SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 93 | 10.76 | 339 | 339 | 0.34 / 1058.05 | 6 | 6 |
2 | 3 | 1043.08 | 2 | 9.13 | 981 | 18 | 0.36 / 1058.07 | 6 | 7 |
3 | 7 | 2001.28 | 106 | 6.53 | 1596 | 1105 | 1.46 / 1059.17 | 7 | 6 |
4 | 13 | 1955.20 | 36 | 6.50 | 1575 | 369 | 1.83 / 1059.54 | 6 | 6 |
5 | 13 | 1890.20 | 36 | 6.51 | 1534 | 360 | 2.19 / 1059.90 | 6 | 6 |
6 | 13 | 1815.08 | 36 | 6.55 | 1484 | 350 | 2.54 / 1060.25 | 6 | 6 |
7 | 13 | 1728.80 | 36 | 6.55 | 1432 | 338 | 2.88 / 1060.59 | 6 | 6 |
8 | 13 | 1630.12 | 36 | 6.59 | 1368 | 325 | 3.20 / 1060.91 | 6 | 7 |
9 | 13 | 1437.00 | 36 | 6.78 | 1248 | 305 | 3.51 / 1061.22 | 6 | 8 |
10 | 13 | 1237.84 | 36 | 6.97 | 1124 | 282 | 3.79 / 1061.50 | 6 | 10 |
11 | 13 | 1038.68 | 36 | 7.17 | 995 | 257 | 4.05 / 1061.75 | 6 | 13 |
12 | 13 | 730.96 | 36 | 7.66 | 791 | 218 | 4.26 / 1061.97 | 6 | 14 |
13 | 13 | 325.40 | 36 | 8.79 | 500 | 158 | 4.42 / 1062.13 | 6 | 14 |
14 | 13 | 120.00 | 36 | 9.53 | 349 | 120 | 4.54 / 1062.25 | 6 | 14 |
15 | 8 | 0.16 | 398 | 9.94 | 264 | 1044 | 5.59 / 1063.29 | 6 | 29 |
Average= | 6.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 93 | 10.97 | 330 | 337 | 0.34 / 1052.12 | 6 | 6 |
2 | 7 | 2001.16 | 105 | 8.15 | 1631 | 1396 | 1.73 / 1053.52 | 6 | 7 |
3 | 13 | 1937.48 | 36 | 8.30 | 1595 | 477 | 2.21 / 1053.99 | 6 | 8 |
4 | 13 | 1857.56 | 36 | 8.41 | 1552 | 470 | 2.68 / 1054.46 | 6 | 10 |
5 | 13 | 1762.88 | 36 | 8.46 | 1492 | 454 | 3.13 / 1054.92 | 6 | 11 |
6 | 13 | 1462.08 | 36 | 8.77 | 1298 | 410 | 3.54 / 1055.33 | 6 | 16 |
7 | 13 | 1250.76 | 36 | 8.99 | 1163 | 376 | 3.92 / 1055.70 | 6 | 20 |
8 | 13 | 726.52 | 36 | 9.68 | 810 | 282 | 4.20 / 1055.99 | 6 | 25 |
9 | 13 | 313.80 | 36 | 10.34 | 500 | 186 | 4.39 / 1056.17 | 6 | 20 |
10 | 13 | 59.16 | 36 | 10.74 | 309 | 119 | 4.51 / 1056.29 | 6 | 16 |
11 | 13 | 29.92 | 36 | 10.76 | 295 | 114 | 4.62 / 1056.41 | 6 | 17 |
12 | 8 | 0.04 | 450 | 10.84 | 267 | 1302 | 5.92 / 1057.71 | 6 | 35 |
Average= | 6.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 93 | 11.03 | 335 | 344 | 0.34 / 1046.22 | 6 | 6 |
2 | 7 | 2014.24 | 105 | 8.85 | 1649 | 1532 | 1.88 / 1047.76 | 6 | 9 |
3 | 13 | 1947.72 | 36 | 9.04 | 1620 | 527 | 2.40 / 1048.28 | 6 | 11 |
4 | 13 | 1856.76 | 36 | 9.18 | 1560 | 516 | 2.92 / 1048.80 | 6 | 14 |
5 | 13 | 1543.96 | 36 | 9.40 | 1370 | 464 | 3.38 / 1049.26 | 6 | 19 |
6 | 13 | 1238.60 | 36 | 9.65 | 1172 | 407 | 3.79 / 1049.67 | 6 | 25 |
7 | 13 | 725.28 | 36 | 10.14 | 818 | 299 | 4.09 / 1049.97 | 6 | 29 |
8 | 13 | 420.68 | 36 | 10.50 | 589 | 223 | 4.31 / 1050.19 | 6 | 26 |
9 | 13 | 106.24 | 36 | 10.87 | 343 | 134 | 4.44 / 1050.33 | 6 | 19 |
10 | 13 | 53.60 | 36 | 10.91 | 316 | 124 | 4.57 / 1050.45 | 6 | 18 |
11 | 8 | 0.04 | 450 | 10.99 | 270 | 1335 | 5.90 / 1051.78 | 6 | 39 |
Average= | 6.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 93 | 11.05 | 332 | 341 | 0.34 / 1040.32 | 6 | 6 |
2 | 7 | 2004.20 | 105 | 9.16 | 1650 | 1587 | 1.93 / 1041.90 | 6 | 10 |
3 | 13 | 1933.40 | 36 | 9.36 | 1617 | 545 | 2.47 / 1042.45 | 6 | 13 |
4 | 13 | 1844.88 | 36 | 9.50 | 1566 | 536 | 3.01 / 1042.98 | 6 | 17 |
5 | 13 | 1539.44 | 36 | 9.71 | 1369 | 479 | 3.49 / 1043.46 | 6 | 22 |
6 | 13 | 1030.20 | 36 | 10.08 | 1031 | 374 | 3.86 / 1043.84 | 6 | 29 |
7 | 13 | 728.44 | 36 | 10.33 | 819 | 305 | 4.17 / 1044.14 | 6 | 30 |
8 | 13 | 313.80 | 36 | 10.76 | 505 | 196 | 4.36 / 1044.34 | 6 | 22 |
9 | 13 | 52.80 | 36 | 11.00 | 304 | 120 | 4.48 / 1044.46 | 6 | 18 |
10 | 13 | 14.00 | 36 | 11.04 | 276 | 110 | 4.59 / 1044.57 | 6 | 19 |
11 | 8 | 0.04 | 450 | 11.05 | 264 | 1313 | 5.90 / 1045.88 | 6 | 37 |
Average= | 6.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 93 | 11.11 | 330 | 341 | 0.34 / 1034.49 | 6 | 6 |
2 | 7 | 2008.04 | 106 | 9.35 | 1652 | 1637 | 1.98 / 1036.13 | 6 | 11 |
3 | 13 | 1924.24 | 36 | 9.57 | 1611 | 555 | 2.53 / 1036.68 | 6 | 14 |
4 | 13 | 1827.16 | 36 | 9.68 | 1550 | 540 | 3.07 / 1037.23 | 6 | 17 |
5 | 13 | 1424.40 | 36 | 9.94 | 1294 | 463 | 3.54 / 1037.69 | 6 | 23 |
6 | 13 | 1117.80 | 36 | 10.16 | 1087 | 398 | 3.93 / 1038.09 | 6 | 28 |
7 | 13 | 593.72 | 36 | 10.57 | 711 | 271 | 4.20 / 1038.36 | 6 | 28 |
8 | 13 | 176.64 | 36 | 10.94 | 398 | 157 | 4.36 / 1038.51 | 6 | 20 |
9 | 13 | 48.80 | 36 | 11.05 | 306 | 122 | 4.48 / 1038.63 | 6 | 18 |
10 | 8 | 0.00 | 450 | 11.08 | 269 | 1341 | 5.82 / 1039.98 | 6 | 37 |
Average= | 6.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 93 | 11.15 | 332 | 344 | 0.34 / 1028.68 | 6 | 6 |
2 | 7 | 2001.56 | 105 | 9.63 | 1652 | 1670 | 2.01 / 1030.35 | 6 | 12 |
3 | 13 | 1922.88 | 36 | 9.82 | 1619 | 572 | 2.59 / 1030.92 | 6 | 15 |
4 | 13 | 1828.68 | 36 | 9.90 | 1558 | 555 | 3.14 / 1031.48 | 6 | 19 |
5 | 13 | 1418.20 | 36 | 10.16 | 1285 | 470 | 3.61 / 1031.95 | 6 | 24 |
6 | 13 | 911.80 | 36 | 10.46 | 950 | 358 | 3.97 / 1032.31 | 6 | 30 |
7 | 13 | 598.40 | 36 | 10.69 | 717 | 276 | 4.25 / 1032.58 | 6 | 28 |
8 | 13 | 92.48 | 36 | 11.08 | 331 | 132 | 4.38 / 1032.71 | 6 | 18 |
9 | 13 | 49.12 | 36 | 11.10 | 301 | 120 | 4.50 / 1032.83 | 6 | 18 |
10 | 8 | -0.04 | 450 | 11.14 | 263 | 1318 | 5.82 / 1034.15 | 6 | 30 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 92 | 11.17 | 336 | 345 | 0.35 / 1022.65 | 6 | 6 |
2 | 3 | 1016.64 | 1 | 10.53 | 980 | 10 | 0.36 / 1022.66 | 6 | 6 |
3 | 7 | 2001.12 | 105 | 9.76 | 1658 | 1699 | 2.05 / 1024.36 | 6 | 12 |
4 | 13 | 1920.56 | 36 | 9.97 | 1618 | 581 | 2.64 / 1024.94 | 6 | 16 |
5 | 13 | 1724.24 | 36 | 10.09 | 1492 | 542 | 3.18 / 1025.48 | 6 | 20 |
6 | 13 | 1318.52 | 36 | 10.30 | 1228 | 455 | 3.63 / 1025.94 | 6 | 26 |
7 | 13 | 1002.72 | 36 | 10.49 | 1010 | 381 | 4.01 / 1026.32 | 6 | 30 |
8 | 13 | 579.04 | 36 | 10.79 | 700 | 272 | 4.29 / 1026.59 | 6 | 27 |
9 | 13 | 146.16 | 36 | 11.08 | 374 | 149 | 4.44 / 1026.74 | 6 | 18 |
10 | 13 | 38.24 | 36 | 11.14 | 298 | 120 | 4.55 / 1026.86 | 6 | 17 |
11 | 13 | 19.28 | 36 | 11.15 | 287 | 115 | 4.67 / 1026.97 | 6 | 18 |
12 | 8 | 0.20 | 450 | 11.17 | 271 | 1362 | 6.03 / 1028.33 | 6 | 32 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 92 | 11.18 | 333 | 343 | 0.34 / 1016.79 | 6 | 6 |
2 | 3 | 1014.16 | 1 | 10.60 | 980 | 10 | 0.35 / 1016.80 | 6 | 6 |
3 | 7 | 2004.92 | 105 | 9.86 | 1655 | 1713 | 2.07 / 1018.51 | 6 | 12 |
4 | 13 | 1929.44 | 36 | 10.02 | 1624 | 586 | 2.65 / 1019.10 | 6 | 16 |
5 | 13 | 1731.80 | 36 | 10.17 | 1494 | 547 | 3.20 / 1019.65 | 6 | 20 |
6 | 13 | 1318.64 | 36 | 10.37 | 1223 | 457 | 3.66 / 1020.10 | 6 | 26 |
7 | 13 | 902.56 | 36 | 10.60 | 945 | 361 | 4.02 / 1020.46 | 6 | 29 |
8 | 13 | 489.12 | 36 | 10.89 | 631 | 247 | 4.26 / 1020.71 | 6 | 24 |
9 | 13 | 87.48 | 36 | 11.14 | 337 | 135 | 4.40 / 1020.85 | 6 | 17 |
10 | 13 | 48.76 | 36 | 11.15 | 316 | 127 | 4.53 / 1020.97 | 6 | 17 |
11 | 8 | 0.04 | 450 | 11.19 | 264 | 1329 | 5.86 / 1022.30 | 6 | 36 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 74 | 11.15 | 333 | 275 | 0.27 / 1010.55 | 6 | 6 |
2 | 10 | 1025.20 | 9 | 10.62 | 1021 | 98 | 0.37 / 1010.65 | 6 | 7 |
3 | 10 | 1055.12 | 6 | 10.58 | 1038 | 66 | 0.44 / 1010.72 | 6 | 8 |
4 | 3 | 1079.24 | 4 | 10.41 | 1090 | 45 | 0.48 / 1010.76 | 6 | 12 |
5 | 7 | 2004.24 | 105 | 9.93 | 1661 | 1732 | 2.22 / 1012.49 | 12 | 14 |
6 | 13 | 1922.24 | 36 | 10.08 | 1615 | 586 | 2.80 / 1013.08 | 6 | 17 |
7 | 13 | 1827.96 | 36 | 10.15 | 1557 | 569 | 3.37 / 1013.65 | 6 | 20 |
8 | 13 | 1302.44 | 36 | 10.41 | 1223 | 458 | 3.83 / 1014.11 | 6 | 26 |
9 | 13 | 996.20 | 36 | 10.57 | 1014 | 386 | 4.21 / 1014.49 | 6 | 30 |
10 | 13 | 474.32 | 36 | 10.91 | 625 | 245 | 4.46 / 1014.74 | 6 | 25 |
11 | 13 | 82.60 | 36 | 11.16 | 326 | 131 | 4.59 / 1014.87 | 6 | 17 |
12 | 13 | 45.36 | 36 | 11.17 | 301 | 121 | 4.71 / 1014.99 | 6 | 17 |
13 | 13 | 8.28 | 36 | 11.19 | 281 | 113 | 4.83 / 1015.10 | 6 | 18 |
14 | 8 | -0.04 | 450 | 11.19 | 267 | 1344 | 6.17 / 1016.45 | 6 | 33 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 73 | 13.93 | 342 | 348 | 0.35 / 1004.71 | 6 | 6 |
2 | 7 | 2002.84 | 106 | 9.85 | 1656 | 1729 | 2.08 / 1006.44 | 6 | 12 |
3 | 13 | 1919.20 | 36 | 10.00 | 1609 | 579 | 2.66 / 1007.02 | 6 | 16 |
4 | 13 | 1620.48 | 36 | 10.15 | 1427 | 521 | 3.18 / 1007.54 | 6 | 21 |
5 | 13 | 1316.52 | 36 | 10.30 | 1225 | 454 | 3.63 / 1008.00 | 6 | 26 |
6 | 13 | 904.68 | 36 | 10.52 | 946 | 358 | 3.99 / 1008.36 | 6 | 30 |
7 | 13 | 487.84 | 36 | 10.85 | 629 | 246 | 4.24 / 1008.60 | 6 | 25 |
8 | 13 | 81.64 | 36 | 11.11 | 325 | 130 | 4.37 / 1008.73 | 6 | 17 |
9 | 13 | 23.84 | 36 | 11.14 | 285 | 114 | 4.48 / 1008.85 | 6 | 17 |
10 | 13 | 10.72 | 36 | 11.14 | 276 | 111 | 4.59 / 1008.96 | 6 | 17 |
11 | 8 | -0.04 | 450 | 11.16 | 263 | 1321 | 5.91 / 1010.28 | 6 | 33 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 73 | 14.20 | 333 | 345 | 0.35 / 998.27 | 6 | 6 |
2 | 7 | 2001.76 | 105 | 11.36 | 1666 | 1987 | 2.33 / 1000.26 | 6 | 19 |
3 | 13 | 1904.20 | 36 | 11.92 | 1628 | 699 | 3.03 / 1000.96 | 6 | 24 |
4 | 13 | 1488.52 | 36 | 12.45 | 1364 | 611 | 3.64 / 1001.57 | 6 | 35 |
5 | 13 | 957.28 | 36 | 12.80 | 1009 | 465 | 4.11 / 1002.03 | 6 | 41 |
6 | 13 | 414.08 | 36 | 13.43 | 596 | 288 | 4.40 / 1002.32 | 6 | 33 |
7 | 13 | 52.28 | 36 | 13.94 | 319 | 160 | 4.56 / 1002.48 | 6 | 25 |
8 | 13 | 27.08 | 36 | 13.96 | 303 | 152 | 4.71 / 1002.63 | 6 | 26 |
9 | 8 | 0.12 | 450 | 13.86 | 278 | 1734 | 6.44 / 1004.37 | 6 | 50 |
Average= | 6.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 73 | 14.22 | 351 | 364 | 0.36 / 991.96 | 6 | 6 |
2 | 7 | 2001.12 | 105 | 11.67 | 1676 | 2054 | 2.42 / 994.01 | 6 | 19 |
3 | 13 | 1900.60 | 36 | 12.70 | 1641 | 750 | 3.17 / 994.76 | 6 | 29 |
4 | 13 | 1359.84 | 36 | 13.11 | 1287 | 607 | 3.78 / 995.37 | 6 | 39 |
5 | 13 | 930.56 | 36 | 13.38 | 994 | 479 | 4.25 / 995.85 | 6 | 44 |
6 | 13 | 175.92 | 36 | 14.06 | 415 | 210 | 4.46 / 996.06 | 6 | 26 |
7 | 13 | 47.80 | 36 | 14.19 | 316 | 161 | 4.63 / 996.22 | 6 | 25 |
8 | 8 | 0.08 | 450 | 14.19 | 267 | 1705 | 6.33 / 997.92 | 6 | 53 |
Average= | 6.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 72 | 14.29 | 341 | 351 | 0.35 / 985.34 | 6 | 6 |
2 | 7 | 2011.68 | 106 | 11.88 | 1682 | 2118 | 2.47 / 987.46 | 6 | 20 |
3 | 13 | 1811.84 | 36 | 12.98 | 1588 | 742 | 3.21 / 988.20 | 6 | 33 |
4 | 13 | 1384.24 | 36 | 13.25 | 1300 | 620 | 3.83 / 988.82 | 6 | 41 |
5 | 13 | 945.28 | 36 | 13.51 | 1002 | 487 | 4.32 / 989.31 | 6 | 46 |
6 | 13 | 189.56 | 36 | 14.14 | 437 | 222 | 4.54 / 989.53 | 6 | 28 |
7 | 13 | 45.24 | 36 | 14.27 | 324 | 166 | 4.71 / 989.69 | 6 | 26 |
8 | 13 | 24.24 | 36 | 14.29 | 307 | 158 | 4.87 / 989.85 | 6 | 26 |
9 | 8 | 0.00 | 450 | 14.23 | 272 | 1742 | 6.61 / 991.59 | 6 | 52 |
Average= | 6.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 72 | 14.24 | 339 | 348 | 0.35 / 978.90 | 6 | 6 |
2 | 3 | 1009.76 | 1 | 13.61 | 1015 | 14 | 0.36 / 978.91 | 6 | 6 |
3 | 7 | 2001.40 | 105 | 12.00 | 1681 | 2118 | 2.48 / 981.03 | 6 | 21 |
4 | 13 | 1901.96 | 36 | 13.01 | 1635 | 766 | 3.25 / 981.79 | 6 | 32 |
5 | 13 | 1363.72 | 36 | 13.30 | 1291 | 618 | 3.86 / 982.41 | 6 | 42 |
6 | 13 | 823.32 | 36 | 13.60 | 921 | 451 | 4.31 / 982.86 | 6 | 46 |
7 | 13 | 180.76 | 36 | 14.15 | 423 | 215 | 4.53 / 983.08 | 6 | 28 |
8 | 13 | 44.04 | 36 | 14.26 | 318 | 163 | 4.69 / 983.24 | 6 | 27 |
9 | 8 | 0.00 | 450 | 14.31 | 271 | 1745 | 6.44 / 984.99 | 6 | 54 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 72 | 14.24 | 339 | 348 | 0.35 / 972.45 | 6 | 6 |
2 | 7 | 2003.28 | 105 | 12.05 | 1679 | 2124 | 2.47 / 974.57 | 6 | 22 |
3 | 13 | 1909.12 | 36 | 13.03 | 1644 | 771 | 3.24 / 975.34 | 6 | 32 |
4 | 13 | 1265.84 | 36 | 13.33 | 1228 | 589 | 3.83 / 975.93 | 6 | 42 |
5 | 13 | 835.92 | 36 | 13.58 | 924 | 452 | 4.28 / 976.39 | 6 | 46 |
6 | 13 | 184.84 | 36 | 14.13 | 431 | 219 | 4.50 / 976.61 | 6 | 30 |
7 | 13 | 39.36 | 36 | 14.24 | 317 | 163 | 4.67 / 976.77 | 6 | 26 |
8 | 8 | 0.00 | 450 | 14.29 | 277 | 1781 | 6.45 / 978.55 | 6 | 53 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 72 | 14.28 | 353 | 363 | 0.36 / 966.11 | 6 | 6 |
2 | 7 | 2001.20 | 105 | 12.09 | 1678 | 2130 | 2.49 / 968.24 | 6 | 21 |
3 | 13 | 1799.68 | 36 | 13.09 | 1578 | 744 | 3.24 / 968.99 | 6 | 35 |
4 | 13 | 1284.36 | 36 | 13.31 | 1241 | 595 | 3.83 / 969.58 | 6 | 42 |
5 | 13 | 658.44 | 36 | 13.71 | 790 | 390 | 4.22 / 969.97 | 6 | 42 |
6 | 13 | 128.28 | 36 | 14.16 | 384 | 196 | 4.42 / 970.17 | 6 | 28 |
7 | 13 | 29.64 | 36 | 14.27 | 309 | 159 | 4.58 / 970.33 | 6 | 28 |
8 | 8 | -0.04 | 450 | 14.30 | 276 | 1776 | 6.35 / 972.10 | 6 | 53 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 72 | 14.36 | 350 | 362 | 0.36 / 959.63 | 6 | 6 |
2 | 7 | 2001.16 | 105 | 12.19 | 1682 | 2153 | 2.51 / 961.78 | 6 | 22 |
3 | 13 | 1802.64 | 36 | 13.13 | 1576 | 745 | 3.26 / 962.53 | 6 | 35 |
4 | 13 | 1268.08 | 36 | 13.34 | 1231 | 591 | 3.85 / 963.12 | 6 | 43 |
5 | 13 | 839.52 | 36 | 13.58 | 932 | 456 | 4.31 / 963.57 | 6 | 45 |
6 | 13 | 169.68 | 36 | 14.14 | 422 | 215 | 4.52 / 963.79 | 6 | 31 |
7 | 13 | 19.04 | 36 | 14.28 | 305 | 157 | 4.68 / 963.95 | 6 | 27 |
