SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 102 | 10.27 | 325 | 340 | 0.34 / 1723.73 | 6 | 8 |
2 | 3 | 1012.12 | 1 | 7.52 | 942 | 7 | 0.35 / 1723.74 | 5 | 5 |
3 | 7 | 1021.76 | 106 | 6.87 | 952 | 693 | 1.04 / 1724.43 | 5 | 13 |
4 | 13 | 925.60 | 36 | 7.28 | 903 | 237 | 1.28 / 1724.67 | 5 | 16 |
5 | 13 | 828.56 | 36 | 7.60 | 840 | 230 | 1.51 / 1724.90 | 5 | 18 |
6 | 13 | 325.52 | 36 | 9.26 | 492 | 164 | 1.67 / 1725.07 | 5 | 23 |
7 | 13 | 48.20 | 36 | 10.17 | 286 | 105 | 1.78 / 1725.17 | 6 | 22 |
8 | 13 | 25.48 | 36 | 10.25 | 269 | 99 | 1.88 / 1725.27 | 6 | 23 |
9 | 8 | 0.04 | 450 | 10.40 | 248 | 1161 | 3.04 / 1726.43 | 6 | 39 |
Average= | 5.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 101 | 10.29 | 323 | 336 | 0.34 / 1720.58 | 6 | 8 |
2 | 3 | 1014.12 | 1 | 7.75 | 944 | 7 | 0.34 / 1720.58 | 5 | 5 |
3 | 7 | 1018.72 | 105 | 7.07 | 950 | 705 | 1.05 / 1721.29 | 5 | 14 |
4 | 13 | 928.72 | 36 | 7.43 | 905 | 242 | 1.29 / 1721.53 | 5 | 17 |
5 | 13 | 840.80 | 36 | 7.71 | 851 | 236 | 1.53 / 1721.77 | 5 | 18 |
6 | 13 | 536.72 | 36 | 8.67 | 638 | 199 | 1.73 / 1721.97 | 5 | 23 |
7 | 13 | 314.68 | 36 | 9.38 | 482 | 163 | 1.89 / 1722.13 | 5 | 24 |
8 | 13 | 23.72 | 36 | 10.30 | 265 | 98 | 1.99 / 1722.23 | 6 | 23 |
9 | 8 | 0.08 | 450 | 10.42 | 249 | 1168 | 3.15 / 1723.39 | 6 | 37 |
Average= | 5.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 101 | 10.35 | 325 | 340 | 0.34 / 1717.45 | 6 | 9 |
2 | 3 | 1019.72 | 1 | 7.86 | 955 | 8 | 0.35 / 1717.45 | 5 | 5 |
3 | 7 | 1021.84 | 105 | 7.25 | 953 | 725 | 1.07 / 1718.18 | 5 | 15 |
4 | 13 | 942.92 | 36 | 7.51 | 920 | 249 | 1.32 / 1718.43 | 5 | 17 |
5 | 13 | 740.48 | 36 | 8.13 | 783 | 229 | 1.55 / 1718.66 | 5 | 21 |
6 | 13 | 531.44 | 36 | 8.77 | 639 | 202 | 1.75 / 1718.86 | 5 | 24 |
7 | 13 | 56.92 | 36 | 10.21 | 293 | 108 | 1.86 / 1718.97 | 6 | 23 |
8 | 13 | 31.20 | 36 | 10.30 | 277 | 103 | 1.96 / 1719.07 | 6 | 24 |
9 | 8 | 0.12 | 450 | 10.45 | 249 | 1171 | 3.13 / 1720.24 | 6 | 42 |
Average= | 5.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 101 | 10.27 | 328 | 340 | 0.34 / 1711.22 | 6 | 8 |
2 | 3 | 1018.12 | 1 | 7.69 | 943 | 7 | 0.35 / 1711.23 | 5 | 5 |
3 | 7 | 2004.16 | 105 | 4.55 | 1576 | 753 | 1.10 / 1711.98 | 5 | 6 |
4 | 13 | 2062.36 | 36 | 4.64 | 1604 | 268 | 1.37 / 1712.25 | 5 | 6 |
5 | 13 | 2084.56 | 36 | 4.70 | 1624 | 275 | 1.64 / 1712.52 | 5 | 6 |
6 | 13 | 2065.96 | 36 | 4.61 | 1634 | 271 | 1.91 / 1712.80 | 5 | 6 |
7 | 13 | 2031.68 | 36 | 4.66 | 1611 | 270 | 2.18 / 1713.07 | 5 | 6 |
8 | 13 | 1987.88 | 36 | 4.71 | 1582 | 268 | 2.45 / 1713.33 | 5 | 6 |
9 | 13 | 1934.28 | 36 | 4.90 | 1547 | 273 | 2.73 / 1713.61 | 5 | 6 |
10 | 13 | 1871.52 | 36 | 4.98 | 1515 | 272 | 3.00 / 1713.88 | 5 | 6 |
11 | 13 | 1806.60 | 36 | 5.13 | 1469 | 271 | 3.27 / 1714.15 | 5 | 6 |
12 | 13 | 1730.16 | 36 | 5.42 | 1415 | 276 | 3.54 / 1714.43 | 5 | 7 |
13 | 13 | 1649.16 | 36 | 5.66 | 1365 | 278 | 3.82 / 1714.70 | 5 | 8 |
14 | 13 | 1566.96 | 36 | 5.77 | 1313 | 273 | 4.10 / 1714.98 | 5 | 10 |
15 | 13 | 1383.84 | 36 | 6.32 | 1204 | 274 | 4.37 / 1715.25 | 5 | 12 |
16 | 13 | 1296.40 | 36 | 6.61 | 1146 | 273 | 4.64 / 1715.52 | 5 | 14 |
17 | 13 | 1001.20 | 36 | 7.31 | 967 | 254 | 4.90 / 1715.78 | 5 | 19 |
18 | 13 | 908.80 | 36 | 7.61 | 902 | 247 | 5.14 / 1716.03 | 5 | 21 |
19 | 13 | 482.40 | 36 | 8.91 | 605 | 194 | 5.34 / 1716.22 | 5 | 25 |
20 | 13 | 384.56 | 36 | 9.25 | 539 | 179 | 5.52 / 1716.40 | 5 | 26 |
21 | 13 | 73.52 | 36 | 10.17 | 306 | 112 | 5.63 / 1716.51 | 6 | 25 |
22 | 8 | 0.04 | 147 | 10.46 | 253 | 389 | 6.02 / 1716.90 | 6 | 29 |
23 | 14 | -0.04 | 78 | 10.45 | 253 | 206 | 6.22 / 1717.11 | 6 | 40 |
Average= | 5.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 101 | 10.30 | 327 | 340 | 0.34 / 1708.12 | 6 | 8 |
2 | 7 | 1029.12 | 105 | 7.15 | 961 | 721 | 1.06 / 1708.85 | 5 | 14 |
3 | 13 | 847.52 | 36 | 7.78 | 856 | 240 | 1.30 / 1709.09 | 5 | 18 |
4 | 13 | 667.68 | 36 | 8.35 | 732 | 220 | 1.52 / 1709.31 | 5 | 21 |
5 | 13 | 474.56 | 36 | 8.95 | 598 | 193 | 1.71 / 1709.50 | 5 | 23 |
6 | 13 | 79.56 | 36 | 10.15 | 310 | 113 | 1.83 / 1709.61 | 6 | 23 |
7 | 13 | 40.16 | 36 | 10.26 | 281 | 104 | 1.93 / 1709.72 | 6 | 23 |
8 | 8 | 0.12 | 450 | 10.45 | 248 | 1166 | 3.10 / 1710.88 | 6 | 35 |
Average= | 5.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 101 | 10.38 | 319 | 334 | 0.33 / 1704.94 | 6 | 8 |
2 | 7 | 1016.72 | 105 | 7.35 | 953 | 735 | 1.07 / 1705.68 | 8 | 15 |
3 | 13 | 922.84 | 36 | 7.72 | 907 | 252 | 1.32 / 1705.93 | 5 | 17 |
4 | 13 | 832.80 | 36 | 7.96 | 845 | 242 | 1.56 / 1706.17 | 5 | 20 |
5 | 13 | 620.44 | 36 | 8.62 | 704 | 218 | 1.78 / 1706.39 | 5 | 23 |
6 | 13 | 85.08 | 36 | 10.18 | 316 | 116 | 1.90 / 1706.50 | 6 | 23 |
7 | 13 | 42.72 | 36 | 10.30 | 285 | 106 | 2.00 / 1706.61 | 6 | 24 |
8 | 8 | 0.04 | 450 | 10.48 | 249 | 1174 | 3.18 / 1707.78 | 6 | 43 |
Average= | 5.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 100 | 10.41 | 323 | 336 | 0.34 / 1701.71 | 6 | 8 |
2 | 3 | 1021.28 | 1 | 8.04 | 948 | 8 | 0.34 / 1701.71 | 5 | 6 |
3 | 7 | 1019.84 | 105 | 7.47 | 963 | 755 | 1.10 / 1702.47 | 6 | 16 |
4 | 13 | 921.24 | 36 | 7.83 | 904 | 255 | 1.35 / 1702.72 | 5 | 18 |
5 | 13 | 725.72 | 36 | 8.39 | 777 | 235 | 1.59 / 1702.96 | 5 | 21 |
6 | 13 | 424.08 | 36 | 9.26 | 564 | 188 | 1.78 / 1703.15 | 5 | 25 |
7 | 13 | 29.24 | 36 | 10.38 | 269 | 101 | 1.88 / 1703.25 | 6 | 23 |
8 | 13 | 16.40 | 36 | 10.40 | 264 | 99 | 1.98 / 1703.35 | 6 | 25 |
9 | 13 | 3.28 | 36 | 10.47 | 254 | 96 | 2.07 / 1703.44 | 6 | 25 |
10 | 8 | 0.00 | 450 | 10.52 | 246 | 1165 | 3.24 / 1704.61 | 6 | 38 |
Average= | 5.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 99 | 10.32 | 330 | 337 | 0.34 / 1696.07 | 6 | 8 |
2 | 3 | 1028.68 | 1 | 8.01 | 961 | 8 | 0.34 / 1696.07 | 5 | 6 |
3 | 7 | 2002.08 | 106 | 4.90 | 1583 | 822 | 1.17 / 1696.90 | 6 | 6 |
4 | 13 | 1994.68 | 36 | 5.20 | 1594 | 298 | 1.47 / 1697.19 | 5 | 6 |
5 | 13 | 1953.36 | 36 | 5.35 | 1564 | 301 | 1.77 / 1697.50 | 5 | 5 |
6 | 13 | 1899.92 | 36 | 5.55 | 1521 | 304 | 2.07 / 1697.80 | 5 | 6 |
7 | 13 | 1846.12 | 36 | 5.60 | 1500 | 302 | 2.37 / 1698.10 | 5 | 6 |
8 | 13 | 1785.64 | 36 | 5.71 | 1459 | 300 | 2.67 / 1698.40 | 5 | 7 |
9 | 13 | 1714.32 | 36 | 5.94 | 1415 | 303 | 2.98 / 1698.70 | 5 | 8 |
