SIO Argo Site:
Pump Diagnostics Page   



Serial= 8774 WMO= 4903017

Return

←PreviousNext→

Cycle 208 GMT 16/12/2024 14:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 32 14.93 451 215 0.22 / 851.60 2 3
2 3 1020.96 1 14.98 1873 28 0.24 / 851.63 2 4
3 7 2004.52 30 14.66 3082 1355 1.60 / 852.98 2 4
4 13 1597.16 20 14.64 2571 753 2.35 / 853.74 2 5
5 13 1010.08 20 14.71 1793 528 2.88 / 854.27 2 6
6 13 568.52 20 14.80 1177 348 3.23 / 854.61 2 7
7 13 57.20 20 14.97 386 116 3.34 / 854.73 2 3
8 8 -0.16 165 14.95 306 755 4.10 / 855.48 2 3
9 14 -0.16 30 14.93 306 137 4.24 / 855.62 2 5
Average= 4.09
(KJ/cycle)

Cycle 207 GMT 6/12/2024 18:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 32 14.93 453 216 0.22 / 847.53 2 2
2 7 2005.72 31 14.66 3085 1402 1.62 / 848.93 2 5
3 13 1590.84 20 14.64 2571 753 2.37 / 849.68 2 5
4 13 1009.48 20 14.71 1797 529 2.90 / 850.21 2 6
5 13 447.80 20 14.85 1004 298 3.20 / 850.51 2 8
6 13 65.64 20 14.97 397 119 3.32 / 850.63 2 3
7 8 0.12 165 14.95 308 760 4.08 / 851.39 2 4
Average= 4.09
(KJ/cycle)

Cycle 206 GMT 26/11/2024 23:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 32 14.93 459 219 0.22 / 843.45 2 3
2 7 2010.44 30 14.66 3097 1362 1.58 / 844.81 2 4
3 13 1610.40 20 14.64 2595 760 2.34 / 845.57 2 4
4 13 1052.96 20 14.69 1856 545 2.89 / 846.12 2 7
5 13 478.92 20 14.83 1054 313 3.20 / 846.43 2 7
6 13 50.08 20 14.97 384 115 3.31 / 846.55 2 3
7 8 -0.08 165 14.95 309 762 4.08 / 847.31 2 3
Average= 4.09
(KJ/cycle)

Cycle 205 GMT 17/11/2024 4: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 32 14.93 443 212 0.21 / 839.31 2 3
2 3 1025.88 1 14.96 1893 28 0.24 / 839.34 2 4
3 7 2011.68 30 14.68 3094 1363 1.60 / 840.70 2 4
4 13 1610.80 20 14.64 2592 759 2.36 / 841.46 2 5
5 13 1035.28 20 14.70 1834 539 2.90 / 842.00 2 6
6 13 583.88 20 14.80 1205 357 3.26 / 842.36 2 7
7 13 60.04 20 14.97 391 117 3.37 / 842.47 2 3
8 8 0.00 165 14.95 308 760 4.13 / 843.23 2 3
Average= 4.09
(KJ/cycle)

Cycle 204 GMT 7/11/2024 8:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 32 14.94 459 219 0.22 / 835.22 2 2
2 7 2010.12 30 14.66 3083 1356 1.58 / 836.58 2 5
3 13 1603.44 20 14.64 2574 754 2.33 / 837.33 2 5
4 13 1033.00 20 14.70 1830 538 2.87 / 837.87 2 6
5 13 585.32 20 14.80 1205 357 3.22 / 838.23 2 7
6 13 54.84 20 14.97 384 115 3.34 / 838.34 2 3
7 8 -0.04 165 14.95 306 755 4.09 / 839.10 2 4
Average= 4.09
(KJ/cycle)

Cycle 203 GMT 28/10/2024 13: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 32 14.94 451 216 0.22 / 831.17 2 3
2 7 2005.04 30 14.67 3088 1359 1.57 / 832.53 2 5
3 13 1502.28 20 14.66 2449 718 2.29 / 833.25 2 6
4 13 1088.16 20 14.69 1904 559 2.85 / 833.81 2 6
5 13 508.84 20 14.82 1097 325 3.18 / 834.13 2 8
6 13 47.12 20 14.97 374 112 3.29 / 834.24 2 3
7 8 0.20 165 14.95 309 762 4.05 / 835.01 2 3
Average= 4.09
(KJ/cycle)

Cycle 202 GMT 18/10/2024 17:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 31 14.94 450 208 0.21 / 826.86 2 3
2 10 1006.92 2 14.94 1836 55 0.26 / 826.92 2 5
3 3 969.44 -1 15.26 0 0 0.05 / 826.92 2 5
4 7 2004.68 30 14.67 3080 1356 1.62 / 828.27 2 4
5 13 1745.72 20 14.62 2759 807 2.43 / 829.08 2 5
6 13 1141.16 20 14.68 1971 579 3.00 / 829.66 2 7
7 13 545.80 20 14.82 1148 340 3.34 / 830.00 2 8
8 13 56.00 20 14.98 382 114 3.46 / 830.11 2 3
9 13 17.80 20 14.99 324 97 3.56 / 830.21 2 2
10 8 0.00 165 14.96 302 745 4.30 / 830.95 2 3
Average= 4.09
(KJ/cycle)

Cycle 201 GMT 8/10/2024 22:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 31 14.94 474 220 0.22 / 822.62 2 3
2 3 977.24 -1 15.27 0 0 0.00 / 822.62 2 3
3 7 2003.88 30 14.67 3075 1353 1.57 / 823.97 2 4
4 13 1744.64 20 14.62 2764 808 2.38 / 824.78 2 5
5 13 1123.80 20 14.69 1950 573 2.95 / 825.35 2 7
6 13 528.04 20 14.82 1122 333 3.29 / 825.69 2 7
7 13 52.92 20 14.98 380 114 3.40 / 825.80 2 3
8 13 31.12 20 14.98 336 101 3.50 / 825.90 2 2
9 8 0.04 165 14.95 305 752 4.25 / 826.65 2 3
Average= 4.09
(KJ/cycle)

Cycle 200 GMT 29/ 9/2024 3: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 30 14.95 452 203 0.20 / 818.34 2 2
2 3 1027.64 1 14.97 1899 28 0.23 / 818.37 2 5
3 7 2005.24 30 14.67 3074 1353 1.58 / 819.72 2 3
4 13 1742.96 20 14.62 2751 804 2.39 / 820.53 2 5
5 13 1117.76 20 14.69 1936 569 2.96 / 821.10 2 7
6 13 543.24 20 14.82 1149 341 3.30 / 821.44 2 8
7 13 52.40 20 14.98 379 114 3.41 / 821.55 2 3
8 13 15.88 20 14.98 325 97 3.51 / 821.65 2 2
9 8 -0.04 165 14.95 305 752 4.26 / 822.40 2 4
Average= 4.09
(KJ/cycle)

Cycle 199 GMT 19/ 9/2024 7:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 31 14.96 455 211 0.21 / 814.32 2 3
2 3 969.92 -1 15.28 0 0 0.00 / 814.32 2 3
3 7 2002.28 30 14.67 3084 1357 1.57 / 815.68 2 5
4 13 1600.64 20 14.65 2577 755 2.32 / 816.43 2 6
5 13 1035.36 20 14.70 1826 537 2.86 / 816.97 2 6
6 13 466.56 20 14.85 1031 306 3.17 / 817.27 2 8
7 13 38.64 20 14.98 360 108 3.27 / 817.38 2 2
8 8 -0.08 165 14.96 306 755 4.03 / 818.14 2 3
Average= 4.09
(KJ/cycle)

Cycle 198 GMT 9/ 9/2024 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 31 14.93 473 219 0.22 / 810.00 2 3
2 7 2010.92 30 14.67 3100 1364 1.58 / 811.36 2 4
3 13 1749.52 20 14.62 2775 811 2.39 / 812.17 2 5
4 13 1021.12 20 14.71 1816 534 2.93 / 812.71 2 6
5 13 473.92 20 14.85 1040 309 3.24 / 813.02 2 8
6 13 46.72 20 14.98 370 111 3.35 / 813.13 2 3
7 13 19.48 20 14.99 326 98 3.45 / 813.23 2 2
8 8 0.12 165 14.96 303 748 4.19 / 813.97 2 4
9 14 0.12 30 14.94 300 134 4.33 / 814.11 2 4
Average= 4.09
(KJ/cycle)

Cycle 197 GMT 30/ 8/2024 16:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 31 14.94 449 208 0.21 / 805.68 2 3
2 3 1031.96 1 14.97 1894 28 0.24 / 805.71 2 4
3 7 2006.60 31 14.66 3087 1403 1.64 / 807.11 2 4
4 13 1743.36 20 14.62 2757 806 2.45 / 807.92 2 6
5 13 1119.04 20 14.69 1942 571 3.02 / 808.49 2 7
6 13 515.40 20 14.83 1106 328 3.34 / 808.81 2 8
7 13 45.44 20 14.98 369 111 3.45 / 808.93 2 3
8 13 13.88 20 14.99 323 97 3.55 / 809.02 2 2
9 8 0.00 165 14.95 307 757 4.31 / 809.78 2 3
Average= 4.09
(KJ/cycle)

Cycle 196 GMT 20/ 8/2024 21: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 31 14.95 452 209 0.21 / 801.65 2 3
2 7 2007.72 30 14.66 3089 1359 1.57 / 803.01 2 4
3 13 1602.04 20 14.64 2577 755 2.32 / 803.76 2 6
4 13 1038.68 20 14.71 1831 539 2.86 / 804.30 2 6
5 13 471.04 20 14.85 1038 308 3.17 / 804.61 2 7
6 13 44.16 20 14.98 369 111 3.28 / 804.72 2 3
7 8 -0.08 165 14.96 304 750 4.03 / 805.47 2 3
Average= 4.09
(KJ/cycle)

Cycle 195 GMT 11/ 8/2024 1:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 31 14.94 459 213 0.21 / 797.41 2 3
2 7 2004.36 30 14.68 3093 1362 1.57 / 798.77 2 4
3 13 1727.72 20 14.63 2742 802 2.38 / 799.58 2 5
4 13 1118.20 20 14.69 1934 568 2.95 / 800.14 2 6
5 13 527.04 20 14.83 1124 333 3.28 / 800.48 2 7
6 13 55.44 20 14.98 383 115 3.39 / 800.59 2 3
7 13 18.16 20 14.99 328 98 3.49 / 800.69 2 2
8 8 0.12 165 14.96 304 750 4.24 / 801.44 2 3
Average= 4.09
(KJ/cycle)

Cycle 194 GMT 1/ 8/2024 6: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 32 14.95 485 232 0.23 / 793.04 2 2
2 3 959.72 -1 15.27 0 0 0.00 / 793.04 2 2
3 7 2003.04 30 14.67 3083 1357 1.59 / 794.39 2 4
4 13 1734.32 20 14.63 2733 800 2.39 / 795.19 2 6
5 13 1123.60 20 14.69 1946 572 2.96 / 795.76 2 7
6 13 535.84 20 14.83 1133 336 3.30 / 796.10 2 6
7 13 48.08 20 14.99 373 112 3.41 / 796.21 2 3
8 13 16.68 20 14.99 328 98 3.51 / 796.31 2 2
9 8 0.00 165 14.96 305 753 4.26 / 797.06 2 3
10 14 0.00 30 14.94 303 136 4.40 / 797.20 2 10
Average= 4.09
(KJ/cycle)

Cycle 193 GMT 22/ 7/2024 10:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 32 14.94 460 220 0.22 / 789.06 2 3
2 7 2004.56 30 14.67 3083 1357 1.58 / 790.42 2 4
3 13 1498.80 20 14.65 2446 717 2.29 / 791.13 2 5
4 13 962.48 20 14.72 1728 509 2.80 / 791.64 2 6
5 13 414.84 20 14.87 952 283 3.09 / 791.93 2 8
6 13 55.56 20 14.98 381 114 3.20 / 792.04 2 3
7 8 0.12 165 14.96 309 763 3.96 / 792.80 2 3
Average= 4.09
(KJ/cycle)

Cycle 192 GMT 12/ 7/2024 15:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 32 14.94 458 219 0.22 / 785.04 2 3
2 7 2006.80 30 14.66 3080 1355 1.57 / 786.39 2 4
3 13 1595.04 20 14.64 2561 750 2.32 / 787.14 2 6
4 13 1021.32 20 14.72 1809 533 2.86 / 787.67 2 7
5 13 456.64 20 14.86 1019 303 3.16 / 787.98 2 7
6 13 33.68 20 14.99 352 106 3.26 / 788.08 2 2
7 8 0.12 165 14.96 308 760 4.02 / 788.84 2 3
Average= 4.09
(KJ/cycle)

Cycle 191 GMT 2/ 7/2024 19:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 32 14.94 459 219 0.22 / 780.94 2 3
2 3 969.72 -1 15.27 0 0 0.00 / 780.94 2 3
3 7 2006.96 30 14.67 3089 1359 1.58 / 782.30 2 4
4 13 1586.40 20 14.65 2554 748 2.33 / 783.05 2 6
5 13 1020.52 20 14.71 1810 533 2.86 / 783.59 2 6
6 13 571.36 20 14.82 1185 351 3.21 / 783.94 2 7
7 13 54.20 20 14.98 383 115 3.33 / 784.05 2 3
8 8 0.08 165 14.96 310 765 4.09 / 784.82 2 5
Average= 4.09
(KJ/cycle)

Cycle 190 GMT 23/ 6/2024 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 32 14.94 459 219 0.22 / 776.83 2 3
2 7 2009.36 30 14.67 3098 1363 1.58 / 778.20 2 4
3 13 1616.36 20 14.64 2597 760 2.34 / 778.96 2 5
4 13 1049.20 20 14.71 1846 543 2.89 / 779.50 2 6
5 13 597.40 20 14.81 1224 363 3.25 / 779.86 2 7
6 13 34.32 20 14.99 352 106 3.35 / 779.97 2 2
7 8 0.08 165 14.97 307 758 4.11 / 780.73 2 3
Average= 4.09
(KJ/cycle)

Cycle 189 GMT 13/ 6/2024 4:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 32 14.94 454 217 0.22 / 772.78 2 3
2 7 2010.24 30 14.67 3096 1363 1.58 / 774.15 2 4
3 13 1595.16 20 14.65 2568 752 2.33 / 774.90 2 5
4 13 1016.64 20 14.72 1805 531 2.86 / 775.43 2 6
5 13 448.00 20 14.86 1003 298 3.16 / 775.73 2 7
6 13 67.36 20 14.98 398 119 3.28 / 775.85 2 3
7 8 0.08 165 14.96 310 765 4.05 / 776.61 2 3
Average= 4.09
(KJ/cycle)

Cycle 188 GMT 3/ 6/2024 9:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 31 14.94 458 212 0.21 / 768.70 2 3
2 10 1001.08 3 14.94 1815 81 0.29 / 768.78 2 4
3 3 970.08 -1 15.26 0 0 0.08 / 768.78 2 4
4 7 2011.52 30 14.66 3093 1360 1.65 / 770.14 2 4
5 13 1475.56 20 14.67 2413 708 2.36 / 770.85 2 6
6 13 1045.16 20 14.71 1850 544 2.91 / 771.39 2 6
7 13 460.24 20 14.85 1024 304 3.21 / 771.70 2 8
8 13 35.32 20 14.99 351 105 3.32 / 771.80 2 2
9 8 0.04 165 14.97 310 766 4.08 / 772.57 2 5
Average= 4.09
(KJ/cycle)

Cycle 187 GMT 24/ 5/2024 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.48 32 14.94 496 237 0.24 / 764.62 2 3
2 3 959.24 -1 15.26 0 0 0.00 / 764.62 2 3
3 7 2005.08 31 14.67 3084 1403 1.64 / 766.03 2 4
4 13 1600.36 20 14.65 2578 755 2.39 / 766.78 2 5
5 13 1022.72 20 14.72 1813 534 2.93 / 767.32 2 7
6 13 456.20 20 14.86 1021 303 3.23 / 767.62 2 6
7 13 31.40 20 15.00 343 103 3.34 / 767.72 2 2
8 8 0.04 165 14.97 309 763 4.10 / 768.49 2 3
Average= 4.09
(KJ/cycle)

Cycle 186 GMT 14/ 5/2024 18:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 31 14.95 462 214 0.21 / 760.41 2 3
2 10 1001.04 3 14.94 1814 81 0.30 / 760.49 2 6
3 3 958.36 -1 15.26 0 0 0.08 / 760.49 2 6
4 3 980.88 -1 15.30 0 0 0.08 / 760.49 2 6
5 7 2008.56 30 14.67 3091 1360 1.66 / 761.86 2 4
6 13 1608.60 20 14.65 2581 756 2.41 / 762.61 2 6
7 13 1027.24 20 14.72 1823 537 2.95 / 763.15 2 7
8 13 577.04 20 14.82 1200 356 3.30 / 763.50 2 7
9 13 55.12 20 14.99 385 115 3.42 / 763.62 2 3
10 8 0.00 165 14.97 311 768 4.19 / 764.39 2 4
Average= 4.09
(KJ/cycle)

Cycle 185 GMT 4/ 5/2024 23:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 31 14.93 497 230 0.23 / 756.39 2 3
2 7 2004.64 30 14.67 3088 1359 1.59 / 757.75 2 4
3 13 1601.20 20 14.65 2581 756 2.35 / 758.51 2 6
4 13 1013.52 20 14.73 1804 531 2.88 / 759.04 2 6
5 13 447.24 20 14.86 1003 298 3.17 / 759.34 2 8
6 13 16.24 20 15.00 328 98 3.27 / 759.44 2 2
7 8 0.24 165 14.97 309 763 4.04 / 760.20 2 3
Average= 4.09
(KJ/cycle)

Cycle 184 GMT 25/ 4/2024 4:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.80 32 14.94 495 237 0.24 / 752.32 2 3
2 3 975.84 -1 15.26 0 0 0.00 / 752.32 2 3
3 7 2009.04 30 14.67 3095 1362 1.60 / 753.68 2 5
4 13 1605.12 20 14.65 2586 758 2.36 / 754.44 2 5
5 13 1031.40 20 14.72 1828 538 2.89 / 754.98 2 6
6 13 450.20 20 14.86 1015 302 3.20 / 755.28 2 8
7 13 34.52 20 15.00 353 106 3.30 / 755.39 2 2
8 8 0.20 165 14.97 314 776 4.08 / 756.16 2 3
Average= 4.09
(KJ/cycle)

