 | 158 | 0.16 / 1048.96 | 6 | 14 |
2 | 7 | 2003.92 | 40 | 14.55 | 3108 | 1809 | 1.97 / 1050.77 | 14 | 57 |
3 | 13 | 1909.32 | 20 | 14.52 | 2990 | 868 | 2.84 / 1051.64 | 6 | 63 |
4 | 13 | 1267.60 | 20 | 14.55 | 2132 | 620 | 3.46 / 1052.26 | 6 | 76 |
5 | 13 | 826.08 | 20 | 14.62 | 1525 | 446 | 3.90 / 1052.71 | 6 | 82 |
6 | 13 | 371.60 | 20 | 14.75 | 881 | 260 | 4.16 / 1052.97 | 6 | 84 |
7 | 13 | 11.24 | 20 | 14.88 | 318 | 95 | 4.26 / 1053.06 | 6 | 74 |
8 | 8 | 0.40 | 259 | 14.82 | 297 | 1140 | 5.40 / 1054.20 | 6 | 142 |
Average= | 14.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 24 | 14.86 | 445 | 159 | 0.16 / 1043.63 | 6 | 14 |
2 | 7 | 2009.72 | 40 | 14.55 | 3098 | 1803 | 1.96 / 1045.43 | 14 | 58 |
3 | 13 | 1809.52 | 20 | 14.53 | 2845 | 827 | 2.79 / 1046.25 | 6 | 66 |
4 | 13 | 1494.60 | 20 | 14.50 | 2431 | 705 | 3.49 / 1046.96 | 6 | 71 |
5 | 13 | 921.76 | 20 | 14.60 | 1670 | 488 | 3.98 / 1047.45 | 6 | 80 |
6 | 13 | 58.64 | 20 | 14.88 | 403 | 120 | 4.10 / 1047.57 | 6 | 73 |
7 | 8 | 0.08 | 276 | 14.84 | 302 | 1237 | 5.34 / 1048.80 | 6 | 131 |
Average= | 14.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 24 | 14.87 | 432 | 154 | 0.15 / 1038.47 | 6 | 13 |
2 | 7 | 2006.52 | 41 | 14.55 | 3092 | 1845 | 2.00 / 1040.32 | 13 | 59 |
3 | 13 | 1912.80 | 20 | 14.53 | 2970 | 863 | 2.86 / 1041.18 | 6 | 63 |
4 | 13 | 1256.20 | 20 | 14.55 | 2109 | 614 | 3.48 / 1041.79 | 6 | 75 |
5 | 13 | 596.24 | 20 | 14.70 | 1200 | 353 | 3.83 / 1042.15 | 6 | 84 |
6 | 13 | 68.36 | 20 | 14.87 | 408 | 121 | 3.95 / 1042.27 | 6 | 77 |
7 | 8 | -0.20 | 274 | 14.84 | 295 | 1200 | 5.15 / 1043.47 | 6 | 130 |
Average= | 14.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 24 | 14.86 | 454 | 162 | 0.16 / 1033.15 | 6 | 13 |
2 | 3 | 1019.00 | 1 | 14.98 | 1826 | 27 | 0.19 / 1033.17 | 6 | 16 |
3 | 7 | 2004.32 | 40 | 14.55 | 3121 | 1816 | 2.01 / 1034.99 | 16 | 58 |
4 | 13 | 1911.96 | 20 | 14.51 | 3010 | 874 | 2.88 / 1035.86 | 6 | 61 |
5 | 13 | 1368.76 | 20 | 14.52 | 2249 | 653 | 3.53 / 1036.52 | 6 | 74 |
6 | 13 | 715.16 | 20 | 14.66 | 1376 | 403 | 3.94 / 1036.92 | 6 | 84 |
7 | 13 | 153.48 | 20 | 14.84 | 551 | 164 | 4.10 / 1037.08 | 6 | 78 |
8 | 8 | -0.12 | 278 | 14.83 | 299 | 1233 | 5.33 / 1038.32 | 6 | 143 |
Average= | 14.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 23 | 14.84 | 448 | 153 | 0.15 / 1027.73 | 6 | 16 |
2 | 7 | 2008.60 | 40 | 14.54 | 3142 | 1827 | 1.98 / 1029.56 | 16 | 58 |
3 | 13 | 1916.96 | 20 | 14.50 | 3025 | 877 | 2.86 / 1030.44 | 6 | 62 |
4 | 13 | 1294.16 | 20 | 14.54 | 2173 | 632 | 3.49 / 1031.07 | 6 | 73 |
5 | 13 | 1083.60 | 20 | 14.55 | 1860 | 541 | 4.03 / 1031.61 | 6 | 77 |
6 | 13 | 112.04 | 20 | 14.85 | 492 | 146 | 4.18 / 1031.76 | 6 | 75 |
7 | 8 | 0.00 | 278 | 14.83 | 298 | 1229 | 5.41 / 1032.99 | 6 | 136 |
Average= | 14.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 23 | 14.84 | 458 | 156 | 0.16 / 1022.24 | 6 | 15 |
2 | 7 | 2017.40 | 40 | 14.54 | 3151 | 1833 | 1.99 / 1024.07 | 15 | 58 |
3 | 13 | 1940.20 | 20 | 14.50 | 3039 | 881 | 2.87 / 1024.95 | 6 | 62 |
4 | 13 | 1389.68 | 20 | 14.52 | 2283 | 663 | 3.53 / 1025.62 | 6 | 74 |
5 | 13 | 743.60 | 20 | 14.65 | 1430 | 419 | 3.95 / 1026.04 | 6 | 83 |
6 | 13 | 397.88 | 20 | 14.74 | 918 | 271 | 4.22 / 1026.31 | 6 | 84 |
7 | 13 | 27.52 | 20 | 14.86 | 358 | 106 | 4.33 / 1026.41 | 6 | 75 |
8 | 8 | -0.16 | 259 | 14.81 | 304 | 1166 | 5.50 / 1027.58 | 6 | 134 |
Average= | 15.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 24 | 14.85 | 427 | 152 | 0.15 / 1016.77 | 6 | 17 |
2 | 7 | 2003.68 | 40 | 14.54 | 3117 | 1813 | 1.97 / 1018.58 | 17 | 59 |
3 | 13 | 1802.32 | 20 | 14.53 | 2844 | 826 | 2.79 / 1019.41 | 6 | 66 |
4 | 13 | 1609.20 | 20 | 14.48 | 2595 | 752 | 3.54 / 1020.16 | 6 | 70 |
5 | 13 | 912.80 | 20 | 14.58 | 1677 | 489 | 4.03 / 1020.65 | 6 | 79 |
6 | 13 | 224.28 | 20 | 14.80 | 652 | 193 | 4.23 / 1020.84 | 6 | 81 |
7 | 13 | 52.04 | 20 | 14.86 | 377 | 112 | 4.34 / 1020.96 | 6 | 74 |
8 | 8 | 0.00 | 259 | 14.82 | 294 | 1128 | 5.47 / 1022.08 | 6 | 132 |
Average= | 15.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 24 | 14.86 | 450 | 160 | 0.16 / 1011.34 | 6 | 15 |
2 | 7 | 2011.76 | 40 | 14.54 | 3151 | 1833 | 1.99 / 1013.17 | 15 | 59 |
3 | 13 | 1922.28 | 20 | 14.51 | 3034 | 880 | 2.87 / 1014.05 | 6 | 63 |
4 | 13 | 1381.72 | 20 | 14.52 | 2291 | 665 | 3.54 / 1014.72 | 6 | 73 |
5 | 13 | 724.56 | 20 | 14.65 | 1397 | 409 | 3.95 / 1015.13 | 6 | 82 |
6 | 13 | 291.12 | 20 | 14.78 | 751 | 222 | 4.17 / 1015.35 | 6 | 82 |
7 | 13 | 27.64 | 20 | 14.86 | 355 | 106 | 4.28 / 1015.46 | 6 | 77 |
8 | 8 | 0.56 | 261 | 14.81 | 301 | 1163 | 5.44 / 1016.62 | 6 | 132 |
Average= | 15.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 24 | 14.84 | 455 | 162 | 0.16 / 1006.11 | 6 | 18 |
2 | 7 | 2002.28 | 40 | 14.55 | 3128 | 1820 | 1.98 / 1007.93 | 18 | 58 |
3 | 13 | 1915.76 | 20 | 14.52 | 2995 | 870 | 2.85 / 1008.80 | 6 | 63 |
4 | 13 | 1386.56 | 20 | 14.52 | 2309 | 671 | 3.52 / 1009.47 | 6 | 73 |
5 | 13 | 620.40 | 20 | 14.69 | 1238 | 364 | 3.89 / 1009.83 | 6 | 83 |
6 | 13 | 53.76 | 20 | 14.87 | 398 | 118 | 4.00 / 1009.95 | 6 | 75 |
7 | 8 | 0.24 | 274 | 14.83 | 302 | 1227 | 5.23 / 1011.18 | 6 | 130 |
Average= | 15.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 26 | 14.86 | 438 | 169 | 0.17 / 1000.97 | 6 | 21 |
2 | 3 | 906.76 | -1 | 15.27 | 12 | 0 | 0.00 / 1000.97 | 6 | 21 |
3 | 7 | 2006.84 | 40 | 14.55 | 3143 | 1829 | 2.00 / 1002.80 | 21 | 59 |
4 | 13 | 1936.40 | 20 | 14.51 | 3037 | 881 | 2.88 / 1003.68 | 6 | 62 |
5 | 13 | 1186.24 | 20 | 14.56 | 2028 | 591 | 3.47 / 1004.27 | 6 | 75 |
6 | 13 | 575.32 | 20 | 14.70 | 1183 | 348 | 3.82 / 1004.62 | 6 | 83 |
7 | 13 | 137.12 | 20 | 14.83 | 523 | 155 | 3.97 / 1004.77 | 6 | 78 |
8 | 13 | 11.92 | 20 | 14.87 | 325 | 97 | 4.07 / 1004.87 | 6 | 78 |
9 | 8 | 0.16 | 242 | 14.82 | 301 | 1080 | 5.15 / 1005.95 | 6 | 129 |
Average= | 15.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 26 | 14.83 | 442 | 170 | 0.17 / 995.61 | 6 | 19 |
2 | 7 | 2010.16 | 40 | 14.55 | 3121 | 1816 | 1.99 / 997.43 | 19 | 56 |
3 | 13 | 1824.12 | 20 | 14.52 | 2897 | 841 | 2.83 / 998.27 | 6 | 63 |
4 | 13 | 1509.28 | 20 | 14.49 | 2484 | 720 | 3.55 / 998.99 | 6 | 71 |
5 | 13 | 942.00 | 20 | 14.58 | 1704 | 497 | 4.04 / 999.49 | 6 | 80 |
6 | 13 | 79.76 | 20 | 14.86 | 435 | 129 | 4.17 / 999.61 | 6 | 75 |
7 | 8 | 0.08 | 267 | 14.83 | 299 | 1184 | 5.36 / 1000.80 | 6 | 132 |
Average= | 15.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 26 | 14.86 | 429 | 166 | 0.17 / 990.26 | 6 | 17 |
2 | 7 | 2014.24 | 40 | 14.56 | 3110 | 1811 | 1.98 / 992.07 | 17 | 54 |
3 | 13 | 1929.48 | 20 | 14.52 | 2997 | 870 | 2.85 / 992.94 | 6 | 59 |
4 | 13 | 1283.36 | 20 | 14.54 | 2162 | 629 | 3.48 / 993.57 | 6 | 74 |
5 | 13 | 871.00 | 20 | 14.60 | 1592 | 465 | 3.94 / 994.03 | 6 | 79 |
6 | 13 | 188.56 | 20 | 14.81 | 609 | 180 | 4.12 / 994.21 | 6 | 80 |
7 | 13 | 17.04 | 20 | 14.86 | 346 | 103 | 4.22 / 994.31 | 6 | 75 |
8 | 8 | -0.04 | 250 | 14.81 | 304 | 1126 | 5.35 / 995.44 | 6 | 135 |
Average= | 16.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 27 | 14.83 | 441 | 177 | 0.18 / 984.92 | 6 | 21 |
2 | 3 | 947.20 | -1 | 15.27 | 12 | 0 | 0.00 / 984.92 | 6 | 21 |
3 | 7 | 2008.00 | 41 | 14.55 | 3134 | 1870 | 2.05 / 986.79 | 21 | 57 |
4 | 13 | 1928.32 | 20 | 14.53 | 3014 | 876 | 2.92 / 987.66 | 6 | 63 |
5 | 13 | 1410.52 | 20 | 14.52 | 2325 | 675 | 3.60 / 988.34 | 6 | 71 |
6 | 13 | 752.36 | 20 | 14.64 | 1427 | 418 | 4.02 / 988.76 | 6 | 80 |
7 | 13 | 100.56 | 20 | 14.85 | 457 | 136 | 4.15 / 988.89 | 6 | 77 |
8 | 8 | 0.16 | 274 | 14.83 | 295 | 1199 | 5.35 / 990.09 | 6 | 139 |
Average= | 16.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 26 | 14.84 | 453 | 175 | 0.17 / 979.30 | 6 | 21 |
2 | 3 | 1027.88 | 1 | 14.98 | 1812 | 27 | 0.20 / 979.32 | 6 | 30 |
3 | 7 | 2012.44 | 40 | 14.57 | 3139 | 1829 | 2.03 / 981.15 | 30 | 56 |
4 | 13 | 1916.36 | 20 | 14.53 | 3015 | 876 | 2.91 / 982.03 | 6 | 60 |
5 | 13 | 1371.96 | 20 | 14.53 | 2291 | 666 | 3.57 / 982.69 | 6 | 71 |
6 | 13 | 965.20 | 20 | 14.59 | 1727 | 504 | 4.08 / 983.20 | 6 | 79 |
7 | 13 | 397.92 | 20 | 14.74 | 915 | 270 | 4.35 / 983.47 | 6 | 82 |
8 | 13 | 31.92 | 20 | 14.86 | 358 | 106 | 4.45 / 983.57 | 6 | 77 |
9 | 8 | 0.56 | 261 | 14.81 | 302 | 1167 | 5.62 / 984.74 | 6 | 130 |
Average= | 16.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 27 | 14.84 | 439 | 176 | 0.18 / 973.85 | 6 | 19 |
2 | 7 | 2005.68 | 40 | 14.57 | 3102 | 1808 | 1.98 / 975.66 | 19 | 58 |
3 | 13 | 1913.32 | 20 | 14.54 | 2976 | 865 | 2.85 / 976.52 | 6 | 63 |
4 | 13 | 1484.08 | 20 | 14.51 | 2421 | 703 | 3.55 / 977.23 | 6 | 71 |
5 | 13 | 829.12 | 20 | 14.62 | 1525 | 446 | 4.00 / 977.67 | 6 | 80 |
6 | 13 | 275.76 | 20 | 14.78 | 738 | 218 | 4.22 / 977.89 | 6 | 80 |
7 | 8 | -0.52 | 276 | 14.82 | 301 | 1231 | 5.45 / 979.12 | 6 | 130 |
Average= | 16.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 27 | 14.84 | 452 | 181 | 0.18 / 968.22 | 6 | 20 |
2 | 7 | 2011.56 | 40 | 14.57 | 3129 | 1824 | 2.00 / 970.05 | 20 | 57 |
3 | 13 | 1922.20 | 20 | 14.52 | 3020 | 877 | 2.88 / 970.93 | 6 | 60 |
4 | 13 | 1610.68 | 20 | 14.50 | 2587 | 750 | 3.63 / 971.68 | 6 | 68 |
5 | 13 | 1138.80 | 20 | 14.53 | 1955 | 568 | 4.20 / 972.24 | 6 | 76 |
6 | 13 | 209.56 | 20 | 14.81 | 625 | 185 | 4.39 / 972.43 | 6 | 79 |
7 | 8 | 0.16 | 280 | 14.82 | 300 | 1245 | 5.63 / 973.67 | 6 | 132 |
Average= | 16.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 26 | 14.84 | 447 | 172 | 0.17 / 962.70 | 6 | 17 |
2 | 7 | 2002.88 | 40 | 14.57 | 3132 | 1825 | 2.00 / 964.53 | 17 | 55 |
3 | 13 | 1922.84 | 20 | 14.52 | 3032 | 880 | 2.88 / 965.41 | 6 | 60 |
4 | 13 | 1509.64 | 20 | 14.50 | 2485 | 721 | 3.60 / 966.13 | 6 | 68 |
5 | 13 | 856.28 | 20 | 14.61 | 1587 | 464 | 4.06 / 966.59 | 6 | 79 |
6 | 13 | 208.84 | 20 | 14.80 | 638 | 189 | 4.25 / 966.78 | 6 | 78 |
7 | 13 | 40.68 | 20 | 14.85 | 376 | 112 | 4.36 / 966.89 | 6 | 76 |
8 | 8 | -0.16 | 257 | 14.81 | 302 | 1149 | 5.51 / 968.04 | 6 | 133 |
Average= | 16.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 26 | 14.85 | 442 | 171 | 0.17 / 957.27 | 6 | 15 |
2 | 7 | 2005.60 | 40 | 14.57 | 3120 | 1818 | 1.99 / 959.09 | 15 | 57 |
3 | 13 | 1907.40 | 20 | 14.53 | 3027 | 880 | 2.87 / 959.97 | 6 | 59 |
4 | 13 | 1392.60 | 20 | 14.52 | 2318 | 673 | 3.54 / 960.64 | 6 | 71 |
5 | 13 | 871.48 | 20 | 14.60 | 1599 | 467 | 4.01 / 961.11 | 6 | 79 |
6 | 13 | 201.36 | 20 | 14.80 | 628 | 186 | 4.19 / 961.29 | 6 | 78 |
7 | 8 | 0.44 | 278 | 14.82 | 300 | 1236 | 5.43 / 962.53 | 6 | 137 |
Average= | 17.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 27 | 14.85 | 443 | 178 | 0.18 / 951.96 | 6 | 15 |
2 | 7 | 2006.60 | 40 | 14.58 | 3097 | 1806 | 1.98 / 953.76 | 15 | 57 |
3 | 13 | 1919.24 | 20 | 14.54 | 2990 | 869 | 2.85 / 954.63 | 6 | 61 |
4 | 13 | 1402.92 | 20 | 14.53 | 2320 | 674 | 3.53 / 955.31 | 6 | 71 |
5 | 13 | 758.12 | 20 | 14.64 | 1445 | 423 | 3.95 / 955.73 | 6 | 82 |
6 | 13 | 101.52 | 20 | 14.84 | 476 | 141 | 4.09 / 955.87 | 6 | 75 |
7 | 8 | 0.76 | 276 | 14.81 | 301 | 1230 | 5.32 / 957.10 | 6 | 142 |
Average= | 17.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 26 | 14.85 | 437 | 169 | 0.17 / 946.70 | 6 | 15 |
2 | 7 | 2009.56 | 40 | 14.59 | 3087 | 1802 | 1.97 / 948.50 | 11 | 57 |
3 | 13 | 1816.40 | 20 | 14.55 | 2840 | 826 | 2.80 / 949.32 | 6 | 62 |
4 | 13 | 1422.28 | 20 | 14.53 | 2333 | 678 | 3.47 / 950.00 | 6 | 70 |
5 | 13 | 788.04 | 20 | 14.63 | 1478 | 432 | 3.91 / 950.43 | 6 | 79 |
6 | 13 | 74.80 | 20 | 14.85 | 432 | 128 | 4.04 / 950.56 | 6 | 76 |
7 | 8 | -0.92 | 276 | 14.82 | 297 | 1215 | 5.25 / 951.78 | 6 | 139 |
Average= | 17.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 26 | 14.83 | 440 | 170 | 0.17 / 941.21 | 6 | 13 |
2 | 7 | 2004.84 | 40 | 14.58 | 3084 | 1799 | 1.97 / 943.00 | 13 | 56 |
3 | 13 | 1915.40 | 20 | 14.53 | 2998 | 871 | 2.84 / 943.88 | 6 | 62 |
4 | 13 | 1507.36 | 20 | 14.51 | 2450 | 711 | 3.55 / 944.59 | 6 | 71 |
5 | 13 | 1164.56 | 20 | 14.53 | 1974 | 574 | 4.12 / 945.16 | 6 | 76 |
6 | 13 | 87.40 | 20 | 14.85 | 442 | 131 | 4.26 / 945.29 | 6 | 72 |
7 | 13 | 21.88 | 20 | 14.86 | 340 | 101 | 4.36 / 945.39 | 6 | 74 |
8 | 8 | -0.08 | 257 | 14.82 | 298 | 1135 | 5.49 / 946.53 | 6 | 138 |
Average= | 17.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 27 | 14.84 | 429 | 172 | 0.17 / 935.64 | 6 | 14 |
2 | 7 | 2022.12 | 40 | 14.55 | 3151 | 1834 | 2.01 / 937.47 | 14 | 58 |
3 | 13 | 1948.96 | 20 | 14.52 | 3063 | 889 | 2.90 / 938.36 | 6 | 62 |
4 | 13 | 1504.72 | 20 | 14.51 | 2455 | 712 | 3.61 / 939.08 | 6 | 69 |
5 | 13 | 936.92 | 20 | 14.58 | 1685 | 491 | 4.10 / 939.57 | 6 | 79 |
6 | 13 | 272.72 | 20 | 14.78 | 729 | 215 | 4.31 / 939.78 | 6 | 82 |
7 | 13 | 30.16 | 20 | 14.85 | 360 | 107 | 4.42 / 939.89 | 6 | 77 |
8 | 8 | 0.24 | 259 | 14.80 | 299 | 1146 | 5.57 / 941.04 | 6 | 135 |
Average= | 18.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 27 | 14.85 | 444 | 178 | 0.18 / 930.32 | 6 | 13 |
2 | 7 | 2014.16 | 40 | 14.57 | 3118 | 1817 | 2.00 / 932.14 | 13 | 56 |
3 | 13 | 1930.40 | 20 | 14.54 | 2995 | 871 | 2.87 / 933.01 | 6 | 62 |
4 | 13 | 1206.92 | 20 | 14.56 | 2043 | 595 | 3.46 / 933.60 | 6 | 74 |
5 | 13 | 896.04 | 20 | 14.60 | 1632 | 477 | 3.94 / 934.08 | 6 | 80 |
6 | 13 | 54.08 | 20 | 14.85 | 403 | 120 | 4.06 / 934.20 | 6 | 73 |
7 | 13 | 34.40 | 20 | 14.85 | 376 | 112 | 4.17 / 934.31 | 6 | 75 |
8 | 8 | -0.24 | 257 | 14.80 | 304 | 1156 | 5.33 / 935.47 | 6 | 133 |
Average= | 18.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 26 | 14.85 | 439 | 169 | 0.17 / 924.77 | 6 | 11 |
2 | 3 | 1036.60 | 1 | 14.99 | 1830 | 27 | 0.20 / 924.80 | 6 | 34 |
3 | 7 | 2005.28 | 40 | 14.56 | 3135 | 1826 | 2.02 / 926.62 | 34 | 57 |
4 | 13 | 1915.84 | 20 | 14.53 | 3028 | 880 | 2.90 / 927.50 | 6 | 61 |
5 | 13 | 1718.04 | 20 | 14.48 | 2763 | 800 | 3.70 / 928.30 | 6 | 66 |
6 | 13 | 918.92 | 20 | 14.60 | 1643 | 480 | 4.18 / 928.78 | 6 | 80 |
7 | 13 | 149.96 | 20 | 14.82 | 542 | 161 | 4.34 / 928.94 | 6 | 75 |
8 | 13 | 40.48 | 20 | 14.85 | 369 | 110 | 4.45 / 929.05 | 6 | 75 |
9 | 8 | 0.52 | 250 | 14.81 | 295 | 1092 | 5.55 / 930.14 | 6 | 134 |
Average= | 18.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 27 | 14.83 | 446 | 179 | 0.18 / 919.50 | 6 | 12 |
