SIO Argo Site:
Pump Diagnostics Page   



Serial= 8762 WMO= 4903014

Return

←PreviousNext→

Cycle 214 GMT 10/12/2024 13:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 31 14.85 493 227 0.23 / 891.86 2 3
2 7 2007.72 34 14.64 2990 1488 1.72 / 893.35 2 3
3 13 1583.28 20 14.66 2464 722 2.44 / 894.07 2 5
4 13 1008.60 20 14.69 1755 516 2.95 / 894.59 2 4
5 13 431.52 20 14.81 978 290 3.24 / 894.88 2 5
6 13 71.32 20 14.91 470 140 3.38 / 895.02 2 3
7 8 0.24 165 14.89 348 855 4.24 / 895.87 2 7
Average= 4.17
(KJ/cycle)

Cycle 213 GMT 30/11/2024 15:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 31 14.86 493 227 0.23 / 887.66 2 3
2 7 2003.72 33 14.66 2975 1439 1.67 / 889.10 2 3
3 13 1591.56 20 14.66 2483 728 2.39 / 889.83 2 4
4 13 1013.16 20 14.70 1749 514 2.91 / 890.34 2 4
5 13 450.52 20 14.80 1019 302 3.21 / 890.64 2 5
6 13 82.56 20 14.90 475 142 3.35 / 890.78 2 3
7 8 0.00 165 14.89 346 850 4.20 / 891.63 2 8
Average= 4.17
(KJ/cycle)

Cycle 212 GMT 20/11/2024 17:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 31 14.86 483 222 0.22 / 883.41 2 3
2 7 2010.12 33 14.65 2988 1445 1.67 / 884.85 2 3
3 13 1602.72 20 14.66 2505 734 2.40 / 885.59 2 3
4 13 1027.68 20 14.70 1777 522 2.92 / 886.11 2 4
5 13 456.60 20 14.80 1013 300 3.22 / 886.41 2 3
6 13 86.48 20 14.90 501 149 3.37 / 886.56 2 3
7 8 -0.08 165 14.89 356 875 4.25 / 887.43 2 10
Average= 4.17
(KJ/cycle)

Cycle 211 GMT 10/11/2024 19:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 31 14.86 484 223 0.22 / 879.18 2 3
2 7 2009.44 34 14.65 2981 1485 1.71 / 880.66 2 5
3 13 1597.36 20 14.65 2515 737 2.44 / 881.40 2 5
4 13 1016.12 20 14.70 1755 516 2.96 / 881.91 2 4
5 13 433.72 20 14.81 984 291 3.25 / 882.20 2 5
6 13 71.12 20 14.91 462 138 3.39 / 882.34 2 3
7 8 0.00 165 14.89 343 843 4.23 / 883.19 2 9
Average= 4.17
(KJ/cycle)

Cycle 210 GMT 31/10/2024 21:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 31 14.87 493 227 0.23 / 875.00 2 3
2 7 2003.72 33 14.65 2971 1436 1.66 / 876.44 2 4
3 13 1585.68 20 14.66 2495 732 2.40 / 877.17 2 4
4 13 993.12 20 14.71 1730 509 2.90 / 877.68 2 4
5 13 427.44 20 14.81 971 288 3.19 / 877.97 2 6
6 13 74.84 20 14.91 466 139 3.33 / 878.11 2 3
7 8 0.16 165 14.89 344 845 4.18 / 878.95 2 9
Average= 4.17
(KJ/cycle)

Cycle 209 GMT 21/10/2024 23:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 31 14.86 484 223 0.22 / 870.80 2 3
2 7 2010.52 34 14.65 2973 1481 1.70 / 872.28 2 3
3 13 1591.16 20 14.65 2495 731 2.43 / 873.01 2 5
4 13 996.28 20 14.70 1738 511 2.95 / 873.52 2 5
5 13 421.20 20 14.81 963 285 3.23 / 873.81 2 4
6 13 68.80 20 14.91 448 134 3.36 / 873.94 2 3
7 8 0.04 165 14.90 339 833 4.20 / 874.78 2 8
Average= 4.17
(KJ/cycle)

Cycle 208 GMT 12/10/2024 2: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 31 14.86 520 240 0.24 / 866.62 2 3
2 7 2008.68 33 14.65 2985 1443 1.68 / 868.06 2 4
3 13 1590.44 20 14.66 2491 730 2.41 / 868.79 2 4
4 13 1020.08 20 14.70 1766 519 2.93 / 869.31 2 5
5 13 450.96 20 14.80 1014 300 3.23 / 869.61 2 5
6 13 82.64 20 14.91 471 140 3.37 / 869.75 2 3
7 8 -0.04 165 14.89 337 828 4.20 / 870.58 2 8
Average= 4.17
(KJ/cycle)

Cycle 207 GMT 2/10/2024 4:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 31 14.86 493 227 0.23 / 862.41 2 3
2 7 2004.68 33 14.65 2982 1442 1.67 / 863.85 2 3
3 13 1593.52 20 14.66 2495 732 2.40 / 864.58 2 4
4 13 1002.60 20 14.71 1749 515 2.91 / 865.10 2 4
5 13 429.80 20 14.81 988 293 3.21 / 865.39 2 4
6 13 77.64 20 14.91 477 142 3.35 / 865.53 2 3
7 8 0.12 165 14.89 345 848 4.20 / 866.38 2 8
Average= 4.17
(KJ/cycle)

Cycle 206 GMT 22/ 9/2024 6:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.04 31 14.86 503 232 0.23 / 858.23 2 3
2 7 2009.16 33 14.66 2988 1446 1.68 / 859.68 2 3
3 13 1580.04 20 14.66 2475 726 2.40 / 860.41 2 4
4 13 998.12 20 14.72 1726 508 2.91 / 860.91 2 5
5 13 434.12 20 14.81 981 291 3.20 / 861.20 2 3
6 13 71.64 20 14.91 456 136 3.34 / 861.34 2 3
7 8 0.04 165 14.89 342 840 4.18 / 862.18 2 10
Average= 4.17
(KJ/cycle)

Cycle 205 GMT 12/ 9/2024 8:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 31 14.86 482 222 0.22 / 854.03 2 3
2 7 2008.96 33 14.65 2977 1439 1.66 / 855.47 2 5
3 13 1592.16 20 14.65 2507 735 2.40 / 856.21 2 5
4 13 997.92 20 14.71 1753 516 2.91 / 856.72 2 5
5 13 433.80 20 14.81 991 294 3.21 / 857.01 2 4
6 13 72.88 20 14.91 480 143 3.35 / 857.16 2 3
7 8 0.08 165 14.89 344 845 4.19 / 858.00 2 11
Average= 4.17
(KJ/cycle)

Cycle 204 GMT 2/ 9/2024 10:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 31 14.86 499 230 0.23 / 849.89 2 3
2 7 2005.36 33 14.66 2973 1438 1.67 / 851.33 2 3
3 13 1579.12 20 14.67 2460 722 2.39 / 852.05 2 4
4 13 885.08 20 14.73 1603 472 2.86 / 852.52 2 5
5 13 461.92 20 14.80 1024 303 3.17 / 852.82 2 4
6 13 87.64 20 14.90 496 148 3.31 / 852.97 2 3
7 8 0.04 165 14.89 341 838 4.15 / 853.81 2 7
Average= 4.16
(KJ/cycle)

Cycle 203 GMT 23/ 8/2024 12:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 31 14.86 504 232 0.23 / 845.72 2 3
2 7 2004.20 33 14.66 2964 1434 1.67 / 847.15 2 3
3 13 1585.28 20 14.67 2470 725 2.39 / 847.88 2 4
4 13 991.68 20 14.72 1720 506 2.90 / 848.38 2 3
5 13 431.44 20 14.82 976 289 3.19 / 848.67 2 4
6 13 75.12 20 14.92 465 139 3.33 / 848.81 2 3
7 8 0.04 165 14.90 344 846 4.17 / 849.66 2 9
Average= 4.16
(KJ/cycle)

Cycle 202 GMT 13/ 8/2024 14:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 31 14.86 477 220 0.22 / 841.57 2 3
2 7 2006.84 33 14.66 2976 1440 1.66 / 843.01 2 3
3 13 1474.00 20 14.69 2337 687 2.35 / 843.69 2 3
4 13 1038.96 20 14.71 1780 524 2.87 / 844.22 2 4
5 13 447.24 20 14.81 1008 299 3.17 / 844.52 2 5
6 13 79.96 20 14.92 466 139 3.31 / 844.65 2 3
7 8 0.08 165 14.90 339 833 4.14 / 845.49 2 8
Average= 4.16
(KJ/cycle)

Cycle 201 GMT 3/ 8/2024 16:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 31 14.87 501 231 0.23 / 837.42 2 3
2 7 2003.00 33 14.67 2958 1432 1.66 / 838.85 2 3
3 13 1577.52 20 14.68 2460 722 2.39 / 839.57 2 5
4 13 1001.48 20 14.72 1742 513 2.90 / 840.09 2 4
5 13 431.72 20 14.82 984 292 3.19 / 840.38 2 4
6 13 70.08 20 14.92 454 135 3.33 / 840.51 2 3
7 8 0.00 165 14.90 339 833 4.16 / 841.35 2 8
Average= 4.17
(KJ/cycle)

Cycle 200 GMT 24/ 7/2024 18:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 31 14.86 494 228 0.23 / 833.23 2 3
2 7 2007.12 33 14.66 2972 1438 1.67 / 834.67 2 4
3 13 1598.24 20 14.66 2510 736 2.40 / 835.41 2 4
4 13 1010.12 20 14.72 1748 515 2.92 / 835.92 2 5
5 13 443.20 20 14.82 993 294 3.21 / 836.22 2 4
6 13 77.56 20 14.92 463 138 3.35 / 836.35 2 3
7 8 0.12 165 14.90 339 833 4.18 / 837.19 2 14
Average= 4.17
(KJ/cycle)

Cycle 199 GMT 14/ 7/2024 20:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 31 14.86 494 228 0.23 / 829.07 2 3
2 7 2004.56 33 14.67 2954 1430 1.66 / 830.50 2 3
3 13 1595.76 20 14.66 2491 730 2.39 / 831.23 2 4
4 13 1027.88 20 14.71 1767 520 2.91 / 831.75 2 5
5 13 441.48 20 14.82 989 293 3.20 / 832.04 2 4
6 13 75.80 20 14.92 459 137 3.34 / 832.18 2 3
7 8 0.12 165 14.90 338 831 4.17 / 833.01 2 9
Average= 4.17
(KJ/cycle)

Cycle 198 GMT 4/ 7/2024 22:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 31 14.86 498 229 0.23 / 824.89 2 3
2 7 2003.84 33 14.66 2962 1433 1.66 / 826.33 2 4
3 13 1605.76 20 14.67 2500 733 2.40 / 827.06 2 4
4 13 904.80 20 14.74 1607 474 2.87 / 827.53 2 4
5 13 483.96 20 14.80 1047 310 3.18 / 827.84 2 4
6 13 89.20 20 14.91 486 145 3.32 / 827.99 2 3
7 8 -0.04 165 14.90 345 848 4.17 / 828.84 2 8
Average= 4.17
(KJ/cycle)

Cycle 197 GMT 25/ 6/2024 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 31 14.87 503 232 0.23 / 820.71 2 3
2 7 2007.84 33 14.67 2983 1444 1.68 / 822.15 2 4
3 13 1595.68 20 14.67 2499 733 2.41 / 822.88 2 5
4 13 1015.68 20 14.72 1750 515 2.92 / 823.40 2 4
5 13 441.48 20 14.82 984 292 3.22 / 823.69 2 4
6 13 75.40 20 14.92 465 139 3.35 / 823.83 2 3
7 8 0.00 165 14.90 340 836 4.19 / 824.67 2 6
Average= 4.16
(KJ/cycle)

Cycle 196 GMT 15/ 6/2024 3: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 31 14.86 489 225 0.23 / 816.53 2 3
2 7 2003.68 33 14.66 2965 1434 1.66 / 817.97 2 3
3 13 1578.16 20 14.67 2464 723 2.38 / 818.69 2 6
4 13 981.68 20 14.72 1717 505 2.89 / 819.20 2 5
5 13 416.56 20 14.83 954 283 3.17 / 819.48 2 5
6 13 67.00 20 14.92 467 139 3.31 / 819.62 2 3
7 8 0.00 165 14.90 348 856 4.17 / 820.47 2 9
Average= 4.16
(KJ/cycle)

Cycle 195 GMT 5/ 6/2024 5:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 31 14.86 470 217 0.22 / 812.28 2 3
2 7 2005.96 33 14.67 2985 1445 1.66 / 813.73 2 3
3 13 1592.88 20 14.67 2498 733 2.39 / 814.46 2 3
4 13 999.20 20 14.72 1731 510 2.90 / 814.97 2 6
5 13 543.12 20 14.79 1131 335 3.24 / 815.30 2 6
6 13 112.88 20 14.90 530 158 3.40 / 815.46 2 3
7 8 0.08 165 14.90 344 846 4.24 / 816.31 2 11
Average= 4.16
(KJ/cycle)

Cycle 194 GMT 26/ 5/2024 7:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 31 14.87 519 239 0.24 / 808.09 2 2
2 7 2005.88 33 14.66 2979 1441 1.68 / 809.53 2 3
3 13 1590.44 20 14.67 2477 727 2.41 / 810.26 2 5
4 13 1014.84 20 14.72 1763 519 2.93 / 810.78 2 4
5 13 443.68 20 14.81 992 294 3.22 / 811.07 2 5
6 13 78.36 20 14.92 486 145 3.37 / 811.22 2 3
7 8 0.08 165 14.90 346 851 4.22 / 812.07 2 9
Average= 4.16
(KJ/cycle)

Cycle 193 GMT 16/ 5/2024 9:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 31 14.87 496 229 0.23 / 803.81 2 3
2 7 2007.44 33 14.67 2984 1445 1.67 / 805.25 2 3
3 13 1606.32 20 14.67 2512 737 2.41 / 805.99 2 3
4 13 1161.44 20 14.68 1941 570 2.98 / 806.56 2 4
5 13 418.36 20 14.83 959 284 3.26 / 806.85 2 5
6 13 67.80 20 14.92 459 137 3.40 / 806.98 2 3
7 8 0.04 165 14.90 353 868 4.27 / 807.85 2 9
Average= 4.16
(KJ/cycle)

Cycle 192 GMT 6/ 5/2024 11:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 31 14.86 523 241 0.24 / 799.73 2 3
2 7 2005.96 33 14.67 2969 1437 1.68 / 801.17 2 3
3 13 1475.88 20 14.69 2333 685 2.36 / 801.86 2 3
4 13 927.20 20 14.73 1643 484 2.85 / 802.34 2 4
5 13 384.52 20 14.83 928 275 3.12 / 802.62 2 4
6 13 55.76 20 14.93 430 128 3.25 / 802.75 2 3
7 8 0.04 165 14.90 340 836 4.09 / 803.58 2 10
Average= 4.16
(KJ/cycle)

Cycle 191 GMT 26/ 4/2024 13:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 31 14.86 522 240 0.24 / 795.59 2 3
2 7 2010.24 33 14.66 2983 1443 1.68 / 797.03 2 3
3 13 1469.52 20 14.69 2345 689 2.37 / 797.72 2 5
4 13 929.00 20 14.73 1644 484 2.86 / 798.21 2 5
5 13 384.08 20 14.83 918 272 3.13 / 798.48 2 5
6 13 113.36 20 14.90 530 158 3.29 / 798.64 2 3
7 8 0.12 165 14.90 349 858 4.15 / 799.49 2 8
Average= 4.16
(KJ/cycle)

Cycle 190 GMT 16/ 4/2024 15:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 31 14.87 491 226 0.23 / 791.41 2 2
2 7 2002.80 33 14.68 2973 1440 1.67 / 792.85 2 3
3 13 1578.32 20 14.68 2451 720 2.39 / 793.57 2 5
4 13 984.24 20 14.73 1722 507 2.89 / 794.07 2 4
5 13 418.52 20 14.83 975 289 3.18 / 794.36 2 4
6 13 69.20 20 14.92 456 136 3.32 / 794.50 2 3
7 8 -0.12 165 14.90 346 851 4.17 / 795.35 2 10
Average= 4.16
(KJ/cycle)

Cycle 189 GMT 6/ 4/2024 17:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 31 14.86 507 234 0.23 / 787.29 2 3
2 7 2002.72 33 14.67 2967 1436 1.67 / 788.73 2 5
3 13 1462.08 20 14.70 2333 686 2.36 / 789.42 2 4
4 13 902.08 20 14.75 1605 473 2.83 / 789.89 2 4
5 13 471.48 20 14.81 1037 307 3.14 / 790.20 2 5
6 13 45.52 20 14.93 431 129 3.27 / 790.33 2 3
7 8 0.16 165 14.90 347 853 4.12 / 791.18 2 13
Average= 4.16
(KJ/cycle)

Cycle 188 GMT 27/ 3/2024 19:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.80 31 14.87 513 236 0.24 / 783.02 2 3
2 7 2003.00 33 14.68 2987 1447 1.68 / 784.46 2 3
3 13 1600.44 20 14.67 2514 738 2.42 / 785.20 2 3
4 13 1012.28 20 14.72 1768 520 2.94 / 785.72 2 4
5 13 553.52 20 14.79 1145 339 3.28 / 786.06 2 4
6 13 114.88 20 14.91 518 154 3.43 / 786.22 2 3
7 8 0.24 165 14.90 344 846 4.28 / 787.06 2 10
Average= 4.16
(KJ/cycle)

