SIO Argo Site:
Pump Diagnostics Page   



Serial= 7488 WMO= 4903043

Return

←PreviousNext→

Cycle 222 GMT 13/11/2024 22:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 32 14.90 453 216 0.22 / 1200.67 6 29
2 7 2012.72 40 14.53 3085 1793 2.01 / 1202.47 29 61
3 13 1984.56 20 14.47 3136 908 2.92 / 1203.37 6 66
4 13 1589.32 20 14.45 2585 747 3.66 / 1204.12 6 75
5 13 925.32 20 14.58 1685 491 4.15 / 1204.61 6 84
6 13 91.92 20 14.88 452 135 4.29 / 1204.75 6 63
7 8 0.12 242 14.87 294 1058 5.35 / 1205.81 6 137
Average= 13.70
(KJ/cycle)

Cycle 221 GMT 4/11/2024 1:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 32 14.90 473 226 0.23 / 1195.28 6 28
2 7 2014.96 40 14.53 3099 1801 2.03 / 1197.08 28 60
3 13 1986.04 20 14.48 3120 904 2.93 / 1197.98 6 65
4 13 1619.44 20 14.45 2609 754 3.68 / 1198.73 6 72
5 13 957.16 20 14.57 1733 505 4.19 / 1199.24 6 84
6 13 133.76 20 14.86 519 154 4.34 / 1199.39 6 65
7 8 0.04 242 14.86 296 1064 5.41 / 1200.46 6 135
Average= 13.80
(KJ/cycle)

Cycle 220 GMT 25/10/2024 4:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 32 14.90 470 224 0.22 / 1189.89 6 26
2 7 2012.48 40 14.54 3085 1794 2.02 / 1191.68 26 60
3 13 1984.92 20 14.48 3132 907 2.93 / 1192.59 6 65
4 13 1462.96 20 14.49 2382 690 3.62 / 1193.28 6 74
5 13 943.08 20 14.57 1708 498 4.11 / 1193.78 6 82
6 13 209.88 20 14.83 644 191 4.30 / 1193.97 6 66
7 13 8.24 20 14.89 314 94 4.40 / 1194.06 6 62
8 8 0.24 225 14.85 295 986 5.38 / 1195.05 6 155
Average= 13.90
(KJ/cycle)

Cycle 219 GMT 15/10/2024 7:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 32 14.90 470 224 0.22 / 1184.52 6 24
2 7 2018.00 40 14.52 3164 1838 2.06 / 1186.36 24 62
3 13 1992.52 20 14.48 3130 906 2.97 / 1187.26 6 65
4 13 1525.16 20 14.47 2480 718 3.69 / 1187.98 6 75
5 13 888.00 20 14.58 1648 481 4.17 / 1188.46 6 83
6 13 89.24 20 14.87 458 136 4.30 / 1188.60 6 64
7 8 0.12 242 14.86 297 1068 5.37 / 1189.67 6 138
Average= 14.00
(KJ/cycle)

Cycle 218 GMT 5/10/2024 10:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 32 14.91 455 217 0.22 / 1179.16 6 24
2 7 2017.12 40 14.55 3086 1796 2.01 / 1180.95 6 61
3 13 1992.00 20 14.50 3074 891 2.90 / 1181.84 6 64
4 13 1484.16 20 14.48 2450 710 3.61 / 1182.55 6 74
5 13 932.16 20 14.57 1695 494 4.11 / 1183.05 6 83
6 13 167.56 20 14.84 571 169 4.28 / 1183.22 6 67
7 13 26.92 20 14.88 347 103 4.38 / 1183.32 6 63
8 8 0.12 223 14.85 295 977 5.36 / 1184.30 6 138
Average= 14.10
(KJ/cycle)

Cycle 217 GMT 25/ 9/2024 13: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 32 14.91 456 218 0.22 / 1173.80 6 19
2 7 2011.92 40 14.54 3150 1832 2.05 / 1175.64 19 62
3 13 1984.52 20 14.48 3127 906 2.96 / 1176.54 6 68
4 13 1443.16 20 14.50 2351 682 3.64 / 1177.22 6 73
5 13 916.20 20 14.58 1676 489 4.13 / 1177.71 6 83
6 13 163.68 20 14.84 569 169 4.29 / 1177.88 6 64
7 8 0.08 242 14.85 294 1057 5.35 / 1178.94 6 136
Average= 14.20
(KJ/cycle)

Cycle 216 GMT 15/ 9/2024 16:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 32 14.91 447 213 0.21 / 1168.47 6 20
2 7 2015.00 40 14.55 3110 1810 2.02 / 1170.28 20 60
3 13 1986.20 20 14.49 3167 918 2.94 / 1171.19 6 66
4 13 1540.64 20 14.48 2515 728 3.67 / 1171.92 6 74
5 13 830.72 20 14.60 1559 455 4.12 / 1172.38 6 85
6 13 79.92 20 14.87 436 130 4.25 / 1172.51 6 64
7 13 21.16 20 14.88 336 100 4.35 / 1172.61 6 65
8 8 -0.04 223 14.85 296 980 5.33 / 1173.59 6 139
Average= 14.31
(KJ/cycle)

Cycle 215 GMT 5/ 9/2024 19: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 32 14.91 445 212 0.21 / 1163.15 6 20
2 7 2013.60 40 14.55 3109 1809 2.02 / 1164.96 6 61
3 13 1985.68 20 14.50 3082 894 2.92 / 1165.86 6 65
4 13 1625.20 20 14.46 2612 755 3.67 / 1166.61 6 72
5 13 793.92 20 14.62 1510 442 4.11 / 1167.05 6 84
6 13 58.32 20 14.88 407 121 4.23 / 1167.17 6 63
7 13 15.76 20 14.89 330 98 4.33 / 1167.27 6 62
8 8 0.04 220 14.84 300 979 5.31 / 1168.25 6 135
Average= 14.42
(KJ/cycle)

Cycle 214 GMT 26/ 8/2024 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 32 14.91 457 218 0.22 / 1157.82 6 20
2 7 2017.28 40 14.53 3177 1846 2.06 / 1159.67 6 61
3 13 1990.60 20 14.49 3125 906 2.97 / 1160.58 6 66
4 13 1481.44 20 14.49 2417 700 3.67 / 1161.28 6 73
5 13 780.56 20 14.62 1500 439 4.11 / 1161.72 6 81
6 13 125.20 20 14.85 517 154 4.26 / 1161.87 6 64
7 13 22.24 20 14.88 344 102 4.37 / 1161.97 6 62
8 8 0.08 220 14.84 297 970 5.33 / 1162.94 6 132
Average= 14.54
(KJ/cycle)

Cycle 213 GMT 17/ 8/2024 1:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 32 14.90 468 223 0.22 / 1152.53 6 21
2 7 2015.36 40 14.55 3085 1795 2.02 / 1154.33 6 59
3 13 1987.12 20 14.51 3072 891 2.91 / 1155.22 6 62
4 13 1416.80 20 14.51 2318 673 3.58 / 1155.89 6 75
5 13 930.72 20 14.57 1692 493 4.08 / 1156.39 6 83
6 13 96.64 20 14.87 457 136 4.21 / 1156.52 6 62
7 13 15.44 20 14.89 325 97 4.31 / 1156.62 6 61
8 8 0.00 226 14.84 294 986 5.29 / 1157.61 6 145
Average= 14.65
(KJ/cycle)

Cycle 212 GMT 7/ 8/2024 4: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 31 14.91 466 215 0.22 / 1147.16 6 22
2 7 2015.60 40 14.55 3104 1807 2.02 / 1148.96 6 60
3 13 1988.48 20 14.48 3135 908 2.93 / 1149.87 6 65
4 13 1542.72 20 14.48 2503 725 3.65 / 1150.60 6 73
5 13 893.04 20 14.59 1646 480 4.13 / 1151.08 6 84
6 13 91.64 20 14.87 460 137 4.27 / 1151.21 6 63
7 13 11.32 20 14.89 325 97 4.37 / 1151.31 6 63
8 8 0.04 223 14.85 302 1000 5.37 / 1152.31 6 135
Average= 14.77
(KJ/cycle)

Cycle 211 GMT 28/ 7/2024 7:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 31 14.91 462 214 0.21 / 1141.87 6 23
2 7 2013.32 40 14.54 3109 1808 2.02 / 1143.68 6 60
3 13 1986.92 20 14.49 3131 907 2.93 / 1144.59 6 65
4 13 1427.44 20 14.50 2331 676 3.61 / 1145.27 6 75
5 13 869.52 20 14.59 1615 471 4.08 / 1145.74 6 83
6 13 66.00 20 14.88 412 123 4.20 / 1145.86 6 63
7 13 12.32 20 14.89 323 96 4.30 / 1145.96 6 64
8 8 0.04 223 14.85 298 987 5.28 / 1146.94 6 140
Average= 14.90
(KJ/cycle)

Cycle 210 GMT 18/ 7/2024 10:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 31 14.91 472 218 0.22 / 1136.46 6 23
2 7 2014.84 40 14.52 3188 1852 2.07 / 1138.31 6 64
3 13 1986.52 20 14.48 3132 907 2.98 / 1139.22 6 66
4 13 1479.16 20 14.48 2419 701 3.68 / 1139.92 6 74
5 13 903.12 20 14.59 1671 488 4.16 / 1140.40 6 84
6 13 126.48 20 14.86 520 155 4.32 / 1140.56 6 66
7 13 21.16 20 14.88 345 103 4.42 / 1140.66 6 65
8 8 0.08 223 14.85 302 1000 5.42 / 1141.66 6 135
Average= 15.02
(KJ/cycle)

Cycle 209 GMT 8/ 7/2024 13:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 31 14.88 469 216 0.22 / 1131.14 6 29
2 7 2017.20 40 14.56 3056 1780 2.00 / 1132.92 6 60
3 13 1991.48 20 14.50 3080 893 2.89 / 1133.81 6 62
4 13 1480.60 20 14.50 2395 695 3.58 / 1134.51 6 73
5 13 912.60 20 14.59 1674 488 4.07 / 1135.00 6 85
6 13 118.16 20 14.86 505 150 4.22 / 1135.15 6 66
7 8 0.00 244 14.86 301 1091 5.31 / 1136.24 6 145
Average= 15.15
(KJ/cycle)

Cycle 208 GMT 28/ 6/2024 16:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 30 14.87 481 215 0.21 / 1125.48 6 27
2 3 1027.40 1 14.97 1853 28 0.24 / 1125.51 6 30
3 7 2013.92 40 14.55 3048 1774 2.02 / 1127.28 30 59
4 13 1986.76 20 14.49 3105 900 2.92 / 1128.18 6 66
5 13 1473.04 20 14.50 2374 688 3.60 / 1128.87 6 73
6 13 1130.36 20 14.53 1914 556 4.16 / 1129.42 6 79
7 13 655.24 20 14.64 1319 386 4.55 / 1129.81 6 89
8 8 0.12 244 14.84 308 1115 5.66 / 1130.92 6 130
Average= 15.28
(KJ/cycle)

Cycle 207 GMT 18/ 6/2024 19:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 32 14.89 464 221 0.22 / 1119.93 6 32
2 3 967.36 -1 14.89 464 0 0.00 / 1119.93 6 32
3 7 2003.92 40 14.54 3147 1830 2.05 / 1121.76 32 62
4 13 1975.52 20 14.48 3148 912 2.96 / 1122.68 6 66
5 13 1422.64 20 14.51 2329 676 3.64 / 1123.35 6 73
6 13 994.92 20 14.56 1769 515 4.15 / 1123.87 6 80
7 13 396.72 20 14.73 951 280 4.43 / 1124.15 6 79
8 8 0.08 242 14.82 311 1115 5.55 / 1125.26 6 132
Average= 15.41
(KJ/cycle)

Cycle 206 GMT 8/ 6/2024 22:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 32 14.89 469 223 0.22 / 1114.47 6 33
2 7 2003.68 40 14.53 3148 1830 2.05 / 1116.30 33 63
3 13 1973.56 20 14.49 3116 903 2.96 / 1117.20 6 67
4 13 1539.88 20 14.48 2511 727 3.68 / 1117.93 6 74
5 13 999.68 20 14.55 1789 521 4.20 / 1118.45 6 84
6 13 144.24 20 14.84 549 163 4.37 / 1118.61 6 69
7 8 0.08 244 14.84 304 1101 5.47 / 1119.71 6 149
Average= 15.55
(KJ/cycle)

Cycle 205 GMT 30/ 5/2024 1:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 32 14.88 486 231 0.23 / 1109.09 6 32
2 7 2012.56 40 14.55 3098 1803 2.03 / 1110.89 6 61
3 13 1985.32 20 14.49 3134 908 2.94 / 1111.80 6 66
4 13 1647.36 20 14.46 2653 767 3.71 / 1112.57 6 71
5 13 876.76 20 14.59 1631 476 4.19 / 1113.04 6 85
6 13 19.72 20 14.89 342 102 4.29 / 1113.15 6 65
7 8 0.12 242 14.85 306 1100 5.39 / 1114.25 6 138
Average= 15.69
(KJ/cycle)

Cycle 204 GMT 20/ 5/2024 4:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 32 14.88 486 231 0.23 / 1103.61 6 39
2 7 2016.48 40 14.55 3088 1797 2.03 / 1105.41 6 61
3 13 1989.28 20 14.50 3091 896 2.93 / 1106.31 6 64
4 13 1668.12 20 14.47 2624 759 3.68 / 1107.07 6 69
5 13 881.72 20 14.60 1639 479 4.16 / 1107.54 6 85
6 13 224.96 20 14.82 678 201 4.36 / 1107.75 6 70
7 8 0.04 244 14.85 307 1112 5.48 / 1108.86 6 141
Average= 15.84
(KJ/cycle)

Cycle 203 GMT 10/ 5/2024 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 32 14.88 491 234 0.23 / 1098.38 6 40
2 7 2005.16 40 14.57 3024 1762 2.00 / 1100.14 6 60
3 13 1978.16 20 14.51 3029 879 2.88 / 1101.02 6 64
4 13 1487.56 20 14.50 2405 697 3.57 / 1101.72 6 74
5 13 855.12 20 14.61 1592 465 4.04 / 1102.18 6 86
6 13 20.88 20 14.90 354 105 4.14 / 1102.29 6 65
7 8 0.20 242 14.85 305 1096 5.24 / 1103.38 6 140
Average= 15.99
(KJ/cycle)

Cycle 202 GMT 30/ 4/2024 10:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 31 14.87 488 225 0.22 / 1092.93 6 41
2 3 1028.44 1 14.96 1859 28 0.25 / 1092.96 6 31
3 7 2014.80 40 14.55 3097 1802 2.06 / 1094.76 31 61
4 13 1985.20 20 14.50 3066 889 2.94 / 1095.65 6 65
5 13 1505.36 20 14.50 2442 708 3.65 / 1096.36 6 73
6 13 899.40 20 14.59 1642 479 4.13 / 1096.84 6 85
7 13 255.24 20 14.81 715 212 4.34 / 1097.05 6 71
8 8 0.00 242 14.84 304 1092 5.44 / 1098.14 6 139
Average= 16.15
(KJ/cycle)

Cycle 201 GMT 20/ 4/2024 13:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 31 14.85 494 227 0.23 / 1087.50 6 41
2 7 2015.24 40 14.57 3031 1766 1.99 / 1089.26 6 59
3 13 1990.20 20 14.50 3120 905 2.90 / 1090.17 6 64
4 13 1632.12 20 14.47 2644 765 3.66 / 1090.93 6 72
5 13 947.12 20 14.57 1733 505 4.17 / 1091.44 6 84
6 13 139.20 20 14.85 548 163 4.33 / 1091.60 6 69
7 8 0.12 242 14.84 308 1106 5.44 / 1092.71 6 133
Average= 16.31
(KJ/cycle)

Cycle 200 GMT 10/ 4/2024 16:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 31 14.86 480 221 0.22 / 1081.91 6 40
2 7 2014.00 40 14.56 3045 1773 1.99 / 1083.68 40 61
3 13 1988.72 20 14.51 3086 896 2.89 / 1084.58 6 65
4 13 1780.84 20 14.45 2783 804 3.69 / 1085.38 6 70
5 13 976.72 20 14.56 1733 505 4.20 / 1085.89 6 82
6 13 322.20 20 14.77 832 246 4.44 / 1086.13 6 79
7 8 0.20 245 14.83 313 1137 5.58 / 1087.27 6 148
Average= 16.47
(KJ/cycle)

Cycle 199 GMT 31/ 3/2024 19:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 30 14.87 488 218 0.22 / 1076.27 6 39
2 3 1036.36 1 14.96 1868 28 0.25 / 1076.30 6 44
3 7 2013.12 40 14.55 3099 1804 2.05 / 1078.10 44 61
4 13 1984.48 20 14.51 3103 900 2.95 / 1079.00 6 63
5 13 1588.16 20 14.49 2541 736 3.69 / 1079.74 6 71
6 13 1040.88 20 14.55 1814 528 4.21 / 1080.27 6 81
7 13 445.52 20 14.72 1025 302 4.52 / 1080.57 6 83
8 8 -0.04 244 14.82 309 1117 5.63 / 1081.69 6 131
Average= 16.64
(KJ/cycle)

Cycle 198 GMT 21/ 3/2024 22:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 32 14.86 497 236 0.24 / 1070.91 6 41
2 3 963.56 -1 14.86 497 0 0.00 / 1070.91 6 41
3 7 2016.84 40 14.56 3089 1799 2.04 / 1072.71 41 60
4 13 1989.84 20 14.50 3148 913 2.95 / 1073.62 6 64
5 13 1577.32 20 14.48 2565 743 3.69 / 1074.36 6 74
6 13 834.04 20 14.61 1561 456 4.15 / 1074.82 6 85
7 13 75.92 20 14.86 446 133 4.28 / 1074.95 6 69
8 8 0.20 242 14.83 307 1102 5.38 / 1076.05 6 132
Average= 16.81
(KJ/cycle)

Cycle 197 GMT 12/ 3/2024 1:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 32 14.86 483 230 0.23 / 1065.46 6 41
2 7 2016.88 40 14.53 3190 1854 2.08 / 1067.31 41 62
3 13 1989.96 20 14.49 3145 911 3.00 / 1068.23 6 65
4 13 1534.96 20 14.49 2494 723 3.72 / 1068.95 6 73
5 13 900.60 20 14.58 1662 485 4.20 / 1069.43 6 84
6 13 116.24 20 14.84 505 150 4.35 / 1069.58 6 72
7 8 -0.12 242 14.82 304 1090 5.44 / 1070.67 6 134
Average= 16.99
(KJ/cycle)

Cycle 196 GMT 2/ 3/2024 5: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 32 14.86 481 229 0.23 / 1060.17 6 41
2 7 2013.32 40 14.56 3100 1805 2.03 / 1061.98 41 60
3 13 1987.36 20 14.51 3045 884 2.92 / 1062.86 6 62
4 13 1363.84 20 14.53 2227 647 3.56 / 1063.51 6 75
5 13 850.72 20 14.60 1583 462 4.03 / 1063.97 6 85
6 13 127.64 20 14.84 521 155 4.18 / 1064.13 6 72
7 8 0.04 244 14.83 305 1104 5.29 / 1065.23 6 142
Average= 17.18
(KJ/cycle)

