SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 58 | 14.78 | 461 | 395 | 0.40 / 1314.83 | 6 | 59 |
2 | 3 | 860.20 | -2 | 15.26 | 3 | 0 | 0.00 / 1314.83 | 6 | 59 |
3 | 7 | 2011.12 | 40 | 14.59 | 2848 | 1662 | 2.06 / 1316.49 | 59 | 49 |
4 | 13 | 2004.64 | 20 | 14.52 | 2872 | 834 | 2.89 / 1317.33 | 6 | 52 |
5 | 13 | 1936.60 | 20 | 14.46 | 2801 | 810 | 3.70 / 1318.14 | 6 | 54 |
6 | 13 | 1747.44 | 20 | 14.42 | 2586 | 746 | 4.45 / 1318.88 | 6 | 57 |
7 | 13 | 1318.64 | 20 | 14.51 | 2031 | 589 | 5.04 / 1319.47 | 6 | 65 |
8 | 13 | 590.56 | 20 | 14.72 | 1118 | 329 | 5.37 / 1319.80 | 6 | 77 |
9 | 13 | 19.36 | 20 | 14.91 | 353 | 105 | 5.47 / 1319.90 | 6 | 76 |
10 | 8 | -6.64 | 400 | 14.83 | 297 | 1762 | 7.23 / 1321.67 | 6 | 87 |
Average= | 12.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 75 | 14.77 | 459 | 508 | 0.51 / 1307.68 | 6 | 53 |
2 | 3 | 502.96 | -8 | 15.27 | 3 | 0 | 0.00 / 1307.68 | 6 | 53 |
3 | 7 | 2027.36 | 40 | 14.59 | 2849 | 1663 | 2.17 / 1309.34 | 53 | 49 |
4 | 13 | 2026.88 | 20 | 14.52 | 2902 | 843 | 3.01 / 1310.18 | 6 | 50 |
5 | 13 | 1954.36 | 20 | 14.46 | 2822 | 816 | 3.83 / 1311.00 | 6 | 54 |
6 | 13 | 1763.28 | 20 | 14.43 | 2564 | 740 | 4.57 / 1311.74 | 6 | 58 |
7 | 13 | 1143.40 | 20 | 14.56 | 1802 | 525 | 5.09 / 1312.26 | 6 | 68 |
8 | 13 | 725.24 | 20 | 14.67 | 1263 | 371 | 5.47 / 1312.63 | 6 | 71 |
9 | 13 | 101.84 | 20 | 14.87 | 463 | 138 | 5.60 / 1312.77 | 6 | 71 |
10 | 8 | -5.96 | 370 | 14.82 | 303 | 1661 | 7.26 / 1314.43 | 6 | 129 |
Average= | 12.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 69 | 14.77 | 441 | 449 | 0.45 / 1300.12 | 6 | 35 |
2 | 10 | 1029.32 | 5 | 14.77 | 1669 | 123 | 0.57 / 1300.24 | 6 | 53 |
3 | 3 | 1088.12 | 2 | 14.85 | 1791 | 53 | 0.63 / 1300.30 | 6 | 34 |
4 | 7 | 2005.68 | 40 | 14.61 | 2795 | 1633 | 2.26 / 1301.93 | 34 | 47 |
5 | 13 | 2013.20 | 20 | 14.54 | 2869 | 834 | 3.09 / 1302.77 | 6 | 50 |
6 | 13 | 1940.48 | 20 | 14.48 | 2747 | 796 | 3.89 / 1303.56 | 6 | 54 |
7 | 13 | 1633.92 | 20 | 14.47 | 2364 | 684 | 4.57 / 1304.25 | 6 | 58 |
8 | 13 | 1327.72 | 20 | 14.51 | 1990 | 577 | 5.15 / 1304.82 | 6 | 62 |
9 | 13 | 797.56 | 20 | 14.67 | 1302 | 382 | 5.53 / 1305.20 | 6 | 64 |
10 | 13 | 238.84 | 20 | 14.83 | 608 | 180 | 5.71 / 1305.38 | 6 | 67 |
11 | 8 | -6.48 | 400 | 14.82 | 301 | 1784 | 7.50 / 1307.17 | 6 | 97 |
Average= | 12.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 75 | 14.78 | 424 | 470 | 0.47 / 1292.70 | 6 | 45 |
2 | 3 | 793.80 | -3 | 15.26 | 4 | 0 | 0.00 / 1292.70 | 6 | 45 |
3 | 7 | 2024.48 | 40 | 14.60 | 2830 | 1653 | 2.12 / 1294.35 | 45 | 47 |
4 | 13 | 2009.80 | 20 | 14.54 | 2868 | 834 | 2.96 / 1295.18 | 6 | 53 |
5 | 13 | 1939.88 | 20 | 14.47 | 2786 | 806 | 3.76 / 1295.99 | 6 | 53 |
6 | 13 | 1847.00 | 20 | 14.41 | 2676 | 771 | 4.53 / 1296.76 | 6 | 58 |
7 | 13 | 1124.20 | 20 | 14.57 | 1750 | 510 | 5.04 / 1297.27 | 6 | 67 |
8 | 13 | 700.64 | 20 | 14.69 | 1209 | 355 | 5.40 / 1297.63 | 6 | 68 |
9 | 13 | 152.40 | 20 | 14.85 | 517 | 154 | 5.55 / 1297.78 | 6 | 66 |
10 | 13 | 14.68 | 20 | 14.89 | 347 | 103 | 5.66 / 1297.88 | 6 | 65 |
11 | 8 | -3.28 | 400 | 14.81 | 302 | 1789 | 7.45 / 1299.67 | 6 | 126 |
Average= | 12.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 57 | 14.78 | 420 | 354 | 0.35 / 1284.84 | 6 | 19 |
2 | 10 | 1057.40 | 7 | 14.75 | 1550 | 160 | 0.51 / 1285.00 | 6 | 51 |
3 | 10 | 1116.64 | 5 | 14.74 | 1740 | 128 | 0.64 / 1285.13 | 6 | 50 |
4 | 10 | 1155.20 | 4 | 14.70 | 1861 | 109 | 0.75 / 1285.24 | 6 | 45 |
5 | 3 | 1177.12 | 4 | 14.81 | 1867 | 111 | 0.86 / 1285.35 | 6 | 51 |
6 | 7 | 2010.12 | 40 | 14.60 | 2810 | 1641 | 2.50 / 1286.99 | 51 | 49 |
7 | 13 | 2018.76 | 20 | 14.54 | 2833 | 824 | 3.33 / 1287.81 | 6 | 51 |
8 | 13 | 1953.44 | 20 | 14.47 | 2764 | 800 | 4.13 / 1288.61 | 6 | 53 |
9 | 13 | 1764.12 | 20 | 14.44 | 2525 | 729 | 4.86 / 1289.34 | 6 | 57 |
10 | 13 | 1361.12 | 20 | 14.51 | 2026 | 588 | 5.44 / 1289.93 | 6 | 63 |
11 | 13 | 688.72 | 20 | 14.70 | 1179 | 347 | 5.79 / 1290.28 | 6 | 64 |
12 | 13 | 172.00 | 20 | 14.85 | 537 | 159 | 5.95 / 1290.44 | 6 | 65 |
13 | 8 | -5.20 | 400 | 14.82 | 302 | 1790 | 7.74 / 1292.23 | 6 | 93 |
Average= | 12.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 100 | 14.76 | 451 | 666 | 0.67 / 1276.39 | 6 | 54 |
2 | 2 | 215.12 | 27 | 14.92 | 615 | 248 | 0.91 / 1276.64 | 6 | 53 |
3 | 10 | 1046.44 | 8 | 14.78 | 1721 | 203 | 1.12 / 1276.84 | 6 | 55 |
4 | 10 | 1124.24 | 7 | 14.76 | 1782 | 184 | 1.30 / 1277.03 | 6 | 54 |
5 | 10 | 1187.40 | 6 | 14.72 | 1887 | 167 | 1.47 / 1277.19 | 6 | 54 |
6 | 10 | 1228.64 | 4 | 14.72 | 1950 | 115 | 1.58 / 1277.31 | 6 | 49 |
7 | 3 | 1322.72 | 8 | 14.72 | 2032 | 239 | 1.82 / 1277.55 | 6 | 62 |
8 | 7 | 2017.60 | 40 | 14.60 | 2823 | 1649 | 3.47 / 1279.20 | 62 | 49 |
9 | 13 | 2014.08 | 20 | 14.53 | 2897 | 842 | 4.31 / 1280.04 | 6 | 51 |
10 | 13 | 1955.84 | 20 | 14.46 | 2824 | 817 | 5.13 / 1280.85 | 6 | 53 |
11 | 13 | 1874.76 | 20 | 14.41 | 2703 | 779 | 5.91 / 1281.63 | 6 | 56 |
12 | 13 | 1219.12 | 20 | 14.54 | 1883 | 548 | 6.46 / 1282.18 | 6 | 67 |
13 | 13 | 687.08 | 20 | 14.69 | 1212 | 356 | 6.81 / 1282.54 | 6 | 72 |
14 | 13 | 144.32 | 20 | 14.86 | 514 | 153 | 6.96 / 1282.69 | 6 | 71 |
15 | 8 | -6.72 | 400 | 14.82 | 303 | 1796 | 8.76 / 1284.49 | 6 | 100 |
Average= | 12.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 58 | 14.81 | 354 | 304 | 0.30 / 1266.86 | 6 | 7 |
2 | 10 | 1120.16 | 9 | 14.97 | 793 | 107 | 0.41 / 1266.96 | 6 | 29 |
3 | 10 | 1204.84 | 8 | 14.79 | 1425 | 169 | 0.58 / 1267.13 | 6 | 30 |
4 | 10 | 1281.60 | 7 | 14.90 | 1273 | 133 | 0.71 / 1267.26 | 6 | 26 |
5 | 10 | 1345.32 | 6 | 14.71 | 1141 | 101 | 0.81 / 1267.36 | 6 | 42 |
6 | 10 | 1392.24 | 4 | 14.63 | 2157 | 126 | 0.94 / 1267.49 | 6 | 44 |
7 | 3 | 1434.16 | 11 | 15.02 | 536 | 89 | 1.03 / 1267.58 | 6 | 51 |
8 | 7 | 2025.04 | 40 | 14.82 | 2200 | 1304 | 2.33 / 1268.88 | 51 | 33 |
9 | 13 | 2084.24 | 20 | 14.72 | 2344 | 690 | 3.02 / 1269.57 | 6 | 30 |
10 | 13 | 2093.00 | 20 | 14.72 | 1932 | 569 | 3.59 / 1270.14 | 6 | 24 |
11 | 13 | 2038.24 | 20 | 14.55 | 2274 | 662 | 4.25 / 1270.80 | 6 | 31 |
12 | 13 | 1967.88 | 20 | 14.55 | 2124 | 618 | 4.87 / 1271.42 | 6 | 18 |
13 | 13 | 1889.16 | 20 | 14.44 | 2234 | 645 | 5.52 / 1272.07 | 6 | 24 |
14 | 13 | 1793.16 | 20 | 14.46 | 2036 | 589 | 6.10 / 1272.66 | 6 | 16 |
15 | 13 | 1592.68 | 20 | 14.51 | 1724 | 500 | 6.60 / 1273.16 | 6 | 49 |
16 | 13 | 1401.48 | 20 | 14.58 | 1445 | 421 | 7.03 / 1273.58 | 6 | 13 |
17 | 13 | 864.20 | 20 | 14.69 | 1056 | 310 | 7.34 / 1273.89 | 6 | 21 |
18 | 13 | 342.88 | 20 | 14.80 | 672 | 199 | 7.54 / 1274.09 | 6 | 54 |
19 | 13 | 64.40 | 20 | 14.87 | 382 | 114 | 7.65 / 1274.20 | 6 | 32 |
20 | 13 | 17.08 | 20 | 14.87 | 346 | 103 | 7.75 / 1274.30 | 6 | 35 |
21 | 8 | -6.16 | 320 | 14.81 | 300 | 1422 | 9.17 / 1275.73 | 6 | 69 |
Average= | 12.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 97 | 14.74 | 458 | 655 | 0.65 / 1258.35 | 6 | 57 |
2 | 2 | 196.72 | 27 | 14.92 | 587 | 236 | 0.89 / 1258.59 | 6 | 53 |
3 | 10 | 1060.36 | 9 | 14.75 | 1717 | 228 | 1.12 / 1258.82 | 6 | 55 |
4 | 10 | 1140.52 | 7 | 14.73 | 1768 | 182 | 1.30 / 1259.00 | 6 | 56 |
5 | 10 | 1205.08 | 6 | 14.72 | 1892 | 167 | 1.47 / 1259.17 | 6 | 55 |
6 | 10 | 1248.96 | 4 | 14.70 | 2010 | 118 | 1.59 / 1259.29 | 6 | 50 |
7 | 3 | 1326.72 | 8 | 14.70 | 2084 | 245 | 1.83 / 1259.53 | 6 | 62 |
8 | 7 | 2024.92 | 40 | 14.59 | 2875 | 1678 | 3.51 / 1261.21 | 62 | 48 |
9 | 13 | 2017.00 | 20 | 14.53 | 2906 | 844 | 4.35 / 1262.05 | 6 | 51 |
10 | 13 | 1948.20 | 20 | 14.47 | 2807 | 812 | 5.17 / 1262.86 | 6 | 54 |
11 | 13 | 1854.80 | 20 | 14.40 | 2698 | 777 | 5.94 / 1263.64 | 6 | 58 |
12 | 13 | 1233.08 | 20 | 14.53 | 1911 | 555 | 6.50 / 1264.20 | 6 | 67 |
13 | 13 | 705.96 | 20 | 14.68 | 1240 | 364 | 6.86 / 1264.56 | 6 | 72 |
14 | 13 | 257.04 | 20 | 14.82 | 660 | 196 | 7.06 / 1264.76 | 6 | 74 |
15 | 8 | -3.56 | 400 | 14.81 | 303 | 1795 | 8.85 / 1266.55 | 6 | 75 |
Average= | 12.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 57 | 14.79 | 404 | 341 | 0.34 / 1249.24 | 6 | 8 |
2 | 10 | 1108.20 | 8 | 14.86 | 1142 | 136 | 0.48 / 1249.38 | 6 | 33 |
3 | 10 | 1185.36 | 7 | 14.80 | 1324 | 137 | 0.61 / 1249.51 | 6 | 29 |
4 | 10 | 1251.64 | 6 | 14.87 | 697 | 62 | 0.68 / 1249.58 | 6 | 47 |
5 | 10 | 1306.92 | 5 | 14.65 | 1974 | 145 | 0.82 / 1249.72 | 6 | 43 |
6 | 10 | 1347.56 | 4 | 14.67 | 2076 | 122 | 0.94 / 1249.84 | 6 | 36 |
7 | 3 | 1436.48 | 11 | 14.72 | 1898 | 307 | 1.25 / 1250.15 | 6 | 17 |
8 | 7 | 2020.28 | 40 | 14.72 | 2343 | 1380 | 2.63 / 1251.53 | 17 | 32 |
9 | 13 | 2069.24 | 20 | 14.70 | 2303 | 677 | 3.31 / 1252.21 | 5 | 50 |
10 | 13 | 2039.32 | 20 | 14.59 | 2364 | 690 | 4.00 / 1252.90 | 5 | 28 |
11 | 13 | 1972.56 | 20 | 14.58 | 2167 | 632 | 4.63 / 1253.53 | 6 | 27 |
12 | 13 | 1896.52 | 20 | 14.54 | 2004 | 583 | 5.21 / 1254.11 | 6 | 52 |
13 | 13 | 1812.20 | 20 | 14.47 | 2200 | 637 | 5.85 / 1254.75 | 6 | 34 |
14 | 13 | 1611.72 | 20 | 14.53 | 1702 | 495 | 6.34 / 1255.24 | 6 | 33 |
15 | 13 | 973.84 | 20 | 14.66 | 1226 | 359 | 6.70 / 1255.60 | 6 | 44 |
16 | 13 | 670.28 | 20 | 14.73 | 915 | 270 | 6.97 / 1255.87 | 6 | 46 |
17 | 13 | 139.36 | 20 | 14.86 | 447 | 133 | 7.10 / 1256.00 | 6 | 37 |
18 | 13 | 35.04 | 20 | 14.87 | 355 | 106 | 7.21 / 1256.11 | 6 | 14 |
19 | 8 | -5.56 | 360 | 14.81 | 298 | 1589 | 8.80 / 1257.70 | 6 | 65 |
Average= | 12.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 57 | 14.78 | 456 | 384 | 0.38 / 1241.75 | 6 | 54 |
2 | 7 | 2016.60 | 40 | 14.58 | 2877 | 1678 | 2.06 / 1243.43 | 54 | 50 |
3 | 13 | 2010.68 | 20 | 14.54 | 2877 | 837 | 2.90 / 1244.27 | 6 | 51 |
4 | 13 | 1940.44 | 20 | 14.46 | 2814 | 814 | 3.71 / 1245.08 | 6 | 55 |
5 | 13 | 1847.76 | 20 | 14.41 | 2688 | 775 | 4.49 / 1245.86 | 6 | 57 |
6 | 13 | 1442.20 | 20 | 14.46 | 2182 | 631 | 5.12 / 1246.49 | 6 | 65 |
7 | 13 | 764.72 | 20 | 14.65 | 1324 | 388 | 5.51 / 1246.87 | 6 | 72 |
8 | 13 | 316.68 | 20 | 14.78 | 759 | 224 | 5.73 / 1247.10 | 6 | 78 |
9 | 8 | -4.12 | 400 | 14.81 | 304 | 1801 | 7.53 / 1248.90 | 6 | 104 |
Average= | 13.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 105 | 14.75 | 456 | 706 | 0.71 / 1233.39 | 6 | 55 |
2 | 2 | 190.84 | 27 | 14.86 | 587 | 236 | 0.94 / 1233.62 | 6 | 50 |
3 | 10 | 1033.64 | 9 | 14.75 | 1649 | 219 | 1.16 / 1233.84 | 6 | 53 |
4 | 10 | 1111.48 | 7 | 14.72 | 1782 | 184 | 1.34 / 1234.03 | 6 | 55 |
5 | 10 | 1168.04 | 5 | 14.71 | 1860 | 137 | 1.48 / 1234.16 | 6 | 53 |
6 | 10 | 1210.20 | 4 | 14.71 | 1928 | 113 | 1.59 / 1234.28 | 6 | 48 |
7 | 3 | 1334.52 | 8 | 14.71 | 2006 | 236 | 1.83 / 1234.51 | 6 | 62 |
8 | 7 | 2009.48 | 40 | 14.59 | 2840 | 1657 | 3.49 / 1236.17 | 62 | 49 |
9 | 13 | 2011.80 | 20 | 14.54 | 2895 | 842 | 4.33 / 1237.01 | 6 | 52 |
10 | 13 | 1951.60 | 20 | 14.46 | 2796 | 809 | 5.14 / 1237.82 | 6 | 54 |
11 | 13 | 1860.08 | 20 | 14.40 | 2719 | 783 | 5.92 / 1238.60 | 6 | 57 |
12 | 13 | 1336.92 | 20 | 14.50 | 2029 | 588 | 6.51 / 1239.19 | 6 | 65 |
13 | 13 | 699.36 | 20 | 14.68 | 1231 | 361 | 6.87 / 1239.55 | 6 | 73 |
14 | 13 | 77.76 | 20 | 14.87 | 429 | 128 | 7.00 / 1239.68 | 6 | 67 |
15 | 8 | -5.56 | 376 | 14.82 | 303 | 1688 | 8.69 / 1241.37 | 6 | 135 |
Average= | 13.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 71 | 14.78 | 373 | 391 | 0.39 / 1224.42 | 6 | 6 |
2 | 10 | 1064.84 | 8 | 14.89 | 1120 | 133 | 0.52 / 1224.55 | 6 | 30 |
3 | 10 | 1142.44 | 7 | 14.91 | 1216 | 127 | 0.65 / 1224.68 | 6 | 34 |
4 | 10 | 1204.64 | 6 | 14.73 | 1461 | 129 | 0.78 / 1224.80 | 6 | 28 |
5 | 10 | 1248.04 | 4 | 14.72 | 1535 | 90 | 0.87 / 1224.89 | 6 | 19 |
6 | 3 | 1379.88 | 9 | 14.90 | 1258 | 169 | 1.04 / 1225.06 | 6 | 32 |
7 | 7 | 2017.60 | 40 | 14.73 | 2330 | 1373 | 2.41 / 1226.44 | 32 | 39 |
8 | 13 | 2059.96 | 20 | 14.79 | 1917 | 567 | 2.98 / 1227.00 | 5 | 32 |
9 | 13 | 2052.56 | 20 | 14.59 | 2403 | 701 | 3.68 / 1227.70 | 5 | 25 |
10 | 13 | 1998.72 | 20 | 14.54 | 2309 | 671 | 4.35 / 1228.38 | 6 | 29 |
11 | 13 | 1921.04 | 20 | 14.56 | 2082 | 606 | 4.96 / 1228.98 | 6 | 57 |
12 | 13 | 1827.04 | 20 | 14.48 | 2168 | 628 | 5.59 / 1229.61 | 6 | 33 |
13 | 13 | 1415.28 | 20 | 14.60 | 1478 | 432 | 6.02 / 1230.04 | 6 | 61 |
14 | 13 | 1114.84 | 20 | 14.65 | 1308 | 383 | 6.40 / 1230.43 | 6 | 22 |
15 | 13 | 805.44 | 20 | 14.71 | 981 | 289 | 6.69 / 1230.71 | 6 | 18 |
16 | 13 | 495.60 | 20 | 14.75 | 784 | 231 | 6.92 / 1230.95 | 6 | 36 |
17 | 13 | 89.16 | 20 | 14.86 | 399 | 119 | 7.04 / 1231.06 | 6 | 11 |
18 | 13 | 21.72 | 20 | 14.86 | 347 | 103 | 7.14 / 1231.17 | 6 | 34 |
19 | 8 | -6.64 | 340 | 14.80 | 301 | 1515 | 8.66 / 1232.68 | 6 | 76 |
Average= | 13.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 71 | 14.78 | 404 | 424 | 0.42 / 1216.95 | 6 | 32 |
2 | 3 | 1031.76 | 1 | 14.94 | 1654 | 25 | 0.45 / 1216.97 | 6 | 7 |
3 | 7 | 2010.96 | 41 | 14.59 | 2850 | 1705 | 2.15 / 1218.68 | 7 | 49 |
4 | 13 | 1999.44 | 20 | 14.54 | 2866 | 833 | 2.99 / 1219.51 | 5 | 52 |
5 | 13 | 1926.28 | 20 | 14.47 | 2746 | 795 | 3.78 / 1220.31 | 6 | 55 |
6 | 13 | 1733.92 | 20 | 14.45 | 2499 | 722 | 4.50 / 1221.03 | 6 | 57 |
7 | 13 | 1430.64 | 20 | 14.47 | 2118 | 613 | 5.12 / 1221.64 | 6 | 62 |
8 | 13 | 572.40 | 20 | 14.73 | 1011 | 298 | 5.41 / 1221.94 | 6 | 69 |
9 | 13 | 256.20 | 20 | 14.81 | 646 | 191 | 5.61 / 1222.13 | 6 | 69 |
10 | 13 | 38.12 | 20 | 14.88 | 374 | 111 | 5.72 / 1222.24 | 6 | 65 |
11 | 8 | -6.44 | 400 | 14.80 | 301 | 1782 | 7.50 / 1224.02 | 6 | 112 |
Average= | 13.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 59 | 14.78 | 421 | 367 | 0.37 / 1209.37 | 6 | 30 |
2 | 10 | 1060.40 | 6 | 14.73 | 1715 | 152 | 0.52 / 1209.52 | 6 | 56 |
3 | 10 | 1103.04 | 4 | 14.74 | 1768 | 104 | 0.62 / 1209.62 | 6 | 47 |
4 | 3 | 1140.00 | 3 | 14.82 | 1837 | 82 | 0.70 / 1209.70 | 6 | 47 |
5 | 7 | 2026.96 | 40 | 14.60 | 2824 | 1649 | 2.35 / 1211.35 | 47 | 50 |
6 | 13 | 2028.48 | 20 | 14.54 | 2823 | 821 | 3.17 / 1212.17 | 6 | 51 |
7 | 13 | 1965.52 | 20 | 14.47 | 2789 | 807 | 3.98 / 1212.98 | 6 | 55 |
8 | 13 | 1871.44 | 20 | 14.42 | 2651 | 765 | 4.75 / 1213.75 | 6 | 55 |
9 | 13 | 1340.12 | 20 | 14.51 | 1978 | 574 | 5.32 / 1214.32 | 6 | 63 |
10 | 13 | 592.92 | 20 | 14.72 | 1044 | 307 | 5.63 / 1214.63 | 6 | 68 |
11 | 13 | 52.60 | 20 | 14.88 | 384 | 114 | 5.74 / 1214.74 | 6 | 61 |
12 | 8 | -4.80 | 400 | 14.81 | 301 | 1783 | 7.53 / 1216.52 | 6 | 116 |
Average= | 13.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 57 | 14.78 | 467 | 393 | 0.39 / 1201.95 | 6 | 51 |
2 | 10 | 1003.00 | 3 | 14.81 | 1673 | 74 | 0.47 / 1202.02 | 6 | 40 |
3 | 7 | 2016.68 | 40 | 14.59 | 2860 | 1669 | 2.14 / 1203.69 | 40 | 47 |
4 | 13 | 2007.92 | 20 | 14.55 | 2856 | 831 | 2.97 / 1204.52 | 6 | 53 |
5 | 13 | 1934.32 | 20 | 14.47 | 2792 | 808 | 3.78 / 1205.33 | 6 | 57 |
6 | 13 | 1737.24 | 20 | 14.44 | 2536 | 732 | 4.51 / 1206.06 | 6 | 59 |
7 | 13 | 1437.28 | 20 | 14.47 | 2168 | 627 | 5.14 / 1206.69 | 6 | 64 |
8 | 13 | 670.00 | 20 | 14.68 | 1187 | 349 | 5.48 / 1207.04 | 6 | 70 |
9 | 13 | 134.24 | 20 | 14.85 | 491 | 146 | 5.63 / 1207.19 | 6 | 69 |
10 | 8 | -6.28 | 400 | 14.81 | 306 | 1813 | 7.44 / 1209.00 | 6 | 90 |
Average= | 13.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 117 | 14.75 | 462 | 797 | 0.80 / 1193.57 | 6 | 52 |
2 | 2 | 191.44 | 27 | 14.87 | 598 | 240 | 1.04 / 1193.81 | 6 | 44 |
3 | 10 | 1007.28 | 8 | 14.78 | 1618 | 191 | 1.23 / 1194.00 | 6 | 53 |
4 | 10 | 1092.08 | 8 | 14.74 | 1713 | 202 | 1.43 / 1194.20 | 6 | 54 |
5 | 10 | 1168.68 | 7 | 14.72 | 1806 | 186 | 1.62 / 1194.39 | 6 | 55 |
6 | 10 | 1219.40 | 5 | 14.71 | 1933 | 142 | 1.76 / 1194.53 | 6 | 50 |
7 | 3 | 1216.68 | 5 | 14.78 | 1885 | 139 | 1.90 / 1194.67 | 6 | 58 |
8 | 7 | 2022.96 | 41 | 14.59 | 2850 | 1705 | 3.60 / 1196.37 | 58 | 49 |
9 | 13 | 2012.16 | 20 | 14.54 | 2867 | 834 | 4.44 / 1197.21 | 6 | 52 |
10 | 13 | 1948.08 | 20 | 14.47 | 2787 | 807 | 5.24 / 1198.01 | 6 | 55 |
11 | 13 | 1851.80 | 20 | 14.41 | 2686 | 774 | 6.02 / 1198.79 | 6 | 57 |
12 | 13 | 1215.68 | 20 | 14.53 | 1866 | 542 | 6.56 / 1199.33 | 6 | 67 |
13 | 13 | 508.12 | 20 | 14.74 | 973 | 287 | 6.85 / 1199.62 | 6 | 72 |
14 | 13 | 57.92 | 20 | 14.88 | 404 | 120 | 6.97 / 1199.74 | 6 | 63 |
15 | 8 | -6.56 | 400 | 14.81 | 307 | 1819 | 8.79 / 1201.56 | 6 | 98 |
Average= | 13.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 57 | 14.79 | 370 | 312 | 0.31 / 1184.32 | 6 | 6 |
2 | 10 | 1032.44 | 10 | 14.96 | 402 | 60 | 0.37 / 1184.38 | 6 | 10 |
3 | 10 | 1126.20 | 9 | 14.93 | 762 | 102 | 0.47 / 1184.49 | 6 | 22 |
4 | 10 | 1209.12 | 8 | 14.93 | 515 | 62 | 0.54 / 1184.55 | 6 | 10 |
5 | 10 | 1289.28 | 7 | 14.98 | 454 | 48 | 0.58 / 1184.59 | 6 | 8 |
6 | 10 | 1361.48 | 7 | 14.91 | 780 | 81 | 0.66 / 1184.68 | 6 | 24 |
7 | 10 | 1420.96 | 5 | 14.92 | 570 | 43 | 0.71 / 1184.72 | 6 | 28 |
8 | 10 | 1467.80 | 4 | 14.61 | 2246 | 131 | 0.84 / 1184.85 | 6 | 30 |
9 | 10 | 1496.76 | 3 | 14.61 | 2308 | 101 | 0.94 / 1184.95 | 6 | 25 |
10 | 3 | 1474.88 | 12 | 15.05 | 414 | 75 | 1.01 / 1185.03 | 6 | 6 |
11 | 5 | 1345.28 | 8 | 14.96 | 1070 | 128 | 1.14 / 1185.15 | 6 | 53 |
12 | 7 | 2009.12 | 40 | 14.84 | 1997 | 1185 | 2.33 / 1186.34 | 53 | 23 |
13 | 13 | 2077.52 | 20 | 14.78 | 2160 | 638 | 2.97 / 1186.98 | 6 | 30 |
14 | 13 | 2095.80 | 20 | 14.73 | 1933 | 569 | 3.54 / 1187.55 | 6 | 17 |
15 | 13 | 2045.48 | 20 | 14.57 | 2336 | 681 | 4.22 / 1188.23 | 6 | 39 |
16 | 13 | 1972.36 | 20 | 14.54 | 2181 | 634 | 4.85 / 1188.86 | 6 | 26 |
17 | 13 | 1888.92 | 20 | 14.51 | 2054 | 596 | 5.45 / 1189.46 | 6 | 33 |
18 | 13 | 1796.00 | 20 | 14.47 | 1988 | 575 | 6.02 / 1190.03 | 6 | 30 |
19 | 13 | 1285.40 | 20 | 14.58 | 1546 | 451 | 6.47 / 1190.48 | 6 | 33 |
20 | 13 | 859.12 | 20 | 14.73 | 883 | 260 | 6.73 / 1190.74 | 6 | 6 |
21 | 13 | 675.88 | 20 | 14.73 | 916 | 270 | 7.00 / 1191.01 | 6 | 40 |
22 | 13 | 181.72 | 20 | 14.85 | 440 | 131 | 7.13 / 1191.14 | 6 | 10 |
23 | 13 | 55.52 | 20 | 14.87 | 364 | 108 | 7.24 / 1191.25 | 6 | 33 |
24 | 13 | 14.84 | 20 | 14.87 | 339 | 101 | 7.34 / 1191.35 | 6 | 30 |
25 | 8 | -6.36 | 320 | 14.81 | 299 | 1417 | 8.76 / 1192.77 | 6 | 89 |
Average= | 13.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 107 | 14.75 | 447 | 705 | 0.71 / 1175.76 | 6 | 53 |
2 | 2 | 183.00 | 27 | 14.87 | 572 | 230 | 0.94 / 1175.99 | 6 | 44 |
3 | 10 | 1014.20 | 9 | 14.75 | 1665 | 221 | 1.16 / 1176.21 | 6 | 56 |
4 | 10 | 1092.88 | 7 | 14.74 | 1733 | 179 | 1.33 / 1176.39 | 6 | 54 |
5 | 10 | 1158.56 | 6 | 14.72 | 1844 | 163 | 1.50 / 1176.56 | 6 | 54 |
6 | 10 | 1208.92 | 5 | 14.71 | 1932 | 142 | 1.64 / 1176.70 | 6 | 52 |
7 | 3 | 1292.80 | 7 | 14.73 | 1961 | 202 | 1.84 / 1176.90 | 6 | 62 |
8 | 7 | 2006.64 | 40 | 14.60 | 2834 | 1655 | 3.50 / 1178.56 | 62 | 49 |
9 | 13 | 1998.96 | 20 | 14.54 | 2859 | 831 | 4.33 / 1179.39 | 6 | 52 |