Cycle 187 GMT 17/ 3/2024 22: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.20 31 14.86 508 234 0.23 / 778.80 2 3
2 7 2006.44 33 14.68 2974 1441 1.67 / 780.24 2 3
3 13 1584.64 20 14.69 2474 727 2.40 / 780.97 2 3
4 13 1001.48 20 14.73 1752 516 2.92 / 781.48 2 4
5 13 428.20 20 14.83 972 288 3.21 / 781.77 2 5
6 13 135.20 20 14.91 545 163 3.37 / 781.93 2 3
7 8 0.00 165 14.90 344 846 4.21 / 782.78 2 10
Average= 4.16
(KJ/cycle)

Cycle 186 GMT 8/ 3/2024 0:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 31 14.86 511 235 0.24 / 774.59 2 3
2 7 2004.80 33 14.67 2973 1439 1.67 / 776.02 2 4
3 13 1592.12 20 14.68 2480 728 2.40 / 776.75 2 4
4 13 1019.92 20 14.72 1771 521 2.92 / 777.27 2 3
5 13 442.64 20 14.83 997 296 3.22 / 777.57 2 6
6 13 76.20 20 14.92 471 141 3.36 / 777.71 2 3
7 8 0.00 165 14.90 348 856 4.22 / 778.57 2 13
Average= 4.16
(KJ/cycle)

Cycle 185 GMT 27/ 2/2024 2:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 31 14.87 508 234 0.23 / 770.34 2 3
2 7 2004.64 33 14.67 2986 1446 1.68 / 771.78 2 4
3 13 1588.96 20 14.68 2494 732 2.41 / 772.51 2 5
4 13 1008.72 20 14.72 1766 520 2.93 / 773.03 2 5
5 13 434.60 20 14.83 994 295 3.23 / 773.33 2 5
6 13 141.00 20 14.90 577 172 3.40 / 773.50 2 3
7 8 0.12 165 14.90 346 851 4.25 / 774.35 2 14
Average= 4.16
(KJ/cycle)

Cycle 184 GMT 17/ 2/2024 4:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 31 14.87 505 233 0.23 / 766.11 2 3
2 7 2003.48 34 14.66 2980 1485 1.72 / 767.59 2 4
3 13 1593.88 20 14.67 2484 729 2.45 / 768.32 2 4
4 13 993.04 20 14.73 1721 507 2.95 / 768.83 2 4
5 13 419.56 20 14.83 963 286 3.24 / 769.11 2 4
6 13 64.64 20 14.93 446 133 3.37 / 769.25 2 3
7 8 -0.20 165 14.91 347 854 4.23 / 770.10 2 7
Average= 4.16
(KJ/cycle)

Cycle 183 GMT 7/ 2/2024 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 31 14.87 480 221 0.22 / 761.86 2 3
2 7 2008.84 33 14.68 2964 1436 1.66 / 763.29 2 3
3 13 1586.36 20 14.68 2493 732 2.39 / 764.03 2 4
4 13 1005.68 20 14.73 1731 510 2.90 / 764.54 2 4
5 13 555.00 20 14.80 1142 338 3.24 / 764.87 2 5
6 13 120.72 20 14.92 528 158 3.39 / 765.03 2 3
7 8 0.16 165 14.91 343 844 4.24 / 765.87 2 8
Average= 4.16
(KJ/cycle)

Cycle 182 GMT 28/ 1/2024 8:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 31 14.87 497 229 0.23 / 757.66 2 2
2 7 2005.56 33 14.68 2966 1437 1.67 / 759.10 2 3
3 13 1584.24 20 14.69 2470 726 2.39 / 759.83 2 5
4 13 991.96 20 14.74 1721 507 2.90 / 760.33 2 4
5 13 430.04 20 14.83 968 287 3.19 / 760.62 2 4
6 13 142.00 20 14.91 563 168 3.35 / 760.79 2 3
7 8 0.12 165 14.91 345 849 4.20 / 761.64 2 9
Average= 4.16
(KJ/cycle)

Cycle 181 GMT 18/ 1/2024 10:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 31 14.88 500 231 0.23 / 753.40 2 3
2 7 2004.56 33 14.68 2973 1440 1.67 / 754.84 2 4
3 13 1587.60 20 14.69 2478 728 2.40 / 755.57 2 5
4 13 999.68 20 14.74 1733 511 2.91 / 756.08 2 4
5 13 542.00 20 14.80 1140 337 3.25 / 756.42 2 4
6 13 119.60 20 14.92 537 160 3.41 / 756.58 2 3
7 8 -0.12 165 14.91 348 856 4.26 / 757.43 2 5
Average= 4.16
(KJ/cycle)

Cycle 180 GMT 8/ 1/2024 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 31 14.87 518 239 0.24 / 749.04 2 3
2 7 2004.56 33 14.68 2985 1446 1.68 / 750.49 2 3
3 13 1732.60 20 14.66 2669 783 2.47 / 751.27 2 4
4 13 1116.88 20 14.71 1890 556 3.02 / 751.83 2 5
5 13 514.16 20 14.81 1105 327 3.35 / 752.15 2 4
6 13 115.36 20 14.92 534 159 3.51 / 752.31 2 3
7 8 0.04 165 14.91 348 856 4.37 / 753.17 2 13
Average= 4.16
(KJ/cycle)

Cycle 179 GMT 29/12/2023 15: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 31 14.87 481 222 0.22 / 744.78 2 3
2 7 2004.28 33 14.68 2974 1441 1.66 / 746.22 2 3
3 13 1597.20 20 14.68 2499 734 2.40 / 746.95 2 3
4 13 1010.72 20 14.73 1755 517 2.91 / 747.47 2 4
5 13 439.28 20 14.83 1000 297 3.21 / 747.76 2 4
6 13 153.80 20 14.90 599 179 3.39 / 747.94 2 4
7 8 0.04 165 14.91 350 861 4.25 / 748.80 2 7
Average= 4.16
(KJ/cycle)

Cycle 178 GMT 19/12/2023 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 31 14.87 479 221 0.22 / 740.57 2 3
2 7 2002.76 33 14.68 2997 1452 1.67 / 742.03 2 4
3 13 1591.84 20 14.68 2507 736 2.41 / 742.76 2 3
4 13 1002.24 20 14.73 1743 513 2.92 / 743.27 2 6
5 13 446.96 20 14.83 1007 299 3.22 / 743.57 2 4
6 13 94.72 20 14.93 498 149 3.37 / 743.72 2 3
7 8 0.12 165 14.92 338 832 4.20 / 744.55 2 10
Average= 4.16
(KJ/cycle)

Cycle 177 GMT 9/12/2023 19: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 31 14.87 477 220 0.22 / 736.30 2 3
2 7 2002.44 33 14.68 2990 1448 1.67 / 737.75 2 3
3 13 1725.92 20 14.66 2679 785 2.45 / 738.53 2 3
4 13 979.96 20 14.74 1727 509 2.96 / 739.04 2 5
5 13 416.72 20 14.84 968 287 3.25 / 739.33 2 4
6 13 136.40 20 14.91 573 171 3.42 / 739.50 2 3
7 8 0.04 165 14.91 347 854 4.27 / 740.35 2 12
Average= 4.16
(KJ/cycle)

Cycle 176 GMT 29/11/2023 21: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 31 14.87 476 219 0.22 / 732.06 2 3
2 7 2004.08 33 14.69 2977 1443 1.66 / 733.50 2 3
3 13 1592.80 20 14.68 2479 728 2.39 / 734.23 2 3
4 13 999.48 20 14.74 1737 512 2.90 / 734.74 2 5
5 13 442.76 20 14.84 990 294 3.20 / 735.03 2 5
6 13 148.16 20 14.91 578 172 3.37 / 735.21 2 3
7 8 0.08 165 14.91 354 871 4.24 / 736.08 2 9
Average= 4.16
(KJ/cycle)

Cycle 175 GMT 19/11/2023 23:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 31 14.88 488 225 0.23 / 727.86 2 3
2 7 2003.84 33 14.67 2979 1442 1.67 / 729.30 2 4
3 13 1590.80 20 14.68 2497 733 2.40 / 730.04 2 3
4 13 1007.48 20 14.74 1748 515 2.92 / 730.55 2 5
5 13 423.48 20 14.84 961 285 3.20 / 730.84 2 3
6 13 138.08 20 14.92 553 165 3.37 / 731.00 2 4
7 8 0.16 165 14.92 339 835 4.20 / 731.84 2 8
Average= 4.16
(KJ/cycle)

Cycle 174 GMT 10/11/2023 1:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 31 14.88 481 222 0.22 / 723.63 2 3
2 7 2006.60 33 14.68 2969 1438 1.66 / 725.07 2 3
3 13 1596.72 20 14.69 2484 730 2.39 / 725.80 2 4
4 13 1008.92 20 14.74 1745 514 2.90 / 726.31 2 4
5 13 440.08 20 14.84 990 294 3.20 / 726.60 2 4
6 13 149.16 20 14.91 581 173 3.37 / 726.78 2 3
7 8 0.20 165 14.91 350 861 4.23 / 727.64 2 8
Average= 4.16
(KJ/cycle)

Cycle 173 GMT 31/10/2023 3:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 31 14.88 480 221 0.22 / 719.42 2 3
2 7 2003.88 33 14.69 2975 1442 1.66 / 720.86 2 3
3 13 1595.32 20 14.69 2492 732 2.40 / 721.59 2 3
4 13 997.96 20 14.74 1734 511 2.91 / 722.10 2 4
5 13 432.92 20 14.84 979 291 3.20 / 722.39 2 4
6 13 146.80 20 14.91 576 172 3.37 / 722.57 2 3
7 8 0.16 165 14.92 341 839 4.21 / 723.41 2 10
Average= 4.16
(KJ/cycle)

Cycle 172 GMT 21/10/2023 5:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 31 14.88 476 220 0.22 / 715.17 2 3
2 7 2003.88 33 14.68 2982 1445 1.66 / 716.62 2 4
3 13 1584.52 20 14.69 2465 724 2.39 / 717.34 2 4
4 13 996.36 20 14.74 1732 511 2.90 / 717.85 2 6
5 13 534.44 20 14.81 1123 333 3.23 / 718.18 2 4
6 13 112.52 20 14.92 525 157 3.39 / 718.34 2 3
7 8 0.04 165 14.92 348 857 4.24 / 719.20 2 8
Average= 4.16
(KJ/cycle)

Cycle 171 GMT 11/10/2023 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 31 14.89 469 216 0.22 / 711.03 2 3
2 7 2005.00 33 14.67 2984 1445 1.66 / 712.47 2 3
3 13 1596.72 20 14.69 2485 730 2.39 / 713.20 2 3
4 13 879.84 20 14.76 1583 467 2.86 / 713.67 2 4
5 13 450.40 20 14.84 997 296 3.15 / 713.97 2 4
6 13 81.40 20 14.94 477 143 3.30 / 714.11 2 3
7 8 -0.04 165 14.92 342 842 4.14 / 714.95 2 8
Average= 4.16
(KJ/cycle)

Cycle 170 GMT 1/10/2023 10: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 31 14.89 479 221 0.22 / 706.83 2 3
2 7 2003.12 33 14.69 2967 1438 1.66 / 708.27 2 3
3 13 1584.08 20 14.70 2474 727 2.39 / 709.00 2 4
4 13 1003.12 20 14.75 1742 514 2.90 / 709.51 2 6
5 13 440.12 20 14.84 991 294 3.19 / 709.80 2 4
6 13 154.44 20 14.91 578 172 3.37 / 709.98 2 3
7 8 0.04 165 14.92 340 837 4.20 / 710.81 2 8
Average= 4.16
(KJ/cycle)

Cycle 169 GMT 21/ 9/2023 12: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 31 14.88 482 222 0.22 / 702.69 2 3
2 7 2003.72 33 14.69 2970 1440 1.66 / 704.13 2 3
3 13 1479.52 20 14.71 2346 690 2.35 / 704.82 2 4
4 13 918.52 20 14.76 1629 481 2.83 / 705.30 2 5
5 13 482.84 20 14.83 1047 311 3.14 / 705.61 2 4
6 13 95.60 20 14.93 492 147 3.29 / 705.76 2 3
7 8 0.08 165 14.92 345 849 4.14 / 706.61 2 10
Average= 4.16
(KJ/cycle)

Cycle 168 GMT 11/ 9/2023 14: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.44 31 14.89 513 237 0.24 / 698.50 2 3
2 7 2003.88 34 14.68 2960 1477 1.71 / 699.98 2 3
3 13 1577.72 20 14.70 2465 725 2.44 / 700.70 2 3
4 13 877.52 20 14.77 1575 465 2.90 / 701.17 2 5
5 13 457.44 20 14.84 1013 301 3.20 / 701.47 2 4
6 13 86.20 20 14.94 489 146 3.35 / 701.62 2 3
7 8 0.04 165 14.92 346 852 4.20 / 702.47 2 6
Average= 4.16
(KJ/cycle)

Cycle 167 GMT 1/ 9/2023 16: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 31 14.89 471 217 0.22 / 694.26 2 3
2 7 2010.08 34 14.67 2976 1484 1.70 / 695.74 2 4
3 13 1589.40 20 14.69 2481 729 2.43 / 696.47 2 5
4 13 979.00 20 14.75 1711 505 2.94 / 696.97 2 4
5 13 411.36 20 14.86 950 282 3.22 / 697.26 2 4
6 13 132.72 20 14.93 551 165 3.38 / 697.42 2 3
7 8 0.08 165 14.92 343 844 4.23 / 698.27 2 13
Average= 4.16
(KJ/cycle)

Cycle 166 GMT 22/ 8/2023 18:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 30 14.89 495 221 0.22 / 690.08 2 3
2 7 2005.08 33 14.69 2974 1442 1.66 / 691.52 2 3
3 13 1594.12 20 14.69 2495 733 2.40 / 692.26 2 5
4 13 902.60 20 14.76 1607 474 2.87 / 692.73 2 5
5 13 469.68 20 14.83 1046 310 3.18 / 693.04 2 4
6 13 95.88 20 14.94 508 152 3.33 / 693.19 2 3
7 8 0.00 165 14.93 343 845 4.18 / 694.04 2 10
Average= 4.16
(KJ/cycle)

Cycle 165 GMT 12/ 8/2023 20:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 30 14.89 480 214 0.21 / 685.84 2 3
2 7 2003.40 33 14.69 2977 1443 1.66 / 687.29 2 3
3 13 1583.80 20 14.69 2491 732 2.39 / 688.02 2 4
4 13 997.48 20 14.75 1739 513 2.90 / 688.53 2 4
5 13 419.84 20 14.85 963 286 3.19 / 688.82 2 4
6 13 133.88 20 14.93 565 169 3.36 / 688.99 2 4
7 8 0.12 165 14.92 356 876 4.23 / 689.86 2 9
Average= 4.16
(KJ/cycle)

Cycle 164 GMT 2/ 8/2023 22:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 30 14.88 498 222 0.22 / 681.60 2 3
2 7 2005.44 33 14.69 2975 1442 1.66 / 683.04 2 3
3 13 1583.88 20 14.70 2498 734 2.40 / 683.77 2 3
4 13 1002.28 20 14.75 1753 517 2.92 / 684.29 2 5
5 13 424.16 20 14.85 983 292 3.21 / 684.58 2 4
6 13 131.36 20 14.92 572 171 3.38 / 684.75 2 3
7 8 0.04 165 14.92 355 874 4.25 / 685.63 2 8
Average= 4.16
(KJ/cycle)

Cycle 163 GMT 24/ 7/2023 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 30 14.88 492 220 0.22 / 677.29 2 3
2 7 2002.44 33 14.69 2973 1441 1.66 / 678.73 2 4
3 13 1593.80 20 14.69 2495 733 2.39 / 679.46 2 3
4 13 1013.12 20 14.74 1760 519 2.91 / 679.98 2 5
5 13 557.60 20 14.82 1158 343 3.26 / 680.32 2 4
6 13 122.20 20 14.93 552 165 3.42 / 680.49 2 3
7 8 0.12 165 14.92 360 886 4.31 / 681.38 2 7
Average= 4.15
(KJ/cycle)

Cycle 162 GMT 14/ 7/2023 2:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 30 14.88 489 218 0.22 / 673.00 2 3
2 7 2002.28 33 14.69 2964 1437 1.66 / 674.43 2 3
3 13 1593.36 20 14.69 2494 733 2.39 / 675.17 2 3
4 13 990.32 20 14.75 1723 508 2.90 / 675.68 2 5
5 13 535.48 20 14.83 1135 337 3.23 / 676.01 2 3
6 13 114.36 20 14.93 553 165 3.40 / 676.18 2 3
7 8 0.04 165 14.92 362 891 4.29 / 677.07 2 9
Average= 4.15
(KJ/cycle)

Cycle 161 GMT 4/ 7/2023 4:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 30 14.89 492 220 0.22 / 668.83 2 3
2 7 2005.76 33 14.69 2970 1440 1.66 / 670.27 2 3
3 13 1467.04 20 14.72 2331 686 2.35 / 670.95 2 3
4 13 927.64 20 14.76 1652 488 2.83 / 671.44 2 6
5 13 481.00 20 14.84 1061 315 3.15 / 671.76 2 4
6 13 98.48 20 14.94 517 154 3.30 / 671.91 2 3
7 8 0.04 165 14.92 353 869 4.17 / 672.78 2 11
Average= 4.15
(KJ/cycle)

Cycle 160 GMT 24/ 6/2023 6:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.40 30 14.88 536 239 0.24 / 664.55 2 3
2 7 2008.04 33 14.68 2971 1439 1.68 / 665.99 2 3
3 13 1575.48 20 14.70 2467 725 2.40 / 666.71 2 5
4 13 1006.88 20 14.75 1754 517 2.92 / 667.23 2 4
5 13 553.48 20 14.82 1144 339 3.26 / 667.57 2 4
6 13 124.28 20 14.93 555 166 3.43 / 667.73 2 3
7 8 0.00 165 14.93 355 875 4.30 / 668.61 2 11
Average= 4.15
(KJ/cycle)