10 | 13 | 1628.68 | 36 | 6.11 | 1364 | 300 | 3.28 / 1699.00 | 5 | 10 |
11 | 13 | 1534.12 | 36 | 6.31 | 1301 | 296 | 3.57 / 1699.30 | 5 | 11 |
12 | 13 | 1436.44 | 36 | 6.58 | 1237 | 293 | 3.86 / 1699.59 | 5 | 13 |
13 | 13 | 1236.84 | 36 | 7.03 | 1117 | 283 | 4.15 / 1699.88 | 5 | 17 |
14 | 13 | 935.28 | 36 | 7.78 | 924 | 259 | 4.41 / 1700.13 | 5 | 22 |
15 | 13 | 632.92 | 36 | 8.67 | 715 | 223 | 4.63 / 1700.36 | 5 | 26 |
16 | 13 | 220.92 | 36 | 9.87 | 414 | 147 | 4.78 / 1700.51 | 5 | 25 |
17 | 13 | 25.80 | 36 | 10.39 | 270 | 101 | 4.88 / 1700.61 | 6 | 24 |
18 | 8 | 0.16 | 290 | 10.53 | 250 | 763 | 5.64 / 1701.37 | 6 | 35 |
Average= | 5.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 100 | 10.44 | 325 | 339 | 0.34 / 1693.00 | 6 | 8 |
2 | 3 | 1011.32 | 1 | 8.08 | 946 | 8 | 0.35 / 1693.01 | 5 | 5 |
3 | 7 | 1018.56 | 105 | 7.45 | 963 | 753 | 1.10 / 1693.76 | 5 | 16 |
4 | 13 | 921.56 | 36 | 7.83 | 911 | 257 | 1.36 / 1694.02 | 5 | 18 |
5 | 13 | 825.44 | 36 | 8.12 | 846 | 247 | 1.60 / 1694.27 | 5 | 20 |
6 | 13 | 404.40 | 36 | 9.32 | 552 | 185 | 1.79 / 1694.45 | 5 | 25 |
7 | 13 | 51.68 | 36 | 10.34 | 287 | 107 | 1.90 / 1694.56 | 6 | 23 |
8 | 8 | 0.08 | 450 | 10.52 | 247 | 1169 | 3.07 / 1695.73 | 6 | 37 |
Average= | 5.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 100 | 10.45 | 322 | 336 | 0.34 / 1689.85 | 6 | 8 |
2 | 7 | 1022.84 | 105 | 7.60 | 962 | 768 | 1.10 / 1690.61 | 5 | 16 |
3 | 13 | 935.28 | 36 | 7.93 | 920 | 263 | 1.37 / 1690.88 | 5 | 18 |
4 | 13 | 729.44 | 36 | 8.47 | 780 | 238 | 1.60 / 1691.11 | 5 | 22 |
5 | 13 | 347.16 | 36 | 9.54 | 509 | 175 | 1.78 / 1691.29 | 5 | 24 |
6 | 13 | 33.88 | 36 | 10.40 | 275 | 103 | 1.88 / 1691.39 | 6 | 23 |
7 | 13 | 17.76 | 36 | 10.43 | 265 | 100 | 1.98 / 1691.49 | 6 | 24 |
8 | 8 | 0.00 | 450 | 10.54 | 247 | 1172 | 3.15 / 1692.66 | 6 | 47 |
Average= | 5.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 99 | 10.49 | 320 | 332 | 0.33 / 1686.74 | 6 | 9 |
2 | 3 | 1021.44 | 1 | 8.33 | 952 | 8 | 0.34 / 1686.75 | 5 | 6 |
3 | 7 | 1022.60 | 105 | 7.77 | 954 | 778 | 1.12 / 1687.52 | 6 | 17 |
4 | 13 | 923.48 | 36 | 8.07 | 912 | 265 | 1.38 / 1687.79 | 5 | 19 |
5 | 13 | 721.76 | 36 | 8.58 | 778 | 240 | 1.62 / 1688.03 | 5 | 22 |
6 | 13 | 508.60 | 36 | 9.17 | 624 | 206 | 1.83 / 1688.24 | 5 | 26 |
7 | 13 | 22.24 | 36 | 10.48 | 263 | 99 | 1.93 / 1688.34 | 6 | 24 |
8 | 8 | 0.12 | 450 | 10.57 | 247 | 1175 | 3.10 / 1689.51 | 6 | 31 |
Average= | 5.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 99 | 10.42 | 326 | 336 | 0.34 / 1681.13 | 6 | 9 |
2 | 7 | 2003.68 | 105 | 5.39 | 1587 | 898 | 1.23 / 1682.03 | 5 | 5 |
3 | 13 | 1981.64 | 36 | 5.67 | 1581 | 323 | 1.56 / 1682.35 | 5 | 5 |
4 | 13 | 1939.96 | 36 | 5.84 | 1551 | 326 | 1.88 / 1682.68 | 5 | 6 |
5 | 13 | 1881.96 | 36 | 5.88 | 1532 | 324 | 2.21 / 1683.01 | 5 | 7 |
6 | 13 | 1812.68 | 36 | 6.12 | 1477 | 325 | 2.53 / 1683.33 | 5 | 8 |
7 | 13 | 1734.88 | 36 | 6.23 | 1430 | 321 | 2.85 / 1683.65 | 5 | 10 |
8 | 13 | 1652.12 | 36 | 6.44 | 1383 | 321 | 3.17 / 1683.97 | 5 | 11 |
9 | 13 | 1564.88 | 36 | 6.68 | 1324 | 318 | 3.49 / 1684.29 | 5 | 13 |
10 | 13 | 1367.44 | 36 | 7.05 | 1206 | 306 | 3.80 / 1684.60 | 5 | 16 |
11 | 13 | 1078.32 | 36 | 7.71 | 1024 | 284 | 4.08 / 1684.88 | 5 | 21 |
12 | 13 | 873.64 | 36 | 8.21 | 888 | 262 | 4.35 / 1685.14 | 5 | 24 |
13 | 13 | 451.44 | 36 | 9.35 | 588 | 198 | 4.54 / 1685.34 | 5 | 27 |
14 | 13 | 61.80 | 36 | 10.38 | 299 | 112 | 4.66 / 1685.45 | 6 | 25 |
15 | 8 | 0.08 | 363 | 10.59 | 248 | 953 | 5.61 / 1686.41 | 6 | 39 |
Average= | 5.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 99 | 10.48 | 327 | 339 | 0.34 / 1678.20 | 6 | 9 |
2 | 3 | 1010.52 | 1 | 8.43 | 958 | 8 | 0.35 / 1678.21 | 5 | 5 |
3 | 7 | 1018.88 | 105 | 7.73 | 962 | 781 | 1.13 / 1678.99 | 5 | 17 |
4 | 13 | 926.08 | 36 | 8.07 | 916 | 266 | 1.39 / 1679.26 | 5 | 20 |
5 | 13 | 726.96 | 36 | 8.56 | 782 | 241 | 1.64 / 1679.50 | 5 | 23 |
6 | 13 | 124.48 | 36 | 10.21 | 341 | 125 | 1.76 / 1679.62 | 6 | 24 |
7 | 8 | 0.16 | 450 | 10.57 | 247 | 1175 | 2.94 / 1680.80 | 6 | 39 |
Average= | 5.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 99 | 10.51 | 324 | 337 | 0.34 / 1675.10 | 6 | 9 |
2 | 3 | 1010.32 | 1 | 8.33 | 965 | 8 | 0.35 / 1675.11 | 5 | 5 |
3 | 7 | 1016.12 | 105 | 7.86 | 958 | 791 | 1.14 / 1675.90 | 5 | 17 |
4 | 13 | 926.76 | 36 | 8.17 | 914 | 269 | 1.40 / 1676.17 | 5 | 20 |
5 | 13 | 615.28 | 36 | 8.95 | 706 | 227 | 1.63 / 1676.40 | 5 | 24 |
6 | 13 | 310.60 | 36 | 9.74 | 483 | 169 | 1.80 / 1676.57 | 5 | 26 |
7 | 13 | 45.04 | 36 | 10.43 | 284 | 107 | 1.91 / 1676.67 | 6 | 25 |
8 | 8 | 0.16 | 450 | 10.57 | 250 | 1189 | 3.10 / 1677.86 | 6 | 38 |
Average= | 5.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 99 | 10.51 | 325 | 338 | 0.34 / 1672.15 | 6 | 9 |
2 | 7 | 1017.80 | 105 | 7.97 | 964 | 807 | 1.14 / 1672.96 | 5 | 19 |
3 | 13 | 923.64 | 36 | 8.29 | 916 | 273 | 1.42 / 1673.23 | 5 | 21 |
4 | 13 | 619.36 | 36 | 8.99 | 709 | 229 | 1.65 / 1673.46 | 5 | 25 |
5 | 13 | 116.04 | 36 | 10.31 | 336 | 125 | 1.77 / 1673.58 | 6 | 24 |
6 | 8 | 0.12 | 450 | 10.62 | 247 | 1180 | 2.95 / 1674.77 | 6 | 32 |
Average= | 5.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 99 | 10.55 | 326 | 340 | 0.34 / 1666.50 | 6 | 9 |
2 | 3 | 1009.88 | 1 | 8.36 | 971 | 8 | 0.35 / 1666.51 | 5 | 5 |
3 | 7 | 2009.64 | 105 | 5.78 | 1589 | 964 | 1.31 / 1667.47 | 5 | 5 |
4 | 13 | 1969.96 | 36 | 6.07 | 1581 | 345 | 1.66 / 1667.82 | 5 | 6 |
5 | 13 | 1903.96 | 36 | 6.23 | 1541 | 346 | 2.00 / 1668.16 | 5 | 7 |
6 | 13 | 1832.48 | 36 | 6.39 | 1505 | 346 | 2.35 / 1668.51 | 5 | 8 |
7 | 13 | 1766.60 | 36 | 6.62 | 1449 | 345 | 2.70 / 1668.85 | 5 | 10 |
8 | 13 | 1685.04 | 36 | 6.70 | 1407 | 339 | 3.03 / 1669.19 | 5 | 12 |
9 | 13 | 1588.52 | 36 | 6.85 | 1355 | 334 | 3.37 / 1669.53 | 5 | 13 |
10 | 13 | 1294.16 | 36 | 7.53 | 1167 | 316 | 3.69 / 1669.84 | 5 | 18 |
11 | 13 | 1198.56 | 36 | 7.69 | 1106 | 306 | 3.99 / 1670.15 | 5 | 21 |
12 | 13 | 984.28 | 36 | 8.12 | 967 | 283 | 4.27 / 1670.43 | 5 | 24 |
13 | 13 | 468.52 | 36 | 9.41 | 605 | 205 | 4.48 / 1670.64 | 5 | 28 |
14 | 13 | 85.60 | 36 | 10.41 | 313 | 117 | 4.60 / 1670.76 | 6 | 25 |
15 | 8 | 0.24 | 399 | 10.64 | 249 | 1057 | 5.65 / 1671.81 | 6 | 36 |