8 | 8 | 0.00 | 450 | 14.32 | 280 | 1804 | 6.48 / 965.75 | 6 | 53 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 72 | 14.31 | 355 | 366 | 0.37 / 953.19 | 6 | 6 |
2 | 7 | 2002.44 | 106 | 12.28 | 1687 | 2196 | 2.56 / 955.39 | 6 | 23 |
3 | 13 | 1901.68 | 36 | 13.14 | 1637 | 774 | 3.34 / 956.16 | 6 | 33 |
4 | 13 | 1170.64 | 36 | 13.43 | 1161 | 561 | 3.90 / 956.73 | 6 | 44 |
5 | 13 | 745.08 | 36 | 13.69 | 857 | 422 | 4.32 / 957.15 | 6 | 44 |
6 | 13 | 97.20 | 36 | 14.26 | 359 | 184 | 4.50 / 957.33 | 6 | 28 |
7 | 13 | 10.32 | 36 | 14.34 | 295 | 152 | 4.66 / 957.48 | 6 | 28 |
8 | 8 | 0.12 | 450 | 14.36 | 276 | 1784 | 6.44 / 959.27 | 6 | 58 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 72 | 14.31 | 351 | 362 | 0.36 / 946.65 | 6 | 6 |
2 | 7 | 2001.92 | 105 | 9.27 | 1633 | 1589 | 1.95 / 948.24 | 6 | 11 |
3 | 13 | 1927.76 | 36 | 12.84 | 1655 | 765 | 2.72 / 949.00 | 6 | 29 |
4 | 13 | 1628.32 | 36 | 13.10 | 1463 | 690 | 3.41 / 949.69 | 6 | 36 |
5 | 13 | 1205.44 | 36 | 13.32 | 1190 | 571 | 3.98 / 950.26 | 6 | 44 |
6 | 13 | 577.88 | 36 | 13.80 | 732 | 364 | 4.34 / 950.63 | 6 | 41 |
7 | 13 | 70.72 | 36 | 14.29 | 348 | 179 | 4.52 / 950.80 | 6 | 28 |
8 | 13 | 17.96 | 36 | 14.35 | 309 | 160 | 4.68 / 950.96 | 6 | 28 |
9 | 8 | 0.04 | 450 | 14.33 | 289 | 1864 | 6.54 / 952.83 | 6 | 55 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 72 | 14.28 | 353 | 363 | 0.36 / 940.06 | 6 | 7 |
2 | 7 | 2010.68 | 105 | 9.36 | 1641 | 1613 | 1.98 / 941.67 | 7 | 12 |
3 | 13 | 1932.40 | 36 | 12.84 | 1660 | 767 | 2.74 / 942.44 | 6 | 30 |
4 | 13 | 1732.52 | 36 | 13.04 | 1532 | 719 | 3.46 / 943.16 | 6 | 35 |
5 | 13 | 1196.76 | 36 | 13.31 | 1189 | 570 | 4.03 / 943.73 | 6 | 44 |
6 | 13 | 561.16 | 36 | 13.80 | 719 | 357 | 4.39 / 944.08 | 6 | 41 |
7 | 13 | 63.40 | 36 | 14.30 | 344 | 177 | 4.57 / 944.26 | 6 | 28 |
8 | 13 | 15.48 | 36 | 14.34 | 316 | 163 | 4.73 / 944.42 | 6 | 29 |
9 | 8 | 0.08 | 450 | 14.32 | 289 | 1862 | 6.59 / 946.29 | 6 | 54 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 72 | 14.28 | 355 | 365 | 0.36 / 933.52 | 6 | 6 |
2 | 7 | 2010.76 | 105 | 9.38 | 1640 | 1615 | 1.98 / 935.14 | 6 | 12 |
3 | 13 | 1930.56 | 36 | 12.83 | 1657 | 765 | 2.75 / 935.90 | 6 | 29 |
4 | 13 | 1730.44 | 36 | 13.03 | 1534 | 720 | 3.47 / 936.62 | 6 | 37 |
5 | 13 | 1202.32 | 36 | 13.32 | 1185 | 568 | 4.03 / 937.19 | 6 | 45 |
6 | 13 | 567.56 | 36 | 13.79 | 724 | 359 | 4.39 / 937.55 | 6 | 41 |
7 | 13 | 66.40 | 36 | 14.28 | 342 | 176 | 4.57 / 937.73 | 6 | 28 |
8 | 13 | 15.40 | 36 | 14.35 | 303 | 157 | 4.73 / 937.88 | 6 | 29 |
9 | 8 | -0.04 | 450 | 14.32 | 281 | 1811 | 6.54 / 939.69 | 6 | 58 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 72 | 14.31 | 346 | 356 | 0.36 / 926.99 | 6 | 7 |
2 | 7 | 2001.40 | 106 | 9.42 | 1632 | 1630 | 1.99 / 928.62 | 7 | 12 |
3 | 13 | 1923.36 | 36 | 12.84 | 1652 | 764 | 2.75 / 929.38 | 6 | 30 |
4 | 13 | 1616.16 | 36 | 13.08 | 1461 | 688 | 3.44 / 930.07 | 6 | 38 |
5 | 13 | 1083.28 | 36 | 13.39 | 1107 | 534 | 3.97 / 930.61 | 6 | 45 |
6 | 13 | 557.56 | 36 | 13.81 | 718 | 357 | 4.33 / 930.96 | 6 | 42 |
7 | 13 | 55.44 | 36 | 14.31 | 333 | 172 | 4.50 / 931.13 | 6 | 28 |
8 | 13 | 12.68 | 36 | 14.34 | 302 | 156 | 4.66 / 931.29 | 6 | 29 |
9 | 8 | -0.04 | 450 | 14.31 | 290 | 1867 | 6.52 / 933.16 | 6 | 59 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 72 | 14.27 | 356 | 366 | 0.37 / 920.62 | 6 | 7 |
2 | 7 | 2001.96 | 105 | 9.47 | 1634 | 1625 | 1.99 / 922.25 | 7 | 12 |
3 | 13 | 1928.04 | 36 | 12.83 | 1654 | 764 | 2.75 / 923.01 | 6 | 30 |
4 | 13 | 1631.40 | 36 | 13.08 | 1466 | 690 | 3.44 / 923.70 | 6 | 38 |
5 | 13 | 1099.44 | 36 | 13.39 | 1113 | 537 | 3.98 / 924.24 | 6 | 45 |
6 | 13 | 673.32 | 36 | 13.71 | 796 | 393 | 4.37 / 924.63 | 6 | 43 |
7 | 13 | 113.16 | 36 | 14.24 | 376 | 193 | 4.57 / 924.82 | 6 | 30 |
8 | 8 | 0.12 | 450 | 14.33 | 281 | 1812 | 6.38 / 926.63 | 6 | 52 |
Average= | 6.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 72 | 14.31 | 346 | 356 | 0.36 / 914.25 | 6 | 7 |
2 | 7 | 2011.28 | 105 | 9.49 | 1644 | 1638 | 1.99 / 915.89 | 7 | 12 |
3 | 13 | 1932.92 | 36 | 12.82 | 1657 | 765 | 2.76 / 916.66 | 6 | 29 |
4 | 13 | 1536.28 | 36 | 13.12 | 1413 | 667 | 3.43 / 917.32 | 6 | 38 |
5 | 13 | 1224.08 | 36 | 13.31 | 1200 | 575 | 4.00 / 917.90 | 6 | 44 |
6 | 13 | 580.64 | 36 | 13.77 | 737 | 365 | 4.37 / 918.27 | 6 | 42 |
7 | 13 | 72.40 | 36 | 14.30 | 346 | 178 | 4.55 / 918.44 | 6 | 30 |
8 | 8 | 0.04 | 450 | 14.33 | 281 | 1812 | 6.36 / 920.26 | 6 | 52 |
Average= | 6.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 72 | 14.28 | 356 | 366 | 0.37 / 907.69 | 6 | 7 |
2 | 7 | 2011.12 | 105 | 9.54 | 1646 | 1649 | 2.01 / 909.34 | 7 | 13 |
3 | 13 | 1933.52 | 36 | 12.82 | 1661 | 767 | 2.78 / 910.11 | 6 | 30 |
4 | 13 | 1632.84 | 36 | 13.07 | 1467 | 690 | 3.47 / 910.80 | 6 | 38 |
5 | 13 | 1092.92 | 36 | 13.38 | 1111 | 535 | 4.01 / 911.33 | 6 | 45 |
6 | 13 | 564.00 | 36 | 13.79 | 723 | 359 | 4.37 / 911.69 | 6 | 42 |
7 | 13 | 65.68 | 36 | 14.31 | 340 | 175 | 4.54 / 911.87 | 6 | 28 |
8 | 13 | 15.76 | 36 | 14.35 | 305 | 158 | 4.70 / 912.03 | 6 | 28 |
9 | 8 | 0.04 | 450 | 14.30 | 291 | 1873 | 6.57 / 913.90 | 6 | 63 |
Average= | 6.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 72 | 14.26 | 363 | 373 | 0.37 / 901.18 | 6 | 7 |
2 | 7 | 2001.52 | 105 | 9.62 | 1637 | 1654 | 2.03 / 902.83 | 6 | 13 |
3 | 13 | 1923.48 | 36 | 12.82 | 1650 | 762 | 2.79 / 903.59 | 6 | 31 |
4 | 13 | 1722.00 | 36 | 13.01 | 1530 | 717 | 3.50 / 904.31 | 6 | 35 |
5 | 13 | 1169.36 | 36 | 13.33 | 1163 | 558 | 4.06 / 904.87 | 6 | 44 |
6 | 13 | 637.52 | 36 | 13.72 | 778 | 384 | 4.45 / 905.25 | 6 | 44 |
7 | 13 | 96.56 | 36 | 14.28 | 359 | 185 | 4.63 / 905.44 | 6 | 30 |
8 | 8 | 0.20 | 450 | 14.30 | 294 | 1892 | 6.52 / 907.33 | 6 | 45 |
Average= | 6.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 72 | 14.25 | 356 | 365 | 0.37 / 894.74 | 6 | 7 |
2 | 7 | 2011.16 | 105 | 9.60 | 1642 | 1655 | 2.02 / 896.40 | 7 | 12 |
3 | 13 | 1933.72 | 36 | 12.81 | 1663 | 767 | 2.79 / 897.17 | 6 | 29 |
4 | 13 | 1637.76 | 36 | 13.07 | 1477 | 695 | 3.48 / 897.86 | 6 | 36 |
5 | 13 | 1017.32 | 36 | 13.42 | 1065 | 515 | 4.00 / 898.38 | 6 | 45 |
6 | 13 | 592.68 | 36 | 13.78 | 739 | 367 | 4.36 / 898.74 | 6 | 42 |
7 | 13 | 70.24 | 36 | 14.29 | 346 | 178 | 4.54 / 898.92 | 6 | 30 |
8 | 8 | 0.16 | 450 | 14.29 | 293 | 1884 | 6.43 / 900.80 | 6 | 54 |
Average= | 6.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 72 | 14.28 | 353 | 363 | 0.36 / 888.32 | 6 | 7 |
2 | 7 | 2002.72 | 105 | 9.70 | 1636 | 1666 | 2.03 / 889.98 | 7 | 13 |
3 | 13 | 1926.08 | 36 | 12.81 | 1649 | 760 | 2.79 / 890.74 | 6 | 30 |
4 | 13 | 1725.28 | 36 | 13.01 | 1533 | 718 | 3.51 / 891.46 | 6 | 37 |
5 | 13 | 1186.04 | 36 | 13.33 | 1171 | 562 | 4.07 / 892.02 | 6 | 44 |
6 | 13 | 549.64 | 36 | 13.82 | 707 | 352 | 4.42 / 892.38 | 6 | 41 |
7 | 13 | 114.32 | 36 | 14.27 | 372 | 191 | 4.61 / 892.57 | 6 | 30 |
8 | 8 | 0.08 | 450 | 14.32 | 281 | 1811 | 6.42 / 894.38 | 6 | 58 |
Average= | 6.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 72 | 14.25 | 363 | 372 | 0.37 / 881.80 | 6 | 7 |
2 | 7 | 2012.72 | 105 | 9.76 | 1646 | 1687 | 2.06 / 883.49 | 6 | 13 |
3 | 13 | 1931.12 | 36 | 12.80 | 1656 | 763 | 2.82 / 884.25 | 6 | 30 |
4 | 13 | 1633.16 | 36 | 13.06 | 1473 | 693 | 3.51 / 884.95 | 6 | 37 |
5 | 13 | 1104.76 | 36 | 13.37 | 1119 | 539 | 4.05 / 885.49 | 6 | 44 |
6 | 13 | 675.44 | 36 | 13.69 | 808 | 398 | 4.45 / 885.88 | 6 | 44 |
7 | 13 | 115.84 | 36 | 14.27 | 374 | 192 | 4.64 / 886.08 | 6 | 31 |
8 | 8 | 0.00 | 450 | 14.30 | 292 | 1879 | 6.52 / 887.96 | 6 | 56 |
Average= | 6.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 72 | 14.26 | 355 | 364 | 0.36 / 875.31 | 6 | 7 |
2 | 7 | 2011.04 | 105 | 9.79 | 1648 | 1694 | 2.06 / 877.01 | 7 | 13 |
3 | 13 | 1932.00 | 36 | 12.79 | 1656 | 762 | 2.82 / 877.77 | 6 | 30 |
4 | 13 | 1735.20 | 36 | 13.00 | 1537 | 719 | 3.54 / 878.49 | 6 | 36 |
5 | 13 | 1087.28 | 36 | 13.39 | 1102 | 531 | 4.07 / 879.02 | 6 | 45 |
6 | 13 | 657.36 | 36 | 13.69 | 796 | 392 | 4.46 / 879.41 | 6 | 45 |
7 | 13 | 52.36 | 36 | 14.32 | 332 | 171 | 4.64 / 879.59 | 6 | 29 |
8 | 8 | 0.04 | 450 | 14.30 | 287 | 1847 | 6.48 / 881.43 | 6 | 56 |
Average= | 6.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 72 | 14.25 | 360 | 369 | 0.37 / 868.94 | 6 | 7 |
2 | 7 | 2004.08 | 105 | 9.85 | 1647 | 1703 | 2.07 / 870.64 | 7 | 14 |
3 | 13 | 1926.88 | 36 | 12.79 | 1654 | 762 | 2.83 / 871.40 | 6 | 30 |
4 | 13 | 1525.00 | 36 | 13.12 | 1404 | 663 | 3.50 / 872.06 | 6 | 38 |
5 | 13 | 1105.44 | 36 | 13.35 | 1121 | 539 | 4.04 / 872.60 | 6 | 46 |
6 | 13 | 465.76 | 36 | 13.88 | 650 | 325 | 4.36 / 872.93 | 6 | 40 |
7 | 13 | 66.20 | 36 | 14.31 | 345 | 178 | 4.54 / 873.10 | 6 | 30 |
8 | 8 | 0.24 | 450 | 14.29 | 287 | 1846 | 6.38 / 874.95 | 6 | 59 |
Average= | 6.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 72 | 14.25 | 367 | 377 | 0.38 / 862.41 | 6 | 7 |
2 | 7 | 2009.20 | 105 | 9.89 | 1651 | 1714 | 2.09 / 864.12 | 7 | 14 |
3 | 13 | 1926.32 | 36 | 12.78 | 1659 | 763 | 2.85 / 864.89 | 6 | 30 |
4 | 13 | 1625.44 | 36 | 13.04 | 1476 | 693 | 3.55 / 865.58 | 6 | 37 |
5 | 13 | 1097.84 | 36 | 13.33 | 1131 | 543 | 4.09 / 866.12 | 6 | 45 |
6 | 13 | 570.48 | 36 | 13.77 | 734 | 364 | 4.45 / 866.49 | 6 | 44 |
7 | 13 | 64.56 | 36 | 14.30 | 350 | 180 | 4.63 / 866.67 | 6 | 30 |
8 | 8 | -0.08 | 450 | 14.27 | 296 | 1901 | 6.53 / 868.57 | 6 | 54 |
Average= | 6.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 72 | 14.26 | 360 | 370 | 0.37 / 855.92 | 6 | 7 |
2 | 7 | 2013.16 | 106 | 9.91 | 1651 | 1734 | 2.10 / 857.65 | 7 | 14 |
3 | 13 | 1927.88 | 36 | 12.77 | 1661 | 764 | 2.87 / 858.42 | 6 | 31 |
4 | 13 | 1619.96 | 36 | 13.06 | 1464 | 688 | 3.56 / 859.10 | 6 | 38 |
5 | 13 | 990.92 | 36 | 13.42 | 1045 | 505 | 4.06 / 859.61 | 6 | 46 |
6 | 13 | 468.04 | 36 | 13.86 | 655 | 327 | 4.39 / 859.94 | 6 | 40 |
7 | 13 | 67.68 | 36 | 14.29 | 355 | 183 | 4.57 / 860.12 | 6 | 31 |
8 | 8 | 0.12 | 450 | 14.27 | 298 | 1914 | 6.48 / 862.03 | 6 | 49 |
Average= | 6.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 72 | 14.24 | 364 | 373 | 0.37 / 849.47 | 6 | 8 |
2 | 7 | 2002.96 | 106 | 9.95 | 1642 | 1732 | 2.11 / 851.20 | 8 | 15 |
3 | 13 | 1925.88 | 36 | 12.78 | 1653 | 761 | 2.87 / 851.96 | 6 | 31 |
4 | 13 | 1521.32 | 36 | 13.10 | 1396 | 658 | 3.52 / 852.62 | 6 | 40 |
5 | 13 | 999.04 | 36 | 13.41 | 1051 | 507 | 4.03 / 853.13 | 6 | 46 |
6 | 13 | 471.32 | 36 | 13.86 | 664 | 331 | 4.36 / 853.46 | 6 | 41 |
7 | 13 | 66.84 | 36 | 14.29 | 354 | 182 | 4.54 / 853.64 | 6 | 31 |
8 | 8 | 0.16 | 450 | 14.26 | 297 | 1906 | 6.45 / 855.55 | 6 | 51 |
Average= | 6.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 72 | 14.26 | 359 | 369 | 0.37 / 842.92 | 6 | 7 |
2 | 7 | 2013.52 | 105 | 10.00 | 1650 | 1732 | 2.10 / 844.65 | 7 | 14 |
3 | 13 | 1932.24 | 36 | 12.74 | 1665 | 764 | 2.86 / 845.42 | 6 | 30 |
4 | 13 | 1728.52 | 36 | 12.96 | 1537 | 717 | 3.58 / 846.13 | 6 | 36 |
5 | 13 | 1083.16 | 36 | 13.36 | 1109 | 533 | 4.12 / 846.67 | 6 | 45 |
6 | 13 | 548.36 | 36 | 13.81 | 712 | 354 | 4.47 / 847.02 | 6 | 42 |
7 | 13 | 52.60 | 36 | 14.32 | 329 | 170 | 4.64 / 847.19 | 6 | 29 |
8 | 8 | 0.04 | 450 | 14.26 | 297 | 1906 | 6.54 / 849.10 | 6 | 55 |
Average= | 6.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 72 | 14.28 | 350 | 360 | 0.36 / 836.53 | 6 | 7 |
2 | 7 | 2002.24 | 105 | 10.03 | 1649 | 1737 | 2.10 / 838.26 | 7 | 14 |
3 | 13 | 1918.44 | 36 | 12.76 | 1652 | 759 | 2.86 / 839.02 | 6 | 30 |
4 | 13 | 1612.24 | 36 | 13.05 | 1457 | 684 | 3.54 / 839.71 | 6 | 37 |
5 | 13 | 971.72 | 36 | 13.41 | 1031 | 498 | 4.04 / 840.21 | 6 | 45 |
6 | 13 | 555.64 | 36 | 13.80 | 715 | 355 | 4.39 / 840.56 | 6 | 41 |
7 | 13 | 55.96 | 36 | 14.32 | 333 | 172 | 4.56 / 840.73 | 6 | 29 |
8 | 8 | -0.12 | 450 | 14.29 | 283 | 1820 | 6.38 / 842.55 | 6 | 57 |
Average= | 6.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 72 | 14.26 | 365 | 375 | 0.37 / 830.15 | 6 | 7 |
2 | 7 | 2002.20 | 105 | 10.11 | 1651 | 1753 | 2.13 / 831.90 | 7 | 15 |
3 | 13 | 1923.96 | 36 | 12.75 | 1649 | 757 | 2.88 / 832.66 | 6 | 31 |
4 | 13 | 1437.28 | 36 | 13.11 | 1353 | 639 | 3.52 / 833.30 | 6 | 40 |
5 | 13 | 1031.88 | 36 | 13.38 | 1071 | 516 | 4.04 / 833.81 | 6 | 45 |
6 | 13 | 598.64 | 36 | 13.74 | 748 | 370 | 4.41 / 834.18 | 6 | 44 |
7 | 13 | 74.68 | 36 | 14.30 | 347 | 179 | 4.59 / 834.36 | 6 | 30 |
8 | 8 | 0.24 | 450 | 14.28 | 281 | 1806 | 6.39 / 836.17 | 6 | 63 |
Average= | 6.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 72 | 14.26 | 344 | 353 | 0.35 / 823.72 | 6 | 7 |
2 | 7 | 2009.68 | 105 | 10.15 | 1653 | 1762 | 2.11 / 825.48 | 7 | 15 |
3 | 13 | 1923.20 | 36 | 12.76 | 1649 | 757 | 2.87 / 826.24 | 6 | 30 |
4 | 13 | 1622.36 | 36 | 13.03 | 1467 | 688 | 3.56 / 826.92 | 6 | 38 |
5 | 13 | 1084.44 | 36 | 13.34 | 1109 | 533 | 4.09 / 827.46 | 6 | 46 |
6 | 13 | 352.40 | 36 | 14.01 | 557 | 281 | 4.37 / 827.74 | 6 | 35 |
7 | 13 | 70.16 | 36 | 14.32 | 340 | 175 | 4.55 / 827.91 | 6 | 30 |