Cycle 183 GMT 15/ 4/2024 8:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 32 14.93 492 235 0.24 / 748.14 2 3
2 7 2003.84 30 14.67 3084 1357 1.59 / 749.50 2 5
3 13 1722.52 20 14.64 2741 803 2.39 / 750.30 2 5
4 13 1132.20 20 14.70 1957 575 2.97 / 750.88 2 6
5 13 533.36 20 14.84 1132 336 3.31 / 751.21 2 7
6 13 27.32 20 15.01 337 101 3.41 / 751.31 2 2
7 8 -0.24 165 14.97 312 771 4.18 / 752.09 2 3
Average= 4.09
(KJ/cycle)

Cycle 182 GMT 5/ 4/2024 13:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 32 14.93 494 236 0.24 / 743.97 2 3
2 7 2012.12 30 14.66 3093 1360 1.60 / 745.33 2 5
3 13 1599.04 20 14.66 2574 755 2.35 / 746.09 2 6
4 13 1155.12 20 14.69 1985 583 2.93 / 746.67 2 7
5 13 526.40 20 14.84 1128 335 3.27 / 747.01 2 7
6 13 23.56 20 15.00 340 102 3.37 / 747.11 2 2
7 8 0.20 165 14.97 323 798 4.17 / 747.91 2 2
Average= 4.09
(KJ/cycle)

Cycle 181 GMT 26/ 3/2024 18:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 34 14.93 492 250 0.25 / 739.92 2 3
2 3 953.44 -2 15.26 0 0 0.00 / 739.92 2 3
3 7 2009.00 30 14.67 3077 1354 1.60 / 741.28 2 4
4 13 1592.08 20 14.66 2570 754 2.36 / 742.03 2 5
5 13 1020.80 20 14.72 1808 532 2.89 / 742.56 2 7
6 13 456.92 20 14.86 1025 305 3.19 / 742.87 2 8
7 13 16.08 20 15.00 335 100 3.29 / 742.97 2 2
8 8 0.32 165 14.97 311 768 4.06 / 743.74 2 2
Average= 4.09
(KJ/cycle)

Cycle 180 GMT 16/ 3/2024 23:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 32 14.94 465 222 0.22 / 735.76 2 3
2 10 1008.12 3 14.93 1821 82 0.30 / 735.84 2 4
3 7 2009.76 30 14.67 3096 1363 1.67 / 737.20 2 4
4 13 1604.76 20 14.65 2591 759 2.43 / 737.96 2 5
5 13 1013.00 20 14.73 1798 530 2.96 / 738.49 2 6
6 13 442.64 20 14.87 1002 298 3.25 / 738.79 2 7
7 13 28.96 20 15.00 351 105 3.36 / 738.89 2 2
8 8 -0.12 165 14.97 316 781 4.14 / 739.68 2 3
Average= 4.09
(KJ/cycle)

Cycle 179 GMT 7/ 3/2024 4:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 32 14.93 503 240 0.24 / 731.57 2 3
2 7 2010.76 30 14.68 3084 1358 1.60 / 732.93 2 4
3 13 1748.08 20 14.64 2761 808 2.41 / 733.74 2 6
4 13 1141.76 20 14.70 1967 578 2.99 / 734.32 2 6
5 13 541.12 20 14.84 1144 340 3.32 / 734.66 2 7
6 13 52.32 20 15.00 379 114 3.44 / 734.77 2 3
7 8 0.00 165 14.97 309 763 4.20 / 735.54 2 2
Average= 4.09
(KJ/cycle)

Cycle 178 GMT 26/ 2/2024 9: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 33 14.97 476 235 0.24 / 727.48 2 3
2 3 960.76 -1 15.28 0 0 0.00 / 727.48 2 3
3 7 2007.00 30 14.68 3094 1363 1.60 / 728.84 2 3
4 13 1607.84 20 14.65 2586 758 2.36 / 729.60 2 5
5 13 1032.20 20 14.73 1818 536 2.89 / 730.14 2 6
6 13 470.84 20 14.86 1040 309 3.20 / 730.44 2 7
7 13 72.68 20 14.99 407 122 3.32 / 730.57 2 3
8 8 0.16 165 14.97 311 768 4.09 / 731.33 2 3
Average= 4.09
(KJ/cycle)

Cycle 177 GMT 16/ 2/2024 13:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 32 14.95 451 216 0.22 / 723.27 2 3
2 3 1030.56 1 14.99 1901 28 0.24 / 723.29 2 5
3 7 2007.72 31 14.67 3094 1407 1.65 / 724.70 2 4
4 13 1597.96 20 14.66 2576 755 2.41 / 725.46 2 5
5 13 1027.60 20 14.73 1814 534 2.94 / 725.99 2 6
6 13 570.88 20 14.83 1186 352 3.29 / 726.34 2 7
7 8 1.56 165 14.98 309 764 4.06 / 727.11 2 2
8 14 1.56 30 14.96 308 138 4.19 / 727.24 2 3
Average= 4.09
(KJ/cycle)

Cycle 176 GMT 6/ 2/2024 18:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 32 14.94 468 224 0.22 / 719.12 2 3
2 3 1029.80 1 14.98 1897 28 0.25 / 719.15 2 5
3 7 2007.24 30 14.68 3085 1359 1.61 / 720.51 2 5
4 13 1608.08 20 14.65 2592 759 2.37 / 721.27 2 6
5 13 1039.80 20 14.72 1839 541 2.91 / 721.81 2 6
6 13 591.76 20 14.82 1216 360 3.27 / 722.17 2 7
7 13 60.80 20 15.00 388 116 3.39 / 722.29 2 3
8 8 0.36 165 14.98 309 764 4.15 / 723.05 2 3
Average= 4.09
(KJ/cycle)

Cycle 175 GMT 27/ 1/2024 22:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.68 33 14.95 490 242 0.24 / 714.88 2 3
2 3 956.44 -1 15.32 0 0 0.00 / 714.88 2 3
3 7 2004.04 30 14.67 3084 1357 1.60 / 716.24 2 4
4 13 1594.80 20 14.66 2572 754 2.35 / 716.99 2 6
5 13 1026.96 20 14.73 1815 535 2.89 / 717.53 2 6
6 13 578.80 20 14.83 1194 354 3.24 / 717.88 2 7
7 13 60.04 20 15.00 391 117 3.36 / 718.00 2 3
8 8 -0.08 165 14.98 307 759 4.12 / 718.76 2 2
9 14 -0.08 30 14.96 307 138 4.26 / 718.90 2 3
Average= 4.08
(KJ/cycle)

Cycle 174 GMT 18/ 1/2024 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 31 14.95 456 211 0.21 / 710.60 2 2
2 10 1002.24 3 14.94 1817 81 0.29 / 710.68 2 5
3 3 975.48 -1 15.32 0 0 0.08 / 710.68 2 5
4 7 2006.32 31 14.67 3079 1400 1.69 / 712.08 2 4
5 13 1725.72 20 14.64 2734 801 2.49 / 712.88 2 6
6 13 988.00 20 14.74 1766 521 3.01 / 713.40 2 7
7 13 551.80 20 14.84 1154 343 3.36 / 713.75 2 8
8 13 107.44 20 14.98 462 138 3.50 / 713.88 2 4
9 8 -0.16 165 14.98 306 756 4.25 / 714.64 2 3
Average= 4.08
(KJ/cycle)

Cycle 173 GMT 8/ 1/2024 3: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.04 32 14.95 502 240 0.24 / 706.50 2 3
2 3 976.84 -1 15.32 0 0 0.00 / 706.50 2 3
3 7 2004.88 30 14.68 3078 1356 1.60 / 707.85 2 4
4 13 1592.40 20 14.66 2563 751 2.35 / 708.61 2 5
5 13 1144.92 20 14.70 1976 581 2.93 / 709.19 2 6
6 13 534.48 20 14.84 1136 337 3.27 / 709.52 2 7
7 13 53.16 20 15.00 376 113 3.38 / 709.64 2 3
8 8 0.04 165 14.98 305 754 4.13 / 710.39 2 3
Average= 4.08
(KJ/cycle)

Cycle 172 GMT 29/12/2023 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 32 14.95 474 227 0.23 / 702.34 2 3
2 7 2006.68 30 14.69 3086 1360 1.59 / 703.70 2 4
3 13 1603.04 20 14.66 2577 756 2.34 / 704.46 2 5
4 13 1034.20 20 14.74 1826 538 2.88 / 705.00 2 6
5 13 583.56 20 14.83 1203 357 3.24 / 705.35 2 7
6 13 124.00 20 14.98 491 147 3.38 / 705.50 2 5
7 8 -0.04 165 14.98 307 759 4.14 / 706.26 2 2
Average= 4.08
(KJ/cycle)

Cycle 171 GMT 19/12/2023 7:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 32 14.96 458 219 0.22 / 698.26 2 3
2 7 2010.20 30 14.67 3078 1355 1.57 / 699.61 2 5
3 13 1594.48 20 14.66 2574 755 2.33 / 700.37 2 6
4 13 1006.12 20 14.74 1787 527 2.86 / 700.90 2 7
5 13 557.92 20 14.84 1170 347 3.20 / 701.24 2 7
6 13 63.44 20 15.00 391 117 3.32 / 701.36 2 3
7 8 0.12 165 14.99 305 754 4.07 / 702.11 2 3
Average= 4.08
(KJ/cycle)

Cycle 170 GMT 9/12/2023 9:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 31 14.96 459 213 0.21 / 694.01 2 3
2 3 1051.80 2 15.02 1945 58 0.27 / 694.07 2 4
3 7 2003.40 30 14.68 3080 1356 1.63 / 695.43 2 4
4 13 1601.96 20 14.66 2581 757 2.38 / 696.19 2 7
5 13 1024.60 20 14.73 1812 534 2.92 / 696.72 2 6
6 13 464.00 20 14.87 1028 306 3.22 / 697.02 2 7
7 13 75.16 20 15.00 404 121 3.35 / 697.15 2 3
8 8 0.00 165 14.98 306 756 4.10 / 697.90 2 2
9 14 0.00 30 14.96 307 138 4.24 / 698.04 2 4
Average= 4.08
(KJ/cycle)

Cycle 169 GMT 29/11/2023 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.00 31 14.96 489 227 0.23 / 689.93 2 3
2 3 969.28 -1 15.33 0 0 0.00 / 689.93 2 3
3 7 2007.68 30 14.68 3090 1361 1.59 / 691.29 2 4
4 13 1595.96 20 14.66 2572 754 2.34 / 692.05 2 6
5 13 1012.48 20 14.74 1800 531 2.87 / 692.58 2 6
6 13 564.00 20 14.84 1179 350 3.22 / 692.93 2 7
7 13 62.08 20 15.00 389 117 3.34 / 693.04 2 3
8 8 0.24 165 14.98 306 756 4.10 / 693.80 2 3
Average= 4.08
(KJ/cycle)

Cycle 168 GMT 19/11/2023 14:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 31 14.95 464 215 0.22 / 685.88 2 2
2 7 2010.52 30 14.68 3092 1362 1.58 / 687.24 2 4
3 13 1594.68 20 14.67 2565 753 2.33 / 687.99 2 6
4 13 1026.56 20 14.74 1812 534 2.86 / 688.52 2 7
5 13 453.80 20 14.88 1013 301 3.16 / 688.83 2 7
6 13 76.88 20 15.00 404 121 3.29 / 688.95 2 3
7 8 -0.12 165 14.98 307 759 4.04 / 689.71 2 3
Average= 4.08
(KJ/cycle)

Cycle 167 GMT 9/11/2023 16:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 32 14.96 460 220 0.22 / 681.82 2 3
2 7 2005.96 30 14.68 3091 1361 1.58 / 683.18 2 4
3 13 1599.00 20 14.66 2574 755 2.34 / 683.94 2 6
4 13 1021.36 20 14.74 1811 534 2.87 / 684.47 2 7
5 13 453.76 20 14.88 1016 302 3.17 / 684.77 2 7
6 13 68.04 20 15.00 399 120 3.29 / 684.89 2 3
7 8 0.00 165 14.98 310 766 4.06 / 685.66 2 3
Average= 4.08
(KJ/cycle)

Cycle 166 GMT 30/10/2023 18:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 31 14.96 461 214 0.21 / 677.54 2 3
2 3 1017.28 1 15.05 1888 28 0.24 / 677.57 2 5
3 7 2011.16 30 14.68 3094 1363 1.60 / 678.93 2 4
4 13 1609.20 20 14.67 2586 759 2.36 / 679.69 2 5
5 13 1041.80 20 14.74 1837 542 2.91 / 680.23 2 6
6 13 587.44 20 14.84 1211 359 3.26 / 680.59 2 7
7 13 67.92 20 15.00 395 118 3.38 / 680.71 2 3
8 8 -0.04 165 14.99 305 754 4.14 / 681.47 2 3
9 14 -0.04 30 14.97 304 137 4.27 / 681.60 2 3
Average= 4.08
(KJ/cycle)

Cycle 165 GMT 20/10/2023 20:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 31 14.96 453 210 0.21 / 673.45 2 3
2 3 1024.12 1 15.04 1913 29 0.24 / 673.48 2 5
3 7 2004.76 30 14.69 3085 1360 1.60 / 674.84 2 3
4 13 1605.08 20 14.67 2580 757 2.36 / 675.60 2 6
5 13 1041.08 20 14.74 1833 540 2.90 / 676.14 2 6
6 13 468.60 20 14.88 1036 308 3.20 / 676.45 2 7
7 13 77.12 20 15.00 410 123 3.33 / 676.57 2 3
8 8 0.12 165 14.99 306 757 4.08 / 677.33 2 5
Average= 4.08
(KJ/cycle)

Cycle 164 GMT 10/10/2023 23: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 31 14.96 466 216 0.22 / 669.30 2 2
2 7 2009.84 30 14.68 3096 1363 1.58 / 670.66 2 6
3 13 1605.08 20 14.66 2585 758 2.34 / 671.42 2 5
4 13 1031.04 20 14.73 1829 539 2.88 / 671.96 2 6
5 13 455.80 20 14.88 1022 304 3.18 / 672.26 2 7
6 13 71.88 20 15.00 402 121 3.30 / 672.38 2 3
7 13 15.88 20 15.01 327 98 3.40 / 672.48 2 2
8 8 -0.08 165 14.98 308 761 4.16 / 673.24 2 4
Average= 4.08
(KJ/cycle)

Cycle 163 GMT 1/10/2023 1: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 31 14.97 463 215 0.21 / 665.12 2 3
2 7 2011.48 30 14.69 3099 1366 1.58 / 666.48 2 4
3 13 1619.80 20 14.66 2605 764 2.34 / 667.25 2 6
4 13 1045.20 20 14.74 1842 543 2.89 / 667.79 2 6
5 13 468.92 20 14.88 1041 310 3.20 / 668.10 2 8
6 13 84.44 20 15.00 418 125 3.32 / 668.23 2 3
7 13 21.40 20 15.01 329 99 3.42 / 668.32 2 2
8 8 0.04 165 14.99 307 759 4.18 / 669.08 2 4
Average= 4.08
(KJ/cycle)

Cycle 162 GMT 21/ 9/2023 3: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 31 14.96 459 213 0.21 / 660.96 2 2
2 7 2003.60 30 14.70 3080 1358 1.57 / 662.32 2 4
3 13 1617.56 20 14.67 2606 765 2.34 / 663.08 2 6
4 13 1042.52 20 14.74 1841 543 2.88 / 663.62 2 6
5 13 473.32 20 14.88 1048 312 3.19 / 663.94 2 7
6 13 47.04 20 15.01 375 113 3.30 / 664.05 2 3
7 13 15.32 20 15.02 324 97 3.40 / 664.15 2 2
8 8 0.08 165 14.99 306 757 4.16 / 664.90 2 3
Average= 4.08
(KJ/cycle)

Cycle 161 GMT 11/ 9/2023 5:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 31 14.97 466 216 0.22 / 656.79 2 3
2 7 2011.04 30 14.68 3102 1366 1.58 / 658.16 2 4
3 13 1613.44 20 14.67 2594 761 2.34 / 658.92 2 5
4 13 1029.04 20 14.74 1826 538 2.88 / 659.46 2 7
5 13 451.24 20 14.88 1016 302 3.18 / 659.76 2 7
6 13 69.88 20 15.01 405 122 3.31 / 659.88 2 3
7 13 19.00 20 15.01 332 100 3.41 / 659.98 2 2
8 8 0.00 165 14.99 309 764 4.17 / 660.75 2 4
Average= 4.08
(KJ/cycle)

Cycle 160 GMT 1/ 9/2023 7:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 31 14.96 463 215 0.21 / 652.60 2 3
2 7 2006.00 30 14.69 3090 1362 1.58 / 653.96 2 5
3 13 1733.20 20 14.65 2743 804 2.38 / 654.77 2 6
4 13 998.24 20 14.76 1783 526 2.91 / 655.29 2 7
5 13 458.96 20 14.89 1026 306 3.21 / 655.60 2 8
6 13 85.08 20 15.01 419 126 3.34 / 655.72 2 3
7 13 18.60 20 15.02 330 99 3.44 / 655.82 2 2
8 8 0.16 165 14.99 305 754 4.19 / 656.58 2 3
Average= 4.08
(KJ/cycle)

Cycle 159 GMT 22/ 8/2023 9:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 31 14.97 452 210 0.21 / 648.35 2 3
2 7 2006.40 30 14.69 3083 1359 1.57 / 649.71 2 4
3 13 1745.32 20 14.65 2754 807 2.38 / 650.52 2 4
4 13 1118.84 20 14.73 1940 572 2.95 / 651.09 2 6
5 13 505.40 20 14.87 1093 325 3.27 / 651.41 2 8
6 13 52.80 20 15.02 382 115 3.39 / 651.53 2 3
7 13 14.40 20 15.02 325 98 3.48 / 651.63 2 2
8 8 0.04 165 14.99 307 759 4.24 / 652.39 2 3
Average= 4.08
(KJ/cycle)

Cycle 158 GMT 12/ 8/2023 11:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 31 14.96 463 215 0.21 / 644.22 2 3
2 7 2002.72 30 14.70 3092 1364 1.58 / 645.58 2 4
3 13 1596.76 20 14.68 2581 758 2.34 / 646.34 2 5
4 13 921.60 20 14.78 1683 497 2.83 / 646.83 2 7
5 13 486.20 20 14.88 1065 317 3.15 / 647.15 2 7
6 13 83.32 20 15.00 425 127 3.28 / 647.28 2 3
7 13 20.76 20 15.02 336 101 3.38 / 647.38 2 2
8 8 0.00 165 14.99 308 762 4.14 / 648.14 2 3
Average= 4.08
(KJ/cycle)