Average= | 5.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 98 | 10.49 | 333 | 342 | 0.34 / 1663.48 | 6 | 9 |
2 | 3 | 1010.40 | 1 | 8.57 | 963 | 8 | 0.35 / 1663.49 | 5 | 5 |
3 | 7 | 1023.00 | 106 | 7.95 | 966 | 814 | 1.16 / 1664.31 | 5 | 18 |
4 | 13 | 828.68 | 36 | 8.55 | 849 | 261 | 1.43 / 1664.57 | 5 | 22 |
5 | 13 | 738.64 | 36 | 8.75 | 788 | 248 | 1.67 / 1664.82 | 5 | 24 |
6 | 13 | 312.76 | 36 | 9.83 | 484 | 171 | 1.85 / 1664.99 | 5 | 26 |
7 | 8 | 0.00 | 450 | 10.63 | 245 | 1172 | 3.02 / 1666.16 | 6 | 35 |
Average= | 5.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 96 | 10.55 | 325 | 329 | 0.33 / 1660.39 | 6 | 9 |
2 | 3 | 1051.32 | 3 | 8.28 | 999 | 25 | 0.35 / 1660.42 | 5 | 10 |
3 | 7 | 1047.04 | 105 | 7.94 | 988 | 824 | 1.18 / 1661.24 | 10 | 19 |
4 | 13 | 948.84 | 36 | 8.30 | 934 | 279 | 1.46 / 1661.52 | 5 | 21 |
5 | 13 | 641.32 | 36 | 9.01 | 726 | 235 | 1.69 / 1661.76 | 5 | 25 |
6 | 13 | 436.80 | 36 | 9.54 | 576 | 198 | 1.89 / 1661.95 | 5 | 26 |
7 | 8 | 0.24 | 450 | 10.64 | 248 | 1187 | 3.08 / 1663.14 | 6 | 27 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 99 | 10.59 | 320 | 335 | 0.34 / 1657.41 | 6 | 9 |
2 | 7 | 985.36 | 105 | 8.19 | 951 | 818 | 1.15 / 1658.23 | 9 | 20 |
3 | 13 | 891.36 | 36 | 8.52 | 899 | 276 | 1.43 / 1658.51 | 5 | 21 |
4 | 13 | 491.16 | 36 | 9.42 | 626 | 212 | 1.64 / 1658.72 | 5 | 26 |
5 | 13 | 181.44 | 36 | 10.18 | 393 | 144 | 1.79 / 1658.86 | 5 | 26 |
6 | 8 | 0.68 | 450 | 10.64 | 251 | 1202 | 2.99 / 1660.06 | 6 | 43 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 98 | 10.53 | 325 | 335 | 0.34 / 1651.69 | 6 | 9 |
2 | 7 | 2010.36 | 105 | 6.06 | 1608 | 1023 | 1.36 / 1652.71 | 5 | 5 |
3 | 13 | 1964.92 | 36 | 6.35 | 1593 | 364 | 1.72 / 1653.07 | 5 | 7 |
4 | 13 | 1902.36 | 36 | 6.52 | 1548 | 363 | 2.09 / 1653.44 | 5 | 8 |
5 | 13 | 1839.96 | 36 | 6.66 | 1507 | 361 | 2.45 / 1653.80 | 5 | 10 |
6 | 13 | 1772.88 | 36 | 6.81 | 1470 | 360 | 2.81 / 1654.16 | 5 | 11 |
7 | 13 | 1680.16 | 36 | 7.02 | 1406 | 355 | 3.16 / 1654.51 | 5 | 14 |
8 | 13 | 1469.84 | 36 | 7.40 | 1280 | 341 | 3.50 / 1654.85 | 5 | 17 |
9 | 13 | 1269.56 | 36 | 7.75 | 1156 | 323 | 3.83 / 1655.18 | 5 | 21 |
10 | 13 | 1068.72 | 36 | 8.21 | 1026 | 303 | 4.13 / 1655.48 | 5 | 24 |
11 | 13 | 753.12 | 36 | 8.88 | 809 | 259 | 4.39 / 1655.74 | 5 | 28 |
12 | 13 | 339.40 | 36 | 9.84 | 510 | 181 | 4.57 / 1655.92 | 5 | 28 |
13 | 8 | 0.00 | 435 | 10.68 | 249 | 1157 | 5.73 / 1657.08 | 6 | 33 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 99 | 10.54 | 328 | 342 | 0.34 / 1648.39 | 6 | 9 |
2 | 3 | 967.80 | -1 | 10.54 | 328 | 0 | 0.00 / 1648.39 | 6 | 9 |
3 | 7 | 1056.24 | 105 | 7.98 | 1002 | 840 | 1.18 / 1649.23 | 9 | 19 |
4 | 13 | 861.32 | 36 | 8.55 | 881 | 271 | 1.45 / 1649.50 | 5 | 23 |
5 | 13 | 768.24 | 36 | 8.81 | 818 | 259 | 1.71 / 1649.76 | 5 | 26 |
6 | 13 | 345.32 | 36 | 9.80 | 512 | 181 | 1.89 / 1649.94 | 5 | 27 |
7 | 13 | 59.56 | 36 | 10.50 | 296 | 112 | 2.00 / 1650.05 | 6 | 25 |
8 | 13 | 35.76 | 36 | 10.54 | 278 | 105 | 2.11 / 1650.16 | 6 | 26 |
9 | 8 | 0.12 | 450 | 10.65 | 249 | 1193 | 3.30 / 1651.35 | 6 | 52 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 99 | 10.50 | 332 | 345 | 0.35 / 1645.23 | 6 | 9 |
2 | 7 | 1006.96 | 105 | 8.17 | 966 | 829 | 1.17 / 1646.06 | 9 | 19 |
3 | 13 | 824.16 | 36 | 8.67 | 857 | 267 | 1.44 / 1646.33 | 5 | 24 |
4 | 13 | 608.40 | 36 | 9.21 | 707 | 234 | 1.68 / 1646.56 | 5 | 26 |
5 | 13 | 387.68 | 36 | 9.69 | 546 | 190 | 1.87 / 1646.75 | 5 | 28 |
6 | 13 | 14.88 | 36 | 10.61 | 261 | 100 | 1.97 / 1646.85 | 6 | 26 |
7 | 8 | 0.04 | 450 | 10.65 | 249 | 1193 | 3.16 / 1648.05 | 6 | 46 |
Average= | 5.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 99 | 10.58 | 330 | 346 | 0.35 / 1642.07 | 6 | 9 |
2 | 7 | 1005.88 | 105 | 8.29 | 963 | 838 | 1.18 / 1642.91 | 9 | 19 |
3 | 13 | 910.80 | 36 | 8.58 | 914 | 282 | 1.47 / 1643.19 | 5 | 22 |
4 | 13 | 695.60 | 36 | 9.05 | 766 | 250 | 1.72 / 1643.44 | 5 | 26 |
5 | 13 | 146.24 | 36 | 10.33 | 364 | 135 | 1.85 / 1643.58 | 6 | 26 |
6 | 13 | 13.36 | 36 | 10.62 | 264 | 101 | 1.95 / 1643.68 | 6 | 26 |
7 | 8 | 0.04 | 450 | 10.67 | 252 | 1210 | 3.16 / 1644.89 | 6 | 39 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 98 | 10.58 | 325 | 337 | 0.34 / 1636.34 | 6 | 9 |
2 | 7 | 2014.48 | 106 | 6.26 | 1614 | 1071 | 1.41 / 1637.41 | 9 | 6 |
3 | 13 | 1972.04 | 36 | 6.56 | 1598 | 377 | 1.79 / 1637.79 | 5 | 7 |
4 | 13 | 1909.56 | 36 | 6.70 | 1555 | 375 | 2.16 / 1638.16 | 5 | 9 |
5 | 13 | 1828.32 | 36 | 6.87 | 1507 | 373 | 2.53 / 1638.53 | 5 | 11 |
6 | 13 | 1744.32 | 36 | 7.03 | 1459 | 369 | 2.90 / 1638.90 | 5 | 13 |
7 | 13 | 1658.04 | 36 | 7.25 | 1396 | 364 | 3.27 / 1639.27 | 5 | 16 |
8 | 13 | 1460.32 | 36 | 7.57 | 1279 | 349 | 3.62 / 1639.62 | 5 | 19 |
9 | 13 | 1056.48 | 36 | 8.32 | 1023 | 306 | 3.92 / 1639.92 | 5 | 25 |
10 | 13 | 854.44 | 36 | 8.72 | 886 | 278 | 4.20 / 1640.20 | 5 | 28 |
11 | 13 | 416.76 | 36 | 9.75 | 569 | 200 | 4.40 / 1640.40 | 5 | 29 |
12 | 13 | 207.48 | 36 | 10.22 | 414 | 152 | 4.55 / 1640.55 | 5 | 28 |
13 | 8 | 0.16 | 434 | 10.69 | 253 | 1174 | 5.73 / 1641.73 | 6 | 43 |
Average= | 5.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 99 | 10.54 | 331 | 345 | 0.35 / 1633.13 | 6 | 9 |
2 | 7 | 1001.64 | 105 | 8.20 | 966 | 832 | 1.18 / 1633.96 | 9 | 20 |
3 | 13 | 899.16 | 36 | 8.54 | 907 | 279 | 1.46 / 1634.24 | 5 | 22 |
4 | 13 | 802.64 | 36 | 8.80 | 841 | 266 | 1.72 / 1634.51 | 5 | 25 |
5 | 13 | 375.80 | 36 | 9.77 | 536 | 189 | 1.91 / 1634.69 | 5 | 28 |
6 | 13 | 34.36 | 36 | 10.57 | 277 | 105 | 2.02 / 1634.80 | 6 | 25 |
7 | 8 | 0.08 | 450 | 10.67 | 250 | 1200 | 3.22 / 1636.00 | 6 | 35 |
Average= | 5.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 99 | 10.60 | 313 | 328 | 0.33 / 1629.98 | 6 | 8 |
2 | 7 | 1001.96 | 105 | 8.27 | 965 | 838 | 1.17 / 1630.82 | 8 | 19 |
3 | 13 | 902.12 | 36 | 8.64 | 907 | 282 | 1.45 / 1631.10 | 5 | 22 |
4 | 13 | 597.28 | 36 | 9.30 | 699 | 234 | 1.68 / 1631.33 | 5 | 26 |
5 | 13 | 174.76 | 36 | 10.30 | 385 | 143 | 1.83 / 1631.47 | 5 | 26 |
6 | 13 | 39.96 | 36 | 10.56 | 282 | 107 | 1.93 / 1631.58 | 6 | 25 |
7 | 8 | 0.00 | 450 | 10.68 | 250 | 1201 | 3.13 / 1632.78 | 7 | 39 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 98 | 10.65 | 310 | 324 | 0.32 / 1626.96 | 6 | 8 |