Cycle 195 GMT 21/ 2/2024 7:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 32 14.84 478 227 0.23 / 1054.82 6 40
2 7 2010.60 40 14.56 3054 1779 2.01 / 1056.60 40 59
3 13 1981.72 20 14.49 3117 903 2.91 / 1057.50 6 66
4 13 1475.08 20 14.49 2408 698 3.61 / 1058.20 6 75
5 13 995.48 20 14.57 1757 512 4.12 / 1058.71 6 82
6 13 76.88 20 14.87 444 132 4.25 / 1058.84 6 70
7 8 0.28 242 14.84 307 1103 5.35 / 1059.94 6 133
Average= 17.38
(KJ/cycle)

Cycle 194 GMT 11/ 2/2024 10:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 32 14.81 486 230 0.23 / 1049.36 6 41
2 7 2015.76 40 14.55 3057 1779 2.01 / 1051.14 41 59
3 13 1991.88 20 14.50 3088 896 2.91 / 1052.04 6 66
4 13 1544.68 20 14.48 2473 716 3.62 / 1052.75 6 73
5 13 969.52 20 14.55 1727 503 4.12 / 1053.26 6 83
6 13 254.28 20 14.77 731 216 4.34 / 1053.47 6 77
7 8 0.08 248 14.81 305 1120 5.46 / 1054.59 6 145
Average= 17.58
(KJ/cycle)

Cycle 193 GMT 1/ 2/2024 13:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 32 14.84 495 235 0.24 / 1043.85 6 38
2 7 2017.36 40 14.55 3096 1802 2.04 / 1045.65 38 59
3 13 1991.40 20 14.49 3099 898 2.94 / 1046.55 6 65
4 13 1495.00 20 14.49 2447 709 3.64 / 1047.26 6 75
5 13 992.72 20 14.54 1789 520 4.16 / 1047.78 6 83
6 13 352.44 20 14.73 860 253 4.42 / 1048.03 6 75
7 8 0.24 244 14.79 304 1097 5.51 / 1049.13 6 139
Average= 17.78
(KJ/cycle)

Cycle 192 GMT 22/ 1/2024 16:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 32 14.83 490 233 0.23 / 1038.38 6 38
2 7 2015.84 40 14.54 3159 1837 2.07 / 1040.21 38 62
3 13 1986.44 20 14.48 3150 912 2.98 / 1041.13 6 66
4 13 1653.36 20 14.45 2681 775 3.76 / 1041.90 6 71
5 13 949.28 20 14.56 1730 504 4.26 / 1042.40 6 82
6 13 26.00 20 14.86 364 108 4.37 / 1042.51 6 64
7 8 0.16 242 14.82 308 1105 5.47 / 1043.62 6 141
Average= 17.99
(KJ/cycle)

Cycle 191 GMT 12/ 1/2024 19:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 32 14.87 487 232 0.23 / 1032.93 6 39
2 7 2004.12 40 14.56 3079 1793 2.02 / 1034.72 39 57
3 13 1978.08 20 14.51 3054 886 2.91 / 1035.61 6 61
4 13 1490.56 20 14.49 2445 709 3.62 / 1036.31 6 72
5 13 1034.28 20 14.53 1842 535 4.16 / 1036.85 6 80
6 13 217.84 20 14.78 670 198 4.35 / 1037.05 6 69
7 8 -0.04 242 14.80 306 1096 5.45 / 1038.14 6 136
Average= 18.21
(KJ/cycle)

Cycle 190 GMT 2/ 1/2024 23: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 31 14.88 487 225 0.22 / 1027.39 6 37
2 3 1025.12 1 14.98 1871 28 0.25 / 1027.42 6 32
3 7 2015.44 40 14.53 3174 1845 2.10 / 1029.26 32 60
4 13 1991.40 20 14.48 3150 912 3.01 / 1030.17 6 62
5 13 1475.04 20 14.49 2428 704 3.71 / 1030.88 6 74
6 13 1014.96 20 14.55 1823 530 4.24 / 1031.41 6 80
7 13 107.96 20 14.85 509 151 4.39 / 1031.56 6 70
8 8 0.04 242 14.84 316 1135 5.53 / 1032.69 6 134
Average= 18.44
(KJ/cycle)

Cycle 189 GMT 24/12/2023 2:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 30 14.88 480 214 0.21 / 1022.02 6 37
2 3 1034.52 1 14.96 1888 28 0.24 / 1022.05 6 36
3 7 2003.64 40 14.54 3084 1794 2.04 / 1023.84 36 63
4 13 1977.04 20 14.49 3120 904 2.94 / 1024.75 6 66
5 13 1418.16 20 14.50 2332 676 3.62 / 1025.42 6 75
6 13 965.16 20 14.57 1739 507 4.12 / 1025.93 6 85
7 13 87.32 20 14.87 462 137 4.26 / 1026.07 6 68
8 8 -0.04 242 14.85 305 1096 5.36 / 1027.16 6 134
Average= 18.68
(KJ/cycle)

Cycle 188 GMT 14/12/2023 5:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 32 14.87 470 224 0.22 / 1016.59 6 34
2 3 948.76 -1 14.87 470 0 0.00 / 1016.59 6 34
3 7 2011.84 40 14.54 3089 1797 2.02 / 1018.39 34 62
4 13 1980.16 20 14.49 3101 899 2.92 / 1019.29 6 68
5 13 1639.64 20 14.46 2653 767 3.69 / 1020.06 6 75
6 13 836.40 20 14.61 1562 456 4.14 / 1020.51 6 85
7 13 188.72 20 14.83 621 184 4.33 / 1020.70 6 79
8 8 0.20 242 14.84 309 1110 5.44 / 1021.81 6 132
Average= 18.92
(KJ/cycle)

Cycle 187 GMT 4/12/2023 8:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 30 14.86 469 209 0.21 / 1011.14 6 36
2 10 1003.84 3 14.88 1804 81 0.29 / 1011.22 6 63
3 3 915.16 -1 14.88 1804 0 0.08 / 1011.22 6 63
4 7 2013.68 40 14.55 3039 1769 2.06 / 1012.99 63 62
5 13 1989.16 20 14.50 3043 882 2.94 / 1013.88 6 64
6 13 1490.92 20 14.49 2414 700 3.64 / 1014.57 6 77
7 13 821.80 20 14.62 1514 443 4.08 / 1015.02 6 86
8 13 290.32 20 14.78 781 231 4.31 / 1015.25 6 86
9 8 0.04 245 14.83 309 1123 5.44 / 1016.37 6 133
Average= 19.18
(KJ/cycle)

Cycle 186 GMT 24/11/2023 11:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 32 14.87 462 220 0.22 / 1005.56 6 33
2 3 963.84 -1 14.87 462 0 0.00 / 1005.56 6 33
3 7 2014.64 40 14.55 3052 1776 2.00 / 1007.34 33 61
4 13 1989.92 20 14.49 3065 888 2.88 / 1008.23 6 64
5 13 1385.20 20 14.51 2251 653 3.54 / 1008.88 6 77
6 13 975.76 20 14.58 1705 497 4.03 / 1009.38 6 82
7 13 656.16 20 14.64 1302 381 4.42 / 1009.76 6 89
8 8 0.16 251 14.82 316 1175 5.59 / 1010.93 6 139
Average= 19.44
(KJ/cycle)

Cycle 185 GMT 14/11/2023 14:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 32 14.89 465 222 0.22 / 1000.22 6 26
2 7 2005.60 40 14.54 3033 1764 1.99 / 1001.99 26 61
3 13 1803.12 20 14.50 2855 828 2.81 / 1002.82 6 69
4 13 1548.16 20 14.46 2519 728 3.54 / 1003.54 6 74
5 13 997.00 20 14.53 1764 513 4.05 / 1004.06 6 84
6 13 146.04 20 14.82 555 165 4.22 / 1004.22 6 76
7 8 -0.08 246 14.81 308 1122 5.34 / 1005.34 6 141
Average= 19.71
(KJ/cycle)

Cycle 184 GMT 4/11/2023 17:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 32 14.91 460 219 0.22 / 994.83 6 28
2 7 2003.76 40 14.55 3041 1770 1.99 / 996.60 28 61
3 13 1978.80 20 14.48 3071 889 2.88 / 997.49 6 64
4 13 1608.36 20 14.46 2568 743 3.62 / 998.23 6 74
5 13 851.12 20 14.59 1591 464 4.09 / 998.70 6 85
6 13 252.60 20 14.79 711 210 4.30 / 998.91 6 67
7 8 0.12 244 14.83 302 1093 5.39 / 1000.00 6 137
Average= 20.00
(KJ/cycle)

Cycle 183 GMT 25/10/2023 20:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 31 14.89 483 223 0.22 / 989.40 6 26
2 3 1030.52 1 14.99 1851 28 0.25 / 989.43 6 37
3 7 2013.12 40 14.54 3068 1784 2.04 / 991.22 37 61
4 13 1985.72 20 14.47 3154 913 2.95 / 992.13 6 69
5 13 1543.48 20 14.47 2498 723 3.67 / 992.85 6 75
6 13 856.44 20 14.59 1583 462 4.13 / 993.31 6 82
7 13 222.96 20 14.81 674 200 4.33 / 993.51 6 74
8 8 0.24 242 14.84 306 1099 5.43 / 994.61 6 132
Average= 20.30
(KJ/cycle)

Cycle 182 GMT 15/10/2023 23:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 31 14.90 476 220 0.22 / 983.85 6 24
2 7 2013.60 40 14.54 3042 1769 1.99 / 985.62 24 61
3 13 1984.20 20 14.49 3074 891 2.88 / 986.51 6 66
4 13 1592.12 20 14.47 2539 735 3.61 / 987.24 6 72
5 13 1047.28 20 14.54 1802 524 4.14 / 987.77 6 83
6 13 415.08 20 14.74 981 289 4.43 / 988.05 6 81
7 8 0.04 246 14.83 309 1127 5.56 / 989.18 6 141
Average= 20.61
(KJ/cycle)

Cycle 181 GMT 6/10/2023 3: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 30 14.90 480 215 0.21 / 978.18 6 23
2 7 2014.24 40 14.53 3109 1807 2.02 / 979.99 6 64
3 13 1986.00 20 14.48 3111 901 2.92 / 980.89 6 68
4 13 1631.08 20 14.47 2581 747 3.67 / 981.63 6 72
5 13 780.84 20 14.63 1471 430 4.10 / 982.06 6 88
6 13 713.24 20 14.62 1385 405 4.50 / 982.47 6 89
7 13 33.56 20 14.86 379 113 4.62 / 982.58 6 71
8 8 0.16 225 14.83 313 1044 5.66 / 983.63 6 138
Average= 20.93
(KJ/cycle)

Cycle 180 GMT 26/ 9/2023 6:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 32 14.85 474 225 0.23 / 972.62 6 29
2 3 938.96 -1 14.85 474 0 0.00 / 972.62 6 29
3 7 2016.12 41 14.54 3081 1837 2.06 / 974.46 29 62
4 13 1988.96 20 14.49 3042 882 2.94 / 975.34 6 66
5 13 1747.28 20 14.45 2725 788 3.73 / 976.13 6 72
6 13 836.24 20 14.62 1523 445 4.18 / 976.57 6 85
7 13 288.80 20 14.79 791 234 4.41 / 976.81 6 92
8 13 23.56 20 14.88 357 106 4.52 / 976.91 6 81
9 8 0.00 225 14.83 315 1051 5.57 / 977.96 6 141
Average= 21.26
(KJ/cycle)

Cycle 179 GMT 16/ 9/2023 9:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 32 14.89 464 221 0.22 / 967.16 6 27
2 7 2012.08 40 14.52 3068 1782 2.00 / 968.94 27 65
3 13 1985.12 20 14.48 3028 877 2.88 / 969.82 6 69
4 13 1557.80 20 14.46 2483 718 3.60 / 970.54 6 74
5 13 757.76 20 14.62 1424 416 4.01 / 970.95 6 86
6 13 231.28 20 14.77 710 210 4.22 / 971.16 6 93
7 13 18.24 20 14.84 365 108 4.33 / 971.27 6 91
8 8 0.00 233 14.79 327 1127 5.46 / 972.40 6 137
Average= 21.61
(KJ/cycle)

Cycle 178 GMT 6/ 9/2023 12: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 32 14.88 454 216 0.22 / 961.74 6 24
2 7 2015.08 40 14.54 3037 1766 1.98 / 963.50 24 60
3 13 1989.40 20 14.47 3154 913 2.90 / 964.41 6 66
4 13 1482.64 20 14.48 2413 699 3.59 / 965.11 6 74
5 13 980.68 20 14.56 1741 507 4.10 / 965.62 6 82
6 13 260.64 20 14.80 732 217 4.32 / 965.84 6 78
7 8 0.08 244 14.84 304 1101 5.42 / 966.94 6 136
Average= 21.98
(KJ/cycle)

Cycle 177 GMT 27/ 8/2023 15: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 32 14.89 475 226 0.23 / 956.25 6 20
2 7 2013.20 40 14.52 3108 1805 2.03 / 958.05 20 63
3 13 1984.92 20 14.49 3059 886 2.92 / 958.94 6 68
4 13 1574.32 20 14.46 2534 733 3.65 / 959.67 6 72
5 13 950.36 20 14.56 1682 490 4.14 / 960.16 6 81
6 13 303.32 20 14.76 787 232 4.37 / 960.39 6 75
7 13 22.64 20 14.86 345 103 4.48 / 960.50 6 67
8 8 0.04 225 14.81 307 1023 5.50 / 961.52 6 137
Average= 22.36
(KJ/cycle)

Cycle 176 GMT 17/ 8/2023 18: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 32 14.88 466 222 0.22 / 950.65 6 25
2 3 1022.84 1 14.99 1874 28 0.25 / 950.68 6 28
3 7 2014.44 40 14.53 3109 1807 2.06 / 952.48 28 61
4 13 1986.72 20 14.50 3033 880 2.94 / 953.36 6 64
5 13 1508.12 20 14.48 2444 708 3.64 / 954.07 6 74
6 13 1050.76 20 14.53 1826 531 4.17 / 954.60 6 79
7 13 405.64 20 14.73 958 282 4.46 / 954.88 6 77
8 13 30.92 20 14.85 368 109 4.57 / 954.99 6 66
9 8 0.20 225 14.82 308 1027 5.59 / 956.02 6 137
Average= 22.76
(KJ/cycle)

Cycle 175 GMT 7/ 8/2023 21:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 31 14.90 469 217 0.22 / 945.13 6 23
2 3 1020.20 1 15.01 1864 28 0.24 / 945.16 6 28
3 7 2015.24 41 14.52 3101 1846 2.09 / 947.01 28 64
4 13 1987.56 20 14.47 3083 892 2.98 / 947.90 6 66
5 13 1602.00 20 14.45 2571 743 3.73 / 948.64 6 75
6 13 848.16 20 14.58 1563 456 4.18 / 949.10 6 86
7 13 260.04 20 14.77 735 217 4.40 / 949.31 6 79
8 8 -0.04 244 14.81 308 1113 5.51 / 950.43 6 141
Average= 23.18
(KJ/cycle)

Cycle 174 GMT 29/ 7/2023 0:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 31 14.88 482 222 0.22 / 939.72 6 24
2 7 2012.64 40 14.55 3052 1776 2.00 / 941.50 24 60
3 13 1982.36 20 14.50 3092 897 2.90 / 942.40 6 65
4 13 1577.28 20 14.47 2543 736 3.63 / 943.13 6 72
5 13 820.84 20 14.61 1552 453 4.08 / 943.59 6 83
6 13 241.28 20 14.81 697 206 4.29 / 943.79 6 68
7 13 12.60 20 14.87 331 98 4.39 / 943.89 6 64
8 8 0.04 223 14.83 310 1025 5.41 / 944.92 6 135
Average= 23.62
(KJ/cycle)

Cycle 173 GMT 19/ 7/2023 3:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 31 14.84 473 218 0.22 / 934.22 6 25
2 7 2019.64 40 14.55 3046 1773 1.99 / 935.99 25 62
3 13 1997.64 20 14.49 3061 887 2.88 / 936.88 6 66
4 13 1472.28 20 14.50 2377 689 3.57 / 937.57 6 75
5 13 954.68 20 14.58 1669 487 4.05 / 938.06 6 79
6 13 371.52 20 14.74 911 269 4.32 / 938.32 6 88
7 13 34.24 20 14.86 377 112 4.43 / 938.44 6 75
8 8 0.20 228 14.82 315 1064 5.50 / 939.50 6 145
Average= 24.09
(KJ/cycle)

Cycle 172 GMT 9/ 7/2023 6:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 31 14.87 485 224 0.22 / 929.02 6 28
2 7 2003.52 40 14.53 3045 1770 1.99 / 930.79 6 63
3 13 1975.00 20 14.50 3008 872 2.87 / 931.66 6 65
4 13 1361.96 20 14.50 2243 650 3.52 / 932.31 6 79
5 13 735.76 20 14.61 1406 411 3.93 / 932.72 6 86
6 13 78.16 20 14.82 454 135 4.06 / 932.86 6 77
7 8 -0.04 244 14.79 317 1144 5.21 / 934.00 6 137
Average= 24.58
(KJ/cycle)

Cycle 171 GMT 29/ 6/2023 9: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 31 14.88 477 220 0.22 / 923.55 6 25
2 7 2012.88 41 14.52 3167 1885 2.11 / 925.44 25 63
3 13 1987.88 20 14.47 3146 910 3.02 / 926.35 6 65
4 13 1482.12 20 14.48 2414 699 3.71 / 927.05 6 73
5 13 868.96 20 14.58 1625 474 4.19 / 927.52 6 86
6 13 110.16 20 14.84 502 149 4.34 / 927.67 6 66
7 8 0.04 242 14.82 314 1126 5.46 / 928.80 6 139
Average= 25.10
(KJ/cycle)

Cycle 170 GMT 19/ 6/2023 12: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 31 14.86 471 217 0.22 / 918.06 6 35
2 7 2012.68 40 14.55 3068 1786 2.00 / 919.85 6 60
3 13 1986.64 20 14.50 3065 889 2.89 / 920.73 6 66
4 13 1573.08 20 14.48 2517 729 3.62 / 921.46 6 72
5 13 995.52 20 14.55 1754 510 4.13 / 921.97 6 82
6 13 258.52 20 14.78 744 220 4.35 / 922.19 6 77
7 8 0.24 244 14.82 315 1139 5.49 / 923.33 6 139
Average= 25.65
(KJ/cycle)

Cycle 169 GMT 9/ 6/2023 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 32 14.84 478 227 0.23 / 912.73 6 33
2 3 959.48 -1 14.84 478 0 0.00 / 912.73 6 33
3 7 2015.72 40 14.54 3068 1784 2.01 / 914.52 33 62
4 13 1989.80 20 14.48 3129 906 2.92 / 915.42 6 68
5 13 1431.88 20 14.50 2359 684 3.60 / 916.11 6 77
6 13 800.80 20 14.61 1512 442 4.04 / 916.55 6 86
7 13 82.16 20 14.84 462 137 4.18 / 916.69 6 79
8 8 0.16 244 14.82 320 1157 5.34 / 917.84 6 133
Average= 26.22
(KJ/cycle)

