SIO Argo Site:
Pump Diagnostics Page   



Serial= 10087 WMO= 4902918

Return

←PreviousNext→

Cycle 108 GMT 20/ 8/2020 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 29 14.18 464 191 0.19 / 557.60 5 34
2 7 2003.40 40 10.80 3186 1376 1.57 / 558.98 34 23
3 13 1938.88 20 12.44 3106 773 2.34 / 559.75 5 50
4 13 1847.44 20 12.59 2971 748 3.09 / 560.50 5 57
5 13 1305.80 20 13.03 2204 574 3.66 / 561.07 5 73
6 13 658.92 20 13.50 1287 347 4.01 / 561.42 5 89
7 13 29.08 20 14.19 369 105 4.11 / 561.52 5 78
8 8 -0.08 325 14.01 306 1393 5.51 / 562.92 5 137
Average= 5.16
(KJ/cycle)

Cycle 107 GMT 10/ 8/2020 16: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 29 14.17 483 198 0.20 / 552.08 5 34
2 7 2004.04 41 10.84 3187 1416 1.61 / 553.50 34 24
3 13 1934.72 20 12.41 3087 766 2.38 / 554.26 5 51
4 13 1838.20 20 12.60 2962 746 3.13 / 555.01 5 58
5 13 1194.00 20 13.13 2020 530 3.66 / 555.54 5 72
6 13 560.04 20 13.61 1098 299 3.96 / 555.84 5 80
7 13 55.48 20 14.14 412 117 4.07 / 555.96 5 75
8 8 -0.16 333 14.00 312 1455 5.53 / 557.41 5 137
Average= 5.16
(KJ/cycle)

Cycle 106 GMT 31/ 7/2020 16:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 29 14.21 459 189 0.19 / 546.67 5 31
2 7 2003.40 40 10.78 3192 1376 1.57 / 548.04 5 24
3 13 1931.72 20 12.40 3127 775 2.34 / 548.82 5 51
4 13 1835.36 20 12.59 2976 749 3.09 / 549.57 5 58
5 13 1180.72 20 13.13 2002 526 3.62 / 550.09 5 68
6 13 540.76 20 13.66 1048 286 3.90 / 550.38 5 73
7 13 27.36 20 14.18 381 108 4.01 / 550.49 5 89
8 8 0.00 317 14.01 314 1395 5.41 / 551.88 5 131
Average= 5.16
(KJ/cycle)

Cycle 105 GMT 21/ 7/2020 17:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 29 14.16 480 197 0.20 / 541.24 5 39
2 7 2003.24 41 10.79 3174 1404 1.60 / 542.65 39 25
3 13 1938.08 20 12.41 3107 771 2.37 / 543.42 5 51
4 13 1848.64 20 12.57 2993 752 3.12 / 544.17 5 56
5 13 1195.68 20 13.09 2061 540 3.66 / 544.71 5 74
6 13 566.96 20 13.60 1136 309 3.97 / 545.02 5 80
7 13 30.08 20 14.19 377 107 4.08 / 545.12 5 89
8 8 -0.08 315 14.03 306 1352 5.43 / 546.48 5 134
Average= 5.16
(KJ/cycle)

Cycle 104 GMT 11/ 7/2020 18:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 29 14.14 472 194 0.19 / 535.82 5 46
2 7 2003.72 40 10.86 3180 1381 1.57 / 537.20 46 26
3 13 1929.00 20 12.42 3079 765 2.34 / 537.97 5 50
4 13 1629.12 20 12.76 2689 686 3.03 / 538.65 5 64
5 13 1212.28 20 13.09 2079 544 3.57 / 539.20 5 76
6 13 653.76 20 13.54 1244 337 3.91 / 539.53 5 69
7 13 39.68 20 14.15 391 111 4.02 / 539.64 5 86
8 8 0.00 325 13.99 308 1400 5.42 / 541.04 5 132
Average= 5.15
(KJ/cycle)

Cycle 103 GMT 1/ 7/2020 19:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 29 14.12 485 199 0.20 / 530.31 5 49
2 7 2006.00 40 10.91 3180 1388 1.59 / 531.70 49 28
3 13 1934.28 20 12.41 3110 772 2.36 / 532.47 5 51
4 13 1836.96 20 12.59 2967 747 3.11 / 533.22 5 59
5 13 1066.80 20 13.21 1864 492 3.60 / 533.71 5 77
6 13 651.36 20 13.54 1226 332 3.93 / 534.04 5 77
7 13 8.16 20 14.17 347 98 4.03 / 534.14 5 79
8 8 -0.08 344 13.92 310 1484 5.51 / 535.63 5 138
Average= 5.15
(KJ/cycle)

Cycle 102 GMT 21/ 6/2020 20:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 29 14.14 482 198 0.20 / 524.83 5 42
2 7 2003.88 40 10.99 3180 1398 1.60 / 526.23 42 28
3 13 1924.92 20 12.43 3117 775 2.37 / 527.00 5 51
4 13 1729.12 20 12.71 2805 713 3.08 / 527.71 5 62
5 13 1078.76 20 13.20 1839 485 3.57 / 528.20 5 74
6 13 467.40 20 13.67 981 268 3.84 / 528.47 5 85
7 13 35.92 20 14.11 391 110 3.95 / 528.58 5 67
8 8 -0.20 351 13.89 315 1536 5.48 / 530.11 5 130
Average= 5.15
(KJ/cycle)

Cycle 101 GMT 11/ 6/2020 21:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 29 14.10 484 198 0.20 / 519.29 5 51
2 7 2008.04 40 10.98 3201 1406 1.60 / 520.70 51 29
3 13 1931.76 20 12.42 3098 770 2.37 / 521.47 5 52
4 13 1737.12 20 12.70 2855 725 3.10 / 522.19 5 63
5 13 1089.56 20 13.19 1870 493 3.59 / 522.69 5 72
6 13 562.08 20 13.60 1110 302 3.89 / 522.99 5 88
7 13 27.08 20 14.12 379 107 4.00 / 523.09 5 81
8 8 -0.16 350 13.88 316 1535 5.54 / 524.63 5 136
Average= 5.14
(KJ/cycle)

Cycle 100 GMT 1/ 6/2020 22:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 29 14.10 491 201 0.20 / 513.77 5 55
2 7 2002.64 40 11.02 3185 1404 1.60 / 515.17 55 29
3 13 1930.28 20 12.42 3105 771 2.38 / 515.94 5 51
4 13 1625.92 20 12.78 2657 679 3.06 / 516.62 5 66
5 13 1199.32 20 13.09 2073 543 3.60 / 517.16 5 78
6 13 560.28 20 13.59 1123 305 3.90 / 517.47 5 78
7 8 0.20 367 13.88 319 1625 5.53 / 519.09 5 131
Average= 5.14
(KJ/cycle)

Cycle 99 GMT 22/ 5/2020 23:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 29 14.15 477 196 0.20 / 508.12 5 51
2 7 2009.64 40 11.00 3195 1406 1.60 / 509.53 51 29
3 13 1937.32 20 12.40 3090 766 2.37 / 510.29 5 51
4 13 1841.52 20 12.57 2981 749 3.12 / 511.04 5 59
5 13 1175.00 20 13.12 2029 532 3.65 / 511.57 5 78
6 13 513.32 20 13.64 1048 286 3.94 / 511.86 5 65
7 13 41.56 20 14.09 408 115 4.05 / 511.97 5 85
8 8 -0.16 360 13.86 319 1592 5.64 / 513.57 5 132
Average= 5.14
(KJ/cycle)

Cycle 98 GMT 13/ 5/2020 0:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 29 14.09 506 207 0.21 / 502.69 5 58
2 7 2012.32 40 11.05 3202 1415 1.62 / 504.11 5 29
3 13 1938.12 20 12.41 3100 769 2.39 / 504.88 5 50
4 13 1534.56 20 12.86 2519 648 3.04 / 505.53 5 67
5 13 1224.00 20 13.10 2076 544 3.58 / 506.07 5 73
6 13 488.68 20 13.66 1007 275 3.86 / 506.34 5 85
7 13 69.84 20 14.08 433 122 3.98 / 506.47 5 91
8 8 0.04 338 13.95 309 1457 5.44 / 507.92 5 140
Average= 5.13
(KJ/cycle)

Cycle 97 GMT 3/ 5/2020 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 28 14.12 498 197 0.20 / 497.14 5 58
2 3 1025.68 1 11.84 1868 22 0.22 / 497.16 5 5
3 7 2009.84 40 11.07 3211 1422 1.64 / 498.58 5 30
4 13 1932.44 20 12.44 3124 777 2.42 / 499.36 5 51
5 13 1733.80 20 12.71 2840 722 3.14 / 500.08 5 62
6 13 1202.60 20 13.11 2066 542 3.68 / 500.62 5 78
7 13 447.72 20 13.70 959 263 3.94 / 500.89 5 74
8 8 0.00 356 13.87 324 1600 5.54 / 502.49 5 133
Average= 5.13
(KJ/cycle)

Cycle 96 GMT 23/ 4/2020 2:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 30 14.10 499 211 0.21 / 491.61 5 59
2 3 959.04 -1 14.10 499 0 0.00 / 491.61 5 59
3 7 2008.72 40 11.11 3187 1416 1.63 / 493.03 59 31
4 13 1934.36 20 12.41 3113 773 2.40 / 493.80 5 52
5 13 1839.24 20 12.59 2963 746 3.15 / 494.55 5 59
6 13 1090.52 20 13.18 1882 496 3.64 / 495.04 5 77
7 13 441.40 20 13.69 944 258 3.90 / 495.30 5 87
8 13 26.20 20 14.12 379 107 4.01 / 495.41 5 88
9 8 0.08 353 13.89 313 1535 5.54 / 496.94 5 135
Average= 5.12
(KJ/cycle)

