SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 64 | 13.82 | 465 | 411 | 0.41 / 1633.59 | 5 | 9 |
2 | 7 | 1119.20 | 80 | 7.77 | 1989 | 1236 | 1.65 / 1634.83 | 5 | 22 |
3 | 13 | 708.96 | 20 | 12.13 | 1443 | 350 | 2.00 / 1635.18 | 5 | 75 |
4 | 13 | 97.60 | 20 | 13.76 | 487 | 134 | 2.13 / 1635.31 | 5 | 87 |
5 | 13 | 26.48 | 20 | 13.97 | 358 | 100 | 2.23 / 1635.41 | 5 | 80 |
6 | 8 | -0.40 | 230 | 13.55 | 304 | 947 | 3.18 / 1636.36 | 5 | 133 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 63 | 13.86 | 470 | 410 | 0.41 / 1630.29 | 5 | 11 |
2 | 3 | 1029.24 | 1 | 11.35 | 1932 | 22 | 0.43 / 1630.31 | 5 | 5 |
3 | 7 | 1131.48 | 80 | 8.15 | 2021 | 1318 | 1.75 / 1631.63 | 5 | 27 |
4 | 13 | 610.56 | 20 | 12.67 | 1300 | 329 | 2.08 / 1631.96 | 5 | 85 |
5 | 13 | 88.12 | 20 | 13.89 | 489 | 136 | 2.22 / 1632.09 | 5 | 86 |
6 | 13 | 21.76 | 20 | 14.08 | 366 | 103 | 2.32 / 1632.20 | 5 | 81 |
7 | 8 | -0.36 | 226 | 13.68 | 319 | 986 | 3.30 / 1633.18 | 5 | 144 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 63 | 14.00 | 466 | 411 | 0.41 / 1626.94 | 5 | 11 |
2 | 3 | 1022.84 | 1 | 11.30 | 1926 | 22 | 0.43 / 1626.97 | 5 | 5 |
3 | 7 | 1134.56 | 81 | 8.92 | 2033 | 1469 | 1.90 / 1628.43 | 5 | 34 |
4 | 13 | 471.40 | 20 | 13.17 | 1085 | 286 | 2.19 / 1628.72 | 5 | 89 |
5 | 13 | 63.36 | 20 | 14.02 | 434 | 122 | 2.31 / 1628.84 | 5 | 86 |
6 | 8 | -0.40 | 237 | 13.75 | 318 | 1036 | 3.35 / 1629.88 | 5 | 139 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 63 | 13.98 | 461 | 406 | 0.41 / 1616.87 | 5 | 11 |
2 | 7 | 1832.68 | 81 | 4.89 | 2980 | 1180 | 1.59 / 1618.05 | 5 | 5 |
3 | 13 | 1964.16 | 20 | 9.53 | 3264 | 622 | 2.21 / 1618.67 | 5 | 5 |
4 | 13 | 2069.88 | 20 | 9.77 | 3424 | 669 | 2.88 / 1619.34 | 5 | 8 |
5 | 13 | 2159.20 | 20 | 9.98 | 3547 | 708 | 3.59 / 1620.05 | 5 | 12 |
6 | 13 | 2225.04 | 20 | 10.10 | 3676 | 743 | 4.33 / 1620.79 | 5 | 14 |
7 | 13 | 2255.36 | 20 | 10.32 | 3712 | 766 | 5.09 / 1621.55 | 5 | 17 |
8 | 13 | 2209.64 | 20 | 10.57 | 3651 | 772 | 5.87 / 1622.33 | 5 | 22 |
9 | 13 | 2135.92 | 20 | 10.76 | 3538 | 761 | 6.63 / 1623.09 | 5 | 28 |
10 | 13 | 2042.32 | 20 | 10.96 | 3400 | 745 | 7.37 / 1623.83 | 5 | 34 |
11 | 13 | 1632.04 | 20 | 12.05 | 2816 | 679 | 8.05 / 1624.51 | 5 | 57 |
12 | 13 | 1101.16 | 20 | 12.71 | 2046 | 520 | 8.57 / 1625.03 | 5 | 79 |
13 | 13 | 659.64 | 20 | 13.26 | 1353 | 359 | 8.93 / 1625.39 | 5 | 91 |
14 | 13 | 48.44 | 20 | 14.11 | 407 | 115 | 9.05 / 1625.51 | 5 | 85 |
15 | 8 | -0.32 | 235 | 13.87 | 315 | 1027 | 10.07 / 1626.53 | 5 | 137 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 63 | 14.02 | 452 | 399 | 0.40 / 1613.69 | 5 | 11 |
2 | 7 | 1116.00 | 81 | 7.95 | 1978 | 1274 | 1.67 / 1614.96 | 5 | 25 |
3 | 13 | 591.28 | 20 | 12.89 | 1265 | 326 | 2.00 / 1615.29 | 5 | 87 |
4 | 13 | 84.32 | 20 | 13.95 | 475 | 133 | 2.13 / 1615.42 | 5 | 85 |
5 | 8 | -0.28 | 239 | 13.92 | 312 | 1038 | 3.17 / 1616.46 | 5 | 134 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 63 | 14.01 | 456 | 402 | 0.40 / 1610.50 | 5 | 13 |
2 | 7 | 1104.08 | 80 | 8.33 | 1970 | 1313 | 1.72 / 1611.81 | 13 | 29 |
3 | 13 | 562.40 | 20 | 13.00 | 1228 | 319 | 2.03 / 1612.13 | 5 | 89 |
4 | 13 | 62.28 | 20 | 14.06 | 422 | 119 | 2.15 / 1612.25 | 5 | 85 |
5 | 13 | 14.76 | 20 | 14.17 | 345 | 98 | 2.25 / 1612.35 | 5 | 81 |
6 | 8 | -0.32 | 216 | 13.97 | 312 | 941 | 3.19 / 1613.29 | 5 | 139 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 63 | 14.11 | 458 | 407 | 0.41 / 1607.23 | 5 | 11 |
2 | 7 | 1114.36 | 80 | 8.97 | 1997 | 1433 | 1.84 / 1608.66 | 5 | 36 |
3 | 13 | 449.16 | 20 | 13.33 | 1048 | 279 | 2.12 / 1608.94 | 5 | 92 |
4 | 13 | 53.88 | 20 | 14.09 | 414 | 117 | 2.24 / 1609.06 | 5 | 85 |
5 | 8 | -0.40 | 235 | 13.96 | 318 | 1043 | 3.28 / 1610.10 | 5 | 151 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 62 | 14.02 | 472 | 410 | 0.41 / 1597.40 | 5 | 14 |
2 | 3 | 1030.80 | 1 | 11.15 | 1924 | 21 | 0.43 / 1597.42 | 5 | 5 |
3 | 7 | 1831.88 | 80 | 4.93 | 3194 | 1260 | 1.69 / 1598.68 | 5 | 5 |
4 | 13 | 1961.32 | 20 | 10.46 | 3282 | 687 | 2.38 / 1599.37 | 5 | 6 |
5 | 13 | 2064.24 | 20 | 10.72 | 3419 | 733 | 3.11 / 1600.10 | 5 | 16 |
6 | 13 | 2147.84 | 20 | 10.93 | 3569 | 780 | 3.89 / 1600.88 | 5 | 23 |
7 | 13 | 2203.92 | 20 | 11.02 | 3660 | 807 | 4.70 / 1601.69 | 5 | 25 |
8 | 13 | 2184.64 | 20 | 11.25 | 3632 | 817 | 5.52 / 1602.51 | 5 | 30 |
9 | 13 | 2120.52 | 20 | 11.48 | 3529 | 810 | 6.33 / 1603.32 | 5 | 37 |
10 | 13 | 2030.96 | 20 | 11.70 | 3401 | 796 | 7.12 / 1604.11 | 5 | 41 |
11 | 13 | 1720.36 | 20 | 12.17 | 2955 | 719 | 7.84 / 1604.83 | 5 | 57 |
12 | 13 | 1082.28 | 20 | 12.81 | 2028 | 520 | 8.36 / 1605.35 | 5 | 82 |
13 | 13 | 547.68 | 20 | 13.38 | 1206 | 323 | 8.68 / 1605.67 | 5 | 95 |
14 | 13 | 53.88 | 20 | 14.11 | 413 | 117 | 8.80 / 1605.79 | 5 | 85 |
15 | 8 | -0.16 | 232 | 14.03 | 316 | 1029 | 9.83 / 1606.82 | 5 | 129 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 63 | 14.07 | 462 | 410 | 0.41 / 1594.11 | 5 | 14 |
2 | 7 | 1120.96 | 80 | 8.16 | 2003 | 1308 | 1.72 / 1595.42 | 5 | 27 |
3 | 13 | 695.48 | 20 | 12.80 | 1440 | 369 | 2.09 / 1595.79 | 5 | 85 |
4 | 13 | 77.72 | 20 | 13.97 | 466 | 130 | 2.22 / 1595.92 | 5 | 84 |
5 | 8 | -0.32 | 239 | 14.01 | 320 | 1071 | 3.29 / 1596.99 | 5 | 135 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 62 | 14.14 | 462 | 405 | 0.41 / 1590.84 | 5 | 18 |
2 | 3 | 1020.12 | 1 | 10.97 | 1923 | 21 | 0.43 / 1590.86 | 5 | 5 |
3 | 7 | 1125.60 | 80 | 8.34 | 1999 | 1334 | 1.76 / 1592.19 | 5 | 28 |
4 | 13 | 591.20 | 20 | 13.04 | 1274 | 332 | 2.09 / 1592.52 | 5 | 89 |
5 | 13 | 81.04 | 20 | 13.99 | 457 | 128 | 2.22 / 1592.65 | 5 | 84 |
6 | 8 | -0.04 | 239 | 14.05 | 313 | 1051 | 3.27 / 1593.70 | 5 | 151 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 62 | 14.17 | 467 | 410 | 0.41 / 1587.47 | 5 | 15 |
2 | 3 | 1040.44 | 1 | 11.43 | 1950 | 22 | 0.43 / 1587.49 | 5 | 10 |
3 | 7 | 1135.88 | 81 | 9.07 | 2034 | 1494 | 1.93 / 1588.98 | 10 | 37 |
4 | 13 | 465.72 | 20 | 13.49 | 1075 | 290 | 2.22 / 1589.27 | 5 | 92 |
5 | 13 | 58.24 | 20 | 14.09 | 432 | 122 | 2.34 / 1589.40 | 5 | 84 |
6 | 8 | -0.36 | 228 | 14.16 | 321 | 1036 | 3.38 / 1590.43 | 5 | 138 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 61 | 14.20 | 457 | 396 | 0.40 / 1577.82 | 5 | 16 |
2 | 3 | 1048.52 | 1 | 11.38 | 1965 | 22 | 0.42 / 1577.85 | 5 | 15 |
3 | 7 | 1829.96 | 81 | 4.88 | 2995 | 1184 | 1.60 / 1579.03 | 15 | 5 |
4 | 13 | 1956.24 | 20 | 10.60 | 3270 | 693 | 2.30 / 1579.72 | 5 | 6 |
5 | 13 | 2057.68 | 20 | 10.79 | 3442 | 743 | 3.04 / 1580.47 | 5 | 18 |
6 | 13 | 2141.08 | 20 | 10.98 | 3569 | 784 | 3.82 / 1581.25 | 5 | 24 |
7 | 13 | 2199.40 | 20 | 11.24 | 3663 | 823 | 4.65 / 1582.07 | 5 | 27 |
8 | 13 | 2179.40 | 20 | 11.37 | 3628 | 825 | 5.47 / 1582.90 | 5 | 32 |
9 | 13 | 2116.32 | 20 | 11.60 | 3544 | 822 | 6.29 / 1583.72 | 5 | 38 |
10 | 13 | 2028.40 | 20 | 11.86 | 3400 | 806 | 7.10 / 1584.53 | 5 | 45 |
11 | 13 | 1417.08 | 20 | 12.62 | 2517 | 635 | 7.73 / 1585.16 | 5 | 69 |
12 | 13 | 1004.28 | 20 | 13.07 | 1890 | 494 | 8.23 / 1585.66 | 5 | 85 |
13 | 13 | 364.64 | 20 | 13.73 | 920 | 253 | 8.48 / 1585.91 | 5 | 94 |
14 | 13 | 67.36 | 20 | 14.15 | 446 | 126 | 8.61 / 1586.04 | 5 | 86 |
15 | 8 | -0.04 | 225 | 14.20 | 320 | 1022 | 9.63 / 1587.06 | 5 | 129 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 62 | 14.15 | 458 | 402 | 0.40 / 1574.63 | 5 | 18 |
2 | 7 | 1095.72 | 80 | 7.93 | 1945 | 1234 | 1.64 / 1575.86 | 18 | 24 |
3 | 13 | 773.04 | 20 | 12.74 | 1534 | 391 | 2.03 / 1576.25 | 5 | 83 |
4 | 13 | 106.68 | 20 | 14.06 | 498 | 140 | 2.17 / 1576.39 | 5 | 87 |
5 | 8 | -0.24 | 235 | 14.23 | 309 | 1033 | 3.20 / 1577.43 | 5 | 132 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 62 | 14.19 | 456 | 401 | 0.40 / 1571.53 | 5 | 19 |
2 | 7 | 1086.88 | 80 | 8.10 | 1930 | 1251 | 1.65 / 1572.78 | 19 | 26 |
3 | 13 | 559.56 | 20 | 13.25 | 1207 | 320 | 1.97 / 1573.10 | 5 | 90 |
4 | 13 | 64.88 | 20 | 14.14 | 427 | 121 | 2.09 / 1573.22 | 5 | 82 |
5 | 8 | -0.28 | 230 | 14.24 | 309 | 1012 | 3.10 / 1574.23 | 5 | 134 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 62 | 14.30 | 449 | 398 | 0.40 / 1568.31 | 5 | 16 |
2 | 7 | 1116.84 | 80 | 8.70 | 1983 | 1380 | 1.78 / 1569.69 | 5 | 32 |
3 | 13 | 475.16 | 20 | 13.57 | 1077 | 292 | 2.07 / 1569.98 | 5 | 93 |
4 | 13 | 69.04 | 20 | 14.19 | 427 | 121 | 2.19 / 1570.11 | 5 | 87 |
5 | 13 | 15.72 | 20 | 14.31 | 330 | 94 | 2.29 / 1570.20 | 5 | 83 |
6 | 8 | -0.32 | 211 | 14.26 | 307 | 924 | 3.21 / 1571.12 | 5 | 151 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 63 | 14.20 | 449 | 402 | 0.40 / 1558.76 | 5 | 20 |
2 | 3 | 963.44 | -1 | 14.20 | 449 | 0 | 0.00 / 1558.76 | 5 | 20 |
3 | 7 | 1807.00 | 81 | 4.91 | 3125 | 1243 | 1.64 / 1560.00 | 20 | 5 |
4 | 13 | 1939.32 | 20 | 10.83 | 3247 | 703 | 2.35 / 1560.71 | 5 | 9 |
5 | 13 | 2043.56 | 20 | 11.12 | 3423 | 761 | 3.11 / 1561.47 | 5 | 23 |
6 | 13 | 2125.20 | 20 | 11.31 | 3535 | 800 | 3.91 / 1562.27 | 5 | 28 |
7 | 13 | 2178.28 | 20 | 11.42 | 3606 | 824 | 4.73 / 1563.09 | 5 | 30 |
8 | 13 | 2147.24 | 20 | 11.61 | 3581 | 832 | 5.56 / 1563.92 | 5 | 36 |
9 | 13 | 2077.36 | 20 | 11.82 | 3485 | 824 | 6.39 / 1564.75 | 5 | 43 |
10 | 13 | 1984.12 | 20 | 12.06 | 3342 | 806 | 7.19 / 1565.55 | 5 | 49 |
11 | 13 | 1466.04 | 20 | 12.80 | 2544 | 651 | 7.85 / 1566.20 | 5 | 70 |
12 | 13 | 921.76 | 20 | 13.29 | 1758 | 467 | 8.31 / 1566.67 | 5 | 89 |
13 | 13 | 176.00 | 20 | 14.05 | 616 | 173 | 8.49 / 1566.84 | 5 | 94 |
14 | 13 | 19.24 | 20 | 14.25 | 356 | 101 | 8.59 / 1566.94 | 5 | 82 |
15 | 8 | -0.24 | 218 | 14.30 | 311 | 970 | 9.56 / 1567.91 | 5 | 134 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 62 | 14.15 | 460 | 404 | 0.40 / 1555.56 | 5 | 18 |
2 | 7 | 1098.64 | 81 | 8.10 | 1955 | 1283 | 1.69 / 1556.84 | 18 | 26 |
3 | 13 | 661.96 | 20 | 13.06 | 1368 | 357 | 2.04 / 1557.20 | 5 | 90 |
4 | 13 | 96.68 | 20 | 14.06 | 477 | 134 | 2.18 / 1557.33 | 5 | 90 |
5 | 8 | -0.12 | 232 | 14.23 | 311 | 1027 | 3.20 / 1558.36 | 5 | 145 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 62 | 14.24 | 462 | 408 | 0.41 / 1552.39 | 5 | 20 |
2 | 7 | 1079.28 | 81 | 8.33 | 1926 | 1300 | 1.71 / 1553.69 | 20 | 28 |
3 | 13 | 537.92 | 20 | 13.34 | 1175 | 313 | 2.02 / 1554.01 | 5 | 92 |
4 | 13 | 93.40 | 20 | 14.10 | 471 | 133 | 2.15 / 1554.14 | 5 | 88 |
5 | 8 | -0.20 | 230 | 14.25 | 309 | 1013 | 3.17 / 1555.15 | 5 | 135 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 64 | 14.28 | 463 | 423 | 0.42 / 1549.23 | 5 | 17 |
2 | 3 | 938.24 | -1 | 14.28 | 463 | 0 | 0.00 / 1549.23 | 5 | 17 |
3 | 7 | 1092.76 | 80 | 8.82 | 1964 | 1386 | 1.81 / 1550.61 | 17 | 34 |
4 | 13 | 440.76 | 20 | 13.64 | 1026 | 280 | 2.09 / 1550.89 | 5 | 94 |
5 | 13 | 50.88 | 20 | 14.20 | 398 | 113 | 2.20 / 1551.01 | 5 | 85 |
6 | 8 | -0.24 | 223 | 14.29 | 308 | 981 | 3.18 / 1551.99 | 5 | 132 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 63 | 14.19 | 472 | 422 | 0.42 / 1540.48 | 5 | 20 |
2 | 7 | 1807.60 | 80 | 5.70 | 3007 | 1371 | 1.79 / 1541.85 | 20 | 5 |
3 | 13 | 1921.28 | 20 | 11.03 | 3242 | 715 | 2.51 / 1542.57 | 5 | 26 |
4 | 13 | 2005.16 | 20 | 11.34 | 3353 | 760 | 3.27 / 1543.33 | 5 | 31 |
5 | 13 | 2059.72 | 20 | 11.53 | 3430 | 791 | 4.06 / 1544.12 | 5 | 35 |
6 | 13 | 2035.00 | 20 | 11.78 | 3398 | 801 | 4.86 / 1544.92 | 5 | 40 |
7 | 13 | 1965.52 | 20 | 12.00 | 3317 | 796 | 5.66 / 1545.72 | 5 | 47 |
8 | 13 | 1870.20 | 20 | 12.23 | 3188 | 780 | 6.44 / 1546.50 | 5 | 54 |
9 | 13 | 1442.12 | 20 | 12.83 | 2536 | 651 | 7.09 / 1547.15 | 5 | 72 |
10 | 13 | 790.76 | 20 | 13.41 | 1567 | 420 | 7.51 / 1547.57 | 5 | 92 |
11 | 13 | 142.16 | 20 | 14.05 | 585 | 164 | 7.67 / 1547.73 | 5 | 92 |
12 | 8 | -0.20 | 235 | 14.30 | 319 | 1072 | 8.74 / 1548.80 | 5 | 129 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 64 | 14.18 | 480 | 436 | 0.44 / 1537.23 | 5 | 21 |
2 | 3 | 951.04 | -1 | 14.18 | 480 | 0 | 0.00 / 1537.23 | 5 | 21 |
3 | 7 | 1104.48 | 81 | 8.24 | 1972 | 1316 | 1.75 / 1538.55 | 21 | 28 |
4 | 13 | 568.88 | 20 | 13.32 | 1236 | 329 | 2.08 / 1538.88 | 5 | 92 |
5 | 13 | 64.20 | 20 | 14.12 | 437 | 123 | 2.20 / 1539.00 | 5 | 84 |
6 | 8 | -0.20 | 230 | 14.24 | 323 | 1058 | 3.26 / 1540.06 | 5 | 137 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 62 | 14.16 | 501 | 440 | 0.44 / 1533.82 | 5 | 20 |
2 | 3 | 1064.36 | 2 | 11.50 | 1987 | 46 | 0.49 / 1533.86 | 5 | 27 |
3 | 7 | 1148.36 | 80 | 8.24 | 2035 | 1341 | 1.83 / 1535.20 | 27 | 27 |
4 | 13 | 716.88 | 20 | 13.18 | 1444 | 381 | 2.21 / 1535.58 | 5 | 89 |
5 | 13 | 88.24 | 20 | 14.11 | 478 | 135 | 2.34 / 1535.72 | 5 | 83 |
6 | 8 | 0.12 | 235 | 14.26 | 322 | 1079 | 3.42 / 1536.80 | 5 | 133 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 63 | 14.21 | 479 | 429 | 0.43 / 1530.42 | 5 | 17 |
2 | 3 | 1032.44 | 1 | 11.34 | 1932 | 22 | 0.45 / 1530.44 | 5 | 6 |
3 | 7 | 1134.76 | 81 | 8.70 | 2024 | 1426 | 1.88 / 1531.87 | 6 | 33 |
4 | 13 | 573.00 | 20 | 13.53 | 1243 | 336 | 2.21 / 1532.20 | 5 | 94 |
5 | 13 | 62.88 | 20 | 14.18 | 425 | 121 | 2.33 / 1532.32 | 5 | 84 |
6 | 8 | -0.28 | 230 | 14.27 | 321 | 1054 | 3.39 / 1533.38 | 5 | 133 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 63 | 14.19 | 459 | 410 | 0.41 / 1521.76 | 5 | 18 |
2 | 7 | 1807.92 | 80 | 5.80 | 3001 | 1392 | 1.80 / 1523.15 | 18 | 5 |
3 | 13 | 1918.96 | 20 | 11.27 | 3220 | 726 | 2.53 / 1523.88 | 5 | 29 |
4 | 13 | 1997.04 | 20 | 11.52 | 3329 | 767 | 3.30 / 1524.65 | 5 | 35 |
5 | 13 | 2045.04 | 20 | 11.67 | 3422 | 799 | 4.09 / 1525.45 | 5 | 38 |
6 | 13 | 2007.12 | 20 | 11.92 | 3372 | 804 | 4.90 / 1526.25 | 5 | 44 |
7 | 13 | 1933.12 | 20 | 12.11 | 3274 | 793 | 5.69 / 1527.04 | 5 | 50 |
8 | 13 | 1836.72 | 20 | 12.35 | 3145 | 777 | 6.47 / 1527.82 | 5 | 57 |
9 | 13 | 1306.00 | 20 | 12.98 | 2345 | 609 | 7.08 / 1528.43 | 5 | 77 |
10 | 13 | 557.68 | 20 | 13.66 | 1226 | 335 | 7.41 / 1528.76 | 5 | 97 |
11 | 13 | 68.28 | 20 | 14.18 | 451 | 128 | 7.54 / 1528.89 | 5 | 84 |
12 | 13 | 44.68 | 20 | 14.23 | 401 | 114 | 7.65 / 1529.00 | 5 | 82 |
13 | 8 | -0.08 | 214 | 14.32 | 321 | 984 | 8.64 / 1529.99 | 5 | 140 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 62 | 14.20 | 452 | 398 | 0.40 / 1518.47 | 5 | 19 |
2 | 3 | 1034.92 | 1 | 11.18 | 1937 | 22 | 0.42 / 1518.49 | 5 | 5 |
3 | 7 | 1130.48 | 80 | 8.20 | 2003 | 1314 | 1.73 / 1519.80 | 5 | 27 |
4 | 13 | 703.72 | 20 | 13.13 | 1444 | 379 | 2.11 / 1520.18 | 5 | 88 |
5 | 13 | 79.36 | 20 | 14.12 | 453 | 128 | 2.24 / 1520.31 | 5 | 84 |
6 | 8 | -0.04 | 235 | 14.26 | 310 | 1039 | 3.28 / 1521.35 | 5 | 137 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 63 | 14.26 | 454 | 408 | 0.41 / 1515.26 | 5 | 18 |
2 | 3 | 965.44 | -1 | 14.26 | 454 | 0 | 0.00 / 1515.26 | 5 | 18 |
3 | 7 | 1115.32 | 81 | 8.42 | 1977 | 1348 | 1.76 / 1516.61 | 18 | 30 |
4 | 13 | 577.00 | 20 | 13.39 | 1240 | 332 | 2.09 / 1516.94 | 5 | 93 |
5 | 13 | 67.60 | 20 | 14.16 | 430 | 122 | 2.21 / 1517.06 | 5 | 82 |
6 | 8 | -0.16 | 230 | 14.28 | 308 | 1012 | 3.22 / 1518.07 | 5 | 137 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 63 | 14.30 | 455 | 410 | 0.41 / 1512.02 | 5 | 15 |
2 | 7 | 1118.12 | 80 | 8.77 | 1987 | 1394 | 1.80 / 1513.41 | 5 | 34 |
3 | 13 | 472.84 | 20 | 13.69 | 1080 | 296 | 2.10 / 1513.71 | 5 | 93 |
4 | 13 | 68.52 | 20 | 14.13 | 434 | 123 | 2.22 / 1513.83 | 5 | 83 |
5 | 8 | -0.20 | 231 | 14.29 | 308 | 1017 | 3.24 / 1514.85 | 5 | 152 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 63 | 14.18 | 462 | 413 | 0.41 / 1503.29 | 5 | 16 |
2 | 7 | 1822.20 | 81 | 5.85 | 3005 | 1424 | 1.84 / 1504.72 | 16 | 5 |
3 | 13 | 1938.96 | 20 | 11.36 | 3264 | 742 | 2.58 / 1505.46 | 5 | 29 |
4 | 13 | 2022.48 | 20 | 11.63 | 3389 | 788 | 3.37 / 1506.25 | 5 | 35 |
5 | 13 | 2075.36 | 20 | 11.75 | 3474 | 816 | 4.18 / 1507.06 | 5 | 37 |
6 | 13 | 2040.72 | 20 | 12.00 | 3418 | 820 | 5.00 / 1507.88 | 5 | 44 |
7 | 13 | 1965.44 | 20 | 12.20 | 3327 | 812 | 5.82 / 1508.70 | 5 | 51 |
8 | 13 | 1771.52 | 20 | 12.60 | 3023 | 762 | 6.58 / 1509.46 | 5 | 62 |
9 | 13 | 1252.56 | 20 | 13.08 | 2266 | 593 | 7.17 / 1510.05 | 5 | 81 |
10 | 13 | 710.56 | 20 | 13.55 | 1438 | 390 | 7.56 / 1510.44 | 5 | 93 |
11 | 13 | 81.12 | 20 | 14.16 | 463 | 131 | 7.69 / 1510.57 | 5 | 85 |
12 | 8 | -0.16 | 233 | 14.34 | 311 | 1039 | 8.73 / 1511.61 | 5 | 145 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 63 | 14.18 | 479 | 428 | 0.43 / 1500.13 | 5 | 17 |
2 | 7 | 1104.16 | 81 | 8.27 | 1958 | 1312 | 1.74 / 1501.44 | 17 | 28 |
3 | 13 | 571.68 | 20 | 13.34 | 1223 | 326 | 2.07 / 1501.76 | 5 | 92 |
4 | 13 | 70.56 | 20 | 14.11 | 425 | 120 | 2.19 / 1501.88 | 5 | 84 |
5 | 8 | -0.12 | 230 | 14.26 | 304 | 997 | 3.18 / 1502.88 | 5 | 133 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 63 | 14.25 | 470 | 422 | 0.42 / 1496.94 | 5 | 17 |
2 | 7 | 1082.00 | 80 | 8.47 | 1927 | 1306 | 1.73 / 1498.24 | 17 | 32 |
3 | 13 | 539.72 | 20 | 13.44 | 1183 | 318 | 2.05 / 1498.56 | 5 | 93 |
4 | 13 | 56.24 | 20 | 14.14 | 413 | 117 | 2.16 / 1498.68 | 5 | 84 |
5 | 8 | -0.04 | 230 | 14.25 | 311 | 1019 | 3.18 / 1499.70 | 5 | 139 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 62 | 14.27 | 466 | 412 | 0.41 / 1493.57 | 5 | 15 |
2 | 3 | 1021.48 | 1 | 10.88 | 1899 | 21 | 0.43 / 1493.59 | 5 | 5 |
3 | 7 | 1128.04 | 80 | 8.76 | 2023 | 1418 | 1.85 / 1495.00 | 5 | 35 |
4 | 13 | 581.04 | 20 | 13.60 | 1241 | 338 | 2.19 / 1495.34 | 5 | 94 |
5 | 13 | 67.64 | 20 | 14.12 | 441 | 125 | 2.31 / 1495.47 | 5 | 84 |
6 | 8 | -0.32 | 230 | 14.28 | 320 | 1051 | 3.36 / 1496.52 | 5 | 136 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 62 | 14.17 | 470 | 413 | 0.41 / 1484.17 | 5 | 14 |
2 | 3 | 1019.60 | 1 | 10.54 | 1920 | 20 | 0.43 / 1484.19 | 5 | 5 |
3 | 7 | 1827.16 | 80 | 5.14 | 3181 | 1308 | 1.74 / 1485.50 | 5 | 5 |
4 | 13 | 1953.48 | 20 | 11.49 | 3293 | 757 | 2.50 / 1486.26 | 5 | 20 |
5 | 13 | 2051.56 | 20 | 11.76 | 3425 | 806 | 3.30 / 1487.06 | 5 | 35 |
6 | 13 | 2125.60 | 20 | 11.93 | 3556 | 848 | 4.15 / 1487.91 | 5 | 38 |
7 | 13 | 2158.44 | 20 | 12.05 | 3599 | 867 | 5.02 / 1488.78 | 5 | 42 |
8 | 13 | 2104.16 | 20 | 12.30 | 3516 | 865 | 5.88 / 1489.64 | 5 | 47 |
9 | 13 | 2018.16 | 20 | 12.42 | 3435 | 853 | 6.74 / 1490.50 | 5 | 52 |
10 | 13 | 1609.40 | 20 | 12.89 | 2804 | 723 | 7.46 / 1491.22 | 5 | 69 |
11 | 13 | 1078.28 | 20 | 13.30 | 1997 | 531 | 7.99 / 1491.75 | 5 | 87 |
12 | 13 | 428.96 | 20 | 13.82 | 1010 | 279 | 8.27 / 1492.03 | 5 | 97 |
13 | 13 | 53.28 | 20 | 14.21 | 406 | 115 | 8.39 / 1492.15 | 5 | 85 |
14 | 8 | -0.16 | 225 | 14.34 | 312 | 1007 | 9.39 / 1493.15 | 5 | 140 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 63 | 14.21 | 466 | 417 | 0.42 / 1480.99 | 5 | 14 |
2 | 7 | 1101.76 | 80 | 8.26 | 1964 | 1298 | 1.71 / 1482.29 | 14 | 28 |
3 | 13 | 573.48 | 20 | 13.35 | 1237 | 330 | 2.05 / 1482.62 | 5 | 92 |
4 | 13 | 71.68 | 20 | 14.11 | 440 | 124 | 2.17 / 1482.74 | 5 | 84 |
5 | 13 | 3.12 | 20 | 14.19 | 317 | 90 | 2.26 / 1482.83 | 5 | 79 |
6 | 8 | -0.24 | 212 | 14.24 | 308 | 930 | 3.19 / 1483.76 | 5 | 138 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 63 | 14.24 | 452 | 405 | 0.41 / 1477.81 | 5 | 15 |
2 | 7 | 1081.40 | 80 | 8.46 | 1927 | 1304 | 1.71 / 1479.12 | 15 | 31 |
3 | 13 | 540.12 | 20 | 13.43 | 1179 | 317 | 2.03 / 1479.43 | 5 | 92 |
4 | 13 | 56.92 | 20 | 14.13 | 413 | 117 | 2.14 / 1479.55 | 5 | 81 |
5 | 8 | -0.08 | 230 | 14.25 | 311 | 1019 | 3.16 / 1480.57 | 5 | 135 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 64 | 14.27 | 463 | 423 | 0.42 / 1474.55 | 5 | 14 |
2 | 3 | 950.00 | -1 | 14.27 | 463 | 0 | 0.00 / 1474.55 | 5 | 14 |
3 | 7 | 1097.80 | 81 | 8.83 | 1977 | 1414 | 1.84 / 1475.96 | 14 | 37 |
4 | 13 | 538.40 | 20 | 13.59 | 1185 | 322 | 2.16 / 1476.28 | 5 | 94 |
5 | 13 | 44.28 | 20 | 14.19 | 398 | 113 | 2.27 / 1476.39 | 5 | 86 |
6 | 8 | -0.32 | 228 | 14.26 | 312 | 1014 | 3.29 / 1477.41 | 5 | 143 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 64 | 14.18 | 466 | 423 | 0.42 / 1465.33 | 5 | 13 |
2 | 3 | 956.04 | -1 | 14.18 | 466 | 0 | 0.00 / 1465.33 | 5 | 13 |
3 | 7 | 1829.60 | 80 | 5.54 | 3156 | 1399 | 1.82 / 1466.73 | 13 | 5 |
4 | 13 | 1955.36 | 20 | 11.64 | 3285 | 765 | 2.59 / 1467.49 | 5 | 29 |
5 | 13 | 2048.44 | 20 | 11.92 | 3421 | 816 | 3.40 / 1468.31 | 5 | 38 |
6 | 13 | 2115.48 | 20 | 12.08 | 3527 | 852 | 4.25 / 1469.16 | 5 | 41 |
7 | 13 | 2107.76 | 20 | 12.24 | 3519 | 861 | 5.12 / 1470.02 | 5 | 47 |
8 | 13 | 2043.32 | 20 | 12.43 | 3439 | 855 | 5.97 / 1470.88 | 5 | 52 |
9 | 13 | 1951.12 | 20 | 12.63 | 3289 | 831 | 6.80 / 1471.71 | 5 | 57 |
10 | 13 | 1525.52 | 20 | 13.00 | 2650 | 689 | 7.49 / 1472.40 | 5 | 73 |
11 | 13 | 865.24 | 20 | 13.49 | 1680 | 453 | 7.94 / 1472.85 | 5 | 91 |
12 | 13 | 113.96 | 20 | 14.11 | 530 | 150 | 8.09 / 1473.00 | 5 | 89 |
13 | 13 | 25.24 | 20 | 14.21 | 378 | 107 | 8.20 / 1473.11 | 5 | 84 |
14 | 8 | -0.32 | 218 | 14.30 | 326 | 1016 | 9.22 / 1474.12 | 5 | 133 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 63 | 14.22 | 462 | 414 | 0.41 / 1462.06 | 5 | 12 |
2 | 7 | 1120.72 | 80 | 8.21 | 1995 | 1310 | 1.72 / 1463.37 | 5 | 27 |
3 | 13 | 691.16 | 20 | 13.20 | 1419 | 375 | 2.10 / 1463.75 | 5 | 87 |
4 | 13 | 68.12 | 20 | 14.10 | 443 | 125 | 2.22 / 1463.87 | 5 | 84 |
5 | 8 | -0.36 | 232 | 14.25 | 312 | 1031 | 3.26 / 1464.91 | 5 | 133 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 64 | 14.28 | 457 | 418 | 0.42 / 1458.88 | 5 | 11 |
2 | 3 | 943.16 | -1 | 14.28 | 457 | 0 | 0.00 / 1458.88 | 5 | 11 |
3 | 7 | 1114.44 | 81 | 8.29 | 1985 | 1333 | 1.75 / 1460.21 | 11 | 29 |
4 | 13 | 483.40 | 20 | 13.51 | 1097 | 296 | 2.05 / 1460.51 | 5 | 91 |
5 | 13 | 77.16 | 20 | 14.09 | 447 | 126 | 2.17 / 1460.64 | 5 | 82 |
6 | 8 | -0.24 | 230 | 14.26 | 309 | 1013 | 3.19 / 1461.65 | 5 | 136 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 64 | 14.29 | 465 | 425 | 0.43 / 1455.63 | 6 | 10 |
2 | 7 | 1105.12 | 80 | 8.79 | 1981 | 1393 | 1.82 / 1457.02 | 10 | 36 |