Cycle 157 GMT 2/ 8/2023 14: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 31 14.96 454 211 0.21 / 640.03 2 3
2 7 2003.08 30 14.70 3091 1363 1.57 / 641.39 2 5
3 13 1614.60 20 14.67 2602 763 2.34 / 642.15 2 6
4 13 1048.04 20 14.75 1858 548 2.89 / 642.70 2 7
5 13 473.20 20 14.88 1045 311 3.20 / 643.01 2 8
6 13 79.80 20 15.01 418 125 3.32 / 643.14 2 3
7 13 17.56 20 15.02 332 100 3.42 / 643.24 2 2
8 8 0.12 165 14.99 309 764 4.19 / 644.00 2 3
Average= 4.08
(KJ/cycle)

Cycle 156 GMT 23/ 7/2023 16:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 32 14.97 461 221 0.22 / 635.85 2 3
2 3 983.04 -1 15.34 0 0 0.00 / 635.85 2 3
3 7 2009.08 30 14.69 3096 1364 1.59 / 637.22 2 5
4 13 1621.92 20 14.67 2605 764 2.35 / 637.98 2 5
5 13 1035.32 20 14.75 1831 540 2.89 / 638.52 2 6
6 13 452.52 20 14.89 1017 303 3.19 / 638.83 2 6
7 13 69.92 20 15.01 405 122 3.31 / 638.95 2 3
8 13 16.40 20 15.02 329 99 3.41 / 639.05 2 2
9 8 0.04 165 14.99 311 769 4.18 / 639.81 2 3
Average= 4.08
(KJ/cycle)

Cycle 155 GMT 13/ 7/2023 18:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 32 14.97 465 223 0.22 / 631.79 2 3
2 3 975.64 -1 15.34 0 0 0.00 / 631.79 2 3
3 7 2009.08 30 14.69 3076 1356 1.58 / 633.15 2 4
4 13 1609.00 20 14.68 2588 760 2.34 / 633.91 2 5
5 13 1018.92 20 14.76 1812 535 2.87 / 634.44 2 6
6 13 450.56 20 14.89 1010 301 3.17 / 634.74 2 7
7 13 77.12 20 15.01 412 124 3.30 / 634.87 2 3
8 8 0.08 165 15.00 309 765 4.06 / 635.63 2 3
Average= 4.07
(KJ/cycle)

Cycle 154 GMT 3/ 7/2023 20:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 33 14.97 457 226 0.23 / 627.71 2 3
2 7 2008.08 30 14.70 3085 1360 1.59 / 629.07 2 4
3 13 1605.36 20 14.69 2593 762 2.35 / 629.83 2 5
4 13 1039.36 20 14.75 1840 543 2.89 / 630.37 2 7
5 13 469.32 20 14.89 1040 310 3.20 / 630.68 2 7
6 13 75.28 20 15.01 408 122 3.32 / 630.80 2 3
7 8 0.08 165 15.00 310 767 4.09 / 631.57 2 5
Average= 4.07
(KJ/cycle)

Cycle 153 GMT 23/ 6/2023 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 33 14.97 467 231 0.23 / 623.60 2 3
2 7 2008.88 31 14.70 3090 1408 1.64 / 625.01 2 4
3 13 1604.68 20 14.67 2582 758 2.40 / 625.77 2 4
4 13 1021.48 20 14.76 1812 535 2.93 / 626.30 2 7
5 13 441.92 20 14.90 996 297 3.23 / 626.60 2 7
6 13 63.76 20 15.02 397 119 3.35 / 626.72 2 3
7 8 -0.04 165 15.00 307 760 4.11 / 627.48 2 3
Average= 4.07
(KJ/cycle)

Cycle 152 GMT 14/ 6/2023 0:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 33 14.97 458 226 0.23 / 619.50 2 3
2 7 2010.44 30 14.69 3100 1366 1.59 / 620.86 2 5
3 13 1738.56 20 14.66 2741 804 2.40 / 621.67 2 6
4 13 995.52 20 14.77 1775 524 2.92 / 622.19 2 6
5 13 438.28 20 14.90 998 297 3.22 / 622.49 2 7
6 13 65.08 20 15.02 395 119 3.34 / 622.61 2 3
7 8 0.08 165 15.00 310 767 4.10 / 623.37 2 3
Average= 4.07
(KJ/cycle)

Cycle 151 GMT 4/ 6/2023 3:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 33 14.97 463 229 0.23 / 615.43 2 2
2 7 2009.64 30 14.69 3096 1364 1.59 / 616.80 2 4
3 13 1601.92 20 14.69 2576 757 2.35 / 617.55 2 5
4 13 1005.36 20 14.77 1796 531 2.88 / 618.08 2 7
5 13 446.20 20 14.90 1010 301 3.18 / 618.39 2 6
6 13 64.28 20 15.02 395 119 3.30 / 618.50 2 3
7 8 0.00 165 15.00 309 765 4.06 / 619.27 2 3
Average= 4.07
(KJ/cycle)

Cycle 150 GMT 25/ 5/2023 5:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 33 14.97 459 227 0.23 / 611.32 2 3
2 3 1020.40 1 15.05 1901 29 0.26 / 611.35 2 5
3 7 2008.08 30 14.70 3092 1364 1.62 / 612.72 2 4
4 13 1606.20 20 14.68 2589 760 2.38 / 613.48 2 5
5 13 1024.16 20 14.76 1820 537 2.92 / 614.01 2 6
6 13 444.08 20 14.90 1004 299 3.22 / 614.31 2 8
7 13 65.28 20 15.02 398 120 3.34 / 614.43 2 3
8 8 0.16 165 15.00 312 772 4.11 / 615.20 2 3
Average= 4.07
(KJ/cycle)

Cycle 149 GMT 15/ 5/2023 7:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 33 14.97 450 222 0.22 / 607.23 2 3
2 7 2009.52 30 14.71 3096 1366 1.59 / 608.59 2 4
3 13 1616.24 20 14.68 2599 763 2.35 / 609.36 2 6
4 13 1041.56 20 14.76 1836 542 2.89 / 609.90 2 7
5 13 454.16 20 14.90 1019 304 3.20 / 610.20 2 8
6 13 78.48 20 15.02 415 125 3.32 / 610.33 2 3
7 8 -0.04 165 15.00 311 770 4.09 / 611.10 2 3
Average= 4.07
(KJ/cycle)

Cycle 148 GMT 5/ 5/2023 9:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 33 14.97 459 227 0.23 / 603.11 2 2
2 7 2004.28 31 14.70 3087 1407 1.63 / 604.52 2 4
3 13 1613.56 20 14.68 2600 763 2.40 / 605.28 2 5
4 13 1037.00 20 14.76 1831 541 2.94 / 605.82 2 7
5 13 450.84 20 14.90 1010 301 3.24 / 606.12 2 8
6 13 70.80 20 15.02 407 122 3.36 / 606.24 2 3
7 8 0.20 165 15.01 308 763 4.12 / 607.01 2 3
Average= 4.07
(KJ/cycle)

Cycle 147 GMT 25/ 4/2023 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 33 14.97 454 224 0.22 / 598.97 2 3
2 3 1015.84 1 15.07 1888 28 0.25 / 599.00 2 4
3 7 2009.68 31 14.70 3097 1411 1.66 / 600.41 2 4
4 13 1597.28 20 14.69 2577 757 2.42 / 601.17 2 6
5 13 1011.52 20 14.77 1789 528 2.95 / 601.70 2 6
6 13 441.32 20 14.91 999 298 3.25 / 601.99 2 7
7 13 66.20 20 15.03 402 121 3.37 / 602.11 2 3
8 8 -0.12 165 15.01 310 768 4.14 / 602.88 2 3
Average= 4.07
(KJ/cycle)

Cycle 146 GMT 15/ 4/2023 14:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 33 14.98 456 225 0.23 / 594.78 2 3
2 7 2005.84 30 14.71 3074 1357 1.58 / 596.14 2 3
3 13 1612.72 20 14.69 2590 761 2.34 / 596.90 2 5
4 13 1164.72 20 14.73 2005 591 2.93 / 597.49 2 6
5 13 549.28 20 14.88 1158 345 3.28 / 597.83 2 7
6 13 111.80 20 15.01 471 141 3.42 / 597.97 2 4
7 8 0.04 165 15.01 312 773 4.19 / 598.75 2 3
Average= 4.07
(KJ/cycle)

Cycle 145 GMT 5/ 4/2023 16:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 31 14.98 456 212 0.21 / 590.52 2 3
2 10 1018.56 3 14.96 1838 82 0.29 / 590.61 2 5
3 3 980.28 -1 15.34 0 0 0.08 / 590.61 2 5
4 7 2007.88 30 14.71 3098 1367 1.66 / 591.97 2 4
5 13 1726.92 20 14.68 2754 809 2.47 / 592.78 2 5
6 13 1113.56 20 14.75 1936 571 3.04 / 593.35 2 6
7 13 527.24 20 14.88 1123 334 3.38 / 593.69 2 7
8 13 55.60 20 15.04 379 114 3.49 / 593.80 2 3
9 8 0.00 165 15.01 304 753 4.24 / 594.55 2 3
Average= 4.07
(KJ/cycle)

Cycle 144 GMT 26/ 3/2023 18:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.40 33 14.97 500 247 0.25 / 586.46 2 3
2 3 929.04 -2 15.35 0 0 0.00 / 586.46 2 3
3 3 979.92 -1 15.37 0 0 0.00 / 586.46 2 3
4 7 2009.12 30 14.70 3090 1363 1.61 / 587.82 2 4
5 13 1617.24 20 14.69 2589 761 2.37 / 588.59 2 6
6 13 1032.12 20 14.76 1822 538 2.91 / 589.12 2 6
7 13 452.80 20 14.91 1008 301 3.21 / 589.42 2 7
8 13 73.04 20 15.03 406 122 3.33 / 589.55 2 3
9 8 0.12 165 15.01 309 765 4.10 / 590.31 2 4
Average= 4.07
(KJ/cycle)

Cycle 143 GMT 16/ 3/2023 20:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 33 14.98 453 224 0.22 / 582.26 2 3
2 7 2005.84 30 14.71 3080 1359 1.58 / 583.61 2 3
3 13 1752.92 20 14.67 2776 814 2.40 / 584.43 2 5
4 13 1119.44 20 14.75 1941 573 2.97 / 585.00 2 6
5 13 523.84 20 14.89 1115 332 3.30 / 585.33 2 7
6 13 51.60 20 15.04 384 116 3.42 / 585.45 2 3
7 8 -0.08 165 15.02 309 766 4.18 / 586.22 2 2
Average= 4.07
(KJ/cycle)

Cycle 142 GMT 6/ 3/2023 23: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 33 14.98 463 229 0.23 / 578.12 2 2
2 7 2009.20 30 14.72 3097 1368 1.60 / 579.49 2 5
3 13 1608.96 20 14.69 2587 760 2.36 / 580.25 2 5
4 13 1033.08 20 14.77 1826 539 2.90 / 580.79 2 7
5 13 587.76 20 14.87 1211 360 3.26 / 581.15 2 8
6 13 64.52 20 15.03 400 120 3.38 / 581.27 2 3
7 8 -0.08 165 15.01 309 765 4.14 / 582.03 2 2
Average= 4.07
(KJ/cycle)

Cycle 141 GMT 25/ 2/2023 1:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 33 14.97 462 228 0.23 / 574.01 2 3
2 10 1005.08 2 14.98 1842 55 0.28 / 574.06 2 4
3 3 970.08 -1 15.34 0 0 0.06 / 574.06 2 4
4 7 2009.72 30 14.70 3095 1365 1.65 / 575.43 2 5
5 13 1591.44 20 14.70 2572 756 2.40 / 576.18 2 5
6 13 1009.48 20 14.77 1799 531 2.94 / 576.71 2 6
7 13 439.96 20 14.92 999 298 3.23 / 577.01 2 7
8 13 60.36 20 15.03 389 117 3.35 / 577.13 2 3
9 8 0.00 165 15.01 307 760 4.11 / 577.89 2 4
Average= 4.07
(KJ/cycle)

Cycle 140 GMT 15/ 2/2023 3:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 31 14.98 466 216 0.22 / 569.86 2 3
2 10 1020.52 3 14.95 1852 83 0.30 / 569.95 2 4
3 7 2006.68 30 14.71 3082 1360 1.66 / 571.31 2 4
4 13 1575.84 20 14.70 2547 749 2.41 / 572.06 2 5
5 13 979.24 20 14.79 1757 520 2.93 / 572.58 2 7
6 13 524.48 20 14.89 1114 332 3.26 / 572.91 2 8
7 13 45.48 20 15.04 367 110 3.37 / 573.02 2 3
8 8 -0.04 165 15.01 307 760 4.13 / 573.78 2 3
Average= 4.07
(KJ/cycle)

Cycle 139 GMT 5/ 2/2023 5:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 31 14.98 485 225 0.23 / 565.70 2 3
2 7 2003.12 30 14.72 3088 1364 1.59 / 567.06 2 4
3 13 1727.12 20 14.68 2741 805 2.39 / 567.87 2 5
4 13 1120.00 20 14.75 1943 573 2.97 / 568.44 2 6
5 13 517.48 20 14.90 1107 330 3.30 / 568.77 2 7
6 13 48.00 20 15.04 378 114 3.41 / 568.88 2 3
7 8 0.24 165 15.02 308 763 4.17 / 569.65 2 3
Average= 4.07
(KJ/cycle)

Cycle 138 GMT 26/ 1/2023 7:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.88 31 14.98 506 235 0.23 / 561.47 2 3
2 7 2008.04 30 14.71 3078 1358 1.59 / 562.83 2 4
3 13 1594.64 20 14.69 2572 756 2.35 / 563.58 2 6
4 13 1003.64 20 14.78 1785 528 2.88 / 564.11 2 6
5 13 558.28 20 14.88 1164 346 3.22 / 564.46 2 7
6 13 57.16 20 15.04 385 116 3.34 / 564.57 2 3
7 8 0.08 165 15.02 307 761 4.10 / 565.34 2 3
8 14 0.08 30 15.00 309 139 4.24 / 565.47 2 3
Average= 4.07
(KJ/cycle)

Cycle 137 GMT 16/ 1/2023 10: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 32 14.99 485 233 0.23 / 557.44 2 3
2 3 945.12 -2 15.36 0 0 0.00 / 557.44 2 3
3 7 2003.36 30 14.71 3078 1358 1.59 / 558.79 2 5
4 13 1579.44 20 14.70 2545 748 2.34 / 559.54 2 6
5 13 991.40 20 14.79 1768 523 2.86 / 560.07 2 7
6 13 428.20 20 14.93 976 291 3.15 / 560.36 2 6
7 13 62.00 20 15.04 393 118 3.27 / 560.47 2 3
8 8 0.32 165 15.02 307 761 4.03 / 561.24 2 2
Average= 4.07
(KJ/cycle)

Cycle 136 GMT 6/ 1/2023 12: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 32 14.99 454 218 0.22 / 553.06 2 3
2 3 1023.40 1 15.06 1906 29 0.25 / 553.09 2 5
3 7 2009.24 30 14.72 3096 1367 1.61 / 554.45 2 4
4 13 1745.60 20 14.68 2765 812 2.43 / 555.27 2 6
5 13 1121.72 20 14.76 1947 575 3.00 / 555.84 2 7
6 13 516.52 20 14.90 1110 331 3.33 / 556.17 2 8
7 13 101.24 20 15.03 442 133 3.46 / 556.30 2 3
8 8 0.08 165 15.02 307 761 4.22 / 557.06 2 3
9 14 0.08 30 15.00 307 138 4.36 / 557.20 2 3
Average= 4.07
(KJ/cycle)

Cycle 135 GMT 27/12/2022 14:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 32 15.00 446 214 0.21 / 548.94 2 3
2 7 2009.92 30 14.72 3090 1365 1.58 / 550.31 2 4
3 13 1734.36 20 14.68 2753 808 2.39 / 551.12 2 5
4 13 1007.48 20 14.79 1796 531 2.92 / 551.65 2 6
5 13 456.68 20 14.92 1022 305 3.22 / 551.95 2 7
6 13 81.00 20 15.04 419 126 3.35 / 552.08 2 3
7 8 0.08 165 15.03 307 761 4.11 / 552.84 2 3
Average= 4.07
(KJ/cycle)

Cycle 134 GMT 17/12/2022 16:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 30 14.99 466 210 0.21 / 544.70 2 3
2 10 1003.88 2 14.98 1826 55 0.26 / 544.76 2 4
3 7 2012.24 30 14.71 3098 1367 1.63 / 546.12 2 3
4 13 1605.48 20 14.70 2584 760 2.39 / 546.88 2 5
5 13 1011.68 20 14.78 1796 531 2.92 / 547.42 2 6
6 13 434.12 20 14.93 987 295 3.22 / 547.71 2 6
7 13 62.64 20 15.04 390 117 3.33 / 547.83 2 3
8 8 -0.08 165 15.02 308 763 4.10 / 548.59 2 4
9 14 -0.08 30 15.00 309 139 4.24 / 548.73 2 3
Average= 4.06
(KJ/cycle)

Cycle 133 GMT 7/12/2022 18:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 32 14.99 477 229 0.23 / 540.62 2 3
2 3 941.28 -2 15.36 0 0 0.00 / 540.62 2 3
3 7 2003.64 30 14.73 3086 1364 1.59 / 541.99 2 5
4 13 1724.96 20 14.69 2729 802 2.39 / 542.79 2 5
5 13 986.68 20 14.80 1768 523 2.92 / 543.31 2 6
6 13 434.20 20 14.93 987 295 3.21 / 543.61 2 7
7 13 70.56 20 15.04 407 122 3.33 / 543.73 2 3
8 8 0.00 165 15.03 308 764 4.10 / 544.49 2 2
Average= 4.06
(KJ/cycle)

Cycle 132 GMT 27/11/2022 20:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 31 14.99 458 213 0.21 / 536.34 2 3
2 3 1034.52 1 15.06 1927 29 0.24 / 536.36 2 4
3 7 2007.96 30 14.71 3093 1365 1.61 / 537.73 2 4
4 13 1607.76 20 14.70 2574 757 2.36 / 538.49 2 5
5 13 1015.84 20 14.79 1810 535 2.90 / 539.02 2 7
6 13 561.56 20 14.89 1173 349 3.25 / 539.37 2 8
7 13 56.96 20 15.04 395 119 3.37 / 539.49 2 3
8 8 0.08 165 15.03 309 766 4.13 / 540.26 2 2
9 14 0.08 30 15.01 309 139 4.27 / 540.39 2 2
Average= 4.06
(KJ/cycle)