2 | 3 | 1020.16 | 1 | 8.94 | 949 | 8 | 0.33 / 1626.97 | 5 | 6 |
3 | 7 | 1010.72 | 105 | 8.37 | 962 | 845 | 1.18 / 1627.81 | 6 | 20 |
4 | 13 | 810.16 | 36 | 8.83 | 847 | 269 | 1.45 / 1628.08 | 5 | 24 |
5 | 13 | 511.64 | 36 | 9.54 | 635 | 218 | 1.66 / 1628.30 | 5 | 26 |
6 | 13 | 203.96 | 36 | 10.22 | 404 | 149 | 1.81 / 1628.45 | 5 | 26 |
7 | 8 | 0.08 | 450 | 10.70 | 249 | 1199 | 3.01 / 1629.65 | 6 | 32 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 98 | 10.58 | 333 | 345 | 0.35 / 1621.23 | 6 | 8 |
2 | 7 | 2005.24 | 105 | 6.39 | 1597 | 1072 | 1.42 / 1622.30 | 5 | 6 |
3 | 13 | 1976.36 | 36 | 6.62 | 1599 | 381 | 1.80 / 1622.68 | 5 | 7 |
4 | 13 | 1927.96 | 36 | 6.73 | 1577 | 382 | 2.18 / 1623.06 | 5 | 9 |
5 | 13 | 1847.96 | 36 | 6.91 | 1523 | 379 | 2.56 / 1623.44 | 5 | 11 |
6 | 13 | 1754.16 | 36 | 7.05 | 1465 | 372 | 2.93 / 1623.81 | 5 | 13 |
7 | 13 | 1655.28 | 36 | 7.35 | 1392 | 368 | 3.30 / 1624.18 | 5 | 15 |
8 | 13 | 1455.92 | 36 | 7.64 | 1278 | 352 | 3.65 / 1624.53 | 5 | 19 |
9 | 13 | 1164.08 | 36 | 8.22 | 1088 | 322 | 3.97 / 1624.86 | 5 | 23 |
10 | 13 | 853.36 | 36 | 8.81 | 879 | 279 | 4.25 / 1625.13 | 5 | 28 |
11 | 13 | 543.20 | 36 | 9.49 | 660 | 225 | 4.48 / 1625.36 | 5 | 30 |
12 | 13 | 117.80 | 36 | 10.46 | 341 | 128 | 4.61 / 1625.49 | 6 | 26 |
13 | 8 | 0.08 | 435 | 10.73 | 246 | 1148 | 5.75 / 1626.64 | 6 | 44 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 99 | 10.64 | 322 | 339 | 0.34 / 1618.13 | 6 | 8 |
2 | 7 | 1004.60 | 105 | 8.30 | 959 | 836 | 1.17 / 1618.97 | 5 | 20 |
3 | 13 | 904.68 | 36 | 8.60 | 904 | 280 | 1.45 / 1619.25 | 5 | 23 |
4 | 13 | 500.72 | 36 | 9.55 | 626 | 215 | 1.67 / 1619.46 | 5 | 26 |
5 | 13 | 91.52 | 36 | 10.46 | 323 | 122 | 1.79 / 1619.58 | 6 | 24 |
6 | 13 | 46.84 | 36 | 10.56 | 288 | 109 | 1.90 / 1619.69 | 6 | 24 |
7 | 8 | 0.16 | 450 | 10.70 | 247 | 1189 | 3.09 / 1620.88 | 6 | 39 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 98 | 10.61 | 315 | 328 | 0.33 / 1615.04 | 6 | 8 |
2 | 7 | 1024.24 | 105 | 8.34 | 960 | 841 | 1.17 / 1615.88 | 5 | 20 |
3 | 13 | 826.64 | 36 | 8.81 | 856 | 271 | 1.44 / 1616.15 | 5 | 24 |
4 | 13 | 527.88 | 36 | 9.50 | 646 | 221 | 1.66 / 1616.37 | 5 | 27 |
5 | 13 | 119.24 | 36 | 10.43 | 340 | 128 | 1.79 / 1616.50 | 6 | 25 |
6 | 13 | 29.44 | 36 | 10.61 | 272 | 104 | 1.89 / 1616.61 | 6 | 24 |
7 | 8 | 0.08 | 450 | 10.72 | 246 | 1187 | 3.08 / 1617.79 | 6 | 44 |
Average= | 5.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 98 | 10.68 | 314 | 329 | 0.33 / 1611.91 | 6 | 8 |
2 | 7 | 1022.08 | 105 | 8.38 | 970 | 854 | 1.18 / 1612.76 | 8 | 20 |
3 | 13 | 925.96 | 36 | 8.70 | 920 | 288 | 1.47 / 1613.05 | 5 | 23 |
4 | 13 | 425.92 | 36 | 9.77 | 574 | 202 | 1.67 / 1613.25 | 5 | 27 |
5 | 13 | 230.96 | 36 | 10.22 | 427 | 157 | 1.83 / 1613.41 | 5 | 26 |
6 | 13 | 60.96 | 36 | 10.57 | 296 | 113 | 1.94 / 1613.52 | 6 | 24 |
7 | 8 | 0.16 | 450 | 10.72 | 247 | 1192 | 3.13 / 1614.71 | 6 | 43 |
Average= | 5.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 97 | 10.58 | 328 | 337 | 0.34 / 1606.19 | 6 | 8 |
2 | 3 | 1014.92 | 1 | 8.99 | 965 | 9 | 0.35 / 1606.20 | 5 | 5 |
3 | 7 | 2004.16 | 105 | 6.50 | 1600 | 1092 | 1.44 / 1607.29 | 5 | 6 |
4 | 13 | 1962.60 | 36 | 6.82 | 1587 | 390 | 1.83 / 1607.68 | 5 | 8 |
5 | 13 | 1914.92 | 36 | 6.87 | 1563 | 387 | 2.21 / 1608.07 | 5 | 10 |
6 | 13 | 1857.76 | 36 | 6.93 | 1532 | 382 | 2.60 / 1608.45 | 5 | 12 |
7 | 13 | 1775.28 | 36 | 7.16 | 1473 | 380 | 2.98 / 1608.83 | 5 | 15 |
8 | 13 | 1465.04 | 36 | 7.72 | 1278 | 355 | 3.33 / 1609.19 | 5 | 19 |
9 | 13 | 1372.28 | 36 | 7.91 | 1223 | 348 | 3.68 / 1609.53 | 5 | 21 |
10 | 13 | 973.96 | 36 | 8.63 | 963 | 299 | 3.98 / 1609.83 | 5 | 26 |
11 | 13 | 771.16 | 36 | 9.05 | 821 | 267 | 4.25 / 1610.10 | 5 | 30 |
12 | 13 | 565.88 | 36 | 9.52 | 672 | 230 | 4.48 / 1610.33 | 5 | 30 |
13 | 13 | 65.88 | 36 | 10.60 | 295 | 113 | 4.59 / 1610.44 | 6 | 26 |
14 | 8 | 0.08 | 435 | 10.76 | 243 | 1137 | 5.73 / 1611.58 | 6 | 37 |
Average= | 5.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 98 | 10.68 | 317 | 332 | 0.33 / 1603.05 | 6 | 8 |
2 | 7 | 1010.48 | 105 | 8.43 | 952 | 843 | 1.17 / 1603.89 | 5 | 21 |
3 | 13 | 914.40 | 36 | 8.70 | 915 | 287 | 1.46 / 1604.18 | 5 | 23 |
4 | 13 | 708.92 | 36 | 9.15 | 771 | 254 | 1.71 / 1604.43 | 5 | 27 |
5 | 13 | 175.80 | 36 | 10.34 | 379 | 141 | 1.86 / 1604.58 | 6 | 25 |
6 | 13 | 41.88 | 36 | 10.63 | 276 | 106 | 1.96 / 1604.68 | 6 | 25 |
7 | 8 | 0.24 | 450 | 10.74 | 243 | 1174 | 3.14 / 1605.86 | 6 | 32 |
Average= | 5.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 98 | 10.68 | 317 | 332 | 0.33 / 1599.91 | 6 | 8 |
2 | 7 | 1002.20 | 105 | 8.46 | 960 | 853 | 1.18 / 1600.76 | 8 | 21 |
3 | 13 | 900.84 | 36 | 8.77 | 911 | 288 | 1.47 / 1601.05 | 5 | 24 |
4 | 13 | 608.64 | 36 | 9.39 | 709 | 240 | 1.71 / 1601.29 | 5 | 27 |
5 | 13 | 184.84 | 36 | 10.34 | 389 | 145 | 1.86 / 1601.44 | 5 | 26 |
6 | 13 | 47.08 | 36 | 10.64 | 283 | 108 | 1.97 / 1601.54 | 6 | 24 |
7 | 8 | 0.04 | 450 | 10.75 | 243 | 1176 | 3.14 / 1602.72 | 6 | 40 |
Average= | 5.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 97 | 10.73 | 323 | 336 | 0.34 / 1596.77 | 6 | 8 |
2 | 3 | 1015.92 | 1 | 9.15 | 973 | 9 | 0.35 / 1596.78 | 5 | 5 |
3 | 7 | 1024.40 | 105 | 8.50 | 983 | 877 | 1.22 / 1597.65 | 5 | 21 |
4 | 13 | 928.52 | 36 | 8.78 | 926 | 293 | 1.52 / 1597.95 | 5 | 23 |
5 | 13 | 516.24 | 36 | 9.66 | 635 | 221 | 1.74 / 1598.17 | 5 | 28 |
6 | 13 | 100.36 | 36 | 10.53 | 324 | 123 | 1.86 / 1598.29 | 6 | 25 |
7 | 13 | 53.88 | 36 | 10.62 | 289 | 110 | 1.97 / 1598.40 | 6 | 25 |
8 | 8 | 0.08 | 450 | 10.76 | 243 | 1177 | 3.15 / 1599.58 | 6 | 37 |
Average= | 5.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 95 | 10.69 | 322 | 327 | 0.33 / 1590.97 | 6 | 8 |
2 | 3 | 1042.76 | 2 | 8.97 | 992 | 18 | 0.34 / 1590.99 | 5 | 9 |
3 | 7 | 2002.60 | 105 | 6.64 | 1602 | 1117 | 1.46 / 1592.10 | 9 | 6 |
4 | 13 | 1964.16 | 36 | 6.85 | 1591 | 392 | 1.85 / 1592.50 | 5 | 9 |
5 | 13 | 1903.04 | 36 | 7.09 | 1551 | 396 | 2.25 / 1592.89 | 5 | 10 |
6 | 13 | 1818.80 | 36 | 7.23 | 1506 | 392 | 2.64 / 1593.29 | 5 | 12 |
7 | 13 | 1630.00 | 36 | 7.63 | 1384 | 380 | 3.02 / 1593.67 | 5 | 17 |
8 | 13 | 1539.52 | 36 | 7.77 | 1333 | 373 | 3.39 / 1594.04 | 5 | 19 |
9 | 13 | 1336.16 | 36 | 8.14 | 1202 | 352 | 3.75 / 1594.39 | 5 | 22 |