Cycle 95 GMT 13/ 4/2020 3: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 30 14.08 497 210 0.21 / 485.88 5 62
2 7 2002.32 40 11.05 3189 1410 1.62 / 487.29 62 29
3 13 1929.52 20 12.41 3118 774 2.39 / 488.06 5 53
4 13 1830.88 20 12.59 2963 746 3.14 / 488.81 5 60
5 13 1257.76 20 13.05 2158 563 3.70 / 489.37 5 79
6 13 498.68 20 13.67 1001 274 3.98 / 489.64 5 66
7 13 173.36 20 13.94 586 163 4.14 / 489.81 5 92
8 8 0.24 363 13.88 316 1592 5.73 / 491.40 5 137
Average= 5.12
(KJ/cycle)

Cycle 94 GMT 3/ 4/2020 4: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 29 14.10 489 200 0.20 / 480.19 5 52
2 3 1038.80 1 12.45 1864 23 0.22 / 480.21 5 5
3 7 2005.44 41 11.19 3192 1464 1.69 / 481.68 5 32
4 13 1932.96 20 12.43 3104 772 2.46 / 482.45 5 50
5 13 1625.80 20 12.78 2688 687 3.15 / 483.14 5 66
6 13 1312.64 20 13.02 2236 582 3.73 / 483.72 5 74
7 13 748.16 20 13.47 1328 358 4.09 / 484.08 5 69
8 13 2.64 20 14.15 349 99 4.19 / 484.18 5 85
9 8 0.04 336 13.87 320 1491 5.68 / 485.67 5 131
Average= 5.11
(KJ/cycle)

Cycle 93 GMT 24/ 3/2020 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 29 14.10 493 202 0.20 / 474.58 5 58
2 7 2006.92 40 11.10 3195 1419 1.62 / 476.00 58 31
3 13 1942.44 20 12.40 3112 772 2.39 / 476.77 5 51
4 13 1846.76 20 12.59 2971 748 3.14 / 477.52 5 58
5 13 1057.68 20 13.19 1859 490 3.63 / 478.01 5 80
6 13 638.20 20 13.51 1248 337 3.97 / 478.34 5 87
7 8 -0.08 364 13.85 327 1649 5.62 / 479.99 5 133
Average= 5.11
(KJ/cycle)

Cycle 92 GMT 14/ 3/2020 5:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 29 14.16 488 200 0.20 / 468.91 5 53
2 7 2006.72 40 11.07 3192 1413 1.61 / 470.32 53 31
3 13 1944.72 20 12.36 3147 778 2.39 / 471.10 5 50
4 13 1852.12 20 12.54 2990 750 3.14 / 471.85 5 58
5 13 1192.64 20 13.09 2044 535 3.68 / 472.38 5 78
6 13 658.40 20 13.53 1235 334 4.01 / 472.72 5 63
7 13 115.08 20 14.03 485 136 4.15 / 472.85 5 67
8 13 1.48 20 14.15 350 99 4.25 / 472.95 5 86
9 8 0.04 320 13.88 320 1421 5.67 / 474.38 5 129
Average= 5.10
(KJ/cycle)

Cycle 91 GMT 4/ 3/2020 6:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 29 14.19 486 200 0.20 / 463.45 5 52
2 7 2007.76 40 11.01 3205 1411 1.61 / 464.86 52 30
3 13 1919.92 20 12.39 3083 764 2.38 / 465.62 5 51
4 13 1607.64 20 12.80 2665 682 3.06 / 466.30 5 65
5 13 817.80 20 13.40 1486 398 3.46 / 466.70 5 77
6 13 500.00 20 13.69 1000 274 3.73 / 466.98 5 80
7 13 272.52 20 13.90 721 200 3.93 / 467.18 5 78
8 13 190.40 20 13.98 609 170 4.10 / 467.35 5 88
9 8 0.00 317 13.98 307 1361 5.46 / 468.71 5 134
Average= 5.09
(KJ/cycle)

Cycle 90 GMT 23/ 2/2020 7:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 29 14.20 486 200 0.20 / 457.92 5 51
2 7 2005.08 40 11.11 3194 1419 1.62 / 459.34 51 31
3 13 1917.56 20 12.42 3070 763 2.38 / 460.10 5 51
4 13 1709.44 20 12.72 2799 712 3.09 / 460.81 5 62
5 13 1187.88 20 13.13 2014 529 3.62 / 461.34 5 74
6 13 641.76 20 13.58 1218 331 3.95 / 461.67 5 64
7 13 41.92 20 14.18 393 111 4.07 / 461.78 5 83
8 8 0.56 330 14.00 317 1465 5.53 / 463.25 5 132
Average= 5.09
(KJ/cycle)

Cycle 89 GMT 13/ 2/2020 8:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 29 14.16 488 200 0.20 / 452.28 5 52
2 7 2006.60 40 11.14 3193 1423 1.62 / 453.70 52 30
3 13 1939.08 20 12.39 3110 771 2.39 / 454.47 5 50
4 13 1844.88 20 12.55 2979 748 3.14 / 455.22 5 57
5 13 1189.24 20 13.09 2058 539 3.68 / 455.76 5 76
6 13 756.88 20 13.48 1387 374 4.05 / 456.13 5 73
7 13 37.76 20 14.17 396 112 4.17 / 456.25 5 87
8 8 1.68 331 13.97 318 1470 5.64 / 457.72 5 134
Average= 5.09
(KJ/cycle)

Cycle 88 GMT 3/ 2/2020 9: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 29 14.20 482 198 0.20 / 446.82 5 49
2 7 2005.04 40 11.17 3177 1419 1.62 / 448.24 49 32
3 13 1925.08 20 12.44 3070 764 2.38 / 449.00 5 50
4 13 1626.76 20 12.77 2696 689 3.07 / 449.69 5 65
5 13 1092.20 20 13.18 1922 507 3.58 / 450.20 5 79
6 13 574.28 20 13.59 1148 312 3.89 / 450.51 5 70
7 13 8.52 20 14.20 354 101 3.99 / 450.61 5 90
8 8 0.08 328 13.92 322 1470 5.46 / 452.08 5 145
Average= 5.08
(KJ/cycle)

Cycle 87 GMT 24/ 1/2020 10: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 29 14.18 495 204 0.20 / 441.45 5 48
2 7 2005.32 40 11.13 3195 1422 1.63 / 442.87 48 31
3 13 1925.00 20 12.41 3079 764 2.39 / 443.64 5 51
4 13 1630.76 20 12.79 2660 680 3.07 / 444.32 5 65
5 13 1128.08 20 13.16 1952 514 3.58 / 444.83 5 80
6 13 485.96 20 13.72 986 271 3.85 / 445.10 5 62
7 13 76.48 20 14.14 442 125 3.98 / 445.23 5 69
8 8 0.04 324 14.00 307 1393 5.37 / 446.62 5 135
Average= 5.08
(KJ/cycle)

Cycle 86 GMT 14/ 1/2020 10:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 29 14.20 479 197 0.20 / 436.07 5 45
2 7 2006.56 40 11.22 3194 1433 1.63 / 437.51 45 32
3 13 1922.64 20 12.45 3085 768 2.40 / 438.28 5 50
4 13 1605.64 20 12.82 2634 675 3.07 / 438.95 5 64
5 13 1177.16 20 13.13 2012 528 3.60 / 439.48 5 78
6 13 528.32 20 13.64 1092 298 3.90 / 439.78 5 81
7 13 30.76 20 14.20 383 109 4.01 / 439.89 5 88
8 8 0.08 311 13.99 313 1362 5.37 / 441.25 5 130
Average= 5.07
(KJ/cycle)

Cycle 85 GMT 4/ 1/2020 11:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 29 14.15 482 198 0.20 / 430.62 5 58
2 7 2002.56 40 11.37 3193 1452 1.65 / 432.07 58 34
3 13 1922.16 20 12.44 3096 770 2.42 / 432.84 5 53
4 13 1616.88 20 12.84 2649 680 3.10 / 433.52 5 66
5 13 1078.80 20 13.20 1890 499 3.60 / 434.02 5 82
6 13 639.44 20 13.54 1211 328 3.93 / 434.35 5 70
7 8 0.32 343 13.92 320 1528 5.46 / 435.88 5 142
Average= 5.07
(KJ/cycle)

Cycle 84 GMT 25/12/2019 12:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 29 14.20 480 198 0.20 / 425.25 5 54
2 7 2006.92 40 11.32 3187 1443 1.64 / 426.69 54 34
3 13 1934.84 20 12.44 3095 770 2.41 / 427.46 5 52
4 13 1838.20 20 12.63 2959 747 3.16 / 428.21 5 59
5 13 959.60 20 13.30 1664 443 3.60 / 428.65 5 71
6 13 328.52 20 13.80 785 217 3.82 / 428.87 5 83
7 8 2.76 356 13.87 314 1550 5.37 / 430.42 5 131
Average= 5.06
(KJ/cycle)

Cycle 83 GMT 15/12/2019 13:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 29 14.15 496 204 0.20 / 419.84 5 60
2 7 2007.60 40 11.35 3198 1452 1.66 / 421.30 60 35
3 13 1928.36 20 12.49 3086 771 2.43 / 422.07 5 51
4 13 1727.72 20 12.75 2786 710 3.14 / 422.78 5 63
5 13 993.28 20 13.27 1750 464 3.60 / 423.24 5 84
6 13 446.80 20 13.73 919 252 3.85 / 423.49 5 66
7 13 59.88 20 14.11 417 118 3.97 / 423.61 5 90
8 8 0.08 336 13.93 308 1442 5.41 / 425.05 5 139
Average= 5.06
(KJ/cycle)

Cycle 82 GMT 5/12/2019 14:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 29 14.21 479 197 0.20 / 414.27 5 37
2 7 2003.52 40 11.31 3195 1445 1.64 / 415.72 37 35
3 13 1923.44 20 12.44 3087 768 2.41 / 416.48 5 52
4 13 1826.00 20 12.61 2945 743 3.15 / 417.23 5 59
5 13 1050.72 20 13.24 1811 480 3.63 / 417.71 5 73
6 13 408.76 20 13.74 894 246 3.88 / 417.95 5 76
7 13 95.72 20 14.05 478 134 4.01 / 418.09 5 87
8 8 0.32 357 13.87 314 1555 5.57 / 419.64 5 130
Average= 5.06
(KJ/cycle)