Cycle 131 GMT 17/11/2022 22:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 31 15.00 460 214 0.21 / 532.26 2 3
2 7 2002.80 30 14.71 3081 1360 1.57 / 533.62 2 4
3 13 1596.84 20 14.71 2579 759 2.33 / 534.38 2 6
4 13 1035.88 20 14.78 1831 541 2.87 / 534.92 2 7
5 13 460.16 20 14.92 1027 306 3.18 / 535.23 2 7
6 13 72.20 20 15.04 409 123 3.30 / 535.35 2 3
7 8 -0.08 165 15.02 311 771 4.07 / 536.12 2 4
Average= 4.06
(KJ/cycle)

Cycle 130 GMT 8/11/2022 0:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 31 14.99 474 220 0.22 / 528.23 2 2
2 7 2004.56 30 14.71 3095 1366 1.59 / 529.60 2 4
3 13 1581.36 20 14.71 2557 752 2.34 / 530.35 2 5
4 13 995.04 20 14.79 1777 526 2.86 / 530.88 2 7
5 13 419.84 20 14.94 962 287 3.15 / 531.16 2 7
6 13 57.56 20 15.05 394 119 3.27 / 531.28 2 3
7 8 0.08 165 15.03 309 766 4.04 / 532.05 2 3
Average= 4.06
(KJ/cycle)

Cycle 129 GMT 29/10/2022 2:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 31 14.99 459 213 0.21 / 523.99 2 3
2 7 2002.48 30 14.73 3087 1364 1.58 / 525.35 2 4
3 13 1605.52 20 14.71 2586 761 2.34 / 526.11 2 5
4 13 1025.92 20 14.79 1825 540 2.88 / 526.65 2 6
5 13 565.56 20 14.88 1188 354 3.23 / 527.01 2 7
6 13 54.52 20 15.05 392 118 3.35 / 527.13 2 3
7 13 30.76 20 15.05 344 104 3.45 / 527.23 2 2
8 8 0.12 165 15.02 316 783 4.24 / 528.01 2 3
Average= 4.06
(KJ/cycle)

Cycle 128 GMT 19/10/2022 5: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 31 15.01 448 208 0.21 / 519.69 2 3
2 7 2008.96 30 14.73 3091 1366 1.57 / 521.05 2 5
3 13 1601.40 20 14.71 2578 758 2.33 / 521.81 2 5
4 13 1025.24 20 14.79 1823 539 2.87 / 522.35 2 6
5 13 450.60 20 14.93 1013 302 3.17 / 522.65 2 8
6 13 72.52 20 15.05 400 120 3.29 / 522.77 2 3
7 13 16.88 20 15.06 329 99 3.39 / 522.87 2 2
8 8 -0.04 165 15.02 308 763 4.16 / 523.64 2 3
9 14 -0.04 30 15.00 308 139 4.30 / 523.78 2 3
Average= 4.06
(KJ/cycle)

Cycle 127 GMT 9/10/2022 7: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 31 15.00 466 217 0.22 / 515.41 2 2
2 7 2004.04 30 14.72 3088 1364 1.58 / 516.78 2 4
3 13 1576.28 20 14.72 2542 748 2.33 / 517.53 2 6
4 13 999.68 20 14.80 1779 527 2.86 / 518.05 2 6
5 13 433.12 20 14.94 983 294 3.15 / 518.35 2 6
6 13 62.80 20 15.05 388 117 3.27 / 518.46 2 3
7 13 34.72 20 15.05 359 108 3.37 / 518.57 2 3
8 8 -0.16 165 15.02 310 768 4.14 / 519.34 2 6
9 14 -0.16 30 15.00 313 141 4.28 / 519.48 2 3
Average= 4.06
(KJ/cycle)

Cycle 126 GMT 29/ 9/2022 9:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 31 15.00 453 211 0.21 / 511.23 2 3
2 7 2007.64 30 14.72 3087 1363 1.57 / 512.59 2 6
3 13 1732.00 20 14.69 2759 811 2.38 / 513.40 2 5
4 13 984.96 20 14.81 1767 523 2.91 / 513.92 2 6
5 13 418.68 20 14.94 960 287 3.19 / 514.21 2 7
6 13 58.76 20 15.05 393 118 3.31 / 514.33 2 3
7 13 33.16 20 15.06 344 104 3.42 / 514.43 2 2
8 8 0.04 165 15.03 308 764 4.18 / 515.20 2 4
Average= 4.06
(KJ/cycle)

Cycle 125 GMT 19/ 9/2022 11:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 30 15.01 462 208 0.21 / 507.05 2 2
2 7 2006.88 30 14.73 3086 1364 1.57 / 508.41 2 4
3 13 1608.80 20 14.71 2587 761 2.33 / 509.17 2 6
4 13 1043.32 20 14.79 1842 545 2.88 / 509.72 2 7
5 13 468.88 20 14.93 1040 311 3.19 / 510.03 2 7
6 13 71.92 20 15.05 411 124 3.31 / 510.15 2 3
7 13 18.48 20 15.06 333 100 3.41 / 510.25 2 2
8 8 0.08 165 15.03 308 764 4.18 / 511.02 2 3
Average= 4.06
(KJ/cycle)

Cycle 124 GMT 9/ 9/2022 13:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 30 15.01 454 204 0.20 / 502.71 2 3
2 10 1008.32 2 15.01 1844 55 0.26 / 502.77 2 4
3 3 962.68 -1 15.37 0 0 0.06 / 502.77 2 4
4 7 2004.16 30 14.73 3091 1366 1.63 / 504.14 2 4
5 13 1729.12 20 14.69 2744 806 2.43 / 504.94 2 5
6 13 1120.48 20 14.77 1945 575 3.01 / 505.52 2 6
7 13 528.68 20 14.91 1133 338 3.34 / 505.85 2 7
8 13 57.40 20 15.06 392 118 3.46 / 505.97 2 3
9 13 34.04 20 15.06 355 107 3.57 / 506.08 2 3
10 8 0.20 165 15.03 307 761 4.33 / 506.84 2 6
Average= 4.05
(KJ/cycle)

Cycle 123 GMT 30/ 8/2022 15:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 29 15.02 465 203 0.20 / 498.52 2 2
2 3 1029.36 1 15.08 1915 29 0.23 / 498.55 2 5
3 7 2001.88 31 14.72 3081 1406 1.64 / 499.96 2 4
4 13 1585.48 20 14.72 2557 753 2.39 / 500.71 2 5
5 13 1007.92 20 14.80 1798 532 2.92 / 501.24 2 6
6 13 431.48 20 14.94 979 293 3.21 / 501.54 2 6
7 13 58.96 20 15.06 385 116 3.33 / 501.65 2 3
8 13 15.44 20 15.07 325 98 3.43 / 501.75 2 2
9 8 -0.04 165 15.03 306 759 4.19 / 502.51 2 3
Average= 4.05
(KJ/cycle)

Cycle 122 GMT 20/ 8/2022 17:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 30 15.01 460 207 0.21 / 494.50 2 3
2 3 984.36 -1 15.40 0 0 0.00 / 494.50 2 3
3 7 2002.40 30 14.72 3085 1362 1.57 / 495.86 2 4
4 13 1594.52 20 14.72 2566 755 2.32 / 496.61 2 5
5 13 1024.84 20 14.80 1811 536 2.86 / 497.15 2 7
6 13 445.20 20 14.94 997 298 3.16 / 497.45 2 6
7 13 68.56 20 15.05 400 120 3.28 / 497.57 2 3
8 8 0.00 165 15.04 304 754 4.03 / 498.32 2 4
Average= 4.05
(KJ/cycle)

Cycle 121 GMT 10/ 8/2022 19:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 31 15.02 466 217 0.22 / 490.43 2 3
2 3 977.92 -1 15.37 0 0 0.00 / 490.43 2 3
3 7 2008.36 30 14.72 3097 1368 1.58 / 491.80 2 5
4 13 1612.08 20 14.71 2607 767 2.35 / 492.57 2 6
5 13 1030.52 20 14.79 1827 540 2.89 / 493.11 2 7
6 13 451.80 20 14.94 1014 303 3.20 / 493.41 2 8
7 13 67.52 20 15.06 397 120 3.31 / 493.53 2 3
8 8 0.04 165 15.04 306 759 4.07 / 494.29 2 4
Average= 4.05
(KJ/cycle)

Cycle 120 GMT 31/ 7/2022 21:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 31 15.02 464 216 0.22 / 486.28 2 3
2 7 2005.96 31 14.72 3090 1410 1.63 / 487.69 2 4
3 13 1607.00 20 14.72 2590 762 2.39 / 488.46 2 6
4 13 1020.44 20 14.80 1813 537 2.93 / 488.99 2 7
5 13 557.12 20 14.91 1169 349 3.27 / 489.34 2 7
6 13 56.76 20 15.06 385 116 3.39 / 489.46 2 3
7 8 0.12 165 15.05 305 757 4.15 / 490.21 2 3
Average= 4.05
(KJ/cycle)

Cycle 119 GMT 21/ 7/2022 23:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 30 15.02 455 205 0.21 / 482.24 2 3
2 7 2008.84 30 14.73 3090 1365 1.57 / 483.61 2 5
3 13 1595.96 20 14.72 2571 757 2.33 / 484.37 2 5
4 13 1009.80 20 14.81 1801 533 2.86 / 484.90 2 7
5 13 433.92 20 14.95 981 293 3.15 / 485.19 2 7
6 13 63.20 20 15.07 390 118 3.27 / 485.31 2 3
7 8 -0.04 165 15.05 305 757 4.03 / 486.07 2 3
Average= 4.05
(KJ/cycle)

Cycle 118 GMT 12/ 7/2022 2: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 31 15.01 467 217 0.22 / 478.19 2 3
2 3 976.28 -1 15.37 0 0 0.00 / 478.19 2 3
3 7 2005.12 30 14.75 3090 1367 1.58 / 479.56 2 4
4 13 1598.20 20 14.73 2573 758 2.34 / 480.31 2 5
5 13 1024.60 20 14.81 1823 540 2.88 / 480.85 2 7
6 13 459.76 20 14.94 1022 305 3.19 / 481.16 2 7
7 13 74.76 20 15.07 403 121 3.31 / 481.28 2 3
8 8 0.04 165 15.05 305 757 4.07 / 482.04 2 3
Average= 4.05
(KJ/cycle)

Cycle 117 GMT 2/ 7/2022 4: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 31 15.02 458 213 0.21 / 474.12 2 3
2 7 2004.40 30 14.74 3082 1363 1.58 / 475.48 2 5
3 13 1603.76 20 14.72 2577 759 2.33 / 476.24 2 7
4 13 1031.88 20 14.80 1823 540 2.87 / 476.78 2 7
5 13 455.76 20 14.95 1018 304 3.18 / 477.08 2 8
6 13 73.40 20 15.06 407 123 3.30 / 477.21 2 3
7 8 0.00 165 15.05 308 765 4.07 / 477.97 2 3
Average= 4.05
(KJ/cycle)

Cycle 116 GMT 22/ 6/2022 6:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 31 15.02 463 216 0.22 / 470.05 2 3
2 7 2009.80 30 14.72 3097 1368 1.58 / 471.42 2 4
3 13 1608.96 20 14.72 2592 763 2.35 / 472.18 2 6
4 13 1032.00 20 14.81 1825 541 2.89 / 472.72 2 6
5 13 439.52 20 14.95 993 297 3.18 / 473.02 2 7
6 13 61.08 20 15.07 393 118 3.30 / 473.14 2 3
7 8 0.08 165 15.05 308 765 4.07 / 473.91 2 4
Average= 4.05
(KJ/cycle)

Cycle 115 GMT 12/ 6/2022 8:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 31 15.02 452 210 0.21 / 466.01 2 3
2 7 2005.56 30 14.73 3083 1362 1.57 / 467.38 2 4
3 13 1595.08 20 14.73 2576 759 2.33 / 468.14 2 6
4 13 996.88 20 14.82 1780 528 2.86 / 468.66 2 6
5 13 417.84 20 14.96 959 287 3.15 / 468.95 2 7
6 13 59.60 20 15.07 393 118 3.26 / 469.07 2 3
7 8 0.24 165 15.05 310 770 4.03 / 469.84 2 5
Average= 4.05
(KJ/cycle)

Cycle 114 GMT 2/ 6/2022 10:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 31 15.02 463 216 0.22 / 461.92 2 3
2 7 2010.92 31 14.73 3099 1415 1.63 / 463.34 2 4
3 13 1605.20 20 14.72 2575 758 2.39 / 464.10 2 6
4 13 1000.12 20 14.82 1785 529 2.92 / 464.63 2 6
5 13 417.68 20 14.96 963 288 3.21 / 464.91 2 7
6 13 59.28 20 15.07 390 118 3.32 / 465.03 2 3
7 8 -0.08 165 15.05 311 772 4.10 / 465.80 2 4
Average= 4.05
(KJ/cycle)

Cycle 113 GMT 23/ 5/2022 12:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 31 15.03 458 213 0.21 / 457.86 2 3
2 7 2006.00 30 14.75 3096 1370 1.58 / 459.23 2 4
3 13 1601.36 20 14.73 2589 763 2.35 / 459.99 2 6
4 13 1007.40 20 14.82 1799 533 2.88 / 460.52 2 7
5 13 434.56 20 14.96 984 294 3.17 / 460.82 2 7
6 13 62.24 20 15.07 396 119 3.29 / 460.93 2 3
7 8 0.04 165 15.06 311 773 4.07 / 461.71 2 2
Average= 4.05
(KJ/cycle)

Cycle 112 GMT 13/ 5/2022 14:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 31 15.02 461 215 0.21 / 453.79 2 3
2 7 2005.52 30 14.74 3087 1365 1.58 / 455.15 2 4
3 13 1602.76 20 14.73 2585 762 2.34 / 455.91 2 5
4 13 1030.12 20 14.81 1827 541 2.88 / 456.45 2 6
5 13 447.32 20 14.96 1005 301 3.18 / 456.75 2 8
6 13 68.68 20 15.07 406 122 3.31 / 456.88 2 3
7 8 0.00 165 15.05 308 765 4.07 / 457.64 2 2
Average= 4.05
(KJ/cycle)

Cycle 111 GMT 3/ 5/2022 16:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 31 15.02 460 214 0.21 / 449.81 2 3
2 7 2009.60 30 14.73 3095 1368 1.58 / 451.18 2 4
3 13 1598.60 20 14.73 2572 758 2.34 / 451.94 2 5
4 13 892.52 20 14.85 1641 487 2.83 / 452.43 2 6
5 13 355.56 20 14.99 870 261 3.09 / 452.69 2 7
6 13 46.96 20 15.08 376 113 3.20 / 452.80 2 3
7 8 -0.04 165 15.05 310 770 3.97 / 453.57 2 4
Average= 4.05
(KJ/cycle)

Cycle 110 GMT 23/ 4/2022 18:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 31 15.03 459 214 0.21 / 445.77 2 2
2 7 2005.60 30 14.74 3088 1366 1.58 / 447.14 2 4
3 13 1590.68 20 14.73 2572 758 2.34 / 447.89 2 5
4 13 999.88 20 14.82 1781 528 2.86 / 448.42 2 5
5 13 430.72 20 14.96 986 295 3.16 / 448.72 2 7
6 13 60.20 20 15.08 392 118 3.28 / 448.84 2 3
7 8 0.08 165 15.06 308 765 4.04 / 449.60 2 3
Average= 4.05
(KJ/cycle)

Cycle 109 GMT 13/ 4/2022 20:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 31 15.03 462 215 0.22 / 441.73 2 3
2 7 2002.48 30 14.74 3077 1361 1.58 / 443.09 2 4
3 13 1591.24 20 14.74 2568 757 2.33 / 443.85 2 5
4 13 1006.64 20 14.83 1794 532 2.87 / 444.38 2 7
5 13 432.32 20 14.96 987 295 3.16 / 444.68 2 7
6 13 60.12 20 15.08 392 118 3.28 / 444.80 2 3
7 8 -0.04 165 15.06 306 760 4.04 / 445.56 2 2
Average= 4.05
(KJ/cycle)

Cycle 108 GMT 3/ 4/2022 23: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 31 15.03 463 216 0.22 / 437.69 2 3
2 7 2003.88 30 14.74 3085 1364 1.58 / 439.06 2 4
3 13 1586.24 20 14.74 2562 755 2.34 / 439.81 2 6
4 13 1001.84 20 14.83 1790 531 2.87 / 440.34 2 6
5 13 426.80 20 14.97 974 292 3.16 / 440.63 2 7
6 13 63.40 20 15.08 396 119 3.28 / 440.75 2 3
7 8 0.16 165 15.06 308 765 4.04 / 441.52 2 3
Average= 4.05
(KJ/cycle)

Cycle 107 GMT 25/ 3/2022 1:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 30 15.03 462 208 0.21 / 433.56 2 2
2 3 1044.60 1 15.07 1928 29 0.24 / 433.59 2 5
3 7 2004.16 30 14.75 3090 1367 1.60 / 434.96 2 4
4 13 1733.28 20 14.72 2747 809 2.41 / 435.77 2 6
5 13 1001.36 20 14.83 1787 530 2.94 / 436.30 2 6
6 13 438.12 20 14.97 990 296 3.24 / 436.59 2 8
7 13 73.40 20 15.08 403 122 3.36 / 436.71 2 3
8 8 0.00 165 15.07 306 761 4.12 / 437.48 2 3
Average= 4.05
(KJ/cycle)

Cycle 106 GMT 15/ 3/2022 3:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 31 15.03 477 222 0.22 / 429.51 2 3
2 3 978.72 -1 15.39 0 0 0.00 / 429.51 2 3
3 7 2008.56 30 14.74 3097 1369 1.59 / 430.88 2 4
4 13 1590.60 20 14.74 2572 758 2.35 / 431.64 2 6
5 13 1003.52 20 14.83 1788 530 2.88 / 432.17 2 6
6 13 431.32 20 14.97 984 295 3.17 / 432.46 2 8
7 13 61.28 20 15.08 395 119 3.29 / 432.58 2 3
8 8 0.08 165 15.06 310 770 4.06 / 433.35 2 3
Average= 4.05
(KJ/cycle)

Cycle 105 GMT 5/ 3/2022 5:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 31 15.02 470 219 0.22 / 425.30 2 3
2 3 982.64 -1 15.38 0 0 0.00 / 425.30 2 3
3 7 2004.44 30 14.75 3082 1364 1.58 / 426.66 2 4
4 13 1596.84 20 14.75 2572 759 2.34 / 427.42 2 5
5 13 1008.76 20 14.83 1801 534 2.88 / 427.95 2 7
6 13 438.48 20 14.97 998 299 3.17 / 428.25 2 7
7 13 70.84 20 15.08 406 122 3.30 / 428.38 2 3
8 8 0.16 165 15.06 311 773 4.07 / 429.15 2 2
9 14 0.16 30 15.04 311 140 4.21 / 429.29 2 3
Average= 4.05
(KJ/cycle)