Cycle 168 GMT 30/ 5/2023 17:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 32 14.85 490 233 0.23 / 907.26 6 36
2 7 2014.72 41 14.54 3054 1821 2.05 / 909.08 36 59
3 13 1987.88 20 14.48 3105 899 2.95 / 909.98 6 66
4 13 1657.76 20 14.44 2662 769 3.72 / 910.75 6 74
5 13 855.72 20 14.57 1572 458 4.18 / 911.20 6 84
6 13 143.68 20 14.81 549 163 4.34 / 911.37 6 75
7 8 -0.08 245 14.80 314 1139 5.48 / 912.51 6 141
Average= 26.84
(KJ/cycle)

Cycle 167 GMT 20/ 5/2023 20:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 32 14.86 490 233 0.23 / 901.81 6 36
2 7 2004.12 40 14.53 3100 1802 2.03 / 903.61 6 60
3 13 1975.28 20 14.48 3135 908 2.94 / 904.52 6 64
4 13 1531.16 20 14.47 2501 724 3.67 / 905.25 6 74
5 13 1060.08 20 14.52 1857 539 4.21 / 905.79 6 80
6 13 9.12 20 14.86 336 100 4.31 / 905.88 6 61
7 8 0.20 242 14.81 318 1140 5.45 / 907.02 6 133
Average= 27.49
(KJ/cycle)

Cycle 166 GMT 10/ 5/2023 23:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 31 14.87 482 222 0.22 / 896.34 6 40
2 3 1034.60 1 15.01 1886 28 0.25 / 896.36 6 40
3 7 2006.16 40 14.54 3166 1841 2.09 / 898.21 40 61
4 13 1978.36 20 14.48 3150 912 3.00 / 899.12 6 66
5 13 1532.56 20 14.49 2487 721 3.72 / 899.84 6 73
6 13 953.96 20 14.56 1744 508 4.23 / 900.35 6 83
7 13 17.32 20 14.86 346 103 4.34 / 900.45 6 62
8 8 0.00 242 14.82 315 1130 5.47 / 901.58 6 132
Average= 28.17
(KJ/cycle)

Cycle 165 GMT 1/ 5/2023 2:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 33 14.81 472 231 0.23 / 890.98 6 36
2 3 939.92 -1 14.81 472 0 0.00 / 890.98 6 36
3 7 2003.68 40 14.52 3161 1836 2.07 / 892.82 36 62
4 13 1976.40 20 14.48 3105 899 2.97 / 893.72 6 66
5 13 1474.84 20 14.49 2399 695 3.66 / 894.41 6 74
6 13 879.60 20 14.59 1632 476 4.14 / 894.89 6 84
7 13 20.84 20 14.88 355 106 4.24 / 895.00 6 68
8 13 9.88 20 14.87 337 100 4.34 / 895.10 6 66
9 8 0.20 220 14.83 312 1018 5.36 / 896.11 6 132
Average= 28.91
(KJ/cycle)

Cycle 164 GMT 21/ 4/2023 6: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 33 14.82 492 241 0.24 / 885.52 6 38
2 7 2012.72 40 14.52 3114 1809 2.05 / 887.33 38 62
3 13 1986.24 20 14.47 3074 890 2.94 / 888.22 6 66
4 13 1625.20 20 14.44 2645 764 3.70 / 888.98 6 74
5 13 943.04 20 14.53 1673 486 4.19 / 889.47 6 82
6 13 137.52 20 14.78 549 162 4.35 / 889.63 6 70
7 8 -0.04 242 14.77 314 1122 5.47 / 890.75 6 131
Average= 29.69
(KJ/cycle)

Cycle 163 GMT 11/ 4/2023 8:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 30 14.90 499 223 0.22 / 879.93 6 38
2 10 1017.00 3 15.00 1847 83 0.31 / 880.01 6 46
3 7 2015.12 40 14.55 3109 1809 2.12 / 881.82 6 58
4 13 1986.28 20 14.49 3141 910 3.03 / 882.73 6 65
5 13 1444.72 20 14.50 2363 685 3.71 / 883.42 6 76
6 13 1070.92 20 14.52 1875 544 4.26 / 883.96 6 81
7 13 238.48 20 14.77 691 204 4.46 / 884.17 6 61
8 8 -0.04 244 14.79 308 1111 5.57 / 885.28 6 144
Average= 30.53
(KJ/cycle)

Cycle 162 GMT 1/ 4/2023 11:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 32 14.85 512 243 0.24 / 874.57 6 46
2 3 967.36 -1 14.85 512 0 0.00 / 874.57 6 46
3 7 2005.28 40 14.59 3083 1799 2.04 / 876.37 46 59
4 13 1979.68 20 14.55 3038 884 2.93 / 877.26 6 63
5 13 1476.04 20 14.54 2384 693 3.62 / 877.95 6 74
6 13 980.44 20 14.59 1766 515 4.14 / 878.47 6 84
7 13 15.36 20 14.91 346 103 4.24 / 878.57 6 62
8 8 0.12 242 14.86 317 1140 5.38 / 879.71 6 132
Average= 31.42
(KJ/cycle)

Cycle 161 GMT 22/ 3/2023 15: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 31 14.80 533 245 0.24 / 869.18 6 63
2 7 2004.32 40 14.58 3052 1780 2.02 / 870.96 6 62
3 13 1904.52 20 14.56 2916 849 2.87 / 871.81 6 66
4 13 1273.88 20 14.56 2127 619 3.49 / 872.43 6 80
5 13 848.96 20 14.63 1551 454 3.95 / 872.88 6 85
6 13 275.68 20 14.79 774 229 4.18 / 873.11 6 91
7 8 0.32 246 14.82 334 1218 5.39 / 874.33 6 130
Average= 32.38
(KJ/cycle)

Cycle 160 GMT 12/ 3/2023 18: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 31 14.82 503 231 0.23 / 863.65 6 38
2 7 2012.52 41 14.55 3076 1835 2.07 / 865.48 38 64
3 13 1983.32 20 14.50 3026 878 2.94 / 866.36 6 66
4 13 1502.16 20 14.52 2395 696 3.64 / 867.05 6 75
5 13 780.12 20 14.63 1438 421 4.06 / 867.47 6 85
6 13 118.72 20 14.83 529 157 4.22 / 867.63 6 91
7 8 0.20 261 14.79 338 1305 5.52 / 868.94 6 140
Average= 33.42
(KJ/cycle)

Cycle 159 GMT 2/ 3/2023 20:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 31 14.85 496 228 0.23 / 858.04 6 36
2 7 2013.68 40 14.54 3073 1787 2.02 / 859.83 36 62
3 13 1986.92 20 14.49 3059 886 2.90 / 860.72 6 64
4 13 1442.88 20 14.50 2328 675 3.58 / 861.39 6 76
5 13 991.92 20 14.55 1744 508 4.08 / 861.90 6 84
6 13 372.08 20 14.71 923 272 4.36 / 862.17 6 93
7 13 55.60 20 14.82 424 126 4.48 / 862.30 6 82
8 13 28.40 20 14.82 380 113 4.59 / 862.41 6 79
9 8 -0.24 209 14.78 326 1007 5.60 / 863.41 6 132
Average= 34.54
(KJ/cycle)

Cycle 158 GMT 20/ 2/2023 23:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 31 14.90 475 219 0.22 / 852.50 6 33
2 3 1022.92 1 15.05 1878 28 0.25 / 852.53 6 17
3 7 2012.16 40 14.55 3108 1809 2.06 / 854.34 17 62
4 13 1984.20 20 14.50 3079 893 2.95 / 855.23 6 63
5 13 1543.00 20 14.50 2462 714 3.66 / 855.94 6 74
6 13 924.08 20 14.56 1700 495 4.16 / 856.44 6 84
7 13 301.72 20 14.75 794 234 4.39 / 856.67 6 73
8 8 0.16 244 14.80 316 1141 5.53 / 857.81 6 138
Average= 35.74
(KJ/cycle)

Cycle 157 GMT 11/ 2/2023 2:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 31 14.86 505 233 0.23 / 847.01 6 41
2 7 2017.16 40 14.57 3115 1815 2.05 / 848.82 6 62
3 13 1992.04 20 14.50 3183 923 2.97 / 849.75 6 66
4 13 1481.28 20 14.52 2396 696 3.67 / 850.44 6 73
5 13 821.36 20 14.63 1545 452 4.12 / 850.90 6 86
6 13 324.36 20 14.79 825 244 4.36 / 851.14 6 71
7 13 1.72 20 14.90 317 94 4.46 / 851.23 6 71
8 8 0.12 225 14.85 313 1046 5.50 / 852.28 6 145
Average= 37.06
(KJ/cycle)

Cycle 156 GMT 1/ 2/2023 5:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 30 14.87 511 228 0.23 / 841.55 6 41
2 7 2004.44 40 14.57 3062 1785 2.01 / 843.34 6 63
3 13 1977.16 20 14.53 3037 883 2.90 / 844.22 6 68
4 13 1545.00 20 14.52 2481 720 3.62 / 844.94 6 76
5 13 850.64 20 14.62 1547 452 4.07 / 845.39 6 86
6 13 212.68 20 14.82 679 201 4.27 / 845.59 6 83
7 8 0.16 244 14.83 327 1183 5.45 / 846.78 6 129
Average= 38.49
(KJ/cycle)

Cycle 155 GMT 22/ 1/2023 8:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 32 14.87 520 247 0.25 / 835.89 6 46
2 3 959.16 -1 14.87 520 0 0.00 / 835.89 6 46
3 7 2004.36 40 14.58 3056 1782 2.03 / 837.67 46 63
4 13 1979.64 20 14.53 3103 902 2.93 / 838.57 6 70
5 13 1774.08 20 14.48 2804 812 3.74 / 839.38 6 72
6 13 982.44 20 14.59 1724 503 4.25 / 839.88 6 85
7 13 287.04 20 14.79 797 236 4.48 / 840.12 6 91
8 8 0.00 246 14.83 330 1204 5.69 / 841.32 6 134
Average= 40.06
(KJ/cycle)

Cycle 154 GMT 12/ 1/2023 11:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 33 14.77 521 254 0.25 / 830.47 6 73
2 3 961.44 -1 14.77 521 0 0.00 / 830.47 6 73
3 7 2005.16 41 14.60 3054 1828 2.08 / 832.30 73 66
4 13 1980.20 20 14.54 3072 893 2.98 / 833.19 6 68
5 13 1286.28 20 14.58 2120 618 3.59 / 833.81 6 80
6 13 721.00 20 14.68 1379 405 4.00 / 834.22 6 89
7 13 130.04 20 14.86 555 165 4.16 / 834.38 6 88
8 8 0.28 254 14.85 333 1256 5.42 / 835.64 6 138
Average= 41.78
(KJ/cycle)

Cycle 153 GMT 2/ 1/2023 14:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 30 14.80 527 234 0.23 / 824.32 6 74
2 10 1001.60 3 14.81 1765 78 0.31 / 824.40 6 71
3 3 1026.68 1 14.92 1837 27 0.34 / 824.42 6 25
4 7 2014.28 40 14.58 3063 1786 2.13 / 826.21 25 66
5 13 1988.96 20 14.54 3042 885 3.01 / 827.10 6 68
6 13 1434.28 20 14.55 2323 676 3.69 / 827.77 6 79
7 13 951.96 20 14.61 1677 490 4.18 / 828.26 6 86
8 13 157.64 20 14.83 588 174 4.35 / 828.44 6 84
9 13 41.92 20 14.86 429 127 4.48 / 828.56 6 81
10 8 -0.24 317 14.79 353 1655 6.13 / 830.22 6 132
Average= 43.70
(KJ/cycle)

Cycle 152 GMT 23/12/2022 17:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 32 14.86 505 240 0.24 / 818.59 6 48
2 3 961.40 -1 14.86 505 0 0.00 / 818.59 6 48
3 7 2014.96 40 14.58 3076 1794 2.03 / 820.38 48 66
4 13 1988.16 20 14.53 3062 890 2.92 / 821.27 6 69
5 13 1401.56 20 14.56 2272 662 3.59 / 821.93 6 80
6 13 1058.68 20 14.57 1832 534 4.12 / 822.47 6 87
7 13 304.56 20 14.77 802 237 4.36 / 822.70 6 92
8 8 0.40 270 14.80 346 1383 5.74 / 824.08 6 136
Average= 45.78
(KJ/cycle)

Cycle 151 GMT 13/12/2022 20:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 31 14.83 523 240 0.24 / 812.98 6 66
2 3 1049.80 1 14.89 1853 28 0.27 / 813.00 6 61
3 7 2015.56 40 14.58 3063 1786 2.05 / 814.79 61 65
4 13 1987.04 20 14.52 3116 905 2.96 / 815.70 6 70
5 13 1612.76 20 14.52 2572 747 3.71 / 816.44 6 76
6 13 811.00 20 14.66 1482 435 4.14 / 816.88 6 89
7 13 184.68 20 14.83 639 190 4.33 / 817.07 6 92
8 8 -0.24 256 14.83 337 1279 5.61 / 818.35 6 129
Average= 48.14
(KJ/cycle)

Cycle 150 GMT 3/12/2022 23:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 31 14.83 525 241 0.24 / 807.41 6 52
2 7 2012.20 40 14.58 3062 1786 2.03 / 809.20 52 64
3 13 1982.20 20 14.54 3066 892 2.92 / 810.09 6 68
4 13 1487.32 20 14.55 2383 693 3.61 / 810.78 6 77
5 13 936.28 20 14.61 1657 484 4.10 / 811.27 6 87
6 13 107.80 20 14.85 515 153 4.25 / 811.42 6 95
7 13 17.72 20 14.87 375 112 4.36 / 811.53 6 92
8 8 0.44 239 14.82 340 1204 5.57 / 812.74 6 131
Average= 50.80
(KJ/cycle)

Cycle 149 GMT 24/11/2022 2:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 31 14.85 506 233 0.23 / 801.89 6 42
2 7 2011.20 40 14.59 3053 1782 2.01 / 803.67 42 64
3 13 1981.64 20 14.53 3080 895 2.91 / 804.57 6 68
4 13 1446.28 20 14.53 2374 690 3.60 / 805.26 6 78
5 13 770.88 20 14.65 1437 421 4.02 / 805.68 6 87
6 13 233.00 20 14.80 701 207 4.23 / 805.89 6 93
7 13 30.36 20 14.86 391 116 4.34 / 806.00 6 91
8 8 0.04 235 14.81 336 1169 5.51 / 807.17 6 130
Average= 53.81
(KJ/cycle)

Cycle 148 GMT 14/11/2022 5:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 31 14.85 498 229 0.23 / 796.46 6 33
2 7 2015.48 40 14.57 3060 1783 2.01 / 798.25 33 64
3 13 1988.68 20 14.51 3115 904 2.92 / 799.15 6 69
4 13 1347.80 20 14.55 2209 643 3.56 / 799.79 6 79
5 13 833.76 20 14.63 1521 445 4.00 / 800.24 6 88
6 13 92.76 20 14.85 499 148 4.15 / 800.39 6 91
7 8 -0.04 256 14.82 335 1271 5.42 / 801.66 6 129
Average= 57.26
(KJ/cycle)

Cycle 147 GMT 4/11/2022 8: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 31 14.86 474 218 0.22 / 790.91 6 24
2 7 2011.68 40 14.54 3096 1801 2.02 / 792.71 24 64
3 13 1983.08 20 14.51 3043 883 2.90 / 793.59 6 67
4 13 1653.32 20 14.48 2611 756 3.66 / 794.35 6 75
5 13 952.44 20 14.58 1673 488 4.15 / 794.83 6 85
6 13 189.68 20 14.80 641 190 4.34 / 795.02 6 91
7 13 1.12 20 14.87 333 99 4.43 / 795.12 6 91
8 8 0.00 228 14.80 329 1110 5.55 / 796.23 6 131
Average= 61.25
(KJ/cycle)

Cycle 146 GMT 25/10/2022 11:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 31 14.92 476 220 0.22 / 785.47 6 23
2 7 2003.56 40 14.57 3029 1765 1.99 / 787.23 23 62
3 13 1974.80 20 14.51 3087 896 2.88 / 788.13 6 67
4 13 1459.52 20 14.51 2398 696 3.58 / 788.83 6 78
5 13 965.00 20 14.57 1707 497 4.07 / 789.32 6 84
6 13 249.96 20 14.77 735 217 4.29 / 789.54 6 79
7 8 -0.04 244 14.80 318 1148 5.44 / 790.69 6 140
Average= 65.89
(KJ/cycle)

Cycle 145 GMT 15/10/2022 14:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 30 14.88 475 212 0.21 / 780.06 6 27
2 7 2010.48 40 14.58 3077 1795 2.01 / 781.86 6 62
3 13 1911.80 20 14.54 2954 859 2.87 / 782.72 6 67
4 13 1541.24 20 14.53 2454 713 3.58 / 783.43 6 75
5 13 736.24 20 14.66 1416 415 3.99 / 783.84 6 88
6 13 382.84 20 14.76 936 276 4.27 / 784.12 6 89
7 8 0.24 242 14.84 314 1128 5.40 / 785.25 6 134
Average= 71.39
(KJ/cycle)

Cycle 144 GMT 5/10/2022 17: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 30 14.86 505 225 0.23 / 774.46 6 38
2 3 1020.16 1 14.98 1878 28 0.25 / 774.49 6 16
3 7 2005.08 41 14.58 3065 1832 2.09 / 776.32 16 64
4 13 1977.84 20 14.53 3088 897 2.98 / 777.21 6 68
5 13 1691.00 20 14.50 2683 778 3.76 / 777.99 6 74
6 13 896.16 20 14.62 1594 466 4.23 / 778.46 6 86
7 13 241.96 20 14.80 724 214 4.44 / 778.67 6 93
8 13 22.28 20 14.87 372 111 4.55 / 778.78 6 88
9 8 0.08 220 14.83 327 1067 5.62 / 779.85 6 129
Average= 77.99
(KJ/cycle)

Cycle 143 GMT 25/ 9/2022 20:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 31 14.81 497 228 0.23 / 768.78 6 28
2 3 959.52 -1 14.81 497 0 0.00 / 768.78 6 28
3 7 2003.08 40 14.58 3037 1771 2.00 / 770.55 28 63
4 13 1975.16 20 14.52 3104 901 2.90 / 771.46 6 69
5 13 1689.76 20 14.49 2714 787 3.69 / 772.24 6 75
6 13 855.72 20 14.64 1555 455 4.14 / 772.70 6 87
7 13 348.20 20 14.77 875 258 4.40 / 772.96 6 92
8 13 11.04 20 14.88 355 106 4.51 / 773.06 6 88
9 8 0.04 237 14.82 333 1170 5.68 / 774.23 6 130
Average= 86.03
(KJ/cycle)

Cycle 142 GMT 15/ 9/2022 23:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 31 14.86 477 220 0.22 / 763.00 6 19
2 7 2017.00 40 14.53 3076 1788 2.01 / 764.79 19 64
3 13 1997.12 20 14.49 3050 884 2.89 / 765.67 6 66
4 13 1966.00 20 14.41 3090 891 3.78 / 766.56 6 70
5 13 1141.72 20 14.52 1924 559 4.34 / 767.12 6 83
6 13 106.48 20 14.80 512 152 4.49 / 767.27 6 88
7 13 36.68 20 14.81 405 120 4.61 / 767.39 6 88
8 8 -0.04 235 14.76 336 1165 5.78 / 768.56 6 135
Average= 96.07
(KJ/cycle)