Cycle 81 GMT 25/11/2019 15:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 29 14.18 481 198 0.20 / 408.77 5 60
2 7 2007.24 40 11.29 3202 1446 1.64 / 410.21 60 34
3 13 1924.44 20 12.47 3096 772 2.42 / 410.99 5 52
4 13 1726.48 20 12.73 2832 721 3.14 / 411.71 5 63
5 13 1082.80 20 13.20 1899 501 3.64 / 412.21 5 80
6 13 535.56 20 13.65 1045 285 3.92 / 412.49 5 69
7 13 57.96 20 14.12 429 121 4.04 / 412.61 5 85
8 13 32.68 20 14.10 394 111 4.16 / 412.73 5 99
9 13 19.04 20 14.05 368 103 4.26 / 412.83 5 98
10 13 5.84 20 14.05 348 98 4.36 / 412.93 5 92
11 8 -0.32 261 13.90 316 1146 5.50 / 414.07 5 136
Average= 5.05
(KJ/cycle)

Cycle 80 GMT 15/11/2019 16:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 29 14.17 498 205 0.20 / 403.43 5 58
2 7 2001.76 40 11.37 3180 1446 1.65 / 404.88 5 35
3 13 1911.40 20 12.48 3054 762 2.41 / 405.64 5 53
4 13 1609.00 20 12.83 2638 677 3.09 / 406.32 5 67
5 13 964.56 20 13.31 1701 453 3.54 / 406.77 5 79
6 13 344.80 20 13.81 807 223 3.77 / 406.99 5 74
7 13 72.48 20 14.09 446 126 3.89 / 407.12 5 90
8 8 0.00 337 13.90 310 1452 5.34 / 408.57 5 137
Average= 5.04
(KJ/cycle)

Cycle 79 GMT 5/11/2019 17: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 29 14.20 483 199 0.20 / 397.80 5 53
2 7 2005.68 40 11.28 3193 1441 1.64 / 399.25 53 35
3 13 1928.36 20 12.46 3097 772 2.41 / 400.02 5 52
4 13 1831.08 20 12.62 2954 746 3.16 / 400.76 5 60
5 13 1090.48 20 13.22 1890 500 3.66 / 401.26 5 73
6 13 369.16 20 13.76 854 235 3.89 / 401.50 5 80
7 13 39.52 20 14.10 408 115 4.01 / 401.61 5 93
8 8 0.28 358 13.82 326 1613 5.62 / 403.23 5 129
Average= 5.04
(KJ/cycle)

Cycle 78 GMT 26/10/2019 17:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 29 14.22 476 196 0.20 / 392.18 5 54
2 7 2004.96 40 11.27 3176 1432 1.63 / 393.61 54 34
3 13 1940.44 20 12.45 3096 771 2.40 / 394.38 5 52
4 13 1842.12 20 12.61 2985 753 3.15 / 395.13 5 59
5 13 1255.92 20 13.10 2113 554 3.71 / 395.69 5 69
6 13 523.60 20 13.66 1050 287 3.99 / 395.97 5 75
7 13 108.48 20 14.05 496 139 4.13 / 396.11 5 90
8 8 -0.12 346 13.91 310 1492 5.62 / 397.61 5 137
Average= 5.03
(KJ/cycle)

Cycle 77 GMT 16/10/2019 18:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 28 14.23 478 190 0.19 / 386.73 5 56
2 3 1020.28 1 11.67 1852 22 0.21 / 386.75 5 5
3 7 2004.20 41 11.29 3200 1481 1.69 / 388.23 5 34
4 13 1926.40 20 12.48 3082 769 2.46 / 389.00 5 52
5 13 1617.40 20 12.85 2645 680 3.14 / 389.68 5 67
6 13 1092.72 20 13.22 1866 493 3.64 / 390.17 5 70
7 13 544.24 20 13.67 1060 290 3.93 / 390.46 5 81
8 13 22.48 20 14.18 374 106 4.03 / 390.57 5 60
9 8 0.24 322 13.93 315 1413 5.44 / 391.98 5 131
Average= 5.03
(KJ/cycle)

Cycle 76 GMT 6/10/2019 19:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 28 14.19 489 194 0.19 / 381.38 5 52
2 7 2012.40 40 11.28 3201 1444 1.64 / 382.82 5 34
3 13 1937.20 20 12.47 3101 773 2.41 / 383.59 5 52
4 13 1528.40 20 12.92 2514 650 3.06 / 384.24 5 66
5 13 996.92 20 13.33 1689 450 3.51 / 384.69 5 74
6 13 483.12 20 13.73 974 267 3.78 / 384.96 5 69
7 13 67.60 20 14.11 432 122 3.90 / 385.08 5 87
8 8 0.12 334 13.91 313 1454 5.36 / 386.54 5 132
Average= 5.02
(KJ/cycle)

Cycle 75 GMT 26/ 9/2019 20:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 28 14.23 478 190 0.19 / 375.71 5 48
2 7 2002.76 40 11.24 3179 1429 1.62 / 377.14 48 35
3 13 1926.16 20 12.47 3061 763 2.38 / 377.91 5 53
4 13 1522.80 20 12.92 2521 651 3.03 / 378.56 5 68
5 13 1206.96 20 13.15 2037 536 3.57 / 379.09 5 72
6 13 436.08 20 13.75 913 251 3.82 / 379.34 5 69
7 13 105.80 20 14.02 486 136 3.96 / 379.48 5 76
8 8 -0.12 383 13.80 322 1702 5.66 / 381.18 5 136
Average= 5.02
(KJ/cycle)

Cycle 74 GMT 16/ 9/2019 21:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 28 14.29 472 189 0.19 / 369.92 5 34
2 7 2012.76 40 11.21 3207 1438 1.63 / 371.36 5 34
3 13 1935.72 20 12.51 3078 770 2.40 / 372.13 5 52
4 13 1622.32 20 12.84 2682 689 3.09 / 372.82 5 68
5 13 1417.64 20 13.02 2336 608 3.69 / 373.43 5 73
6 13 503.04 20 13.68 1013 277 3.97 / 373.70 5 67
7 13 40.00 20 14.09 413 116 4.09 / 373.82 5 71
8 13 26.28 20 14.01 399 112 4.20 / 373.93 5 89
9 8 -0.52 358 13.77 323 1592 5.79 / 375.52 5 135
Average= 5.01
(KJ/cycle)

Cycle 73 GMT 6/ 9/2019 22:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 28 14.25 497 198 0.20 / 364.38 5 40
2 7 2004.52 40 11.13 3194 1422 1.62 / 365.80 40 35
3 13 1928.40 20 12.50 3076 769 2.39 / 366.57 5 54
4 13 1726.96 20 12.80 2819 722 3.11 / 367.29 5 64
5 13 1200.48 20 13.20 1973 521 3.63 / 367.81 5 74
6 13 550.52 20 13.66 1069 292 3.92 / 368.11 5 68
7 13 103.44 20 14.05 485 136 4.06 / 368.24 5 79
8 13 21.16 20 14.11 376 106 4.17 / 368.35 5 95
9 8 -0.52 317 13.85 315 1383 5.55 / 369.73 5 133
Average= 5.00
(KJ/cycle)

Cycle 72 GMT 27/ 8/2019 23:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 28 14.26 471 188 0.19 / 358.56 5 38
2 7 2004.12 40 11.05 3225 1425 1.61 / 359.98 38 35
3 13 1923.92 20 12.51 3092 774 2.39 / 360.76 5 54
4 13 1628.80 20 12.86 2694 693 3.08 / 361.45 5 66
5 13 1196.88 20 13.20 1993 526 3.61 / 361.98 5 73
6 13 446.44 20 13.76 930 256 3.86 / 362.23 5 66
7 13 68.60 20 14.08 442 124 3.99 / 362.36 5 67
8 13 35.12 20 14.03 411 115 4.10 / 362.47 5 70
9 13 18.00 20 13.98 388 108 4.21 / 362.58 5 70
10 8 -0.64 358 13.76 325 1601 5.81 / 364.18 5 137
Average= 4.99
(KJ/cycle)

Cycle 71 GMT 18/ 8/2019 0:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 28 14.33 485 195 0.19 / 352.82 5 27
2 7 2005.60 40 11.05 3189 1410 1.60 / 354.23 5 33
3 13 1937.12 20 12.51 3087 772 2.38 / 355.01 5 52
4 13 1843.24 20 12.68 2973 754 3.13 / 355.76 5 58
5 13 1295.20 20 13.14 2158 567 3.70 / 356.33 5 73
6 13 525.16 20 13.71 1025 281 3.98 / 356.61 5 66
7 13 96.88 20 14.09 466 131 4.11 / 356.74 5 52
8 13 8.56 20 14.14 364 103 4.21 / 356.84 5 70
9 8 -0.32 346 13.80 320 1528 5.74 / 358.37 5 130
Average= 4.98
(KJ/cycle)

Cycle 70 GMT 8/ 8/2019 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 28 14.40 468 189 0.19 / 347.43 5 23
2 7 2010.16 40 11.02 3199 1410 1.60 / 348.84 5 31
3 13 1936.64 20 12.52 3074 770 2.37 / 349.61 5 51
4 13 1839.24 20 12.69 2959 751 3.12 / 350.36 5 57
5 13 1093.04 20 13.25 1877 497 3.62 / 350.86 5 74
6 13 565.40 20 13.69 1120 307 3.92 / 351.16 5 77
7 13 32.92 20 14.22 385 109 4.03 / 351.27 5 91
8 8 -0.12 310 13.97 313 1356 5.39 / 352.63 5 132
Average= 4.97
(KJ/cycle)