10 | 13 | 1938.80 | 20 | 14.48 | 2783 | 806 | 5.13 / 1180.19 | 6 | 55 |
11 | 13 | 1850.20 | 20 | 14.42 | 2665 | 769 | 5.90 / 1180.96 | 6 | 58 |
12 | 13 | 1316.72 | 20 | 14.50 | 2012 | 583 | 6.49 / 1181.54 | 6 | 67 |
13 | 13 | 699.08 | 20 | 14.67 | 1223 | 359 | 6.85 / 1181.90 | 6 | 71 |
14 | 13 | 378.52 | 20 | 14.80 | 677 | 200 | 7.05 / 1182.10 | 6 | 45 |
15 | 13 | 31.60 | 20 | 14.88 | 360 | 107 | 7.15 / 1182.21 | 6 | 73 |
16 | 8 | -6.76 | 400 | 14.80 | 304 | 1800 | 8.95 / 1184.01 | 6 | 74 |
Average= | 13.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 56 | 14.80 | 354 | 293 | 0.29 / 1166.31 | 6 | 6 |
2 | 10 | 1000.96 | 9 | 14.89 | 803 | 108 | 0.40 / 1166.42 | 6 | 7 |
3 | 10 | 1088.88 | 8 | 14.86 | 1136 | 135 | 0.54 / 1166.56 | 6 | 26 |
4 | 10 | 1169.64 | 7 | 14.96 | 418 | 44 | 0.58 / 1166.60 | 6 | 9 |
5 | 10 | 1238.64 | 6 | 14.70 | 1505 | 133 | 0.71 / 1166.73 | 6 | 24 |
6 | 10 | 1295.24 | 5 | 14.73 | 1282 | 94 | 0.81 / 1166.83 | 6 | 43 |
7 | 10 | 1334.84 | 4 | 14.64 | 2072 | 121 | 0.93 / 1166.95 | 6 | 38 |
8 | 10 | 1442.84 | 3 | 14.65 | 2262 | 99 | 1.03 / 1167.05 | 6 | 26 |
9 | 3 | 1451.56 | 11 | 15.05 | 430 | 71 | 1.10 / 1167.12 | 6 | 7 |
10 | 5 | 1300.64 | 7 | 15.31 | 417 | 45 | 1.14 / 1167.16 | 6 | 35 |
11 | 7 | 2006.36 | 40 | 14.88 | 1869 | 1112 | 2.26 / 1168.28 | 35 | 9 |
12 | 13 | 2071.04 | 20 | 14.68 | 2442 | 717 | 2.97 / 1168.99 | 5 | 18 |
13 | 13 | 2097.32 | 20 | 14.66 | 2248 | 659 | 3.63 / 1169.65 | 6 | 24 |
14 | 13 | 2051.76 | 20 | 14.70 | 1896 | 557 | 4.19 / 1170.21 | 6 | 18 |
15 | 13 | 1989.80 | 20 | 14.53 | 2260 | 657 | 4.85 / 1170.87 | 6 | 28 |
16 | 13 | 1915.64 | 20 | 14.45 | 2282 | 659 | 5.51 / 1171.53 | 6 | 28 |
17 | 13 | 1829.60 | 20 | 14.50 | 1903 | 552 | 6.06 / 1172.08 | 6 | 35 |
18 | 13 | 1537.60 | 20 | 14.55 | 1583 | 461 | 6.52 / 1172.54 | 6 | 23 |
19 | 13 | 1232.96 | 20 | 14.65 | 1158 | 339 | 6.86 / 1172.88 | 6 | 17 |
20 | 13 | 826.68 | 20 | 14.70 | 1033 | 304 | 7.16 / 1173.18 | 6 | 40 |
21 | 13 | 418.44 | 20 | 14.80 | 648 | 192 | 7.35 / 1173.37 | 6 | 26 |
22 | 13 | 230.80 | 20 | 14.82 | 520 | 154 | 7.51 / 1173.53 | 6 | 19 |
23 | 13 | 62.60 | 20 | 14.86 | 387 | 115 | 7.62 / 1173.64 | 6 | 34 |
24 | 8 | -6.60 | 320 | 14.80 | 299 | 1416 | 9.04 / 1175.06 | 6 | 91 |
Average= | 13.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 116 | 14.75 | 451 | 772 | 0.77 / 1157.67 | 6 | 48 |
2 | 2 | 190.88 | 27 | 14.88 | 577 | 232 | 1.00 / 1157.91 | 6 | 40 |
3 | 10 | 1029.72 | 9 | 14.76 | 1678 | 223 | 1.23 / 1158.13 | 6 | 54 |
4 | 10 | 1105.04 | 7 | 14.74 | 1771 | 183 | 1.41 / 1158.31 | 6 | 54 |
5 | 10 | 1162.84 | 5 | 14.72 | 1859 | 137 | 1.55 / 1158.45 | 6 | 53 |
6 | 10 | 1205.04 | 4 | 14.72 | 1935 | 114 | 1.66 / 1158.56 | 6 | 48 |
7 | 3 | 1294.96 | 7 | 14.75 | 1964 | 203 | 1.86 / 1158.76 | 6 | 61 |
8 | 7 | 2008.20 | 40 | 14.61 | 2816 | 1646 | 3.51 / 1160.41 | 61 | 50 |
9 | 13 | 1999.04 | 20 | 14.56 | 2854 | 831 | 4.34 / 1161.24 | 6 | 51 |
10 | 13 | 1926.92 | 20 | 14.48 | 2781 | 805 | 5.14 / 1162.05 | 6 | 55 |
11 | 13 | 1845.52 | 20 | 14.43 | 2656 | 767 | 5.91 / 1162.81 | 6 | 56 |
12 | 13 | 1756.84 | 20 | 14.38 | 2565 | 738 | 6.65 / 1163.55 | 6 | 60 |
13 | 13 | 803.96 | 20 | 14.64 | 1349 | 395 | 7.04 / 1163.95 | 6 | 71 |
14 | 13 | 176.52 | 20 | 14.83 | 548 | 163 | 7.21 / 1164.11 | 6 | 71 |
15 | 13 | 35.44 | 20 | 14.87 | 377 | 112 | 7.32 / 1164.22 | 6 | 67 |
16 | 8 | -6.88 | 400 | 14.80 | 304 | 1800 | 9.12 / 1166.02 | 6 | 86 |
Average= | 13.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 56 | 14.80 | 341 | 283 | 0.28 / 1147.46 | 6 | 6 |
2 | 10 | 1101.24 | 10 | 14.97 | 420 | 63 | 0.35 / 1147.52 | 6 | 8 |
3 | 10 | 1204.44 | 10 | 14.77 | 1194 | 176 | 0.52 / 1147.70 | 6 | 6 |
4 | 10 | 1300.60 | 9 | 14.84 | 1166 | 156 | 0.68 / 1147.86 | 6 | 39 |
5 | 10 | 1385.56 | 8 | 14.81 | 938 | 111 | 0.79 / 1147.97 | 6 | 8 |
6 | 10 | 1460.24 | 7 | 14.94 | 516 | 54 | 0.84 / 1148.02 | 6 | 58 |
7 | 10 | 1525.92 | 6 | 14.92 | 533 | 48 | 0.89 / 1148.07 | 6 | 73 |
8 | 10 | 1584.68 | 5 | 14.86 | 752 | 56 | 0.95 / 1148.13 | 6 | 54 |
9 | 10 | 1636.48 | 5 | 14.88 | 862 | 64 | 1.01 / 1148.19 | 6 | 36 |
10 | 10 | 1664.76 | 3 | 14.56 | 2545 | 111 | 1.12 / 1148.30 | 6 | 20 |
11 | 3 | 1614.52 | 15 | 14.93 | 1185 | 265 | 1.39 / 1148.57 | 6 | 23 |
12 | 5 | 1415.92 | 10 | 15.04 | 560 | 84 | 1.47 / 1148.65 | 6 | 29 |
13 | 7 | 2008.60 | 40 | 14.84 | 2025 | 1202 | 2.67 / 1149.85 | 29 | 12 |
14 | 13 | 2085.68 | 20 | 14.95 | 1355 | 405 | 3.08 / 1150.26 | 6 | 6 |
15 | 13 | 2142.52 | 20 | 14.83 | 1671 | 496 | 3.57 / 1150.75 | 6 | 12 |
16 | 13 | 2158.20 | 20 | 14.65 | 2253 | 660 | 4.23 / 1151.41 | 6 | 50 |
17 | 13 | 2108.48 | 20 | 14.60 | 2083 | 608 | 4.84 / 1152.02 | 6 | 14 |
18 | 13 | 2037.44 | 20 | 14.56 | 1887 | 549 | 5.39 / 1152.57 | 6 | 26 |
19 | 13 | 1955.52 | 20 | 14.59 | 1737 | 507 | 5.90 / 1153.08 | 6 | 19 |
20 | 13 | 1862.40 | 20 | 14.56 | 1546 | 450 | 6.35 / 1153.53 | 6 | 7 |
21 | 13 | 1766.68 | 20 | 14.56 | 1525 | 444 | 6.79 / 1153.97 | 6 | 48 |
22 | 13 | 1671.44 | 20 | 14.43 | 1935 | 558 | 7.35 / 1154.53 | 6 | 33 |
23 | 13 | 1047.48 | 20 | 14.65 | 1132 | 332 | 7.68 / 1154.86 | 6 | 13 |
24 | 13 | 845.76 | 20 | 14.70 | 904 | 266 | 7.95 / 1155.13 | 6 | 15 |
25 | 13 | 649.64 | 20 | 14.70 | 907 | 267 | 8.22 / 1155.39 | 6 | 36 |
26 | 13 | 319.44 | 20 | 14.79 | 553 | 164 | 8.38 / 1155.56 | 6 | 13 |
27 | 13 | 32.00 | 20 | 14.85 | 352 | 105 | 8.48 / 1155.66 | 6 | 32 |
28 | 8 | -6.52 | 280 | 14.80 | 299 | 1239 | 9.72 / 1156.90 | 6 | 95 |
Average= | 13.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 97 | 14.75 | 447 | 640 | 0.64 / 1139.03 | 6 | 48 |
2 | 2 | 186.68 | 27 | 14.91 | 578 | 233 | 0.87 / 1139.27 | 6 | 46 |
3 | 10 | 1031.40 | 9 | 14.78 | 1650 | 219 | 1.09 / 1139.48 | 6 | 54 |
4 | 10 | 1112.48 | 7 | 14.75 | 1742 | 180 | 1.27 / 1139.66 | 6 | 54 |
5 | 10 | 1175.76 | 6 | 14.72 | 1872 | 165 | 1.44 / 1139.83 | 6 | 54 |
6 | 10 | 1220.36 | 4 | 14.72 | 1946 | 115 | 1.55 / 1139.94 | 6 | 51 |
7 | 3 | 1276.00 | 7 | 14.73 | 2002 | 206 | 1.76 / 1140.15 | 6 | 62 |
8 | 7 | 2023.04 | 40 | 14.61 | 2849 | 1665 | 3.42 / 1141.82 | 62 | 49 |
9 | 13 | 2015.92 | 20 | 14.55 | 2891 | 841 | 4.26 / 1142.66 | 5 | 52 |
10 | 13 | 1948.04 | 20 | 14.48 | 2811 | 814 | 5.08 / 1143.47 | 6 | 54 |
11 | 13 | 1853.32 | 20 | 14.42 | 2682 | 773 | 5.85 / 1144.24 | 6 | 55 |
12 | 13 | 1214.08 | 20 | 14.53 | 1888 | 549 | 6.40 / 1144.79 | 6 | 66 |
13 | 13 | 693.52 | 20 | 14.67 | 1220 | 358 | 6.76 / 1145.15 | 6 | 70 |
14 | 13 | 141.48 | 20 | 14.84 | 511 | 152 | 6.91 / 1145.30 | 6 | 70 |
15 | 13 | 17.92 | 20 | 14.88 | 355 | 106 | 7.02 / 1145.41 | 6 | 73 |
16 | 8 | -6.56 | 400 | 14.80 | 299 | 1770 | 8.79 / 1147.18 | 6 | 91 |
Average= | 13.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.28 | 67 | 14.78 | 386 | 382 | 0.38 / 1130.04 | 6 | 9 |
2 | 10 | 1049.92 | 8 | 14.76 | 1282 | 151 | 0.53 / 1130.20 | 6 | 24 |
3 | 10 | 1124.00 | 7 | 14.91 | 723 | 75 | 0.61 / 1130.27 | 6 | 36 |
4 | 10 | 1180.68 | 5 | 14.70 | 1716 | 126 | 0.74 / 1130.40 | 6 | 46 |
5 | 10 | 1221.20 | 4 | 14.66 | 1918 | 112 | 0.85 / 1130.51 | 6 | 39 |
6 | 3 | 1327.28 | 8 | 14.96 | 1294 | 155 | 1.00 / 1130.66 | 6 | 37 |
7 | 7 | 2008.44 | 40 | 14.76 | 2359 | 1393 | 2.40 / 1132.06 | 37 | 16 |
8 | 13 | 2074.00 | 20 | 14.67 | 2370 | 695 | 3.09 / 1132.75 | 6 | 26 |
9 | 13 | 2065.72 | 20 | 14.61 | 2521 | 737 | 3.83 / 1133.49 | 6 | 14 |
10 | 13 | 2008.80 | 20 | 14.56 | 2304 | 671 | 4.50 / 1134.16 | 6 | 28 |
11 | 13 | 1928.56 | 20 | 14.59 | 2046 | 597 | 5.10 / 1134.76 | 6 | 45 |
12 | 13 | 1832.64 | 20 | 14.55 | 1994 | 580 | 5.68 / 1135.34 | 6 | 65 |
13 | 13 | 1627.12 | 20 | 14.57 | 1583 | 461 | 6.14 / 1135.80 | 6 | 45 |
14 | 13 | 1109.88 | 20 | 14.63 | 1302 | 381 | 6.52 / 1136.18 | 6 | 52 |
15 | 13 | 906.16 | 20 | 14.68 | 1030 | 302 | 6.82 / 1136.48 | 6 | 23 |
16 | 13 | 384.00 | 20 | 14.77 | 705 | 208 | 7.03 / 1136.69 | 6 | 35 |
17 | 13 | 26.24 | 20 | 14.87 | 352 | 105 | 7.13 / 1136.79 | 6 | 36 |
18 | 8 | -6.60 | 360 | 14.80 | 300 | 1598 | 8.73 / 1138.39 | 6 | 96 |
Average= | 13.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 53 | 14.78 | 407 | 319 | 0.32 / 1122.21 | 6 | 32 |
2 | 10 | 1084.24 | 6 | 14.73 | 1698 | 150 | 0.47 / 1122.36 | 6 | 54 |
3 | 10 | 1130.32 | 4 | 14.72 | 1818 | 107 | 0.58 / 1122.47 | 6 | 49 |
4 | 3 | 1211.88 | 5 | 14.77 | 1901 | 140 | 0.72 / 1122.61 | 6 | 56 |
5 | 7 | 2024.56 | 41 | 14.60 | 2819 | 1687 | 2.40 / 1124.30 | 56 | 50 |
6 | 13 | 2013.04 | 20 | 14.55 | 2854 | 831 | 3.23 / 1125.13 | 6 | 51 |
7 | 13 | 1943.40 | 20 | 14.48 | 2769 | 802 | 4.04 / 1125.93 | 6 | 54 |
8 | 13 | 1753.00 | 20 | 14.45 | 2528 | 731 | 4.77 / 1126.66 | 6 | 56 |
9 | 13 | 1340.84 | 20 | 14.50 | 1990 | 577 | 5.34 / 1127.24 | 6 | 63 |
10 | 13 | 696.88 | 20 | 14.68 | 1145 | 336 | 5.68 / 1127.57 | 6 | 49 |
11 | 13 | 273.32 | 20 | 14.82 | 586 | 174 | 5.85 / 1127.75 | 6 | 44 |
12 | 13 | 17.92 | 20 | 14.88 | 349 | 104 | 5.96 / 1127.85 | 6 | 43 |
13 | 8 | -6.44 | 400 | 14.80 | 306 | 1812 | 7.77 / 1129.66 | 6 | 80 |
Average= | 13.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 70 | 14.79 | 468 | 485 | 0.48 / 1115.03 | 6 | 53 |
2 | 3 | 504.76 | -8 | 15.29 | 3 | 0 | 0.00 / 1115.03 | 6 | 53 |
3 | 7 | 2017.36 | 40 | 14.61 | 2875 | 1680 | 2.16 / 1116.71 | 53 | 49 |
4 | 13 | 2008.44 | 20 | 14.57 | 2872 | 837 | 3.00 / 1117.55 | 6 | 50 |
5 | 13 | 1938.48 | 20 | 14.49 | 2809 | 814 | 3.82 / 1118.36 | 6 | 54 |
6 | 13 | 1752.88 | 20 | 14.45 | 2571 | 743 | 4.56 / 1119.10 | 6 | 58 |
7 | 13 | 1327.88 | 20 | 14.48 | 2037 | 590 | 5.15 / 1119.69 | 6 | 66 |
8 | 13 | 674.48 | 20 | 14.66 | 1207 | 354 | 5.50 / 1120.05 | 6 | 74 |
9 | 13 | 30.40 | 20 | 14.87 | 379 | 113 | 5.62 / 1120.16 | 6 | 65 |
10 | 8 | -6.80 | 384 | 14.80 | 305 | 1733 | 7.35 / 1121.89 | 6 | 131 |
Average= | 13.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 89 | 14.74 | 441 | 579 | 0.58 / 1108.32 | 6 | 51 |
2 | 3 | 31.20 | -15 | 15.29 | 3 | 0 | 0.00 / 1108.32 | 6 | 51 |
3 | 5 | 1786.56 | 19 | 14.66 | 2509 | 699 | 1.28 / 1109.02 | 6 | 49 |
4 | 7 | 2021.04 | 40 | 14.51 | 2843 | 1650 | 2.93 / 1110.67 | 49 | 51 |
5 | 13 | 1925.88 | 20 | 14.48 | 2790 | 808 | 3.74 / 1111.48 | 6 | 56 |
6 | 13 | 1386.04 | 20 | 14.58 | 2095 | 611 | 4.35 / 1112.09 | 6 | 64 |
7 | 13 | 844.84 | 20 | 14.69 | 1417 | 416 | 4.76 / 1112.51 | 6 | 71 |
8 | 13 | 301.12 | 20 | 14.85 | 705 | 209 | 4.97 / 1112.71 | 6 | 74 |
9 | 8 | -5.52 | 400 | 14.85 | 308 | 1830 | 6.80 / 1114.54 | 6 | 115 |
Average= | 13.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 61 | 14.76 | 408 | 367 | 0.37 / 1099.70 | 6 | 11 |
2 | 10 | 1021.96 | 8 | 14.92 | 608 | 73 | 0.44 / 1099.77 | 6 | 25 |
3 | 10 | 1097.28 | 7 | 14.95 | 407 | 43 | 0.48 / 1099.82 | 6 | 22 |
4 | 10 | 1159.20 | 6 | 14.71 | 1628 | 144 | 0.63 / 1099.96 | 6 | 48 |
5 | 10 | 1203.12 | 4 | 14.67 | 1869 | 110 | 0.74 / 1100.07 | 6 | 43 |
6 | 3 | 1264.12 | 6 | 14.95 | 744 | 67 | 0.80 / 1100.14 | 6 | 46 |
7 | 7 | 2006.40 | 40 | 14.87 | 1966 | 1169 | 1.97 / 1101.31 | 46 | 17 |
8 | 13 | 2075.92 | 20 | 14.70 | 2356 | 693 | 2.66 / 1102.00 | 6 | 22 |
9 | 13 | 2106.44 | 20 | 14.69 | 2265 | 665 | 3.33 / 1102.66 | 6 | 22 |
10 | 13 | 2064.44 | 20 | 14.57 | 2340 | 682 | 4.01 / 1103.35 | 6 | 25 |
11 | 13 | 1995.68 | 20 | 14.56 | 2150 | 626 | 4.64 / 1103.97 | 6 | 25 |
12 | 13 | 1905.96 | 20 | 14.51 | 2083 | 604 | 5.24 / 1104.58 | 6 | 30 |
13 | 13 | 1501.32 | 20 | 14.56 | 1721 | 501 | 5.74 / 1105.08 | 6 | 33 |
14 | 13 | 1305.68 | 20 | 14.59 | 1389 | 405 | 6.15 / 1105.48 | 6 | 15 |
15 | 13 | 777.64 | 20 | 14.72 | 901 | 265 | 6.41 / 1105.75 | 6 | 26 |
16 | 13 | 582.92 | 20 | 14.74 | 799 | 236 | 6.65 / 1105.98 | 6 | 31 |
17 | 13 | 184.20 | 20 | 14.82 | 474 | 140 | 6.79 / 1106.12 | 6 | 13 |
18 | 8 | -6.60 | 360 | 14.79 | 304 | 1619 | 8.41 / 1107.74 | 6 | 66 |
Average= | 14.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.28 | 91 | 14.74 | 463 | 621 | 0.62 / 1092.25 | 6 | 48 |
2 | 3 | 94.32 | -14 | 15.27 | 3 | 0 | 0.00 / 1092.25 | 6 | 48 |
3 | 7 | 2021.72 | 40 | 14.61 | 2821 | 1649 | 2.27 / 1093.90 | 48 | 49 |
4 | 13 | 2020.88 | 20 | 14.56 | 2845 | 828 | 3.10 / 1094.73 | 6 | 54 |
5 | 13 | 1954.88 | 20 | 14.49 | 2781 | 806 | 3.90 / 1095.53 | 6 | 53 |
6 | 13 | 1868.08 | 20 | 14.43 | 2691 | 777 | 4.68 / 1096.31 | 6 | 57 |
7 | 13 | 1457.92 | 20 | 14.45 | 2194 | 634 | 5.31 / 1096.94 | 6 | 62 |
8 | 13 | 804.64 | 20 | 14.62 | 1356 | 396 | 5.71 / 1097.34 | 6 | 71 |
9 | 13 | 235.04 | 20 | 14.80 | 619 | 183 | 5.89 / 1097.52 | 6 | 71 |
10 | 8 | -6.68 | 400 | 14.79 | 306 | 1810 | 7.70 / 1099.33 | 6 | 83 |
Average= | 14.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 57 | 14.78 | 370 | 312 | 0.31 / 1083.46 | 6 | 7 |
2 | 10 | 1084.08 | 8 | 14.97 | 422 | 51 | 0.36 / 1083.51 | 6 | 8 |
3 | 10 | 1164.28 | 7 | 14.93 | 807 | 84 | 0.45 / 1083.59 | 6 | 45 |
4 | 10 | 1234.36 | 6 | 14.86 | 959 | 86 | 0.53 / 1083.68 | 6 | 41 |
5 | 10 | 1286.88 | 5 | 14.64 | 2008 | 147 | 0.68 / 1083.83 | 6 | 47 |
6 | 10 | 1314.60 | 3 | 14.66 | 2077 | 91 | 0.77 / 1083.92 | 6 | 29 |
7 | 3 | 1312.72 | 8 | 14.89 | 1116 | 133 | 0.90 / 1084.05 | 5 | 58 |
8 | 7 | 2027.12 | 41 | 14.82 | 2134 | 1297 | 2.20 / 1085.35 | 58 | 13 |
9 | 13 | 2087.44 | 20 | 14.71 | 2379 | 700 | 2.90 / 1086.05 | 6 | 32 |
10 | 13 | 2095.72 | 20 | 14.67 | 2230 | 654 | 3.55 / 1086.70 | 5 | 23 |
11 | 13 | 2036.68 | 20 | 14.60 | 2340 | 683 | 4.24 / 1087.39 | 6 | 69 |
12 | 13 | 1956.32 | 20 | 14.57 | 2142 | 624 | 4.86 / 1088.01 | 6 | 28 |
13 | 13 | 1863.16 | 20 | 14.48 | 2079 | 602 | 5.46 / 1088.61 | 6 | 29 |
14 | 13 | 1453.80 | 20 | 14.58 | 1632 | 476 | 5.94 / 1089.09 | 6 | 40 |
15 | 13 | 1041.64 | 20 | 14.67 | 1120 | 329 | 6.27 / 1089.42 | 6 | 47 |
16 | 13 | 845.32 | 20 | 14.67 | 1114 | 327 | 6.60 / 1089.74 | 6 | 31 |
17 | 13 | 320.28 | 20 | 14.80 | 617 | 183 | 6.78 / 1089.93 | 6 | 41 |
18 | 13 | 28.48 | 20 | 14.86 | 353 | 105 | 6.88 / 1090.03 | 6 | 38 |
19 | 8 | -6.76 | 359 | 14.79 | 301 | 1598 | 8.48 / 1091.63 | 6 | 77 |
Average= | 14.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 102 | 14.73 | 459 | 690 | 0.69 / 1074.98 | 6 | 49 |
2 | 2 | 190.20 | 27 | 14.85 | 589 | 236 | 0.93 / 1075.22 | 6 | 46 |
3 | 10 | 1060.20 | 9 | 14.73 | 1704 | 226 | 1.15 / 1075.45 | 6 | 54 |
4 | 10 | 1136.00 | 7 | 14.71 | 1822 | 188 | 1.34 / 1075.63 | 6 | 54 |
5 | 10 | 1193.80 | 5 | 14.69 | 1921 | 141 | 1.48 / 1075.77 | 6 | 54 |
6 | 10 | 1234.84 | 4 | 14.69 | 1949 | 115 | 1.59 / 1075.89 | 6 | 48 |
7 | 3 | 1338.44 | 8 | 14.73 | 2015 | 237 | 1.83 / 1076.13 | 5 | 62 |
8 | 7 | 2024.00 | 40 | 14.60 | 2890 | 1688 | 3.52 / 1077.81 | 62 | 49 |
9 | 13 | 2007.24 | 20 | 14.54 | 2886 | 839 | 4.36 / 1078.65 | 5 | 51 |
10 | 13 | 1935.88 | 20 | 14.48 | 2800 | 811 | 5.17 / 1079.46 | 6 | 55 |
11 | 13 | 1746.32 | 20 | 14.44 | 2562 | 740 | 5.91 / 1080.20 | 6 | 59 |
12 | 13 | 1435.84 | 20 | 14.45 | 2173 | 628 | 6.54 / 1080.83 | 6 | 64 |
13 | 13 | 641.20 | 20 | 14.67 | 1170 | 343 | 6.88 / 1081.18 | 6 | 73 |
14 | 13 | 201.00 | 20 | 14.81 | 588 | 174 | 7.06 / 1081.35 | 6 | 74 |
15 | 8 | -5.52 | 400 | 14.79 | 304 | 1798 | 8.85 / 1083.15 | 6 | 75 |
Average= | 14.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 58 | 14.78 | 341 | 292 | 0.29 / 1065.90 | 6 | 6 |
2 | 10 | 1013.36 | 10 | 14.79 | 1138 | 168 | 0.46 / 1066.06 | 6 | 20 |
3 | 10 | 1106.16 | 9 | 14.88 | 636 | 85 | 0.55 / 1066.15 | 6 | 16 |
4 | 10 | 1186.00 | 7 | 14.83 | 1263 | 131 | 0.68 / 1066.28 | 6 | 71 |
5 | 10 | 1249.08 | 6 | 14.81 | 768 | 68 | 0.75 / 1066.35 | 6 | 61 |
6 | 10 | 1297.28 | 4 | 14.63 | 1993 | 117 | 0.86 / 1066.47 | 6 | 43 |
7 | 10 | 1330.48 | 3 | 14.63 | 2050 | 90 | 0.95 / 1066.56 | 6 | 32 |
8 | 3 | 1357.96 | 9 | 14.99 | 604 | 81 | 1.03 / 1066.64 | 6 | 18 |
9 | 7 | 2012.28 | 40 | 14.86 | 1947 | 1157 | 2.19 / 1067.79 | 18 | 6 |
10 | 13 | 2075.72 | 20 | 14.81 | 2110 | 625 | 2.82 / 1068.42 | 5 | 41 |
11 | 13 | 2110.96 | 20 | 14.65 | 2335 | 684 | 3.50 / 1069.10 | 5 | 22 |
12 | 13 | 2069.80 | 20 | 14.50 | 2660 | 771 | 4.27 / 1069.88 | 6 | 45 |
13 | 13 | 2000.68 | 20 | 14.43 | 2603 | 751 | 5.02 / 1070.63 | 5 | 28 |
14 | 13 | 1910.08 | 20 | 14.40 | 2410 | 694 | 5.72 / 1071.32 | 6 | 53 |
15 | 13 | 1371.92 | 20 | 14.50 | 1883 | 546 | 6.26 / 1071.87 | 6 | 46 |
16 | 13 | 871.84 | 20 | 14.64 | 1230 | 360 | 6.62 / 1072.23 | 6 | 38 |
17 | 13 | 561.28 | 20 | 14.71 | 928 | 273 | 6.90 / 1072.50 | 6 | 45 |
18 | 13 | 65.20 | 20 | 14.86 | 383 | 114 | 7.01 / 1072.61 | 6 | 40 |
19 | 8 | -6.56 | 380 | 14.79 | 299 | 1680 | 8.69 / 1074.29 | 6 | 96 |
Average= | 14.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 85 | 14.73 | 455 | 570 | 0.57 / 1058.77 | 6 | 54 |
2 | 3 | 161.48 | -13 | 15.26 | 3 | 0 | 0.00 / 1058.77 | 6 | 54 |
3 | 7 | 2025.08 | 41 | 14.60 | 2847 | 1704 | 2.27 / 1060.47 | 54 | 49 |
4 | 13 | 2006.52 | 20 | 14.56 | 2876 | 837 | 3.11 / 1061.31 | 6 | 54 |
5 | 13 | 1932.20 | 20 | 14.48 | 2821 | 817 | 3.93 / 1062.13 | 6 | 54 |
6 | 13 | 1537.24 | 20 | 14.49 | 2274 | 659 | 4.59 / 1062.79 | 6 | 61 |
7 | 13 | 1332.88 | 20 | 14.48 | 2037 | 590 | 5.18 / 1063.38 | 6 | 64 |
8 | 13 | 567.40 | 20 | 14.69 | 1068 | 314 | 5.49 / 1063.69 | 6 | 76 |
9 | 13 | 36.32 | 20 | 14.86 | 374 | 111 | 5.60 / 1063.80 | 6 | 67 |
10 | 8 | -6.56 | 400 | 14.78 | 305 | 1803 | 7.41 / 1065.60 | 6 | 96 |
Average= | 14.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 62 | 14.75 | 396 | 362 | 0.36 / 1050.24 | 6 | 13 |
2 | 10 | 1015.28 | 8 | 14.91 | 866 | 103 | 0.47 / 1050.34 | 6 | 29 |
3 | 10 | 1087.08 | 7 | 14.78 | 1123 | 116 | 0.58 / 1050.46 | 6 | 51 |
4 | 10 | 1141.28 | 5 | 14.66 | 1831 | 134 | 0.72 / 1050.59 | 6 | 50 |
5 | 10 | 1172.76 | 3 | 14.69 | 1873 | 83 | 0.80 / 1050.67 | 6 | 38 |
6 | 3 | 1184.88 | 5 | 14.77 | 1885 | 139 | 0.94 / 1050.81 | 6 | 52 |
7 | 7 | 2024.12 | 40 | 14.72 | 2429 | 1430 | 2.37 / 1052.24 | 52 | 22 |
8 | 13 | 2066.40 | 20 | 14.71 | 2353 | 692 | 3.06 / 1052.94 | 5 | 22 |
9 | 13 | 2021.92 | 20 | 14.57 | 2617 | 763 | 3.82 / 1053.70 | 5 | 31 |
10 | 13 | 1945.20 | 20 | 14.46 | 2656 | 768 | 4.59 / 1054.47 | 6 | 32 |
11 | 13 | 1853.64 | 20 | 14.42 | 2445 | 705 | 5.30 / 1055.17 | 5 | 32 |
12 | 13 | 1143.52 | 20 | 14.61 | 1447 | 423 | 5.72 / 1055.60 | 6 | 13 |
13 | 13 | 947.12 | 20 | 14.65 | 1239 | 363 | 6.08 / 1055.96 | 6 | 20 |
14 | 13 | 747.40 | 20 | 14.66 | 1118 | 328 | 6.41 / 1056.29 | 6 | 39 |
15 | 13 | 45.80 | 20 | 14.86 | 384 | 114 | 6.52 / 1056.40 | 6 | 52 |
16 | 8 | -6.80 | 400 | 14.79 | 304 | 1798 | 8.32 / 1058.20 | 6 | 82 |
Average= | 14.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 62 | 14.73 | 465 | 425 | 0.42 / 1042.90 | 6 | 55 |
2 | 3 | 1021.88 | 1 | 14.90 | 1747 | 26 | 0.45 / 1042.92 | 6 | 6 |
3 | 7 | 2008.32 | 40 | 14.61 | 2837 | 1658 | 2.11 / 1044.58 | 6 | 49 |