8 | 8 | 0.00 | 450 | 14.27 | 290 | 1862 | 6.41 / 829.78 | 6 | 48 |
Average= | 6.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 72 | 14.20 | 370 | 378 | 0.38 / 817.13 | 6 | 7 |
2 | 7 | 2001.16 | 105 | 10.16 | 1647 | 1757 | 2.14 / 818.89 | 7 | 15 |
3 | 13 | 1918.64 | 36 | 12.72 | 1651 | 756 | 2.89 / 819.64 | 6 | 31 |
4 | 13 | 1721.56 | 36 | 12.95 | 1532 | 714 | 3.61 / 820.36 | 6 | 37 |
5 | 13 | 1070.92 | 36 | 13.35 | 1099 | 528 | 4.13 / 820.88 | 6 | 46 |
6 | 13 | 537.84 | 36 | 13.78 | 699 | 347 | 4.48 / 821.23 | 6 | 43 |
7 | 13 | 55.40 | 36 | 14.31 | 334 | 172 | 4.65 / 821.40 | 6 | 30 |
8 | 13 | 33.60 | 36 | 14.31 | 316 | 163 | 4.82 / 821.57 | 6 | 31 |
9 | 8 | 0.00 | 450 | 14.27 | 280 | 1798 | 6.61 / 823.36 | 6 | 58 |
Average= | 6.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 72 | 14.28 | 355 | 365 | 0.36 / 810.64 | 6 | 7 |
2 | 7 | 2013.64 | 105 | 10.15 | 1651 | 1760 | 2.12 / 812.40 | 7 | 15 |
3 | 13 | 1931.36 | 36 | 12.74 | 1648 | 756 | 2.88 / 813.16 | 6 | 30 |
4 | 13 | 1526.64 | 36 | 13.06 | 1404 | 660 | 3.54 / 813.82 | 6 | 39 |
5 | 13 | 1100.92 | 36 | 13.33 | 1118 | 537 | 4.08 / 814.36 | 6 | 45 |
6 | 13 | 563.04 | 36 | 13.77 | 720 | 357 | 4.43 / 814.71 | 6 | 43 |
7 | 13 | 57.36 | 36 | 14.31 | 343 | 177 | 4.61 / 814.89 | 6 | 30 |
8 | 8 | 0.12 | 450 | 14.26 | 290 | 1861 | 6.47 / 816.75 | 6 | 51 |
Average= | 6.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 72 | 14.30 | 352 | 362 | 0.36 / 804.14 | 6 | 7 |
2 | 7 | 2004.60 | 105 | 10.19 | 1651 | 1766 | 2.13 / 805.90 | 7 | 15 |
3 | 13 | 1923.68 | 36 | 12.73 | 1651 | 757 | 2.89 / 806.66 | 6 | 30 |
4 | 13 | 1610.92 | 36 | 13.02 | 1456 | 682 | 3.57 / 807.34 | 6 | 38 |
5 | 13 | 1069.72 | 36 | 13.35 | 1101 | 529 | 4.10 / 807.87 | 6 | 45 |
6 | 13 | 529.76 | 36 | 13.82 | 697 | 347 | 4.44 / 808.22 | 6 | 41 |
7 | 13 | 95.92 | 36 | 14.29 | 370 | 190 | 4.63 / 808.41 | 6 | 29 |
8 | 8 | 0.00 | 450 | 14.28 | 291 | 1870 | 6.50 / 810.28 | 6 | 49 |
Average= | 6.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 71 | 14.29 | 352 | 357 | 0.36 / 797.64 | 6 | 7 |
2 | 3 | 1014.04 | 1 | 12.13 | 1012 | 12 | 0.37 / 797.66 | 6 | 6 |
3 | 7 | 2010.96 | 105 | 10.24 | 1656 | 1781 | 2.15 / 799.44 | 6 | 14 |
4 | 13 | 1924.40 | 36 | 12.73 | 1654 | 758 | 2.91 / 800.19 | 6 | 29 |
5 | 13 | 1724.44 | 36 | 12.97 | 1529 | 714 | 3.62 / 800.91 | 6 | 35 |
6 | 13 | 1078.64 | 36 | 13.35 | 1098 | 528 | 4.15 / 801.44 | 6 | 44 |
7 | 13 | 444.36 | 36 | 13.92 | 626 | 314 | 4.46 / 801.75 | 6 | 37 |
8 | 13 | 64.24 | 36 | 14.33 | 334 | 172 | 4.64 / 801.92 | 6 | 28 |
9 | 8 | 0.00 | 450 | 14.29 | 288 | 1852 | 6.49 / 803.77 | 6 | 54 |
Average= | 6.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 70 | 14.32 | 348 | 349 | 0.35 / 791.04 | 6 | 6 |
2 | 3 | 1020.88 | 1 | 12.38 | 1020 | 13 | 0.36 / 791.05 | 6 | 6 |
3 | 7 | 2001.92 | 105 | 10.35 | 1651 | 1794 | 2.16 / 792.84 | 6 | 14 |
4 | 13 | 1917.52 | 36 | 12.75 | 1648 | 756 | 2.91 / 793.60 | 6 | 29 |
5 | 13 | 1499.76 | 36 | 13.09 | 1381 | 651 | 3.56 / 794.25 | 6 | 37 |
6 | 13 | 1072.16 | 36 | 13.35 | 1094 | 526 | 4.09 / 794.78 | 6 | 45 |
7 | 13 | 526.80 | 36 | 13.84 | 684 | 341 | 4.43 / 795.12 | 6 | 39 |
8 | 13 | 50.48 | 36 | 14.33 | 333 | 172 | 4.60 / 795.29 | 6 | 28 |
9 | 13 | 26.76 | 36 | 14.32 | 313 | 161 | 4.76 / 795.45 | 6 | 29 |
10 | 8 | 0.00 | 450 | 14.28 | 286 | 1838 | 6.60 / 797.29 | 6 | 57 |
Average= | 6.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 68 | 14.27 | 351 | 341 | 0.34 / 784.25 | 6 | 6 |
2 | 3 | 1033.44 | 2 | 12.38 | 1052 | 26 | 0.37 / 784.28 | 6 | 11 |
3 | 7 | 2006.64 | 105 | 10.45 | 1658 | 1819 | 2.19 / 786.10 | 11 | 15 |
4 | 13 | 1933.60 | 36 | 12.72 | 1654 | 757 | 2.94 / 786.86 | 6 | 29 |
5 | 13 | 1834.80 | 36 | 12.87 | 1593 | 738 | 3.68 / 787.59 | 6 | 34 |
6 | 13 | 1262.36 | 36 | 13.22 | 1230 | 585 | 4.27 / 788.18 | 6 | 44 |
7 | 13 | 396.72 | 36 | 13.96 | 594 | 299 | 4.57 / 788.48 | 6 | 35 |
8 | 13 | 85.44 | 36 | 14.30 | 352 | 181 | 4.75 / 788.66 | 6 | 29 |
9 | 13 | 43.60 | 36 | 14.32 | 329 | 170 | 4.92 / 788.83 | 6 | 29 |
10 | 8 | 0.04 | 450 | 14.29 | 289 | 1858 | 6.77 / 790.69 | 6 | 58 |
Average= | 6.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 71 | 14.29 | 349 | 354 | 0.35 / 777.77 | 6 | 6 |
2 | 3 | 966.68 | -1 | 14.29 | 349 | 0 | 0.00 / 777.77 | 6 | 6 |
3 | 7 | 2002.36 | 105 | 10.49 | 1652 | 1820 | 2.17 / 779.59 | 6 | 16 |
4 | 13 | 1903.60 | 36 | 12.71 | 1634 | 748 | 2.92 / 780.34 | 6 | 31 |
5 | 13 | 1380.20 | 36 | 13.13 | 1307 | 618 | 3.54 / 780.95 | 6 | 41 |
6 | 13 | 963.32 | 36 | 13.39 | 1032 | 497 | 4.04 / 781.45 | 6 | 46 |
7 | 13 | 431.60 | 36 | 13.89 | 624 | 312 | 4.35 / 781.76 | 6 | 40 |
8 | 13 | 46.92 | 36 | 14.31 | 341 | 176 | 4.52 / 781.94 | 6 | 30 |
9 | 13 | 23.56 | 36 | 14.28 | 316 | 162 | 4.69 / 782.10 | 6 | 32 |
10 | 8 | 0.04 | 450 | 14.26 | 282 | 1810 | 6.50 / 783.91 | 6 | 56 |
Average= | 6.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 71 | 14.29 | 362 | 367 | 0.37 / 771.15 | 6 | 6 |
2 | 7 | 2001.12 | 105 | 10.43 | 1660 | 1818 | 2.19 / 772.97 | 6 | 16 |
3 | 13 | 1911.88 | 36 | 12.71 | 1641 | 751 | 2.94 / 773.72 | 6 | 30 |
4 | 13 | 1599.44 | 36 | 13.00 | 1456 | 681 | 3.62 / 774.40 | 6 | 38 |
5 | 13 | 1056.12 | 36 | 13.34 | 1090 | 523 | 4.14 / 774.92 | 6 | 46 |
6 | 13 | 408.88 | 36 | 13.93 | 604 | 303 | 4.44 / 775.23 | 6 | 38 |
7 | 13 | 50.08 | 36 | 14.33 | 329 | 170 | 4.61 / 775.40 | 6 | 30 |
8 | 13 | 26.24 | 36 | 14.29 | 322 | 166 | 4.78 / 775.56 | 6 | 30 |
9 | 8 | 0.00 | 450 | 14.26 | 289 | 1855 | 6.63 / 777.42 | 6 | 50 |
Average= | 6.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 71 | 14.32 | 347 | 353 | 0.35 / 764.54 | 6 | 6 |
2 | 7 | 2012.56 | 105 | 10.42 | 1665 | 1822 | 2.17 / 766.36 | 6 | 15 |
3 | 13 | 1927.08 | 36 | 12.70 | 1655 | 757 | 2.93 / 767.11 | 6 | 30 |
4 | 13 | 1510.48 | 36 | 13.07 | 1389 | 654 | 3.58 / 767.77 | 6 | 38 |
5 | 13 | 978.88 | 36 | 13.40 | 1035 | 499 | 4.08 / 768.27 | 6 | 46 |
6 | 13 | 342.92 | 36 | 14.00 | 557 | 281 | 4.36 / 768.55 | 6 | 36 |
7 | 13 | 57.36 | 36 | 14.31 | 341 | 176 | 4.54 / 768.72 | 6 | 31 |
8 | 13 | 29.16 | 36 | 14.29 | 327 | 168 | 4.71 / 768.89 | 6 | 31 |
9 | 8 | 0.00 | 450 | 14.24 | 295 | 1890 | 6.60 / 770.78 | 6 | 66 |
Average= | 6.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 71 | 14.29 | 352 | 357 | 0.36 / 757.98 | 6 | 6 |
2 | 7 | 2010.36 | 105 | 10.43 | 1659 | 1817 | 2.17 / 759.79 | 6 | 16 |
3 | 13 | 1921.52 | 36 | 12.69 | 1661 | 759 | 2.93 / 760.55 | 6 | 29 |
4 | 13 | 1514.08 | 36 | 13.06 | 1399 | 658 | 3.59 / 761.21 | 6 | 39 |
5 | 13 | 893.76 | 36 | 13.46 | 977 | 473 | 4.06 / 761.68 | 6 | 46 |
6 | 13 | 366.24 | 36 | 13.98 | 575 | 289 | 4.35 / 761.97 | 6 | 37 |
7 | 13 | 35.12 | 36 | 14.33 | 328 | 169 | 4.52 / 762.14 | 6 | 31 |
8 | 13 | 19.24 | 36 | 14.28 | 318 | 163 | 4.69 / 762.30 | 6 | 32 |
9 | 8 | -0.08 | 450 | 14.25 | 293 | 1879 | 6.56 / 764.18 | 6 | 64 |
Average= | 6.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 71 | 14.28 | 348 | 353 | 0.35 / 751.33 | 6 | 6 |
2 | 7 | 2001.48 | 105 | 10.28 | 1652 | 1783 | 2.14 / 753.11 | 6 | 15 |
3 | 13 | 1915.76 | 36 | 12.68 | 1641 | 749 | 2.89 / 753.86 | 6 | 29 |
4 | 13 | 1604.56 | 36 | 13.00 | 1456 | 681 | 3.57 / 754.55 | 6 | 36 |
5 | 13 | 1065.96 | 36 | 13.35 | 1099 | 528 | 4.09 / 755.07 | 6 | 45 |
6 | 13 | 426.32 | 36 | 13.93 | 617 | 309 | 4.40 / 755.38 | 6 | 39 |
7 | 13 | 47.36 | 36 | 14.32 | 343 | 177 | 4.58 / 755.56 | 6 | 30 |
8 | 13 | 25.56 | 36 | 14.29 | 327 | 168 | 4.75 / 755.73 | 6 | 32 |
9 | 8 | -0.08 | 450 | 14.24 | 295 | 1890 | 6.64 / 757.62 | 6 | 52 |
Average= | 6.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 71 | 14.30 | 349 | 354 | 0.35 / 744.75 | 6 | 6 |
2 | 7 | 2001.96 | 105 | 10.62 | 1661 | 1852 | 2.21 / 746.60 | 6 | 17 |
3 | 13 | 1918.00 | 36 | 12.66 | 1648 | 751 | 2.96 / 747.35 | 6 | 31 |
4 | 13 | 1511.28 | 36 | 13.02 | 1391 | 652 | 3.61 / 748.01 | 6 | 39 |
5 | 13 | 975.36 | 36 | 13.38 | 1033 | 498 | 4.11 / 748.50 | 6 | 47 |
6 | 13 | 337.48 | 36 | 13.98 | 553 | 278 | 4.39 / 748.78 | 6 | 36 |
7 | 13 | 28.60 | 36 | 14.34 | 318 | 164 | 4.55 / 748.95 | 6 | 30 |
8 | 13 | 16.20 | 36 | 14.26 | 308 | 158 | 4.71 / 749.11 | 6 | 31 |
9 | 8 | -0.08 | 450 | 14.21 | 293 | 1874 | 6.58 / 750.98 | 6 | 61 |
Average= | 6.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 71 | 14.31 | 354 | 360 | 0.36 / 738.21 | 6 | 7 |
2 | 7 | 2008.48 | 106 | 10.66 | 1661 | 1877 | 2.24 / 740.08 | 7 | 17 |
3 | 13 | 1916.24 | 36 | 12.66 | 1643 | 749 | 2.99 / 740.83 | 6 | 30 |
4 | 13 | 1508.28 | 36 | 13.02 | 1390 | 652 | 3.64 / 741.48 | 6 | 39 |
5 | 13 | 967.92 | 36 | 13.36 | 1028 | 494 | 4.13 / 741.98 | 6 | 46 |
6 | 13 | 337.08 | 36 | 14.00 | 547 | 276 | 4.41 / 742.25 | 6 | 35 |
7 | 13 | 53.20 | 36 | 14.31 | 333 | 172 | 4.58 / 742.43 | 6 | 31 |
8 | 13 | 27.64 | 36 | 14.30 | 313 | 161 | 4.74 / 742.59 | 6 | 31 |
9 | 8 | -0.08 | 450 | 14.26 | 282 | 1810 | 6.55 / 744.40 | 6 | 55 |
Average= | 6.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 71 | 14.31 | 350 | 356 | 0.36 / 731.61 | 6 | 6 |
2 | 7 | 2008.92 | 105 | 10.70 | 1667 | 1873 | 2.23 / 733.49 | 6 | 18 |
3 | 13 | 1926.84 | 36 | 12.65 | 1655 | 754 | 2.98 / 734.24 | 6 | 30 |
4 | 13 | 1416.40 | 36 | 13.06 | 1335 | 628 | 3.61 / 734.87 | 6 | 40 |
5 | 13 | 993.04 | 36 | 13.36 | 1043 | 502 | 4.11 / 735.37 | 6 | 46 |
6 | 13 | 351.68 | 36 | 13.98 | 558 | 281 | 4.39 / 735.65 | 6 | 37 |
7 | 13 | 33.80 | 36 | 14.33 | 318 | 164 | 4.56 / 735.81 | 6 | 30 |
8 | 13 | 19.76 | 36 | 14.26 | 319 | 164 | 4.72 / 735.98 | 6 | 31 |
9 | 8 | -0.04 | 450 | 14.24 | 292 | 1871 | 6.59 / 737.85 | 6 | 65 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 71 | 14.32 | 355 | 361 | 0.36 / 725.01 | 6 | 7 |
2 | 7 | 2008.00 | 105 | 10.72 | 1669 | 1879 | 2.24 / 726.89 | 7 | 18 |
3 | 13 | 1910.68 | 36 | 12.65 | 1645 | 749 | 2.99 / 727.64 | 6 | 31 |
4 | 13 | 1485.88 | 36 | 13.01 | 1382 | 647 | 3.64 / 728.29 | 6 | 40 |
5 | 13 | 1054.72 | 36 | 13.30 | 1097 | 525 | 4.16 / 728.81 | 6 | 46 |
6 | 13 | 400.52 | 36 | 13.91 | 601 | 301 | 4.46 / 729.11 | 6 | 39 |
7 | 13 | 43.52 | 36 | 14.32 | 329 | 170 | 4.63 / 729.28 | 6 | 31 |
8 | 13 | 9.08 | 36 | 14.33 | 301 | 155 | 4.79 / 729.44 | 6 | 33 |
9 | 8 | -0.04 | 450 | 14.24 | 284 | 1820 | 6.61 / 731.26 | 6 | 64 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 71 | 14.32 | 347 | 353 | 0.35 / 718.44 | 6 | 6 |
2 | 7 | 2005.76 | 105 | 10.77 | 1667 | 1885 | 2.24 / 720.33 | 6 | 18 |
3 | 13 | 1912.64 | 36 | 12.64 | 1650 | 751 | 2.99 / 721.08 | 6 | 31 |
4 | 13 | 1603.04 | 36 | 12.96 | 1448 | 676 | 3.66 / 721.76 | 6 | 38 |
5 | 13 | 949.36 | 36 | 13.39 | 1014 | 489 | 4.15 / 722.25 | 6 | 46 |
6 | 13 | 321.40 | 36 | 14.01 | 539 | 272 | 4.42 / 722.52 | 6 | 35 |
7 | 13 | 46.64 | 36 | 14.32 | 330 | 170 | 4.60 / 722.69 | 6 | 31 |
8 | 13 | 11.24 | 36 | 14.33 | 302 | 156 | 4.75 / 722.84 | 6 | 31 |
9 | 8 | 0.08 | 450 | 14.24 | 282 | 1807 | 6.56 / 724.65 | 6 | 61 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 71 | 14.30 | 353 | 358 | 0.36 / 711.87 | 6 | 7 |
2 | 7 | 2001.44 | 105 | 10.76 | 1662 | 1878 | 2.24 / 713.74 | 7 | 19 |
3 | 13 | 1909.28 | 36 | 12.63 | 1642 | 747 | 2.98 / 714.49 | 6 | 31 |
4 | 13 | 1495.36 | 36 | 12.99 | 1386 | 648 | 3.63 / 715.14 | 6 | 39 |
5 | 13 | 961.72 | 36 | 13.36 | 1025 | 493 | 4.12 / 715.63 | 6 | 46 |
6 | 13 | 426.80 | 36 | 13.89 | 620 | 310 | 4.43 / 715.94 | 6 | 39 |
7 | 13 | 40.76 | 36 | 14.32 | 329 | 170 | 4.60 / 716.11 | 6 | 31 |
8 | 13 | 7.40 | 36 | 14.32 | 303 | 156 | 4.76 / 716.27 | 6 | 31 |
9 | 8 | -0.04 | 450 | 14.22 | 285 | 1824 | 6.58 / 718.09 | 6 | 60 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 71 | 14.33 | 356 | 362 | 0.36 / 705.31 | 6 | 7 |
2 | 7 | 2001.76 | 105 | 10.80 | 1658 | 1880 | 2.24 / 707.19 | 6 | 19 |
3 | 13 | 1914.96 | 36 | 12.64 | 1639 | 746 | 2.99 / 707.94 | 6 | 31 |
4 | 13 | 1415.32 | 36 | 13.06 | 1330 | 625 | 3.61 / 708.57 | 6 | 39 |
5 | 13 | 993.60 | 36 | 13.37 | 1043 | 502 | 4.12 / 709.07 | 6 | 46 |
6 | 13 | 450.52 | 36 | 13.88 | 630 | 315 | 4.43 / 709.38 | 6 | 40 |
7 | 13 | 25.08 | 36 | 14.34 | 312 | 161 | 4.59 / 709.54 | 6 | 31 |
8 | 13 | 14.20 | 36 | 14.27 | 300 | 154 | 4.75 / 709.70 | 6 | 30 |
9 | 8 | 0.04 | 450 | 14.22 | 283 | 1811 | 6.56 / 711.51 | 6 | 59 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 71 | 14.34 | 357 | 363 | 0.36 / 698.84 | 6 | 7 |
2 | 7 | 2012.00 | 105 | 10.81 | 1666 | 1891 | 2.25 / 700.73 | 6 | 17 |
3 | 13 | 1916.08 | 36 | 12.62 | 1648 | 749 | 3.00 / 701.48 | 6 | 31 |
4 | 13 | 1488.96 | 36 | 13.03 | 1378 | 646 | 3.65 / 702.13 | 6 | 40 |
5 | 13 | 956.28 | 36 | 13.38 | 1017 | 490 | 4.14 / 702.62 | 6 | 45 |
6 | 13 | 421.64 | 36 | 13.94 | 605 | 304 | 4.44 / 702.92 | 6 | 36 |
7 | 13 | 47.24 | 36 | 14.35 | 325 | 168 | 4.61 / 703.09 | 6 | 28 |
8 | 8 | 0.00 | 450 | 14.26 | 290 | 1861 | 6.47 / 704.95 | 6 | 54 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 71 | 14.35 | 345 | 352 | 0.35 / 692.35 | 6 | 7 |