3 | 13 | 552.16 | 20 | 13.61 | 1200 | 327 | 2.14 / 1457.35 | 5 | 94 |
4 | 13 | 62.12 | 20 | 14.16 | 421 | 119 | 2.26 / 1457.47 | 5 | 77 |
5 | 8 | -0.20 | 228 | 14.29 | 306 | 997 | 3.26 / 1458.46 | 5 | 130 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 64 | 14.18 | 453 | 411 | 0.41 / 1446.79 | 5 | 10 |
2 | 7 | 1820.28 | 80 | 5.73 | 3006 | 1378 | 1.79 / 1448.17 | 10 | 5 |
3 | 13 | 1936.88 | 20 | 11.70 | 3262 | 763 | 2.55 / 1448.93 | 5 | 33 |
4 | 13 | 2020.24 | 20 | 12.03 | 3400 | 818 | 3.37 / 1449.75 | 5 | 39 |
5 | 13 | 2074.80 | 20 | 12.18 | 3475 | 847 | 4.22 / 1450.60 | 5 | 42 |
6 | 13 | 2044.88 | 20 | 12.39 | 3424 | 848 | 5.07 / 1451.45 | 5 | 49 |
7 | 13 | 1968.72 | 20 | 12.58 | 3325 | 837 | 5.90 / 1452.28 | 5 | 54 |
8 | 13 | 1776.00 | 20 | 12.82 | 3035 | 778 | 6.68 / 1453.06 | 5 | 63 |
9 | 13 | 1251.68 | 20 | 13.21 | 2266 | 599 | 7.28 / 1453.66 | 5 | 83 |
10 | 13 | 706.44 | 20 | 13.61 | 1446 | 394 | 7.67 / 1454.05 | 5 | 94 |
11 | 13 | 83.20 | 20 | 14.14 | 461 | 130 | 7.80 / 1454.18 | 5 | 78 |
12 | 8 | -0.12 | 232 | 14.36 | 306 | 1019 | 8.82 / 1455.20 | 5 | 139 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 64 | 14.19 | 451 | 410 | 0.41 / 1443.67 | 5 | 11 |
2 | 7 | 1082.12 | 81 | 8.28 | 1931 | 1295 | 1.70 / 1444.97 | 11 | 30 |
3 | 13 | 450.60 | 20 | 13.56 | 1039 | 282 | 1.99 / 1445.25 | 5 | 90 |
4 | 13 | 74.08 | 20 | 14.08 | 440 | 124 | 2.11 / 1445.38 | 5 | 74 |
5 | 8 | 0.00 | 232 | 14.25 | 304 | 1005 | 3.12 / 1446.38 | 5 | 141 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 64 | 14.24 | 465 | 424 | 0.42 / 1440.48 | 6 | 10 |
2 | 7 | 1101.20 | 80 | 8.42 | 1960 | 1320 | 1.74 / 1441.80 | 10 | 31 |
3 | 13 | 559.60 | 20 | 13.43 | 1207 | 324 | 2.07 / 1442.13 | 5 | 91 |
4 | 13 | 112.28 | 20 | 14.07 | 500 | 141 | 2.21 / 1442.27 | 5 | 81 |
5 | 8 | -0.08 | 232 | 14.27 | 301 | 997 | 3.21 / 1443.27 | 5 | 142 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 63 | 14.28 | 449 | 404 | 0.40 / 1437.13 | 6 | 9 |
2 | 3 | 1025.72 | 1 | 10.66 | 1917 | 20 | 0.42 / 1437.15 | 5 | 5 |
3 | 7 | 1129.44 | 81 | 8.83 | 2033 | 1454 | 1.88 / 1438.60 | 5 | 35 |
4 | 13 | 578.96 | 20 | 13.58 | 1256 | 341 | 2.22 / 1438.94 | 5 | 93 |
5 | 13 | 70.68 | 20 | 14.16 | 424 | 120 | 2.34 / 1439.06 | 5 | 75 |
6 | 13 | 1.72 | 20 | 14.24 | 306 | 87 | 2.43 / 1439.15 | 5 | 63 |
7 | 8 | -0.36 | 211 | 14.29 | 302 | 911 | 3.34 / 1440.06 | 5 | 140 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 64 | 14.23 | 452 | 412 | 0.41 / 1428.74 | 6 | 9 |
2 | 7 | 1817.08 | 81 | 6.06 | 2970 | 1458 | 1.87 / 1430.20 | 9 | 5 |
3 | 13 | 1931.12 | 20 | 11.76 | 3260 | 767 | 2.64 / 1430.97 | 5 | 38 |
4 | 13 | 2014.24 | 20 | 12.07 | 3392 | 819 | 3.46 / 1431.79 | 5 | 42 |
5 | 13 | 2058.08 | 20 | 12.27 | 3459 | 849 | 4.30 / 1432.64 | 5 | 45 |
6 | 13 | 2009.72 | 20 | 12.45 | 3390 | 844 | 5.15 / 1433.48 | 5 | 51 |
7 | 13 | 1925.76 | 20 | 12.62 | 3256 | 822 | 5.97 / 1434.30 | 5 | 57 |
8 | 13 | 1508.16 | 20 | 13.02 | 2651 | 690 | 6.66 / 1434.99 | 5 | 72 |
9 | 13 | 876.08 | 20 | 13.47 | 1700 | 458 | 7.12 / 1435.45 | 5 | 91 |
10 | 13 | 237.44 | 20 | 13.98 | 720 | 201 | 7.32 / 1435.65 | 5 | 92 |
11 | 13 | 66.28 | 20 | 14.17 | 425 | 120 | 7.44 / 1435.77 | 5 | 78 |
12 | 8 | -0.28 | 220 | 14.35 | 301 | 950 | 8.39 / 1436.72 | 5 | 130 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 64 | 14.23 | 453 | 413 | 0.41 / 1425.54 | 5 | 10 |
2 | 7 | 1091.68 | 80 | 8.51 | 1949 | 1327 | 1.74 / 1426.86 | 10 | 32 |
3 | 13 | 545.60 | 20 | 13.42 | 1180 | 317 | 2.06 / 1427.18 | 5 | 91 |
4 | 13 | 94.92 | 20 | 14.04 | 470 | 132 | 2.19 / 1427.31 | 5 | 82 |
5 | 13 | 24.08 | 20 | 14.16 | 347 | 98 | 2.29 / 1427.41 | 5 | 74 |
6 | 8 | -0.24 | 213 | 14.23 | 304 | 921 | 3.21 / 1428.33 | 5 | 137 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 64 | 14.24 | 452 | 412 | 0.41 / 1422.40 | 6 | 10 |
2 | 7 | 1079.52 | 80 | 8.78 | 1930 | 1356 | 1.77 / 1423.75 | 10 | 35 |
3 | 13 | 423.20 | 20 | 13.61 | 1007 | 274 | 2.04 / 1424.03 | 5 | 91 |
4 | 13 | 58.04 | 20 | 14.14 | 405 | 115 | 2.16 / 1424.14 | 5 | 75 |
5 | 13 | 14.36 | 20 | 14.20 | 324 | 92 | 2.25 / 1424.23 | 5 | 72 |
6 | 8 | -0.24 | 209 | 14.24 | 299 | 890 | 3.14 / 1425.12 | 5 | 131 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 65 | 14.26 | 451 | 418 | 0.42 / 1419.15 | 6 | 9 |
2 | 3 | 956.44 | -1 | 14.26 | 451 | 0 | 0.00 / 1419.15 | 6 | 9 |
3 | 7 | 1110.28 | 81 | 8.94 | 1987 | 1439 | 1.86 / 1420.59 | 9 | 38 |
4 | 13 | 440.76 | 20 | 13.69 | 1032 | 283 | 2.14 / 1420.87 | 5 | 92 |
5 | 13 | 57.84 | 20 | 14.16 | 413 | 117 | 2.26 / 1420.98 | 5 | 76 |
6 | 8 | -0.28 | 228 | 14.26 | 308 | 1001 | 3.26 / 1421.99 | 5 | 142 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 63 | 14.12 | 449 | 399 | 0.40 / 1410.95 | 5 | 9 |
2 | 3 | 1027.04 | 1 | 10.77 | 1915 | 21 | 0.42 / 1410.97 | 5 | 5 |
3 | 7 | 1829.08 | 81 | 6.68 | 2974 | 1609 | 2.03 / 1412.58 | 5 | 5 |
4 | 13 | 1932.96 | 20 | 11.86 | 3252 | 771 | 2.80 / 1413.35 | 5 | 42 |
5 | 13 | 1998.80 | 20 | 12.18 | 3343 | 814 | 3.61 / 1414.17 | 5 | 44 |
6 | 13 | 1990.04 | 20 | 12.37 | 3333 | 825 | 4.44 / 1414.99 | 5 | 50 |
7 | 13 | 1923.00 | 20 | 12.54 | 3216 | 807 | 5.25 / 1415.80 | 5 | 56 |
8 | 13 | 1829.24 | 20 | 12.70 | 3110 | 790 | 6.04 / 1416.59 | 5 | 61 |
9 | 13 | 1291.20 | 20 | 13.16 | 2309 | 608 | 6.64 / 1417.19 | 5 | 80 |
10 | 13 | 646.44 | 20 | 13.62 | 1346 | 367 | 7.01 / 1417.56 | 5 | 96 |
11 | 13 | 97.64 | 20 | 14.15 | 481 | 136 | 7.15 / 1417.70 | 5 | 83 |
12 | 13 | 26.88 | 20 | 14.21 | 353 | 100 | 7.25 / 1417.80 | 5 | 76 |
13 | 8 | -0.32 | 213 | 14.33 | 305 | 931 | 8.18 / 1418.73 | 5 | 143 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 64 | 14.20 | 455 | 414 | 0.41 / 1407.85 | 5 | 9 |
2 | 7 | 1075.72 | 80 | 9.05 | 1934 | 1400 | 1.81 / 1409.25 | 9 | 40 |
3 | 13 | 311.64 | 20 | 13.72 | 838 | 230 | 2.04 / 1409.48 | 5 | 90 |
4 | 13 | 55.64 | 20 | 14.09 | 405 | 114 | 2.16 / 1409.59 | 5 | 77 |
5 | 8 | -0.28 | 228 | 14.22 | 296 | 960 | 3.12 / 1410.55 | 5 | 149 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 61 | 14.15 | 460 | 397 | 0.40 / 1404.45 | 5 | 9 |
2 | 10 | 1006.32 | 3 | 12.05 | 1897 | 69 | 0.47 / 1404.52 | 5 | 38 |
3 | 3 | 1038.16 | 1 | 11.32 | 1935 | 22 | 0.49 / 1404.54 | 5 | 5 |
4 | 7 | 1144.00 | 81 | 8.94 | 2031 | 1471 | 1.96 / 1406.01 | 5 | 39 |
5 | 13 | 483.64 | 20 | 13.59 | 1092 | 297 | 2.26 / 1406.31 | 5 | 92 |
6 | 13 | 66.56 | 20 | 14.11 | 433 | 122 | 2.38 / 1406.43 | 5 | 83 |
7 | 13 | 3.44 | 20 | 14.19 | 318 | 90 | 2.47 / 1406.52 | 5 | 79 |
8 | 8 | -0.24 | 209 | 14.22 | 306 | 909 | 3.38 / 1407.43 | 5 | 130 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 61 | 14.28 | 445 | 388 | 0.39 / 1401.04 | 6 | 8 |
2 | 10 | 1010.20 | 3 | 12.30 | 1897 | 70 | 0.46 / 1401.11 | 5 | 43 |
3 | 3 | 1028.92 | 1 | 11.01 | 1934 | 21 | 0.48 / 1401.13 | 5 | 5 |
4 | 7 | 1134.32 | 80 | 9.16 | 2032 | 1489 | 1.97 / 1402.62 | 5 | 40 |
5 | 13 | 459.24 | 20 | 13.67 | 1065 | 291 | 2.26 / 1402.91 | 5 | 94 |
6 | 13 | 58.12 | 20 | 14.15 | 419 | 119 | 2.38 / 1403.03 | 5 | 84 |
7 | 13 | 30.28 | 20 | 14.17 | 370 | 105 | 2.48 / 1403.13 | 5 | 82 |
8 | 8 | -0.52 | 209 | 14.22 | 310 | 921 | 3.40 / 1404.06 | 5 | 137 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 61 | 14.13 | 447 | 385 | 0.39 / 1393.13 | 5 | 9 |
2 | 3 | 1095.28 | 2 | 11.56 | 2048 | 47 | 0.43 / 1393.17 | 5 | 41 |
3 | 7 | 1832.40 | 80 | 7.65 | 3033 | 1856 | 2.29 / 1395.03 | 41 | 9 |
4 | 13 | 1922.44 | 20 | 12.14 | 3241 | 787 | 3.08 / 1395.82 | 5 | 48 |
5 | 13 | 1968.08 | 20 | 12.32 | 3335 | 822 | 3.90 / 1396.64 | 5 | 50 |
6 | 13 | 1920.52 | 20 | 12.47 | 3245 | 809 | 4.71 / 1397.45 | 5 | 54 |
7 | 13 | 1837.96 | 20 | 12.58 | 3135 | 789 | 5.50 / 1398.24 | 5 | 60 |
8 | 13 | 1533.36 | 20 | 12.90 | 2667 | 688 | 6.18 / 1398.92 | 5 | 69 |
9 | 13 | 895.28 | 20 | 13.38 | 1725 | 462 | 6.65 / 1399.39 | 5 | 90 |
10 | 13 | 247.52 | 20 | 13.93 | 730 | 203 | 6.85 / 1399.59 | 5 | 95 |
11 | 13 | 40.52 | 20 | 14.18 | 383 | 109 | 6.96 / 1399.70 | 5 | 82 |
12 | 8 | -0.12 | 220 | 14.31 | 303 | 954 | 7.91 / 1400.65 | 5 | 134 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 76 | 14.15 | 461 | 496 | 0.50 / 1390.58 | 5 | 11 |
2 | 3 | 437.52 | -1 | 14.15 | 461 | 0 | 0.00 / 1390.58 | 5 | 11 |
3 | 7 | 600.84 | 80 | 11.41 | 1241 | 1133 | 1.63 / 1391.71 | 11 | 61 |
4 | 13 | 31.36 | 20 | 14.13 | 369 | 104 | 1.73 / 1391.82 | 5 | 80 |
5 | 8 | -0.32 | 213 | 14.15 | 307 | 925 | 2.66 / 1392.74 | 5 | 131 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 72 | 14.15 | 452 | 460 | 0.46 / 1387.80 | 5 | 9 |
2 | 10 | 505.56 | 3 | 13.16 | 1116 | 44 | 0.50 / 1387.84 | 5 | 33 |
3 | 3 | 543.52 | 1 | 12.14 | 1195 | 15 | 0.52 / 1387.85 | 5 | 12 |
4 | 7 | 611.40 | 81 | 11.37 | 1268 | 1168 | 1.69 / 1389.02 | 12 | 60 |
5 | 13 | 33.80 | 20 | 14.13 | 383 | 108 | 1.80 / 1389.13 | 5 | 80 |
6 | 8 | -0.40 | 213 | 14.15 | 316 | 952 | 2.75 / 1390.08 | 5 | 134 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 72 | 14.17 | 467 | 476 | 0.48 / 1385.11 | 6 | 8 |
2 | 10 | 503.24 | 3 | 13.15 | 1119 | 44 | 0.52 / 1385.15 | 5 | 31 |
3 | 3 | 556.88 | 1 | 12.36 | 1192 | 15 | 0.54 / 1385.17 | 5 | 25 |
4 | 7 | 612.80 | 80 | 11.29 | 1256 | 1134 | 1.67 / 1386.30 | 25 | 59 |
5 | 13 | 32.16 | 20 | 14.12 | 373 | 105 | 1.78 / 1386.41 | 5 | 81 |
6 | 8 | -0.44 | 213 | 14.15 | 308 | 928 | 2.70 / 1387.34 | 5 | 131 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 72 | 14.11 | 464 | 471 | 0.47 / 1379.96 | 5 | 9 |
2 | 10 | 509.28 | 3 | 13.05 | 1123 | 44 | 0.52 / 1380.00 | 5 | 33 |
3 | 3 | 552.32 | 1 | 12.46 | 1186 | 15 | 0.53 / 1380.02 | 5 | 22 |
4 | 7 | 1011.64 | 81 | 10.45 | 1873 | 1585 | 2.12 / 1381.60 | 22 | 33 |
5 | 13 | 1087.48 | 20 | 12.92 | 2024 | 523 | 2.64 / 1382.13 | 5 | 60 |
6 | 13 | 1052.08 | 20 | 13.07 | 1965 | 514 | 3.15 / 1382.64 | 5 | 66 |
7 | 13 | 969.96 | 20 | 13.18 | 1839 | 485 | 3.64 / 1383.13 | 5 | 73 |
8 | 13 | 556.76 | 20 | 13.59 | 1208 | 328 | 3.97 / 1383.45 | 5 | 86 |
9 | 13 | 57.44 | 20 | 14.14 | 424 | 120 | 4.09 / 1383.57 | 5 | 81 |
10 | 13 | 31.88 | 20 | 14.17 | 382 | 108 | 4.19 / 1383.68 | 5 | 80 |
11 | 8 | -0.32 | 211 | 14.21 | 317 | 950 | 5.14 / 1384.63 | 5 | 135 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 75 | 14.13 | 456 | 483 | 0.48 / 1377.25 | 5 | 9 |
2 | 3 | 526.72 | 1 | 12.24 | 1152 | 14 | 0.50 / 1377.26 | 5 | 5 |
3 | 7 | 600.88 | 80 | 11.53 | 1244 | 1147 | 1.64 / 1378.41 | 5 | 61 |
4 | 13 | 31.88 | 20 | 14.09 | 383 | 108 | 1.75 / 1378.52 | 5 | 81 |
5 | 8 | -0.36 | 216 | 14.12 | 319 | 973 | 2.73 / 1379.49 | 5 | 141 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 74 | 14.10 | 458 | 478 | 0.48 / 1374.54 | 5 | 11 |
2 | 3 | 533.56 | 1 | 12.00 | 1162 | 14 | 0.49 / 1374.55 | 5 | 6 |
3 | 7 | 600.16 | 80 | 11.34 | 1249 | 1133 | 1.62 / 1375.69 | 6 | 60 |
4 | 13 | 32.92 | 20 | 14.03 | 388 | 109 | 1.73 / 1375.79 | 5 | 81 |
5 | 8 | -0.32 | 216 | 14.13 | 317 | 968 | 2.70 / 1376.76 | 5 | 146 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 88 | 14.13 | 456 | 567 | 0.57 / 1372.15 | 6 | 10 |
2 | 3 | 104.32 | -6 | 14.13 | 456 | 0 | 0.00 / 1372.15 | 6 | 10 |
3 | 7 | 416.92 | 80 | 11.63 | 959 | 892 | 1.46 / 1373.05 | 10 | 55 |
4 | 13 | 22.48 | 20 | 14.09 | 357 | 101 | 1.56 / 1373.15 | 5 | 72 |
5 | 8 | -0.52 | 209 | 14.15 | 309 | 914 | 2.47 / 1374.06 | 5 | 134 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 88 | 14.13 | 453 | 563 | 0.56 / 1366.96 | 5 | 12 |
2 | 3 | 102.92 | -6 | 14.13 | 453 | 0 | 0.00 / 1366.96 | 5 | 12 |
3 | 7 | 1016.64 | 80 | 10.14 | 1856 | 1506 | 2.07 / 1368.47 | 12 | 27 |
4 | 13 | 1099.56 | 20 | 12.83 | 2025 | 520 | 2.59 / 1368.99 | 5 | 54 |
5 | 13 | 1085.24 | 20 | 12.97 | 2008 | 521 | 3.11 / 1369.51 | 5 | 59 |
6 | 13 | 1008.96 | 20 | 13.09 | 1907 | 499 | 3.61 / 1370.01 | 5 | 66 |
7 | 13 | 705.88 | 20 | 13.45 | 1445 | 389 | 4.00 / 1370.40 | 5 | 80 |
8 | 13 | 78.56 | 20 | 14.09 | 459 | 129 | 4.13 / 1370.53 | 5 | 83 |
9 | 13 | 26.56 | 20 | 14.18 | 362 | 103 | 4.23 / 1370.63 | 5 | 78 |
10 | 8 | -0.08 | 216 | 14.23 | 312 | 959 | 5.19 / 1371.59 | 5 | 150 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 79 | 14.07 | 450 | 500 | 0.50 / 1364.27 | 5 | 12 |
2 | 3 | 283.72 | -3 | 14.07 | 450 | 0 | 0.00 / 1364.27 | 5 | 12 |
3 | 7 | 593.68 | 80 | 11.12 | 1226 | 1091 | 1.59 / 1365.36 | 12 | 60 |
4 | 13 | 32.28 | 20 | 14.06 | 369 | 104 | 1.69 / 1365.46 | 5 | 82 |
5 | 8 | -0.36 | 216 | 14.12 | 307 | 936 | 2.63 / 1366.40 | 5 | 132 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 88 | 14.21 | 449 | 561 | 0.56 / 1361.91 | 5 | 10 |
2 | 3 | 94.40 | -6 | 14.21 | 449 | 0 | 0.00 / 1361.91 | 5 | 10 |
3 | 7 | 389.28 | 81 | 12.06 | 913 | 892 | 1.45 / 1362.80 | 10 | 57 |
4 | 13 | 14.60 | 20 | 14.08 | 335 | 94 | 1.55 / 1362.90 | 5 | 73 |
5 | 8 | -0.60 | 204 | 14.12 | 303 | 873 | 2.42 / 1363.77 | 5 | 130 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 63 | 14.29 | 439 | 395 | 0.40 / 1358.53 | 6 | 8 |
2 | 7 | 1093.76 | 81 | 9.46 | 1974 | 1513 | 1.91 / 1360.04 | 8 | 44 |
3 | 13 | 204.12 | 20 | 13.89 | 667 | 185 | 2.09 / 1360.23 | 5 | 94 |
4 | 13 | 43.76 | 20 | 14.12 | 393 | 111 | 2.20 / 1360.34 | 5 | 86 |
5 | 13 | 22.20 | 20 | 14.15 | 355 | 100 | 2.30 / 1360.44 | 5 | 86 |
6 | 8 | -0.56 | 205 | 14.18 | 313 | 910 | 3.21 / 1361.35 | 5 | 144 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 63 | 14.15 | 442 | 394 | 0.39 / 1349.71 | 5 | 10 |
2 | 7 | 2007.20 | 80 | 6.79 | 3241 | 1761 | 2.15 / 1351.47 | 10 | 5 |
3 | 13 | 2109.48 | 20 | 11.79 | 3525 | 831 | 2.99 / 1352.31 | 5 | 38 |
4 | 13 | 2173.04 | 20 | 12.14 | 3627 | 881 | 3.87 / 1353.19 | 5 | 42 |
5 | 13 | 2153.96 | 20 | 12.30 | 3575 | 879 | 4.75 / 1354.07 | 5 | 46 |
6 | 13 | 2085.20 | 20 | 12.47 | 3487 | 870 | 5.62 / 1354.94 | 5 | 52 |
7 | 13 | 1990.76 | 20 | 12.65 | 3330 | 842 | 6.46 / 1355.78 | 5 | 58 |
8 | 13 | 1463.64 | 20 | 13.09 | 2543 | 666 | 7.12 / 1356.44 | 5 | 75 |
9 | 13 | 910.84 | 20 | 13.46 | 1710 | 460 | 7.58 / 1356.90 | 5 | 91 |
10 | 13 | 143.92 | 20 | 14.04 | 565 | 159 | 7.74 / 1357.06 | 5 | 94 |
11 | 13 | 33.68 | 20 | 14.20 | 373 | 106 | 7.85 / 1357.17 | 5 | 88 |
12 | 8 | -0.52 | 218 | 14.32 | 309 | 965 | 8.81 / 1358.13 | 5 | 138 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 63 | 14.15 | 449 | 400 | 0.40 / 1346.60 | 5 | 9 |
2 | 7 | 1089.56 | 80 | 9.41 | 1955 | 1472 | 1.87 / 1348.07 | 9 | 44 |
3 | 13 | 204.28 | 20 | 13.84 | 649 | 180 | 2.05 / 1348.25 | 5 | 93 |
4 | 13 | 43.56 | 20 | 14.03 | 385 | 108 | 2.16 / 1348.36 | 5 | 87 |
5 | 8 | -0.40 | 223 | 14.15 | 304 | 959 | 3.12 / 1349.32 | 5 | 132 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 63 | 14.15 | 446 | 398 | 0.40 / 1343.40 | 5 | 10 |
2 | 7 | 1090.96 | 81 | 9.47 | 1962 | 1505 | 1.90 / 1344.90 | 10 | 45 |
3 | 13 | 288.24 | 20 | 13.76 | 792 | 218 | 2.12 / 1345.12 | 5 | 93 |
4 | 13 | 38.04 | 20 | 14.09 | 385 | 108 | 2.23 / 1345.23 | 5 | 87 |
5 | 8 | -0.40 | 223 | 14.16 | 308 | 973 | 3.20 / 1346.20 | 5 | 138 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 63 | 14.26 | 450 | 404 | 0.40 / 1340.25 | 6 | 9 |
2 | 7 | 1089.04 | 80 | 9.61 | 1961 | 1508 | 1.91 / 1341.75 | 9 | 46 |
3 | 13 | 196.04 | 20 | 13.90 | 650 | 181 | 2.09 / 1341.94 | 5 | 94 |
4 | 13 | 27.28 | 20 | 14.11 | 362 | 102 | 2.19 / 1342.04 | 5 | 82 |
5 | 8 | -0.56 | 221 | 14.18 | 307 | 962 | 3.16 / 1343.00 | 5 | 138 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 63 | 14.09 | 456 | 405 | 0.40 / 1331.53 | 5 | 10 |
2 | 7 | 2009.28 | 80 | 7.06 | 3250 | 1836 | 2.24 / 1333.37 | 5 | 5 |
3 | 13 | 2108.16 | 20 | 11.86 | 3518 | 834 | 3.07 / 1334.20 | 5 | 39 |
4 | 13 | 2165.36 | 20 | 12.15 | 3603 | 876 | 3.95 / 1335.08 | 5 | 41 |
5 | 13 | 2134.28 | 20 | 12.30 | 3587 | 882 | 4.83 / 1335.96 | 5 | 47 |
6 | 13 | 2060.68 | 20 | 12.47 | 3470 | 865 | 5.70 / 1336.83 | 5 | 52 |
7 | 13 | 1864.36 | 20 | 12.74 | 3166 | 807 | 6.50 / 1337.63 | 5 | 61 |
8 | 13 | 1331.64 | 20 | 13.13 | 2366 | 621 | 7.13 / 1338.25 | 5 | 79 |
9 | 13 | 689.80 | 20 | 13.57 | 1404 | 381 | 7.51 / 1338.64 | 5 | 94 |
10 | 13 | 141.84 | 20 | 14.05 | 564 | 158 | 7.67 / 1338.79 | 5 | 94 |
11 | 13 | 30.28 | 20 | 14.19 | 365 | 104 | 7.77 / 1338.90 | 5 | 86 |
12 | 8 | -0.32 | 213 | 14.31 | 310 | 945 | 8.71 / 1339.84 | 5 | 141 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 63 | 14.13 | 458 | 408 | 0.41 / 1328.33 | 5 | 10 |
2 | 7 | 1092.76 | 81 | 9.55 | 1972 | 1525 | 1.93 / 1329.86 | 10 | 46 |
3 | 13 | 186.76 | 20 | 13.89 | 631 | 175 | 2.11 / 1330.03 | 5 | 92 |
4 | 13 | 41.76 | 20 | 14.06 | 388 | 109 | 2.22 / 1330.14 | 5 | 83 |
5 | 8 | -0.40 | 223 | 14.13 | 313 | 986 | 3.20 / 1331.13 | 5 | 134 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 63 | 14.17 | 458 | 409 | 0.41 / 1325.10 | 5 | 10 |
2 | 7 | 1094.96 | 80 | 9.60 | 1974 | 1516 | 1.92 / 1326.62 | 10 | 46 |
3 | 13 | 200.24 | 20 | 13.81 | 673 | 186 | 2.11 / 1326.80 | 5 | 91 |
4 | 13 | 42.28 | 20 | 14.08 | 395 | 111 | 2.22 / 1326.91 | 5 | 83 |
5 | 8 | -0.56 | 225 | 14.13 | 318 | 1011 | 3.23 / 1327.92 | 5 | 147 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 63 | 14.27 | 465 | 418 | 0.42 / 1321.88 | 5 | 9 |
2 | 7 | 1088.44 | 80 | 9.71 | 1968 | 1529 | 1.95 / 1323.41 | 9 | 48 |
3 | 13 | 184.48 | 20 | 13.91 | 643 | 179 | 2.13 / 1323.59 | 5 | 92 |
4 | 13 | 24.16 | 20 | 14.12 | 361 | 102 | 2.23 / 1323.69 | 5 | 81 |
5 | 8 | -0.52 | 223 | 14.17 | 317 | 1002 | 3.23 / 1324.69 | 5 | 142 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 63 | 14.13 | 444 | 395 | 0.40 / 1313.26 | 5 | 11 |
2 | 7 | 2005.60 | 80 | 7.45 | 3240 | 1931 | 2.33 / 1315.19 | 5 | 7 |
3 | 13 | 2090.88 | 20 | 11.93 | 3474 | 829 | 3.16 / 1316.02 | 5 | 40 |
4 | 13 | 2135.16 | 20 | 12.20 | 3556 | 868 | 4.02 / 1316.88 | 5 | 43 |
5 | 13 | 2088.56 | 20 | 12.36 | 3492 | 863 | 4.89 / 1317.75 | 5 | 50 |
6 | 13 | 2003.84 | 20 | 12.52 | 3350 | 839 | 5.72 / 1318.59 | 5 | 54 |
7 | 13 | 1693.64 | 20 | 12.85 | 2885 | 741 | 6.47 / 1319.33 | 5 | 66 |
8 | 13 | 1163.20 | 20 | 13.21 | 2131 | 563 | 7.03 / 1319.89 | 5 | 84 |
9 | 13 | 617.60 | 20 | 13.64 | 1276 | 348 | 7.38 / 1320.24 | 5 | 93 |
10 | 13 | 75.04 | 20 | 14.10 | 469 | 132 | 7.51 / 1320.37 | 5 | 89 |
11 | 13 | 17.52 | 20 | 14.21 | 362 | 103 | 7.61 / 1320.47 | 5 | 86 |
12 | 8 | -0.36 | 211 | 14.29 | 328 | 989 | 8.60 / 1321.46 | 5 | 142 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 63 | 14.16 | 450 | 401 | 0.40 / 1310.04 | 5 | 10 |
2 | 7 | 1109.60 | 80 | 9.74 | 1992 | 1552 | 1.95 / 1311.59 | 5 | 48 |
3 | 13 | 210.56 | 20 | 13.83 | 680 | 188 | 2.14 / 1311.78 | 5 | 93 |
4 | 13 | 45.88 | 20 | 14.06 | 394 | 111 | 2.25 / 1311.89 | 5 | 86 |
5 | 8 | -0.36 | 223 | 14.15 | 307 | 969 | 3.22 / 1312.86 | 5 | 136 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 63 | 14.14 | 455 | 405 | 0.41 / 1306.81 | 5 | 10 |
2 | 7 | 1108.68 | 80 | 9.69 | 1994 | 1546 | 1.95 / 1308.35 | 5 | 47 |
3 | 13 | 207.96 | 20 | 13.84 | 673 | 186 | 2.14 / 1308.54 | 5 | 93 |
4 | 13 | 45.96 | 20 | 14.07 | 396 | 111 | 2.25 / 1308.65 | 5 | 87 |
5 | 8 | -0.44 | 223 | 14.15 | 313 | 988 | 3.24 / 1309.64 | 5 | 133 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 63 | 14.25 | 460 | 413 | 0.41 / 1303.48 | 5 | 10 |
2 | 3 | 1021.44 | 1 | 10.86 | 1925 | 21 | 0.43 / 1303.51 | 5 | 5 |
3 | 7 | 1124.72 | 81 | 9.71 | 2027 | 1594 | 2.03 / 1305.10 | 5 | 47 |
4 | 13 | 221.76 | 20 | 13.87 | 702 | 195 | 2.22 / 1305.29 | 5 | 93 |
5 | 13 | 51.56 | 20 | 14.08 | 412 | 116 | 2.34 / 1305.41 | 5 | 88 |
6 | 8 | -0.52 | 223 | 14.18 | 314 | 993 | 3.33 / 1306.40 | 5 | 132 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 63 | 14.10 | 452 | 402 | 0.40 / 1294.99 | 5 | 11 |
2 | 7 | 2007.64 | 81 | 7.59 | 3252 | 1999 | 2.40 / 1296.99 | 5 | 7 |
3 | 13 | 2086.44 | 20 | 11.99 | 3476 | 834 | 3.23 / 1297.82 | 5 | 41 |
4 | 13 | 2125.40 | 20 | 12.25 | 3536 | 866 | 4.10 / 1298.69 | 5 | 45 |
5 | 13 | 2079.08 | 20 | 12.38 | 3453 | 855 | 4.96 / 1299.54 | 5 | 50 |
6 | 13 | 1988.96 | 20 | 12.57 | 3352 | 843 | 5.80 / 1300.38 | 5 | 56 |
7 | 13 | 1691.48 | 20 | 12.88 | 2835 | 730 | 6.53 / 1301.11 | 5 | 64 |
8 | 13 | 1058.16 | 20 | 13.33 | 1943 | 518 | 7.05 / 1301.63 | 5 | 87 |
9 | 13 | 423.80 | 20 | 13.75 | 1018 | 280 | 7.33 / 1301.91 | 5 | 96 |
10 | 13 | 49.36 | 20 | 14.15 | 413 | 117 | 7.44 / 1302.03 | 5 | 87 |
11 | 8 | -0.40 | 228 | 14.30 | 320 | 1043 | 8.49 / 1303.07 | 5 | 139 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 63 | 14.13 | 451 | 401 | 0.40 / 1291.72 | 5 | 11 |
2 | 7 | 1108.40 | 80 | 9.73 | 2007 | 1562 | 1.96 / 1293.29 | 5 | 48 |
3 | 13 | 205.96 | 20 | 13.84 | 680 | 188 | 2.15 / 1293.47 | 5 | 93 |
4 | 13 | 27.24 | 20 | 14.09 | 382 | 108 | 2.26 / 1293.58 | 5 | 83 |
5 | 8 | -0.36 | 223 | 14.14 | 318 | 1003 | 3.26 / 1294.58 | 5 | 134 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 63 | 14.09 | 450 | 399 | 0.40 / 1288.52 | 5 | 12 |
2 | 7 | 1101.20 | 80 | 9.81 | 1986 | 1559 | 1.96 / 1290.08 | 5 | 48 |
3 | 13 | 193.12 | 20 | 13.84 | 655 | 181 | 2.14 / 1290.26 | 5 | 93 |
4 | 13 | 23.84 | 20 | 14.12 | 357 | 101 | 2.24 / 1290.36 | 5 | 83 |
5 | 8 | -0.36 | 220 | 14.15 | 309 | 962 | 3.20 / 1291.32 | 5 | 129 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 63 | 14.25 | 446 | 400 | 0.40 / 1285.31 | 5 | 11 |
2 | 7 | 1091.60 | 81 | 9.80 | 1983 | 1574 | 1.97 / 1286.88 | 5 | 50 |
3 | 13 | 96.68 | 20 | 14.01 | 491 | 138 | 2.11 / 1287.02 | 5 | 87 |
4 | 13 | 26.32 | 20 | 14.13 | 367 | 104 | 2.22 / 1287.13 | 5 | 81 |
5 | 8 | -0.36 | 221 | 14.15 | 318 | 994 | 3.21 / 1288.12 | 5 | 141 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 63 | 14.08 | 459 | 407 | 0.41 / 1276.65 | 5 | 12 |
2 | 7 | 2008.00 | 81 | 7.70 | 3247 | 2025 | 2.43 / 1278.68 | 5 | 8 |
3 | 13 | 2095.48 | 20 | 12.04 | 3486 | 839 | 3.27 / 1279.52 | 5 | 42 |
4 | 13 | 2137.56 | 20 | 12.29 | 3557 | 874 | 4.15 / 1280.39 | 5 | 44 |
5 | 13 | 2089.56 | 20 | 12.46 | 3481 | 867 | 5.01 / 1281.26 | 5 | 50 |
6 | 13 | 2006.96 | 20 | 12.58 | 3392 | 853 | 5.87 / 1282.11 | 5 | 54 |