2 | 3 | 953.56 | -1 | 15.29 | 12 | 0 | 0.00 / 919.50 | 6 | 12 |
3 | 7 | 2007.64 | 40 | 14.58 | 3125 | 1822 | 2.00 / 921.32 | 12 | 58 |
4 | 13 | 1918.44 | 20 | 14.54 | 2985 | 868 | 2.87 / 922.19 | 6 | 61 |
5 | 13 | 1186.40 | 20 | 14.58 | 2005 | 585 | 3.45 / 922.77 | 6 | 76 |
6 | 13 | 769.48 | 20 | 14.64 | 1446 | 423 | 3.88 / 923.20 | 6 | 79 |
7 | 13 | 119.64 | 20 | 14.84 | 493 | 146 | 4.02 / 923.34 | 6 | 77 |
8 | 13 | 32.56 | 20 | 14.86 | 362 | 108 | 4.13 / 923.45 | 6 | 74 |
9 | 8 | -0.56 | 259 | 14.81 | 299 | 1147 | 5.28 / 924.60 | 6 | 138 |
Average= | 18.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 26 | 14.85 | 443 | 171 | 0.17 / 913.73 | 6 | 11 |
2 | 3 | 1026.00 | 1 | 14.99 | 1864 | 28 | 0.20 / 913.76 | 6 | 24 |
3 | 7 | 2012.60 | 40 | 14.56 | 3141 | 1829 | 2.03 / 915.59 | 24 | 58 |
4 | 13 | 1925.04 | 20 | 14.53 | 3009 | 874 | 2.90 / 916.46 | 6 | 61 |
5 | 13 | 1715.92 | 20 | 14.47 | 2733 | 791 | 3.69 / 917.25 | 6 | 66 |
6 | 13 | 1175.04 | 20 | 14.51 | 2016 | 585 | 4.28 / 917.84 | 6 | 76 |
7 | 13 | 232.28 | 20 | 14.78 | 683 | 202 | 4.48 / 918.04 | 6 | 79 |
8 | 13 | 31.56 | 20 | 14.85 | 368 | 109 | 4.59 / 918.15 | 6 | 75 |
9 | 8 | 0.04 | 259 | 14.80 | 305 | 1169 | 5.76 / 919.32 | 6 | 130 |
Average= | 19.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 26 | 14.83 | 456 | 176 | 0.18 / 908.42 | 6 | 12 |
2 | 7 | 2002.64 | 40 | 14.57 | 3107 | 1811 | 1.99 / 910.23 | 12 | 58 |
3 | 13 | 1808.44 | 20 | 14.56 | 2860 | 833 | 2.82 / 911.06 | 6 | 66 |
4 | 13 | 1600.08 | 20 | 14.50 | 2576 | 747 | 3.57 / 911.81 | 6 | 70 |
5 | 13 | 719.00 | 20 | 14.65 | 1373 | 402 | 3.97 / 912.21 | 6 | 84 |
6 | 13 | 83.28 | 20 | 14.84 | 441 | 131 | 4.10 / 912.34 | 6 | 73 |
7 | 13 | 21.00 | 20 | 14.85 | 338 | 100 | 4.20 / 912.44 | 6 | 76 |
8 | 8 | -0.16 | 255 | 14.81 | 297 | 1122 | 5.32 / 913.56 | 6 | 131 |
Average= | 19.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 26 | 14.84 | 429 | 166 | 0.17 / 902.99 | 6 | 11 |
2 | 7 | 2002.12 | 40 | 14.57 | 3114 | 1815 | 1.98 / 904.81 | 11 | 58 |
3 | 13 | 1910.96 | 20 | 14.54 | 2996 | 871 | 2.85 / 905.68 | 6 | 61 |
4 | 13 | 1471.12 | 20 | 14.53 | 2417 | 702 | 3.55 / 906.38 | 6 | 72 |
5 | 13 | 822.16 | 20 | 14.62 | 1531 | 448 | 4.00 / 906.83 | 6 | 82 |
6 | 13 | 172.56 | 20 | 14.80 | 580 | 172 | 4.17 / 907.00 | 6 | 79 |
7 | 13 | 19.04 | 20 | 14.85 | 339 | 101 | 4.27 / 907.10 | 6 | 76 |
8 | 8 | 0.44 | 255 | 14.80 | 302 | 1140 | 5.41 / 908.24 | 6 | 134 |
Average= | 19.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 26 | 14.84 | 440 | 170 | 0.17 / 897.59 | 6 | 11 |
2 | 3 | 1019.88 | 1 | 15.01 | 1835 | 28 | 0.20 / 897.62 | 6 | 12 |
3 | 7 | 2010.52 | 41 | 14.58 | 3090 | 1847 | 2.04 / 899.47 | 12 | 57 |
4 | 13 | 1920.72 | 20 | 14.56 | 2980 | 868 | 2.91 / 900.33 | 6 | 62 |
5 | 13 | 1379.56 | 20 | 14.54 | 2277 | 662 | 3.57 / 901.00 | 6 | 73 |
6 | 13 | 840.32 | 20 | 14.62 | 1535 | 449 | 4.02 / 901.45 | 6 | 81 |
7 | 13 | 88.60 | 20 | 14.84 | 455 | 135 | 4.16 / 901.58 | 6 | 75 |
8 | 13 | 25.92 | 20 | 14.85 | 356 | 106 | 4.26 / 901.69 | 6 | 76 |
9 | 8 | -1.32 | 255 | 14.80 | 302 | 1140 | 5.40 / 902.83 | 6 | 138 |
Average= | 20.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 26 | 14.84 | 434 | 167 | 0.17 / 892.10 | 6 | 11 |
2 | 7 | 2041.08 | 40 | 14.58 | 3146 | 1835 | 2.00 / 893.94 | 11 | 56 |
3 | 13 | 1959.80 | 20 | 14.54 | 3033 | 882 | 2.88 / 894.82 | 6 | 61 |
4 | 13 | 1531.24 | 20 | 14.50 | 2503 | 726 | 3.61 / 895.54 | 6 | 70 |
5 | 13 | 875.28 | 20 | 14.60 | 1606 | 469 | 4.08 / 896.01 | 6 | 82 |
6 | 13 | 122.28 | 20 | 14.82 | 500 | 148 | 4.23 / 896.16 | 6 | 77 |
7 | 13 | 32.96 | 20 | 14.84 | 358 | 106 | 4.33 / 896.27 | 6 | 74 |
8 | 8 | 1.00 | 261 | 14.80 | 299 | 1155 | 5.49 / 897.42 | 6 | 132 |
Average= | 20.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 26 | 14.83 | 429 | 165 | 0.17 / 886.66 | 6 | 13 |
2 | 7 | 2014.24 | 40 | 14.57 | 3148 | 1835 | 2.00 / 888.50 | 13 | 58 |
3 | 13 | 1945.28 | 20 | 14.53 | 3035 | 882 | 2.88 / 889.38 | 6 | 62 |
4 | 13 | 1418.88 | 20 | 14.52 | 2336 | 678 | 3.56 / 890.06 | 6 | 73 |
5 | 13 | 871.00 | 20 | 14.60 | 1598 | 467 | 4.03 / 890.52 | 6 | 81 |
6 | 13 | 98.08 | 20 | 14.83 | 472 | 140 | 4.17 / 890.66 | 6 | 77 |
7 | 13 | 24.00 | 20 | 14.85 | 351 | 104 | 4.27 / 890.77 | 6 | 77 |
8 | 8 | -0.68 | 259 | 14.80 | 304 | 1165 | 5.44 / 891.93 | 6 | 134 |
Average= | 20.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 26 | 14.83 | 453 | 175 | 0.17 / 881.19 | 6 | 13 |
2 | 7 | 2006.64 | 40 | 14.59 | 3114 | 1817 | 1.99 / 883.01 | 13 | 57 |
3 | 13 | 1921.56 | 20 | 14.54 | 3013 | 876 | 2.87 / 883.88 | 6 | 63 |
4 | 13 | 1403.28 | 20 | 14.53 | 2335 | 679 | 3.55 / 884.56 | 6 | 72 |
5 | 13 | 960.76 | 20 | 14.59 | 1703 | 497 | 4.04 / 885.06 | 6 | 79 |
6 | 13 | 183.52 | 20 | 14.80 | 605 | 179 | 4.22 / 885.24 | 6 | 81 |
7 | 13 | 20.96 | 20 | 14.85 | 344 | 102 | 4.32 / 885.34 | 6 | 76 |
8 | 8 | -0.52 | 259 | 14.80 | 302 | 1158 | 5.48 / 886.50 | 6 | 132 |
Average= | 21.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 27 | 14.82 | 447 | 179 | 0.18 / 875.67 | 6 | 14 |
2 | 3 | 957.04 | -1 | 15.29 | 12 | 0 | 0.00 / 875.67 | 6 | 14 |
3 | 7 | 2023.08 | 40 | 14.58 | 3146 | 1835 | 2.01 / 877.50 | 14 | 57 |
4 | 13 | 1939.12 | 20 | 14.52 | 3065 | 890 | 2.90 / 878.39 | 6 | 61 |
5 | 13 | 1527.04 | 20 | 14.51 | 2506 | 727 | 3.63 / 879.12 | 6 | 71 |
6 | 13 | 860.52 | 20 | 14.61 | 1579 | 461 | 4.09 / 879.58 | 6 | 83 |
7 | 13 | 117.40 | 20 | 14.82 | 503 | 149 | 4.24 / 879.73 | 6 | 76 |
8 | 13 | 25.36 | 20 | 14.85 | 359 | 107 | 4.35 / 879.84 | 6 | 76 |
9 | 8 | -0.08 | 259 | 14.80 | 307 | 1177 | 5.52 / 881.01 | 6 | 133 |
Average= | 21.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 26 | 14.84 | 447 | 172 | 0.17 / 870.02 | 6 | 11 |
2 | 10 | 1019.32 | 3 | 14.94 | 1767 | 79 | 0.25 / 870.10 | 6 | 52 |
3 | 3 | 960.92 | -1 | 15.29 | 12 | 0 | 0.08 / 870.10 | 6 | 52 |
4 | 7 | 2013.32 | 40 | 14.58 | 3131 | 1826 | 2.08 / 871.92 | 52 | 56 |
5 | 13 | 1930.08 | 20 | 14.56 | 3026 | 881 | 2.96 / 872.80 | 6 | 62 |
6 | 13 | 1625.12 | 20 | 14.51 | 2628 | 763 | 3.72 / 873.57 | 6 | 67 |
7 | 13 | 949.28 | 20 | 14.58 | 1703 | 497 | 4.22 / 874.06 | 6 | 79 |
8 | 13 | 167.48 | 20 | 14.80 | 575 | 170 | 4.39 / 874.23 | 6 | 80 |
9 | 13 | 22.08 | 20 | 14.85 | 340 | 101 | 4.49 / 874.33 | 6 | 74 |
10 | 8 | 0.32 | 261 | 14.80 | 299 | 1155 | 5.64 / 875.49 | 6 | 135 |
Average= | 21.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 26 | 14.82 | 432 | 166 | 0.17 / 864.66 | 6 | 15 |
2 | 7 | 2012.88 | 40 | 14.58 | 3140 | 1831 | 2.00 / 866.49 | 6 | 57 |
3 | 13 | 1818.32 | 20 | 14.55 | 2879 | 838 | 2.84 / 867.33 | 6 | 63 |
4 | 13 | 1305.16 | 20 | 14.55 | 2185 | 636 | 3.47 / 867.96 | 6 | 74 |
5 | 13 | 883.88 | 20 | 14.61 | 1614 | 472 | 3.94 / 868.43 | 6 | 80 |
6 | 13 | 94.52 | 20 | 14.83 | 465 | 138 | 4.08 / 868.57 | 6 | 74 |
7 | 13 | 21.36 | 20 | 14.85 | 349 | 104 | 4.18 / 868.68 | 6 | 76 |
8 | 8 | 0.24 | 259 | 14.80 | 305 | 1169 | 5.35 / 869.85 | 6 | 133 |
Average= | 22.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 26 | 14.81 | 432 | 166 | 0.17 / 859.19 | 6 | 15 |
2 | 7 | 2010.24 | 40 | 14.60 | 3089 | 1804 | 1.97 / 861.00 | 15 | 57 |
3 | 13 | 1912.20 | 20 | 14.56 | 2993 | 872 | 2.84 / 861.87 | 6 | 62 |
4 | 13 | 1399.52 | 20 | 14.55 | 2293 | 667 | 3.51 / 862.54 | 6 | 71 |
5 | 13 | 943.12 | 20 | 14.59 | 1680 | 490 | 4.00 / 863.03 | 6 | 80 |
6 | 13 | 250.36 | 20 | 14.77 | 695 | 205 | 4.20 / 863.23 | 6 | 79 |
7 | 13 | 23.60 | 20 | 14.84 | 349 | 104 | 4.31 / 863.34 | 6 | 74 |
8 | 8 | 0.40 | 259 | 14.79 | 302 | 1157 | 5.47 / 864.49 | 6 | 135 |
Average= | 22.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 27 | 14.83 | 431 | 173 | 0.17 / 853.66 | 6 | 17 |
2 | 3 | 958.40 | -1 | 15.30 | 12 | 0 | 0.00 / 853.66 | 6 | 17 |
3 | 7 | 2012.68 | 40 | 14.59 | 3128 | 1826 | 2.00 / 855.48 | 17 | 57 |
4 | 13 | 1935.72 | 20 | 14.56 | 3027 | 881 | 2.88 / 856.36 | 6 | 60 |
5 | 13 | 1418.20 | 20 | 14.54 | 2336 | 679 | 3.56 / 857.04 | 6 | 70 |
6 | 13 | 973.84 | 20 | 14.58 | 1731 | 505 | 4.06 / 857.55 | 6 | 79 |
7 | 13 | 292.96 | 20 | 14.76 | 755 | 223 | 4.29 / 857.77 | 6 | 81 |
8 | 13 | 34.20 | 20 | 14.83 | 366 | 109 | 4.40 / 857.88 | 6 | 76 |
9 | 8 | -0.76 | 259 | 14.79 | 300 | 1149 | 5.54 / 859.03 | 6 | 130 |
Average= | 23.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 26 | 14.83 | 437 | 168 | 0.17 / 848.25 | 6 | 14 |
2 | 3 | 1032.68 | 1 | 15.00 | 1804 | 27 | 0.20 / 848.28 | 6 | 31 |
3 | 7 | 2000.60 | 40 | 14.59 | 3109 | 1814 | 2.01 / 850.09 | 31 | 56 |
4 | 13 | 1815.68 | 20 | 14.57 | 2868 | 836 | 2.85 / 850.93 | 6 | 61 |
5 | 13 | 1395.72 | 20 | 14.55 | 2313 | 673 | 3.52 / 851.60 | 6 | 74 |
6 | 13 | 764.64 | 20 | 14.63 | 1456 | 426 | 3.94 / 852.02 | 6 | 77 |
7 | 13 | 314.52 | 20 | 14.75 | 779 | 230 | 4.17 / 852.25 | 6 | 80 |
8 | 13 | 36.56 | 20 | 14.83 | 363 | 108 | 4.28 / 852.36 | 6 | 77 |
9 | 8 | 0.56 | 255 | 14.79 | 297 | 1120 | 5.40 / 853.48 | 6 | 131 |
Average= | 23.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 26 | 14.84 | 441 | 170 | 0.17 / 843.00 | 6 | 16 |
2 | 7 | 2006.52 | 40 | 14.60 | 3086 | 1802 | 1.97 / 844.80 | 16 | 57 |
3 | 13 | 1923.60 | 20 | 14.56 | 2975 | 866 | 2.84 / 845.66 | 6 | 61 |
4 | 13 | 1386.76 | 20 | 14.55 | 2282 | 664 | 3.50 / 846.33 | 6 | 72 |
5 | 13 | 655.28 | 20 | 14.67 | 1280 | 376 | 3.88 / 846.70 | 6 | 81 |
6 | 13 | 57.12 | 20 | 14.84 | 406 | 121 | 4.00 / 846.82 | 6 | 74 |
7 | 13 | 33.20 | 20 | 14.85 | 360 | 107 | 4.11 / 846.93 | 6 | 75 |
8 | 8 | 0.12 | 257 | 14.80 | 302 | 1149 | 5.25 / 848.08 | 6 | 132 |
Average= | 24.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 27 | 14.82 | 452 | 181 | 0.18 / 837.65 | 6 | 17 |
2 | 3 | 958.32 | -1 | 15.29 | 12 | 0 | 0.00 / 837.65 | 6 | 17 |
3 | 7 | 2012.16 | 41 | 14.60 | 3098 | 1854 | 2.04 / 839.51 | 17 | 56 |
4 | 13 | 1920.56 | 20 | 14.56 | 2999 | 873 | 2.91 / 840.38 | 6 | 61 |
5 | 13 | 1398.92 | 20 | 14.56 | 2297 | 669 | 3.58 / 841.05 | 6 | 72 |
6 | 13 | 770.44 | 20 | 14.65 | 1437 | 421 | 4.00 / 841.47 | 6 | 83 |
7 | 13 | 60.56 | 20 | 14.85 | 413 | 123 | 4.12 / 841.59 | 6 | 75 |
8 | 8 | -0.72 | 276 | 14.81 | 302 | 1234 | 5.36 / 842.83 | 6 | 137 |
Average= | 24.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 26 | 14.82 | 459 | 177 | 0.18 / 832.30 | 6 | 19 |
2 | 3 | 1038.84 | 1 | 14.98 | 1855 | 28 | 0.20 / 832.33 | 6 | 37 |
3 | 7 | 2005.56 | 40 | 14.60 | 3120 | 1822 | 2.03 / 834.15 | 37 | 57 |
4 | 13 | 1830.84 | 20 | 14.57 | 2892 | 843 | 2.87 / 834.99 | 6 | 64 |
5 | 13 | 1303.24 | 20 | 14.56 | 2201 | 641 | 3.51 / 835.63 | 6 | 74 |
6 | 13 | 777.16 | 20 | 14.64 | 1468 | 430 | 3.94 / 836.06 | 6 | 82 |
7 | 13 | 127.88 | 20 | 14.82 | 524 | 155 | 4.10 / 836.22 | 6 | 77 |
8 | 8 | 0.52 | 272 | 14.80 | 311 | 1252 | 5.35 / 837.47 | 6 | 131 |
Average= | 25.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 26 | 14.81 | 439 | 169 | 0.17 / 826.88 | 6 | 18 |
2 | 7 | 2009.48 | 40 | 14.60 | 3132 | 1829 | 2.00 / 828.71 | 18 | 58 |
3 | 13 | 1934.20 | 20 | 14.55 | 3019 | 879 | 2.88 / 829.59 | 6 | 62 |
4 | 13 | 1408.04 | 20 | 14.54 | 2343 | 681 | 3.56 / 830.27 | 6 | 73 |
5 | 13 | 774.12 | 20 | 14.64 | 1444 | 423 | 3.98 / 830.69 | 6 | 83 |
6 | 13 | 215.12 | 20 | 14.79 | 642 | 190 | 4.17 / 830.88 | 6 | 81 |
7 | 13 | 20.08 | 20 | 14.85 | 339 | 101 | 4.27 / 830.98 | 6 | 78 |
8 | 8 | -0.16 | 255 | 14.80 | 302 | 1140 | 5.41 / 832.12 | 6 | 134 |
Average= | 26.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 27 | 14.83 | 461 | 185 | 0.18 / 821.35 | 6 | 15 |
2 | 7 | 2004.92 | 40 | 14.60 | 3140 | 1834 | 2.02 / 823.19 | 15 | 56 |
3 | 13 | 1919.76 | 20 | 14.56 | 3022 | 880 | 2.90 / 824.07 | 6 | 60 |
4 | 13 | 1481.20 | 20 | 14.54 | 2425 | 705 | 3.60 / 824.77 | 6 | 72 |
5 | 13 | 1029.08 | 20 | 14.58 | 1805 | 526 | 4.13 / 825.30 | 6 | 78 |
6 | 13 | 132.24 | 20 | 14.81 | 520 | 154 | 4.28 / 825.45 | 6 | 76 |
7 | 13 | 11.60 | 20 | 14.84 | 328 | 97 | 4.38 / 825.55 | 6 | 73 |
8 | 8 | 0.08 | 259 | 14.79 | 303 | 1161 | 5.54 / 826.71 | 6 | 133 |
Average= | 26.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 26 | 14.82 | 465 | 179 | 0.18 / 815.90 | 6 | 19 |
2 | 3 | 1035.88 | 1 | 14.98 | 1885 | 28 | 0.21 / 815.93 | 6 | 41 |
3 | 7 | 2019.80 | 40 | 14.59 | 3147 | 1837 | 2.04 / 817.77 | 41 | 58 |
4 | 13 | 1942.96 | 20 | 14.55 | 3045 | 886 | 2.93 / 818.65 | 6 | 61 |
5 | 13 | 1421.36 | 20 | 14.54 | 2358 | 686 | 3.62 / 819.34 | 6 | 72 |
6 | 13 | 778.04 | 20 | 14.64 | 1464 | 429 | 4.04 / 819.77 | 6 | 83 |
7 | 13 | 62.68 | 20 | 14.85 | 419 | 124 | 4.17 / 819.89 | 6 | 73 |
8 | 13 | 14.52 | 20 | 14.86 | 343 | 102 | 4.27 / 819.99 | 6 | 72 |
9 | 8 | -0.12 | 255 | 14.80 | 312 | 1177 | 5.45 / 821.17 | 6 | 131 |
Average= | 27.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 25 | 14.81 | 445 | 165 | 0.16 / 810.31 | 6 | 22 |
2 | 7 | 2006.92 | 40 | 14.59 | 3111 | 1816 | 1.98 / 812.13 | 9 | 58 |
3 | 13 | 1814.52 | 20 | 14.57 | 2878 | 839 | 2.82 / 812.97 | 6 | 65 |
4 | 13 | 1621.84 | 20 | 14.52 | 2603 | 756 | 3.57 / 813.72 | 6 | 71 |
5 | 13 | 941.36 | 20 | 14.60 | 1693 | 494 | 4.07 / 814.22 | 6 | 81 |
6 | 13 | 263.12 | 20 | 14.78 | 724 | 214 | 4.28 / 814.43 | 6 | 81 |
7 | 13 | 30.80 | 20 | 14.85 | 363 | 108 | 4.39 / 814.54 | 6 | 75 |
8 | 8 | 0.44 | 259 | 14.80 | 308 | 1181 | 5.57 / 815.72 | 6 | 129 |
Average= | 28.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 26 | 14.83 | 438 | 169 | 0.17 / 805.01 | 6 | 19 |
2 | 3 | 938.96 | -1 | 15.30 | 12 | 0 | 0.00 / 805.01 | 6 | 19 |
3 | 7 | 2008.32 | 40 | 14.61 | 3084 | 1802 | 1.97 / 806.82 | 19 | 57 |
4 | 13 | 1825.84 | 20 | 14.57 | 2878 | 839 | 2.81 / 807.65 | 6 | 65 |
5 | 13 | 1283.40 | 20 | 14.58 | 2152 | 628 | 3.44 / 808.28 | 6 | 75 |
6 | 13 | 838.60 | 20 | 14.63 | 1527 | 447 | 3.88 / 808.73 | 6 | 79 |
7 | 13 | 147.72 | 20 | 14.81 | 537 | 159 | 4.04 / 808.89 | 6 | 77 |
8 | 13 | 22.96 | 20 | 14.84 | 352 | 104 | 4.15 / 808.99 | 6 | 78 |
9 | 8 | -0.96 | 255 | 14.79 | 307 | 1158 | 5.31 / 810.15 | 6 | 131 |
Average= | 28.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 26 | 14.81 | 464 | 179 | 0.18 / 799.66 | 6 | 20 |
2 | 3 | 1041.68 | 1 | 14.98 | 1849 | 28 | 0.21 / 799.68 | 6 | 39 |
3 | 7 | 2003.80 | 40 | 14.61 | 3101 | 1812 | 2.02 / 801.50 | 39 | 59 |
4 | 13 | 1906.52 | 20 | 14.56 | 2997 | 873 | 2.89 / 802.37 | 6 | 61 |