4 | 13 | 2000.44 | 20 | 14.56 | 2856 | 832 | 2.94 / 1045.41 | 6 | 50 |
5 | 13 | 1935.40 | 20 | 14.48 | 2798 | 810 | 3.75 / 1046.22 | 6 | 54 |
6 | 13 | 1842.72 | 20 | 14.43 | 2679 | 773 | 4.52 / 1046.99 | 6 | 56 |
7 | 13 | 1193.12 | 20 | 14.54 | 1848 | 537 | 5.06 / 1047.53 | 6 | 65 |
8 | 13 | 785.36 | 20 | 14.63 | 1358 | 397 | 5.46 / 1047.93 | 6 | 76 |
9 | 13 | 66.84 | 20 | 14.86 | 421 | 125 | 5.58 / 1048.05 | 6 | 70 |
10 | 8 | -4.92 | 400 | 14.79 | 308 | 1822 | 7.41 / 1049.88 | 6 | 61 |
Average= | 14.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 85 | 14.72 | 455 | 569 | 0.57 / 1035.61 | 6 | 58 |
2 | 3 | 285.44 | -11 | 15.26 | 3 | 0 | 0.00 / 1035.61 | 6 | 58 |
3 | 7 | 2006.56 | 40 | 14.62 | 2830 | 1655 | 2.22 / 1037.26 | 58 | 48 |
4 | 13 | 1997.16 | 20 | 14.56 | 2865 | 834 | 3.06 / 1038.10 | 5 | 50 |
5 | 13 | 1924.48 | 20 | 14.48 | 2802 | 811 | 3.87 / 1038.91 | 6 | 55 |
6 | 13 | 1730.68 | 20 | 14.45 | 2555 | 738 | 4.61 / 1039.65 | 5 | 60 |
7 | 13 | 1407.36 | 20 | 14.47 | 2132 | 617 | 5.23 / 1040.26 | 6 | 64 |
8 | 13 | 652.84 | 20 | 14.66 | 1184 | 347 | 5.57 / 1040.61 | 6 | 77 |
9 | 13 | 109.76 | 20 | 14.84 | 469 | 139 | 5.71 / 1040.75 | 6 | 70 |
10 | 8 | -6.56 | 379 | 14.79 | 307 | 1721 | 7.43 / 1042.47 | 6 | 130 |
Average= | 14.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 60 | 14.75 | 414 | 366 | 0.37 / 1027.52 | 6 | 23 |
2 | 10 | 1039.88 | 8 | 14.83 | 866 | 103 | 0.47 / 1027.63 | 6 | 56 |
3 | 10 | 1101.36 | 6 | 14.67 | 1771 | 156 | 0.63 / 1027.78 | 6 | 54 |
4 | 10 | 1147.40 | 4 | 14.67 | 1847 | 108 | 0.73 / 1027.89 | 6 | 50 |
5 | 10 | 1183.12 | 3 | 14.65 | 1933 | 85 | 0.82 / 1027.98 | 6 | 43 |
6 | 3 | 1261.76 | 6 | 14.75 | 1907 | 169 | 0.99 / 1028.15 | 6 | 60 |
7 | 7 | 2022.24 | 40 | 14.69 | 2481 | 1458 | 2.44 / 1029.60 | 60 | 37 |
8 | 13 | 2050.76 | 20 | 14.56 | 2873 | 837 | 3.28 / 1030.44 | 5 | 50 |
9 | 13 | 1986.60 | 20 | 14.50 | 2836 | 822 | 4.10 / 1031.26 | 6 | 54 |
10 | 13 | 1894.20 | 20 | 14.44 | 2711 | 783 | 4.89 / 1032.04 | 6 | 56 |
11 | 13 | 1469.76 | 20 | 14.47 | 2168 | 627 | 5.51 / 1032.67 | 6 | 61 |
12 | 13 | 753.60 | 20 | 14.68 | 1203 | 353 | 5.87 / 1033.03 | 6 | 46 |
13 | 13 | 249.36 | 20 | 14.81 | 619 | 183 | 6.05 / 1033.21 | 6 | 61 |
14 | 8 | -3.36 | 400 | 14.80 | 309 | 1829 | 7.88 / 1035.04 | 6 | 115 |
Average= | 14.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 62 | 14.72 | 484 | 442 | 0.44 / 1020.09 | 6 | 63 |
2 | 3 | 967.20 | -1 | 15.24 | 3 | 0 | 0.00 / 1020.09 | 6 | 63 |
3 | 7 | 2023.84 | 40 | 14.60 | 2915 | 1702 | 2.14 / 1021.79 | 63 | 48 |
4 | 13 | 2007.36 | 20 | 14.55 | 2901 | 844 | 2.99 / 1022.63 | 6 | 53 |
5 | 13 | 1935.56 | 20 | 14.47 | 2859 | 827 | 3.82 / 1023.46 | 6 | 56 |
6 | 13 | 1749.84 | 20 | 14.43 | 2601 | 751 | 4.57 / 1024.21 | 6 | 62 |
7 | 13 | 1329.80 | 20 | 14.49 | 2044 | 592 | 5.16 / 1024.80 | 6 | 65 |
8 | 13 | 785.84 | 20 | 14.63 | 1357 | 397 | 5.56 / 1025.20 | 6 | 73 |
9 | 13 | 48.00 | 20 | 14.87 | 399 | 119 | 5.67 / 1025.32 | 6 | 68 |
10 | 8 | -6.48 | 400 | 14.79 | 311 | 1840 | 7.51 / 1027.16 | 6 | 85 |
Average= | 14.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 70 | 14.72 | 463 | 477 | 0.48 / 1012.76 | 6 | 62 |
2 | 3 | 720.00 | -4 | 15.24 | 3 | 0 | 0.00 / 1012.76 | 6 | 62 |
3 | 7 | 2008.08 | 41 | 14.59 | 2874 | 1719 | 2.20 / 1014.48 | 62 | 49 |
4 | 13 | 1995.68 | 20 | 14.56 | 2872 | 836 | 3.03 / 1015.31 | 6 | 54 |
5 | 13 | 1924.16 | 20 | 14.48 | 2795 | 809 | 3.84 / 1016.12 | 6 | 55 |
6 | 13 | 1731.40 | 20 | 14.44 | 2570 | 742 | 4.58 / 1016.87 | 6 | 61 |
7 | 13 | 1207.16 | 20 | 14.52 | 1889 | 549 | 5.13 / 1017.41 | 6 | 68 |
8 | 13 | 574.08 | 20 | 14.70 | 1092 | 321 | 5.45 / 1017.74 | 6 | 79 |
9 | 13 | 70.08 | 20 | 14.85 | 425 | 126 | 5.58 / 1017.86 | 6 | 70 |
10 | 8 | -6.60 | 389 | 14.78 | 310 | 1782 | 7.36 / 1019.64 | 6 | 131 |
Average= | 14.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 91 | 14.72 | 425 | 569 | 0.57 / 1005.42 | 6 | 54 |
2 | 3 | 383.48 | -10 | 15.25 | 3 | 0 | 0.00 / 1005.42 | 6 | 54 |
3 | 7 | 2008.20 | 40 | 14.63 | 2837 | 1660 | 2.23 / 1007.08 | 54 | 50 |
4 | 13 | 1993.16 | 20 | 14.58 | 2841 | 828 | 3.06 / 1007.90 | 6 | 53 |
5 | 13 | 1921.08 | 20 | 14.51 | 2753 | 799 | 3.86 / 1008.70 | 6 | 54 |
6 | 13 | 1826.04 | 20 | 14.45 | 2651 | 766 | 4.62 / 1009.47 | 6 | 57 |
7 | 13 | 1187.00 | 20 | 14.53 | 1843 | 536 | 5.16 / 1010.01 | 6 | 67 |
8 | 13 | 669.92 | 20 | 14.66 | 1184 | 347 | 5.51 / 1010.35 | 6 | 72 |
9 | 13 | 25.60 | 20 | 14.87 | 362 | 108 | 5.61 / 1010.46 | 6 | 62 |
10 | 8 | -3.76 | 400 | 14.78 | 308 | 1821 | 7.43 / 1012.28 | 6 | 120 |
Average= | 15.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 62 | 14.74 | 415 | 379 | 0.38 / 996.32 | 6 | 24 |
2 | 10 | 1081.12 | 8 | 14.82 | 1237 | 147 | 0.53 / 996.47 | 6 | 40 |
3 | 10 | 1147.00 | 6 | 14.69 | 1498 | 132 | 0.66 / 996.60 | 6 | 55 |
4 | 10 | 1201.60 | 5 | 14.66 | 1838 | 135 | 0.79 / 996.74 | 6 | 50 |
5 | 10 | 1246.28 | 4 | 14.66 | 1922 | 113 | 0.91 / 996.85 | 6 | 46 |
6 | 10 | 1277.92 | 3 | 14.65 | 2030 | 89 | 0.99 / 996.94 | 6 | 36 |
7 | 3 | 1277.84 | 7 | 15.01 | 577 | 61 | 1.06 / 997.00 | 6 | 52 |
8 | 7 | 2015.68 | 40 | 14.74 | 2427 | 1431 | 2.49 / 998.43 | 52 | 37 |
9 | 13 | 2076.88 | 20 | 14.67 | 2411 | 707 | 3.19 / 999.14 | 6 | 35 |
10 | 13 | 2063.32 | 20 | 14.67 | 2304 | 676 | 3.87 / 999.81 | 6 | 30 |
11 | 13 | 2009.32 | 20 | 14.53 | 2555 | 742 | 4.61 / 1000.56 | 6 | 31 |
12 | 13 | 1927.96 | 20 | 14.55 | 2111 | 614 | 5.23 / 1001.17 | 6 | 14 |
13 | 13 | 1833.64 | 20 | 14.46 | 2313 | 669 | 5.90 / 1001.84 | 6 | 36 |
14 | 13 | 1515.20 | 20 | 14.50 | 1756 | 509 | 6.40 / 1002.35 | 6 | 58 |
15 | 13 | 993.88 | 20 | 14.65 | 1184 | 347 | 6.75 / 1002.70 | 6 | 26 |
16 | 13 | 792.40 | 20 | 14.68 | 1021 | 300 | 7.05 / 1003.00 | 6 | 38 |
17 | 13 | 160.44 | 20 | 14.84 | 460 | 137 | 7.19 / 1003.13 | 6 | 14 |
18 | 8 | -6.56 | 380 | 14.79 | 305 | 1714 | 8.90 / 1004.85 | 6 | 68 |
Average= | 15.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 61 | 14.72 | 491 | 441 | 0.44 / 988.89 | 6 | 65 |
2 | 3 | 1021.40 | 1 | 14.91 | 1758 | 26 | 0.47 / 988.92 | 6 | 7 |
3 | 7 | 2005.64 | 40 | 14.60 | 2885 | 1685 | 2.15 / 990.60 | 7 | 55 |
4 | 13 | 1986.48 | 20 | 14.55 | 2876 | 837 | 2.99 / 991.44 | 6 | 53 |
5 | 13 | 1917.68 | 20 | 14.48 | 2816 | 816 | 3.80 / 992.26 | 6 | 58 |
6 | 13 | 1822.32 | 20 | 14.43 | 2680 | 773 | 4.58 / 993.03 | 6 | 60 |
7 | 13 | 1177.88 | 20 | 14.53 | 1859 | 540 | 5.12 / 993.57 | 6 | 69 |
8 | 13 | 736.84 | 20 | 14.64 | 1289 | 377 | 5.50 / 993.95 | 6 | 74 |
9 | 13 | 170.20 | 20 | 14.83 | 555 | 165 | 5.66 / 994.11 | 6 | 76 |
10 | 8 | -6.80 | 400 | 14.78 | 310 | 1833 | 7.49 / 995.95 | 6 | 100 |
Average= | 15.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 62 | 14.72 | 475 | 434 | 0.43 / 981.73 | 6 | 64 |
2 | 3 | 965.00 | -1 | 15.24 | 3 | 0 | 0.00 / 981.73 | 6 | 64 |
3 | 7 | 2015.12 | 40 | 14.60 | 2897 | 1692 | 2.13 / 983.42 | 64 | 53 |
4 | 13 | 2005.92 | 20 | 14.55 | 2925 | 851 | 2.98 / 984.27 | 6 | 52 |
5 | 13 | 1935.24 | 20 | 14.49 | 2797 | 811 | 3.79 / 985.08 | 6 | 54 |
6 | 13 | 1634.96 | 20 | 14.46 | 2440 | 706 | 4.49 / 985.79 | 6 | 61 |
7 | 13 | 1232.32 | 20 | 14.51 | 1942 | 564 | 5.06 / 986.35 | 6 | 67 |
8 | 13 | 464.16 | 20 | 14.73 | 952 | 280 | 5.34 / 986.63 | 6 | 81 |
9 | 13 | 35.76 | 20 | 14.87 | 387 | 115 | 5.45 / 986.75 | 6 | 66 |
10 | 8 | -2.92 | 366 | 14.79 | 315 | 1705 | 7.16 / 988.45 | 6 | 132 |
Average= | 15.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 86 | 14.71 | 455 | 576 | 0.58 / 974.51 | 6 | 63 |
2 | 3 | 311.32 | -11 | 15.25 | 3 | 0 | 0.00 / 974.51 | 6 | 63 |
3 | 7 | 2009.16 | 40 | 14.62 | 2875 | 1681 | 2.26 / 976.19 | 63 | 49 |
4 | 13 | 1988.60 | 20 | 14.57 | 2880 | 839 | 3.10 / 977.03 | 6 | 54 |
5 | 13 | 1904.04 | 20 | 14.51 | 2757 | 800 | 3.90 / 977.83 | 6 | 53 |
6 | 13 | 1608.24 | 20 | 14.48 | 2398 | 694 | 4.59 / 978.53 | 6 | 61 |
7 | 13 | 1196.28 | 20 | 14.52 | 1881 | 546 | 5.14 / 979.07 | 6 | 69 |
8 | 13 | 762.52 | 20 | 14.62 | 1321 | 386 | 5.52 / 979.46 | 6 | 74 |
9 | 8 | -3.00 | 398 | 14.78 | 312 | 1835 | 7.36 / 981.30 | 6 | 130 |
Average= | 15.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 62 | 14.74 | 419 | 383 | 0.38 / 966.30 | 6 | 31 |
2 | 10 | 1033.56 | 8 | 14.70 | 1566 | 184 | 0.57 / 966.48 | 6 | 60 |
3 | 10 | 1104.84 | 7 | 14.67 | 1754 | 180 | 0.75 / 966.66 | 6 | 56 |
4 | 10 | 1161.36 | 5 | 14.66 | 1802 | 132 | 0.88 / 966.79 | 6 | 53 |
5 | 10 | 1195.92 | 3 | 14.65 | 1908 | 84 | 0.96 / 966.88 | 6 | 40 |
6 | 3 | 1163.08 | 4 | 14.79 | 1807 | 107 | 1.07 / 966.99 | 6 | 50 |
7 | 7 | 2021.24 | 41 | 14.62 | 2835 | 1699 | 2.77 / 968.69 | 50 | 48 |
8 | 13 | 2002.16 | 20 | 14.58 | 2831 | 826 | 3.59 / 969.51 | 6 | 50 |
9 | 13 | 1930.96 | 20 | 14.52 | 2707 | 786 | 4.38 / 970.30 | 6 | 53 |
10 | 13 | 1739.08 | 20 | 14.47 | 2508 | 726 | 5.11 / 971.02 | 6 | 58 |
11 | 13 | 1421.80 | 20 | 14.49 | 2082 | 603 | 5.71 / 971.63 | 6 | 61 |
12 | 13 | 639.84 | 20 | 14.69 | 1083 | 318 | 6.03 / 971.94 | 6 | 45 |
13 | 13 | 222.48 | 20 | 14.82 | 576 | 171 | 6.20 / 972.11 | 6 | 45 |
14 | 8 | -4.24 | 400 | 14.79 | 308 | 1822 | 8.02 / 973.94 | 6 | 111 |
Average= | 15.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 62 | 14.72 | 479 | 437 | 0.44 / 958.99 | 6 | 63 |
2 | 7 | 2018.80 | 40 | 14.61 | 2868 | 1676 | 2.11 / 960.67 | 63 | 50 |
3 | 13 | 2002.76 | 20 | 14.55 | 2920 | 850 | 2.96 / 961.52 | 6 | 53 |
4 | 13 | 1932.76 | 20 | 14.48 | 2839 | 822 | 3.79 / 962.34 | 6 | 55 |
5 | 13 | 1737.04 | 20 | 14.45 | 2573 | 744 | 4.53 / 963.09 | 6 | 59 |
6 | 13 | 1094.72 | 20 | 14.55 | 1758 | 512 | 5.04 / 963.60 | 6 | 69 |
7 | 13 | 469.80 | 20 | 14.73 | 960 | 283 | 5.32 / 963.88 | 6 | 79 |
8 | 13 | 258.96 | 20 | 14.79 | 686 | 203 | 5.53 / 964.08 | 6 | 81 |
9 | 8 | -3.16 | 400 | 14.78 | 310 | 1833 | 7.36 / 965.92 | 6 | 82 |
Average= | 15.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 73 | 14.71 | 456 | 490 | 0.49 / 951.95 | 6 | 63 |
2 | 3 | 675.88 | -5 | 15.24 | 3 | 0 | 0.00 / 951.95 | 6 | 63 |
3 | 7 | 2008.88 | 40 | 14.60 | 2871 | 1677 | 2.17 / 953.62 | 63 | 50 |
4 | 13 | 1993.48 | 20 | 14.56 | 2869 | 835 | 3.00 / 954.46 | 6 | 53 |
5 | 13 | 1917.52 | 20 | 14.51 | 2764 | 802 | 3.80 / 955.26 | 6 | 54 |
6 | 13 | 1625.12 | 20 | 14.47 | 2408 | 697 | 4.50 / 955.96 | 6 | 59 |
7 | 13 | 1017.56 | 20 | 14.58 | 1649 | 481 | 4.98 / 956.44 | 6 | 70 |
8 | 13 | 504.56 | 20 | 14.72 | 1001 | 295 | 5.28 / 956.73 | 6 | 80 |
9 | 8 | -6.68 | 400 | 14.80 | 308 | 1823 | 7.10 / 958.56 | 6 | 124 |
Average= | 15.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 94 | 14.71 | 455 | 629 | 0.63 / 944.47 | 6 | 54 |
2 | 3 | 338.72 | -10 | 15.26 | 3 | 0 | 0.00 / 944.47 | 6 | 54 |
3 | 7 | 2020.28 | 40 | 14.63 | 2821 | 1651 | 2.28 / 946.12 | 54 | 48 |
4 | 13 | 2005.60 | 20 | 14.57 | 2861 | 834 | 3.11 / 946.96 | 6 | 51 |
5 | 13 | 1926.68 | 20 | 14.51 | 2738 | 795 | 3.91 / 947.75 | 6 | 54 |
6 | 13 | 1740.64 | 20 | 14.46 | 2560 | 740 | 4.65 / 948.49 | 6 | 57 |
7 | 13 | 1105.80 | 20 | 14.55 | 1758 | 512 | 5.16 / 949.00 | 6 | 69 |
8 | 13 | 801.44 | 20 | 14.62 | 1338 | 391 | 5.55 / 949.39 | 6 | 71 |
9 | 13 | 54.04 | 20 | 14.86 | 401 | 119 | 5.67 / 949.51 | 6 | 66 |
10 | 13 | 30.68 | 20 | 14.85 | 378 | 112 | 5.78 / 949.63 | 6 | 66 |
11 | 8 | -2.96 | 400 | 14.77 | 310 | 1831 | 7.61 / 951.46 | 6 | 116 |
Average= | 16.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 62 | 14.76 | 385 | 352 | 0.35 / 935.54 | 6 | 16 |
2 | 10 | 1068.20 | 8 | 14.77 | 1246 | 147 | 0.50 / 935.69 | 6 | 28 |
3 | 10 | 1140.72 | 7 | 14.70 | 1497 | 154 | 0.65 / 935.84 | 6 | 30 |
4 | 10 | 1202.12 | 6 | 14.69 | 1630 | 144 | 0.80 / 935.99 | 6 | 27 |
5 | 10 | 1249.08 | 4 | 14.64 | 1940 | 114 | 0.91 / 936.10 | 6 | 46 |
6 | 10 | 1281.52 | 3 | 14.64 | 2054 | 90 | 1.00 / 936.19 | 6 | 35 |
7 | 3 | 1305.88 | 8 | 14.97 | 614 | 74 | 1.07 / 936.27 | 6 | 44 |
8 | 7 | 2021.84 | 40 | 14.76 | 2393 | 1413 | 2.49 / 937.68 | 44 | 55 |
9 | 13 | 2069.36 | 20 | 14.70 | 2329 | 685 | 3.17 / 938.36 | 5 | 22 |
10 | 13 | 2048.36 | 20 | 14.63 | 2369 | 693 | 3.87 / 939.06 | 6 | 10 |
11 | 13 | 1992.52 | 20 | 14.61 | 2260 | 660 | 4.53 / 939.72 | 5 | 24 |
12 | 13 | 1912.96 | 20 | 14.50 | 2435 | 706 | 5.23 / 940.42 | 5 | 31 |
13 | 13 | 1715.44 | 20 | 14.42 | 2340 | 675 | 5.91 / 941.10 | 6 | 33 |
14 | 13 | 1172.20 | 20 | 14.57 | 1566 | 456 | 6.36 / 941.55 | 6 | 49 |
15 | 13 | 567.76 | 20 | 14.76 | 819 | 242 | 6.60 / 941.80 | 6 | 22 |
16 | 13 | 477.32 | 20 | 14.73 | 852 | 251 | 6.86 / 942.05 | 6 | 56 |
17 | 13 | 25.88 | 20 | 14.86 | 354 | 105 | 6.96 / 942.15 | 6 | 50 |
18 | 8 | -1.52 | 380 | 14.78 | 301 | 1691 | 8.65 / 943.84 | 6 | 89 |
Average= | 16.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 69 | 14.72 | 453 | 460 | 0.46 / 928.35 | 6 | 60 |
2 | 3 | 793.48 | -3 | 15.24 | 3 | 0 | 0.00 / 928.35 | 6 | 60 |
3 | 7 | 2006.24 | 40 | 14.62 | 2849 | 1666 | 2.13 / 930.01 | 60 | 47 |
4 | 13 | 1996.60 | 20 | 14.57 | 2873 | 837 | 2.96 / 930.85 | 6 | 52 |
5 | 13 | 1924.76 | 20 | 14.50 | 2799 | 812 | 3.78 / 931.66 | 6 | 56 |
6 | 13 | 1737.88 | 20 | 14.46 | 2573 | 744 | 4.52 / 932.41 | 6 | 58 |
7 | 13 | 1123.56 | 20 | 14.55 | 1771 | 515 | 5.03 / 932.92 | 6 | 68 |
8 | 13 | 596.36 | 20 | 14.69 | 1100 | 323 | 5.36 / 933.25 | 6 | 73 |
9 | 13 | 37.96 | 20 | 14.87 | 380 | 113 | 5.47 / 933.36 | 6 | 63 |
10 | 8 | -4.56 | 400 | 14.78 | 310 | 1833 | 7.30 / 935.19 | 6 | 109 |
Average= | 16.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 92 | 14.72 | 447 | 605 | 0.61 / 920.98 | 6 | 53 |
2 | 3 | 295.64 | -11 | 15.26 | 3 | 0 | 0.00 / 920.98 | 6 | 53 |
3 | 7 | 2006.64 | 40 | 14.64 | 2825 | 1654 | 2.26 / 922.63 | 53 | 50 |
4 | 13 | 1988.84 | 20 | 14.58 | 2836 | 827 | 3.09 / 923.46 | 6 | 52 |
5 | 13 | 1932.00 | 20 | 14.51 | 2769 | 804 | 3.89 / 924.26 | 5 | 54 |
6 | 13 | 1842.60 | 20 | 14.45 | 2669 | 771 | 4.66 / 925.03 | 6 | 58 |
7 | 13 | 1185.92 | 20 | 14.53 | 1843 | 536 | 5.20 / 925.57 | 6 | 67 |
8 | 13 | 657.52 | 20 | 14.67 | 1154 | 339 | 5.54 / 925.91 | 6 | 70 |
9 | 13 | 212.12 | 20 | 14.80 | 598 | 177 | 5.71 / 926.08 | 6 | 71 |
10 | 8 | -6.56 | 400 | 14.78 | 305 | 1803 | 7.52 / 927.89 | 6 | 98 |
Average= | 16.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 59 | 14.76 | 395 | 344 | 0.34 / 912.38 | 6 | 14 |
2 | 10 | 1046.52 | 9 | 14.73 | 1445 | 192 | 0.54 / 912.57 | 6 | 23 |
3 | 10 | 1129.00 | 8 | 14.94 | 524 | 63 | 0.60 / 912.63 | 6 | 34 |
4 | 10 | 1195.08 | 6 | 14.68 | 1472 | 130 | 0.73 / 912.76 | 6 | 52 |
5 | 10 | 1242.04 | 4 | 14.64 | 1939 | 114 | 0.84 / 912.88 | 6 | 46 |
6 | 3 | 1342.32 | 8 | 15.00 | 1109 | 133 | 0.97 / 913.01 | 6 | 45 |
7 | 7 | 2008.76 | 40 | 14.75 | 2387 | 1408 | 2.38 / 914.42 | 45 | 22 |
8 | 13 | 2063.16 | 20 | 14.65 | 2615 | 766 | 3.15 / 915.18 | 6 | 25 |
9 | 13 | 2033.00 | 20 | 14.64 | 2223 | 651 | 3.80 / 915.83 | 6 | 9 |
10 | 13 | 1973.68 | 20 | 14.61 | 2232 | 652 | 4.45 / 916.49 | 6 | 64 |
11 | 13 | 1886.16 | 20 | 14.60 | 2070 | 604 | 5.06 / 917.09 | 6 | 30 |
12 | 13 | 1580.84 | 20 | 14.52 | 1862 | 541 | 5.60 / 917.63 | 6 | 33 |
13 | 13 | 1390.80 | 20 | 14.58 | 1584 | 462 | 6.06 / 918.09 | 6 | 90 |
14 | 13 | 637.36 | 20 | 14.72 | 915 | 269 | 6.33 / 918.36 | 6 | 42 |
15 | 13 | 435.96 | 20 | 14.77 | 721 | 213 | 6.54 / 918.58 | 6 | 44 |
16 | 13 | 58.64 | 20 | 14.85 | 389 | 116 | 6.66 / 918.69 | 6 | 36 |
17 | 8 | -6.80 | 380 | 14.79 | 299 | 1680 | 8.34 / 920.37 | 6 | 69 |
Average= | 16.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 58 | 14.73 | 473 | 404 | 0.40 / 905.08 | 6 | 64 |
2 | 3 | 1022.72 | 1 | 14.91 | 1782 | 27 | 0.43 / 905.11 | 6 | 9 |
3 | 7 | 2006.24 | 40 | 14.62 | 2886 | 1688 | 2.12 / 906.80 | 9 | 55 |
4 | 13 | 1988.64 | 20 | 14.58 | 2862 | 835 | 2.95 / 907.63 | 6 | 54 |
5 | 13 | 1915.12 | 20 | 14.51 | 2803 | 813 | 3.77 / 908.45 | 6 | 57 |
6 | 13 | 1725.32 | 20 | 14.46 | 2566 | 742 | 4.51 / 909.19 | 6 | 59 |
7 | 13 | 1201.04 | 20 | 14.52 | 1908 | 554 | 5.06 / 909.74 | 6 | 68 |
8 | 13 | 650.12 | 20 | 14.67 | 1190 | 349 | 5.41 / 910.09 | 6 | 75 |
9 | 13 | 26.76 | 20 | 14.87 | 369 | 110 | 5.52 / 910.20 | 6 | 69 |
10 | 8 | -5.04 | 400 | 14.79 | 310 | 1834 | 7.36 / 912.03 | 6 | 81 |
Average= | 16.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 58 | 14.73 | 459 | 392 | 0.39 / 897.81 | 6 | 61 |
2 | 3 | 1022.08 | 1 | 14.93 | 1747 | 26 | 0.42 / 897.83 | 6 | 6 |
3 | 7 | 2006.36 | 40 | 14.63 | 2860 | 1674 | 2.09 / 899.51 | 6 | 51 |
4 | 13 | 2002.84 | 20 | 14.57 | 2912 | 849 | 2.94 / 900.35 | 6 | 53 |
5 | 13 | 1935.52 | 20 | 14.51 | 2806 | 814 | 3.75 / 901.17 | 6 | 56 |
6 | 13 | 1644.56 | 20 | 14.48 | 2446 | 708 | 4.46 / 901.88 | 6 | 59 |
7 | 13 | 1331.96 | 20 | 14.49 | 2053 | 595 | 5.06 / 902.47 | 6 | 65 |
8 | 13 | 694.56 | 20 | 14.66 | 1231 | 361 | 5.42 / 902.83 | 6 | 73 |
9 | 13 | 244.56 | 20 | 14.79 | 650 | 192 | 5.61 / 903.03 | 6 | 78 |
10 | 13 | 27.20 | 20 | 14.86 | 369 | 110 | 5.72 / 903.14 | 6 | 69 |
11 | 8 | -7.16 | 340 | 14.79 | 307 | 1544 | 7.26 / 904.68 | 6 | 133 |
Average= | 17.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 106 | 14.70 | 468 | 729 | 0.73 / 889.16 | 6 | 59 |
2 | 2 | 187.48 | 27 | 14.80 | 600 | 240 | 0.97 / 889.40 | 6 | 58 |
3 | 10 | 1007.56 | 8 | 14.73 | 1631 | 192 | 1.16 / 889.59 | 6 | 58 |
4 | 10 | 1091.72 | 8 | 14.70 | 1754 | 206 | 1.37 / 889.80 | 6 | 58 |
5 | 10 | 1167.84 | 7 | 14.67 | 1858 | 191 | 1.56 / 889.99 | 6 | 59 |
6 | 10 | 1220.64 | 5 | 14.67 | 1936 | 142 | 1.70 / 890.13 | 6 | 54 |
7 | 10 | 1250.28 | 3 | 14.66 | 2024 | 89 | 1.79 / 890.22 | 6 | 42 |
8 | 3 | 1196.36 | 5 | 14.76 | 1904 | 141 | 1.93 / 890.36 | 6 | 60 |
9 | 7 | 2014.92 | 40 | 14.63 | 2854 | 1670 | 3.60 / 892.03 | 60 | 48 |
10 | 13 | 2007.44 | 20 | 14.58 | 2886 | 842 | 4.44 / 892.87 | 6 | 52 |
11 | 13 | 1943.20 | 20 | 14.50 | 2823 | 819 | 5.26 / 893.69 | 6 | 55 |
12 | 13 | 1849.20 | 20 | 14.46 | 2693 | 779 | 6.04 / 894.47 | 6 | 57 |
13 | 13 | 1400.04 | 20 | 14.48 | 2131 | 617 | 6.66 / 895.09 | 6 | 64 |
14 | 13 | 697.12 | 20 | 14.65 | 1227 | 360 | 7.02 / 895.45 | 6 | 74 |
15 | 13 | 154.28 | 20 | 14.83 | 533 | 158 | 7.17 / 895.60 | 6 | 73 |
16 | 8 | -6.60 | 400 | 14.79 | 306 | 1810 | 8.98 / 897.41 | 6 | 69 |
Average= | 17.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 56 | 14.77 | 400 | 331 | 0.33 / 879.62 | 6 | 7 |
2 | 10 | 1079.28 | 11 | 14.80 | 1171 | 191 | 0.52 / 879.82 | 6 | 26 |
3 | 10 | 1169.00 | 8 | 14.78 | 1256 | 149 | 0.67 / 879.96 | 6 | 52 |
4 | 10 | 1233.64 | 6 | 14.66 | 1666 | 147 | 0.82 / 880.11 | 6 | 28 |
5 | 10 | 1296.40 | 6 | 14.76 | 1494 | 132 | 0.95 / 880.24 | 6 | 42 |
6 | 10 | 1357.40 | 6 | 14.63 | 1982 | 174 | 1.12 / 880.42 | 6 | 51 |
7 | 10 | 1408.00 | 5 | 14.59 | 2120 | 155 | 1.28 / 880.57 | 6 | 48 |
8 | 10 | 1440.04 | 3 | 14.59 | 2253 | 99 | 1.38 / 880.67 | 6 | 33 |