Cycle 159 GMT 14/ 6/2023 8:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 30 14.89 494 221 0.22 / 660.32 2 3
2 7 2006.64 33 14.70 2975 1443 1.66 / 661.76 2 4
3 13 1586.52 20 14.70 2484 730 2.39 / 662.49 2 3
4 13 1008.52 20 14.75 1757 518 2.91 / 663.01 2 6
5 13 418.08 20 14.86 979 291 3.20 / 663.30 2 4
6 13 72.88 20 14.96 461 138 3.34 / 663.44 2 3
7 8 0.08 165 14.93 353 870 4.21 / 664.31 2 8
Average= 4.15
(KJ/cycle)

Cycle 158 GMT 4/ 6/2023 10:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 30 14.89 495 221 0.22 / 656.09 2 3
2 7 2004.52 33 14.70 2970 1441 1.66 / 657.53 2 3
3 13 1584.84 20 14.71 2471 727 2.39 / 658.26 2 3
4 13 992.92 20 14.76 1745 515 2.90 / 658.77 2 5
5 13 424.16 20 14.86 992 295 3.20 / 659.07 2 4
6 13 74.20 20 14.95 486 145 3.34 / 659.21 2 3
7 8 0.08 165 14.93 359 884 4.23 / 660.10 2 10
Average= 4.15
(KJ/cycle)

Cycle 157 GMT 25/ 5/2023 13: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 31 14.90 513 237 0.24 / 651.92 2 3
2 7 2004.64 33 14.70 2969 1440 1.68 / 653.36 2 3
3 13 1583.60 20 14.71 2468 726 2.40 / 654.09 2 3
4 13 873.84 20 14.79 1571 465 2.87 / 654.55 2 5
5 13 445.80 20 14.86 995 296 3.16 / 654.85 2 5
6 13 80.08 20 14.96 476 142 3.31 / 654.99 2 3
7 8 0.12 165 14.93 356 877 4.18 / 655.87 2 10
Average= 4.15
(KJ/cycle)

Cycle 156 GMT 15/ 5/2023 15: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 31 14.89 508 234 0.23 / 647.67 2 3
2 7 2008.76 34 14.69 2977 1487 1.72 / 649.16 2 4
3 13 1592.44 20 14.70 2493 733 2.45 / 649.89 2 3
4 13 995.64 20 14.76 1740 514 2.97 / 650.40 2 5
5 13 414.56 20 14.86 958 285 3.25 / 650.69 2 5
6 13 70.24 20 14.96 461 138 3.39 / 650.83 2 3
7 8 0.16 165 14.94 348 858 4.25 / 651.68 2 10
Average= 4.15
(KJ/cycle)

Cycle 155 GMT 5/ 5/2023 17:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 31 14.89 490 226 0.23 / 643.40 2 3
2 7 2003.52 33 14.70 2980 1446 1.67 / 644.84 2 3
3 13 1726.32 20 14.68 2653 779 2.45 / 645.62 2 4
4 13 968.52 20 14.77 1701 502 2.95 / 646.13 2 4
5 13 409.60 20 14.87 946 281 3.23 / 646.41 2 4
6 13 123.00 20 14.94 540 161 3.40 / 646.57 2 3
7 8 0.04 165 14.94 352 868 4.26 / 647.44 2 11
Average= 4.15
(KJ/cycle)

Cycle 154 GMT 25/ 4/2023 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.52 31 14.89 533 246 0.25 / 639.12 2 3
2 7 2005.20 34 14.69 2973 1485 1.73 / 640.61 2 4
3 13 1707.52 20 14.68 2646 777 2.51 / 641.39 2 4
4 13 953.64 20 14.77 1680 496 3.00 / 641.88 2 7
5 13 384.00 20 14.88 911 271 3.28 / 642.15 2 4
6 13 64.64 20 14.96 461 138 3.41 / 642.29 2 3
7 8 0.12 165 14.93 358 882 4.30 / 643.17 2 9
Average= 4.15
(KJ/cycle)

Cycle 153 GMT 15/ 4/2023 21:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.36 31 14.89 518 239 0.24 / 634.93 2 3
2 7 2003.88 33 14.70 2974 1443 1.68 / 636.37 2 3
3 13 1465.60 20 14.72 2334 687 2.37 / 637.06 2 4
4 13 931.92 20 14.76 1677 495 2.86 / 637.55 2 5
5 13 482.64 20 14.85 1056 314 3.18 / 637.86 2 4
6 13 92.80 20 14.95 505 151 3.33 / 638.02 2 3
7 8 0.04 165 14.93 350 862 4.19 / 638.88 2 9
Average= 4.15
(KJ/cycle)

Cycle 152 GMT 5/ 4/2023 23:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 31 14.90 525 242 0.24 / 630.70 2 3
2 7 2007.24 33 14.69 2981 1445 1.69 / 632.14 2 4
3 13 1611.12 20 14.70 2510 738 2.43 / 632.88 2 3
4 13 891.52 20 14.78 1598 472 2.90 / 633.35 2 5
5 13 469.56 20 14.85 1041 309 3.21 / 633.66 2 4
6 13 92.24 20 14.95 513 153 3.36 / 633.81 2 3
7 8 0.04 165 14.94 354 873 4.23 / 634.69 2 10
Average= 4.15
(KJ/cycle)

Cycle 151 GMT 27/ 3/2023 1:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 31 14.90 491 227 0.23 / 626.51 2 3
2 7 2003.92 33 14.70 2974 1443 1.67 / 627.96 2 3
3 13 1459.32 20 14.73 2323 684 2.35 / 628.64 2 4
4 13 923.20 20 14.77 1659 490 2.84 / 629.13 2 4
5 13 491.68 20 14.85 1059 315 3.16 / 629.44 2 5
6 13 93.28 20 14.96 489 146 3.30 / 629.59 2 3
7 8 0.32 165 14.94 350 863 4.17 / 630.45 2 9
Average= 4.15
(KJ/cycle)

Cycle 150 GMT 17/ 3/2023 3:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 31 14.90 519 240 0.24 / 622.29 2 3
2 7 2003.80 33 14.70 2984 1448 1.69 / 623.73 2 3
3 13 1576.44 20 14.71 2465 725 2.41 / 624.46 2 3
4 13 1002.28 20 14.77 1743 515 2.93 / 624.97 2 5
5 13 425.24 20 14.87 975 290 3.22 / 625.26 2 5
6 13 74.28 20 14.96 480 144 3.36 / 625.41 2 3
7 8 -0.04 165 14.94 356 878 4.24 / 626.29 2 12
Average= 4.15
(KJ/cycle)

Cycle 149 GMT 7/ 3/2023 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 31 14.90 507 234 0.23 / 618.08 2 3
2 7 2008.88 33 14.69 2985 1447 1.68 / 619.53 2 3
3 13 1472.96 20 14.72 2349 692 2.37 / 620.22 2 4
4 13 912.20 20 14.78 1619 479 2.85 / 620.70 2 6
5 13 479.48 20 14.85 1046 311 3.16 / 621.01 2 4
6 13 88.64 20 14.95 502 150 3.31 / 621.16 2 3
7 8 0.00 165 14.94 359 885 4.20 / 622.05 2 8
Average= 4.15
(KJ/cycle)

Cycle 148 GMT 25/ 2/2023 7:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 31 14.90 491 227 0.23 / 613.62 2 3
2 7 2012.36 33 14.70 2993 1452 1.68 / 615.07 2 3
3 13 1478.36 20 14.72 2339 689 2.37 / 615.76 2 4
4 13 1044.68 20 14.75 1796 530 2.90 / 616.29 2 6
5 13 458.12 20 14.86 1013 301 3.20 / 616.59 2 4
6 13 88.08 20 14.96 493 148 3.35 / 616.74 2 3
7 13 18.36 20 14.98 388 116 3.46 / 616.85 2 3
8 8 0.00 165 14.93 350 862 4.32 / 617.72 2 13
9 14 0.00 25 14.91 363 135 4.46 / 617.85 3 13
Average= 4.15
(KJ/cycle)

Cycle 147 GMT 15/ 2/2023 9: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 31 14.90 490 226 0.23 / 609.38 2 2
2 7 2003.64 33 14.70 2991 1451 1.68 / 610.83 2 3
3 13 1598.84 20 14.71 2494 734 2.41 / 611.56 2 5
4 13 995.92 20 14.77 1738 513 2.92 / 612.08 2 5
5 13 429.92 20 14.87 982 292 3.22 / 612.37 2 5
6 13 138.52 20 14.94 578 173 3.39 / 612.54 2 3
7 8 0.00 165 14.94 345 850 4.24 / 613.39 2 10
Average= 4.14
(KJ/cycle)

Cycle 146 GMT 5/ 2/2023 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 31 14.91 486 225 0.22 / 605.12 2 3
2 7 2004.52 33 14.70 2996 1453 1.68 / 606.57 2 3
3 13 1592.24 20 14.71 2480 730 2.41 / 607.30 2 3
4 13 1006.68 20 14.76 1753 517 2.93 / 607.82 2 4
5 13 433.16 20 14.87 1001 298 3.22 / 608.11 2 5
6 13 139.00 20 14.95 561 168 3.39 / 608.28 2 4
7 8 0.04 165 14.94 353 870 4.26 / 609.15 2 6
Average= 4.14
(KJ/cycle)

Cycle 145 GMT 26/ 1/2023 13:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.72 30 14.91 512 229 0.23 / 600.85 2 3
2 7 2007.52 33 14.70 2986 1449 1.68 / 602.30 2 4
3 13 1581.08 20 14.71 2495 734 2.41 / 603.03 2 4
4 13 994.20 20 14.76 1745 515 2.93 / 603.54 2 5
5 13 435.80 20 14.87 988 294 3.22 / 603.84 2 6
6 13 147.68 20 14.95 577 173 3.39 / 604.01 2 4
7 8 0.08 165 14.94 357 880 4.27 / 604.89 2 7
Average= 4.14
(KJ/cycle)

Cycle 144 GMT 16/ 1/2023 15:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 30 14.91 499 223 0.22 / 596.61 2 3
2 7 2005.44 33 14.71 2973 1443 1.67 / 598.05 2 4
3 13 1587.40 20 14.72 2488 732 2.40 / 598.78 2 5
4 13 993.32 20 14.77 1747 516 2.91 / 599.30 2 4
5 13 419.76 20 14.88 964 287 3.20 / 599.59 2 6
6 13 137.04 20 14.95 553 165 3.37 / 599.75 2 3
7 8 0.12 165 14.95 351 866 4.23 / 600.62 2 9
Average= 4.14
(KJ/cycle)

Cycle 143 GMT 6/ 1/2023 17:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 30 14.91 496 222 0.22 / 592.23 2 3
2 7 2003.40 33 14.70 2982 1447 1.67 / 593.67 2 4
3 13 1599.96 20 14.72 2494 734 2.40 / 594.41 2 4
4 13 1003.88 20 14.77 1745 515 2.92 / 594.92 2 6
5 13 425.24 20 14.88 981 292 3.21 / 595.22 2 4
6 13 136.88 20 14.95 576 172 3.38 / 595.39 2 3
7 8 0.60 165 14.95 351 866 4.25 / 596.25 2 7
8 14 0.60 25 14.93 352 131 4.38 / 596.38 2 10
Average= 4.14
(KJ/cycle)

Cycle 142 GMT 27/12/2022 19:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 30 14.91 492 220 0.22 / 587.98 2 3
2 7 2004.92 34 14.70 2982 1490 1.71 / 589.47 2 3
3 13 1580.48 20 14.71 2466 725 2.44 / 590.19 2 4
4 13 978.56 20 14.77 1704 503 2.94 / 590.70 2 6
5 13 400.80 20 14.89 935 278 3.22 / 590.98 2 4
6 13 121.40 20 14.96 538 161 3.38 / 591.14 2 3
7 8 0.00 165 14.95 352 868 4.25 / 592.01 2 11
Average= 4.14
(KJ/cycle)

Cycle 141 GMT 17/12/2022 21:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 30 14.91 502 225 0.22 / 583.76 2 3
2 7 2008.60 34 14.70 2973 1486 1.71 / 585.24 2 4
3 13 1468.68 20 14.73 2329 686 2.40 / 585.93 2 5
4 13 1026.52 20 14.76 1776 524 2.92 / 586.45 2 6
5 13 418.48 20 14.88 962 286 3.21 / 586.74 2 3
6 13 127.80 20 14.95 552 165 3.37 / 586.90 2 3
7 8 -0.04 165 14.95 346 853 4.23 / 587.76 2 10
Average= 4.14
(KJ/cycle)

Cycle 140 GMT 8/12/2022 0: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 30 14.92 478 214 0.21 / 579.57 2 3
2 7 2002.52 33 14.71 2971 1442 1.66 / 581.01 2 3
3 13 1459.12 20 14.74 2320 684 2.34 / 581.69 2 3
4 13 1027.84 20 14.76 1793 529 2.87 / 582.22 2 5
5 13 446.28 20 14.87 1010 300 3.17 / 582.52 2 4
6 13 85.00 20 14.97 474 142 3.31 / 582.66 2 3
7 8 0.00 165 14.96 352 869 4.18 / 583.53 2 10
Average= 4.14
(KJ/cycle)

Cycle 139 GMT 28/11/2022 2: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 30 14.91 479 214 0.21 / 575.29 2 3
2 7 2004.20 33 14.71 2981 1447 1.66 / 576.74 2 3
3 13 1741.60 20 14.69 2678 787 2.45 / 577.52 2 3
4 13 979.16 20 14.78 1725 510 2.96 / 578.03 2 5
5 13 409.72 20 14.89 966 288 3.25 / 578.32 2 4
6 13 129.92 20 14.96 555 166 3.41 / 578.49 2 3
7 8 -0.08 165 14.95 350 863 4.28 / 579.35 2 8
Average= 4.14
(KJ/cycle)

Cycle 138 GMT 18/11/2022 4:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 30 14.92 491 220 0.22 / 571.11 2 3
2 7 2011.04 33 14.71 2996 1454 1.67 / 572.57 2 3
3 13 1470.12 20 14.73 2350 692 2.37 / 573.26 2 4
4 13 926.76 20 14.78 1642 485 2.85 / 573.74 2 4
5 13 495.32 20 14.85 1063 316 3.17 / 574.06 2 5
6 13 102.08 20 14.97 515 154 3.32 / 574.21 2 3
7 8 0.12 165 14.95 350 863 4.19 / 575.08 2 9
Average= 4.14
(KJ/cycle)

Cycle 137 GMT 8/11/2022 6:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 30 14.92 493 221 0.22 / 566.85 2 3
2 7 2004.28 33 14.70 2981 1446 1.67 / 568.30 2 3
3 13 1591.48 20 14.72 2502 737 2.40 / 569.04 2 3
4 13 1007.08 20 14.77 1758 519 2.92 / 569.56 2 5
5 13 433.64 20 14.88 984 293 3.22 / 569.85 2 5
6 13 139.68 20 14.96 571 171 3.39 / 570.02 2 3
7 8 -0.04 165 14.96 353 871 4.26 / 570.89 2 9
Average= 4.14
(KJ/cycle)

Cycle 136 GMT 29/10/2022 8:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 30 14.92 474 212 0.21 / 562.60 2 3
2 7 2008.40 34 14.70 2983 1491 1.70 / 564.09 2 3
3 13 1579.40 20 14.71 2484 731 2.43 / 564.83 2 6
4 13 975.60 20 14.78 1712 506 2.94 / 565.33 2 4
5 13 407.84 20 14.89 956 285 3.22 / 565.62 2 3
6 13 75.96 20 14.98 496 149 3.37 / 565.77 2 3
7 8 0.08 165 14.96 352 869 4.24 / 566.63 2 10
Average= 4.14
(KJ/cycle)

Cycle 135 GMT 19/10/2022 10: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 30 14.93 481 215 0.22 / 558.42 2 3
2 7 2010.40 33 14.70 2990 1450 1.67 / 559.87 2 3
3 13 1476.00 20 14.74 2346 692 2.36 / 560.56 2 4
4 13 1036.16 20 14.77 1783 527 2.88 / 561.09 2 5
5 13 437.60 20 14.88 988 294 3.18 / 561.38 2 5
6 13 88.08 20 14.98 492 147 3.33 / 561.53 2 3
7 8 0.08 165 14.96 349 861 4.19 / 562.39 2 10
Average= 4.14
(KJ/cycle)

Cycle 134 GMT 9/10/2022 12:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 30 14.92 488 218 0.22 / 554.17 2 2
2 7 2010.12 33 14.71 2994 1453 1.67 / 555.62 2 4
3 13 1605.92 20 14.72 2499 736 2.41 / 556.35 2 3
4 13 1030.52 20 14.77 1780 526 2.93 / 556.88 2 5
5 13 442.64 20 14.88 1000 298 3.23 / 557.18 2 5
6 13 84.72 20 14.98 494 148 3.38 / 557.33 2 3
7 8 0.12 165 14.96 356 879 4.26 / 558.20 2 10
Average= 4.13
(KJ/cycle)

Cycle 133 GMT 29/ 9/2022 14:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 30 14.93 485 217 0.22 / 549.96 2 3
2 7 2010.88 34 14.70 2985 1492 1.71 / 551.45 2 3
3 13 1475.96 20 14.74 2349 692 2.40 / 552.14 2 4
4 13 911.16 20 14.79 1625 481 2.88 / 552.62 2 5
5 13 464.12 20 14.87 1034 308 3.19 / 552.93 2 4
6 13 81.84 20 14.98 491 147 3.34 / 553.08 2 3
7 8 0.16 165 14.96 353 871 4.21 / 553.95 2 11
Average= 4.13
(KJ/cycle)