5 | 13 | 1462.68 | 20 | 14.55 | 2400 | 698 | 3.59 / 803.07 | 6 | 72 |
6 | 13 | 697.68 | 20 | 14.67 | 1357 | 398 | 3.99 / 803.46 | 6 | 82 |
7 | 13 | 45.56 | 20 | 14.86 | 387 | 115 | 4.10 / 803.58 | 6 | 75 |
8 | 8 | -0.32 | 279 | 14.81 | 306 | 1264 | 5.37 / 804.84 | 6 | 132 |
Average= | 29.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 25 | 14.80 | 449 | 166 | 0.17 / 794.00 | 6 | 19 |
2 | 3 | 1025.12 | 1 | 15.01 | 1845 | 28 | 0.19 / 794.03 | 6 | 23 |
3 | 7 | 2016.52 | 40 | 14.59 | 3139 | 1832 | 2.03 / 795.86 | 23 | 58 |
4 | 13 | 1934.04 | 20 | 14.57 | 3019 | 880 | 2.91 / 796.74 | 6 | 62 |
5 | 13 | 1446.12 | 20 | 14.56 | 2384 | 694 | 3.60 / 797.43 | 6 | 73 |
6 | 13 | 1093.88 | 20 | 14.57 | 1884 | 549 | 4.15 / 797.98 | 6 | 79 |
7 | 13 | 368.00 | 20 | 14.74 | 870 | 256 | 4.41 / 798.24 | 6 | 83 |
8 | 8 | -0.24 | 272 | 14.79 | 308 | 1239 | 5.64 / 799.48 | 6 | 139 |
Average= | 30.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 25 | 14.81 | 460 | 170 | 0.17 / 788.17 | 6 | 22 |
2 | 7 | 2021.28 | 40 | 14.60 | 3136 | 1831 | 2.00 / 790.00 | 22 | 58 |
3 | 13 | 1922.68 | 20 | 14.56 | 3034 | 884 | 2.89 / 790.89 | 6 | 63 |
4 | 13 | 1609.16 | 20 | 14.52 | 2619 | 761 | 3.65 / 791.65 | 6 | 70 |
5 | 13 | 1257.36 | 20 | 14.52 | 2152 | 625 | 4.27 / 792.27 | 6 | 77 |
6 | 13 | 331.40 | 20 | 14.75 | 833 | 246 | 4.52 / 792.52 | 6 | 83 |
7 | 13 | 38.16 | 20 | 14.83 | 385 | 114 | 4.63 / 792.63 | 6 | 78 |
8 | 8 | -0.52 | 259 | 14.78 | 314 | 1202 | 5.83 / 793.83 | 6 | 130 |
Average= | 31.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 27 | 14.82 | 451 | 180 | 0.18 / 782.65 | 6 | 22 |
2 | 3 | 911.68 | -1 | 15.30 | 12 | 0 | 0.00 / 782.65 | 6 | 22 |
3 | 7 | 2022.40 | 40 | 14.60 | 3158 | 1844 | 2.02 / 784.50 | 22 | 59 |
4 | 13 | 1934.60 | 20 | 14.56 | 3048 | 888 | 2.91 / 785.38 | 6 | 61 |
5 | 13 | 1500.12 | 20 | 14.54 | 2460 | 715 | 3.63 / 786.10 | 6 | 71 |
6 | 13 | 947.40 | 20 | 14.60 | 1696 | 495 | 4.12 / 786.59 | 6 | 77 |
7 | 13 | 97.60 | 20 | 14.83 | 463 | 137 | 4.26 / 786.73 | 6 | 73 |
8 | 8 | 0.00 | 281 | 14.80 | 305 | 1268 | 5.53 / 788.00 | 6 | 135 |
Average= | 32.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 25 | 14.82 | 452 | 167 | 0.17 / 777.36 | 6 | 21 |
2 | 10 | 1011.84 | 3 | 14.92 | 1814 | 81 | 0.25 / 777.44 | 6 | 55 |
3 | 7 | 2005.88 | 40 | 14.61 | 3086 | 1803 | 2.05 / 779.24 | 55 | 58 |
4 | 13 | 1914.88 | 20 | 14.58 | 2974 | 867 | 2.92 / 780.11 | 6 | 62 |
5 | 13 | 1284.92 | 20 | 14.59 | 2137 | 624 | 3.54 / 780.74 | 6 | 74 |
6 | 13 | 650.16 | 20 | 14.68 | 1275 | 374 | 3.92 / 781.11 | 6 | 83 |
7 | 13 | 106.80 | 20 | 14.83 | 479 | 142 | 4.06 / 781.25 | 6 | 76 |
8 | 8 | -0.08 | 270 | 14.81 | 305 | 1220 | 5.28 / 782.47 | 6 | 132 |
Average= | 34.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 26 | 14.82 | 448 | 173 | 0.17 / 771.84 | 6 | 20 |
2 | 7 | 2012.20 | 40 | 14.62 | 3096 | 1811 | 1.98 / 773.65 | 20 | 58 |
3 | 13 | 1919.48 | 20 | 14.58 | 2987 | 871 | 2.85 / 774.52 | 6 | 62 |
4 | 13 | 1499.52 | 20 | 14.55 | 2454 | 714 | 3.57 / 775.23 | 6 | 70 |
5 | 13 | 925.68 | 20 | 14.61 | 1679 | 491 | 4.06 / 775.72 | 6 | 82 |
6 | 13 | 233.56 | 20 | 14.78 | 679 | 201 | 4.26 / 775.92 | 6 | 82 |
7 | 8 | -0.56 | 280 | 14.79 | 306 | 1267 | 5.53 / 777.19 | 6 | 143 |
Average= | 35.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 27 | 14.83 | 446 | 179 | 0.18 / 766.38 | 6 | 22 |
2 | 3 | 967.60 | -1 | 15.31 | 12 | 0 | 0.00 / 766.38 | 6 | 22 |
3 | 7 | 2009.36 | 40 | 14.60 | 3154 | 1842 | 2.02 / 768.23 | 22 | 58 |
4 | 13 | 1935.00 | 20 | 14.56 | 3025 | 881 | 2.90 / 769.11 | 6 | 62 |
5 | 13 | 1502.12 | 20 | 14.54 | 2462 | 716 | 3.62 / 769.82 | 6 | 72 |
6 | 13 | 828.96 | 20 | 14.63 | 1533 | 449 | 4.07 / 770.27 | 6 | 80 |
7 | 13 | 86.08 | 20 | 14.84 | 460 | 137 | 4.20 / 770.41 | 6 | 74 |
8 | 8 | 0.04 | 276 | 14.80 | 308 | 1258 | 5.46 / 771.67 | 6 | 130 |
Average= | 36.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 26 | 14.81 | 455 | 175 | 0.18 / 760.84 | 6 | 16 |
2 | 3 | 1039.96 | 1 | 15.00 | 1823 | 27 | 0.20 / 760.87 | 6 | 34 |
3 | 7 | 2012.20 | 40 | 14.60 | 3160 | 1845 | 2.05 / 762.71 | 34 | 58 |
4 | 13 | 1940.72 | 20 | 14.55 | 3073 | 894 | 2.94 / 763.61 | 6 | 63 |
5 | 13 | 1410.08 | 20 | 14.55 | 2366 | 689 | 3.63 / 764.29 | 6 | 73 |
6 | 13 | 864.00 | 20 | 14.62 | 1599 | 468 | 4.10 / 764.76 | 6 | 78 |
7 | 13 | 199.68 | 20 | 14.80 | 634 | 188 | 4.29 / 764.95 | 6 | 77 |
8 | 13 | 42.72 | 20 | 14.85 | 380 | 113 | 4.40 / 765.06 | 6 | 74 |
9 | 8 | 0.00 | 253 | 14.80 | 305 | 1142 | 5.54 / 766.20 | 6 | 132 |
Average= | 38.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 27 | 14.82 | 458 | 183 | 0.18 / 755.30 | 6 | 19 |
2 | 3 | 953.76 | -1 | 15.31 | 12 | 0 | 0.00 / 755.30 | 6 | 19 |
3 | 7 | 2003.44 | 40 | 14.60 | 3122 | 1823 | 2.01 / 757.13 | 19 | 58 |
4 | 13 | 1915.72 | 20 | 14.57 | 3017 | 879 | 2.89 / 758.01 | 6 | 62 |
5 | 13 | 1375.12 | 20 | 14.57 | 2297 | 669 | 3.56 / 758.68 | 6 | 73 |
6 | 13 | 836.20 | 20 | 14.64 | 1537 | 450 | 4.01 / 759.13 | 6 | 78 |
7 | 13 | 375.12 | 20 | 14.74 | 884 | 261 | 4.27 / 759.39 | 6 | 84 |
8 | 13 | 21.76 | 20 | 14.83 | 353 | 105 | 4.37 / 759.49 | 6 | 77 |
9 | 8 | 0.36 | 259 | 14.79 | 306 | 1172 | 5.54 / 760.66 | 6 | 135 |
Average= | 40.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 27 | 14.82 | 438 | 175 | 0.18 / 749.91 | 6 | 21 |
2 | 7 | 2015.00 | 40 | 14.60 | 3121 | 1823 | 2.00 / 751.73 | 21 | 59 |
3 | 13 | 1947.60 | 20 | 14.57 | 3041 | 886 | 2.88 / 752.62 | 6 | 63 |
4 | 13 | 1508.56 | 20 | 14.56 | 2447 | 713 | 3.60 / 753.33 | 6 | 73 |
5 | 13 | 739.20 | 20 | 14.66 | 1413 | 414 | 4.01 / 753.75 | 6 | 82 |
6 | 13 | 80.52 | 20 | 14.85 | 440 | 131 | 4.14 / 753.88 | 6 | 74 |
7 | 13 | 17.88 | 20 | 14.86 | 340 | 101 | 4.24 / 753.98 | 6 | 74 |
8 | 8 | 0.48 | 251 | 14.80 | 308 | 1144 | 5.39 / 755.12 | 6 | 135 |
Average= | 41.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 27 | 14.81 | 448 | 179 | 0.18 / 744.39 | 6 | 19 |
2 | 7 | 2007.00 | 41 | 14.61 | 3134 | 1877 | 2.06 / 746.27 | 19 | 57 |
3 | 13 | 1930.72 | 20 | 14.57 | 3038 | 885 | 2.94 / 747.15 | 6 | 61 |
4 | 13 | 1195.32 | 20 | 14.60 | 2027 | 592 | 3.53 / 747.74 | 6 | 75 |
5 | 13 | 997.36 | 20 | 14.59 | 1774 | 518 | 4.05 / 748.26 | 6 | 78 |
6 | 13 | 300.08 | 20 | 14.76 | 769 | 227 | 4.28 / 748.49 | 6 | 82 |
7 | 8 | -0.88 | 278 | 14.79 | 303 | 1246 | 5.52 / 749.73 | 6 | 130 |
Average= | 44.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 27 | 14.81 | 454 | 182 | 0.18 / 738.86 | 6 | 19 |
2 | 7 | 2012.52 | 41 | 14.60 | 3137 | 1878 | 2.06 / 740.73 | 19 | 54 |
3 | 13 | 1930.16 | 20 | 14.56 | 3048 | 888 | 2.95 / 741.62 | 6 | 64 |
4 | 13 | 1393.24 | 20 | 14.56 | 2311 | 673 | 3.62 / 742.30 | 6 | 73 |
5 | 13 | 850.36 | 20 | 14.63 | 1566 | 458 | 4.08 / 742.75 | 6 | 81 |
6 | 13 | 265.44 | 20 | 14.78 | 729 | 215 | 4.29 / 742.97 | 6 | 80 |
7 | 8 | 0.16 | 276 | 14.80 | 304 | 1242 | 5.54 / 744.21 | 6 | 140 |
Average= | 46.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 26 | 14.83 | 440 | 170 | 0.17 / 733.42 | 6 | 16 |
2 | 3 | 1028.04 | 1 | 15.02 | 1838 | 28 | 0.20 / 733.44 | 6 | 22 |
3 | 7 | 2017.60 | 40 | 14.62 | 3106 | 1816 | 2.01 / 735.26 | 22 | 58 |
4 | 13 | 1933.96 | 20 | 14.58 | 3022 | 881 | 2.89 / 736.14 | 6 | 61 |
5 | 13 | 1370.68 | 20 | 14.58 | 2278 | 664 | 3.56 / 736.81 | 6 | 74 |
6 | 13 | 838.96 | 20 | 14.64 | 1547 | 453 | 4.01 / 737.26 | 6 | 81 |
7 | 13 | 158.24 | 20 | 14.81 | 543 | 161 | 4.17 / 737.42 | 6 | 75 |
8 | 13 | 21.76 | 20 | 14.85 | 341 | 101 | 4.27 / 737.52 | 6 | 73 |
9 | 8 | 0.64 | 261 | 14.80 | 299 | 1155 | 5.43 / 738.68 | 6 | 145 |
Average= | 49.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 27 | 14.82 | 454 | 182 | 0.18 / 727.81 | 6 | 18 |
2 | 3 | 950.20 | -1 | 15.31 | 12 | 0 | 0.00 / 727.81 | 6 | 18 |
3 | 7 | 2014.80 | 40 | 14.60 | 3185 | 1860 | 2.04 / 729.67 | 18 | 58 |
4 | 13 | 1946.28 | 20 | 14.57 | 3057 | 891 | 2.93 / 730.56 | 6 | 62 |
5 | 13 | 1639.48 | 20 | 14.52 | 2658 | 772 | 3.70 / 731.33 | 6 | 69 |
6 | 13 | 950.24 | 20 | 14.60 | 1735 | 507 | 4.21 / 731.84 | 6 | 79 |
7 | 13 | 170.80 | 20 | 14.81 | 585 | 173 | 4.38 / 732.01 | 6 | 77 |
8 | 8 | 0.40 | 278 | 14.80 | 300 | 1234 | 5.62 / 733.25 | 6 | 132 |
Average= | 52.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 25 | 14.84 | 449 | 167 | 0.17 / 722.36 | 6 | 13 |
2 | 3 | 1072.72 | 2 | 14.99 | 1895 | 57 | 0.22 / 722.41 | 6 | 53 |
3 | 7 | 2017.60 | 40 | 14.61 | 3128 | 1828 | 2.05 / 724.24 | 53 | 59 |
4 | 13 | 1944.00 | 20 | 14.56 | 3048 | 888 | 2.94 / 725.13 | 6 | 62 |
5 | 13 | 1394.92 | 20 | 14.57 | 2323 | 677 | 3.62 / 725.81 | 6 | 74 |
6 | 13 | 844.32 | 20 | 14.64 | 1543 | 452 | 4.07 / 726.26 | 6 | 82 |
7 | 13 | 61.04 | 20 | 14.85 | 412 | 122 | 4.19 / 726.38 | 6 | 73 |
8 | 13 | 15.28 | 20 | 14.86 | 332 | 99 | 4.29 / 726.48 | 6 | 73 |
9 | 8 | -0.40 | 257 | 14.80 | 302 | 1149 | 5.44 / 727.63 | 6 | 135 |
Average= | 55.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 26 | 14.82 | 439 | 169 | 0.17 / 716.94 | 6 | 14 |
2 | 7 | 2006.88 | 40 | 14.62 | 3116 | 1822 | 1.99 / 718.76 | 14 | 57 |
3 | 13 | 1934.56 | 20 | 14.57 | 3035 | 884 | 2.88 / 719.65 | 6 | 62 |
4 | 13 | 1402.08 | 20 | 14.58 | 2341 | 683 | 3.56 / 720.33 | 6 | 74 |
5 | 13 | 845.04 | 20 | 14.64 | 1558 | 456 | 4.01 / 720.79 | 6 | 80 |
6 | 13 | 91.20 | 20 | 14.85 | 464 | 138 | 4.15 / 720.92 | 6 | 77 |
7 | 13 | 20.80 | 20 | 14.86 | 352 | 105 | 4.26 / 721.03 | 6 | 75 |
8 | 8 | -0.08 | 257 | 14.81 | 305 | 1161 | 5.42 / 722.19 | 6 | 132 |
Average= | 60.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 26 | 14.81 | 430 | 166 | 0.17 / 711.38 | 6 | 15 |
2 | 7 | 2013.48 | 40 | 14.61 | 3147 | 1839 | 2.00 / 713.22 | 15 | 59 |
3 | 13 | 1946.32 | 20 | 14.58 | 3036 | 885 | 2.89 / 714.11 | 6 | 62 |
4 | 13 | 1407.88 | 20 | 14.58 | 2327 | 679 | 3.57 / 714.79 | 6 | 73 |
5 | 13 | 1078.72 | 20 | 14.58 | 1864 | 544 | 4.11 / 715.33 | 6 | 78 |
6 | 13 | 136.12 | 20 | 14.82 | 532 | 158 | 4.27 / 715.49 | 6 | 79 |
7 | 13 | 28.32 | 20 | 14.84 | 359 | 107 | 4.38 / 715.59 | 6 | 75 |
8 | 8 | 0.36 | 261 | 14.79 | 305 | 1177 | 5.55 / 716.77 | 6 | 136 |
Average= | 65.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 26 | 14.84 | 442 | 171 | 0.17 / 705.76 | 6 | 16 |
2 | 7 | 2010.08 | 40 | 14.61 | 3158 | 1846 | 2.02 / 707.61 | 16 | 60 |
3 | 13 | 1933.16 | 20 | 14.58 | 3057 | 891 | 2.91 / 708.50 | 6 | 62 |
4 | 13 | 1424.56 | 20 | 14.56 | 2357 | 686 | 3.59 / 709.19 | 6 | 75 |
5 | 13 | 887.68 | 20 | 14.63 | 1606 | 470 | 4.06 / 709.66 | 6 | 81 |
6 | 13 | 413.20 | 20 | 14.73 | 930 | 274 | 4.34 / 709.93 | 6 | 83 |
7 | 13 | 32.72 | 20 | 14.83 | 372 | 110 | 4.45 / 710.04 | 6 | 78 |
8 | 8 | 0.08 | 259 | 14.78 | 308 | 1179 | 5.63 / 711.22 | 6 | 131 |
Average= | 71.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 26 | 14.83 | 436 | 168 | 0.17 / 700.37 | 6 | 13 |
2 | 7 | 2014.16 | 40 | 14.61 | 3129 | 1829 | 2.00 / 702.20 | 13 | 58 |
3 | 13 | 1929.00 | 20 | 14.58 | 3023 | 882 | 2.88 / 703.08 | 6 | 64 |
4 | 13 | 1513.88 | 20 | 14.56 | 2469 | 719 | 3.60 / 703.80 | 6 | 71 |
5 | 13 | 759.24 | 20 | 14.66 | 1440 | 422 | 4.02 / 704.22 | 6 | 82 |
6 | 13 | 112.96 | 20 | 14.84 | 498 | 148 | 4.17 / 704.37 | 6 | 76 |
7 | 13 | 30.28 | 20 | 14.86 | 355 | 106 | 4.27 / 704.47 | 6 | 73 |
8 | 8 | -0.92 | 253 | 14.82 | 298 | 1117 | 5.39 / 705.59 | 6 | 132 |
Average= | 78.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 26 | 14.82 | 442 | 170 | 0.17 / 694.79 | 6 | 14 |
2 | 7 | 2017.88 | 40 | 14.62 | 3152 | 1843 | 2.01 / 696.63 | 14 | 58 |
3 | 13 | 1936.48 | 20 | 14.58 | 3059 | 892 | 2.91 / 697.52 | 6 | 61 |
4 | 13 | 1505.04 | 20 | 14.55 | 2476 | 721 | 3.63 / 698.25 | 6 | 72 |
5 | 13 | 853.28 | 20 | 14.63 | 1570 | 459 | 4.09 / 698.70 | 6 | 83 |
6 | 13 | 283.92 | 20 | 14.78 | 752 | 222 | 4.31 / 698.93 | 6 | 83 |
7 | 13 | 34.68 | 20 | 14.85 | 367 | 109 | 4.42 / 699.04 | 6 | 76 |
8 | 8 | 1.04 | 259 | 14.80 | 304 | 1165 | 5.58 / 700.20 | 6 | 132 |
Average= | 87.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 26 | 14.84 | 434 | 167 | 0.17 / 689.38 | 6 | 11 |
2 | 7 | 2005.36 | 40 | 14.63 | 3108 | 1819 | 1.99 / 691.20 | 11 | 59 |
3 | 13 | 1911.04 | 20 | 14.58 | 3020 | 881 | 2.87 / 692.08 | 6 | 64 |
4 | 13 | 1389.60 | 20 | 14.57 | 2311 | 673 | 3.54 / 692.75 | 6 | 74 |
5 | 13 | 750.72 | 20 | 14.67 | 1424 | 418 | 3.96 / 693.17 | 6 | 81 |
6 | 13 | 303.32 | 20 | 14.77 | 773 | 228 | 4.19 / 693.40 | 6 | 83 |
7 | 13 | 36.92 | 20 | 14.85 | 368 | 109 | 4.30 / 693.51 | 6 | 76 |
8 | 8 | 0.40 | 250 | 14.80 | 300 | 1110 | 5.41 / 694.62 | 6 | 129 |
Average= | 99.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 25 | 14.84 | 436 | 162 | 0.16 / 683.82 | 6 | 12 |
2 | 3 | 1035.76 | 1 | 15.01 | 1868 | 28 | 0.19 / 683.85 | 6 | 36 |
3 | 7 | 2005.16 | 40 | 14.64 | 3069 | 1797 | 1.99 / 685.65 | 36 | 59 |
4 | 13 | 1908.76 | 20 | 14.60 | 2962 | 865 | 2.85 / 686.51 | 6 | 64 |
5 | 13 | 1584.76 | 20 | 14.56 | 2562 | 746 | 3.60 / 687.26 | 6 | 71 |
6 | 13 | 1108.20 | 20 | 14.58 | 1918 | 559 | 4.16 / 687.82 | 6 | 80 |
7 | 13 | 93.40 | 20 | 14.85 | 457 | 136 | 4.29 / 687.96 | 6 | 76 |
8 | 13 | 20.88 | 20 | 14.86 | 345 | 103 | 4.40 / 688.06 | 6 | 73 |
9 | 8 | -0.24 | 259 | 14.82 | 301 | 1155 | 5.55 / 689.21 | 6 | 137 |
Average= | 114.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 26 | 14.85 | 419 | 162 | 0.16 / 678.57 | 6 | 16 |
2 | 7 | 2001.96 | 40 | 14.64 | 3083 | 1805 | 1.97 / 680.37 | 16 | 59 |
3 | 13 | 1816.28 | 20 | 14.61 | 2874 | 840 | 2.81 / 681.21 | 6 | 64 |
4 | 13 | 1306.56 | 20 | 14.60 | 2183 | 637 | 3.44 / 681.85 | 6 | 76 |
5 | 13 | 797.36 | 20 | 14.66 | 1474 | 432 | 3.88 / 682.28 | 6 | 81 |
6 | 13 | 122.48 | 20 | 14.84 | 505 | 150 | 4.03 / 682.43 | 6 | 74 |
7 | 13 | 22.48 | 20 | 14.86 | 342 | 102 | 4.13 / 682.53 | 6 | 76 |
8 | 8 | 0.44 | 255 | 14.81 | 299 | 1129 | 5.26 / 683.66 | 6 | 139 |
Average= | 136.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 25 | 14.83 | 434 | 161 | 0.16 / 673.13 | 6 | 14 |
2 | 3 | 1024.44 | 1 | 15.04 | 1810 | 27 | 0.19 / 673.15 | 6 | 16 |
3 | 7 | 2073.76 | 40 | 14.59 | 3217 | 1877 | 2.07 / 675.03 | 16 | 59 |
4 | 13 | 1990.20 | 20 | 14.57 | 3082 | 898 | 2.96 / 675.93 | 6 | 65 |
5 | 13 | 1366.12 | 20 | 14.56 | 2279 | 664 | 3.63 / 676.59 | 6 | 74 |
6 | 13 | 828.88 | 20 | 14.64 | 1529 | 448 | 4.07 / 677.04 | 6 | 83 |