10 | 13 | 1029.92 | 36 | 8.71 | 1003 | 315 | 4.06 / 1594.70 | 5 | 27 |
11 | 13 | 631.56 | 36 | 9.50 | 724 | 248 | 4.31 / 1594.95 | 5 | 30 |
12 | 13 | 416.76 | 36 | 9.95 | 564 | 202 | 4.51 / 1595.15 | 5 | 30 |
13 | 13 | 41.72 | 36 | 10.67 | 283 | 109 | 4.62 / 1595.26 | 6 | 26 |
14 | 13 | 21.68 | 36 | 10.70 | 269 | 104 | 4.72 / 1595.37 | 6 | 28 |
15 | 8 | 0.04 | 399 | 10.77 | 248 | 1066 | 5.79 / 1596.43 | 6 | 41 |
Average= | 5.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 98 | 10.79 | 305 | 323 | 0.32 / 1587.89 | 6 | 8 |
2 | 7 | 1001.80 | 105 | 8.64 | 962 | 873 | 1.20 / 1588.77 | 8 | 21 |
3 | 13 | 906.20 | 36 | 8.94 | 905 | 291 | 1.49 / 1589.06 | 5 | 23 |
4 | 13 | 393.36 | 36 | 9.96 | 545 | 195 | 1.68 / 1589.25 | 5 | 26 |
5 | 13 | 94.16 | 36 | 10.55 | 319 | 121 | 1.80 / 1589.37 | 6 | 25 |
6 | 13 | 24.28 | 36 | 10.70 | 263 | 101 | 1.90 / 1589.48 | 6 | 24 |
7 | 8 | 0.16 | 450 | 10.76 | 241 | 1167 | 3.07 / 1590.64 | 6 | 38 |
Average= | 5.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 91 | 10.73 | 321 | 313 | 0.31 / 1584.60 | 6 | 8 |
2 | 10 | 1003.84 | 6 | 9.36 | 983 | 55 | 0.37 / 1584.66 | 5 | 11 |
3 | 3 | 1040.08 | 2 | 9.34 | 999 | 19 | 0.39 / 1584.68 | 5 | 9 |
4 | 7 | 1034.08 | 105 | 8.79 | 974 | 899 | 1.29 / 1585.58 | 9 | 22 |
5 | 13 | 835.48 | 36 | 9.27 | 857 | 286 | 1.57 / 1585.86 | 5 | 25 |
6 | 13 | 531.80 | 36 | 9.79 | 644 | 227 | 1.80 / 1586.09 | 5 | 27 |
7 | 13 | 336.76 | 36 | 10.17 | 496 | 182 | 1.98 / 1586.27 | 5 | 26 |
8 | 13 | 168.68 | 36 | 10.50 | 369 | 139 | 2.12 / 1586.41 | 6 | 25 |
9 | 8 | 0.16 | 450 | 10.80 | 239 | 1162 | 3.28 / 1587.57 | 6 | 36 |
Average= | 5.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 75 | 10.83 | 317 | 257 | 0.26 / 1581.13 | 6 | 7 |
2 | 10 | 1041.36 | 8 | 9.65 | 1006 | 78 | 0.34 / 1581.21 | 5 | 12 |
3 | 10 | 1082.88 | 8 | 9.50 | 1050 | 80 | 0.41 / 1581.29 | 5 | 12 |
4 | 3 | 1136.16 | 7 | 9.33 | 1088 | 71 | 0.49 / 1581.36 | 5 | 18 |
5 | 7 | 1081.48 | 105 | 8.96 | 1017 | 957 | 1.44 / 1582.32 | 18 | 22 |
6 | 13 | 976.64 | 36 | 9.16 | 963 | 318 | 1.76 / 1582.64 | 5 | 25 |
7 | 13 | 557.28 | 36 | 9.90 | 665 | 237 | 2.00 / 1582.87 | 5 | 28 |
8 | 13 | 67.20 | 36 | 10.72 | 297 | 115 | 2.11 / 1582.99 | 6 | 23 |
9 | 13 | 37.24 | 36 | 10.77 | 280 | 109 | 2.22 / 1583.10 | 6 | 25 |
10 | 8 | -0.04 | 450 | 10.82 | 245 | 1193 | 3.41 / 1584.29 | 6 | 32 |
Average= | 5.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 73 | 11.05 | 318 | 257 | 0.26 / 1574.91 | 6 | 7 |
2 | 10 | 1048.76 | 9 | 9.79 | 1021 | 90 | 0.35 / 1575.00 | 5 | 11 |
3 | 10 | 1082.28 | 6 | 9.74 | 1045 | 61 | 0.41 / 1575.06 | 5 | 12 |
4 | 3 | 1138.52 | 7 | 9.59 | 1061 | 71 | 0.48 / 1575.13 | 5 | 19 |
5 | 7 | 2005.36 | 120 | 5.64 | 1587 | 1074 | 1.55 / 1576.21 | 19 | 6 |
6 | 13 | 2008.68 | 36 | 7.13 | 1627 | 418 | 1.97 / 1576.62 | 5 | 6 |
7 | 13 | 1960.40 | 36 | 7.46 | 1602 | 430 | 2.40 / 1577.05 | 5 | 9 |
8 | 13 | 1888.80 | 36 | 7.68 | 1562 | 432 | 2.83 / 1577.49 | 5 | 13 |
9 | 13 | 1806.48 | 36 | 8.00 | 1509 | 435 | 3.27 / 1577.92 | 5 | 16 |
10 | 13 | 1717.36 | 36 | 8.17 | 1461 | 430 | 3.70 / 1578.35 | 5 | 19 |
11 | 13 | 1421.84 | 36 | 8.71 | 1268 | 398 | 4.09 / 1578.75 | 5 | 24 |
12 | 13 | 1222.64 | 36 | 9.03 | 1137 | 370 | 4.46 / 1579.12 | 5 | 27 |
13 | 13 | 910.56 | 36 | 9.48 | 931 | 318 | 4.78 / 1579.44 | 5 | 31 |
14 | 13 | 389.36 | 36 | 10.35 | 550 | 205 | 4.99 / 1579.64 | 5 | 30 |
15 | 13 | 45.44 | 36 | 10.87 | 284 | 111 | 5.10 / 1579.75 | 6 | 26 |
16 | 8 | 0.08 | 420 | 10.89 | 246 | 1125 | 6.22 / 1580.88 | 6 | 38 |
Average= | 5.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 83 | 11.39 | 326 | 308 | 0.31 / 1571.73 | 6 | 8 |
2 | 10 | 1023.96 | 5 | 10.58 | 1021 | 54 | 0.36 / 1571.78 | 5 | 15 |
3 | 3 | 1046.16 | 2 | 10.50 | 1033 | 22 | 0.38 / 1571.81 | 5 | 13 |
4 | 7 | 1029.12 | 105 | 7.84 | 971 | 799 | 1.18 / 1572.60 | 13 | 15 |
5 | 13 | 836.40 | 36 | 9.23 | 865 | 287 | 1.47 / 1572.89 | 5 | 24 |
6 | 13 | 543.92 | 36 | 9.97 | 656 | 235 | 1.71 / 1573.13 | 5 | 28 |
7 | 13 | 446.28 | 36 | 10.19 | 582 | 214 | 1.92 / 1573.34 | 5 | 29 |
8 | 13 | 22.84 | 36 | 11.11 | 264 | 106 | 2.03 / 1573.45 | 6 | 26 |
9 | 8 | 0.08 | 450 | 11.04 | 243 | 1207 | 3.23 / 1574.65 | 6 | 46 |
Average= | 5.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 74 | 12.09 | 326 | 292 | 0.29 / 1568.29 | 6 | 9 |
2 | 10 | 1011.60 | 6 | 11.66 | 1025 | 72 | 0.36 / 1568.37 | 5 | 17 |
3 | 3 | 1088.36 | 4 | 11.66 | 1058 | 49 | 0.41 / 1568.41 | 5 | 24 |
4 | 7 | 1056.84 | 105 | 8.66 | 988 | 898 | 1.31 / 1569.31 | 24 | 19 |
5 | 13 | 867.12 | 36 | 9.92 | 891 | 318 | 1.63 / 1569.63 | 5 | 28 |
6 | 13 | 457.60 | 36 | 10.79 | 598 | 232 | 1.86 / 1569.86 | 5 | 31 |
7 | 13 | 251.08 | 36 | 11.15 | 447 | 179 | 2.04 / 1570.04 | 5 | 30 |
8 | 13 | 13.88 | 36 | 11.59 | 263 | 110 | 2.15 / 1570.15 | 6 | 28 |
9 | 8 | 0.12 | 450 | 11.41 | 247 | 1268 | 3.42 / 1571.42 | 6 | 41 |
Average= | 5.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 71 | 13.33 | 336 | 318 | 0.32 / 1564.88 | 6 | 11 |
2 | 3 | 1084.64 | 4 | 12.72 | 1103 | 56 | 0.37 / 1564.93 | 5 | 31 |
3 | 7 | 1044.36 | 105 | 9.20 | 992 | 958 | 1.33 / 1565.89 | 31 | 23 |
4 | 13 | 840.72 | 36 | 10.65 | 884 | 339 | 1.67 / 1566.23 | 5 | 32 |
5 | 13 | 517.04 | 36 | 11.36 | 654 | 267 | 1.94 / 1566.50 | 5 | 35 |
6 | 13 | 50.04 | 36 | 12.44 | 299 | 134 | 2.07 / 1566.63 | 6 | 32 |
7 | 8 | 0.12 | 450 | 12.08 | 252 | 1370 | 3.44 / 1568.00 | 6 | 47 |
Average= | 5.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 73 | 13.86 | 334 | 338 | 0.34 / 1558.06 | 6 | 13 |
2 | 3 | 1014.60 | 1 | 12.13 | 1015 | 12 | 0.35 / 1558.07 | 5 | 5 |
3 | 7 | 2002.48 | 105 | 4.30 | 1114 | 503 | 0.85 / 1558.57 | 5 | 7 |
4 | 13 | 2071.96 | 36 | 7.04 | 1644 | 417 | 1.27 / 1558.99 | 5 | 6 |
5 | 13 | 2108.00 | 36 | 8.10 | 1719 | 501 | 1.77 / 1559.49 | 5 | 5 |
6 | 13 | 2077.84 | 36 | 9.05 | 1706 | 556 | 2.33 / 1560.05 | 5 | 13 |
7 | 13 | 2013.04 | 36 | 9.66 | 1682 | 585 | 2.91 / 1560.63 | 5 | 24 |
8 | 13 | 1921.76 | 36 | 10.11 | 1624 | 591 | 3.50 / 1561.22 | 5 | 28 |
9 | 13 | 1716.24 | 36 | 10.49 | 1495 | 565 | 4.07 / 1561.79 | 5 | 32 |
10 | 13 | 1402.92 | 36 | 10.99 | 1288 | 510 | 4.58 / 1562.30 | 5 | 38 |
11 | 13 | 860.96 | 36 | 11.82 | 925 | 394 | 4.97 / 1562.69 | 5 | 44 |