Cycle 104 GMT 23/ 2/2022 7:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 30 15.03 462 208 0.21 / 421.10 2 3
2 3 1040.76 1 15.08 1917 29 0.24 / 421.13 2 5
3 7 2003.36 30 14.74 3084 1364 1.60 / 422.49 2 5
4 13 1594.40 20 14.75 2568 758 2.36 / 423.25 2 5
5 13 897.56 20 14.86 1652 491 2.85 / 423.74 2 6
6 13 471.92 20 14.96 1034 309 3.16 / 424.05 2 7
7 13 75.36 20 15.08 414 125 3.28 / 424.18 2 3
8 8 -0.08 165 15.06 307 763 4.05 / 424.94 2 3
9 14 -0.08 30 15.04 309 139 4.19 / 425.08 2 2
Average= 4.05
(KJ/cycle)

Cycle 103 GMT 13/ 2/2022 9:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 31 15.03 468 218 0.22 / 417.05 2 3
2 3 978.24 -1 15.39 0 0 0.00 / 417.05 2 3
3 7 2009.92 30 14.74 3098 1370 1.59 / 418.42 2 4
4 13 1603.40 20 14.74 2582 761 2.35 / 419.18 2 6
5 13 1023.52 20 14.83 1813 538 2.89 / 419.72 2 7
6 13 433.04 20 14.97 981 294 3.18 / 420.01 2 6
7 13 56.64 20 15.08 388 117 3.30 / 420.13 2 3
8 8 0.08 165 15.07 308 766 4.06 / 420.89 2 3
Average= 4.05
(KJ/cycle)

Cycle 102 GMT 3/ 2/2022 11:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 31 15.03 479 223 0.22 / 412.88 2 3
2 3 974.20 -1 15.39 0 0 0.00 / 412.88 2 3
3 7 2005.72 30 14.74 3087 1365 1.59 / 414.25 2 5
4 13 1586.60 20 14.74 2556 754 2.34 / 415.00 2 4
5 13 999.36 20 14.84 1781 529 2.87 / 415.53 2 7
6 13 427.52 20 14.98 971 291 3.16 / 415.82 2 6
7 13 59.28 20 15.09 390 118 3.28 / 415.94 2 3
8 8 0.00 165 15.07 304 756 4.03 / 416.69 2 3
9 14 0.00 30 15.05 301 136 4.17 / 416.83 2 2
Average= 4.05
(KJ/cycle)

Cycle 101 GMT 24/ 1/2022 13:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 31 15.04 452 211 0.21 / 408.79 2 3
2 3 1021.68 1 15.11 1885 28 0.24 / 408.82 2 5
3 7 2003.48 30 14.75 3075 1361 1.60 / 410.18 2 4
4 13 1605.08 20 14.75 2581 761 2.36 / 410.94 2 4
5 13 1024.16 20 14.83 1815 538 2.90 / 411.48 2 6
6 13 449.76 20 14.97 1004 301 3.20 / 411.78 2 7
7 13 72.44 20 15.09 399 120 3.32 / 411.90 2 3
8 8 0.08 165 15.07 306 761 4.08 / 412.66 2 4
Average= 4.05
(KJ/cycle)

Cycle 100 GMT 14/ 1/2022 15:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 31 15.04 466 217 0.22 / 404.75 2 3
2 7 2003.88 30 14.74 3079 1362 1.58 / 406.12 2 4
3 13 1481.36 20 14.76 2422 715 2.29 / 406.83 2 6
4 13 1061.40 20 14.82 1865 553 2.85 / 407.38 2 6
5 13 463.00 20 14.97 1026 307 3.15 / 407.69 2 7
6 13 71.24 20 15.09 401 121 3.27 / 407.81 2 3
7 8 0.00 165 15.07 308 766 4.04 / 408.58 2 3
Average= 4.05
(KJ/cycle)

Cycle 99 GMT 4/ 1/2022 18: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 31 15.03 472 220 0.22 / 400.64 2 3
2 7 2008.24 30 14.75 3102 1373 1.59 / 402.01 2 4
3 13 1735.60 20 14.72 2757 812 2.40 / 402.82 2 5
4 13 995.00 20 14.84 1779 528 2.93 / 403.35 2 7
5 13 439.08 20 14.98 991 297 3.23 / 403.65 2 7
6 13 75.72 20 15.09 407 123 3.35 / 403.77 2 3
7 8 0.00 165 15.07 309 768 4.12 / 404.54 2 3
Average= 4.05
(KJ/cycle)

Cycle 98 GMT 25/12/2021 19:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 30 15.04 461 208 0.21 / 396.51 2 3
2 10 1020.04 2 15.02 1858 56 0.26 / 396.56 2 4
3 3 979.64 -1 15.39 0 0 0.06 / 396.56 2 4
4 7 2003.08 30 14.76 3077 1362 1.63 / 397.93 2 4
5 13 1589.16 20 14.75 2560 755 2.38 / 398.68 2 5
6 13 1018.24 20 14.84 1811 538 2.92 / 399.22 2 6
7 13 445.64 20 14.98 1007 302 3.22 / 399.52 2 7
8 13 78.64 20 15.09 417 126 3.35 / 399.65 2 3
9 8 0.12 165 15.07 310 771 4.12 / 400.42 2 3
Average= 4.04
(KJ/cycle)

Cycle 97 GMT 15/12/2021 21:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 30 15.05 459 207 0.21 / 392.49 2 3
2 7 2005.64 30 14.75 3074 1360 1.57 / 393.85 2 4
3 13 1593.16 20 14.75 2560 755 2.32 / 394.61 2 5
4 13 896.08 20 14.87 1639 487 2.81 / 395.10 2 7
5 13 462.40 20 14.97 1031 309 3.12 / 395.40 2 7
6 13 70.76 20 15.09 408 123 3.24 / 395.53 2 3
7 8 0.00 165 15.07 310 771 4.01 / 396.30 2 3
Average= 4.04
(KJ/cycle)

Cycle 96 GMT 5/12/2021 23:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 30 15.04 468 211 0.21 / 388.44 2 3
2 7 2002.88 30 14.75 3089 1367 1.58 / 389.80 2 5
3 13 1609.16 20 14.74 2598 766 2.34 / 390.57 2 6
4 13 1013.88 20 14.84 1801 535 2.88 / 391.10 2 5
5 13 435.12 20 14.98 984 295 3.17 / 391.40 2 7
6 13 66.56 20 15.09 401 121 3.29 / 391.52 2 3
7 8 -0.08 165 15.08 308 766 4.06 / 392.29 2 5
Average= 4.04
(KJ/cycle)

Cycle 95 GMT 26/11/2021 2: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 30 15.05 470 212 0.21 / 384.33 2 3
2 7 2006.08 30 14.75 3089 1367 1.58 / 385.69 2 4
3 13 1738.84 20 14.73 2755 812 2.39 / 386.50 2 5
4 13 993.96 20 14.85 1783 530 2.92 / 387.03 2 7
5 13 433.48 20 14.98 985 295 3.22 / 387.33 2 7
6 13 68.24 20 15.09 405 122 3.34 / 387.45 2 3
7 8 0.08 165 15.08 311 774 4.11 / 388.23 2 2
Average= 4.04
(KJ/cycle)

Cycle 94 GMT 16/11/2021 4:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 29 15.04 475 207 0.21 / 380.05 2 3
2 3 1022.24 1 15.11 1897 29 0.24 / 380.08 2 4
3 7 2005.72 31 14.74 3094 1414 1.65 / 381.49 2 4
4 13 1578.00 20 14.75 2548 752 2.40 / 382.24 2 6
5 13 999.68 20 14.84 1788 531 2.93 / 382.77 2 6
6 13 427.68 20 14.99 977 293 3.22 / 383.07 2 7
7 13 62.64 20 15.09 398 120 3.34 / 383.19 2 3
8 8 0.04 165 15.07 315 783 4.13 / 383.97 2 4
9 14 0.04 30 15.05 316 143 4.27 / 384.11 2 4
Average= 4.04
(KJ/cycle)

Cycle 93 GMT 6/11/2021 6: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 29 15.04 489 213 0.21 / 375.89 2 3
2 7 2007.20 30 14.75 3096 1370 1.58 / 377.26 2 5
3 13 1603.32 20 14.75 2581 761 2.34 / 378.02 2 6
4 13 1017.40 20 14.84 1812 538 2.88 / 378.55 2 7
5 13 447.00 20 14.98 1009 302 3.18 / 378.86 2 7
6 13 71.36 20 15.09 404 122 3.31 / 378.98 2 3
7 13 19.12 20 15.10 334 101 3.41 / 379.08 2 2
8 8 0.04 165 15.07 307 763 4.17 / 379.84 2 3
Average= 4.04
(KJ/cycle)

Cycle 92 GMT 27/10/2021 8:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 29 15.04 477 208 0.21 / 371.72 2 3
2 7 2010.80 30 14.75 3101 1372 1.58 / 373.09 2 4
3 13 1594.68 20 14.75 2571 758 2.34 / 373.85 2 6
4 13 1009.00 20 14.84 1805 536 2.87 / 374.39 2 6
5 13 430.12 20 14.99 981 294 3.17 / 374.68 2 7
6 13 65.56 20 15.10 401 121 3.29 / 374.80 2 3
7 13 16.72 20 15.10 332 100 3.39 / 374.90 2 2
8 8 -0.04 165 15.07 309 768 4.16 / 375.67 2 3
Average= 4.04
(KJ/cycle)

Cycle 91 GMT 17/10/2021 10:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 29 15.05 466 203 0.20 / 367.58 2 3
2 7 2009.40 30 14.74 3090 1366 1.57 / 368.95 2 5
3 13 1583.60 20 14.75 2560 755 2.32 / 369.70 2 6
4 13 990.08 20 14.85 1770 526 2.85 / 370.23 2 7
5 13 414.60 20 14.99 957 287 3.14 / 370.52 2 7
6 13 60.36 20 15.10 394 119 3.26 / 370.64 2 3
7 13 34.24 20 15.10 357 108 3.36 / 370.74 2 3
8 8 0.00 165 15.07 310 771 4.14 / 371.51 2 2
Average= 4.04
(KJ/cycle)

Cycle 90 GMT 7/10/2021 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 29 15.05 460 201 0.20 / 363.54 2 3
2 7 2004.32 30 14.75 3080 1363 1.56 / 364.90 2 4
3 13 1598.40 20 14.75 2572 759 2.32 / 365.66 2 6
4 13 1014.52 20 14.84 1799 534 2.86 / 366.19 2 7
5 13 438.64 20 14.98 990 297 3.15 / 366.49 2 7
6 13 66.08 20 15.10 401 121 3.27 / 366.61 2 3
7 8 0.04 165 15.08 308 766 4.04 / 367.38 2 2
Average= 4.04
(KJ/cycle)

Cycle 89 GMT 27/ 9/2021 14:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 30 15.04 462 208 0.21 / 359.25 2 3
2 3 982.32 -1 15.40 0 0 0.00 / 359.25 2 3
3 7 2005.60 30 14.75 3086 1366 1.57 / 360.62 2 5
4 13 1594.20 20 14.76 2572 759 2.33 / 361.38 2 5
5 13 1020.36 20 14.84 1807 536 2.87 / 361.91 2 7
6 13 449.52 20 14.98 1007 302 3.17 / 362.22 2 7
7 13 73.68 20 15.10 410 124 3.30 / 362.34 2 3
8 13 21.72 20 15.11 335 101 3.40 / 362.44 2 2
9 8 0.08 165 15.08 305 759 4.16 / 363.20 2 3
10 14 0.08 30 15.05 305 138 4.29 / 363.34 2 3
Average= 4.04
(KJ/cycle)

Cycle 88 GMT 17/ 9/2021 16:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 30 15.05 458 207 0.21 / 355.12 2 3
2 7 2004.04 30 14.75 3089 1367 1.57 / 356.48 2 4
3 13 1590.32 20 14.75 2567 757 2.33 / 357.24 2 5
4 13 994.64 20 14.85 1779 528 2.86 / 357.77 2 6
5 13 419.48 20 14.99 962 288 3.15 / 358.06 2 7
6 13 66.08 20 15.10 402 121 3.27 / 358.18 2 3
7 13 19.88 20 15.10 335 101 3.37 / 358.28 2 2
8 8 0.08 165 15.08 307 764 4.13 / 359.05 2 4
Average= 4.03
(KJ/cycle)

Cycle 87 GMT 7/ 9/2021 18:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 29 15.05 456 199 0.20 / 350.95 2 3
2 3 1015.16 1 15.12 1875 28 0.23 / 350.98 2 5
3 7 2010.32 30 14.74 3094 1368 1.60 / 352.35 2 3
4 13 1596.92 20 14.75 2579 761 2.36 / 353.11 2 5
5 13 1012.96 20 14.85 1800 535 2.89 / 353.65 2 7
6 13 425.36 20 14.99 973 292 3.18 / 353.94 2 8
7 13 64.08 20 15.10 396 120 3.30 / 354.06 2 3
8 13 18.48 20 15.10 328 99 3.40 / 354.16 2 2
9 8 -0.04 165 15.08 303 754 4.16 / 354.91 2 3
Average= 4.03
(KJ/cycle)

Cycle 86 GMT 28/ 8/2021 20:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 29 15.05 458 200 0.20 / 346.97 2 3
2 7 2010.56 30 14.75 3092 1368 1.57 / 348.34 2 4
3 13 1489.04 20 14.77 2426 717 2.28 / 349.06 2 5
4 13 929.76 20 14.87 1687 502 2.79 / 349.56 2 7
5 13 493.76 20 14.96 1071 320 3.11 / 349.88 2 7
6 13 41.36 20 15.10 368 111 3.22 / 349.99 2 3
7 8 -0.04 165 15.08 307 764 3.98 / 350.76 2 2
Average= 4.03
(KJ/cycle)

Cycle 85 GMT 18/ 8/2021 22:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 29 15.04 464 202 0.20 / 342.85 2 3
2 7 2003.64 30 14.76 3083 1365 1.57 / 344.21 2 4
3 13 1594.12 20 14.76 2569 758 2.33 / 344.97 2 5
4 13 1006.12 20 14.85 1792 532 2.86 / 345.50 2 7
5 13 439.40 20 14.99 991 297 3.16 / 345.80 2 6
6 13 66.60 20 15.10 392 118 3.27 / 345.92 2 3
7 13 18.16 20 15.11 323 98 3.37 / 346.02 2 2
8 8 0.12 165 15.08 304 756 4.13 / 346.77 2 3
Average= 4.03
(KJ/cycle)

Cycle 84 GMT 9/ 8/2021 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 30 15.06 462 209 0.21 / 338.76 2 3
2 3 982.52 -1 15.40 0 0 0.00 / 338.76 2 3
3 7 2004.76 30 14.75 3082 1364 1.57 / 340.12 2 5
4 13 1585.04 20 14.76 2563 757 2.33 / 340.88 2 6
5 13 884.12 20 14.88 1628 484 2.81 / 341.36 2 7
6 13 451.76 20 14.98 1013 303 3.12 / 341.66 2 7
7 13 65.64 20 15.10 397 120 3.24 / 341.78 2 3
8 13 15.96 20 15.11 327 99 3.34 / 341.88 2 2
9 8 0.08 165 15.07 307 763 4.10 / 342.65 2 3
Average= 4.03
(KJ/cycle)

Cycle 83 GMT 30/ 7/2021 2:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 30 15.04 472 213 0.21 / 334.53 2 3
2 7 2005.04 31 14.76 3092 1415 1.63 / 335.94 2 4
3 13 1598.04 20 14.77 2573 760 2.39 / 336.70 2 5
4 13 1030.96 20 14.86 1826 543 2.93 / 337.25 2 6
5 13 468.84 20 14.99 1035 310 3.24 / 337.56 2 7
6 13 87.60 20 15.11 415 125 3.37 / 337.68 2 3
7 13 20.36 20 15.12 333 101 3.47 / 337.78 2 2
8 8 0.00 165 15.09 307 764 4.23 / 338.55 2 5
Average= 4.03
(KJ/cycle)

Cycle 82 GMT 20/ 7/2021 4:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 30 15.04 462 208 0.21 / 330.48 2 3
2 7 2004.04 30 14.76 3080 1364 1.57 / 331.84 2 4
3 13 1591.64 20 14.76 2561 756 2.33 / 332.60 2 5
4 13 1012.92 20 14.85 1804 536 2.86 / 333.14 2 6
5 13 426.92 20 14.99 974 292 3.16 / 333.43 2 7
6 13 62.72 20 15.10 392 118 3.27 / 333.55 2 3
7 8 0.04 165 15.08 309 769 4.04 / 334.32 2 3
Average= 4.03
(KJ/cycle)

Cycle 81 GMT 10/ 7/2021 7: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 30 15.05 461 208 0.21 / 326.44 2 3
2 7 2003.20 30 14.76 3097 1371 1.58 / 327.81 2 4
3 13 1571.00 20 14.77 2542 751 2.33 / 328.57 2 5
4 13 999.60 20 14.85 1788 531 2.86 / 329.10 2 7
5 13 410.72 20 15.00 953 286 3.15 / 329.38 2 7
6 13 58.60 20 15.10 395 119 3.27 / 329.50 2 3
7 8 0.12 165 15.08 310 771 4.04 / 330.27 2 4
Average= 4.03
(KJ/cycle)

Cycle 80 GMT 30/ 6/2021 9:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 30 15.05 462 209 0.21 / 322.35 2 3
2 7 2009.04 31 14.76 3090 1414 1.62 / 323.77 2 5
3 13 1597.72 20 14.76 2569 758 2.38 / 324.52 2 6
4 13 1006.16 20 14.85 1791 532 2.91 / 325.06 2 6
5 13 425.36 20 14.99 969 291 3.20 / 325.35 2 6
6 13 63.28 20 15.10 394 119 3.32 / 325.47 2 3
7 8 0.16 165 15.08 309 769 4.09 / 326.23 2 3
Average= 4.03
(KJ/cycle)

Cycle 79 GMT 20/ 6/2021 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 30 15.05 461 208 0.21 / 318.31 2 2
2 7 2003.64 30 14.76 3090 1368 1.58 / 319.68 2 5
3 13 1592.28 20 14.77 2568 759 2.33 / 320.44 2 6
4 13 997.72 20 14.86 1781 529 2.86 / 320.97 2 7
5 13 422.16 20 14.99 964 289 3.15 / 321.26 2 6
6 13 62.16 20 15.10 393 119 3.27 / 321.37 2 3
7 8 0.04 165 15.08 309 769 4.04 / 322.14 2 3
Average= 4.03
(KJ/cycle)