7 | 13 | 1699.76 | 20 | 12.89 | 2920 | 753 | 6.62 / 1282.86 | 5 | 64 |
8 | 13 | 1158.64 | 20 | 13.24 | 2125 | 563 | 7.18 / 1283.43 | 5 | 84 |
9 | 13 | 501.36 | 20 | 13.70 | 1146 | 314 | 7.50 / 1283.74 | 5 | 97 |
10 | 13 | 73.84 | 20 | 14.11 | 451 | 127 | 7.62 / 1283.87 | 5 | 90 |
11 | 8 | -0.28 | 228 | 14.29 | 320 | 1043 | 8.67 / 1284.91 | 5 | 136 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 63 | 14.08 | 461 | 409 | 0.41 / 1273.38 | 5 | 13 |
2 | 7 | 1106.44 | 80 | 9.69 | 2006 | 1555 | 1.96 / 1274.94 | 5 | 48 |
3 | 13 | 209.84 | 20 | 13.84 | 694 | 192 | 2.16 / 1275.13 | 5 | 92 |
4 | 13 | 25.08 | 20 | 14.11 | 370 | 104 | 2.26 / 1275.23 | 5 | 81 |
5 | 8 | -0.36 | 223 | 14.14 | 320 | 1009 | 3.27 / 1276.24 | 5 | 138 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 63 | 14.11 | 463 | 412 | 0.41 / 1270.09 | 5 | 13 |
2 | 7 | 1092.64 | 81 | 9.79 | 1981 | 1571 | 1.98 / 1271.66 | 13 | 49 |
3 | 13 | 275.04 | 20 | 13.75 | 789 | 217 | 2.20 / 1271.88 | 5 | 93 |
4 | 13 | 17.56 | 20 | 14.11 | 362 | 102 | 2.30 / 1271.98 | 5 | 83 |
5 | 8 | -0.28 | 220 | 14.14 | 320 | 995 | 3.30 / 1272.97 | 5 | 133 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 63 | 14.17 | 463 | 413 | 0.41 / 1266.83 | 5 | 12 |
2 | 7 | 1086.24 | 80 | 9.90 | 1971 | 1561 | 1.97 / 1268.39 | 12 | 50 |
3 | 13 | 164.24 | 20 | 13.91 | 617 | 172 | 2.15 / 1268.56 | 5 | 93 |
4 | 13 | 34.52 | 20 | 14.07 | 387 | 109 | 2.25 / 1268.67 | 5 | 84 |
5 | 8 | -0.44 | 220 | 14.15 | 323 | 1005 | 3.26 / 1269.68 | 5 | 141 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 63 | 14.05 | 456 | 404 | 0.40 / 1258.29 | 5 | 16 |
2 | 7 | 2006.48 | 81 | 7.95 | 3254 | 2095 | 2.50 / 1260.39 | 16 | 9 |
3 | 13 | 2086.40 | 20 | 12.10 | 3489 | 844 | 3.34 / 1261.23 | 5 | 41 |
4 | 13 | 2118.04 | 20 | 12.29 | 3544 | 871 | 4.21 / 1262.10 | 5 | 45 |
5 | 13 | 2060.76 | 20 | 12.44 | 3464 | 862 | 5.08 / 1262.97 | 5 | 51 |
6 | 13 | 1970.12 | 20 | 12.60 | 3331 | 839 | 5.92 / 1263.81 | 5 | 56 |
7 | 13 | 1655.84 | 20 | 12.91 | 2831 | 731 | 6.65 / 1264.54 | 5 | 66 |
8 | 13 | 913.36 | 20 | 13.40 | 1745 | 468 | 7.11 / 1265.00 | 5 | 90 |
9 | 13 | 380.88 | 20 | 13.75 | 951 | 262 | 7.38 / 1265.27 | 5 | 96 |
10 | 13 | 35.44 | 20 | 14.15 | 390 | 110 | 7.49 / 1265.38 | 5 | 88 |
11 | 8 | -0.36 | 225 | 14.27 | 324 | 1040 | 8.53 / 1266.42 | 5 | 138 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 62 | 14.00 | 458 | 398 | 0.40 / 1255.07 | 5 | 14 |
2 | 7 | 1103.04 | 81 | 9.81 | 1989 | 1580 | 1.98 / 1256.65 | 5 | 50 |
3 | 13 | 182.92 | 20 | 13.88 | 620 | 172 | 2.15 / 1256.82 | 5 | 93 |
4 | 13 | 17.44 | 20 | 14.13 | 337 | 95 | 2.25 / 1256.91 | 5 | 83 |
5 | 8 | -0.20 | 223 | 14.12 | 310 | 976 | 3.22 / 1257.89 | 5 | 138 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 62 | 14.07 | 462 | 403 | 0.40 / 1251.84 | 5 | 16 |
2 | 7 | 1089.28 | 81 | 9.83 | 1973 | 1571 | 1.97 / 1253.41 | 16 | 48 |
3 | 13 | 162.28 | 20 | 13.89 | 597 | 166 | 2.14 / 1253.58 | 5 | 91 |
4 | 13 | 16.28 | 20 | 14.10 | 353 | 100 | 2.24 / 1253.67 | 5 | 82 |
5 | 8 | -0.32 | 220 | 14.12 | 320 | 994 | 3.23 / 1254.67 | 5 | 131 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 63 | 14.18 | 476 | 425 | 0.43 / 1248.62 | 5 | 15 |
2 | 7 | 1086.28 | 80 | 9.93 | 1972 | 1567 | 1.99 / 1250.19 | 15 | 48 |
3 | 13 | 159.44 | 20 | 13.91 | 607 | 169 | 2.16 / 1250.36 | 5 | 91 |
4 | 8 | -0.20 | 239 | 14.15 | 318 | 1075 | 3.24 / 1251.44 | 5 | 133 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 62 | 14.06 | 466 | 406 | 0.41 / 1240.04 | 5 | 17 |
2 | 3 | 1035.72 | 1 | 11.61 | 1940 | 23 | 0.43 / 1240.06 | 5 | 7 |
3 | 7 | 2007.96 | 80 | 8.14 | 3238 | 2109 | 2.54 / 1242.17 | 7 | 9 |
4 | 13 | 2090.52 | 20 | 12.13 | 3493 | 847 | 3.38 / 1243.01 | 5 | 42 |
5 | 13 | 2123.08 | 20 | 12.31 | 3538 | 871 | 4.26 / 1243.89 | 5 | 45 |
6 | 13 | 2067.60 | 20 | 12.43 | 3460 | 860 | 5.12 / 1244.75 | 5 | 51 |
7 | 13 | 1980.80 | 20 | 12.59 | 3338 | 841 | 5.96 / 1245.59 | 5 | 55 |
8 | 13 | 1668.80 | 20 | 12.89 | 2856 | 736 | 6.69 / 1246.32 | 5 | 66 |
9 | 13 | 1009.76 | 20 | 13.32 | 1904 | 507 | 7.20 / 1246.83 | 5 | 89 |
10 | 13 | 263.28 | 20 | 13.87 | 779 | 216 | 7.42 / 1247.05 | 5 | 93 |
11 | 13 | 37.00 | 20 | 14.18 | 396 | 112 | 7.53 / 1247.16 | 5 | 85 |
12 | 8 | -0.36 | 223 | 14.28 | 327 | 1041 | 8.57 / 1248.20 | 5 | 130 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 62 | 14.06 | 467 | 407 | 0.41 / 1236.79 | 5 | 17 |
2 | 7 | 1096.88 | 80 | 10.01 | 1988 | 1592 | 2.00 / 1238.38 | 5 | 49 |
3 | 13 | 171.92 | 20 | 13.87 | 624 | 173 | 2.17 / 1238.55 | 5 | 92 |
4 | 8 | -0.28 | 239 | 14.11 | 320 | 1079 | 3.25 / 1239.63 | 5 | 132 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 62 | 14.04 | 464 | 404 | 0.40 / 1233.57 | 5 | 19 |
2 | 7 | 1087.52 | 81 | 9.88 | 1976 | 1581 | 1.99 / 1235.15 | 19 | 49 |
3 | 13 | 93.24 | 20 | 13.99 | 495 | 139 | 2.12 / 1235.29 | 5 | 85 |
4 | 13 | 6.24 | 20 | 14.12 | 339 | 96 | 2.22 / 1235.38 | 5 | 81 |
5 | 8 | 0.00 | 218 | 14.12 | 324 | 997 | 3.22 / 1236.38 | 5 | 130 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 63 | 14.18 | 466 | 416 | 0.42 / 1230.31 | 5 | 17 |
2 | 7 | 1080.52 | 81 | 10.00 | 1965 | 1592 | 2.01 / 1231.90 | 17 | 49 |
3 | 13 | 143.44 | 20 | 13.92 | 576 | 160 | 2.17 / 1232.06 | 5 | 91 |
4 | 8 | -0.36 | 242 | 14.13 | 322 | 1101 | 3.27 / 1233.16 | 5 | 143 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 63 | 14.01 | 467 | 412 | 0.41 / 1221.84 | 5 | 18 |
2 | 3 | 965.52 | -1 | 14.01 | 467 | 0 | 0.00 / 1221.84 | 5 | 18 |
3 | 7 | 2007.28 | 80 | 8.26 | 3249 | 2147 | 2.56 / 1223.99 | 18 | 9 |
4 | 13 | 2089.96 | 20 | 12.12 | 3477 | 843 | 3.40 / 1224.83 | 5 | 42 |
5 | 13 | 2115.04 | 20 | 12.33 | 3531 | 871 | 4.27 / 1225.70 | 5 | 46 |
6 | 13 | 2057.68 | 20 | 12.44 | 3456 | 860 | 5.13 / 1226.56 | 5 | 51 |
7 | 13 | 1972.56 | 20 | 12.59 | 3317 | 835 | 5.97 / 1227.39 | 5 | 55 |
8 | 13 | 1463.32 | 20 | 13.01 | 2561 | 666 | 6.63 / 1228.06 | 5 | 72 |
9 | 13 | 926.84 | 20 | 13.38 | 1776 | 475 | 7.11 / 1228.54 | 5 | 89 |
10 | 13 | 273.52 | 20 | 13.88 | 787 | 218 | 7.33 / 1228.76 | 5 | 94 |
11 | 13 | 32.64 | 20 | 14.14 | 393 | 111 | 7.44 / 1228.87 | 5 | 89 |
12 | 8 | -0.24 | 220 | 14.26 | 327 | 1026 | 8.46 / 1229.89 | 5 | 130 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 62 | 14.04 | 462 | 402 | 0.40 / 1218.64 | 5 | 20 |
2 | 7 | 1074.52 | 80 | 10.03 | 1949 | 1564 | 1.97 / 1220.20 | 20 | 52 |
3 | 13 | 86.32 | 20 | 13.96 | 472 | 132 | 2.10 / 1220.34 | 5 | 85 |
4 | 13 | 4.40 | 20 | 14.16 | 329 | 93 | 2.19 / 1220.43 | 5 | 81 |
5 | 8 | -0.24 | 221 | 14.11 | 320 | 998 | 3.19 / 1221.43 | 5 | 141 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 62 | 14.08 | 472 | 412 | 0.41 / 1215.40 | 5 | 19 |
2 | 7 | 1092.36 | 80 | 9.97 | 1984 | 1582 | 1.99 / 1216.98 | 19 | 50 |
3 | 13 | 170.12 | 20 | 13.85 | 617 | 171 | 2.17 / 1217.15 | 5 | 92 |
4 | 13 | 3.28 | 20 | 14.17 | 325 | 92 | 2.26 / 1217.24 | 5 | 75 |
5 | 8 | 0.04 | 220 | 14.14 | 320 | 995 | 3.25 / 1218.24 | 5 | 130 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 63 | 14.17 | 475 | 424 | 0.42 / 1212.15 | 5 | 16 |
2 | 7 | 1095.08 | 81 | 10.00 | 1985 | 1608 | 2.03 / 1213.76 | 16 | 49 |
3 | 13 | 93.52 | 20 | 14.00 | 490 | 137 | 2.17 / 1213.90 | 5 | 87 |
4 | 8 | -0.12 | 237 | 14.14 | 324 | 1086 | 3.25 / 1214.99 | 5 | 131 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 63 | 13.96 | 455 | 400 | 0.40 / 1203.89 | 5 | 17 |
2 | 7 | 2006.44 | 81 | 8.37 | 3234 | 2193 | 2.59 / 1206.08 | 17 | 10 |
3 | 13 | 2079.48 | 20 | 12.21 | 3455 | 844 | 3.44 / 1206.93 | 5 | 43 |
4 | 13 | 2083.20 | 20 | 12.37 | 3464 | 857 | 4.29 / 1207.78 | 5 | 47 |
5 | 13 | 2014.60 | 20 | 12.49 | 3384 | 845 | 5.14 / 1208.63 | 5 | 54 |
6 | 13 | 1919.56 | 20 | 12.62 | 3257 | 822 | 5.96 / 1209.45 | 5 | 57 |
7 | 13 | 1376.00 | 20 | 13.06 | 2441 | 638 | 6.60 / 1210.09 | 5 | 75 |
8 | 13 | 744.92 | 20 | 13.49 | 1496 | 404 | 7.00 / 1210.49 | 5 | 91 |
9 | 13 | 103.00 | 20 | 14.07 | 506 | 142 | 7.14 / 1210.63 | 5 | 91 |
10 | 8 | -0.24 | 239 | 14.28 | 321 | 1096 | 8.24 / 1211.73 | 5 | 144 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 62 | 14.05 | 452 | 394 | 0.39 / 1200.65 | 5 | 18 |
2 | 7 | 1113.56 | 81 | 10.13 | 1998 | 1639 | 2.03 / 1202.29 | 5 | 51 |
3 | 13 | 178.36 | 20 | 13.85 | 628 | 174 | 2.21 / 1202.46 | 5 | 91 |
4 | 13 | 2.96 | 20 | 14.19 | 308 | 87 | 2.29 / 1202.55 | 5 | 79 |
5 | 8 | -0.16 | 218 | 14.15 | 305 | 941 | 3.24 / 1203.49 | 5 | 134 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 62 | 14.07 | 449 | 392 | 0.39 / 1197.46 | 5 | 17 |
2 | 7 | 1097.40 | 80 | 10.08 | 1985 | 1601 | 1.99 / 1199.07 | 17 | 51 |
3 | 13 | 85.60 | 20 | 13.99 | 475 | 133 | 2.13 / 1199.20 | 5 | 84 |
4 | 8 | -0.12 | 239 | 14.13 | 313 | 1057 | 3.18 / 1200.26 | 5 | 131 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 63 | 14.18 | 449 | 401 | 0.40 / 1194.30 | 5 | 15 |
2 | 7 | 1080.92 | 81 | 10.14 | 1960 | 1610 | 2.01 / 1195.91 | 15 | 51 |
3 | 13 | 73.20 | 20 | 14.02 | 446 | 125 | 2.14 / 1196.03 | 5 | 88 |
4 | 13 | 1.72 | 20 | 14.19 | 315 | 89 | 2.23 / 1196.12 | 5 | 77 |
5 | 8 | -0.28 | 219 | 14.16 | 307 | 952 | 3.18 / 1197.07 | 5 | 136 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 63 | 14.00 | 469 | 414 | 0.41 / 1186.03 | 5 | 15 |
2 | 7 | 2030.56 | 80 | 8.48 | 3302 | 2240 | 2.65 / 1188.27 | 15 | 10 |
3 | 13 | 2101.44 | 20 | 12.17 | 3504 | 853 | 3.51 / 1189.12 | 5 | 43 |
4 | 13 | 2084.88 | 20 | 12.33 | 3482 | 859 | 4.37 / 1189.98 | 5 | 47 |
5 | 13 | 2015.12 | 20 | 12.46 | 3381 | 843 | 5.21 / 1190.82 | 5 | 54 |
6 | 13 | 1918.32 | 20 | 12.59 | 3232 | 814 | 6.02 / 1191.64 | 5 | 58 |
7 | 13 | 1487.64 | 20 | 12.96 | 2591 | 672 | 6.69 / 1192.31 | 5 | 72 |
8 | 13 | 732.40 | 20 | 13.47 | 1460 | 393 | 7.09 / 1192.70 | 5 | 92 |
9 | 13 | 97.04 | 20 | 14.07 | 491 | 138 | 7.22 / 1192.84 | 5 | 94 |
10 | 13 | 7.80 | 20 | 14.22 | 328 | 93 | 7.32 / 1192.93 | 5 | 88 |
11 | 8 | -0.40 | 216 | 14.26 | 312 | 961 | 8.28 / 1193.90 | 5 | 132 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 61 | 14.03 | 443 | 379 | 0.38 / 1182.69 | 5 | 15 |
2 | 3 | 1040.40 | 1 | 11.83 | 1949 | 23 | 0.40 / 1182.72 | 5 | 8 |
3 | 7 | 1131.56 | 81 | 10.11 | 2037 | 1668 | 2.07 / 1184.39 | 8 | 53 |
4 | 13 | 104.08 | 20 | 13.97 | 501 | 140 | 2.21 / 1184.53 | 5 | 91 |
5 | 13 | 26.24 | 20 | 14.11 | 363 | 102 | 2.31 / 1184.63 | 5 | 84 |
6 | 8 | -0.12 | 223 | 14.12 | 314 | 989 | 3.30 / 1185.62 | 5 | 133 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 63 | 14.07 | 454 | 402 | 0.40 / 1179.52 | 5 | 16 |
2 | 3 | 961.04 | -1 | 14.07 | 454 | 0 | 0.00 / 1179.52 | 5 | 16 |
3 | 7 | 1107.80 | 80 | 10.17 | 1995 | 1623 | 2.03 / 1181.14 | 16 | 53 |
4 | 13 | 100.32 | 20 | 13.98 | 470 | 131 | 2.16 / 1181.27 | 5 | 92 |
5 | 13 | 10.24 | 20 | 14.15 | 327 | 93 | 2.25 / 1181.37 | 5 | 84 |
6 | 8 | -0.20 | 220 | 14.13 | 305 | 948 | 3.20 / 1182.32 | 5 | 135 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 63 | 14.07 | 461 | 409 | 0.41 / 1176.35 | 5 | 16 |
2 | 7 | 1063.12 | 80 | 10.02 | 1934 | 1550 | 1.96 / 1177.90 | 16 | 53 |
3 | 13 | 133.24 | 20 | 13.92 | 556 | 155 | 2.11 / 1178.05 | 5 | 95 |
4 | 8 | -0.44 | 242 | 14.12 | 312 | 1066 | 3.18 / 1179.12 | 5 | 141 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 63 | 14.01 | 474 | 418 | 0.42 / 1171.03 | 5 | 16 |
2 | 7 | 1147.24 | 80 | 10.11 | 2073 | 1677 | 2.10 / 1172.71 | 16 | 45 |
3 | 13 | 1147.12 | 20 | 12.83 | 2095 | 538 | 2.63 / 1173.24 | 5 | 74 |
4 | 13 | 1146.80 | 20 | 12.92 | 2103 | 543 | 3.18 / 1173.79 | 5 | 77 |
5 | 13 | 1071.92 | 20 | 13.01 | 1996 | 519 | 3.70 / 1174.31 | 5 | 82 |
6 | 13 | 765.28 | 20 | 13.34 | 1512 | 403 | 4.10 / 1174.71 | 5 | 91 |
7 | 13 | 112.28 | 20 | 14.03 | 519 | 146 | 4.24 / 1174.86 | 5 | 93 |
8 | 13 | 15.24 | 20 | 14.20 | 345 | 98 | 4.34 / 1174.95 | 5 | 84 |
9 | 13 | 2.92 | 20 | 14.20 | 324 | 92 | 4.43 / 1175.05 | 5 | 79 |
10 | 8 | -0.24 | 199 | 14.21 | 314 | 888 | 5.32 / 1175.93 | 5 | 134 |
11 | 14 | -0.36 | 1 | 14.25 | 309 | 4 | 5.33 / 1175.94 | 37 | 98 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 63 | 14.06 | 453 | 401 | 0.40 / 1167.81 | 5 | 15 |
2 | 7 | 1084.96 | 80 | 10.20 | 1963 | 1602 | 2.00 / 1169.41 | 15 | 54 |
3 | 13 | 80.92 | 20 | 13.99 | 456 | 128 | 2.13 / 1169.54 | 5 | 89 |
4 | 13 | 42.04 | 20 | 14.07 | 387 | 109 | 2.24 / 1169.65 | 5 | 86 |
5 | 8 | -0.16 | 220 | 14.11 | 311 | 965 | 3.20 / 1170.61 | 5 | 144 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 64 | 14.01 | 445 | 399 | 0.40 / 1164.63 | 5 | 16 |
2 | 3 | 910.44 | -1 | 14.01 | 445 | 0 | 0.00 / 1164.63 | 5 | 16 |
3 | 7 | 1070.08 | 80 | 10.24 | 1942 | 1591 | 1.99 / 1166.22 | 16 | 54 |
4 | 13 | 128.32 | 20 | 13.92 | 542 | 151 | 2.14 / 1166.37 | 5 | 94 |
5 | 8 | -0.16 | 239 | 14.13 | 307 | 1037 | 3.18 / 1167.41 | 5 | 140 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 63 | 14.12 | 470 | 418 | 0.42 / 1161.39 | 5 | 13 |
2 | 7 | 1096.16 | 81 | 9.93 | 1993 | 1603 | 2.02 / 1163.00 | 13 | 51 |
3 | 13 | 104.40 | 20 | 13.97 | 508 | 142 | 2.16 / 1163.14 | 5 | 90 |
4 | 13 | 54.56 | 20 | 14.07 | 410 | 115 | 2.28 / 1163.25 | 5 | 87 |
5 | 8 | -0.28 | 220 | 14.15 | 313 | 974 | 3.25 / 1164.23 | 5 | 137 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 63 | 14.03 | 466 | 412 | 0.41 / 1156.09 | 5 | 13 |
2 | 7 | 1134.68 | 81 | 10.07 | 2051 | 1673 | 2.08 / 1157.76 | 13 | 44 |
3 | 13 | 1134.16 | 20 | 12.85 | 2086 | 536 | 2.62 / 1158.29 | 5 | 76 |
4 | 13 | 1134.20 | 20 | 12.95 | 2080 | 539 | 3.16 / 1158.83 | 5 | 77 |
5 | 13 | 1068.00 | 20 | 13.07 | 1980 | 518 | 3.68 / 1159.35 | 5 | 83 |
6 | 13 | 762.68 | 20 | 13.36 | 1518 | 406 | 4.08 / 1159.76 | 5 | 90 |
7 | 13 | 112.32 | 20 | 14.02 | 525 | 147 | 4.23 / 1159.90 | 5 | 91 |
8 | 13 | 14.00 | 20 | 14.20 | 341 | 97 | 4.33 / 1160.00 | 5 | 83 |
9 | 8 | -0.16 | 219 | 14.22 | 313 | 975 | 5.30 / 1160.98 | 5 | 144 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.56 | 63 | 14.09 | 476 | 423 | 0.42 / 1152.70 | 5 | 12 |
2 | 3 | 1040.44 | 1 | 11.83 | 1959 | 23 | 0.45 / 1152.72 | 5 | 10 |
3 | 7 | 1128.48 | 80 | 10.08 | 2049 | 1652 | 2.10 / 1154.38 | 10 | 53 |
4 | 13 | 201.44 | 20 | 13.82 | 685 | 189 | 2.29 / 1154.57 | 5 | 93 |
5 | 13 | 44.16 | 20 | 14.11 | 396 | 112 | 2.40 / 1154.68 | 5 | 85 |
6 | 8 | -0.40 | 223 | 14.14 | 316 | 996 | 3.40 / 1155.67 | 5 | 143 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 63 | 14.04 | 478 | 423 | 0.42 / 1149.37 | 5 | 12 |
2 | 7 | 1110.28 | 80 | 10.14 | 2019 | 1638 | 2.06 / 1151.01 | 5 | 52 |
3 | 13 | 180.84 | 20 | 13.86 | 643 | 178 | 2.24 / 1151.18 | 5 | 93 |
4 | 8 | -0.24 | 242 | 14.14 | 320 | 1095 | 3.33 / 1152.28 | 5 | 137 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 66 | 14.22 | 463 | 435 | 0.43 / 1146.12 | 5 | 11 |
2 | 3 | 900.12 | -2 | 14.22 | 463 | 0 | 0.00 / 1146.12 | 5 | 11 |
3 | 7 | 1097.60 | 81 | 10.15 | 1983 | 1630 | 2.06 / 1147.75 | 11 | 51 |
4 | 13 | 150.96 | 20 | 13.93 | 574 | 160 | 2.22 / 1147.91 | 5 | 92 |
5 | 8 | -0.28 | 239 | 14.19 | 305 | 1034 | 3.26 / 1148.94 | 5 | 135 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 63 | 14.06 | 453 | 401 | 0.40 / 1139.20 | 5 | 10 |
2 | 7 | 1603.52 | 80 | 9.18 | 2708 | 1989 | 2.39 / 1141.19 | 10 | 26 |
3 | 13 | 1603.04 | 20 | 12.54 | 2784 | 698 | 3.09 / 1141.89 | 5 | 62 |
4 | 13 | 1603.32 | 20 | 12.61 | 2804 | 707 | 3.80 / 1142.60 | 5 | 66 |
5 | 13 | 1602.88 | 20 | 12.70 | 2789 | 708 | 4.50 / 1143.30 | 5 | 67 |
6 | 13 | 1511.28 | 20 | 12.82 | 2663 | 683 | 5.19 / 1143.99 | 5 | 74 |
7 | 13 | 838.16 | 20 | 13.37 | 1639 | 438 | 5.62 / 1144.42 | 5 | 90 |
8 | 13 | 168.72 | 20 | 13.97 | 614 | 172 | 5.80 / 1144.60 | 5 | 92 |
9 | 13 | 49.80 | 20 | 14.17 | 402 | 114 | 5.91 / 1144.71 | 5 | 80 |
10 | 8 | -0.20 | 218 | 14.29 | 313 | 975 | 6.89 / 1145.69 | 5 | 133 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 63 | 14.10 | 452 | 402 | 0.40 / 1135.93 | 5 | 11 |
2 | 7 | 1097.88 | 80 | 10.26 | 1988 | 1632 | 2.03 / 1137.56 | 11 | 53 |
3 | 13 | 158.96 | 20 | 13.90 | 599 | 167 | 2.20 / 1137.73 | 5 | 88 |
4 | 13 | 38.24 | 20 | 14.13 | 376 | 106 | 2.31 / 1137.83 | 5 | 77 |
5 | 8 | -0.20 | 220 | 14.17 | 310 | 966 | 3.27 / 1138.80 | 5 | 134 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 63 | 14.13 | 456 | 406 | 0.41 / 1132.70 | 5 | 11 |
2 | 7 | 1106.88 | 80 | 10.15 | 2000 | 1624 | 2.03 / 1134.33 | 5 | 53 |
3 | 13 | 100.16 | 20 | 13.99 | 495 | 139 | 2.17 / 1134.46 | 5 | 84 |
4 | 13 | 53.64 | 20 | 14.12 | 400 | 113 | 2.28 / 1134.58 | 5 | 79 |
5 | 8 | -0.20 | 220 | 14.20 | 304 | 950 | 3.23 / 1135.53 | 5 | 131 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 63 | 14.17 | 483 | 431 | 0.43 / 1129.29 | 5 | 10 |
2 | 10 | 1000.64 | 3 | 12.56 | 1897 | 71 | 0.50 / 1129.36 | 5 | 43 |
3 | 7 | 1123.80 | 80 | 10.18 | 2031 | 1654 | 2.16 / 1131.02 | 5 | 51 |
4 | 13 | 193.84 | 20 | 13.87 | 653 | 181 | 2.34 / 1131.20 | 5 | 90 |
5 | 13 | 47.64 | 20 | 14.14 | 402 | 114 | 2.45 / 1131.31 | 5 | 77 |
6 | 8 | -0.28 | 221 | 14.21 | 313 | 983 | 3.43 / 1132.30 | 5 | 135 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 63 | 14.16 | 457 | 408 | 0.41 / 1123.25 | 5 | 10 |
2 | 7 | 1313.16 | 80 | 9.72 | 2307 | 1794 | 2.20 / 1125.04 | 5 | 38 |
3 | 13 | 1313.00 | 20 | 12.74 | 2352 | 599 | 2.80 / 1125.64 | 5 | 69 |
4 | 13 | 1312.52 | 20 | 12.84 | 2361 | 606 | 3.41 / 1126.25 | 5 | 74 |
5 | 13 | 1312.92 | 20 | 12.90 | 2345 | 605 | 4.01 / 1126.85 | 5 | 76 |
6 | 13 | 1214.40 | 20 | 13.03 | 2189 | 570 | 4.58 / 1127.42 | 5 | 80 |
7 | 13 | 425.12 | 20 | 13.69 | 1016 | 278 | 4.86 / 1127.70 | 5 | 93 |
8 | 13 | 58.72 | 20 | 14.14 | 424 | 120 | 4.98 / 1127.82 | 5 | 80 |
9 | 13 | 31.60 | 20 | 14.21 | 374 | 106 | 5.09 / 1127.93 | 5 | 78 |
10 | 8 | -0.20 | 206 | 14.27 | 318 | 935 | 6.02 / 1128.86 | 5 | 136 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 63 | 14.13 | 461 | 410 | 0.41 / 1119.93 | 5 | 10 |
2 | 7 | 1103.68 | 80 | 10.19 | 2006 | 1635 | 2.05 / 1121.56 | 5 | 54 |
3 | 13 | 174.84 | 20 | 13.89 | 629 | 175 | 2.22 / 1121.74 | 5 | 91 |
4 | 13 | 45.00 | 20 | 14.11 | 392 | 111 | 2.33 / 1121.85 | 5 | 79 |
5 | 8 | -0.32 | 223 | 14.20 | 313 | 991 | 3.32 / 1122.84 | 5 | 143 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 63 | 14.18 | 450 | 402 | 0.40 / 1116.66 | 5 | 10 |
2 | 7 | 1075.16 | 81 | 10.25 | 1957 | 1625 | 2.03 / 1118.28 | 10 | 55 |
3 | 13 | 130.12 | 20 | 13.97 | 552 | 154 | 2.18 / 1118.44 | 5 | 87 |
4 | 13 | 66.16 | 20 | 14.08 | 426 | 120 | 2.30 / 1118.56 | 5 | 81 |
5 | 8 | -0.36 | 218 | 14.20 | 310 | 960 | 3.26 / 1119.52 | 5 | 131 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 62 | 14.21 | 463 | 408 | 0.41 / 1113.35 | 6 | 9 |
2 | 7 | 1107.64 | 81 | 10.23 | 2020 | 1674 | 2.08 / 1115.02 | 5 | 50 |
3 | 13 | 96.32 | 20 | 14.04 | 488 | 137 | 2.22 / 1115.16 | 5 | 81 |
4 | 13 | 50.80 | 20 | 14.13 | 409 | 116 | 2.33 / 1115.27 | 5 | 77 |
5 | 8 | -0.28 | 220 | 14.22 | 314 | 982 | 3.32 / 1116.26 | 5 | 139 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 63 | 14.15 | 446 | 398 | 0.40 / 1105.13 | 5 | 9 |
2 | 7 | 2006.96 | 81 | 8.88 | 3255 | 2341 | 2.74 / 1107.47 | 5 | 13 |
3 | 13 | 2073.12 | 20 | 12.21 | 3472 | 848 | 3.59 / 1108.32 | 5 | 45 |
4 | 13 | 2042.76 | 20 | 12.39 | 3422 | 848 | 4.43 / 1109.16 | 5 | 50 |
5 | 13 | 1968.12 | 20 | 12.52 | 3312 | 829 | 5.26 / 1109.99 | 5 | 55 |
6 | 13 | 1869.76 | 20 | 12.65 | 3163 | 800 | 6.06 / 1110.79 | 5 | 60 |
7 | 13 | 1227.84 | 20 | 13.11 | 2226 | 584 | 6.65 / 1111.38 | 5 | 81 |
8 | 13 | 583.24 | 20 | 13.58 | 1261 | 342 | 6.99 / 1111.72 | 5 | 94 |
9 | 13 | 72.08 | 20 | 14.14 | 463 | 131 | 7.12 / 1111.85 | 5 | 86 |
10 | 13 | 37.68 | 20 | 14.22 | 399 | 113 | 7.23 / 1111.96 | 5 | 83 |
11 | 8 | -0.44 | 211 | 14.28 | 324 | 976 | 8.21 / 1112.94 | 5 | 131 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 63 | 14.10 | 456 | 405 | 0.41 / 1101.92 | 5 | 10 |
2 | 7 | 1105.12 | 81 | 10.22 | 1996 | 1652 | 2.06 / 1103.57 | 5 | 53 |
3 | 13 | 88.64 | 20 | 14.01 | 462 | 129 | 2.19 / 1103.70 | 5 | 86 |
4 | 13 | 46.68 | 20 | 14.09 | 383 | 108 | 2.29 / 1103.81 | 5 | 82 |
5 | 8 | -0.28 | 216 | 14.19 | 300 | 920 | 3.21 / 1104.73 | 5 | 134 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 63 | 14.15 | 460 | 410 | 0.41 / 1098.66 | 5 | 10 |
2 | 7 | 1081.72 | 81 | 10.36 | 1968 | 1651 | 2.06 / 1100.31 | 10 | 54 |
3 | 13 | 63.00 | 20 | 14.03 | 443 | 124 | 2.19 / 1100.43 | 5 | 87 |
4 | 13 | 34.16 | 20 | 14.09 | 387 | 109 | 2.29 / 1100.54 | 5 | 86 |
5 | 8 | -0.40 | 216 | 14.14 | 319 | 974 | 3.27 / 1101.52 | 5 | 136 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 62 | 14.20 | 459 | 404 | 0.40 / 1095.34 | 5 | 10 |
2 | 7 | 1091.16 | 81 | 10.30 | 1982 | 1654 | 2.06 / 1096.99 | 10 | 52 |
3 | 13 | 71.20 | 20 | 14.02 | 463 | 130 | 2.19 / 1097.12 | 5 | 91 |
4 | 13 | 36.48 | 20 | 14.09 | 400 | 113 | 2.30 / 1097.23 | 5 | 91 |
5 | 8 | -0.52 | 220 | 14.13 | 326 | 1013 | 3.31 / 1098.25 | 5 | 139 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 63 | 14.11 | 470 | 418 | 0.42 / 1087.24 | 5 | 10 |
2 | 7 | 2006.36 | 81 | 8.92 | 3273 | 2365 | 2.78 / 1089.61 | 10 | 13 |
3 | 13 | 2068.32 | 20 | 12.24 | 3447 | 844 | 3.63 / 1090.45 | 5 | 46 |
4 | 13 | 2033.92 | 20 | 12.45 | 3417 | 851 | 4.48 / 1091.30 | 5 | 50 |
5 | 13 | 1955.56 | 20 | 12.54 | 3294 | 826 | 5.30 / 1092.13 | 5 | 55 |
6 | 13 | 1658.12 | 20 | 12.81 | 2852 | 731 | 6.03 / 1092.86 | 5 | 67 |
7 | 13 | 1136.80 | 20 | 13.18 | 2089 | 551 | 6.58 / 1093.41 | 5 | 85 |
8 | 13 | 504.40 | 20 | 13.61 | 1149 | 313 | 6.90 / 1093.72 | 5 | 96 |
9 | 13 | 45.24 | 20 | 14.16 | 424 | 120 | 7.02 / 1093.84 | 5 | 89 |
10 | 13 | 24.76 | 20 | 14.21 | 378 | 107 | 7.13 / 1093.95 | 5 | 89 |
11 | 8 | -0.60 | 212 | 14.25 | 325 | 982 | 8.11 / 1094.93 | 5 | 129 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 63 | 14.13 | 454 | 404 | 0.40 / 1083.95 | 5 | 10 |
2 | 7 | 1076.48 | 81 | 10.40 | 1960 | 1651 | 2.06 / 1085.60 | 10 | 55 |
3 | 13 | 62.52 | 20 | 14.04 | 440 | 124 | 2.18 / 1085.73 | 5 | 89 |