Cycle 132 GMT 19/ 9/2022 16: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 30 14.92 491 220 0.22 / 545.73 2 3
2 7 2004.80 33 14.71 2982 1448 1.67 / 547.17 2 3
3 13 1468.44 20 14.74 2345 691 2.36 / 547.87 2 3
4 13 1054.68 20 14.76 1824 538 2.90 / 548.40 2 4
5 13 455.36 20 14.87 1029 306 3.20 / 548.71 2 4
6 13 86.76 20 14.98 507 152 3.35 / 548.86 2 3
7 8 0.00 165 14.96 355 876 4.23 / 549.74 2 11
Average= 4.13
(KJ/cycle)

Cycle 131 GMT 9/ 9/2022 18: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 30 14.93 483 216 0.22 / 541.48 2 3
2 7 2006.76 33 14.71 2982 1448 1.66 / 542.93 2 4
3 13 1606.56 20 14.72 2511 739 2.40 / 543.67 2 4
4 13 1011.36 20 14.78 1755 519 2.92 / 544.19 2 4
5 13 436.32 20 14.89 997 297 3.22 / 544.49 2 4
6 13 84.64 20 14.98 490 147 3.37 / 544.63 2 3
7 8 0.00 165 14.96 354 874 4.24 / 545.51 2 9
Average= 4.13
(KJ/cycle)

Cycle 130 GMT 30/ 8/2022 20:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 30 14.93 500 224 0.22 / 537.25 2 3
2 7 2002.08 33 14.71 2984 1449 1.67 / 538.70 2 3
3 13 1591.36 20 14.73 2489 733 2.41 / 539.43 2 3
4 13 1005.36 20 14.78 1743 515 2.92 / 539.94 2 4
5 13 418.00 20 14.90 966 288 3.21 / 540.23 2 4
6 13 127.72 20 14.97 554 166 3.37 / 540.40 2 3
7 8 0.08 165 14.97 352 869 4.24 / 541.27 2 10
Average= 4.13
(KJ/cycle)

Cycle 129 GMT 20/ 8/2022 22:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 30 14.93 499 224 0.22 / 532.98 2 3
2 7 2005.20 33 14.72 2977 1446 1.67 / 534.42 2 3
3 13 1592.88 20 14.72 2494 734 2.40 / 535.16 2 3
4 13 1005.44 20 14.78 1753 518 2.92 / 535.68 2 5
5 13 417.32 20 14.90 975 291 3.21 / 535.97 2 4
6 13 138.44 20 14.96 586 175 3.39 / 536.14 2 3
7 8 0.08 165 14.97 357 882 4.27 / 537.02 2 7
Average= 4.13
(KJ/cycle)

Cycle 128 GMT 11/ 8/2022 0:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 30 14.93 490 219 0.22 / 528.73 2 3
2 7 2002.60 33 14.71 2988 1450 1.67 / 530.18 2 3
3 13 1590.96 20 14.73 2476 729 2.40 / 530.91 2 5
4 13 995.28 20 14.78 1740 514 2.91 / 531.42 2 5
5 13 415.92 20 14.90 966 288 3.20 / 531.71 2 4
6 13 128.96 20 14.97 561 168 3.37 / 531.88 2 3
7 8 0.00 165 14.97 355 877 4.25 / 532.75 2 11
Average= 4.13
(KJ/cycle)

Cycle 127 GMT 1/ 8/2022 2:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 30 14.93 482 216 0.22 / 524.50 2 3
2 7 2008.88 33 14.72 2982 1449 1.66 / 525.95 2 3
3 13 1585.36 20 14.73 2477 730 2.39 / 526.68 2 3
4 13 989.60 20 14.79 1723 510 2.90 / 527.19 2 5
5 13 410.08 20 14.90 952 284 3.19 / 527.47 2 4
6 13 129.40 20 14.97 550 165 3.35 / 527.63 2 4
7 8 0.08 165 14.97 354 874 4.23 / 528.51 2 8
Average= 4.13
(KJ/cycle)

Cycle 126 GMT 22/ 7/2022 4:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 30 14.93 493 221 0.22 / 520.26 2 3
2 7 2005.80 34 14.71 2982 1491 1.71 / 521.75 2 3
3 13 1461.16 20 14.75 2330 687 2.40 / 522.44 2 4
4 13 1023.04 20 14.78 1777 525 2.92 / 522.97 2 4
5 13 421.04 20 14.90 979 292 3.22 / 523.26 2 5
6 13 70.76 20 14.99 482 145 3.36 / 523.40 2 3
7 8 0.08 165 14.97 356 879 4.24 / 524.28 2 9
Average= 4.13
(KJ/cycle)

Cycle 125 GMT 12/ 7/2022 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 30 14.93 486 218 0.22 / 516.07 2 3
2 7 2007.04 33 14.72 2990 1452 1.67 / 517.52 2 3
3 13 1472.16 20 14.75 2336 689 2.36 / 518.21 2 3
4 13 919.44 20 14.80 1640 485 2.84 / 518.69 2 5
5 13 468.36 20 14.88 1055 314 3.16 / 519.01 2 4
6 13 90.88 20 14.99 500 150 3.31 / 519.16 2 3
7 8 0.00 165 14.96 358 884 4.19 / 520.04 2 8
Average= 4.13
(KJ/cycle)

Cycle 124 GMT 2/ 7/2022 8:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 30 14.93 492 220 0.22 / 511.80 2 2
2 7 2008.80 34 14.70 2985 1492 1.71 / 513.30 2 3
3 13 1466.16 20 14.75 2351 694 2.41 / 513.99 2 5
4 13 1037.16 20 14.77 1798 531 2.94 / 514.52 2 4
5 13 436.00 20 14.89 991 295 3.23 / 514.82 2 6
6 13 86.40 20 14.99 504 151 3.38 / 514.97 2 3
7 8 0.00 165 14.97 357 882 4.26 / 515.85 2 9
Average= 4.13
(KJ/cycle)

Cycle 123 GMT 22/ 6/2022 10:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 30 14.93 502 225 0.22 / 507.66 2 2
2 7 2003.40 33 14.72 2995 1455 1.68 / 509.11 2 3
3 13 1458.32 20 14.75 2332 688 2.37 / 509.80 2 6
4 13 883.72 20 14.81 1588 470 2.84 / 510.27 2 5
5 13 337.12 20 14.92 872 260 3.10 / 510.53 2 4
6 13 103.96 20 14.98 531 159 3.26 / 510.69 2 3
7 8 0.16 165 14.97 361 892 4.15 / 511.58 2 11
Average= 4.13
(KJ/cycle)

Cycle 122 GMT 12/ 6/2022 12:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 30 14.93 503 225 0.23 / 503.46 2 3
2 7 2004.48 33 14.72 2985 1450 1.68 / 504.91 2 4
3 13 1584.64 20 14.74 2498 736 2.41 / 505.65 2 3
4 13 883.12 20 14.82 1603 475 2.89 / 506.12 2 6
5 13 459.12 20 14.89 1038 309 3.20 / 506.43 2 4
6 13 86.80 20 14.99 482 145 3.34 / 506.58 2 3
7 8 0.16 165 14.97 348 860 4.20 / 507.43 2 7
Average= 4.13
(KJ/cycle)

Cycle 121 GMT 2/ 6/2022 14:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 30 14.93 496 222 0.22 / 499.22 2 3
2 7 2005.96 33 14.71 2976 1445 1.67 / 500.66 2 3
3 13 1572.40 20 14.73 2477 730 2.40 / 501.39 2 3
4 13 867.52 20 14.82 1585 470 2.87 / 501.86 2 4
5 13 430.80 20 14.90 1000 298 3.16 / 502.16 2 4
6 13 136.28 20 14.97 586 175 3.34 / 502.34 2 4
7 8 0.00 165 14.97 364 899 4.24 / 503.23 2 11
Average= 4.12
(KJ/cycle)

Cycle 120 GMT 23/ 5/2022 16:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 30 14.92 505 226 0.23 / 495.00 2 3
2 7 2004.80 33 14.72 2979 1447 1.67 / 496.44 2 4
3 13 1469.28 20 14.75 2351 694 2.37 / 497.14 2 3
4 13 1041.84 20 14.78 1798 531 2.90 / 497.67 2 5
5 13 447.76 20 14.89 1021 304 3.20 / 497.97 2 6
6 13 93.40 20 14.99 500 150 3.35 / 498.12 2 3
7 8 0.08 165 14.98 353 873 4.22 / 499.00 2 8
Average= 4.12
(KJ/cycle)

Cycle 119 GMT 13/ 5/2022 18:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 30 14.93 494 221 0.22 / 490.70 2 2
2 7 2003.36 33 14.72 2975 1445 1.67 / 492.15 2 3
3 13 1723.32 20 14.71 2668 785 2.45 / 492.93 2 3
4 13 964.24 20 14.81 1687 500 2.95 / 493.43 2 5
5 13 399.84 20 14.91 956 285 3.24 / 493.72 2 5
6 13 127.40 20 14.98 554 166 3.40 / 493.88 2 4
7 8 0.08 165 14.97 359 887 4.29 / 494.77 2 11
Average= 4.12
(KJ/cycle)

Cycle 118 GMT 3/ 5/2022 20:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 30 14.94 499 224 0.22 / 486.55 2 3
2 7 2003.16 33 14.73 2995 1456 1.68 / 488.00 2 3
3 13 1478.24 20 14.75 2352 694 2.37 / 488.70 2 6
4 13 920.80 20 14.81 1647 488 2.86 / 489.19 2 7
5 13 364.60 20 14.92 901 269 3.13 / 489.45 2 4
6 13 112.88 20 14.99 529 159 3.29 / 489.61 2 3
7 8 -0.08 165 14.97 352 869 4.16 / 490.48 2 8
Average= 4.12
(KJ/cycle)

Cycle 117 GMT 23/ 4/2022 22:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 30 14.93 495 222 0.22 / 482.39 2 2
2 7 2002.64 33 14.72 2981 1448 1.67 / 483.84 2 4
3 13 1452.08 20 14.76 2329 688 2.36 / 484.53 2 3
4 13 904.64 20 14.82 1621 480 2.84 / 485.01 2 7
5 13 348.72 20 14.93 869 259 3.10 / 485.27 2 4
6 13 102.12 20 15.00 522 157 3.25 / 485.43 2 3
7 8 0.20 165 14.98 363 897 4.15 / 486.32 2 9
Average= 4.12
(KJ/cycle)

Cycle 116 GMT 14/ 4/2022 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 30 14.93 502 225 0.22 / 478.14 2 2
2 7 2004.20 33 14.73 2992 1454 1.68 / 479.59 2 3
3 13 1569.12 20 14.74 2467 727 2.41 / 480.32 2 5
4 13 986.44 20 14.81 1729 512 2.92 / 480.83 2 4
5 13 394.64 20 14.92 945 282 3.20 / 481.11 2 4
6 13 129.32 20 14.98 581 174 3.37 / 481.29 2 3
7 8 0.12 165 14.98 359 887 4.26 / 482.17 2 12
Average= 4.12
(KJ/cycle)

Cycle 115 GMT 4/ 4/2022 2:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 30 14.93 507 227 0.23 / 473.90 2 2
2 7 2006.40 34 14.72 3004 1503 1.73 / 475.40 2 3
3 13 1468.28 20 14.75 2351 694 2.42 / 476.10 2 5
4 13 905.72 20 14.81 1645 487 2.91 / 476.59 2 4
5 13 340.36 20 14.93 860 257 3.17 / 476.84 2 4
6 13 100.36 20 14.99 534 160 3.33 / 477.00 2 4
7 8 0.12 165 14.97 368 909 4.24 / 477.91 2 12
Average= 4.12
(KJ/cycle)

Cycle 114 GMT 25/ 3/2022 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 30 14.93 502 225 0.22 / 469.69 2 2
2 7 2005.56 33 14.72 2984 1450 1.67 / 471.14 2 3
3 13 1462.20 20 14.76 2334 689 2.36 / 471.83 2 4
4 13 908.32 20 14.82 1640 486 2.85 / 472.32 2 5
5 13 455.88 20 14.90 1020 304 3.15 / 472.62 2 4
6 13 80.56 20 15.00 490 147 3.30 / 472.77 2 4
7 8 0.00 165 14.98 367 907 4.21 / 473.67 2 8
Average= 4.12
(KJ/cycle)

Cycle 113 GMT 15/ 3/2022 6:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.76 30 14.93 530 237 0.24 / 465.37 2 2
2 7 2003.44 33 14.73 2978 1448 1.68 / 466.82 2 3
3 13 1588.28 20 14.74 2499 737 2.42 / 467.56 2 5
4 13 988.04 20 14.81 1722 510 2.93 / 468.07 2 5
5 13 526.76 20 14.88 1126 335 3.27 / 468.40 2 4
6 13 106.24 20 14.99 535 160 3.43 / 468.56 2 3
7 8 0.20 165 14.98 366 905 4.33 / 469.47 2 11
Average= 4.12
(KJ/cycle)

Cycle 112 GMT 5/ 3/2022 8:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 30 14.94 506 227 0.23 / 461.07 2 2
2 7 2002.60 33 14.73 2993 1455 1.68 / 462.53 2 4
3 13 1580.76 20 14.74 2480 731 2.41 / 463.26 2 4
4 13 987.52 20 14.81 1734 514 2.93 / 463.77 2 6
5 13 404.12 20 14.92 969 289 3.22 / 464.06 2 4
6 13 128.64 20 14.99 576 173 3.39 / 464.23 2 4
7 8 0.16 165 14.98 364 900 4.29 / 465.13 2 9
Average= 4.12
(KJ/cycle)

Cycle 111 GMT 23/ 2/2022 10:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 30 14.94 507 227 0.23 / 456.90 2 3
2 7 2002.92 33 14.73 2969 1443 1.67 / 458.34 2 5
3 13 1444.48 20 14.77 2302 680 2.35 / 459.02 2 5
4 13 891.20 20 14.83 1598 474 2.82 / 459.50 2 7
5 13 448.20 20 14.91 1026 306 3.13 / 459.80 2 4
6 13 85.00 20 15.00 503 151 3.28 / 459.95 2 3
7 8 0.20 165 14.98 361 892 4.17 / 460.85 2 10
Average= 4.11
(KJ/cycle)

Cycle 110 GMT 13/ 2/2022 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 30 14.94 504 226 0.23 / 452.62 2 3
2 7 2005.04 33 14.73 2979 1448 1.67 / 454.07 2 4
3 13 1602.52 20 14.74 2521 743 2.42 / 454.81 2 4
4 13 1002.08 20 14.81 1748 518 2.93 / 455.33 2 5
5 13 424.84 20 14.92 978 292 3.23 / 455.62 2 4
6 13 136.24 20 14.99 584 175 3.40 / 455.80 2 3
7 8 0.00 165 14.99 355 878 4.28 / 456.67 2 10
Average= 4.11
(KJ/cycle)

Cycle 109 GMT 3/ 2/2022 15: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 30 14.94 498 223 0.22 / 448.34 2 3
2 7 2008.72 33 14.73 2990 1453 1.68 / 449.79 2 3
3 13 1589.72 20 14.74 2496 736 2.41 / 450.53 2 5
4 13 998.52 20 14.81 1738 515 2.93 / 451.04 2 5
5 13 410.40 20 14.92 963 287 3.21 / 451.33 2 4
6 13 126.08 20 14.99 567 170 3.38 / 451.50 2 4
7 8 0.16 165 14.98 362 895 4.28 / 452.39 2 11
Average= 4.11
(KJ/cycle)

Cycle 108 GMT 24/ 1/2022 17: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 30 14.95 483 217 0.22 / 444.02 2 2
2 7 2003.92 34 14.72 2987 1495 1.71 / 445.52 2 4
3 13 1575.04 20 14.74 2484 732 2.44 / 446.25 2 4
4 13 991.08 20 14.81 1731 513 2.96 / 446.76 2 4
5 13 396.96 20 14.92 961 287 3.24 / 447.05 2 5
6 13 119.60 20 14.99 559 168 3.41 / 447.22 2 4
7 8 0.00 165 14.99 362 895 4.31 / 448.11 2 11
Average= 4.11
(KJ/cycle)

Cycle 107 GMT 14/ 1/2022 19:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 30 14.94 500 224 0.22 / 439.80 2 2
2 7 2005.76 34 14.73 2992 1498 1.72 / 441.30 2 4
3 13 1464.60 20 14.77 2338 691 2.41 / 441.99 2 4
4 13 902.04 20 14.82 1637 485 2.90 / 442.47 2 5
5 13 457.44 20 14.91 1031 307 3.21 / 442.78 2 4
6 13 79.96 20 15.01 482 145 3.35 / 442.92 2 3
7 8 0.12 165 14.99 357 883 4.23 / 443.81 2 12
Average= 4.11
(KJ/cycle)

Cycle 106 GMT 4/ 1/2022 21:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 30 14.94 505 226 0.23 / 435.52 2 3
2 7 2006.64 33 14.73 2981 1449 1.68 / 436.97 2 3
3 13 1588.36 20 14.74 2507 739 2.41 / 437.71 2 4
4 13 979.32 20 14.82 1724 511 2.93 / 438.22 2 5
5 13 405.48 20 14.92 952 284 3.21 / 438.51 2 3
6 13 123.44 20 14.99 563 169 3.38 / 438.68 2 3
7 8 0.16 165 14.99 363 898 4.28 / 439.57 2 10
Average= 4.11
(KJ/cycle)