Cycle 141 GMT 6/ 9/2022 1:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 31 14.95 459 213 0.21 / 757.47 6 20
2 7 2013.96 40 14.55 3107 1808 2.02 / 759.27 6 62
3 13 1985.12 20 14.49 3172 919 2.94 / 760.19 6 67
4 13 1538.16 20 14.49 2500 724 3.66 / 760.92 6 73
5 13 1034.72 20 14.55 1818 529 4.19 / 761.45 6 83
6 13 171.52 20 14.79 598 177 4.37 / 761.62 6 65
7 13 58.32 20 14.82 412 122 4.49 / 761.75 6 64
8 8 0.12 225 14.79 310 1032 5.52 / 762.78 6 138
Average= 108.97
(KJ/cycle)

Cycle 140 GMT 27/ 8/2022 5: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 31 14.83 482 222 0.22 / 752.04 6 23
2 7 2015.48 40 14.56 3183 1854 2.08 / 753.89 23 64
3 13 1987.16 20 14.51 3148 914 2.99 / 754.80 6 67
4 13 1426.28 20 14.53 2348 682 3.67 / 755.48 6 76
5 13 923.36 20 14.61 1689 494 4.16 / 755.98 6 87
6 13 118.12 20 14.88 513 153 4.32 / 756.13 6 64
7 13 22.72 20 14.91 352 105 4.42 / 756.24 6 62
8 8 0.16 220 14.87 311 1017 5.44 / 757.25 6 131
Average= 126.21
(KJ/cycle)

Cycle 139 GMT 17/ 8/2022 7:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 31 14.88 451 208 0.21 / 746.64 6 19
2 7 2004.52 40 14.55 3069 1786 1.99 / 748.43 6 63
3 13 1978.12 20 14.49 3088 895 2.89 / 749.32 6 68
4 13 1390.88 20 14.52 2280 662 3.55 / 749.99 6 78
5 13 818.28 20 14.60 1490 435 3.99 / 750.42 6 85
6 13 137.24 20 14.78 562 166 4.15 / 750.59 6 89
7 13 62.08 20 14.80 445 132 4.28 / 750.72 6 91
8 13 1.52 20 14.81 339 100 4.38 / 750.82 6 83
9 8 -0.20 204 14.76 330 994 5.38 / 751.81 6 129
Average= 150.36
(KJ/cycle)

Cycle 138 GMT 7/ 8/2022 10:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 29 14.95 457 198 0.20 / 741.12 6 20
2 10 1000.84 3 14.99 1827 82 0.28 / 741.20 6 57
3 3 949.68 -1 14.99 1827 0 0.08 / 741.20 6 57
4 7 2016.20 40 14.57 3104 1809 2.09 / 743.01 57 61
5 13 1993.08 20 14.54 3070 893 2.98 / 743.90 6 64
6 13 1570.40 20 14.51 2542 738 3.72 / 744.64 6 74
7 13 1024.44 20 14.56 1789 521 4.24 / 745.16 6 84
8 13 110.52 20 14.83 497 147 4.39 / 745.31 6 64
9 13 7.00 20 14.86 324 96 4.48 / 745.40 6 61
10 8 0.16 225 14.81 310 1033 5.52 / 746.44 6 138
Average= 186.61
(KJ/cycle)

Cycle 137 GMT 28/ 7/2022 13:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 31 14.87 480 221 0.22 / 735.68 6 26
2 3 965.12 -1 14.87 480 0 0.00 / 735.68 6 26
3 7 2013.12 40 14.60 3067 1791 2.01 / 737.47 26 62
4 13 1987.56 20 14.54 3100 901 2.91 / 738.37 6 64
5 13 1557.52 20 14.54 2500 727 3.64 / 739.09 6 74
6 13 877.80 20 14.64 1583 464 4.10 / 739.56 6 84
7 13 229.96 20 14.85 697 207 4.31 / 739.77 6 77
8 13 16.32 20 14.92 341 102 4.41 / 739.87 6 68
9 8 0.00 223 14.87 317 1051 5.46 / 740.92 6 135
Average= 246.97
(KJ/cycle)

Cycle 136 GMT 18/ 7/2022 16:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 31 14.86 502 231 0.23 / 729.99 6 30
2 7 2003.16 40 14.58 3071 1791 2.02 / 731.78 30 65
3 13 1975.88 20 14.54 3076 895 2.92 / 732.68 6 68
4 13 1473.56 20 14.55 2399 698 3.61 / 733.38 6 79
5 13 891.44 20 14.63 1602 469 4.08 / 733.84 6 87
6 13 406.80 20 14.75 948 280 4.36 / 734.12 6 90
7 13 28.44 20 14.87 396 118 4.48 / 734.24 6 96
8 13 14.56 20 14.86 373 111 4.59 / 734.35 6 95
9 8 -0.12 218 14.81 341 1101 5.69 / 735.45 6 133
Average= 367.73
(KJ/cycle)

Cycle 135 GMT 8/ 7/2022 20:17:10

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 31 14.87 482 222 0.22 / 724.35 6 24
2 7 2006.00 40 14.59 3044 1776 2.00 / 726.13 24 65
3 13 1979.96 20 14.54 3062 890 2.89 / 727.02 6 68
4 13 1514.36 20 14.53 2436 708 3.60 / 727.72 6 78
5 13 862.72 20 14.64 1564 458 4.05 / 728.18 6 88
6 13 288.84 20 14.78 785 232 4.29 / 728.41 6 93
7 13 16.36 20 14.87 380 113 4.40 / 728.53 6 94
8 8 -0.28 240 14.81 347 1233 5.63 / 729.76 6 131
Average= 729.76
(KJ/cycle)

Cycle 133 GMT 19/ 6/2022 1:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 31 14.95 493 228 0.23 / 719.01 6 23
2 7 2003.32 40 14.55 3127 1820 2.05 / 720.83 6 65
3 13 1975.96 20 14.51 3150 914 2.96 / 721.74 6 69
4 13 1340.20 20 14.55 2206 642 3.60 / 722.39 6 77
5 13 750.68 20 14.63 1420 415 4.02 / 722.80 6 89
6 13 159.00 20 14.82 592 175 4.20 / 722.98 6 78
7 8 0.04 239 14.81 325 1150 5.35 / 724.13 6 129
Average= 5.40
(KJ/cycle)

Cycle 132 GMT 9/ 6/2022 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 31 14.86 519 239 0.24 / 713.62 6 44
2 7 2014.48 40 14.61 3067 1792 2.03 / 715.41 44 61
3 13 1986.40 20 14.58 3037 886 2.92 / 716.30 6 63
4 13 1399.44 20 14.59 2257 659 3.58 / 716.96 6 75
5 13 871.32 20 14.65 1617 474 4.05 / 717.43 6 88
6 13 180.56 20 14.88 622 185 4.23 / 717.62 6 68
7 8 0.12 242 14.88 324 1167 5.40 / 718.78 6 131
Average= 5.40
(KJ/cycle)

Cycle 131 GMT 30/ 5/2022 7:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 31 14.84 518 238 0.24 / 708.00 6 52
2 7 2004.68 40 14.60 3076 1796 2.03 / 709.80 52 66
3 13 1977.56 20 14.55 3071 894 2.93 / 710.69 6 70
4 13 1439.92 20 14.56 2337 681 3.61 / 711.37 6 78
5 13 777.92 20 14.68 1450 426 4.03 / 711.80 6 88
6 13 362.36 20 14.78 882 261 4.30 / 712.06 6 91
7 8 0.16 258 14.84 346 1325 5.62 / 713.38 6 129
Average= 5.40
(KJ/cycle)

Cycle 130 GMT 20/ 5/2022 10:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 31 14.86 521 240 0.24 / 702.34 6 49
2 7 2005.92 41 14.60 3067 1836 2.08 / 704.18 49 66
3 13 1980.72 20 14.54 3099 901 2.98 / 705.08 6 70
4 13 1518.80 20 14.54 2464 717 3.69 / 705.80 6 78
5 13 736.08 20 14.69 1393 409 4.10 / 706.21 6 87
6 13 201.88 20 14.83 664 197 4.30 / 706.40 6 92
7 8 -0.04 259 14.83 353 1356 5.66 / 707.76 6 131
Average= 5.40
(KJ/cycle)

Cycle 129 GMT 10/ 5/2022 13:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 30 14.86 523 233 0.23 / 696.61 6 48
2 10 1000.68 3 14.89 1770 79 0.31 / 696.69 6 71
3 3 958.52 -1 14.89 1770 0 0.08 / 696.69 6 71
4 7 2014.04 40 14.59 3073 1793 2.11 / 698.48 71 66
5 13 1985.36 20 14.55 3065 892 3.00 / 699.38 6 69
6 13 1631.72 20 14.53 2590 753 3.75 / 700.13 6 75
7 13 675.20 20 14.71 1314 387 4.14 / 700.52 6 90
8 13 332.64 20 14.79 841 249 4.39 / 700.76 6 90
9 13 4.28 20 14.89 364 108 4.49 / 700.87 6 93
10 8 0.08 238 14.83 349 1232 5.73 / 702.10 6 137
Average= 5.40
(KJ/cycle)

Cycle 128 GMT 30/ 4/2022 16:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 31 14.87 515 237 0.24 / 690.96 6 39
2 3 965.72 -1 14.87 515 0 0.00 / 690.96 6 39
3 7 2005.16 40 14.60 3033 1771 2.01 / 692.73 39 65
4 13 1974.72 20 14.55 3055 889 2.90 / 693.62 6 68
5 13 1710.12 20 14.52 2712 788 3.69 / 694.41 6 75
6 13 775.00 20 14.68 1452 426 4.11 / 694.83 6 90
7 13 208.64 20 14.83 692 205 4.32 / 695.04 6 96
8 8 -0.16 258 14.83 350 1339 5.66 / 696.38 6 134
Average= 5.40
(KJ/cycle)

Cycle 127 GMT 20/ 4/2022 19:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 31 14.85 532 245 0.24 / 685.39 6 59
2 7 2004.92 40 14.61 3049 1782 2.03 / 687.18 59 65
3 13 1979.48 20 14.57 3032 884 2.91 / 688.06 6 69
4 13 1422.76 20 14.58 2327 679 3.59 / 688.74 6 79
5 13 768.68 20 14.69 1436 422 4.01 / 689.16 6 88
6 13 373.08 20 14.78 902 267 4.28 / 689.43 6 92
7 8 0.20 254 14.84 344 1297 5.57 / 690.72 6 129
Average= 5.40
(KJ/cycle)

Cycle 126 GMT 10/ 4/2022 22:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 31 14.86 534 246 0.25 / 679.73 6 64
2 7 2015.04 40 14.60 3082 1800 2.05 / 681.53 64 65
3 13 1989.76 20 14.54 3109 904 2.95 / 682.43 6 69
4 13 1468.08 20 14.57 2383 694 3.64 / 683.13 6 78
5 13 745.84 20 14.69 1412 415 4.06 / 683.54 6 88
6 13 390.00 20 14.77 924 273 4.33 / 683.82 6 90
7 8 0.04 259 14.84 347 1334 5.67 / 685.15 6 135
Average= 5.39
(KJ/cycle)

Cycle 125 GMT 1/ 4/2022 1:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 31 14.84 540 248 0.25 / 673.98 6 63
2 3 1025.92 1 14.96 1862 28 0.28 / 674.01 6 30
3 7 2005.84 40 14.61 3051 1783 2.06 / 675.79 30 64
4 13 1979.44 20 14.57 3054 890 2.95 / 676.68 6 67
5 13 1730.12 20 14.52 2755 800 3.75 / 677.48 6 74
6 13 744.80 20 14.70 1419 417 4.17 / 677.90 6 88
7 13 353.76 20 14.80 888 263 4.43 / 678.16 6 93
8 8 0.12 254 14.85 350 1320 5.75 / 679.48 6 130
Average= 5.39
(KJ/cycle)

Cycle 124 GMT 22/ 3/2022 5: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 31 14.86 530 244 0.24 / 668.12 6 47
2 7 2013.20 40 14.60 3076 1796 2.04 / 669.92 47 65
3 13 1987.92 20 14.56 3057 890 2.93 / 670.81 6 67
4 13 1779.12 20 14.51 2796 811 3.74 / 671.62 6 73
5 13 930.08 20 14.64 1652 484 4.23 / 672.10 6 87
6 13 333.04 20 14.80 839 248 4.47 / 672.35 6 91
7 8 0.16 266 14.83 350 1381 5.85 / 673.73 6 133
Average= 5.39
(KJ/cycle)

Cycle 123 GMT 12/ 3/2022 8:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 30 14.87 520 232 0.23 / 662.26 6 39
2 7 2014.80 40 14.60 3071 1793 2.03 / 664.05 6 65
3 13 1986.64 20 14.54 3104 903 2.93 / 664.96 6 68
4 13 1844.88 20 14.49 2907 842 3.77 / 665.80 6 71
5 13 951.48 20 14.63 1696 496 4.27 / 666.29 6 86
6 13 287.16 20 14.81 798 236 4.50 / 666.53 6 93
7 8 0.00 261 14.84 348 1348 5.85 / 667.88 6 133
Average= 5.39
(KJ/cycle)

Cycle 122 GMT 2/ 3/2022 11: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 30 14.87 519 232 0.23 / 656.74 6 49
2 7 2011.16 40 14.60 3055 1784 2.02 / 658.52 6 65
3 13 1981.20 20 14.54 3093 899 2.92 / 659.42 6 69
4 13 1426.44 20 14.57 2323 677 3.59 / 660.10 6 79
5 13 796.68 20 14.67 1483 435 4.03 / 660.53 6 89
6 13 154.12 20 14.85 597 177 4.20 / 660.71 6 94
7 8 -0.12 258 14.84 344 1317 5.52 / 662.03 6 131
Average= 5.38
(KJ/cycle)

Cycle 121 GMT 20/ 2/2022 14: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 33 14.87 519 255 0.25 / 651.14 6 53
2 3 865.88 -2 14.87 519 0 0.00 / 651.14 6 53
3 7 2012.24 40 14.61 3071 1795 2.05 / 652.93 53 63
4 13 1985.96 20 14.56 3094 901 2.95 / 653.84 6 70
5 13 1413.52 20 14.58 2285 666 3.62 / 654.50 6 78
6 13 1024.08 20 14.62 1777 520 4.14 / 655.02 6 85
7 13 286.40 20 14.83 791 235 4.37 / 655.26 6 92
8 8 0.28 246 14.86 342 1250 5.62 / 656.51 6 132
Average= 5.38
(KJ/cycle)

Cycle 120 GMT 10/ 2/2022 16:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 32 14.83 538 255 0.26 / 645.52 6 82
2 3 1062.92 2 14.93 1879 56 0.31 / 645.57 6 63
3 7 2015.44 40 14.61 3086 1803 2.11 / 647.38 63 67
4 13 1990.80 20 14.57 3069 894 3.01 / 648.27 6 68
5 13 1411.84 20 14.60 2280 666 3.67 / 648.94 6 78
6 13 671.96 20 14.72 1308 385 4.06 / 649.32 6 89
7 13 285.52 20 14.83 783 232 4.29 / 649.55 6 94
8 8 -0.12 258 14.86 347 1330 5.62 / 650.89 6 133
Average= 5.38
(KJ/cycle)

Cycle 119 GMT 31/ 1/2022 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 31 14.84 522 240 0.24 / 639.67 6 81
2 7 2004.88 40 14.62 3051 1784 2.02 / 641.45 6 65
3 13 1976.88 20 14.56 3096 902 2.93 / 642.35 6 69
4 13 1546.28 20 14.56 2512 731 3.66 / 643.08 6 78
5 13 1184.40 20 14.59 1999 583 4.24 / 643.67 6 83
6 13 180.32 20 14.87 641 191 4.43 / 643.86 6 94
7 13 30.48 20 14.90 410 122 4.55 / 643.98 6 92
8 8 0.00 242 14.85 357 1283 5.84 / 645.26 6 132
Average= 5.38
(KJ/cycle)

Cycle 118 GMT 21/ 1/2022 23:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 31 14.83 530 244 0.24 / 633.98 6 77
2 7 2013.92 40 14.61 3072 1795 2.04 / 635.78 77 65
3 13 1987.84 20 14.55 3113 906 2.94 / 636.68 6 69
4 13 1580.48 20 14.56 2515 732 3.68 / 637.42 6 75
5 13 800.60 20 14.69 1483 436 4.11 / 637.85 6 88
6 13 130.72 20 14.88 567 169 4.28 / 638.02 6 94
7 13 32.76 20 14.91 412 123 4.40 / 638.14 6 93
8 8 0.08 244 14.85 354 1283 5.69 / 639.43 6 131
Average= 5.37
(KJ/cycle)

Cycle 117 GMT 12/ 1/2022 2: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 31 14.84 520 239 0.24 / 628.36 6 76
2 7 2015.16 40 14.62 3056 1787 2.03 / 630.15 76 65
3 13 1986.36 20 14.57 3039 886 2.91 / 631.03 6 69
4 13 1506.52 20 14.57 2433 709 3.62 / 631.74 6 78
5 13 829.60 20 14.68 1528 449 4.07 / 632.19 6 87
6 13 234.92 20 14.84 713 212 4.28 / 632.40 6 95
7 13 35.24 20 14.90 413 123 4.40 / 632.52 6 92
8 8 0.36 232 14.85 353 1216 5.62 / 633.74 6 129
Average= 5.37
(KJ/cycle)

Cycle 116 GMT 2/ 1/2022 5: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 31 14.85 521 240 0.24 / 622.88 6 69
2 7 1907.60 40 14.64 2945 1725 1.96 / 624.60 6 69
3 13 1880.60 20 14.58 3002 875 2.84 / 625.48 6 75
4 13 1418.20 20 14.61 2320 678 3.52 / 626.16 6 80
5 13 790.52 20 14.70 1465 431 3.95 / 626.59 6 88
6 13 142.96 20 14.88 585 174 4.12 / 626.76 6 95
7 13 31.56 20 14.91 410 122 4.24 / 626.88 6 93
8 8 516.64 237 14.85 351 1235 5.48 / 628.12 6 129
Average= 5.37
(KJ/cycle)

Cycle 115 GMT 23/12/2021 4:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 31 14.85 535 246 0.25 / 617.77 6 65
2 7 1721.40 40 14.70 2709 1593 1.84 / 619.36 6 72
3 13 1696.68 20 14.67 2684 787 2.63 / 620.15 6 74
4 13 1214.20 20 14.68 2023 594 3.22 / 620.74 6 82
5 13 598.68 20 14.78 1214 359 3.58 / 621.10 6 91
6 13 107.96 20 14.90 534 159 3.74 / 621.26 6 94
7 13 18.84 20 14.92 395 118 3.86 / 621.38 6 93
8 8 358.64 238 14.86 356 1259 5.12 / 622.64 6 130
Average= 5.37
(KJ/cycle)

Cycle 114 GMT 13/12/2021 4:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 31 14.86 522 240 0.24 / 612.49 6 65
2 7 1656.56 40 14.73 2619 1543 1.78 / 614.04 6 75
3 13 1635.48 20 14.69 2587 760 2.54 / 614.80 6 75
4 13 1497.80 20 14.65 2418 708 3.25 / 615.51 6 78
5 13 829.20 20 14.73 1520 448 3.70 / 615.95 6 89
6 13 233.68 20 14.87 710 211 3.91 / 616.16 6 93
7 13 16.40 20 14.93 387 116 4.03 / 616.28 6 94
8 8 184.64 235 14.86 356 1243 5.27 / 617.52 6 139
Average= 5.37
(KJ/cycle)