4 | 13 | 34.04 | 20 | 14.09 | 389 | 110 | 2.29 / 1085.84 | 5 | 86 |
5 | 8 | -0.32 | 218 | 14.13 | 321 | 989 | 3.28 / 1086.83 | 5 | 137 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 63 | 14.11 | 463 | 412 | 0.41 / 1080.69 | 5 | 10 |
2 | 7 | 1072.40 | 80 | 10.37 | 1963 | 1629 | 2.04 / 1082.32 | 10 | 56 |
3 | 13 | 64.20 | 20 | 14.03 | 448 | 126 | 2.17 / 1082.44 | 5 | 90 |
4 | 13 | 19.20 | 20 | 14.11 | 368 | 104 | 2.27 / 1082.55 | 5 | 88 |
5 | 8 | -0.40 | 218 | 14.13 | 325 | 1001 | 3.27 / 1083.55 | 5 | 145 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 62 | 14.30 | 446 | 395 | 0.40 / 1077.43 | 6 | 8 |
2 | 7 | 1087.88 | 80 | 10.36 | 1986 | 1646 | 2.04 / 1079.07 | 8 | 52 |
3 | 13 | 75.24 | 20 | 14.06 | 452 | 127 | 2.17 / 1079.20 | 5 | 90 |
4 | 13 | 22.72 | 20 | 14.14 | 366 | 104 | 2.27 / 1079.30 | 5 | 86 |
5 | 8 | -0.56 | 216 | 14.16 | 319 | 976 | 3.25 / 1080.28 | 5 | 130 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 63 | 14.15 | 454 | 405 | 0.40 / 1069.57 | 5 | 9 |
2 | 7 | 1967.44 | 80 | 9.10 | 3222 | 2346 | 2.75 / 1071.92 | 5 | 17 |
3 | 13 | 1966.60 | 20 | 12.35 | 3306 | 817 | 3.57 / 1072.74 | 5 | 52 |
4 | 13 | 1966.12 | 20 | 12.46 | 3315 | 826 | 4.39 / 1073.56 | 5 | 54 |
5 | 13 | 1885.84 | 20 | 12.57 | 3182 | 800 | 5.19 / 1074.36 | 5 | 58 |
6 | 13 | 1578.80 | 20 | 12.87 | 2715 | 699 | 5.89 / 1075.06 | 5 | 68 |
7 | 13 | 1058.48 | 20 | 13.22 | 1974 | 522 | 6.41 / 1075.58 | 5 | 86 |
8 | 13 | 418.56 | 20 | 13.71 | 1009 | 277 | 6.69 / 1075.86 | 5 | 95 |
9 | 13 | 46.88 | 20 | 14.17 | 414 | 117 | 6.81 / 1075.98 | 5 | 91 |
10 | 13 | 27.32 | 20 | 14.21 | 372 | 106 | 6.91 / 1076.08 | 5 | 91 |
11 | 8 | -0.48 | 209 | 14.26 | 318 | 948 | 7.86 / 1077.03 | 5 | 136 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 63 | 14.16 | 441 | 393 | 0.39 / 1066.30 | 5 | 8 |
2 | 7 | 1092.40 | 80 | 10.38 | 1990 | 1652 | 2.05 / 1067.95 | 8 | 56 |
3 | 13 | 75.52 | 20 | 14.02 | 459 | 129 | 2.17 / 1068.08 | 5 | 90 |
4 | 13 | 41.20 | 20 | 14.06 | 400 | 112 | 2.29 / 1068.20 | 5 | 88 |
5 | 8 | -0.60 | 218 | 14.13 | 316 | 973 | 3.26 / 1069.17 | 5 | 133 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 63 | 14.15 | 465 | 415 | 0.41 / 1063.04 | 6 | 8 |
2 | 7 | 1094.28 | 80 | 10.42 | 1989 | 1658 | 2.07 / 1064.70 | 5 | 55 |
3 | 13 | 79.36 | 20 | 14.01 | 465 | 130 | 2.20 / 1064.83 | 5 | 90 |
4 | 13 | 42.96 | 20 | 14.11 | 399 | 113 | 2.32 / 1064.94 | 5 | 87 |
5 | 8 | -0.52 | 218 | 14.18 | 313 | 968 | 3.28 / 1065.91 | 5 | 134 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 62 | 14.29 | 450 | 399 | 0.40 / 1059.74 | 6 | 7 |
2 | 7 | 1108.80 | 80 | 10.40 | 2022 | 1682 | 2.08 / 1061.42 | 5 | 53 |
3 | 13 | 86.72 | 20 | 14.05 | 468 | 132 | 2.21 / 1061.55 | 5 | 87 |
4 | 13 | 25.40 | 20 | 14.17 | 364 | 103 | 2.32 / 1061.66 | 5 | 82 |
5 | 8 | -0.52 | 218 | 14.20 | 313 | 969 | 3.28 / 1062.63 | 5 | 133 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 62 | 14.16 | 458 | 402 | 0.40 / 1051.67 | 6 | 8 |
2 | 3 | 1027.56 | 1 | 11.86 | 1941 | 23 | 0.43 / 1051.69 | 5 | 5 |
3 | 7 | 2007.44 | 80 | 9.07 | 3267 | 2371 | 2.80 / 1054.06 | 5 | 15 |
4 | 13 | 2071.68 | 20 | 12.29 | 3462 | 851 | 3.65 / 1054.91 | 5 | 46 |
5 | 13 | 2037.80 | 20 | 12.44 | 3411 | 849 | 4.50 / 1055.76 | 5 | 51 |
6 | 13 | 1958.44 | 20 | 12.58 | 3293 | 829 | 5.32 / 1056.59 | 5 | 56 |
7 | 13 | 1658.08 | 20 | 12.81 | 2838 | 727 | 6.05 / 1057.32 | 5 | 67 |
8 | 13 | 1120.56 | 20 | 13.19 | 2055 | 542 | 6.59 / 1057.86 | 5 | 84 |
9 | 13 | 483.04 | 20 | 13.66 | 1095 | 299 | 6.89 / 1058.16 | 5 | 95 |
10 | 13 | 69.76 | 20 | 14.16 | 450 | 127 | 7.02 / 1058.29 | 5 | 88 |
11 | 13 | 18.04 | 20 | 14.28 | 354 | 101 | 7.12 / 1058.39 | 5 | 85 |
12 | 8 | -0.40 | 211 | 14.29 | 316 | 953 | 8.07 / 1059.34 | 5 | 135 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 62 | 14.15 | 452 | 397 | 0.40 / 1048.39 | 5 | 9 |
2 | 7 | 1107.08 | 80 | 10.40 | 2006 | 1669 | 2.07 / 1050.06 | 5 | 55 |
3 | 13 | 85.32 | 20 | 14.02 | 472 | 132 | 2.20 / 1050.19 | 5 | 87 |
4 | 13 | 25.68 | 20 | 14.14 | 366 | 104 | 2.30 / 1050.30 | 5 | 81 |
5 | 8 | -0.44 | 218 | 14.17 | 314 | 970 | 3.27 / 1051.27 | 5 | 138 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 62 | 14.19 | 449 | 395 | 0.40 / 1045.07 | 5 | 9 |
2 | 7 | 1099.64 | 81 | 10.43 | 2007 | 1696 | 2.09 / 1046.76 | 5 | 56 |
3 | 13 | 77.32 | 20 | 14.03 | 471 | 132 | 2.22 / 1046.90 | 5 | 87 |
4 | 13 | 39.56 | 20 | 14.11 | 399 | 113 | 2.34 / 1047.01 | 5 | 84 |
5 | 8 | -0.44 | 218 | 14.16 | 320 | 988 | 3.32 / 1048.00 | 5 | 141 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 62 | 14.27 | 451 | 399 | 0.40 / 1041.81 | 6 | 8 |
2 | 7 | 1095.64 | 81 | 10.47 | 1984 | 1683 | 2.08 / 1043.49 | 5 | 55 |
3 | 13 | 72.76 | 20 | 14.08 | 448 | 126 | 2.21 / 1043.62 | 5 | 87 |
4 | 13 | 22.08 | 20 | 14.19 | 357 | 101 | 2.31 / 1043.72 | 5 | 82 |
5 | 8 | -0.60 | 216 | 14.20 | 311 | 954 | 3.26 / 1044.67 | 5 | 138 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 62 | 14.17 | 443 | 389 | 0.39 / 1033.75 | 5 | 8 |
2 | 7 | 2007.96 | 80 | 9.16 | 3263 | 2391 | 2.78 / 1036.14 | 5 | 15 |
3 | 13 | 2071.88 | 20 | 12.31 | 3471 | 855 | 3.63 / 1037.00 | 5 | 46 |
4 | 13 | 2035.44 | 20 | 12.45 | 3412 | 850 | 4.48 / 1037.85 | 5 | 51 |
5 | 13 | 1958.24 | 20 | 12.58 | 3289 | 828 | 5.31 / 1038.67 | 5 | 56 |
6 | 13 | 1659.96 | 20 | 12.84 | 2827 | 726 | 6.04 / 1039.40 | 5 | 66 |
7 | 13 | 1128.96 | 20 | 13.17 | 2065 | 544 | 6.58 / 1039.94 | 5 | 84 |
8 | 13 | 481.04 | 20 | 13.65 | 1105 | 302 | 6.88 / 1040.24 | 5 | 97 |
9 | 13 | 63.28 | 20 | 14.14 | 436 | 123 | 7.01 / 1040.37 | 5 | 91 |
10 | 13 | 17.16 | 20 | 14.24 | 355 | 101 | 7.11 / 1040.47 | 5 | 87 |
11 | 8 | -0.56 | 209 | 14.25 | 316 | 941 | 8.05 / 1041.41 | 5 | 133 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 62 | 14.17 | 440 | 387 | 0.39 / 1030.48 | 5 | 9 |
2 | 7 | 1098.04 | 81 | 10.51 | 1984 | 1689 | 2.08 / 1032.17 | 5 | 56 |
3 | 13 | 67.36 | 20 | 14.05 | 438 | 123 | 2.20 / 1032.29 | 5 | 90 |
4 | 13 | 21.40 | 20 | 14.14 | 358 | 101 | 2.30 / 1032.39 | 5 | 85 |
5 | 13 | 8.44 | 20 | 14.11 | 330 | 93 | 2.39 / 1032.49 | 5 | 86 |
6 | 8 | -0.44 | 197 | 14.16 | 309 | 862 | 3.25 / 1033.35 | 5 | 137 |
7 | 14 | -0.48 | 3 | 14.20 | 306 | 13 | 3.27 / 1033.36 | 31 | 103 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 62 | 14.15 | 446 | 391 | 0.39 / 1027.23 | 5 | 8 |
2 | 7 | 1095.96 | 80 | 10.53 | 1991 | 1677 | 2.07 / 1028.91 | 5 | 56 |
3 | 13 | 70.28 | 20 | 14.03 | 449 | 126 | 2.19 / 1029.03 | 5 | 91 |
4 | 13 | 21.52 | 20 | 14.14 | 366 | 104 | 2.30 / 1029.14 | 5 | 87 |
5 | 8 | -0.28 | 216 | 14.16 | 312 | 954 | 3.25 / 1030.09 | 5 | 133 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 61 | 14.26 | 458 | 398 | 0.40 / 1023.92 | 5 | 7 |
2 | 7 | 1104.00 | 80 | 10.48 | 2000 | 1677 | 2.08 / 1025.60 | 5 | 53 |
3 | 13 | 75.16 | 20 | 14.04 | 468 | 131 | 2.21 / 1025.73 | 5 | 92 |
4 | 13 | 20.76 | 20 | 14.18 | 369 | 105 | 2.31 / 1025.83 | 5 | 88 |
5 | 13 | 7.56 | 20 | 14.17 | 343 | 97 | 2.41 / 1025.93 | 5 | 88 |
6 | 8 | -0.68 | 197 | 14.16 | 322 | 898 | 3.31 / 1026.83 | 5 | 133 |
7 | 14 | -0.72 | 3 | 14.22 | 317 | 14 | 3.32 / 1026.84 | 23 | 94 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 62 | 14.10 | 454 | 397 | 0.40 / 1015.71 | 5 | 9 |
2 | 7 | 2008.68 | 80 | 9.24 | 3283 | 2427 | 2.82 / 1018.14 | 9 | 18 |
3 | 13 | 2067.64 | 20 | 12.30 | 3440 | 846 | 3.67 / 1018.99 | 5 | 47 |
4 | 13 | 2027.08 | 20 | 12.42 | 3406 | 846 | 4.52 / 1019.83 | 5 | 51 |
5 | 13 | 1948.24 | 20 | 12.56 | 3273 | 822 | 5.34 / 1020.65 | 5 | 56 |
6 | 13 | 1743.96 | 20 | 12.76 | 2983 | 761 | 6.10 / 1021.42 | 5 | 65 |
7 | 13 | 1195.04 | 20 | 13.13 | 2167 | 569 | 6.67 / 1021.99 | 5 | 83 |
8 | 13 | 532.92 | 20 | 13.62 | 1159 | 316 | 6.98 / 1022.30 | 5 | 92 |
9 | 13 | 43.12 | 20 | 14.16 | 416 | 118 | 7.10 / 1022.42 | 5 | 93 |
10 | 13 | 22.04 | 20 | 14.20 | 382 | 108 | 7.21 / 1022.53 | 5 | 93 |
11 | 8 | -0.48 | 211 | 14.22 | 331 | 993 | 8.20 / 1023.52 | 5 | 137 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 62 | 14.15 | 441 | 387 | 0.39 / 1012.44 | 5 | 9 |
2 | 7 | 1087.00 | 80 | 10.53 | 1974 | 1663 | 2.05 / 1014.10 | 9 | 57 |
3 | 13 | 67.20 | 20 | 14.01 | 450 | 126 | 2.18 / 1014.23 | 5 | 92 |
4 | 13 | 17.84 | 20 | 14.11 | 365 | 103 | 2.28 / 1014.33 | 5 | 88 |
5 | 8 | -0.44 | 216 | 14.13 | 322 | 983 | 3.26 / 1015.32 | 5 | 134 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 62 | 14.18 | 448 | 394 | 0.39 / 1009.19 | 5 | 9 |
2 | 7 | 1084.36 | 81 | 10.60 | 1968 | 1690 | 2.08 / 1010.88 | 9 | 58 |
3 | 13 | 56.84 | 20 | 14.05 | 425 | 119 | 2.20 / 1011.00 | 5 | 92 |
4 | 13 | 15.88 | 20 | 14.14 | 350 | 99 | 2.30 / 1011.10 | 5 | 89 |
5 | 8 | -0.52 | 216 | 14.13 | 313 | 955 | 3.26 / 1012.05 | 5 | 147 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 61 | 14.31 | 432 | 377 | 0.38 / 1005.96 | 6 | 8 |
2 | 7 | 1079.36 | 81 | 10.59 | 1961 | 1682 | 2.06 / 1007.64 | 8 | 55 |
3 | 13 | 54.96 | 20 | 14.06 | 413 | 116 | 2.18 / 1007.76 | 5 | 91 |
4 | 13 | 16.40 | 20 | 14.19 | 345 | 98 | 2.27 / 1007.86 | 5 | 89 |
5 | 8 | -0.28 | 213 | 14.14 | 312 | 940 | 3.21 / 1008.80 | 5 | 133 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 62 | 14.16 | 449 | 394 | 0.39 / 997.92 | 5 | 9 |
2 | 7 | 2030.60 | 80 | 9.28 | 3312 | 2459 | 2.85 / 1000.38 | 9 | 17 |
3 | 13 | 2086.16 | 20 | 12.30 | 3470 | 854 | 3.71 / 1001.23 | 5 | 46 |
4 | 13 | 2042.00 | 20 | 12.44 | 3409 | 848 | 4.55 / 1002.08 | 5 | 51 |
5 | 13 | 1958.00 | 20 | 12.55 | 3284 | 824 | 5.38 / 1002.90 | 5 | 55 |
6 | 13 | 1652.00 | 20 | 12.84 | 2808 | 721 | 6.10 / 1003.62 | 5 | 65 |
7 | 13 | 1112.16 | 20 | 13.18 | 2042 | 538 | 6.64 / 1004.16 | 5 | 85 |
8 | 13 | 465.64 | 20 | 13.67 | 1073 | 293 | 6.93 / 1004.46 | 5 | 96 |
9 | 13 | 31.92 | 20 | 14.19 | 383 | 109 | 7.04 / 1004.57 | 5 | 91 |
10 | 13 | 17.16 | 20 | 14.23 | 351 | 100 | 7.14 / 1004.67 | 5 | 92 |
11 | 8 | -0.36 | 207 | 14.24 | 312 | 920 | 8.06 / 1005.58 | 5 | 133 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 62 | 14.08 | 446 | 389 | 0.39 / 994.71 | 5 | 10 |
2 | 7 | 1079.68 | 80 | 10.54 | 1961 | 1654 | 2.04 / 996.36 | 10 | 57 |
3 | 13 | 66.60 | 20 | 14.06 | 434 | 122 | 2.16 / 996.48 | 5 | 91 |
4 | 13 | 18.12 | 20 | 14.14 | 358 | 101 | 2.27 / 996.58 | 5 | 89 |
5 | 8 | -0.36 | 213 | 14.15 | 312 | 940 | 3.21 / 997.52 | 5 | 133 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 62 | 14.18 | 447 | 393 | 0.39 / 991.42 | 5 | 10 |
2 | 7 | 1080.88 | 81 | 10.61 | 1981 | 1702 | 2.10 / 993.12 | 10 | 58 |
3 | 13 | 56.52 | 20 | 14.07 | 434 | 122 | 2.22 / 993.25 | 5 | 92 |
4 | 13 | 16.72 | 20 | 14.17 | 358 | 101 | 2.32 / 993.35 | 5 | 88 |
5 | 8 | 0.20 | 213 | 14.12 | 323 | 971 | 3.29 / 994.32 | 5 | 133 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 61 | 14.26 | 440 | 383 | 0.38 / 988.15 | 5 | 8 |
2 | 7 | 1092.60 | 80 | 10.55 | 1991 | 1680 | 2.06 / 989.83 | 5 | 55 |
3 | 13 | 68.08 | 20 | 14.08 | 445 | 125 | 2.19 / 989.95 | 5 | 92 |
4 | 13 | 19.28 | 20 | 14.16 | 360 | 102 | 2.29 / 990.06 | 5 | 89 |
5 | 8 | -0.48 | 216 | 14.16 | 318 | 973 | 3.26 / 991.03 | 5 | 129 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 62 | 14.16 | 457 | 401 | 0.40 / 980.08 | 5 | 9 |
2 | 7 | 2008.52 | 81 | 9.41 | 3276 | 2497 | 2.90 / 982.58 | 5 | 18 |
3 | 13 | 2063.40 | 20 | 12.34 | 3443 | 850 | 3.75 / 983.43 | 5 | 47 |
4 | 13 | 2016.60 | 20 | 12.48 | 3377 | 843 | 4.59 / 984.27 | 5 | 53 |
5 | 13 | 1933.52 | 20 | 12.60 | 3273 | 825 | 5.42 / 985.10 | 5 | 57 |
6 | 13 | 1623.56 | 20 | 12.87 | 2780 | 716 | 6.13 / 985.81 | 5 | 65 |
7 | 13 | 1076.80 | 20 | 13.21 | 1980 | 523 | 6.65 / 986.34 | 5 | 84 |
8 | 13 | 423.12 | 20 | 13.70 | 1003 | 275 | 6.93 / 986.61 | 5 | 97 |
9 | 13 | 42.36 | 20 | 14.18 | 402 | 114 | 7.04 / 986.73 | 5 | 92 |
10 | 13 | 21.44 | 20 | 14.22 | 364 | 104 | 7.15 / 986.83 | 5 | 93 |
11 | 8 | -0.40 | 206 | 14.23 | 319 | 935 | 8.08 / 987.76 | 5 | 138 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 62 | 14.11 | 455 | 398 | 0.40 / 976.77 | 5 | 10 |
2 | 7 | 1086.12 | 81 | 10.59 | 1985 | 1703 | 2.10 / 978.48 | 10 | 57 |
3 | 13 | 63.48 | 20 | 14.06 | 448 | 126 | 2.23 / 978.60 | 5 | 88 |
4 | 13 | 18.16 | 20 | 14.15 | 361 | 102 | 2.33 / 978.70 | 5 | 84 |
5 | 8 | -0.48 | 216 | 14.16 | 320 | 979 | 3.31 / 979.68 | 5 | 142 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 62 | 14.17 | 449 | 394 | 0.39 / 973.46 | 5 | 10 |
2 | 7 | 1099.36 | 80 | 10.65 | 1996 | 1701 | 2.10 / 975.16 | 5 | 56 |
3 | 13 | 71.44 | 20 | 14.06 | 460 | 129 | 2.22 / 975.29 | 5 | 91 |
4 | 13 | 16.64 | 20 | 14.15 | 367 | 104 | 2.33 / 975.39 | 5 | 87 |
5 | 8 | -0.24 | 216 | 14.16 | 321 | 982 | 3.31 / 976.38 | 5 | 130 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 61 | 14.28 | 441 | 384 | 0.38 / 970.19 | 5 | 8 |
2 | 7 | 1093.36 | 80 | 10.64 | 1984 | 1689 | 2.07 / 971.88 | 5 | 55 |
3 | 13 | 72.64 | 20 | 14.07 | 458 | 129 | 2.20 / 972.00 | 5 | 89 |
4 | 13 | 18.80 | 20 | 14.17 | 364 | 103 | 2.30 / 972.11 | 5 | 87 |
5 | 8 | -0.56 | 213 | 14.18 | 317 | 957 | 3.26 / 973.07 | 5 | 131 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 61 | 14.10 | 448 | 385 | 0.39 / 962.13 | 5 | 10 |
2 | 7 | 2031.24 | 81 | 9.40 | 3322 | 2529 | 2.91 / 964.66 | 5 | 17 |
3 | 13 | 2082.96 | 20 | 12.35 | 3473 | 858 | 3.77 / 965.52 | 5 | 46 |
4 | 13 | 2036.28 | 20 | 12.49 | 3402 | 850 | 4.62 / 966.37 | 5 | 51 |
5 | 13 | 1954.28 | 20 | 12.57 | 3306 | 831 | 5.45 / 967.20 | 5 | 55 |
6 | 13 | 1654.12 | 20 | 12.83 | 2820 | 724 | 6.18 / 967.92 | 5 | 63 |
7 | 13 | 1021.24 | 20 | 13.24 | 1904 | 504 | 6.68 / 968.42 | 5 | 85 |
8 | 13 | 376.32 | 20 | 13.77 | 934 | 257 | 6.94 / 968.68 | 5 | 94 |
9 | 13 | 38.60 | 20 | 14.21 | 396 | 113 | 7.05 / 968.79 | 5 | 88 |
10 | 13 | 6.04 | 20 | 14.29 | 334 | 95 | 7.15 / 968.89 | 5 | 87 |
11 | 8 | -0.32 | 204 | 14.25 | 314 | 913 | 8.06 / 969.80 | 5 | 137 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 62 | 14.17 | 446 | 392 | 0.39 / 958.90 | 5 | 11 |
2 | 7 | 1075.68 | 80 | 10.66 | 1957 | 1669 | 2.06 / 960.57 | 11 | 58 |
3 | 13 | 59.48 | 20 | 14.07 | 422 | 119 | 2.18 / 960.68 | 5 | 88 |
4 | 13 | 16.44 | 20 | 14.18 | 344 | 98 | 2.28 / 960.78 | 5 | 83 |
5 | 13 | 3.28 | 20 | 14.16 | 321 | 91 | 2.37 / 960.87 | 5 | 83 |
6 | 8 | -0.40 | 194 | 14.17 | 307 | 844 | 3.21 / 961.72 | 5 | 134 |
7 | 14 | -0.40 | 6 | 14.13 | 310 | 26 | 3.24 / 961.74 | 27 | 136 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 62 | 14.17 | 439 | 386 | 0.39 / 955.65 | 5 | 10 |
2 | 7 | 1080.92 | 80 | 10.70 | 1955 | 1673 | 2.06 / 957.32 | 10 | 57 |
3 | 13 | 57.16 | 20 | 14.09 | 431 | 121 | 2.18 / 957.44 | 5 | 89 |
4 | 13 | 14.80 | 20 | 14.17 | 350 | 99 | 2.28 / 957.54 | 5 | 86 |
5 | 8 | -0.32 | 216 | 14.13 | 316 | 964 | 3.24 / 958.51 | 5 | 137 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 61 | 14.28 | 443 | 386 | 0.39 / 952.41 | 5 | 9 |
2 | 7 | 1081.60 | 81 | 10.67 | 1956 | 1691 | 2.08 / 954.10 | 9 | 56 |
3 | 13 | 55.36 | 20 | 14.12 | 412 | 116 | 2.19 / 954.21 | 5 | 90 |
4 | 13 | 15.40 | 20 | 14.19 | 344 | 98 | 2.29 / 954.31 | 5 | 87 |
5 | 8 | -0.60 | 216 | 14.15 | 311 | 951 | 3.24 / 955.26 | 5 | 134 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 61 | 14.15 | 440 | 380 | 0.38 / 944.45 | 5 | 10 |
2 | 7 | 2008.04 | 80 | 9.45 | 3287 | 2485 | 2.86 / 946.93 | 10 | 19 |
3 | 13 | 2063.08 | 20 | 12.33 | 3439 | 848 | 3.71 / 947.78 | 5 | 47 |
4 | 13 | 2018.64 | 20 | 12.46 | 3402 | 848 | 4.56 / 948.63 | 5 | 52 |
5 | 13 | 1936.28 | 20 | 12.56 | 3274 | 822 | 5.38 / 949.45 | 5 | 56 |
6 | 13 | 1630.72 | 20 | 12.85 | 2750 | 707 | 6.09 / 950.16 | 5 | 63 |
7 | 13 | 986.80 | 20 | 13.26 | 1844 | 489 | 6.58 / 950.65 | 5 | 86 |
8 | 13 | 345.92 | 20 | 13.80 | 878 | 242 | 6.82 / 950.89 | 5 | 95 |
9 | 13 | 30.08 | 20 | 14.23 | 374 | 106 | 6.93 / 951.00 | 5 | 90 |
10 | 13 | 16.24 | 20 | 14.22 | 351 | 100 | 7.03 / 951.10 | 5 | 91 |
11 | 8 | -0.48 | 205 | 14.21 | 317 | 923 | 7.95 / 952.02 | 5 | 136 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 62 | 14.16 | 458 | 402 | 0.40 / 941.20 | 5 | 10 |
2 | 7 | 1080.00 | 81 | 10.66 | 1957 | 1690 | 2.09 / 942.89 | 10 | 57 |
3 | 13 | 57.16 | 20 | 14.09 | 415 | 117 | 2.21 / 943.01 | 5 | 90 |
4 | 13 | 13.60 | 20 | 14.17 | 343 | 97 | 2.31 / 943.11 | 5 | 87 |
5 | 8 | -0.36 | 216 | 14.12 | 315 | 961 | 3.27 / 944.07 | 5 | 135 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 62 | 14.17 | 468 | 411 | 0.41 / 937.90 | 5 | 11 |
2 | 7 | 1072.56 | 81 | 10.74 | 1954 | 1700 | 2.11 / 939.60 | 11 | 57 |
3 | 13 | 51.44 | 20 | 14.09 | 431 | 121 | 2.23 / 939.72 | 5 | 89 |
4 | 13 | 12.24 | 20 | 14.14 | 358 | 101 | 2.33 / 939.82 | 5 | 86 |
5 | 8 | -0.44 | 213 | 14.12 | 326 | 980 | 3.31 / 940.80 | 5 | 135 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 61 | 14.27 | 446 | 388 | 0.39 / 934.59 | 5 | 10 |
2 | 7 | 1081.44 | 80 | 10.67 | 1968 | 1680 | 2.07 / 936.27 | 10 | 56 |
3 | 13 | 61.40 | 20 | 14.08 | 442 | 124 | 2.19 / 936.40 | 5 | 89 |
4 | 13 | 16.80 | 20 | 14.19 | 363 | 103 | 2.30 / 936.50 | 5 | 86 |
5 | 8 | -0.56 | 216 | 14.14 | 324 | 990 | 3.29 / 937.49 | 5 | 135 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 61 | 14.14 | 453 | 391 | 0.39 / 926.59 | 5 | 11 |
2 | 3 | 1032.44 | 1 | 12.08 | 1980 | 24 | 0.41 / 926.61 | 5 | 5 |
3 | 7 | 2005.80 | 81 | 9.52 | 3285 | 2533 | 2.95 / 929.15 | 5 | 20 |
4 | 13 | 2053.48 | 20 | 12.35 | 3419 | 844 | 3.79 / 929.99 | 5 | 48 |
5 | 13 | 2003.04 | 20 | 12.48 | 3358 | 838 | 4.63 / 930.83 | 5 | 53 |
6 | 13 | 1917.76 | 20 | 12.60 | 3239 | 816 | 5.45 / 931.65 | 5 | 57 |
7 | 13 | 1612.20 | 20 | 12.86 | 2761 | 710 | 6.16 / 932.36 | 5 | 65 |
8 | 13 | 963.72 | 20 | 13.28 | 1813 | 482 | 6.64 / 932.84 | 5 | 86 |
9 | 13 | 318.20 | 20 | 13.79 | 855 | 236 | 6.87 / 933.07 | 5 | 96 |
10 | 13 | 42.68 | 20 | 14.22 | 403 | 115 | 6.99 / 933.19 | 5 | 91 |
11 | 8 | -0.28 | 225 | 14.22 | 317 | 1014 | 8.00 / 934.20 | 5 | 135 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 62 | 14.16 | 444 | 390 | 0.39 / 923.35 | 5 | 10 |
2 | 7 | 1075.60 | 80 | 10.71 | 1946 | 1667 | 2.06 / 925.02 | 10 | 58 |
3 | 13 | 62.28 | 20 | 14.06 | 431 | 121 | 2.18 / 925.14 | 5 | 88 |
4 | 13 | 14.36 | 20 | 14.19 | 348 | 99 | 2.28 / 925.24 | 5 | 85 |
5 | 8 | -0.32 | 216 | 14.13 | 315 | 961 | 3.24 / 926.20 | 5 | 141 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 62 | 14.19 | 447 | 393 | 0.39 / 920.15 | 5 | 13 |
2 | 7 | 1055.88 | 81 | 10.86 | 1895 | 1667 | 2.06 / 921.81 | 13 | 58 |
3 | 13 | 86.80 | 20 | 14.06 | 474 | 133 | 2.19 / 921.95 | 5 | 91 |
4 | 8 | -0.28 | 232 | 14.17 | 309 | 1016 | 3.21 / 922.96 | 5 | 131 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 61 | 14.21 | 453 | 393 | 0.39 / 916.91 | 5 | 12 |
2 | 7 | 1065.24 | 80 | 10.75 | 1953 | 1680 | 2.07 / 918.59 | 12 | 58 |
3 | 13 | 100.08 | 20 | 14.04 | 497 | 140 | 2.21 / 918.73 | 5 | 90 |
4 | 8 | -0.32 | 235 | 14.19 | 307 | 1024 | 3.24 / 919.75 | 5 | 139 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 62 | 14.13 | 455 | 399 | 0.40 / 908.89 | 5 | 15 |
2 | 3 | 955.96 | -1 | 14.13 | 455 | 0 | 0.00 / 908.89 | 5 | 15 |
3 | 7 | 2006.32 | 80 | 9.52 | 3290 | 2506 | 2.90 / 911.40 | 15 | 19 |
4 | 13 | 2060.12 | 20 | 12.31 | 3434 | 845 | 3.75 / 912.25 | 5 | 47 |
5 | 13 | 2012.76 | 20 | 12.45 | 3371 | 839 | 4.59 / 913.08 | 5 | 51 |
6 | 13 | 1930.24 | 20 | 12.57 | 3254 | 818 | 5.41 / 913.90 | 5 | 56 |
7 | 13 | 1622.52 | 20 | 12.80 | 2804 | 718 | 6.12 / 914.62 | 5 | 65 |
8 | 13 | 972.64 | 20 | 13.24 | 1839 | 487 | 6.61 / 915.11 | 5 | 86 |
9 | 13 | 426.28 | 20 | 13.69 | 1012 | 277 | 6.89 / 915.38 | 5 | 95 |
10 | 13 | 43.72 | 20 | 14.20 | 402 | 114 | 7.00 / 915.50 | 5 | 86 |
11 | 8 | -0.24 | 225 | 14.23 | 318 | 1018 | 8.02 / 916.52 | 5 | 132 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 62 | 14.12 | 463 | 405 | 0.41 / 905.66 | 5 | 16 |
2 | 7 | 1046.36 | 81 | 10.75 | 1900 | 1654 | 2.06 / 907.31 | 16 | 57 |
3 | 13 | 87.04 | 20 | 14.05 | 478 | 134 | 2.19 / 907.45 | 5 | 87 |
4 | 8 | -0.16 | 235 | 14.15 | 315 | 1047 | 3.24 / 908.50 | 5 | 132 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 62 | 14.11 | 454 | 397 | 0.40 / 902.41 | 5 | 16 |
2 | 7 | 1051.92 | 80 | 10.86 | 1913 | 1662 | 2.06 / 904.08 | 16 | 57 |
3 | 13 | 95.08 | 20 | 14.05 | 479 | 135 | 2.19 / 904.21 | 5 | 87 |
4 | 8 | -0.20 | 235 | 14.15 | 314 | 1044 | 3.24 / 905.25 | 5 | 132 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 61 | 14.20 | 472 | 409 | 0.41 / 899.08 | 5 | 14 |
2 | 7 | 1088.48 | 81 | 10.81 | 1990 | 1742 | 2.15 / 900.83 | 5 | 56 |
3 | 13 | 116.68 | 20 | 14.05 | 520 | 146 | 2.30 / 900.97 | 5 | 86 |
4 | 8 | -0.12 | 235 | 14.20 | 313 | 1044 | 3.34 / 902.02 | 5 | 149 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 62 | 14.13 | 466 | 408 | 0.41 / 891.00 | 5 | 14 |
2 | 7 | 2006.08 | 80 | 9.44 | 3293 | 2487 | 2.90 / 893.49 | 14 | 17 |
3 | 13 | 2062.12 | 20 | 12.24 | 3445 | 843 | 3.74 / 894.33 | 5 | 45 |
4 | 13 | 2016.44 | 20 | 12.43 | 3409 | 847 | 4.59 / 895.18 | 5 | 49 |
5 | 13 | 1935.80 | 20 | 12.56 | 3249 | 816 | 5.40 / 895.99 | 5 | 54 |
6 | 13 | 1631.36 | 20 | 12.81 | 2803 | 718 | 6.12 / 896.71 | 5 | 65 |
7 | 13 | 1190.04 | 20 | 13.09 | 2157 | 565 | 6.68 / 897.28 | 5 | 80 |
8 | 13 | 433.28 | 20 | 13.71 | 1030 | 282 | 6.97 / 897.56 | 5 | 92 |
9 | 13 | 48.60 | 20 | 14.25 | 401 | 114 | 7.08 / 897.67 | 5 | 78 |
10 | 8 | -0.12 | 225 | 14.25 | 312 | 1000 | 8.08 / 898.67 | 5 | 131 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 62 | 14.11 | 459 | 402 | 0.40 / 887.75 | 5 | 14 |
2 | 7 | 1066.16 | 80 | 10.69 | 1946 | 1664 | 2.07 / 889.41 | 14 | 56 |
3 | 13 | 104.36 | 20 | 14.03 | 491 | 138 | 2.20 / 889.55 | 5 | 77 |
4 | 13 | 24.16 | 20 | 14.24 | 352 | 100 | 2.30 / 889.65 | 5 | 71 |
5 | 8 | -0.12 | 216 | 14.20 | 307 | 942 | 3.25 / 890.59 | 5 | 139 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 62 | 14.13 | 462 | 405 | 0.40 / 884.53 | 5 | 15 |
2 | 7 | 1059.52 | 80 | 10.81 | 1925 | 1665 | 2.07 / 886.20 | 15 | 56 |
3 | 13 | 98.28 | 20 | 14.08 | 494 | 139 | 2.21 / 886.34 | 5 | 75 |