Cycle 69 GMT 29/ 7/2019 1:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 28 14.40 460 185 0.19 / 342.24 5 19
2 7 2006.40 41 10.90 3190 1426 1.61 / 343.66 5 30
3 13 1927.88 20 12.50 3096 774 2.39 / 344.44 5 50
4 13 1633.40 20 12.88 2682 691 3.08 / 345.13 5 64
5 13 1011.24 20 13.34 1767 471 3.55 / 345.60 5 75
6 13 490.24 20 13.78 1033 285 3.83 / 345.89 5 75
7 13 32.00 20 14.27 381 109 3.94 / 345.99 5 86
8 8 -0.04 282 14.04 315 1247 5.19 / 347.24 5 131
Average= 4.96
(KJ/cycle)

Cycle 68 GMT 19/ 7/2019 2:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 28 14.36 480 193 0.19 / 336.93 5 27
2 7 2009.24 41 11.14 3195 1459 1.65 / 338.39 5 30
3 13 1935.12 20 12.55 3098 778 2.43 / 339.16 5 50
4 13 1839.52 20 12.71 2946 749 3.18 / 339.91 5 57
5 13 1182.12 20 13.22 2003 530 3.71 / 340.44 5 71
6 13 532.76 20 13.74 1084 298 4.01 / 340.74 5 81
7 13 21.96 20 14.30 355 102 4.11 / 340.84 5 85
8 8 0.00 284 14.08 303 1212 5.32 / 342.05 5 141
Average= 4.96
(KJ/cycle)

Cycle 67 GMT 9/ 7/2019 3:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 27 14.43 450 175 0.18 / 331.62 5 19
2 3 1024.00 1 12.17 1855 23 0.20 / 331.65 5 5
3 7 2004.52 40 11.10 3188 1415 1.61 / 333.06 5 33
4 13 1926.16 20 12.54 3076 771 2.38 / 333.83 5 52
5 13 1522.36 20 12.98 2522 655 3.04 / 334.49 5 67
6 13 1099.92 20 13.29 1872 498 3.54 / 334.99 5 74
7 13 447.48 20 13.82 927 256 3.79 / 335.24 5 50
8 13 58.00 20 14.20 425 121 3.91 / 335.36 5 75
9 8 -0.36 310 13.99 316 1370 5.28 / 336.73 5 129
Average= 4.95
(KJ/cycle)

Cycle 66 GMT 29/ 6/2019 4:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 29 14.37 463 193 0.19 / 326.30 5 31
2 3 965.28 -1 14.37 463 0 0.00 / 326.30 5 31
3 7 2004.96 41 11.03 3191 1443 1.64 / 327.75 31 32
4 13 1923.00 20 12.54 3063 768 2.40 / 328.51 5 52
5 13 1722.56 20 12.84 2787 716 3.12 / 329.23 5 63
6 13 1300.00 20 13.17 2156 568 3.69 / 329.80 5 73
7 13 622.32 20 13.67 1169 320 4.01 / 330.12 5 72
8 13 40.32 20 14.27 385 110 4.12 / 330.23 5 88
9 8 0.48 287 14.05 303 1222 5.34 / 331.45 5 132
Average= 4.95
(KJ/cycle)

Cycle 65 GMT 19/ 6/2019 5:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 29 14.48 453 190 0.19 / 321.09 5 18
2 7 2004.24 40 10.89 3181 1386 1.58 / 322.48 18 30
3 13 1927.08 20 12.56 3092 777 2.35 / 323.26 5 51
4 13 1726.60 20 12.86 2789 717 3.07 / 323.97 5 60
5 13 1083.64 20 13.33 1869 498 3.57 / 324.47 5 76
6 13 530.20 20 13.76 1097 302 3.87 / 324.77 5 90
7 13 6.24 20 14.31 325 93 3.96 / 324.87 5 85
8 8 -0.20 294 14.05 301 1243 5.21 / 326.11 5 137
Average= 4.94
(KJ/cycle)

Cycle 64 GMT 9/ 6/2019 6:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 29 14.44 459 192 0.19 / 315.76 5 26
2 7 2005.60 40 10.88 3193 1390 1.58 / 317.15 26 27
3 13 1925.76 20 12.57 3070 772 2.35 / 317.92 5 48
4 13 1828.36 20 12.76 2948 752 3.11 / 318.68 5 55
5 13 1166.28 20 13.29 1998 531 3.64 / 319.21 5 71
6 13 731.64 20 13.65 1389 379 4.02 / 319.59 5 66
7 13 16.68 20 14.39 342 98 4.11 / 319.68 5 65
8 8 0.00 284 14.17 303 1219 5.33 / 320.90 5 143
Average= 4.94
(KJ/cycle)

Cycle 63 GMT 30/ 5/2019 7:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 29 14.43 460 192 0.19 / 310.54 5 27
2 7 2006.72 40 11.10 3196 1419 1.61 / 311.96 27 28
3 13 1926.72 20 12.57 3103 780 2.39 / 312.74 5 49
4 13 1729.96 20 12.87 2827 728 3.12 / 313.47 5 59
5 13 1179.76 20 13.29 2036 541 3.66 / 314.01 5 73
6 13 530.40 20 13.84 1119 310 3.97 / 314.32 5 79
7 13 5.36 20 14.39 318 92 4.06 / 314.41 5 69
8 8 0.08 277 14.15 295 1156 5.22 / 315.57 5 134
Average= 4.93
(KJ/cycle)

Cycle 62 GMT 20/ 5/2019 8: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 29 14.45 457 192 0.19 / 305.21 5 23
2 7 2004.80 40 11.26 3199 1441 1.63 / 306.65 5 27
3 13 1936.84 20 12.60 3108 783 2.42 / 307.44 5 48
4 13 1842.92 20 12.77 2964 757 3.17 / 308.19 5 54
5 13 1267.00 20 13.24 2159 572 3.74 / 308.76 5 72
6 13 587.88 20 13.80 1196 330 4.07 / 309.09 5 78
7 8 0.36 308 14.17 288 1257 5.33 / 310.35 5 131
Average= 4.93
(KJ/cycle)

Cycle 61 GMT 10/ 5/2019 9:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 28 14.47 456 185 0.18 / 300.09 5 24
2 7 2004.68 40 11.33 3203 1452 1.64 / 301.54 5 28
3 13 1925.04 20 12.63 3089 780 2.42 / 302.33 5 48
4 13 1521.32 20 13.05 2511 655 3.07 / 302.98 5 63
5 13 1105.88 20 13.40 1883 505 3.58 / 303.49 5 71
6 13 569.04 20 13.85 1159 321 3.90 / 303.81 5 77
7 8 -0.16 298 14.20 287 1214 5.11 / 305.02 5 129
Average= 4.92
(KJ/cycle)

Cycle 60 GMT 30/ 4/2019 10:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 28 14.43 470 190 0.19 / 295.02 5 26
2 7 2003.00 40 11.35 3190 1448 1.64 / 296.47 26 29
3 13 1930.84 20 12.63 3098 783 2.42 / 297.25 5 48
4 13 1624.04 20 13.01 2680 697 3.12 / 297.95 5 62
5 13 1001.24 20 13.51 1724 466 3.58 / 298.41 5 71
6 13 475.88 20 13.95 1017 284 3.87 / 298.70 5 75
7 13 10.24 20 14.42 318 92 3.96 / 298.79 5 66
8 8 -0.12 277 14.18 285 1119 5.08 / 299.91 5 133
Average= 4.92
(KJ/cycle)

Cycle 59 GMT 20/ 4/2019 11:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 28 14.44 461 186 0.19 / 289.67 5 25
2 7 2003.88 40 11.50 3192 1468 1.65 / 291.14 25 31
3 13 1917.00 20 12.70 3057 776 2.43 / 291.91 5 50
4 13 1718.36 20 12.94 2816 729 3.16 / 292.64 5 61
5 13 1149.24 20 13.36 2016 539 3.70 / 293.18 5 77
6 13 694.52 20 13.73 1295 356 4.05 / 293.54 5 50
7 8 0.36 298 14.15 307 1295 5.35 / 294.83 5 133
Average= 4.91
(KJ/cycle)

Cycle 58 GMT 10/ 4/2019 12:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 28 14.46 451 183 0.18 / 284.37 5 27
2 7 2006.32 40 11.57 3193 1478 1.66 / 285.85 27 33
3 13 1929.72 20 12.70 3087 784 2.44 / 286.63 5 51
4 13 1833.44 20 12.84 2962 761 3.21 / 287.39 5 57
5 13 1178.88 20 13.34 2049 547 3.75 / 287.94 5 77
6 13 413.68 20 13.98 949 265 4.02 / 288.21 5 79
7 8 -0.20 301 14.17 299 1275 5.29 / 289.48 5 141
Average= 4.91
(KJ/cycle)

Cycle 57 GMT 31/ 3/2019 13: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 28 14.46 462 187 0.19 / 279.28 5 29
2 3 1020.60 1 12.08 1867 23 0.21 / 279.30 5 5
3 7 2007.96 40 11.66 3212 1498 1.71 / 280.80 5 33
4 13 1935.76 20 12.72 3102 789 2.50 / 281.59 5 50
5 13 1306.00 20 13.28 2198 584 3.08 / 282.17 5 61
6 13 1103.44 20 13.46 1880 506 3.59 / 282.68 5 71
7 13 356.36 20 14.09 850 240 3.83 / 282.92 5 70
8 13 7.20 20 14.44 320 92 3.92 / 283.01 5 67
9 8 0.04 284 14.18 292 1176 5.09 / 284.19 5 132
Average= 4.90
(KJ/cycle)