12 | 13 | 421.72 | 36 | 12.62 | 602 | 274 | 5.24 / 1562.96 | 5 | 42 |
13 | 13 | 41.44 | 36 | 13.40 | 302 | 146 | 5.39 / 1563.11 | 6 | 36 |
14 | 8 | -0.04 | 435 | 12.88 | 259 | 1451 | 6.84 / 1564.56 | 6 | 50 |
Average= | 5.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 74 | 13.92 | 342 | 352 | 0.35 / 1554.46 | 6 | 14 |
2 | 7 | 1002.96 | 105 | 6.49 | 923 | 629 | 0.98 / 1555.09 | 5 | 12 |
3 | 13 | 925.96 | 36 | 10.76 | 948 | 367 | 1.35 / 1555.46 | 5 | 29 |
4 | 13 | 737.36 | 36 | 11.92 | 826 | 354 | 1.70 / 1555.81 | 5 | 38 |
5 | 13 | 112.68 | 36 | 13.85 | 364 | 181 | 1.88 / 1555.99 | 6 | 37 |
6 | 13 | 13.00 | 36 | 14.10 | 285 | 145 | 2.03 / 1556.14 | 6 | 37 |
7 | 8 | 0.12 | 450 | 13.35 | 263 | 1580 | 3.61 / 1557.72 | 6 | 49 |
Average= | 5.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 72 | 14.02 | 337 | 340 | 0.34 / 1550.87 | 6 | 14 |
2 | 3 | 1025.52 | 1 | 12.23 | 1007 | 12 | 0.35 / 1550.88 | 5 | 10 |
3 | 7 | 1010.04 | 106 | 7.71 | 940 | 768 | 1.12 / 1551.65 | 10 | 18 |
4 | 13 | 909.92 | 36 | 11.28 | 943 | 383 | 1.50 / 1552.03 | 5 | 33 |
5 | 13 | 500.12 | 36 | 13.08 | 659 | 310 | 1.81 / 1552.34 | 5 | 42 |
6 | 13 | 77.88 | 36 | 13.98 | 336 | 169 | 1.98 / 1552.51 | 6 | 38 |
7 | 8 | 0.16 | 450 | 13.58 | 262 | 1601 | 3.58 / 1554.11 | 6 | 51 |
Average= | 5.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 70 | 14.18 | 338 | 335 | 0.34 / 1547.21 | 6 | 15 |
2 | 3 | 1012.44 | 1 | 12.19 | 1019 | 12 | 0.35 / 1547.22 | 5 | 5 |
3 | 7 | 1015.52 | 105 | 8.96 | 976 | 918 | 1.27 / 1548.14 | 5 | 23 |
4 | 13 | 919.28 | 36 | 11.71 | 950 | 400 | 1.67 / 1548.54 | 5 | 37 |
5 | 13 | 606.36 | 36 | 13.03 | 735 | 345 | 2.01 / 1548.89 | 5 | 44 |
6 | 8 | 0.12 | 450 | 13.80 | 264 | 1639 | 3.65 / 1550.53 | 6 | 54 |
Average= | 5.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 71 | 14.10 | 347 | 347 | 0.35 / 1540.14 | 6 | 15 |
2 | 3 | 1038.40 | 2 | 12.29 | 1038 | 26 | 0.37 / 1540.17 | 5 | 16 |
3 | 7 | 2004.40 | 106 | 4.36 | 1375 | 635 | 1.01 / 1540.80 | 16 | 6 |
4 | 13 | 2074.16 | 36 | 10.35 | 1698 | 633 | 1.64 / 1541.44 | 5 | 5 |
5 | 13 | 2056.24 | 36 | 10.44 | 1715 | 645 | 2.29 / 1542.08 | 5 | 17 |
6 | 13 | 1995.16 | 36 | 10.89 | 1681 | 659 | 2.94 / 1542.74 | 5 | 29 |
7 | 13 | 1913.44 | 36 | 11.29 | 1627 | 661 | 3.61 / 1543.40 | 5 | 32 |
8 | 13 | 1819.60 | 36 | 11.56 | 1573 | 655 | 4.26 / 1544.06 | 5 | 36 |
9 | 13 | 1378.20 | 36 | 12.65 | 1289 | 587 | 4.85 / 1544.64 | 5 | 47 |
10 | 13 | 587.12 | 36 | 13.59 | 729 | 357 | 5.20 / 1545.00 | 5 | 50 |
11 | 13 | 142.20 | 36 | 14.10 | 385 | 195 | 5.40 / 1545.20 | 6 | 42 |
12 | 8 | 0.08 | 450 | 14.03 | 266 | 1679 | 7.08 / 1546.87 | 6 | 47 |
Average= | 5.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 72 | 14.20 | 342 | 350 | 0.35 / 1536.44 | 6 | 18 |
2 | 7 | 1019.08 | 106 | 7.68 | 942 | 767 | 1.12 / 1537.21 | 5 | 16 |
3 | 13 | 930.20 | 36 | 11.98 | 959 | 414 | 1.53 / 1537.62 | 5 | 36 |
4 | 13 | 510.44 | 36 | 13.25 | 666 | 318 | 1.85 / 1537.94 | 5 | 43 |
5 | 13 | 82.56 | 36 | 14.12 | 336 | 171 | 2.02 / 1538.11 | 6 | 38 |
6 | 8 | 0.12 | 450 | 14.04 | 267 | 1687 | 3.71 / 1539.80 | 6 | 56 |
Average= | 5.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 72 | 14.26 | 334 | 343 | 0.34 / 1532.85 | 6 | 15 |
2 | 3 | 1011.00 | 1 | 11.67 | 1009 | 12 | 0.35 / 1532.86 | 5 | 5 |
3 | 7 | 1000.40 | 105 | 7.93 | 941 | 784 | 1.14 / 1533.64 | 5 | 18 |
4 | 13 | 904.84 | 36 | 12.15 | 943 | 412 | 1.55 / 1534.05 | 5 | 36 |
5 | 13 | 576.44 | 36 | 13.24 | 715 | 341 | 1.89 / 1534.39 | 5 | 43 |
6 | 8 | 0.24 | 450 | 14.11 | 267 | 1695 | 3.59 / 1536.09 | 6 | 59 |
Average= | 5.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 69 | 14.28 | 350 | 345 | 0.34 / 1529.16 | 6 | 15 |
2 | 3 | 1026.96 | 1 | 12.38 | 1014 | 13 | 0.36 / 1529.17 | 5 | 10 |
3 | 7 | 1011.92 | 105 | 8.96 | 968 | 911 | 1.27 / 1530.08 | 10 | 22 |
4 | 13 | 915.72 | 36 | 12.30 | 954 | 422 | 1.69 / 1530.50 | 5 | 38 |
5 | 13 | 380.84 | 36 | 13.75 | 575 | 285 | 1.98 / 1530.79 | 5 | 43 |
6 | 8 | -0.04 | 450 | 14.18 | 269 | 1716 | 3.69 / 1532.50 | 6 | 55 |
Average= | 5.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 69 | 14.31 | 339 | 335 | 0.33 / 1522.20 | 6 | 15 |
2 | 3 | 1045.92 | 2 | 12.13 | 1043 | 25 | 0.36 / 1522.23 | 5 | 17 |
3 | 7 | 2002.16 | 105 | 4.35 | 1339 | 612 | 0.97 / 1522.84 | 17 | 7 |
4 | 13 | 2080.12 | 36 | 10.84 | 1709 | 667 | 1.64 / 1523.51 | 5 | 6 |
5 | 13 | 2061.64 | 36 | 11.04 | 1726 | 686 | 2.32 / 1524.19 | 5 | 23 |
6 | 13 | 2000.48 | 36 | 11.52 | 1689 | 700 | 3.02 / 1524.89 | 5 | 33 |
7 | 13 | 1913.12 | 36 | 11.89 | 1643 | 703 | 3.73 / 1525.60 | 5 | 36 |
8 | 13 | 1405.48 | 36 | 12.87 | 1308 | 606 | 4.33 / 1526.20 | 5 | 47 |
9 | 13 | 1199.52 | 36 | 13.12 | 1178 | 556 | 4.89 / 1526.76 | 5 | 50 |
10 | 13 | 426.20 | 36 | 13.91 | 614 | 307 | 5.20 / 1527.06 | 5 | 47 |
11 | 8 | 0.08 | 450 | 14.27 | 272 | 1747 | 6.94 / 1528.81 | 6 | 49 |
Average= | 5.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 72 | 14.19 | 341 | 348 | 0.35 / 1518.32 | 6 | 17 |
2 | 7 | 1013.60 | 106 | 7.37 | 949 | 741 | 1.09 / 1519.07 | 17 | 16 |
3 | 13 | 918.80 | 36 | 12.22 | 957 | 421 | 1.51 / 1519.49 | 5 | 38 |
4 | 13 | 708.44 | 36 | 12.96 | 818 | 382 | 1.89 / 1519.87 | 5 | 43 |
5 | 13 | 364.80 | 36 | 13.77 | 559 | 277 | 2.17 / 1520.15 | 5 | 44 |
6 | 8 | 0.00 | 450 | 14.22 | 269 | 1721 | 3.89 / 1521.87 | 6 | 58 |
Average= | 5.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 72 | 14.26 | 342 | 351 | 0.35 / 1514.73 | 6 | 18 |
2 | 7 | 977.84 | 105 | 7.88 | 932 | 771 | 1.12 / 1515.50 | 18 | 18 |
3 | 13 | 891.44 | 36 | 12.35 | 940 | 418 | 1.54 / 1515.92 | 5 | 37 |
4 | 13 | 571.92 | 36 | 13.38 | 709 | 342 | 1.88 / 1516.26 | 5 | 44 |
5 | 8 | 0.16 | 450 | 14.25 | 268 | 1719 | 3.60 / 1517.98 | 6 | 55 |
Average= | 5.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 69 | 14.35 | 340 | 337 | 0.34 / 1511.08 | 6 | 16 |
2 | 7 | 986.88 | 105 | 9.08 | 951 | 907 | 1.24 / 1511.99 | 16 | 24 |
3 | 13 | 785.88 | 36 | 12.91 | 872 | 405 | 1.65 / 1512.39 | 5 | 42 |
4 | 13 | 274.24 | 36 | 14.00 | 490 | 247 | 1.90 / 1512.64 | 5 | 42 |
5 | 8 | 0.16 | 450 | 14.27 | 270 | 1734 | 3.63 / 1514.38 | 6 | 54 |
Average= | 5.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 72 | 14.26 | 340 | 349 | 0.35 / 1504.07 | 6 | 19 |