2 | 7 | 2010.44 | 105 | 10.80 | 1669 | 1893 | 2.24 / 694.24 | 7 | 18 |
3 | 13 | 1917.28 | 36 | 12.61 | 1644 | 746 | 2.99 / 694.99 | 6 | 30 |
4 | 13 | 1493.72 | 36 | 13.01 | 1380 | 646 | 3.64 / 695.63 | 6 | 39 |
5 | 13 | 963.08 | 36 | 13.39 | 1018 | 491 | 4.13 / 696.12 | 6 | 44 |
6 | 13 | 435.08 | 36 | 13.92 | 620 | 311 | 4.44 / 696.44 | 6 | 37 |
7 | 13 | 46.20 | 36 | 14.34 | 334 | 172 | 4.61 / 696.61 | 6 | 30 |
8 | 8 | 0.12 | 450 | 14.25 | 292 | 1872 | 6.48 / 698.48 | 6 | 53 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 71 | 14.29 | 362 | 367 | 0.37 / 685.91 | 6 | 7 |
2 | 3 | 1011.12 | 1 | 10.68 | 1006 | 11 | 0.38 / 685.92 | 6 | 6 |
3 | 7 | 2011.92 | 106 | 10.90 | 1668 | 1927 | 2.31 / 687.85 | 6 | 19 |
4 | 13 | 1918.12 | 36 | 12.62 | 1639 | 745 | 3.05 / 688.59 | 6 | 32 |
5 | 13 | 1398.56 | 36 | 13.07 | 1315 | 619 | 3.67 / 689.21 | 6 | 40 |
6 | 13 | 885.60 | 36 | 13.44 | 965 | 467 | 4.14 / 689.68 | 6 | 45 |
7 | 13 | 365.68 | 36 | 14.01 | 567 | 286 | 4.42 / 689.96 | 6 | 35 |
8 | 13 | 33.32 | 36 | 14.36 | 325 | 168 | 4.59 / 690.13 | 6 | 28 |
9 | 8 | 0.08 | 450 | 14.26 | 291 | 1867 | 6.46 / 692.00 | 6 | 56 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 70 | 14.31 | 344 | 345 | 0.34 / 679.43 | 6 | 7 |
2 | 7 | 2005.20 | 105 | 10.95 | 1665 | 1914 | 2.26 / 681.35 | 6 | 19 |
3 | 13 | 1919.60 | 36 | 12.63 | 1646 | 748 | 3.01 / 682.10 | 6 | 30 |
4 | 13 | 1404.44 | 36 | 13.07 | 1319 | 621 | 3.63 / 682.72 | 6 | 41 |
5 | 13 | 976.52 | 36 | 13.37 | 1029 | 495 | 4.12 / 683.21 | 6 | 45 |
6 | 13 | 433.08 | 36 | 13.90 | 619 | 310 | 4.43 / 683.52 | 6 | 38 |
7 | 13 | 44.72 | 36 | 14.34 | 320 | 165 | 4.60 / 683.69 | 6 | 31 |
8 | 8 | 0.04 | 450 | 14.25 | 289 | 1853 | 6.45 / 685.54 | 6 | 51 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 70 | 14.30 | 358 | 358 | 0.36 / 672.96 | 6 | 7 |
2 | 7 | 2009.28 | 105 | 10.97 | 1669 | 1922 | 2.28 / 674.89 | 6 | 20 |
3 | 13 | 1911.80 | 36 | 12.63 | 1639 | 745 | 3.03 / 675.63 | 6 | 31 |
4 | 13 | 1605.80 | 36 | 12.94 | 1448 | 675 | 3.70 / 676.31 | 6 | 38 |
5 | 13 | 1060.96 | 36 | 13.29 | 1083 | 518 | 4.22 / 676.82 | 6 | 45 |
6 | 13 | 416.28 | 36 | 13.93 | 608 | 305 | 4.52 / 677.13 | 6 | 38 |
7 | 13 | 40.76 | 36 | 14.36 | 314 | 162 | 4.69 / 677.29 | 6 | 30 |
8 | 8 | 0.04 | 450 | 14.26 | 280 | 1797 | 6.48 / 679.09 | 6 | 56 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 70 | 14.28 | 361 | 361 | 0.36 / 666.50 | 6 | 7 |
2 | 7 | 2002.36 | 106 | 11.03 | 1674 | 1957 | 2.32 / 668.46 | 6 | 20 |
3 | 13 | 1911.00 | 36 | 12.62 | 1642 | 746 | 3.06 / 669.21 | 6 | 31 |
4 | 13 | 1494.76 | 36 | 12.98 | 1387 | 648 | 3.71 / 669.86 | 6 | 40 |
5 | 13 | 963.44 | 36 | 13.35 | 1028 | 494 | 4.21 / 670.35 | 6 | 46 |
6 | 13 | 225.72 | 36 | 14.14 | 461 | 235 | 4.44 / 670.58 | 6 | 31 |
7 | 13 | 28.28 | 36 | 14.36 | 320 | 165 | 4.61 / 670.75 | 6 | 29 |
8 | 8 | 0.08 | 450 | 14.23 | 290 | 1857 | 6.46 / 672.61 | 6 | 56 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 70 | 14.30 | 358 | 358 | 0.36 / 660.03 | 6 | 8 |
2 | 7 | 2011.96 | 105 | 11.05 | 1679 | 1948 | 2.31 / 661.98 | 8 | 21 |
3 | 13 | 1918.44 | 36 | 12.60 | 1649 | 748 | 3.05 / 662.72 | 6 | 31 |
4 | 13 | 1407.84 | 36 | 13.03 | 1331 | 624 | 3.68 / 663.35 | 6 | 40 |
5 | 13 | 880.36 | 36 | 13.42 | 966 | 467 | 4.15 / 663.82 | 6 | 46 |
6 | 13 | 351.16 | 36 | 13.97 | 560 | 282 | 4.43 / 664.10 | 6 | 38 |
7 | 13 | 29.04 | 36 | 14.34 | 321 | 166 | 4.59 / 664.26 | 6 | 31 |
8 | 8 | 0.08 | 450 | 14.21 | 294 | 1880 | 6.47 / 666.14 | 6 | 57 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 70 | 14.25 | 364 | 363 | 0.36 / 653.60 | 6 | 8 |
2 | 7 | 2010.12 | 105 | 11.07 | 1682 | 1955 | 2.32 / 655.56 | 8 | 20 |
3 | 13 | 1920.52 | 36 | 12.59 | 1655 | 750 | 3.07 / 656.31 | 6 | 32 |
4 | 13 | 1412.52 | 36 | 13.01 | 1334 | 625 | 3.69 / 656.93 | 6 | 41 |
5 | 13 | 866.08 | 36 | 13.41 | 960 | 463 | 4.16 / 657.39 | 6 | 46 |
6 | 13 | 227.80 | 36 | 14.10 | 468 | 238 | 4.39 / 657.63 | 6 | 35 |
7 | 13 | 27.96 | 36 | 14.33 | 323 | 167 | 4.56 / 657.80 | 6 | 32 |
8 | 8 | 0.04 | 450 | 14.20 | 293 | 1872 | 6.43 / 659.67 | 6 | 58 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 70 | 14.29 | 364 | 364 | 0.36 / 647.17 | 6 | 8 |
2 | 7 | 2012.56 | 105 | 11.07 | 1679 | 1952 | 2.32 / 649.12 | 8 | 21 |
3 | 13 | 1922.08 | 36 | 12.58 | 1658 | 751 | 3.07 / 649.87 | 6 | 33 |
4 | 13 | 1403.04 | 36 | 13.03 | 1323 | 621 | 3.69 / 650.49 | 6 | 42 |
5 | 13 | 875.32 | 36 | 13.40 | 964 | 465 | 4.15 / 650.96 | 6 | 48 |
6 | 13 | 337.84 | 36 | 13.97 | 556 | 280 | 4.43 / 651.23 | 6 | 38 |
7 | 13 | 24.92 | 36 | 14.33 | 314 | 162 | 4.59 / 651.40 | 6 | 33 |
8 | 8 | 0.12 | 450 | 14.20 | 288 | 1840 | 6.43 / 653.24 | 6 | 62 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 70 | 14.29 | 357 | 357 | 0.36 / 640.71 | 6 | 8 |
2 | 7 | 2003.28 | 105 | 11.08 | 1675 | 1949 | 2.31 / 642.66 | 8 | 20 |
3 | 13 | 1916.12 | 36 | 12.58 | 1644 | 745 | 3.05 / 643.41 | 6 | 32 |
4 | 13 | 1393.24 | 36 | 13.04 | 1316 | 618 | 3.67 / 644.02 | 6 | 41 |
5 | 13 | 963.32 | 36 | 13.34 | 1028 | 494 | 4.16 / 644.52 | 6 | 47 |
6 | 13 | 217.32 | 36 | 14.13 | 462 | 235 | 4.40 / 644.75 | 6 | 32 |
7 | 13 | 25.80 | 36 | 14.35 | 316 | 163 | 4.56 / 644.92 | 6 | 30 |
8 | 8 | 0.04 | 450 | 14.21 | 295 | 1886 | 6.45 / 646.80 | 6 | 63 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 70 | 14.29 | 360 | 360 | 0.36 / 634.49 | 6 | 8 |
2 | 7 | 2012.04 | 106 | 11.10 | 1680 | 1977 | 2.34 / 636.47 | 8 | 20 |
3 | 13 | 1915.72 | 36 | 12.58 | 1644 | 745 | 3.08 / 637.21 | 6 | 31 |
4 | 13 | 1389.48 | 36 | 13.03 | 1318 | 618 | 3.70 / 637.83 | 6 | 40 |
5 | 13 | 871.80 | 36 | 13.41 | 959 | 463 | 4.16 / 638.29 | 6 | 45 |
6 | 13 | 238.52 | 36 | 14.12 | 473 | 240 | 4.40 / 638.53 | 6 | 33 |
7 | 8 | 0.00 | 450 | 14.23 | 285 | 1825 | 6.23 / 640.36 | 6 | 59 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 70 | 14.29 | 366 | 366 | 0.37 / 627.94 | 6 | 8 |
2 | 7 | 2000.96 | 106 | 11.10 | 1668 | 1963 | 2.33 / 629.90 | 8 | 20 |
3 | 13 | 1905.60 | 36 | 12.59 | 1638 | 742 | 3.07 / 630.64 | 6 | 32 |
4 | 13 | 1480.84 | 36 | 12.97 | 1376 | 642 | 3.71 / 631.29 | 6 | 41 |
5 | 13 | 940.16 | 36 | 13.35 | 1011 | 486 | 4.20 / 631.77 | 6 | 47 |
6 | 13 | 198.96 | 36 | 14.15 | 448 | 228 | 4.43 / 632.00 | 6 | 31 |
7 | 13 | 20.20 | 36 | 14.36 | 311 | 161 | 4.59 / 632.16 | 6 | 31 |
8 | 13 | 7.20 | 36 | 14.26 | 301 | 155 | 4.74 / 632.32 | 6 | 30 |
9 | 8 | -0.12 | 450 | 14.19 | 284 | 1813 | 6.56 / 634.13 | 6 | 62 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 70 | 14.31 | 357 | 358 | 0.36 / 621.47 | 6 | 7 |
2 | 7 | 2001.92 | 105 | 11.13 | 1671 | 1953 | 2.31 / 623.42 | 7 | 21 |
3 | 13 | 1911.64 | 36 | 12.58 | 1643 | 744 | 3.05 / 624.17 | 6 | 32 |
4 | 13 | 1377.08 | 36 | 13.05 | 1306 | 614 | 3.67 / 624.78 | 6 | 41 |
5 | 13 | 952.44 | 36 | 13.35 | 1019 | 490 | 4.16 / 625.27 | 6 | 47 |
6 | 13 | 308.32 | 36 | 14.03 | 529 | 267 | 4.42 / 625.54 | 6 | 36 |
7 | 13 | 5.08 | 36 | 14.38 | 297 | 154 | 4.58 / 625.69 | 6 | 32 |
8 | 8 | 0.08 | 450 | 14.18 | 295 | 1882 | 6.46 / 627.57 | 6 | 59 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 70 | 14.30 | 361 | 361 | 0.36 / 614.97 | 6 | 7 |
2 | 7 | 2004.28 | 105 | 11.14 | 1678 | 1963 | 2.32 / 616.93 | 7 | 21 |
3 | 13 | 1913.68 | 36 | 12.57 | 1646 | 745 | 3.07 / 617.68 | 6 | 32 |
4 | 13 | 1492.48 | 36 | 12.96 | 1384 | 646 | 3.71 / 618.32 | 6 | 40 |
5 | 13 | 858.28 | 36 | 13.44 | 949 | 459 | 4.17 / 618.78 | 6 | 46 |
6 | 13 | 324.72 | 36 | 14.01 | 542 | 273 | 4.45 / 619.06 | 6 | 36 |
7 | 13 | 47.32 | 36 | 14.34 | 325 | 168 | 4.61 / 619.22 | 6 | 30 |
8 | 8 | 0.04 | 450 | 14.21 | 295 | 1886 | 6.50 / 621.11 | 6 | 58 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 70 | 14.33 | 359 | 360 | 0.36 / 608.56 | 6 | 7 |
2 | 7 | 2013.36 | 105 | 11.17 | 1681 | 1972 | 2.33 / 610.53 | 7 | 20 |
3 | 13 | 1915.68 | 36 | 12.57 | 1645 | 744 | 3.08 / 611.28 | 6 | 32 |
4 | 13 | 1380.48 | 36 | 13.05 | 1306 | 614 | 3.69 / 611.89 | 6 | 42 |
5 | 13 | 858.28 | 36 | 13.43 | 957 | 463 | 4.15 / 612.35 | 6 | 45 |
6 | 13 | 326.28 | 36 | 14.02 | 541 | 273 | 4.43 / 612.63 | 6 | 36 |
7 | 13 | 48.12 | 36 | 14.35 | 324 | 167 | 4.59 / 612.79 | 6 | 30 |
8 | 8 | 0.12 | 450 | 14.25 | 283 | 1815 | 6.41 / 614.61 | 6 | 57 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 70 | 14.32 | 369 | 370 | 0.37 / 602.09 | 6 | 7 |
2 | 7 | 2002.08 | 105 | 11.17 | 1678 | 1968 | 2.34 / 604.06 | 7 | 21 |
3 | 13 | 1910.08 | 36 | 12.56 | 1646 | 744 | 3.08 / 604.80 | 6 | 32 |
4 | 13 | 1489.84 | 36 | 12.97 | 1388 | 648 | 3.73 / 605.45 | 6 | 41 |
5 | 13 | 842.40 | 36 | 13.45 | 944 | 457 | 4.19 / 605.91 | 6 | 47 |
6 | 13 | 224.72 | 36 | 14.14 | 470 | 239 | 4.43 / 606.15 | 6 | 32 |
7 | 13 | 58.84 | 36 | 14.35 | 338 | 175 | 4.60 / 606.32 | 6 | 28 |
8 | 8 | 0.04 | 450 | 14.25 | 293 | 1879 | 6.48 / 608.20 | 6 | 59 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 70 | 14.36 | 354 | 356 | 0.36 / 595.49 | 6 | 7 |
2 | 7 | 2012.32 | 105 | 11.18 | 1683 | 1976 | 2.33 / 597.47 | 7 | 21 |
3 | 13 | 1920.72 | 36 | 12.58 | 1651 | 748 | 3.08 / 598.22 | 6 | 31 |
4 | 13 | 1508.64 | 36 | 12.98 | 1390 | 650 | 3.73 / 598.87 | 6 | 40 |
5 | 13 | 960.28 | 36 | 13.37 | 1023 | 492 | 4.22 / 599.36 | 6 | 46 |
6 | 13 | 413.48 | 36 | 13.93 | 609 | 305 | 4.53 / 599.67 | 6 | 39 |
7 | 13 | 44.28 | 36 | 14.35 | 335 | 173 | 4.70 / 599.84 | 6 | 29 |
8 | 8 | 0.04 | 450 | 14.24 | 294 | 1884 | 6.58 / 601.72 | 6 | 50 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 70 | 14.37 | 352 | 354 | 0.35 / 589.01 | 6 | 7 |
2 | 7 | 2006.20 | 105 | 11.24 | 1674 | 1976 | 2.33 / 590.98 | 6 | 21 |
3 | 13 | 1905.52 | 36 | 12.59 | 1636 | 742 | 3.07 / 591.72 | 6 | 31 |
4 | 13 | 1593.00 | 36 | 12.91 | 1448 | 673 | 3.74 / 592.40 | 6 | 39 |
5 | 13 | 915.20 | 36 | 13.39 | 991 | 478 | 4.22 / 592.87 | 6 | 46 |
6 | 13 | 379.28 | 36 | 13.97 | 579 | 291 | 4.51 / 593.17 | 6 | 38 |
7 | 13 | 39.56 | 36 | 14.38 | 317 | 164 | 4.68 / 593.33 | 6 | 29 |
8 | 8 | 0.24 | 450 | 14.25 | 282 | 1808 | 6.49 / 595.14 | 6 | 57 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 70 | 14.38 | 337 | 339 | 0.34 / 582.59 | 6 | 7 |
2 | 7 | 2002.32 | 105 | 11.26 | 1675 | 1980 | 2.32 / 584.57 | 7 | 21 |
3 | 13 | 1911.56 | 36 | 12.58 | 1640 | 743 | 3.06 / 585.32 | 6 | 32 |
4 | 13 | 1401.24 | 36 | 13.02 | 1323 | 620 | 3.68 / 585.94 | 6 | 40 |
5 | 13 | 871.76 | 36 | 13.44 | 957 | 463 | 4.15 / 586.40 | 6 | 46 |
6 | 13 | 237.24 | 36 | 14.15 | 464 | 236 | 4.38 / 586.64 | 6 | 33 |
7 | 13 | 73.40 | 36 | 14.36 | 340 | 176 | 4.56 / 586.81 | 6 | 29 |
8 | 8 | 0.24 | 450 | 14.26 | 287 | 1842 | 6.40 / 588.65 | 6 | 51 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 70 | 14.36 | 355 | 357 | 0.36 / 576.21 | 6 | 7 |
2 | 7 | 2013.12 | 105 | 11.28 | 1686 | 1997 | 2.35 / 578.20 | 7 | 22 |
3 | 13 | 1923.20 | 36 | 12.57 | 1654 | 748 | 3.10 / 578.95 | 6 | 32 |
4 | 13 | 1285.72 | 36 | 13.11 | 1244 | 587 | 3.69 / 579.54 | 6 | 43 |
5 | 13 | 867.04 | 36 | 13.45 | 954 | 462 | 4.15 / 580.00 | 6 | 47 |
6 | 13 | 425.84 | 36 | 13.91 | 615 | 308 | 4.46 / 580.31 | 6 | 40 |
7 | 13 | 53.80 | 36 | 14.36 | 323 | 167 | 4.63 / 580.48 | 6 | 30 |
8 | 8 | 0.04 | 450 | 14.27 | 277 | 1779 | 6.40 / 582.25 | 6 | 53 |
Average= | 6.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 70 | 14.39 | 349 | 352 | 0.35 / 569.69 | 6 | 7 |
2 | 7 | 2011.60 | 105 | 11.30 | 1688 | 2003 | 2.35 / 571.69 | 7 | 22 |
3 | 13 | 1918.28 | 36 | 12.59 | 1647 | 746 | 3.10 / 572.44 | 6 | 32 |
4 | 13 | 1283.32 | 36 | 13.11 | 1247 | 589 | 3.69 / 573.03 | 6 | 43 |
5 | 13 | 965.76 | 36 | 13.35 | 1034 | 497 | 4.19 / 573.53 | 6 | 48 |
6 | 13 | 319.08 | 36 | 14.03 | 545 | 275 | 4.46 / 573.80 | 6 | 36 |
7 | 13 | 47.24 | 36 | 14.34 | 341 | 176 | 4.64 / 573.98 | 6 | 29 |
8 | 8 | 0.16 | 450 | 14.24 | 292 | 1871 | 6.51 / 575.85 | 6 | 56 |
Average= | 6.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 70 | 14.37 | 351 | 353 | 0.35 / 563.20 | 6 | 7 |
2 | 7 | 2008.52 | 106 | 11.31 | 1677 | 2010 | 2.36 / 565.21 | 7 | 22 |
3 | 13 | 1910.28 | 36 | 12.57 | 1648 | 746 | 3.11 / 565.96 | 6 | 33 |
4 | 13 | 1392.84 | 36 | 13.04 | 1317 | 618 | 3.73 / 566.58 | 6 | 42 |
5 | 13 | 949.52 | 36 | 13.37 | 1020 | 491 | 4.22 / 567.07 | 6 | 47 |
6 | 13 | 201.76 | 36 | 14.18 | 447 | 228 | 4.45 / 567.30 | 6 | 33 |
7 | 13 | 50.56 | 36 | 14.35 | 333 | 172 | 4.62 / 567.47 | 6 | 30 |
8 | 8 | 0.08 | 450 | 14.24 | 292 | 1871 | 6.49 / 569.34 | 6 | 58 |
Average= | 6.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 70 | 14.38 | 344 | 346 | 0.35 / 556.80 | 6 | 7 |
2 | 7 | 2001.04 | 105 | 11.34 | 1675 | 1994 | 2.34 / 558.80 | 7 | 22 |
3 | 13 | 1908.08 | 36 | 12.60 | 1636 | 742 | 3.08 / 559.54 | 6 | 32 |
4 | 13 | 1372.04 | 36 | 13.05 | 1302 | 612 | 3.69 / 560.15 | 6 | 43 |
5 | 13 | 851.28 | 36 | 13.46 | 945 | 458 | 4.15 / 560.61 | 6 | 47 |
6 | 13 | 319.52 | 36 | 14.05 | 532 | 269 | 4.42 / 560.88 | 6 | 37 |
7 | 13 | 49.68 | 36 | 14.36 | 328 | 170 | 4.59 / 561.05 | 6 | 31 |
8 | 8 | 0.12 | 450 | 14.25 | 281 | 1802 | 6.39 / 562.85 | 6 | 59 |