9 | 3 | 1392.88 | 10 | 15.02 | 526 | 79 | 1.46 / 880.75 | 6 | 12 |
10 | 7 | 2023.92 | 40 | 14.86 | 2113 | 1256 | 2.71 / 882.01 | 12 | 68 |
11 | 13 | 2084.92 | 20 | 14.80 | 2148 | 636 | 3.35 / 882.64 | 6 | 16 |
12 | 13 | 2096.12 | 20 | 14.63 | 2533 | 741 | 4.09 / 883.38 | 6 | 26 |
13 | 13 | 2040.96 | 20 | 14.57 | 2458 | 716 | 4.80 / 884.10 | 6 | 25 |
14 | 13 | 1960.16 | 20 | 14.48 | 2534 | 734 | 5.54 / 884.83 | 6 | 33 |
15 | 13 | 1864.92 | 20 | 14.45 | 2223 | 642 | 6.18 / 885.47 | 6 | 36 |
16 | 13 | 1155.84 | 20 | 14.57 | 1571 | 458 | 6.64 / 885.93 | 6 | 46 |
17 | 13 | 961.04 | 20 | 14.60 | 1366 | 399 | 7.04 / 886.33 | 6 | 38 |
18 | 13 | 541.88 | 20 | 14.73 | 858 | 253 | 7.29 / 886.58 | 6 | 22 |
19 | 13 | 60.88 | 20 | 14.85 | 392 | 116 | 7.41 / 886.70 | 6 | 42 |
20 | 8 | -6.60 | 380 | 14.78 | 308 | 1730 | 9.14 / 888.43 | 6 | 104 |
Average= | 17.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 74 | 14.73 | 446 | 486 | 0.49 / 872.33 | 6 | 56 |
2 | 3 | 459.76 | -8 | 15.26 | 3 | 0 | 0.00 / 872.33 | 6 | 56 |
3 | 7 | 2014.24 | 40 | 14.63 | 2873 | 1681 | 2.17 / 874.01 | 56 | 50 |
4 | 13 | 2010.04 | 20 | 14.57 | 2900 | 845 | 3.01 / 874.86 | 6 | 54 |
5 | 13 | 1942.24 | 20 | 14.51 | 2797 | 812 | 3.82 / 875.67 | 6 | 54 |
6 | 13 | 1752.80 | 20 | 14.46 | 2584 | 747 | 4.57 / 876.42 | 6 | 58 |
7 | 13 | 1338.20 | 20 | 14.50 | 2055 | 596 | 5.17 / 877.01 | 6 | 66 |
8 | 13 | 658.24 | 20 | 14.67 | 1187 | 348 | 5.52 / 877.36 | 6 | 77 |
9 | 13 | 23.92 | 20 | 14.87 | 368 | 109 | 5.63 / 877.47 | 6 | 69 |
10 | 8 | -6.68 | 400 | 14.79 | 308 | 1822 | 7.45 / 879.29 | 6 | 113 |
Average= | 17.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 68 | 14.75 | 424 | 425 | 0.43 / 864.62 | 6 | 32 |
2 | 10 | 1026.64 | 4 | 14.77 | 1674 | 99 | 0.52 / 864.72 | 6 | 50 |
3 | 3 | 1088.36 | 2 | 14.85 | 1788 | 53 | 0.58 / 864.77 | 6 | 32 |
4 | 7 | 2024.64 | 41 | 14.62 | 2857 | 1713 | 2.29 / 866.49 | 32 | 52 |
5 | 13 | 2010.32 | 20 | 14.59 | 2828 | 825 | 3.12 / 867.31 | 6 | 52 |
6 | 13 | 1936.56 | 20 | 14.52 | 2760 | 802 | 3.92 / 868.11 | 6 | 54 |
7 | 13 | 1736.28 | 20 | 14.48 | 2501 | 724 | 4.64 / 868.84 | 6 | 58 |
8 | 13 | 1540.72 | 20 | 14.45 | 2271 | 656 | 5.30 / 869.49 | 6 | 61 |
9 | 13 | 771.68 | 20 | 14.64 | 1294 | 379 | 5.68 / 869.87 | 6 | 70 |
10 | 13 | 135.72 | 20 | 14.84 | 489 | 145 | 5.82 / 870.02 | 6 | 69 |
11 | 8 | -5.20 | 400 | 14.79 | 309 | 1828 | 7.65 / 871.85 | 6 | 110 |
Average= | 17.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 90 | 14.71 | 465 | 616 | 0.62 / 856.26 | 6 | 54 |
2 | 3 | 52.92 | -15 | 15.30 | 3 | 0 | 0.00 / 856.26 | 6 | 54 |
3 | 5 | 1440.36 | 11 | 14.85 | 2076 | 339 | 0.95 / 856.60 | 5 | 56 |
4 | 5 | 1596.12 | 15 | 14.74 | 2359 | 522 | 1.48 / 857.12 | 6 | 57 |
5 | 7 | 2007.68 | 40 | 14.62 | 2863 | 1674 | 3.15 / 858.80 | 57 | 49 |
6 | 13 | 2008.36 | 20 | 14.57 | 2896 | 844 | 3.99 / 859.64 | 6 | 51 |
7 | 13 | 1946.16 | 20 | 14.51 | 2792 | 810 | 4.80 / 860.45 | 6 | 53 |
8 | 13 | 1854.00 | 20 | 14.45 | 2688 | 777 | 5.58 / 861.23 | 6 | 57 |
9 | 13 | 1446.20 | 20 | 14.47 | 2171 | 628 | 6.21 / 861.86 | 6 | 63 |
10 | 13 | 765.44 | 20 | 14.63 | 1337 | 391 | 6.60 / 862.25 | 6 | 72 |
11 | 13 | 54.20 | 20 | 14.87 | 403 | 120 | 6.72 / 862.37 | 6 | 66 |
12 | 8 | -6.84 | 400 | 14.80 | 309 | 1829 | 8.55 / 864.20 | 6 | 79 |
Average= | 18.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 56 | 14.76 | 345 | 285 | 0.29 / 847.79 | 6 | 6 |
2 | 10 | 1101.64 | 9 | 14.91 | 911 | 122 | 0.41 / 847.91 | 6 | 23 |
3 | 10 | 1179.08 | 7 | 14.90 | 707 | 74 | 0.48 / 847.98 | 6 | 53 |
4 | 10 | 1235.16 | 5 | 14.66 | 1872 | 137 | 0.62 / 848.12 | 6 | 47 |
5 | 10 | 1272.08 | 3 | 14.65 | 1987 | 87 | 0.71 / 848.21 | 6 | 39 |
6 | 3 | 1430.40 | 11 | 15.08 | 422 | 70 | 0.78 / 848.28 | 6 | 6 |
7 | 7 | 2008.72 | 40 | 14.77 | 2372 | 1401 | 2.18 / 849.68 | 6 | 25 |
8 | 13 | 2061.64 | 20 | 14.71 | 2315 | 681 | 2.86 / 850.36 | 6 | 22 |
9 | 13 | 2028.96 | 20 | 14.64 | 2366 | 693 | 3.55 / 851.05 | 6 | 79 |
10 | 13 | 1958.12 | 20 | 14.78 | 1536 | 454 | 4.00 / 851.51 | 6 | 6 |
11 | 13 | 1876.16 | 20 | 14.53 | 2237 | 650 | 4.66 / 852.16 | 6 | 36 |
12 | 13 | 1685.60 | 20 | 14.53 | 1952 | 567 | 5.22 / 852.73 | 6 | 31 |
13 | 13 | 1487.92 | 20 | 14.58 | 1651 | 481 | 5.70 / 853.21 | 6 | 39 |
14 | 13 | 849.32 | 20 | 14.71 | 1046 | 308 | 6.01 / 853.51 | 6 | 37 |
15 | 13 | 540.76 | 20 | 14.74 | 808 | 238 | 6.25 / 853.75 | 6 | 18 |
16 | 13 | 343.64 | 20 | 14.79 | 631 | 187 | 6.44 / 853.94 | 6 | 40 |
17 | 13 | 29.88 | 20 | 14.86 | 358 | 106 | 6.54 / 854.05 | 6 | 35 |
18 | 8 | -3.64 | 360 | 14.78 | 301 | 1602 | 8.14 / 855.65 | 6 | 90 |
Average= | 18.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 86 | 14.73 | 460 | 583 | 0.58 / 840.67 | 6 | 53 |
2 | 3 | 61.36 | -15 | 15.30 | 3 | 0 | 0.00 / 840.67 | 6 | 53 |
3 | 7 | 2023.76 | 40 | 14.63 | 2842 | 1663 | 2.25 / 842.33 | 53 | 48 |
4 | 13 | 2001.88 | 20 | 14.58 | 2875 | 838 | 3.08 / 843.17 | 6 | 52 |
5 | 13 | 1931.84 | 20 | 14.52 | 2801 | 813 | 3.90 / 843.98 | 6 | 54 |
6 | 13 | 1839.32 | 20 | 14.46 | 2648 | 766 | 4.66 / 844.75 | 6 | 58 |
7 | 13 | 1112.96 | 20 | 14.55 | 1765 | 514 | 5.18 / 845.26 | 6 | 68 |
8 | 13 | 592.48 | 20 | 14.68 | 1099 | 323 | 5.50 / 845.58 | 6 | 74 |
9 | 13 | 67.20 | 20 | 14.85 | 416 | 124 | 5.62 / 845.71 | 6 | 66 |
10 | 8 | -6.72 | 400 | 14.78 | 304 | 1797 | 7.42 / 847.50 | 6 | 95 |
Average= | 18.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 53 | 14.76 | 361 | 282 | 0.28 / 832.02 | 6 | 6 |
2 | 10 | 1103.04 | 8 | 14.90 | 509 | 61 | 0.34 / 832.08 | 6 | 35 |
3 | 10 | 1173.36 | 6 | 14.88 | 810 | 72 | 0.42 / 832.15 | 6 | 52 |
4 | 10 | 1236.68 | 6 | 14.67 | 1802 | 159 | 0.57 / 832.31 | 6 | 49 |
5 | 10 | 1288.32 | 5 | 14.67 | 1959 | 144 | 0.72 / 832.45 | 6 | 46 |
6 | 10 | 1321.84 | 3 | 14.65 | 2070 | 91 | 0.81 / 832.54 | 6 | 35 |
7 | 3 | 1327.76 | 8 | 14.86 | 1152 | 137 | 0.95 / 832.68 | 6 | 29 |
8 | 7 | 2018.04 | 40 | 14.80 | 2330 | 1379 | 2.32 / 834.06 | 29 | 58 |
9 | 13 | 2052.44 | 20 | 14.64 | 2660 | 779 | 3.10 / 834.84 | 5 | 23 |
10 | 13 | 2006.28 | 20 | 14.63 | 2465 | 721 | 3.83 / 835.56 | 6 | 45 |
11 | 13 | 1935.92 | 20 | 14.51 | 2599 | 754 | 4.58 / 836.31 | 6 | 27 |
12 | 13 | 1845.08 | 20 | 14.51 | 2340 | 679 | 5.26 / 836.99 | 6 | 90 |
13 | 13 | 1428.28 | 20 | 14.50 | 1911 | 554 | 5.81 / 837.55 | 6 | 36 |
14 | 13 | 803.72 | 20 | 14.67 | 1165 | 342 | 6.15 / 837.89 | 6 | 27 |
15 | 13 | 603.92 | 20 | 14.74 | 855 | 252 | 6.41 / 838.14 | 6 | 21 |
16 | 13 | 164.04 | 20 | 14.84 | 473 | 140 | 6.55 / 838.28 | 6 | 43 |
17 | 13 | 33.52 | 20 | 14.86 | 368 | 109 | 6.66 / 838.39 | 6 | 47 |
18 | 8 | -6.68 | 380 | 14.79 | 301 | 1692 | 8.35 / 840.08 | 6 | 104 |
Average= | 18.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 83 | 14.73 | 480 | 587 | 0.59 / 824.78 | 6 | 51 |
2 | 3 | 58.08 | -15 | 15.29 | 3 | 0 | 0.00 / 824.78 | 6 | 51 |
3 | 7 | 2007.12 | 40 | 14.64 | 2834 | 1660 | 2.25 / 826.44 | 51 | 48 |
4 | 13 | 1995.60 | 20 | 14.59 | 2842 | 829 | 3.08 / 827.27 | 5 | 53 |
5 | 13 | 1916.96 | 20 | 14.52 | 2759 | 801 | 3.88 / 828.07 | 6 | 54 |
6 | 13 | 1704.64 | 20 | 14.49 | 2501 | 725 | 4.60 / 828.79 | 6 | 60 |
7 | 13 | 1509.28 | 20 | 14.46 | 2269 | 656 | 5.26 / 829.45 | 6 | 62 |
8 | 13 | 713.36 | 20 | 14.64 | 1250 | 366 | 5.62 / 829.81 | 6 | 73 |
9 | 13 | 82.80 | 20 | 14.85 | 433 | 129 | 5.75 / 829.94 | 6 | 69 |
10 | 8 | -3.12 | 400 | 14.78 | 303 | 1791 | 7.54 / 831.73 | 6 | 77 |
Average= | 18.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 58 | 14.78 | 395 | 339 | 0.34 / 816.14 | 6 | 10 |
2 | 10 | 1055.24 | 8 | 14.90 | 958 | 114 | 0.45 / 816.26 | 6 | 44 |
3 | 10 | 1124.48 | 6 | 14.77 | 1042 | 92 | 0.55 / 816.35 | 6 | 46 |
4 | 10 | 1175.32 | 5 | 14.68 | 1888 | 139 | 0.68 / 816.49 | 6 | 49 |
5 | 10 | 1208.44 | 3 | 14.69 | 1945 | 86 | 0.77 / 816.57 | 6 | 36 |
6 | 3 | 1249.48 | 6 | 14.96 | 1004 | 90 | 0.86 / 816.66 | 5 | 65 |
7 | 7 | 2009.24 | 40 | 14.88 | 1985 | 1181 | 2.04 / 817.85 | 65 | 6 |
8 | 13 | 2079.68 | 20 | 14.68 | 2562 | 752 | 2.79 / 818.60 | 5 | 53 |
9 | 13 | 2075.36 | 20 | 14.59 | 2584 | 754 | 3.55 / 819.35 | 6 | 26 |
10 | 13 | 2016.08 | 20 | 14.57 | 2481 | 723 | 4.27 / 820.07 | 6 | 39 |
11 | 13 | 1929.08 | 20 | 14.44 | 2666 | 770 | 5.04 / 820.84 | 6 | 35 |
12 | 13 | 1616.16 | 20 | 14.47 | 2104 | 609 | 5.65 / 821.45 | 6 | 49 |
13 | 13 | 1196.52 | 20 | 14.61 | 1452 | 424 | 6.07 / 821.88 | 6 | 28 |
14 | 13 | 783.28 | 20 | 14.66 | 1145 | 336 | 6.41 / 822.21 | 6 | 34 |
15 | 13 | 248.72 | 20 | 14.81 | 584 | 173 | 6.58 / 822.39 | 6 | 39 |
16 | 13 | 31.28 | 20 | 14.86 | 362 | 108 | 6.69 / 822.49 | 6 | 36 |
17 | 8 | -6.80 | 380 | 14.79 | 302 | 1697 | 8.39 / 824.19 | 6 | 111 |
Average= | 19.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 57 | 14.75 | 453 | 381 | 0.38 / 811.06 | 6 | 42 |
2 | 3 | 1063.92 | 2 | 14.87 | 1789 | 53 | 0.43 / 811.12 | 6 | 25 |
3 | 7 | 1736.48 | 40 | 14.74 | 2470 | 1456 | 1.89 / 812.57 | 25 | 60 |
4 | 13 | 1440.48 | 20 | 14.74 | 2149 | 634 | 2.52 / 813.21 | 6 | 65 |
5 | 13 | 913.00 | 20 | 14.76 | 1476 | 436 | 2.96 / 813.64 | 6 | 70 |
6 | 13 | 379.64 | 20 | 14.84 | 788 | 234 | 3.19 / 813.88 | 6 | 70 |
7 | 13 | 31.88 | 20 | 14.91 | 375 | 112 | 3.31 / 813.99 | 6 | 72 |
8 | 8 | -6.56 | 400 | 14.83 | 306 | 1815 | 5.12 / 815.80 | 6 | 79 |
Average= | 19.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 57 | 14.74 | 486 | 408 | 0.41 / 804.05 | 6 | 52 |
2 | 7 | 2021.56 | 40 | 14.63 | 2862 | 1675 | 2.08 / 805.72 | 52 | 49 |
3 | 13 | 1982.84 | 20 | 14.59 | 2848 | 831 | 2.91 / 806.55 | 6 | 52 |
4 | 13 | 1904.28 | 20 | 14.52 | 2784 | 808 | 3.72 / 807.36 | 6 | 57 |
5 | 13 | 1708.72 | 20 | 14.48 | 2533 | 734 | 4.46 / 808.09 | 6 | 62 |
6 | 13 | 1169.92 | 20 | 14.55 | 1838 | 535 | 4.99 / 808.63 | 6 | 69 |
7 | 13 | 321.16 | 20 | 14.79 | 765 | 226 | 5.22 / 808.85 | 6 | 81 |
8 | 8 | -6.88 | 400 | 14.80 | 309 | 1829 | 7.05 / 810.68 | 6 | 80 |
Average= | 19.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 86 | 14.73 | 457 | 579 | 0.58 / 796.82 | 6 | 52 |
2 | 3 | 120.68 | -14 | 15.28 | 3 | 0 | 0.00 / 796.82 | 6 | 52 |
3 | 7 | 2026.60 | 40 | 14.64 | 2834 | 1660 | 2.24 / 798.48 | 52 | 51 |
4 | 13 | 2013.68 | 20 | 14.59 | 2881 | 841 | 3.08 / 799.32 | 6 | 52 |
5 | 13 | 1943.92 | 20 | 14.51 | 2801 | 813 | 3.89 / 800.13 | 6 | 56 |
6 | 13 | 1748.08 | 20 | 14.48 | 2546 | 737 | 4.63 / 800.87 | 6 | 57 |
7 | 13 | 1223.20 | 20 | 14.54 | 1894 | 551 | 5.18 / 801.42 | 6 | 65 |
8 | 13 | 684.56 | 20 | 14.66 | 1217 | 357 | 5.54 / 801.78 | 6 | 74 |
9 | 13 | 66.12 | 20 | 14.86 | 416 | 124 | 5.66 / 801.90 | 6 | 70 |
10 | 8 | -3.64 | 381 | 14.79 | 308 | 1736 | 7.40 / 803.64 | 6 | 132 |
Average= | 20.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 61 | 14.77 | 389 | 350 | 0.35 / 788.22 | 6 | 12 |
2 | 10 | 1027.12 | 8 | 14.88 | 720 | 86 | 0.44 / 788.30 | 6 | 36 |
3 | 10 | 1095.44 | 6 | 14.73 | 1598 | 141 | 0.58 / 788.45 | 6 | 49 |
4 | 10 | 1149.52 | 5 | 14.69 | 1786 | 131 | 0.71 / 788.58 | 6 | 48 |
5 | 10 | 1187.72 | 4 | 14.68 | 1864 | 109 | 0.82 / 788.69 | 6 | 41 |
6 | 3 | 1233.24 | 6 | 14.80 | 1838 | 163 | 0.98 / 788.85 | 6 | 57 |
7 | 7 | 2007.60 | 40 | 14.78 | 2396 | 1417 | 2.40 / 790.27 | 57 | 20 |
8 | 13 | 2056.12 | 20 | 14.76 | 2288 | 675 | 3.07 / 790.94 | 5 | 45 |
9 | 13 | 2022.48 | 20 | 14.66 | 2299 | 674 | 3.75 / 791.62 | 6 | 31 |
10 | 13 | 1954.28 | 20 | 14.60 | 2240 | 654 | 4.40 / 792.27 | 6 | 29 |
11 | 13 | 1872.56 | 20 | 14.57 | 2150 | 627 | 5.03 / 792.90 | 5 | 29 |
12 | 13 | 1781.60 | 20 | 14.59 | 1950 | 569 | 5.60 / 793.47 | 6 | 33 |
13 | 13 | 1162.80 | 20 | 14.65 | 1296 | 380 | 5.98 / 793.85 | 6 | 24 |
14 | 13 | 964.24 | 20 | 14.65 | 1225 | 359 | 6.34 / 794.20 | 5 | 46 |
15 | 13 | 448.72 | 20 | 14.77 | 689 | 204 | 6.54 / 794.41 | 6 | 20 |
16 | 13 | 78.92 | 20 | 14.86 | 400 | 119 | 6.66 / 794.53 | 6 | 37 |
17 | 8 | -6.76 | 380 | 14.79 | 305 | 1714 | 8.37 / 796.24 | 6 | 67 |
Average= | 20.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 60 | 14.75 | 461 | 408 | 0.41 / 781.02 | 6 | 59 |
2 | 3 | 1032.64 | 1 | 14.91 | 1780 | 27 | 0.43 / 781.05 | 5 | 9 |
3 | 7 | 2005.80 | 40 | 14.65 | 2839 | 1664 | 2.10 / 782.71 | 9 | 55 |
4 | 13 | 1990.44 | 20 | 14.61 | 2852 | 833 | 2.93 / 783.54 | 5 | 52 |
5 | 13 | 1914.88 | 20 | 14.53 | 2773 | 806 | 3.74 / 784.35 | 6 | 58 |
6 | 13 | 1729.84 | 20 | 14.49 | 2543 | 737 | 4.47 / 785.09 | 6 | 60 |
7 | 13 | 1019.68 | 20 | 14.60 | 1651 | 482 | 4.96 / 785.57 | 6 | 70 |
8 | 13 | 723.04 | 20 | 14.66 | 1274 | 374 | 5.33 / 785.94 | 6 | 76 |
9 | 13 | 42.48 | 20 | 14.88 | 388 | 115 | 5.45 / 786.06 | 6 | 72 |
10 | 8 | -6.60 | 400 | 14.80 | 306 | 1812 | 7.26 / 787.87 | 6 | 97 |
Average= | 20.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 61 | 14.74 | 470 | 423 | 0.42 / 773.79 | 6 | 55 |
2 | 3 | 956.80 | -1 | 15.26 | 3 | 0 | 0.00 / 773.79 | 6 | 55 |
3 | 7 | 2013.40 | 40 | 14.64 | 2870 | 1681 | 2.10 / 775.47 | 55 | 54 |
4 | 13 | 2006.24 | 20 | 14.59 | 2894 | 844 | 2.95 / 776.31 | 6 | 54 |
5 | 13 | 1935.68 | 20 | 14.52 | 2802 | 814 | 3.76 / 777.13 | 6 | 55 |
6 | 13 | 1744.04 | 20 | 14.49 | 2538 | 736 | 4.50 / 777.86 | 6 | 60 |
7 | 13 | 1222.92 | 20 | 14.54 | 1919 | 558 | 5.05 / 778.42 | 6 | 69 |
8 | 13 | 702.00 | 20 | 14.67 | 1238 | 363 | 5.42 / 778.78 | 6 | 76 |
9 | 13 | 72.88 | 20 | 14.87 | 428 | 127 | 5.55 / 778.91 | 6 | 73 |
10 | 8 | -4.64 | 366 | 14.80 | 314 | 1701 | 7.25 / 780.61 | 6 | 130 |
Average= | 21.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 63 | 14.73 | 487 | 452 | 0.45 / 766.63 | 6 | 62 |
2 | 3 | 951.88 | -1 | 15.26 | 3 | 0 | 0.00 / 766.63 | 6 | 62 |
3 | 7 | 2008.88 | 40 | 14.64 | 2880 | 1687 | 2.14 / 768.32 | 62 | 56 |
4 | 13 | 1994.24 | 20 | 14.59 | 2900 | 846 | 2.98 / 769.17 | 6 | 55 |
5 | 13 | 1925.12 | 20 | 14.52 | 2822 | 820 | 3.80 / 769.99 | 6 | 58 |
6 | 13 | 1629.80 | 20 | 14.50 | 2440 | 708 | 4.51 / 770.69 | 6 | 63 |
7 | 13 | 1107.12 | 20 | 14.58 | 1767 | 515 | 5.03 / 771.21 | 6 | 69 |
8 | 13 | 571.80 | 20 | 14.71 | 1099 | 323 | 5.35 / 771.53 | 6 | 83 |
9 | 8 | -3.08 | 398 | 14.81 | 311 | 1833 | 7.18 / 773.37 | 6 | 149 |
Average= | 21.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 90 | 14.71 | 464 | 614 | 0.61 / 759.37 | 6 | 60 |
2 | 3 | 176.60 | -13 | 15.26 | 4 | 0 | 0.00 / 759.37 | 6 | 60 |
3 | 7 | 2025.08 | 40 | 14.64 | 2874 | 1683 | 2.30 / 761.05 | 60 | 51 |
4 | 13 | 2006.24 | 20 | 14.59 | 2889 | 843 | 3.14 / 761.90 | 6 | 54 |
5 | 13 | 1934.80 | 20 | 14.53 | 2814 | 818 | 3.96 / 762.71 | 6 | 57 |
6 | 13 | 1633.28 | 20 | 14.51 | 2409 | 699 | 4.66 / 763.41 | 6 | 62 |
7 | 13 | 1227.36 | 20 | 14.54 | 1909 | 555 | 5.21 / 763.97 | 6 | 67 |
8 | 13 | 675.56 | 20 | 14.68 | 1198 | 352 | 5.56 / 764.32 | 6 | 75 |
9 | 13 | 13.76 | 20 | 14.89 | 358 | 107 | 5.67 / 764.43 | 6 | 70 |
10 | 8 | -4.84 | 379 | 14.80 | 313 | 1756 | 7.43 / 766.18 | 6 | 131 |
Average= | 21.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 82 | 14.75 | 425 | 514 | 0.51 / 751.03 | 6 | 37 |
2 | 10 | 1036.56 | 4 | 14.83 | 1359 | 81 | 0.59 / 751.11 | 6 | 35 |
3 | 3 | 1154.92 | 4 | 15.02 | 1228 | 74 | 0.67 / 751.18 | 6 | 45 |
4 | 7 | 2024.88 | 40 | 14.80 | 2290 | 1356 | 2.02 / 752.54 | 45 | 40 |
5 | 13 | 2079.20 | 20 | 14.71 | 2440 | 718 | 2.74 / 753.26 | 6 | 30 |
6 | 13 | 2053.00 | 20 | 14.64 | 2402 | 703 | 3.45 / 753.96 | 6 | 52 |
7 | 13 | 1990.00 | 20 | 14.61 | 2312 | 676 | 4.12 / 754.64 | 6 | 30 |
8 | 13 | 1905.92 | 20 | 14.58 | 2197 | 641 | 4.76 / 755.28 | 6 | 28 |
9 | 13 | 1706.44 | 20 | 14.52 | 2068 | 601 | 5.36 / 755.88 | 6 | 49 |
10 | 13 | 1289.68 | 20 | 14.59 | 1571 | 458 | 5.82 / 756.34 | 6 | 39 |
11 | 13 | 772.96 | 20 | 14.64 | 1329 | 389 | 6.21 / 756.73 | 6 | 72 |
12 | 13 | 352.76 | 20 | 14.77 | 791 | 234 | 6.44 / 756.96 | 6 | 77 |
13 | 8 | -6.48 | 393 | 14.79 | 309 | 1796 | 8.24 / 758.76 | 6 | 134 |
Average= | 22.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 61 | 14.76 | 405 | 365 | 0.36 / 743.03 | 6 | 25 |
2 | 10 | 1021.88 | 8 | 14.72 | 1535 | 181 | 0.55 / 743.21 | 6 | 61 |
3 | 10 | 1089.88 | 6 | 14.70 | 1648 | 145 | 0.69 / 743.36 | 6 | 56 |
4 | 10 | 1143.60 | 5 | 14.68 | 1791 | 131 | 0.82 / 743.49 | 6 | 52 |
5 | 3 | 1227.76 | 6 | 14.79 | 1873 | 166 | 0.99 / 743.65 | 6 | 57 |
6 | 7 | 2005.72 | 40 | 14.67 | 2792 | 1638 | 2.63 / 745.29 | 57 | 48 |
7 | 13 | 1994.64 | 20 | 14.61 | 2849 | 832 | 3.46 / 746.12 | 6 | 52 |
8 | 13 | 1920.84 | 20 | 14.56 | 2710 | 789 | 4.25 / 746.91 | 6 | 55 |
9 | 13 | 1726.36 | 20 | 14.52 | 2506 | 728 | 4.98 / 747.64 | 6 | 58 |
10 | 13 | 1310.76 | 20 | 14.54 | 1970 | 573 | 5.55 / 748.21 | 6 | 64 |
11 | 13 | 760.52 | 20 | 14.67 | 1247 | 366 | 5.91 / 748.58 | 6 | 63 |
12 | 13 | 12.00 | 20 | 14.90 | 353 | 105 | 6.02 / 748.69 | 6 | 73 |
13 | 8 | -6.72 | 400 | 14.81 | 309 | 1831 | 7.85 / 750.52 | 6 | 72 |
Average= | 22.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 63 | 14.74 | 478 | 444 | 0.44 / 735.75 | 6 | 64 |
2 | 3 | 933.16 | -1 | 15.27 | 3 | 0 | 0.00 / 735.75 | 6 | 64 |
3 | 7 | 2012.16 | 40 | 14.64 | 2920 | 1710 | 2.15 / 737.46 | 64 | 52 |
4 | 13 | 1997.40 | 20 | 14.59 | 2937 | 857 | 3.01 / 738.32 | 6 | 55 |
5 | 13 | 1921.96 | 20 | 14.52 | 2816 | 818 | 3.83 / 739.14 | 6 | 57 |
6 | 13 | 1717.72 | 20 | 14.50 | 2544 | 738 | 4.57 / 739.87 | 6 | 62 |
7 | 13 | 1095.40 | 20 | 14.58 | 1763 | 514 | 5.08 / 740.39 | 6 | 72 |
8 | 13 | 455.72 | 20 | 14.75 | 952 | 281 | 5.36 / 740.67 | 6 | 82 |
9 | 13 | 57.80 | 20 | 14.88 | 421 | 125 | 5.49 / 740.79 | 6 | 74 |
10 | 8 | -6.84 | 400 | 14.80 | 316 | 1871 | 7.36 / 742.67 | 6 | 82 |
Average= | 23.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 63 | 14.74 | 465 | 432 | 0.43 / 728.52 | 6 | 66 |
2 | 7 | 2024.64 | 40 | 14.64 | 2907 | 1702 | 2.13 / 730.22 | 66 | 50 |
3 | 13 | 2007.36 | 20 | 14.60 | 2892 | 844 | 2.98 / 731.06 | 6 | 56 |
4 | 13 | 1935.24 | 20 | 14.52 | 2844 | 826 | 3.80 / 731.89 | 6 | 58 |
5 | 13 | 1642.08 | 20 | 14.50 | 2467 | 715 | 4.52 / 732.61 | 6 | 63 |
6 | 13 | 1434.08 | 20 | 14.49 | 2182 | 632 | 5.15 / 733.24 | 6 | 69 |
7 | 13 | 552.84 | 20 | 14.73 | 1058 | 312 | 5.46 / 733.55 | 6 | 77 |
8 | 8 | -6.56 | 379 | 14.82 | 313 | 1758 | 7.22 / 735.31 | 6 | 130 |
Average= | 23.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 64 | 14.74 | 472 | 445 | 0.45 / 721.36 | 6 | 65 |
2 | 7 | 2006.72 | 40 | 14.64 | 2904 | 1701 | 2.15 / 723.06 | 65 | 52 |
3 | 13 | 1986.72 | 20 | 14.61 | 2876 | 840 | 2.99 / 723.90 | 6 | 55 |
4 | 13 | 1909.24 | 20 | 14.54 | 2800 | 814 | 3.80 / 724.71 | 5 | 58 |
5 | 13 | 1707.44 | 20 | 14.50 | 2513 | 729 | 4.53 / 725.44 | 6 | 62 |
6 | 13 | 1295.52 | 20 | 14.52 | 2029 | 589 | 5.12 / 726.03 | 6 | 68 |
7 | 13 | 442.20 | 20 | 14.76 | 931 | 275 | 5.39 / 726.31 | 6 | 83 |
8 | 8 | -6.52 | 385 | 14.82 | 312 | 1780 | 7.17 / 728.09 | 6 | 130 |