2 | 3 | 964.84 | -1 | 14.26 | 340 | 0 | 0.00 / 1504.07 | 6 | 19 |
3 | 7 | 2002.32 | 105 | 4.37 | 1402 | 643 | 0.99 / 1504.72 | 19 | 6 |
4 | 13 | 2083.44 | 36 | 11.16 | 1730 | 695 | 1.69 / 1505.41 | 5 | 7 |
5 | 13 | 2055.48 | 36 | 11.36 | 1736 | 710 | 2.40 / 1506.12 | 5 | 27 |
6 | 13 | 1984.28 | 36 | 11.81 | 1683 | 716 | 3.11 / 1506.84 | 5 | 35 |
7 | 13 | 1899.88 | 36 | 12.17 | 1631 | 715 | 3.83 / 1507.55 | 5 | 39 |
8 | 13 | 1803.72 | 36 | 12.46 | 1576 | 707 | 4.53 / 1508.26 | 5 | 42 |
9 | 13 | 803.88 | 36 | 13.59 | 889 | 435 | 4.97 / 1508.69 | 5 | 53 |
10 | 13 | 394.32 | 36 | 13.98 | 588 | 296 | 5.27 / 1508.99 | 5 | 47 |
11 | 8 | 0.08 | 450 | 14.30 | 273 | 1757 | 7.02 / 1510.75 | 12 | 64 |
Average= | 5.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 72 | 14.23 | 347 | 356 | 0.36 / 1500.46 | 6 | 18 |
2 | 7 | 998.12 | 106 | 7.84 | 942 | 783 | 1.14 / 1501.24 | 18 | 18 |
3 | 13 | 898.00 | 36 | 12.40 | 943 | 421 | 1.56 / 1501.66 | 5 | 39 |
4 | 13 | 482.12 | 36 | 13.60 | 647 | 317 | 1.88 / 1501.98 | 5 | 44 |
5 | 8 | 0.16 | 450 | 14.25 | 272 | 1744 | 3.62 / 1503.72 | 6 | 48 |
Average= | 5.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 72 | 14.23 | 353 | 362 | 0.36 / 1496.84 | 6 | 17 |
2 | 7 | 981.92 | 105 | 8.39 | 937 | 825 | 1.19 / 1497.67 | 17 | 21 |
3 | 13 | 878.84 | 36 | 12.53 | 928 | 419 | 1.61 / 1498.09 | 5 | 40 |
4 | 13 | 366.48 | 36 | 13.85 | 559 | 279 | 1.88 / 1498.36 | 5 | 44 |
5 | 8 | 0.16 | 450 | 14.27 | 271 | 1740 | 3.62 / 1500.10 | 6 | 48 |
Average= | 5.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 68 | 14.27 | 352 | 342 | 0.34 / 1492.97 | 6 | 16 |
2 | 3 | 1016.64 | 1 | 11.86 | 1017 | 12 | 0.35 / 1492.98 | 5 | 6 |
3 | 7 | 1020.36 | 105 | 9.11 | 974 | 932 | 1.29 / 1493.91 | 6 | 25 |
4 | 13 | 921.48 | 36 | 12.61 | 963 | 437 | 1.72 / 1494.35 | 5 | 41 |
5 | 13 | 282.32 | 36 | 14.01 | 496 | 250 | 1.97 / 1494.60 | 5 | 42 |
6 | 13 | 16.28 | 36 | 14.30 | 290 | 149 | 2.12 / 1494.75 | 6 | 38 |
7 | 8 | 0.12 | 450 | 14.30 | 269 | 1731 | 3.85 / 1496.48 | 6 | 65 |
Average= | 5.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 72 | 14.22 | 344 | 352 | 0.35 / 1485.88 | 6 | 16 |
2 | 7 | 2013.00 | 106 | 4.39 | 1475 | 686 | 1.04 / 1486.57 | 16 | 6 |
3 | 13 | 2089.44 | 36 | 11.42 | 1747 | 718 | 1.76 / 1487.28 | 5 | 8 |
4 | 13 | 2068.80 | 36 | 11.69 | 1738 | 731 | 2.49 / 1488.01 | 5 | 29 |
5 | 13 | 2010.20 | 36 | 11.99 | 1703 | 735 | 3.22 / 1488.75 | 5 | 35 |
6 | 13 | 1920.00 | 36 | 12.32 | 1650 | 732 | 3.96 / 1489.48 | 5 | 40 |
7 | 13 | 1397.24 | 36 | 13.16 | 1314 | 623 | 4.58 / 1490.10 | 5 | 49 |
8 | 13 | 859.80 | 36 | 13.59 | 943 | 461 | 5.04 / 1490.57 | 5 | 53 |
9 | 13 | 425.12 | 36 | 13.97 | 610 | 307 | 5.35 / 1490.87 | 5 | 50 |
10 | 8 | 0.08 | 450 | 14.33 | 272 | 1754 | 7.10 / 1492.63 | 6 | 58 |
Average= | 5.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 72 | 14.27 | 343 | 352 | 0.35 / 1482.08 | 6 | 17 |
2 | 7 | 990.68 | 106 | 8.09 | 940 | 806 | 1.16 / 1482.88 | 17 | 19 |
3 | 13 | 889.32 | 36 | 12.54 | 937 | 423 | 1.58 / 1483.31 | 5 | 39 |
4 | 13 | 458.40 | 36 | 13.68 | 630 | 310 | 1.89 / 1483.62 | 5 | 45 |
5 | 13 | 54.64 | 36 | 14.21 | 318 | 163 | 2.05 / 1483.78 | 6 | 40 |
6 | 8 | 0.12 | 450 | 14.28 | 272 | 1748 | 3.80 / 1485.53 | 6 | 57 |
Average= | 5.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 72 | 14.29 | 338 | 348 | 0.35 / 1478.45 | 6 | 18 |
2 | 7 | 993.32 | 105 | 8.35 | 949 | 832 | 1.18 / 1479.29 | 18 | 22 |
3 | 13 | 893.68 | 36 | 12.58 | 951 | 431 | 1.61 / 1479.72 | 5 | 41 |
4 | 13 | 379.28 | 36 | 13.84 | 572 | 285 | 1.90 / 1480.00 | 5 | 45 |
5 | 8 | 0.16 | 450 | 14.29 | 268 | 1723 | 3.62 / 1481.72 | 6 | 47 |
Average= | 6.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 71 | 14.27 | 338 | 342 | 0.34 / 1474.79 | 6 | 16 |
2 | 3 | 950.48 | -1 | 14.27 | 338 | 0 | 0.00 / 1474.79 | 6 | 16 |
3 | 7 | 1007.64 | 105 | 9.22 | 971 | 940 | 1.28 / 1475.74 | 16 | 25 |
4 | 13 | 799.52 | 36 | 13.15 | 887 | 420 | 1.70 / 1476.15 | 5 | 44 |
5 | 13 | 173.92 | 36 | 14.15 | 416 | 212 | 1.91 / 1476.37 | 5 | 41 |
6 | 8 | 0.24 | 450 | 14.31 | 270 | 1739 | 3.65 / 1478.11 | 6 | 58 |
Average= | 6.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 72 | 14.25 | 343 | 352 | 0.35 / 1467.90 | 6 | 15 |
2 | 7 | 2001.84 | 106 | 4.87 | 1516 | 783 | 1.13 / 1468.69 | 15 | 5 |
3 | 13 | 2044.52 | 36 | 11.67 | 1729 | 726 | 1.86 / 1469.41 | 5 | 20 |
4 | 13 | 1989.28 | 36 | 11.87 | 1699 | 726 | 2.59 / 1470.14 | 5 | 35 |
5 | 13 | 1905.68 | 36 | 12.23 | 1646 | 725 | 3.31 / 1470.86 | 5 | 39 |
6 | 13 | 1807.48 | 36 | 12.52 | 1584 | 714 | 4.03 / 1471.58 | 5 | 43 |
7 | 13 | 1256.12 | 36 | 13.29 | 1225 | 586 | 4.61 / 1472.16 | 5 | 52 |
8 | 13 | 600.88 | 36 | 13.82 | 750 | 373 | 4.98 / 1472.54 | 5 | 53 |
9 | 13 | 76.56 | 36 | 14.25 | 338 | 173 | 5.16 / 1472.71 | 6 | 40 |
10 | 8 | -0.12 | 450 | 14.34 | 270 | 1742 | 6.90 / 1474.45 | 6 | 59 |
Average= | 6.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 72 | 14.24 | 348 | 357 | 0.36 / 1464.11 | 6 | 15 |
2 | 7 | 1006.28 | 105 | 8.30 | 955 | 832 | 1.19 / 1464.94 | 15 | 21 |
3 | 13 | 905.96 | 36 | 12.64 | 953 | 434 | 1.62 / 1465.38 | 5 | 40 |
4 | 13 | 381.36 | 36 | 13.84 | 576 | 287 | 1.91 / 1465.66 | 5 | 44 |
5 | 13 | 38.52 | 36 | 14.23 | 308 | 158 | 2.07 / 1465.82 | 6 | 38 |
6 | 8 | -0.04 | 450 | 14.29 | 269 | 1730 | 3.80 / 1467.55 | 6 | 52 |
Average= | 6.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 71 | 14.28 | 342 | 347 | 0.35 / 1460.44 | 6 | 15 |
2 | 7 | 1007.08 | 105 | 8.58 | 951 | 857 | 1.20 / 1461.30 | 5 | 21 |
3 | 13 | 911.44 | 36 | 12.69 | 953 | 435 | 1.64 / 1461.73 | 5 | 40 |
4 | 13 | 382.96 | 36 | 13.91 | 571 | 286 | 1.92 / 1462.02 | 5 | 43 |
5 | 8 | 0.16 | 450 | 14.30 | 270 | 1737 | 3.66 / 1463.75 | 6 | 53 |
Average= | 6.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 71 | 14.34 | 338 | 344 | 0.34 / 1456.69 | 6 | 13 |
2 | 7 | 1005.16 | 106 | 9.24 | 966 | 946 | 1.29 / 1457.64 | 13 | 24 |
3 | 13 | 910.32 | 36 | 12.82 | 956 | 441 | 1.73 / 1458.08 | 5 | 41 |
4 | 13 | 358.88 | 36 | 13.94 | 555 | 279 | 2.01 / 1458.36 | 5 | 44 |
5 | 8 | 0.12 | 450 | 14.31 | 269 | 1732 | 3.74 / 1460.09 | 6 | 52 |
Average= | 6.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 72 | 14.25 | 342 | 351 | 0.35 / 1449.92 | 6 | 14 |