Average= | 6.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 70 | 14.39 | 360 | 363 | 0.36 / 550.47 | 6 | 7 |
2 | 7 | 2001.84 | 105 | 11.33 | 1671 | 1988 | 2.35 / 552.46 | 7 | 22 |
3 | 13 | 1908.80 | 36 | 12.61 | 1635 | 742 | 3.09 / 553.20 | 6 | 31 |
4 | 13 | 1369.84 | 36 | 13.07 | 1297 | 610 | 3.70 / 553.81 | 6 | 42 |
5 | 13 | 751.44 | 36 | 13.55 | 871 | 425 | 4.13 / 554.24 | 6 | 47 |
6 | 13 | 234.28 | 36 | 14.14 | 472 | 240 | 4.37 / 554.48 | 6 | 34 |
7 | 13 | 62.24 | 36 | 14.34 | 337 | 174 | 4.54 / 554.65 | 6 | 31 |
8 | 8 | 0.08 | 450 | 14.24 | 282 | 1807 | 6.35 / 556.46 | 6 | 56 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 70 | 14.37 | 351 | 353 | 0.35 / 543.82 | 6 | 7 |
2 | 7 | 2001.64 | 105 | 11.37 | 1682 | 2008 | 2.36 / 545.83 | 7 | 22 |
3 | 13 | 1908.40 | 36 | 12.61 | 1644 | 746 | 3.11 / 546.58 | 6 | 32 |
4 | 13 | 1478.68 | 36 | 13.00 | 1370 | 641 | 3.75 / 547.22 | 6 | 41 |
5 | 13 | 828.20 | 36 | 13.48 | 933 | 453 | 4.20 / 547.67 | 6 | 46 |
6 | 13 | 294.60 | 36 | 14.07 | 524 | 265 | 4.47 / 547.94 | 6 | 36 |
7 | 13 | 46.16 | 36 | 14.35 | 334 | 173 | 4.64 / 548.11 | 6 | 31 |
8 | 13 | 23.28 | 36 | 14.30 | 317 | 163 | 4.80 / 548.27 | 6 | 32 |
9 | 8 | -0.04 | 450 | 14.22 | 287 | 1837 | 6.64 / 550.11 | 6 | 64 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 70 | 14.34 | 357 | 358 | 0.36 / 537.40 | 6 | 7 |
2 | 7 | 2002.84 | 105 | 11.37 | 1671 | 1995 | 2.35 / 539.40 | 7 | 22 |
3 | 13 | 1914.16 | 36 | 12.59 | 1645 | 746 | 3.10 / 540.14 | 6 | 32 |
4 | 13 | 1288.16 | 36 | 13.12 | 1246 | 589 | 3.69 / 540.73 | 6 | 42 |
5 | 13 | 867.56 | 36 | 13.45 | 957 | 463 | 4.15 / 541.19 | 6 | 47 |
6 | 13 | 225.32 | 36 | 14.16 | 472 | 241 | 4.39 / 541.43 | 6 | 33 |
7 | 13 | 56.32 | 36 | 14.35 | 342 | 177 | 4.57 / 541.61 | 6 | 31 |
8 | 8 | -0.04 | 450 | 14.24 | 290 | 1858 | 6.43 / 543.47 | 6 | 52 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 70 | 14.42 | 336 | 339 | 0.34 / 531.04 | 6 | 7 |
2 | 7 | 2006.00 | 105 | 11.39 | 1678 | 2007 | 2.35 / 533.04 | 7 | 23 |
3 | 13 | 1907.72 | 36 | 12.58 | 1644 | 745 | 3.09 / 533.79 | 6 | 32 |
4 | 13 | 1281.16 | 36 | 13.13 | 1240 | 586 | 3.68 / 534.38 | 6 | 44 |
5 | 13 | 864.76 | 36 | 13.48 | 950 | 461 | 4.14 / 534.84 | 6 | 47 |
6 | 13 | 220.92 | 36 | 14.17 | 462 | 236 | 4.37 / 535.07 | 6 | 33 |
7 | 13 | 33.20 | 36 | 14.39 | 316 | 164 | 4.54 / 535.24 | 6 | 30 |
8 | 8 | -0.12 | 450 | 14.24 | 282 | 1807 | 6.34 / 537.04 | 6 | 54 |
Average= | 6.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 70 | 14.43 | 342 | 345 | 0.35 / 524.71 | 6 | 7 |
2 | 7 | 2001.64 | 105 | 11.33 | 1675 | 1993 | 2.34 / 526.70 | 7 | 22 |
3 | 13 | 1909.68 | 36 | 12.60 | 1643 | 745 | 3.08 / 527.45 | 6 | 33 |
4 | 13 | 1290.20 | 36 | 13.14 | 1244 | 588 | 3.67 / 528.04 | 6 | 43 |
5 | 13 | 863.08 | 36 | 13.49 | 952 | 462 | 4.13 / 528.50 | 6 | 47 |
6 | 13 | 221.72 | 36 | 14.19 | 457 | 233 | 4.37 / 528.73 | 6 | 33 |
7 | 13 | 53.36 | 36 | 14.37 | 330 | 171 | 4.54 / 528.90 | 6 | 30 |
8 | 8 | 0.08 | 450 | 14.25 | 280 | 1795 | 6.33 / 530.70 | 6 | 53 |
Average= | 6.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 70 | 14.42 | 345 | 348 | 0.35 / 518.26 | 6 | 7 |
2 | 7 | 2009.52 | 105 | 11.30 | 1681 | 1995 | 2.34 / 520.26 | 7 | 21 |
3 | 13 | 1911.60 | 36 | 12.63 | 1639 | 745 | 3.09 / 521.00 | 6 | 32 |
4 | 13 | 1391.08 | 36 | 13.06 | 1317 | 619 | 3.71 / 521.62 | 6 | 42 |
5 | 13 | 863.84 | 36 | 13.50 | 950 | 462 | 4.17 / 522.08 | 6 | 47 |
6 | 13 | 329.72 | 36 | 14.08 | 541 | 274 | 4.44 / 522.36 | 6 | 35 |
7 | 13 | 48.64 | 36 | 14.38 | 329 | 170 | 4.61 / 522.53 | 6 | 30 |
8 | 8 | 0.08 | 450 | 14.26 | 286 | 1835 | 6.45 / 524.36 | 6 | 52 |
Average= | 6.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 69 | 14.41 | 345 | 343 | 0.34 / 511.84 | 6 | 6 |
2 | 7 | 2003.84 | 105 | 11.34 | 1670 | 1988 | 2.33 / 513.83 | 6 | 21 |
3 | 13 | 1908.56 | 36 | 12.64 | 1635 | 744 | 3.08 / 514.57 | 6 | 31 |
4 | 13 | 1470.80 | 36 | 13.04 | 1368 | 642 | 3.72 / 515.22 | 6 | 40 |
5 | 13 | 827.28 | 36 | 13.55 | 917 | 447 | 4.16 / 515.66 | 6 | 45 |
6 | 13 | 290.20 | 36 | 14.14 | 509 | 259 | 4.42 / 515.92 | 6 | 33 |
7 | 13 | 42.92 | 36 | 14.40 | 318 | 165 | 4.59 / 516.09 | 6 | 29 |
8 | 8 | 0.00 | 450 | 14.26 | 285 | 1829 | 6.42 / 517.92 | 6 | 54 |
Average= | 6.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 69 | 14.43 | 340 | 339 | 0.34 / 505.20 | 6 | 7 |
2 | 7 | 2004.32 | 105 | 11.35 | 1674 | 1995 | 2.33 / 507.20 | 7 | 21 |
3 | 13 | 1913.60 | 36 | 12.63 | 1645 | 748 | 3.08 / 507.94 | 6 | 32 |
4 | 13 | 1482.28 | 36 | 13.05 | 1374 | 646 | 3.73 / 508.59 | 6 | 40 |
5 | 13 | 942.40 | 36 | 13.46 | 1005 | 487 | 4.21 / 509.08 | 6 | 46 |
6 | 13 | 287.92 | 36 | 14.13 | 519 | 264 | 4.48 / 509.34 | 6 | 33 |
7 | 13 | 48.64 | 36 | 14.41 | 321 | 167 | 4.64 / 509.51 | 6 | 28 |
8 | 13 | 24.44 | 36 | 14.35 | 313 | 162 | 4.81 / 509.67 | 6 | 29 |
9 | 8 | 0.00 | 450 | 14.26 | 285 | 1829 | 6.64 / 511.50 | 6 | 53 |
Average= | 6.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 69 | 14.41 | 348 | 346 | 0.35 / 498.78 | 6 | 7 |
2 | 3 | 1009.64 | 1 | 10.96 | 1022 | 11 | 0.36 / 498.79 | 6 | 6 |
3 | 7 | 2006.88 | 105 | 11.40 | 1674 | 2004 | 2.36 / 500.79 | 6 | 22 |
4 | 13 | 1907.48 | 36 | 12.67 | 1638 | 747 | 3.11 / 501.54 | 6 | 32 |
5 | 13 | 1388.76 | 36 | 13.13 | 1311 | 620 | 3.73 / 502.16 | 6 | 41 |
6 | 13 | 855.48 | 36 | 13.55 | 941 | 459 | 4.19 / 502.62 | 6 | 47 |
7 | 13 | 217.48 | 36 | 14.22 | 464 | 238 | 4.42 / 502.86 | 6 | 30 |
8 | 13 | 55.40 | 36 | 14.39 | 338 | 175 | 4.60 / 503.03 | 6 | 28 |
9 | 8 | 0.04 | 450 | 14.27 | 285 | 1830 | 6.43 / 504.86 | 6 | 53 |
Average= | 6.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 69 | 14.44 | 339 | 338 | 0.34 / 492.42 | 6 | 7 |
2 | 7 | 2010.24 | 105 | 11.42 | 1682 | 2017 | 2.35 / 494.43 | 6 | 22 |
3 | 13 | 1910.28 | 36 | 12.67 | 1640 | 748 | 3.10 / 495.18 | 6 | 32 |
4 | 13 | 1396.00 | 36 | 13.12 | 1319 | 623 | 3.73 / 495.81 | 6 | 42 |
5 | 13 | 762.76 | 36 | 13.63 | 875 | 429 | 4.16 / 496.23 | 6 | 46 |
6 | 13 | 234.72 | 36 | 14.20 | 473 | 242 | 4.40 / 496.48 | 6 | 34 |
7 | 13 | 35.40 | 36 | 14.42 | 317 | 165 | 4.56 / 496.64 | 6 | 29 |
8 | 8 | 0.04 | 450 | 14.28 | 279 | 1793 | 6.35 / 498.43 | 6 | 59 |
Average= | 6.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 69 | 14.43 | 346 | 345 | 0.34 / 486.08 | 6 | 7 |
2 | 7 | 2000.96 | 105 | 11.46 | 1672 | 2012 | 2.36 / 488.09 | 7 | 22 |
3 | 13 | 1905.92 | 36 | 12.68 | 1635 | 746 | 3.10 / 488.83 | 6 | 32 |
4 | 13 | 1378.92 | 36 | 13.13 | 1311 | 620 | 3.72 / 489.45 | 6 | 43 |
5 | 13 | 844.52 | 36 | 13.56 | 935 | 456 | 4.18 / 489.91 | 6 | 47 |
6 | 13 | 201.72 | 36 | 14.25 | 440 | 226 | 4.40 / 490.14 | 6 | 31 |
7 | 13 | 26.68 | 36 | 14.43 | 308 | 160 | 4.56 / 490.30 | 6 | 30 |
8 | 8 | -0.04 | 450 | 14.25 | 278 | 1783 | 6.35 / 492.08 | 6 | 58 |
Average= | 6.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 69 | 14.40 | 343 | 341 | 0.34 / 479.69 | 6 | 6 |
2 | 7 | 2002.44 | 105 | 11.49 | 1674 | 2020 | 2.36 / 481.71 | 6 | 23 |
3 | 13 | 1910.52 | 36 | 12.69 | 1639 | 749 | 3.11 / 482.46 | 6 | 32 |
4 | 13 | 1379.52 | 36 | 13.14 | 1302 | 616 | 3.73 / 483.07 | 6 | 42 |
5 | 13 | 855.04 | 36 | 13.55 | 945 | 461 | 4.19 / 483.54 | 6 | 47 |
6 | 13 | 117.72 | 36 | 14.33 | 373 | 192 | 4.38 / 483.73 | 6 | 30 |
7 | 13 | 33.56 | 36 | 14.40 | 321 | 166 | 4.54 / 483.89 | 6 | 31 |
8 | 8 | 0.60 | 450 | 14.23 | 287 | 1838 | 6.38 / 485.73 | 6 | 60 |
Average= | 6.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 69 | 14.43 | 337 | 336 | 0.34 / 473.13 | 6 | 6 |
2 | 7 | 2010.80 | 105 | 11.43 | 1683 | 2020 | 2.36 / 475.15 | 6 | 22 |
3 | 13 | 1911.20 | 36 | 12.70 | 1640 | 750 | 3.11 / 475.90 | 6 | 33 |
4 | 13 | 1369.88 | 36 | 13.17 | 1297 | 615 | 3.72 / 476.52 | 6 | 43 |
5 | 13 | 844.96 | 36 | 13.57 | 935 | 457 | 4.18 / 476.97 | 6 | 48 |
6 | 13 | 204.84 | 36 | 14.23 | 449 | 230 | 4.41 / 477.20 | 6 | 34 |
7 | 13 | 26.48 | 36 | 14.42 | 316 | 164 | 4.57 / 477.37 | 6 | 31 |
8 | 13 | 14.76 | 36 | 14.30 | 304 | 156 | 4.73 / 477.52 | 6 | 32 |
9 | 8 | 0.00 | 450 | 14.18 | 286 | 1825 | 6.55 / 479.35 | 6 | 67 |
Average= | 6.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 69 | 14.44 | 339 | 338 | 0.34 / 466.85 | 6 | 7 |
2 | 7 | 2008.24 | 105 | 11.47 | 1677 | 2020 | 2.36 / 468.87 | 7 | 23 |
3 | 13 | 1813.72 | 36 | 12.82 | 1584 | 731 | 3.09 / 469.60 | 6 | 34 |
4 | 13 | 1292.24 | 36 | 13.23 | 1246 | 593 | 3.68 / 470.19 | 6 | 44 |
5 | 13 | 769.36 | 36 | 13.64 | 885 | 435 | 4.12 / 470.63 | 6 | 47 |
6 | 13 | 228.84 | 36 | 14.22 | 461 | 236 | 4.35 / 470.86 | 6 | 34 |
7 | 13 | 31.44 | 36 | 14.44 | 307 | 160 | 4.51 / 471.02 | 6 | 29 |
8 | 8 | 0.32 | 450 | 14.25 | 277 | 1776 | 6.29 / 472.80 | 6 | 57 |
Average= | 6.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 69 | 14.42 | 340 | 338 | 0.34 / 460.49 | 6 | 6 |
2 | 7 | 2001.00 | 105 | 11.48 | 1674 | 2018 | 2.36 / 462.51 | 6 | 24 |
3 | 13 | 1904.56 | 36 | 12.72 | 1644 | 753 | 3.11 / 463.26 | 6 | 33 |
4 | 13 | 1368.72 | 36 | 13.19 | 1296 | 615 | 3.72 / 463.87 | 6 | 43 |
5 | 13 | 833.84 | 36 | 13.61 | 926 | 454 | 4.18 / 464.33 | 6 | 48 |
6 | 13 | 284.80 | 36 | 14.16 | 506 | 258 | 4.44 / 464.59 | 6 | 36 |
7 | 13 | 43.24 | 36 | 14.43 | 313 | 163 | 4.60 / 464.75 | 6 | 31 |
8 | 8 | 0.00 | 450 | 14.28 | 274 | 1761 | 6.36 / 466.51 | 6 | 52 |
Average= | 6.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 69 | 14.42 | 354 | 352 | 0.35 / 454.06 | 6 | 7 |
2 | 7 | 2012.12 | 105 | 11.46 | 1683 | 2025 | 2.38 / 456.08 | 7 | 22 |
3 | 13 | 1914.80 | 36 | 12.72 | 1646 | 754 | 3.13 / 456.84 | 6 | 33 |
4 | 13 | 1383.88 | 36 | 13.18 | 1307 | 620 | 3.75 / 457.46 | 6 | 42 |
5 | 13 | 943.44 | 36 | 13.51 | 1014 | 493 | 4.24 / 457.95 | 6 | 47 |
6 | 13 | 185.76 | 36 | 14.29 | 424 | 218 | 4.46 / 458.17 | 6 | 33 |
7 | 13 | 45.60 | 36 | 14.43 | 317 | 165 | 4.63 / 458.33 | 6 | 30 |
8 | 8 | 0.20 | 450 | 14.27 | 283 | 1817 | 6.44 / 460.15 | 6 | 55 |
Average= | 6.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 69 | 14.40 | 353 | 351 | 0.35 / 447.52 | 6 | 7 |
2 | 7 | 2013.40 | 106 | 11.44 | 1684 | 2042 | 2.39 / 449.56 | 7 | 24 |
3 | 13 | 1918.00 | 36 | 12.72 | 1653 | 757 | 3.15 / 450.32 | 6 | 34 |
4 | 13 | 1383.84 | 36 | 13.20 | 1304 | 620 | 3.77 / 450.94 | 6 | 44 |
5 | 13 | 939.20 | 36 | 13.53 | 1010 | 492 | 4.26 / 451.43 | 6 | 48 |
6 | 13 | 263.80 | 36 | 14.18 | 491 | 251 | 4.51 / 451.68 | 6 | 35 |
7 | 13 | 35.56 | 36 | 14.41 | 326 | 169 | 4.68 / 451.85 | 6 | 32 |
8 | 8 | 0.04 | 450 | 14.22 | 290 | 1856 | 6.54 / 453.70 | 6 | 59 |
Average= | 6.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 69 | 14.40 | 359 | 357 | 0.36 / 441.09 | 6 | 7 |
2 | 7 | 2005.00 | 105 | 11.48 | 1675 | 2019 | 2.38 / 443.11 | 7 | 23 |
3 | 13 | 1809.88 | 36 | 12.87 | 1578 | 731 | 3.11 / 443.84 | 6 | 36 |
4 | 13 | 1491.28 | 36 | 13.17 | 1375 | 652 | 3.76 / 444.49 | 6 | 43 |
5 | 13 | 832.20 | 36 | 13.62 | 926 | 454 | 4.21 / 444.94 | 6 | 48 |
6 | 13 | 188.88 | 36 | 14.28 | 430 | 221 | 4.43 / 445.17 | 6 | 33 |
7 | 13 | 42.96 | 36 | 14.42 | 319 | 166 | 4.60 / 445.33 | 6 | 31 |
8 | 8 | 0.24 | 450 | 14.22 | 287 | 1837 | 6.44 / 447.17 | 6 | 51 |
Average= | 6.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 69 | 14.42 | 351 | 349 | 0.35 / 434.64 | 6 | 8 |
2 | 7 | 2002.56 | 105 | 11.50 | 1672 | 2019 | 2.37 / 436.66 | 8 | 24 |
3 | 13 | 1905.72 | 36 | 12.77 | 1636 | 752 | 3.12 / 437.41 | 6 | 34 |
4 | 13 | 1377.44 | 36 | 13.23 | 1305 | 622 | 3.74 / 438.03 | 6 | 43 |
5 | 13 | 837.16 | 36 | 13.62 | 936 | 459 | 4.20 / 438.49 | 6 | 49 |
6 | 13 | 187.36 | 36 | 14.28 | 433 | 223 | 4.42 / 438.71 | 6 | 34 |
7 | 13 | 18.96 | 36 | 14.43 | 315 | 164 | 4.59 / 438.88 | 6 | 31 |
8 | 8 | -0.08 | 450 | 14.22 | 290 | 1856 | 6.44 / 440.73 | 6 | 53 |
Average= | 6.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 69 | 14.42 | 349 | 347 | 0.35 / 428.47 | 6 | 8 |
2 | 7 | 2006.88 | 105 | 11.49 | 1678 | 2024 | 2.37 / 430.50 | 8 | 24 |
3 | 13 | 1906.28 | 36 | 12.79 | 1637 | 754 | 3.13 / 431.25 | 6 | 34 |
4 | 13 | 1279.08 | 36 | 13.32 | 1238 | 594 | 3.72 / 431.84 | 6 | 45 |
5 | 13 | 848.64 | 36 | 13.64 | 939 | 461 | 4.18 / 432.31 | 6 | 49 |
6 | 13 | 104.28 | 36 | 14.37 | 377 | 195 | 4.38 / 432.50 | 6 | 31 |
7 | 8 | 0.04 | 450 | 14.25 | 279 | 1789 | 6.16 / 434.29 | 6 | 49 |
Average= | 6.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 69 | 14.38 | 367 | 364 | 0.36 / 422.33 | 6 | 8 |
2 | 7 | 2009.24 | 106 | 11.53 | 1677 | 2050 | 2.41 / 424.38 | 8 | 24 |
3 | 13 | 1910.12 | 36 | 12.81 | 1638 | 755 | 3.17 / 425.13 | 6 | 34 |
4 | 13 | 1268.28 | 36 | 13.33 | 1228 | 589 | 3.76 / 425.72 | 6 | 44 |
5 | 13 | 750.36 | 36 | 13.73 | 863 | 427 | 4.18 / 426.15 | 6 | 49 |
6 | 13 | 110.24 | 36 | 14.37 | 371 | 192 | 4.38 / 426.34 | 6 | 30 |
7 | 8 | 0.04 | 450 | 14.25 | 278 | 1783 | 6.16 / 428.13 | 6 | 57 |
Average= | 6.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 69 | 14.40 | 353 | 351 | 0.35 / 416.08 | 6 | 8 |