Cycle 56 GMT 21/ 3/2019 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 29 14.49 454 191 0.19 / 273.92 5 27
2 3 967.40 -1 14.49 454 0 0.00 / 273.92 5 27
3 7 2006.84 40 11.72 3183 1492 1.68 / 275.41 27 34
4 13 1931.36 20 12.77 3096 791 2.47 / 276.20 5 50
5 13 1835.88 20 12.91 2957 763 3.24 / 276.96 5 57
6 13 1144.44 20 13.43 1953 525 3.76 / 277.49 5 73
7 13 586.88 20 13.84 1209 335 4.10 / 277.82 5 82
8 8 0.08 301 14.17 298 1271 5.37 / 279.09 5 151
Average= 4.90
(KJ/cycle)

Cycle 55 GMT 11/ 3/2019 14:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 27 14.42 483 188 0.19 / 268.66 5 32
2 10 1034.24 4 13.87 1885 105 0.29 / 268.76 5 45
3 3 925.76 -1 13.87 1885 0 0.10 / 268.76 5 45
4 7 2009.12 40 11.86 3214 1525 1.82 / 270.28 45 34
5 13 1932.08 20 12.80 3101 794 2.61 / 271.08 5 50
6 13 1318.08 20 13.30 2255 600 3.21 / 271.68 5 71
7 13 1119.88 20 13.48 1885 508 3.72 / 272.19 5 58
8 13 571.36 20 13.90 1178 327 4.05 / 272.51 5 77
9 8 0.36 291 14.22 293 1212 5.26 / 273.73 5 132
Average= 4.89
(KJ/cycle)

Cycle 54 GMT 1/ 3/2019 16:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 27 14.43 457 178 0.18 / 263.51 5 34
2 7 2003.16 40 11.90 3188 1517 1.70 / 265.03 34 39
3 13 1918.40 20 12.78 3070 785 2.48 / 265.81 5 53
4 13 1318.24 20 13.29 2237 595 3.07 / 266.41 5 74
5 13 1117.80 20 13.44 1927 518 3.59 / 266.92 5 76
6 13 345.24 20 14.04 845 237 3.83 / 267.16 5 86
7 13 48.88 20 14.36 385 111 3.94 / 267.27 5 80
8 8 0.44 282 14.14 300 1196 5.14 / 268.47 5 133
Average= 4.88
(KJ/cycle)

Cycle 53 GMT 19/ 2/2019 16:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 27 14.43 452 176 0.18 / 258.14 5 37
2 7 2003.24 40 11.99 3186 1528 1.70 / 259.67 37 40
3 13 1910.20 20 12.81 3064 785 2.49 / 260.45 5 55
4 13 1715.04 20 13.05 2811 734 3.22 / 261.19 5 64
5 13 907.28 20 13.58 1627 442 3.66 / 261.63 5 81
6 13 471.52 20 13.89 1028 286 3.95 / 261.91 5 90
7 13 85.96 20 14.28 449 128 4.08 / 262.04 5 88
8 13 48.32 20 14.28 386 110 4.19 / 262.15 5 87
9 8 -0.32 280 14.11 298 1177 5.37 / 263.33 5 141
Average= 4.88
(KJ/cycle)

Cycle 52 GMT 9/ 2/2019 17:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 27 14.43 470 183 0.18 / 253.06 5 37
2 7 2008.48 40 12.07 3217 1553 1.74 / 254.61 5 42
3 13 1916.76 20 12.83 3049 782 2.52 / 255.39 5 56
4 13 1500.60 20 13.22 2454 649 3.17 / 256.04 5 71
5 13 762.36 20 13.67 1443 395 3.56 / 256.44 5 88
6 13 237.32 20 14.10 677 191 3.75 / 256.63 5 92
7 13 7.56 20 14.35 328 94 3.85 / 256.72 5 91
8 8 0.08 301 14.08 293 1242 5.09 / 257.96 5 139
Average= 4.87
(KJ/cycle)

Cycle 51 GMT 30/ 1/2019 18:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 27 14.41 477 186 0.19 / 247.94 5 40
2 7 2017.68 40 12.12 3215 1559 1.74 / 249.50 5 41
3 13 1948.84 20 12.83 3094 794 2.54 / 250.29 5 54
4 13 1544.28 20 13.18 2558 674 3.21 / 250.96 5 69
5 13 995.12 20 13.53 1784 483 3.70 / 251.45 5 84
6 13 238.48 20 14.12 683 193 3.89 / 251.64 5 92
7 8 0.04 294 14.15 297 1236 5.12 / 252.88 5 133
Average= 4.86
(KJ/cycle)

Cycle 50 GMT 20/ 1/2019 19: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 27 14.50 443 173 0.17 / 242.57 5 23
2 7 2005.88 40 12.23 3187 1559 1.73 / 244.13 23 44
3 13 1918.20 20 12.87 3054 786 2.52 / 244.91 5 56
4 13 1716.88 20 13.10 2775 727 3.25 / 245.64 5 66
5 13 933.08 20 13.61 1607 437 3.68 / 246.08 5 77
6 13 386.32 20 13.97 876 245 3.93 / 246.32 5 82
7 13 71.88 20 14.27 436 124 4.05 / 246.45 5 94
8 8 0.08 305 14.08 304 1305 5.36 / 247.75 5 130
Average= 4.86
(KJ/cycle)

Cycle 49 GMT 10/ 1/2019 19:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 27 14.50 458 179 0.18 / 237.62 5 21
2 7 2013.00 40 12.28 3193 1568 1.75 / 239.18 21 42
3 13 1936.84 20 12.88 3069 791 2.54 / 239.97 5 54
4 13 1408.00 20 13.32 2322 619 3.16 / 240.59 5 71
5 13 879.88 20 13.64 1597 436 3.59 / 241.03 5 82
6 13 236.44 20 14.19 672 191 3.78 / 241.22 5 84
7 8 0.20 287 14.21 288 1175 4.96 / 242.39 5 137
Average= 4.85
(KJ/cycle)

Cycle 48 GMT 31/12/2018 20:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 27 14.54 425 167 0.17 / 232.58 6 19
2 7 2004.40 40 12.29 3180 1563 1.73 / 234.14 19 42
3 13 1921.60 20 12.87 3065 789 2.52 / 234.93 5 54
4 13 1519.12 20 13.23 2493 660 3.18 / 235.59 5 67
5 13 869.52 20 13.67 1532 419 3.60 / 236.01 5 75
6 13 328.28 20 14.12 809 228 3.83 / 236.24 5 81
7 8 -0.04 296 14.24 285 1201 5.03 / 237.44 5 135
Average= 4.85
(KJ/cycle)

Cycle 47 GMT 21/12/2018 21:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 27 14.53 442 173 0.17 / 227.50 6 17
2 7 2011.80 41 12.21 3214 1609 1.78 / 229.10 5 40
3 13 1930.24 20 12.85 3090 794 2.58 / 229.90 5 52
4 13 1514.56 20 13.23 2488 658 3.23 / 230.56 5 65
5 13 983.12 20 13.60 1700 462 3.70 / 231.02 5 62
6 13 333.80 20 14.13 794 224 3.92 / 231.24 5 81
7 13 56.04 20 14.42 371 107 4.03 / 231.35 5 74
8 8 0.12 270 14.26 275 1059 5.09 / 232.41 5 140
Average= 4.84
(KJ/cycle)

Cycle 46 GMT 11/12/2018 22:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 27 14.56 444 175 0.17 / 222.32 6 14
2 7 2005.92 40 12.16 3192 1553 1.73 / 223.87 14 41
3 13 1923.64 20 12.82 3068 787 2.51 / 224.66 5 52
4 13 1609.76 20 13.17 2609 687 3.20 / 225.34 5 62
5 13 958.76 20 13.62 1634 445 3.65 / 225.79 5 72
6 13 620.76 20 13.85 1228 340 3.99 / 226.13 5 85
7 13 1.16 20 14.48 292 85 4.07 / 226.21 5 77
8 8 0.12 278 14.22 280 1107 5.18 / 227.32 5 147
Average= 4.84
(KJ/cycle)

Cycle 45 GMT 1/12/2018 23:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 27 14.59 431 170 0.17 / 217.34 6 12
2 7 2003.44 40 12.13 3186 1546 1.72 / 218.88 12 40
3 13 1916.80 20 12.80 3075 787 2.50 / 219.67 5 51
4 13 1402.24 20 13.28 2345 623 3.13 / 220.29 5 68
5 13 884.88 20 13.67 1559 426 3.55 / 220.72 5 58
6 13 349.76 20 14.14 840 238 3.79 / 220.96 5 76
7 8 0.04 291 14.30 285 1186 4.98 / 222.14 5 139
Average= 4.83
(KJ/cycle)

Cycle 44 GMT 22/11/2018 0:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 27 14.61 429 169 0.17 / 212.28 6 10
2 7 2004.00 41 12.10 3192 1584 1.75 / 213.87 10 39
3 13 1922.76 20 12.79 3066 784 2.54 / 214.65 5 51
4 13 1492.80 20 13.21 2449 647 3.18 / 215.30 5 64
5 13 956.04 20 13.62 1663 453 3.64 / 215.75 5 75
6 13 319.96 20 14.19 793 225 3.86 / 215.98 5 73
7 8 -0.04 296 14.32 281 1191 5.05 / 217.17 5 142
Average= 4.83
(KJ/cycle)

Cycle 43 GMT 12/11/2018 1:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 27 14.61 426 168 0.17 / 207.10 6 11
2 7 2007.60 40 12.10 3187 1543 1.71 / 208.64 11 40
3 13 1923.36 20 12.77 3081 787 2.50 / 209.43 5 51
4 13 1720.28 20 13.04 2812 733 3.23 / 210.16 5 62
5 13 961.52 20 13.62 1681 458 3.69 / 210.62 5 72
6 13 433.28 20 14.08 970 273 3.96 / 210.89 5 77
7 13 43.56 20 14.49 365 106 4.07 / 211.00 5 63
8 8 -0.04 275 14.31 284 1118 5.19 / 212.12 5 145
Average= 4.82
(KJ/cycle)