Cycle 105 GMT 25/12/2021 23:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 30 14.95 499 224 0.22 / 431.22 2 3
2 7 2004.36 33 14.74 2993 1456 1.68 / 432.68 2 3
3 13 1585.80 20 14.75 2498 737 2.42 / 433.42 2 5
4 13 988.84 20 14.81 1738 515 2.93 / 433.93 2 4
5 13 416.04 20 14.93 963 288 3.22 / 434.22 2 4
6 13 128.52 20 15.00 567 170 3.39 / 434.39 2 3
7 8 0.08 165 14.99 368 910 4.30 / 435.30 2 10
Average= 4.11
(KJ/cycle)

Cycle 104 GMT 16/12/2021 1:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 30 14.95 499 224 0.22 / 426.99 2 3
2 7 2004.72 34 14.73 2989 1497 1.72 / 428.49 2 3
3 13 1450.64 20 14.77 2331 689 2.41 / 429.18 2 5
4 13 1001.16 20 14.81 1754 520 2.93 / 429.70 2 3
5 13 407.48 20 14.93 956 285 3.21 / 429.98 2 4
6 13 76.32 20 15.02 472 142 3.36 / 430.12 2 3
7 8 0.12 165 14.99 354 876 4.23 / 431.00 2 12
Average= 4.10
(KJ/cycle)

Cycle 103 GMT 6/12/2021 3:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 30 14.95 498 223 0.22 / 422.70 2 2
2 7 2007.92 33 14.74 2998 1458 1.68 / 424.16 2 3
3 13 1582.36 20 14.75 2496 736 2.42 / 424.90 2 4
4 13 1003.20 20 14.81 1746 517 2.94 / 425.41 2 6
5 13 405.60 20 14.93 963 288 3.22 / 425.70 2 4
6 13 128.24 20 15.00 580 174 3.40 / 425.88 2 3
7 8 0.08 165 15.00 360 891 4.29 / 426.77 2 11
Average= 4.10
(KJ/cycle)

Cycle 102 GMT 26/11/2021 5:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 30 14.96 505 227 0.23 / 418.41 2 3
2 7 2006.84 33 14.73 2999 1458 1.68 / 419.87 2 3
3 13 1588.72 20 14.74 2513 741 2.43 / 420.61 2 3
4 13 1000.40 20 14.81 1753 519 2.94 / 421.13 2 7
5 13 429.72 20 14.92 994 297 3.24 / 421.42 2 4
6 13 134.48 20 14.99 580 174 3.41 / 421.60 2 3
7 8 0.00 165 15.00 357 884 4.30 / 422.48 2 7
Average= 4.10
(KJ/cycle)

Cycle 101 GMT 16/11/2021 7:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 30 14.95 515 231 0.23 / 414.15 2 3
2 7 2004.08 33 14.74 2999 1459 1.69 / 415.61 2 3
3 13 1588.16 20 14.74 2517 742 2.43 / 416.36 2 4
4 13 891.80 20 14.83 1620 480 2.91 / 416.84 2 7
5 13 452.84 20 14.92 1018 304 3.22 / 417.14 2 4
6 13 87.72 20 15.01 510 153 3.37 / 417.29 2 3
7 8 0.08 165 14.99 359 888 4.26 / 418.18 2 12
Average= 4.10
(KJ/cycle)

Cycle 100 GMT 6/11/2021 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 30 14.96 501 225 0.22 / 409.91 2 3
2 7 2002.88 33 14.74 2995 1457 1.68 / 411.37 2 3
3 13 1460.08 20 14.77 2343 692 2.37 / 412.06 2 4
4 13 901.00 20 14.83 1626 482 2.86 / 412.54 2 5
5 13 466.80 20 14.91 1056 315 3.17 / 412.86 2 4
6 13 92.12 20 15.01 531 159 3.33 / 413.02 2 3
7 8 0.04 165 14.99 367 908 4.24 / 413.92 2 11
Average= 4.10
(KJ/cycle)

Cycle 99 GMT 27/10/2021 12: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 30 14.95 502 225 0.23 / 405.62 2 2
2 7 2002.04 33 14.74 2994 1456 1.68 / 407.08 2 3
3 13 1577.28 19 14.75 2518 706 2.39 / 407.79 2 5
4 13 995.20 19 14.82 1741 490 2.88 / 408.28 2 4
5 13 552.36 19 14.89 1174 332 3.21 / 408.61 2 4
6 13 129.56 19 15.00 579 165 3.37 / 408.77 2 3
7 8 0.12 165 15.00 369 913 4.29 / 409.69 2 8
Average= 4.10
(KJ/cycle)

Cycle 98 GMT 17/10/2021 14: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 30 14.94 496 222 0.22 / 401.26 2 2
2 7 2003.12 33 14.74 2992 1455 1.68 / 402.72 2 4
3 13 1592.20 19 14.75 2512 704 2.38 / 403.42 2 5
4 13 1011.32 19 14.81 1769 498 2.88 / 403.92 2 4
5 13 429.52 19 14.93 1002 284 3.16 / 404.20 2 5
6 13 148.80 19 15.00 606 173 3.34 / 404.37 2 3
7 13 16.32 19 15.03 412 118 3.45 / 404.49 2 3
8 8 -0.16 165 14.99 366 905 4.36 / 405.40 2 13
Average= 4.09
(KJ/cycle)

Cycle 97 GMT 7/10/2021 16:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 30 14.96 499 224 0.22 / 396.76 2 2
2 7 2005.32 33 14.74 2996 1457 1.68 / 398.22 2 3
3 13 1598.04 19 14.75 2505 702 2.38 / 398.92 2 4
4 13 1014.80 19 14.81 1765 497 2.88 / 399.42 2 5
5 13 439.68 19 14.92 1004 285 3.16 / 399.70 2 4
6 13 147.68 19 15.00 608 173 3.34 / 399.88 2 4
7 13 33.84 19 15.02 434 124 3.46 / 400.00 2 3
8 8 0.00 165 14.99 365 903 4.36 / 400.90 2 12
9 14 0.00 25 14.97 362 135 4.50 / 401.04 2 12
Average= 4.09
(KJ/cycle)

Cycle 96 GMT 27/ 9/2021 18: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 30 14.96 483 217 0.22 / 392.62 2 3
2 7 2009.16 33 14.74 2996 1457 1.67 / 394.08 2 3
3 13 1461.32 19 14.77 2348 659 2.33 / 394.73 2 4
4 13 911.00 19 14.83 1632 460 2.79 / 395.19 2 6
5 13 481.24 19 14.91 1068 303 3.10 / 395.50 2 4
6 13 105.24 19 15.01 537 153 3.25 / 395.65 2 3
7 8 0.08 165 15.00 359 889 4.14 / 396.54 2 9
Average= 4.09
(KJ/cycle)

Cycle 95 GMT 17/ 9/2021 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 30 14.97 491 221 0.22 / 388.40 2 3
2 7 2007.40 33 14.74 2990 1454 1.67 / 389.86 2 4
3 13 1581.64 19 14.75 2508 703 2.38 / 390.56 2 4
4 13 995.52 19 14.82 1751 493 2.87 / 391.05 2 4
5 13 431.96 19 14.93 995 282 3.15 / 391.33 2 4
6 13 139.16 19 15.00 593 169 3.32 / 391.50 2 3
7 8 0.16 165 15.00 363 898 4.22 / 392.40 2 10
Average= 4.09
(KJ/cycle)

Cycle 94 GMT 7/ 9/2021 21:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 30 14.97 509 229 0.23 / 384.22 2 2
2 7 2004.20 33 14.74 2992 1455 1.68 / 385.68 2 4
3 13 1465.20 19 14.78 2344 658 2.34 / 386.33 2 3
4 13 1038.40 19 14.81 1819 512 2.85 / 386.85 2 4
5 13 460.60 19 14.92 1042 295 3.15 / 387.14 2 5
6 13 101.96 19 15.02 534 152 3.30 / 387.29 2 4
7 8 0.08 165 15.01 358 887 4.19 / 388.18 2 9
Average= 4.09
(KJ/cycle)

Cycle 93 GMT 28/ 8/2021 23:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 30 14.97 487 219 0.22 / 380.05 2 3
2 7 2003.56 34 14.73 2993 1499 1.72 / 381.55 2 3
3 13 1455.48 19 14.78 2337 656 2.37 / 382.21 2 4
4 13 895.84 19 14.85 1616 456 2.83 / 382.66 2 6
5 13 457.88 19 14.92 1044 296 3.13 / 382.96 2 4
6 13 94.76 19 15.02 521 149 3.27 / 383.11 2 4
7 8 0.00 165 15.01 358 887 4.16 / 383.99 2 8
Average= 4.09
(KJ/cycle)

Cycle 92 GMT 19/ 8/2021 1:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 30 14.97 499 224 0.22 / 375.83 2 2
2 7 2006.48 34 14.74 2983 1495 1.72 / 377.32 2 3
3 13 1578.36 19 14.75 2493 699 2.42 / 378.02 2 4
4 13 985.88 19 14.83 1734 489 2.91 / 378.51 2 5
5 13 406.00 19 14.94 968 275 3.18 / 378.78 2 5
6 13 130.72 19 15.01 575 164 3.35 / 378.95 2 3
7 8 0.08 165 15.01 357 884 4.23 / 379.83 2 7
Average= 4.08
(KJ/cycle)

Cycle 91 GMT 9/ 8/2021 3:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 30 14.96 495 222 0.22 / 371.67 2 2
2 7 2003.40 33 14.74 2992 1455 1.68 / 373.13 2 4
3 13 1466.60 19 14.78 2349 660 2.34 / 373.79 2 4
4 13 924.72 19 14.84 1651 466 2.80 / 374.25 2 5
5 13 484.96 19 14.92 1075 305 3.11 / 374.56 2 4
6 13 106.32 19 15.02 540 154 3.26 / 374.71 2 3
7 8 0.12 165 15.01 360 892 4.15 / 375.60 2 12
Average= 4.08
(KJ/cycle)

Cycle 90 GMT 30/ 7/2021 5:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 30 14.97 501 225 0.22 / 367.41 2 2
2 7 2008.40 31 14.76 3008 1376 1.60 / 368.79 2 3
3 13 1588.32 18 14.77 2529 672 2.27 / 369.46 2 4
4 13 1026.36 18 14.83 1797 480 2.75 / 369.94 2 5
5 13 582.00 18 14.91 1207 324 3.08 / 370.26 2 4
6 13 153.56 18 15.01 618 167 3.24 / 370.43 2 4
7 13 37.52 18 15.04 439 119 3.36 / 370.55 2 3
8 8 -0.08 165 15.00 363 898 4.26 / 371.45 2 9
Average= 4.08
(KJ/cycle)

Cycle 89 GMT 20/ 7/2021 7:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 30 14.97 502 225 0.23 / 363.17 2 3
2 7 2007.12 32 14.76 3000 1417 1.64 / 364.59 2 3
3 13 1586.92 18 14.78 2516 669 2.31 / 365.26 2 3
4 13 1027.92 18 14.83 1791 478 2.79 / 365.74 2 4
5 13 487.68 18 14.93 1077 289 3.08 / 366.03 2 4
6 13 132.12 18 15.02 568 154 3.23 / 366.18 2 3
7 13 34.96 18 15.04 432 117 3.35 / 366.30 2 3
8 8 0.04 165 15.01 359 889 4.24 / 367.19 2 8
Average= 4.08
(KJ/cycle)

Cycle 88 GMT 10/ 7/2021 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 30 14.98 490 220 0.22 / 358.91 2 3
2 7 2007.12 31 14.76 3000 1373 1.59 / 360.29 2 3
3 13 1592.04 18 14.78 2530 673 2.27 / 360.96 2 3
4 13 1030.40 18 14.83 1800 480 2.75 / 361.44 2 5
5 13 607.32 18 14.90 1236 331 3.08 / 361.77 2 4
6 13 167.08 18 15.01 635 172 3.25 / 361.94 2 3
7 13 19.64 18 15.05 407 110 3.36 / 362.05 2 3
8 8 0.08 165 15.00 362 896 4.26 / 362.95 2 10
Average= 4.08
(KJ/cycle)

Cycle 87 GMT 30/ 6/2021 11:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.84 30 14.98 523 235 0.24 / 354.50 2 3
2 7 2003.68 31 14.77 2985 1367 1.60 / 355.87 2 4
3 13 1603.68 18 14.78 2531 673 2.28 / 356.54 2 3
4 13 1046.32 18 14.83 1812 484 2.76 / 357.03 2 4
5 13 619.48 18 14.90 1258 337 3.10 / 357.36 2 4
6 13 181.88 18 15.01 666 180 3.28 / 357.54 2 4
7 13 22.76 18 15.05 419 114 3.39 / 357.66 2 3
8 8 0.00 165 15.01 364 902 4.29 / 358.56 2 12
9 14 0.00 25 14.99 356 133 4.42 / 358.69 3 11
Average= 4.08
(KJ/cycle)

Cycle 86 GMT 20/ 6/2021 13:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 30 14.96 508 228 0.23 / 350.24 2 2
2 7 2003.88 31 14.77 2988 1368 1.60 / 351.60 2 3
3 13 1579.56 18 14.79 2507 667 2.26 / 352.27 2 3
4 13 1015.92 18 14.85 1775 474 2.74 / 352.75 2 5
5 13 593.04 18 14.91 1215 326 3.06 / 353.07 2 5
6 13 170.16 18 15.01 638 172 3.24 / 353.24 2 4
7 13 37.04 18 15.05 442 120 3.36 / 353.36 2 3
8 8 -0.04 165 15.01 365 904 4.26 / 354.27 2 13
Average= 4.07
(KJ/cycle)

Cycle 85 GMT 10/ 6/2021 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 30 14.98 517 232 0.23 / 345.97 2 2
2 7 2003.64 31 14.78 2979 1365 1.60 / 347.33 2 3
3 13 1594.20 18 14.78 2520 670 2.27 / 348.00 2 4
4 13 1034.96 18 14.84 1811 484 2.75 / 348.49 2 4
5 13 600.68 18 14.91 1232 331 3.08 / 348.82 2 5
6 13 167.04 18 15.01 638 172 3.25 / 348.99 2 3
7 13 18.88 18 15.06 406 110 3.36 / 349.10 2 3
8 8 0.04 165 15.01 366 906 4.27 / 350.01 2 11
Average= 4.07
(KJ/cycle)

Cycle 84 GMT 31/ 5/2021 17: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 30 14.98 506 227 0.23 / 341.77 2 2
2 7 2007.56 31 14.78 2994 1372 1.60 / 343.14 2 4
3 13 1603.64 18 14.78 2542 676 2.28 / 343.82 2 3
4 13 1173.92 18 14.81 1987 530 2.81 / 344.35 2 4
5 13 581.88 18 14.91 1207 324 3.13 / 344.67 2 5
6 13 162.92 18 15.02 631 171 3.30 / 344.84 2 4
7 8 0.04 165 15.03 360 893 4.19 / 345.74 2 9
Average= 4.07
(KJ/cycle)

Cycle 83 GMT 21/ 5/2021 18:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 30 14.99 504 227 0.23 / 337.60 2 2
2 7 2003.72 31 14.78 2997 1373 1.60 / 338.97 2 3
3 13 1593.36 18 14.79 2512 669 2.27 / 339.64 2 4
4 13 1034.52 18 14.84 1815 485 2.75 / 340.12 2 5
5 13 600.24 18 14.91 1233 331 3.08 / 340.46 2 4
6 13 164.48 18 15.02 629 170 3.25 / 340.63 2 4
7 8 0.08 165 15.02 371 919 4.17 / 341.54 2 8
Average= 4.07
(KJ/cycle)

Cycle 82 GMT 11/ 5/2021 20:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 30 14.99 501 225 0.23 / 333.51 2 2
2 7 2002.32 31 14.77 2997 1372 1.60 / 334.88 2 4
3 13 1584.72 18 14.79 2506 667 2.26 / 335.55 2 3
4 13 1019.88 18 14.84 1790 478 2.74 / 336.02 2 6
5 13 480.56 18 14.95 1068 287 3.03 / 336.31 2 4
6 13 123.12 18 15.04 554 150 3.18 / 336.46 2 3
7 8 0.00 165 15.03 367 910 4.09 / 337.37 2 11
Average= 4.06
(KJ/cycle)

Cycle 81 GMT 1/ 5/2021 22:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 29 14.99 492 214 0.21 / 329.41 2 2
2 7 2003.48 31 14.77 2997 1372 1.59 / 330.79 2 4
3 13 1600.92 18 14.78 2523 671 2.26 / 331.46 2 4
4 13 1025.92 18 14.85 1798 481 2.74 / 331.94 2 3
5 13 477.88 18 14.95 1063 286 3.02 / 332.22 2 5
6 13 119.00 18 15.04 565 153 3.18 / 332.38 2 3
7 8 0.08 165 15.03 364 903 4.08 / 333.28 2 8
Average= 4.06
(KJ/cycle)

Cycle 80 GMT 22/ 4/2021 0:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 29 15.00 510 222 0.22 / 325.35 2 2
2 7 2005.48 31 14.78 2989 1369 1.59 / 326.72 2 3
3 13 1485.52 18 14.81 2355 628 2.22 / 327.35 2 5
4 13 1079.80 18 14.84 1848 494 2.71 / 327.84 2 6
5 13 515.36 18 14.94 1116 300 3.01 / 328.14 2 4
6 13 133.92 18 15.04 580 157 3.17 / 328.30 2 3
7 8 0.12 165 15.04 364 903 4.07 / 329.20 2 10
Average= 4.06
(KJ/cycle)