Cycle 78 GMT 10/ 6/2021 13:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 30 15.06 462 209 0.21 / 314.28 2 3
2 7 2003.00 30 14.77 3079 1364 1.57 / 315.65 2 4
3 13 1586.68 20 14.77 2565 758 2.33 / 316.40 2 6
4 13 994.88 20 14.86 1774 527 2.86 / 316.93 2 7
5 13 412.48 20 15.00 950 285 3.14 / 317.22 2 6
6 13 61.16 20 15.10 390 118 3.26 / 317.33 2 3
7 8 0.16 165 15.08 309 769 4.03 / 318.10 2 3
Average= 4.03
(KJ/cycle)

Cycle 77 GMT 31/ 5/2021 15:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 30 15.05 467 211 0.21 / 310.21 2 3
2 7 2001.92 30 14.77 3082 1366 1.58 / 311.57 2 5
3 13 1715.68 20 14.76 2723 804 2.38 / 312.38 2 5
4 13 975.60 20 14.87 1756 522 2.90 / 312.90 2 7
5 13 409.00 20 15.01 952 286 3.19 / 313.19 2 7
6 13 62.60 20 15.11 394 119 3.31 / 313.30 2 3
7 8 0.00 165 15.08 309 769 4.08 / 314.07 2 3
Average= 4.03
(KJ/cycle)

Cycle 76 GMT 21/ 5/2021 17:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 31 15.05 465 217 0.22 / 306.16 2 3
2 7 2003.72 30 14.78 3093 1371 1.59 / 307.53 2 4
3 13 1593.20 20 14.78 2574 761 2.35 / 308.29 2 5
4 13 999.40 20 14.86 1781 529 2.88 / 308.82 2 6
5 13 424.40 20 15.00 969 291 3.17 / 309.11 2 7
6 13 58.20 20 15.11 391 118 3.29 / 309.23 2 3
7 8 0.12 165 15.09 309 769 4.06 / 310.00 2 3
Average= 4.03
(KJ/cycle)

Cycle 75 GMT 11/ 5/2021 19:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 31 15.05 460 215 0.21 / 302.05 2 3
2 7 2005.88 31 14.78 3087 1414 1.63 / 303.47 2 4
3 13 1593.48 20 14.78 2576 761 2.39 / 304.23 2 6
4 13 1003.60 20 14.87 1794 534 2.92 / 304.76 2 6
5 13 421.64 20 15.00 970 291 3.22 / 305.05 2 6
6 13 59.56 20 15.11 390 118 3.33 / 305.17 2 3
7 8 0.04 165 15.09 309 769 4.10 / 305.94 2 3
Average= 4.03
(KJ/cycle)

Cycle 74 GMT 1/ 5/2021 21:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 31 15.05 467 218 0.22 / 297.99 2 3
2 7 2002.64 30 14.79 3084 1368 1.59 / 299.36 2 4
3 13 1594.76 20 14.78 2573 761 2.35 / 300.12 2 5
4 13 1014.76 20 14.87 1801 536 2.88 / 300.65 2 6
5 13 441.40 20 15.00 997 299 3.18 / 300.95 2 6
6 13 67.76 20 15.11 395 119 3.30 / 301.07 2 3
7 8 0.08 165 15.09 308 767 4.07 / 301.84 2 3
Average= 4.02
(KJ/cycle)

Cycle 73 GMT 21/ 4/2021 23:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 29 15.06 467 204 0.20 / 293.83 2 3
2 10 1015.04 3 15.04 1829 83 0.29 / 293.91 2 3
3 3 976.72 -1 15.40 0 0 0.08 / 293.91 2 3
4 7 2006.72 30 14.79 3090 1371 1.66 / 295.28 2 5
5 13 1601.04 20 14.79 2574 761 2.42 / 296.04 2 6
6 13 1014.20 20 14.87 1807 537 2.96 / 296.58 2 7
7 13 438.68 20 15.01 990 297 3.25 / 296.88 2 7
8 13 69.52 20 15.12 405 122 3.38 / 297.00 2 3
9 8 0.08 165 15.10 310 772 4.15 / 297.77 2 2
Average= 4.02
(KJ/cycle)

Cycle 72 GMT 12/ 4/2021 1:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.48 29 15.06 494 216 0.22 / 289.69 2 3
2 7 2003.28 30 14.79 3085 1369 1.58 / 291.06 2 4
3 13 1722.40 20 14.77 2726 805 2.39 / 291.86 2 5
4 13 980.12 20 14.88 1757 523 2.91 / 292.39 2 6
5 13 522.20 20 14.98 1114 334 3.25 / 292.72 2 6
6 13 97.52 20 15.11 438 132 3.38 / 292.85 2 3
7 8 0.04 165 15.09 309 769 4.15 / 293.62 2 4
Average= 4.02
(KJ/cycle)

Cycle 71 GMT 2/ 4/2021 3:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 31 15.06 501 234 0.23 / 285.60 2 3
2 3 946.92 -2 15.41 0 0 0.00 / 285.60 2 3
3 7 2004.32 31 14.80 3081 1414 1.65 / 287.02 2 4
4 13 1594.88 20 14.80 2572 761 2.41 / 287.78 2 5
5 13 1003.04 20 14.88 1792 533 2.94 / 288.31 2 7
6 13 415.68 20 15.02 956 287 3.23 / 288.60 2 8
7 13 57.40 20 15.13 376 114 3.34 / 288.71 2 3
8 8 -0.08 165 15.10 306 762 4.11 / 289.47 2 2
Average= 4.02
(KJ/cycle)

Cycle 70 GMT 23/ 3/2021 5:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 31 15.06 451 211 0.21 / 281.37 2 3
2 7 2009.20 30 14.81 3106 1380 1.59 / 282.75 2 4
3 13 1743.32 20 14.77 2762 816 2.41 / 283.57 2 5
4 13 1114.28 20 14.86 1936 575 2.98 / 284.14 2 7
5 13 505.20 20 15.00 1092 328 3.31 / 284.47 2 7
6 13 96.24 20 15.12 439 133 3.44 / 284.60 2 4
7 8 0.12 165 15.11 307 765 4.21 / 285.37 2 3
Average= 4.02
(KJ/cycle)

Cycle 69 GMT 13/ 3/2021 8: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 31 15.07 451 211 0.21 / 277.28 2 2
2 7 2004.12 30 14.86 3088 1377 1.59 / 278.66 2 5
3 13 1474.76 20 14.87 2419 719 2.31 / 279.38 2 5
4 13 917.28 20 14.92 1674 500 2.81 / 279.88 2 6
5 13 365.76 20 15.05 884 266 3.07 / 280.14 2 6
6 13 49.36 20 15.13 374 113 3.19 / 280.25 2 3
7 8 0.12 165 15.10 308 767 3.95 / 281.02 2 2
8 14 0.12 30 15.08 306 138 4.09 / 281.16 2 2
Average= 4.02
(KJ/cycle)

Cycle 68 GMT 3/ 3/2021 10: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 29 15.08 457 200 0.20 / 273.12 2 3
2 10 1016.56 3 15.05 1847 83 0.28 / 273.20 2 4
3 3 973.36 -1 15.42 0 0 0.08 / 273.20 2 4
4 7 2004.40 30 14.87 3085 1376 1.66 / 274.58 2 4
5 13 1470.00 20 14.88 2410 717 2.38 / 275.30 2 5
6 13 912.40 20 14.94 1663 497 2.87 / 275.79 2 7
7 13 357.76 20 15.05 872 262 3.14 / 276.05 2 8
8 13 52.32 20 15.14 377 114 3.25 / 276.17 2 3
9 8 0.04 165 15.11 306 763 4.01 / 276.93 2 4
10 14 0.04 30 15.09 304 138 4.15 / 277.07 2 3
Average= 4.02
(KJ/cycle)

Cycle 67 GMT 21/ 2/2021 11:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.20 31 15.07 502 235 0.23 / 268.94 2 3
2 3 945.08 -2 15.42 0 0 0.00 / 268.94 2 3
3 7 2009.28 30 14.87 3085 1376 1.61 / 270.31 2 5
4 13 1561.36 20 14.87 2519 749 2.36 / 271.06 2 5
5 13 1005.68 20 14.92 1794 535 2.90 / 271.60 2 6
6 13 420.52 20 15.04 966 291 3.19 / 271.89 2 7
7 13 66.12 20 15.14 396 120 3.31 / 272.01 2 3
8 8 0.16 165 15.12 309 771 4.08 / 272.78 2 2
9 14 0.16 30 15.09 307 139 4.22 / 272.92 2 3
Average= 4.01
(KJ/cycle)

Cycle 66 GMT 11/ 2/2021 13:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 31 15.09 466 218 0.22 / 264.90 2 3
2 7 2002.00 30 14.87 3085 1376 1.59 / 266.28 2 5
3 13 1570.48 20 14.87 2540 755 2.35 / 267.03 2 5
4 13 855.76 20 14.96 1589 475 2.83 / 267.51 2 7
5 13 429.12 20 15.04 982 295 3.12 / 267.81 2 7
6 13 60.60 20 15.14 393 119 3.24 / 267.92 2 2
7 8 0.04 165 15.12 312 778 4.02 / 268.70 2 3
Average= 4.01
(KJ/cycle)

Cycle 65 GMT 1/ 2/2021 15:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 31 15.09 459 215 0.21 / 260.78 2 3
2 3 1023.92 1 15.14 1896 29 0.24 / 260.81 2 5
3 7 2003.52 31 14.87 3091 1425 1.67 / 262.23 2 4
4 13 1582.08 20 14.87 2562 762 2.43 / 263.00 2 5
5 13 976.84 20 14.94 1749 523 2.95 / 263.52 2 6
6 13 398.80 20 15.06 931 280 3.23 / 263.80 2 7
7 13 62.60 20 15.15 394 119 3.35 / 263.92 2 3
8 8 -0.08 165 15.13 307 766 4.12 / 264.69 2 4
Average= 4.01
(KJ/cycle)

Cycle 64 GMT 22/ 1/2021 17:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 31 15.10 446 209 0.21 / 256.72 2 2
2 7 2007.44 31 14.88 3090 1425 1.63 / 258.15 2 5
3 13 1477.68 20 14.89 2428 723 2.36 / 258.87 2 6
4 13 914.20 20 14.95 1662 497 2.85 / 259.37 2 7
5 13 456.32 20 15.04 1017 306 3.16 / 259.67 2 8
6 13 72.08 20 15.14 407 123 3.28 / 259.80 2 3
7 8 0.12 165 15.13 308 769 4.05 / 260.57 2 3
Average= 4.01
(KJ/cycle)

Cycle 63 GMT 12/ 1/2021 20: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 30 15.10 460 208 0.21 / 252.51 2 2
2 7 2003.00 30 14.89 3085 1378 1.59 / 253.89 2 6
3 13 1591.24 20 14.88 2571 765 2.35 / 254.65 2 5
4 13 1011.36 20 14.93 1803 538 2.89 / 255.19 2 6
5 13 428.08 20 15.06 970 292 3.18 / 255.48 2 6
6 13 71.92 20 15.15 407 123 3.31 / 255.61 2 3
7 8 0.08 165 15.14 307 767 4.07 / 256.38 2 2
8 14 0.08 30 15.11 306 139 4.21 / 256.51 2 3
Average= 4.01
(KJ/cycle)

Cycle 62 GMT 2/ 1/2021 22: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 30 15.11 465 211 0.21 / 248.41 2 3
2 3 1035.48 1 15.14 1911 29 0.24 / 248.43 2 5
3 7 2004.56 30 14.89 3089 1380 1.62 / 249.81 2 4
4 13 1592.48 20 14.88 2576 767 2.39 / 250.58 2 5
5 13 1004.04 20 14.94 1788 534 2.92 / 251.12 2 7
6 13 424.28 20 15.06 970 292 3.21 / 251.41 2 8
7 13 69.16 20 15.16 407 123 3.34 / 251.53 2 3
8 8 0.08 165 15.14 309 772 4.11 / 252.30 2 3
Average= 4.00
(KJ/cycle)

Cycle 61 GMT 24/12/2020 0: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 29 15.11 465 204 0.20 / 244.32 2 3
2 3 1027.44 1 15.15 1894 29 0.23 / 244.35 2 4
3 7 2002.28 30 14.88 3090 1379 1.61 / 245.73 2 4
4 13 1589.84 20 14.88 2567 764 2.38 / 246.50 2 5
5 13 896.28 20 14.97 1645 493 2.87 / 246.99 2 7
6 13 457.24 20 15.05 1018 306 3.17 / 247.30 2 7
7 13 67.80 20 15.16 403 122 3.30 / 247.42 2 3
8 8 -0.24 165 15.14 311 777 4.07 / 248.19 2 3
Average= 4.00
(KJ/cycle)

Cycle 60 GMT 14/12/2020 1:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 30 15.12 461 209 0.21 / 240.26 2 3
2 7 2002.68 30 14.89 3089 1380 1.59 / 241.64 2 5
3 13 1588.00 20 14.88 2572 765 2.35 / 242.40 2 6
4 13 993.44 20 14.95 1781 533 2.89 / 242.93 2 7
5 13 408.60 20 15.07 949 286 3.17 / 243.22 2 7
6 13 64.40 20 15.17 399 121 3.29 / 243.34 2 3
7 8 0.16 165 15.15 312 780 4.07 / 244.12 2 4
Average= 4.00
(KJ/cycle)

Cycle 59 GMT 4/12/2020 4: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 29 15.11 471 206 0.21 / 236.12 2 3
2 3 1016.60 1 15.17 1909 29 0.24 / 236.14 2 5
3 7 2003.76 31 14.89 3091 1427 1.66 / 237.57 2 4
4 13 1592.48 20 14.88 2569 765 2.43 / 238.34 2 5
5 13 996.40 20 14.95 1781 533 2.96 / 238.87 2 6
6 13 402.96 20 15.08 943 284 3.24 / 239.15 2 7
7 13 63.16 20 15.17 395 120 3.36 / 239.27 2 3
8 8 0.00 165 15.15 310 775 4.14 / 240.05 2 3
Average= 4.00
(KJ/cycle)

Cycle 58 GMT 24/11/2020 6: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 29 15.12 464 203 0.20 / 232.02 2 2
2 7 2005.84 30 14.90 3097 1384 1.59 / 233.40 2 4
3 13 1587.68 20 14.89 2567 764 2.35 / 234.17 2 6
4 13 1015.72 20 14.95 1808 541 2.89 / 234.71 2 6
5 13 434.96 20 15.07 988 298 3.19 / 235.01 2 7
6 13 69.28 20 15.17 407 123 3.31 / 235.13 2 3
7 8 0.04 165 15.15 312 780 4.09 / 235.91 2 3
Average= 4.00
(KJ/cycle)

Cycle 57 GMT 14/11/2020 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 29 15.13 463 203 0.20 / 227.96 2 2
2 7 2006.28 30 14.90 3102 1387 1.59 / 229.35 2 4
3 13 1583.48 20 14.89 2564 764 2.35 / 230.11 2 4
4 13 978.36 20 14.96 1761 527 2.88 / 230.64 2 7
5 13 398.48 20 15.09 937 283 3.16 / 230.92 2 7
6 13 60.92 20 15.19 391 119 3.28 / 231.04 2 3
7 8 0.16 165 15.16 309 773 4.05 / 231.81 2 3
Average= 4.00
(KJ/cycle)

Cycle 56 GMT 4/11/2020 10: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 29 15.12 470 206 0.21 / 223.83 2 3
2 7 2003.84 30 14.89 3083 1377 1.58 / 225.20 2 5
3 13 1584.88 20 14.89 2566 764 2.35 / 225.97 2 5
4 13 980.00 20 14.97 1762 528 2.87 / 226.49 2 8
5 13 385.48 20 15.10 917 277 3.15 / 226.77 2 6
6 13 58.04 20 15.19 392 119 3.27 / 226.89 2 3
7 13 15.92 20 15.19 326 99 3.37 / 226.99 2 2
8 8 0.00 165 15.16 308 770 4.14 / 227.76 2 2
Average= 4.00
(KJ/cycle)

Cycle 55 GMT 25/10/2020 12:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 29 15.13 461 202 0.20 / 219.65 2 3
2 7 2005.00 30 14.91 3094 1384 1.59 / 221.04 2 4
3 13 1579.88 20 14.90 2560 763 2.35 / 221.80 2 6
4 13 982.96 20 14.97 1765 528 2.88 / 222.33 2 6
5 13 409.04 20 15.10 949 287 3.16 / 222.62 2 6
6 13 65.80 20 15.19 398 121 3.29 / 222.74 2 3
7 13 36.24 20 15.19 360 109 3.39 / 222.85 2 3
8 8 0.08 165 15.16 309 773 4.17 / 223.62 2 4
Average= 3.99
(KJ/cycle)

Cycle 54 GMT 15/10/2020 14:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 29 15.14 461 202 0.20 / 215.43 2 3
2 10 1002.88 2 15.12 1828 55 0.26 / 215.49 2 4
3 3 953.40 -2 15.45 0 0 0.06 / 215.49 2 4
4 7 2002.04 30 14.91 3096 1385 1.64 / 216.87 2 4
5 13 1584.52 20 14.90 2556 762 2.40 / 217.64 2 6
6 13 1003.16 20 14.97 1789 536 2.94 / 218.17 2 7
7 13 422.16 20 15.10 965 291 3.23 / 218.46 2 7
8 13 67.36 20 15.19 403 122 3.35 / 218.59 2 3
9 13 21.88 20 15.20 332 101 3.45 / 218.69 2 2
10 8 0.12 165 15.17 306 766 4.22 / 219.45 2 3
Average= 3.99
(KJ/cycle)

Cycle 53 GMT 5/10/2020 16:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 29 15.14 461 202 0.20 / 211.29 2 3
2 7 2006.12 30 14.90 3097 1384 1.59 / 212.68 2 4
3 13 1581.00 20 14.90 2552 760 2.35 / 213.44 2 5
4 13 978.04 20 14.98 1757 526 2.87 / 213.97 2 7
5 13 398.76 20 15.10 928 280 3.15 / 214.25 2 7
6 13 61.80 20 15.20 392 119 3.27 / 214.37 2 3
7 13 19.44 20 15.20 330 100 3.37 / 214.47 2 2
8 8 0.08 165 15.17 306 766 4.14 / 215.23 2 3
Average= 3.99
(KJ/cycle)