7 | 13 | 87.04 | 20 | 14.85 | 439 | 130 | 4.21 / 677.17 | 6 | 74 |
8 | 13 | 25.08 | 20 | 14.87 | 340 | 101 | 4.31 / 677.27 | 6 | 74 |
9 | 8 | -0.16 | 259 | 14.82 | 295 | 1132 | 5.44 / 678.41 | 6 | 134 |
Average= | 169.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 25 | 14.84 | 436 | 162 | 0.16 / 667.87 | 6 | 15 |
2 | 7 | 2023.20 | 41 | 14.62 | 3127 | 1874 | 2.04 / 669.74 | 15 | 58 |
3 | 13 | 1927.48 | 20 | 14.57 | 3032 | 884 | 2.92 / 670.63 | 6 | 61 |
4 | 13 | 1194.44 | 20 | 14.61 | 2037 | 595 | 3.51 / 671.22 | 6 | 77 |
5 | 13 | 672.76 | 20 | 14.69 | 1309 | 385 | 3.90 / 671.61 | 6 | 84 |
6 | 13 | 126.12 | 20 | 14.84 | 500 | 148 | 4.05 / 671.76 | 6 | 73 |
7 | 8 | 0.44 | 276 | 14.82 | 296 | 1211 | 5.26 / 672.97 | 6 | 132 |
Average= | 224.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 25 | 14.83 | 448 | 166 | 0.17 / 662.54 | 6 | 20 |
2 | 7 | 2007.48 | 40 | 14.62 | 3131 | 1831 | 2.00 / 664.37 | 20 | 58 |
3 | 13 | 1922.56 | 20 | 14.59 | 3029 | 884 | 2.88 / 665.25 | 6 | 64 |
4 | 13 | 1394.72 | 20 | 14.59 | 2319 | 677 | 3.56 / 665.93 | 6 | 76 |
5 | 13 | 747.04 | 20 | 14.67 | 1420 | 417 | 3.97 / 666.34 | 6 | 83 |
6 | 13 | 65.12 | 20 | 14.87 | 417 | 124 | 4.10 / 666.47 | 6 | 74 |
7 | 8 | 0.08 | 276 | 14.83 | 303 | 1240 | 5.34 / 667.71 | 6 | 135 |
Average= | 333.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 27 | 14.84 | 437 | 175 | 0.18 / 657.17 | 6 | 16 |
2 | 3 | 944.76 | -1 | 15.33 | 12 | 0 | 0.00 / 657.17 | 6 | 16 |
3 | 7 | 2009.96 | 41 | 14.61 | 3153 | 1889 | 2.06 / 659.06 | 16 | 59 |
4 | 13 | 1919.88 | 20 | 14.59 | 3015 | 880 | 2.94 / 659.94 | 6 | 64 |
5 | 13 | 1397.56 | 20 | 14.58 | 2305 | 672 | 3.62 / 660.61 | 6 | 74 |
6 | 13 | 836.08 | 20 | 14.66 | 1529 | 448 | 4.06 / 661.06 | 6 | 83 |
7 | 13 | 172.20 | 20 | 14.82 | 572 | 170 | 4.23 / 661.23 | 6 | 76 |
8 | 8 | -0.72 | 257 | 14.82 | 300 | 1143 | 5.38 / 662.37 | 6 | 129 |
Average= | 662.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 25 | 14.84 | 439 | 163 | 0.16 / 651.60 | 6 | 18 |
2 | 3 | 1020.44 | 1 | 15.06 | 1810 | 27 | 0.19 / 651.63 | 6 | 20 |
3 | 7 | 2014.48 | 41 | 14.64 | 3093 | 1857 | 2.05 / 653.49 | 20 | 60 |
4 | 13 | 1918.68 | 20 | 14.61 | 2986 | 873 | 2.92 / 654.36 | 6 | 61 |
5 | 13 | 1706.76 | 20 | 14.55 | 2731 | 795 | 3.71 / 655.15 | 6 | 68 |
6 | 13 | 913.84 | 20 | 14.64 | 1638 | 480 | 4.19 / 655.63 | 6 | 81 |
7 | 13 | 74.44 | 20 | 14.87 | 430 | 128 | 4.32 / 655.76 | 6 | 73 |
8 | 8 | -0.12 | 274 | 14.83 | 303 | 1231 | 5.55 / 656.99 | 6 | 135 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 26 | 14.85 | 439 | 169 | 0.17 / 646.20 | 6 | 19 |
2 | 7 | 2012.24 | 40 | 14.64 | 3091 | 1810 | 1.98 / 648.01 | 19 | 58 |
3 | 13 | 1918.52 | 20 | 14.61 | 2972 | 868 | 2.85 / 648.88 | 6 | 63 |
4 | 13 | 1395.12 | 20 | 14.59 | 2300 | 671 | 3.52 / 649.55 | 6 | 73 |
5 | 13 | 855.72 | 20 | 14.65 | 1569 | 460 | 3.98 / 650.01 | 6 | 83 |
6 | 13 | 287.48 | 20 | 14.79 | 748 | 221 | 4.20 / 650.23 | 6 | 82 |
7 | 8 | 0.08 | 274 | 14.82 | 297 | 1206 | 5.41 / 651.44 | 6 | 135 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 26 | 14.83 | 457 | 176 | 0.18 / 640.92 | 6 | 19 |
2 | 7 | 2004.12 | 41 | 14.65 | 3079 | 1849 | 2.03 / 642.77 | 19 | 58 |
3 | 13 | 1914.72 | 20 | 14.61 | 2985 | 872 | 2.90 / 643.64 | 6 | 65 |
4 | 13 | 1187.56 | 20 | 14.64 | 2016 | 590 | 3.49 / 644.23 | 6 | 76 |
5 | 13 | 849.92 | 20 | 14.66 | 1565 | 459 | 3.95 / 644.69 | 6 | 83 |
6 | 13 | 40.04 | 20 | 14.88 | 378 | 112 | 4.06 / 644.80 | 6 | 73 |
7 | 8 | 0.48 | 274 | 14.83 | 303 | 1231 | 5.29 / 646.03 | 6 | 135 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 25 | 14.85 | 440 | 163 | 0.16 / 635.42 | 6 | 16 |
2 | 7 | 2008.84 | 41 | 14.64 | 3114 | 1869 | 2.03 / 637.29 | 16 | 60 |
3 | 13 | 1927.60 | 20 | 14.59 | 3019 | 881 | 2.91 / 638.17 | 6 | 63 |
4 | 13 | 1390.48 | 20 | 14.59 | 2302 | 672 | 3.59 / 638.85 | 6 | 73 |
5 | 13 | 860.36 | 20 | 14.66 | 1560 | 457 | 4.04 / 639.30 | 6 | 81 |
6 | 13 | 389.64 | 20 | 14.76 | 903 | 267 | 4.31 / 639.57 | 6 | 85 |
7 | 8 | -0.04 | 263 | 14.82 | 301 | 1173 | 5.48 / 640.74 | 6 | 132 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 25 | 14.86 | 444 | 165 | 0.16 / 629.99 | 6 | 18 |
2 | 7 | 1998.56 | 40 | 14.64 | 3132 | 1834 | 2.00 / 631.83 | 18 | 59 |
3 | 13 | 1933.36 | 20 | 14.60 | 3033 | 886 | 2.88 / 632.71 | 6 | 62 |
4 | 13 | 1507.24 | 20 | 14.58 | 2479 | 723 | 3.61 / 633.43 | 6 | 73 |
5 | 13 | 949.72 | 20 | 14.63 | 1692 | 495 | 4.10 / 633.93 | 6 | 80 |
6 | 13 | 80.16 | 20 | 14.87 | 435 | 129 | 4.23 / 634.06 | 6 | 75 |
7 | 8 | -0.44 | 272 | 14.84 | 298 | 1203 | 5.43 / 635.26 | 6 | 130 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 26 | 14.81 | 461 | 178 | 0.18 / 624.64 | 6 | 22 |
2 | 3 | 963.04 | -1 | 15.32 | 12 | 0 | 0.00 / 624.64 | 6 | 22 |
3 | 7 | 2018.84 | 40 | 14.64 | 3134 | 1835 | 2.01 / 626.47 | 22 | 57 |
4 | 13 | 1960.28 | 20 | 14.61 | 3047 | 890 | 2.90 / 627.36 | 6 | 63 |
5 | 13 | 1408.08 | 20 | 14.60 | 2328 | 680 | 3.58 / 628.04 | 6 | 74 |
6 | 13 | 753.16 | 20 | 14.69 | 1426 | 419 | 4.00 / 628.46 | 6 | 83 |
7 | 13 | 92.56 | 20 | 14.88 | 464 | 138 | 4.14 / 628.60 | 6 | 76 |
8 | 8 | 0.72 | 274 | 14.85 | 302 | 1229 | 5.37 / 629.83 | 6 | 133 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 24 | 14.86 | 454 | 162 | 0.16 / 618.47 | 6 | 19 |
2 | 3 | 1071.24 | 2 | 14.99 | 1908 | 57 | 0.22 / 618.53 | 6 | 56 |
3 | 7 | 2008.44 | 40 | 14.62 | 3152 | 1843 | 2.06 / 620.37 | 56 | 57 |
4 | 13 | 1933.44 | 20 | 14.59 | 3033 | 885 | 2.95 / 621.26 | 6 | 63 |
5 | 13 | 1716.20 | 20 | 14.55 | 2746 | 799 | 3.75 / 622.06 | 6 | 67 |
6 | 13 | 1261.72 | 20 | 14.57 | 2127 | 620 | 4.37 / 622.68 | 6 | 77 |
7 | 13 | 861.32 | 20 | 14.61 | 1581 | 462 | 4.83 / 623.14 | 6 | 84 |
8 | 13 | 30.40 | 20 | 14.85 | 374 | 111 | 4.94 / 623.25 | 6 | 77 |
9 | 8 | -0.40 | 259 | 14.80 | 315 | 1207 | 6.15 / 624.46 | 6 | 132 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 25 | 14.84 | 447 | 166 | 0.17 / 613.15 | 6 | 20 |
2 | 3 | 964.52 | -1 | 15.33 | 12 | 0 | 0.00 / 613.15 | 6 | 20 |
3 | 7 | 2018.32 | 40 | 14.64 | 3146 | 1842 | 2.01 / 615.00 | 20 | 58 |
4 | 13 | 1955.20 | 20 | 14.60 | 3041 | 888 | 2.90 / 615.88 | 6 | 64 |
5 | 13 | 1346.68 | 20 | 14.59 | 2246 | 655 | 3.55 / 616.54 | 6 | 76 |
6 | 13 | 718.40 | 20 | 14.70 | 1374 | 404 | 3.96 / 616.94 | 6 | 82 |
7 | 13 | 83.00 | 20 | 14.88 | 439 | 131 | 4.09 / 617.07 | 6 | 75 |
8 | 8 | 1.04 | 276 | 14.84 | 302 | 1237 | 5.32 / 618.31 | 6 | 132 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 25 | 14.85 | 449 | 167 | 0.17 / 607.74 | 6 | 21 |
2 | 7 | 2018.84 | 40 | 14.63 | 3124 | 1828 | 1.99 / 609.56 | 21 | 58 |
3 | 13 | 1920.96 | 20 | 14.60 | 3008 | 878 | 2.87 / 610.44 | 6 | 63 |
4 | 13 | 1368.88 | 20 | 14.61 | 2262 | 661 | 3.53 / 611.10 | 6 | 73 |
5 | 13 | 920.00 | 20 | 14.65 | 1659 | 486 | 4.02 / 611.59 | 6 | 81 |
6 | 13 | 110.28 | 20 | 14.86 | 501 | 149 | 4.17 / 611.74 | 6 | 77 |
7 | 8 | -0.40 | 276 | 14.84 | 305 | 1249 | 5.42 / 612.99 | 6 | 132 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 25 | 14.85 | 454 | 169 | 0.17 / 602.43 | 6 | 19 |
2 | 7 | 2006.44 | 40 | 14.65 | 3095 | 1814 | 1.98 / 604.24 | 19 | 59 |
3 | 13 | 1807.36 | 20 | 14.62 | 2864 | 837 | 2.82 / 605.08 | 6 | 65 |
4 | 13 | 1492.44 | 20 | 14.59 | 2459 | 718 | 3.54 / 605.79 | 6 | 73 |
5 | 13 | 687.84 | 20 | 14.71 | 1348 | 397 | 3.93 / 606.19 | 6 | 84 |
6 | 13 | 63.84 | 20 | 14.89 | 421 | 125 | 4.06 / 606.32 | 6 | 73 |
7 | 8 | 1.08 | 276 | 14.84 | 306 | 1253 | 5.31 / 607.57 | 6 | 131 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 25 | 14.86 | 445 | 165 | 0.17 / 597.03 | 6 | 21 |
2 | 7 | 2009.20 | 41 | 14.64 | 3127 | 1877 | 2.04 / 598.90 | 21 | 58 |
3 | 13 | 1915.60 | 20 | 14.61 | 3001 | 877 | 2.92 / 599.78 | 6 | 65 |
4 | 13 | 1399.24 | 20 | 14.60 | 2323 | 678 | 3.60 / 600.46 | 6 | 75 |
5 | 13 | 843.04 | 20 | 14.66 | 1541 | 452 | 4.05 / 600.91 | 6 | 80 |
6 | 13 | 81.00 | 20 | 14.87 | 439 | 131 | 4.18 / 601.04 | 6 | 75 |
7 | 8 | -0.44 | 274 | 14.84 | 299 | 1216 | 5.40 / 602.26 | 6 | 135 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 25 | 14.86 | 436 | 162 | 0.16 / 591.63 | 6 | 21 |
2 | 10 | 1002.52 | 3 | 14.99 | 1784 | 80 | 0.24 / 591.71 | 6 | 57 |
3 | 3 | 920.00 | -1 | 15.33 | 12 | 0 | 0.08 / 591.71 | 6 | 57 |
4 | 7 | 2012.88 | 40 | 14.64 | 3145 | 1842 | 2.08 / 593.55 | 57 | 60 |
5 | 13 | 1930.12 | 20 | 14.61 | 3002 | 877 | 2.96 / 594.43 | 6 | 63 |
6 | 13 | 1485.72 | 20 | 14.58 | 2447 | 714 | 3.67 / 595.14 | 6 | 72 |
7 | 13 | 621.24 | 20 | 14.73 | 1253 | 369 | 4.04 / 595.51 | 6 | 85 |
8 | 13 | 51.24 | 20 | 14.89 | 392 | 117 | 4.16 / 595.63 | 6 | 72 |
9 | 13 | 14.56 | 20 | 14.90 | 326 | 97 | 4.26 / 595.73 | 6 | 72 |
10 | 8 | 0.92 | 253 | 14.84 | 302 | 1134 | 5.39 / 596.86 | 6 | 135 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 26 | 14.86 | 446 | 172 | 0.17 / 586.26 | 6 | 19 |
2 | 3 | 957.72 | -1 | 15.34 | 12 | 0 | 0.00 / 586.26 | 6 | 19 |
3 | 7 | 2018.16 | 40 | 14.63 | 3143 | 1839 | 2.01 / 588.10 | 19 | 58 |
4 | 13 | 1924.24 | 20 | 14.60 | 3012 | 880 | 2.89 / 588.98 | 6 | 62 |
5 | 13 | 1397.16 | 20 | 14.60 | 2318 | 677 | 3.57 / 589.66 | 6 | 75 |
6 | 13 | 859.00 | 20 | 14.67 | 1550 | 455 | 4.02 / 590.11 | 6 | 81 |
7 | 13 | 178.56 | 20 | 14.85 | 581 | 173 | 4.20 / 590.29 | 6 | 77 |
8 | 8 | 0.08 | 267 | 14.84 | 299 | 1185 | 5.38 / 591.47 | 6 | 136 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 26 | 14.84 | 442 | 171 | 0.17 / 580.90 | 6 | 19 |
2 | 7 | 2018.84 | 41 | 14.63 | 3145 | 1886 | 2.06 / 582.79 | 19 | 58 |
3 | 13 | 1931.24 | 20 | 14.61 | 3025 | 884 | 2.94 / 583.67 | 6 | 62 |
4 | 13 | 1610.80 | 20 | 14.57 | 2588 | 754 | 3.70 / 584.43 | 6 | 72 |
5 | 13 | 623.88 | 20 | 14.74 | 1231 | 363 | 4.06 / 584.79 | 6 | 83 |
6 | 13 | 90.68 | 20 | 14.88 | 451 | 134 | 4.19 / 584.93 | 6 | 72 |
7 | 8 | 0.12 | 263 | 14.85 | 298 | 1164 | 5.36 / 586.09 | 6 | 133 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 26 | 14.85 | 440 | 170 | 0.17 / 575.43 | 6 | 16 |
2 | 7 | 2016.32 | 40 | 14.65 | 3114 | 1825 | 1.99 / 577.26 | 16 | 57 |
3 | 13 | 1834.00 | 20 | 14.62 | 2887 | 844 | 2.84 / 578.10 | 6 | 67 |
4 | 13 | 1530.44 | 20 | 14.59 | 2486 | 725 | 3.56 / 578.83 | 6 | 70 |
5 | 13 | 1163.60 | 20 | 14.59 | 1987 | 580 | 4.14 / 579.41 | 6 | 77 |
6 | 13 | 74.08 | 20 | 14.88 | 440 | 131 | 4.28 / 579.54 | 6 | 74 |
7 | 8 | 0.12 | 265 | 14.85 | 304 | 1196 | 5.47 / 580.73 | 6 | 136 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 26 | 14.87 | 445 | 172 | 0.17 / 569.94 | 6 | 18 |
2 | 3 | 1026.76 | 1 | 15.04 | 1838 | 28 | 0.20 / 569.97 | 6 | 28 |
3 | 7 | 2020.52 | 41 | 14.64 | 3140 | 1885 | 2.08 / 571.86 | 28 | 58 |
4 | 13 | 1934.44 | 20 | 14.61 | 3029 | 885 | 2.97 / 572.74 | 6 | 63 |
5 | 13 | 1296.52 | 20 | 14.62 | 2188 | 640 | 3.61 / 573.38 | 6 | 75 |
6 | 13 | 645.88 | 20 | 14.72 | 1277 | 376 | 3.99 / 573.76 | 6 | 84 |
7 | 13 | 314.28 | 20 | 14.80 | 795 | 235 | 4.22 / 573.99 | 6 | 83 |
8 | 13 | 33.12 | 20 | 14.88 | 367 | 109 | 4.33 / 574.10 | 6 | 77 |
9 | 8 | 0.04 | 255 | 14.83 | 307 | 1161 | 5.49 / 575.26 | 6 | 132 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 25 | 14.86 | 444 | 165 | 0.16 / 564.52 | 6 | 18 |
2 | 7 | 2007.40 | 41 | 14.64 | 3136 | 1882 | 2.05 / 566.40 | 11 | 58 |
3 | 13 | 1935.60 | 20 | 14.61 | 3043 | 889 | 2.94 / 567.29 | 6 | 64 |
4 | 13 | 1405.52 | 20 | 14.60 | 2330 | 680 | 3.62 / 567.97 | 6 | 73 |
5 | 13 | 843.08 | 20 | 14.69 | 1526 | 448 | 4.07 / 568.42 | 6 | 79 |
6 | 13 | 92.84 | 20 | 14.88 | 462 | 137 | 4.20 / 568.55 | 6 | 73 |
7 | 8 | -0.16 | 270 | 14.85 | 304 | 1219 | 5.42 / 569.77 | 6 | 130 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 27 | 14.86 | 443 | 178 | 0.18 / 559.13 | 6 | 20 |
2 | 3 | 935.00 | -1 | 15.34 | 12 | 0 | 0.00 / 559.13 | 6 | 20 |
3 | 7 | 2017.24 | 40 | 14.65 | 3138 | 1839 | 2.02 / 560.97 | 20 | 59 |
4 | 13 | 1937.48 | 20 | 14.62 | 3040 | 889 | 2.91 / 561.86 | 6 | 63 |
5 | 13 | 1408.56 | 20 | 14.61 | 2326 | 680 | 3.59 / 562.54 | 6 | 73 |
6 | 13 | 767.08 | 20 | 14.70 | 1428 | 420 | 4.00 / 562.96 | 6 | 82 |
7 | 13 | 190.80 | 20 | 14.85 | 597 | 177 | 4.18 / 563.14 | 6 | 78 |
8 | 8 | -0.12 | 274 | 14.85 | 298 | 1213 | 5.39 / 564.35 | 6 | 132 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 27 | 14.86 | 457 | 183 | 0.18 / 553.59 | 6 | 21 |
2 | 7 | 2010.88 | 40 | 14.65 | 3126 | 1832 | 2.02 / 555.42 | 7 | 57 |
3 | 13 | 1939.20 | 20 | 14.61 | 3028 | 885 | 2.90 / 556.31 | 6 | 63 |
4 | 13 | 1500.28 | 20 | 14.59 | 2458 | 717 | 3.62 / 557.03 | 6 | 72 |
5 | 13 | 1038.40 | 20 | 14.63 | 1804 | 528 | 4.15 / 557.55 | 6 | 79 |
6 | 13 | 61.76 | 20 | 14.90 | 413 | 123 | 4.27 / 557.68 | 6 | 74 |
7 | 13 | 33.80 | 20 | 14.90 | 364 | 108 | 4.38 / 557.79 | 6 | 75 |
8 | 8 | 0.04 | 259 | 14.85 | 304 | 1169 | 5.55 / 558.96 | 6 | 134 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 26 | 14.88 | 453 | 175 | 0.18 / 548.05 | 6 | 17 |
2 | 7 | 2007.76 | 41 | 14.65 | 3123 | 1876 | 2.05 / 549.93 | 10 | 60 |
3 | 13 | 1922.28 | 20 | 14.61 | 3006 | 878 | 2.93 / 550.81 | 6 | 62 |
4 | 13 | 1498.44 | 20 | 14.60 | 2442 | 713 | 3.64 / 551.52 | 6 | 70 |
5 | 13 | 917.40 | 20 | 14.66 | 1650 | 484 | 4.13 / 552.00 | 6 | 81 |
6 | 13 | 217.68 | 20 | 14.84 | 649 | 193 | 4.32 / 552.19 | 6 | 81 |
7 | 8 | -0.04 | 270 | 14.85 | 303 | 1215 | 5.53 / 553.41 | 6 | 129 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 26 | 14.87 | 439 | 170 | 0.17 / 542.70 | 6 | 16 |
2 | 7 | 2009.12 | 41 | 14.66 | 3110 | 1869 | 2.04 / 544.57 | 16 | 59 |
3 | 13 | 1820.40 | 20 | 14.63 | 2890 | 846 | 2.88 / 545.41 | 6 | 66 |
4 | 13 | 1411.40 | 20 | 14.61 | 2324 | 679 | 3.56 / 546.09 | 6 | 75 |
5 | 13 | 869.20 | 20 | 14.67 | 1586 | 465 | 4.03 / 546.56 | 6 | 80 |
6 | 13 | 83.64 | 20 | 14.89 | 444 | 132 | 4.16 / 546.69 | 6 | 76 |
7 | 8 | 0.28 | 266 | 14.86 | 300 | 1186 | 5.35 / 547.88 | 6 | 133 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 26 | 14.87 | 449 | 174 | 0.17 / 537.40 | 6 | 17 |
2 | 7 | 2004.92 | 40 | 14.67 | 3095 | 1816 | 1.99 / 539.22 | 8 | 60 |
3 | 13 | 1915.16 | 20 | 14.63 | 2989 | 875 | 2.86 / 540.09 | 6 | 63 |
4 | 13 | 1268.28 | 20 | 14.64 | 2142 | 627 | 3.49 / 540.72 | 6 | 75 |
5 | 13 | 742.24 | 20 | 14.72 | 1414 | 416 | 3.91 / 541.13 | 6 | 83 |
6 | 13 | 84.60 | 20 | 14.89 | 453 | 135 | 4.04 / 541.27 | 6 | 76 |