4 | 8 | -0.08 | 232 | 14.20 | 307 | 1011 | 3.22 / 887.35 | 5 | 133 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 63 | 14.21 | 459 | 411 | 0.41 / 881.23 | 5 | 12 |
2 | 3 | 957.92 | -1 | 14.21 | 459 | 0 | 0.00 / 881.23 | 5 | 12 |
3 | 7 | 1087.04 | 81 | 10.88 | 1980 | 1745 | 2.16 / 882.98 | 12 | 56 |
4 | 13 | 108.88 | 20 | 14.09 | 492 | 139 | 2.29 / 883.12 | 5 | 78 |
5 | 8 | -0.08 | 232 | 14.20 | 307 | 1011 | 3.31 / 884.13 | 5 | 137 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 62 | 14.14 | 457 | 401 | 0.40 / 873.14 | 5 | 15 |
2 | 7 | 2030.88 | 80 | 9.55 | 3353 | 2562 | 2.96 / 875.70 | 15 | 16 |
3 | 13 | 2081.16 | 20 | 12.22 | 3476 | 850 | 3.81 / 876.55 | 5 | 43 |
4 | 13 | 2031.68 | 20 | 12.37 | 3416 | 845 | 4.66 / 877.39 | 5 | 49 |
5 | 13 | 1946.52 | 20 | 12.51 | 3306 | 827 | 5.48 / 878.22 | 5 | 53 |
6 | 13 | 1541.20 | 20 | 12.84 | 2673 | 686 | 6.17 / 878.91 | 5 | 65 |
7 | 13 | 1024.60 | 20 | 13.17 | 1921 | 506 | 6.68 / 879.41 | 5 | 83 |
8 | 13 | 376.48 | 20 | 13.79 | 924 | 255 | 6.93 / 879.67 | 5 | 90 |
9 | 13 | 71.20 | 20 | 14.21 | 441 | 125 | 7.06 / 879.79 | 5 | 77 |
10 | 8 | -0.08 | 228 | 14.25 | 316 | 1027 | 8.08 / 880.82 | 5 | 143 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 62 | 14.12 | 477 | 418 | 0.42 / 869.85 | 5 | 13 |
2 | 7 | 1085.96 | 80 | 10.77 | 1978 | 1704 | 2.12 / 871.55 | 5 | 56 |
3 | 13 | 118.20 | 20 | 14.00 | 519 | 145 | 2.27 / 871.70 | 5 | 79 |
4 | 8 | -0.08 | 237 | 14.17 | 309 | 1038 | 3.30 / 872.74 | 5 | 136 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 61 | 14.15 | 471 | 407 | 0.41 / 866.48 | 5 | 13 |
2 | 7 | 1091.24 | 80 | 10.91 | 1998 | 1744 | 2.15 / 868.22 | 5 | 57 |
3 | 13 | 111.16 | 20 | 14.04 | 517 | 145 | 2.30 / 868.37 | 5 | 79 |
4 | 13 | 22.00 | 20 | 14.23 | 356 | 101 | 2.40 / 868.47 | 5 | 73 |
5 | 8 | -0.20 | 216 | 14.19 | 315 | 965 | 3.36 / 869.43 | 5 | 139 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 61 | 14.20 | 482 | 418 | 0.42 / 863.04 | 5 | 11 |
2 | 3 | 1064.96 | 2 | 12.33 | 2001 | 49 | 0.47 / 863.09 | 5 | 27 |
3 | 7 | 1118.60 | 81 | 11.04 | 2017 | 1804 | 2.27 / 864.90 | 27 | 57 |
4 | 13 | 79.32 | 20 | 14.13 | 456 | 129 | 2.40 / 865.03 | 5 | 75 |
5 | 8 | -0.20 | 232 | 14.20 | 317 | 1044 | 3.44 / 866.07 | 5 | 132 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 62 | 14.11 | 466 | 408 | 0.41 / 855.05 | 5 | 14 |
2 | 7 | 2007.24 | 80 | 9.68 | 3334 | 2582 | 2.99 / 857.63 | 14 | 17 |
3 | 13 | 2051.20 | 20 | 12.18 | 3447 | 840 | 3.83 / 858.47 | 5 | 43 |
4 | 13 | 1998.24 | 20 | 12.39 | 3355 | 831 | 4.66 / 859.30 | 5 | 50 |
5 | 13 | 1911.28 | 20 | 12.51 | 3246 | 812 | 5.47 / 860.12 | 5 | 55 |
6 | 13 | 1493.80 | 20 | 12.85 | 2601 | 668 | 6.14 / 860.79 | 5 | 67 |
7 | 13 | 954.92 | 20 | 13.22 | 1832 | 484 | 6.63 / 861.27 | 5 | 85 |
8 | 13 | 298.40 | 20 | 13.83 | 840 | 232 | 6.86 / 861.50 | 5 | 90 |
9 | 13 | 47.20 | 20 | 14.25 | 403 | 115 | 6.97 / 861.62 | 5 | 76 |
10 | 8 | -0.12 | 223 | 14.24 | 318 | 1010 | 7.98 / 862.63 | 5 | 137 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 61 | 14.06 | 461 | 395 | 0.40 / 851.69 | 5 | 16 |
2 | 3 | 1033.16 | 1 | 12.09 | 1948 | 24 | 0.42 / 851.72 | 5 | 5 |
3 | 7 | 1106.40 | 80 | 10.85 | 1993 | 1730 | 2.15 / 853.45 | 5 | 57 |
4 | 13 | 123.44 | 20 | 14.00 | 532 | 149 | 2.30 / 853.60 | 5 | 83 |
5 | 8 | -0.12 | 235 | 14.16 | 315 | 1048 | 3.35 / 854.64 | 5 | 136 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 62 | 14.13 | 467 | 409 | 0.41 / 848.43 | 5 | 17 |
2 | 3 | 956.52 | -1 | 14.13 | 467 | 0 | 0.00 / 848.43 | 5 | 17 |
3 | 7 | 1079.52 | 80 | 10.97 | 1966 | 1725 | 2.13 / 850.16 | 17 | 58 |
4 | 13 | 61.96 | 20 | 14.12 | 420 | 119 | 2.25 / 850.27 | 5 | 80 |
5 | 8 | -0.12 | 232 | 14.15 | 312 | 1024 | 3.28 / 851.30 | 5 | 133 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 63 | 14.20 | 466 | 417 | 0.42 / 845.09 | 5 | 12 |
2 | 3 | 964.48 | -1 | 14.20 | 466 | 0 | 0.00 / 845.09 | 5 | 12 |
3 | 7 | 1090.68 | 81 | 11.08 | 1973 | 1771 | 2.19 / 846.86 | 12 | 59 |
4 | 13 | 52.20 | 20 | 14.14 | 411 | 116 | 2.30 / 846.97 | 5 | 85 |
5 | 8 | -0.20 | 232 | 14.12 | 320 | 1048 | 3.35 / 848.02 | 5 | 132 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 62 | 14.09 | 458 | 400 | 0.40 / 836.92 | 5 | 14 |
2 | 7 | 2031.28 | 80 | 9.77 | 3352 | 2620 | 3.02 / 839.54 | 14 | 17 |
3 | 13 | 2077.00 | 20 | 12.15 | 3454 | 839 | 3.86 / 840.38 | 5 | 43 |
4 | 13 | 2024.64 | 20 | 12.33 | 3398 | 838 | 4.70 / 841.22 | 5 | 48 |
5 | 13 | 1937.12 | 20 | 12.44 | 3287 | 818 | 5.52 / 842.04 | 5 | 52 |
6 | 13 | 1628.36 | 20 | 12.77 | 2758 | 704 | 6.22 / 842.74 | 5 | 62 |
7 | 13 | 992.88 | 20 | 13.19 | 1852 | 489 | 6.71 / 843.23 | 5 | 84 |
8 | 13 | 445.84 | 20 | 13.67 | 1035 | 283 | 6.99 / 843.51 | 5 | 93 |
9 | 13 | 46.44 | 20 | 14.21 | 407 | 116 | 7.11 / 843.63 | 5 | 87 |
10 | 8 | -0.32 | 228 | 14.17 | 322 | 1040 | 8.15 / 844.67 | 5 | 140 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 62 | 14.14 | 458 | 402 | 0.40 / 833.67 | 5 | 13 |
2 | 7 | 1050.12 | 80 | 10.97 | 1910 | 1676 | 2.08 / 835.35 | 13 | 57 |
3 | 13 | 79.08 | 20 | 14.03 | 463 | 130 | 2.21 / 835.48 | 5 | 86 |
4 | 8 | -0.36 | 232 | 14.10 | 319 | 1044 | 3.25 / 836.52 | 5 | 133 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 62 | 14.18 | 469 | 412 | 0.41 / 830.33 | 5 | 10 |
2 | 7 | 1095.40 | 80 | 10.97 | 1988 | 1745 | 2.16 / 832.07 | 5 | 56 |
3 | 13 | 63.36 | 20 | 14.08 | 440 | 124 | 2.28 / 832.20 | 5 | 82 |
4 | 8 | -0.16 | 235 | 14.12 | 324 | 1075 | 3.36 / 833.27 | 5 | 139 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 62 | 14.24 | 464 | 410 | 0.41 / 826.85 | 5 | 9 |
2 | 3 | 1037.32 | 1 | 11.94 | 1960 | 23 | 0.43 / 826.87 | 5 | 6 |
3 | 7 | 1104.72 | 81 | 11.16 | 2025 | 1831 | 2.26 / 828.70 | 6 | 58 |
4 | 13 | 102.92 | 20 | 14.07 | 512 | 144 | 2.41 / 828.84 | 5 | 81 |
5 | 8 | -0.16 | 235 | 14.18 | 321 | 1070 | 3.48 / 829.91 | 5 | 152 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 62 | 14.14 | 461 | 404 | 0.40 / 818.95 | 5 | 10 |
2 | 7 | 2007.92 | 80 | 9.80 | 3318 | 2601 | 3.01 / 821.55 | 5 | 17 |
3 | 13 | 2053.76 | 20 | 12.08 | 3441 | 831 | 3.84 / 822.38 | 5 | 42 |
4 | 13 | 2001.32 | 20 | 12.28 | 3357 | 824 | 4.66 / 823.21 | 5 | 47 |
5 | 13 | 1914.24 | 20 | 12.40 | 3235 | 802 | 5.46 / 824.01 | 5 | 52 |
6 | 13 | 1393.16 | 20 | 12.88 | 2451 | 631 | 6.09 / 824.64 | 5 | 69 |
7 | 13 | 977.68 | 20 | 13.18 | 1855 | 489 | 6.58 / 825.13 | 5 | 83 |
8 | 13 | 318.16 | 20 | 13.82 | 843 | 233 | 6.82 / 825.36 | 5 | 88 |
9 | 13 | 55.88 | 20 | 14.26 | 402 | 115 | 6.93 / 825.48 | 5 | 67 |
10 | 8 | 0.00 | 220 | 14.28 | 306 | 961 | 7.89 / 826.44 | 5 | 130 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 62 | 14.16 | 462 | 406 | 0.41 / 815.67 | 5 | 10 |
2 | 7 | 1086.92 | 80 | 10.98 | 1956 | 1718 | 2.12 / 817.39 | 10 | 55 |
3 | 13 | 111.96 | 20 | 13.98 | 507 | 142 | 2.27 / 817.53 | 5 | 82 |
4 | 8 | -0.16 | 232 | 14.15 | 308 | 1011 | 3.28 / 818.54 | 5 | 131 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 62 | 14.13 | 474 | 415 | 0.42 / 812.36 | 5 | 10 |
2 | 7 | 1089.48 | 80 | 11.09 | 1972 | 1750 | 2.16 / 814.11 | 5 | 58 |
3 | 13 | 60.96 | 20 | 14.11 | 427 | 120 | 2.29 / 814.23 | 5 | 80 |
4 | 8 | -0.20 | 232 | 14.14 | 317 | 1040 | 3.33 / 815.27 | 5 | 133 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 61 | 14.17 | 458 | 396 | 0.40 / 808.93 | 5 | 9 |
2 | 3 | 1020.12 | 1 | 10.17 | 1929 | 20 | 0.42 / 808.95 | 5 | 5 |
3 | 7 | 1100.72 | 80 | 11.36 | 1988 | 1807 | 2.22 / 810.76 | 5 | 59 |
4 | 13 | 58.88 | 20 | 14.12 | 431 | 122 | 2.34 / 810.88 | 5 | 82 |
5 | 8 | -0.44 | 233 | 14.14 | 322 | 1061 | 3.40 / 811.94 | 5 | 140 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 61 | 14.08 | 459 | 394 | 0.39 / 800.81 | 5 | 10 |
2 | 3 | 1021.16 | 1 | 11.54 | 1941 | 22 | 0.42 / 800.84 | 5 | 5 |
3 | 7 | 2029.84 | 81 | 9.87 | 3362 | 2688 | 3.10 / 803.52 | 5 | 16 |
4 | 13 | 2065.36 | 20 | 12.01 | 3447 | 828 | 3.93 / 804.35 | 5 | 42 |
5 | 13 | 2005.88 | 20 | 12.22 | 3362 | 822 | 4.75 / 805.17 | 5 | 47 |
6 | 13 | 1914.92 | 20 | 12.35 | 3242 | 801 | 5.55 / 805.97 | 5 | 52 |
7 | 13 | 1602.12 | 20 | 12.68 | 2762 | 700 | 6.26 / 806.68 | 5 | 62 |
8 | 13 | 1052.04 | 20 | 13.10 | 1955 | 512 | 6.77 / 807.19 | 5 | 80 |
9 | 13 | 294.08 | 20 | 13.79 | 826 | 228 | 7.00 / 807.42 | 5 | 90 |
10 | 13 | 41.12 | 20 | 14.18 | 406 | 115 | 7.11 / 807.53 | 5 | 84 |
11 | 8 | -0.36 | 220 | 14.17 | 323 | 1007 | 8.12 / 808.54 | 5 | 129 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 62 | 14.12 | 459 | 402 | 0.40 / 797.46 | 5 | 10 |
2 | 7 | 1091.64 | 81 | 11.06 | 1982 | 1776 | 2.18 / 799.24 | 5 | 58 |
3 | 13 | 51.64 | 20 | 14.04 | 416 | 117 | 2.29 / 799.36 | 5 | 85 |
4 | 13 | 31.72 | 20 | 14.07 | 381 | 107 | 2.40 / 799.46 | 5 | 84 |
5 | 8 | -0.28 | 213 | 14.09 | 319 | 957 | 3.36 / 800.42 | 5 | 137 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 61 | 14.12 | 450 | 388 | 0.39 / 794.11 | 5 | 9 |
2 | 7 | 1089.92 | 81 | 11.15 | 1973 | 1782 | 2.17 / 795.89 | 5 | 60 |
3 | 13 | 51.44 | 20 | 14.09 | 423 | 119 | 2.29 / 796.01 | 5 | 86 |
4 | 8 | -0.32 | 232 | 14.09 | 321 | 1049 | 3.34 / 797.06 | 5 | 138 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 63 | 14.20 | 449 | 402 | 0.40 / 790.75 | 5 | 8 |
2 | 3 | 953.60 | -1 | 14.20 | 449 | 0 | 0.00 / 790.75 | 5 | 8 |
3 | 7 | 1088.72 | 80 | 11.33 | 1998 | 1811 | 2.21 / 792.56 | 8 | 61 |
4 | 13 | 47.76 | 20 | 14.11 | 410 | 116 | 2.33 / 792.67 | 5 | 84 |
5 | 8 | -0.48 | 232 | 14.12 | 320 | 1048 | 3.38 / 793.72 | 5 | 143 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 63 | 14.14 | 449 | 400 | 0.40 / 782.79 | 5 | 8 |
2 | 3 | 961.80 | -1 | 14.14 | 449 | 0 | 0.00 / 782.79 | 5 | 8 |
3 | 7 | 2006.84 | 80 | 9.89 | 3314 | 2622 | 3.02 / 785.42 | 8 | 16 |
4 | 13 | 2046.88 | 20 | 11.94 | 3404 | 813 | 3.83 / 786.23 | 5 | 40 |
5 | 13 | 1990.68 | 20 | 12.15 | 3343 | 812 | 4.65 / 787.04 | 5 | 46 |
6 | 13 | 1900.92 | 20 | 12.34 | 3221 | 795 | 5.44 / 787.84 | 5 | 51 |
7 | 13 | 1593.96 | 20 | 12.63 | 2771 | 700 | 6.14 / 788.54 | 5 | 62 |
8 | 13 | 937.72 | 20 | 13.15 | 1796 | 472 | 6.61 / 789.01 | 5 | 83 |
9 | 13 | 287.36 | 20 | 13.81 | 801 | 221 | 6.84 / 789.23 | 5 | 90 |
10 | 13 | 42.48 | 20 | 14.19 | 402 | 114 | 6.95 / 789.34 | 5 | 86 |
11 | 8 | -0.24 | 223 | 14.15 | 318 | 1003 | 7.95 / 790.35 | 5 | 137 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 63 | 14.12 | 455 | 405 | 0.40 / 779.44 | 5 | 7 |
2 | 3 | 965.76 | -1 | 14.12 | 455 | 0 | 0.00 / 779.44 | 5 | 7 |
3 | 7 | 1100.40 | 81 | 11.02 | 2006 | 1791 | 2.20 / 781.23 | 7 | 58 |
4 | 13 | 51.48 | 20 | 14.03 | 418 | 117 | 2.31 / 781.35 | 5 | 85 |
5 | 13 | 27.80 | 20 | 14.08 | 374 | 105 | 2.42 / 781.45 | 5 | 84 |
6 | 8 | -0.24 | 211 | 14.08 | 317 | 942 | 3.36 / 782.39 | 5 | 130 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 63 | 14.13 | 449 | 400 | 0.40 / 776.14 | 5 | 7 |
2 | 7 | 1048.88 | 81 | 11.19 | 1918 | 1738 | 2.14 / 777.88 | 7 | 60 |
3 | 13 | 43.44 | 20 | 14.10 | 406 | 114 | 2.25 / 777.99 | 5 | 85 |
4 | 13 | 24.64 | 20 | 14.09 | 374 | 105 | 2.36 / 778.10 | 5 | 83 |
5 | 8 | -0.48 | 211 | 14.11 | 315 | 938 | 3.30 / 779.03 | 5 | 139 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 63 | 14.19 | 443 | 396 | 0.40 / 772.86 | 6 | 6 |
2 | 7 | 1055.80 | 80 | 11.50 | 1898 | 1746 | 2.14 / 774.61 | 6 | 62 |
3 | 13 | 45.44 | 20 | 14.13 | 396 | 112 | 2.25 / 774.72 | 5 | 84 |
4 | 13 | 24.08 | 20 | 14.14 | 357 | 101 | 2.36 / 774.82 | 5 | 83 |
5 | 8 | -0.64 | 209 | 14.14 | 311 | 919 | 3.27 / 775.74 | 5 | 136 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 63 | 14.14 | 450 | 401 | 0.40 / 764.89 | 5 | 7 |
2 | 7 | 2006.28 | 80 | 9.94 | 3330 | 2648 | 3.05 / 767.54 | 7 | 17 |
3 | 13 | 2049.56 | 20 | 11.91 | 3422 | 815 | 3.86 / 768.35 | 5 | 40 |
4 | 13 | 1995.92 | 20 | 12.12 | 3362 | 815 | 4.68 / 769.17 | 5 | 45 |
5 | 13 | 1908.52 | 20 | 12.30 | 3222 | 793 | 5.47 / 769.96 | 5 | 52 |
6 | 13 | 1594.92 | 20 | 12.62 | 2739 | 691 | 6.16 / 770.65 | 5 | 61 |
7 | 13 | 949.60 | 20 | 13.15 | 1787 | 470 | 6.63 / 771.12 | 5 | 83 |
8 | 13 | 307.12 | 20 | 13.76 | 839 | 231 | 6.86 / 771.35 | 5 | 91 |
9 | 13 | 46.28 | 20 | 14.20 | 406 | 115 | 6.98 / 771.47 | 5 | 82 |
10 | 8 | -0.36 | 225 | 14.20 | 312 | 997 | 7.98 / 772.46 | 5 | 138 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 63 | 14.14 | 448 | 399 | 0.40 / 761.63 | 6 | 7 |
2 | 7 | 1065.80 | 80 | 11.25 | 1909 | 1718 | 2.12 / 763.35 | 7 | 58 |
3 | 13 | 84.40 | 20 | 14.00 | 449 | 126 | 2.24 / 763.47 | 5 | 84 |
4 | 13 | 22.60 | 20 | 14.15 | 348 | 98 | 2.34 / 763.57 | 5 | 77 |
5 | 8 | -0.32 | 213 | 14.13 | 304 | 915 | 3.26 / 764.49 | 5 | 143 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 63 | 14.21 | 454 | 406 | 0.41 / 758.32 | 6 | 7 |
2 | 7 | 1062.44 | 81 | 11.32 | 1916 | 1757 | 2.16 / 760.08 | 7 | 59 |
3 | 13 | 81.12 | 20 | 14.05 | 453 | 127 | 2.29 / 760.21 | 5 | 85 |
4 | 13 | 21.20 | 20 | 14.18 | 350 | 99 | 2.39 / 760.31 | 5 | 77 |
5 | 8 | -0.40 | 211 | 14.15 | 310 | 926 | 3.32 / 761.23 | 5 | 136 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 63 | 14.24 | 453 | 406 | 0.41 / 754.95 | 6 | 6 |
2 | 7 | 1062.80 | 81 | 11.54 | 1926 | 1800 | 2.21 / 756.75 | 6 | 63 |
3 | 13 | 74.64 | 20 | 14.07 | 460 | 129 | 2.34 / 756.88 | 5 | 84 |
4 | 8 | -0.48 | 230 | 14.16 | 318 | 1036 | 3.37 / 757.92 | 5 | 141 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 63 | 14.18 | 447 | 399 | 0.40 / 746.96 | 5 | 7 |
2 | 7 | 2029.20 | 80 | 9.95 | 3366 | 2679 | 3.08 / 749.64 | 7 | 16 |
3 | 13 | 2066.88 | 20 | 11.85 | 3448 | 817 | 3.90 / 750.45 | 5 | 39 |
4 | 13 | 2010.36 | 20 | 12.11 | 3362 | 814 | 4.71 / 751.27 | 5 | 45 |
5 | 13 | 1922.76 | 20 | 12.31 | 3221 | 793 | 5.50 / 752.06 | 5 | 50 |
6 | 13 | 1508.32 | 20 | 12.70 | 2603 | 661 | 6.16 / 752.72 | 5 | 64 |
7 | 13 | 965.92 | 20 | 13.13 | 1849 | 486 | 6.65 / 753.21 | 5 | 83 |
8 | 13 | 319.04 | 20 | 13.77 | 847 | 233 | 6.88 / 753.44 | 5 | 91 |
9 | 13 | 49.60 | 20 | 14.19 | 407 | 116 | 7.00 / 753.56 | 5 | 81 |
10 | 8 | -0.32 | 223 | 14.20 | 312 | 988 | 7.99 / 754.54 | 5 | 132 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 63 | 14.19 | 455 | 407 | 0.41 / 743.67 | 6 | 7 |
2 | 7 | 1075.72 | 80 | 11.32 | 1931 | 1749 | 2.16 / 745.41 | 7 | 59 |
3 | 13 | 89.04 | 20 | 14.01 | 473 | 133 | 2.29 / 745.55 | 5 | 83 |
4 | 13 | 22.12 | 20 | 14.18 | 348 | 99 | 2.39 / 745.65 | 5 | 77 |
5 | 8 | -0.40 | 211 | 14.13 | 306 | 912 | 3.30 / 746.56 | 5 | 136 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 63 | 14.22 | 444 | 398 | 0.40 / 740.36 | 6 | 7 |
2 | 7 | 1058.00 | 80 | 11.40 | 1913 | 1745 | 2.14 / 742.11 | 7 | 60 |
3 | 13 | 83.64 | 20 | 14.05 | 467 | 131 | 2.27 / 742.24 | 5 | 82 |
4 | 13 | 20.00 | 20 | 14.22 | 349 | 99 | 2.37 / 742.34 | 5 | 76 |
5 | 8 | -0.36 | 211 | 14.16 | 308 | 920 | 3.29 / 743.26 | 5 | 144 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 63 | 14.27 | 447 | 402 | 0.40 / 737.05 | 6 | 6 |
2 | 7 | 1079.64 | 80 | 11.69 | 1919 | 1795 | 2.20 / 738.84 | 5 | 62 |
3 | 13 | 50.16 | 20 | 14.14 | 404 | 114 | 2.31 / 738.96 | 5 | 79 |
4 | 13 | 27.28 | 20 | 14.17 | 361 | 102 | 2.41 / 739.06 | 5 | 77 |
5 | 8 | -0.40 | 209 | 14.17 | 306 | 906 | 3.32 / 739.97 | 5 | 131 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 63 | 14.17 | 465 | 415 | 0.42 / 729.21 | 6 | 7 |
2 | 7 | 2006.64 | 80 | 10.18 | 3316 | 2701 | 3.12 / 731.91 | 5 | 19 |
3 | 13 | 2035.08 | 20 | 11.96 | 3382 | 809 | 3.92 / 732.71 | 5 | 41 |
4 | 13 | 1973.68 | 20 | 12.20 | 3303 | 806 | 4.73 / 733.52 | 5 | 46 |
5 | 13 | 1881.60 | 20 | 12.32 | 3182 | 784 | 5.51 / 734.30 | 5 | 52 |
6 | 13 | 1463.68 | 20 | 12.73 | 2540 | 647 | 6.16 / 734.95 | 5 | 64 |
7 | 13 | 918.52 | 20 | 13.18 | 1748 | 461 | 6.62 / 735.41 | 5 | 82 |
8 | 13 | 162.68 | 20 | 14.00 | 592 | 166 | 6.79 / 735.58 | 5 | 88 |
9 | 13 | 41.84 | 20 | 14.25 | 390 | 111 | 6.90 / 735.69 | 5 | 78 |
10 | 8 | -0.40 | 220 | 14.22 | 306 | 957 | 7.86 / 736.65 | 5 | 141 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 63 | 14.14 | 461 | 411 | 0.41 / 725.85 | 5 | 7 |
2 | 7 | 1060.72 | 81 | 11.47 | 1933 | 1796 | 2.21 / 727.65 | 7 | 62 |
3 | 13 | 72.44 | 20 | 14.08 | 446 | 126 | 2.33 / 727.77 | 5 | 82 |
4 | 13 | 18.44 | 20 | 14.20 | 348 | 99 | 2.43 / 727.87 | 5 | 76 |
5 | 8 | -0.44 | 209 | 14.10 | 312 | 919 | 3.35 / 728.79 | 5 | 144 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 62 | 14.22 | 462 | 407 | 0.41 / 722.38 | 6 | 7 |
2 | 3 | 1023.68 | 1 | 11.53 | 1950 | 22 | 0.43 / 722.41 | 5 | 5 |
3 | 7 | 1100.00 | 81 | 11.49 | 1977 | 1840 | 2.27 / 724.25 | 5 | 61 |
4 | 13 | 92.80 | 20 | 14.06 | 494 | 139 | 2.41 / 724.39 | 5 | 84 |
5 | 13 | 22.68 | 20 | 14.21 | 365 | 104 | 2.51 / 724.49 | 5 | 76 |
6 | 8 | -0.44 | 211 | 14.15 | 318 | 949 | 3.46 / 725.44 | 5 | 133 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 62 | 14.22 | 456 | 402 | 0.40 / 718.88 | 6 | 6 |
2 | 3 | 1019.96 | 1 | 9.74 | 1903 | 19 | 0.42 / 718.89 | 5 | 5 |
3 | 7 | 1096.40 | 81 | 11.75 | 1990 | 1894 | 2.31 / 720.79 | 5 | 63 |
4 | 13 | 84.60 | 20 | 14.09 | 483 | 136 | 2.45 / 720.92 | 5 | 83 |
5 | 13 | 20.16 | 20 | 14.22 | 361 | 103 | 2.55 / 721.03 | 5 | 76 |
6 | 8 | -0.48 | 209 | 14.16 | 321 | 950 | 3.50 / 721.98 | 5 | 142 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 62 | 14.18 | 466 | 410 | 0.41 / 710.99 | 6 | 7 |
2 | 3 | 1024.64 | 1 | 12.01 | 1951 | 23 | 0.43 / 711.01 | 5 | 5 |
3 | 7 | 2007.00 | 81 | 10.30 | 3336 | 2783 | 3.22 / 713.80 | 5 | 20 |
4 | 13 | 2027.60 | 20 | 12.03 | 3406 | 819 | 4.04 / 714.61 | 5 | 42 |
5 | 13 | 1964.48 | 20 | 12.22 | 3307 | 808 | 4.84 / 715.42 | 5 | 47 |
6 | 13 | 1870.64 | 20 | 12.36 | 3190 | 789 | 5.63 / 716.21 | 5 | 52 |
7 | 13 | 1352.52 | 20 | 12.86 | 2381 | 612 | 6.25 / 716.82 | 5 | 68 |
8 | 13 | 815.68 | 20 | 13.29 | 1599 | 425 | 6.67 / 717.25 | 5 | 84 |
9 | 13 | 157.76 | 20 | 13.99 | 605 | 169 | 6.84 / 717.42 | 5 | 87 |
10 | 13 | 41.76 | 20 | 14.22 | 387 | 110 | 6.95 / 717.53 | 5 | 77 |
11 | 8 | -0.32 | 218 | 14.23 | 305 | 946 | 7.90 / 718.47 | 5 | 137 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 62 | 14.23 | 445 | 393 | 0.39 / 707.60 | 5 | 7 |
2 | 7 | 1067.88 | 81 | 11.61 | 1925 | 1810 | 2.20 / 709.41 | 7 | 62 |
3 | 13 | 72.40 | 20 | 14.06 | 454 | 128 | 2.33 / 709.54 | 5 | 82 |
4 | 13 | 17.20 | 20 | 14.20 | 353 | 100 | 2.43 / 709.64 | 5 | 76 |
5 | 8 | -0.52 | 209 | 14.10 | 318 | 937 | 3.37 / 710.58 | 5 | 133 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 62 | 14.20 | 458 | 403 | 0.40 / 704.27 | 5 | 7 |
2 | 7 | 1082.56 | 81 | 11.63 | 1936 | 1824 | 2.23 / 706.09 | 5 | 61 |
3 | 13 | 84.88 | 20 | 14.10 | 464 | 131 | 2.36 / 706.22 | 5 | 84 |
4 | 13 | 21.16 | 20 | 14.23 | 344 | 98 | 2.46 / 706.32 | 5 | 77 |
5 | 8 | -0.44 | 209 | 14.18 | 300 | 889 | 3.34 / 707.21 | 5 | 140 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 62 | 14.23 | 473 | 417 | 0.42 / 700.87 | 6 | 6 |
2 | 7 | 1082.96 | 80 | 11.84 | 1949 | 1846 | 2.26 / 702.72 | 5 | 64 |
3 | 13 | 80.52 | 20 | 14.12 | 463 | 131 | 2.39 / 702.85 | 5 | 83 |
4 | 13 | 19.12 | 20 | 14.24 | 353 | 101 | 2.49 / 702.95 | 5 | 77 |
5 | 8 | -0.48 | 209 | 14.17 | 310 | 918 | 3.41 / 703.87 | 5 | 143 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 62 | 14.22 | 441 | 389 | 0.39 / 692.93 | 5 | 7 |
2 | 7 | 2006.80 | 81 | 10.41 | 3338 | 2815 | 3.20 / 695.75 | 5 | 21 |
3 | 13 | 2015.12 | 20 | 12.08 | 3378 | 816 | 4.02 / 696.56 | 5 | 42 |
4 | 13 | 1948.96 | 20 | 12.31 | 3271 | 805 | 4.82 / 697.37 | 5 | 47 |
5 | 13 | 1853.76 | 20 | 12.41 | 3145 | 781 | 5.61 / 698.15 | 5 | 53 |
6 | 13 | 1318.80 | 20 | 12.88 | 2352 | 606 | 6.21 / 698.76 | 5 | 69 |
7 | 13 | 777.60 | 20 | 13.33 | 1541 | 411 | 6.62 / 699.17 | 5 | 85 |
8 | 13 | 120.20 | 20 | 14.07 | 549 | 154 | 6.78 / 699.32 | 5 | 85 |
9 | 13 | 30.52 | 20 | 14.24 | 396 | 113 | 6.89 / 699.43 | 5 | 77 |
10 | 8 | -0.32 | 216 | 14.16 | 333 | 1019 | 7.91 / 700.45 | 5 | 130 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 62 | 14.23 | 443 | 391 | 0.39 / 689.66 | 5 | 7 |
2 | 7 | 1062.92 | 80 | 11.70 | 1911 | 1789 | 2.18 / 691.45 | 7 | 63 |
3 | 13 | 74.16 | 20 | 14.11 | 435 | 123 | 2.30 / 691.57 | 5 | 82 |
4 | 13 | 17.32 | 20 | 14.21 | 330 | 94 | 2.40 / 691.66 | 5 | 77 |
5 | 8 | -0.40 | 209 | 14.12 | 299 | 882 | 3.28 / 692.55 | 5 | 144 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 62 | 14.16 | 461 | 405 | 0.40 / 686.34 | 5 | 7 |
2 | 7 | 1078.60 | 80 | 11.71 | 1943 | 1820 | 2.22 / 688.16 | 5 | 63 |
3 | 13 | 82.16 | 20 | 14.12 | 452 | 128 | 2.35 / 688.28 | 5 | 83 |
4 | 13 | 18.32 | 20 | 14.21 | 343 | 97 | 2.45 / 688.38 | 5 | 77 |
5 | 8 | -0.36 | 206 | 14.18 | 303 | 885 | 3.34 / 689.27 | 5 | 129 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 62 | 14.27 | 455 | 403 | 0.40 / 682.86 | 6 | 7 |
2 | 7 | 1087.08 | 81 | 11.90 | 1973 | 1902 | 2.30 / 684.76 | 5 | 64 |
3 | 13 | 44.56 | 20 | 14.19 | 416 | 118 | 2.42 / 684.88 | 5 | 79 |
4 | 13 | 23.04 | 20 | 14.18 | 374 | 106 | 2.53 / 684.99 | 5 | 77 |
5 | 8 | -0.48 | 206 | 14.15 | 324 | 944 | 3.47 / 685.93 | 5 | 133 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 62 | 14.16 | 451 | 396 | 0.40 / 675.10 | 5 | 7 |
2 | 7 | 2007.00 | 80 | 10.58 | 3329 | 2818 | 3.21 / 677.92 | 5 | 24 |
3 | 13 | 2009.36 | 20 | 12.20 | 3381 | 825 | 4.04 / 678.74 | 5 | 43 |
4 | 13 | 1942.80 | 20 | 12.37 | 3262 | 807 | 4.85 / 679.55 | 5 | 48 |
5 | 13 | 1847.56 | 20 | 12.51 | 3109 | 778 | 5.62 / 680.33 | 5 | 54 |
6 | 13 | 1310.84 | 20 | 12.95 | 2321 | 601 | 6.22 / 680.93 | 5 | 71 |
7 | 13 | 572.48 | 20 | 13.52 | 1245 | 337 | 6.56 / 681.26 | 5 | 89 |
8 | 13 | 80.36 | 20 | 14.15 | 470 | 133 | 6.69 / 681.40 | 5 | 81 |
9 | 13 | 22.52 | 20 | 14.24 | 368 | 105 | 6.80 / 681.50 | 5 | 76 |
10 | 8 | -0.40 | 213 | 14.19 | 317 | 958 | 7.76 / 682.46 | 5 | 131 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 62 | 14.23 | 453 | 400 | 0.40 / 671.74 | 5 | 7 |
2 | 7 | 1074.80 | 81 | 11.81 | 1930 | 1846 | 2.25 / 673.59 | 5 | 63 |