2 | 7 | 2009.48 | 106 | 11.53 | 1677 | 2050 | 2.40 / 418.13 | 8 | 24 |
3 | 13 | 1909.48 | 36 | 12.81 | 1639 | 756 | 3.16 / 418.89 | 6 | 34 |
4 | 13 | 1276.00 | 36 | 13.34 | 1238 | 595 | 3.75 / 419.48 | 6 | 45 |
5 | 13 | 753.00 | 36 | 13.73 | 871 | 431 | 4.18 / 419.91 | 6 | 47 |
6 | 13 | 114.64 | 36 | 14.37 | 376 | 195 | 4.38 / 420.11 | 6 | 30 |
7 | 8 | 0.12 | 450 | 14.24 | 290 | 1858 | 6.23 / 421.97 | 6 | 53 |
Average= | 6.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 69 | 14.41 | 356 | 354 | 0.35 / 409.91 | 6 | 8 |
2 | 7 | 2011.00 | 105 | 11.56 | 1675 | 2033 | 2.39 / 411.94 | 8 | 24 |
3 | 13 | 1916.68 | 36 | 12.84 | 1642 | 759 | 3.15 / 412.70 | 6 | 35 |
4 | 13 | 1267.44 | 36 | 13.35 | 1230 | 591 | 3.74 / 413.29 | 6 | 45 |
5 | 13 | 838.76 | 36 | 13.67 | 934 | 460 | 4.20 / 413.75 | 6 | 48 |
6 | 13 | 101.96 | 36 | 14.39 | 366 | 190 | 4.39 / 413.94 | 6 | 31 |
7 | 8 | 0.12 | 450 | 14.25 | 279 | 1789 | 6.18 / 415.73 | 6 | 57 |
Average= | 6.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 69 | 14.40 | 363 | 361 | 0.36 / 403.78 | 6 | 8 |
2 | 7 | 2003.24 | 105 | 11.62 | 1672 | 2040 | 2.40 / 405.82 | 8 | 25 |
3 | 13 | 1799.80 | 36 | 12.98 | 1574 | 735 | 3.14 / 406.56 | 6 | 37 |
4 | 13 | 1272.56 | 36 | 13.39 | 1225 | 590 | 3.73 / 407.15 | 6 | 45 |
5 | 13 | 745.44 | 36 | 13.76 | 859 | 426 | 4.15 / 407.57 | 6 | 48 |
6 | 13 | 203.44 | 36 | 14.29 | 440 | 226 | 4.38 / 407.80 | 6 | 34 |
7 | 8 | 0.08 | 450 | 14.25 | 274 | 1757 | 6.14 / 409.56 | 6 | 58 |
Average= | 6.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 69 | 14.41 | 357 | 355 | 0.35 / 397.60 | 6 | 8 |
2 | 7 | 2003.40 | 105 | 11.69 | 1673 | 2054 | 2.41 / 399.65 | 8 | 25 |
3 | 13 | 1904.16 | 36 | 12.89 | 1632 | 757 | 3.17 / 400.41 | 6 | 34 |
4 | 13 | 1171.28 | 36 | 13.45 | 1170 | 567 | 3.73 / 400.97 | 6 | 46 |
5 | 13 | 760.64 | 36 | 13.76 | 876 | 434 | 4.17 / 401.41 | 6 | 48 |
6 | 13 | 213.12 | 36 | 14.28 | 448 | 230 | 4.40 / 401.64 | 6 | 35 |
7 | 8 | 0.24 | 450 | 14.24 | 278 | 1781 | 6.18 / 403.42 | 6 | 59 |
Average= | 6.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 69 | 14.42 | 359 | 357 | 0.36 / 391.27 | 6 | 8 |
2 | 7 | 2001.44 | 106 | 11.74 | 1674 | 2083 | 2.44 / 393.35 | 8 | 25 |
3 | 13 | 1902.92 | 36 | 12.92 | 1634 | 760 | 3.20 / 394.11 | 6 | 35 |
4 | 13 | 1361.72 | 36 | 13.36 | 1291 | 621 | 3.82 / 394.73 | 6 | 44 |
5 | 13 | 815.36 | 36 | 13.71 | 913 | 451 | 4.27 / 395.18 | 6 | 49 |
6 | 13 | 160.28 | 36 | 14.33 | 416 | 215 | 4.49 / 395.40 | 6 | 32 |
7 | 8 | 0.08 | 450 | 14.23 | 288 | 1844 | 6.33 / 397.24 | 6 | 54 |
Average= | 6.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 69 | 14.42 | 355 | 353 | 0.35 / 385.08 | 6 | 8 |
2 | 7 | 2008.96 | 105 | 11.78 | 1678 | 2076 | 2.43 / 387.16 | 8 | 25 |
3 | 13 | 1710.04 | 36 | 13.10 | 1519 | 716 | 3.15 / 387.88 | 6 | 38 |
4 | 13 | 1396.48 | 36 | 13.36 | 1312 | 631 | 3.78 / 388.51 | 6 | 44 |
5 | 13 | 737.36 | 36 | 13.79 | 855 | 424 | 4.20 / 388.93 | 6 | 49 |
6 | 13 | 105.20 | 36 | 14.39 | 368 | 191 | 4.39 / 389.12 | 6 | 32 |
7 | 8 | 0.00 | 450 | 14.26 | 279 | 1790 | 6.18 / 390.91 | 6 | 50 |
Average= | 6.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 69 | 14.42 | 359 | 357 | 0.36 / 378.85 | 6 | 8 |
2 | 7 | 2002.20 | 105 | 11.88 | 1673 | 2087 | 2.44 / 380.94 | 8 | 26 |
3 | 13 | 1702.04 | 36 | 13.15 | 1511 | 715 | 3.16 / 381.65 | 6 | 38 |
4 | 13 | 1283.84 | 36 | 13.43 | 1244 | 601 | 3.76 / 382.26 | 6 | 45 |
5 | 13 | 753.00 | 36 | 13.78 | 871 | 432 | 4.19 / 382.69 | 6 | 49 |
6 | 13 | 105.60 | 36 | 14.39 | 378 | 196 | 4.39 / 382.88 | 6 | 31 |
7 | 8 | 0.12 | 450 | 14.25 | 288 | 1847 | 6.24 / 384.73 | 6 | 47 |
Average= | 6.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 69 | 14.46 | 349 | 348 | 0.35 / 372.60 | 6 | 8 |
2 | 7 | 2008.76 | 106 | 11.90 | 1684 | 2124 | 2.47 / 374.72 | 8 | 26 |
3 | 13 | 1908.40 | 36 | 12.96 | 1639 | 765 | 3.24 / 375.48 | 6 | 35 |
4 | 13 | 1175.36 | 36 | 13.51 | 1164 | 566 | 3.80 / 376.05 | 6 | 46 |
5 | 13 | 655.56 | 36 | 13.88 | 789 | 394 | 4.20 / 376.44 | 6 | 46 |
6 | 13 | 127.88 | 36 | 14.38 | 393 | 203 | 4.40 / 376.65 | 6 | 31 |
7 | 8 | 0.08 | 450 | 14.25 | 288 | 1847 | 6.25 / 378.49 | 6 | 51 |
Average= | 6.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 69 | 14.46 | 356 | 355 | 0.36 / 366.36 | 6 | 8 |
2 | 7 | 2006.60 | 105 | 11.96 | 1679 | 2108 | 2.46 / 368.47 | 8 | 26 |
3 | 13 | 1909.20 | 36 | 12.99 | 1640 | 767 | 3.23 / 369.24 | 6 | 35 |
4 | 13 | 1362.48 | 36 | 13.41 | 1290 | 623 | 3.85 / 369.86 | 6 | 44 |
5 | 13 | 714.04 | 36 | 13.84 | 832 | 415 | 4.27 / 370.28 | 6 | 48 |
6 | 13 | 85.64 | 36 | 14.42 | 351 | 182 | 4.45 / 370.46 | 6 | 31 |
7 | 8 | 0.08 | 450 | 14.25 | 279 | 1789 | 6.24 / 372.25 | 6 | 53 |
Average= | 6.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 68 | 14.46 | 355 | 349 | 0.35 / 360.16 | 6 | 7 |
2 | 7 | 2009.68 | 105 | 12.03 | 1679 | 2121 | 2.47 / 362.28 | 6 | 26 |
3 | 13 | 1908.84 | 36 | 13.02 | 1641 | 769 | 3.24 / 363.05 | 6 | 35 |
4 | 13 | 1172.44 | 36 | 13.54 | 1164 | 567 | 3.81 / 363.62 | 6 | 46 |
5 | 13 | 757.68 | 36 | 13.82 | 865 | 430 | 4.24 / 364.05 | 6 | 47 |
6 | 13 | 119.16 | 36 | 14.41 | 374 | 194 | 4.43 / 364.24 | 6 | 31 |
7 | 8 | 0.04 | 450 | 14.28 | 275 | 1767 | 6.20 / 366.01 | 6 | 50 |
Average= | 6.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 68 | 14.47 | 343 | 337 | 0.34 / 353.87 | 6 | 7 |
2 | 7 | 2008.28 | 105 | 12.08 | 1680 | 2131 | 2.47 / 356.00 | 6 | 26 |
3 | 13 | 1812.64 | 36 | 13.17 | 1574 | 746 | 3.21 / 356.75 | 6 | 36 |
4 | 13 | 1268.96 | 36 | 13.51 | 1223 | 595 | 3.81 / 357.34 | 6 | 44 |
5 | 13 | 731.36 | 36 | 13.87 | 842 | 420 | 4.23 / 357.76 | 6 | 45 |
6 | 13 | 182.68 | 36 | 14.36 | 431 | 223 | 4.45 / 357.99 | 6 | 32 |
7 | 8 | -0.04 | 450 | 14.27 | 284 | 1824 | 6.28 / 359.81 | 6 | 47 |
Average= | 6.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 68 | 14.48 | 353 | 348 | 0.35 / 347.58 | 6 | 8 |
2 | 7 | 2007.32 | 105 | 12.14 | 1679 | 2140 | 2.49 / 349.72 | 8 | 27 |
3 | 13 | 1799.88 | 36 | 13.18 | 1573 | 746 | 3.23 / 350.47 | 6 | 36 |
4 | 13 | 1081.16 | 36 | 13.61 | 1109 | 543 | 3.78 / 351.01 | 6 | 46 |
5 | 13 | 767.08 | 36 | 13.85 | 870 | 434 | 4.21 / 351.45 | 6 | 47 |
6 | 13 | 100.36 | 36 | 14.44 | 357 | 186 | 4.40 / 351.63 | 6 | 30 |
7 | 13 | 10.40 | 36 | 14.50 | 288 | 150 | 4.55 / 351.78 | 6 | 29 |
8 | 8 | 0.12 | 450 | 14.25 | 273 | 1751 | 6.30 / 353.53 | 6 | 57 |
Average= | 6.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 68 | 14.51 | 352 | 347 | 0.35 / 341.42 | 6 | 7 |
2 | 7 | 2009.00 | 105 | 12.20 | 1680 | 2152 | 2.50 / 343.57 | 6 | 26 |
3 | 13 | 1802.84 | 36 | 13.21 | 1570 | 747 | 3.25 / 344.32 | 6 | 36 |
4 | 13 | 1159.84 | 36 | 13.59 | 1153 | 564 | 3.81 / 344.88 | 6 | 47 |
5 | 13 | 733.44 | 36 | 13.87 | 846 | 422 | 4.23 / 345.30 | 6 | 47 |
6 | 13 | 90.64 | 36 | 14.46 | 350 | 182 | 4.41 / 345.49 | 6 | 30 |
7 | 8 | 0.08 | 450 | 14.30 | 272 | 1750 | 6.17 / 347.24 | 6 | 53 |
Average= | 6.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 68 | 14.52 | 338 | 334 | 0.33 / 335.03 | 6 | 7 |
2 | 7 | 2002.72 | 106 | 12.25 | 1679 | 2180 | 2.51 / 337.21 | 7 | 28 |
3 | 13 | 1903.24 | 36 | 13.14 | 1626 | 769 | 3.28 / 337.98 | 6 | 37 |
4 | 13 | 1247.52 | 36 | 13.55 | 1221 | 596 | 3.88 / 338.58 | 6 | 46 |
5 | 13 | 601.16 | 36 | 14.01 | 738 | 372 | 4.25 / 338.95 | 6 | 43 |
6 | 13 | 85.80 | 36 | 14.47 | 340 | 177 | 4.43 / 339.13 | 6 | 30 |
7 | 13 | 3.80 | 36 | 14.51 | 279 | 146 | 4.57 / 339.27 | 6 | 26 |
8 | 8 | 0.16 | 450 | 14.26 | 280 | 1797 | 6.37 / 341.07 | 6 | 59 |
Average= | 6.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 68 | 14.52 | 344 | 340 | 0.34 / 328.87 | 6 | 7 |
2 | 7 | 2010.92 | 106 | 12.31 | 1684 | 2197 | 2.54 / 331.07 | 7 | 28 |
3 | 13 | 1807.56 | 36 | 13.27 | 1578 | 754 | 3.29 / 331.82 | 6 | 37 |
4 | 13 | 1164.00 | 36 | 13.62 | 1152 | 565 | 3.86 / 332.39 | 6 | 46 |
5 | 13 | 638.84 | 36 | 13.99 | 768 | 387 | 4.24 / 332.77 | 6 | 46 |
6 | 13 | 95.08 | 36 | 14.47 | 351 | 183 | 4.43 / 332.95 | 6 | 31 |
7 | 8 | 0.12 | 450 | 14.31 | 271 | 1745 | 6.17 / 334.70 | 6 | 53 |
Average= | 6.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 68 | 14.52 | 345 | 341 | 0.34 / 322.65 | 6 | 7 |
2 | 7 | 2011.00 | 105 | 12.38 | 1684 | 2189 | 2.53 / 324.84 | 7 | 28 |
3 | 13 | 1809.96 | 36 | 13.28 | 1575 | 753 | 3.28 / 325.59 | 6 | 37 |
4 | 13 | 1171.92 | 36 | 13.63 | 1165 | 572 | 3.85 / 326.16 | 6 | 46 |
5 | 13 | 645.88 | 36 | 13.99 | 775 | 390 | 4.24 / 326.55 | 6 | 45 |
6 | 13 | 96.60 | 36 | 14.47 | 349 | 182 | 4.43 / 326.73 | 6 | 31 |
7 | 8 | 0.00 | 450 | 14.31 | 279 | 1797 | 6.22 / 328.53 | 6 | 55 |
Average= | 6.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 68 | 14.54 | 345 | 341 | 0.34 / 316.27 | 6 | 7 |
2 | 7 | 2009.48 | 105 | 12.44 | 1685 | 2201 | 2.54 / 318.47 | 7 | 29 |
3 | 13 | 1814.00 | 36 | 13.30 | 1586 | 759 | 3.30 / 319.23 | 6 | 37 |
4 | 13 | 1172.92 | 36 | 13.64 | 1165 | 572 | 3.87 / 319.80 | 6 | 46 |
5 | 13 | 548.20 | 36 | 14.08 | 699 | 354 | 4.23 / 320.16 | 6 | 43 |
6 | 13 | 118.32 | 36 | 14.45 | 370 | 192 | 4.42 / 320.35 | 6 | 30 |
7 | 13 | 13.48 | 36 | 14.54 | 288 | 151 | 4.57 / 320.50 | 6 | 29 |
8 | 8 | 0.00 | 450 | 14.28 | 281 | 1806 | 6.38 / 322.31 | 6 | 60 |
Average= | 6.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 68 | 14.51 | 354 | 349 | 0.35 / 310.05 | 6 | 6 |
2 | 7 | 2009.08 | 105 | 12.51 | 1683 | 2211 | 2.56 / 312.26 | 6 | 28 |
3 | 13 | 1911.00 | 36 | 13.25 | 1640 | 782 | 3.34 / 313.04 | 6 | 36 |
4 | 13 | 1059.52 | 36 | 13.72 | 1084 | 535 | 3.88 / 313.58 | 6 | 47 |
5 | 13 | 742.92 | 36 | 13.93 | 851 | 427 | 4.30 / 314.00 | 6 | 47 |
6 | 13 | 89.80 | 36 | 14.48 | 355 | 185 | 4.49 / 314.19 | 6 | 32 |
7 | 8 | -0.04 | 450 | 14.33 | 270 | 1741 | 6.23 / 315.93 | 6 | 53 |
Average= | 6.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 68 | 14.55 | 350 | 346 | 0.35 / 303.54 | 6 | 7 |
2 | 7 | 2003.88 | 105 | 12.55 | 1672 | 2203 | 2.55 / 305.75 | 6 | 28 |
3 | 13 | 1903.92 | 36 | 13.27 | 1634 | 781 | 3.33 / 306.53 | 6 | 36 |
4 | 13 | 1357.96 | 36 | 13.58 | 1291 | 631 | 3.96 / 307.16 | 6 | 46 |
5 | 13 | 585.60 | 36 | 14.05 | 729 | 369 | 4.33 / 307.53 | 6 | 44 |
6 | 13 | 152.76 | 36 | 14.44 | 395 | 205 | 4.54 / 307.73 | 6 | 33 |
7 | 13 | 29.36 | 36 | 14.52 | 310 | 162 | 4.70 / 307.89 | 6 | 30 |
8 | 8 | -0.08 | 450 | 14.28 | 281 | 1806 | 6.50 / 309.70 | 6 | 60 |
Average= | 6.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 67 | 14.55 | 344 | 335 | 0.34 / 297.15 | 6 | 7 |
2 | 7 | 2002.52 | 106 | 12.58 | 1676 | 2235 | 2.57 / 299.39 | 6 | 28 |
3 | 13 | 1787.20 | 36 | 13.37 | 1557 | 749 | 3.32 / 300.14 | 6 | 38 |
4 | 13 | 1236.84 | 36 | 13.65 | 1207 | 593 | 3.91 / 300.73 | 6 | 46 |
5 | 13 | 484.08 | 36 | 14.14 | 650 | 331 | 4.24 / 301.06 | 6 | 41 |
6 | 13 | 80.60 | 36 | 14.51 | 335 | 175 | 4.42 / 301.24 | 6 | 31 |
7 | 13 | 20.28 | 36 | 14.51 | 292 | 153 | 4.57 / 301.39 | 6 | 30 |
8 | 8 | 0.04 | 450 | 14.29 | 281 | 1807 | 6.38 / 303.20 | 6 | 67 |
Average= | 6.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 67 | 14.57 | 339 | 331 | 0.33 / 290.86 | 6 | 6 |
2 | 7 | 2012.16 | 105 | 12.55 | 1686 | 2222 | 2.55 / 293.08 | 6 | 28 |
3 | 13 | 1612.68 | 36 | 13.45 | 1452 | 703 | 3.26 / 293.79 | 6 | 39 |
4 | 13 | 1195.24 | 36 | 13.66 | 1180 | 580 | 3.84 / 294.37 | 6 | 47 |
5 | 13 | 558.76 | 36 | 14.09 | 708 | 359 | 4.20 / 294.72 | 6 | 43 |
6 | 13 | 116.48 | 36 | 14.47 | 368 | 192 | 4.39 / 294.92 | 6 | 31 |
7 | 13 | 27.84 | 36 | 14.53 | 299 | 156 | 4.54 / 295.07 | 6 | 31 |
8 | 8 | 0.08 | 450 | 14.31 | 271 | 1745 | 6.29 / 296.82 | 6 | 58 |
Average= | 6.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 67 | 14.59 | 334 | 326 | 0.33 / 284.60 | 6 | 6 |
2 | 7 | 2008.88 | 105 | 12.52 | 1685 | 2215 | 2.54 / 286.81 | 6 | 28 |
3 | 13 | 1604.84 | 36 | 13.45 | 1441 | 698 | 3.24 / 287.51 | 6 | 39 |
4 | 13 | 1187.20 | 36 | 13.67 | 1170 | 576 | 3.82 / 288.08 | 6 | 46 |
5 | 13 | 557.52 | 36 | 14.08 | 709 | 359 | 4.17 / 288.44 | 6 | 43 |
6 | 13 | 70.28 | 36 | 14.51 | 335 | 175 | 4.35 / 288.62 | 6 | 31 |
7 | 13 | 37.76 | 36 | 14.46 | 307 | 160 | 4.51 / 288.78 | 6 | 30 |
8 | 8 | -0.08 | 450 | 14.31 | 272 | 1752 | 6.26 / 290.53 | 6 | 57 |
Average= | 6.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 67 | 14.57 | 341 | 333 | 0.33 / 278.21 | 6 | 6 |
2 | 7 | 2009.00 | 105 | 12.51 | 1685 | 2213 | 2.55 / 280.42 | 6 | 28 |
3 | 13 | 1704.60 | 36 | 13.40 | 1509 | 728 | 3.27 / 281.15 | 6 | 39 |
4 | 13 | 1269.24 | 36 | 13.62 | 1233 | 605 | 3.88 / 281.75 | 6 | 46 |
5 | 13 | 709.72 | 36 | 13.96 | 832 | 418 | 4.30 / 282.17 | 6 | 48 |
6 | 13 | 77.80 | 36 | 14.51 | 339 | 177 | 4.47 / 282.35 | 6 | 32 |
7 | 13 | 22.12 | 36 | 14.51 | 299 | 156 | 4.63 / 282.50 | 6 | 30 |
8 | 8 | -0.04 | 450 | 14.31 | 274 | 1764 | 6.39 / 284.27 | 6 | 52 |
Average= | 6.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 67 | 14.56 | 343 | 335 | 0.33 / 271.85 | 6 | 6 |
2 | 7 | 2003.84 | 105 | 12.50 | 1685 | 2212 | 2.55 / 274.06 | 6 | 28 |