7 | 13 | 22.36 | 20 | 14.91 | 349 | 104 | 4.15 / 541.37 | 6 | 76 |
8 | 8 | -0.24 | 255 | 14.86 | 305 | 1156 | 5.30 / 542.53 | 6 | 129 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 26 | 14.89 | 442 | 171 | 0.17 / 532.13 | 6 | 17 |
2 | 7 | 2006.00 | 40 | 14.66 | 3091 | 1813 | 1.98 / 533.95 | 17 | 58 |
3 | 13 | 1921.32 | 20 | 14.62 | 2998 | 877 | 2.86 / 534.82 | 6 | 63 |
4 | 13 | 1277.48 | 20 | 14.64 | 2140 | 627 | 3.49 / 535.45 | 6 | 75 |
5 | 13 | 732.24 | 20 | 14.71 | 1410 | 415 | 3.90 / 535.86 | 6 | 84 |
6 | 13 | 42.04 | 20 | 14.90 | 384 | 114 | 4.02 / 535.98 | 6 | 74 |
7 | 8 | 0.24 | 272 | 14.85 | 309 | 1248 | 5.26 / 537.23 | 6 | 137 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 27 | 14.89 | 441 | 177 | 0.18 / 526.86 | 6 | 17 |
2 | 3 | 957.72 | -1 | 15.35 | 12 | 0 | 0.00 / 526.86 | 6 | 17 |
3 | 7 | 2010.36 | 40 | 14.66 | 3111 | 1824 | 2.00 / 528.68 | 17 | 60 |
4 | 13 | 1923.04 | 20 | 14.62 | 3007 | 879 | 2.88 / 529.56 | 6 | 63 |
5 | 13 | 1489.52 | 20 | 14.61 | 2426 | 709 | 3.59 / 530.27 | 6 | 73 |
6 | 13 | 835.20 | 20 | 14.70 | 1518 | 446 | 4.04 / 530.71 | 6 | 81 |
7 | 13 | 41.08 | 20 | 14.92 | 377 | 112 | 4.15 / 530.83 | 6 | 75 |
8 | 13 | 19.16 | 20 | 14.92 | 339 | 101 | 4.25 / 530.93 | 6 | 75 |
9 | 8 | -0.12 | 231 | 14.87 | 301 | 1034 | 5.28 / 531.96 | 6 | 133 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 27 | 14.87 | 464 | 186 | 0.19 / 521.27 | 6 | 15 |
2 | 7 | 2003.84 | 40 | 14.66 | 3100 | 1818 | 2.00 / 523.09 | 15 | 59 |
3 | 13 | 1925.20 | 20 | 14.62 | 3016 | 882 | 2.89 / 523.97 | 6 | 63 |
4 | 13 | 1608.00 | 20 | 14.60 | 2578 | 753 | 3.64 / 524.72 | 6 | 71 |
5 | 13 | 1157.36 | 20 | 14.62 | 1971 | 576 | 4.22 / 525.30 | 6 | 79 |
6 | 13 | 69.24 | 20 | 14.91 | 424 | 126 | 4.34 / 525.42 | 6 | 75 |
7 | 13 | 20.00 | 20 | 14.92 | 344 | 103 | 4.44 / 525.53 | 6 | 76 |
8 | 8 | 0.04 | 255 | 14.87 | 304 | 1153 | 5.60 / 526.68 | 6 | 130 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 27 | 14.89 | 446 | 179 | 0.18 / 515.94 | 6 | 16 |
2 | 7 | 2015.68 | 40 | 14.67 | 3095 | 1816 | 2.00 / 517.75 | 16 | 56 |
3 | 13 | 1929.52 | 20 | 14.63 | 3003 | 879 | 2.87 / 518.63 | 6 | 63 |
4 | 13 | 1368.64 | 20 | 14.64 | 2255 | 660 | 3.53 / 519.29 | 6 | 74 |
5 | 13 | 729.12 | 20 | 14.72 | 1390 | 409 | 3.94 / 519.70 | 6 | 83 |
6 | 13 | 168.24 | 20 | 14.86 | 576 | 171 | 4.11 / 519.87 | 6 | 78 |
7 | 13 | 38.44 | 20 | 14.90 | 370 | 110 | 4.23 / 519.98 | 6 | 77 |
8 | 8 | -0.04 | 246 | 14.85 | 301 | 1100 | 5.32 / 521.08 | 6 | 132 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 26 | 14.88 | 451 | 174 | 0.17 / 510.55 | 6 | 13 |
2 | 3 | 1022.68 | 1 | 15.05 | 1842 | 28 | 0.20 / 510.58 | 6 | 25 |
3 | 7 | 2004.92 | 41 | 14.65 | 3113 | 1870 | 2.07 / 512.45 | 25 | 59 |
4 | 13 | 1921.20 | 20 | 14.62 | 3021 | 883 | 2.96 / 513.33 | 6 | 62 |
5 | 13 | 1310.52 | 20 | 14.64 | 2209 | 647 | 3.60 / 513.98 | 6 | 75 |
6 | 13 | 780.40 | 20 | 14.70 | 1464 | 430 | 4.03 / 514.41 | 6 | 83 |
7 | 13 | 55.44 | 20 | 14.91 | 407 | 121 | 4.15 / 514.53 | 6 | 73 |
8 | 13 | 33.36 | 20 | 14.91 | 367 | 109 | 4.26 / 514.64 | 6 | 75 |
9 | 8 | 0.12 | 244 | 14.86 | 308 | 1117 | 5.38 / 515.76 | 6 | 131 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 27 | 14.88 | 437 | 176 | 0.18 / 505.26 | 6 | 13 |
2 | 7 | 2004.36 | 40 | 14.67 | 3081 | 1808 | 1.98 / 507.07 | 13 | 60 |
3 | 13 | 1910.64 | 20 | 14.64 | 2970 | 870 | 2.85 / 507.94 | 6 | 63 |
4 | 13 | 1374.96 | 20 | 14.63 | 2276 | 666 | 3.52 / 508.60 | 6 | 74 |
5 | 13 | 745.96 | 20 | 14.72 | 1411 | 415 | 3.93 / 509.02 | 6 | 83 |
6 | 13 | 86.76 | 20 | 14.90 | 444 | 132 | 4.07 / 509.15 | 6 | 75 |
7 | 8 | -0.04 | 276 | 14.87 | 299 | 1227 | 5.29 / 510.38 | 6 | 141 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 26 | 14.89 | 453 | 175 | 0.18 / 499.91 | 6 | 13 |
2 | 3 | 1038.00 | 1 | 15.04 | 1858 | 28 | 0.20 / 499.93 | 6 | 33 |
3 | 7 | 2007.20 | 40 | 14.66 | 3129 | 1835 | 2.04 / 501.77 | 33 | 58 |
4 | 13 | 1923.24 | 20 | 14.63 | 3012 | 881 | 2.92 / 502.65 | 6 | 64 |
5 | 13 | 1310.52 | 20 | 14.64 | 2197 | 643 | 3.56 / 503.29 | 6 | 74 |
6 | 13 | 770.00 | 20 | 14.71 | 1452 | 427 | 3.99 / 503.72 | 6 | 82 |
7 | 13 | 57.84 | 20 | 14.91 | 401 | 120 | 4.11 / 503.84 | 6 | 75 |
8 | 13 | 15.00 | 20 | 14.92 | 331 | 99 | 4.21 / 503.94 | 6 | 74 |
9 | 8 | 0.12 | 255 | 14.86 | 302 | 1144 | 5.35 / 505.08 | 6 | 132 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 27 | 14.88 | 436 | 175 | 0.18 / 494.72 | 6 | 14 |
2 | 7 | 2004.64 | 40 | 14.67 | 3081 | 1808 | 1.98 / 496.53 | 14 | 58 |
3 | 13 | 1917.08 | 20 | 14.65 | 2958 | 867 | 2.85 / 497.39 | 6 | 64 |
4 | 13 | 1312.00 | 20 | 14.64 | 2187 | 640 | 3.49 / 498.03 | 6 | 74 |
5 | 13 | 659.84 | 20 | 14.75 | 1283 | 378 | 3.87 / 498.41 | 6 | 83 |
6 | 13 | 56.60 | 20 | 14.92 | 391 | 117 | 3.99 / 498.53 | 6 | 74 |
7 | 13 | 31.28 | 20 | 14.92 | 351 | 105 | 4.09 / 498.63 | 6 | 74 |
8 | 8 | 0.04 | 248 | 14.87 | 297 | 1095 | 5.19 / 499.73 | 6 | 136 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 27 | 14.88 | 448 | 180 | 0.18 / 489.43 | 6 | 12 |
2 | 7 | 2012.92 | 40 | 14.67 | 3096 | 1817 | 2.00 / 491.25 | 12 | 58 |
3 | 13 | 1920.12 | 20 | 14.64 | 3000 | 878 | 2.88 / 492.13 | 6 | 62 |
4 | 13 | 1280.16 | 20 | 14.66 | 2127 | 624 | 3.50 / 492.75 | 6 | 77 |
5 | 13 | 831.28 | 20 | 14.69 | 1538 | 452 | 3.95 / 493.20 | 6 | 82 |
6 | 13 | 45.76 | 20 | 14.91 | 386 | 115 | 4.07 / 493.32 | 6 | 76 |
7 | 8 | 0.16 | 274 | 14.87 | 301 | 1226 | 5.29 / 494.54 | 6 | 134 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 26 | 14.89 | 466 | 180 | 0.18 / 483.99 | 6 | 17 |
2 | 7 | 2007.28 | 41 | 14.67 | 3095 | 1862 | 2.04 / 485.85 | 11 | 60 |
3 | 13 | 1916.60 | 20 | 14.63 | 2991 | 875 | 2.92 / 486.73 | 6 | 64 |
4 | 13 | 1467.88 | 20 | 14.62 | 2405 | 703 | 3.62 / 487.43 | 6 | 73 |
5 | 13 | 803.96 | 20 | 14.71 | 1488 | 438 | 4.06 / 487.87 | 6 | 82 |
6 | 13 | 58.68 | 20 | 14.92 | 413 | 123 | 4.18 / 487.99 | 6 | 75 |
7 | 13 | 15.72 | 20 | 14.92 | 338 | 101 | 4.28 / 488.09 | 6 | 73 |
8 | 8 | 0.04 | 253 | 14.87 | 308 | 1159 | 5.44 / 489.25 | 6 | 133 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 26 | 14.89 | 454 | 176 | 0.18 / 478.62 | 6 | 13 |
2 | 3 | 1020.00 | 1 | 15.08 | 1844 | 28 | 0.20 / 478.64 | 6 | 17 |
3 | 7 | 2013.84 | 40 | 14.67 | 3116 | 1828 | 2.03 / 480.47 | 17 | 59 |
4 | 13 | 1922.32 | 20 | 14.63 | 3018 | 883 | 2.92 / 481.36 | 6 | 64 |
5 | 13 | 1481.96 | 20 | 14.62 | 2428 | 710 | 3.63 / 482.07 | 6 | 72 |
6 | 13 | 644.00 | 20 | 14.75 | 1290 | 381 | 4.01 / 482.45 | 6 | 83 |
7 | 13 | 50.76 | 20 | 14.92 | 394 | 118 | 4.12 / 482.56 | 6 | 76 |
8 | 8 | 0.04 | 274 | 14.88 | 306 | 1248 | 5.37 / 483.81 | 6 | 145 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 25 | 14.89 | 441 | 164 | 0.16 / 473.12 | 6 | 16 |
2 | 3 | 1024.24 | 1 | 15.06 | 1853 | 28 | 0.19 / 473.15 | 6 | 14 |
3 | 7 | 2007.12 | 40 | 14.68 | 3095 | 1817 | 2.01 / 474.96 | 14 | 58 |
4 | 13 | 1920.84 | 20 | 14.65 | 2966 | 869 | 2.88 / 475.83 | 6 | 62 |
5 | 13 | 1470.44 | 20 | 14.63 | 2396 | 701 | 3.58 / 476.53 | 6 | 74 |
6 | 13 | 1033.52 | 20 | 14.67 | 1799 | 528 | 4.11 / 477.06 | 6 | 81 |
7 | 13 | 108.04 | 20 | 14.91 | 477 | 142 | 4.25 / 477.20 | 6 | 75 |
8 | 8 | -0.48 | 276 | 14.88 | 301 | 1236 | 5.49 / 478.44 | 6 | 129 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 26 | 14.88 | 435 | 168 | 0.17 / 467.77 | 6 | 14 |
2 | 7 | 2018.80 | 40 | 14.66 | 3122 | 1831 | 2.00 / 469.60 | 14 | 59 |
3 | 13 | 1942.24 | 20 | 14.62 | 3037 | 888 | 2.89 / 470.49 | 6 | 63 |
4 | 13 | 1407.92 | 20 | 14.63 | 2319 | 679 | 3.57 / 471.16 | 6 | 75 |
5 | 13 | 748.64 | 20 | 14.72 | 1421 | 418 | 3.98 / 471.58 | 6 | 82 |
6 | 13 | 88.56 | 20 | 14.91 | 464 | 138 | 4.12 / 471.72 | 6 | 77 |
7 | 8 | 0.28 | 274 | 14.87 | 303 | 1235 | 5.36 / 472.96 | 6 | 130 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 25 | 14.90 | 444 | 165 | 0.17 / 462.44 | 6 | 15 |
2 | 3 | 1031.32 | 1 | 15.07 | 1821 | 27 | 0.19 / 462.47 | 6 | 31 |
3 | 7 | 2009.68 | 41 | 14.67 | 3096 | 1862 | 2.05 / 464.33 | 31 | 59 |
4 | 13 | 1813.56 | 20 | 14.65 | 2869 | 841 | 2.90 / 465.17 | 6 | 66 |
5 | 13 | 1185.44 | 20 | 14.68 | 1997 | 586 | 3.48 / 465.76 | 6 | 77 |
6 | 13 | 870.00 | 20 | 14.69 | 1581 | 464 | 3.95 / 466.22 | 6 | 82 |
7 | 13 | 83.80 | 20 | 14.90 | 445 | 133 | 4.08 / 466.36 | 6 | 74 |
8 | 13 | 18.68 | 20 | 14.92 | 340 | 101 | 4.18 / 466.46 | 6 | 72 |
9 | 8 | -0.36 | 253 | 14.87 | 303 | 1140 | 5.32 / 467.60 | 6 | 131 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 26 | 14.89 | 443 | 172 | 0.17 / 457.25 | 6 | 22 |
2 | 7 | 2006.80 | 40 | 14.67 | 3104 | 1821 | 1.99 / 459.07 | 22 | 61 |
3 | 13 | 1915.20 | 20 | 14.64 | 2996 | 877 | 2.87 / 459.95 | 6 | 66 |
4 | 13 | 1263.36 | 20 | 14.67 | 2121 | 622 | 3.49 / 460.57 | 6 | 78 |
5 | 13 | 642.40 | 20 | 14.77 | 1266 | 374 | 3.87 / 460.95 | 6 | 84 |
6 | 13 | 34.16 | 20 | 14.94 | 362 | 108 | 3.97 / 461.05 | 6 | 70 |
7 | 8 | 0.00 | 272 | 14.89 | 302 | 1223 | 5.20 / 462.28 | 6 | 130 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 26 | 14.89 | 454 | 176 | 0.18 / 451.81 | 6 | 21 |
2 | 3 | 967.88 | -1 | 15.36 | 12 | 0 | 0.00 / 451.81 | 6 | 21 |
3 | 7 | 2005.36 | 41 | 14.67 | 3109 | 1870 | 2.05 / 453.68 | 21 | 58 |
4 | 13 | 1917.80 | 20 | 14.65 | 3004 | 880 | 2.93 / 454.56 | 6 | 64 |
5 | 13 | 1496.96 | 20 | 14.62 | 2446 | 715 | 3.64 / 455.27 | 6 | 72 |
6 | 13 | 824.64 | 20 | 14.71 | 1518 | 447 | 4.09 / 455.72 | 6 | 77 |
7 | 13 | 64.52 | 20 | 14.93 | 418 | 125 | 4.21 / 455.84 | 6 | 74 |
8 | 8 | 0.00 | 270 | 14.89 | 308 | 1238 | 5.45 / 457.08 | 6 | 130 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 26 | 14.90 | 444 | 172 | 0.17 / 446.50 | 6 | 18 |
2 | 7 | 2010.04 | 40 | 14.67 | 3112 | 1826 | 2.00 / 448.33 | 6 | 59 |
3 | 13 | 1935.76 | 20 | 14.65 | 3011 | 882 | 2.88 / 449.21 | 6 | 63 |
4 | 13 | 1313.20 | 20 | 14.65 | 2187 | 641 | 3.52 / 449.85 | 6 | 76 |
5 | 13 | 877.00 | 20 | 14.69 | 1604 | 471 | 3.99 / 450.32 | 6 | 80 |
6 | 13 | 45.00 | 20 | 14.93 | 385 | 115 | 4.11 / 450.44 | 6 | 73 |
7 | 8 | 0.00 | 264 | 14.89 | 303 | 1191 | 5.30 / 451.63 | 6 | 143 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 26 | 14.88 | 450 | 174 | 0.17 / 441.12 | 6 | 20 |
2 | 7 | 2016.08 | 40 | 14.68 | 3107 | 1824 | 2.00 / 442.95 | 20 | 58 |
3 | 13 | 1923.48 | 20 | 14.65 | 3000 | 879 | 2.88 / 443.83 | 6 | 64 |
4 | 13 | 1390.08 | 20 | 14.63 | 2324 | 680 | 3.56 / 444.51 | 6 | 73 |
5 | 13 | 840.48 | 20 | 14.71 | 1547 | 455 | 4.01 / 444.96 | 6 | 80 |
6 | 13 | 87.92 | 20 | 14.92 | 462 | 138 | 4.15 / 445.10 | 6 | 74 |
7 | 8 | 0.28 | 272 | 14.89 | 304 | 1231 | 5.38 / 446.33 | 6 | 135 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 26 | 14.89 | 466 | 180 | 0.18 / 435.65 | 6 | 20 |
2 | 7 | 2004.40 | 41 | 14.69 | 3073 | 1851 | 2.03 / 437.50 | 20 | 60 |
3 | 13 | 1907.56 | 20 | 14.66 | 2959 | 868 | 2.90 / 438.36 | 6 | 64 |
4 | 13 | 1479.36 | 20 | 14.64 | 2411 | 706 | 3.60 / 439.07 | 6 | 72 |
5 | 13 | 793.44 | 20 | 14.73 | 1477 | 435 | 4.04 / 439.50 | 6 | 82 |
6 | 13 | 215.20 | 20 | 14.88 | 652 | 194 | 4.23 / 439.70 | 6 | 80 |
7 | 13 | 37.24 | 20 | 14.92 | 378 | 113 | 4.35 / 439.81 | 6 | 77 |
8 | 8 | -0.40 | 246 | 14.87 | 311 | 1138 | 5.48 / 440.95 | 6 | 129 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 26 | 14.90 | 455 | 176 | 0.18 / 430.18 | 6 | 18 |
2 | 3 | 1019.84 | 1 | 15.08 | 1863 | 28 | 0.20 / 430.21 | 6 | 16 |
3 | 7 | 2002.20 | 40 | 14.68 | 3116 | 1830 | 2.03 / 432.04 | 16 | 58 |
4 | 13 | 1808.72 | 20 | 14.65 | 2864 | 839 | 2.87 / 432.88 | 6 | 66 |
5 | 13 | 1600.64 | 20 | 14.62 | 2591 | 758 | 3.63 / 433.64 | 6 | 71 |
6 | 13 | 800.16 | 20 | 14.73 | 1493 | 440 | 4.07 / 434.08 | 6 | 80 |
7 | 13 | 227.76 | 20 | 14.88 | 669 | 199 | 4.27 / 434.28 | 6 | 81 |
8 | 8 | 0.20 | 261 | 14.89 | 306 | 1189 | 5.46 / 435.46 | 6 | 131 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 25 | 14.89 | 453 | 169 | 0.17 / 424.92 | 6 | 23 |
2 | 3 | 1031.76 | 1 | 15.07 | 1834 | 28 | 0.20 / 424.95 | 6 | 39 |
3 | 7 | 2009.48 | 40 | 14.69 | 3097 | 1820 | 2.02 / 426.77 | 39 | 62 |
4 | 13 | 1923.12 | 20 | 14.66 | 3002 | 880 | 2.90 / 427.65 | 6 | 63 |
5 | 13 | 1295.12 | 20 | 14.68 | 2162 | 635 | 3.53 / 428.29 | 6 | 76 |
6 | 13 | 615.52 | 20 | 14.78 | 1240 | 367 | 3.90 / 428.65 | 6 | 85 |
7 | 13 | 49.32 | 20 | 14.94 | 396 | 118 | 4.02 / 428.77 | 6 | 73 |
8 | 8 | 0.88 | 270 | 14.89 | 307 | 1234 | 5.25 / 430.01 | 6 | 139 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 26 | 14.90 | 458 | 177 | 0.18 / 419.55 | 6 | 21 |
2 | 7 | 2004.48 | 40 | 14.69 | 3076 | 1807 | 1.98 / 421.36 | 21 | 57 |
3 | 13 | 1907.00 | 20 | 14.66 | 2983 | 875 | 2.86 / 422.24 | 6 | 64 |
4 | 13 | 1269.68 | 20 | 14.67 | 2137 | 627 | 3.49 / 422.86 | 6 | 75 |
5 | 13 | 719.80 | 20 | 14.75 | 1386 | 409 | 3.90 / 423.27 | 6 | 84 |
6 | 13 | 274.64 | 20 | 14.86 | 739 | 220 | 4.11 / 423.49 | 6 | 84 |
7 | 8 | -0.52 | 274 | 14.88 | 310 | 1264 | 5.38 / 424.76 | 6 | 134 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 26 | 14.91 | 470 | 182 | 0.18 / 414.22 | 6 | 20 |
2 | 7 | 2007.40 | 40 | 14.68 | 3107 | 1824 | 2.01 / 416.05 | 20 | 58 |
3 | 13 | 1914.40 | 20 | 14.65 | 2990 | 876 | 2.88 / 416.92 | 6 | 63 |
4 | 13 | 1365.52 | 20 | 14.65 | 2284 | 669 | 3.55 / 417.59 | 6 | 74 |
5 | 13 | 798.96 | 20 | 14.73 | 1485 | 437 | 3.99 / 418.03 | 6 | 81 |
6 | 13 | 70.96 | 20 | 14.93 | 433 | 129 | 4.12 / 418.16 | 6 | 74 |
7 | 8 | 0.56 | 265 | 14.90 | 308 | 1216 | 5.33 / 419.38 | 6 | 131 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 26 | 14.89 | 453 | 175 | 0.18 / 408.84 | 6 | 20 |
2 | 7 | 2007.56 | 41 | 14.69 | 3097 | 1865 | 2.04 / 410.71 | 6 | 59 |
3 | 13 | 1708.72 | 20 | 14.67 | 2724 | 799 | 2.84 / 411.51 | 6 | 69 |
4 | 13 | 1613.12 | 20 | 14.62 | 2589 | 757 | 3.60 / 412.26 | 6 | 70 |
5 | 13 | 804.24 | 20 | 14.73 | 1495 | 440 | 4.04 / 412.70 | 6 | 82 |
6 | 13 | 73.88 | 20 | 14.94 | 433 | 129 | 4.17 / 412.83 | 6 | 73 |
7 | 8 | 0.24 | 266 | 14.90 | 305 | 1209 | 5.38 / 414.04 | 6 | 132 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 26 | 14.90 | 451 | 175 | 0.17 / 403.27 | 6 | 22 |
2 | 7 | 2004.08 | 40 | 14.70 | 3074 | 1808 | 1.98 / 405.08 | 22 | 58 |
3 | 13 | 1910.88 | 20 | 14.67 | 2962 | 869 | 2.85 / 405.95 | 6 | 63 |
4 | 13 | 1462.64 | 20 | 14.66 | 2385 | 699 | 3.55 / 406.65 | 6 | 74 |