3 | 13 | 41.80 | 20 | 14.18 | 394 | 112 | 2.36 / 673.70 | 5 | 80 |
4 | 8 | -0.32 | 228 | 14.16 | 311 | 1004 | 3.36 / 674.70 | 5 | 142 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 62 | 14.24 | 458 | 404 | 0.40 / 668.36 | 5 | 7 |
2 | 7 | 1085.60 | 81 | 11.81 | 1924 | 1841 | 2.24 / 670.20 | 5 | 61 |
3 | 13 | 46.80 | 20 | 14.20 | 407 | 116 | 2.36 / 670.31 | 5 | 80 |
4 | 13 | 23.52 | 20 | 14.17 | 361 | 102 | 2.46 / 670.41 | 5 | 78 |
5 | 8 | -0.48 | 209 | 14.16 | 313 | 926 | 3.39 / 671.34 | 5 | 144 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 62 | 14.34 | 435 | 387 | 0.39 / 664.97 | 6 | 7 |
2 | 7 | 1075.32 | 81 | 11.95 | 1945 | 1883 | 2.27 / 666.85 | 5 | 64 |
3 | 13 | 40.16 | 20 | 14.23 | 383 | 109 | 2.38 / 666.96 | 5 | 78 |
4 | 8 | -0.48 | 228 | 14.19 | 307 | 993 | 3.37 / 667.95 | 5 | 152 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 61 | 14.23 | 461 | 400 | 0.40 / 657.17 | 5 | 8 |
2 | 3 | 1024.56 | 1 | 12.45 | 1960 | 24 | 0.42 / 657.20 | 5 | 5 |
3 | 7 | 2006.56 | 81 | 10.72 | 3325 | 2887 | 3.31 / 660.08 | 5 | 25 |
4 | 13 | 1996.08 | 20 | 12.29 | 3326 | 818 | 4.13 / 660.90 | 5 | 45 |
5 | 13 | 1926.44 | 20 | 12.44 | 3247 | 808 | 4.94 / 661.71 | 5 | 49 |
6 | 13 | 1831.36 | 20 | 12.54 | 3101 | 778 | 5.71 / 662.49 | 5 | 55 |
7 | 13 | 1193.96 | 20 | 13.05 | 2170 | 566 | 6.28 / 663.05 | 5 | 75 |
8 | 13 | 651.56 | 20 | 13.50 | 1333 | 360 | 6.64 / 663.41 | 5 | 85 |
9 | 13 | 98.24 | 20 | 14.13 | 484 | 137 | 6.78 / 663.55 | 5 | 84 |
10 | 13 | 21.40 | 20 | 14.27 | 352 | 100 | 6.88 / 663.65 | 5 | 77 |
11 | 8 | -0.32 | 211 | 14.20 | 310 | 929 | 7.81 / 664.58 | 5 | 129 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 61 | 14.22 | 461 | 400 | 0.40 / 653.79 | 5 | 9 |
2 | 7 | 1073.60 | 81 | 11.88 | 1922 | 1850 | 2.25 / 655.64 | 5 | 60 |
3 | 13 | 40.32 | 20 | 14.22 | 393 | 112 | 2.36 / 655.75 | 5 | 76 |
4 | 8 | -0.28 | 228 | 14.18 | 315 | 1018 | 3.38 / 656.77 | 5 | 145 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 61 | 14.22 | 464 | 402 | 0.40 / 650.44 | 5 | 9 |
2 | 7 | 1079.52 | 80 | 11.88 | 1945 | 1849 | 2.25 / 652.29 | 5 | 63 |
3 | 13 | 40.96 | 20 | 14.24 | 382 | 109 | 2.36 / 652.40 | 5 | 77 |
4 | 8 | -0.12 | 228 | 14.20 | 307 | 994 | 3.35 / 653.39 | 5 | 145 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 61 | 14.25 | 451 | 392 | 0.39 / 646.98 | 5 | 8 |
2 | 3 | 1023.44 | 1 | 11.11 | 1940 | 22 | 0.41 / 647.00 | 5 | 5 |
3 | 7 | 1084.20 | 80 | 11.99 | 1977 | 1896 | 2.31 / 648.90 | 5 | 63 |
4 | 13 | 44.04 | 20 | 14.23 | 395 | 112 | 2.42 / 649.01 | 5 | 77 |
5 | 8 | -0.28 | 228 | 14.19 | 317 | 1026 | 3.45 / 650.04 | 5 | 140 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 61 | 14.24 | 446 | 387 | 0.39 / 639.28 | 5 | 9 |
2 | 7 | 2006.16 | 81 | 10.86 | 3325 | 2925 | 3.31 / 642.20 | 5 | 26 |
3 | 13 | 1984.12 | 20 | 12.36 | 3315 | 819 | 4.13 / 643.02 | 5 | 45 |
4 | 13 | 1910.00 | 20 | 12.48 | 3222 | 804 | 4.94 / 643.83 | 5 | 50 |
5 | 13 | 1713.76 | 20 | 12.69 | 2917 | 740 | 5.68 / 644.57 | 5 | 59 |
6 | 13 | 1177.80 | 20 | 13.09 | 2113 | 553 | 6.23 / 645.12 | 5 | 76 |
7 | 13 | 539.48 | 20 | 13.60 | 1170 | 318 | 6.55 / 645.44 | 5 | 90 |
8 | 13 | 95.48 | 20 | 14.14 | 482 | 136 | 6.68 / 645.58 | 5 | 83 |
9 | 8 | -0.16 | 232 | 14.20 | 308 | 1015 | 7.70 / 646.59 | 5 | 138 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 61 | 14.25 | 451 | 392 | 0.39 / 635.93 | 5 | 9 |
2 | 7 | 1063.76 | 80 | 11.96 | 1919 | 1836 | 2.23 / 637.77 | 9 | 64 |
3 | 13 | 68.08 | 20 | 14.17 | 432 | 122 | 2.35 / 637.89 | 5 | 81 |
4 | 8 | -0.28 | 228 | 14.16 | 311 | 1004 | 3.35 / 638.89 | 5 | 134 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 63 | 14.21 | 462 | 414 | 0.41 / 632.62 | 5 | 10 |
2 | 3 | 928.40 | -1 | 14.21 | 462 | 0 | 0.00 / 632.62 | 5 | 10 |
3 | 7 | 1041.12 | 80 | 11.98 | 1892 | 1813 | 2.23 / 634.43 | 10 | 65 |
4 | 13 | 59.64 | 20 | 14.21 | 411 | 117 | 2.34 / 634.55 | 5 | 81 |
5 | 8 | -0.20 | 225 | 14.18 | 311 | 992 | 3.34 / 635.54 | 5 | 137 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 61 | 14.25 | 461 | 401 | 0.40 / 629.16 | 5 | 9 |
2 | 7 | 1076.96 | 80 | 12.04 | 1964 | 1892 | 2.29 / 631.05 | 5 | 65 |
3 | 13 | 39.36 | 20 | 14.25 | 392 | 112 | 2.40 / 631.17 | 5 | 78 |
4 | 8 | 0.08 | 228 | 14.15 | 321 | 1036 | 3.44 / 632.20 | 5 | 142 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 60 | 14.20 | 459 | 391 | 0.39 / 621.33 | 5 | 11 |
2 | 7 | 2029.00 | 81 | 10.96 | 3360 | 2983 | 3.37 / 624.31 | 5 | 28 |
3 | 13 | 2001.12 | 20 | 12.38 | 3359 | 832 | 4.21 / 625.14 | 5 | 45 |
4 | 13 | 1922.32 | 20 | 12.55 | 3228 | 810 | 5.02 / 625.95 | 5 | 50 |
5 | 13 | 1719.96 | 20 | 12.74 | 2881 | 734 | 5.75 / 626.69 | 5 | 56 |
6 | 13 | 1182.84 | 20 | 13.09 | 2163 | 566 | 6.32 / 627.25 | 5 | 75 |
7 | 13 | 530.96 | 20 | 13.61 | 1198 | 326 | 6.64 / 627.58 | 5 | 90 |
8 | 13 | 92.32 | 20 | 14.13 | 493 | 139 | 6.78 / 627.72 | 5 | 83 |
9 | 8 | 0.16 | 230 | 14.17 | 320 | 1043 | 7.82 / 628.76 | 5 | 131 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 61 | 14.19 | 491 | 425 | 0.43 / 617.83 | 5 | 12 |
2 | 3 | 1075.04 | 2 | 12.83 | 2023 | 52 | 0.48 / 617.88 | 5 | 47 |
3 | 7 | 1108.28 | 80 | 11.94 | 2002 | 1912 | 2.39 / 619.79 | 47 | 64 |
4 | 13 | 45.08 | 20 | 14.23 | 400 | 114 | 2.50 / 619.91 | 5 | 79 |
5 | 8 | -0.28 | 228 | 14.14 | 319 | 1028 | 3.53 / 620.94 | 5 | 137 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 61 | 14.21 | 462 | 400 | 0.40 / 614.41 | 5 | 12 |
2 | 7 | 1063.96 | 81 | 12.01 | 1921 | 1869 | 2.27 / 616.28 | 5 | 66 |
3 | 13 | 35.56 | 20 | 14.24 | 385 | 110 | 2.38 / 616.39 | 5 | 78 |
4 | 8 | -0.16 | 225 | 14.16 | 318 | 1013 | 3.39 / 617.41 | 5 | 131 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 61 | 14.24 | 464 | 403 | 0.40 / 611.05 | 5 | 10 |
2 | 7 | 1059.08 | 80 | 12.12 | 1885 | 1828 | 2.23 / 612.87 | 5 | 64 |
3 | 13 | 68.96 | 20 | 14.20 | 440 | 125 | 2.36 / 613.00 | 5 | 82 |
4 | 8 | -0.32 | 228 | 14.18 | 314 | 1015 | 3.37 / 614.01 | 5 | 140 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 64 | 14.19 | 466 | 423 | 0.42 / 603.16 | 5 | 12 |
2 | 3 | 886.36 | -2 | 14.19 | 466 | 0 | 0.00 / 603.16 | 5 | 12 |
3 | 7 | 2026.64 | 80 | 11.03 | 3368 | 2972 | 3.40 / 606.13 | 12 | 28 |
4 | 13 | 2000.08 | 20 | 12.41 | 3349 | 831 | 4.23 / 606.96 | 5 | 46 |
5 | 13 | 1927.76 | 20 | 12.57 | 3229 | 812 | 5.04 / 607.77 | 5 | 50 |
6 | 13 | 1831.24 | 20 | 12.64 | 3111 | 786 | 5.82 / 608.56 | 5 | 55 |
7 | 13 | 1197.64 | 20 | 13.10 | 2184 | 572 | 6.40 / 609.13 | 5 | 76 |
8 | 13 | 545.32 | 20 | 13.63 | 1201 | 327 | 6.72 / 609.46 | 5 | 91 |
9 | 13 | 97.04 | 20 | 14.15 | 497 | 141 | 6.86 / 609.60 | 5 | 84 |
10 | 8 | -0.16 | 230 | 14.18 | 320 | 1044 | 7.91 / 610.64 | 5 | 132 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 61 | 14.21 | 467 | 405 | 0.40 / 599.79 | 5 | 13 |
2 | 7 | 1053.28 | 80 | 12.10 | 1901 | 1840 | 2.24 / 601.63 | 13 | 66 |
3 | 13 | 31.52 | 20 | 14.25 | 369 | 105 | 2.35 / 601.74 | 5 | 79 |
4 | 8 | -0.20 | 225 | 14.15 | 313 | 997 | 3.35 / 602.73 | 5 | 144 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 61 | 14.24 | 459 | 399 | 0.40 / 596.44 | 5 | 14 |
2 | 7 | 1044.64 | 81 | 12.10 | 1895 | 1857 | 2.26 / 598.30 | 14 | 67 |
3 | 8 | -0.20 | 244 | 14.15 | 315 | 1088 | 3.34 / 599.39 | 5 | 131 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 61 | 14.22 | 473 | 410 | 0.41 / 593.09 | 5 | 13 |
2 | 7 | 1052.92 | 81 | 12.13 | 1898 | 1865 | 2.28 / 594.95 | 13 | 67 |
3 | 13 | 25.60 | 20 | 14.29 | 356 | 102 | 2.38 / 595.05 | 5 | 79 |
4 | 8 | -0.16 | 225 | 14.17 | 311 | 992 | 3.37 / 596.04 | 5 | 149 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.12 | 60 | 14.18 | 490 | 417 | 0.42 / 585.11 | 5 | 13 |
2 | 10 | 1009.08 | 3 | 13.20 | 1909 | 76 | 0.49 / 585.18 | 5 | 51 |
3 | 3 | 1024.76 | 1 | 12.63 | 1956 | 25 | 0.52 / 585.21 | 5 | 5 |
4 | 7 | 2008.48 | 80 | 11.11 | 3335 | 2964 | 3.48 / 588.17 | 5 | 30 |
5 | 13 | 1989.24 | 20 | 12.46 | 3328 | 829 | 4.31 / 589.00 | 5 | 47 |
6 | 13 | 1920.00 | 20 | 12.57 | 3238 | 814 | 5.12 / 589.82 | 5 | 51 |
7 | 13 | 1822.28 | 20 | 12.67 | 3095 | 784 | 5.91 / 590.60 | 5 | 56 |
8 | 13 | 1253.92 | 20 | 13.08 | 2256 | 590 | 6.50 / 591.19 | 5 | 74 |
9 | 13 | 585.20 | 20 | 13.58 | 1258 | 342 | 6.84 / 591.53 | 5 | 90 |
10 | 13 | 69.64 | 20 | 14.23 | 435 | 124 | 6.96 / 591.66 | 5 | 79 |
11 | 8 | -0.08 | 228 | 14.19 | 315 | 1019 | 7.98 / 592.68 | 5 | 132 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 61 | 14.20 | 462 | 400 | 0.40 / 581.71 | 5 | 12 |
2 | 7 | 1055.76 | 80 | 12.12 | 1932 | 1873 | 2.27 / 583.58 | 12 | 65 |
3 | 13 | 29.24 | 20 | 14.26 | 372 | 106 | 2.38 / 583.69 | 5 | 79 |
4 | 8 | -0.08 | 223 | 14.16 | 318 | 1004 | 3.38 / 584.69 | 5 | 144 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 61 | 14.21 | 479 | 415 | 0.42 / 578.30 | 5 | 12 |
2 | 7 | 1074.60 | 80 | 12.11 | 1946 | 1885 | 2.30 / 580.18 | 5 | 66 |
3 | 13 | 38.56 | 20 | 14.26 | 392 | 112 | 2.41 / 580.30 | 5 | 80 |
4 | 8 | -0.24 | 225 | 14.16 | 318 | 1013 | 3.43 / 581.31 | 5 | 135 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 61 | 14.23 | 453 | 393 | 0.39 / 574.80 | 5 | 10 |
2 | 7 | 1080.12 | 80 | 12.11 | 1968 | 1907 | 2.30 / 576.70 | 5 | 65 |
3 | 13 | 70.64 | 20 | 14.20 | 463 | 131 | 2.43 / 576.83 | 5 | 84 |
4 | 8 | -0.24 | 225 | 14.16 | 329 | 1048 | 3.48 / 577.88 | 5 | 130 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 60 | 14.22 | 468 | 399 | 0.40 / 567.01 | 5 | 12 |
2 | 7 | 2006.32 | 80 | 11.22 | 3335 | 2993 | 3.39 / 570.00 | 5 | 31 |
3 | 13 | 1976.12 | 20 | 12.50 | 3313 | 828 | 4.22 / 570.83 | 5 | 48 |
4 | 13 | 1896.84 | 20 | 12.59 | 3226 | 812 | 5.03 / 571.65 | 5 | 52 |
5 | 13 | 1699.24 | 20 | 12.82 | 2878 | 738 | 5.77 / 572.38 | 5 | 59 |
6 | 13 | 1154.60 | 20 | 13.16 | 2099 | 552 | 6.32 / 572.94 | 5 | 78 |
7 | 13 | 492.20 | 20 | 13.68 | 1122 | 307 | 6.63 / 573.24 | 5 | 91 |
8 | 13 | 69.96 | 20 | 14.19 | 449 | 127 | 6.76 / 573.37 | 5 | 85 |
9 | 8 | -0.32 | 230 | 14.17 | 317 | 1033 | 7.79 / 574.40 | 5 | 146 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 61 | 14.23 | 459 | 398 | 0.40 / 563.61 | 5 | 13 |
2 | 7 | 1051.08 | 80 | 12.16 | 1916 | 1864 | 2.26 / 565.48 | 13 | 67 |
3 | 13 | 54.64 | 20 | 14.23 | 420 | 120 | 2.38 / 565.59 | 5 | 84 |
4 | 8 | -0.16 | 225 | 14.17 | 319 | 1017 | 3.40 / 566.61 | 5 | 144 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 61 | 14.20 | 471 | 408 | 0.41 / 560.19 | 5 | 13 |
2 | 7 | 1062.72 | 81 | 12.13 | 1941 | 1907 | 2.32 / 562.09 | 13 | 66 |
3 | 13 | 12.24 | 20 | 14.31 | 342 | 98 | 2.41 / 562.19 | 5 | 81 |
4 | 8 | -0.16 | 226 | 14.12 | 320 | 1021 | 3.43 / 563.21 | 5 | 139 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 60 | 14.22 | 473 | 404 | 0.40 / 556.64 | 5 | 11 |
2 | 3 | 1031.24 | 1 | 12.00 | 1979 | 24 | 0.43 / 556.67 | 5 | 5 |
3 | 7 | 1091.08 | 81 | 12.13 | 1938 | 1904 | 2.33 / 558.57 | 5 | 63 |
4 | 13 | 40.16 | 20 | 14.24 | 414 | 118 | 2.45 / 558.69 | 5 | 83 |
5 | 8 | -0.32 | 231 | 14.13 | 334 | 1090 | 3.54 / 559.78 | 5 | 140 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 60 | 14.23 | 452 | 386 | 0.39 / 548.88 | 5 | 13 |
2 | 7 | 2008.04 | 81 | 11.23 | 3336 | 3035 | 3.42 / 551.91 | 5 | 31 |
3 | 13 | 1975.00 | 20 | 12.51 | 3296 | 825 | 4.25 / 552.74 | 5 | 48 |
4 | 13 | 1895.60 | 20 | 12.61 | 3190 | 805 | 5.05 / 553.54 | 5 | 53 |
5 | 13 | 1593.72 | 20 | 12.88 | 2722 | 701 | 5.75 / 554.24 | 5 | 62 |
6 | 13 | 1049.44 | 20 | 13.25 | 1932 | 512 | 6.26 / 554.76 | 5 | 80 |
7 | 13 | 496.80 | 20 | 13.69 | 1121 | 307 | 6.57 / 555.06 | 5 | 89 |
8 | 13 | 67.60 | 20 | 14.21 | 451 | 128 | 6.70 / 555.19 | 5 | 84 |
9 | 8 | -0.20 | 232 | 14.17 | 319 | 1049 | 7.75 / 556.24 | 5 | 130 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 61 | 14.21 | 454 | 394 | 0.39 / 545.58 | 5 | 14 |
2 | 7 | 1040.28 | 80 | 12.22 | 1845 | 1804 | 2.20 / 547.39 | 14 | 65 |
3 | 13 | 56.64 | 20 | 14.20 | 420 | 119 | 2.32 / 547.51 | 5 | 87 |
4 | 8 | -0.20 | 232 | 14.18 | 300 | 987 | 3.30 / 548.49 | 5 | 130 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 61 | 14.21 | 470 | 407 | 0.41 / 542.25 | 5 | 14 |
2 | 7 | 1064.44 | 80 | 12.20 | 1877 | 1832 | 2.24 / 544.09 | 14 | 64 |
3 | 13 | 62.00 | 20 | 14.21 | 421 | 120 | 2.36 / 544.21 | 5 | 88 |
4 | 8 | -0.28 | 232 | 14.18 | 299 | 984 | 3.34 / 545.19 | 5 | 129 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 62 | 14.25 | 455 | 402 | 0.40 / 538.82 | 5 | 11 |
2 | 3 | 950.68 | -1 | 14.25 | 455 | 0 | 0.00 / 538.82 | 5 | 11 |
3 | 7 | 1072.88 | 81 | 12.18 | 1889 | 1864 | 2.27 / 540.68 | 11 | 64 |
4 | 13 | 67.36 | 20 | 14.21 | 445 | 126 | 2.39 / 540.81 | 5 | 88 |
5 | 13 | 16.76 | 20 | 14.28 | 350 | 100 | 2.49 / 540.91 | 5 | 82 |
6 | 8 | -0.20 | 216 | 14.11 | 308 | 939 | 3.43 / 541.85 | 5 | 135 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 61 | 14.22 | 468 | 406 | 0.41 / 530.96 | 5 | 13 |
2 | 3 | 967.36 | -1 | 14.22 | 468 | 0 | 0.00 / 530.96 | 5 | 13 |
3 | 7 | 2028.08 | 80 | 11.27 | 3376 | 3044 | 3.45 / 534.01 | 13 | 31 |
4 | 13 | 1995.56 | 20 | 12.51 | 3356 | 840 | 4.29 / 534.85 | 5 | 48 |
5 | 13 | 1911.88 | 20 | 12.62 | 3231 | 816 | 5.10 / 535.66 | 5 | 52 |
6 | 13 | 1714.80 | 20 | 12.85 | 2886 | 742 | 5.85 / 536.40 | 5 | 59 |
7 | 13 | 1063.28 | 20 | 13.25 | 1962 | 520 | 6.37 / 536.92 | 5 | 79 |
8 | 13 | 521.48 | 20 | 13.70 | 1118 | 306 | 6.67 / 537.23 | 5 | 83 |
9 | 13 | 83.08 | 20 | 14.18 | 471 | 134 | 6.81 / 537.36 | 5 | 89 |
10 | 8 | -0.28 | 242 | 14.17 | 307 | 1053 | 7.86 / 538.42 | 5 | 133 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 61 | 14.22 | 463 | 402 | 0.40 / 527.54 | 5 | 13 |
2 | 7 | 1057.64 | 80 | 12.20 | 1911 | 1865 | 2.27 / 529.40 | 13 | 68 |
3 | 13 | 60.04 | 20 | 14.20 | 431 | 122 | 2.39 / 529.53 | 5 | 88 |
4 | 8 | -0.12 | 232 | 14.16 | 314 | 1032 | 3.42 / 530.56 | 5 | 133 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 61 | 14.27 | 450 | 392 | 0.39 / 524.19 | 5 | 12 |
2 | 7 | 1053.52 | 80 | 12.23 | 1860 | 1820 | 2.21 / 526.00 | 12 | 65 |
3 | 13 | 61.28 | 20 | 14.22 | 429 | 122 | 2.33 / 526.13 | 5 | 88 |
4 | 8 | -0.28 | 232 | 14.17 | 307 | 1009 | 3.34 / 527.14 | 5 | 132 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 62 | 14.25 | 442 | 391 | 0.39 / 520.92 | 5 | 10 |
2 | 7 | 1033.52 | 80 | 12.23 | 1819 | 1780 | 2.17 / 522.70 | 10 | 65 |
3 | 13 | 54.44 | 20 | 14.25 | 407 | 116 | 2.29 / 522.81 | 5 | 87 |
4 | 8 | -0.28 | 232 | 14.20 | 297 | 978 | 3.26 / 523.79 | 5 | 136 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 61 | 14.24 | 456 | 396 | 0.40 / 513.27 | 5 | 11 |
2 | 7 | 2029.88 | 81 | 11.32 | 3361 | 3082 | 3.48 / 516.36 | 11 | 32 |
3 | 13 | 1995.68 | 20 | 12.53 | 3330 | 834 | 4.31 / 517.19 | 5 | 49 |
4 | 13 | 1914.88 | 20 | 12.67 | 3215 | 815 | 5.13 / 518.01 | 5 | 53 |
5 | 13 | 1609.72 | 20 | 12.95 | 2692 | 697 | 5.82 / 518.70 | 5 | 60 |
6 | 13 | 968.72 | 20 | 13.34 | 1776 | 474 | 6.30 / 519.18 | 5 | 79 |
7 | 13 | 431.28 | 20 | 13.79 | 976 | 269 | 6.57 / 519.45 | 5 | 85 |
8 | 13 | 48.44 | 20 | 14.26 | 391 | 112 | 6.68 / 519.56 | 5 | 85 |
9 | 8 | -0.12 | 232 | 14.20 | 295 | 972 | 7.65 / 520.53 | 5 | 130 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 60 | 14.27 | 453 | 388 | 0.39 / 509.87 | 5 | 11 |
2 | 7 | 1078.12 | 81 | 12.22 | 1891 | 1872 | 2.26 / 511.74 | 5 | 65 |
3 | 13 | 68.52 | 20 | 14.21 | 442 | 126 | 2.39 / 511.87 | 5 | 89 |
4 | 8 | -0.24 | 232 | 14.17 | 308 | 1013 | 3.40 / 512.88 | 5 | 136 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 62 | 14.25 | 461 | 407 | 0.41 / 506.51 | 5 | 11 |
2 | 3 | 960.72 | -1 | 14.25 | 461 | 0 | 0.00 / 506.51 | 5 | 11 |
3 | 7 | 1078.40 | 80 | 12.25 | 1879 | 1841 | 2.25 / 508.35 | 11 | 63 |
4 | 13 | 74.00 | 20 | 14.20 | 443 | 126 | 2.37 / 508.48 | 5 | 87 |
5 | 8 | -0.24 | 235 | 14.19 | 301 | 1004 | 3.38 / 509.48 | 5 | 141 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 62 | 14.25 | 451 | 398 | 0.40 / 503.16 | 5 | 9 |
2 | 7 | 1051.56 | 80 | 12.21 | 1842 | 1799 | 2.20 / 504.96 | 9 | 65 |
3 | 13 | 64.16 | 20 | 14.23 | 439 | 125 | 2.32 / 505.09 | 5 | 86 |
4 | 8 | -0.28 | 232 | 14.19 | 308 | 1014 | 3.34 / 506.10 | 5 | 130 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 61 | 14.25 | 461 | 401 | 0.40 / 495.36 | 5 | 10 |
2 | 7 | 2006.44 | 80 | 11.38 | 3334 | 3035 | 3.44 / 498.40 | 10 | 32 |
3 | 13 | 1979.68 | 20 | 12.56 | 3310 | 831 | 4.27 / 499.23 | 5 | 48 |
4 | 13 | 1904.60 | 20 | 12.68 | 3211 | 814 | 5.08 / 500.05 | 5 | 53 |
5 | 13 | 1811.00 | 20 | 12.78 | 3075 | 786 | 5.87 / 500.83 | 5 | 58 |
6 | 13 | 1038.24 | 20 | 13.32 | 1887 | 503 | 6.37 / 501.33 | 5 | 79 |
7 | 13 | 490.88 | 20 | 13.74 | 1084 | 298 | 6.67 / 501.63 | 5 | 84 |
8 | 13 | 66.12 | 20 | 14.25 | 432 | 123 | 6.79 / 501.76 | 5 | 84 |
9 | 8 | -0.32 | 235 | 14.19 | 303 | 1010 | 7.80 / 502.77 | 5 | 138 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 62 | 14.27 | 467 | 413 | 0.41 / 492.00 | 5 | 9 |
2 | 7 | 1041.08 | 81 | 12.25 | 1850 | 1836 | 2.25 / 493.84 | 9 | 64 |
3 | 13 | 48.92 | 20 | 14.27 | 409 | 117 | 2.37 / 493.96 | 5 | 83 |
4 | 8 | -0.24 | 230 | 14.19 | 309 | 1008 | 3.37 / 494.96 | 5 | 132 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 62 | 14.27 | 455 | 403 | 0.40 / 488.59 | 5 | 10 |
2 | 7 | 1047.28 | 81 | 12.23 | 1881 | 1863 | 2.27 / 490.46 | 10 | 68 |
3 | 13 | 51.84 | 20 | 14.27 | 416 | 119 | 2.38 / 490.57 | 5 | 83 |
4 | 8 | -0.32 | 230 | 14.20 | 311 | 1016 | 3.40 / 491.59 | 5 | 140 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 62 | 14.32 | 450 | 400 | 0.40 / 485.21 | 5 | 8 |
2 | 7 | 1057.08 | 81 | 12.18 | 1881 | 1856 | 2.26 / 487.07 | 8 | 65 |
3 | 13 | 61.40 | 20 | 14.25 | 433 | 123 | 2.38 / 487.19 | 5 | 83 |
4 | 8 | -0.36 | 230 | 14.21 | 306 | 1000 | 3.38 / 488.19 | 5 | 130 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 61 | 14.29 | 445 | 388 | 0.39 / 477.57 | 5 | 10 |
2 | 7 | 2027.84 | 80 | 11.40 | 3355 | 3060 | 3.45 / 480.63 | 10 | 33 |
3 | 13 | 1989.64 | 20 | 12.59 | 3341 | 841 | 4.29 / 481.48 | 5 | 49 |
4 | 13 | 1909.60 | 20 | 12.72 | 3203 | 815 | 5.10 / 482.29 | 5 | 53 |
5 | 13 | 1500.56 | 20 | 13.04 | 2556 | 667 | 5.77 / 482.96 | 5 | 63 |
6 | 13 | 974.12 | 20 | 13.37 | 1816 | 486 | 6.26 / 483.44 | 5 | 81 |
7 | 13 | 332.56 | 20 | 13.89 | 857 | 238 | 6.49 / 483.68 | 5 | 85 |
8 | 13 | 54.88 | 20 | 14.29 | 413 | 118 | 6.61 / 483.80 | 5 | 81 |
9 | 8 | -0.36 | 232 | 14.20 | 307 | 1011 | 7.62 / 484.81 | 5 | 141 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 62 | 14.32 | 447 | 397 | 0.40 / 474.29 | 5 | 8 |
2 | 7 | 1043.84 | 80 | 12.31 | 1835 | 1807 | 2.20 / 476.10 | 8 | 65 |
3 | 13 | 56.64 | 20 | 14.27 | 413 | 118 | 2.32 / 476.22 | 5 | 82 |
4 | 8 | -0.16 | 230 | 14.22 | 296 | 968 | 3.29 / 477.19 | 5 | 135 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 62 | 14.33 | 448 | 398 | 0.40 / 470.96 | 5 | 7 |
2 | 7 | 1045.72 | 80 | 12.28 | 1868 | 1835 | 2.23 / 472.80 | 7 | 67 |
3 | 13 | 51.72 | 20 | 14.30 | 397 | 114 | 2.35 / 472.91 | 5 | 82 |
4 | 8 | -0.36 | 231 | 14.22 | 300 | 985 | 3.33 / 473.90 | 5 | 138 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 62 | 14.33 | 459 | 408 | 0.41 / 467.61 | 5 | 7 |
2 | 7 | 1057.96 | 80 | 12.21 | 1857 | 1814 | 2.22 / 469.42 | 7 | 63 |
3 | 13 | 64.84 | 20 | 14.26 | 434 | 124 | 2.35 / 469.55 | 5 | 84 |
4 | 8 | -0.52 | 235 | 14.20 | 305 | 1018 | 3.36 / 470.56 | 5 | 147 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 61 | 14.31 | 446 | 389 | 0.39 / 459.89 | 5 | 8 |
2 | 7 | 2006.56 | 80 | 11.48 | 3333 | 3061 | 3.45 / 462.95 | 8 | 35 |
3 | 13 | 1967.44 | 20 | 12.65 | 3279 | 830 | 4.28 / 463.78 | 5 | 50 |
4 | 13 | 1886.24 | 20 | 12.76 | 3171 | 809 | 5.09 / 464.59 | 5 | 55 |
5 | 13 | 1582.80 | 20 | 13.01 | 2687 | 699 | 5.79 / 465.29 | 5 | 62 |
6 | 13 | 1042.24 | 20 | 13.35 | 1916 | 512 | 6.30 / 465.80 | 5 | 80 |
7 | 13 | 388.12 | 20 | 13.87 | 933 | 259 | 6.56 / 466.06 | 5 | 87 |
8 | 13 | 40.12 | 20 | 14.30 | 401 | 115 | 6.67 / 466.17 | 5 | 82 |
9 | 8 | -0.28 | 230 | 14.19 | 315 | 1028 | 7.70 / 467.20 | 5 | 138 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 62 | 14.32 | 448 | 398 | 0.40 / 456.59 | 5 | 8 |
2 | 7 | 1051.36 | 80 | 12.32 | 1870 | 1843 | 2.24 / 458.43 | 8 | 67 |
3 | 13 | 53.96 | 20 | 14.27 | 399 | 114 | 2.35 / 458.54 | 5 | 85 |
4 | 8 | -0.28 | 228 | 14.22 | 295 | 956 | 3.31 / 459.50 | 5 | 131 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 62 | 14.33 | 438 | 389 | 0.39 / 453.30 | 5 | 7 |
2 | 7 | 1045.68 | 80 | 12.32 | 1838 | 1812 | 2.20 / 455.11 | 7 | 64 |
3 | 13 | 53.92 | 20 | 14.27 | 404 | 115 | 2.32 / 455.23 | 5 | 84 |
4 | 8 | -0.48 | 230 | 14.23 | 294 | 962 | 3.28 / 456.19 | 5 | 136 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 62 | 14.33 | 434 | 386 | 0.39 / 449.99 | 6 | 7 |
2 | 7 | 1072.72 | 80 | 12.22 | 1901 | 1858 | 2.24 / 451.85 | 5 | 66 |
3 | 13 | 40.04 | 20 | 14.32 | 383 | 110 | 2.35 / 451.96 | 5 | 79 |
4 | 8 | -0.40 | 230 | 14.25 | 291 | 954 | 3.31 / 452.91 | 5 | 138 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 61 | 14.33 | 448 | 392 | 0.39 / 442.95 | 5 | 7 |
2 | 7 | 1817.96 | 80 | 11.63 | 3047 | 2835 | 3.23 / 445.78 | 5 | 43 |
3 | 13 | 1817.28 | 20 | 12.74 | 3083 | 786 | 4.01 / 446.57 | 5 | 55 |
4 | 13 | 1738.56 | 20 | 12.86 | 2937 | 755 | 4.77 / 447.32 | 5 | 60 |
5 | 13 | 1430.56 | 20 | 13.14 | 2432 | 639 | 5.41 / 447.96 | 5 | 67 |
6 | 13 | 890.36 | 20 | 13.48 | 1689 | 455 | 5.86 / 448.42 | 5 | 83 |
7 | 13 | 130.16 | 20 | 14.20 | 531 | 151 | 6.01 / 448.57 | 5 | 84 |
8 | 13 | 29.24 | 20 | 14.38 | 353 | 102 | 6.11 / 448.67 | 5 | 77 |
9 | 8 | -0.28 | 223 | 14.21 | 294 | 932 | 7.05 / 449.60 | 5 | 130 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 62 | 14.31 | 446 | 396 | 0.40 / 439.58 | 5 | 7 |
2 | 7 | 1080.08 | 80 | 12.34 | 1921 | 1896 | 2.29 / 441.48 | 5 | 67 |
3 | 13 | 38.04 | 20 | 14.34 | 370 | 106 | 2.40 / 441.58 | 5 | 80 |
4 | 8 | -0.40 | 230 | 14.23 | 298 | 975 | 3.37 / 442.56 | 5 | 137 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 61 | 14.36 | 444 | 389 | 0.39 / 436.22 | 5 | 7 |