Cycle 42 GMT 2/11/2018 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 27 14.62 432 171 0.17 / 202.03 6 10
2 7 2003.56 40 12.16 3194 1554 1.72 / 203.59 10 41
3 13 1921.04 20 12.80 3075 787 2.51 / 204.38 5 52
4 13 1508.40 20 13.20 2506 662 3.17 / 205.04 5 67
5 13 962.48 20 13.59 1743 474 3.65 / 205.51 5 79
6 13 305.48 20 14.22 780 222 3.87 / 205.73 5 73
7 13 38.56 20 14.51 356 103 3.97 / 205.84 5 66
8 13 19.80 20 14.45 322 93 4.06 / 205.93 5 66
9 8 -0.32 249 14.26 282 1001 5.07 / 206.93 5 131
Average= 4.81
(KJ/cycle)

Cycle 41 GMT 23/10/2018 3:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 27 14.65 430 170 0.17 / 196.99 6 9
2 7 2008.52 40 12.17 3189 1552 1.72 / 198.54 9 40
3 13 1923.52 20 12.85 3067 788 2.51 / 199.33 5 51
4 13 1605.08 20 13.16 2647 697 3.21 / 200.03 5 64
5 13 940.28 20 13.62 1710 466 3.67 / 200.49 5 78
6 13 282.00 20 14.26 729 208 3.88 / 200.70 5 72
7 13 1.44 20 14.56 288 84 3.96 / 200.79 5 71
8 8 -0.04 270 14.30 279 1077 5.04 / 201.86 5 136
Average= 4.81
(KJ/cycle)

Cycle 40 GMT 13/10/2018 4:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 27 14.65 446 176 0.18 / 191.97 6 8
2 7 2002.44 40 12.26 3200 1569 1.75 / 193.54 8 41
3 13 1915.36 20 12.88 3080 793 2.54 / 194.34 5 51
4 13 1489.88 20 13.29 2473 657 3.20 / 194.99 5 65
5 13 850.96 20 13.71 1585 435 3.63 / 195.43 5 81
6 13 311.00 20 14.24 786 224 3.85 / 195.65 5 73
7 8 -0.08 287 14.35 284 1170 5.02 / 196.82 5 130
Average= 4.80
(KJ/cycle)

Cycle 39 GMT 3/10/2018 5:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 27 14.70 424 168 0.17 / 186.71 6 7
2 7 2009.04 40 12.37 3216 1591 1.76 / 188.30 5 41
3 13 1920.40 20 12.92 3087 798 2.56 / 189.10 5 52
4 13 1610.36 20 13.23 2651 701 3.26 / 189.80 5 65
5 13 946.72 20 13.67 1738 475 3.73 / 190.27 5 81
6 13 495.24 20 14.07 1069 301 4.03 / 190.57 5 82
7 13 28.92 20 14.54 353 103 4.14 / 190.68 5 65
8 8 -0.08 268 14.31 292 1120 5.26 / 191.80 5 129
Average= 4.79
(KJ/cycle)

Cycle 38 GMT 23/ 9/2018 6: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 27 14.71 427 170 0.17 / 181.67 6 7
2 7 2006.52 40 12.46 3195 1592 1.76 / 183.26 7 42
3 13 1919.96 20 12.97 3071 797 2.56 / 184.06 5 52
4 13 1395.32 20 13.39 2359 632 3.19 / 184.69 5 68
5 13 869.28 20 13.76 1622 446 3.64 / 185.14 5 80
6 13 230.92 20 14.36 670 192 3.83 / 185.33 5 68
7 13 28.24 20 14.56 340 99 3.93 / 185.43 5 63
8 8 -0.24 272 14.32 285 1110 5.04 / 186.54 6 143
Average= 4.78
(KJ/cycle)

Cycle 37 GMT 13/ 9/2018 6:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 27 14.69 414 164 0.16 / 176.58 6 7
2 7 2005.52 41 12.57 3171 1634 1.80 / 178.22 7 44
3 13 1918.68 20 13.02 3071 800 2.60 / 179.02 5 55
4 13 1397.96 20 13.41 2346 629 3.23 / 179.65 5 71
5 13 875.12 20 13.77 1624 447 3.67 / 180.10 5 84
6 13 314.96 20 14.29 793 227 3.90 / 180.32 5 75
7 13 36.88 20 14.57 349 102 4.00 / 180.42 5 67
8 8 -0.40 265 14.33 284 1078 5.08 / 181.50 5 137
Average= 4.78
(KJ/cycle)

Cycle 36 GMT 3/ 9/2018 7:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 27 14.71 426 169 0.17 / 171.56 6 7
2 7 2002.48 41 12.66 3176 1649 1.82 / 173.21 7 44
3 13 1907.32 20 13.08 3041 796 2.61 / 174.01 5 54
4 13 1485.12 20 13.40 2484 666 3.28 / 174.67 5 69
5 13 830.68 20 13.83 1564 433 3.71 / 175.11 5 84
6 13 93.72 20 14.51 452 131 3.84 / 175.24 5 67
7 13 11.40 20 14.59 316 92 3.93 / 175.33 5 63
8 8 -0.28 265 14.34 287 1091 5.03 / 176.42 6 134
Average= 4.77
(KJ/cycle)

Cycle 35 GMT 24/ 8/2018 7:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 27 14.71 448 178 0.18 / 166.39 6 8
2 7 2002.20 40 12.72 3182 1619 1.80 / 168.01 5 44
3 13 1912.00 20 13.12 3069 805 2.60 / 168.82 5 55
4 13 1488.72 20 13.44 2508 674 3.28 / 169.49 5 70
5 13 827.60 20 13.85 1566 434 3.71 / 169.93 5 84
6 13 387.24 20 14.25 914 260 3.97 / 170.19 5 78
7 13 13.68 20 14.61 325 95 4.07 / 170.28 5 67
8 8 -0.20 265 14.34 293 1113 5.18 / 171.39 5 135
Average= 4.76
(KJ/cycle)

Cycle 34 GMT 14/ 8/2018 8:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 27 14.74 414 165 0.16 / 161.33 6 8
2 7 2008.56 40 12.80 3159 1617 1.78 / 162.95 8 43
3 13 1915.80 20 13.15 3073 808 2.59 / 163.76 5 55
4 13 1486.16 20 13.48 2471 666 3.26 / 164.42 5 69
5 13 832.20 20 13.88 1565 434 3.69 / 164.86 5 83
6 13 173.32 20 14.47 573 166 3.86 / 165.02 5 68
7 13 13.60 20 14.63 319 93 3.95 / 165.12 5 65
8 8 -0.32 265 14.36 289 1100 5.05 / 166.22 5 137
Average= 4.75
(KJ/cycle)

Cycle 33 GMT 4/ 8/2018 9:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 27 14.75 429 171 0.17 / 156.37 6 8
2 7 2003.20 40 12.88 3161 1629 1.80 / 157.99 8 45
3 13 1914.32 20 13.19 3067 809 2.61 / 158.80 5 55
4 13 1382.00 20 13.57 2311 627 3.24 / 159.43 5 71
5 13 752.48 20 13.97 1448 405 3.64 / 159.84 5 83
6 13 213.40 20 14.48 625 181 3.82 / 160.02 5 67
7 13 2.24 20 14.66 295 86 3.91 / 160.10 5 65
8 8 -0.40 261 14.39 283 1063 4.97 / 161.17 5 131
Average= 4.74
(KJ/cycle)

Cycle 32 GMT 25/ 7/2018 10:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 27 14.73 429 171 0.17 / 150.26 6 8
2 7 2003.28 40 12.94 3128 1619 1.79 / 151.88 8 44
3 13 1916.80 20 13.25 3006 797 2.59 / 152.68 5 53
4 13 1611.52 20 13.49 2600 701 3.29 / 153.38 5 62
5 13 1518.40 20 13.51 2486 672 3.96 / 154.05 5 68
6 13 1197.20 20 13.73 2045 562 4.52 / 154.61 5 76
7 13 686.60 20 14.08 1330 375 4.90 / 154.99 5 81
8 13 36.16 20 14.65 341 100 5.00 / 155.09 5 63
9 8 -0.20 277 14.41 278 1110 6.11 / 156.20 5 132
Average= 4.73
(KJ/cycle)

Cycle 31 GMT 15/ 7/2018 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 27 14.73 432 172 0.17 / 145.14 6 9
2 7 2002.04 40 12.98 3121 1620 1.79 / 146.76 9 44
3 13 1908.16 20 13.27 3013 800 2.59 / 147.56 5 54
4 13 1586.40 20 13.53 2533 685 3.28 / 148.24 5 59
5 13 909.28 20 13.90 1623 451 3.73 / 148.70 5 73
6 13 353.32 20 14.37 843 242 3.97 / 148.94 5 76
7 13 24.04 20 14.66 326 96 4.07 / 149.03 5 66
8 8 -0.20 265 14.40 277 1057 5.12 / 150.09 5 139
Average= 4.69
(KJ/cycle)

Cycle 30 GMT 5/ 7/2018 12:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 27 14.72 449 178 0.18 / 140.11 6 11
2 7 2004.52 40 13.01 3137 1632 1.81 / 141.75 11 46
3 13 1915.52 20 13.28 3034 806 2.62 / 142.55 5 56
4 13 1477.40 20 13.60 2389 650 3.27 / 143.20 5 67
5 13 811.64 20 13.99 1514 424 3.69 / 143.63 5 81
6 13 175.80 20 14.53 585 170 3.86 / 143.80 5 68
7 13 17.96 20 14.67 324 95 3.96 / 143.89 5 65
8 8 -0.08 263 14.40 284 1076 5.03 / 144.97 5 135
Average= 4.68
(KJ/cycle)