Cycle 79 GMT 12/ 4/2021 2:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 30 15.00 495 223 0.22 / 321.22 2 2
2 7 2004.20 31 14.78 2982 1366 1.59 / 322.58 2 3
3 13 1598.24 18 14.80 2522 672 2.26 / 323.25 2 3
4 13 1037.00 18 14.85 1810 484 2.74 / 323.74 2 4
5 13 600.68 18 14.92 1222 328 3.07 / 324.07 2 4
6 13 179.20 18 15.03 637 172 3.25 / 324.24 2 4
7 8 0.16 165 15.04 358 888 4.13 / 325.13 2 8
Average= 4.06
(KJ/cycle)

Cycle 78 GMT 2/ 4/2021 4: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 30 15.00 501 225 0.23 / 317.20 2 3
2 7 2005.60 31 14.78 3003 1376 1.60 / 318.58 2 4
3 13 1468.76 18 14.81 2365 630 2.23 / 319.21 2 5
4 13 926.28 18 14.87 1657 444 2.68 / 319.65 2 4
5 13 514.36 18 14.95 1114 300 2.98 / 319.95 2 4
6 13 137.12 18 15.05 572 155 3.13 / 320.11 2 3
7 8 -0.04 165 15.04 357 886 4.02 / 320.99 2 9
Average= 4.06
(KJ/cycle)

Cycle 77 GMT 23/ 3/2021 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 30 15.01 511 230 0.23 / 313.08 2 3
2 7 2004.96 31 14.78 2979 1365 1.60 / 314.45 2 3
3 13 1599.76 18 14.79 2516 670 2.26 / 315.11 2 4
4 13 1030.28 18 14.86 1771 474 2.74 / 315.59 2 4
5 13 601.96 18 14.92 1237 332 3.07 / 315.92 2 4
6 13 168.76 18 15.03 631 171 3.24 / 316.09 2 4
7 8 0.08 165 15.05 357 887 4.13 / 316.98 2 11
Average= 4.06
(KJ/cycle)

Cycle 76 GMT 13/ 3/2021 7:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 30 15.00 510 229 0.23 / 308.95 2 2
2 7 2006.20 31 14.78 2986 1368 1.60 / 310.32 2 4
3 13 1573.36 18 14.80 2500 666 2.26 / 310.99 2 4
4 13 1031.36 18 14.86 1796 480 2.74 / 311.47 2 4
5 13 588.64 18 14.93 1211 325 3.07 / 311.79 2 4
6 13 158.56 18 15.05 613 166 3.24 / 311.96 2 3
7 8 0.04 165 15.05 359 891 4.13 / 312.85 2 7
Average= 4.06
(KJ/cycle)

Cycle 75 GMT 3/ 3/2021 9:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 29 15.00 517 225 0.22 / 304.74 2 2
2 7 2006.32 31 14.78 3000 1375 1.60 / 306.11 2 2
3 13 1483.56 18 14.81 2372 632 2.23 / 306.74 2 4
4 13 1068.12 18 14.84 1855 496 2.73 / 307.24 2 4
5 13 502.64 18 14.96 1089 293 3.02 / 307.53 2 4
6 13 129.40 18 15.06 564 153 3.17 / 307.69 2 3
7 8 0.08 165 15.05 362 899 4.07 / 308.59 2 9
8 14 0.08 25 15.03 366 138 4.21 / 308.72 2 10
Average= 4.06
(KJ/cycle)

Cycle 74 GMT 21/ 2/2021 11:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 29 15.01 515 224 0.22 / 300.40 2 2
2 7 2007.64 32 14.78 2999 1418 1.64 / 301.82 2 3
3 13 1594.60 18 14.80 2515 670 2.31 / 302.49 2 5
4 13 1156.04 18 14.83 1970 526 2.84 / 303.02 2 5
5 13 551.36 18 14.95 1164 313 3.15 / 303.33 2 4
6 13 144.24 18 15.06 599 162 3.31 / 303.49 2 3
7 13 33.56 18 15.08 425 115 3.43 / 303.61 2 3
8 8 0.24 165 15.05 364 904 4.33 / 304.51 2 10
Average= 4.06
(KJ/cycle)

Cycle 73 GMT 11/ 2/2021 13: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 29 15.02 499 217 0.22 / 296.20 2 2
2 7 2003.44 31 14.80 2996 1375 1.59 / 297.57 2 3
3 13 1735.80 18 14.78 2689 715 2.31 / 298.29 2 4
4 13 1028.28 18 14.86 1800 481 2.79 / 298.77 2 5
5 13 602.44 18 14.94 1230 331 3.12 / 299.10 2 4
6 13 170.72 18 15.05 630 171 3.29 / 299.27 2 3
7 8 0.16 165 15.06 365 907 4.20 / 300.18 2 8
Average= 4.06
(KJ/cycle)

Cycle 72 GMT 1/ 2/2021 15: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 29 15.03 489 213 0.21 / 291.99 2 2
2 7 2003.40 31 14.80 2987 1370 1.58 / 293.36 2 4
3 13 1729.44 18 14.78 2703 719 2.30 / 294.08 2 4
4 13 1134.40 18 14.85 1929 516 2.82 / 294.59 2 3
5 13 563.64 18 14.96 1173 316 3.13 / 294.91 2 4
6 13 159.64 18 15.06 617 167 3.30 / 295.08 2 4
7 8 0.00 165 15.06 365 907 4.21 / 295.98 2 9
Average= 4.05
(KJ/cycle)

Cycle 71 GMT 22/ 1/2021 16:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.24 29 15.02 518 226 0.23 / 287.88 2 2
2 7 2003.72 31 14.79 2979 1366 1.59 / 289.24 2 4
3 13 1588.80 18 14.80 2524 672 2.26 / 289.92 2 4
4 13 1020.56 18 14.87 1793 480 2.74 / 290.40 2 4
5 13 574.84 18 14.95 1204 324 3.07 / 290.72 2 4
6 13 149.80 18 15.06 601 163 3.23 / 290.88 2 3
7 8 0.12 165 15.07 358 890 4.12 / 291.77 2 10
Average= 4.05
(KJ/cycle)

Cycle 70 GMT 12/ 1/2021 18:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 29 15.03 494 215 0.22 / 283.72 2 2
2 7 2007.44 31 14.79 3006 1378 1.59 / 285.10 2 3
3 13 1603.56 18 14.80 2541 677 2.27 / 285.78 2 3
4 13 1029.96 18 14.87 1799 482 2.75 / 286.26 2 4
5 13 596.16 18 14.95 1224 329 3.08 / 286.59 2 5
6 13 157.08 18 15.06 621 168 3.25 / 286.76 2 3
7 8 0.12 165 15.07 360 895 4.14 / 287.65 2 9
Average= 4.05
(KJ/cycle)

Cycle 69 GMT 2/ 1/2021 20:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.04 29 15.04 528 230 0.23 / 279.60 2 3
2 7 2005.04 31 14.80 2987 1370 1.60 / 280.97 2 4
3 13 1603.20 18 14.80 2532 675 2.28 / 281.64 2 3
4 13 1050.24 18 14.86 1825 488 2.76 / 282.13 2 6
5 13 485.88 18 14.98 1078 291 3.05 / 282.42 2 4
6 13 200.84 18 15.05 677 183 3.24 / 282.61 2 3
7 8 0.16 165 15.07 363 903 4.14 / 283.51 2 8
Average= 4.05
(KJ/cycle)

Cycle 68 GMT 23/12/2020 22:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 29 15.04 502 219 0.22 / 275.37 2 2
2 7 2006.92 31 14.81 2998 1376 1.60 / 276.75 2 3
3 13 1736.36 18 14.79 2705 720 2.32 / 277.47 2 5
4 13 1133.44 18 14.85 1938 518 2.83 / 277.99 2 4
5 13 560.64 18 14.97 1174 316 3.15 / 278.30 2 5
6 13 146.24 18 15.08 601 163 3.31 / 278.47 2 3
7 8 0.08 165 15.08 362 901 4.21 / 279.37 2 9
Average= 4.05
(KJ/cycle)

Cycle 67 GMT 14/12/2020 0:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 29 15.04 496 216 0.22 / 271.21 2 3
2 7 2006.44 31 14.81 3000 1377 1.59 / 272.58 2 3
3 13 1597.76 18 14.81 2532 675 2.27 / 273.26 2 5
4 13 1031.76 18 14.88 1798 482 2.75 / 273.74 2 6
5 13 591.16 18 14.96 1234 332 3.08 / 274.07 2 4
6 13 158.00 18 15.07 626 170 3.25 / 274.24 2 4
7 8 0.08 165 15.08 367 913 4.17 / 275.15 2 10
Average= 4.05
(KJ/cycle)

Cycle 66 GMT 4/12/2020 2:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 29 15.04 498 217 0.22 / 267.08 2 2
2 7 2004.40 31 14.81 2988 1372 1.59 / 268.45 2 3
3 13 1578.92 18 14.81 2503 667 2.26 / 269.12 2 3
4 13 1021.68 18 14.89 1779 477 2.73 / 269.59 2 5
5 13 579.72 18 14.97 1203 324 3.06 / 269.92 2 4
6 13 164.56 18 15.08 623 169 3.23 / 270.09 2 3
7 8 0.08 165 15.09 362 901 4.13 / 270.99 2 11
Average= 4.04
(KJ/cycle)

Cycle 65 GMT 24/11/2020 4:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 29 15.04 501 219 0.22 / 262.95 2 2
2 7 2003.28 31 14.80 3006 1379 1.60 / 264.33 2 3
3 13 1582.40 18 14.82 2524 673 2.27 / 265.01 2 4
4 13 1025.76 18 14.89 1798 482 2.75 / 265.49 2 5
5 13 472.68 18 15.00 1073 290 3.04 / 265.78 2 4
6 13 188.36 18 15.07 668 181 3.22 / 265.96 2 4
7 8 -0.08 165 15.09 362 901 4.13 / 266.86 2 7
Average= 4.04
(KJ/cycle)

Cycle 64 GMT 14/11/2020 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 29 15.06 499 218 0.22 / 258.69 2 2
2 7 2002.48 31 14.81 2988 1372 1.59 / 260.06 2 3
3 13 1583.92 18 14.82 2507 669 2.26 / 260.73 2 5
4 13 1019.60 18 14.89 1795 481 2.74 / 261.21 2 5
5 13 590.92 18 14.97 1213 327 3.07 / 261.54 2 4
6 13 160.36 18 15.09 632 172 3.24 / 261.71 2 3
7 13 38.36 18 15.11 436 119 3.36 / 261.83 2 3
8 8 0.08 165 15.08 364 906 4.26 / 262.74 2 9
Average= 4.04
(KJ/cycle)

Cycle 63 GMT 4/11/2020 8:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 29 15.07 489 214 0.21 / 254.51 2 3
2 7 2003.40 31 14.81 2989 1372 1.59 / 255.88 2 4
3 13 1722.44 18 14.80 2681 714 2.30 / 256.59 2 3
4 13 1126.40 18 14.87 1925 515 2.82 / 257.11 2 5
5 13 558.04 18 14.99 1179 318 3.13 / 257.43 2 4
6 13 143.88 18 15.10 590 160 3.29 / 257.59 2 3
7 8 0.12 165 15.10 356 887 4.18 / 258.47 2 11
Average= 4.04
(KJ/cycle)

Cycle 62 GMT 25/10/2020 10: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 29 15.07 495 216 0.22 / 250.47 2 3
2 7 2003.00 31 14.81 2989 1372 1.59 / 251.84 2 3
3 13 1475.00 18 14.85 2355 629 2.22 / 252.47 2 3
4 13 1066.20 18 14.89 1829 490 2.71 / 252.96 2 3
5 13 490.96 18 15.01 1071 289 3.00 / 253.25 2 4
6 13 119.52 18 15.11 554 151 3.15 / 253.40 2 3
7 8 0.08 165 15.10 357 889 4.04 / 254.29 2 7
Average= 4.04
(KJ/cycle)

Cycle 61 GMT 15/10/2020 11:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 29 15.07 487 213 0.21 / 246.33 2 3
2 7 2003.64 31 14.81 2995 1375 1.59 / 247.71 2 4
3 13 1587.04 18 14.83 2498 667 2.25 / 248.37 2 5
4 13 1036.28 18 14.90 1808 485 2.74 / 248.86 2 6
5 13 603.92 18 14.98 1240 334 3.07 / 249.19 2 4
6 13 167.84 18 15.10 622 169 3.24 / 249.36 2 3
7 8 0.04 165 15.10 359 894 4.14 / 250.26 2 11
Average= 4.04
(KJ/cycle)

Cycle 60 GMT 5/10/2020 13:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 29 15.07 487 213 0.21 / 242.18 2 3
2 7 2008.28 30 14.82 3001 1334 1.55 / 243.51 2 3
3 13 1596.64 17 14.83 2514 634 2.18 / 244.15 2 3
4 13 1164.28 17 14.88 1964 497 2.68 / 244.65 2 5
5 13 601.36 17 14.99 1234 314 2.99 / 244.96 2 4
6 13 196.88 17 15.09 677 174 3.17 / 245.13 2 3
7 13 21.24 17 15.14 406 104 3.27 / 245.24 2 3
8 8 -0.04 165 15.11 353 880 4.15 / 246.12 2 9
Average= 4.03
(KJ/cycle)

Cycle 59 GMT 25/ 9/2020 15:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 29 15.07 511 223 0.22 / 238.04 2 3
2 7 2003.00 30 14.82 2999 1333 1.56 / 239.38 2 3
3 13 1600.40 17 14.83 2518 635 2.19 / 240.01 2 5
4 13 1041.40 17 14.91 1803 457 2.65 / 240.47 2 5
5 13 620.52 17 14.99 1248 318 2.97 / 240.79 2 4
6 13 199.52 17 15.10 675 173 3.14 / 240.96 2 3
7 13 21.56 17 15.14 418 108 3.25 / 241.07 2 3
8 8 0.08 165 15.11 361 900 4.15 / 241.97 2 11
Average= 4.03
(KJ/cycle)

Cycle 58 GMT 15/ 9/2020 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 29 15.08 490 214 0.21 / 233.75 2 3
2 7 2005.28 30 14.83 2998 1334 1.55 / 235.08 2 3
3 13 1742.72 17 14.81 2702 680 2.23 / 235.76 2 6
4 13 1158.68 17 14.88 1957 495 2.72 / 236.26 2 5
5 13 722.92 17 14.96 1398 356 3.08 / 236.61 2 5
6 13 273.44 17 15.07 782 200 3.28 / 236.81 2 4
7 13 29.80 17 15.14 427 110 3.39 / 236.92 2 3
8 8 0.04 165 15.11 360 898 4.29 / 237.82 2 9
Average= 4.03
(KJ/cycle)

Cycle 57 GMT 5/ 9/2020 19: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 29 15.08 481 210 0.21 / 229.51 2 3
2 7 2003.84 31 14.83 3002 1380 1.59 / 230.89 2 3
3 13 1717.48 17 14.82 2668 672 2.26 / 231.56 2 3
4 13 1130.76 17 14.89 1924 487 2.75 / 232.05 2 3
5 13 580.04 17 15.00 1200 306 3.06 / 232.35 2 4
6 13 175.84 17 15.11 641 165 3.22 / 232.52 2 4
7 13 37.64 17 15.14 436 112 3.33 / 232.63 2 3
8 8 0.08 165 15.11 362 903 4.24 / 233.53 2 10
Average= 4.03
(KJ/cycle)

Cycle 56 GMT 26/ 8/2020 20:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 29 15.09 502 220 0.22 / 225.36 2 3
2 7 2002.36 30 14.84 2992 1332 1.55 / 226.69 2 3
3 13 1596.80 17 14.83 2535 639 2.19 / 227.33 2 5
4 13 1049.76 17 14.91 1824 462 2.65 / 227.80 2 4
5 13 629.04 17 14.99 1268 323 2.98 / 228.12 2 4
6 13 213.44 17 15.10 698 179 3.16 / 228.30 2 4
7 13 23.24 17 15.15 418 108 3.26 / 228.41 2 3
8 8 0.12 165 15.12 358 893 4.16 / 229.30 2 10
Average= 4.02
(KJ/cycle)

Cycle 55 GMT 16/ 8/2020 22:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 29 15.09 481 210 0.21 / 221.12 2 3
2 7 2003.48 30 14.84 2983 1328 1.54 / 222.44 2 3
3 13 1595.28 17 14.85 2524 637 2.18 / 223.08 2 3
4 13 1172.08 17 14.89 1981 501 2.68 / 223.58 2 5
5 13 728.04 17 14.97 1408 358 3.04 / 223.94 2 4
6 13 278.88 17 15.08 799 205 3.24 / 224.14 2 4
7 13 28.16 17 15.15 413 106 3.35 / 224.25 2 3
8 8 -0.04 165 15.12 357 891 4.24 / 225.14 2 12
Average= 4.02
(KJ/cycle)

Cycle 54 GMT 7/ 8/2020 0:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 29 15.08 495 216 0.22 / 216.97 2 3
2 7 2003.92 30 14.85 2986 1330 1.55 / 218.30 2 3
3 13 1586.80 17 14.85 2511 634 2.18 / 218.93 2 4
4 13 1035.36 17 14.93 1801 457 2.64 / 219.39 2 6
5 13 617.56 17 15.00 1262 322 2.96 / 219.71 2 4
6 13 198.36 17 15.11 680 175 3.13 / 219.88 2 4
7 13 20.52 17 15.16 412 106 3.24 / 219.99 2 3
8 8 0.08 165 15.12 367 916 4.16 / 220.90 2 10
Average= 4.02
(KJ/cycle)