5 | 13 | 985.28 | 20 | 14.69 | 1743 | 512 | 4.06 / 407.16 | 6 | 81 |
6 | 13 | 299.96 | 20 | 14.85 | 783 | 233 | 4.30 / 407.39 | 6 | 83 |
7 | 8 | -0.56 | 276 | 14.88 | 310 | 1273 | 5.57 / 408.67 | 6 | 134 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 26 | 14.91 | 448 | 174 | 0.17 / 398.00 | 6 | 17 |
2 | 7 | 2003.52 | 40 | 14.70 | 3079 | 1810 | 1.98 / 399.81 | 17 | 58 |
3 | 13 | 1917.48 | 20 | 14.66 | 2971 | 871 | 2.86 / 400.68 | 6 | 65 |
4 | 13 | 1477.88 | 20 | 14.64 | 2411 | 706 | 3.56 / 401.39 | 6 | 72 |
5 | 13 | 712.84 | 20 | 14.76 | 1368 | 404 | 3.96 / 401.79 | 6 | 84 |
6 | 13 | 72.92 | 20 | 14.94 | 424 | 127 | 4.09 / 401.92 | 6 | 74 |
7 | 8 | 0.60 | 261 | 14.90 | 304 | 1182 | 5.27 / 403.10 | 6 | 129 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 27 | 14.90 | 450 | 181 | 0.18 / 392.83 | 6 | 20 |
2 | 3 | 936.80 | -1 | 15.38 | 12 | 0 | 0.00 / 392.83 | 6 | 20 |
3 | 7 | 2005.60 | 40 | 14.70 | 3082 | 1812 | 1.99 / 394.65 | 20 | 58 |
4 | 13 | 1913.80 | 20 | 14.67 | 2965 | 870 | 2.86 / 395.52 | 6 | 64 |
5 | 13 | 1285.56 | 20 | 14.68 | 2155 | 633 | 3.50 / 396.15 | 6 | 75 |
6 | 13 | 536.60 | 20 | 14.81 | 1128 | 334 | 3.83 / 396.48 | 6 | 84 |
7 | 13 | 56.12 | 20 | 14.94 | 403 | 120 | 3.95 / 396.60 | 6 | 74 |
8 | 8 | 0.16 | 267 | 14.90 | 307 | 1221 | 5.17 / 397.82 | 6 | 132 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 26 | 14.90 | 461 | 179 | 0.18 / 387.27 | 6 | 17 |
2 | 10 | 1006.36 | 3 | 15.03 | 1787 | 81 | 0.26 / 387.35 | 6 | 55 |
3 | 3 | 923.52 | -1 | 15.37 | 13 | 0 | 0.08 / 387.35 | 6 | 55 |
4 | 7 | 2009.48 | 40 | 14.70 | 3085 | 1814 | 2.07 / 389.17 | 55 | 58 |
5 | 13 | 1922.76 | 20 | 14.67 | 2984 | 876 | 2.95 / 390.04 | 6 | 65 |
6 | 13 | 1598.76 | 20 | 14.63 | 2582 | 755 | 3.70 / 390.80 | 6 | 71 |
7 | 13 | 886.04 | 20 | 14.72 | 1614 | 475 | 4.18 / 391.27 | 6 | 79 |
8 | 13 | 53.96 | 20 | 14.95 | 401 | 120 | 4.30 / 391.39 | 6 | 72 |
9 | 8 | -0.44 | 276 | 14.90 | 306 | 1258 | 5.56 / 392.65 | 6 | 133 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 28 | 14.90 | 459 | 191 | 0.19 / 381.83 | 6 | 19 |
2 | 3 | 927.04 | -1 | 15.38 | 12 | 0 | 0.00 / 381.83 | 6 | 19 |
3 | 7 | 2018.60 | 40 | 14.69 | 3136 | 1843 | 2.03 / 383.67 | 19 | 58 |
4 | 13 | 1931.92 | 20 | 14.65 | 3025 | 886 | 2.92 / 384.56 | 6 | 66 |
5 | 13 | 1398.12 | 20 | 14.65 | 2328 | 682 | 3.60 / 385.24 | 6 | 74 |
6 | 13 | 916.76 | 20 | 14.70 | 1662 | 489 | 4.09 / 385.73 | 6 | 83 |
7 | 13 | 50.16 | 20 | 14.94 | 397 | 119 | 4.21 / 385.85 | 6 | 75 |
8 | 8 | 0.88 | 274 | 14.89 | 306 | 1248 | 5.46 / 387.09 | 6 | 134 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 26 | 14.93 | 459 | 178 | 0.18 / 376.38 | 6 | 16 |
2 | 10 | 1045.60 | 3 | 15.02 | 1839 | 83 | 0.26 / 376.46 | 6 | 59 |
3 | 3 | 946.56 | -1 | 15.37 | 12 | 0 | 0.08 / 376.46 | 6 | 59 |
4 | 7 | 2005.76 | 41 | 14.69 | 3101 | 1868 | 2.13 / 378.33 | 59 | 59 |
5 | 13 | 1906.96 | 20 | 14.67 | 2977 | 873 | 3.00 / 379.20 | 6 | 65 |
6 | 13 | 1251.44 | 20 | 14.68 | 2110 | 619 | 3.62 / 379.82 | 6 | 77 |
7 | 13 | 826.96 | 20 | 14.73 | 1503 | 443 | 4.06 / 380.26 | 6 | 81 |
8 | 13 | 57.52 | 20 | 14.94 | 405 | 121 | 4.19 / 380.39 | 6 | 74 |
9 | 8 | -0.44 | 272 | 14.89 | 309 | 1251 | 5.44 / 381.64 | 6 | 133 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 27 | 14.91 | 457 | 184 | 0.18 / 371.08 | 6 | 17 |
2 | 3 | 961.72 | -1 | 15.39 | 12 | 0 | 0.00 / 371.08 | 6 | 17 |
3 | 7 | 2006.16 | 40 | 14.70 | 3089 | 1816 | 2.00 / 372.90 | 17 | 60 |
4 | 13 | 1915.92 | 20 | 14.66 | 2974 | 872 | 2.87 / 373.77 | 6 | 63 |
5 | 13 | 1394.68 | 20 | 14.66 | 2296 | 673 | 3.55 / 374.44 | 6 | 75 |
6 | 13 | 716.04 | 20 | 14.76 | 1370 | 404 | 3.95 / 374.85 | 6 | 85 |
7 | 13 | 86.92 | 20 | 14.94 | 448 | 134 | 4.08 / 374.98 | 6 | 75 |
8 | 8 | 0.52 | 274 | 14.91 | 298 | 1217 | 5.30 / 376.20 | 6 | 131 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 25 | 14.93 | 457 | 171 | 0.17 / 365.72 | 6 | 17 |
2 | 10 | 1029.92 | 3 | 15.05 | 1813 | 82 | 0.25 / 365.80 | 6 | 58 |
3 | 3 | 952.88 | -1 | 15.38 | 12 | 0 | 0.08 / 365.80 | 6 | 58 |
4 | 7 | 2011.12 | 40 | 14.71 | 3092 | 1819 | 2.07 / 367.62 | 58 | 60 |
5 | 13 | 1912.64 | 20 | 14.67 | 2995 | 879 | 2.95 / 368.50 | 6 | 63 |
6 | 13 | 1249.72 | 20 | 14.71 | 2100 | 618 | 3.57 / 369.12 | 6 | 76 |
7 | 13 | 690.48 | 20 | 14.77 | 1354 | 400 | 3.97 / 369.52 | 6 | 83 |
8 | 13 | 64.36 | 20 | 14.94 | 420 | 125 | 4.09 / 369.65 | 6 | 76 |
9 | 8 | 0.60 | 274 | 14.90 | 307 | 1253 | 5.35 / 370.90 | 6 | 135 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 27 | 14.89 | 444 | 179 | 0.18 / 360.39 | 6 | 18 |
2 | 3 | 923.04 | -1 | 15.39 | 12 | 0 | 0.00 / 360.39 | 6 | 18 |
3 | 7 | 2006.48 | 40 | 14.71 | 3118 | 1835 | 2.01 / 362.22 | 18 | 61 |
4 | 13 | 1928.64 | 20 | 14.67 | 3018 | 885 | 2.90 / 363.11 | 6 | 65 |
5 | 13 | 1366.64 | 20 | 14.67 | 2280 | 669 | 3.57 / 363.78 | 6 | 75 |
6 | 13 | 739.20 | 20 | 14.76 | 1417 | 418 | 3.99 / 364.20 | 6 | 85 |
7 | 13 | 50.28 | 20 | 14.96 | 394 | 118 | 4.10 / 364.31 | 6 | 73 |
8 | 8 | 0.32 | 274 | 14.91 | 303 | 1238 | 5.34 / 365.55 | 6 | 140 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 26 | 14.94 | 460 | 179 | 0.18 / 354.86 | 6 | 14 |
2 | 10 | 1015.44 | 3 | 15.04 | 1814 | 82 | 0.26 / 354.94 | 6 | 57 |
3 | 3 | 940.56 | -1 | 15.39 | 12 | 0 | 0.08 / 354.94 | 6 | 57 |
4 | 7 | 2002.72 | 40 | 14.72 | 3093 | 1821 | 2.08 / 356.76 | 57 | 60 |
5 | 13 | 1907.92 | 20 | 14.67 | 2986 | 876 | 2.96 / 357.64 | 6 | 64 |
6 | 13 | 1379.48 | 20 | 14.67 | 2291 | 672 | 3.63 / 358.31 | 6 | 76 |
7 | 13 | 615.12 | 20 | 14.80 | 1231 | 364 | 3.99 / 358.68 | 6 | 84 |
8 | 13 | 397.32 | 20 | 14.84 | 919 | 273 | 4.27 / 358.95 | 6 | 85 |
9 | 13 | 21.44 | 20 | 14.94 | 349 | 104 | 4.37 / 359.05 | 6 | 75 |
10 | 8 | -0.24 | 253 | 14.89 | 307 | 1157 | 5.53 / 360.21 | 6 | 133 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 26 | 14.95 | 444 | 173 | 0.17 / 349.54 | 6 | 13 |
2 | 3 | 966.12 | -1 | 15.40 | 12 | 0 | 0.00 / 349.54 | 6 | 13 |
3 | 7 | 2008.04 | 41 | 14.70 | 3114 | 1877 | 2.05 / 351.42 | 13 | 59 |
4 | 13 | 1711.96 | 20 | 14.69 | 2748 | 807 | 2.86 / 352.23 | 6 | 67 |
5 | 13 | 1511.44 | 20 | 14.65 | 2471 | 724 | 3.58 / 352.95 | 6 | 72 |
6 | 13 | 626.92 | 20 | 14.80 | 1264 | 374 | 3.95 / 353.33 | 6 | 84 |
7 | 13 | 44.12 | 20 | 14.97 | 385 | 115 | 4.07 / 353.44 | 6 | 73 |
8 | 8 | 0.24 | 270 | 14.92 | 308 | 1241 | 5.31 / 354.68 | 6 | 144 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 26 | 14.94 | 455 | 177 | 0.18 / 344.14 | 6 | 13 |
2 | 7 | 2028.28 | 41 | 14.70 | 3128 | 1885 | 2.06 / 346.03 | 13 | 58 |
3 | 13 | 1936.88 | 20 | 14.66 | 3037 | 890 | 2.95 / 346.92 | 6 | 62 |
4 | 13 | 1395.76 | 20 | 14.67 | 2324 | 682 | 3.63 / 347.60 | 6 | 74 |
5 | 13 | 721.48 | 20 | 14.78 | 1394 | 412 | 4.05 / 348.01 | 6 | 83 |
6 | 13 | 41.84 | 20 | 14.97 | 384 | 115 | 4.16 / 348.13 | 6 | 72 |
7 | 8 | 0.36 | 272 | 14.92 | 306 | 1242 | 5.40 / 349.37 | 6 | 134 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 26 | 14.94 | 463 | 180 | 0.18 / 338.60 | 6 | 12 |
2 | 7 | 2007.12 | 41 | 14.70 | 3127 | 1885 | 2.06 / 340.49 | 6 | 59 |
3 | 13 | 1913.96 | 20 | 14.68 | 2999 | 881 | 2.94 / 341.37 | 6 | 65 |
4 | 13 | 1702.08 | 20 | 14.63 | 2724 | 797 | 3.74 / 342.17 | 6 | 69 |
5 | 13 | 865.56 | 20 | 14.75 | 1567 | 462 | 4.20 / 342.63 | 6 | 82 |
6 | 13 | 50.48 | 20 | 14.97 | 390 | 117 | 4.32 / 342.75 | 6 | 73 |
7 | 8 | 0.00 | 272 | 14.93 | 301 | 1222 | 5.54 / 343.97 | 6 | 141 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 26 | 14.94 | 444 | 172 | 0.17 / 333.37 | 6 | 14 |
2 | 7 | 2005.68 | 40 | 14.73 | 3088 | 1819 | 1.99 / 335.19 | 14 | 60 |
3 | 13 | 1626.72 | 20 | 14.71 | 2620 | 771 | 2.76 / 335.96 | 6 | 69 |
4 | 13 | 1538.16 | 20 | 14.66 | 2504 | 734 | 3.50 / 336.70 | 6 | 72 |
5 | 13 | 618.80 | 20 | 14.81 | 1239 | 367 | 3.86 / 337.06 | 6 | 82 |
6 | 13 | 49.68 | 20 | 14.98 | 394 | 118 | 3.98 / 337.18 | 6 | 73 |
7 | 13 | 27.76 | 20 | 14.97 | 355 | 106 | 4.09 / 337.29 | 6 | 72 |
8 | 8 | 0.08 | 248 | 14.93 | 307 | 1137 | 5.22 / 338.42 | 6 | 129 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 26 | 14.96 | 449 | 175 | 0.17 / 328.11 | 6 | 15 |
2 | 7 | 2009.36 | 41 | 14.71 | 3113 | 1877 | 2.05 / 329.99 | 15 | 58 |
3 | 13 | 1922.52 | 20 | 14.68 | 2999 | 881 | 2.93 / 330.87 | 6 | 66 |
4 | 13 | 1258.96 | 20 | 14.72 | 2115 | 623 | 3.56 / 331.49 | 6 | 75 |
5 | 13 | 639.20 | 20 | 14.81 | 1255 | 372 | 3.93 / 331.87 | 6 | 83 |
6 | 13 | 90.60 | 20 | 14.96 | 455 | 136 | 4.06 / 332.00 | 6 | 74 |
7 | 8 | 0.16 | 268 | 14.94 | 299 | 1197 | 5.26 / 333.20 | 6 | 130 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 26 | 14.96 | 452 | 176 | 0.18 / 322.83 | 6 | 14 |
2 | 7 | 2016.04 | 40 | 14.72 | 3121 | 1838 | 2.01 / 324.67 | 14 | 58 |
3 | 13 | 1925.40 | 20 | 14.69 | 3010 | 884 | 2.90 / 325.55 | 6 | 64 |
4 | 13 | 1264.60 | 20 | 14.71 | 2145 | 631 | 3.53 / 326.18 | 6 | 76 |
5 | 13 | 734.08 | 20 | 14.80 | 1398 | 414 | 3.94 / 326.60 | 6 | 83 |
6 | 13 | 42.88 | 20 | 15.00 | 383 | 115 | 4.06 / 326.71 | 6 | 72 |
7 | 8 | 0.40 | 272 | 14.95 | 302 | 1228 | 5.29 / 327.94 | 6 | 129 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 26 | 14.98 | 441 | 172 | 0.17 / 317.44 | 6 | 13 |
2 | 3 | 1024.56 | 1 | 15.14 | 1855 | 28 | 0.20 / 317.46 | 6 | 20 |
3 | 7 | 2008.64 | 40 | 14.73 | 3085 | 1818 | 2.02 / 319.28 | 20 | 59 |
4 | 13 | 1926.68 | 20 | 14.69 | 3007 | 883 | 2.90 / 320.16 | 6 | 64 |
5 | 13 | 1371.28 | 20 | 14.70 | 2273 | 668 | 3.57 / 320.83 | 6 | 76 |
6 | 13 | 814.20 | 20 | 14.78 | 1516 | 448 | 4.02 / 321.28 | 6 | 84 |
7 | 13 | 93.00 | 20 | 14.98 | 455 | 136 | 4.15 / 321.42 | 6 | 76 |
8 | 8 | 0.32 | 272 | 14.95 | 304 | 1236 | 5.39 / 322.65 | 6 | 130 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 25 | 14.99 | 450 | 169 | 0.17 / 312.12 | 6 | 11 |
2 | 7 | 2014.92 | 40 | 14.73 | 3113 | 1834 | 2.00 / 313.95 | 11 | 59 |
3 | 13 | 1918.48 | 20 | 14.70 | 3007 | 884 | 2.89 / 314.84 | 6 | 65 |
4 | 13 | 1262.92 | 20 | 14.73 | 2123 | 625 | 3.51 / 315.46 | 6 | 76 |
5 | 13 | 618.12 | 20 | 14.85 | 1252 | 372 | 3.88 / 315.83 | 6 | 84 |
6 | 13 | 162.16 | 20 | 14.97 | 569 | 170 | 4.05 / 316.00 | 6 | 78 |
7 | 13 | 12.00 | 20 | 15.01 | 334 | 100 | 4.15 / 316.11 | 6 | 73 |
8 | 8 | -0.12 | 249 | 14.96 | 311 | 1158 | 5.31 / 317.26 | 6 | 131 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 25 | 15.01 | 447 | 168 | 0.17 / 306.82 | 6 | 14 |
2 | 7 | 2003.24 | 40 | 14.73 | 3114 | 1835 | 2.00 / 308.66 | 14 | 60 |
3 | 13 | 1914.00 | 20 | 14.69 | 3000 | 881 | 2.88 / 309.54 | 6 | 66 |
4 | 13 | 1265.20 | 20 | 14.74 | 2132 | 629 | 3.51 / 310.17 | 6 | 77 |
5 | 13 | 726.00 | 20 | 14.82 | 1402 | 416 | 3.93 / 310.58 | 6 | 87 |
6 | 13 | 81.28 | 20 | 15.01 | 444 | 133 | 4.06 / 310.72 | 6 | 75 |
7 | 13 | 15.60 | 20 | 15.03 | 334 | 100 | 4.16 / 310.82 | 6 | 75 |
8 | 8 | -0.04 | 250 | 14.98 | 303 | 1135 | 5.30 / 311.95 | 6 | 141 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 27 | 15.01 | 449 | 182 | 0.18 / 301.33 | 6 | 14 |
2 | 3 | 957.28 | -1 | 15.43 | 12 | 0 | 0.00 / 301.33 | 6 | 14 |
3 | 7 | 2012.40 | 40 | 14.73 | 3126 | 1842 | 2.02 / 303.17 | 14 | 60 |
4 | 13 | 1923.36 | 20 | 14.70 | 3022 | 888 | 2.91 / 304.06 | 6 | 65 |
5 | 13 | 1391.60 | 20 | 14.71 | 2332 | 686 | 3.60 / 304.74 | 6 | 77 |
6 | 13 | 958.16 | 20 | 14.75 | 1735 | 512 | 4.11 / 305.25 | 6 | 84 |
7 | 13 | 45.56 | 20 | 15.04 | 399 | 120 | 4.23 / 305.37 | 6 | 73 |
8 | 8 | -0.32 | 272 | 14.99 | 314 | 1280 | 5.51 / 306.65 | 6 | 135 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 25 | 15.02 | 464 | 174 | 0.17 / 296.04 | 6 | 13 |
2 | 10 | 1008.84 | 3 | 15.08 | 1801 | 81 | 0.26 / 296.13 | 6 | 54 |
3 | 3 | 963.64 | -1 | 15.43 | 12 | 0 | 0.08 / 296.13 | 6 | 54 |
4 | 7 | 2013.28 | 40 | 14.73 | 3137 | 1848 | 2.10 / 297.97 | 54 | 60 |
5 | 13 | 1924.16 | 20 | 14.69 | 3017 | 886 | 2.99 / 298.86 | 6 | 66 |
6 | 13 | 1091.72 | 20 | 14.78 | 1906 | 563 | 3.55 / 299.42 | 6 | 78 |
7 | 13 | 578.12 | 20 | 14.88 | 1202 | 358 | 3.91 / 299.78 | 6 | 86 |
8 | 13 | 59.04 | 20 | 15.04 | 413 | 124 | 4.04 / 299.91 | 6 | 74 |
9 | 8 | -0.32 | 267 | 15.00 | 309 | 1238 | 5.27 / 301.14 | 6 | 132 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 26 | 15.03 | 448 | 175 | 0.18 / 290.65 | 6 | 14 |
2 | 7 | 2017.24 | 40 | 14.73 | 3136 | 1848 | 2.02 / 292.50 | 14 | 60 |
3 | 13 | 1919.92 | 20 | 14.70 | 3005 | 883 | 2.91 / 293.38 | 6 | 67 |
4 | 13 | 1467.48 | 20 | 14.70 | 2419 | 711 | 3.62 / 294.09 | 6 | 76 |
5 | 13 | 667.52 | 20 | 14.86 | 1323 | 393 | 4.01 / 294.49 | 6 | 85 |
6 | 13 | 107.00 | 20 | 15.03 | 487 | 146 | 4.16 / 294.63 | 6 | 74 |
7 | 8 | -0.24 | 270 | 15.01 | 305 | 1236 | 5.39 / 295.87 | 6 | 131 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 26 | 15.03 | 449 | 175 | 0.18 / 285.22 | 6 | 14 |
2 | 7 | 2022.28 | 40 | 14.74 | 3159 | 1863 | 2.04 / 287.09 | 14 | 61 |
3 | 13 | 1943.12 | 20 | 14.70 | 3043 | 895 | 2.93 / 287.98 | 6 | 64 |
4 | 13 | 1491.56 | 20 | 14.71 | 2444 | 719 | 3.65 / 288.70 | 6 | 75 |
5 | 13 | 687.48 | 20 | 14.87 | 1347 | 401 | 4.05 / 289.10 | 6 | 85 |
6 | 13 | 69.48 | 20 | 15.06 | 433 | 130 | 4.18 / 289.23 | 6 | 73 |
7 | 8 | -0.36 | 270 | 15.03 | 307 | 1246 | 5.43 / 290.48 | 6 | 139 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 26 | 15.04 | 447 | 175 | 0.17 / 279.88 | 6 | 17 |
2 | 7 | 2012.72 | 40 | 14.75 | 3133 | 1848 | 2.02 / 281.73 | 17 | 61 |
3 | 13 | 1921.04 | 20 | 14.72 | 3014 | 887 | 2.91 / 282.61 | 6 | 66 |
4 | 13 | 1285.92 | 20 | 14.75 | 2175 | 642 | 3.55 / 283.25 | 6 | 78 |
5 | 13 | 724.12 | 20 | 14.86 | 1401 | 416 | 3.97 / 283.67 | 6 | 84 |
6 | 13 | 64.80 | 20 | 15.06 | 425 | 128 | 4.10 / 283.80 | 6 | 72 |
7 | 8 | -0.04 | 270 | 15.03 | 308 | 1250 | 5.35 / 285.05 | 6 | 134 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 25 | 15.06 | 464 | 175 | 0.17 / 274.39 | 6 | 15 |
2 | 10 | 1014.88 | 3 | 15.10 | 1803 | 82 | 0.26 / 274.48 | 6 | 57 |
3 | 3 | 953.56 | -1 | 15.44 | 12 | 0 | 0.08 / 274.48 | 6 | 57 |
4 | 7 | 2010.00 | 40 | 14.74 | 3148 | 1856 | 2.11 / 276.33 | 57 | 61 |
5 | 13 | 1920.84 | 20 | 14.72 | 3020 | 889 | 3.00 / 277.22 | 6 | 66 |
6 | 13 | 1287.92 | 20 | 14.75 | 2174 | 641 | 3.64 / 277.86 | 6 | 79 |
7 | 13 | 760.16 | 20 | 14.86 | 1441 | 428 | 4.07 / 278.29 | 6 | 87 |
8 | 13 | 183.12 | 20 | 15.04 | 598 | 180 | 4.25 / 278.47 | 6 | 80 |