Cycle 29 GMT 25/ 6/2018 13:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 26 14.73 423 162 0.16 / 135.02 6 11
2 7 2004.84 41 13.04 3115 1665 1.83 / 136.68 5 45
3 13 1911.32 20 13.30 3034 807 2.63 / 137.49 5 56
4 13 1403.28 20 13.65 2292 626 3.26 / 138.11 5 70
5 13 957.20 20 13.91 1696 472 3.73 / 138.59 5 78
6 13 283.96 20 14.45 740 214 3.95 / 138.80 5 72
7 8 -0.16 279 14.43 282 1135 5.08 / 139.94 5 134
Average= 4.66
(KJ/cycle)

Cycle 28 GMT 15/ 6/2018 14: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 26 14.73 424 162 0.16 / 130.08 6 14
2 3 1039.16 1 14.26 1857 26 0.19 / 130.11 5 5
3 7 2003.28 40 13.05 3179 1659 1.85 / 131.77 5 45
4 13 1925.80 20 13.32 3074 819 2.67 / 132.59 5 53
5 13 1381.24 20 13.69 2275 623 3.29 / 133.21 5 67
6 13 831.36 20 14.02 1533 430 3.72 / 133.64 5 80
7 13 81.24 20 14.64 426 125 3.84 / 133.76 5 63
8 8 0.04 277 14.43 273 1091 4.94 / 134.85 5 129
Average= 4.65
(KJ/cycle)

Cycle 27 GMT 5/ 6/2018 15: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 26 14.71 434 166 0.17 / 125.17 6 15
2 7 2005.64 40 13.07 3168 1656 1.82 / 126.83 15 45
3 13 1918.44 20 13.35 3038 811 2.63 / 127.64 5 54
4 13 1479.04 20 13.63 2417 659 3.29 / 128.30 5 59
5 13 810.52 20 14.08 1461 411 3.70 / 128.71 5 73
6 13 76.00 20 14.66 408 120 3.82 / 128.83 5 62
7 8 -0.12 279 14.44 271 1092 4.92 / 129.92 5 129
Average= 4.64
(KJ/cycle)

Cycle 26 GMT 26/ 5/2018 16: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 26 14.72 446 171 0.17 / 120.25 6 14
2 7 2004.20 40 13.08 3157 1652 1.82 / 121.90 5 47
3 13 1816.28 20 13.43 2903 780 2.60 / 122.68 5 59
4 13 1296.28 20 13.72 2171 596 3.20 / 123.27 5 71
5 13 847.32 20 14.03 1523 427 3.63 / 123.70 5 74
6 13 173.60 20 14.55 580 169 3.79 / 123.87 5 73
7 8 -0.16 275 14.41 286 1133 4.93 / 125.00 5 134
Average= 4.63
(KJ/cycle)

Cycle 25 GMT 16/ 5/2018 16:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 25 14.69 444 163 0.16 / 115.30 6 18
2 7 2007.52 40 13.08 3178 1663 1.83 / 116.96 5 48
3 13 1918.84 20 13.33 3024 806 2.63 / 117.77 5 55
4 13 1389.52 20 13.69 2266 620 3.25 / 118.39 5 68
5 13 841.60 20 14.02 1528 428 3.68 / 118.82 5 75
6 13 84.88 20 14.62 431 126 3.81 / 118.94 5 74
7 8 -0.04 277 14.39 284 1132 4.94 / 120.08 5 138
Average= 4.62
(KJ/cycle)

Cycle 24 GMT 6/ 5/2018 17:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 24 14.72 464 164 0.16 / 110.28 6 16
2 3 1046.68 1 14.40 1905 27 0.19 / 110.31 5 7
3 7 2003.04 40 13.07 3200 1673 1.86 / 111.98 7 48
4 13 1916.08 20 13.30 3081 820 2.68 / 112.80 5 57
5 13 1286.36 20 13.72 2200 604 3.29 / 113.40 5 72
6 13 849.48 20 13.99 1587 444 3.73 / 113.85 5 84
7 13 95.20 20 14.62 463 135 3.87 / 113.98 5 74
8 8 -0.08 275 14.38 292 1155 5.02 / 115.14 5 134
Average= 4.61
(KJ/cycle)

Cycle 23 GMT 26/ 4/2018 18:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 26 14.70 462 177 0.18 / 105.24 5 21
2 3 965.60 -1 14.70 462 0 0.00 / 105.24 5 21
3 7 2004.08 40 13.11 3158 1656 1.83 / 106.90 21 48
4 13 1912.60 20 13.33 3053 814 2.65 / 107.71 5 57
5 13 1497.40 20 13.62 2477 675 3.32 / 108.39 5 70
6 13 814.12 20 14.02 1529 429 3.75 / 108.81 5 85
7 13 38.88 20 14.67 380 111 3.86 / 108.93 5 72
8 8 0.08 277 14.37 299 1190 5.05 / 110.12 5 135
Average= 4.59
(KJ/cycle)

Cycle 22 GMT 16/ 4/2018 19:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 26 14.68 464 177 0.18 / 100.15 5 24
2 7 2005.16 40 13.11 3160 1657 1.83 / 101.81 24 47
3 13 1909.68 20 13.33 3062 816 2.65 / 102.63 5 56
4 13 1383.32 20 13.67 2351 643 3.29 / 103.27 5 71
5 13 736.28 20 14.08 1442 406 3.70 / 103.68 5 84
6 13 279.88 20 14.45 752 217 3.92 / 103.89 5 81
7 8 -0.28 275 14.38 296 1171 5.09 / 105.06 5 135
Average= 4.57
(KJ/cycle)

Cycle 21 GMT 6/ 4/2018 20:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 26 14.68 447 171 0.17 / 95.29 5 22
2 7 2003.00 40 13.12 3159 1658 1.83 / 96.94 22 48
3 13 1809.48 20 13.43 2932 788 2.62 / 97.73 5 61
4 13 1076.16 20 13.85 1930 535 3.15 / 98.27 5 79
5 13 767.36 20 14.07 1483 417 3.57 / 98.68 5 84
6 13 63.64 20 14.65 425 125 3.69 / 98.81 5 73
7 8 -0.04 270 14.38 301 1169 4.86 / 99.98 5 135
Average= 4.54
(KJ/cycle)

Cycle 20 GMT 27/ 3/2018 20:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 26 14.69 469 179 0.18 / 90.29 5 26
2 7 2003.68 40 13.09 3196 1673 1.85 / 91.96 5 48
3 13 1906.28 20 13.32 3066 817 2.67 / 92.78 5 58
4 13 1273.40 20 13.73 2199 604 3.27 / 93.38 5 76
5 13 741.60 20 14.08 1443 406 3.68 / 93.79 5 85
6 13 90.84 20 14.63 466 136 3.82 / 93.93 5 75
7 8 0.28 272 14.37 304 1188 5.00 / 95.12 5 133
Average= 4.53
(KJ/cycle)

Cycle 19 GMT 17/ 3/2018 21:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 25 14.69 461 169 0.17 / 85.19 5 24
2 7 2010.52 41 13.10 3198 1718 1.89 / 86.91 5 46
3 13 1919.24 20 13.30 3114 828 2.72 / 87.73 5 55
4 13 1375.88 20 13.69 2350 643 3.36 / 88.38 5 71
5 13 711.64 20 14.11 1413 399 3.76 / 88.78 5 82
6 13 79.60 20 14.65 443 130 3.89 / 88.91 5 72
7 8 0.12 272 14.38 308 1205 5.09 / 90.11 5 139
Average= 4.51
(KJ/cycle)

Cycle 18 GMT 7/ 3/2018 22: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 25 14.70 460 169 0.17 / 80.05 5 24
2 7 2004.88 40 13.09 3186 1668 1.84 / 81.72 24 48
3 13 1912.04 20 13.33 3078 821 2.66 / 82.54 5 56
4 13 1589.40 20 13.56 2647 718 3.38 / 83.26 5 67
5 13 685.00 20 14.12 1367 386 3.76 / 83.64 5 84
6 13 245.96 20 14.50 704 204 3.97 / 83.85 5 78
7 8 0.16 275 14.40 296 1172 5.14 / 85.02 5 133
Average= 4.47
(KJ/cycle)

Cycle 17 GMT 25/ 2/2018 22:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 25 14.72 454 167 0.17 / 74.99 5 23
2 7 2008.92 41 13.09 3203 1719 1.89 / 76.71 5 47
3 13 1916.60 20 13.31 3094 824 2.71 / 77.53 5 57
4 13 1263.96 20 13.74 2203 605 3.32 / 78.14 5 75
5 13 729.48 20 14.09 1438 405 3.72 / 78.54 5 84
6 13 175.04 20 14.57 598 174 3.89 / 78.72 5 76
7 8 -0.36 273 14.40 296 1164 5.06 / 79.88 5 131
Average= 4.44
(KJ/cycle)

Cycle 16 GMT 15/ 2/2018 23:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 24 14.71 461 163 0.16 / 69.81 5 23
2 3 1031.44 1 14.46 1898 27 0.19 / 69.84 5 5
3 7 2003.92 40 13.08 3179 1663 1.85 / 71.50 5 48
4 13 1913.88 20 13.30 3085 821 2.67 / 72.32 5 57
5 13 1382.20 20 13.67 2362 646 3.32 / 72.97 5 74
6 13 810.52 20 14.03 1547 434 3.75 / 73.40 5 84
7 13 357.24 20 14.39 880 253 4.01 / 73.66 5 83
8 8 -0.08 270 14.40 300 1166 5.17 / 74.82 5 130
Average= 4.40
(KJ/cycle)

Cycle 15 GMT 5/ 2/2018 23:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 26 14.73 422 162 0.16 / 64.70 5 23
2 3 956.72 -1 14.73 422 0 0.00 / 64.70 5 23
3 7 2004.20 40 13.08 3163 1655 1.82 / 66.36 23 47
4 13 1907.24 20 13.31 3060 815 2.63 / 67.17 5 55
5 13 1473.48 20 13.62 2473 674 3.30 / 67.85 5 68
6 13 889.48 20 13.98 1663 465 3.77 / 68.31 5 82
7 13 99.60 20 14.63 486 142 3.91 / 68.45 5 76
8 8 0.16 271 14.39 307 1197 5.11 / 69.65 5 137
Average= 4.35
(KJ/cycle)