3 | 13 | 1803.40 | 36 | 13.33 | 1577 | 757 | 3.30 / 274.82 | 6 | 37 |
4 | 13 | 1071.96 | 36 | 13.71 | 1097 | 541 | 3.84 / 275.36 | 6 | 48 |
5 | 13 | 552.88 | 36 | 14.08 | 705 | 357 | 4.20 / 275.72 | 6 | 45 |
6 | 13 | 62.40 | 36 | 14.52 | 336 | 176 | 4.38 / 275.89 | 6 | 30 |
7 | 13 | 32.48 | 36 | 14.45 | 312 | 162 | 4.54 / 276.05 | 6 | 31 |
8 | 8 | 0.00 | 450 | 14.29 | 283 | 1820 | 6.36 / 277.87 | 6 | 57 |
Average= | 6.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 67 | 14.56 | 353 | 344 | 0.34 / 265.43 | 6 | 6 |
2 | 7 | 2013.36 | 105 | 12.50 | 1690 | 2218 | 2.56 / 267.65 | 6 | 29 |
3 | 13 | 1617.68 | 36 | 13.41 | 1462 | 706 | 3.27 / 268.36 | 6 | 41 |
4 | 13 | 1105.56 | 36 | 13.69 | 1124 | 554 | 3.82 / 268.91 | 6 | 47 |
5 | 13 | 669.44 | 36 | 13.98 | 804 | 405 | 4.23 / 269.32 | 6 | 48 |
6 | 13 | 103.80 | 36 | 14.48 | 364 | 190 | 4.42 / 269.51 | 6 | 32 |
7 | 13 | 24.00 | 36 | 14.51 | 312 | 163 | 4.58 / 269.67 | 6 | 31 |
8 | 8 | 0.00 | 450 | 14.29 | 287 | 1846 | 6.43 / 271.51 | 6 | 58 |
Average= | 6.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 67 | 14.57 | 354 | 346 | 0.35 / 258.97 | 6 | 6 |
2 | 7 | 2004.32 | 105 | 12.54 | 1681 | 2213 | 2.56 / 261.18 | 6 | 28 |
3 | 13 | 1803.76 | 36 | 13.34 | 1576 | 757 | 3.32 / 261.94 | 6 | 38 |
4 | 13 | 1156.20 | 36 | 13.67 | 1152 | 567 | 3.88 / 262.51 | 6 | 48 |
5 | 13 | 616.76 | 36 | 14.03 | 761 | 384 | 4.27 / 262.89 | 6 | 46 |
6 | 13 | 83.64 | 36 | 14.52 | 348 | 182 | 4.45 / 263.07 | 6 | 32 |
7 | 13 | 19.40 | 36 | 14.52 | 301 | 157 | 4.61 / 263.23 | 6 | 33 |
8 | 8 | 0.04 | 450 | 14.29 | 289 | 1858 | 6.46 / 265.09 | 6 | 61 |
Average= | 6.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 67 | 14.57 | 349 | 341 | 0.34 / 252.64 | 6 | 6 |
2 | 7 | 2009.40 | 106 | 12.55 | 1687 | 2244 | 2.58 / 254.89 | 6 | 28 |
3 | 13 | 1506.48 | 36 | 13.48 | 1390 | 675 | 3.26 / 255.56 | 6 | 41 |
4 | 13 | 1092.64 | 36 | 13.71 | 1115 | 550 | 3.81 / 256.11 | 6 | 47 |
5 | 13 | 459.72 | 36 | 14.19 | 639 | 326 | 4.14 / 256.44 | 6 | 41 |
6 | 13 | 64.84 | 36 | 14.53 | 338 | 177 | 4.31 / 256.61 | 6 | 30 |
7 | 13 | 14.20 | 36 | 14.51 | 304 | 159 | 4.47 / 256.77 | 6 | 32 |
8 | 8 | -0.08 | 450 | 14.29 | 288 | 1852 | 6.32 / 258.62 | 6 | 58 |
Average= | 6.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 67 | 14.58 | 351 | 343 | 0.34 / 246.27 | 6 | 6 |
2 | 7 | 2008.52 | 105 | 12.59 | 1681 | 2222 | 2.57 / 248.49 | 6 | 28 |
3 | 13 | 1706.64 | 36 | 13.42 | 1511 | 730 | 3.30 / 249.22 | 6 | 39 |
4 | 13 | 1166.80 | 36 | 13.69 | 1158 | 571 | 3.87 / 249.79 | 6 | 46 |
5 | 13 | 620.68 | 36 | 14.06 | 758 | 384 | 4.25 / 250.18 | 6 | 46 |
6 | 13 | 49.60 | 36 | 14.57 | 320 | 168 | 4.42 / 250.34 | 6 | 31 |
7 | 13 | 12.24 | 36 | 14.51 | 294 | 154 | 4.57 / 250.50 | 6 | 30 |
8 | 8 | -0.04 | 450 | 14.31 | 280 | 1803 | 6.37 / 252.30 | 6 | 60 |
Average= | 6.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 67 | 14.59 | 344 | 336 | 0.34 / 239.91 | 6 | 6 |
2 | 7 | 2007.16 | 105 | 12.63 | 1682 | 2231 | 2.57 / 242.14 | 6 | 28 |
3 | 13 | 1696.08 | 36 | 13.44 | 1512 | 732 | 3.30 / 242.87 | 6 | 38 |
4 | 13 | 1160.68 | 36 | 13.71 | 1156 | 571 | 3.87 / 243.44 | 6 | 47 |
5 | 13 | 625.76 | 36 | 14.08 | 760 | 385 | 4.25 / 243.82 | 6 | 45 |
6 | 13 | 87.84 | 36 | 14.55 | 344 | 180 | 4.43 / 244.00 | 6 | 31 |
7 | 13 | 21.32 | 36 | 14.56 | 296 | 155 | 4.59 / 244.16 | 6 | 29 |
8 | 8 | 0.04 | 450 | 14.34 | 274 | 1768 | 6.36 / 245.93 | 6 | 58 |
Average= | 6.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 67 | 14.60 | 351 | 343 | 0.34 / 233.58 | 6 | 6 |
2 | 7 | 2003.16 | 105 | 12.65 | 1681 | 2233 | 2.58 / 235.82 | 6 | 28 |
3 | 13 | 1605.40 | 36 | 13.49 | 1452 | 705 | 3.28 / 236.52 | 6 | 40 |
4 | 13 | 1188.80 | 36 | 13.71 | 1180 | 582 | 3.86 / 237.10 | 6 | 46 |
5 | 13 | 543.56 | 36 | 14.16 | 702 | 358 | 4.22 / 237.46 | 6 | 43 |
6 | 13 | 54.32 | 36 | 14.58 | 323 | 170 | 4.39 / 237.63 | 6 | 30 |
7 | 13 | 27.52 | 36 | 14.50 | 302 | 158 | 4.55 / 237.79 | 6 | 30 |
8 | 8 | -0.04 | 450 | 14.34 | 276 | 1781 | 6.33 / 239.57 | 6 | 62 |
Average= | 5.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 67 | 14.61 | 344 | 337 | 0.34 / 227.13 | 6 | 7 |
2 | 7 | 2005.92 | 105 | 12.68 | 1686 | 2245 | 2.58 / 229.37 | 7 | 29 |
3 | 13 | 1704.92 | 36 | 13.47 | 1517 | 736 | 3.32 / 230.11 | 6 | 40 |
4 | 13 | 1172.32 | 36 | 13.74 | 1165 | 576 | 3.89 / 230.68 | 6 | 47 |
5 | 13 | 622.00 | 36 | 14.10 | 762 | 387 | 4.28 / 231.07 | 6 | 45 |
6 | 13 | 83.04 | 36 | 14.57 | 340 | 178 | 4.46 / 231.25 | 6 | 31 |
7 | 13 | 3.88 | 36 | 14.60 | 292 | 153 | 4.61 / 231.40 | 6 | 24 |
8 | 8 | 0.04 | 450 | 14.34 | 285 | 1839 | 6.45 / 233.24 | 6 | 56 |
Average= | 5.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 67 | 14.60 | 357 | 349 | 0.35 / 220.61 | 6 | 7 |
2 | 7 | 2012.08 | 106 | 12.72 | 1689 | 2277 | 2.63 / 222.89 | 6 | 30 |
3 | 13 | 1809.68 | 36 | 13.45 | 1589 | 769 | 3.40 / 223.66 | 6 | 39 |
4 | 13 | 1147.12 | 36 | 13.76 | 1147 | 568 | 3.96 / 224.23 | 6 | 48 |
5 | 13 | 597.24 | 36 | 14.13 | 745 | 379 | 4.34 / 224.61 | 6 | 46 |
6 | 13 | 69.52 | 36 | 14.58 | 337 | 177 | 4.52 / 224.78 | 6 | 31 |
7 | 13 | 1.32 | 36 | 14.61 | 294 | 155 | 4.67 / 224.94 | 6 | 26 |
8 | 8 | 0.04 | 450 | 14.33 | 287 | 1851 | 6.53 / 226.79 | 6 | 56 |
Average= | 5.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 67 | 14.60 | 348 | 340 | 0.34 / 214.38 | 6 | 7 |
2 | 7 | 2005.72 | 105 | 12.78 | 1687 | 2264 | 2.60 / 216.64 | 6 | 31 |
3 | 13 | 1603.52 | 36 | 13.56 | 1454 | 710 | 3.31 / 217.35 | 6 | 41 |
4 | 13 | 1173.24 | 36 | 13.78 | 1164 | 577 | 3.89 / 217.93 | 6 | 47 |
5 | 13 | 433.56 | 36 | 14.29 | 615 | 316 | 4.21 / 218.24 | 6 | 39 |
6 | 13 | 55.72 | 36 | 14.61 | 335 | 176 | 4.38 / 218.42 | 6 | 29 |
7 | 8 | 0.12 | 450 | 14.37 | 285 | 1843 | 6.23 / 220.26 | 6 | 52 |
Average= | 5.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 67 | 14.59 | 361 | 353 | 0.35 / 208.10 | 6 | 7 |
2 | 7 | 2013.72 | 105 | 12.81 | 1689 | 2272 | 2.62 / 210.37 | 6 | 30 |
3 | 13 | 1713.04 | 36 | 13.55 | 1526 | 744 | 3.37 / 211.12 | 6 | 40 |
4 | 13 | 1167.60 | 36 | 13.79 | 1167 | 579 | 3.95 / 211.70 | 6 | 47 |
5 | 13 | 519.00 | 36 | 14.23 | 683 | 350 | 4.30 / 212.05 | 6 | 42 |
6 | 13 | 85.72 | 36 | 14.60 | 348 | 183 | 4.48 / 212.23 | 6 | 30 |
7 | 8 | 0.08 | 450 | 14.38 | 279 | 1805 | 6.29 / 214.04 | 6 | 56 |
Average= | 5.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 67 | 14.60 | 351 | 343 | 0.34 / 201.89 | 6 | 8 |
2 | 7 | 2008.84 | 105 | 12.85 | 1691 | 2282 | 2.62 / 204.17 | 6 | 30 |
3 | 13 | 1593.12 | 36 | 13.61 | 1447 | 709 | 3.33 / 204.88 | 6 | 41 |
4 | 13 | 988.04 | 36 | 13.90 | 1035 | 518 | 3.85 / 205.40 | 6 | 48 |
5 | 13 | 473.12 | 36 | 14.30 | 642 | 331 | 4.18 / 205.73 | 6 | 40 |
6 | 13 | 71.32 | 36 | 14.63 | 330 | 174 | 4.36 / 205.90 | 6 | 30 |
7 | 8 | 0.04 | 450 | 14.39 | 285 | 1846 | 6.20 / 207.75 | 6 | 57 |
Average= | 5.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 67 | 14.60 | 352 | 344 | 0.34 / 195.64 | 6 | 8 |
2 | 7 | 2002.36 | 106 | 12.88 | 1685 | 2300 | 2.64 / 197.94 | 8 | 31 |
3 | 13 | 1694.08 | 36 | 13.59 | 1507 | 737 | 3.38 / 198.68 | 6 | 41 |
4 | 13 | 1052.96 | 36 | 13.88 | 1083 | 541 | 3.92 / 199.22 | 6 | 48 |
5 | 13 | 526.88 | 36 | 14.26 | 688 | 353 | 4.28 / 199.58 | 6 | 42 |
6 | 13 | 94.56 | 36 | 14.62 | 348 | 183 | 4.46 / 199.76 | 6 | 31 |
7 | 8 | 0.16 | 450 | 14.40 | 276 | 1788 | 6.25 / 201.55 | 6 | 51 |
Average= | 5.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 67 | 14.58 | 369 | 360 | 0.36 / 189.32 | 6 | 9 |
2 | 7 | 2009.56 | 105 | 12.90 | 1694 | 2295 | 2.65 / 191.61 | 9 | 31 |
3 | 13 | 1707.96 | 36 | 13.60 | 1524 | 746 | 3.40 / 192.36 | 6 | 41 |
4 | 13 | 1272.24 | 36 | 13.79 | 1233 | 612 | 4.01 / 192.97 | 6 | 47 |
5 | 13 | 498.84 | 36 | 14.29 | 667 | 343 | 4.36 / 193.32 | 6 | 41 |
6 | 13 | 84.48 | 36 | 14.64 | 345 | 182 | 4.54 / 193.50 | 6 | 30 |
7 | 8 | 0.00 | 450 | 14.41 | 278 | 1803 | 6.34 / 195.30 | 6 | 54 |
Average= | 5.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 67 | 14.59 | 362 | 354 | 0.35 / 182.97 | 6 | 8 |
2 | 7 | 2007.92 | 105 | 12.93 | 1691 | 2296 | 2.65 / 185.26 | 8 | 31 |
3 | 13 | 1704.08 | 36 | 13.62 | 1521 | 746 | 3.40 / 186.01 | 6 | 41 |
4 | 13 | 1153.44 | 36 | 13.85 | 1153 | 575 | 3.97 / 186.58 | 6 | 48 |
5 | 13 | 506.92 | 36 | 14.29 | 672 | 346 | 4.32 / 186.93 | 6 | 42 |
6 | 13 | 41.68 | 36 | 14.66 | 325 | 172 | 4.49 / 187.10 | 6 | 30 |
7 | 8 | 0.08 | 450 | 14.39 | 287 | 1858 | 6.35 / 188.96 | 6 | 50 |
Average= | 5.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 67 | 14.60 | 366 | 358 | 0.36 / 176.56 | 6 | 8 |
2 | 7 | 2012.60 | 105 | 12.96 | 1691 | 2301 | 2.66 / 178.87 | 8 | 31 |
3 | 13 | 1809.68 | 36 | 13.59 | 1584 | 775 | 3.43 / 179.64 | 6 | 40 |
4 | 13 | 1054.44 | 36 | 13.91 | 1084 | 543 | 3.98 / 180.18 | 6 | 49 |
5 | 13 | 617.72 | 36 | 14.22 | 757 | 388 | 4.36 / 180.57 | 6 | 44 |
6 | 13 | 83.08 | 36 | 14.65 | 356 | 188 | 4.55 / 180.76 | 6 | 29 |
7 | 8 | 0.00 | 450 | 14.41 | 286 | 1855 | 6.41 / 182.61 | 6 | 50 |
Average= | 5.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 67 | 14.60 | 361 | 353 | 0.35 / 170.24 | 6 | 8 |
2 | 7 | 2008.04 | 105 | 13.01 | 1690 | 2309 | 2.66 / 172.54 | 8 | 31 |
3 | 13 | 1700.24 | 36 | 13.65 | 1517 | 745 | 3.41 / 173.29 | 6 | 41 |
4 | 13 | 1056.60 | 36 | 13.92 | 1090 | 546 | 3.95 / 173.84 | 6 | 48 |
5 | 13 | 623.68 | 36 | 14.23 | 758 | 388 | 4.34 / 174.22 | 6 | 45 |
6 | 13 | 5.96 | 36 | 14.71 | 290 | 154 | 4.50 / 174.38 | 6 | 30 |
7 | 8 | 0.08 | 450 | 14.41 | 282 | 1829 | 6.32 / 176.21 | 6 | 53 |
Average= | 5.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 67 | 14.60 | 361 | 353 | 0.35 / 163.93 | 6 | 8 |
2 | 7 | 2003.28 | 106 | 13.02 | 1688 | 2330 | 2.68 / 166.26 | 8 | 32 |
3 | 13 | 1794.84 | 36 | 13.62 | 1569 | 769 | 3.45 / 167.03 | 6 | 40 |
4 | 13 | 928.32 | 36 | 13.99 | 996 | 502 | 3.95 / 167.53 | 6 | 48 |
5 | 13 | 414.76 | 36 | 14.40 | 601 | 312 | 4.27 / 167.84 | 6 | 37 |
6 | 13 | 23.16 | 36 | 14.70 | 314 | 166 | 4.43 / 168.01 | 6 | 28 |
7 | 8 | 0.04 | 450 | 14.40 | 289 | 1873 | 6.30 / 169.88 | 6 | 51 |
Average= | 5.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 67 | 14.62 | 340 | 333 | 0.33 / 157.62 | 6 | 8 |
2 | 7 | 2003.32 | 105 | 13.04 | 1685 | 2307 | 2.64 / 159.92 | 8 | 31 |
3 | 13 | 1578.16 | 36 | 13.70 | 1441 | 711 | 3.35 / 160.63 | 6 | 42 |
4 | 13 | 1048.32 | 36 | 13.94 | 1083 | 543 | 3.89 / 161.18 | 6 | 48 |
5 | 13 | 602.96 | 36 | 14.25 | 743 | 381 | 4.28 / 161.56 | 6 | 45 |
6 | 13 | 33.24 | 36 | 14.70 | 315 | 167 | 4.44 / 161.73 | 6 | 30 |
7 | 8 | 0.04 | 450 | 14.39 | 286 | 1852 | 6.29 / 163.58 | 6 | 60 |
Average= | 5.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 67 | 14.61 | 359 | 351 | 0.35 / 151.36 | 6 | 8 |
2 | 7 | 2003.04 | 105 | 13.07 | 1691 | 2321 | 2.67 / 153.69 | 8 | 31 |
3 | 13 | 1598.08 | 36 | 13.71 | 1451 | 716 | 3.39 / 154.40 | 6 | 42 |
4 | 13 | 1055.08 | 36 | 13.94 | 1088 | 546 | 3.93 / 154.95 | 6 | 49 |
5 | 13 | 516.04 | 36 | 14.33 | 675 | 348 | 4.28 / 155.30 | 6 | 41 |
6 | 13 | 84.60 | 36 | 14.68 | 346 | 183 | 4.47 / 155.48 | 6 | 29 |
7 | 8 | 0.04 | 450 | 14.43 | 278 | 1805 | 6.27 / 157.28 | 6 | 57 |
Average= | 5.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 67 | 14.59 | 365 | 357 | 0.36 / 145.09 | 6 | 9 |
2 | 7 | 2009.44 | 105 | 13.09 | 1694 | 2328 | 2.69 / 147.42 | 9 | 31 |
3 | 13 | 1699.96 | 36 | 13.68 | 1510 | 744 | 3.43 / 148.16 | 6 | 41 |
4 | 13 | 1038.92 | 36 | 13.96 | 1077 | 541 | 3.97 / 148.70 | 6 | 48 |
5 | 13 | 397.88 | 36 | 14.45 | 587 | 305 | 4.28 / 149.01 | 6 | 35 |
6 | 13 | 90.20 | 36 | 14.68 | 350 | 185 | 4.46 / 149.19 | 6 | 28 |
7 | 8 | 0.20 | 450 | 14.44 | 280 | 1819 | 6.28 / 151.01 | 6 | 58 |
Average= | 5.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 67 | 14.60 | 357 | 349 | 0.35 / 138.94 | 6 | 8 |
2 | 7 | 2006.04 | 105 | 13.09 | 1693 | 2327 | 2.68 / 141.27 | 8 | 31 |
3 | 13 | 1601.64 | 36 | 13.71 | 1449 | 715 | 3.39 / 141.98 | 6 | 42 |
4 | 13 | 1070.04 | 36 | 13.94 | 1099 | 552 | 3.94 / 142.54 | 6 | 48 |
5 | 13 | 440.44 | 36 | 14.41 | 618 | 321 | 4.26 / 142.86 | 6 | 38 |
6 | 8 | 0.24 | 450 | 14.43 | 289 | 1877 | 6.14 / 144.73 | 6 | 50 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 67 | 14.61 | 362 | 354 | 0.35 / 132.70 | 6 | 8 |
2 | 7 | 2006.00 | 106 | 13.10 | 1692 | 2350 | 2.70 / 135.05 | 8 | 31 |
3 | 13 | 1691.96 | 36 | 13.69 | 1510 | 744 | 3.45 / 135.80 | 6 | 41 |
4 | 13 | 942.96 | 36 | 14.02 | 1007 | 508 | 3.96 / 136.30 | 6 | 48 |
5 | 13 | 427.92 | 36 | 14.43 | 610 | 317 | 4.27 / 136.62 | 6 | 36 |
6 | 13 | 22.80 | 36 | 14.73 | 303 | 161 | 4.43 / 136.78 | 6 | 28 |
7 | 8 | -0.16 | 450 | 14.43 | 279 | 1812 | 6.25 / 138.59 | 6 | 57 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 67 | 14.62 | 357 | 350 | 0.35 / 126.35 | 6 | 8 |
2 | 7 | 2001.56 | 105 | 13.11 | 1687 | 2322 | 2.67 / 128.67 | 8 | 31 |
3 | 13 | 1694.44 | 36 | 13.69 | 1513 | 746 | 3.42 / 129.42 | 6 | 41 |
4 | 13 | 1031.88 | 36 | 13.97 | 1070 | 538 | 3.96 / 129.96 | 6 | 48 |