Average= | 24.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 61 | 14.75 | 441 | 397 | 0.40 / 714.06 | 6 | 60 |
2 | 3 | 1110.08 | 3 | 14.86 | 1814 | 81 | 0.48 / 714.14 | 6 | 48 |
3 | 7 | 2024.56 | 40 | 14.65 | 2906 | 1703 | 2.18 / 715.85 | 48 | 51 |
4 | 13 | 2014.36 | 20 | 14.59 | 2932 | 856 | 3.04 / 716.70 | 6 | 55 |
5 | 13 | 1939.20 | 20 | 14.54 | 2839 | 826 | 3.86 / 717.53 | 6 | 58 |
6 | 13 | 1643.56 | 20 | 14.51 | 2457 | 713 | 4.57 / 718.24 | 6 | 61 |
7 | 13 | 1229.24 | 20 | 14.55 | 1912 | 556 | 5.13 / 718.80 | 6 | 68 |
8 | 13 | 584.72 | 20 | 14.72 | 1112 | 327 | 5.46 / 719.12 | 6 | 82 |
9 | 8 | -3.52 | 387 | 14.82 | 312 | 1789 | 7.25 / 720.91 | 6 | 132 |
Average= | 24.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 63 | 14.74 | 461 | 428 | 0.43 / 706.91 | 6 | 66 |
2 | 3 | 947.20 | -1 | 15.27 | 3 | 0 | 0.00 / 706.91 | 6 | 66 |
3 | 7 | 2006.40 | 40 | 14.65 | 2880 | 1688 | 2.12 / 708.60 | 66 | 52 |
4 | 13 | 1989.68 | 20 | 14.60 | 2907 | 849 | 2.96 / 709.44 | 6 | 56 |
5 | 13 | 1918.32 | 20 | 14.54 | 2810 | 817 | 3.78 / 710.26 | 6 | 57 |
6 | 13 | 1722.52 | 20 | 14.50 | 2549 | 739 | 4.52 / 711.00 | 6 | 60 |
7 | 13 | 1196.12 | 20 | 14.56 | 1889 | 550 | 5.07 / 711.55 | 6 | 69 |
8 | 13 | 542.84 | 20 | 14.73 | 1057 | 311 | 5.38 / 711.86 | 6 | 80 |
9 | 8 | -6.88 | 385 | 14.82 | 316 | 1803 | 7.19 / 713.66 | 6 | 131 |
Average= | 25.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 63 | 14.74 | 479 | 445 | 0.44 / 699.64 | 6 | 66 |
2 | 7 | 2014.96 | 40 | 14.66 | 2883 | 1691 | 2.14 / 701.33 | 6 | 51 |
3 | 13 | 2017.68 | 20 | 14.59 | 2944 | 859 | 2.99 / 702.18 | 6 | 56 |
4 | 13 | 1957.52 | 20 | 14.53 | 2882 | 838 | 3.83 / 703.02 | 6 | 57 |
5 | 13 | 1661.32 | 20 | 14.50 | 2488 | 722 | 4.55 / 703.74 | 6 | 61 |
6 | 13 | 1356.52 | 20 | 14.51 | 2098 | 609 | 5.16 / 704.35 | 6 | 67 |
7 | 13 | 577.12 | 20 | 14.72 | 1106 | 326 | 5.49 / 704.68 | 6 | 81 |
8 | 8 | -4.00 | 387 | 14.82 | 314 | 1801 | 7.29 / 706.48 | 6 | 129 |
Average= | 26.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 62 | 14.74 | 483 | 441 | 0.44 / 692.51 | 6 | 72 |
2 | 7 | 2024.44 | 40 | 14.65 | 2913 | 1707 | 2.15 / 694.22 | 6 | 53 |
3 | 13 | 2007.08 | 20 | 14.60 | 2913 | 851 | 3.00 / 695.07 | 6 | 55 |
4 | 13 | 1929.32 | 20 | 14.53 | 2844 | 826 | 3.83 / 695.90 | 6 | 59 |
5 | 13 | 1629.32 | 20 | 14.51 | 2452 | 712 | 4.54 / 696.61 | 6 | 61 |
6 | 13 | 1016.80 | 20 | 14.61 | 1669 | 488 | 5.02 / 697.09 | 6 | 72 |
7 | 13 | 588.80 | 20 | 14.71 | 1120 | 330 | 5.35 / 697.42 | 6 | 81 |
8 | 8 | -3.56 | 376 | 14.82 | 317 | 1766 | 7.12 / 699.19 | 6 | 129 |
Average= | 26.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 60 | 14.74 | 475 | 420 | 0.42 / 685.21 | 6 | 68 |
2 | 10 | 1011.60 | 3 | 14.79 | 1694 | 75 | 0.50 / 685.29 | 6 | 48 |
3 | 7 | 2007.80 | 41 | 14.64 | 2907 | 1745 | 2.24 / 687.03 | 48 | 52 |
4 | 13 | 1992.20 | 20 | 14.60 | 2893 | 845 | 3.08 / 687.88 | 6 | 55 |
5 | 13 | 1923.08 | 20 | 14.53 | 2819 | 819 | 3.90 / 688.69 | 6 | 58 |
6 | 13 | 1728.40 | 20 | 14.49 | 2579 | 747 | 4.65 / 689.44 | 6 | 61 |
7 | 13 | 1188.40 | 20 | 14.56 | 1872 | 545 | 5.20 / 689.99 | 6 | 69 |
8 | 13 | 533.56 | 20 | 14.73 | 1054 | 311 | 5.51 / 690.30 | 6 | 82 |
9 | 8 | -6.60 | 376 | 14.82 | 318 | 1772 | 7.28 / 692.07 | 6 | 137 |
Average= | 27.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 62 | 14.73 | 492 | 449 | 0.45 / 678.05 | 6 | 66 |
2 | 3 | 962.84 | -1 | 15.27 | 3 | 0 | 0.00 / 678.05 | 6 | 66 |
3 | 7 | 2009.76 | 40 | 14.65 | 2903 | 1701 | 2.15 / 679.75 | 66 | 51 |
4 | 13 | 1987.68 | 20 | 14.61 | 2884 | 843 | 2.99 / 680.59 | 6 | 57 |
5 | 13 | 1912.96 | 20 | 14.54 | 2823 | 821 | 3.81 / 681.41 | 6 | 58 |
6 | 13 | 1717.32 | 20 | 14.49 | 2575 | 746 | 4.56 / 682.16 | 6 | 62 |
7 | 13 | 1184.20 | 20 | 14.56 | 1875 | 546 | 5.11 / 682.70 | 6 | 69 |
8 | 13 | 532.88 | 20 | 14.74 | 1046 | 308 | 5.41 / 683.01 | 6 | 81 |
9 | 8 | -6.76 | 381 | 14.82 | 315 | 1779 | 7.19 / 684.79 | 6 | 136 |
Average= | 28.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 59 | 14.76 | 466 | 406 | 0.41 / 670.62 | 6 | 60 |
2 | 10 | 1021.04 | 3 | 14.80 | 1692 | 75 | 0.48 / 670.70 | 6 | 49 |
3 | 7 | 2007.68 | 40 | 14.66 | 2879 | 1688 | 2.17 / 672.39 | 6 | 51 |
4 | 13 | 1991.52 | 20 | 14.61 | 2893 | 845 | 3.01 / 673.23 | 5 | 56 |
5 | 13 | 1918.56 | 20 | 14.54 | 2789 | 811 | 3.83 / 674.04 | 6 | 56 |
6 | 13 | 1723.64 | 20 | 14.51 | 2558 | 742 | 4.57 / 674.78 | 6 | 62 |
7 | 13 | 1205.08 | 20 | 14.57 | 1881 | 548 | 5.12 / 675.33 | 6 | 68 |
8 | 13 | 436.32 | 20 | 14.77 | 913 | 270 | 5.39 / 675.60 | 6 | 78 |
9 | 13 | 24.16 | 20 | 14.90 | 374 | 111 | 5.50 / 675.71 | 6 | 68 |
10 | 8 | -7.04 | 400 | 14.81 | 318 | 1884 | 7.38 / 677.60 | 6 | 94 |
Average= | 29.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 61 | 14.76 | 468 | 421 | 0.42 / 663.43 | 6 | 66 |
2 | 3 | 920.20 | -1 | 15.28 | 3 | 0 | 0.00 / 663.43 | 6 | 66 |
3 | 7 | 2016.00 | 40 | 14.65 | 2887 | 1692 | 2.11 / 665.12 | 66 | 51 |
4 | 13 | 2007.44 | 20 | 14.61 | 2919 | 853 | 2.97 / 665.97 | 6 | 55 |
5 | 13 | 1942.28 | 20 | 14.54 | 2839 | 826 | 3.79 / 666.80 | 6 | 56 |
6 | 13 | 1847.72 | 20 | 14.47 | 2723 | 788 | 4.58 / 667.58 | 6 | 61 |
7 | 13 | 1185.80 | 20 | 14.57 | 1864 | 543 | 5.12 / 668.13 | 6 | 67 |
8 | 13 | 563.52 | 20 | 14.73 | 1085 | 320 | 5.44 / 668.45 | 6 | 80 |
9 | 8 | -6.80 | 385 | 14.83 | 310 | 1770 | 7.21 / 670.22 | 6 | 137 |
Average= | 30.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 61 | 14.75 | 475 | 427 | 0.43 / 656.12 | 6 | 62 |
2 | 7 | 2007.48 | 40 | 14.66 | 2864 | 1679 | 2.11 / 657.80 | 62 | 47 |
3 | 13 | 1993.64 | 20 | 14.62 | 2870 | 839 | 2.95 / 658.63 | 6 | 53 |
4 | 13 | 1924.16 | 20 | 14.55 | 2799 | 815 | 3.76 / 659.45 | 6 | 58 |
5 | 13 | 1733.92 | 20 | 14.50 | 2577 | 747 | 4.51 / 660.20 | 6 | 60 |
6 | 13 | 1314.88 | 20 | 14.53 | 2039 | 593 | 5.10 / 660.79 | 6 | 66 |
7 | 13 | 647.24 | 20 | 14.71 | 1188 | 350 | 5.45 / 661.14 | 6 | 78 |
8 | 13 | 43.60 | 20 | 14.90 | 392 | 117 | 5.57 / 661.26 | 6 | 69 |
9 | 8 | -6.52 | 377 | 14.82 | 313 | 1749 | 7.32 / 663.00 | 6 | 135 |
Average= | 31.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 59 | 14.77 | 451 | 393 | 0.39 / 648.70 | 6 | 57 |
2 | 3 | 1111.32 | 3 | 14.86 | 1831 | 82 | 0.47 / 648.79 | 6 | 45 |
3 | 7 | 2016.60 | 40 | 14.66 | 2853 | 1673 | 2.15 / 650.46 | 45 | 51 |
4 | 13 | 2005.84 | 20 | 14.60 | 2910 | 850 | 3.00 / 651.31 | 6 | 55 |
5 | 13 | 1941.52 | 20 | 14.53 | 2838 | 825 | 3.82 / 652.13 | 6 | 55 |
6 | 13 | 1847.12 | 20 | 14.48 | 2710 | 785 | 4.61 / 652.92 | 6 | 60 |
7 | 13 | 1296.84 | 20 | 14.54 | 2004 | 583 | 5.19 / 653.50 | 6 | 66 |
8 | 13 | 631.84 | 20 | 14.71 | 1161 | 342 | 5.53 / 653.84 | 6 | 79 |
9 | 8 | -3.04 | 398 | 14.82 | 313 | 1846 | 7.38 / 655.69 | 6 | 129 |
Average= | 32.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 58 | 14.77 | 469 | 402 | 0.40 / 641.52 | 6 | 60 |
2 | 7 | 2007.88 | 40 | 14.66 | 2860 | 1677 | 2.08 / 643.20 | 6 | 52 |
3 | 13 | 1995.20 | 20 | 14.61 | 2907 | 849 | 2.93 / 644.05 | 6 | 53 |
4 | 13 | 1926.60 | 20 | 14.55 | 2798 | 814 | 3.74 / 644.86 | 6 | 56 |
5 | 13 | 1833.32 | 20 | 14.49 | 2682 | 777 | 4.52 / 645.64 | 6 | 60 |
6 | 13 | 1180.80 | 20 | 14.58 | 1857 | 542 | 5.06 / 646.18 | 6 | 66 |
7 | 13 | 555.80 | 20 | 14.74 | 1066 | 314 | 5.38 / 646.50 | 6 | 78 |
8 | 13 | 58.28 | 20 | 14.91 | 406 | 121 | 5.50 / 646.62 | 6 | 72 |
9 | 8 | -6.72 | 372 | 14.83 | 307 | 1694 | 7.19 / 648.31 | 6 | 129 |
Average= | 34.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 59 | 14.83 | 466 | 408 | 0.41 / 634.40 | 6 | 63 |
2 | 7 | 2005.24 | 40 | 14.64 | 2882 | 1688 | 2.10 / 636.09 | 63 | 52 |
3 | 13 | 1987.32 | 20 | 14.59 | 2895 | 845 | 2.94 / 636.93 | 6 | 53 |
4 | 13 | 1917.32 | 20 | 14.53 | 2797 | 813 | 3.75 / 637.75 | 6 | 56 |
5 | 13 | 1824.56 | 20 | 14.47 | 2686 | 777 | 4.53 / 638.52 | 6 | 59 |
6 | 13 | 1176.12 | 20 | 14.58 | 1854 | 541 | 5.07 / 639.06 | 6 | 68 |
7 | 13 | 444.76 | 20 | 14.79 | 925 | 274 | 5.34 / 639.34 | 6 | 80 |
8 | 8 | -5.12 | 390 | 14.84 | 308 | 1783 | 7.13 / 641.12 | 6 | 134 |
Average= | 35.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 57 | 14.77 | 473 | 398 | 0.40 / 630.30 | 6 | 60 |
2 | 3 | 1100.20 | 2 | 14.89 | 1795 | 53 | 0.45 / 630.35 | 6 | 43 |
3 | 7 | 1301.72 | 40 | 14.92 | 1957 | 1168 | 1.62 / 631.52 | 43 | 68 |
4 | 13 | 991.00 | 20 | 14.93 | 1612 | 481 | 2.10 / 632.00 | 6 | 71 |
5 | 13 | 346.40 | 20 | 14.99 | 798 | 239 | 2.34 / 632.24 | 6 | 80 |
6 | 8 | -6.52 | 379 | 14.95 | 309 | 1751 | 4.09 / 633.99 | 6 | 131 |
Average= | 37.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 98 | 14.74 | 472 | 682 | 0.68 / 622.02 | 6 | 62 |
2 | 2 | 198.00 | 27 | 14.90 | 617 | 248 | 0.93 / 622.27 | 6 | 59 |
3 | 10 | 1059.32 | 9 | 14.76 | 1712 | 227 | 1.16 / 622.50 | 6 | 59 |
4 | 10 | 1137.80 | 7 | 14.75 | 1802 | 186 | 1.34 / 622.68 | 6 | 60 |
5 | 10 | 1197.16 | 5 | 14.73 | 1922 | 142 | 1.49 / 622.82 | 6 | 57 |
6 | 10 | 1239.04 | 4 | 14.71 | 2008 | 118 | 1.60 / 622.94 | 6 | 53 |
7 | 3 | 1316.72 | 8 | 14.74 | 2035 | 240 | 1.84 / 623.18 | 6 | 64 |
8 | 7 | 2013.80 | 40 | 14.66 | 2888 | 1694 | 3.54 / 624.87 | 64 | 50 |
9 | 13 | 1978.84 | 20 | 14.61 | 2877 | 841 | 4.38 / 625.71 | 6 | 54 |
10 | 13 | 1906.20 | 20 | 14.56 | 2767 | 806 | 5.18 / 626.52 | 6 | 57 |
11 | 13 | 1708.76 | 20 | 14.53 | 2521 | 733 | 5.92 / 627.25 | 6 | 60 |
12 | 13 | 948.36 | 20 | 14.65 | 1557 | 456 | 6.37 / 627.71 | 6 | 71 |
13 | 13 | 739.92 | 20 | 14.68 | 1289 | 378 | 6.75 / 628.09 | 6 | 75 |
14 | 13 | 37.04 | 20 | 14.91 | 382 | 114 | 6.86 / 628.20 | 6 | 70 |
15 | 8 | -6.48 | 376 | 14.83 | 305 | 1701 | 8.56 / 629.90 | 6 | 130 |
Average= | 39.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 57 | 14.81 | 363 | 306 | 0.31 / 613.28 | 6 | 6 |
2 | 10 | 1002.28 | 10 | 14.97 | 496 | 74 | 0.38 / 613.35 | 6 | 10 |
3 | 10 | 1096.68 | 9 | 14.77 | 1337 | 178 | 0.56 / 613.53 | 6 | 19 |
4 | 10 | 1176.16 | 7 | 14.88 | 573 | 60 | 0.62 / 613.59 | 6 | 49 |
5 | 10 | 1236.20 | 6 | 14.90 | 1352 | 121 | 0.74 / 613.71 | 6 | 35 |
6 | 10 | 1275.04 | 4 | 14.71 | 1599 | 94 | 0.83 / 613.80 | 6 | 20 |
7 | 3 | 1379.88 | 9 | 14.87 | 1490 | 199 | 1.03 / 614.00 | 6 | 43 |
8 | 7 | 2006.28 | 40 | 14.76 | 2512 | 1483 | 2.52 / 615.48 | 43 | 22 |
9 | 13 | 2034.68 | 20 | 14.77 | 2353 | 695 | 3.21 / 616.18 | 6 | 27 |
10 | 13 | 1986.36 | 20 | 14.61 | 2740 | 801 | 4.01 / 616.98 | 6 | 51 |
11 | 13 | 1907.72 | 20 | 14.55 | 2557 | 744 | 4.76 / 617.72 | 6 | 35 |
12 | 13 | 1718.84 | 20 | 14.53 | 2392 | 695 | 5.45 / 618.42 | 6 | 45 |
13 | 13 | 1519.52 | 20 | 14.50 | 2154 | 625 | 6.08 / 619.04 | 6 | 43 |
14 | 13 | 642.12 | 20 | 14.75 | 1030 | 304 | 6.38 / 619.35 | 6 | 51 |
15 | 13 | 217.00 | 20 | 14.86 | 566 | 168 | 6.55 / 619.52 | 6 | 55 |
16 | 8 | -6.92 | 400 | 14.83 | 307 | 1821 | 8.37 / 621.34 | 6 | 101 |
Average= | 41.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 57 | 14.78 | 476 | 401 | 0.40 / 606.03 | 6 | 60 |
2 | 3 | 1026.24 | 1 | 14.95 | 1795 | 27 | 0.43 / 606.06 | 6 | 6 |
3 | 7 | 2009.92 | 40 | 14.66 | 2906 | 1704 | 2.13 / 607.76 | 6 | 51 |
4 | 13 | 1997.88 | 20 | 14.61 | 2918 | 853 | 2.98 / 608.61 | 6 | 53 |
5 | 13 | 1927.12 | 20 | 14.55 | 2834 | 825 | 3.81 / 609.44 | 6 | 58 |
6 | 13 | 1726.48 | 20 | 14.51 | 2571 | 746 | 4.56 / 610.18 | 6 | 62 |
7 | 13 | 1191.32 | 20 | 14.58 | 1870 | 545 | 5.10 / 610.73 | 6 | 69 |
8 | 13 | 574.32 | 20 | 14.74 | 1097 | 323 | 5.42 / 611.05 | 6 | 77 |
9 | 13 | 32.28 | 20 | 14.91 | 377 | 112 | 5.54 / 611.17 | 6 | 72 |
10 | 8 | -6.80 | 400 | 14.83 | 304 | 1803 | 7.34 / 612.97 | 6 | 55 |
Average= | 43.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 56 | 14.78 | 488 | 404 | 0.40 / 598.88 | 6 | 58 |
2 | 3 | 1023.92 | 1 | 14.95 | 1767 | 26 | 0.43 / 598.91 | 6 | 6 |
3 | 7 | 2005.00 | 40 | 14.67 | 2878 | 1689 | 2.12 / 600.59 | 6 | 52 |
4 | 13 | 1980.40 | 20 | 14.61 | 2900 | 847 | 2.97 / 601.44 | 5 | 54 |
5 | 13 | 1909.88 | 20 | 14.56 | 2806 | 817 | 3.78 / 602.26 | 6 | 56 |
6 | 13 | 1825.76 | 20 | 14.50 | 2678 | 777 | 4.56 / 603.04 | 6 | 59 |
7 | 13 | 1088.92 | 20 | 14.61 | 1752 | 512 | 5.07 / 603.55 | 6 | 68 |
8 | 13 | 563.92 | 20 | 14.74 | 1092 | 322 | 5.39 / 603.87 | 6 | 80 |
9 | 13 | 32.84 | 20 | 14.92 | 380 | 113 | 5.51 / 603.98 | 6 | 71 |
10 | 8 | -6.08 | 359 | 14.84 | 309 | 1646 | 7.15 / 605.63 | 6 | 130 |
Average= | 46.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 56 | 14.78 | 461 | 382 | 0.38 / 591.75 | 6 | 58 |
2 | 7 | 2005.96 | 40 | 14.67 | 2860 | 1678 | 2.06 / 593.42 | 58 | 53 |
3 | 13 | 1995.36 | 20 | 14.62 | 2897 | 847 | 2.91 / 594.27 | 6 | 54 |
4 | 13 | 1929.96 | 20 | 14.55 | 2824 | 822 | 3.73 / 595.09 | 6 | 57 |
5 | 13 | 1835.24 | 20 | 14.50 | 2696 | 782 | 4.51 / 595.88 | 6 | 57 |
6 | 13 | 1174.64 | 20 | 14.59 | 1842 | 537 | 5.05 / 596.41 | 6 | 68 |
7 | 13 | 528.80 | 20 | 14.76 | 1033 | 305 | 5.35 / 596.72 | 6 | 79 |
8 | 13 | 51.56 | 20 | 14.91 | 406 | 121 | 5.47 / 596.84 | 6 | 72 |
9 | 8 | -6.64 | 357 | 14.84 | 309 | 1637 | 7.11 / 598.48 | 6 | 134 |
Average= | 49.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 56 | 14.79 | 471 | 390 | 0.39 / 584.67 | 6 | 51 |
2 | 7 | 2023.88 | 40 | 14.67 | 2882 | 1691 | 2.08 / 586.36 | 51 | 50 |
3 | 13 | 2004.12 | 20 | 14.62 | 2892 | 846 | 2.93 / 587.20 | 6 | 55 |
4 | 13 | 1927.88 | 20 | 14.55 | 2807 | 817 | 3.74 / 588.02 | 6 | 58 |
5 | 13 | 1628.92 | 20 | 14.53 | 2447 | 711 | 4.45 / 588.73 | 6 | 61 |
6 | 13 | 1203.36 | 20 | 14.58 | 1878 | 548 | 5.00 / 589.28 | 6 | 69 |
7 | 13 | 454.40 | 20 | 14.78 | 939 | 278 | 5.28 / 589.56 | 6 | 80 |
8 | 13 | 33.84 | 20 | 14.92 | 382 | 114 | 5.39 / 589.67 | 6 | 71 |
9 | 8 | -4.52 | 372 | 14.84 | 307 | 1695 | 7.09 / 591.36 | 6 | 132 |
Average= | 53.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 108 | 14.77 | 445 | 710 | 0.71 / 576.37 | 6 | 51 |
2 | 2 | 192.84 | 27 | 14.88 | 588 | 236 | 0.95 / 576.61 | 6 | 49 |
3 | 10 | 1028.08 | 9 | 14.79 | 1639 | 218 | 1.16 / 576.82 | 6 | 53 |
4 | 10 | 1107.00 | 7 | 14.76 | 1775 | 183 | 1.35 / 577.01 | 6 | 55 |
5 | 10 | 1167.96 | 6 | 14.74 | 1903 | 168 | 1.52 / 577.18 | 6 | 55 |
6 | 10 | 1211.72 | 4 | 14.73 | 1955 | 115 | 1.63 / 577.29 | 6 | 50 |
7 | 3 | 1269.24 | 7 | 14.78 | 1991 | 206 | 1.84 / 577.50 | 6 | 62 |
8 | 7 | 2025.76 | 40 | 14.67 | 2871 | 1685 | 3.52 / 579.18 | 62 | 50 |
9 | 13 | 2007.40 | 20 | 14.62 | 2910 | 851 | 4.37 / 580.03 | 6 | 52 |
10 | 13 | 1939.96 | 20 | 14.55 | 2818 | 820 | 5.19 / 580.85 | 6 | 57 |
11 | 13 | 1850.80 | 20 | 14.50 | 2680 | 777 | 5.97 / 581.63 | 6 | 57 |
12 | 13 | 1199.28 | 20 | 14.59 | 1867 | 545 | 6.51 / 582.17 | 6 | 68 |
13 | 13 | 563.84 | 20 | 14.75 | 1062 | 313 | 6.83 / 582.49 | 6 | 73 |
14 | 13 | 60.72 | 20 | 14.91 | 409 | 122 | 6.95 / 582.61 | 6 | 70 |
15 | 13 | 17.16 | 20 | 14.91 | 360 | 107 | 7.06 / 582.72 | 6 | 66 |
16 | 8 | -4.44 | 340 | 14.84 | 309 | 1559 | 8.62 / 584.28 | 6 | 133 |
Average= | 58.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.00 | 55 | 14.82 | 376 | 306 | 0.31 / 567.06 | 6 | 6 |
2 | 10 | 1012.48 | 10 | 14.97 | 834 | 125 | 0.43 / 567.18 | 6 | 11 |
3 | 10 | 1112.72 | 9 | 15.00 | 423 | 57 | 0.49 / 567.24 | 6 | 15 |
4 | 10 | 1199.92 | 8 | 14.81 | 1125 | 133 | 0.62 / 567.37 | 6 | 9 |
5 | 10 | 1273.48 | 7 | 15.00 | 566 | 59 | 0.68 / 567.43 | 6 | 16 |
6 | 10 | 1333.56 | 6 | 14.92 | 687 | 62 | 0.74 / 567.49 | 6 | 39 |
7 | 10 | 1381.08 | 4 | 14.67 | 2035 | 119 | 0.86 / 567.61 | 6 | 41 |
8 | 10 | 1411.48 | 3 | 14.65 | 2206 | 97 | 0.96 / 567.71 | 6 | 28 |
9 | 3 | 1409.20 | 10 | 15.03 | 927 | 139 | 1.10 / 567.85 | 6 | 22 |
10 | 7 | 2006.68 | 40 | 14.99 | 1799 | 1079 | 2.18 / 568.93 | 22 | 14 |
11 | 13 | 2077.80 | 20 | 14.86 | 2143 | 637 | 2.81 / 569.57 | 6 | 39 |
12 | 13 | 2115.80 | 20 | 14.67 | 2568 | 753 | 3.57 / 570.32 | 6 | 25 |
13 | 13 | 2074.44 | 20 | 14.78 | 1825 | 539 | 4.11 / 570.86 | 6 | 33 |
14 | 13 | 2011.36 | 20 | 14.66 | 2067 | 606 | 4.71 / 571.46 | 6 | 8 |
15 | 13 | 1932.32 | 20 | 14.63 | 2074 | 607 | 5.32 / 572.07 | 6 | 64 |
16 | 13 | 1837.24 | 20 | 14.50 | 2179 | 632 | 5.95 / 572.70 | 6 | 29 |
17 | 13 | 1432.40 | 20 | 14.61 | 1536 | 449 | 6.40 / 573.15 | 6 | 23 |
18 | 13 | 1023.60 | 20 | 14.73 | 1069 | 315 | 6.72 / 573.47 | 6 | 11 |
19 | 13 | 728.04 | 20 | 14.77 | 862 | 255 | 6.97 / 573.72 | 6 | 14 |
20 | 13 | 539.08 | 20 | 14.78 | 826 | 244 | 7.21 / 573.97 | 6 | 39 |
21 | 13 | 225.68 | 20 | 14.85 | 529 | 157 | 7.37 / 574.12 | 6 | 37 |
22 | 13 | 26.72 | 20 | 14.90 | 348 | 104 | 7.48 / 574.23 | 6 | 34 |
23 | 8 | -6.60 | 320 | 14.83 | 302 | 1433 | 8.91 / 575.66 | 6 | 62 |
Average= | 63.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 56 | 14.80 | 495 | 410 | 0.41 / 559.83 | 6 | 47 |
2 | 7 | 2010.72 | 40 | 14.67 | 2888 | 1695 | 2.10 / 561.52 | 47 | 51 |
3 | 13 | 1987.88 | 20 | 14.63 | 2885 | 844 | 2.95 / 562.37 | 6 | 55 |
4 | 13 | 1915.76 | 20 | 14.55 | 2804 | 816 | 3.77 / 563.18 | 6 | 58 |
5 | 13 | 1820.16 | 20 | 14.51 | 2686 | 779 | 4.54 / 563.96 | 6 | 59 |
6 | 13 | 1187.68 | 20 | 14.59 | 1874 | 547 | 5.09 / 564.51 | 6 | 68 |
7 | 13 | 564.92 | 20 | 14.76 | 1074 | 317 | 5.41 / 564.83 | 6 | 79 |
8 | 13 | 31.80 | 20 | 14.92 | 381 | 114 | 5.52 / 564.94 | 6 | 70 |
9 | 8 | -6.72 | 400 | 14.84 | 305 | 1810 | 7.33 / 566.75 | 6 | 83 |
Average= | 70.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 57 | 14.79 | 485 | 409 | 0.41 / 552.83 | 6 | 51 |
2 | 3 | 953.00 | -1 | 15.31 | 3 | 0 | 0.00 / 552.83 | 6 | 51 |
3 | 7 | 2010.08 | 40 | 14.66 | 2890 | 1695 | 2.10 / 554.53 | 51 | 52 |
4 | 13 | 1992.56 | 20 | 14.62 | 2890 | 845 | 2.95 / 555.37 | 6 | 56 |
5 | 13 | 1920.92 | 20 | 14.55 | 2797 | 814 | 3.76 / 556.19 | 6 | 57 |
6 | 13 | 1624.52 | 20 | 14.54 | 2398 | 697 | 4.46 / 556.88 | 6 | 60 |
7 | 13 | 1100.96 | 20 | 14.61 | 1758 | 514 | 4.97 / 557.40 | 6 | 70 |
8 | 13 | 551.92 | 20 | 14.76 | 1066 | 315 | 5.29 / 557.71 | 6 | 78 |
9 | 13 | 51.92 | 20 | 14.91 | 401 | 120 | 5.41 / 557.83 | 6 | 69 |
10 | 8 | -6.60 | 349 | 14.85 | 306 | 1586 | 6.99 / 559.42 | 6 | 134 |
Average= | 79.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 110 | 14.76 | 467 | 758 | 0.76 / 544.44 | 6 | 56 |
2 | 2 | 180.96 | 27 | 14.89 | 541 | 217 | 0.98 / 544.66 | 6 | 40 |
3 | 10 | 1042.92 | 9 | 14.77 | 1677 | 223 | 1.20 / 544.88 | 6 | 57 |
4 | 10 | 1122.60 | 7 | 14.75 | 1768 | 183 | 1.38 / 545.06 | 6 | 56 |
5 | 10 | 1184.28 | 6 | 14.72 | 1908 | 169 | 1.55 / 545.23 | 6 | 56 |
6 | 10 | 1224.96 | 4 | 14.73 | 1936 | 114 | 1.66 / 545.34 | 6 | 48 |
7 | 3 | 1305.88 | 8 | 14.77 | 2006 | 237 | 1.90 / 545.58 | 6 | 63 |
8 | 7 | 2026.60 | 40 | 14.68 | 2861 | 1680 | 3.58 / 547.26 | 63 | 49 |
9 | 13 | 2003.60 | 20 | 14.64 | 2868 | 840 | 4.42 / 548.10 | 6 | 52 |
10 | 13 | 1932.12 | 20 | 14.56 | 2789 | 812 | 5.23 / 548.91 | 6 | 57 |