2 | 7 | 1076.76 | 81 | 12.34 | 1895 | 1894 | 2.28 / 438.12 | 5 | 67 |
3 | 13 | 37.92 | 20 | 14.33 | 373 | 107 | 2.39 / 438.22 | 5 | 80 |
4 | 8 | -0.32 | 228 | 14.24 | 296 | 961 | 3.35 / 439.18 | 5 | 130 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 61 | 14.37 | 447 | 392 | 0.39 / 432.86 | 6 | 6 |
2 | 7 | 1085.32 | 80 | 12.26 | 1919 | 1882 | 2.27 / 434.74 | 5 | 67 |
3 | 13 | 42.72 | 20 | 14.32 | 379 | 109 | 2.38 / 434.85 | 5 | 82 |
4 | 13 | 21.88 | 20 | 14.28 | 344 | 98 | 2.48 / 434.95 | 5 | 80 |
5 | 8 | -0.48 | 211 | 14.21 | 296 | 887 | 3.37 / 435.83 | 5 | 139 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 61 | 14.31 | 443 | 387 | 0.39 / 425.31 | 5 | 7 |
2 | 7 | 2006.16 | 80 | 11.61 | 3333 | 3096 | 3.48 / 428.41 | 5 | 36 |
3 | 13 | 1966.04 | 20 | 12.72 | 3287 | 836 | 4.32 / 429.24 | 5 | 50 |
4 | 13 | 1882.12 | 20 | 12.83 | 3175 | 815 | 5.13 / 430.06 | 5 | 56 |
5 | 13 | 1474.36 | 20 | 13.15 | 2528 | 665 | 5.80 / 430.72 | 5 | 64 |
6 | 13 | 942.84 | 20 | 13.48 | 1742 | 470 | 6.27 / 431.19 | 5 | 80 |
7 | 13 | 197.16 | 20 | 14.11 | 646 | 182 | 6.45 / 431.37 | 5 | 86 |
8 | 13 | 44.60 | 20 | 14.32 | 397 | 114 | 6.56 / 431.49 | 5 | 83 |
9 | 8 | -0.44 | 228 | 14.22 | 301 | 976 | 7.54 / 432.46 | 5 | 141 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 61 | 14.30 | 447 | 390 | 0.39 / 421.98 | 5 | 8 |
2 | 7 | 1060.12 | 80 | 12.39 | 1890 | 1873 | 2.26 / 423.85 | 8 | 69 |
3 | 13 | 55.36 | 20 | 14.28 | 413 | 118 | 2.38 / 423.97 | 5 | 86 |
4 | 8 | -0.40 | 231 | 14.22 | 291 | 956 | 3.34 / 424.92 | 5 | 146 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 61 | 14.31 | 457 | 399 | 0.40 / 418.65 | 5 | 8 |
2 | 7 | 1061.52 | 80 | 12.40 | 1862 | 1847 | 2.25 / 420.49 | 8 | 66 |
3 | 13 | 36.00 | 20 | 14.30 | 377 | 108 | 2.35 / 420.60 | 5 | 85 |
4 | 8 | 0.00 | 230 | 14.17 | 303 | 988 | 3.34 / 421.59 | 5 | 133 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 61 | 14.35 | 443 | 388 | 0.39 / 415.24 | 5 | 7 |
2 | 7 | 1071.88 | 80 | 12.36 | 1884 | 1863 | 2.25 / 417.10 | 5 | 65 |
3 | 13 | 38.88 | 20 | 14.30 | 393 | 112 | 2.36 / 417.22 | 5 | 85 |
4 | 13 | 20.00 | 20 | 14.25 | 360 | 103 | 2.47 / 417.32 | 5 | 84 |
5 | 8 | -0.52 | 211 | 14.19 | 310 | 928 | 3.39 / 418.25 | 5 | 136 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 61 | 14.32 | 444 | 388 | 0.39 / 407.62 | 5 | 8 |
2 | 7 | 2007.84 | 80 | 11.66 | 3332 | 3108 | 3.50 / 410.73 | 8 | 37 |
3 | 13 | 1966.76 | 20 | 12.75 | 3295 | 840 | 4.34 / 411.57 | 5 | 51 |
4 | 13 | 1881.32 | 20 | 12.88 | 3145 | 810 | 5.15 / 412.38 | 5 | 55 |
5 | 13 | 1571.40 | 20 | 13.14 | 2666 | 701 | 5.85 / 413.08 | 5 | 63 |
6 | 13 | 922.68 | 20 | 13.53 | 1709 | 462 | 6.31 / 413.54 | 5 | 80 |
7 | 13 | 275.56 | 20 | 14.02 | 770 | 216 | 6.53 / 413.76 | 5 | 88 |
8 | 13 | 36.64 | 20 | 14.34 | 385 | 110 | 6.64 / 413.87 | 5 | 85 |
9 | 8 | -0.40 | 228 | 14.22 | 304 | 986 | 7.62 / 414.85 | 5 | 130 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 61 | 14.33 | 440 | 385 | 0.38 / 404.27 | 5 | 8 |
2 | 7 | 1048.00 | 81 | 12.47 | 1841 | 1860 | 2.24 / 406.13 | 8 | 70 |
3 | 13 | 48.16 | 20 | 14.31 | 398 | 114 | 2.36 / 406.24 | 5 | 88 |
4 | 8 | -0.36 | 230 | 14.20 | 303 | 990 | 3.35 / 407.23 | 5 | 146 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 61 | 14.32 | 451 | 394 | 0.39 / 400.90 | 5 | 8 |
2 | 7 | 1072.00 | 81 | 12.47 | 1863 | 1882 | 2.28 / 402.78 | 5 | 67 |
3 | 13 | 36.16 | 20 | 14.30 | 388 | 111 | 2.39 / 402.89 | 5 | 87 |
4 | 8 | -0.44 | 230 | 14.17 | 305 | 994 | 3.38 / 403.88 | 5 | 142 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 61 | 14.36 | 437 | 383 | 0.38 / 397.54 | 5 | 7 |
2 | 7 | 1072.16 | 81 | 12.47 | 1862 | 1881 | 2.26 / 399.42 | 5 | 68 |
3 | 13 | 35.52 | 20 | 14.32 | 384 | 110 | 2.37 / 399.53 | 5 | 85 |
4 | 8 | -0.60 | 228 | 14.19 | 300 | 971 | 3.34 / 400.50 | 5 | 131 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 61 | 14.36 | 442 | 387 | 0.39 / 390.21 | 5 | 7 |
2 | 7 | 1861.44 | 80 | 11.82 | 3111 | 2942 | 3.33 / 393.15 | 5 | 45 |
3 | 13 | 1860.64 | 20 | 12.85 | 3113 | 800 | 4.13 / 393.95 | 5 | 56 |
4 | 13 | 1860.68 | 20 | 12.91 | 3140 | 811 | 4.94 / 394.76 | 5 | 58 |
5 | 13 | 1794.24 | 20 | 13.00 | 3021 | 785 | 5.73 / 395.54 | 5 | 63 |
6 | 13 | 778.80 | 20 | 13.66 | 1468 | 401 | 6.13 / 395.95 | 5 | 83 |
7 | 13 | 134.60 | 20 | 14.20 | 551 | 156 | 6.28 / 396.10 | 5 | 90 |
8 | 13 | 32.96 | 20 | 14.36 | 372 | 107 | 6.39 / 396.21 | 5 | 84 |
9 | 8 | -0.44 | 220 | 14.20 | 304 | 950 | 7.34 / 397.16 | 5 | 131 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 61 | 14.35 | 455 | 398 | 0.40 / 386.84 | 5 | 7 |
2 | 7 | 1071.00 | 80 | 12.49 | 1906 | 1904 | 2.30 / 388.75 | 5 | 70 |
3 | 13 | 55.64 | 20 | 14.30 | 413 | 118 | 2.42 / 388.87 | 5 | 88 |
4 | 8 | -0.44 | 228 | 14.22 | 294 | 953 | 3.37 / 389.82 | 5 | 130 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 61 | 14.37 | 445 | 390 | 0.39 / 383.37 | 5 | 7 |
2 | 3 | 1021.24 | 1 | 12.54 | 1943 | 24 | 0.41 / 383.39 | 5 | 5 |
3 | 7 | 1083.08 | 80 | 12.52 | 1901 | 1904 | 2.32 / 385.30 | 5 | 67 |
4 | 13 | 40.48 | 20 | 14.33 | 395 | 113 | 2.43 / 385.41 | 5 | 85 |
5 | 13 | 20.36 | 20 | 14.28 | 360 | 103 | 2.53 / 385.51 | 5 | 83 |
6 | 8 | -0.36 | 211 | 14.20 | 311 | 932 | 3.47 / 386.45 | 5 | 146 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 61 | 14.40 | 428 | 376 | 0.38 / 379.99 | 6 | 6 |
2 | 7 | 1084.68 | 80 | 12.57 | 1881 | 1892 | 2.27 / 381.88 | 5 | 68 |
3 | 13 | 39.12 | 20 | 14.33 | 393 | 113 | 2.38 / 381.99 | 5 | 86 |
4 | 8 | -0.52 | 230 | 14.23 | 302 | 988 | 3.37 / 382.98 | 5 | 139 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 61 | 14.33 | 449 | 392 | 0.39 / 372.46 | 5 | 8 |
2 | 7 | 2029.28 | 80 | 11.81 | 3356 | 3171 | 3.56 / 375.63 | 8 | 39 |
3 | 13 | 1980.32 | 20 | 12.86 | 3289 | 846 | 4.41 / 376.48 | 5 | 52 |
4 | 13 | 1892.68 | 20 | 12.97 | 3157 | 819 | 5.23 / 377.30 | 5 | 58 |
5 | 13 | 1475.88 | 20 | 13.26 | 2512 | 666 | 5.89 / 377.96 | 5 | 68 |
6 | 13 | 830.40 | 20 | 13.67 | 1539 | 421 | 6.32 / 378.38 | 5 | 83 |
7 | 13 | 184.20 | 20 | 14.17 | 609 | 173 | 6.49 / 378.55 | 5 | 87 |
8 | 13 | 40.08 | 20 | 14.36 | 383 | 110 | 6.60 / 378.66 | 5 | 86 |
9 | 8 | -0.40 | 225 | 14.25 | 295 | 946 | 7.54 / 379.61 | 5 | 137 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 61 | 14.32 | 452 | 395 | 0.39 / 369.08 | 5 | 8 |
2 | 7 | 1065.88 | 80 | 12.57 | 1879 | 1890 | 2.28 / 370.96 | 8 | 69 |
3 | 13 | 31.92 | 20 | 14.33 | 373 | 107 | 2.39 / 371.07 | 5 | 87 |
4 | 8 | -0.36 | 230 | 14.19 | 305 | 995 | 3.39 / 372.07 | 5 | 138 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 61 | 14.32 | 434 | 379 | 0.38 / 365.73 | 5 | 9 |
2 | 7 | 1054.60 | 80 | 12.62 | 1839 | 1857 | 2.24 / 367.58 | 9 | 70 |
3 | 13 | 44.36 | 20 | 14.30 | 401 | 115 | 2.35 / 367.70 | 5 | 90 |
4 | 8 | -0.44 | 225 | 14.22 | 307 | 982 | 3.33 / 368.68 | 5 | 129 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 61 | 14.38 | 432 | 379 | 0.38 / 362.38 | 5 | 7 |
2 | 7 | 1063.72 | 81 | 12.64 | 1860 | 1904 | 2.28 / 364.29 | 7 | 69 |
3 | 13 | 50.36 | 20 | 14.34 | 394 | 113 | 2.40 / 364.40 | 5 | 90 |
4 | 8 | -0.44 | 228 | 14.24 | 292 | 948 | 3.34 / 365.35 | 5 | 133 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 61 | 14.34 | 450 | 394 | 0.39 / 357.20 | 5 | 9 |
2 | 7 | 1194.12 | 80 | 12.54 | 2055 | 2062 | 2.46 / 359.26 | 9 | 61 |
3 | 13 | 1193.92 | 20 | 13.29 | 2112 | 561 | 3.02 / 359.82 | 5 | 75 |
4 | 13 | 1127.64 | 20 | 13.43 | 1998 | 537 | 3.55 / 360.36 | 5 | 78 |
5 | 13 | 822.96 | 20 | 13.68 | 1552 | 425 | 3.98 / 360.79 | 5 | 81 |
6 | 13 | 170.32 | 20 | 14.23 | 581 | 165 | 4.14 / 360.95 | 5 | 88 |
7 | 13 | 35.28 | 20 | 14.39 | 369 | 106 | 4.25 / 361.06 | 5 | 88 |
8 | 8 | -0.28 | 225 | 14.21 | 296 | 946 | 5.20 / 362.00 | 5 | 132 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 61 | 14.35 | 447 | 391 | 0.39 / 353.80 | 5 | 9 |
2 | 7 | 1057.72 | 80 | 12.66 | 1878 | 1902 | 2.29 / 355.70 | 9 | 71 |
3 | 13 | 29.96 | 20 | 14.36 | 370 | 106 | 2.40 / 355.81 | 5 | 86 |
4 | 8 | -0.32 | 231 | 14.20 | 304 | 997 | 3.40 / 356.81 | 5 | 140 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 61 | 14.35 | 449 | 393 | 0.39 / 350.41 | 5 | 8 |
2 | 7 | 1071.44 | 80 | 12.70 | 1889 | 1919 | 2.31 / 352.33 | 5 | 70 |
3 | 13 | 31.72 | 20 | 14.37 | 373 | 107 | 2.42 / 352.44 | 5 | 87 |
4 | 8 | -0.32 | 228 | 14.22 | 299 | 969 | 3.39 / 353.41 | 5 | 133 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 61 | 14.36 | 432 | 378 | 0.38 / 347.03 | 5 | 8 |
2 | 7 | 1067.92 | 80 | 12.74 | 1868 | 1904 | 2.28 / 348.93 | 8 | 71 |
3 | 13 | 29.92 | 20 | 14.37 | 367 | 105 | 2.39 / 349.04 | 5 | 87 |
4 | 8 | -0.40 | 230 | 14.22 | 301 | 984 | 3.37 / 350.02 | 5 | 136 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 60 | 14.38 | 436 | 376 | 0.38 / 341.03 | 5 | 8 |
2 | 3 | 1024.36 | 1 | 13.16 | 1942 | 26 | 0.40 / 341.05 | 5 | 5 |
3 | 7 | 1479.28 | 80 | 12.46 | 2417 | 2409 | 2.81 / 343.46 | 5 | 51 |
4 | 13 | 1437.00 | 20 | 13.23 | 2489 | 659 | 3.47 / 344.12 | 5 | 70 |
5 | 13 | 1366.00 | 20 | 13.35 | 2386 | 637 | 4.11 / 344.76 | 5 | 73 |
6 | 13 | 1069.36 | 20 | 13.58 | 1915 | 520 | 4.63 / 345.28 | 5 | 79 |
7 | 13 | 418.44 | 20 | 14.02 | 961 | 269 | 4.90 / 345.55 | 5 | 87 |
8 | 13 | 45.32 | 20 | 14.39 | 393 | 113 | 5.01 / 345.66 | 5 | 88 |
9 | 8 | -0.36 | 232 | 14.26 | 299 | 989 | 6.00 / 346.65 | 5 | 140 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 61 | 14.37 | 439 | 385 | 0.38 / 337.72 | 5 | 9 |
2 | 7 | 1054.76 | 80 | 12.81 | 1825 | 1870 | 2.26 / 339.59 | 9 | 70 |
3 | 13 | 42.16 | 20 | 14.37 | 382 | 110 | 2.36 / 339.70 | 5 | 88 |
4 | 8 | -0.36 | 228 | 14.26 | 292 | 949 | 3.31 / 340.65 | 5 | 143 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 60 | 14.36 | 439 | 378 | 0.38 / 334.32 | 5 | 9 |
2 | 7 | 1074.08 | 81 | 12.79 | 1893 | 1961 | 2.34 / 336.28 | 5 | 71 |
3 | 13 | 25.24 | 20 | 14.40 | 359 | 103 | 2.44 / 336.39 | 5 | 85 |
4 | 8 | -0.24 | 225 | 14.24 | 297 | 952 | 3.39 / 337.34 | 5 | 137 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 60 | 14.39 | 445 | 384 | 0.38 / 330.85 | 5 | 8 |
2 | 3 | 1023.40 | 1 | 13.23 | 1944 | 26 | 0.41 / 330.88 | 5 | 5 |
3 | 7 | 1084.56 | 81 | 12.80 | 1925 | 1996 | 2.41 / 332.87 | 5 | 73 |
4 | 13 | 27.92 | 20 | 14.42 | 350 | 101 | 2.51 / 332.98 | 5 | 84 |
5 | 8 | -0.40 | 230 | 14.25 | 295 | 967 | 3.47 / 333.94 | 5 | 142 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 62 | 14.34 | 457 | 406 | 0.41 / 324.47 | 5 | 9 |
2 | 3 | 953.92 | -1 | 14.34 | 457 | 0 | 0.00 / 324.47 | 5 | 9 |
3 | 7 | 1620.60 | 80 | 12.43 | 2629 | 2614 | 3.02 / 327.08 | 9 | 49 |
4 | 13 | 1620.28 | 20 | 13.18 | 2770 | 730 | 3.75 / 327.81 | 5 | 65 |
5 | 13 | 1537.56 | 20 | 13.29 | 2626 | 698 | 4.45 / 328.51 | 5 | 69 |
6 | 13 | 1029.56 | 20 | 13.63 | 1876 | 511 | 4.96 / 329.02 | 5 | 82 |
7 | 13 | 500.64 | 20 | 13.98 | 1071 | 299 | 5.26 / 329.32 | 5 | 87 |
8 | 13 | 73.32 | 20 | 14.37 | 446 | 128 | 5.39 / 329.45 | 5 | 88 |
9 | 13 | 16.00 | 20 | 14.43 | 342 | 99 | 5.49 / 329.55 | 5 | 83 |
10 | 8 | -0.44 | 214 | 14.23 | 302 | 920 | 6.41 / 330.47 | 5 | 132 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 60 | 14.38 | 436 | 376 | 0.38 / 320.96 | 5 | 9 |
2 | 7 | 1072.76 | 81 | 12.82 | 1900 | 1973 | 2.35 / 322.94 | 5 | 70 |
3 | 13 | 27.28 | 20 | 14.41 | 382 | 110 | 2.46 / 323.05 | 5 | 87 |
4 | 8 | -0.36 | 228 | 14.22 | 313 | 1015 | 3.47 / 324.06 | 5 | 131 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 62 | 14.36 | 434 | 386 | 0.39 / 317.65 | 5 | 10 |
2 | 3 | 934.92 | -1 | 14.36 | 434 | 0 | 0.00 / 317.65 | 5 | 10 |
3 | 7 | 1046.32 | 80 | 12.86 | 1832 | 1885 | 2.27 / 319.53 | 10 | 73 |
4 | 13 | 23.84 | 20 | 14.41 | 346 | 100 | 2.37 / 319.63 | 5 | 87 |
5 | 8 | -0.36 | 228 | 14.25 | 294 | 955 | 3.33 / 320.59 | 5 | 138 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 60 | 14.42 | 434 | 375 | 0.38 / 314.21 | 5 | 9 |
2 | 3 | 1020.68 | 1 | 13.20 | 1935 | 26 | 0.40 / 314.23 | 5 | 5 |
3 | 7 | 1088.44 | 81 | 12.84 | 1889 | 1965 | 2.37 / 316.20 | 5 | 72 |
4 | 13 | 30.60 | 20 | 14.41 | 358 | 103 | 2.47 / 316.30 | 5 | 88 |
5 | 8 | -0.40 | 228 | 14.24 | 296 | 961 | 3.43 / 317.26 | 5 | 132 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 61 | 14.34 | 473 | 414 | 0.41 / 308.75 | 5 | 11 |
2 | 3 | 1026.52 | 1 | 13.32 | 1952 | 26 | 0.44 / 308.78 | 5 | 5 |
3 | 7 | 1295.20 | 81 | 12.62 | 2188 | 2237 | 2.68 / 311.01 | 5 | 60 |
4 | 13 | 1294.96 | 20 | 13.34 | 2271 | 606 | 3.28 / 311.62 | 5 | 76 |
5 | 13 | 1294.80 | 20 | 13.41 | 2248 | 603 | 3.89 / 312.22 | 5 | 77 |
6 | 13 | 879.72 | 20 | 13.74 | 1626 | 447 | 4.33 / 312.67 | 5 | 85 |
7 | 13 | 122.52 | 20 | 14.33 | 519 | 149 | 4.48 / 312.82 | 5 | 92 |
8 | 13 | 27.52 | 20 | 14.44 | 347 | 100 | 4.58 / 312.92 | 5 | 88 |
9 | 8 | -0.28 | 223 | 14.27 | 288 | 916 | 5.50 / 313.83 | 5 | 139 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 60 | 14.33 | 470 | 404 | 0.40 / 305.23 | 5 | 11 |
2 | 3 | 1074.48 | 2 | 13.68 | 2012 | 55 | 0.46 / 305.28 | 5 | 24 |
3 | 7 | 1095.20 | 80 | 12.83 | 1894 | 1944 | 2.40 / 307.23 | 24 | 72 |
4 | 13 | 31.56 | 20 | 14.40 | 384 | 111 | 2.51 / 307.34 | 5 | 91 |
5 | 8 | -0.28 | 230 | 14.22 | 305 | 998 | 3.51 / 308.34 | 5 | 130 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 62 | 14.33 | 439 | 390 | 0.39 / 301.89 | 5 | 13 |
2 | 3 | 910.60 | -1 | 14.33 | 439 | 0 | 0.00 / 301.89 | 5 | 13 |
3 | 7 | 1025.88 | 80 | 12.92 | 1790 | 1850 | 2.24 / 303.74 | 13 | 73 |
4 | 13 | 36.04 | 20 | 14.39 | 379 | 109 | 2.35 / 303.85 | 5 | 92 |
5 | 8 | -0.40 | 230 | 14.23 | 298 | 975 | 3.32 / 304.82 | 5 | 133 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 61 | 14.41 | 434 | 381 | 0.38 / 298.57 | 5 | 12 |
2 | 3 | 926.00 | -1 | 14.41 | 434 | 0 | 0.00 / 298.57 | 5 | 12 |
3 | 7 | 1041.96 | 81 | 12.90 | 1818 | 1900 | 2.28 / 300.47 | 12 | 73 |
4 | 13 | 36.52 | 20 | 14.40 | 362 | 104 | 2.39 / 300.58 | 5 | 93 |
5 | 8 | -0.64 | 225 | 14.24 | 288 | 923 | 3.31 / 301.50 | 5 | 132 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 59 | 14.38 | 464 | 394 | 0.39 / 292.63 | 5 | 10 |
2 | 3 | 1083.96 | 2 | 13.75 | 2027 | 56 | 0.45 / 292.69 | 5 | 33 |
3 | 7 | 1440.36 | 80 | 12.51 | 2391 | 2393 | 2.84 / 295.08 | 33 | 56 |
4 | 13 | 1439.68 | 20 | 13.25 | 2498 | 662 | 3.50 / 295.74 | 5 | 71 |
5 | 13 | 1366.32 | 20 | 13.39 | 2361 | 632 | 4.14 / 296.38 | 5 | 74 |
6 | 13 | 951.92 | 20 | 13.71 | 1716 | 471 | 4.61 / 296.85 | 5 | 81 |
7 | 13 | 405.80 | 20 | 14.08 | 939 | 264 | 4.87 / 297.11 | 5 | 91 |
8 | 13 | 37.88 | 20 | 14.45 | 379 | 110 | 4.98 / 297.22 | 5 | 92 |
9 | 8 | -0.36 | 230 | 14.26 | 296 | 971 | 5.95 / 298.19 | 5 | 131 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.88 | 61 | 14.34 | 467 | 409 | 0.41 / 289.20 | 5 | 12 |
2 | 7 | 1071.72 | 81 | 12.88 | 1894 | 1976 | 2.38 / 291.17 | 5 | 74 |
3 | 13 | 22.52 | 20 | 14.42 | 357 | 103 | 2.49 / 291.28 | 5 | 93 |
4 | 8 | -0.32 | 228 | 14.24 | 297 | 964 | 3.45 / 292.24 | 5 | 143 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 60 | 14.35 | 468 | 403 | 0.40 / 285.70 | 5 | 13 |
2 | 3 | 1042.00 | 1 | 13.66 | 1975 | 27 | 0.43 / 285.73 | 5 | 7 |
3 | 7 | 1084.44 | 81 | 12.89 | 1901 | 1985 | 2.41 / 287.71 | 7 | 74 |
4 | 13 | 27.04 | 20 | 14.42 | 364 | 105 | 2.52 / 287.82 | 5 | 92 |
5 | 8 | -0.44 | 228 | 14.25 | 299 | 971 | 3.49 / 288.79 | 5 | 132 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 60 | 14.40 | 473 | 409 | 0.41 / 282.17 | 5 | 11 |
2 | 3 | 1050.76 | 1 | 13.82 | 1992 | 28 | 0.44 / 282.20 | 5 | 10 |
3 | 7 | 1093.72 | 80 | 12.90 | 1916 | 1977 | 2.41 / 284.17 | 10 | 72 |
4 | 13 | 27.16 | 20 | 14.43 | 380 | 110 | 2.52 / 284.28 | 5 | 92 |
5 | 8 | -0.40 | 230 | 14.23 | 310 | 1015 | 3.54 / 285.30 | 5 | 132 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 59 | 14.38 | 441 | 374 | 0.37 / 276.00 | 5 | 15 |
2 | 3 | 1024.92 | 1 | 13.62 | 1956 | 27 | 0.40 / 276.03 | 5 | 5 |
3 | 7 | 1514.56 | 81 | 12.54 | 2496 | 2535 | 2.94 / 278.56 | 5 | 55 |
4 | 13 | 1500.44 | 20 | 13.28 | 2598 | 690 | 3.63 / 279.25 | 5 | 69 |
5 | 13 | 1414.44 | 20 | 13.41 | 2433 | 653 | 4.28 / 279.91 | 5 | 73 |
6 | 13 | 991.60 | 20 | 13.73 | 1810 | 497 | 4.78 / 280.40 | 5 | 83 |
7 | 13 | 334.28 | 20 | 14.18 | 862 | 244 | 5.02 / 280.65 | 5 | 93 |
8 | 13 | 23.76 | 20 | 14.49 | 373 | 108 | 5.13 / 280.76 | 5 | 89 |
9 | 8 | -0.28 | 228 | 14.27 | 308 | 1002 | 6.13 / 281.76 | 5 | 132 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 62 | 14.38 | 462 | 412 | 0.41 / 272.60 | 5 | 15 |
2 | 3 | 955.28 | -1 | 14.38 | 462 | 0 | 0.00 / 272.60 | 5 | 15 |
3 | 7 | 1058.88 | 80 | 12.98 | 1891 | 1964 | 2.38 / 274.56 | 15 | 78 |
4 | 13 | 19.96 | 20 | 14.48 | 345 | 100 | 2.48 / 274.66 | 5 | 91 |
5 | 8 | -0.28 | 225 | 14.27 | 301 | 966 | 3.44 / 275.63 | 5 | 142 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 59 | 14.38 | 463 | 393 | 0.39 / 269.02 | 5 | 13 |
2 | 10 | 1000.60 | 3 | 14.12 | 1868 | 79 | 0.47 / 269.10 | 5 | 50 |
3 | 7 | 1084.00 | 80 | 12.97 | 1931 | 2004 | 2.48 / 271.11 | 5 | 78 |
4 | 13 | 23.44 | 20 | 14.47 | 349 | 101 | 2.58 / 271.21 | 5 | 93 |
5 | 8 | -0.36 | 228 | 14.26 | 301 | 979 | 3.56 / 272.19 | 5 | 142 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 60 | 14.45 | 435 | 377 | 0.38 / 265.60 | 5 | 12 |
2 | 7 | 1043.68 | 81 | 13.03 | 1865 | 1968 | 2.35 / 267.57 | 12 | 78 |
3 | 13 | 17.04 | 20 | 14.49 | 334 | 97 | 2.44 / 267.67 | 5 | 92 |
4 | 8 | -0.44 | 223 | 14.26 | 303 | 964 | 3.41 / 268.63 | 5 | 130 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 60 | 14.40 | 454 | 392 | 0.39 / 260.28 | 5 | 15 |
2 | 3 | 965.48 | -1 | 14.40 | 454 | 0 | 0.00 / 260.28 | 5 | 15 |
3 | 7 | 1252.12 | 81 | 12.75 | 2158 | 2229 | 2.62 / 262.51 | 15 | 63 |
4 | 13 | 1249.60 | 20 | 13.45 | 2196 | 591 | 3.21 / 263.10 | 5 | 77 |
5 | 13 | 1166.12 | 20 | 13.55 | 2087 | 566 | 3.78 / 263.66 | 5 | 80 |
6 | 13 | 744.80 | 20 | 13.89 | 1457 | 405 | 4.18 / 264.07 | 5 | 89 |
7 | 13 | 95.08 | 20 | 14.44 | 475 | 137 | 4.32 / 264.20 | 5 | 93 |
8 | 8 | -0.24 | 237 | 14.33 | 301 | 1022 | 5.34 / 265.23 | 5 | 142 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 61 | 14.39 | 460 | 404 | 0.40 / 256.79 | 5 | 15 |
2 | 3 | 941.44 | -1 | 14.39 | 460 | 0 | 0.00 / 256.79 | 5 | 15 |
3 | 7 | 1048.92 | 81 | 13.05 | 1892 | 2000 | 2.40 / 258.79 | 15 | 78 |
4 | 13 | 17.16 | 20 | 14.50 | 356 | 103 | 2.51 / 258.89 | 5 | 91 |
5 | 8 | -0.48 | 220 | 14.28 | 315 | 990 | 3.50 / 259.88 | 5 | 137 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 60 | 14.38 | 474 | 409 | 0.41 / 253.23 | 5 | 18 |
2 | 3 | 1042.32 | 1 | 13.97 | 2001 | 28 | 0.44 / 253.26 | 5 | 13 |
3 | 7 | 1077.32 | 80 | 13.03 | 1939 | 2021 | 2.46 / 255.28 | 13 | 78 |
4 | 13 | 8.76 | 20 | 14.52 | 336 | 98 | 2.56 / 255.38 | 5 | 89 |
5 | 8 | -0.32 | 223 | 14.28 | 318 | 1013 | 3.57 / 256.39 | 5 | 137 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 60 | 14.42 | 448 | 388 | 0.39 / 249.81 | 5 | 16 |
2 | 7 | 1028.68 | 80 | 13.18 | 1845 | 1945 | 2.33 / 251.76 | 16 | 80 |
3 | 13 | 15.76 | 20 | 14.53 | 342 | 99 | 2.43 / 251.86 | 5 | 91 |
4 | 8 | -0.52 | 218 | 14.29 | 309 | 963 | 3.39 / 252.82 | 5 | 133 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 60 | 14.41 | 461 | 399 | 0.40 / 244.62 | 5 | 18 |
2 | 7 | 1191.84 | 80 | 12.94 | 2095 | 2169 | 2.57 / 246.78 | 18 | 69 |
3 | 13 | 1170.92 | 20 | 13.57 | 2084 | 566 | 3.13 / 247.35 | 5 | 79 |
4 | 13 | 1084.08 | 20 | 13.68 | 1977 | 541 | 3.67 / 247.89 | 5 | 83 |
5 | 13 | 660.80 | 20 | 14.01 | 1330 | 373 | 4.05 / 248.26 | 5 | 91 |
6 | 13 | 52.84 | 20 | 14.53 | 423 | 123 | 4.17 / 248.39 | 5 | 89 |
7 | 8 | -0.08 | 232 | 14.33 | 312 | 1037 | 5.21 / 249.42 | 5 | 130 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 60 | 14.42 | 456 | 395 | 0.39 / 241.19 | 5 | 17 |
2 | 7 | 1042.60 | 80 | 13.20 | 1870 | 1975 | 2.37 / 243.16 | 17 | 80 |
3 | 8 | 0.04 | 239 | 14.33 | 308 | 1055 | 3.42 / 244.22 | 5 | 136 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 60 | 14.43 | 460 | 398 | 0.40 / 237.70 | 5 | 18 |
2 | 7 | 1065.48 | 80 | 13.16 | 1909 | 2010 | 2.41 / 239.71 | 5 | 79 |
3 | 13 | 4.56 | 20 | 14.58 | 318 | 93 | 2.50 / 239.80 | 5 | 85 |
4 | 8 | -0.28 | 220 | 14.33 | 314 | 990 | 3.49 / 240.79 | 5 | 139 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 60 | 14.47 | 452 | 392 | 0.39 / 234.27 | 5 | 15 |
2 | 7 | 1038.80 | 81 | 13.25 | 1859 | 1995 | 2.39 / 236.27 | 15 | 79 |
3 | 8 | -0.16 | 237 | 14.36 | 304 | 1035 | 3.42 / 237.30 | 5 | 133 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 60 | 14.46 | 441 | 383 | 0.38 / 227.72 | 5 | 17 |
2 | 7 | 1730.96 | 80 | 12.69 | 2812 | 2855 | 3.24 / 230.58 | 17 | 53 |
3 | 13 | 1676.72 | 20 | 13.40 | 2853 | 765 | 4.00 / 231.34 | 5 | 71 |
4 | 13 | 1584.84 | 20 | 13.49 | 2688 | 725 | 4.73 / 232.06 | 5 | 74 |
5 | 13 | 1036.72 | 20 | 13.84 | 1872 | 518 | 5.25 / 232.58 | 5 | 87 |
6 | 13 | 288.52 | 20 | 14.34 | 809 | 232 | 5.48 / 232.82 | 5 | 91 |
7 | 8 | 0.00 | 242 | 14.39 | 306 | 1066 | 6.54 / 233.88 | 5 | 138 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 60 | 14.49 | 453 | 394 | 0.39 / 224.28 | 5 | 15 |
2 | 7 | 1068.60 | 81 | 13.21 | 1910 | 2044 | 2.44 / 226.32 | 5 | 78 |
3 | 8 | -0.20 | 240 | 14.38 | 295 | 1018 | 3.46 / 227.34 | 5 | 149 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 61 | 14.48 | 441 | 390 | 0.39 / 220.87 | 5 | 16 |
2 | 3 | 935.36 | -1 | 14.48 | 441 | 0 | 0.00 / 220.87 | 5 | 16 |
3 | 7 | 1045.80 | 80 | 13.27 | 1865 | 1980 | 2.37 / 222.85 | 16 | 79 |
4 | 13 | 38.32 | 20 | 14.58 | 370 | 108 | 2.48 / 222.95 | 5 | 85 |
5 | 8 | -0.12 | 216 | 14.37 | 299 | 928 | 3.41 / 223.88 | 5 | 132 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 60 | 14.54 | 437 | 381 | 0.38 / 217.49 | 5 | 12 |
2 | 7 | 1046.08 | 81 | 13.28 | 1859 | 2000 | 2.38 / 219.49 | 12 | 79 |
3 | 8 | -0.32 | 235 | 14.39 | 293 | 991 | 3.37 / 220.48 | 5 | 135 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 60 | 14.43 | 458 | 397 | 0.40 / 211.19 | 5 | 13 |