5 | 13 | 493.84 | 36 | 14.36 | 660 | 341 | 4.30 / 130.30 | 6 | 40 |
6 | 13 | 15.64 | 36 | 14.73 | 308 | 163 | 4.46 / 130.46 | 6 | 30 |
7 | 8 | 0.00 | 450 | 14.40 | 291 | 1886 | 6.35 / 132.35 | 6 | 58 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 65 | 14.61 | 356 | 338 | 0.34 / 120.14 | 6 | 8 |
2 | 3 | 1027.08 | 1 | 14.56 | 1069 | 16 | 0.35 / 120.15 | 6 | 23 |
3 | 7 | 2003.72 | 105 | 13.15 | 1688 | 2331 | 2.68 / 122.49 | 23 | 30 |
4 | 13 | 1684.00 | 36 | 13.70 | 1505 | 742 | 3.43 / 123.23 | 6 | 40 |
5 | 13 | 1046.84 | 36 | 13.98 | 1082 | 545 | 3.97 / 123.77 | 6 | 47 |
6 | 13 | 410.56 | 36 | 14.46 | 594 | 309 | 4.28 / 124.08 | 6 | 34 |
7 | 13 | 45.60 | 36 | 14.75 | 311 | 165 | 4.45 / 124.25 | 6 | 27 |
8 | 8 | 0.16 | 450 | 14.45 | 270 | 1756 | 6.20 / 126.00 | 6 | 66 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.52 | 64 | 14.62 | 367 | 343 | 0.34 / 113.84 | 6 | 8 |
2 | 3 | 1026.88 | 1 | 14.58 | 1080 | 16 | 0.36 / 113.85 | 6 | 27 |
3 | 7 | 2002.96 | 105 | 13.15 | 1690 | 2333 | 2.69 / 116.18 | 27 | 31 |
4 | 13 | 1689.92 | 36 | 13.70 | 1508 | 744 | 3.44 / 116.93 | 6 | 41 |
5 | 13 | 1146.40 | 36 | 13.93 | 1150 | 577 | 4.01 / 117.50 | 6 | 47 |
6 | 13 | 394.84 | 36 | 14.48 | 581 | 303 | 4.32 / 117.81 | 6 | 32 |
7 | 13 | 85.92 | 36 | 14.72 | 338 | 179 | 4.50 / 117.99 | 6 | 28 |
8 | 8 | 0.12 | 450 | 14.45 | 279 | 1814 | 6.31 / 119.80 | 6 | 52 |
Average= | 5.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 64 | 14.65 | 348 | 326 | 0.33 / 107.50 | 6 | 7 |
2 | 7 | 2008.64 | 106 | 13.14 | 1694 | 2359 | 2.69 / 109.86 | 6 | 32 |
3 | 13 | 1696.08 | 36 | 13.68 | 1513 | 745 | 3.43 / 110.60 | 6 | 41 |
4 | 13 | 1037.08 | 36 | 13.97 | 1074 | 540 | 3.97 / 111.14 | 6 | 49 |
5 | 13 | 396.92 | 36 | 14.45 | 578 | 301 | 4.27 / 111.44 | 6 | 37 |
6 | 13 | 40.72 | 36 | 14.72 | 325 | 172 | 4.44 / 111.62 | 6 | 29 |
7 | 8 | 0.08 | 450 | 14.42 | 289 | 1875 | 6.32 / 113.49 | 6 | 59 |
Average= | 5.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 64 | 14.66 | 340 | 319 | 0.32 / 101.36 | 6 | 7 |
2 | 7 | 2003.68 | 105 | 13.16 | 1692 | 2338 | 2.66 / 103.69 | 6 | 32 |
3 | 13 | 1597.64 | 36 | 13.72 | 1456 | 719 | 3.38 / 104.41 | 6 | 42 |
4 | 13 | 961.92 | 36 | 14.01 | 1023 | 516 | 3.89 / 104.93 | 6 | 49 |
5 | 13 | 332.40 | 36 | 14.49 | 541 | 282 | 4.17 / 105.21 | 6 | 36 |
6 | 13 | 57.72 | 36 | 14.72 | 328 | 174 | 4.35 / 105.39 | 6 | 30 |
7 | 8 | 0.12 | 450 | 14.44 | 275 | 1787 | 6.14 / 107.17 | 6 | 55 |
Average= | 5.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 64 | 14.66 | 349 | 327 | 0.33 / 95.18 | 6 | 7 |
2 | 7 | 2005.72 | 105 | 13.17 | 1694 | 2343 | 2.67 / 97.52 | 7 | 32 |
3 | 13 | 1581.36 | 36 | 13.73 | 1444 | 714 | 3.38 / 98.23 | 6 | 43 |
4 | 13 | 1046.52 | 36 | 13.95 | 1087 | 546 | 3.93 / 98.78 | 6 | 49 |
5 | 13 | 397.08 | 36 | 14.43 | 585 | 304 | 4.23 / 99.08 | 6 | 39 |
6 | 13 | 82.16 | 36 | 14.69 | 343 | 181 | 4.41 / 99.26 | 6 | 32 |
7 | 8 | 0.08 | 450 | 14.44 | 273 | 1774 | 6.19 / 101.04 | 6 | 62 |
Average= | 5.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 64 | 14.66 | 346 | 325 | 0.32 / 88.99 | 6 | 7 |
2 | 7 | 2002.52 | 105 | 13.18 | 1695 | 2346 | 2.67 / 91.33 | 6 | 33 |
3 | 13 | 1584.72 | 36 | 13.73 | 1446 | 715 | 3.39 / 92.05 | 6 | 43 |
4 | 13 | 942.88 | 36 | 14.01 | 1014 | 511 | 3.90 / 92.56 | 6 | 49 |
5 | 13 | 420.32 | 36 | 14.41 | 607 | 315 | 4.21 / 92.87 | 6 | 40 |
6 | 13 | 46.36 | 36 | 14.73 | 320 | 170 | 4.38 / 93.04 | 6 | 32 |
7 | 8 | -0.04 | 450 | 14.44 | 278 | 1806 | 6.19 / 94.85 | 6 | 57 |
Average= | 5.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 63 | 14.69 | 348 | 322 | 0.32 / 82.72 | 6 | 7 |
2 | 7 | 2010.28 | 105 | 13.20 | 1700 | 2356 | 2.68 / 85.07 | 6 | 32 |
3 | 13 | 1590.08 | 36 | 13.74 | 1448 | 716 | 3.39 / 85.79 | 6 | 42 |
4 | 13 | 1056.64 | 36 | 13.97 | 1089 | 548 | 3.94 / 86.34 | 6 | 49 |
5 | 13 | 407.40 | 36 | 14.43 | 598 | 311 | 4.25 / 86.65 | 6 | 39 |
6 | 13 | 45.68 | 36 | 14.74 | 317 | 168 | 4.42 / 86.82 | 6 | 31 |
7 | 8 | 0.08 | 450 | 14.44 | 284 | 1845 | 6.27 / 88.66 | 6 | 55 |
Average= | 5.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 63 | 14.71 | 342 | 317 | 0.32 / 76.50 | 6 | 6 |
2 | 7 | 2007.84 | 105 | 13.22 | 1694 | 2351 | 2.67 / 78.85 | 6 | 32 |
3 | 13 | 1589.92 | 36 | 13.75 | 1448 | 717 | 3.39 / 79.56 | 6 | 42 |
4 | 13 | 948.96 | 36 | 14.03 | 1020 | 515 | 3.90 / 80.08 | 6 | 48 |
5 | 13 | 414.80 | 36 | 14.42 | 607 | 315 | 4.22 / 80.40 | 6 | 39 |
6 | 13 | 48.04 | 36 | 14.73 | 337 | 179 | 4.39 / 80.57 | 6 | 31 |
7 | 8 | 0.04 | 450 | 14.45 | 280 | 1821 | 6.21 / 82.39 | 6 | 52 |
Average= | 5.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 63 | 14.72 | 339 | 314 | 0.31 / 70.25 | 6 | 6 |
2 | 7 | 2011.00 | 105 | 13.22 | 1702 | 2363 | 2.68 / 72.61 | 6 | 33 |
3 | 13 | 1589.60 | 36 | 13.75 | 1447 | 716 | 3.39 / 73.33 | 6 | 42 |
4 | 13 | 1047.80 | 36 | 13.97 | 1089 | 548 | 3.94 / 73.88 | 6 | 48 |
5 | 13 | 500.00 | 36 | 14.34 | 675 | 348 | 4.29 / 74.23 | 6 | 43 |
6 | 13 | 44.40 | 36 | 14.76 | 317 | 168 | 4.46 / 74.40 | 6 | 30 |
7 | 8 | 0.08 | 450 | 14.47 | 274 | 1784 | 6.24 / 76.18 | 6 | 55 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 63 | 14.70 | 342 | 317 | 0.32 / 63.89 | 6 | 6 |
2 | 7 | 2008.04 | 105 | 13.25 | 1700 | 2365 | 2.68 / 66.25 | 6 | 33 |
3 | 13 | 1589.48 | 36 | 13.76 | 1449 | 718 | 3.40 / 66.97 | 6 | 42 |
4 | 13 | 948.52 | 36 | 14.02 | 1022 | 516 | 3.92 / 67.49 | 6 | 49 |
5 | 13 | 313.52 | 36 | 14.52 | 524 | 274 | 4.19 / 67.76 | 6 | 35 |
6 | 13 | 50.12 | 36 | 14.75 | 324 | 172 | 4.36 / 67.93 | 6 | 31 |
7 | 13 | 26.60 | 36 | 14.67 | 302 | 159 | 4.52 / 68.09 | 6 | 30 |
8 | 8 | -0.08 | 450 | 14.43 | 284 | 1844 | 6.37 / 69.94 | 6 | 61 |
Average= | 5.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 63 | 14.70 | 352 | 326 | 0.33 / 57.47 | 6 | 6 |
2 | 7 | 2011.44 | 105 | 13.25 | 1702 | 2368 | 2.69 / 59.84 | 6 | 33 |
3 | 13 | 1583.36 | 36 | 13.76 | 1444 | 715 | 3.41 / 60.55 | 6 | 42 |
4 | 13 | 946.24 | 36 | 14.04 | 1013 | 512 | 3.92 / 61.07 | 6 | 48 |
5 | 13 | 412.72 | 36 | 14.43 | 604 | 314 | 4.23 / 61.38 | 6 | 39 |
6 | 13 | 44.48 | 36 | 14.76 | 319 | 170 | 4.40 / 61.55 | 6 | 30 |
7 | 13 | 24.60 | 36 | 14.66 | 316 | 167 | 4.57 / 61.72 | 6 | 31 |
8 | 8 | -0.04 | 450 | 14.43 | 286 | 1857 | 6.43 / 63.57 | 6 | 61 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 62 | 14.78 | 330 | 302 | 0.30 / 51.11 | 6 | 6 |
2 | 3 | 1020.08 | 1 | 14.33 | 1085 | 16 | 0.32 / 51.13 | 6 | 24 |
3 | 7 | 2004.12 | 105 | 13.20 | 1698 | 2353 | 2.67 / 53.48 | 24 | 32 |
4 | 13 | 1480.40 | 36 | 13.80 | 1380 | 686 | 3.36 / 54.17 | 6 | 42 |
5 | 13 | 950.92 | 36 | 14.03 | 1017 | 514 | 3.87 / 54.68 | 6 | 48 |
6 | 13 | 414.60 | 36 | 14.42 | 607 | 315 | 4.19 / 55.00 | 6 | 39 |
7 | 13 | 43.76 | 36 | 14.76 | 318 | 169 | 4.35 / 55.17 | 6 | 30 |
8 | 13 | 23.44 | 36 | 14.67 | 302 | 159 | 4.51 / 55.33 | 6 | 30 |
9 | 8 | -0.04 | 450 | 14.43 | 280 | 1818 | 6.33 / 57.14 | 6 | 60 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 62 | 14.77 | 333 | 305 | 0.30 / 44.73 | 6 | 6 |
2 | 7 | 2006.36 | 105 | 13.30 | 1699 | 2373 | 2.68 / 47.10 | 6 | 33 |
3 | 13 | 1588.68 | 36 | 13.78 | 1445 | 717 | 3.39 / 47.82 | 6 | 42 |
4 | 13 | 953.76 | 36 | 14.04 | 1026 | 519 | 3.91 / 48.33 | 6 | 49 |
5 | 13 | 319.64 | 36 | 14.52 | 538 | 281 | 4.19 / 48.62 | 6 | 36 |
6 | 13 | 49.64 | 36 | 14.77 | 328 | 174 | 4.37 / 48.79 | 6 | 31 |
7 | 13 | 26.76 | 36 | 14.69 | 310 | 164 | 4.53 / 48.95 | 6 | 30 |
8 | 8 | 0.04 | 450 | 14.44 | 286 | 1858 | 6.39 / 50.81 | 6 | 61 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 62 | 14.81 | 305 | 280 | 0.28 / 38.63 | 6 | 6 |
2 | 7 | 2009.12 | 105 | 13.33 | 1661 | 2325 | 2.60 / 40.95 | 6 | 34 |
3 | 13 | 1577.28 | 36 | 13.80 | 1408 | 699 | 3.30 / 41.65 | 6 | 43 |
4 | 13 | 926.72 | 36 | 14.07 | 964 | 488 | 3.79 / 42.14 | 6 | 50 |
5 | 13 | 392.32 | 36 | 14.47 | 549 | 286 | 4.08 / 42.43 | 6 | 41 |
6 | 13 | 41.28 | 36 | 14.81 | 274 | 146 | 4.22 / 42.57 | 6 | 32 |
7 | 13 | 23.52 | 36 | 14.74 | 257 | 136 | 4.36 / 42.71 | 6 | 31 |
8 | 8 | -0.04 | 450 | 14.47 | 263 | 1713 | 6.07 / 44.42 | 6 | 63 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 61 | 14.84 | 296 | 268 | 0.27 / 32.71 | 6 | 6 |
2 | 3 | 1010.92 | 1 | 14.64 | 1031 | 15 | 0.28 / 32.73 | 6 | 14 |
3 | 7 | 2003.16 | 105 | 13.34 | 1648 | 2308 | 2.59 / 35.03 | 14 | 34 |
4 | 13 | 1476.08 | 36 | 13.84 | 1325 | 660 | 3.25 / 35.69 | 6 | 43 |
5 | 13 | 1041.16 | 36 | 14.02 | 1036 | 523 | 3.77 / 36.22 | 6 | 48 |
6 | 13 | 387.00 | 36 | 14.48 | 550 | 287 | 4.06 / 36.50 | 6 | 39 |
7 | 13 | 34.64 | 36 | 14.81 | 280 | 149 | 4.21 / 36.65 | 6 | 32 |
8 | 13 | 18.24 | 36 | 14.72 | 254 | 135 | 4.35 / 36.79 | 6 | 32 |
9 | 8 | 0.00 | 450 | 14.50 | 239 | 1559 | 5.90 / 38.35 | 6 | 64 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 61 | 14.84 | 293 | 265 | 0.27 / 27.00 | 6 | 7 |
2 | 3 | 1009.68 | 1 | 14.66 | 1005 | 15 | 0.28 / 27.02 | 6 | 14 |
3 | 7 | 2002.36 | 105 | 13.34 | 1642 | 2300 | 2.58 / 29.32 | 14 | 34 |
4 | 13 | 1486.00 | 36 | 13.82 | 1324 | 659 | 3.24 / 29.98 | 6 | 44 |
5 | 13 | 849.64 | 36 | 14.12 | 892 | 453 | 3.69 / 30.43 | 6 | 48 |
6 | 13 | 317.72 | 36 | 14.56 | 477 | 250 | 3.94 / 30.68 | 6 | 35 |
7 | 13 | 43.20 | 36 | 14.82 | 271 | 145 | 4.09 / 30.83 | 6 | 30 |
8 | 13 | 7.16 | 36 | 14.79 | 240 | 128 | 4.21 / 30.95 | 6 | 29 |
9 | 8 | -0.04 | 450 | 14.51 | 228 | 1489 | 5.70 / 32.44 | 6 | 61 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 38 | 14.97 | 288 | 164 | 0.16 / 21.00 | 6 | 6 |
2 | 10 | 1028.96 | 9 | 14.77 | 989 | 131 | 0.30 / 21.13 | 6 | 13 |
3 | 10 | 1071.16 | 8 | 14.69 | 1019 | 120 | 0.42 / 21.25 | 6 | 16 |
4 | 3 | 1108.96 | 5 | 14.75 | 1071 | 79 | 0.49 / 21.33 | 6 | 33 |
5 | 7 | 2002.28 | 105 | 13.35 | 1638 | 2296 | 2.79 / 23.63 | 33 | 34 |
6 | 13 | 1567.28 | 36 | 13.80 | 1375 | 683 | 3.47 / 24.31 | 6 | 42 |
7 | 13 | 923.00 | 36 | 14.08 | 940 | 476 | 3.95 / 24.79 | 6 | 47 |
8 | 13 | 274.72 | 36 | 14.61 | 442 | 232 | 4.18 / 25.02 | 6 | 35 |
9 | 13 | 35.60 | 36 | 14.84 | 261 | 139 | 4.32 / 25.16 | 6 | 29 |
10 | 13 | 18.40 | 36 | 14.74 | 245 | 130 | 4.45 / 25.29 | 6 | 30 |
11 | 8 | -0.04 | 450 | 14.53 | 222 | 1452 | 5.90 / 26.74 | 6 | 62 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 61 | 14.83 | 293 | 265 | 0.27 / 16.18 | 6 | 6 |
2 | 7 | 1513.68 | 105 | 13.65 | 1317 | 1888 | 2.15 / 18.06 | 6 | 33 |
3 | 13 | 1310.44 | 36 | 13.96 | 1195 | 601 | 2.75 / 18.67 | 6 | 38 |
4 | 13 | 784.64 | 36 | 14.19 | 828 | 423 | 3.18 / 19.09 | 6 | 44 |
5 | 13 | 137.20 | 36 | 14.78 | 329 | 175 | 3.35 / 19.26 | 6 | 27 |
6 | 13 | 30.68 | 36 | 14.86 | 248 | 133 | 3.48 / 19.40 | 6 | 28 |
7 | 8 | 0.12 | 450 | 14.55 | 220 | 1440 | 4.92 / 20.84 | 6 | 53 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 60 | 14.83 | 281 | 250 | 0.25 / 11.20 | 6 | 7 |
2 | 7 | 1504.60 | 106 | 13.63 | 1299 | 1877 | 2.13 / 13.08 | 6 | 33 |
3 | 13 | 1310.80 | 36 | 13.94 | 1189 | 597 | 2.72 / 13.67 | 6 | 38 |
4 | 13 | 983.72 | 36 | 14.06 | 974 | 493 | 3.22 / 14.17 | 6 | 44 |
5 | 13 | 116.16 | 36 | 14.79 | 314 | 167 | 3.38 / 14.33 | 6 | 26 |
6 | 13 | 29.80 | 36 | 14.85 | 250 | 134 | 3.52 / 14.47 | 6 | 25 |
7 | 8 | 0.04 | 450 | 14.54 | 221 | 1446 | 4.96 / 15.91 | 6 | 58 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 38 | 14.89 | 278 | 157 | 0.16 / 5.93 | 6 | 6 |
2 | 10 | 1046.84 | 11 | 14.67 | 997 | 161 | 0.32 / 6.09 | 6 | 14 |
3 | 10 | 1078.48 | 6 | 14.62 | 1022 | 90 | 0.41 / 6.18 | 6 | 15 |
4 | 3 | 1113.56 | 6 | 14.67 | 1083 | 95 | 0.50 / 6.27 | 6 | 33 |
5 | 7 | 1514.80 | 105 | 13.57 | 1315 | 1874 | 2.38 / 8.14 | 33 | 33 |
6 | 13 | 1314.68 | 36 | 13.89 | 1206 | 603 | 2.98 / 8.75 | 6 | 40 |
7 | 13 | 879.52 | 36 | 14.07 | 902 | 457 | 3.44 / 9.20 | 6 | 43 |
8 | 13 | 127.84 | 36 | 14.76 | 323 | 172 | 3.61 / 9.38 | 6 | 28 |
9 | 13 | 34.80 | 36 | 14.83 | 251 | 134 | 3.74 / 9.51 | 6 | 25 |
10 | 8 | 0.12 | 450 | 14.53 | 220 | 1438 | 5.18 / 10.95 | 6 | 57 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 38 | 14.88 | 268 | 152 | 0.15 / 2.28 | 6 | 6 |
2 | 10 | 1037.20 | 11 | 14.50 | 974 | 155 | 0.31 / 2.44 | 6 | 12 |
3 | 10 | 1067.40 | 6 | 14.49 | 1009 | 88 | 0.39 / 2.52 | 6 | 14 |
4 | 3 | 1101.84 | 5 | 14.52 | 1047 | 76 | 0.47 / 2.60 | 6 | 21 |
5 | 7 | 1041.48 | 105 | 13.73 | 991 | 1429 | 1.90 / 4.03 | 21 | 34 |
6 | 13 | 247.48 | 36 | 14.57 | 410 | 215 | 2.11 / 4.24 | 6 | 28 |
7 | 13 | 33.88 | 36 | 14.78 | 249 | 132 | 2.25 / 4.38 | 6 | 28 |
8 | 8 | 0.08 | 450 | 14.52 | 213 | 1392 | 3.64 / 5.77 | 6 | 51 |
Average= | 2.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 59.24 | 38 | 14.64 | 244 | 136 | 0.14 / 0.14 | 6 | 7 |
2 | 7 | 68.12 | 105 | 14.53 | 247 | 377 | 0.51 / 0.51 | 7 | 9 |
3 | 13 | 59.36 | 36 | 14.75 | 244 | 130 | 0.64 / 0.64 | 6 | 9 |
4 | 13 | 35.56 | 36 | 14.79 | 221 | 118 | 0.76 / 0.76 | 6 | 11 |
5 | 13 | 17.96 | 36 | 14.78 | 209 | 111 | 0.87 / 0.87 | 6 | 13 |
6 | 8 | 0.24 | 450 | 14.64 | 191 | 1258 | 2.13 / 2.13 | 6 | 46 |
Average= | 2.13 (KJ/cycle) |