Cycle 52 GMT 25/ 9/2020 18:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 29 15.14 460 202 0.20 / 207.10 2 3
2 3 1025.00 1 15.17 1889 29 0.23 / 207.13 2 4
3 7 2003.12 30 14.92 3100 1388 1.62 / 208.51 2 4
4 13 1586.28 20 14.91 2571 767 2.38 / 209.28 2 5
5 13 993.92 20 14.98 1783 534 2.92 / 209.81 2 7
6 13 410.76 20 15.10 954 288 3.21 / 210.10 2 7
7 13 68.52 20 15.20 402 122 3.33 / 210.22 2 3
8 13 22.60 20 15.20 334 102 3.43 / 210.33 2 2
9 8 0.20 165 15.17 306 766 4.20 / 211.09 2 4
Average= 3.98
(KJ/cycle)

Cycle 51 GMT 15/ 9/2020 20:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 29 15.15 465 204 0.20 / 202.90 2 2
2 7 2006.76 31 14.91 3100 1433 1.64 / 204.33 2 4
3 13 1575.24 20 14.91 2549 760 2.40 / 205.09 2 6
4 13 989.24 20 14.98 1778 533 2.93 / 205.62 2 6
5 13 399.80 20 15.11 934 282 3.21 / 205.91 2 6
6 13 61.52 20 15.20 395 120 3.33 / 206.03 2 2
7 13 21.56 20 15.21 331 101 3.43 / 206.13 2 2
8 8 -0.04 165 15.18 307 769 4.20 / 206.90 2 3
Average= 3.98
(KJ/cycle)

Cycle 50 GMT 5/ 9/2020 22:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 29 15.15 462 203 0.20 / 198.73 2 3
2 3 981.96 -1 15.46 0 0 0.00 / 198.73 2 3
3 7 2003.64 30 14.91 3088 1381 1.58 / 200.12 2 4
4 13 1583.88 20 14.91 2564 765 2.35 / 200.88 2 6
5 13 995.12 20 14.98 1785 535 2.88 / 201.42 2 7
6 13 399.00 20 15.11 936 283 3.17 / 201.70 2 7
7 13 62.64 20 15.21 396 120 3.29 / 201.82 2 3
8 13 18.68 20 15.21 332 101 3.39 / 201.92 2 2
9 8 0.12 165 15.18 309 774 4.16 / 202.69 2 3
Average= 3.97
(KJ/cycle)

Cycle 49 GMT 27/ 8/2020 0:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 29 15.15 455 200 0.20 / 194.57 2 2
2 7 2003.20 30 14.93 3087 1383 1.58 / 195.95 2 4
3 13 1589.08 20 14.92 2572 767 2.35 / 196.72 2 6
4 13 992.92 20 14.99 1774 532 2.88 / 197.25 2 6
5 13 412.12 20 15.12 955 289 3.17 / 197.54 2 6
6 13 68.48 20 15.21 400 122 3.29 / 197.66 2 3
7 13 23.12 20 15.21 331 101 3.39 / 197.76 2 2
8 8 0.20 165 15.18 308 771 4.16 / 198.53 2 3
Average= 3.97
(KJ/cycle)

Cycle 48 GMT 17/ 8/2020 2:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 29 15.16 461 203 0.20 / 190.40 2 3
2 7 2005.76 30 14.91 3094 1384 1.59 / 191.79 2 5
3 13 1598.20 20 14.91 2584 771 2.36 / 192.56 2 6
4 13 994.80 20 14.99 1784 535 2.89 / 193.09 2 7
5 13 394.60 20 15.12 928 281 3.17 / 193.37 2 6
6 13 62.68 20 15.21 398 121 3.29 / 193.49 2 3
7 13 20.24 20 15.22 334 102 3.40 / 193.60 2 2
8 8 -0.04 165 15.19 308 772 4.17 / 194.37 2 4
Average= 3.97
(KJ/cycle)

Cycle 47 GMT 7/ 8/2020 4: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 30 15.15 457 208 0.21 / 186.23 2 3
2 7 2003.56 30 14.92 3097 1386 1.59 / 187.61 2 4
3 13 1580.16 20 14.92 2566 766 2.36 / 188.38 2 5
4 13 995.92 20 14.99 1787 536 2.90 / 188.91 2 7
5 13 406.88 20 15.12 949 287 3.18 / 189.20 2 6
6 13 63.24 20 15.22 399 121 3.30 / 189.32 2 3
7 13 18.12 20 15.22 333 101 3.41 / 189.42 2 2
8 8 0.04 165 15.19 310 777 4.18 / 190.20 2 3
Average= 3.96
(KJ/cycle)

Cycle 46 GMT 28/ 7/2020 6: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 30 15.17 458 208 0.21 / 182.09 2 2
2 7 2003.36 30 14.92 3093 1384 1.59 / 183.48 2 4
3 13 1591.64 20 14.92 2561 764 2.36 / 184.24 2 6
4 13 872.08 20 15.03 1611 484 2.84 / 184.73 2 7
5 13 431.84 20 15.12 980 296 3.14 / 185.02 2 7
6 13 56.32 20 15.22 392 119 3.26 / 185.14 2 2
7 13 14.76 20 15.22 328 100 3.36 / 185.24 2 2
8 8 -0.08 165 15.19 310 777 4.13 / 186.02 2 4
Average= 3.96
(KJ/cycle)

Cycle 45 GMT 18/ 7/2020 8: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 30 15.16 461 210 0.21 / 178.15 2 3
2 7 2003.20 30 14.93 3083 1381 1.59 / 179.53 2 4
3 13 1449.96 20 14.94 2392 715 2.31 / 180.25 2 5
4 13 898.64 20 15.02 1646 494 2.80 / 180.74 2 6
5 13 332.84 20 15.15 843 255 3.06 / 181.00 2 7
6 13 48.60 20 15.22 376 114 3.17 / 181.11 2 2
7 8 0.12 165 15.20 308 772 3.94 / 181.88 2 3
Average= 3.95
(KJ/cycle)

Cycle 44 GMT 8/ 7/2020 10: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 30 15.17 459 209 0.21 / 174.05 2 2
2 3 980.36 -1 15.48 0 0 0.00 / 174.05 2 2
3 7 2001.88 30 14.93 3098 1388 1.60 / 175.44 2 3
4 13 1591.76 20 14.93 2577 769 2.37 / 176.21 2 4
5 13 989.68 20 15.01 1778 534 2.90 / 176.74 2 6
6 13 420.16 20 15.13 963 291 3.19 / 177.03 2 7
7 13 59.12 20 15.23 396 121 3.31 / 177.15 2 2
8 8 0.04 165 15.20 314 788 4.10 / 177.94 2 3
Average= 3.95
(KJ/cycle)

Cycle 43 GMT 28/ 6/2020 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 30 15.17 468 213 0.21 / 169.98 2 3
2 7 2004.60 30 14.92 3085 1381 1.59 / 171.36 2 3
3 13 1584.92 20 14.93 2564 766 2.36 / 172.12 2 5
4 13 996.44 20 15.01 1784 536 2.89 / 172.66 2 6
5 13 399.12 20 15.13 936 283 3.18 / 172.94 2 7
6 13 56.08 20 15.23 389 118 3.30 / 173.06 2 3
7 8 0.04 165 15.21 312 783 4.08 / 173.84 2 3
Average= 3.95
(KJ/cycle)

Cycle 42 GMT 18/ 6/2020 14:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 31 15.17 466 219 0.22 / 165.88 2 3
2 3 978.36 -1 15.48 0 0 0.00 / 165.88 2 3
3 7 2001.76 30 14.94 3091 1385 1.60 / 167.27 2 3
4 13 1589.00 20 14.94 2576 770 2.37 / 168.04 2 4
5 13 996.60 20 15.01 1792 538 2.91 / 168.57 2 6
6 13 412.28 20 15.13 954 289 3.20 / 168.86 2 6
7 13 59.40 20 15.23 394 120 3.32 / 168.98 2 2
8 8 0.04 165 15.21 311 781 4.10 / 169.76 2 2
Average= 3.95
(KJ/cycle)

Cycle 41 GMT 8/ 6/2020 16:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 31 15.17 458 215 0.22 / 161.81 2 2
2 7 2001.84 30 14.93 3084 1381 1.60 / 163.19 2 3
3 13 1571.00 20 14.94 2546 761 2.36 / 163.95 2 4
4 13 968.92 20 15.02 1746 524 2.88 / 164.48 2 6
5 13 383.48 20 15.15 917 278 3.16 / 164.75 2 6
6 13 57.52 20 15.24 393 120 3.28 / 164.87 2 2
7 8 0.00 165 15.21 314 788 4.07 / 165.66 2 3
Average= 3.94
(KJ/cycle)

Cycle 40 GMT 29/ 5/2020 18:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 31 15.18 457 215 0.22 / 157.84 2 3
2 7 2006.00 30 14.94 3096 1388 1.60 / 159.22 2 3
3 13 1463.24 20 14.96 2403 719 2.32 / 159.94 2 5
4 13 909.84 20 15.03 1661 499 2.82 / 160.44 2 6
5 13 344.96 20 15.16 855 259 3.08 / 160.70 2 6
6 13 43.88 20 15.24 373 114 3.19 / 160.82 2 2
7 8 0.08 165 15.21 310 778 3.97 / 161.59 2 2
Average= 3.94
(KJ/cycle)

Cycle 39 GMT 19/ 5/2020 20: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 31 15.18 462 217 0.22 / 153.78 2 3
2 7 2001.60 30 14.93 3079 1379 1.60 / 155.16 2 3
3 13 1585.56 20 14.94 2564 766 2.36 / 155.92 2 4
4 13 974.00 20 15.03 1747 525 2.89 / 156.45 2 6
5 13 386.80 20 15.15 914 277 3.16 / 156.73 2 7
6 13 49.24 20 15.24 378 115 3.28 / 156.84 2 3
7 8 0.20 165 15.22 311 781 4.06 / 157.62 2 3
Average= 3.94
(KJ/cycle)

Cycle 38 GMT 9/ 5/2020 22: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 31 15.19 462 218 0.22 / 149.66 2 3
2 7 2003.56 30 14.95 3100 1390 1.61 / 151.05 2 3
3 13 1593.36 20 14.95 2580 771 2.38 / 151.83 2 4
4 13 1007.60 20 15.02 1801 541 2.92 / 152.37 2 6
5 13 413.56 20 15.15 960 291 3.21 / 152.66 2 6
6 13 58.96 20 15.24 391 119 3.33 / 152.78 2 3
7 8 -0.04 165 15.22 312 784 4.11 / 153.56 2 3
Average= 3.94
(KJ/cycle)

Cycle 37 GMT 30/ 4/2020 0: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 31 15.19 476 224 0.22 / 145.55 2 3
2 7 2005.84 30 14.95 3104 1392 1.62 / 146.94 2 3
3 13 1592.68 20 14.95 2573 769 2.39 / 147.71 2 4
4 13 1013.08 20 15.02 1807 543 2.93 / 148.25 2 6
5 13 423.52 20 15.15 970 294 3.22 / 148.55 2 6
6 13 56.60 20 15.24 390 119 3.34 / 148.67 2 3
7 8 0.08 165 15.22 311 781 4.12 / 149.45 2 3
Average= 3.93
(KJ/cycle)

Cycle 36 GMT 20/ 4/2020 1:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 30 15.19 458 209 0.21 / 141.41 2 2
2 3 1014.64 1 15.23 1899 29 0.24 / 141.44 2 4
3 7 2003.40 31 14.95 3087 1431 1.67 / 142.87 2 3
4 13 1589.52 20 14.95 2569 768 2.44 / 143.64 2 4
5 13 979.88 20 15.03 1761 529 2.97 / 144.17 2 6
6 13 372.84 20 15.16 897 272 3.24 / 144.44 2 7
7 13 25.36 20 15.26 339 103 3.34 / 144.55 2 2
8 8 0.04 165 15.23 310 779 4.12 / 145.32 2 3
Average= 3.93
(KJ/cycle)

Cycle 35 GMT 10/ 4/2020 4: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 30 15.19 471 215 0.21 / 137.33 2 3
2 7 2003.16 30 14.96 3088 1386 1.60 / 138.71 2 3
3 13 1590.56 20 14.95 2572 769 2.37 / 139.48 2 4
4 13 998.80 20 15.03 1782 536 2.91 / 140.02 2 6
5 13 405.72 20 15.16 947 287 3.19 / 140.31 2 7
6 13 54.36 20 15.25 387 118 3.31 / 140.42 2 2
7 8 -0.04 165 15.23 311 782 4.09 / 141.20 2 6
Average= 3.92
(KJ/cycle)

Cycle 34 GMT 31/ 3/2020 5:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 30 15.20 452 206 0.21 / 133.37 2 2
2 7 2003.60 30 14.95 3088 1385 1.59 / 134.76 2 3
3 13 1455.60 20 14.97 2392 716 2.31 / 135.48 2 5
4 13 902.16 20 15.05 1650 497 2.80 / 135.97 2 6
5 13 329.44 20 15.18 834 253 3.06 / 136.23 2 6
6 13 20.56 20 15.26 337 103 3.16 / 136.33 2 2
7 8 0.04 165 15.23 312 784 3.94 / 137.11 2 3
Average= 3.92
(KJ/cycle)

Cycle 33 GMT 21/ 3/2020 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 29 15.20 468 206 0.21 / 129.24 2 3
2 3 1047.88 2 15.19 1939 59 0.27 / 129.30 2 4
3 7 2003.64 30 14.95 3088 1385 1.65 / 130.69 2 3
4 13 1570.72 20 14.96 2543 761 2.41 / 131.45 2 4
5 13 978.20 20 15.04 1758 529 2.94 / 131.98 2 6
6 13 382.72 20 15.17 912 277 3.22 / 132.25 2 6
7 8 -0.04 165 15.24 308 774 3.99 / 133.03 2 2
8 14 -0.04 30 15.22 307 140 4.13 / 133.17 2 2
Average= 3.92
(KJ/cycle)

Cycle 32 GMT 11/ 3/2020 9:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 31 15.20 484 228 0.23 / 125.20 2 3
2 3 947.16 -2 15.51 0 0 0.00 / 125.20 2 3
3 7 2002.32 30 14.96 3088 1386 1.61 / 126.58 2 3
4 13 1568.80 20 14.97 2542 761 2.38 / 127.34 2 5
5 13 969.92 20 15.05 1742 524 2.90 / 127.87 2 6
6 13 382.48 20 15.17 908 275 3.17 / 128.14 2 6
7 13 50.64 20 15.26 379 116 3.29 / 128.26 2 2
8 8 -0.04 165 15.24 309 777 4.07 / 129.04 2 3
Average= 3.91
(KJ/cycle)

Cycle 31 GMT 1/ 3/2020 11:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 27 15.20 456 187 0.19 / 121.01 2 2
2 10 1052.68 3 15.14 1901 86 0.27 / 121.09 2 2
3 3 1050.80 2 15.19 1930 59 0.33 / 121.15 2 3
4 7 2005.60 30 14.96 3094 1389 1.72 / 122.54 2 3
5 13 1575.68 20 14.97 2550 763 2.48 / 123.30 2 4
6 13 959.20 20 15.05 1733 522 3.01 / 123.82 2 6
7 13 361.64 20 15.18 880 267 3.27 / 124.09 2 7
8 13 23.60 20 15.28 333 102 3.37 / 124.19 2 2
9 8 0.12 165 15.24 309 777 4.15 / 124.97 2 3
Average= 3.91
(KJ/cycle)

Cycle 30 GMT 20/ 2/2020 13:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 31 15.21 482 227 0.23 / 116.96 2 2
2 3 939.04 -2 15.51 0 0 0.00 / 116.96 2 2
3 3 953.08 -2 15.53 0 0 0.00 / 116.96 2 2
4 7 2007.12 30 14.97 3102 1393 1.62 / 118.35 2 2
5 13 1568.12 20 14.97 2539 760 2.38 / 119.11 2 3
6 13 971.08 20 15.05 1749 526 2.91 / 119.64 2 4
7 13 391.08 20 15.18 926 281 3.19 / 119.92 2 5
8 13 49.80 20 15.27 385 118 3.31 / 120.04 2 2
9 8 0.16 165 15.24 311 782 4.09 / 120.82 2 2
Average= 3.90
(KJ/cycle)

Cycle 29 GMT 10/ 2/2020 15:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 29 15.21 461 203 0.20 / 112.84 2 2
2 10 1002.16 2 15.16 1820 55 0.26 / 112.90 2 2
3 7 2003.96 30 14.96 3096 1389 1.65 / 114.29 2 2
4 13 1566.32 20 14.98 2540 761 2.41 / 115.05 2 3
5 13 954.88 20 15.06 1724 519 2.93 / 115.57 2 4
6 13 359.92 20 15.19 880 267 3.20 / 115.83 2 5
7 13 50.28 20 15.27 376 115 3.31 / 115.95 2 2
8 8 0.04 165 15.25 311 783 4.09 / 116.73 2 3
Average= 3.89
(KJ/cycle)

Cycle 28 GMT 31/ 1/2020 17:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 29 15.21 494 218 0.22 / 108.91 2 2
2 7 2003.48 30 14.97 3094 1390 1.61 / 110.30 2 2
3 13 1448.28 20 15.00 2393 718 2.33 / 111.01 2 3
4 13 874.60 20 15.08 1612 486 2.81 / 111.50 2 5
5 13 312.08 20 15.21 806 245 3.06 / 111.75 2 5
6 13 36.40 20 15.28 366 112 3.17 / 111.86 2 2
7 8 0.08 165 15.25 310 780 3.95 / 112.64 2 2
Average= 3.88
(KJ/cycle)

Cycle 27 GMT 21/ 1/2020 19:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 28 15.22 451 192 0.19 / 104.74 2 2
2 10 1014.44 3 15.17 1862 85 0.28 / 104.82 2 2
3 3 976.20 -1 15.51 0 0 0.08 / 104.82 2 2
4 3 983.04 -1 15.53 0 0 0.08 / 104.82 2 2
5 7 2004.72 30 14.97 3096 1390 1.67 / 106.21 2 2
6 13 1570.92 20 14.98 2549 764 2.43 / 106.98 2 3
7 13 968.80 20 15.07 1747 527 2.96 / 107.50 2 4
8 13 366.76 20 15.20 889 270 3.23 / 107.78 2 5
9 13 96.76 20 15.27 438 134 3.36 / 107.91 2 2
10 8 -0.12 165 15.25 310 780 4.14 / 108.69 2 2
Average= 3.88
(KJ/cycle)