2 | 7 | 1629.80 | 80 | 12.79 | 2684 | 2746 | 3.14 / 213.94 | 13 | 56 |
3 | 13 | 1581.64 | 20 | 13.46 | 2688 | 724 | 3.87 / 214.66 | 5 | 71 |
4 | 13 | 1492.12 | 20 | 13.55 | 2561 | 694 | 4.56 / 215.36 | 5 | 76 |
5 | 13 | 953.20 | 20 | 13.91 | 1761 | 490 | 5.05 / 215.85 | 5 | 89 |
6 | 13 | 295.84 | 20 | 14.36 | 789 | 227 | 5.28 / 216.07 | 5 | 95 |
7 | 13 | 43.76 | 20 | 14.62 | 371 | 108 | 5.39 / 216.18 | 5 | 84 |
8 | 8 | -0.04 | 218 | 14.38 | 295 | 925 | 6.31 / 217.10 | 5 | 135 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 58 | 14.46 | 481 | 403 | 0.40 / 207.47 | 5 | 14 |
2 | 3 | 1113.04 | 3 | 14.35 | 2025 | 87 | 0.49 / 207.56 | 5 | 68 |
3 | 7 | 1107.64 | 81 | 13.21 | 1972 | 2110 | 2.60 / 209.67 | 68 | 81 |
4 | 13 | 26.12 | 20 | 14.57 | 377 | 110 | 2.71 / 209.78 | 5 | 90 |
5 | 8 | -0.40 | 220 | 14.32 | 322 | 1014 | 3.72 / 210.79 | 5 | 138 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 60 | 14.47 | 454 | 394 | 0.39 / 203.90 | 5 | 17 |
2 | 3 | 956.40 | -1 | 14.47 | 454 | 0 | 0.00 / 203.90 | 5 | 17 |
3 | 7 | 1060.36 | 80 | 13.29 | 1895 | 2015 | 2.41 / 205.91 | 17 | 83 |
4 | 13 | 36.44 | 20 | 14.55 | 405 | 118 | 2.53 / 206.03 | 5 | 94 |
5 | 8 | -0.20 | 220 | 14.30 | 330 | 1038 | 3.56 / 207.07 | 5 | 130 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 60 | 14.52 | 462 | 402 | 0.40 / 200.39 | 5 | 11 |
2 | 7 | 1056.64 | 81 | 13.29 | 1893 | 2038 | 2.44 / 202.43 | 11 | 82 |
3 | 8 | 0.20 | 237 | 14.33 | 316 | 1073 | 3.51 / 203.50 | 5 | 131 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 60 | 14.52 | 423 | 369 | 0.37 / 193.09 | 5 | 13 |
2 | 7 | 2006.40 | 81 | 12.54 | 3211 | 3262 | 3.63 / 196.35 | 5 | 44 |
3 | 13 | 1938.04 | 20 | 13.32 | 3202 | 853 | 4.48 / 197.20 | 5 | 62 |
4 | 13 | 1737.12 | 20 | 13.51 | 2916 | 788 | 5.27 / 197.99 | 5 | 70 |
5 | 13 | 1199.80 | 20 | 13.81 | 2084 | 576 | 5.85 / 198.57 | 5 | 84 |
6 | 13 | 642.40 | 20 | 14.13 | 1266 | 358 | 6.20 / 198.93 | 5 | 93 |
7 | 13 | 47.20 | 20 | 14.62 | 365 | 107 | 6.31 / 199.03 | 5 | 90 |
8 | 13 | 25.80 | 20 | 14.59 | 326 | 95 | 6.41 / 199.13 | 5 | 90 |
9 | 8 | -0.28 | 206 | 14.40 | 291 | 863 | 7.27 / 199.99 | 5 | 136 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 60 | 14.53 | 418 | 364 | 0.36 / 189.75 | 5 | 12 |
2 | 7 | 1057.00 | 81 | 13.33 | 1860 | 2008 | 2.37 / 191.76 | 12 | 82 |
3 | 13 | 34.28 | 20 | 14.60 | 343 | 100 | 2.47 / 191.86 | 5 | 92 |
4 | 8 | -0.20 | 216 | 14.39 | 278 | 864 | 3.34 / 192.72 | 5 | 132 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 60 | 14.52 | 417 | 363 | 0.36 / 186.40 | 5 | 12 |
2 | 7 | 1082.12 | 80 | 13.31 | 1892 | 2015 | 2.38 / 188.41 | 5 | 81 |
3 | 13 | 44.68 | 20 | 14.60 | 359 | 105 | 2.48 / 188.52 | 5 | 91 |
4 | 8 | -0.48 | 218 | 14.39 | 276 | 866 | 3.35 / 189.38 | 5 | 137 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 60 | 14.57 | 409 | 358 | 0.36 / 183.04 | 5 | 10 |
2 | 7 | 1079.68 | 81 | 13.30 | 1906 | 2053 | 2.41 / 185.09 | 5 | 81 |
3 | 13 | 22.56 | 20 | 14.64 | 318 | 93 | 2.50 / 185.19 | 5 | 87 |
4 | 8 | -0.36 | 216 | 14.41 | 273 | 850 | 3.35 / 186.04 | 5 | 140 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 60 | 14.58 | 405 | 354 | 0.35 / 179.72 | 5 | 9 |
2 | 7 | 1057.68 | 81 | 13.36 | 1860 | 2013 | 2.37 / 181.74 | 9 | 81 |
3 | 13 | 35.12 | 20 | 14.62 | 345 | 101 | 2.47 / 181.84 | 5 | 89 |
4 | 8 | -0.44 | 213 | 14.40 | 276 | 847 | 3.31 / 182.68 | 5 | 133 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 60 | 14.55 | 406 | 354 | 0.35 / 172.51 | 5 | 11 |
2 | 7 | 2006.12 | 81 | 12.56 | 3208 | 3264 | 3.62 / 175.77 | 11 | 44 |
3 | 13 | 1944.72 | 20 | 13.33 | 3205 | 854 | 4.47 / 176.63 | 5 | 60 |
4 | 13 | 1848.28 | 20 | 13.41 | 3060 | 821 | 5.29 / 177.45 | 5 | 65 |
5 | 13 | 1197.72 | 20 | 13.82 | 2086 | 577 | 5.87 / 178.03 | 5 | 83 |
6 | 13 | 634.20 | 20 | 14.15 | 1254 | 355 | 6.22 / 178.38 | 5 | 94 |
7 | 13 | 44.84 | 20 | 14.66 | 354 | 104 | 6.33 / 178.49 | 5 | 86 |
8 | 8 | -0.16 | 228 | 14.45 | 268 | 883 | 7.21 / 179.37 | 5 | 140 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 59 | 14.54 | 415 | 356 | 0.36 / 169.13 | 5 | 13 |
2 | 3 | 1025.72 | 1 | 14.29 | 1923 | 27 | 0.38 / 169.16 | 5 | 5 |
3 | 7 | 1098.24 | 81 | 13.34 | 1917 | 2071 | 2.45 / 171.23 | 5 | 81 |
4 | 13 | 23.24 | 20 | 14.64 | 318 | 93 | 2.55 / 171.32 | 5 | 90 |
5 | 8 | -0.40 | 213 | 14.42 | 272 | 835 | 3.38 / 172.16 | 5 | 131 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 61 | 14.53 | 409 | 363 | 0.36 / 165.80 | 5 | 12 |
2 | 3 | 962.68 | -1 | 14.53 | 409 | 0 | 0.00 / 165.80 | 5 | 12 |
3 | 7 | 1079.52 | 80 | 13.36 | 1891 | 2021 | 2.38 / 167.82 | 12 | 84 |
4 | 13 | 22.12 | 20 | 14.64 | 322 | 94 | 2.48 / 167.91 | 5 | 90 |
5 | 8 | -0.24 | 216 | 14.41 | 276 | 859 | 3.34 / 168.77 | 5 | 130 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 61 | 14.51 | 417 | 369 | 0.37 / 162.49 | 5 | 12 |
2 | 7 | 1050.44 | 80 | 13.38 | 1852 | 1982 | 2.35 / 164.47 | 12 | 85 |
3 | 13 | 34.40 | 20 | 14.61 | 345 | 101 | 2.45 / 164.57 | 5 | 93 |
4 | 8 | -0.28 | 216 | 14.40 | 278 | 865 | 3.32 / 165.44 | 5 | 131 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 61 | 14.55 | 409 | 363 | 0.36 / 159.15 | 5 | 11 |
2 | 7 | 1059.08 | 81 | 13.37 | 1853 | 2007 | 2.37 / 161.16 | 11 | 83 |
3 | 13 | 33.44 | 20 | 14.63 | 341 | 100 | 2.47 / 161.26 | 5 | 93 |
4 | 8 | -0.40 | 216 | 14.40 | 276 | 858 | 3.33 / 162.12 | 5 | 132 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 61 | 14.55 | 413 | 367 | 0.37 / 155.84 | 5 | 9 |
2 | 7 | 1064.48 | 80 | 13.37 | 1866 | 1996 | 2.36 / 157.83 | 9 | 86 |
3 | 13 | 35.96 | 20 | 14.63 | 346 | 101 | 2.46 / 157.94 | 5 | 92 |
4 | 8 | -0.40 | 216 | 14.41 | 275 | 856 | 3.32 / 158.79 | 5 | 138 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 61 | 14.57 | 405 | 360 | 0.36 / 152.55 | 5 | 9 |
2 | 7 | 1041.40 | 80 | 13.40 | 1828 | 1960 | 2.32 / 154.51 | 9 | 85 |
3 | 13 | 37.24 | 20 | 14.63 | 346 | 101 | 2.42 / 154.62 | 5 | 93 |
4 | 8 | -0.44 | 216 | 14.41 | 275 | 856 | 3.28 / 155.47 | 5 | 136 |
Average= | 5.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 61 | 14.57 | 407 | 362 | 0.36 / 149.20 | 5 | 9 |
2 | 7 | 1060.60 | 81 | 13.38 | 1878 | 2035 | 2.40 / 151.24 | 9 | 85 |
3 | 13 | 35.36 | 20 | 14.63 | 346 | 101 | 2.50 / 151.34 | 5 | 94 |
4 | 8 | 0.16 | 213 | 14.40 | 279 | 856 | 3.35 / 152.19 | 5 | 134 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 60 | 14.61 | 408 | 358 | 0.36 / 145.85 | 5 | 8 |
2 | 7 | 1069.88 | 81 | 13.43 | 1870 | 2034 | 2.39 / 147.88 | 8 | 85 |
3 | 13 | 38.64 | 20 | 14.64 | 350 | 102 | 2.49 / 147.98 | 5 | 95 |
4 | 8 | -0.52 | 216 | 14.41 | 275 | 856 | 3.35 / 148.84 | 5 | 132 |
Average= | 5.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 60 | 14.59 | 404 | 354 | 0.35 / 138.78 | 5 | 9 |
2 | 7 | 2006.08 | 81 | 12.63 | 3172 | 3245 | 3.60 / 142.02 | 9 | 45 |
3 | 13 | 1938.64 | 20 | 13.33 | 3196 | 852 | 4.45 / 142.87 | 5 | 63 |
4 | 13 | 1737.84 | 20 | 13.55 | 2852 | 773 | 5.22 / 143.65 | 5 | 68 |
5 | 13 | 1190.44 | 20 | 13.84 | 2062 | 571 | 5.79 / 144.22 | 5 | 85 |
6 | 13 | 433.40 | 20 | 14.30 | 968 | 277 | 6.07 / 144.49 | 5 | 99 |
7 | 13 | 50.84 | 20 | 14.67 | 369 | 108 | 6.18 / 144.60 | 5 | 93 |
8 | 13 | 12.56 | 20 | 14.68 | 299 | 88 | 6.27 / 144.69 | 5 | 89 |
9 | 8 | -0.40 | 204 | 14.44 | 272 | 801 | 7.07 / 145.49 | 5 | 138 |
Average= | 5.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 61 | 14.58 | 405 | 360 | 0.36 / 135.49 | 5 | 8 |
2 | 7 | 1054.16 | 80 | 13.41 | 1851 | 1986 | 2.35 / 137.47 | 8 | 87 |
3 | 13 | 38.92 | 20 | 14.63 | 348 | 102 | 2.45 / 137.58 | 5 | 96 |
4 | 8 | -0.36 | 216 | 14.44 | 271 | 845 | 3.29 / 138.42 | 5 | 129 |
Average= | 5.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 61 | 14.57 | 410 | 364 | 0.36 / 132.19 | 5 | 9 |
2 | 7 | 1060.76 | 80 | 13.41 | 1869 | 2005 | 2.37 / 134.19 | 9 | 87 |
3 | 13 | 37.24 | 20 | 14.64 | 345 | 101 | 2.47 / 134.29 | 5 | 96 |
4 | 8 | -0.44 | 213 | 14.44 | 272 | 837 | 3.31 / 135.13 | 5 | 129 |
Average= | 5.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 61 | 14.57 | 412 | 366 | 0.37 / 128.84 | 5 | 9 |
2 | 7 | 1064.80 | 81 | 13.41 | 1870 | 2031 | 2.40 / 130.87 | 9 | 86 |
3 | 13 | 36.20 | 20 | 14.65 | 344 | 101 | 2.50 / 130.97 | 5 | 93 |
4 | 8 | -0.40 | 213 | 14.42 | 277 | 851 | 3.35 / 131.82 | 5 | 131 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 60 | 14.50 | 443 | 385 | 0.39 / 125.48 | 5 | 19 |
2 | 7 | 1076.64 | 80 | 13.43 | 1891 | 2032 | 2.42 / 127.51 | 5 | 86 |
3 | 13 | 26.76 | 20 | 14.68 | 329 | 97 | 2.51 / 127.60 | 5 | 91 |
4 | 8 | -0.40 | 218 | 14.44 | 276 | 869 | 3.38 / 128.47 | 5 | 145 |
Average= | 5.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 60 | 14.60 | 415 | 364 | 0.36 / 122.05 | 5 | 9 |
2 | 7 | 1078.20 | 80 | 13.42 | 1898 | 2038 | 2.40 / 124.09 | 5 | 86 |
3 | 13 | 0.68 | 20 | 14.69 | 294 | 86 | 2.49 / 124.18 | 5 | 101 |
4 | 8 | -0.32 | 221 | 14.37 | 287 | 911 | 3.40 / 125.09 | 5 | 144 |
Average= | 5.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 60 | 14.61 | 411 | 360 | 0.36 / 118.70 | 5 | 9 |
2 | 7 | 1082.80 | 80 | 13.42 | 1894 | 2033 | 2.39 / 120.74 | 5 | 85 |
3 | 13 | 42.80 | 20 | 14.66 | 352 | 103 | 2.50 / 120.84 | 5 | 92 |
4 | 8 | -0.24 | 216 | 14.45 | 273 | 852 | 3.35 / 121.69 | 5 | 141 |
Average= | 6.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 60 | 14.63 | 407 | 357 | 0.36 / 115.33 | 6 | 7 |
2 | 7 | 1084.16 | 80 | 13.44 | 1901 | 2044 | 2.40 / 117.38 | 5 | 86 |
3 | 13 | 45.92 | 20 | 14.67 | 360 | 106 | 2.51 / 117.48 | 5 | 91 |
4 | 8 | -0.32 | 216 | 14.45 | 275 | 858 | 3.37 / 118.34 | 5 | 136 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 60 | 14.70 | 407 | 359 | 0.36 / 111.96 | 6 | 7 |
2 | 7 | 1069.88 | 81 | 13.50 | 1883 | 2059 | 2.42 / 114.02 | 7 | 88 |
3 | 13 | 41.44 | 20 | 14.70 | 355 | 104 | 2.52 / 114.13 | 5 | 91 |
4 | 8 | -0.60 | 213 | 14.47 | 276 | 851 | 3.37 / 114.98 | 5 | 135 |
Average= | 6.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 60 | 14.69 | 409 | 360 | 0.36 / 104.76 | 6 | 8 |
2 | 7 | 2028.64 | 81 | 12.81 | 3277 | 3400 | 3.76 / 108.16 | 8 | 47 |
3 | 13 | 1958.56 | 20 | 13.43 | 3217 | 864 | 4.62 / 109.03 | 5 | 64 |
4 | 13 | 1758.00 | 20 | 13.60 | 2908 | 791 | 5.42 / 109.82 | 5 | 70 |
5 | 13 | 1100.12 | 20 | 13.94 | 1928 | 538 | 5.95 / 110.36 | 5 | 88 |
6 | 13 | 438.64 | 20 | 14.34 | 972 | 279 | 6.23 / 110.63 | 5 | 97 |
7 | 13 | 51.80 | 20 | 14.77 | 368 | 109 | 6.34 / 110.74 | 5 | 90 |
8 | 8 | -0.44 | 220 | 14.54 | 269 | 860 | 7.20 / 111.60 | 5 | 131 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 60 | 14.72 | 410 | 362 | 0.36 / 97.70 | 6 | 8 |
2 | 7 | 2007.56 | 80 | 12.85 | 3186 | 3275 | 3.64 / 100.98 | 8 | 47 |
3 | 13 | 1940.80 | 20 | 13.45 | 3177 | 855 | 4.49 / 101.83 | 5 | 62 |
4 | 13 | 1644.08 | 20 | 13.66 | 2760 | 754 | 5.25 / 102.59 | 5 | 74 |
5 | 13 | 1106.28 | 20 | 13.94 | 1949 | 543 | 5.79 / 103.13 | 5 | 87 |
6 | 13 | 459.08 | 20 | 14.32 | 1009 | 289 | 6.08 / 103.42 | 5 | 98 |
7 | 13 | 60.28 | 20 | 14.75 | 388 | 114 | 6.19 / 103.53 | 5 | 91 |
8 | 8 | -0.52 | 220 | 14.54 | 272 | 870 | 7.06 / 104.40 | 5 | 134 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 60 | 14.71 | 409 | 361 | 0.36 / 90.59 | 6 | 8 |
2 | 7 | 2005.84 | 80 | 12.89 | 3162 | 3261 | 3.62 / 93.85 | 8 | 48 |
3 | 13 | 1937.88 | 20 | 13.44 | 3178 | 854 | 4.48 / 94.71 | 5 | 62 |
4 | 13 | 1740.20 | 20 | 13.61 | 2882 | 784 | 5.26 / 95.49 | 5 | 70 |
5 | 13 | 1100.20 | 20 | 13.93 | 1944 | 542 | 5.80 / 96.03 | 5 | 87 |
6 | 13 | 455.56 | 20 | 14.33 | 1008 | 289 | 6.09 / 96.32 | 5 | 98 |
7 | 13 | 59.44 | 20 | 14.76 | 388 | 115 | 6.21 / 96.44 | 5 | 91 |
8 | 13 | 15.04 | 20 | 14.79 | 306 | 91 | 6.30 / 96.53 | 5 | 86 |
9 | 8 | -0.48 | 202 | 14.52 | 277 | 812 | 7.11 / 97.34 | 5 | 137 |
Average= | 6.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 60 | 14.72 | 417 | 368 | 0.37 / 83.44 | 6 | 8 |
2 | 7 | 2006.04 | 80 | 12.90 | 3203 | 3305 | 3.67 / 86.75 | 8 | 49 |
3 | 13 | 1937.76 | 20 | 13.45 | 3196 | 860 | 4.53 / 87.61 | 5 | 64 |
4 | 13 | 1739.40 | 20 | 13.61 | 2875 | 783 | 5.32 / 88.39 | 5 | 69 |
5 | 13 | 1095.28 | 20 | 13.95 | 1929 | 538 | 5.85 / 88.93 | 5 | 87 |
6 | 13 | 451.44 | 20 | 14.34 | 1006 | 289 | 6.14 / 89.22 | 5 | 98 |
7 | 13 | 55.48 | 20 | 14.77 | 382 | 113 | 6.26 / 89.33 | 5 | 91 |
8 | 8 | -0.48 | 223 | 14.54 | 278 | 901 | 7.16 / 90.23 | 5 | 138 |
Average= | 6.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 60 | 14.73 | 407 | 360 | 0.36 / 76.29 | 5 | 8 |
2 | 7 | 2006.92 | 80 | 12.91 | 3218 | 3324 | 3.68 / 79.61 | 8 | 49 |
3 | 13 | 1938.64 | 20 | 13.45 | 3203 | 862 | 4.54 / 80.47 | 5 | 64 |
4 | 13 | 1740.04 | 20 | 13.61 | 2885 | 785 | 5.33 / 81.26 | 5 | 68 |
5 | 13 | 1092.08 | 20 | 13.94 | 1923 | 536 | 5.87 / 81.79 | 5 | 87 |
6 | 13 | 439.76 | 20 | 14.35 | 988 | 284 | 6.15 / 82.08 | 5 | 98 |
7 | 13 | 48.96 | 20 | 14.79 | 373 | 110 | 6.26 / 82.19 | 5 | 91 |
8 | 8 | -0.52 | 220 | 14.54 | 277 | 886 | 7.15 / 83.07 | 5 | 137 |
Average= | 6.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 60 | 14.73 | 409 | 361 | 0.36 / 69.18 | 5 | 8 |
2 | 7 | 2007.72 | 80 | 12.94 | 3199 | 3312 | 3.67 / 72.49 | 8 | 50 |
3 | 13 | 1943.56 | 20 | 13.47 | 3161 | 852 | 4.52 / 73.34 | 5 | 62 |
4 | 13 | 1648.76 | 20 | 13.66 | 2745 | 750 | 5.27 / 74.09 | 5 | 70 |
5 | 13 | 1110.12 | 20 | 13.93 | 1954 | 544 | 5.82 / 74.63 | 5 | 87 |
6 | 13 | 456.92 | 20 | 14.34 | 1012 | 290 | 6.11 / 74.93 | 5 | 98 |
7 | 13 | 56.28 | 20 | 14.77 | 388 | 115 | 6.22 / 75.04 | 5 | 92 |
8 | 8 | -0.44 | 220 | 14.53 | 278 | 889 | 7.11 / 75.93 | 5 | 136 |
Average= | 6.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 60 | 14.75 | 406 | 359 | 0.36 / 62.05 | 5 | 8 |
2 | 7 | 2029.68 | 81 | 12.93 | 3197 | 3348 | 3.71 / 65.40 | 8 | 49 |
3 | 13 | 1957.76 | 20 | 13.46 | 3227 | 869 | 4.58 / 66.27 | 5 | 63 |
4 | 13 | 1756.32 | 20 | 13.61 | 2927 | 797 | 5.37 / 67.07 | 5 | 71 |
5 | 13 | 1010.96 | 20 | 13.99 | 1804 | 505 | 5.88 / 67.57 | 5 | 89 |
6 | 13 | 371.08 | 20 | 14.43 | 877 | 253 | 6.13 / 67.82 | 5 | 97 |
7 | 13 | 67.20 | 20 | 14.78 | 399 | 118 | 6.25 / 67.94 | 5 | 91 |
8 | 8 | -0.48 | 220 | 14.55 | 273 | 874 | 7.12 / 68.82 | 5 | 142 |
Average= | 6.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 60 | 14.74 | 406 | 359 | 0.36 / 54.96 | 5 | 8 |
2 | 7 | 2006.92 | 40 | 13.26 | 3194 | 1694 | 2.05 / 56.65 | 8 | 50 |
3 | 13 | 2069.28 | 20 | 13.41 | 3363 | 902 | 2.96 / 57.56 | 5 | 56 |
4 | 13 | 2032.24 | 20 | 13.46 | 3307 | 890 | 3.85 / 58.45 | 5 | 58 |
5 | 13 | 1950.28 | 20 | 13.53 | 3185 | 862 | 4.71 / 59.31 | 5 | 62 |
6 | 13 | 1640.44 | 20 | 13.66 | 2730 | 746 | 5.45 / 60.05 | 5 | 72 |
7 | 13 | 983.04 | 20 | 14.01 | 1756 | 492 | 5.95 / 60.55 | 5 | 89 |
8 | 13 | 232.64 | 20 | 14.57 | 674 | 196 | 6.14 / 60.74 | 5 | 96 |
9 | 13 | 58.32 | 20 | 14.80 | 376 | 111 | 6.25 / 60.85 | 5 | 87 |
10 | 8 | -0.48 | 216 | 14.57 | 267 | 840 | 7.09 / 61.69 | 5 | 136 |
Average= | 6.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 60 | 14.73 | 405 | 358 | 0.36 / 47.94 | 5 | 9 |
2 | 7 | 2030.44 | 40 | 13.22 | 3314 | 1752 | 2.11 / 49.69 | 9 | 53 |
3 | 13 | 2089.88 | 20 | 13.40 | 3399 | 911 | 3.02 / 50.60 | 5 | 56 |
4 | 13 | 2047.52 | 20 | 13.46 | 3329 | 896 | 3.92 / 51.50 | 5 | 57 |
5 | 13 | 1962.92 | 20 | 13.51 | 3186 | 861 | 4.78 / 52.36 | 5 | 61 |
6 | 13 | 1447.64 | 20 | 13.75 | 2449 | 673 | 5.45 / 53.03 | 5 | 78 |
7 | 13 | 833.32 | 20 | 14.09 | 1547 | 436 | 5.89 / 53.47 | 5 | 93 |
8 | 13 | 201.60 | 20 | 14.61 | 623 | 182 | 6.07 / 53.65 | 5 | 96 |
9 | 13 | 45.56 | 20 | 14.81 | 354 | 105 | 6.17 / 53.76 | 5 | 86 |
10 | 8 | -0.40 | 216 | 14.57 | 268 | 843 | 7.02 / 54.60 | 5 | 139 |
Average= | 6.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 60 | 14.72 | 402 | 355 | 0.36 / 40.94 | 5 | 10 |
2 | 7 | 2007.92 | 40 | 13.24 | 3196 | 1693 | 2.05 / 42.63 | 10 | 49 |
3 | 13 | 2069.56 | 20 | 13.41 | 3345 | 897 | 2.94 / 43.53 | 5 | 55 |
4 | 13 | 2032.04 | 20 | 13.45 | 3304 | 889 | 3.83 / 44.42 | 5 | 58 |
5 | 13 | 1949.52 | 20 | 13.48 | 3182 | 858 | 4.69 / 45.28 | 5 | 61 |
6 | 13 | 1541.68 | 20 | 13.69 | 2592 | 710 | 5.40 / 45.99 | 5 | 75 |
7 | 13 | 899.60 | 20 | 14.03 | 1648 | 462 | 5.86 / 46.45 | 5 | 91 |
8 | 13 | 259.28 | 20 | 14.55 | 705 | 205 | 6.07 / 46.66 | 5 | 95 |
9 | 13 | 36.04 | 20 | 14.84 | 334 | 99 | 6.17 / 46.75 | 5 | 83 |
10 | 8 | -0.32 | 213 | 14.54 | 267 | 827 | 6.99 / 47.58 | 5 | 130 |
Average= | 5.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 65 | 14.69 | 405 | 387 | 0.39 / 33.85 | 5 | 10 |
2 | 3 | 809.44 | -3 | 14.69 | 405 | 0 | 0.00 / 33.85 | 5 | 10 |
3 | 7 | 2027.40 | 40 | 13.21 | 3268 | 1727 | 2.11 / 35.58 | 10 | 51 |
4 | 13 | 2083.16 | 20 | 13.38 | 3377 | 904 | 3.02 / 36.48 | 5 | 56 |
5 | 13 | 2040.08 | 20 | 13.41 | 3326 | 892 | 3.91 / 37.37 | 5 | 57 |
6 | 13 | 1956.16 | 20 | 13.47 | 3211 | 865 | 4.77 / 38.24 | 5 | 62 |
7 | 13 | 1547.16 | 20 | 13.67 | 2584 | 706 | 5.48 / 38.94 | 5 | 73 |
8 | 13 | 1001.92 | 20 | 13.98 | 1769 | 495 | 5.98 / 39.44 | 5 | 88 |
9 | 13 | 247.36 | 20 | 14.57 | 690 | 201 | 6.18 / 39.64 | 5 | 95 |
10 | 13 | 64.04 | 20 | 14.79 | 380 | 112 | 6.29 / 39.75 | 5 | 86 |
11 | 8 | -0.40 | 218 | 14.56 | 263 | 835 | 7.12 / 40.59 | 5 | 150 |
Average= | 5.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 31 | 14.92 | 401 | 185 | 0.19 / 25.64 | 5 | 9 |
2 | 10 | 1122.40 | 9 | 14.42 | 1995 | 259 | 0.44 / 25.90 | 5 | 44 |
3 | 10 | 1199.32 | 7 | 14.29 | 2114 | 211 | 0.66 / 26.11 | 5 | 48 |
4 | 10 | 1259.32 | 6 | 14.27 | 2209 | 189 | 0.84 / 26.30 | 5 | 53 |
5 | 10 | 1300.32 | 4 | 14.31 | 2276 | 130 | 0.98 / 26.43 | 5 | 58 |
6 | 3 | 1357.40 | 9 | 14.23 | 2280 | 292 | 1.27 / 26.72 | 5 | 78 |
7 | 7 | 2027.76 | 40 | 13.17 | 3205 | 1688 | 2.96 / 28.41 | 78 | 49 |
8 | 13 | 2087.68 | 20 | 13.35 | 3355 | 896 | 3.85 / 29.31 | 5 | 53 |
9 | 13 | 2049.08 | 20 | 13.38 | 3325 | 890 | 4.74 / 30.19 | 5 | 58 |
10 | 13 | 1967.00 | 20 | 13.43 | 3203 | 860 | 5.60 / 31.06 | 5 | 61 |
11 | 13 | 1657.76 | 20 | 13.61 | 2718 | 740 | 6.34 / 31.80 | 5 | 69 |
12 | 13 | 1006.72 | 20 | 13.95 | 1770 | 494 | 6.84 / 32.29 | 5 | 88 |
13 | 13 | 360.44 | 20 | 14.44 | 848 | 245 | 7.08 / 32.53 | 5 | 95 |
14 | 13 | 65.44 | 20 | 14.81 | 372 | 110 | 7.19 / 32.64 | 5 | 83 |
15 | 8 | -0.36 | 218 | 14.57 | 258 | 819 | 8.01 / 33.46 | 5 | 140 |
Average= | 5.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 62 | 14.69 | 406 | 370 | 0.37 / 20.11 | 5 | 11 |
2 | 3 | 870.24 | -2 | 14.69 | 406 | 0 | 0.00 / 20.11 | 5 | 11 |
3 | 7 | 1521.84 | 40 | 13.51 | 2549 | 1377 | 1.75 / 21.49 | 11 | 61 |
4 | 13 | 1598.40 | 20 | 13.59 | 2668 | 725 | 2.47 / 22.21 | 5 | 64 |
5 | 13 | 1583.40 | 20 | 13.60 | 2652 | 721 | 3.19 / 22.94 | 5 | 66 |
6 | 13 | 1508.16 | 20 | 13.65 | 2532 | 691 | 3.88 / 23.63 | 5 | 72 |
7 | 13 | 1108.96 | 20 | 13.90 | 1931 | 537 | 4.42 / 24.16 | 5 | 85 |
8 | 13 | 573.40 | 20 | 14.26 | 1161 | 331 | 4.75 / 24.49 | 5 | 96 |
9 | 13 | 121.88 | 20 | 14.74 | 464 | 137 | 4.89 / 24.63 | 5 | 87 |
10 | 8 | -0.12 | 223 | 14.58 | 253 | 823 | 5.71 / 25.45 | 5 | 131 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 68 | 14.64 | 401 | 399 | 0.40 / 14.35 | 5 | 12 |
2 | 3 | 721.80 | -4 | 14.64 | 401 | 0 | 0.00 / 14.35 | 5 | 12 |
3 | 7 | 1508.40 | 40 | 13.49 | 2520 | 1360 | 1.76 / 15.71 | 12 | 61 |
4 | 13 | 1587.80 | 20 | 13.56 | 2675 | 725 | 2.48 / 16.44 | 5 | 64 |
5 | 13 | 1578.16 | 20 | 13.57 | 2657 | 721 | 3.21 / 17.16 | 5 | 66 |
6 | 13 | 1503.08 | 20 | 13.63 | 2534 | 691 | 3.90 / 17.85 | 5 | 71 |
7 | 13 | 1199.04 | 20 | 13.83 | 2060 | 570 | 4.47 / 18.42 | 5 | 83 |
8 | 13 | 648.28 | 20 | 14.19 | 1254 | 356 | 4.82 / 18.78 | 5 | 90 |
9 | 13 | 102.04 | 20 | 14.76 | 430 | 127 | 4.95 / 18.90 | 5 | 83 |
10 | 8 | -0.28 | 228 | 14.57 | 252 | 837 | 5.79 / 19.74 | 5 | 151 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 31 | 14.76 | 406 | 186 | 0.19 / 7.48 | 5 | 12 |
2 | 10 | 1123.44 | 9 | 14.33 | 1967 | 254 | 0.44 / 7.73 | 5 | 46 |
3 | 10 | 1202.76 | 7 | 14.16 | 2099 | 208 | 0.65 / 7.94 | 5 | 49 |
4 | 10 | 1265.32 | 6 | 14.14 | 2199 | 187 | 0.83 / 8.12 | 5 | 54 |
5 | 10 | 1310.76 | 4 | 14.15 | 2272 | 129 | 0.96 / 8.25 | 5 | 58 |
6 | 3 | 1457.04 | 11 | 13.99 | 2370 | 365 | 1.33 / 8.62 | 5 | 75 |
7 | 7 | 1509.44 | 40 | 13.43 | 2454 | 1318 | 2.65 / 9.94 | 75 | 62 |
8 | 13 | 1587.76 | 20 | 13.52 | 2607 | 705 | 3.35 / 10.64 | 5 | 64 |
9 | 13 | 1596.32 | 20 | 13.51 | 2648 | 715 | 4.07 / 11.36 | 5 | 70 |
10 | 13 | 1524.60 | 20 | 13.57 | 2536 | 688 | 4.75 / 12.04 | 5 | 72 |
11 | 13 | 1230.00 | 20 | 13.76 | 2097 | 577 | 5.33 / 12.62 | 5 | 82 |
12 | 13 | 694.28 | 20 | 14.10 | 1305 | 368 | 5.70 / 12.99 | 5 | 89 |
13 | 13 | 140.04 | 20 | 14.68 | 488 | 143 | 5.84 / 13.13 | 5 | 89 |
14 | 13 | 1.00 | 20 | 14.89 | 254 | 76 | 5.92 / 13.21 | 5 | 75 |
15 | 8 | 0.00 | 206 | 14.51 | 250 | 747 | 6.67 / 13.96 | 5 | 132 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 31 | 14.84 | 377 | 173 | 0.17 / 1.58 | 6 | 6 |
2 | 10 | 1120.64 | 9 | 14.02 | 1998 | 252 | 0.43 / 1.83 | 5 | 37 |
3 | 3 | 1122.32 | 3 | 13.96 | 2000 | 84 | 0.51 / 1.92 | 5 | 37 |
4 | 7 | 1616.20 | 40 | 13.15 | 2657 | 1398 | 1.91 / 3.32 | 37 | 49 |
5 | 13 | 1521.84 | 20 | 13.44 | 2535 | 681 | 2.59 / 4.00 | 5 | 58 |
6 | 13 | 981.28 | 20 | 13.81 | 1734 | 479 | 3.07 / 4.48 | 5 | 79 |
7 | 13 | 330.68 | 20 | 14.32 | 792 | 227 | 3.29 / 4.70 | 5 | 90 |
8 | 8 | 326.92 | 265 | 13.75 | 710 | 2587 | 5.88 / 7.29 | 5 | 130 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 30 | 14.62 | 364 | 160 | 0.16 / 0.16 | 6 | 6 |
2 | 7 | 120.84 | 40 | 14.58 | 381 | 222 | 0.38 / 0.38 | 6 | 6 |
3 | 13 | 161.80 | 20 | 14.75 | 449 | 132 | 0.51 / 0.51 | 6 | 6 |
4 | 13 | 124.60 | 20 | 14.81 | 398 | 118 | 0.63 / 0.63 | 6 | 7 |
5 | 13 | 67.40 | 20 | 14.88 | 313 | 93 | 0.73 / 0.73 | 6 | 9 |
6 | 8 | 0.04 | 230 | 14.78 | 201 | 683 | 1.41 / 1.41 | 6 | 153 |
Average= | 1.41 (KJ/cycle) |