Cycle 53 GMT 28/ 7/2020 2:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.20 29 15.09 516 226 0.23 / 212.72 2 3
2 7 2002.64 30 14.84 3007 1339 1.56 / 214.06 2 3
3 13 1584.64 17 14.85 2520 636 2.20 / 214.70 2 4
4 13 1155.40 17 14.90 1966 498 2.70 / 215.19 2 6
5 13 704.48 17 14.98 1376 350 3.05 / 215.54 2 5
6 13 254.36 17 15.09 767 197 3.25 / 215.74 2 4
7 13 28.48 17 15.16 425 110 3.36 / 215.85 2 3
8 8 0.00 165 15.12 360 898 4.25 / 216.75 2 8
Average= 4.01
(KJ/cycle)

Cycle 52 GMT 18/ 7/2020 4:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 29 15.10 519 227 0.23 / 208.53 2 3
2 7 2004.16 30 14.84 2997 1334 1.56 / 209.86 2 4
3 13 1591.08 17 14.85 2520 636 2.20 / 210.50 2 4
4 13 1051.88 17 14.93 1832 465 2.66 / 210.96 2 6
5 13 624.80 17 15.00 1282 327 2.99 / 211.29 2 4
6 13 203.72 17 15.11 692 178 3.17 / 211.47 2 4
7 13 20.12 17 15.16 415 107 3.27 / 211.58 2 3
8 8 0.08 165 15.13 368 919 4.19 / 212.50 2 13
Average= 4.01
(KJ/cycle)

Cycle 51 GMT 8/ 7/2020 6:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 29 15.10 512 224 0.22 / 204.30 2 3
2 7 2001.84 30 14.85 3004 1338 1.56 / 205.64 2 3
3 13 1597.80 17 14.85 2534 640 2.20 / 206.28 2 5
4 13 1163.52 17 14.90 1978 501 2.70 / 206.78 2 4
5 13 605.68 17 15.01 1246 318 3.02 / 207.10 2 4
6 13 201.36 17 15.12 683 176 3.20 / 207.27 2 4
7 8 0.12 165 15.14 357 892 4.09 / 208.16 2 10
8 14 0.12 25 15.12 367 139 4.23 / 208.30 3 8
Average= 4.01
(KJ/cycle)

Cycle 50 GMT 28/ 6/2020 7:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 29 15.11 512 224 0.22 / 200.09 2 3
2 7 2009.16 31 14.83 3007 1382 1.61 / 201.48 2 4
3 13 1605.40 17 14.85 2539 641 2.25 / 202.12 2 4
4 13 1169.20 17 14.90 1994 505 2.75 / 202.62 2 4
5 13 714.60 17 14.98 1392 354 3.11 / 202.98 2 4
6 13 261.40 17 15.10 769 197 3.30 / 203.17 2 4
7 8 0.04 165 15.14 361 902 4.21 / 204.07 2 9
Average= 4.00
(KJ/cycle)

Cycle 49 GMT 18/ 6/2020 9:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 29 15.10 505 221 0.22 / 196.02 2 2
2 7 2004.96 30 14.85 2999 1336 1.56 / 197.36 2 4
3 13 1613.52 17 14.85 2562 647 2.20 / 198.01 2 4
4 13 1048.00 17 14.93 1830 464 2.67 / 198.47 2 4
5 13 619.72 17 15.01 1267 323 2.99 / 198.79 2 4
6 13 203.08 17 15.12 688 177 3.17 / 198.97 2 4
7 8 0.16 165 15.15 359 897 4.07 / 199.87 2 9
Average= 4.00
(KJ/cycle)

Cycle 48 GMT 8/ 6/2020 11:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 29 15.11 517 227 0.23 / 191.96 2 3
2 7 2003.80 30 14.84 2998 1335 1.56 / 193.29 2 4
3 13 1589.36 17 14.86 2501 632 2.19 / 193.92 2 3
4 13 1050.32 17 14.93 1849 469 2.66 / 194.39 2 5
5 13 628.16 17 15.02 1273 325 2.99 / 194.72 2 4
6 13 196.28 17 15.13 671 173 3.16 / 194.89 2 4
7 8 0.16 165 15.14 365 912 4.07 / 195.80 2 6
Average= 4.00
(KJ/cycle)

Cycle 47 GMT 29/ 5/2020 13: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 29 15.10 512 224 0.22 / 187.87 2 3
2 7 2007.00 30 14.84 3003 1337 1.56 / 189.21 2 4
3 13 1602.72 17 14.86 2525 638 2.20 / 189.85 2 4
4 13 1036.28 17 14.94 1832 465 2.66 / 190.31 2 5
5 13 608.32 17 15.02 1260 322 2.99 / 190.63 2 4
6 13 182.80 17 15.13 666 171 3.16 / 190.80 2 4
7 8 -0.04 165 15.14 371 927 4.08 / 191.73 2 9
Average= 3.99
(KJ/cycle)

Cycle 46 GMT 19/ 5/2020 14:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 29 15.11 516 226 0.23 / 183.80 2 3
2 7 2003.92 30 14.84 2986 1329 1.56 / 185.13 2 3
3 13 1594.48 17 14.86 2536 641 2.20 / 185.77 2 3
4 13 1039.12 17 14.94 1810 460 2.66 / 186.23 2 4
5 13 606.96 17 15.02 1250 319 2.97 / 186.55 2 4
6 13 185.84 17 15.14 651 168 3.14 / 186.72 2 3
7 8 0.12 165 15.15 371 927 4.07 / 187.65 2 9
Average= 3.99
(KJ/cycle)

Cycle 45 GMT 9/ 5/2020 16:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.24 29 15.11 526 230 0.23 / 179.74 2 3
2 7 2002.48 30 14.85 3003 1338 1.57 / 181.07 2 4
3 13 1580.52 17 14.86 2524 638 2.21 / 181.71 2 3
4 13 1041.32 17 14.94 1827 464 2.67 / 182.18 2 6
5 13 618.00 17 15.03 1269 324 2.99 / 182.50 2 4
6 13 198.16 17 15.13 678 174 3.17 / 182.67 2 4
7 8 0.12 165 15.15 361 902 4.07 / 183.58 2 9
Average= 3.99
(KJ/cycle)

Cycle 44 GMT 29/ 4/2020 18:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 29 15.11 538 236 0.24 / 175.67 2 3
2 7 2003.80 30 14.86 2976 1327 1.56 / 177.00 2 3
3 13 1594.44 17 14.86 2517 636 2.20 / 177.64 2 4
4 13 1039.16 17 14.95 1799 457 2.66 / 178.09 2 5
5 13 599.80 17 15.03 1242 317 2.97 / 178.41 2 5
6 13 184.68 17 15.14 662 170 3.14 / 178.58 2 4
7 8 0.12 165 15.15 370 925 4.07 / 179.51 2 11
Average= 3.99
(KJ/cycle)

Cycle 43 GMT 19/ 4/2020 20: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 29 15.12 516 226 0.23 / 171.53 2 3
2 7 2004.04 30 14.85 2981 1328 1.55 / 172.85 2 4
3 13 1608.16 17 14.87 2551 645 2.20 / 173.50 2 3
4 13 1186.16 17 14.92 2002 508 2.71 / 174.01 2 4
5 13 612.76 17 15.04 1239 317 3.02 / 174.32 2 4
6 13 197.32 17 15.14 687 177 3.20 / 174.50 2 4
7 8 0.08 165 15.16 375 938 4.14 / 175.44 2 10
Average= 3.99
(KJ/cycle)

Cycle 42 GMT 9/ 4/2020 21:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 29 15.12 521 228 0.23 / 167.42 2 3
2 7 2003.40 30 14.85 2993 1333 1.56 / 168.76 2 3
3 13 1605.32 17 14.86 2541 642 2.20 / 169.40 2 3
4 13 1058.12 17 14.95 1852 471 2.67 / 169.87 2 5
5 13 636.72 17 15.03 1290 330 3.00 / 170.20 2 5
6 13 209.00 17 15.13 701 180 3.18 / 170.38 2 4
7 8 0.04 165 15.16 367 918 4.10 / 171.30 2 9
Average= 3.98
(KJ/cycle)

Cycle 41 GMT 30/ 3/2020 23:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 29 15.12 518 227 0.23 / 163.33 2 3
2 7 2008.12 30 14.87 2996 1337 1.56 / 164.67 2 4
3 13 1606.56 17 14.87 2548 644 2.21 / 165.31 2 4
4 13 1060.76 17 14.95 1844 469 2.68 / 165.78 2 4
5 13 636.00 17 15.03 1287 329 3.01 / 166.11 2 4
6 13 213.92 17 15.14 705 181 3.19 / 166.29 2 4
7 8 0.16 165 15.16 363 908 4.09 / 167.20 2 11
Average= 3.98
(KJ/cycle)

Cycle 40 GMT 21/ 3/2020 0:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 29 15.13 540 237 0.24 / 159.29 2 2
2 7 2003.20 30 14.87 3000 1338 1.58 / 160.63 2 3
3 13 1577.88 17 14.88 2509 635 2.21 / 161.27 2 4
4 13 1026.40 17 14.97 1793 456 2.67 / 161.72 2 5
5 13 506.36 17 15.08 1091 280 2.95 / 162.00 2 4
6 13 227.96 17 15.14 722 186 3.13 / 162.19 2 4
7 8 -0.08 165 15.16 365 913 4.04 / 163.10 2 9
Average= 3.98
(KJ/cycle)

Cycle 39 GMT 11/ 3/2020 2:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 29 15.12 533 234 0.23 / 155.14 2 3
2 7 2002.16 30 14.87 3001 1339 1.57 / 156.48 2 3
3 13 1738.56 17 14.86 2718 687 2.26 / 157.16 2 3
4 13 1141.88 17 14.94 1955 497 2.76 / 157.66 2 4
5 13 578.72 17 15.06 1208 309 3.06 / 157.97 2 5
6 13 176.88 17 15.16 652 168 3.23 / 158.14 2 3
7 8 -0.08 165 15.17 368 921 4.15 / 159.06 2 9
Average= 3.98
(KJ/cycle)

Cycle 38 GMT 1/ 3/2020 4:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.24 29 15.13 535 235 0.23 / 150.96 2 2
2 7 2002.32 31 14.87 3003 1384 1.62 / 152.34 2 4
3 13 1573.08 17 14.88 2508 634 2.25 / 152.98 2 5
4 13 1142.16 17 14.94 1957 497 2.75 / 153.48 2 6
5 13 568.36 17 15.06 1202 308 3.06 / 153.78 2 4
6 13 285.24 17 15.12 808 208 3.27 / 153.99 2 4
7 8 0.16 165 15.17 364 911 4.18 / 154.90 2 8
Average= 3.97
(KJ/cycle)

Cycle 37 GMT 20/ 2/2020 6: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 29 15.13 517 227 0.23 / 146.84 2 2
2 7 2006.48 30 14.88 3004 1341 1.57 / 148.18 2 3
3 13 1600.64 17 14.88 2541 643 2.21 / 148.82 2 3
4 13 1157.64 17 14.94 1974 501 2.71 / 149.32 2 4
5 13 586.08 17 15.06 1227 314 3.03 / 149.64 2 4
6 13 185.44 17 15.16 665 171 3.20 / 149.81 2 4
7 8 0.00 165 15.18 367 919 4.12 / 150.73 2 9
Average= 3.97
(KJ/cycle)

Cycle 36 GMT 10/ 2/2020 7:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 29 15.13 522 229 0.23 / 142.60 2 3
2 7 2007.84 30 14.88 2998 1338 1.57 / 143.94 2 3
3 13 1604.64 17 14.88 2557 647 2.21 / 144.58 2 5
4 13 1175.44 17 14.94 2000 508 2.72 / 145.09 2 5
5 13 596.00 17 15.06 1235 316 3.04 / 145.41 2 5
6 13 192.76 17 15.16 672 173 3.21 / 145.58 2 3
7 13 22.32 17 15.21 419 108 3.32 / 145.69 2 3
8 8 0.08 165 15.17 368 921 4.24 / 146.61 2 10
Average= 3.96
(KJ/cycle)

Cycle 35 GMT 31/ 1/2020 9:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 29 15.14 526 231 0.23 / 138.51 2 3
2 7 2005.28 30 14.87 3003 1340 1.57 / 139.85 2 4
3 13 1463.00 17 14.92 2350 596 2.17 / 140.45 2 4
4 13 1181.44 17 14.94 1987 505 2.67 / 140.96 2 5
5 13 583.88 17 15.07 1218 312 2.98 / 141.27 2 4
6 13 170.56 17 15.17 647 167 3.15 / 141.43 2 3
7 8 0.12 165 15.18 373 934 4.08 / 142.37 2 9
Average= 3.95
(KJ/cycle)

Cycle 34 GMT 21/ 1/2020 11:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 29 15.15 519 228 0.23 / 134.39 2 3
2 7 2004.12 30 14.87 3025 1349 1.58 / 135.74 2 3
3 13 1598.84 17 14.88 2554 646 2.22 / 136.38 2 5
4 13 1170.08 17 14.94 1985 504 2.73 / 136.89 2 5
5 13 579.24 17 15.07 1217 312 3.04 / 137.20 2 4
6 13 176.92 17 15.17 657 169 3.21 / 137.37 2 4
7 8 -0.04 165 15.18 366 917 4.13 / 138.28 2 9
Average= 3.95
(KJ/cycle)

Cycle 33 GMT 11/ 1/2020 13:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 29 15.15 504 221 0.22 / 130.25 2 3
2 7 2001.04 31 14.88 3006 1387 1.61 / 131.64 2 3
3 13 1577.56 17 14.90 2509 636 2.24 / 132.28 2 4
4 13 1148.08 17 14.96 1950 496 2.74 / 132.77 2 4
5 13 566.52 17 15.08 1197 307 3.05 / 133.08 2 5
6 13 172.44 17 15.18 646 167 3.21 / 133.25 2 4
7 8 0.04 165 15.19 364 912 4.13 / 134.16 2 9
Average= 3.95
(KJ/cycle)

Cycle 32 GMT 1/ 1/2020 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 29 15.15 498 219 0.22 / 126.01 2 2
2 7 2007.64 30 14.88 2992 1336 1.55 / 127.35 2 4
3 13 1736.80 17 14.87 2713 686 2.24 / 128.03 2 3
4 13 1015.52 17 14.99 1803 459 2.70 / 128.49 2 5
5 13 605.48 17 15.07 1251 320 3.02 / 128.81 2 4
6 13 194.08 17 15.17 683 176 3.20 / 128.99 2 3
7 13 50.72 17 15.21 465 120 3.32 / 129.11 2 3
8 8 0.16 165 15.18 368 922 4.24 / 130.03 2 9
Average= 3.94
(KJ/cycle)

Cycle 31 GMT 22/12/2019 16:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 29 15.15 532 234 0.23 / 121.90 2 3
2 7 2002.28 30 14.89 3011 1345 1.58 / 123.25 2 3
3 13 1602.32 17 14.90 2551 646 2.22 / 123.90 2 4
4 13 1046.28 17 14.99 1838 468 2.69 / 124.36 2 4
5 13 631.68 17 15.06 1288 330 3.02 / 124.69 2 4
6 13 204.88 17 15.17 702 181 3.20 / 124.87 2 4
7 8 0.12 165 15.19 367 920 4.12 / 125.79 2 12
Average= 3.93
(KJ/cycle)

Cycle 30 GMT 12/12/2019 18: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 29 15.15 534 235 0.23 / 117.79 2 3
2 7 2008.00 31 14.88 3013 1390 1.62 / 119.18 2 4
3 13 1478.00 17 14.92 2396 608 2.23 / 119.79 2 5
4 13 1056.68 17 14.98 1858 473 2.71 / 120.26 2 5
5 13 503.08 17 15.10 1120 288 2.99 / 120.55 2 4
6 13 223.24 17 15.16 733 189 3.18 / 120.74 2 3
7 8 0.24 165 15.19 372 932 4.11 / 121.67 2 9
Average= 3.92
(KJ/cycle)

Cycle 29 GMT 2/12/2019 19:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 29 15.16 518 228 0.23 / 113.69 2 3
2 7 2005.64 30 14.88 3018 1347 1.57 / 115.04 2 3
3 13 1581.00 17 14.91 2534 642 2.22 / 115.68 2 3
4 13 1010.16 17 15.00 1796 458 2.68 / 116.14 2 6
5 13 582.96 17 15.08 1221 313 2.99 / 116.45 2 4
6 13 167.12 17 15.19 651 168 3.16 / 116.62 2 3
7 8 -0.04 165 15.20 373 935 4.09 / 117.56 2 9
Average= 3.92
(KJ/cycle)

Cycle 28 GMT 22/11/2019 21:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 29 15.16 498 219 0.22 / 109.53 2 3
2 7 2003.20 30 14.90 3012 1346 1.57 / 110.88 2 3
3 13 1732.48 17 14.88 2718 688 2.25 / 111.57 2 5
4 13 1027.96 17 14.99 1825 465 2.72 / 112.03 2 4
5 13 611.80 17 15.07 1269 325 3.04 / 112.36 2 4
6 13 199.24 17 15.18 690 178 3.22 / 112.53 2 3
7 8 0.16 165 15.20 371 930 4.15 / 113.46 2 12
Average= 3.91
(KJ/cycle)

Cycle 27 GMT 12/11/2019 23: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.44 28 15.17 534 227 0.23 / 105.44 2 3
2 7 2007.20 30 14.89 3008 1344 1.57 / 106.79 2 4
3 13 1595.28 17 14.91 2540 644 2.21 / 107.43 2 4
4 13 1036.36 17 15.00 1821 464 2.68 / 107.90 2 4
5 13 605.00 17 15.08 1255 322 3.00 / 108.22 2 4
6 13 176.80 17 15.19 657 170 3.17 / 108.39 2 4
7 8 0.04 165 15.20 369 925 4.10 / 109.31 2 10
Average= 3.90
(KJ/cycle)