9 | 8 | -0.56 | 266 | 15.03 | 308 | 1231 | 5.48 / 279.70 | 6 | 131 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 27 | 15.06 | 450 | 183 | 0.18 / 269.10 | 6 | 17 |
2 | 3 | 961.52 | -1 | 15.45 | 12 | 0 | 0.00 / 269.10 | 6 | 17 |
3 | 7 | 1999.00 | 40 | 14.76 | 3116 | 1840 | 2.02 / 270.94 | 17 | 61 |
4 | 13 | 1918.16 | 20 | 14.72 | 2994 | 881 | 2.90 / 271.82 | 6 | 64 |
5 | 13 | 1268.56 | 20 | 14.77 | 2140 | 632 | 3.54 / 272.45 | 6 | 80 |
6 | 13 | 739.28 | 20 | 14.88 | 1414 | 421 | 3.96 / 272.87 | 6 | 85 |
7 | 13 | 42.24 | 20 | 15.09 | 377 | 114 | 4.07 / 272.98 | 6 | 73 |
8 | 8 | 0.20 | 270 | 15.05 | 304 | 1235 | 5.31 / 274.22 | 6 | 131 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 27 | 15.08 | 456 | 186 | 0.19 / 263.59 | 6 | 19 |
2 | 7 | 2012.04 | 40 | 14.75 | 3135 | 1850 | 2.04 / 265.43 | 19 | 62 |
3 | 13 | 1942.48 | 20 | 14.71 | 3030 | 891 | 2.93 / 266.33 | 6 | 66 |
4 | 13 | 1411.16 | 20 | 14.73 | 2349 | 692 | 3.62 / 267.02 | 6 | 78 |
5 | 13 | 746.88 | 20 | 14.88 | 1421 | 423 | 4.04 / 267.44 | 6 | 86 |
6 | 13 | 269.40 | 20 | 15.02 | 737 | 221 | 4.26 / 267.66 | 6 | 83 |
7 | 13 | 24.20 | 20 | 15.09 | 354 | 107 | 4.37 / 267.77 | 6 | 75 |
8 | 8 | 0.08 | 246 | 15.05 | 309 | 1144 | 5.51 / 268.91 | 6 | 131 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 25 | 15.08 | 467 | 176 | 0.18 / 258.18 | 6 | 14 |
2 | 3 | 1076.64 | 2 | 15.14 | 1899 | 58 | 0.23 / 258.24 | 6 | 55 |
3 | 7 | 2013.60 | 41 | 14.75 | 3140 | 1899 | 2.13 / 260.13 | 55 | 60 |
4 | 13 | 1939.40 | 20 | 14.72 | 3025 | 891 | 3.02 / 261.03 | 6 | 65 |
5 | 13 | 1478.40 | 20 | 14.73 | 2430 | 716 | 3.74 / 261.74 | 6 | 76 |
6 | 13 | 562.44 | 20 | 14.95 | 1162 | 347 | 4.09 / 262.09 | 6 | 87 |
7 | 13 | 34.32 | 20 | 15.12 | 364 | 110 | 4.20 / 262.20 | 6 | 72 |
8 | 8 | 0.04 | 263 | 15.07 | 303 | 1201 | 5.40 / 263.40 | 6 | 137 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 26 | 15.08 | 443 | 174 | 0.17 / 252.88 | 6 | 16 |
2 | 3 | 963.08 | -1 | 15.46 | 12 | 0 | 0.00 / 252.88 | 6 | 16 |
3 | 7 | 2013.08 | 40 | 14.76 | 3118 | 1841 | 2.01 / 254.72 | 16 | 59 |
4 | 13 | 1921.32 | 20 | 14.73 | 2985 | 879 | 2.89 / 255.60 | 6 | 64 |
5 | 13 | 1365.28 | 20 | 14.77 | 2260 | 668 | 3.56 / 256.27 | 6 | 76 |
6 | 13 | 692.44 | 20 | 14.91 | 1341 | 400 | 3.96 / 256.66 | 6 | 87 |
7 | 13 | 60.16 | 20 | 15.11 | 408 | 123 | 4.08 / 256.79 | 6 | 72 |
8 | 8 | 0.04 | 265 | 15.07 | 304 | 1214 | 5.30 / 258.00 | 6 | 132 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 26 | 15.09 | 459 | 180 | 0.18 / 247.59 | 6 | 20 |
2 | 7 | 2008.64 | 40 | 14.77 | 3131 | 1850 | 2.03 / 249.44 | 20 | 62 |
3 | 13 | 1923.36 | 20 | 14.74 | 3006 | 886 | 2.92 / 250.33 | 6 | 63 |
4 | 13 | 1282.88 | 20 | 14.80 | 2149 | 636 | 3.55 / 250.96 | 6 | 76 |
5 | 13 | 637.40 | 20 | 14.94 | 1271 | 380 | 3.93 / 251.34 | 6 | 85 |
6 | 13 | 46.84 | 20 | 15.12 | 384 | 116 | 4.05 / 251.46 | 6 | 74 |
7 | 8 | -0.04 | 270 | 15.08 | 306 | 1246 | 5.29 / 252.70 | 6 | 133 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 26 | 15.10 | 456 | 179 | 0.18 / 242.09 | 6 | 19 |
2 | 7 | 2008.04 | 40 | 14.78 | 3119 | 1844 | 2.02 / 243.94 | 12 | 59 |
3 | 13 | 1920.52 | 20 | 14.75 | 3007 | 887 | 2.91 / 244.82 | 6 | 66 |
4 | 13 | 1469.04 | 20 | 14.76 | 2420 | 714 | 3.62 / 245.54 | 6 | 74 |
5 | 13 | 899.44 | 20 | 14.87 | 1648 | 490 | 4.11 / 246.03 | 6 | 82 |
6 | 13 | 92.48 | 20 | 15.12 | 470 | 142 | 4.26 / 246.17 | 6 | 75 |
7 | 8 | 0.08 | 261 | 15.08 | 315 | 1240 | 5.50 / 247.41 | 6 | 132 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 26 | 15.10 | 446 | 175 | 0.18 / 236.81 | 6 | 19 |
2 | 7 | 2005.44 | 41 | 14.79 | 3087 | 1872 | 2.05 / 238.69 | 19 | 62 |
3 | 13 | 1910.32 | 20 | 14.76 | 2976 | 879 | 2.93 / 239.56 | 6 | 66 |
4 | 13 | 1249.52 | 20 | 14.82 | 2094 | 621 | 3.55 / 240.18 | 6 | 77 |
5 | 13 | 589.36 | 20 | 14.98 | 1203 | 360 | 3.91 / 240.54 | 6 | 86 |
6 | 13 | 58.64 | 20 | 15.13 | 412 | 125 | 4.03 / 240.67 | 6 | 74 |
7 | 8 | 0.00 | 270 | 15.10 | 305 | 1243 | 5.27 / 241.91 | 6 | 136 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 26 | 15.11 | 450 | 177 | 0.18 / 231.45 | 6 | 20 |
2 | 7 | 2015.64 | 41 | 14.77 | 3135 | 1898 | 2.08 / 233.35 | 20 | 61 |
3 | 13 | 1931.44 | 20 | 14.74 | 3040 | 896 | 2.97 / 234.25 | 6 | 67 |
4 | 13 | 1290.32 | 20 | 14.81 | 2168 | 642 | 3.61 / 234.89 | 6 | 79 |
5 | 13 | 731.56 | 20 | 14.94 | 1402 | 419 | 4.03 / 235.31 | 6 | 85 |
6 | 13 | 33.16 | 20 | 15.15 | 368 | 112 | 4.14 / 235.42 | 6 | 73 |
7 | 8 | 0.04 | 261 | 15.10 | 309 | 1218 | 5.36 / 236.64 | 6 | 131 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 26 | 15.11 | 454 | 178 | 0.18 / 225.93 | 6 | 22 |
2 | 7 | 2007.16 | 40 | 14.79 | 3120 | 1846 | 2.02 / 227.78 | 22 | 62 |
3 | 13 | 1935.80 | 20 | 14.75 | 3051 | 900 | 2.92 / 228.68 | 6 | 64 |
4 | 13 | 1375.40 | 20 | 14.81 | 2283 | 676 | 3.60 / 229.36 | 6 | 77 |
5 | 13 | 1028.20 | 20 | 14.86 | 1798 | 534 | 4.13 / 229.89 | 6 | 85 |
6 | 13 | 182.16 | 20 | 15.11 | 587 | 177 | 4.31 / 230.07 | 6 | 83 |
7 | 8 | 0.00 | 259 | 15.10 | 309 | 1208 | 5.52 / 231.28 | 6 | 130 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 26 | 15.12 | 458 | 180 | 0.18 / 220.54 | 6 | 22 |
2 | 7 | 2004.20 | 40 | 14.79 | 3107 | 1838 | 2.02 / 222.38 | 22 | 60 |
3 | 13 | 1916.84 | 20 | 14.75 | 3008 | 887 | 2.91 / 223.27 | 6 | 65 |
4 | 13 | 1475.80 | 20 | 14.79 | 2422 | 716 | 3.62 / 223.98 | 6 | 77 |
5 | 13 | 673.52 | 20 | 14.98 | 1315 | 394 | 4.02 / 224.38 | 6 | 88 |
6 | 13 | 106.96 | 20 | 15.14 | 494 | 150 | 4.17 / 224.53 | 6 | 79 |
7 | 8 | 0.08 | 259 | 15.11 | 314 | 1229 | 5.39 / 225.76 | 6 | 130 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 26 | 15.13 | 468 | 184 | 0.18 / 214.98 | 6 | 22 |
2 | 3 | 1028.20 | 1 | 15.18 | 1852 | 28 | 0.21 / 215.01 | 6 | 33 |
3 | 7 | 2020.36 | 40 | 14.79 | 3123 | 1848 | 2.06 / 216.85 | 33 | 62 |
4 | 13 | 1934.96 | 20 | 14.75 | 3010 | 888 | 2.95 / 217.74 | 6 | 68 |
5 | 13 | 1378.72 | 20 | 14.81 | 2307 | 683 | 3.63 / 218.43 | 6 | 78 |
6 | 13 | 1057.12 | 20 | 14.86 | 1849 | 550 | 4.18 / 218.97 | 6 | 82 |
7 | 13 | 55.28 | 20 | 15.16 | 414 | 126 | 4.31 / 219.10 | 6 | 76 |
8 | 8 | 0.08 | 264 | 15.12 | 316 | 1261 | 5.57 / 220.36 | 6 | 130 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 26 | 15.13 | 454 | 179 | 0.18 / 209.55 | 6 | 19 |
2 | 7 | 2015.68 | 40 | 14.80 | 3118 | 1846 | 2.02 / 211.39 | 19 | 61 |
3 | 13 | 1932.96 | 20 | 14.77 | 3015 | 891 | 2.92 / 212.28 | 6 | 65 |
4 | 13 | 1281.60 | 20 | 14.85 | 2171 | 645 | 3.56 / 212.93 | 6 | 78 |
5 | 13 | 830.84 | 20 | 14.94 | 1541 | 460 | 4.02 / 213.39 | 6 | 86 |
6 | 13 | 31.32 | 20 | 15.17 | 384 | 117 | 4.14 / 213.50 | 6 | 76 |
7 | 8 | -0.12 | 268 | 15.13 | 318 | 1289 | 5.43 / 214.79 | 6 | 131 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 26 | 15.14 | 460 | 181 | 0.18 / 203.92 | 6 | 20 |
2 | 10 | 1036.28 | 3 | 15.16 | 1833 | 83 | 0.26 / 204.00 | 6 | 62 |
3 | 3 | 952.40 | -1 | 15.48 | 12 | 0 | 0.08 / 204.00 | 6 | 62 |
4 | 7 | 2009.20 | 40 | 14.79 | 3150 | 1864 | 2.13 / 205.86 | 62 | 61 |
5 | 13 | 1925.84 | 20 | 14.75 | 3037 | 896 | 3.02 / 206.76 | 6 | 66 |
6 | 13 | 1489.88 | 20 | 14.79 | 2462 | 728 | 3.75 / 207.49 | 6 | 78 |
7 | 13 | 928.08 | 20 | 14.92 | 1673 | 499 | 4.25 / 207.99 | 6 | 86 |
8 | 13 | 46.60 | 20 | 15.17 | 401 | 122 | 4.37 / 208.11 | 6 | 76 |
9 | 8 | -0.04 | 261 | 15.13 | 319 | 1260 | 5.63 / 209.37 | 6 | 134 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 26 | 15.14 | 457 | 180 | 0.18 / 198.62 | 6 | 20 |
2 | 7 | 2006.56 | 40 | 14.80 | 3127 | 1851 | 2.03 / 200.47 | 20 | 60 |
3 | 13 | 1924.40 | 20 | 14.78 | 3001 | 887 | 2.92 / 201.36 | 6 | 66 |
4 | 13 | 1192.44 | 20 | 14.89 | 2039 | 607 | 3.53 / 201.96 | 6 | 79 |
5 | 13 | 657.88 | 20 | 15.00 | 1305 | 391 | 3.92 / 202.35 | 6 | 86 |
6 | 13 | 103.12 | 20 | 15.16 | 483 | 146 | 4.06 / 202.50 | 6 | 77 |
7 | 8 | 0.08 | 263 | 15.14 | 310 | 1234 | 5.30 / 203.73 | 6 | 131 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 26 | 15.15 | 460 | 181 | 0.18 / 193.30 | 6 | 21 |
2 | 7 | 2012.60 | 40 | 14.81 | 3113 | 1844 | 2.03 / 195.14 | 12 | 63 |
3 | 13 | 1926.76 | 20 | 14.79 | 2996 | 886 | 2.91 / 196.03 | 6 | 66 |
4 | 13 | 1304.76 | 20 | 14.87 | 2185 | 650 | 3.56 / 196.68 | 6 | 76 |
5 | 13 | 631.40 | 20 | 15.02 | 1262 | 379 | 3.94 / 197.06 | 6 | 87 |
6 | 13 | 85.80 | 20 | 15.18 | 462 | 140 | 4.08 / 197.20 | 6 | 78 |
7 | 8 | -0.04 | 261 | 15.15 | 313 | 1238 | 5.32 / 198.44 | 6 | 133 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 27 | 15.17 | 463 | 190 | 0.19 / 187.85 | 6 | 21 |
2 | 10 | 1015.48 | 2 | 15.15 | 1808 | 55 | 0.24 / 187.90 | 6 | 56 |
3 | 3 | 943.96 | -1 | 15.49 | 13 | 0 | 0.05 / 187.90 | 6 | 56 |
4 | 7 | 2007.64 | 40 | 14.81 | 3138 | 1859 | 2.10 / 189.76 | 56 | 61 |
5 | 13 | 1941.68 | 20 | 14.79 | 3025 | 895 | 3.00 / 190.66 | 6 | 65 |
6 | 13 | 1419.48 | 20 | 14.83 | 2340 | 694 | 3.69 / 191.35 | 6 | 76 |
7 | 13 | 740.92 | 20 | 15.00 | 1419 | 426 | 4.12 / 191.78 | 6 | 86 |
8 | 13 | 77.60 | 20 | 15.19 | 432 | 131 | 4.25 / 191.91 | 6 | 77 |
9 | 8 | -0.16 | 261 | 15.15 | 306 | 1210 | 5.46 / 193.12 | 6 | 135 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 26 | 15.17 | 454 | 179 | 0.18 / 182.51 | 6 | 19 |
2 | 10 | 1007.44 | 3 | 15.14 | 1808 | 82 | 0.26 / 182.60 | 6 | 54 |
3 | 3 | 938.56 | -1 | 15.49 | 13 | 0 | 0.08 / 182.60 | 6 | 54 |
4 | 7 | 2005.28 | 40 | 14.81 | 3133 | 1856 | 2.12 / 184.45 | 54 | 61 |
5 | 13 | 1934.52 | 20 | 14.80 | 3018 | 893 | 3.01 / 185.35 | 6 | 66 |
6 | 13 | 1302.00 | 20 | 14.88 | 2171 | 646 | 3.66 / 185.99 | 6 | 78 |
7 | 13 | 544.52 | 20 | 15.06 | 1132 | 341 | 4.00 / 186.33 | 6 | 86 |
8 | 13 | 59.76 | 20 | 15.20 | 408 | 124 | 4.12 / 186.46 | 6 | 74 |
9 | 8 | -0.44 | 261 | 15.16 | 304 | 1203 | 5.32 / 187.66 | 6 | 131 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 27 | 15.16 | 457 | 187 | 0.19 / 177.02 | 6 | 23 |
2 | 3 | 963.40 | -1 | 15.50 | 13 | 0 | 0.00 / 177.02 | 6 | 23 |
3 | 7 | 2008.24 | 40 | 14.82 | 3128 | 1854 | 2.04 / 178.88 | 23 | 60 |
4 | 13 | 1931.84 | 20 | 14.80 | 3017 | 893 | 2.93 / 179.77 | 6 | 66 |
5 | 13 | 1474.92 | 20 | 14.83 | 2426 | 720 | 3.65 / 180.49 | 6 | 75 |
6 | 13 | 937.48 | 20 | 14.95 | 1663 | 497 | 4.15 / 180.99 | 6 | 80 |
7 | 13 | 52.84 | 20 | 15.21 | 399 | 121 | 4.27 / 181.11 | 6 | 75 |
8 | 8 | -0.28 | 263 | 15.17 | 308 | 1229 | 5.50 / 182.34 | 6 | 136 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 26 | 15.18 | 464 | 183 | 0.18 / 171.37 | 6 | 19 |
2 | 3 | 1025.56 | 1 | 15.21 | 1857 | 28 | 0.21 / 171.40 | 6 | 25 |
3 | 7 | 2007.80 | 40 | 14.83 | 3101 | 1840 | 2.05 / 173.24 | 25 | 61 |
4 | 13 | 1925.44 | 20 | 14.81 | 2983 | 884 | 2.93 / 174.12 | 6 | 67 |
5 | 13 | 1477.44 | 20 | 14.85 | 2399 | 713 | 3.65 / 174.83 | 6 | 75 |
6 | 13 | 996.04 | 20 | 14.94 | 1752 | 523 | 4.17 / 175.36 | 6 | 85 |
7 | 13 | 386.96 | 20 | 15.10 | 900 | 272 | 4.44 / 175.63 | 6 | 90 |
8 | 8 | 0.08 | 259 | 15.16 | 307 | 1205 | 5.65 / 176.83 | 6 | 135 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 25 | 15.18 | 451 | 171 | 0.17 / 165.97 | 6 | 18 |
2 | 3 | 1061.36 | 2 | 15.18 | 1868 | 57 | 0.23 / 166.03 | 6 | 56 |
3 | 7 | 2007.28 | 40 | 14.83 | 3121 | 1851 | 2.08 / 167.88 | 56 | 62 |
4 | 13 | 1924.08 | 20 | 14.80 | 3015 | 892 | 2.97 / 168.77 | 6 | 66 |
5 | 13 | 1367.76 | 20 | 14.88 | 2270 | 676 | 3.65 / 169.45 | 6 | 78 |
6 | 13 | 782.00 | 20 | 15.00 | 1460 | 438 | 4.09 / 169.88 | 6 | 88 |
7 | 13 | 47.68 | 20 | 15.21 | 388 | 118 | 4.20 / 170.00 | 6 | 77 |
8 | 8 | 0.12 | 255 | 15.18 | 306 | 1184 | 5.39 / 171.19 | 6 | 135 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 27 | 15.18 | 446 | 183 | 0.18 / 160.74 | 6 | 18 |
2 | 3 | 957.24 | -1 | 15.51 | 12 | 0 | 0.00 / 160.74 | 6 | 18 |
3 | 7 | 2010.68 | 40 | 14.83 | 3099 | 1838 | 2.02 / 162.57 | 18 | 61 |
4 | 13 | 1911.76 | 20 | 14.81 | 2982 | 883 | 2.90 / 163.46 | 6 | 67 |
5 | 13 | 1237.16 | 20 | 14.91 | 2065 | 616 | 3.52 / 164.07 | 6 | 78 |
6 | 13 | 678.92 | 20 | 15.04 | 1318 | 396 | 3.92 / 164.47 | 6 | 88 |
7 | 13 | 37.52 | 20 | 15.22 | 371 | 113 | 4.03 / 164.58 | 6 | 75 |
8 | 8 | 0.04 | 261 | 15.17 | 307 | 1216 | 5.25 / 165.80 | 6 | 137 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 27 | 15.19 | 468 | 192 | 0.19 / 155.36 | 6 | 16 |
2 | 7 | 2012.96 | 41 | 14.82 | 3125 | 1899 | 2.09 / 157.26 | 16 | 62 |
3 | 13 | 1920.56 | 20 | 14.81 | 3012 | 892 | 2.98 / 158.15 | 6 | 67 |
4 | 13 | 1184.40 | 20 | 14.92 | 2023 | 604 | 3.59 / 158.76 | 6 | 81 |
5 | 13 | 830.36 | 20 | 14.99 | 1549 | 464 | 4.05 / 159.22 | 6 | 86 |
6 | 13 | 29.92 | 20 | 15.23 | 360 | 110 | 4.16 / 159.33 | 6 | 75 |
7 | 8 | 0.00 | 261 | 15.18 | 309 | 1224 | 5.38 / 160.55 | 6 | 133 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 25 | 15.19 | 444 | 169 | 0.17 / 150.04 | 6 | 13 |
2 | 10 | 1026.56 | 3 | 15.17 | 1845 | 84 | 0.25 / 150.12 | 6 | 52 |
3 | 7 | 2027.36 | 40 | 14.82 | 3137 | 1860 | 2.11 / 151.98 | 52 | 64 |
4 | 13 | 1944.56 | 20 | 14.81 | 3030 | 897 | 3.01 / 152.88 | 6 | 67 |
5 | 13 | 1178.76 | 20 | 14.94 | 1992 | 595 | 3.60 / 153.47 | 6 | 80 |
6 | 13 | 632.88 | 20 | 15.06 | 1260 | 380 | 3.98 / 153.85 | 6 | 88 |
7 | 13 | 39.96 | 20 | 15.23 | 371 | 113 | 4.10 / 153.97 | 6 | 76 |
8 | 8 | 0.08 | 261 | 15.19 | 303 | 1201 | 5.30 / 155.17 | 6 | 133 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 27 | 15.20 | 437 | 179 | 0.18 / 144.80 | 6 | 17 |
2 | 3 | 962.16 | -1 | 15.52 | 12 | 0 | 0.00 / 144.80 | 6 | 17 |
3 | 7 | 2004.56 | 40 | 14.84 | 3100 | 1840 | 2.02 / 146.64 | 17 | 62 |
4 | 13 | 1803.76 | 20 | 14.84 | 2861 | 849 | 2.87 / 147.49 | 6 | 70 |
5 | 13 | 1377.16 | 20 | 14.89 | 2293 | 683 | 3.55 / 148.17 | 6 | 77 |
6 | 13 | 566.60 | 20 | 15.08 | 1165 | 351 | 3.90 / 148.52 | 6 | 89 |
7 | 13 | 58.44 | 20 | 15.23 | 402 | 122 | 4.03 / 148.65 | 6 | 75 |
8 | 8 | -0.84 | 265 | 15.19 | 304 | 1224 | 5.25 / 149.87 | 6 | 130 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 27 | 15.20 | 454 | 186 | 0.19 / 139.66 | 6 | 14 |
2 | 7 | 2006.76 | 40 | 14.86 | 3087 | 1835 | 2.02 / 141.49 | 14 | 61 |
3 | 13 | 1807.72 | 20 | 14.85 | 2854 | 848 | 2.87 / 142.34 | 6 | 69 |
4 | 13 | 1259.20 | 20 | 14.93 | 2107 | 629 | 3.50 / 142.97 | 6 | 80 |
5 | 13 | 514.00 | 20 | 15.11 | 1096 | 331 | 3.83 / 143.30 | 6 | 88 |
6 | 13 | 44.96 | 20 | 15.24 | 387 | 118 | 3.95 / 143.42 | 6 | 75 |