Cycle 113 GMT 3/12/2021 4:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 31 14.87 535 247 0.25 / 607.34 6 56
2 7 1672.60 40 14.71 2654 1562 1.81 / 608.90 56 75
3 13 1649.36 20 14.68 2651 778 2.59 / 609.68 6 75
4 13 1400.16 20 14.66 2288 671 3.26 / 610.35 6 80
5 13 749.60 20 14.74 1413 417 3.67 / 610.77 6 90
6 13 128.28 20 14.90 558 166 3.84 / 610.93 6 95
7 13 14.44 20 14.93 386 115 3.96 / 611.05 6 92
8 8 233.28 231 14.87 351 1206 5.16 / 612.25 6 133
Average= 5.37
(KJ/cycle)

Cycle 112 GMT 23/11/2021 4:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 31 14.88 547 252 0.25 / 602.76 6 50
2 7 1298.40 40 14.85 2135 1268 1.52 / 604.03 50 78
3 13 1281.16 20 14.82 2124 630 2.15 / 604.66 6 78
4 13 1249.16 20 14.78 2081 615 2.77 / 605.27 6 80
5 13 676.36 20 14.83 1314 390 3.15 / 605.66 6 92
6 13 53.76 20 14.96 436 130 3.29 / 605.79 6 91
7 13 29.12 20 14.95 401 120 3.41 / 605.91 6 94
8 8 -0.20 225 14.90 352 1180 4.59 / 607.09 6 136
Average= 5.37
(KJ/cycle)

Cycle 111 GMT 13/11/2021 6: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 30 14.89 512 229 0.23 / 598.25 6 43
2 3 1022.12 1 14.98 1887 28 0.26 / 598.28 6 16
3 7 1281.28 40 14.87 2092 1244 1.50 / 599.53 16 76
4 13 1281.72 20 14.83 2108 625 2.13 / 600.15 6 79
5 13 1251.96 20 14.78 2090 618 2.74 / 600.77 6 82
6 13 507.08 20 14.87 1083 322 3.07 / 601.09 6 87
7 13 47.76 20 14.97 428 128 3.19 / 601.22 6 88
8 8 0.04 249 14.91 347 1288 4.48 / 602.51 6 146
Average= 5.38
(KJ/cycle)

Cycle 110 GMT 3/11/2021 7: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 30 14.88 514 229 0.23 / 593.53 6 43
2 7 1496.16 40 14.79 2411 1426 1.66 / 594.96 43 76
3 13 1475.60 20 14.75 2401 708 2.36 / 595.66 6 78
4 13 1305.84 20 14.73 2137 630 2.99 / 596.29 6 80
5 13 510.40 20 14.84 1081 321 3.31 / 596.61 6 92
6 13 57.52 20 14.94 439 131 3.45 / 596.75 6 90
7 8 89.52 251 14.89 342 1278 4.72 / 598.02 6 130
Average= 5.39
(KJ/cycle)

Cycle 109 GMT 24/10/2021 7:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 30 14.87 515 230 0.23 / 588.37 6 44
2 7 1773.12 40 14.69 2760 1622 1.85 / 590.00 44 72
3 13 1746.08 20 14.65 2783 815 2.67 / 590.81 6 76
4 13 1334.40 20 14.65 2193 643 3.31 / 591.45 6 81
5 13 669.40 20 14.75 1300 383 3.69 / 591.84 6 92
6 13 106.64 20 14.90 514 153 3.85 / 591.99 6 92
7 13 34.80 20 14.92 407 121 3.97 / 592.11 6 90
8 8 379.48 231 14.86 346 1188 5.16 / 593.30 6 134
Average= 5.39
(KJ/cycle)

Cycle 108 GMT 14/10/2021 7:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 30 14.88 515 230 0.23 / 582.76 6 40
2 7 2004.12 40 14.61 3062 1789 2.02 / 584.55 40 64
3 13 1976.28 20 14.56 3063 892 2.91 / 585.44 6 67
4 13 1728.48 20 14.52 2750 799 3.71 / 586.24 6 75
5 13 644.76 20 14.74 1291 381 4.09 / 586.62 6 91
6 13 131.36 20 14.88 566 168 4.26 / 586.79 6 93
7 13 26.56 20 14.91 405 121 4.38 / 586.91 6 91
8 8 0.00 235 14.85 353 1232 5.61 / 588.14 6 130
Average= 5.40
(KJ/cycle)

Cycle 107 GMT 4/10/2021 10:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 30 14.90 515 230 0.23 / 577.38 6 37
2 7 2011.52 40 14.62 3065 1792 2.02 / 579.17 6 64
3 13 1983.20 20 14.57 3056 891 2.91 / 580.06 6 67
4 13 1260.64 20 14.62 2091 611 3.52 / 580.67 6 81
5 13 693.60 20 14.72 1343 395 3.92 / 581.07 6 89
6 13 59.80 20 14.91 443 132 4.05 / 581.20 6 88
7 13 33.56 20 14.91 411 123 4.17 / 581.32 6 88
8 8 0.00 235 14.86 346 1208 5.38 / 582.53 6 133
Average= 5.39
(KJ/cycle)

Cycle 106 GMT 24/ 9/2021 13: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 30 14.89 527 235 0.24 / 571.82 6 35
2 7 2003.48 41 14.61 3082 1846 2.08 / 573.66 35 64
3 13 1976.36 20 14.57 3090 900 2.98 / 574.56 6 70
4 13 1474.96 20 14.59 2386 696 3.68 / 575.26 6 78
5 13 846.48 20 14.68 1556 457 4.14 / 575.72 6 89
6 13 42.96 20 14.93 422 126 4.26 / 575.84 6 86
7 13 14.04 20 14.92 374 112 4.37 / 575.95 6 88
8 13 0.84 20 14.92 353 105 4.48 / 576.06 6 81
9 8 0.20 214 14.86 343 1091 5.57 / 577.15 6 133
Average= 5.39
(KJ/cycle)

Cycle 105 GMT 14/ 9/2021 15:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 30 14.89 513 229 0.23 / 566.00 6 36
2 7 2004.76 40 14.62 3066 1793 2.02 / 567.80 36 65
3 13 1976.12 20 14.57 3080 898 2.92 / 568.69 6 70
4 13 1722.96 20 14.53 2750 799 3.72 / 569.49 6 74
5 13 960.40 20 14.65 1700 498 4.22 / 569.99 6 87
6 13 344.44 20 14.81 874 259 4.48 / 570.25 6 93
7 13 25.92 20 14.91 393 117 4.59 / 570.37 6 90
8 13 13.44 20 14.90 372 111 4.70 / 570.48 6 89
9 8 0.04 216 14.85 344 1103 5.81 / 571.58 6 131
Average= 5.39
(KJ/cycle)

Cycle 104 GMT 4/ 9/2021 19: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 29 14.90 514 222 0.22 / 560.30 6 33
2 3 1055.48 1 14.96 1894 28 0.25 / 560.33 6 61
3 7 2004.60 41 14.60 3099 1855 2.11 / 562.18 61 65
4 13 1974.32 20 14.58 3046 888 2.99 / 563.07 6 68
5 13 1357.28 20 14.60 2242 655 3.65 / 563.72 6 80
6 13 807.56 20 14.69 1487 437 4.09 / 564.16 6 87
7 13 338.04 20 14.81 863 256 4.34 / 564.42 6 92
8 13 20.76 20 14.91 385 115 4.46 / 564.53 6 90
9 13 10.20 20 14.90 372 111 4.57 / 564.64 6 87
10 8 0.04 221 14.85 345 1132 5.70 / 565.77 6 130
Average= 5.39
(KJ/cycle)

Cycle 103 GMT 25/ 8/2021 22: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 30 14.90 507 227 0.23 / 554.62 6 32
2 3 965.84 -1 14.90 507 0 0.00 / 554.62 6 32
3 7 2011.52 41 14.62 3048 1827 2.05 / 556.45 32 64
4 13 1984.00 20 14.57 3105 905 2.96 / 557.35 6 69
5 13 1613.84 20 14.56 2564 747 3.71 / 558.10 6 75
6 13 816.16 20 14.70 1478 435 4.14 / 558.54 6 86
7 13 177.08 20 14.87 628 187 4.33 / 558.72 6 93
8 13 15.80 20 14.92 379 113 4.44 / 558.84 6 90
9 13 5.84 20 14.91 366 109 4.55 / 558.94 6 88
10 8 0.00 220 14.86 346 1131 5.68 / 560.08 6 133
Average= 5.39
(KJ/cycle)

Cycle 102 GMT 16/ 8/2021 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 30 14.91 501 224 0.22 / 548.96 6 33
2 7 2015.32 40 14.61 3080 1800 2.02 / 550.76 33 63
3 13 1987.36 20 14.57 3078 897 2.92 / 551.65 6 68
4 13 1664.52 20 14.54 2673 777 3.70 / 552.43 6 77
5 13 829.52 20 14.69 1529 449 4.15 / 552.88 6 87
6 13 198.16 20 14.86 667 198 4.35 / 553.08 6 95
7 13 17.80 20 14.92 377 112 4.46 / 553.19 6 89
8 13 5.56 20 14.91 354 106 4.56 / 553.30 6 89
9 8 -0.12 218 14.86 339 1098 5.66 / 554.40 6 135
Average= 5.38
(KJ/cycle)

Cycle 101 GMT 6/ 8/2021 3:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 30 14.90 496 222 0.22 / 543.44 6 34
2 7 2016.80 40 14.62 3069 1795 2.02 / 545.24 34 65
3 13 1991.68 20 14.57 3048 888 2.90 / 546.12 6 66
4 13 1391.60 20 14.60 2291 669 3.57 / 546.79 6 78
5 13 820.96 20 14.69 1498 440 4.01 / 547.23 6 86
6 13 136.68 20 14.89 572 170 4.18 / 547.40 6 91
7 13 14.76 20 14.92 381 114 4.30 / 547.52 6 89
8 13 4.92 20 14.92 363 108 4.41 / 547.63 6 88
9 8 0.12 216 14.86 345 1107 5.51 / 548.73 6 129
Average= 5.38
(KJ/cycle)

Cycle 100 GMT 27/ 7/2021 6:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 30 14.91 510 228 0.23 / 537.84 6 34
2 7 2014.40 40 14.62 3048 1782 2.01 / 539.63 34 64
3 13 1987.20 20 14.57 3096 902 2.91 / 540.53 6 69
4 13 1533.12 20 14.58 2477 722 3.64 / 541.25 6 77
5 13 871.04 20 14.68 1584 465 4.10 / 541.72 6 88
6 13 147.24 20 14.88 590 176 4.28 / 541.89 6 91
7 13 14.76 20 14.92 382 114 4.39 / 542.00 6 88
8 13 3.64 20 14.91 363 108 4.50 / 542.11 6 84
9 8 0.08 216 14.86 345 1107 5.61 / 543.22 6 129
Average= 5.38
(KJ/cycle)

Cycle 99 GMT 17/ 7/2021 9:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 30 14.90 510 228 0.23 / 532.40 6 41
2 7 2009.84 40 14.61 3085 1803 2.03 / 534.21 41 65
3 13 1843.84 20 14.60 2881 841 2.87 / 535.05 6 70
4 13 1552.08 20 14.57 2502 729 3.60 / 535.78 6 78
5 13 723.48 20 14.72 1386 408 4.01 / 536.18 6 90
6 13 83.00 20 14.92 486 145 4.15 / 536.33 6 87
7 13 8.16 20 14.93 364 109 4.26 / 536.44 6 89
8 8 0.08 230 14.87 344 1177 5.44 / 537.61 6 130
Average= 5.38
(KJ/cycle)

Cycle 98 GMT 7/ 7/2021 12:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 30 14.91 513 229 0.23 / 526.83 6 36
2 7 2014.40 40 14.63 3056 1788 2.02 / 528.62 36 65
3 13 1986.44 20 14.58 3053 890 2.91 / 529.51 6 68
4 13 1510.12 20 14.58 2442 712 3.62 / 530.22 6 77
5 13 924.60 20 14.67 1640 481 4.10 / 530.70 6 86
6 13 173.16 20 14.88 624 186 4.29 / 530.89 6 89
7 13 11.04 20 14.93 366 109 4.40 / 531.00 6 87
8 8 -0.04 232 14.87 341 1176 5.57 / 532.18 6 136
Average= 5.38
(KJ/cycle)

Cycle 97 GMT 27/ 6/2021 15:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 30 14.88 517 231 0.23 / 521.32 6 49
2 7 2011.40 40 14.63 3067 1795 2.03 / 523.11 49 64
3 13 1982.24 20 14.58 3076 897 2.92 / 524.01 6 68
4 13 1370.04 20 14.61 2259 660 3.58 / 524.67 6 80
5 13 859.88 20 14.69 1572 462 4.04 / 525.13 6 87
6 13 79.52 20 14.92 483 144 4.19 / 525.28 6 85
7 8 0.12 256 14.88 348 1326 5.51 / 526.60 6 142
Average= 5.37
(KJ/cycle)

Cycle 96 GMT 17/ 6/2021 18:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 30 14.88 531 237 0.24 / 515.74 6 56
2 7 2005.36 40 14.63 3058 1790 2.03 / 517.53 56 64
3 13 1979.44 20 14.58 3065 894 2.92 / 518.42 6 69
4 13 1553.28 20 14.58 2492 727 3.65 / 519.15 6 75
5 13 761.32 20 14.72 1430 421 4.07 / 519.57 6 89
6 13 189.68 20 14.88 655 195 4.26 / 519.77 6 92
7 8 0.00 256 14.88 347 1322 5.58 / 521.09 6 134
Average= 5.37
(KJ/cycle)

Cycle 95 GMT 7/ 6/2021 21: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 30 14.88 524 234 0.23 / 510.18 6 50
2 7 2003.36 41 14.63 3055 1832 2.07 / 512.01 50 64
3 13 1977.60 20 14.58 3110 907 2.97 / 512.92 6 67
4 13 1441.88 20 14.61 2344 685 3.66 / 513.61 6 78
5 13 712.04 20 14.73 1384 408 4.07 / 514.01 6 90
6 13 143.40 20 14.90 583 174 4.24 / 514.19 6 88
7 13 10.24 20 14.94 371 111 4.35 / 514.30 6 84
8 8 0.08 235 14.88 345 1206 5.56 / 515.50 6 131
Average= 5.37
(KJ/cycle)

Cycle 94 GMT 28/ 5/2021 23:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 30 14.90 513 229 0.23 / 504.45 6 41
2 7 2016.08 40 14.61 3112 1819 2.05 / 506.27 41 64
3 13 1989.44 20 14.58 3079 898 2.95 / 507.17 6 67
4 13 1586.88 20 14.56 2579 751 3.70 / 507.92 6 77
5 13 840.76 20 14.70 1532 450 4.15 / 508.37 6 88
6 13 372.52 20 14.81 907 269 4.42 / 508.64 6 93
7 8 -0.04 258 14.87 341 1308 5.72 / 509.95 6 131
Average= 5.37
(KJ/cycle)

Cycle 93 GMT 19/ 5/2021 3: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 30 14.91 522 233 0.23 / 498.95 6 41
2 7 2014.76 40 14.63 3063 1792 2.03 / 500.74 41 64
3 13 1986.00 20 14.58 3073 896 2.92 / 501.64 6 66
4 13 1436.60 20 14.60 2342 684 3.61 / 502.32 6 78
5 13 734.88 20 14.72 1414 416 4.02 / 502.74 6 89
6 13 144.88 20 14.89 584 174 4.20 / 502.91 6 89
7 8 0.20 256 14.88 344 1310 5.51 / 504.22 6 137
Average= 5.36
(KJ/cycle)

Cycle 92 GMT 9/ 5/2021 5:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 30 14.88 530 237 0.24 / 493.44 6 49
2 7 2011.56 40 14.64 3055 1789 2.03 / 495.23 49 63
3 13 1982.16 20 14.57 3143 916 2.94 / 496.15 6 71
4 13 1584.16 20 14.58 2559 746 3.69 / 496.89 6 75
5 13 697.44 20 14.75 1352 399 4.09 / 497.29 6 89
6 13 194.72 20 14.89 650 194 4.28 / 497.48 6 88
7 8 0.28 242 14.89 342 1232 5.51 / 498.72 6 133
Average= 5.36
(KJ/cycle)

Cycle 91 GMT 29/ 4/2021 8:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 30 14.89 513 229 0.23 / 487.83 6 33
2 7 2016.16 40 14.62 3076 1799 2.03 / 489.63 6 64
3 13 1988.56 20 14.56 3109 905 2.93 / 490.53 6 69
4 13 1332.32 20 14.61 2213 647 3.58 / 491.18 6 80
5 13 842.72 20 14.69 1531 450 4.03 / 491.63 6 87
6 13 290.24 20 14.83 805 239 4.27 / 491.87 6 94
7 8 0.00 259 14.86 347 1336 5.60 / 493.20 6 130
Average= 5.36
(KJ/cycle)

Cycle 90 GMT 19/ 4/2021 11:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 30 14.88 513 229 0.23 / 482.35 6 38
2 3 1022.24 1 15.03 1895 28 0.26 / 482.38 6 22
3 7 2012.80 40 14.61 3089 1805 2.06 / 484.18 22 64
4 13 1984.24 20 14.58 3051 890 2.95 / 485.07 6 67
5 13 1357.96 20 14.60 2266 662 3.61 / 485.73 6 80
6 13 757.28 20 14.70 1432 421 4.04 / 486.16 6 89
7 13 155.00 20 14.87 598 178 4.21 / 486.33 6 90
8 8 0.00 247 14.86 345 1266 5.48 / 487.60 6 130
Average= 5.36
(KJ/cycle)

Cycle 89 GMT 9/ 4/2021 14:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 31 14.88 512 236 0.24 / 476.77 6 35
2 3 966.36 -1 14.88 512 0 0.00 / 476.77 6 35
3 7 2004.08 40 14.61 3062 1789 2.03 / 478.56 35 61
4 13 1975.84 20 14.56 3102 903 2.93 / 479.47 6 67
5 13 1504.56 20 14.57 2429 708 3.64 / 480.18 6 75
6 13 956.48 20 14.64 1708 500 4.14 / 480.68 6 84
7 13 322.52 20 14.81 862 255 4.39 / 480.93 6 85
8 8 -0.20 239 14.86 335 1190 5.58 / 482.12 6 131
Average= 5.36
(KJ/cycle)

Cycle 88 GMT 30/ 3/2021 17:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 31 14.92 497 230 0.23 / 471.32 6 32
2 7 2017.28 40 14.61 3067 1792 2.02 / 473.11 6 60
3 13 1991.68 20 14.53 3172 922 2.94 / 474.03 6 67
4 13 1414.60 20 14.56 2335 680 3.62 / 474.71 6 77
5 13 1006.44 20 14.61 1783 521 4.14 / 475.23 6 84
6 13 25.56 20 14.91 377 112 4.26 / 475.35 6 67
7 8 0.04 242 14.85 332 1193 5.45 / 476.54 6 135
Average= 5.35
(KJ/cycle)