Cycle 26 GMT 11/ 1/2020 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.28 27 15.22 486 200 0.20 / 100.58 2 2
2 10 1012.40 2 15.17 1847 56 0.26 / 100.64 2 2
3 7 2003.36 30 14.98 3090 1389 1.64 / 102.03 2 2
4 13 1465.96 20 15.00 2408 722 2.37 / 102.75 2 3
5 13 901.16 20 15.08 1649 497 2.86 / 103.25 2 4
6 13 341.84 20 15.20 847 257 3.12 / 103.50 2 5
7 13 41.24 20 15.28 374 114 3.24 / 103.62 2 2
8 8 0.16 165 15.25 313 788 4.02 / 104.40 2 2
9 14 0.16 30 15.23 312 143 4.17 / 104.55 2 2
Average= 3.87
(KJ/cycle)

Cycle 25 GMT 1/ 1/2020 23:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 31 15.22 490 231 0.23 / 96.50 2 2
2 3 933.52 -2 15.52 0 0 0.00 / 96.50 2 2
3 3 947.88 -2 15.54 0 0 0.00 / 96.50 2 2
4 7 2003.68 30 14.98 3094 1390 1.62 / 97.89 2 2
5 13 1588.68 20 14.99 2571 771 2.39 / 98.66 2 3
6 13 986.68 20 15.07 1767 533 2.92 / 99.19 2 4
7 13 394.24 20 15.20 929 282 3.21 / 99.48 2 5
8 13 58.52 20 15.28 396 121 3.33 / 99.60 2 2
9 8 0.00 165 15.26 311 783 4.11 / 100.38 2 3
Average= 3.86
(KJ/cycle)

Cycle 24 GMT 23/12/2019 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 30 15.22 466 213 0.21 / 92.38 2 2
2 3 1022.60 1 15.24 1911 29 0.24 / 92.40 2 3
3 7 2005.72 30 14.99 3099 1394 1.64 / 93.80 2 2
4 13 1590.88 20 14.99 2577 773 2.41 / 94.57 2 3
5 13 885.16 20 15.10 1626 491 2.90 / 95.06 2 4
6 13 449.28 20 15.18 1009 306 3.21 / 95.37 2 5
7 13 64.56 20 15.28 396 121 3.33 / 95.49 2 2
8 8 0.20 165 15.26 310 781 4.11 / 96.27 2 2
Average= 3.85
(KJ/cycle)

Cycle 23 GMT 13/12/2019 3: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 29 15.23 449 198 0.20 / 88.37 2 2
2 3 1042.80 1 15.22 1931 29 0.23 / 88.40 2 3
3 7 2006.12 30 14.98 3102 1394 1.62 / 89.80 2 2
4 13 1462.28 20 15.01 2400 720 2.34 / 90.52 2 3
5 13 894.16 20 15.10 1636 494 2.84 / 91.01 2 4
6 13 325.40 20 15.21 827 252 3.09 / 91.26 2 5
7 13 42.56 20 15.29 370 113 3.20 / 91.37 2 2
8 8 0.16 165 15.26 313 788 3.99 / 92.16 2 2
Average= 3.84
(KJ/cycle)

Cycle 22 GMT 3/12/2019 4:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 29 15.24 458 202 0.20 / 84.41 2 2
2 7 2004.68 30 15.00 3102 1396 1.60 / 85.80 2 2
3 13 1464.12 20 15.02 2408 723 2.32 / 86.53 2 3
4 13 888.00 20 15.10 1622 490 2.81 / 87.02 2 4
5 13 312.24 20 15.22 813 247 3.06 / 87.26 2 5
6 13 75.12 20 15.28 413 126 3.19 / 87.39 2 2
7 8 -0.16 165 15.26 311 783 3.97 / 88.17 2 3
Average= 3.83
(KJ/cycle)

Cycle 21 GMT 23/11/2019 6:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 29 15.24 464 205 0.21 / 80.33 2 2
2 7 2004.08 30 15.00 3093 1392 1.60 / 81.72 2 2
3 13 1596.16 20 15.00 2572 772 2.37 / 82.49 2 3
4 13 991.16 20 15.08 1767 533 2.90 / 83.03 2 4
5 13 393.88 20 15.21 925 281 3.18 / 83.31 2 4
6 13 58.24 20 15.29 391 120 3.30 / 83.43 2 2
7 8 0.20 165 15.28 308 777 4.08 / 84.21 2 2
Average= 3.83
(KJ/cycle)

Cycle 20 GMT 13/11/2019 8:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 29 15.24 452 200 0.20 / 76.31 2 2
2 7 2001.56 30 14.99 3090 1390 1.59 / 77.70 2 2
3 13 1564.12 20 15.00 2535 760 2.35 / 78.46 2 3
4 13 848.20 20 15.12 1572 475 2.83 / 78.94 2 4
5 13 413.68 20 15.20 958 291 3.12 / 79.23 2 5
6 13 58.88 20 15.29 386 118 3.23 / 79.35 2 2
7 8 -0.04 165 15.27 310 781 4.02 / 80.13 2 2
Average= 3.82
(KJ/cycle)

Cycle 19 GMT 3/11/2019 10: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 29 15.25 449 199 0.20 / 72.28 2 2
2 3 1021.88 1 15.26 1911 29 0.23 / 72.31 2 3
3 7 2005.44 30 15.01 3097 1395 1.62 / 73.70 2 2
4 13 1592.52 20 15.01 2580 775 2.40 / 74.47 2 3
5 13 892.12 20 15.11 1633 493 2.89 / 74.97 2 4
6 13 334.28 20 15.23 838 255 3.15 / 75.22 2 5
7 13 48.84 20 15.30 378 116 3.26 / 75.34 2 2
8 8 0.04 165 15.28 306 771 4.03 / 76.11 2 2
Average= 3.81
(KJ/cycle)

Cycle 18 GMT 24/10/2019 11:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 28 15.24 462 197 0.20 / 68.21 2 2
2 3 1018.24 1 15.26 1908 29 0.23 / 68.24 2 3
3 7 2002.92 30 15.00 3083 1387 1.61 / 69.63 2 2
4 13 1564.12 20 15.02 2530 760 2.37 / 70.39 2 3
5 13 963.12 20 15.10 1734 524 2.90 / 70.91 2 4
6 13 375.16 20 15.22 894 272 3.17 / 71.18 2 5
7 13 48.56 20 15.31 377 115 3.28 / 71.30 2 2
8 8 0.20 165 15.28 310 782 4.07 / 72.08 2 2
Average= 3.79
(KJ/cycle)

Cycle 17 GMT 14/10/2019 13:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 28 15.26 454 194 0.19 / 63.97 2 2
2 10 1003.84 2 15.21 1855 56 0.25 / 64.03 2 2
3 3 954.08 -1 15.55 0 0 0.06 / 64.03 2 2
4 3 979.20 -1 15.57 0 0 0.06 / 64.03 2 2
5 7 2003.44 30 15.01 3103 1397 1.65 / 65.42 2 2
6 13 1585.72 20 15.02 2574 773 2.42 / 66.20 2 3
7 13 988.68 20 15.09 1766 533 2.95 / 66.73 2 4
8 13 392.60 20 15.22 926 282 3.24 / 67.01 2 5
9 13 51.60 20 15.31 385 118 3.35 / 67.13 2 2
10 13 16.16 20 15.31 331 101 3.46 / 67.23 2 2
11 8 -0.08 165 15.28 310 782 4.24 / 68.01 2 2
Average= 3.78
(KJ/cycle)

Cycle 16 GMT 4/10/2019 15:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 28 15.25 462 197 0.20 / 59.99 2 2
2 10 1002.88 2 15.20 1834 56 0.25 / 60.05 2 2
3 3 948.64 -2 15.55 0 0 0.06 / 60.05 2 2
4 7 2001.88 30 15.01 3089 1391 1.64 / 61.44 2 2
5 13 1441.08 20 15.05 2377 715 2.36 / 62.16 2 3
6 13 877.96 20 15.12 1607 486 2.85 / 62.64 2 4
7 13 313.20 20 15.24 807 246 3.09 / 62.89 2 5
8 13 44.12 20 15.31 375 115 3.21 / 63.00 2 2
9 8 -0.12 165 15.29 306 772 3.98 / 63.78 2 2
Average= 3.75
(KJ/cycle)

Cycle 15 GMT 24/ 9/2019 16:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 28 15.26 467 200 0.20 / 55.85 2 2
2 7 2002.32 30 15.01 3090 1391 1.59 / 57.24 2 2
3 13 1571.76 20 15.03 2549 766 2.36 / 58.00 2 3
4 13 962.08 20 15.11 1729 523 2.88 / 58.53 2 4
5 13 355.16 20 15.23 873 266 3.15 / 58.79 2 5
6 13 44.80 20 15.31 383 117 3.26 / 58.91 2 2
7 13 14.84 20 15.31 332 102 3.36 / 59.01 2 2
8 8 0.12 165 15.28 312 787 4.15 / 59.80 2 2
Average= 3.74
(KJ/cycle)

Cycle 14 GMT 14/ 9/2019 18:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 28 15.26 461 197 0.20 / 51.83 2 2
2 7 2004.12 30 15.01 3094 1393 1.59 / 53.22 2 2
3 13 1580.68 18 15.04 2563 694 2.28 / 53.92 2 3
4 13 985.08 18 15.11 1771 482 2.77 / 54.40 2 4
5 13 419.36 18 15.22 965 264 3.03 / 54.66 2 5
6 13 67.00 18 15.32 401 111 3.14 / 54.78 2 2
7 13 24.52 18 15.32 339 93 3.23 / 54.87 2 2
8 8 0.16 165 15.29 308 777 4.01 / 55.65 2 2
Average= 3.71
(KJ/cycle)

Cycle 13 GMT 4/ 9/2019 20:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 28 15.26 454 194 0.19 / 47.86 2 2
2 7 2001.64 30 15.02 3086 1391 1.58 / 49.25 2 2
3 13 1559.44 18 15.04 2529 685 2.27 / 49.94 2 3
4 13 959.64 18 15.12 1729 471 2.74 / 50.41 2 4
5 13 388.96 18 15.24 923 253 2.99 / 50.66 2 4
6 13 65.52 18 15.32 400 110 3.10 / 50.77 2 2
7 13 24.84 18 15.32 336 93 3.20 / 50.86 2 2
8 8 0.08 165 15.30 305 770 3.97 / 51.63 2 3
Average= 3.69
(KJ/cycle)

Cycle 12 GMT 25/ 8/2019 22:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 28 15.27 458 196 0.20 / 43.77 2 2
2 7 2003.32 30 15.02 3085 1390 1.59 / 45.16 2 2
3 13 1584.96 18 15.04 2567 695 2.28 / 45.85 2 2
4 13 992.12 18 15.12 1781 485 2.77 / 46.34 2 3
5 13 427.28 18 15.23 977 268 3.03 / 46.61 2 4
6 13 73.48 18 15.32 409 113 3.15 / 46.72 2 2
7 13 23.96 18 15.32 336 93 3.24 / 46.81 2 2
8 13 15.08 18 15.32 327 90 3.33 / 46.90 2 2
9 8 0.12 165 15.29 304 767 4.10 / 47.67 2 3
Average= 3.67
(KJ/cycle)

Cycle 11 GMT 15/ 8/2019 23:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 28 15.27 455 195 0.19 / 39.81 2 2
2 7 2004.12 30 15.02 3098 1396 1.59 / 41.21 2 2
3 13 1447.92 18 15.06 2386 647 2.24 / 41.85 2 3
4 13 889.88 18 15.14 1634 445 2.68 / 42.30 2 3
5 13 473.96 18 15.21 1044 286 2.97 / 42.58 2 4
6 13 86.12 18 15.31 426 117 3.09 / 42.70 2 2
7 13 27.68 18 15.32 340 94 3.18 / 42.80 2 2
8 8 0.20 165 15.30 308 778 3.96 / 43.57 2 2
Average= 3.63
(KJ/cycle)

Cycle 10 GMT 6/ 8/2019 1:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 28 15.26 460 197 0.20 / 35.84 2 2
2 3 984.48 -1 15.58 0 0 0.00 / 35.84 2 2
3 7 2003.64 30 15.02 3085 1390 1.59 / 37.23 2 2
4 13 1452.80 18 15.07 2395 650 2.24 / 37.88 2 3
5 13 1006.56 18 15.12 1798 489 2.73 / 38.37 2 4
6 13 426.96 18 15.23 976 268 2.99 / 38.64 2 4
7 13 69.32 18 15.32 407 112 3.11 / 38.75 2 2
8 13 21.44 18 15.33 337 93 3.20 / 38.84 2 2
9 8 0.16 165 15.30 307 775 3.97 / 39.62 2 2
Average= 3.60
(KJ/cycle)

Cycle 9 GMT 27/ 7/2019 3: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 28 15.27 457 195 0.20 / 31.78 2 2
2 3 1022.16 1 15.29 1912 29 0.22 / 31.81 2 3
3 7 2003.16 30 15.04 3092 1395 1.62 / 33.20 2 2
4 13 1583.04 18 15.06 2568 696 2.32 / 33.90 2 3
5 13 1003.80 18 15.12 1793 488 2.80 / 34.39 2 4
6 13 421.12 18 15.23 972 266 3.07 / 34.65 2 4
7 13 74.12 18 15.32 408 113 3.18 / 34.77 2 2
8 13 21.56 18 15.33 335 92 3.28 / 34.86 2 2
9 8 0.08 165 15.30 310 783 4.06 / 35.64 2 2
Average= 3.56
(KJ/cycle)

Cycle 8 GMT 17/ 7/2019 4:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 28 15.27 463 198 0.20 / 27.79 2 2
2 7 2002.88 30 15.04 3090 1394 1.59 / 29.18 2 2
3 13 1463.96 18 15.08 2416 656 2.25 / 29.84 2 3
4 13 921.64 18 15.14 1682 458 2.71 / 30.30 2 4
5 13 485.04 18 15.22 1059 290 3.00 / 30.59 2 4
6 13 87.36 18 15.32 426 117 3.11 / 30.70 2 2
7 13 22.52 18 15.33 338 93 3.21 / 30.80 2 2
8 8 0.04 165 15.30 312 788 3.99 / 31.58 2 2
Average= 3.51
(KJ/cycle)

Cycle 7 GMT 7/ 7/2019 5:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 28 15.26 458 196 0.20 / 23.82 2 2
2 3 1018.84 1 15.30 1910 29 0.22 / 23.85 2 2
3 7 2001.88 30 15.05 3080 1391 1.62 / 25.24 2 2
4 13 1583.68 18 15.06 2562 695 2.31 / 25.93 2 3
5 13 991.84 18 15.13 1779 484 2.79 / 26.42 2 4
6 13 440.68 18 15.23 992 272 3.07 / 26.69 2 4
7 13 80.36 18 15.33 418 115 3.18 / 26.81 2 2
8 8 0.08 165 15.31 310 783 3.96 / 27.59 2 2
Average= 3.45
(KJ/cycle)

Cycle 6 GMT 27/ 6/2019 7:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 26 15.27 467 185 0.19 / 19.70 2 2
2 10 1002.36 3 15.22 1826 83 0.27 / 19.78 2 2
3 7 2003.36 31 15.04 3084 1438 1.71 / 21.22 2 2
4 13 1558.92 18 15.07 2526 685 2.39 / 21.91 2 3
5 13 967.24 18 15.14 1740 474 2.87 / 22.38 2 4
6 13 399.68 18 15.24 940 258 3.12 / 22.64 2 4
7 13 64.96 18 15.33 401 111 3.23 / 22.75 2 2
8 13 18.48 18 15.33 334 92 3.33 / 22.84 2 2
9 8 0.08 165 15.30 310 783 4.11 / 23.62 2 2
Average= 3.37
(KJ/cycle)

Cycle 5 GMT 17/ 6/2019 8:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 30 15.27 465 213 0.21 / 15.66 2 2
2 3 903.36 -2 15.56 0 0 0.00 / 15.66 2 2
3 3 962.24 -1 15.58 0 0 0.00 / 15.66 2 2
4 7 2002.12 40 14.99 3071 1841 2.05 / 17.50 2 2
5 13 1212.96 18 15.11 2072 564 2.62 / 18.07 2 3
6 13 763.52 18 15.17 1459 398 3.02 / 18.47 2 4
7 13 173.36 18 15.30 600 165 3.18 / 18.63 2 4
8 13 15.60 18 15.34 336 93 3.27 / 18.72 2 2
9 8 0.00 165 15.30 313 790 4.06 / 19.51 2 2
Average= 3.25
(KJ/cycle)

Cycle 4 GMT 7/ 6/2019 10:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 28 15.27 452 193 0.19 / 12.22 2 2
2 7 1510.12 40 15.11 2440 1475 1.67 / 13.70 2 2
3 13 1091.36 18 15.15 1902 519 2.19 / 14.22 2 3
4 13 523.96 18 15.24 1114 306 2.49 / 14.52 2 4
5 13 121.80 18 15.32 494 136 2.63 / 14.66 2 3
6 8 0.16 165 15.31 313 791 3.42 / 15.45 2 2
Average= 3.09
(KJ/cycle)

Cycle 3 GMT 6/ 6/2019 10:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 28 15.27 468 200 0.20 / 8.78 2 2
2 7 1521.76 41 15.10 2447 1515 1.72 / 10.29 2 2
3 13 1094.84 18 15.15 1911 521 2.24 / 10.81 2 3
4 13 512.80 18 15.23 1095 300 2.54 / 11.11 2 4
5 13 115.56 18 15.32 479 132 2.67 / 11.25 2 2
6 8 0.08 165 15.31 311 786 3.45 / 12.03 2 2
Average= 3.01
(KJ/cycle)

Cycle 2 GMT 5/ 6/2019 10:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 24 15.31 465 171 0.17 / 4.74 2 2
2 10 1004.72 4 15.22 1850 113 0.28 / 4.86 2 2
3 3 1026.64 1 15.30 1915 29 0.31 / 4.89 2 2
4 7 1520.28 74 15.02 2439 2711 3.02 / 7.60 2 3
5 13 230.68 18 15.29 688 189 3.21 / 7.79 2 4
6 8 0.12 165 15.31 313 791 4.00 / 8.58 2 2
Average= 2.86
(KJ/cycle)

Cycle 1 GMT 4/ 6/2019 10:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 23 15.48 447 159 0.16 / 1.73 2 3
2 3 1067.28 2 15.29 1959 60 0.22 / 1.79 2 2
3 7 999.28 75 15.16 1744 1983 2.20 / 3.77 2 4
4 8 0.12 165 15.35 317 803 3.00 / 4.57 2 2
Average= 2.29
(KJ/cycle)

Cycle 0 GMT 4/ 6/2019 0:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 88.16 22 15.62 403 138 0.14 / 0.14 2 3
2 7 103.40 74 15.59 418 482 0.62 / 0.62 2 3
3 8 0.20 240 15.55 254 948 1.57 / 1.57 2 4
Average= 1.57
(KJ/cycle)