7 | 8 | 0.40 | 259 | 15.20 | 305 | 1201 | 5.15 / 144.62 | 6 | 129 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 27 | 15.20 | 459 | 188 | 0.19 / 134.45 | 6 | 14 |
2 | 7 | 2012.76 | 40 | 14.85 | 3086 | 1833 | 2.02 / 136.29 | 14 | 62 |
3 | 13 | 1917.36 | 20 | 14.83 | 2982 | 884 | 2.91 / 137.17 | 6 | 68 |
4 | 13 | 1255.12 | 20 | 14.93 | 2097 | 626 | 3.53 / 137.80 | 6 | 81 |
5 | 13 | 611.76 | 20 | 15.08 | 1218 | 367 | 3.90 / 138.17 | 6 | 88 |
6 | 13 | 58.40 | 20 | 15.23 | 402 | 122 | 4.02 / 138.29 | 6 | 76 |
7 | 8 | 0.20 | 259 | 15.20 | 301 | 1185 | 5.21 / 139.47 | 6 | 141 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 27 | 15.19 | 460 | 189 | 0.19 / 129.13 | 6 | 17 |
2 | 7 | 2004.28 | 40 | 14.86 | 3086 | 1834 | 2.02 / 130.97 | 10 | 61 |
3 | 13 | 1803.36 | 20 | 14.86 | 2839 | 844 | 2.87 / 131.81 | 6 | 70 |
4 | 13 | 1289.60 | 20 | 14.92 | 2150 | 642 | 3.51 / 132.45 | 6 | 82 |
5 | 13 | 826.60 | 20 | 15.02 | 1514 | 455 | 3.96 / 132.91 | 6 | 88 |
6 | 13 | 49.32 | 20 | 15.24 | 394 | 120 | 4.08 / 133.03 | 6 | 78 |
7 | 8 | -0.88 | 266 | 15.20 | 306 | 1237 | 5.32 / 134.27 | 6 | 137 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 27 | 15.20 | 462 | 190 | 0.19 / 123.63 | 6 | 13 |
2 | 7 | 2009.60 | 40 | 14.86 | 3087 | 1835 | 2.02 / 125.46 | 13 | 62 |
3 | 13 | 1920.04 | 20 | 14.83 | 2992 | 887 | 2.91 / 126.35 | 6 | 67 |
4 | 13 | 1363.32 | 20 | 14.91 | 2259 | 674 | 3.59 / 127.03 | 6 | 80 |
5 | 13 | 890.12 | 20 | 15.01 | 1603 | 481 | 4.07 / 127.51 | 6 | 86 |
6 | 13 | 162.96 | 20 | 15.20 | 574 | 174 | 4.24 / 127.68 | 6 | 86 |
7 | 13 | 28.36 | 20 | 15.23 | 361 | 110 | 4.35 / 127.79 | 6 | 79 |
8 | 8 | -0.44 | 246 | 15.19 | 309 | 1155 | 5.51 / 128.95 | 6 | 138 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 27 | 15.21 | 443 | 182 | 0.18 / 118.24 | 6 | 14 |
2 | 7 | 2005.44 | 41 | 14.86 | 3092 | 1884 | 2.07 / 120.12 | 14 | 64 |
3 | 13 | 1814.72 | 20 | 14.86 | 2860 | 850 | 2.92 / 120.97 | 6 | 70 |
4 | 13 | 1366.12 | 20 | 14.91 | 2269 | 677 | 3.59 / 121.65 | 6 | 81 |
5 | 13 | 722.16 | 20 | 15.05 | 1384 | 417 | 4.01 / 122.06 | 6 | 88 |
6 | 13 | 41.20 | 20 | 15.25 | 385 | 117 | 4.13 / 122.18 | 6 | 76 |
7 | 8 | 0.48 | 268 | 15.20 | 309 | 1259 | 5.39 / 123.44 | 6 | 132 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 27 | 15.22 | 443 | 182 | 0.18 / 112.90 | 6 | 12 |
2 | 7 | 2005.32 | 40 | 14.87 | 3080 | 1832 | 2.01 / 114.73 | 12 | 63 |
3 | 13 | 1909.00 | 20 | 14.86 | 2980 | 886 | 2.90 / 115.62 | 6 | 67 |
4 | 13 | 1453.92 | 20 | 14.90 | 2384 | 710 | 3.61 / 116.33 | 6 | 78 |
5 | 13 | 637.60 | 20 | 15.09 | 1264 | 381 | 3.99 / 116.71 | 6 | 88 |
6 | 13 | 42.76 | 20 | 15.25 | 383 | 117 | 4.11 / 116.83 | 6 | 75 |
7 | 8 | 0.04 | 265 | 15.21 | 304 | 1225 | 5.33 / 118.05 | 6 | 133 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 27 | 15.22 | 453 | 186 | 0.19 / 107.66 | 6 | 14 |
2 | 7 | 2012.84 | 40 | 14.88 | 3090 | 1839 | 2.03 / 109.50 | 14 | 62 |
3 | 13 | 1917.72 | 20 | 14.85 | 2996 | 890 | 2.92 / 110.39 | 6 | 67 |
4 | 13 | 1140.88 | 20 | 14.99 | 1945 | 583 | 3.50 / 110.97 | 6 | 82 |
5 | 13 | 721.80 | 20 | 15.06 | 1386 | 417 | 3.92 / 111.39 | 6 | 89 |
6 | 13 | 34.12 | 20 | 15.26 | 361 | 110 | 4.03 / 111.50 | 6 | 75 |
7 | 8 | 0.36 | 267 | 15.22 | 300 | 1219 | 5.25 / 112.72 | 6 | 140 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 27 | 15.22 | 453 | 186 | 0.19 / 102.40 | 6 | 14 |
2 | 7 | 2006.08 | 40 | 14.88 | 3078 | 1832 | 2.02 / 104.23 | 6 | 61 |
3 | 13 | 1909.24 | 20 | 14.86 | 2986 | 887 | 2.91 / 105.12 | 6 | 66 |
4 | 13 | 1331.40 | 20 | 14.94 | 2207 | 659 | 3.57 / 105.78 | 6 | 79 |
5 | 13 | 579.56 | 20 | 15.12 | 1184 | 358 | 3.92 / 106.14 | 6 | 87 |
6 | 13 | 51.40 | 20 | 15.26 | 388 | 118 | 4.04 / 106.25 | 6 | 75 |
7 | 8 | -0.48 | 265 | 15.22 | 303 | 1222 | 5.26 / 107.48 | 6 | 129 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 27 | 15.23 | 449 | 185 | 0.18 / 97.18 | 6 | 15 |
2 | 7 | 2004.76 | 41 | 14.88 | 3094 | 1888 | 2.07 / 99.07 | 15 | 60 |
3 | 13 | 1907.20 | 20 | 14.87 | 2980 | 886 | 2.96 / 99.96 | 6 | 65 |
4 | 13 | 1034.40 | 20 | 15.02 | 1806 | 543 | 3.50 / 100.50 | 6 | 81 |
5 | 13 | 706.92 | 20 | 15.08 | 1360 | 410 | 3.91 / 100.91 | 6 | 86 |
6 | 13 | 50.32 | 20 | 15.26 | 383 | 117 | 4.03 / 101.03 | 6 | 75 |
7 | 8 | 0.44 | 259 | 15.22 | 301 | 1187 | 5.21 / 102.21 | 6 | 135 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 27 | 15.23 | 457 | 188 | 0.19 / 91.95 | 6 | 14 |
2 | 7 | 2011.24 | 40 | 14.89 | 3084 | 1837 | 2.02 / 93.79 | 7 | 62 |
3 | 13 | 1925.56 | 20 | 14.87 | 2987 | 888 | 2.91 / 94.68 | 6 | 67 |
4 | 13 | 1153.44 | 20 | 15.00 | 1948 | 584 | 3.50 / 95.26 | 6 | 79 |
5 | 13 | 707.12 | 20 | 15.08 | 1355 | 409 | 3.91 / 95.67 | 6 | 87 |
6 | 13 | 51.40 | 20 | 15.27 | 380 | 116 | 4.02 / 95.79 | 6 | 72 |
7 | 8 | 0.20 | 268 | 15.23 | 297 | 1212 | 5.23 / 97.00 | 6 | 134 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 27 | 15.23 | 464 | 191 | 0.19 / 86.71 | 6 | 13 |
2 | 7 | 2005.80 | 40 | 14.89 | 3082 | 1836 | 2.03 / 88.55 | 13 | 61 |
3 | 13 | 1814.64 | 20 | 14.90 | 2843 | 847 | 2.87 / 89.39 | 6 | 68 |
4 | 13 | 1361.12 | 20 | 14.95 | 2239 | 669 | 3.54 / 90.06 | 6 | 78 |
5 | 13 | 664.40 | 20 | 15.10 | 1302 | 393 | 3.94 / 90.46 | 6 | 86 |
6 | 13 | 39.36 | 20 | 15.27 | 368 | 112 | 4.05 / 90.57 | 6 | 72 |
7 | 8 | 0.00 | 259 | 15.23 | 303 | 1195 | 5.24 / 91.76 | 6 | 134 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 27 | 15.23 | 442 | 182 | 0.18 / 81.42 | 6 | 16 |
2 | 7 | 2014.64 | 40 | 14.89 | 3125 | 1861 | 2.04 / 83.28 | 16 | 60 |
3 | 13 | 1918.40 | 20 | 14.89 | 2997 | 893 | 2.94 / 84.17 | 6 | 67 |
4 | 13 | 1245.32 | 20 | 14.98 | 2108 | 632 | 3.57 / 84.81 | 6 | 79 |
5 | 13 | 578.68 | 20 | 15.13 | 1185 | 359 | 3.93 / 85.16 | 6 | 87 |
6 | 13 | 61.16 | 20 | 15.27 | 406 | 124 | 4.05 / 85.29 | 6 | 75 |
7 | 8 | 0.36 | 265 | 15.23 | 305 | 1231 | 5.28 / 86.52 | 6 | 130 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 27 | 15.25 | 461 | 190 | 0.19 / 76.24 | 6 | 18 |
2 | 7 | 2000.72 | 40 | 14.90 | 3116 | 1857 | 2.05 / 78.09 | 18 | 63 |
3 | 13 | 1908.64 | 20 | 14.89 | 3002 | 894 | 2.94 / 78.99 | 6 | 66 |
4 | 13 | 1223.72 | 20 | 14.99 | 2063 | 618 | 3.56 / 79.61 | 6 | 78 |
5 | 13 | 462.76 | 20 | 15.17 | 1014 | 308 | 3.87 / 79.91 | 6 | 87 |
6 | 13 | 35.92 | 20 | 15.28 | 365 | 112 | 3.98 / 80.02 | 6 | 74 |
7 | 8 | -0.04 | 263 | 15.24 | 303 | 1214 | 5.19 / 81.24 | 6 | 130 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 27 | 15.24 | 459 | 189 | 0.19 / 70.96 | 6 | 17 |
2 | 7 | 2008.08 | 40 | 14.92 | 3101 | 1851 | 2.04 / 72.81 | 8 | 61 |
3 | 13 | 1909.88 | 20 | 14.90 | 2970 | 885 | 2.92 / 73.70 | 6 | 65 |
4 | 13 | 1461.24 | 20 | 14.94 | 2381 | 711 | 3.64 / 74.41 | 6 | 76 |
5 | 13 | 447.08 | 20 | 15.18 | 989 | 300 | 3.94 / 74.71 | 6 | 85 |
6 | 13 | 54.48 | 20 | 15.28 | 395 | 121 | 4.06 / 74.83 | 6 | 72 |
7 | 8 | -0.12 | 263 | 15.25 | 303 | 1215 | 5.27 / 76.05 | 6 | 134 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 27 | 15.24 | 463 | 191 | 0.19 / 65.35 | 6 | 17 |
2 | 7 | 2023.60 | 40 | 14.90 | 3142 | 1873 | 2.06 / 67.22 | 17 | 61 |
3 | 13 | 1929.32 | 20 | 14.89 | 3022 | 900 | 2.96 / 68.12 | 6 | 66 |
4 | 13 | 1591.72 | 20 | 14.90 | 2588 | 771 | 3.73 / 68.89 | 6 | 75 |
5 | 13 | 983.72 | 20 | 15.03 | 1734 | 521 | 4.26 / 69.41 | 6 | 82 |
6 | 13 | 76.72 | 20 | 15.28 | 429 | 131 | 4.39 / 69.55 | 6 | 74 |
7 | 8 | 0.72 | 265 | 15.24 | 304 | 1228 | 5.61 / 70.77 | 6 | 131 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 27 | 15.24 | 463 | 191 | 0.19 / 59.99 | 6 | 17 |
2 | 7 | 2011.00 | 40 | 14.91 | 3104 | 1851 | 2.04 / 61.84 | 17 | 62 |
3 | 13 | 1724.44 | 20 | 14.93 | 2739 | 818 | 2.86 / 62.66 | 6 | 69 |
4 | 13 | 1629.40 | 20 | 14.89 | 2621 | 781 | 3.64 / 63.44 | 6 | 72 |
5 | 13 | 578.56 | 20 | 15.14 | 1176 | 356 | 4.00 / 63.80 | 6 | 88 |
6 | 13 | 32.68 | 20 | 15.29 | 359 | 110 | 4.11 / 63.91 | 6 | 72 |
7 | 8 | -0.32 | 270 | 15.24 | 304 | 1251 | 5.36 / 65.16 | 6 | 143 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 27 | 15.25 | 461 | 190 | 0.19 / 54.67 | 6 | 18 |
2 | 7 | 2005.60 | 40 | 14.91 | 3119 | 1860 | 2.05 / 56.53 | 18 | 61 |
3 | 13 | 1916.60 | 20 | 14.90 | 3000 | 894 | 2.94 / 57.42 | 6 | 67 |
4 | 13 | 1350.56 | 20 | 14.96 | 2268 | 679 | 3.62 / 58.10 | 6 | 78 |
5 | 13 | 569.12 | 20 | 15.14 | 1170 | 354 | 3.98 / 58.45 | 6 | 88 |
6 | 13 | 24.80 | 20 | 15.29 | 355 | 109 | 4.09 / 58.56 | 6 | 74 |
7 | 8 | -0.28 | 266 | 15.25 | 306 | 1241 | 5.33 / 59.80 | 6 | 132 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 26 | 15.25 | 453 | 180 | 0.18 / 49.40 | 6 | 19 |
2 | 3 | 1022.40 | 1 | 15.30 | 1849 | 28 | 0.21 / 49.43 | 6 | 14 |
3 | 7 | 2001.96 | 40 | 14.93 | 3077 | 1838 | 2.05 / 51.27 | 14 | 62 |
4 | 13 | 1797.68 | 20 | 14.93 | 2835 | 847 | 2.89 / 52.11 | 6 | 69 |
5 | 13 | 1356.88 | 20 | 14.98 | 2246 | 673 | 3.56 / 52.79 | 6 | 79 |
6 | 13 | 698.48 | 20 | 15.11 | 1356 | 410 | 3.97 / 53.20 | 6 | 86 |
7 | 13 | 29.88 | 20 | 15.30 | 354 | 108 | 4.08 / 53.31 | 6 | 73 |
8 | 8 | 0.96 | 253 | 15.26 | 303 | 1170 | 5.25 / 54.48 | 6 | 139 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 26 | 15.25 | 453 | 180 | 0.18 / 44.10 | 6 | 18 |
2 | 7 | 2003.00 | 40 | 14.93 | 3087 | 1844 | 2.02 / 45.94 | 18 | 61 |
3 | 13 | 1907.32 | 20 | 14.92 | 2967 | 885 | 2.91 / 46.83 | 6 | 67 |
4 | 13 | 1446.04 | 20 | 14.95 | 2361 | 706 | 3.61 / 47.53 | 6 | 78 |
5 | 13 | 642.16 | 20 | 15.13 | 1271 | 385 | 4.00 / 47.92 | 6 | 88 |
6 | 13 | 41.72 | 20 | 15.30 | 374 | 114 | 4.11 / 48.03 | 6 | 72 |
7 | 8 | 0.04 | 257 | 15.26 | 304 | 1192 | 5.31 / 49.22 | 6 | 130 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 26 | 15.25 | 463 | 184 | 0.18 / 38.94 | 6 | 17 |
2 | 7 | 2009.84 | 41 | 14.92 | 3097 | 1894 | 2.08 / 40.83 | 17 | 61 |
3 | 13 | 1690.32 | 20 | 14.96 | 2699 | 808 | 2.89 / 41.64 | 6 | 71 |
4 | 13 | 1064.12 | 20 | 15.04 | 1855 | 558 | 3.44 / 42.20 | 6 | 80 |
5 | 13 | 730.64 | 20 | 15.10 | 1398 | 422 | 3.87 / 42.62 | 6 | 87 |
6 | 13 | 28.52 | 20 | 15.30 | 354 | 108 | 3.97 / 42.73 | 6 | 71 |
7 | 8 | -0.56 | 257 | 15.25 | 303 | 1188 | 5.16 / 43.92 | 6 | 138 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 27 | 15.25 | 450 | 185 | 0.19 / 33.71 | 6 | 19 |
2 | 7 | 2003.76 | 41 | 14.93 | 3094 | 1894 | 2.08 / 35.60 | 19 | 60 |
3 | 13 | 1792.96 | 20 | 14.94 | 2849 | 851 | 2.93 / 36.45 | 6 | 69 |
4 | 13 | 1237.28 | 20 | 15.00 | 2108 | 632 | 3.56 / 37.08 | 6 | 80 |
5 | 13 | 484.24 | 20 | 15.18 | 1049 | 318 | 3.88 / 37.40 | 6 | 86 |
6 | 13 | 25.60 | 20 | 15.30 | 352 | 108 | 3.99 / 37.51 | 6 | 74 |
7 | 8 | 0.08 | 265 | 15.25 | 308 | 1245 | 5.23 / 38.76 | 6 | 132 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 26 | 15.25 | 457 | 181 | 0.18 / 28.35 | 6 | 18 |
2 | 7 | 2022.24 | 40 | 14.92 | 3123 | 1864 | 2.05 / 30.21 | 18 | 61 |
3 | 13 | 1932.92 | 20 | 14.92 | 3010 | 898 | 2.94 / 31.11 | 6 | 65 |
4 | 13 | 1310.88 | 20 | 15.00 | 2176 | 653 | 3.60 / 31.77 | 6 | 79 |
5 | 13 | 738.60 | 20 | 15.11 | 1408 | 425 | 4.02 / 32.19 | 6 | 86 |
6 | 13 | 16.16 | 20 | 15.31 | 333 | 102 | 4.12 / 32.29 | 6 | 71 |
7 | 8 | 1.12 | 263 | 15.26 | 306 | 1228 | 5.35 / 33.52 | 6 | 129 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 26 | 15.25 | 472 | 187 | 0.19 / 23.21 | 6 | 21 |
2 | 7 | 2004.08 | 40 | 14.93 | 3120 | 1863 | 2.05 / 25.07 | 16 | 61 |
3 | 13 | 1804.04 | 20 | 14.94 | 2878 | 860 | 2.91 / 25.93 | 6 | 67 |
4 | 13 | 1159.04 | 20 | 15.03 | 1984 | 596 | 3.51 / 26.53 | 6 | 79 |
5 | 13 | 412.84 | 20 | 15.20 | 946 | 288 | 3.79 / 26.82 | 6 | 84 |
6 | 13 | 36.52 | 20 | 15.30 | 370 | 113 | 3.91 / 26.93 | 6 | 74 |
7 | 8 | 0.04 | 261 | 15.25 | 311 | 1238 | 5.15 / 28.17 | 6 | 130 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 31 | 15.26 | 448 | 212 | 0.21 / 18.03 | 6 | 26 |
2 | 3 | 787.24 | -3 | 15.58 | 12 | 0 | 0.00 / 18.03 | 6 | 26 |
3 | 7 | 2008.04 | 40 | 14.94 | 3105 | 1856 | 2.07 / 19.89 | 26 | 61 |
4 | 13 | 1593.52 | 20 | 14.99 | 2574 | 772 | 2.84 / 20.66 | 6 | 72 |
5 | 13 | 1277.44 | 20 | 15.01 | 2132 | 640 | 3.48 / 21.30 | 6 | 77 |
6 | 13 | 798.52 | 20 | 15.10 | 1487 | 449 | 3.93 / 21.75 | 6 | 86 |
7 | 8 | 0.12 | 272 | 15.26 | 308 | 1278 | 5.21 / 23.02 | 6 | 131 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 26 | 15.26 | 451 | 179 | 0.18 / 13.64 | 6 | 28 |
2 | 7 | 1506.64 | 40 | 15.11 | 2438 | 1474 | 1.65 / 15.11 | 28 | 62 |
3 | 13 | 1421.40 | 20 | 15.08 | 2331 | 703 | 2.36 / 15.82 | 6 | 68 |
4 | 13 | 889.12 | 20 | 15.14 | 1619 | 490 | 2.85 / 16.31 | 6 | 78 |
5 | 13 | 221.56 | 20 | 15.28 | 654 | 200 | 3.05 / 16.51 | 6 | 78 |
6 | 13 | 25.00 | 20 | 15.32 | 349 | 107 | 3.15 / 16.61 | 6 | 73 |
7 | 8 | 0.00 | 259 | 15.28 | 304 | 1203 | 4.36 / 17.82 | 6 | 130 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 25 | 15.25 | 458 | 175 | 0.17 / 9.17 | 6 | 26 |
2 | 7 | 1515.24 | 40 | 15.10 | 2453 | 1482 | 1.66 / 10.65 | 32 | 65 |
3 | 13 | 1445.56 | 20 | 15.09 | 2379 | 718 | 2.37 / 11.37 | 6 | 69 |
4 | 13 | 915.92 | 20 | 15.13 | 1661 | 503 | 2.88 / 11.87 | 6 | 80 |
5 | 13 | 363.28 | 20 | 15.24 | 866 | 264 | 3.14 / 12.13 | 6 | 80 |
6 | 8 | 0.12 | 282 | 15.28 | 308 | 1327 | 4.47 / 13.46 | 6 | 130 |
Average= | 3.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 31 | 15.29 | 455 | 216 | 0.22 / 4.59 | 6 | 28 |
2 | 3 | 756.08 | -4 | 15.59 | 12 | 0 | 0.00 / 4.59 | 6 | 28 |
3 | 7 | 1518.44 | 40 | 15.11 | 2458 | 1486 | 1.70 / 6.08 | 28 | 64 |
4 | 13 | 1430.16 | 20 | 15.09 | 2337 | 705 | 2.41 / 6.78 | 6 | 70 |
5 | 13 | 1209.16 | 20 | 15.08 | 2036 | 614 | 3.02 / 7.40 | 6 | 74 |
6 | 13 | 401.56 | 20 | 15.23 | 914 | 278 | 3.30 / 7.68 | 6 | 83 |
7 | 8 | 0.08 | 282 | 15.27 | 306 | 1318 | 4.62 / 8.99 | 6 | 132 |
Average= | 3.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 31 | 15.47 | 447 | 214 | 0.21 / 1.82 | 6 | 27 |
2 | 3 | 739.44 | -4 | 15.60 | 12 | 0 | 0.00 / 1.82 | 6 | 27 |
3 | 7 | 938.04 | 40 | 15.24 | 1680 | 1024 | 1.24 / 2.85 | 27 | 67 |
4 | 13 | 266.96 | 20 | 15.34 | 722 | 222 | 1.46 / 3.07 | 6 | 79 |
5 | 8 | 0.12 | 280 | 15.33 | 305 | 1309 | 2.77 / 4.38 | 6 | 129 |
Average= | 2.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 84.44 | 30 | 15.62 | 409 | 192 | 0.19 / 0.19 | 6 | 20 |
2 | 7 | 95.20 | 40 | 15.60 | 420 | 262 | 0.45 / 0.45 | 20 | 26 |
3 | 8 | 0.08 | 276 | 15.55 | 269 | 1154 | 1.61 / 1.61 | 6 | 135 |
Average= | 1.61 (KJ/cycle) |