Cycle 87 GMT 20/ 3/2021 20:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 31 14.90 512 236 0.24 / 465.91 6 36
2 7 2006.28 40 14.60 3174 1854 2.09 / 467.77 36 61
3 13 1980.72 20 14.56 3136 913 3.00 / 468.68 6 63
4 13 1396.08 20 14.58 2324 678 3.68 / 469.36 6 75
5 13 760.24 20 14.70 1484 436 4.12 / 469.79 6 84
6 13 71.04 20 14.92 442 132 4.25 / 469.93 6 61
7 8 0.04 239 14.88 327 1163 5.41 / 471.09 6 132
Average= 5.35
(KJ/cycle)

Cycle 86 GMT 10/ 3/2021 23:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 31 14.89 522 241 0.24 / 460.53 6 36
2 7 2013.84 41 14.60 3179 1903 2.14 / 462.44 36 62
3 13 1985.28 20 14.55 3158 919 3.06 / 463.36 6 66
4 13 1198.80 20 14.64 2018 591 3.65 / 463.95 6 76
5 13 907.84 20 14.66 1678 492 4.15 / 464.44 6 85
6 8 0.20 258 14.89 322 1237 5.38 / 465.68 6 136
Average= 5.35
(KJ/cycle)

Cycle 85 GMT 1/ 3/2021 2:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 31 14.89 506 234 0.23 / 454.84 6 36
2 7 2003.08 40 14.62 3083 1803 2.04 / 456.65 6 60
3 13 1973.92 20 14.55 3155 918 2.95 / 457.57 6 65
4 13 1540.60 20 14.56 2537 739 3.69 / 458.30 6 74
5 13 1116.72 20 14.60 1955 571 4.26 / 458.88 6 82
6 13 293.56 20 14.84 801 238 4.50 / 459.11 6 71
7 8 0.04 242 14.87 328 1180 5.68 / 460.29 6 138
Average= 5.35
(KJ/cycle)

Cycle 84 GMT 19/ 2/2021 5:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 30 14.91 494 221 0.22 / 449.36 6 32
2 3 1027.20 1 15.08 1883 28 0.25 / 449.39 6 22
3 7 2005.16 40 14.62 3105 1816 2.07 / 451.21 22 59
4 13 1977.48 20 14.57 3124 910 2.98 / 452.12 6 65
5 13 1485.84 20 14.57 2453 715 3.69 / 452.83 6 74
6 13 943.52 20 14.65 1745 511 4.20 / 453.34 6 85
7 13 4.24 20 14.93 338 101 4.30 / 453.44 6 64
8 8 0.08 239 14.88 328 1166 5.47 / 454.61 6 133
Average= 5.35
(KJ/cycle)

Cycle 83 GMT 9/ 2/2021 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 30 14.92 500 224 0.22 / 443.84 6 35
2 7 2005.64 40 14.61 3167 1851 2.07 / 445.69 6 61
3 13 1978.24 20 14.57 3129 912 2.99 / 446.60 6 64
4 13 1423.92 20 14.59 2362 689 3.68 / 447.29 6 75
5 13 923.32 20 14.65 1712 502 4.18 / 447.79 6 86
6 13 181.96 20 14.88 625 186 4.36 / 447.98 6 66
7 8 0.36 239 14.88 327 1163 5.53 / 449.14 6 131
Average= 5.35
(KJ/cycle)

Cycle 82 GMT 30/ 1/2021 12:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 32 14.90 518 247 0.25 / 438.16 6 34
2 3 942.04 -1 14.90 518 0 0.00 / 438.16 6 34
3 7 2003.96 40 14.63 3119 1825 2.07 / 439.98 34 62
4 13 1972.92 20 14.57 3115 908 2.98 / 440.89 6 67
5 13 1483.40 20 14.58 2456 716 3.70 / 441.61 6 75
6 13 999.40 20 14.65 1788 524 4.22 / 442.13 6 83
7 13 320.72 20 14.84 848 252 4.47 / 442.38 6 76
8 13 121.84 20 14.89 533 159 4.63 / 442.54 6 71
9 8 0.08 220 14.88 328 1074 5.70 / 443.62 6 136
Average= 5.34
(KJ/cycle)

Cycle 81 GMT 20/ 1/2021 15:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 32 14.93 508 243 0.24 / 432.68 6 32
2 7 2003.08 40 14.59 3179 1855 2.10 / 434.53 32 65
3 13 1972.40 20 14.55 3147 916 3.01 / 435.45 6 68
4 13 1408.32 20 14.59 2323 678 3.69 / 436.13 6 77
5 13 772.68 20 14.69 1492 438 4.13 / 436.56 6 89
6 13 131.96 20 14.88 560 167 4.30 / 436.73 6 75
7 13 3.28 20 14.92 343 102 4.40 / 436.83 6 74
8 8 0.08 221 14.87 328 1078 5.48 / 437.91 6 157
Average= 5.34
(KJ/cycle)

Cycle 80 GMT 10/ 1/2021 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 32 14.93 500 239 0.24 / 427.18 6 30
2 7 2012.84 41 14.62 3110 1864 2.10 / 429.05 6 59
3 13 1984.08 20 14.58 3077 897 3.00 / 429.95 6 62
4 13 1605.44 20 14.55 2610 760 3.76 / 430.71 6 72
5 13 785.60 20 14.70 1522 447 4.21 / 431.15 6 85
6 13 94.24 20 14.91 480 143 4.35 / 431.30 6 61
7 8 0.16 239 14.89 320 1139 5.49 / 432.43 6 138
Average= 5.34
(KJ/cycle)

Cycle 79 GMT 31/12/2020 21: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 32 14.91 492 235 0.23 / 421.78 6 29
2 7 2013.12 40 14.60 3175 1854 2.09 / 423.64 6 60
3 13 1983.72 20 14.56 3147 916 3.01 / 424.55 6 63
4 13 1502.60 20 14.57 2451 714 3.72 / 425.27 6 73
5 13 792.24 20 14.71 1533 451 4.17 / 425.72 6 81
6 8 0.20 258 14.91 319 1227 5.40 / 426.95 6 137
Average= 5.34
(KJ/cycle)

Cycle 78 GMT 22/12/2020 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 32 14.92 485 232 0.23 / 416.27 6 27
2 7 2013.40 40 14.61 3165 1850 2.08 / 418.12 27 60
3 13 1988.16 20 14.56 3157 919 3.00 / 419.04 6 63
4 13 1408.20 20 14.58 2364 689 3.69 / 419.73 6 76
5 13 839.04 20 14.68 1607 472 4.16 / 420.20 6 84
6 13 208.44 20 14.88 665 198 4.36 / 420.39 6 62
7 8 0.16 239 14.89 324 1153 5.51 / 421.55 6 137
Average= 5.34
(KJ/cycle)

Cycle 77 GMT 12/12/2020 3:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 31 14.93 498 230 0.23 / 410.83 6 26
2 7 2003.68 40 14.61 3160 1847 2.08 / 412.67 6 61
3 13 1975.28 20 14.57 3128 911 2.99 / 413.58 6 63
4 13 1344.60 20 14.61 2244 656 3.64 / 414.24 6 75
5 13 822.68 20 14.69 1582 465 4.11 / 414.70 6 84
6 13 159.20 20 14.90 584 174 4.28 / 414.88 6 60
7 8 0.16 239 14.89 325 1157 5.44 / 416.04 6 137
Average= 5.33
(KJ/cycle)

Cycle 76 GMT 2/12/2020 6: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 30 14.97 500 225 0.22 / 405.23 6 25
2 3 1057.84 1 15.08 1924 29 0.25 / 405.25 6 46
3 7 2003.48 40 14.61 3151 1841 2.10 / 407.10 46 61
4 13 1971.80 20 14.57 3120 909 3.00 / 408.00 6 62
5 13 1442.84 20 14.59 2401 701 3.70 / 408.71 6 74
6 13 880.80 20 14.67 1662 488 4.19 / 409.19 6 84
7 13 287.12 20 14.85 782 232 4.42 / 409.43 6 65
8 8 0.04 242 14.88 325 1170 5.59 / 410.60 6 130
Average= 5.33
(KJ/cycle)

Cycle 75 GMT 22/11/2020 9:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 30 14.99 485 218 0.22 / 399.69 6 22
2 7 2011.92 40 14.64 3182 1863 2.08 / 401.55 22 60
3 13 1980.68 20 14.60 3146 919 3.00 / 402.47 6 65
4 13 1336.08 20 14.64 2239 656 3.66 / 403.13 6 76
5 13 927.72 20 14.69 1727 507 4.16 / 403.64 6 84
6 13 193.72 20 14.92 639 191 4.35 / 403.83 6 61
7 8 0.08 242 14.93 325 1174 5.53 / 405.00 6 141
Average= 5.33
(KJ/cycle)

Cycle 74 GMT 12/11/2020 12:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 30 14.95 506 227 0.23 / 394.18 6 34
2 7 2014.72 40 14.65 3086 1808 2.04 / 395.99 34 64
3 13 1989.32 20 14.61 3080 900 2.94 / 396.89 6 67
4 13 1499.04 20 14.61 2447 715 3.65 / 397.60 6 78
5 13 810.40 20 14.73 1527 450 4.10 / 398.05 6 88
6 13 171.28 20 14.93 635 190 4.29 / 398.24 6 89
7 8 0.40 242 14.94 340 1229 5.52 / 399.47 6 141
Average= 5.33
(KJ/cycle)

Cycle 73 GMT 2/11/2020 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 30 14.97 492 221 0.22 / 388.85 6 30
2 7 2012.76 40 14.65 3090 1811 2.03 / 390.66 6 64
3 13 1983.84 20 14.60 3141 917 2.95 / 391.58 6 69
4 13 1326.40 20 14.64 2224 651 3.60 / 392.23 6 80
5 13 551.80 20 14.81 1170 347 3.95 / 392.58 6 91
6 13 53.24 20 14.96 441 132 4.08 / 392.71 6 88
7 8 0.40 244 14.92 342 1245 5.32 / 393.95 6 130
Average= 5.32
(KJ/cycle)

Cycle 72 GMT 23/10/2020 17:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 30 14.93 507 227 0.23 / 383.28 6 38
2 7 2011.48 40 14.65 3094 1813 2.04 / 385.09 38 64
3 13 1982.28 20 14.62 3043 890 2.93 / 385.98 6 67
4 13 1531.36 20 14.61 2488 727 3.66 / 386.71 6 77
5 13 805.32 20 14.75 1486 438 4.10 / 387.15 6 88
6 13 284.08 20 14.89 792 236 4.33 / 387.38 6 95
7 13 38.36 20 14.97 405 121 4.45 / 387.51 6 90
8 8 0.08 223 14.92 338 1125 5.58 / 388.63 6 133
Average= 5.32
(KJ/cycle)

Cycle 71 GMT 13/10/2020 20:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 31 14.93 507 235 0.23 / 377.66 6 28
2 3 925.80 -1 14.93 507 0 0.00 / 377.66 6 28
3 7 2015.40 40 14.65 3078 1804 2.04 / 379.46 28 64
4 13 1988.00 20 14.59 3135 915 2.95 / 380.38 6 68
5 13 1585.60 20 14.60 2579 753 3.71 / 381.13 6 75
6 13 806.16 20 14.74 1489 439 4.15 / 381.57 6 85
7 13 184.80 20 14.91 653 195 4.34 / 381.76 6 92
8 8 0.04 249 14.91 347 1288 5.63 / 383.05 6 133
Average= 5.32
(KJ/cycle)

Cycle 70 GMT 3/10/2020 23:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 29 15.03 483 211 0.21 / 371.86 6 20
2 10 1000.52 3 15.08 1827 83 0.29 / 371.94 6 48
3 7 2006.00 40 14.63 3074 1799 2.09 / 373.74 48 64
4 13 1977.68 20 14.59 3073 897 2.99 / 374.64 6 66
5 13 1756.96 20 14.54 2805 816 3.80 / 375.45 6 74
6 13 968.40 20 14.66 1725 506 4.31 / 375.96 6 86
7 13 281.68 20 14.85 807 240 4.55 / 376.20 6 93
8 13 12.00 20 14.94 361 108 4.66 / 376.31 6 80
9 8 0.08 223 14.89 337 1119 5.78 / 377.42 6 132
Average= 5.32
(KJ/cycle)

Cycle 69 GMT 24/ 9/2020 2:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 30 15.00 477 215 0.21 / 366.41 6 18
2 3 964.36 -1 15.00 477 0 0.00 / 366.41 6 18
3 7 2003.88 40 14.68 3055 1794 2.01 / 368.20 18 60
4 13 1978.40 20 14.63 3021 884 2.89 / 369.09 6 63
5 13 1420.96 20 14.65 2349 688 3.58 / 369.77 6 76
6 13 979.68 20 14.70 1769 520 4.10 / 370.29 6 84
7 13 126.24 20 14.98 538 161 4.26 / 370.46 6 63
8 13 28.44 20 15.01 373 112 4.37 / 370.57 6 61
9 8 0.00 220 14.97 328 1080 5.45 / 371.65 6 129
Average= 5.31
(KJ/cycle)

Cycle 68 GMT 14/ 9/2020 5:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 30 14.93 512 229 0.23 / 360.83 6 27
2 7 2005.76 40 14.67 3079 1807 2.04 / 362.64 27 65
3 13 1977.28 20 14.63 3068 898 2.93 / 363.53 6 70
4 13 1584.92 20 14.63 2554 747 3.68 / 364.28 6 77
5 13 910.12 20 14.74 1614 476 4.16 / 364.76 6 87
6 13 199.32 20 14.94 661 198 4.35 / 364.95 6 94
7 13 85.20 20 14.97 487 146 4.50 / 365.10 6 92
8 8 0.12 221 14.95 331 1094 5.59 / 366.19 6 134
Average= 5.31
(KJ/cycle)

Cycle 67 GMT 4/ 9/2020 8:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 30 15.03 480 216 0.22 / 355.00 6 15
2 7 2012.92 40 14.64 3086 1807 2.02 / 356.80 15 65
3 13 1984.48 20 14.60 3072 897 2.92 / 357.70 6 67
4 13 1845.28 20 14.55 2898 843 3.76 / 358.54 6 73
5 13 920.24 20 14.69 1668 490 4.25 / 359.03 6 89
6 13 166.36 20 14.90 620 185 4.44 / 359.22 6 93
7 13 26.32 20 14.94 405 121 4.56 / 359.34 6 98
8 8 -0.08 237 14.89 357 1260 5.82 / 360.60 6 133
Average= 5.30
(KJ/cycle)

Cycle 66 GMT 25/ 8/2020 11:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 30 14.96 482 216 0.22 / 349.53 6 17
2 7 2006.20 40 14.67 3067 1800 2.02 / 351.33 17 64
3 13 1980.20 20 14.62 3081 901 2.92 / 352.23 6 67
4 13 1547.68 20 14.62 2497 730 3.65 / 352.96 6 77
5 13 733.88 20 14.78 1409 417 4.06 / 353.38 6 89
6 13 206.68 20 14.96 674 202 4.27 / 353.58 6 78
7 13 28.08 20 15.01 373 112 4.38 / 353.69 6 67
8 8 0.00 220 14.97 330 1087 5.46 / 354.78 6 136
Average= 5.30
(KJ/cycle)

Cycle 65 GMT 15/ 8/2020 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 29 15.00 486 211 0.21 / 344.20 6 15
2 3 1045.48 1 15.09 1904 29 0.24 / 344.23 6 43
3 7 2003.12 40 14.65 3066 1797 2.04 / 346.02 43 63
4 13 1675.72 20 14.66 2661 780 2.82 / 346.80 6 72
5 13 1498.60 20 14.61 2442 714 3.53 / 347.52 6 76
6 13 644.08 20 14.78 1277 377 3.91 / 347.89 6 90
7 13 232.80 20 14.89 715 213 4.12 / 348.11 6 94
8 13 17.96 20 14.96 367 110 4.23 / 348.22 6 85
9 8 -0.08 220 14.91 335 1099 5.33 / 349.32 6 143
Average= 5.29
(KJ/cycle)

Cycle 64 GMT 5/ 8/2020 17:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 31 14.99 480 223 0.22 / 338.66 6 15
2 3 957.08 -1 14.99 480 0 0.00 / 338.66 6 15
3 7 2014.08 40 14.67 3072 1803 2.03 / 340.46 15 60
4 13 1987.68 20 14.62 3064 896 2.92 / 341.36 6 64
5 13 1472.36 20 14.63 2413 706 3.63 / 342.06 6 74
6 13 925.12 20 14.71 1703 501 4.13 / 342.56 6 86
7 13 189.56 20 14.95 636 190 4.32 / 342.75 6 68
8 13 38.88 20 14.99 402 121 4.44 / 342.87 6 62
9 8 0.00 223 14.95 334 1114 5.55 / 343.99 6 136
Average= 5.29
(KJ/cycle)

Cycle 63 GMT 26/ 7/2020 20:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 31 15.00 475 221 0.22 / 333.28 6 17
2 7 2013.40 40 14.66 3047 1787 2.01 / 335.06 17 61
3 13 1983.76 20 14.61 3090 903 2.91 / 335.97 6 67
4 13 1396.16 20 14.64 2287 670 3.58 / 336.63 6 77
5 13 825.32 20 14.73 1529 450 4.03 / 337.09 6 87
6 13 116.36 20 14.96 524 157 4.19 / 337.24 6 70
7 13 24.04 20 14.98 369 111 4.30 / 337.35 6 66
8 8 0.00 220 14.94 329 1081 5.38 / 338.43 6 135
Average= 5.29
(KJ/cycle)

Cycle 62 GMT 16/ 7/2020 23:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 31 14.99 476 221 0.22 / 327.85 6 17
2 7 2012.00 40 14.67 3076 1805 2.03 / 329.66 17 59
3 13 1983.76 20 14.61 3103 907 2.93 / 330.56 6 64
4 13 1361.36 20 14.65 2279 668 3.60 / 331.23 6 76
5 13 872.20 20 14.72 1639 483 4.08 / 331.71 6 85
6 13 88.32 20 14.97 477 143 4.23 / 331.86 6 63
7 13 25.04 20 14.98 376 113 4.34 / 331.97 6 63
8 8 0.08 220 14.94 330 1085 5.42 / 333.05 6 138
Average= 5.29
(KJ/cycle)

Cycle 61 GMT 7/ 7/2020 2:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 30 15.00 504 227 0.23 / 322.36 6 20
2 7 2014.44 40 14.67 3080 1807 2.03 / 324.16 6 58
3 13 1987.52 20 14.62 3100 906 2.94 / 325.07 6 63
4 13 1474.16 20 14.63 2435 712 3.65 / 325.78 6 74
5 13 865.36 20 14.73 1631 480 4.13 / 326.26 6 85
6 13 207.84 20 14.93 667 199 4.33 / 326.46 6 66
7 13 6.80 20 14.99 337 101 4.43 / 326.56 6 63
8 8 0.08 220 14.94 325 1068 5.50 / 327.63 6 139
Average= 5.28
(KJ/cycle)

Cycle 60 GMT 27/ 6/2020 5:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 30 15.00 496 223 0.22 / 316.92 6 22
2 7 2012.60 40 14.65 3180 1863 2.09 / 318.78 6 62
3 13 1981.64 20 14.61 3159 923 3.01 / 319.71 6 64
4 13 1428.20 20 14.64 2371 694 3.70 / 320.40 6 76
5 13 745.96 20 14.78 1477 437 4.14 / 320.84 6 83
6 13 55.00 20 15.01 423 127 4.27 / 320.97 6 61
7 8 0.04 237 14.97 328 1164 5.43 / 322.13 6 136
Average= 5.28
(KJ/cycle)