Cycle 14 GMT 27/ 1/2018 0:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 26 14.83 411 158 0.16 / 59.84 6 19
2 7 2004.84 40 13.08 3134 1640 1.80 / 61.48 19 47
3 13 1916.12 20 13.33 3034 809 2.61 / 62.28 5 56
4 13 1366.56 20 13.69 2279 624 3.23 / 62.91 5 72
5 13 913.00 20 13.97 1650 461 3.69 / 63.37 5 85
6 13 111.76 20 14.67 440 129 3.82 / 63.50 5 76
7 8 0.00 270 14.45 267 1042 4.86 / 64.54 5 139
Average= 4.30
(KJ/cycle)

Cycle 13 GMT 17/ 1/2018 1:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 26 14.83 407 157 0.16 / 55.08 6 21
2 7 2002.48 41 13.06 3136 1679 1.84 / 56.76 5 47
3 13 1808.04 20 13.41 2881 773 2.61 / 57.53 5 60
4 13 1090.76 20 13.85 1910 529 3.14 / 58.06 5 78
5 13 875.20 20 13.99 1593 446 3.58 / 58.51 5 83
6 13 99.52 20 14.70 419 123 3.71 / 58.63 5 70
7 8 0.08 270 14.48 268 1048 4.75 / 59.68 5 140
Average= 4.26
(KJ/cycle)

Cycle 12 GMT 7/ 1/2018 2: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 26 14.83 405 156 0.16 / 50.29 6 20
2 7 2004.32 40 13.07 3142 1643 1.80 / 51.93 5 48
3 13 1908.64 20 13.33 3035 809 2.61 / 52.74 5 57
4 13 1395.68 20 13.69 2335 639 3.25 / 53.38 5 73
5 13 733.32 20 14.12 1386 391 3.64 / 53.77 5 83
6 13 81.52 20 14.74 389 115 3.75 / 53.89 5 69
7 8 0.00 270 14.49 265 1037 4.79 / 54.92 5 134
Average= 4.22
(KJ/cycle)

Cycle 11 GMT 28/12/2017 2:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 26 14.80 410 158 0.16 / 45.51 6 21
2 7 2003.88 40 13.06 3149 1645 1.80 / 47.16 5 48
3 13 1914.00 20 13.32 3037 809 2.61 / 47.96 5 57
4 13 1376.72 20 13.67 2306 630 3.24 / 48.60 5 73
5 13 716.96 20 14.11 1369 386 3.63 / 48.98 5 84
6 13 80.20 20 14.75 387 114 3.74 / 49.10 5 67
7 8 0.12 271 14.50 264 1037 4.78 / 50.13 5 139
Average= 4.18
(KJ/cycle)

Cycle 10 GMT 18/12/2017 3:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 25 14.84 404 150 0.15 / 40.65 6 22
2 7 2006.16 40 13.06 3159 1650 1.80 / 42.30 5 49
3 13 1920.40 20 13.32 3052 813 2.61 / 43.11 5 57
4 13 1290.64 20 13.72 2178 598 3.21 / 43.71 5 76
5 13 864.80 20 14.00 1567 439 3.65 / 44.15 5 85
6 13 182.20 20 14.63 540 158 3.81 / 44.30 5 73
7 8 0.00 272 14.50 266 1049 4.86 / 45.35 5 136
Average= 4.12
(KJ/cycle)

Cycle 9 GMT 8/12/2017 3:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 25 14.84 419 155 0.16 / 35.90 6 22
2 7 2005.16 40 13.06 3144 1642 1.80 / 37.54 22 48
3 13 1912.12 20 13.32 3049 812 2.61 / 38.35 5 58
4 13 1370.40 20 13.68 2280 624 3.23 / 38.98 5 72
5 13 727.92 20 14.09 1376 388 3.62 / 39.36 5 87
6 13 41.72 20 14.80 329 97 3.72 / 39.46 5 69
7 8 0.00 270 14.48 265 1036 4.76 / 40.50 5 137
Average= 4.05
(KJ/cycle)

Cycle 8 GMT 28/11/2017 4:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 25 14.85 408 151 0.15 / 30.95 6 19
2 7 2003.52 40 13.04 3153 1645 1.80 / 32.59 5 50
3 13 1807.96 20 13.40 2904 778 2.57 / 33.37 5 62
4 13 1501.20 20 13.61 2455 668 3.24 / 34.04 5 69
5 13 1025.12 20 13.88 1804 501 3.74 / 34.54 5 85
6 13 197.60 20 14.60 571 167 3.91 / 34.71 5 78
7 8 0.00 268 14.48 267 1036 4.95 / 35.74 5 130
Average= 3.97
(KJ/cycle)

Cycle 7 GMT 18/11/2017 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 25 14.86 410 152 0.15 / 26.20 6 16
2 7 2006.88 40 13.02 3164 1648 1.80 / 27.84 16 50
3 13 1911.64 20 13.31 3023 805 2.60 / 28.65 5 58
4 13 1283.84 20 13.70 2155 590 3.20 / 29.24 5 75
5 13 747.68 20 14.05 1406 395 3.59 / 29.63 5 89
6 13 90.44 20 14.72 410 121 3.71 / 29.76 5 76
7 8 -0.16 268 14.47 268 1039 4.75 / 30.79 5 132
Average= 3.85
(KJ/cycle)

Cycle 6 GMT 8/11/2017 5:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 25 14.86 417 155 0.15 / 21.40 6 15
2 3 1024.20 1 14.49 1865 27 0.18 / 21.43 5 5
3 7 2008.16 40 13.02 3163 1647 1.83 / 23.08 5 49
4 13 1915.88 20 13.28 3039 807 2.64 / 23.88 5 58
5 13 1277.52 20 13.70 2157 591 3.23 / 24.47 5 76
6 13 634.72 20 14.12 1249 353 3.58 / 24.83 5 90
7 13 186.80 20 14.58 565 165 3.74 / 24.99 5 83
8 8 0.00 268 14.45 272 1053 4.80 / 26.04 5 129
Average= 3.72
(KJ/cycle)

Cycle 5 GMT 29/10/2017 6:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 31 14.84 404 186 0.19 / 16.57 6 13
2 3 761.64 -4 14.84 404 0 0.00 / 16.57 6 13
3 7 2004.92 40 12.99 3154 1639 1.82 / 18.21 13 49
4 13 1920.56 20 13.26 3061 812 2.64 / 19.02 5 57
5 13 1279.84 20 13.68 2158 590 3.23 / 19.61 5 76
6 13 943.00 20 13.88 1688 469 3.70 / 20.08 5 86
7 13 73.12 20 14.74 389 115 3.81 / 20.19 5 74
8 8 -0.12 270 14.46 270 1054 4.86 / 21.25 5 133
Average= 3.54
(KJ/cycle)

Cycle 4 GMT 19/10/2017 6:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 25 14.88 407 151 0.15 / 12.36 6 14
2 7 1509.40 40 13.39 2485 1331 1.48 / 13.69 14 57
3 13 1438.16 20 13.58 2404 653 2.14 / 14.35 5 63
4 13 1126.40 20 13.75 1964 540 2.68 / 14.89 5 76
5 13 665.12 20 14.10 1292 364 3.04 / 15.25 5 85
6 13 36.60 20 14.82 326 97 3.14 / 15.35 5 73
7 8 -0.24 268 14.46 267 1035 4.17 / 16.38 5 138
Average= 3.28
(KJ/cycle)

Cycle 3 GMT 18/10/2017 7:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 25 14.81 410 152 0.15 / 8.23 6 14
2 7 1500.76 40 13.34 2479 1323 1.47 / 9.56 14 56
3 13 1426.28 20 13.54 2390 647 2.12 / 10.20 5 63
4 13 1220.24 20 13.68 2084 570 2.69 / 10.77 5 72
5 13 553.88 20 14.19 1125 319 3.01 / 11.09 5 84
6 13 42.88 20 14.78 337 100 3.11 / 11.19 5 72
7 8 -0.08 265 14.45 266 1019 4.13 / 12.21 5 138
Average= 3.05
(KJ/cycle)

Cycle 2 GMT 17/10/2017 7:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 31 14.71 409 187 0.19 / 4.27 6 13
2 3 769.04 -4 14.71 409 0 0.00 / 4.27 6 13
3 7 1447.72 40 13.25 2410 1277 1.46 / 5.55 13 55
4 13 1369.28 20 13.50 2294 619 2.08 / 6.17 5 62
5 13 1169.52 20 13.65 2014 550 2.63 / 6.72 5 73
6 13 402.24 20 14.31 896 256 2.89 / 6.98 5 80
7 13 34.36 20 14.75 323 95 2.98 / 7.07 5 72
8 8 0.04 265 14.42 264 1009 3.99 / 8.08 5 137
Average= 2.69
(KJ/cycle)

Cycle 1 GMT 16/10/2017 8:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 31 14.71 393 179 0.18 / 1.70 6 11
2 3 770.08 -4 14.71 393 0 0.00 / 1.70 6 11
3 7 928.20 40 13.53 1644 890 1.07 / 2.59 11 54
4 13 716.08 20 13.91 1357 378 1.45 / 2.97 5 65
5 13 57.12 20 14.64 358 105 1.55 / 3.08 5 65
6 8 -0.08 270 14.40 260 1011 2.56 / 4.09 5 137
Average= 2.04
(KJ/cycle)

Cycle 0 GMT 15/10/2017 21:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 90.36 30 14.42 380 164 0.16 / 0.16 6 17
2 7 102.04 41 14.36 389 229 0.39 / 0.39 17 21
3 13 107.56 20 14.55 400 116 0.51 / 0.51 6 24
4 13 73.00 20 14.63 349 102 0.61 / 0.61 6 27
5 8 0.16 268 14.51 235 914 1.53 / 1.53 6 134
Average= 1.53
(KJ/cycle)