Cycle 26 GMT 3/11/2019 0:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.32 28 15.17 520 221 0.22 / 101.36 2 3
2 7 2006.36 30 14.89 3023 1350 1.57 / 102.71 2 3
3 13 1597.84 17 14.91 2541 644 2.22 / 103.35 2 3
4 13 1032.40 17 15.00 1821 464 2.68 / 103.82 2 5
5 13 501.12 17 15.11 1110 285 2.96 / 104.10 2 5
6 13 221.16 17 15.18 727 188 3.15 / 104.29 2 4
7 8 0.08 165 15.21 370 929 4.08 / 105.22 2 11
Average= 3.90
(KJ/cycle)

Cycle 25 GMT 24/10/2019 2:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 28 15.17 512 217 0.22 / 97.31 2 3
2 7 2007.60 30 14.90 2983 1333 1.55 / 98.64 2 3
3 13 1574.44 17 14.92 2515 638 2.19 / 99.28 2 5
4 13 1011.08 17 15.02 1770 452 2.64 / 99.73 2 6
5 13 586.24 17 15.09 1224 314 2.95 / 100.04 2 4
6 13 174.04 17 15.20 650 168 3.12 / 100.21 2 3
7 8 0.16 165 15.21 369 926 4.05 / 101.14 2 7
Average= 3.89
(KJ/cycle)

Cycle 24 GMT 14/10/2019 4: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 28 15.17 522 222 0.22 / 93.05 2 3
2 7 2002.04 30 14.91 3005 1344 1.57 / 94.39 2 4
3 13 1605.28 17 14.92 2547 646 2.21 / 95.04 2 6
4 13 1166.36 17 14.98 1984 505 2.72 / 95.55 2 7
5 13 593.48 17 15.10 1236 317 3.03 / 95.86 2 4
6 13 188.32 17 15.19 678 175 3.21 / 96.04 2 4
7 13 41.48 17 15.24 452 117 3.33 / 96.15 2 3
8 8 -0.04 165 15.20 372 933 4.26 / 97.09 2 9
Average= 3.88
(KJ/cycle)

Cycle 23 GMT 4/10/2019 5:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 28 15.18 492 209 0.21 / 88.84 2 3
2 7 2003.36 30 14.90 2988 1336 1.54 / 90.17 2 4
3 13 1600.04 17 14.92 2549 647 2.19 / 90.82 2 3
4 13 1033.60 17 15.01 1813 463 2.65 / 91.28 2 4
5 13 605.52 17 15.09 1257 322 2.98 / 91.60 2 4
6 13 187.24 17 15.20 676 175 3.15 / 91.78 2 4
7 13 39.44 17 15.24 452 117 3.27 / 91.90 2 3
8 8 0.08 165 15.20 372 933 4.20 / 92.83 2 10
Average= 3.87
(KJ/cycle)

Cycle 22 GMT 24/ 9/2019 7: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 28 15.17 498 212 0.21 / 84.61 2 3
2 7 2004.12 30 14.90 3010 1345 1.56 / 85.95 2 4
3 13 1593.04 17 14.92 2554 648 2.20 / 86.60 2 5
4 13 1151.56 17 14.98 1970 502 2.71 / 87.10 2 5
5 13 576.48 17 15.10 1204 309 3.02 / 87.41 2 5
6 13 165.08 17 15.21 640 165 3.18 / 87.58 2 4
7 13 33.84 17 15.24 443 115 3.30 / 87.69 2 3
8 8 0.16 165 15.21 373 936 4.23 / 88.63 2 12
Average= 3.85
(KJ/cycle)

Cycle 21 GMT 14/ 9/2019 8:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 28 15.18 527 224 0.22 / 80.47 2 3
2 7 2010.68 30 14.90 3006 1344 1.57 / 81.81 2 3
3 13 1486.36 16 14.96 2411 577 2.14 / 82.39 2 4
4 13 1074.68 16 15.02 1871 450 2.59 / 82.84 2 6
5 13 641.48 16 15.09 1306 315 2.91 / 83.15 2 4
6 13 224.00 16 15.20 732 178 3.09 / 83.33 2 4
7 13 25.76 16 15.25 437 107 3.19 / 83.44 2 3
8 8 0.08 165 15.21 382 959 4.15 / 84.40 2 12
Average= 3.84
(KJ/cycle)

Cycle 20 GMT 4/ 9/2019 10: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 28 15.18 524 223 0.22 / 76.28 2 3
2 7 2003.08 30 14.91 2990 1337 1.56 / 77.62 2 3
3 13 1601.04 16 14.94 2540 607 2.17 / 78.23 2 3
4 13 1159.96 16 15.00 1983 476 2.64 / 78.70 2 4
5 13 590.84 16 15.11 1244 301 2.94 / 79.00 2 4
6 13 202.20 16 15.21 701 171 3.11 / 79.17 2 4
7 13 25.52 16 15.25 441 108 3.22 / 79.28 2 3
8 8 0.08 165 15.22 383 962 4.18 / 80.24 2 11
Average= 3.82
(KJ/cycle)

Cycle 19 GMT 25/ 8/2019 11:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 28 15.18 523 222 0.22 / 72.12 2 2
2 7 2003.68 30 14.92 2994 1340 1.56 / 73.46 2 3
3 13 1598.92 16 14.94 2552 610 2.17 / 74.07 2 3
4 13 1036.80 16 15.03 1832 441 2.61 / 74.51 2 6
5 13 615.20 16 15.11 1255 303 2.92 / 74.81 2 5
6 13 206.40 16 15.21 717 174 3.09 / 74.99 2 3
7 13 22.84 16 15.25 432 105 3.20 / 75.09 2 3
8 8 -0.04 165 15.22 385 967 4.16 / 76.06 2 10
Average= 3.80
(KJ/cycle)

Cycle 18 GMT 15/ 8/2019 12:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 28 15.19 518 220 0.22 / 67.91 2 3
2 7 2002.80 30 14.92 2992 1339 1.56 / 69.25 2 3
3 13 1591.36 16 14.95 2540 608 2.17 / 69.86 2 5
4 13 1152.56 16 15.00 1995 479 2.65 / 70.34 2 4
5 13 581.20 16 15.12 1230 298 2.94 / 70.64 2 4
6 13 190.84 16 15.22 686 167 3.11 / 70.81 2 4
7 13 40.92 16 15.25 463 113 3.22 / 70.92 2 3
8 8 0.04 165 15.22 389 977 4.20 / 71.89 2 11
Average= 3.78
(KJ/cycle)

Cycle 17 GMT 5/ 8/2019 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 28 15.18 539 229 0.23 / 63.68 2 3
2 7 2006.88 30 14.93 3016 1351 1.58 / 65.03 2 3
3 13 1603.40 16 14.95 2579 617 2.20 / 65.65 2 3
4 13 1056.12 16 15.03 1859 447 2.64 / 66.09 2 4
5 13 649.24 16 15.10 1328 321 2.96 / 66.41 2 5
6 13 236.32 16 15.20 761 185 3.15 / 66.60 2 3
7 13 23.84 16 15.26 441 108 3.26 / 66.71 2 3
8 8 0.08 165 15.22 393 987 4.24 / 67.69 2 11
Average= 3.76
(KJ/cycle)

Cycle 16 GMT 26/ 7/2019 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 28 15.19 565 240 0.24 / 59.48 2 3
2 7 2007.00 30 14.92 3017 1350 1.59 / 60.83 2 3
3 13 1594.68 16 14.95 2576 616 2.21 / 61.45 2 4
4 13 1027.52 16 15.04 1821 438 2.65 / 61.88 2 4
5 13 617.20 16 15.12 1277 309 2.95 / 62.19 2 5
6 13 206.20 16 15.22 718 175 3.13 / 62.37 2 3
7 13 21.08 16 15.26 437 107 3.24 / 62.48 2 3
8 8 0.00 165 15.23 388 975 4.21 / 63.45 2 11
Average= 3.73
(KJ/cycle)

Cycle 15 GMT 16/ 7/2019 17: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 28 15.19 553 235 0.24 / 55.32 2 3
2 7 2004.48 30 14.93 3004 1345 1.58 / 56.67 2 5
3 13 1592.00 16 14.96 2553 611 2.19 / 57.28 2 4
4 13 1149.44 16 15.01 1986 477 2.67 / 57.76 2 6
5 13 589.56 16 15.13 1251 303 2.97 / 58.06 2 5
6 13 189.00 16 15.22 692 169 3.14 / 58.23 2 4
7 8 0.08 165 15.23 402 1010 4.15 / 59.24 2 12
Average= 3.70
(KJ/cycle)

Cycle 14 GMT 6/ 7/2019 18:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 28 15.20 541 230 0.23 / 51.13 2 3
2 7 2005.80 31 14.93 3004 1390 1.62 / 52.52 2 4
3 13 1579.56 16 14.97 2524 605 2.23 / 53.12 2 4
4 13 1040.20 16 15.04 1844 444 2.67 / 53.57 2 6
5 13 613.68 16 15.12 1280 310 2.98 / 53.88 2 4
6 13 205.92 16 15.22 719 175 3.15 / 54.05 2 4
7 8 0.08 165 15.23 413 1038 4.19 / 55.09 2 10
Average= 3.67
(KJ/cycle)

Cycle 13 GMT 26/ 6/2019 20:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 28 15.21 565 241 0.24 / 46.93 2 3
2 7 2004.16 31 14.92 3032 1402 1.64 / 48.33 2 3
3 13 1593.72 16 14.96 2568 615 2.26 / 48.95 2 5
4 13 1042.76 16 15.04 1854 446 2.70 / 49.40 2 6
5 13 620.32 16 15.12 1303 315 3.02 / 49.71 2 4
6 13 209.12 16 15.22 733 179 3.20 / 49.89 2 4
7 8 0.04 165 15.24 401 1008 4.21 / 50.90 2 6
Average= 3.64
(KJ/cycle)

Cycle 12 GMT 16/ 6/2019 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 28 15.22 475 202 0.20 / 43.05 2 3
2 7 2003.64 30 14.95 2963 1329 1.53 / 44.38 2 3
3 13 1584.96 16 14.99 2480 595 2.13 / 44.98 2 5
4 13 1015.28 16 15.07 1742 420 2.55 / 45.40 2 4
5 13 584.72 16 15.15 1172 284 2.83 / 45.68 2 4
6 13 295.64 16 15.21 779 190 3.02 / 45.87 2 3
7 8 0.08 165 15.27 326 821 3.84 / 46.69 2 10
Average= 3.59
(KJ/cycle)

Cycle 11 GMT 6/ 6/2019 23: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.12 28 15.23 491 209 0.21 / 38.86 2 3
2 7 2007.04 30 14.95 2969 1332 1.54 / 40.19 2 3
3 13 1590.92 16 14.99 2490 597 2.14 / 40.79 2 4
4 13 1028.16 16 15.07 1762 425 2.56 / 41.21 2 6
5 13 609.72 16 15.14 1211 293 2.86 / 41.51 2 5
6 13 202.08 16 15.25 643 157 3.01 / 41.66 2 3
7 8 0.08 165 15.27 326 821 3.83 / 42.48 2 7
8 14 0.08 75 15.24 321 367 4.20 / 42.85 2 15
Average= 3.57
(KJ/cycle)

Cycle 10 GMT 28/ 5/2019 0: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 27 15.23 496 204 0.20 / 35.02 2 3
2 7 2003.00 30 14.95 2960 1328 1.53 / 36.35 2 3
3 13 1583.96 16 14.99 2487 596 2.13 / 36.95 2 4
4 13 1020.84 16 15.08 1757 424 2.55 / 37.37 2 5
5 13 607.60 16 15.15 1204 292 2.84 / 37.66 2 5
6 13 198.68 16 15.25 641 156 3.00 / 37.82 2 4
7 8 0.16 165 15.27 329 829 3.83 / 38.65 2 10
Average= 3.51
(KJ/cycle)

Cycle 9 GMT 18/ 5/2019 1:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 27 15.24 483 199 0.20 / 31.15 2 3
2 7 2002.36 30 14.96 2962 1329 1.53 / 32.48 2 3
3 13 1587.64 16 15.00 2483 596 2.12 / 33.07 2 4
4 13 1033.52 16 15.08 1773 428 2.55 / 33.50 2 4
5 13 631.48 16 15.15 1239 300 2.85 / 33.80 2 4
6 13 217.44 16 15.25 673 164 3.02 / 33.97 2 4
7 8 0.04 165 15.27 339 854 3.87 / 34.82 2 10
Average= 3.48
(KJ/cycle)

Cycle 8 GMT 8/ 5/2019 3: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 27 15.23 477 196 0.20 / 27.36 2 2
2 7 2002.12 30 14.97 2963 1331 1.53 / 28.69 2 4
3 13 1584.72 16 15.00 2478 595 2.12 / 29.28 2 4
4 13 926.76 16 15.10 1633 395 2.52 / 29.68 2 4
5 13 545.32 16 15.17 1123 273 2.79 / 29.95 2 4
6 13 262.16 16 15.23 730 178 2.97 / 30.13 2 4
7 8 0.16 165 15.27 327 824 3.79 / 30.95 2 9
Average= 3.44
(KJ/cycle)

Cycle 7 GMT 28/ 4/2019 4:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 27 15.24 484 199 0.20 / 23.53 2 3
2 7 2003.04 30 14.97 2970 1334 1.53 / 24.86 2 4
3 13 1587.44 16 15.00 2476 594 2.13 / 25.46 2 4
4 13 1025.12 16 15.08 1755 423 2.55 / 25.88 2 4
5 13 606.48 16 15.16 1207 293 2.84 / 26.18 2 4
6 13 201.40 16 15.25 645 157 3.00 / 26.33 2 4
7 8 -0.12 165 15.27 328 826 3.83 / 27.16 2 8
Average= 3.39
(KJ/cycle)

Cycle 6 GMT 18/ 4/2019 5:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 26 15.25 479 190 0.19 / 19.55 2 3
2 10 1033.84 2 15.18 1817 55 0.25 / 19.60 2 3
3 7 2002.72 38 14.92 2950 1673 1.92 / 21.28 2 5
4 13 1380.64 18 15.02 2207 597 2.51 / 21.87 2 5
5 13 785.88 18 15.12 1442 392 2.91 / 22.26 2 5
6 13 336.00 18 15.22 839 230 3.14 / 22.49 2 4
7 8 0.00 165 15.28 332 837 3.97 / 23.33 2 8
Average= 3.33
(KJ/cycle)

Cycle 5 GMT 8/ 4/2019 7:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 23 15.25 477 167 0.17 / 15.60 2 3
2 10 1024.32 3 15.18 1787 81 0.25 / 15.68 2 4
3 3 1019.72 1 15.27 1796 27 0.28 / 15.71 2 4
4 7 2003.20 38 14.92 2955 1675 1.95 / 17.38 2 3
5 13 1264.20 18 15.05 2062 559 2.51 / 17.94 2 4
6 13 707.04 18 15.15 1335 364 2.87 / 18.30 2 5
7 13 283.08 18 15.24 764 210 3.08 / 18.51 2 5
8 8 0.04 165 15.28 335 845 3.93 / 19.36 2 6
Average= 3.23
(KJ/cycle)

Cycle 4 GMT 29/ 3/2019 8:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 26 15.24 489 194 0.19 / 12.22 2 3
2 7 1519.80 38 15.06 2333 1335 1.53 / 13.55 2 3
3 13 1124.56 18 15.10 1866 507 2.04 / 14.06 2 6
4 13 674.60 18 15.17 1286 351 2.39 / 14.41 2 4
5 13 234.00 18 15.26 691 190 2.58 / 14.60 2 4
6 8 0.16 165 15.29 328 827 3.40 / 15.43 2 13
Average= 3.09
(KJ/cycle)

Cycle 3 GMT 28/ 3/2019 8:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 25 15.26 469 179 0.18 / 8.71 2 3
2 3 1024.04 1 15.26 1857 28 0.21 / 8.73 2 6
3 7 1523.40 38 15.05 2348 1343 1.55 / 10.08 2 5
4 13 1264.88 18 15.08 2051 557 2.11 / 10.63 2 4
5 13 685.88 18 15.16 1301 355 2.46 / 10.99 2 4
6 13 253.92 18 15.26 717 197 2.66 / 11.19 2 4
7 8 0.08 165 15.28 333 840 3.50 / 12.03 2 11
Average= 3.01
(KJ/cycle)

Cycle 2 GMT 27/ 3/2019 8:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 24 15.30 483 177 0.18 / 4.88 2 2
2 10 1020.00 2 15.21 1795 55 0.23 / 4.93 2 4
3 7 1506.56 74 14.98 2311 2562 2.79 / 7.49 2 4
4 13 277.12 18 15.26 745 205 3.00 / 7.70 2 4
5 8 0.16 165 15.30 328 828 3.83 / 8.53 2 8
Average= 2.84
(KJ/cycle)

Cycle 1 GMT 26/ 3/2019 9: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 23 15.45 428 152 0.15 / 1.88 3 3
2 10 1029.96 3 15.25 1776 81 0.23 / 1.96 2 3
3 3 1027.80 1 15.29 1834 28 0.26 / 1.99 2 4
4 7 999.08 74 15.13 1670 1870 2.13 / 3.86 2 7
5 8 0.04 165 15.34 334 845 2.98 / 4.70 2 10
Average= 2.35
(KJ/cycle)

Cycle 0 GMT 25/ 3/2019 22:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.28 22 15.59 504 173 0.17 / 0.17 3 3
2 7 179.56 74 15.55 500 575 0.75 / 0.75 3 3
3 8 0.16 240 15.52 262 976 1.72 / 1.72 3 10
Average= 1.72
(KJ/cycle)