Cycle 59 GMT 17/ 6/2020 8:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 30 15.03 487 220 0.22 / 311.53 6 19
2 7 2013.20 40 14.67 3125 1834 2.05 / 313.36 6 59
3 13 1984.52 20 14.63 3073 899 2.95 / 314.26 6 62
4 13 1463.28 20 14.64 2404 704 3.66 / 314.97 6 73
5 13 788.92 20 14.77 1531 452 4.11 / 315.42 6 84
6 13 58.96 20 15.01 425 128 4.24 / 315.54 6 62
7 8 0.08 237 14.97 325 1153 5.39 / 316.70 6 131
Average= 5.28
(KJ/cycle)

Cycle 58 GMT 7/ 6/2020 11:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 29 15.04 484 211 0.21 / 305.96 6 22
2 3 1038.24 1 15.11 1886 28 0.24 / 305.99 6 37
3 7 2003.04 40 14.68 3106 1824 2.06 / 307.81 37 59
4 13 1972.00 20 14.62 3145 920 2.98 / 308.73 6 65
5 13 1593.96 20 14.62 2589 757 3.74 / 309.49 6 72
6 13 886.44 20 14.75 1652 487 4.23 / 309.98 6 84
7 13 150.68 20 15.00 571 171 4.40 / 310.15 6 62
8 13 0.96 20 15.04 324 97 4.50 / 310.24 6 65
9 8 -0.12 220 14.98 323 1064 5.56 / 311.31 6 131
Average= 5.28
(KJ/cycle)

Cycle 57 GMT 28/ 5/2020 14:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 31 15.02 505 235 0.24 / 300.51 6 21
2 3 958.56 -1 15.02 505 0 0.00 / 300.51 6 21
3 7 2004.64 40 14.69 3077 1808 2.04 / 302.32 21 60
4 13 1978.28 20 14.64 3082 902 2.95 / 303.22 6 65
5 13 1375.52 20 14.68 2284 671 3.62 / 303.89 6 76
6 13 927.60 20 14.76 1688 498 4.11 / 304.39 6 83
7 13 192.12 20 14.99 646 194 4.31 / 304.59 6 68
8 8 0.12 239 15.00 324 1162 5.47 / 305.75 6 134
Average= 5.27
(KJ/cycle)

Cycle 56 GMT 18/ 5/2020 17:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 31 15.02 511 238 0.24 / 295.07 6 24
2 7 2004.84 41 14.68 3102 1867 2.10 / 296.93 24 59
3 13 1974.20 20 14.64 3065 897 3.00 / 297.83 6 60
4 13 1379.24 20 14.68 2266 665 3.67 / 298.50 6 71
5 13 800.68 20 14.78 1520 449 4.12 / 298.95 6 84
6 13 85.40 20 15.01 478 143 4.26 / 299.09 6 65
7 8 -0.04 237 14.98 335 1189 5.45 / 300.28 6 140
Average= 5.27
(KJ/cycle)

Cycle 55 GMT 8/ 5/2020 20:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 31 15.02 510 237 0.24 / 289.65 6 26
2 7 2015.92 40 14.68 3117 1830 2.07 / 291.48 26 57
3 13 1987.16 20 14.64 3080 902 2.97 / 292.39 6 59
4 13 1340.12 20 14.70 2191 644 3.61 / 293.03 6 71
5 13 750.80 20 14.80 1480 438 4.05 / 293.47 6 80
6 13 164.92 20 14.99 607 182 4.23 / 293.65 6 62
7 8 0.00 237 14.98 332 1179 5.41 / 294.83 6 134
Average= 5.26
(KJ/cycle)

Cycle 54 GMT 28/ 4/2020 23:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 31 15.03 488 227 0.23 / 284.28 6 25
2 7 2003.56 40 14.67 3173 1862 2.09 / 286.14 25 58
3 13 1973.84 20 14.63 3154 923 3.01 / 287.06 6 62
4 13 1290.80 20 14.69 2184 642 3.65 / 287.71 6 72
5 13 703.04 20 14.82 1418 420 4.07 / 288.13 6 79
6 8 0.24 256 15.00 336 1290 5.36 / 289.42 6 135
Average= 5.26
(KJ/cycle)

Cycle 53 GMT 19/ 4/2020 2:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 31 15.04 506 236 0.24 / 278.79 6 23
2 7 2015.36 40 14.70 3059 1799 2.03 / 280.59 6 54
3 13 1985.56 20 14.65 3090 905 2.94 / 281.50 6 58
4 13 1546.80 20 14.65 2498 732 3.67 / 282.23 6 69
5 13 855.96 20 14.78 1622 479 4.15 / 282.71 6 81
6 13 138.64 20 15.01 561 168 4.32 / 282.88 6 58
7 8 0.28 239 15.00 328 1176 5.50 / 284.05 6 132
Average= 5.26
(KJ/cycle)

Cycle 52 GMT 9/ 4/2020 5: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 30 15.04 512 231 0.23 / 273.33 6 22
2 7 2014.00 40 14.69 3135 1842 2.07 / 275.17 6 55
3 13 1983.00 20 14.65 3114 912 2.99 / 276.09 6 59
4 13 1385.72 20 14.69 2292 673 3.66 / 276.76 6 71
5 13 731.36 20 14.82 1476 437 4.10 / 277.20 6 78
6 13 117.20 20 15.03 535 161 4.26 / 277.36 6 58
7 8 0.00 239 15.01 334 1198 5.46 / 278.56 6 143
Average= 5.26
(KJ/cycle)

Cycle 51 GMT 30/ 3/2020 7:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 30 15.04 515 232 0.23 / 267.83 6 29
2 7 2012.32 40 14.69 3176 1866 2.10 / 269.70 6 58
3 13 1980.96 20 14.64 3164 926 3.03 / 270.62 6 61
4 13 1347.20 20 14.70 2247 661 3.69 / 271.29 6 71
5 13 750.68 20 14.83 1492 443 4.13 / 271.73 6 80
6 13 194.08 20 15.01 651 195 4.32 / 271.92 6 61
7 8 0.00 239 15.02 328 1177 5.50 / 273.10 6 151
Average= 5.25
(KJ/cycle)

Cycle 50 GMT 20/ 3/2020 10:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 30 15.05 510 230 0.23 / 262.44 6 29
2 7 2016.16 40 14.71 3074 1809 2.04 / 264.25 29 55
3 13 1986.80 20 14.66 3107 911 2.95 / 265.16 6 61
4 13 1291.52 20 14.72 2170 639 3.59 / 265.80 6 72
5 13 848.72 20 14.80 1610 477 4.07 / 266.27 6 82
6 13 59.40 20 15.06 426 128 4.19 / 266.40 6 61
7 8 0.08 237 15.02 337 1200 5.39 / 267.60 6 136
Average= 5.25
(KJ/cycle)

Cycle 49 GMT 10/ 3/2020 13:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 30 15.06 512 231 0.23 / 256.99 6 29
2 7 2003.28 40 14.71 3132 1843 2.07 / 258.83 29 57
3 13 1971.72 20 14.67 3090 907 2.98 / 259.73 6 60
4 13 1423.44 20 14.71 2325 684 3.66 / 260.42 6 71
5 13 818.56 20 14.82 1565 464 4.13 / 260.88 6 81
6 13 90.72 20 15.06 481 145 4.27 / 261.03 6 61
7 8 0.20 237 15.03 331 1179 5.45 / 262.21 6 136
Average= 5.24
(KJ/cycle)

Cycle 48 GMT 29/ 2/2020 16:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 30 15.05 512 231 0.23 / 251.46 6 28
2 7 2013.96 40 14.70 3144 1849 2.08 / 253.31 28 57
3 13 1983.76 20 14.66 3118 914 2.99 / 254.23 6 61
4 13 1426.60 20 14.71 2335 687 3.68 / 254.91 6 69
5 13 820.68 20 14.82 1568 465 4.15 / 255.38 6 82
6 13 114.56 20 15.05 533 160 4.31 / 255.54 6 63
7 8 -0.08 237 15.03 341 1215 5.52 / 256.75 6 135
Average= 5.24
(KJ/cycle)

Cycle 47 GMT 19/ 2/2020 19:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 30 15.07 512 231 0.23 / 245.94 6 29
2 7 2003.36 41 14.71 3085 1861 2.09 / 247.80 29 59
3 13 1977.40 20 14.66 3131 918 3.01 / 248.72 6 64
4 13 1317.92 20 14.72 2211 651 3.66 / 249.37 6 74
5 13 787.52 20 14.83 1530 454 4.11 / 249.82 6 84
6 13 221.16 20 15.02 691 208 4.32 / 250.03 6 66
7 8 0.04 237 15.03 337 1200 5.52 / 251.23 6 136
Average= 5.23
(KJ/cycle)

Cycle 46 GMT 9/ 2/2020 22:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 30 15.08 512 232 0.23 / 240.50 6 26
2 7 2012.56 40 14.69 3205 1883 2.11 / 242.38 6 59
3 13 1983.24 20 14.65 3168 928 3.04 / 243.31 6 63
4 13 1300.04 20 14.73 2165 638 3.68 / 243.95 6 72
5 13 785.24 20 14.84 1531 454 4.14 / 244.40 6 82
6 8 0.28 256 15.05 340 1310 5.45 / 245.71 6 136
Average= 5.23
(KJ/cycle)

Cycle 45 GMT 31/ 1/2020 1:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 30 15.10 485 220 0.22 / 234.98 6 29
2 7 2012.04 40 14.71 3144 1850 2.07 / 236.83 29 58
3 13 1982.56 20 14.67 3114 914 2.98 / 237.74 6 61
4 13 1577.32 20 14.68 2554 750 3.73 / 238.49 6 70
5 13 743.56 20 14.87 1487 442 4.18 / 238.93 6 82
6 13 91.16 20 15.09 482 145 4.32 / 239.08 6 60
7 8 0.04 237 15.06 332 1185 5.51 / 240.26 6 134
Average= 5.22
(KJ/cycle)

Cycle 44 GMT 21/ 1/2020 4:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 30 15.09 512 232 0.23 / 229.61 6 23
2 7 2013.92 40 14.71 3168 1864 2.10 / 231.47 23 59
3 13 1989.52 20 14.67 3149 924 3.02 / 232.40 6 61
4 13 1308.00 20 14.75 2177 642 3.66 / 233.04 6 72
5 13 872.44 20 14.83 1652 490 4.15 / 233.53 6 82
6 8 0.04 256 15.08 319 1231 5.38 / 234.76 6 139
Average= 5.22
(KJ/cycle)

Cycle 43 GMT 11/ 1/2020 7:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 30 15.10 505 229 0.23 / 224.16 6 22
2 7 2004.80 40 14.73 3075 1812 2.04 / 225.97 22 53
3 13 1977.24 20 14.69 3046 895 2.94 / 226.87 6 57
4 13 1370.16 20 14.74 2258 666 3.60 / 227.53 6 69
5 13 802.92 20 14.85 1548 460 4.06 / 227.99 6 80
6 13 163.40 20 15.06 607 183 4.24 / 228.18 6 63
7 8 0.28 237 15.06 336 1199 5.44 / 229.38 6 134
Average= 5.21
(KJ/cycle)

Cycle 42 GMT 1/ 1/2020 10:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 30 15.09 516 234 0.23 / 218.77 6 23
2 7 2013.60 40 14.72 3134 1845 2.08 / 220.62 6 53
3 13 1986.48 20 14.67 3164 928 3.01 / 221.55 6 59
4 13 1323.16 20 14.75 2223 656 3.66 / 222.20 6 69
5 13 697.44 20 14.90 1411 420 4.08 / 222.62 6 77
6 13 52.44 20 15.11 419 127 4.21 / 222.75 6 56
7 8 -0.12 235 15.07 334 1183 5.39 / 223.93 6 135
Average= 5.21
(KJ/cycle)

Cycle 41 GMT 22/12/2019 13: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 30 15.10 498 226 0.23 / 213.21 6 25
2 7 2009.64 41 14.73 3130 1890 2.12 / 215.10 25 57
3 13 1977.92 20 14.67 3165 929 3.04 / 216.03 6 61
4 13 1292.08 20 14.76 2163 639 3.68 / 216.67 6 72
5 13 868.44 20 14.84 1635 485 4.17 / 217.15 6 82
6 13 133.92 20 15.09 557 168 4.34 / 217.32 6 60
7 8 0.00 237 15.07 341 1218 5.55 / 218.54 6 129
Average= 5.20
(KJ/cycle)

Cycle 40 GMT 12/12/2019 16: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 30 15.12 513 233 0.23 / 207.74 6 21
2 7 2004.76 40 14.72 3157 1859 2.09 / 209.60 6 59
3 13 1976.20 20 14.67 3173 931 3.02 / 210.53 6 62
4 13 1380.24 20 14.74 2305 680 3.70 / 211.21 6 72
5 13 733.08 20 14.89 1463 436 4.14 / 211.65 6 82
6 13 102.28 20 15.10 514 155 4.29 / 211.80 6 62
7 8 0.48 235 15.08 334 1184 5.48 / 212.99 6 134
Average= 5.19
(KJ/cycle)

Cycle 39 GMT 2/12/2019 19: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 30 15.12 498 226 0.23 / 202.16 6 21
2 7 2010.84 40 14.73 3133 1846 2.07 / 204.01 6 57
3 13 1980.08 20 14.68 3173 932 3.00 / 204.94 6 61
4 13 1423.48 20 14.73 2377 700 3.70 / 205.64 6 71
5 13 878.64 20 14.84 1670 496 4.20 / 206.13 6 82
6 13 128.96 20 15.10 555 168 4.37 / 206.30 6 61
7 8 0.00 237 15.08 338 1208 5.57 / 207.51 6 140
Average= 5.19
(KJ/cycle)

Cycle 38 GMT 22/11/2019 21:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 30 15.13 500 227 0.23 / 196.67 6 21
2 7 2003.40 40 14.74 3117 1838 2.06 / 198.50 21 57
3 13 1974.60 20 14.70 3097 911 2.98 / 199.42 6 59
4 13 1433.20 20 14.75 2374 700 3.68 / 200.12 6 71
5 13 772.04 20 14.90 1520 453 4.13 / 200.57 6 81
6 13 97.28 20 15.12 506 153 4.28 / 200.72 6 61
7 8 0.20 237 15.09 339 1212 5.49 / 201.93 6 143
Average= 5.18
(KJ/cycle)

Cycle 37 GMT 13/11/2019 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 30 15.13 485 220 0.22 / 191.09 6 19
2 7 2011.96 40 14.74 3101 1828 2.05 / 192.92 19 57
3 13 1983.04 20 14.69 3109 913 2.96 / 193.83 6 62
4 13 1489.08 20 14.73 2456 724 3.69 / 194.56 6 72
5 13 907.32 20 14.85 1683 500 4.19 / 195.06 6 83
6 13 120.32 20 15.12 550 166 4.35 / 195.22 6 64
7 8 0.00 237 15.10 340 1217 5.57 / 196.44 6 133
Average= 5.17
(KJ/cycle)

Cycle 36 GMT 3/11/2019 3:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 30 15.14 507 230 0.23 / 185.61 6 20
2 7 2004.48 40 14.74 3115 1837 2.07 / 187.45 20 58
3 13 1973.52 20 14.71 3099 912 2.98 / 188.36 6 61
4 13 1414.56 20 14.76 2341 691 3.67 / 189.05 6 72
5 13 770.84 20 14.91 1506 449 4.12 / 189.50 6 84
6 13 71.00 20 15.14 465 141 4.26 / 189.64 6 63
7 8 0.00 240 15.10 339 1229 5.49 / 190.87 6 144
Average= 5.16
(KJ/cycle)

Cycle 35 GMT 24/10/2019 6:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 30 15.13 486 221 0.22 / 180.24 6 19
2 7 2004.44 40 14.76 3060 1807 2.03 / 182.05 19 58
3 13 1974.08 20 14.72 3037 894 2.92 / 182.94 6 61
4 13 1255.20 20 14.80 2133 631 3.55 / 183.57 6 76
5 13 811.60 20 14.89 1565 466 4.02 / 184.04 6 85
6 13 49.68 20 15.14 430 130 4.15 / 184.17 6 62
7 8 0.12 238 15.11 338 1216 5.36 / 185.38 6 149
Average= 5.15
(KJ/cycle)

Cycle 34 GMT 14/10/2019 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 30 15.14 506 230 0.23 / 174.83 6 19
2 7 2005.04 40 14.76 3070 1813 2.04 / 176.64 6 56
3 13 1975.24 20 14.72 3079 906 2.95 / 177.55 6 61
4 13 1353.44 20 14.78 2272 672 3.62 / 178.22 6 74
5 13 717.72 20 14.93 1446 432 4.05 / 178.65 6 83
6 13 102.60 20 15.13 516 156 4.21 / 178.80 6 63
7 8 0.16 237 15.11 339 1214 5.42 / 180.02 6 142
Average= 5.14
(KJ/cycle)

Cycle 33 GMT 4/10/2019 12:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 29 15.14 509 223 0.22 / 169.33 6 20
2 7 2012.64 40 14.75 3129 1846 2.07 / 171.17 6 58
3 13 1981.16 20 14.70 3175 933 3.00 / 172.11 6 63
4 13 1380.72 20 14.78 2281 674 3.68 / 172.78 6 72
5 13 809.12 20 14.90 1566 467 4.14 / 173.25 6 83
6 13 60.44 20 15.15 444 135 4.28 / 173.38 6 62
7 8 0.20 237 15.11 339 1214 5.49 / 174.60 6 138
Average= 5.14
(KJ/cycle)

Cycle 32 GMT 24/ 9/2019 15:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 29 15.17 486 214 0.21 / 163.83 6 15
2 7 2011.76 40 14.74 3173 1871 2.08 / 165.70 6 60
3 13 1982.00 20 14.70 3189 938 3.02 / 166.63 6 63
4 13 1263.12 20 14.81 2142 634 3.66 / 167.27 6 74
5 13 853.60 20 14.89 1625 484 4.14 / 167.75 6 84
6 13 82.40 20 15.15 474 144 4.28 / 167.90 6 64
7 8 -0.08 237 15.12 337 1208 5.49 / 169.10 6 139
Average= 5.12
(KJ/cycle)

Cycle 31 GMT 14/ 9/2019 18:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 29 15.16 489 215 0.21 / 158.39 6 15
2 7 2012.88 40 14.74 3197 1885 2.10 / 160.27 15 60
3 13 1983.36 20 14.70 3168 931 3.03 / 161.20 6 63
4 13 1334.08 20 14.80 2242 664 3.69 / 161.87 6 73
5 13 666.88 20 14.97 1379 413 4.11 / 162.28 6 80
6 13 45.36 20 15.17 425 129 4.24 / 162.41 6 60
7 8 0.16 235 15.13 339 1205 5.44 / 163.61 6 139
Average= 5.11
(KJ/cycle)