11 | 13 | 1836.76 | 20 | 14.51 | 2693 | 782 | 6.01 / 549.70 | 6 | 60 |
12 | 13 | 979.12 | 20 | 14.66 | 1592 | 467 | 6.48 / 550.16 | 6 | 68 |
13 | 13 | 573.60 | 20 | 14.77 | 1051 | 310 | 6.79 / 550.47 | 6 | 71 |
14 | 13 | 63.76 | 20 | 14.92 | 412 | 123 | 6.91 / 550.60 | 6 | 69 |
15 | 8 | -4.40 | 400 | 14.85 | 308 | 1830 | 8.74 / 552.43 | 6 | 128 |
Average= | 92.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 59 | 14.82 | 400 | 350 | 0.35 / 534.64 | 6 | 6 |
2 | 10 | 1046.72 | 9 | 14.83 | 1202 | 160 | 0.51 / 534.80 | 6 | 6 |
3 | 10 | 1135.40 | 8 | 14.99 | 428 | 51 | 0.56 / 534.85 | 6 | 6 |
4 | 10 | 1220.48 | 8 | 14.92 | 1002 | 120 | 0.68 / 534.97 | 6 | 49 |
5 | 10 | 1292.08 | 7 | 14.93 | 638 | 67 | 0.75 / 535.03 | 6 | 21 |
6 | 10 | 1349.92 | 5 | 14.80 | 1166 | 86 | 0.83 / 535.12 | 6 | 57 |
7 | 10 | 1391.64 | 4 | 14.68 | 2121 | 125 | 0.96 / 535.25 | 6 | 37 |
8 | 3 | 1488.84 | 12 | 15.09 | 600 | 109 | 1.07 / 535.35 | 6 | 11 |
9 | 5 | 1326.56 | 8 | 15.13 | 591 | 72 | 1.14 / 535.43 | 6 | 29 |
10 | 7 | 2023.92 | 40 | 14.92 | 1937 | 1156 | 2.29 / 536.58 | 29 | 6 |
11 | 13 | 2098.68 | 20 | 15.02 | 1446 | 434 | 2.73 / 537.02 | 6 | 6 |
12 | 13 | 2148.36 | 20 | 14.74 | 2411 | 711 | 3.44 / 537.73 | 6 | 46 |
13 | 13 | 2118.92 | 20 | 14.76 | 2072 | 612 | 4.05 / 538.34 | 6 | 24 |
14 | 13 | 2053.68 | 20 | 14.69 | 2027 | 596 | 4.65 / 538.93 | 6 | 13 |
15 | 13 | 1970.64 | 20 | 14.76 | 1458 | 430 | 5.08 / 539.36 | 6 | 13 |
16 | 13 | 1887.28 | 20 | 14.59 | 2014 | 588 | 5.67 / 539.95 | 6 | 15 |
17 | 13 | 1800.48 | 20 | 14.57 | 1879 | 548 | 6.21 / 540.50 | 6 | 42 |
18 | 13 | 1706.52 | 20 | 14.51 | 1918 | 557 | 6.77 / 541.06 | 6 | 21 |
19 | 13 | 1297.28 | 20 | 14.59 | 1498 | 437 | 7.21 / 541.49 | 6 | 10 |
20 | 13 | 886.20 | 20 | 14.71 | 1076 | 317 | 7.52 / 541.81 | 6 | 17 |
21 | 13 | 573.48 | 20 | 14.79 | 772 | 228 | 7.75 / 542.04 | 6 | 15 |
22 | 13 | 250.76 | 20 | 14.85 | 560 | 166 | 7.92 / 542.20 | 6 | 40 |
23 | 13 | 36.92 | 20 | 14.90 | 369 | 110 | 8.03 / 542.31 | 6 | 35 |
24 | 8 | -6.64 | 300 | 14.84 | 307 | 1367 | 9.39 / 543.68 | 6 | 81 |
Average= | 108.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.64 | 57 | 14.81 | 468 | 395 | 0.40 / 527.41 | 6 | 39 |
2 | 3 | 1072.88 | 2 | 14.93 | 1788 | 53 | 0.45 / 527.46 | 6 | 28 |
3 | 7 | 2011.96 | 40 | 14.68 | 2841 | 1668 | 2.12 / 529.13 | 28 | 51 |
4 | 13 | 2004.72 | 20 | 14.62 | 2874 | 840 | 2.96 / 529.97 | 6 | 55 |
5 | 13 | 1935.52 | 20 | 14.57 | 2773 | 808 | 3.77 / 530.78 | 6 | 54 |
6 | 13 | 1738.24 | 20 | 14.53 | 2557 | 743 | 4.51 / 531.52 | 6 | 60 |
7 | 13 | 1189.96 | 20 | 14.60 | 1858 | 543 | 5.05 / 532.07 | 6 | 67 |
8 | 13 | 443.96 | 20 | 14.82 | 889 | 263 | 5.31 / 532.33 | 6 | 72 |
9 | 13 | 35.24 | 20 | 14.94 | 380 | 114 | 5.43 / 532.44 | 6 | 63 |
10 | 8 | -6.56 | 400 | 14.86 | 310 | 1843 | 7.27 / 534.29 | 6 | 91 |
Average= | 133.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 57 | 14.81 | 480 | 405 | 0.41 / 520.33 | 6 | 49 |
2 | 7 | 2008.80 | 40 | 14.67 | 2877 | 1688 | 2.09 / 522.02 | 49 | 49 |
3 | 13 | 1987.28 | 20 | 14.63 | 2905 | 850 | 2.94 / 522.87 | 6 | 54 |
4 | 13 | 1922.00 | 20 | 14.57 | 2801 | 816 | 3.76 / 523.69 | 6 | 57 |
5 | 13 | 1626.84 | 20 | 14.55 | 2415 | 703 | 4.46 / 524.39 | 6 | 62 |
6 | 13 | 1191.80 | 20 | 14.60 | 1861 | 543 | 5.01 / 524.93 | 6 | 68 |
7 | 13 | 520.32 | 20 | 14.78 | 1011 | 299 | 5.30 / 525.23 | 6 | 74 |
8 | 13 | 22.36 | 20 | 14.94 | 360 | 108 | 5.41 / 525.34 | 6 | 71 |
9 | 8 | -6.52 | 370 | 14.86 | 305 | 1677 | 7.09 / 527.02 | 6 | 140 |
Average= | 175.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 57 | 14.80 | 470 | 396 | 0.40 / 513.30 | 6 | 49 |
2 | 7 | 2005.84 | 40 | 14.68 | 2865 | 1682 | 2.08 / 514.99 | 49 | 51 |
3 | 13 | 1968.32 | 20 | 14.62 | 2860 | 836 | 2.92 / 515.82 | 6 | 56 |
4 | 13 | 1885.48 | 20 | 14.57 | 2751 | 802 | 3.72 / 516.62 | 6 | 56 |
5 | 13 | 1695.04 | 20 | 14.54 | 2506 | 729 | 4.45 / 517.35 | 6 | 61 |
6 | 13 | 1075.20 | 20 | 14.64 | 1718 | 503 | 4.95 / 517.86 | 6 | 68 |
7 | 13 | 430.16 | 20 | 14.81 | 895 | 265 | 5.21 / 518.12 | 6 | 75 |
8 | 13 | 24.96 | 20 | 14.94 | 368 | 110 | 5.32 / 518.23 | 6 | 71 |
9 | 8 | -6.60 | 366 | 14.86 | 312 | 1697 | 7.02 / 519.93 | 6 | 134 |
Average= | 259.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 87 | 14.78 | 467 | 600 | 0.60 / 506.13 | 6 | 52 |
2 | 3 | 83.32 | -14 | 15.33 | 3 | 0 | 0.00 / 506.13 | 6 | 52 |
3 | 7 | 2026.68 | 40 | 14.68 | 2900 | 1703 | 2.30 / 507.83 | 52 | 51 |
4 | 13 | 2003.20 | 20 | 14.63 | 2906 | 850 | 3.15 / 508.68 | 6 | 53 |
5 | 13 | 1929.44 | 20 | 14.57 | 2815 | 820 | 3.97 / 509.50 | 6 | 55 |
6 | 13 | 1835.92 | 20 | 14.52 | 2679 | 778 | 4.75 / 510.28 | 6 | 58 |
7 | 13 | 1098.08 | 20 | 14.62 | 1752 | 512 | 5.26 / 510.79 | 6 | 68 |
8 | 13 | 676.52 | 20 | 14.72 | 1217 | 358 | 5.62 / 511.15 | 6 | 75 |
9 | 13 | 26.60 | 20 | 14.93 | 364 | 109 | 5.73 / 511.26 | 6 | 72 |
10 | 8 | -6.64 | 361 | 14.85 | 307 | 1646 | 7.38 / 512.91 | 6 | 130 |
Average= | 512.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 57 | 14.81 | 439 | 371 | 0.37 / 498.68 | 6 | 40 |
2 | 10 | 1045.68 | 6 | 14.80 | 1666 | 148 | 0.52 / 498.83 | 6 | 56 |
3 | 10 | 1096.48 | 5 | 14.78 | 1788 | 132 | 0.65 / 498.96 | 6 | 52 |
4 | 10 | 1128.64 | 3 | 14.77 | 1848 | 82 | 0.73 / 499.04 | 6 | 42 |
5 | 3 | 1148.16 | 4 | 14.86 | 1862 | 111 | 0.84 / 499.15 | 6 | 52 |
6 | 7 | 2010.64 | 40 | 14.69 | 2847 | 1673 | 2.52 / 500.83 | 52 | 53 |
7 | 13 | 1956.64 | 20 | 14.65 | 2818 | 826 | 3.34 / 501.65 | 6 | 56 |
8 | 13 | 1870.84 | 20 | 14.59 | 2736 | 798 | 4.14 / 502.45 | 6 | 61 |
9 | 13 | 1556.12 | 20 | 14.58 | 2307 | 673 | 4.81 / 503.12 | 6 | 65 |
10 | 13 | 766.52 | 20 | 14.75 | 1294 | 382 | 5.19 / 503.50 | 6 | 69 |
11 | 13 | 121.44 | 20 | 14.93 | 487 | 145 | 5.34 / 503.65 | 6 | 66 |
12 | 8 | -6.40 | 400 | 14.87 | 316 | 1880 | 7.22 / 505.53 | 6 | 99 |
Average= | 6.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 70 | 14.80 | 459 | 476 | 0.48 / 491.63 | 6 | 55 |
2 | 3 | 586.04 | -6 | 15.32 | 3 | 0 | 0.00 / 491.63 | 6 | 55 |
3 | 7 | 2010.52 | 41 | 14.67 | 2889 | 1738 | 2.21 / 493.37 | 55 | 51 |
4 | 13 | 1980.20 | 20 | 14.64 | 2853 | 835 | 3.05 / 494.20 | 6 | 57 |
5 | 13 | 1905.68 | 20 | 14.58 | 2763 | 806 | 3.85 / 495.01 | 6 | 57 |
6 | 13 | 1602.56 | 20 | 14.56 | 2395 | 697 | 4.55 / 495.71 | 6 | 64 |
7 | 13 | 968.56 | 20 | 14.67 | 1582 | 464 | 5.02 / 496.17 | 6 | 72 |
8 | 13 | 412.76 | 20 | 14.82 | 882 | 261 | 5.28 / 496.43 | 6 | 77 |
9 | 8 | -2.88 | 400 | 14.86 | 316 | 1878 | 7.16 / 498.31 | 6 | 97 |
Average= | 6.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.20 | 65 | 14.82 | 444 | 428 | 0.43 / 484.25 | 6 | 42 |
2 | 10 | 1039.52 | 3 | 14.85 | 1692 | 75 | 0.50 / 484.32 | 6 | 44 |
3 | 3 | 1110.24 | 3 | 14.91 | 1821 | 81 | 0.58 / 484.40 | 6 | 42 |
4 | 7 | 2007.52 | 41 | 14.69 | 2841 | 1711 | 2.30 / 486.11 | 42 | 52 |
5 | 13 | 1990.64 | 20 | 14.64 | 2855 | 836 | 3.13 / 486.95 | 6 | 55 |
6 | 13 | 1909.92 | 20 | 14.57 | 2794 | 814 | 3.95 / 487.76 | 6 | 59 |
7 | 13 | 1509.04 | 20 | 14.59 | 2243 | 655 | 4.60 / 488.42 | 6 | 63 |
8 | 13 | 1310.28 | 20 | 14.59 | 1959 | 572 | 5.17 / 488.99 | 6 | 65 |
9 | 13 | 557.44 | 20 | 14.78 | 1030 | 304 | 5.48 / 489.30 | 6 | 71 |
10 | 13 | 54.84 | 20 | 14.94 | 403 | 120 | 5.60 / 489.42 | 6 | 67 |
11 | 8 | -6.52 | 376 | 14.87 | 311 | 1739 | 7.34 / 491.15 | 6 | 129 |
Average= | 6.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 60 | 14.82 | 454 | 404 | 0.40 / 477.05 | 6 | 46 |
2 | 10 | 1046.00 | 4 | 14.84 | 1727 | 103 | 0.51 / 477.15 | 6 | 52 |
3 | 3 | 1077.96 | 2 | 14.92 | 1771 | 53 | 0.56 / 477.20 | 6 | 33 |
4 | 7 | 2021.60 | 40 | 14.67 | 2889 | 1695 | 2.25 / 478.90 | 33 | 53 |
5 | 13 | 2007.76 | 20 | 14.63 | 2915 | 853 | 3.11 / 479.75 | 6 | 54 |
6 | 13 | 1924.24 | 20 | 14.58 | 2805 | 818 | 3.93 / 480.57 | 6 | 57 |
7 | 13 | 1528.84 | 20 | 14.57 | 2315 | 675 | 4.60 / 481.24 | 6 | 63 |
8 | 13 | 1031.68 | 20 | 14.65 | 1675 | 491 | 5.09 / 481.73 | 6 | 72 |
9 | 13 | 395.32 | 20 | 14.84 | 848 | 252 | 5.34 / 481.98 | 6 | 75 |
10 | 8 | -6.44 | 394 | 14.88 | 313 | 1835 | 7.18 / 483.82 | 6 | 134 |
Average= | 6.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 60 | 14.82 | 473 | 421 | 0.42 / 469.77 | 6 | 59 |
2 | 7 | 2020.12 | 40 | 14.68 | 2910 | 1709 | 2.13 / 471.48 | 59 | 53 |
3 | 13 | 1992.44 | 20 | 14.63 | 2890 | 846 | 2.97 / 472.33 | 6 | 55 |
4 | 13 | 1923.60 | 20 | 14.57 | 2822 | 822 | 3.80 / 473.15 | 6 | 58 |
5 | 13 | 1829.24 | 20 | 14.51 | 2723 | 790 | 4.59 / 473.94 | 6 | 61 |
6 | 13 | 1074.48 | 20 | 14.66 | 1727 | 506 | 5.09 / 474.44 | 6 | 71 |
7 | 13 | 561.48 | 20 | 14.79 | 1081 | 320 | 5.41 / 474.76 | 6 | 80 |
8 | 8 | -6.68 | 398 | 14.88 | 317 | 1877 | 7.29 / 476.64 | 6 | 132 |
Average= | 6.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 59 | 14.81 | 478 | 418 | 0.42 / 464.33 | 6 | 60 |
2 | 3 | 1018.44 | 1 | 15.00 | 1745 | 26 | 0.44 / 464.35 | 5 | 6 |
3 | 7 | 1621.60 | 40 | 14.82 | 2407 | 1427 | 1.87 / 465.78 | 6 | 62 |
4 | 13 | 1542.88 | 20 | 14.80 | 2325 | 688 | 2.56 / 466.47 | 6 | 64 |
5 | 13 | 1338.24 | 20 | 14.78 | 2063 | 610 | 3.17 / 467.08 | 6 | 67 |
6 | 13 | 710.04 | 20 | 14.83 | 1268 | 376 | 3.54 / 467.46 | 6 | 78 |
7 | 13 | 90.76 | 20 | 14.97 | 456 | 137 | 3.68 / 467.59 | 6 | 72 |
8 | 8 | -5.52 | 370 | 14.90 | 319 | 1759 | 5.44 / 469.35 | 6 | 130 |
Average= | 6.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 59 | 14.80 | 494 | 431 | 0.43 / 457.27 | 6 | 64 |
2 | 7 | 2007.40 | 40 | 14.69 | 2907 | 1708 | 2.14 / 458.98 | 64 | 52 |
3 | 13 | 1987.40 | 20 | 14.65 | 2877 | 843 | 2.98 / 459.82 | 6 | 54 |
4 | 13 | 1909.92 | 20 | 14.58 | 2800 | 816 | 3.80 / 460.64 | 6 | 59 |
5 | 13 | 1503.96 | 20 | 14.59 | 2282 | 666 | 4.46 / 461.31 | 5 | 64 |
6 | 13 | 1182.64 | 20 | 14.61 | 1871 | 547 | 5.01 / 461.85 | 6 | 70 |
7 | 13 | 353.04 | 20 | 14.85 | 818 | 243 | 5.25 / 462.09 | 6 | 84 |
8 | 8 | -4.00 | 385 | 14.88 | 317 | 1816 | 7.07 / 463.91 | 6 | 133 |
Average= | 6.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 61 | 14.81 | 484 | 437 | 0.44 / 449.93 | 6 | 64 |
2 | 3 | 944.52 | -1 | 15.32 | 3 | 0 | 0.00 / 449.93 | 6 | 64 |
3 | 7 | 2011.08 | 40 | 14.69 | 2909 | 1709 | 2.15 / 451.63 | 64 | 53 |
4 | 13 | 1998.84 | 20 | 14.64 | 2931 | 858 | 3.00 / 452.49 | 6 | 54 |
5 | 13 | 1937.84 | 20 | 14.58 | 2824 | 823 | 3.83 / 453.32 | 6 | 57 |
6 | 13 | 1843.76 | 20 | 14.53 | 2704 | 786 | 4.61 / 454.10 | 6 | 61 |
7 | 13 | 1284.92 | 20 | 14.59 | 1996 | 582 | 5.20 / 454.68 | 6 | 68 |
8 | 13 | 521.20 | 20 | 14.80 | 1039 | 308 | 5.50 / 454.99 | 6 | 82 |
9 | 8 | -6.88 | 393 | 14.88 | 316 | 1848 | 7.35 / 456.84 | 6 | 140 |
Average= | 6.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 61 | 14.80 | 489 | 441 | 0.44 / 442.44 | 6 | 61 |
2 | 10 | 1003.60 | 3 | 14.86 | 1694 | 76 | 0.52 / 442.52 | 6 | 53 |
3 | 3 | 944.24 | -1 | 15.31 | 3 | 0 | 0.08 / 442.52 | 6 | 53 |
4 | 7 | 2009.12 | 41 | 14.69 | 2889 | 1740 | 2.26 / 444.26 | 53 | 53 |
5 | 13 | 1980.84 | 20 | 14.65 | 2877 | 843 | 3.10 / 445.10 | 6 | 54 |
6 | 13 | 1901.96 | 20 | 14.59 | 2803 | 818 | 3.92 / 445.92 | 6 | 59 |
7 | 13 | 1700.16 | 20 | 14.55 | 2535 | 738 | 4.66 / 446.65 | 6 | 61 |
8 | 13 | 1383.68 | 20 | 14.57 | 2120 | 618 | 5.27 / 447.27 | 6 | 67 |
9 | 13 | 600.40 | 20 | 14.78 | 1130 | 334 | 5.61 / 447.61 | 6 | 80 |
10 | 13 | 71.12 | 20 | 14.95 | 433 | 129 | 5.74 / 447.74 | 6 | 71 |
11 | 8 | -6.68 | 368 | 14.88 | 320 | 1752 | 7.49 / 449.49 | 6 | 133 |
Average= | 6.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 61 | 14.82 | 489 | 442 | 0.44 / 435.05 | 6 | 64 |
2 | 7 | 2024.80 | 41 | 14.69 | 2919 | 1758 | 2.20 / 436.81 | 64 | 51 |
3 | 13 | 1996.20 | 20 | 14.63 | 2934 | 858 | 3.06 / 437.67 | 5 | 55 |
4 | 13 | 1919.80 | 20 | 14.57 | 2830 | 825 | 3.88 / 438.49 | 5 | 57 |
5 | 13 | 1721.44 | 20 | 14.55 | 2554 | 743 | 4.63 / 439.23 | 6 | 61 |
6 | 13 | 1184.88 | 20 | 14.62 | 1877 | 549 | 5.18 / 439.78 | 6 | 70 |
7 | 13 | 629.64 | 20 | 14.76 | 1180 | 348 | 5.52 / 440.13 | 6 | 80 |
8 | 8 | -6.68 | 390 | 14.88 | 322 | 1869 | 7.39 / 442.00 | 6 | 133 |
Average= | 6.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 61 | 14.82 | 495 | 447 | 0.45 / 427.83 | 6 | 62 |
2 | 7 | 2007.08 | 40 | 14.69 | 2909 | 1709 | 2.16 / 429.54 | 62 | 55 |
3 | 13 | 1987.92 | 20 | 14.64 | 2916 | 854 | 3.01 / 430.39 | 5 | 54 |
4 | 13 | 1918.48 | 20 | 14.59 | 2818 | 822 | 3.83 / 431.22 | 5 | 58 |
5 | 13 | 1721.48 | 20 | 14.55 | 2568 | 747 | 4.58 / 431.96 | 6 | 62 |
6 | 13 | 968.32 | 20 | 14.69 | 1611 | 473 | 5.05 / 432.44 | 6 | 73 |
7 | 13 | 545.56 | 20 | 14.80 | 1064 | 315 | 5.37 / 432.75 | 6 | 80 |
8 | 13 | 109.84 | 20 | 14.94 | 483 | 144 | 5.51 / 432.90 | 6 | 75 |
9 | 8 | -6.76 | 357 | 14.88 | 322 | 1711 | 7.22 / 434.61 | 6 | 135 |
Average= | 6.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 65 | 14.81 | 477 | 459 | 0.46 / 420.41 | 6 | 63 |
2 | 3 | 685.52 | -5 | 15.33 | 3 | 0 | 0.00 / 420.41 | 6 | 63 |
3 | 5 | 1321.88 | 8 | 14.88 | 2065 | 246 | 0.71 / 420.66 | 6 | 65 |
4 | 7 | 2007.68 | 40 | 14.70 | 2891 | 1700 | 2.40 / 422.36 | 65 | 52 |
5 | 13 | 1985.40 | 20 | 14.66 | 2887 | 846 | 3.25 / 423.21 | 5 | 55 |
6 | 13 | 1913.24 | 20 | 14.58 | 2821 | 823 | 4.07 / 424.03 | 5 | 59 |
7 | 13 | 1613.08 | 20 | 14.57 | 2446 | 713 | 4.79 / 424.74 | 6 | 65 |
8 | 13 | 1191.88 | 20 | 14.63 | 1883 | 551 | 5.34 / 425.29 | 6 | 68 |
9 | 13 | 515.88 | 20 | 14.81 | 1025 | 304 | 5.64 / 425.60 | 6 | 80 |
10 | 8 | -6.56 | 374 | 14.89 | 321 | 1788 | 7.43 / 427.38 | 6 | 131 |
Average= | 6.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 59 | 14.82 | 480 | 420 | 0.42 / 413.15 | 6 | 49 |
2 | 10 | 1008.96 | 4 | 14.85 | 1674 | 99 | 0.52 / 413.25 | 6 | 52 |
3 | 10 | 1039.48 | 3 | 14.84 | 1738 | 77 | 0.60 / 413.32 | 6 | 44 |
4 | 3 | 1031.20 | 1 | 14.97 | 1768 | 26 | 0.62 / 413.35 | 6 | 8 |
5 | 7 | 2006.00 | 40 | 14.71 | 2842 | 1672 | 2.30 / 415.02 | 8 | 50 |
6 | 13 | 1975.80 | 20 | 14.66 | 2854 | 837 | 3.13 / 415.86 | 5 | 56 |
7 | 13 | 1900.76 | 20 | 14.61 | 2759 | 806 | 3.94 / 416.67 | 6 | 57 |
8 | 13 | 1501.00 | 20 | 14.60 | 2270 | 663 | 4.60 / 417.33 | 6 | 66 |
9 | 13 | 972.20 | 20 | 14.70 | 1567 | 461 | 5.06 / 417.79 | 6 | 69 |
10 | 13 | 416.88 | 20 | 14.85 | 854 | 254 | 5.32 / 418.04 | 6 | 71 |
11 | 8 | -5.52 | 400 | 14.89 | 321 | 1912 | 7.23 / 419.95 | 6 | 110 |
Average= | 6.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 59 | 14.83 | 478 | 418 | 0.42 / 405.82 | 6 | 56 |
2 | 7 | 2028.96 | 40 | 14.70 | 2918 | 1716 | 2.13 / 407.54 | 56 | 52 |
3 | 13 | 2015.84 | 20 | 14.66 | 2909 | 853 | 2.99 / 408.39 | 5 | 53 |
4 | 13 | 1946.80 | 20 | 14.58 | 2858 | 833 | 3.82 / 409.23 | 6 | 57 |
5 | 13 | 1542.36 | 20 | 14.59 | 2350 | 686 | 4.51 / 409.91 | 6 | 65 |
6 | 13 | 1223.24 | 20 | 14.62 | 1924 | 563 | 5.07 / 410.47 | 6 | 68 |
7 | 13 | 664.60 | 20 | 14.76 | 1196 | 353 | 5.42 / 410.83 | 6 | 73 |
8 | 8 | -6.72 | 400 | 14.89 | 319 | 1900 | 7.32 / 412.73 | 6 | 101 |
Average= | 6.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 57 | 14.83 | 481 | 407 | 0.41 / 398.68 | 6 | 60 |
2 | 3 | 1041.32 | 1 | 14.97 | 1749 | 26 | 0.43 / 398.71 | 6 | 13 |
3 | 7 | 2009.96 | 40 | 14.71 | 2896 | 1704 | 2.14 / 400.41 | 13 | 51 |
4 | 13 | 1989.36 | 20 | 14.66 | 2899 | 850 | 2.99 / 401.26 | 5 | 56 |
5 | 13 | 1910.60 | 20 | 14.60 | 2810 | 821 | 3.81 / 402.08 | 5 | 59 |
6 | 13 | 1501.20 | 20 | 14.62 | 2283 | 668 | 4.47 / 402.75 | 5 | 66 |
7 | 13 | 1296.80 | 20 | 14.61 | 2016 | 589 | 5.06 / 403.34 | 6 | 67 |
8 | 13 | 430.16 | 20 | 14.85 | 906 | 269 | 5.33 / 403.61 | 6 | 81 |
9 | 8 | -4.88 | 381 | 14.90 | 317 | 1800 | 7.13 / 405.41 | 6 | 137 |
Average= | 6.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 58 | 14.83 | 489 | 421 | 0.42 / 391.48 | 6 | 63 |
2 | 7 | 2008.20 | 40 | 14.71 | 2907 | 1710 | 2.13 / 393.19 | 63 | 55 |
3 | 13 | 1966.24 | 20 | 14.66 | 2887 | 846 | 2.98 / 394.04 | 5 | 56 |
4 | 13 | 1890.84 | 20 | 14.60 | 2797 | 817 | 3.79 / 394.85 | 6 | 60 |
5 | 13 | 1699.88 | 20 | 14.57 | 2546 | 742 | 4.54 / 395.59 | 5 | 64 |
6 | 13 | 1267.96 | 20 | 14.62 | 1994 | 583 | 5.12 / 396.18 | 6 | 69 |
7 | 13 | 470.44 | 20 | 14.84 | 978 | 290 | 5.41 / 396.47 | 6 | 82 |
8 | 13 | 16.64 | 20 | 14.98 | 373 | 112 | 5.52 / 396.58 | 6 | 69 |
9 | 8 | -6.52 | 353 | 14.90 | 322 | 1694 | 7.21 / 398.27 | 6 | 133 |
Average= | 6.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 57 | 14.84 | 508 | 430 | 0.43 / 384.13 | 6 | 62 |
2 | 3 | 1037.92 | 1 | 14.98 | 1757 | 26 | 0.46 / 384.16 | 6 | 12 |
3 | 7 | 2010.32 | 41 | 14.71 | 2908 | 1754 | 2.21 / 385.91 | 12 | 53 |
4 | 13 | 1985.36 | 20 | 14.66 | 2934 | 860 | 3.07 / 386.77 | 5 | 56 |
5 | 13 | 1915.36 | 20 | 14.58 | 2840 | 828 | 3.90 / 387.60 | 6 | 61 |
6 | 13 | 1824.72 | 20 | 14.54 | 2727 | 793 | 4.69 / 388.40 | 6 | 61 |
7 | 13 | 1183.36 | 20 | 14.65 | 1875 | 549 | 5.24 / 388.94 | 6 | 71 |
8 | 13 | 502.44 | 20 | 14.83 | 1007 | 299 | 5.54 / 389.24 | 6 | 80 |
9 | 13 | 17.24 | 20 | 14.98 | 370 | 111 | 5.65 / 389.35 | 6 | 64 |
10 | 8 | -6.56 | 353 | 14.90 | 324 | 1704 | 7.35 / 391.06 | 6 | 131 |
Average= | 6.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 70 | 14.83 | 487 | 506 | 0.51 / 376.88 | 6 | 63 |
2 | 3 | 611.64 | -6 | 15.34 | 3 | 0 | 0.00 / 376.88 | 6 | 63 |
3 | 7 | 2019.04 | 40 | 14.72 | 2903 | 1709 | 2.21 / 378.59 | 63 | 53 |
4 | 13 | 1997.04 | 20 | 14.67 | 2905 | 852 | 3.07 / 379.44 | 5 | 54 |
5 | 13 | 1920.60 | 20 | 14.61 | 2811 | 821 | 3.89 / 380.26 | 5 | 57 |
6 | 13 | 1726.16 | 20 | 14.58 | 2557 | 746 | 4.63 / 381.01 | 5 | 60 |
7 | 13 | 1091.96 | 20 | 14.68 | 1737 | 510 | 5.14 / 381.52 | 6 | 70 |
8 | 13 | 560.52 | 20 | 14.82 | 1075 | 319 | 5.46 / 381.84 | 6 | 79 |
9 | 8 | -0.28 | 390 | 14.90 | 321 | 1865 | 7.33 / 383.70 | 6 | 132 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 56 | 14.87 | 410 | 341 | 0.34 / 369.21 | 6 | 20 |
2 | 10 | 1021.40 | 6 | 14.83 | 1668 | 148 | 0.49 / 369.36 | 6 | 59 |
3 | 10 | 1071.64 | 5 | 14.81 | 1751 | 130 | 0.62 / 369.49 | 6 | 55 |
4 | 10 | 1108.16 | 3 | 14.81 | 1826 | 81 | 0.70 / 369.57 | 6 | 47 |
5 | 3 | 1086.00 | 2 | 14.93 | 1782 | 53 | 0.75 / 369.62 | 6 | 34 |
6 | 7 | 2025.16 | 40 | 14.73 | 2817 | 1660 | 2.41 / 371.28 | 34 | 50 |
7 | 13 | 1995.84 | 20 | 14.69 | 2814 | 827 | 3.24 / 372.11 | 6 | 52 |
8 | 13 | 1918.40 | 20 | 14.63 | 2738 | 801 | 4.04 / 372.91 | 6 | 57 |
9 | 13 | 1721.84 | 20 | 14.60 | 2476 | 723 | 4.76 / 373.63 | 6 | 59 |
10 | 13 | 983.72 | 20 | 14.73 | 1552 | 457 | 5.22 / 374.09 | 6 | 68 |
11 | 13 | 566.32 | 20 | 14.83 | 1046 | 310 | 5.53 / 374.40 | 6 | 64 |
12 | 13 | 71.44 | 20 | 14.99 | 406 | 122 | 5.65 / 374.52 | 6 | 44 |
13 | 8 | -4.88 | 390 | 14.91 | 319 | 1855 | 7.51 / 376.38 | 6 | 129 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 57 | 14.85 | 503 | 426 | 0.43 / 362.11 | 6 | 64 |