Cycle 30 GMT 4/ 9/2019 21:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 29 15.17 495 218 0.22 / 152.89 6 15
2 7 2012.68 40 14.77 3071 1814 2.03 / 154.70 6 56
3 13 1982.00 20 14.71 3159 929 2.96 / 155.63 6 63
4 13 1426.68 20 14.79 2340 692 3.65 / 156.32 6 73
5 13 779.08 20 14.93 1514 452 4.11 / 156.78 6 84
6 13 148.28 20 15.14 592 179 4.28 / 156.96 6 66
7 13 14.00 20 15.17 366 111 4.40 / 157.07 6 64
8 8 0.08 216 15.12 338 1104 5.50 / 158.17 6 133
Average= 5.10
(KJ/cycle)

Cycle 29 GMT 26/ 8/2019 0:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 29 15.17 503 221 0.22 / 147.47 6 16
2 7 2004.16 40 14.77 3084 1822 2.04 / 149.29 16 57
3 13 1975.00 20 14.73 3107 915 2.96 / 150.21 6 62
4 13 1291.24 20 14.83 2160 641 3.60 / 150.85 6 74
5 13 870.88 20 14.90 1661 495 4.09 / 151.35 6 84
6 13 45.04 20 15.18 422 128 4.22 / 151.47 6 61
7 13 9.16 20 15.18 355 108 4.33 / 151.58 6 63
8 8 -0.08 218 15.14 330 1089 5.42 / 152.67 6 146
Average= 5.09
(KJ/cycle)

Cycle 28 GMT 16/ 8/2019 3:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 29 15.18 520 229 0.23 / 142.02 6 16
2 7 2014.44 40 14.76 3187 1882 2.11 / 143.91 6 61
3 13 1984.56 20 14.71 3160 930 3.04 / 144.83 6 62
4 13 1318.52 20 14.83 2184 648 3.69 / 145.48 6 71
5 13 717.16 20 14.97 1453 435 4.12 / 145.92 6 83
6 13 56.44 20 15.18 442 134 4.26 / 146.05 6 62
7 8 0.16 235 15.14 337 1199 5.46 / 147.25 6 137
Average= 5.08
(KJ/cycle)

Cycle 27 GMT 6/ 8/2019 6: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 29 15.19 505 222 0.22 / 136.54 6 17
2 7 2014.48 40 14.78 3105 1836 2.06 / 138.38 6 57
3 13 1984.40 20 14.72 3208 944 3.00 / 139.32 6 64
4 13 1324.84 20 14.82 2235 662 3.67 / 139.99 6 74
5 13 728.44 20 14.97 1466 439 4.10 / 140.43 6 82
6 13 57.20 20 15.19 442 134 4.24 / 140.56 6 62
7 13 11.72 20 15.19 370 112 4.35 / 140.67 6 63
8 8 0.04 216 15.14 343 1122 5.47 / 141.79 6 135
Average= 5.06
(KJ/cycle)

Cycle 26 GMT 27/ 7/2019 8:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 28 15.19 505 215 0.21 / 131.03 6 17
2 3 1020.20 1 15.22 1900 29 0.24 / 131.06 6 10
3 7 2014.96 40 14.79 3116 1843 2.09 / 132.90 10 56
4 13 1985.20 20 14.74 3109 917 3.00 / 133.82 6 62
5 13 1287.56 20 14.85 2169 644 3.65 / 134.46 6 73
6 13 835.88 20 14.93 1618 483 4.13 / 134.94 6 84
7 13 91.24 20 15.18 504 153 4.28 / 135.10 6 63
8 8 0.04 237 15.16 341 1225 5.51 / 136.32 6 140
Average= 5.05
(KJ/cycle)

Cycle 25 GMT 17/ 7/2019 11:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 28 15.19 505 215 0.21 / 125.53 6 19
2 3 1035.28 1 15.19 1903 29 0.24 / 125.56 6 30
3 7 2004.80 40 14.79 3090 1828 2.07 / 127.39 30 57
4 13 1974.48 20 14.75 3059 902 2.97 / 128.29 6 62
5 13 1393.88 20 14.83 2309 685 3.66 / 128.97 6 73
6 13 750.96 20 14.97 1496 448 4.11 / 129.42 6 84
7 13 92.44 20 15.19 509 155 4.26 / 129.58 6 63
8 8 0.12 237 15.16 344 1236 5.50 / 130.81 6 137
Average= 5.03
(KJ/cycle)

Cycle 24 GMT 7/ 7/2019 14:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 29 15.18 504 222 0.22 / 120.02 6 19
2 3 964.92 -1 15.18 504 0 0.00 / 120.02 6 19
3 7 2004.20 41 14.79 3141 1905 2.13 / 121.93 19 60
4 13 1972.84 20 14.74 3157 931 3.06 / 122.86 6 65
5 13 1304.12 20 14.85 2170 644 3.70 / 123.50 6 73
6 13 827.12 20 14.95 1582 473 4.17 / 123.98 6 85
7 13 65.68 20 15.20 456 139 4.31 / 124.12 6 65
8 8 0.12 235 15.16 337 1201 5.51 / 125.32 6 143
Average= 5.01
(KJ/cycle)

Cycle 23 GMT 27/ 6/2019 17:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 29 15.20 507 223 0.22 / 114.54 6 18
2 7 2011.16 40 14.80 3084 1826 2.05 / 116.36 18 58
3 13 1980.48 20 14.75 3104 916 2.96 / 117.28 6 64
4 13 1436.40 20 14.82 2365 701 3.67 / 117.98 6 72
5 13 785.08 20 14.96 1534 459 4.12 / 118.44 6 85
6 13 78.84 20 15.19 481 146 4.27 / 118.58 6 65
7 8 0.00 235 15.16 342 1218 5.49 / 119.80 6 138
Average= 4.99
(KJ/cycle)

Cycle 22 GMT 17/ 6/2019 20:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 29 15.20 511 225 0.23 / 109.13 6 24
2 7 2002.92 41 14.80 3121 1894 2.12 / 111.03 6 58
3 13 1909.16 20 14.77 3060 904 3.02 / 111.93 6 64
4 13 1356.72 20 14.85 2270 674 3.70 / 112.60 6 74
5 13 589.32 20 15.05 1275 384 4.08 / 112.99 6 78
6 13 55.76 20 15.21 439 134 4.21 / 113.12 6 61
7 8 0.16 232 15.18 338 1190 5.40 / 114.31 6 134
Average= 4.97
(KJ/cycle)

Cycle 21 GMT 7/ 6/2019 23:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 29 15.20 509 224 0.22 / 103.81 6 26
2 7 2010.76 40 14.80 3134 1855 2.08 / 105.66 26 59
3 13 1912.80 20 14.77 3090 913 2.99 / 106.58 6 66
4 13 1252.84 20 14.88 2135 635 3.63 / 107.21 6 75
5 13 594.00 20 15.05 1280 385 4.01 / 107.60 6 79
6 13 24.12 20 15.23 384 117 4.13 / 107.71 6 62
7 8 0.12 232 15.18 339 1194 5.32 / 108.91 6 132
Average= 4.95
(KJ/cycle)

Cycle 20 GMT 29/ 5/2019 1:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 29 15.20 509 224 0.22 / 98.44 6 27
2 7 2005.00 40 14.81 3132 1855 2.08 / 100.30 27 58
3 13 1917.92 20 14.77 3063 905 2.98 / 101.20 6 66
4 13 1170.48 20 14.90 2029 605 3.59 / 101.81 6 77
5 13 741.44 20 15.00 1490 447 4.04 / 102.25 6 83
6 13 35.40 20 15.23 408 124 4.16 / 102.38 6 63
7 8 0.00 232 15.18 342 1204 5.36 / 103.58 6 133
Average= 4.93
(KJ/cycle)

Cycle 19 GMT 19/ 5/2019 4:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 29 15.21 522 230 0.23 / 92.98 6 29
2 7 2008.24 40 14.81 3144 1863 2.09 / 94.85 6 59
3 13 1922.04 20 14.78 3059 904 3.00 / 95.75 6 65
4 13 1362.32 20 14.86 2284 679 3.68 / 96.43 6 74
5 13 694.28 20 15.02 1430 430 4.11 / 96.86 6 83
6 13 53.88 20 15.22 437 133 4.24 / 96.99 6 64
7 8 0.04 235 15.19 344 1228 5.47 / 98.22 6 151
Average= 4.91
(KJ/cycle)

Cycle 18 GMT 9/ 5/2019 7: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 29 15.21 515 227 0.23 / 87.48 6 30
2 7 2005.56 41 14.82 3119 1895 2.12 / 89.38 6 59
3 13 1913.72 20 14.78 3074 909 3.03 / 90.29 6 65
4 13 1368.52 20 14.86 2273 676 3.71 / 90.96 6 73
5 13 791.64 20 14.99 1545 463 4.17 / 91.42 6 84
6 13 17.48 20 15.24 379 116 4.29 / 91.54 6 63
7 8 0.04 232 15.19 344 1212 5.50 / 92.75 6 135
Average= 4.88
(KJ/cycle)

Cycle 17 GMT 29/ 4/2019 9:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 29 15.22 520 230 0.23 / 82.12 6 31
2 7 2013.36 40 14.82 3121 1850 2.08 / 83.97 6 57
3 13 1818.16 20 14.82 2893 857 2.94 / 84.83 6 66
4 13 1492.36 20 14.83 2472 733 3.67 / 85.56 6 73
5 13 587.24 20 15.07 1279 385 4.06 / 85.95 6 79
6 8 0.12 254 15.20 338 1305 5.36 / 87.25 6 142
Average= 4.85
(KJ/cycle)

Cycle 16 GMT 19/ 4/2019 12:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 29 15.22 506 223 0.22 / 76.78 6 33
2 7 2005.36 40 14.80 3214 1903 2.13 / 78.69 33 61
3 13 1914.72 20 14.79 3084 912 3.04 / 79.60 6 65
4 13 1258.88 20 14.90 2139 637 3.68 / 80.24 6 76
5 13 501.04 20 15.11 1139 344 4.02 / 80.58 6 75
6 8 0.24 251 15.21 344 1313 5.33 / 81.89 6 138
Average= 4.82
(KJ/cycle)

Cycle 15 GMT 9/ 4/2019 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 29 15.22 529 233 0.23 / 71.44 6 34
2 7 2010.24 40 14.82 3127 1854 2.09 / 73.30 34 58
3 13 1712.24 20 14.84 2755 818 2.90 / 74.12 6 68
4 13 1503.88 20 14.84 2480 736 3.64 / 74.85 6 72
5 13 589.20 20 15.07 1276 385 4.03 / 75.24 6 80
6 8 0.04 251 15.21 347 1325 5.35 / 76.56 6 138
Average= 4.79
(KJ/cycle)

Cycle 14 GMT 30/ 3/2019 17:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 29 15.22 536 237 0.24 / 66.11 6 34
2 7 2004.08 40 14.84 3077 1827 2.06 / 67.93 34 58
3 13 1916.68 20 14.82 2996 888 2.95 / 68.82 6 63
4 13 1250.40 20 14.91 2134 636 3.59 / 69.46 6 77
5 13 697.28 20 15.04 1438 433 4.02 / 69.89 6 84
6 8 0.20 251 15.21 346 1321 5.34 / 71.21 6 132
Average= 4.75
(KJ/cycle)

Cycle 13 GMT 20/ 3/2019 20:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 29 15.23 519 229 0.23 / 60.66 6 34
2 7 2009.72 40 14.84 3105 1843 2.07 / 62.50 34 59
3 13 1916.08 20 14.81 3055 905 2.98 / 63.40 6 64
4 13 1277.44 20 14.90 2160 644 3.62 / 64.05 6 76
5 13 727.08 20 15.03 1467 441 4.06 / 64.49 6 84
6 13 60.68 20 15.24 453 138 4.20 / 64.63 6 65
7 13 32.48 20 15.24 414 126 4.33 / 64.75 6 67
8 8 0.04 211 15.20 348 1116 5.44 / 65.87 6 130
Average= 4.70
(KJ/cycle)

Cycle 12 GMT 10/ 3/2019 22:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 29 15.23 522 231 0.23 / 55.30 6 33
2 7 2004.32 40 14.84 3149 1869 2.10 / 57.17 33 59
3 13 1913.20 20 14.82 3040 901 3.00 / 58.07 6 65
4 13 1255.84 20 14.92 2140 639 3.64 / 58.71 6 76
5 13 597.20 20 15.08 1290 389 4.03 / 59.10 6 80
6 8 0.20 251 15.22 348 1329 5.36 / 60.43 6 132
Average= 4.65
(KJ/cycle)

Cycle 11 GMT 1/ 3/2019 1:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 29 15.24 529 234 0.23 / 49.75 6 34
2 7 2013.84 41 14.82 3248 1974 2.21 / 51.72 34 61
3 13 1916.60 20 14.82 3104 920 3.13 / 52.64 6 66
4 13 1244.04 20 14.93 2140 639 3.77 / 53.28 6 76
5 13 688.00 20 15.06 1428 430 4.20 / 53.71 6 81
6 8 0.12 254 15.23 351 1358 5.55 / 55.07 6 149
Average= 4.59
(KJ/cycle)

Cycle 10 GMT 19/ 2/2019 4: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 28 15.24 523 223 0.22 / 44.35 6 32
2 7 2005.04 40 14.86 3105 1846 2.07 / 46.20 6 57
3 13 1917.76 20 14.82 3092 916 2.99 / 47.11 6 65
4 13 1274.44 20 14.92 2181 651 3.64 / 47.76 6 76
5 13 621.20 20 15.09 1345 406 4.04 / 48.17 6 80
6 13 26.84 20 15.27 405 124 4.17 / 48.29 6 64
7 8 0.04 228 15.22 352 1221 5.39 / 49.52 6 133
Average= 4.50
(KJ/cycle)

Cycle 9 GMT 9/ 2/2019 6:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 28 15.25 524 224 0.22 / 38.90 6 32
2 7 2004.32 40 14.84 3209 1905 2.13 / 40.80 6 60
3 13 1914.96 20 14.83 3023 897 3.03 / 41.70 6 64
4 13 1372.20 20 14.90 2304 687 3.71 / 42.38 6 74
5 13 601.32 20 15.10 1300 393 4.10 / 42.78 6 78
6 13 12.04 20 15.28 371 113 4.22 / 42.89 6 62
7 8 0.16 235 15.23 346 1238 5.46 / 44.13 6 140
Average= 4.41
(KJ/cycle)

Cycle 8 GMT 30/ 1/2019 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 28 15.26 520 222 0.22 / 33.64 6 31
2 7 2009.16 40 14.86 3118 1853 2.08 / 35.49 6 59
3 13 1925.72 20 14.83 3077 913 2.99 / 36.40 6 66
4 13 1175.64 20 14.95 2036 609 3.60 / 37.01 6 79
5 13 534.84 20 15.13 1197 362 3.96 / 37.37 6 75
6 8 0.00 249 15.24 342 1298 5.26 / 38.67 6 133
Average= 4.30
(KJ/cycle)

Cycle 7 GMT 20/ 1/2019 11:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 27 15.26 531 219 0.22 / 28.34 6 31
2 7 2012.28 40 14.85 3213 1909 2.13 / 30.25 6 63
3 13 1819.92 20 14.86 2906 864 2.99 / 31.12 6 67
4 13 1177.08 20 14.95 2042 611 3.60 / 31.73 6 79
5 13 537.52 20 15.13 1205 365 3.97 / 32.09 6 78
6 8 0.20 249 15.24 349 1324 5.29 / 33.41 6 129
Average= 4.18
(KJ/cycle)

Cycle 6 GMT 10/ 1/2019 14:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 26 15.26 525 208 0.21 / 22.99 6 30
2 3 1053.92 1 15.23 1934 29 0.24 / 23.02 6 48
3 7 2003.52 40 14.86 3157 1877 2.11 / 24.89 48 62
4 13 1908.12 20 14.86 3005 893 3.01 / 25.79 6 66
5 13 1231.64 20 14.96 2087 624 3.63 / 26.41 6 78
6 13 581.52 20 15.11 1273 385 4.02 / 26.79 6 81
7 13 46.72 20 15.28 427 130 4.15 / 26.93 6 66
8 8 -0.04 230 15.24 342 1199 5.35 / 28.12 6 130
Average= 4.02
(KJ/cycle)

Cycle 5 GMT 31/12/2018 17: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 31 15.27 510 241 0.24 / 17.83 6 31
2 3 836.00 -3 15.27 510 0 0.00 / 17.83 6 31
3 7 2009.00 40 14.88 3101 1846 2.09 / 19.67 31 60
4 13 1817.76 20 14.87 2906 864 2.95 / 20.54 6 67
5 13 1173.60 20 14.97 2022 605 3.56 / 21.14 6 79
6 13 422.52 20 15.17 1029 312 3.87 / 21.45 6 77
7 8 0.12 249 15.25 349 1325 5.19 / 22.78 6 132
Average= 3.80
(KJ/cycle)

Cycle 4 GMT 21/12/2018 19:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 27 15.27 501 207 0.21 / 13.32 6 31
2 7 1519.16 40 15.03 2547 1531 1.74 / 14.85 6 70
3 13 1439.72 20 15.01 2419 726 2.46 / 15.57 6 73
4 13 919.68 20 15.07 1715 517 2.98 / 16.09 6 82
5 13 269.68 20 15.25 779 238 3.22 / 16.33 6 72
6 8 0.12 242 15.27 340 1256 4.47 / 17.58 6 129
Average= 3.52
(KJ/cycle)

Cycle 3 GMT 20/12/2018 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 26 15.27 500 199 0.20 / 8.90 6 30
2 7 1504.20 40 15.03 2564 1541 1.74 / 10.44 6 70
3 13 1423.16 20 15.02 2430 730 2.47 / 11.17 6 74
4 13 809.56 20 15.10 1584 478 2.95 / 11.65 6 84
5 13 166.20 20 15.28 617 189 3.14 / 11.84 6 68
6 8 0.16 242 15.27 343 1268 4.40 / 13.11 6 131
Average= 3.28
(KJ/cycle)

Cycle 2 GMT 18/12/2018 22:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 31 15.27 486 230 0.23 / 4.56 6 31
2 3 809.32 -3 15.27 486 0 0.00 / 4.56 6 31
3 7 1457.08 40 15.06 2467 1486 1.72 / 6.05 31 67
4 13 1374.52 20 15.04 2341 704 2.42 / 6.75 6 70
5 13 857.36 20 15.10 1633 493 2.91 / 7.25 6 82
6 13 207.32 20 15.27 685 209 3.12 / 7.46 6 69
7 8 0.00 239 15.27 342 1248 4.37 / 8.71 6 129
Average= 2.90
(KJ/cycle)

Cycle 1 GMT 17/12/2018 11:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 31 15.34 473 225 0.22 / 1.91 6 29
2 3 798.72 -3 15.34 473 0 0.00 / 1.91 6 29
3 7 920.16 40 15.17 1734 1052 1.28 / 2.96 29 67
4 13 147.84 20 15.32 576 176 1.45 / 3.13 6 63
5 8 0.16 242 15.30 324 1200 2.65 / 4.33 6 141
Average= 2.17
(KJ/cycle)

Cycle 0 GMT 17/12/2018 1:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 70.40 30 15.49 435 202 0.20 / 0.20 6 37
2 7 80.36 40 15.47 440 272 0.47 / 0.47 37 41
3 13 6.40 20 15.46 323 100 0.57 / 0.57 6 43
4 8 0.04 237 15.41 303 1107 1.68 / 1.68 6 176
Average= 1.68
(KJ/cycle)