2 | 3 | 958.28 | -1 | 15.35 | 3 | 0 | 0.00 / 362.11 | 6 | 64 |
3 | 7 | 2019.48 | 40 | 14.72 | 2895 | 1705 | 2.13 / 363.82 | 64 | 52 |
4 | 13 | 1998.60 | 20 | 14.67 | 2891 | 848 | 2.98 / 364.67 | 6 | 56 |
5 | 13 | 1921.20 | 20 | 14.62 | 2810 | 822 | 3.80 / 365.49 | 6 | 59 |
6 | 13 | 1616.24 | 20 | 14.60 | 2437 | 712 | 4.51 / 366.20 | 6 | 64 |
7 | 13 | 1005.12 | 20 | 14.72 | 1650 | 486 | 5.00 / 366.69 | 6 | 71 |
8 | 13 | 372.72 | 20 | 14.89 | 839 | 250 | 5.25 / 366.93 | 6 | 81 |
9 | 8 | -6.12 | 400 | 14.91 | 324 | 1932 | 7.18 / 368.87 | 6 | 123 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 57 | 14.85 | 482 | 408 | 0.41 / 354.82 | 6 | 59 |
2 | 7 | 2020.52 | 40 | 14.72 | 2896 | 1705 | 2.11 / 356.52 | 6 | 52 |
3 | 13 | 1999.40 | 20 | 14.67 | 2907 | 853 | 2.97 / 357.37 | 6 | 55 |
4 | 13 | 1933.32 | 20 | 14.60 | 2833 | 827 | 3.79 / 358.20 | 6 | 59 |
5 | 13 | 1839.44 | 20 | 14.56 | 2713 | 790 | 4.58 / 358.99 | 6 | 60 |
6 | 13 | 1165.84 | 20 | 14.68 | 1837 | 539 | 5.12 / 359.53 | 6 | 70 |
7 | 13 | 496.52 | 20 | 14.86 | 995 | 296 | 5.42 / 359.83 | 6 | 80 |
8 | 13 | 39.32 | 20 | 15.00 | 398 | 119 | 5.54 / 359.95 | 6 | 69 |
9 | 8 | -4.52 | 357 | 14.92 | 327 | 1742 | 7.28 / 361.69 | 6 | 130 |
Average= | 6.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 56 | 14.86 | 478 | 398 | 0.40 / 347.58 | 6 | 58 |
2 | 3 | 1022.40 | 1 | 15.04 | 1729 | 26 | 0.42 / 347.61 | 6 | 6 |
3 | 7 | 2007.68 | 40 | 14.72 | 2891 | 1702 | 2.13 / 349.31 | 6 | 52 |
4 | 13 | 1984.68 | 20 | 14.68 | 2875 | 844 | 2.97 / 350.16 | 5 | 54 |
5 | 13 | 1911.64 | 20 | 14.62 | 2789 | 816 | 3.79 / 350.97 | 5 | 58 |
6 | 13 | 1717.92 | 20 | 14.58 | 2569 | 749 | 4.53 / 351.72 | 6 | 62 |
7 | 13 | 997.40 | 20 | 14.72 | 1632 | 480 | 5.02 / 352.20 | 6 | 72 |
8 | 13 | 564.84 | 20 | 14.83 | 1094 | 324 | 5.34 / 352.53 | 6 | 82 |
9 | 13 | 13.32 | 20 | 15.01 | 363 | 109 | 5.45 / 352.63 | 6 | 66 |
10 | 8 | -4.84 | 368 | 14.92 | 323 | 1773 | 7.22 / 354.41 | 6 | 129 |
Average= | 6.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 55 | 14.87 | 491 | 402 | 0.40 / 340.34 | 6 | 56 |
2 | 3 | 1039.32 | 1 | 15.01 | 1755 | 26 | 0.43 / 340.36 | 6 | 12 |
3 | 7 | 2006.80 | 41 | 14.73 | 2857 | 1725 | 2.15 / 342.09 | 12 | 51 |
4 | 13 | 1979.92 | 20 | 14.70 | 2857 | 840 | 2.99 / 342.93 | 6 | 55 |
5 | 13 | 1899.76 | 20 | 14.63 | 2766 | 809 | 3.80 / 343.74 | 6 | 59 |
6 | 13 | 1600.32 | 20 | 14.62 | 2385 | 697 | 4.50 / 344.44 | 6 | 65 |
7 | 13 | 1287.56 | 20 | 14.64 | 1989 | 582 | 5.08 / 345.02 | 6 | 68 |
8 | 13 | 521.40 | 20 | 14.85 | 1015 | 301 | 5.38 / 345.32 | 6 | 72 |
9 | 13 | 44.48 | 20 | 15.00 | 402 | 121 | 5.50 / 345.44 | 6 | 70 |
10 | 8 | -2.60 | 361 | 14.92 | 324 | 1745 | 7.25 / 347.19 | 6 | 130 |
Average= | 6.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 54 | 14.88 | 506 | 407 | 0.41 / 333.00 | 6 | 59 |
2 | 3 | 1069.56 | 2 | 14.97 | 1787 | 54 | 0.46 / 333.05 | 6 | 31 |
3 | 7 | 2020.20 | 40 | 14.72 | 2917 | 1718 | 2.18 / 334.77 | 31 | 51 |
4 | 13 | 2000.60 | 20 | 14.68 | 2920 | 857 | 3.03 / 335.62 | 6 | 55 |
5 | 13 | 1925.84 | 20 | 14.62 | 2834 | 829 | 3.86 / 336.45 | 6 | 58 |
6 | 13 | 1729.64 | 20 | 14.59 | 2587 | 755 | 4.62 / 337.21 | 6 | 62 |
7 | 13 | 1097.84 | 20 | 14.71 | 1766 | 520 | 5.14 / 337.73 | 6 | 70 |
8 | 13 | 574.24 | 20 | 14.84 | 1094 | 325 | 5.46 / 338.05 | 6 | 80 |
9 | 13 | 64.12 | 20 | 15.00 | 429 | 129 | 5.59 / 338.18 | 6 | 73 |
10 | 8 | -6.68 | 364 | 14.93 | 323 | 1755 | 7.35 / 339.94 | 6 | 130 |
Average= | 6.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 55 | 14.90 | 482 | 395 | 0.39 / 325.80 | 6 | 49 |
2 | 3 | 966.12 | -1 | 15.37 | 3 | 0 | 0.00 / 325.80 | 6 | 49 |
3 | 7 | 2006.36 | 41 | 14.73 | 2864 | 1730 | 2.12 / 327.53 | 49 | 52 |
4 | 13 | 1982.60 | 20 | 14.69 | 2866 | 842 | 2.97 / 328.37 | 5 | 54 |
5 | 13 | 1914.72 | 20 | 14.63 | 2779 | 813 | 3.78 / 329.18 | 6 | 58 |
6 | 13 | 1824.60 | 20 | 14.58 | 2674 | 780 | 4.56 / 329.96 | 6 | 59 |
7 | 13 | 954.68 | 20 | 14.76 | 1580 | 466 | 5.03 / 330.43 | 6 | 71 |
8 | 13 | 516.64 | 20 | 14.87 | 1029 | 306 | 5.33 / 330.74 | 6 | 80 |
9 | 13 | 39.04 | 20 | 15.01 | 397 | 119 | 5.45 / 330.86 | 6 | 70 |
10 | 8 | -6.68 | 357 | 14.94 | 325 | 1733 | 7.18 / 332.59 | 6 | 131 |
Average= | 6.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.96 | 55 | 14.89 | 513 | 420 | 0.42 / 318.74 | 6 | 53 |
2 | 7 | 2007.80 | 40 | 14.73 | 2904 | 1711 | 2.13 / 320.45 | 53 | 51 |
3 | 13 | 1981.20 | 20 | 14.69 | 2883 | 847 | 2.98 / 321.30 | 6 | 54 |
4 | 13 | 1907.00 | 20 | 14.63 | 2799 | 819 | 3.80 / 322.12 | 6 | 57 |
5 | 13 | 1720.36 | 20 | 14.59 | 2581 | 753 | 4.55 / 322.87 | 6 | 62 |
6 | 13 | 1197.64 | 20 | 14.68 | 1885 | 553 | 5.10 / 323.42 | 6 | 68 |
7 | 13 | 351.28 | 20 | 14.93 | 819 | 245 | 5.35 / 323.67 | 6 | 83 |
8 | 13 | 34.88 | 20 | 15.02 | 397 | 119 | 5.47 / 323.79 | 6 | 78 |
9 | 8 | -6.88 | 333 | 14.95 | 325 | 1618 | 7.09 / 325.40 | 6 | 130 |
Average= | 6.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 55 | 14.91 | 508 | 417 | 0.42 / 311.67 | 6 | 54 |
2 | 7 | 2008.32 | 40 | 14.73 | 2888 | 1702 | 2.12 / 313.37 | 54 | 52 |
3 | 13 | 1990.28 | 20 | 14.69 | 2892 | 850 | 2.97 / 314.22 | 6 | 53 |
4 | 13 | 1923.40 | 20 | 14.63 | 2824 | 826 | 3.79 / 315.05 | 6 | 57 |
5 | 13 | 1521.96 | 20 | 14.64 | 2315 | 678 | 4.47 / 315.72 | 6 | 64 |
6 | 13 | 1214.28 | 20 | 14.69 | 1906 | 560 | 5.03 / 316.28 | 6 | 68 |
7 | 13 | 452.36 | 20 | 14.90 | 942 | 281 | 5.31 / 316.56 | 6 | 80 |
8 | 13 | 13.96 | 20 | 15.03 | 363 | 109 | 5.42 / 316.67 | 6 | 78 |
9 | 8 | -4.00 | 342 | 14.95 | 322 | 1646 | 7.07 / 318.32 | 6 | 129 |
Average= | 6.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 54 | 14.90 | 509 | 410 | 0.41 / 304.70 | 6 | 52 |
2 | 3 | 1023.64 | 1 | 15.03 | 1766 | 27 | 0.44 / 304.73 | 6 | 7 |
3 | 7 | 2010.60 | 40 | 14.74 | 2910 | 1716 | 2.15 / 306.44 | 7 | 54 |
4 | 13 | 1995.60 | 20 | 14.69 | 2896 | 851 | 3.00 / 307.29 | 6 | 53 |
5 | 13 | 1922.84 | 20 | 14.64 | 2825 | 827 | 3.83 / 308.12 | 6 | 58 |
6 | 13 | 1626.52 | 20 | 14.64 | 2436 | 713 | 4.54 / 308.83 | 6 | 61 |
7 | 13 | 981.52 | 20 | 14.76 | 1612 | 476 | 5.02 / 309.31 | 6 | 71 |
8 | 13 | 440.52 | 20 | 14.91 | 925 | 276 | 5.29 / 309.58 | 6 | 80 |
9 | 13 | 51.44 | 20 | 15.03 | 415 | 125 | 5.42 / 309.71 | 6 | 71 |
10 | 8 | -6.52 | 321 | 14.96 | 321 | 1541 | 6.96 / 311.25 | 6 | 132 |
Average= | 6.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 54 | 14.92 | 493 | 397 | 0.40 / 297.42 | 6 | 46 |
2 | 7 | 2007.08 | 40 | 14.75 | 2870 | 1693 | 2.09 / 299.11 | 46 | 53 |
3 | 13 | 1987.80 | 20 | 14.71 | 2860 | 841 | 2.93 / 299.96 | 6 | 54 |
4 | 13 | 1919.36 | 20 | 14.65 | 2777 | 814 | 3.75 / 300.77 | 6 | 55 |
5 | 13 | 1823.12 | 20 | 14.60 | 2681 | 783 | 4.53 / 301.55 | 6 | 60 |
6 | 13 | 1169.68 | 20 | 14.72 | 1836 | 541 | 5.07 / 302.09 | 6 | 70 |
7 | 13 | 629.52 | 20 | 14.86 | 1159 | 344 | 5.41 / 302.44 | 6 | 76 |
8 | 13 | 83.80 | 20 | 15.03 | 449 | 135 | 5.55 / 302.57 | 6 | 70 |
9 | 8 | -2.84 | 359 | 14.96 | 320 | 1719 | 7.27 / 304.29 | 6 | 129 |
Average= | 6.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 54 | 14.91 | 492 | 396 | 0.40 / 290.33 | 6 | 48 |
2 | 7 | 2014.68 | 40 | 14.74 | 2906 | 1713 | 2.11 / 292.04 | 48 | 53 |
3 | 13 | 2000.32 | 20 | 14.70 | 2896 | 851 | 2.96 / 292.89 | 6 | 55 |
4 | 13 | 1931.52 | 20 | 14.63 | 2803 | 820 | 3.78 / 293.71 | 6 | 57 |
5 | 13 | 1626.24 | 20 | 14.65 | 2414 | 707 | 4.49 / 294.42 | 6 | 61 |
6 | 13 | 1101.64 | 20 | 14.75 | 1734 | 512 | 5.00 / 294.93 | 6 | 70 |
7 | 13 | 455.56 | 20 | 14.91 | 949 | 283 | 5.28 / 295.21 | 6 | 79 |
8 | 13 | 17.12 | 20 | 15.04 | 374 | 112 | 5.40 / 295.33 | 6 | 67 |
9 | 8 | -6.64 | 353 | 14.97 | 321 | 1696 | 7.09 / 297.02 | 6 | 129 |
Average= | 6.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 54 | 14.92 | 479 | 386 | 0.39 / 283.18 | 6 | 50 |
2 | 3 | 1018.52 | 1 | 15.06 | 1770 | 27 | 0.41 / 283.21 | 6 | 6 |
3 | 7 | 2006.80 | 40 | 14.76 | 2862 | 1690 | 2.10 / 284.90 | 6 | 52 |
4 | 13 | 1981.88 | 20 | 14.72 | 2853 | 840 | 2.94 / 285.74 | 6 | 56 |
5 | 13 | 1908.72 | 20 | 14.65 | 2769 | 811 | 3.75 / 286.55 | 6 | 58 |
6 | 13 | 1720.84 | 20 | 14.62 | 2572 | 752 | 4.51 / 287.30 | 6 | 63 |
7 | 13 | 971.12 | 20 | 14.79 | 1592 | 471 | 4.98 / 287.77 | 6 | 72 |
8 | 13 | 532.24 | 20 | 14.89 | 1053 | 314 | 5.29 / 288.08 | 6 | 81 |
9 | 13 | 24.88 | 20 | 15.05 | 384 | 116 | 5.41 / 288.20 | 6 | 71 |
10 | 8 | -6.80 | 357 | 14.97 | 324 | 1732 | 7.14 / 289.93 | 6 | 147 |
Average= | 6.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 55 | 14.92 | 502 | 412 | 0.41 / 275.98 | 6 | 51 |
2 | 3 | 963.96 | -1 | 15.38 | 3 | 0 | 0.00 / 275.98 | 6 | 51 |
3 | 7 | 2009.52 | 40 | 14.75 | 2885 | 1702 | 2.11 / 277.68 | 51 | 53 |
4 | 13 | 1992.88 | 20 | 14.71 | 2868 | 844 | 2.96 / 278.52 | 6 | 55 |
5 | 13 | 1922.56 | 20 | 14.64 | 2791 | 817 | 3.78 / 279.34 | 6 | 57 |
6 | 13 | 1727.04 | 20 | 14.63 | 2562 | 750 | 4.52 / 280.09 | 6 | 61 |
7 | 13 | 1195.00 | 20 | 14.72 | 1895 | 558 | 5.08 / 280.65 | 6 | 69 |
8 | 13 | 337.96 | 20 | 14.97 | 792 | 237 | 5.32 / 280.89 | 6 | 80 |
9 | 13 | 29.80 | 20 | 15.05 | 390 | 117 | 5.44 / 281.00 | 6 | 70 |
10 | 8 | -3.20 | 368 | 14.97 | 325 | 1790 | 7.23 / 282.79 | 6 | 142 |
Average= | 6.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 56 | 14.92 | 500 | 418 | 0.42 / 268.86 | 6 | 54 |
2 | 7 | 2007.48 | 40 | 14.75 | 2894 | 1707 | 2.13 / 270.57 | 54 | 53 |
3 | 13 | 1983.80 | 20 | 14.72 | 2869 | 845 | 2.97 / 271.41 | 6 | 57 |
4 | 13 | 1912.00 | 20 | 14.65 | 2800 | 820 | 3.79 / 272.23 | 6 | 58 |
5 | 13 | 1718.68 | 20 | 14.63 | 2574 | 753 | 4.54 / 272.99 | 6 | 63 |
6 | 13 | 978.24 | 20 | 14.80 | 1609 | 476 | 5.02 / 273.46 | 6 | 72 |
7 | 13 | 351.44 | 20 | 14.97 | 811 | 243 | 5.26 / 273.71 | 6 | 81 |
8 | 13 | 29.04 | 20 | 15.05 | 396 | 119 | 5.38 / 273.82 | 6 | 74 |
9 | 8 | -6.72 | 360 | 14.98 | 323 | 1742 | 7.12 / 275.57 | 6 | 136 |
Average= | 6.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 56 | 14.93 | 494 | 413 | 0.41 / 261.61 | 6 | 54 |
2 | 7 | 2008.04 | 40 | 14.75 | 2886 | 1703 | 2.12 / 263.31 | 54 | 51 |
3 | 13 | 1978.16 | 20 | 14.70 | 2895 | 851 | 2.97 / 264.16 | 6 | 53 |
4 | 13 | 1897.92 | 20 | 14.65 | 2786 | 816 | 3.78 / 264.98 | 6 | 58 |
5 | 13 | 1700.52 | 20 | 14.64 | 2523 | 739 | 4.52 / 265.72 | 6 | 62 |
6 | 13 | 1172.00 | 20 | 14.74 | 1850 | 545 | 5.07 / 266.26 | 6 | 69 |
7 | 13 | 526.40 | 20 | 14.92 | 1031 | 308 | 5.37 / 266.57 | 6 | 81 |
8 | 13 | 41.08 | 20 | 15.05 | 403 | 121 | 5.50 / 266.69 | 6 | 73 |
9 | 8 | -4.36 | 359 | 14.98 | 326 | 1753 | 7.25 / 268.44 | 6 | 129 |
Average= | 6.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 56 | 14.92 | 508 | 424 | 0.42 / 254.35 | 6 | 61 |
2 | 7 | 2007.56 | 40 | 14.76 | 2879 | 1700 | 2.12 / 256.05 | 61 | 53 |
3 | 13 | 1985.16 | 20 | 14.71 | 2894 | 851 | 2.98 / 256.90 | 6 | 55 |
4 | 13 | 1911.52 | 20 | 14.65 | 2808 | 823 | 3.80 / 257.73 | 6 | 58 |
5 | 13 | 1816.04 | 20 | 14.61 | 2675 | 782 | 4.58 / 258.51 | 6 | 60 |
6 | 13 | 1168.08 | 20 | 14.75 | 1855 | 547 | 5.13 / 259.05 | 6 | 70 |
7 | 13 | 420.16 | 20 | 14.96 | 899 | 269 | 5.40 / 259.32 | 6 | 79 |
8 | 13 | 24.56 | 20 | 15.07 | 386 | 116 | 5.51 / 259.44 | 6 | 75 |
9 | 8 | -6.68 | 359 | 14.99 | 326 | 1754 | 7.27 / 261.19 | 6 | 130 |
Average= | 6.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 56 | 14.93 | 493 | 412 | 0.41 / 247.07 | 6 | 59 |
2 | 7 | 2007.52 | 41 | 14.76 | 2883 | 1745 | 2.16 / 248.82 | 59 | 51 |
3 | 13 | 1978.96 | 20 | 14.71 | 2888 | 850 | 3.01 / 249.67 | 6 | 54 |
4 | 13 | 1902.40 | 20 | 14.65 | 2792 | 818 | 3.82 / 250.48 | 6 | 56 |
5 | 13 | 1708.40 | 20 | 14.64 | 2549 | 746 | 4.57 / 251.23 | 6 | 60 |
6 | 13 | 1165.40 | 20 | 14.75 | 1845 | 544 | 5.12 / 251.78 | 6 | 69 |
7 | 13 | 500.48 | 20 | 14.93 | 1011 | 302 | 5.42 / 252.08 | 6 | 82 |
8 | 13 | 35.52 | 20 | 15.07 | 392 | 118 | 5.54 / 252.20 | 6 | 69 |
9 | 8 | -6.64 | 361 | 14.99 | 320 | 1732 | 7.27 / 253.93 | 6 | 130 |
Average= | 6.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 58 | 14.92 | 500 | 433 | 0.43 / 240.08 | 6 | 59 |
2 | 3 | 935.64 | -1 | 15.39 | 3 | 0 | 0.00 / 240.08 | 6 | 59 |
3 | 7 | 2008.92 | 40 | 14.76 | 2883 | 1702 | 2.13 / 241.78 | 59 | 51 |
4 | 13 | 1983.12 | 20 | 14.71 | 2906 | 855 | 2.99 / 242.64 | 5 | 55 |
5 | 13 | 1907.56 | 20 | 14.65 | 2807 | 822 | 3.81 / 243.46 | 6 | 58 |
6 | 13 | 1614.20 | 20 | 14.67 | 2416 | 709 | 4.52 / 244.17 | 5 | 64 |
7 | 13 | 890.64 | 20 | 14.85 | 1489 | 442 | 4.96 / 244.61 | 6 | 73 |
8 | 13 | 277.16 | 20 | 15.01 | 723 | 217 | 5.18 / 244.83 | 6 | 81 |
9 | 8 | -6.48 | 379 | 15.00 | 322 | 1831 | 7.01 / 246.66 | 6 | 130 |
Average= | 6.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 63 | 14.93 | 480 | 451 | 0.45 / 232.88 | 6 | 60 |
2 | 3 | 848.72 | -2 | 15.39 | 3 | 0 | 0.00 / 232.88 | 6 | 60 |
3 | 7 | 2006.60 | 40 | 14.76 | 2873 | 1696 | 2.15 / 234.58 | 60 | 53 |
4 | 13 | 1981.80 | 20 | 14.72 | 2867 | 844 | 2.99 / 235.42 | 6 | 56 |
5 | 13 | 1907.88 | 20 | 14.66 | 2798 | 820 | 3.81 / 236.24 | 5 | 58 |
6 | 13 | 1709.12 | 20 | 14.65 | 2540 | 744 | 4.56 / 236.99 | 6 | 63 |
7 | 13 | 1167.04 | 20 | 14.76 | 1849 | 546 | 5.10 / 237.53 | 6 | 68 |
8 | 13 | 382.28 | 20 | 14.98 | 861 | 258 | 5.36 / 237.79 | 6 | 79 |
9 | 8 | -6.52 | 381 | 15.00 | 325 | 1857 | 7.22 / 239.65 | 6 | 132 |
Average= | 6.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 57 | 14.93 | 477 | 406 | 0.41 / 225.25 | 6 | 50 |
2 | 10 | 1063.20 | 4 | 14.91 | 1733 | 103 | 0.51 / 225.35 | 6 | 57 |
3 | 3 | 1105.12 | 3 | 14.98 | 1786 | 80 | 0.59 / 225.43 | 5 | 43 |
4 | 7 | 2019.28 | 40 | 14.77 | 2854 | 1686 | 2.28 / 227.12 | 43 | 49 |
5 | 13 | 2001.04 | 20 | 14.72 | 2889 | 851 | 3.13 / 227.97 | 6 | 55 |
6 | 13 | 1926.60 | 20 | 14.67 | 2810 | 824 | 3.95 / 228.79 | 6 | 56 |
7 | 13 | 1724.52 | 20 | 14.66 | 2528 | 741 | 4.69 / 229.53 | 6 | 61 |
8 | 13 | 1415.52 | 20 | 14.69 | 2151 | 632 | 5.32 / 230.16 | 6 | 66 |
9 | 13 | 632.36 | 20 | 14.91 | 1152 | 344 | 5.67 / 230.51 | 6 | 72 |
10 | 13 | 20.20 | 20 | 15.08 | 377 | 114 | 5.78 / 230.62 | 6 | 72 |
11 | 8 | -6.60 | 368 | 15.00 | 328 | 1811 | 7.59 / 232.43 | 6 | 133 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.36 | 59 | 14.93 | 521 | 459 | 0.46 / 217.90 | 6 | 60 |
2 | 3 | 939.84 | -1 | 15.39 | 3 | 0 | 0.00 / 217.90 | 6 | 60 |
3 | 7 | 2024.28 | 40 | 14.76 | 2917 | 1722 | 2.18 / 219.63 | 60 | 55 |
4 | 13 | 1994.96 | 20 | 14.72 | 2895 | 852 | 3.03 / 220.48 | 5 | 56 |
5 | 13 | 1916.24 | 20 | 14.66 | 2805 | 822 | 3.86 / 221.30 | 6 | 59 |
6 | 13 | 1714.16 | 20 | 14.65 | 2573 | 754 | 4.61 / 222.05 | 6 | 63 |
7 | 13 | 1068.64 | 20 | 14.80 | 1730 | 512 | 5.12 / 222.57 | 6 | 71 |
8 | 13 | 522.88 | 20 | 14.94 | 1043 | 312 | 5.43 / 222.88 | 6 | 82 |
9 | 8 | -3.24 | 394 | 15.00 | 332 | 1962 | 7.40 / 224.84 | 6 | 133 |
Average= | 6.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 59 | 14.94 | 492 | 434 | 0.43 / 210.71 | 6 | 62 |
2 | 7 | 2026.16 | 40 | 14.76 | 2918 | 1723 | 2.16 / 212.43 | 62 | 53 |
3 | 13 | 1999.52 | 20 | 14.72 | 2910 | 857 | 3.01 / 213.29 | 6 | 56 |
4 | 13 | 1928.96 | 20 | 14.65 | 2834 | 830 | 3.84 / 214.12 | 6 | 60 |
5 | 13 | 1630.04 | 20 | 14.67 | 2460 | 722 | 4.57 / 214.84 | 6 | 63 |
6 | 13 | 987.60 | 20 | 14.83 | 1620 | 480 | 5.05 / 215.32 | 6 | 73 |
7 | 13 | 333.92 | 20 | 15.00 | 795 | 238 | 5.28 / 215.56 | 6 | 81 |
8 | 8 | -5.60 | 381 | 15.01 | 330 | 1887 | 7.17 / 217.44 | 6 | 133 |
Average= | 6.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 59 | 14.94 | 499 | 440 | 0.44 / 203.50 | 6 | 64 |
2 | 7 | 2017.12 | 40 | 14.76 | 2913 | 1720 | 2.16 / 205.22 | 64 | 53 |
3 | 13 | 1993.04 | 20 | 14.72 | 2919 | 859 | 3.02 / 206.08 | 6 | 55 |
4 | 13 | 1921.08 | 20 | 14.67 | 2815 | 826 | 3.84 / 206.90 | 6 | 57 |
5 | 13 | 1726.24 | 20 | 14.66 | 2578 | 756 | 4.60 / 207.66 | 6 | 63 |
6 | 13 | 1075.76 | 20 | 14.81 | 1745 | 517 | 5.12 / 208.18 | 5 | 71 |
7 | 13 | 432.28 | 20 | 14.97 | 929 | 278 | 5.40 / 208.45 | 6 | 82 |
8 | 8 | -6.60 | 368 | 15.02 | 329 | 1819 | 7.21 / 210.27 | 6 | 133 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 58 | 14.95 | 494 | 428 | 0.43 / 196.27 | 6 | 66 |
2 | 3 | 1044.40 | 1 | 15.03 | 1764 | 27 | 0.45 / 196.30 | 5 | 18 |
3 | 7 | 2007.92 | 40 | 14.76 | 2898 | 1711 | 2.17 / 198.01 | 18 | 54 |
4 | 13 | 1980.00 | 20 | 14.73 | 2892 | 852 | 3.02 / 198.86 | 6 | 56 |
5 | 13 | 1904.56 | 20 | 14.67 | 2805 | 823 | 3.84 / 199.68 | 6 | 58 |
6 | 13 | 1597.48 | 20 | 14.69 | 2425 | 712 | 4.55 / 200.40 | 6 | 65 |
7 | 13 | 1065.76 | 20 | 14.81 | 1730 | 512 | 5.07 / 200.91 | 6 | 71 |
8 | 13 | 426.04 | 20 | 14.98 | 927 | 278 | 5.34 / 201.19 | 6 | 83 |
9 | 8 | -6.68 | 379 | 15.02 | 329 | 1873 | 7.22 / 203.06 | 6 | 131 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 63 | 14.95 | 482 | 454 | 0.45 / 189.12 | 6 | 63 |
2 | 3 | 861.36 | -2 | 15.40 | 3 | 0 | 0.00 / 189.12 | 6 | 63 |
3 | 7 | 2006.32 | 40 | 14.77 | 2919 | 1725 | 2.18 / 190.85 | 63 | 53 |
4 | 13 | 1987.28 | 20 | 14.73 | 2909 | 857 | 3.04 / 191.71 | 5 | 56 |
5 | 13 | 1908.80 | 20 | 14.68 | 2818 | 827 | 3.86 / 192.53 | 6 | 58 |
6 | 13 | 1612.52 | 20 | 14.69 | 2443 | 718 | 4.58 / 193.25 | 6 | 65 |
7 | 13 | 888.56 | 20 | 14.87 | 1509 | 449 | 5.03 / 193.70 | 6 | 73 |
8 | 13 | 572.72 | 20 | 14.94 | 1101 | 329 | 5.36 / 194.03 | 6 | 81 |
9 | 8 | -6.68 | 366 | 15.02 | 330 | 1814 | 7.17 / 195.84 | 6 | 129 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 62 | 14.94 | 490 | 454 | 0.45 / 181.83 | 6 | 59 |
2 | 3 | 1025.44 | 1 | 15.06 | 1775 | 27 | 0.48 / 181.85 | 6 | 6 |
3 | 7 | 2022.60 | 41 | 14.76 | 2904 | 1757 | 2.24 / 183.61 | 6 | 51 |
4 | 13 | 1995.92 | 20 | 14.72 | 2921 | 860 | 3.10 / 184.47 | 5 | 52 |
5 | 13 | 1915.40 | 20 | 14.68 | 2816 | 827 | 3.92 / 185.30 | 6 | 57 |
6 | 13 | 1599.52 | 20 | 14.71 | 2402 | 707 | 4.63 / 186.00 | 6 | 64 |
7 | 13 | 1082.64 | 20 | 14.82 | 1742 | 516 | 5.15 / 186.52 | 6 | 71 |
8 | 13 | 439.88 | 20 | 14.99 | 920 | 276 | 5.42 / 186.80 | 6 | 79 |
9 | 13 | 46.24 | 20 | 15.09 | 418 | 126 | 5.55 / 186.92 | 6 | 70 |
10 | 8 | -5.60 | 357 | 15.02 | 326 | 1748 | 7.30 / 188.67 | 6 | 130 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 62 | 14.95 | 502 | 465 | 0.47 / 174.49 | 6 | 65 |
2 | 7 | 2011.20 | 41 | 14.77 | 2908 | 1761 | 2.23 / 176.25 | 65 | 54 |
3 | 13 | 1989.24 | 20 | 14.72 | 2933 | 863 | 3.09 / 177.11 | 6 | 56 |
4 | 13 | 1911.28 | 20 | 14.68 | 2820 | 828 | 3.92 / 177.94 | 5 | 59 |
5 | 13 | 1616.04 | 20 | 14.69 | 2452 | 720 | 4.64 / 178.66 | 6 | 64 |
6 | 13 | 1199.44 | 20 | 14.78 | 1901 | 562 | 5.20 / 179.22 | 6 | 71 |
7 | 13 | 335.36 | 20 | 15.02 | 807 | 242 | 5.44 / 179.46 | 6 | 85 |
8 | 13 | 13.96 | 20 | 15.10 | 386 | 117 | 5.56 / 179.58 | 6 | 68 |
9 | 8 | -4.96 | 366 | 15.02 | 326 | 1792 | 7.35 / 181.37 | 6 | 133 |
Average= | 6.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 61 | 14.96 | 501 | 457 | 0.46 / 167.36 | 6 | 62 |
2 | 7 | 2020.64 | 40 | 14.77 | 2913 | 1721 | 2.18 / 169.08 | 6 | 52 |
3 | 13 | 1986.28 | 20 | 14.73 | 2908 | 857 | 3.03 / 169.93 | 5 | 55 |
4 | 13 | 1904.64 | 20 | 14.68 | 2805 | 824 | 3.86 / 170.76 | 6 | 58 |
5 | 13 | 1703.00 | 20 | 14.67 | 2550 | 748 | 4.61 / 171.51 | 6 | 62 |
6 | 13 | 838.04 | 20 | 14.89 | 1446 | 431 | 5.04 / 171.94 | 6 | 72 |
7 | 13 | 416.56 | 20 | 15.00 | 907 | 272 | 5.31 / 172.21 | 6 | 82 |
8 | 8 | -6.60 | 359 | 15.03 | 336 | 1813 | 7.12 / 174.02 | 6 | 131 |
Average= | 6.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 61 | 14.94 | 511 | 466 | 0.47 / 160.10 | 6 | 63 |
2 | 7 | 2014.80 | 40 | 14.77 | 2941 | 1738 | 2.20 / 161.84 | 6 | 52 |
3 | 13 | 1982.84 | 20 | 14.74 | 2911 | 858 | 3.06 / 162.70 | 6 | 58 |
4 | 13 | 1903.76 | 20 | 14.69 | 2830 | 831 | 3.89 / 163.53 | 6 | 61 |
5 | 13 | 1608.88 | 20 | 14.72 | 2432 | 716 | 4.61 / 164.24 | 6 | 63 |
6 | 13 | 988.84 | 20 | 14.86 | 1639 | 487 | 5.10 / 164.73 | 6 | 71 |
7 | 13 | 354.24 | 20 | 15.02 | 843 | 253 | 5.35 / 164.98 | 6 | 83 |
8 | 8 | -6.80 | 379 | 15.03 | 336 | 1914 | 7.26 / 166.90 | 6 | 134 |
Average= | 6.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 57 | 14.96 | 509 | 434 | 0.43 / 152.49 | 6 | 63 |
2 | 10 | 1036.72 | 3 | 14.96 | 1714 | 77 | 0.51 / 152.56 | 6 | 46 |
3 | 3 | 1069.80 | 2 | 15.01 | 1812 | 54 | 0.57 / 152.62 | 6 | 34 |
4 | 7 | 2028.08 | 40 | 14.76 | 2952 | 1743 | 2.31 / 154.36 | 34 | 52 |
5 | 13 | 2008.08 | 20 | 14.72 | 2944 | 867 | 3.17 / 155.23 | 6 | 57 |
6 | 13 | 1939.20 | 20 | 14.68 | 2845 | 835 | 4.01 / 156.06 | 6 | 58 |
7 | 13 | 1742.76 | 20 | 14.68 | 2587 | 760 | 4.77 / 156.82 | 6 | 61 |
8 | 13 | 1076.88 | 20 | 14.83 | 1745 | 518 | 5.29 / 157.34 | 6 | 71 |
9 | 13 | 335.24 | 20 | 15.03 | 806 | 242 | 5.53 / 157.58 | 6 | 82 |
10 | 13 | 63.64 | 20 | 15.10 | 448 | 135 | 5.66 / 157.72 | 6 | 75 |
11 | 13 | 37.00 | 20 | 15.10 | 418 | 126 | 5.79 / 157.84 | 6 | 71 |
12 | 13 | 11.04 | 20 | 15.09 | 386 | 116 | 5.91 / 157.96 | 6 | 74 |
13 | 8 | -7.00 | 329 | 15.01 | 339 | 1674 | 7.58 / 159.64 | 6 | 136 |
Average= | 6.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 57 | 14.97 | 509 | 434 | 0.43 / 145.16 | 6 | 65 |
2 | 3 | 1022.00 | 1 | 15.09 | 1783 | 27 | 0.46 / 145.19 | 6 | 6 |
3 | 7 | 2008.96 | 40 | 14.78 | 2919 | 1726 | 2.19 / 146.91 | 6 | 52 |
4 | 13 | 1983.48 | 20 | 14.74 | 2934 | 865 | 3.05 / 147.78 | 6 | 56 |
5 | 13 | 1912.28 | 20 | 14.69 | 2825 | 830 | 3.88 / 148.61 | 6 | 59 |
6 | 13 | 1818.24 | 20 | 14.65 | 2711 | 794 | 4.68 / 149.40 | 6 | 60 |
7 | 13 | 934.48 | 20 | 14.87 | 1579 | 470 | 5.15 / 149.87 | 6 | 73 |
8 | 13 | 518.12 | 20 | 14.97 | 1045 | 313 | 5.46 / 150.18 | 6 | 83 |
9 | 8 | -3.20 | 371 | 15.04 | 335 | 1869 | 7.33 / 152.05 | 6 | 131 |
Average= | 6.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 55 | 14.98 | 494 | 407 | 0.41 / 137.79 | 6 | 62 |
2 | 10 | 1017.84 | 3 | 14.99 | 1700 | 76 | 0.48 / 137.87 | 6 | 50 |
3 | 7 | 2024.36 | 40 | 14.77 | 2972 | 1756 | 2.24 / 139.62 | 50 | 53 |
4 | 13 | 2005.28 | 20 | 14.73 | 2955 | 871 | 3.11 / 140.49 | 6 | 54 |
5 | 13 | 1930.44 | 20 | 14.69 | 2839 | 834 | 3.94 / 141.33 | 6 | 57 |
6 | 13 | 1622.40 | 20 | 14.72 | 2442 | 719 | 4.66 / 142.05 | 6 | 62 |
7 | 13 | 986.68 | 20 | 14.87 | 1619 | 481 | 5.14 / 142.53 | 6 | 72 |
8 | 13 | 368.92 | 20 | 15.02 | 850 | 255 | 5.40 / 142.78 | 6 | 80 |
9 | 13 | 17.40 | 20 | 15.12 | 388 | 117 | 5.52 / 142.90 | 6 | 65 |
10 | 8 | -6.92 | 360 | 15.04 | 337 | 1825 | 7.34 / 144.73 | 6 | 131 |
Average= | 6.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.92 | 56 | 14.98 | 522 | 438 | 0.44 / 130.55 | 6 | 64 |
2 | 3 | 958.92 | -1 | 15.43 | 4 | 0 | 0.00 / 130.55 | 6 | 64 |
3 | 7 | 2023.72 | 40 | 14.78 | 2938 | 1737 | 2.17 / 132.29 | 64 | 53 |
4 | 13 | 1990.56 | 20 | 14.75 | 2921 | 862 | 3.04 / 133.15 | 6 | 57 |
5 | 13 | 1909.64 | 20 | 14.70 | 2819 | 829 | 3.87 / 133.98 | 6 | 58 |
6 | 13 | 1718.32 | 20 | 14.70 | 2566 | 754 | 4.62 / 134.73 | 6 | 60 |
7 | 13 | 1083.68 | 20 | 14.84 | 1759 | 522 | 5.14 / 135.25 | 6 | 71 |
8 | 13 | 425.16 | 20 | 15.01 | 926 | 278 | 5.42 / 135.53 | 6 | 80 |
9 | 8 | -6.60 | 372 | 15.05 | 331 | 1853 | 7.27 / 137.38 | 6 | 132 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 54 | 14.99 | 509 | 412 | 0.41 / 123.12 | 6 | 60 |
2 | 10 | 1026.84 | 3 | 15.00 | 1715 | 77 | 0.49 / 123.20 | 6 | 46 |
3 | 7 | 2020.24 | 40 | 14.78 | 2936 | 1736 | 2.22 / 124.93 | 46 | 54 |
4 | 13 | 1986.04 | 20 | 14.75 | 2897 | 855 | 3.08 / 125.79 | 6 | 54 |
5 | 13 | 1905.84 | 20 | 14.71 | 2813 | 828 | 3.91 / 126.61 | 6 | 58 |
6 | 13 | 1708.20 | 20 | 14.70 | 2574 | 757 | 4.66 / 127.37 | 6 | 60 |
7 | 13 | 1074.16 | 20 | 14.84 | 1752 | 520 | 5.18 / 127.89 | 6 | 70 |
8 | 13 | 535.96 | 20 | 14.98 | 1061 | 318 | 5.50 / 128.21 | 6 | 79 |
9 | 13 | 44.52 | 20 | 15.12 | 423 | 128 | 5.63 / 128.34 | 6 | 72 |
10 | 8 | -5.00 | 351 | 15.05 | 336 | 1775 | 7.40 / 130.11 | 6 | 136 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 45 | 15.01 | 497 | 336 | 0.34 / 115.48 | 6 | 57 |
2 | 10 | 1012.96 | 5 | 14.98 | 1682 | 126 | 0.46 / 115.60 | 6 | 59 |
3 | 10 | 1045.68 | 3 | 14.97 | 1769 | 79 | 0.54 / 115.68 | 6 | 49 |
4 | 3 | 1120.84 | 3 | 15.00 | 1875 | 84 | 0.63 / 115.77 | 6 | 51 |
5 | 7 | 2006.08 | 40 | 14.78 | 2950 | 1744 | 2.37 / 117.51 | 51 | 53 |
6 | 13 | 1990.60 | 20 | 14.74 | 2955 | 871 | 3.24 / 118.38 | 6 | 53 |
7 | 13 | 1922.92 | 20 | 14.71 | 2818 | 829 | 4.07 / 119.21 | 6 | 56 |
8 | 13 | 1727.04 | 20 | 14.70 | 2609 | 767 | 4.84 / 119.98 | 6 | 62 |
9 | 13 | 1177.08 | 20 | 14.81 | 1901 | 563 | 5.40 / 120.54 | 6 | 69 |
10 | 13 | 404.68 | 20 | 15.02 | 906 | 272 | 5.67 / 120.81 | 6 | 80 |
11 | 13 | 38.68 | 20 | 15.13 | 419 | 127 | 5.80 / 120.94 | 6 | 77 |
12 | 8 | -3.16 | 349 | 15.05 | 336 | 1765 | 7.56 / 122.71 | 6 | 138 |
Average= | 6.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 58 | 15.01 | 498 | 434 | 0.43 / 108.55 | 6 | 66 |
2 | 3 | 588.96 | -6 | 15.44 | 3 | 0 | 0.00 / 108.55 | 6 | 66 |
3 | 7 | 2007.64 | 40 | 14.79 | 2914 | 1724 | 2.16 / 110.28 | 66 | 54 |
4 | 13 | 1984.48 | 20 | 14.76 | 2916 | 861 | 3.02 / 111.14 | 6 | 57 |
5 | 13 | 1910.80 | 20 | 14.72 | 2806 | 826 | 3.84 / 111.96 | 6 | 57 |
6 | 13 | 1512.36 | 20 | 14.76 | 2310 | 682 | 4.53 / 112.65 | 6 | 65 |
7 | 13 | 981.20 | 20 | 14.88 | 1635 | 487 | 5.01 / 113.13 | 6 | 72 |
8 | 13 | 339.80 | 20 | 15.05 | 814 | 245 | 5.26 / 113.38 | 6 | 82 |
9 | 8 | -4.40 | 353 | 15.07 | 332 | 1766 | 7.02 / 115.14 | 6 | 132 |
Average= | 6.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 50 | 15.00 | 488 | 366 | 0.37 / 101.29 | 6 | 64 |
2 | 10 | 1035.00 | 5 | 14.95 | 1756 | 131 | 0.50 / 101.42 | 6 | 63 |
3 | 3 | 1134.96 | 3 | 15.00 | 1890 | 85 | 0.58 / 101.50 | 6 | 57 |
4 | 7 | 2013.52 | 40 | 14.79 | 2960 | 1751 | 2.33 / 103.25 | 57 | 52 |
5 | 13 | 1981.92 | 20 | 14.76 | 2956 | 873 | 3.21 / 104.13 | 6 | 57 |
6 | 13 | 1904.00 | 20 | 14.72 | 2848 | 838 | 4.04 / 104.96 | 6 | 56 |
7 | 13 | 1713.68 | 20 | 14.71 | 2583 | 760 | 4.80 / 105.72 | 6 | 63 |
8 | 13 | 955.08 | 20 | 14.89 | 1611 | 480 | 5.28 / 106.20 | 6 | 73 |
9 | 13 | 340.00 | 20 | 15.05 | 832 | 250 | 5.53 / 106.45 | 6 | 82 |
10 | 13 | 29.84 | 20 | 15.14 | 411 | 124 | 5.66 / 106.58 | 6 | 78 |
11 | 8 | -6.32 | 306 | 15.07 | 334 | 1540 | 7.20 / 108.12 | 6 | 131 |
Average= | 6.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 50 | 15.01 | 484 | 363 | 0.36 / 94.05 | 6 | 62 |
2 | 7 | 2007.56 | 40 | 14.79 | 2944 | 1742 | 2.10 / 95.79 | 62 | 54 |
3 | 13 | 1973.32 | 20 | 14.76 | 2919 | 862 | 2.97 / 96.65 | 6 | 59 |
4 | 13 | 1895.36 | 20 | 14.72 | 2832 | 834 | 3.80 / 97.49 | 6 | 59 |
5 | 13 | 1696.60 | 20 | 14.73 | 2532 | 746 | 4.55 / 98.23 | 5 | 63 |
6 | 13 | 1036.48 | 20 | 14.87 | 1708 | 508 | 5.05 / 98.74 | 6 | 72 |
7 | 13 | 387.88 | 20 | 15.04 | 882 | 265 | 5.32 / 99.00 | 6 | 81 |
8 | 8 | -6.72 | 374 | 15.06 | 340 | 1915 | 7.23 / 100.92 | 6 | 130 |
Average= | 5.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 49 | 15.00 | 517 | 380 | 0.38 / 86.64 | 6 | 65 |
2 | 10 | 1023.28 | 3 | 15.01 | 1737 | 78 | 0.46 / 86.72 | 6 | 48 |
3 | 3 | 963.00 | -1 | 15.44 | 3 | 0 | 0.08 / 86.72 | 6 | 48 |
4 | 7 | 2017.72 | 40 | 14.79 | 2962 | 1752 | 2.21 / 88.47 | 48 | 53 |
5 | 13 | 1979.80 | 20 | 14.76 | 2942 | 868 | 3.08 / 89.34 | 6 | 57 |
6 | 13 | 1898.28 | 20 | 14.73 | 2834 | 835 | 3.91 / 90.17 | 6 | 59 |
7 | 13 | 1696.76 | 20 | 14.72 | 2584 | 761 | 4.67 / 90.93 | 6 | 65 |
8 | 13 | 1067.12 | 20 | 14.86 | 1760 | 523 | 5.20 / 91.46 | 6 | 72 |
9 | 13 | 414.84 | 20 | 15.03 | 931 | 280 | 5.48 / 91.74 | 6 | 82 |
10 | 13 | 41.28 | 20 | 15.14 | 434 | 131 | 5.61 / 91.87 | 6 | 69 |
11 | 8 | -5.28 | 353 | 15.06 | 342 | 1818 | 7.43 / 93.69 | 6 | 130 |
Average= | 5.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 51 | 15.00 | 527 | 403 | 0.40 / 79.22 | 6 | 67 |
2 | 3 | 930.04 | -1 | 15.45 | 3 | 0 | 0.00 / 79.22 | 6 | 67 |
3 | 7 | 2005.80 | 41 | 14.79 | 2971 | 1802 | 2.20 / 81.02 | 67 | 54 |
4 | 13 | 1972.24 | 20 | 14.77 | 2946 | 870 | 3.07 / 81.89 | 6 | 57 |
5 | 13 | 1888.64 | 20 | 14.71 | 2846 | 837 | 3.91 / 82.73 | 6 | 58 |
6 | 13 | 1593.40 | 20 | 14.75 | 2452 | 723 | 4.64 / 83.45 | 6 | 64 |
7 | 13 | 1069.92 | 20 | 14.86 | 1766 | 525 | 5.16 / 83.98 | 6 | 71 |
8 | 13 | 423.72 | 20 | 15.03 | 961 | 289 | 5.45 / 84.26 | 6 | 83 |
9 | 8 | -6.40 | 375 | 15.06 | 353 | 1994 | 7.44 / 86.26 | 6 | 129 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 45 | 15.07 | 437 | 296 | 0.30 / 71.76 | 6 | 61 |
2 | 10 | 1012.72 | 3 | 15.02 | 1669 | 75 | 0.37 / 71.84 | 6 | 56 |
3 | 3 | 1144.12 | 4 | 15.02 | 1852 | 111 | 0.48 / 71.95 | 6 | 58 |
4 | 7 | 2020.88 | 41 | 14.81 | 2922 | 1774 | 2.26 / 73.72 | 58 | 55 |
5 | 13 | 1983.16 | 20 | 14.78 | 2880 | 851 | 3.11 / 74.57 | 6 | 58 |
6 | 13 | 1900.04 | 20 | 14.75 | 2753 | 812 | 3.92 / 75.38 | 5 | 57 |
7 | 13 | 1695.88 | 20 | 14.74 | 2508 | 739 | 4.66 / 76.12 | 6 | 66 |
8 | 13 | 1025.20 | 20 | 14.90 | 1633 | 487 | 5.15 / 76.61 | 6 | 71 |
9 | 13 | 465.96 | 20 | 15.04 | 933 | 281 | 5.43 / 76.89 | 6 | 83 |
10 | 8 | -6.64 | 372 | 15.08 | 343 | 1924 | 7.35 / 78.82 | 6 | 129 |
Average= | 5.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 50 | 15.06 | 442 | 333 | 0.33 / 65.01 | 6 | 63 |
2 | 3 | 831.68 | -3 | 15.46 | 3 | 0 | 0.00 / 65.01 | 6 | 63 |
3 | 7 | 2006.04 | 40 | 14.83 | 2881 | 1709 | 2.04 / 66.71 | 63 | 55 |
4 | 13 | 1974.84 | 20 | 14.80 | 2828 | 837 | 2.88 / 67.55 | 6 | 58 |
5 | 13 | 1901.16 | 20 | 14.75 | 2778 | 820 | 3.70 / 68.37 | 6 | 61 |
6 | 13 | 1809.56 | 20 | 14.72 | 2654 | 781 | 4.48 / 69.15 | 6 | 63 |
7 | 13 | 942.76 | 20 | 14.93 | 1522 | 454 | 4.93 / 69.61 | 6 | 74 |
8 | 13 | 323.36 | 20 | 15.09 | 743 | 224 | 5.16 / 69.83 | 6 | 83 |
9 | 13 | 42.08 | 20 | 15.17 | 367 | 111 | 5.27 / 69.94 | 6 | 70 |
10 | 8 | -5.12 | 366 | 15.11 | 275 | 1521 | 6.79 / 71.46 | 6 | 132 |
Average= | 5.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 49 | 15.08 | 447 | 330 | 0.33 / 58.20 | 6 | 57 |
2 | 3 | 1048.24 | 1 | 15.10 | 1769 | 27 | 0.36 / 58.22 | 6 | 21 |
3 | 7 | 2025.12 | 40 | 14.82 | 2906 | 1723 | 2.08 / 59.95 | 21 | 53 |
4 | 13 | 2002.64 | 20 | 14.80 | 2873 | 850 | 2.93 / 60.80 | 6 | 57 |
5 | 13 | 1929.28 | 20 | 14.76 | 2784 | 822 | 3.75 / 61.62 | 6 | 57 |
6 | 13 | 1633.16 | 20 | 14.78 | 2397 | 709 | 4.46 / 62.33 | 6 | 63 |
7 | 13 | 1105.40 | 20 | 14.88 | 1738 | 517 | 4.98 / 62.84 | 6 | 71 |
8 | 13 | 331.56 | 20 | 15.09 | 765 | 231 | 5.21 / 63.07 | 6 | 84 |
9 | 8 | -6.80 | 383 | 15.12 | 276 | 1598 | 6.81 / 64.67 | 6 | 130 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 49 | 15.08 | 445 | 329 | 0.33 / 51.56 | 6 | 54 |
2 | 7 | 2007.12 | 40 | 14.82 | 2889 | 1713 | 2.04 / 53.27 | 54 | 54 |
3 | 13 | 1976.68 | 20 | 14.80 | 2851 | 844 | 2.89 / 54.11 | 6 | 57 |
4 | 13 | 1895.88 | 20 | 14.76 | 2773 | 819 | 3.70 / 54.93 | 6 | 60 |
5 | 13 | 1484.40 | 20 | 14.82 | 2229 | 661 | 4.36 / 55.59 | 6 | 65 |
6 | 13 | 1175.16 | 20 | 14.86 | 1823 | 542 | 4.91 / 56.14 | 6 | 70 |
7 | 13 | 309.92 | 20 | 15.10 | 733 | 221 | 5.13 / 56.36 | 6 | 85 |
8 | 13 | 20.00 | 20 | 15.18 | 340 | 103 | 5.23 / 56.46 | 6 | 78 |
9 | 8 | -6.44 | 343 | 15.13 | 271 | 1406 | 6.64 / 57.87 | 6 | 134 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 52 | 15.09 | 442 | 347 | 0.35 / 45.01 | 6 | 54 |
2 | 3 | 915.12 | -1 | 15.48 | 3 | 0 | 0.00 / 45.01 | 6 | 54 |
3 | 7 | 2023.00 | 40 | 14.82 | 2919 | 1730 | 2.08 / 46.74 | 54 | 54 |
4 | 13 | 1983.64 | 20 | 14.80 | 2890 | 855 | 2.93 / 47.59 | 6 | 58 |
5 | 13 | 1900.16 | 20 | 14.76 | 2787 | 823 | 3.76 / 48.41 | 6 | 61 |
6 | 13 | 1594.12 | 20 | 14.79 | 2374 | 702 | 4.46 / 49.12 | 6 | 65 |
7 | 13 | 947.76 | 20 | 14.93 | 1548 | 462 | 4.92 / 49.58 | 6 | 74 |
8 | 13 | 205.44 | 20 | 15.14 | 597 | 181 | 5.10 / 49.76 | 6 | 82 |
9 | 13 | 18.72 | 20 | 15.19 | 343 | 104 | 5.20 / 49.86 | 6 | 77 |
10 | 8 | -6.52 | 328 | 15.13 | 275 | 1365 | 6.57 / 51.23 | 6 | 132 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 51 | 15.09 | 454 | 349 | 0.35 / 38.30 | 6 | 53 |
2 | 3 | 1032.92 | 1 | 15.14 | 1763 | 27 | 0.38 / 38.32 | 6 | 12 |
3 | 7 | 2007.20 | 40 | 14.84 | 2895 | 1718 | 2.09 / 40.04 | 12 | 55 |
4 | 13 | 1978.12 | 20 | 14.81 | 2889 | 856 | 2.95 / 40.90 | 6 | 55 |
5 | 13 | 1899.68 | 20 | 14.77 | 2790 | 824 | 3.77 / 41.72 | 6 | 60 |
6 | 13 | 1592.08 | 20 | 14.79 | 2394 | 708 | 4.48 / 42.43 | 6 | 66 |
7 | 13 | 1047.08 | 20 | 14.91 | 1683 | 502 | 4.98 / 42.93 | 6 | 75 |
8 | 13 | 381.20 | 20 | 15.08 | 833 | 251 | 5.24 / 43.18 | 6 | 85 |
9 | 13 | 34.20 | 20 | 15.18 | 361 | 110 | 5.35 / 43.29 | 6 | 79 |
10 | 8 | -6.64 | 317 | 15.13 | 285 | 1367 | 6.71 / 44.66 | 6 | 129 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 51 | 15.16 | 463 | 358 | 0.36 / 31.71 | 6 | 53 |
2 | 7 | 2021.32 | 40 | 14.84 | 2917 | 1732 | 2.09 / 33.44 | 53 | 54 |
3 | 13 | 1992.24 | 20 | 14.81 | 2919 | 865 | 2.95 / 34.30 | 6 | 58 |
4 | 13 | 1912.36 | 20 | 14.77 | 2800 | 827 | 3.78 / 35.13 | 6 | 59 |
5 | 13 | 1605.40 | 20 | 14.78 | 2432 | 719 | 4.50 / 35.85 | 6 | 64 |
6 | 13 | 946.36 | 20 | 14.93 | 1574 | 470 | 4.97 / 36.32 | 6 | 77 |
7 | 13 | 406.32 | 20 | 15.07 | 877 | 264 | 5.23 / 36.58 | 6 | 86 |
8 | 13 | 18.60 | 20 | 15.18 | 347 | 105 | 5.34 / 36.69 | 6 | 77 |
9 | 8 | -6.44 | 289 | 15.13 | 288 | 1259 | 6.60 / 37.95 | 6 | 133 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 51 | 15.10 | 453 | 349 | 0.35 / 28.00 | 6 | 50 |
2 | 3 | 1023.44 | 1 | 15.15 | 1795 | 27 | 0.38 / 28.03 | 6 | 8 |
3 | 7 | 1361.64 | 40 | 15.06 | 2094 | 1261 | 1.64 / 29.29 | 8 | 70 |
4 | 13 | 854.88 | 20 | 15.12 | 1461 | 442 | 2.08 / 29.73 | 6 | 78 |
5 | 13 | 222.80 | 20 | 15.24 | 649 | 198 | 2.28 / 29.93 | 6 | 88 |
6 | 13 | 23.64 | 20 | 15.28 | 361 | 110 | 2.39 / 30.04 | 6 | 79 |
7 | 8 | -6.56 | 287 | 15.22 | 299 | 1306 | 3.69 / 31.35 | 6 | 129 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 31 | 15.12 | 453 | 212 | 0.21 / 20.80 | 6 | 50 |
2 | 10 | 1102.76 | 8 | 14.99 | 1801 | 216 | 0.43 / 21.01 | 6 | 61 |
3 | 10 | 1164.40 | 6 | 14.98 | 1884 | 169 | 0.60 / 21.18 | 6 | 61 |
4 | 10 | 1204.16 | 4 | 14.99 | 1921 | 115 | 0.71 / 21.30 | 6 | 57 |
5 | 3 | 1236.88 | 6 | 15.02 | 1962 | 177 | 0.89 / 21.48 | 6 | 66 |
6 | 7 | 2009.24 | 40 | 14.84 | 2930 | 1739 | 2.63 / 23.21 | 66 | 56 |
7 | 13 | 1972.28 | 20 | 14.83 | 2878 | 854 | 3.48 / 24.07 | 6 | 57 |
8 | 13 | 1892.80 | 20 | 14.79 | 2775 | 821 | 4.30 / 24.89 | 6 | 62 |
9 | 13 | 1583.80 | 20 | 14.80 | 2410 | 713 | 5.02 / 25.60 | 6 | 67 |
10 | 13 | 919.96 | 20 | 14.95 | 1554 | 465 | 5.48 / 26.07 | 6 | 76 |
11 | 13 | 187.80 | 20 | 15.15 | 606 | 184 | 5.66 / 26.25 | 6 | 87 |
12 | 13 | 17.84 | 20 | 15.19 | 362 | 110 | 5.77 / 26.36 | 6 | 78 |
13 | 8 | -6.72 | 282 | 15.14 | 303 | 1294 | 7.07 / 27.65 | 6 | 134 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 51 | 15.14 | 464 | 358 | 0.36 / 15.65 | 6 | 54 |
2 | 7 | 1508.96 | 40 | 14.99 | 2291 | 1374 | 1.73 / 17.03 | 6 | 64 |
3 | 13 | 1474.40 | 20 | 14.97 | 2248 | 673 | 2.41 / 17.70 | 6 | 67 |
4 | 13 | 1389.64 | 20 | 14.95 | 2132 | 637 | 3.04 / 18.34 | 6 | 68 |
5 | 13 | 976.56 | 20 | 15.00 | 1602 | 481 | 3.52 / 18.82 | 6 | 76 |
6 | 13 | 321.48 | 20 | 15.14 | 772 | 234 | 3.76 / 19.05 | 6 | 84 |
7 | 13 | 41.88 | 20 | 15.21 | 379 | 115 | 3.87 / 19.17 | 6 | 75 |
8 | 8 | -4.00 | 313 | 15.16 | 299 | 1419 | 5.29 / 20.59 | 6 | 132 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 51 | 15.09 | 446 | 343 | 0.34 / 11.84 | 6 | 50 |
2 | 7 | 1293.08 | 41 | 15.07 | 1993 | 1231 | 1.57 / 13.07 | 50 | 72 |
3 | 13 | 1096.92 | 20 | 15.08 | 1757 | 530 | 2.10 / 13.60 | 6 | 75 |
4 | 13 | 330.64 | 20 | 15.21 | 781 | 238 | 2.34 / 13.84 | 6 | 85 |
5 | 8 | -6.56 | 319 | 15.22 | 300 | 1457 | 3.80 / 15.29 | 6 | 132 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 31 | 15.16 | 441 | 207 | 0.21 / 5.54 | 6 | 46 |
2 | 10 | 1096.64 | 7 | 15.04 | 1757 | 185 | 0.39 / 5.73 | 6 | 61 |
3 | 10 | 1158.12 | 6 | 15.02 | 1828 | 165 | 0.56 / 5.89 | 6 | 61 |
4 | 10 | 1199.32 | 4 | 15.02 | 1900 | 114 | 0.67 / 6.00 | 6 | 58 |
5 | 3 | 1233.24 | 6 | 15.06 | 1941 | 175 | 0.85 / 6.18 | 6 | 67 |
6 | 7 | 1521.56 | 40 | 14.98 | 2293 | 1374 | 2.22 / 7.55 | 67 | 63 |
7 | 13 | 1562.08 | 20 | 14.95 | 2359 | 705 | 2.93 / 8.26 | 6 | 63 |
8 | 13 | 1498.48 | 20 | 14.91 | 2265 | 675 | 3.60 / 8.93 | 6 | 67 |
9 | 13 | 1305.20 | 20 | 14.90 | 2028 | 604 | 4.21 / 9.54 | 6 | 68 |
10 | 13 | 772.08 | 20 | 15.01 | 1333 | 400 | 4.61 / 9.94 | 6 | 78 |
11 | 13 | 62.56 | 20 | 15.20 | 402 | 122 | 4.73 / 10.06 | 6 | 76 |
12 | 13 | 15.20 | 20 | 15.21 | 343 | 104 | 4.83 / 10.17 | 6 | 73 |
13 | 8 | -5.20 | 300 | 15.14 | 293 | 1331 | 6.16 / 11.50 | 6 | 131 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.64 | 31 | 15.39 | 451 | 215 | 0.22 / 1.76 | 6 | 38 |
2 | 10 | 1049.36 | 6 | 15.15 | 1705 | 155 | 0.37 / 1.92 | 6 | 58 |
3 | 10 | 1102.36 | 5 | 15.14 | 1787 | 135 | 0.51 / 2.05 | 6 | 59 |
4 | 3 | 1103.16 | 3 | 15.13 | 1795 | 81 | 0.59 / 2.14 | 6 | 50 |
5 | 7 | 1203.32 | 40 | 15.02 | 1884 | 1132 | 1.72 / 3.27 | 50 | 67 |
6 | 13 | 796.08 | 20 | 15.09 | 1376 | 415 | 2.13 / 3.68 | 6 | 74 |
7 | 13 | 236.16 | 20 | 15.20 | 659 | 200 | 2.33 / 3.88 | 6 | 83 |
8 | 8 | -6.44 | 317 | 15.20 | 301 | 1450 | 3.78 / 5.33 | 6 | 132 |
Average= | 2.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 56.52 | 30 | 15.57 | 346 | 162 | 0.16 / 0.16 | 6 | 23 |
2 | 7 | 68.72 | 40 | 15.54 | 354 | 220 | 0.38 / 0.38 | 23 | 28 |
3 | 13 | 55.32 | 20 | 15.53 | 341 | 106 | 0.49 / 0.49 | 6 | 33 |
4 | 13 | 16.32 | 20 | 15.52 | 291 | 90 | 0.58 / 0.58 | 6 | 39 |
5 | 8 | -6.24 | 258 | 15.48 | 243 | 971 | 1.55 / 1.55 | 6 | 173 |
Average= | 1.55 (KJ/cycle) |