2 | 7 | 2009.16 | 105 | 5.04 | 1511 | 800 | 1.15 / 1450.72 | 14 | 5 |
3 | 13 | 2043.20 | 36 | 11.75 | 1727 | 731 | 1.88 / 1451.45 | 5 | 22 |
4 | 13 | 1984.08 | 36 | 12.06 | 1687 | 732 | 2.61 / 1452.19 | 5 | 36 |
5 | 13 | 1899.16 | 36 | 12.39 | 1632 | 728 | 3.34 / 1452.92 | 5 | 40 |
6 | 13 | 1602.00 | 36 | 12.99 | 1454 | 680 | 4.02 / 1453.60 | 5 | 46 |
7 | 13 | 1069.80 | 36 | 13.51 | 1087 | 529 | 4.55 / 1454.12 | 5 | 53 |
8 | 13 | 442.76 | 36 | 13.94 | 632 | 317 | 4.87 / 1454.44 | 5 | 49 |
9 | 13 | 51.00 | 36 | 14.27 | 325 | 167 | 5.03 / 1454.61 | 6 | 39 |
10 | 8 | 0.16 | 450 | 14.34 | 270 | 1742 | 6.78 / 1456.35 | 6 | 57 |
Average= | 6.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 71 | 14.29 | 337 | 342 | 0.34 / 1446.13 | 6 | 14 |
2 | 7 | 1003.00 | 105 | 8.37 | 954 | 838 | 1.18 / 1446.97 | 14 | 20 |
3 | 13 | 914.40 | 36 | 12.69 | 956 | 437 | 1.62 / 1447.41 | 5 | 40 |
4 | 13 | 380.08 | 36 | 13.87 | 573 | 286 | 1.90 / 1447.70 | 5 | 44 |
5 | 13 | 37.32 | 36 | 14.23 | 305 | 156 | 2.06 / 1447.85 | 6 | 38 |
6 | 8 | -0.04 | 450 | 14.28 | 268 | 1722 | 3.78 / 1449.57 | 6 | 56 |
Average= | 6.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 71 | 14.29 | 347 | 352 | 0.35 / 1442.25 | 6 | 14 |
2 | 7 | 1012.76 | 105 | 8.55 | 961 | 863 | 1.21 / 1443.12 | 5 | 22 |
3 | 13 | 817.40 | 36 | 13.17 | 897 | 425 | 1.64 / 1443.54 | 5 | 42 |
4 | 13 | 603.16 | 36 | 13.60 | 742 | 363 | 2.00 / 1443.90 | 5 | 46 |
5 | 13 | 59.12 | 36 | 14.21 | 323 | 165 | 2.17 / 1444.07 | 6 | 39 |
6 | 8 | 0.12 | 450 | 14.29 | 268 | 1723 | 3.89 / 1445.79 | 6 | 56 |
Average= | 6.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 71 | 14.38 | 338 | 345 | 0.35 / 1438.33 | 6 | 14 |
2 | 7 | 1011.04 | 105 | 9.33 | 973 | 953 | 1.30 / 1439.28 | 5 | 26 |
3 | 13 | 818.24 | 36 | 13.33 | 896 | 430 | 1.73 / 1439.71 | 5 | 44 |
4 | 13 | 373.76 | 36 | 13.94 | 570 | 286 | 2.01 / 1440.00 | 5 | 44 |
5 | 13 | 32.24 | 36 | 14.25 | 307 | 157 | 2.17 / 1440.16 | 6 | 38 |
6 | 8 | 0.12 | 450 | 14.29 | 271 | 1743 | 3.91 / 1441.90 | 6 | 55 |
Average= | 6.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 72 | 14.24 | 332 | 340 | 0.34 / 1431.62 | 6 | 13 |
2 | 7 | 2002.80 | 106 | 5.22 | 1528 | 845 | 1.19 / 1432.46 | 13 | 5 |
3 | 13 | 2027.88 | 36 | 11.93 | 1718 | 738 | 1.92 / 1433.20 | 5 | 29 |
4 | 13 | 1977.28 | 36 | 12.22 | 1679 | 739 | 2.66 / 1433.94 | 5 | 37 |
5 | 13 | 1895.36 | 36 | 12.49 | 1638 | 737 | 3.40 / 1434.68 | 5 | 40 |
6 | 13 | 1468.08 | 36 | 13.18 | 1368 | 649 | 4.05 / 1435.32 | 5 | 48 |
7 | 13 | 934.52 | 36 | 13.59 | 999 | 489 | 4.54 / 1435.81 | 5 | 53 |
8 | 13 | 276.04 | 36 | 14.07 | 501 | 254 | 4.79 / 1436.07 | 5 | 44 |
9 | 13 | 35.72 | 36 | 14.27 | 313 | 161 | 4.95 / 1436.23 | 6 | 39 |
10 | 8 | 0.08 | 450 | 14.31 | 273 | 1758 | 6.71 / 1437.99 | 6 | 60 |
Average= | 6.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 71 | 14.29 | 343 | 348 | 0.35 / 1427.63 | 6 | 12 |
2 | 7 | 1012.80 | 105 | 8.64 | 955 | 866 | 1.21 / 1428.50 | 5 | 22 |
3 | 13 | 906.88 | 36 | 12.81 | 953 | 439 | 1.65 / 1428.93 | 5 | 41 |
4 | 13 | 485.72 | 36 | 13.77 | 651 | 323 | 1.98 / 1429.26 | 5 | 45 |
5 | 13 | 36.56 | 36 | 14.22 | 304 | 156 | 2.13 / 1429.41 | 6 | 38 |
6 | 13 | 20.12 | 36 | 14.20 | 291 | 149 | 2.28 / 1429.56 | 6 | 38 |
7 | 8 | 0.12 | 450 | 14.27 | 267 | 1715 | 4.00 / 1431.28 | 6 | 57 |
Average= | 6.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 71 | 14.30 | 339 | 344 | 0.34 / 1423.81 | 6 | 13 |
2 | 7 | 1006.88 | 105 | 8.68 | 961 | 876 | 1.22 / 1424.69 | 13 | 22 |
3 | 13 | 808.68 | 36 | 13.24 | 889 | 424 | 1.64 / 1425.11 | 5 | 43 |
4 | 13 | 382.36 | 36 | 13.88 | 572 | 286 | 1.93 / 1425.40 | 5 | 44 |
5 | 13 | 30.60 | 36 | 14.23 | 300 | 154 | 2.08 / 1425.55 | 6 | 38 |
6 | 8 | 0.04 | 450 | 14.27 | 269 | 1727 | 3.81 / 1427.28 | 6 | 54 |
Average= | 6.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 70 | 14.29 | 336 | 336 | 0.34 / 1419.95 | 6 | 13 |
2 | 3 | 1014.44 | 1 | 12.00 | 1009 | 12 | 0.35 / 1419.96 | 5 | 6 |
3 | 7 | 1032.24 | 105 | 9.37 | 976 | 960 | 1.31 / 1420.92 | 6 | 26 |
4 | 13 | 818.40 | 36 | 13.38 | 890 | 429 | 1.74 / 1421.35 | 5 | 45 |
5 | 13 | 272.28 | 36 | 14.04 | 489 | 247 | 1.98 / 1421.60 | 5 | 42 |
6 | 13 | 32.40 | 36 | 14.25 | 298 | 153 | 2.14 / 1421.75 | 6 | 37 |
7 | 8 | 0.08 | 450 | 14.28 | 268 | 1722 | 3.86 / 1423.47 | 6 | 56 |
Average= | 6.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 72 | 14.25 | 341 | 350 | 0.35 / 1413.49 | 6 | 13 |
2 | 7 | 2000.96 | 105 | 5.81 | 1525 | 930 | 1.28 / 1414.42 | 5 | 5 |
3 | 13 | 1976.32 | 36 | 12.13 | 1672 | 730 | 2.01 / 1415.15 | 5 | 33 |
4 | 13 | 1900.92 | 36 | 12.44 | 1627 | 729 | 2.74 / 1415.88 | 5 | 39 |
5 | 13 | 1811.52 | 36 | 12.67 | 1578 | 720 | 3.46 / 1416.60 | 5 | 41 |
6 | 13 | 1393.96 | 36 | 13.27 | 1309 | 625 | 4.08 / 1417.22 | 5 | 49 |
7 | 13 | 845.96 | 36 | 13.67 | 923 | 454 | 4.54 / 1417.68 | 5 | 53 |
8 | 13 | 180.36 | 36 | 14.15 | 421 | 214 | 4.75 / 1417.89 | 5 | 41 |
9 | 8 | 0.12 | 450 | 14.31 | 267 | 1719 | 6.47 / 1419.61 | 6 | 52 |
Average= | 6.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 71 | 14.22 | 338 | 341 | 0.34 / 1409.65 | 6 | 14 |
2 | 7 | 1017.72 | 105 | 8.94 | 975 | 915 | 1.26 / 1410.57 | 14 | 23 |
3 | 13 | 914.36 | 36 | 12.87 | 951 | 441 | 1.70 / 1411.01 | 5 | 41 |
4 | 13 | 385.24 | 36 | 13.88 | 568 | 284 | 1.98 / 1411.29 | 5 | 43 |
5 | 13 | 14.68 | 36 | 14.25 | 281 | 144 | 2.13 / 1411.44 | 6 | 37 |
6 | 8 | 0.04 | 450 | 14.26 | 265 | 1701 | 3.83 / 1413.14 | 6 | 56 |
Average= | 6.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 71 | 14.27 | 342 | 347 | 0.35 / 1405.83 | 6 | 16 |
2 | 7 | 1002.00 | 105 | 8.99 | 970 | 916 | 1.26 / 1406.74 | 16 | 24 |
3 | 13 | 896.56 | 36 | 12.90 | 943 | 438 | 1.70 / 1407.18 | 5 | 41 |
4 | 13 | 361.68 | 36 | 13.91 | 552 | 276 | 1.98 / 1407.46 | 5 | 44 |
5 | 13 | 26.88 | 36 | 14.21 | 293 | 150 | 2.13 / 1407.61 | 6 | 38 |
6 | 8 | 0.08 | 450 | 14.25 | 266 | 1706 | 3.83 / 1409.31 | 6 | 52 |
Average= | 6.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 70 | 14.34 | 334 | 335 | 0.34 / 1402.00 | 6 | 15 |
2 | 7 | 1007.44 | 105 | 9.52 | 963 | 963 | 1.30 / 1402.97 | 15 | 28 |
3 | 13 | 800.40 | 36 | 13.36 | 883 | 425 | 1.72 / 1403.39 | 5 | 45 |
4 | 13 | 158.88 | 36 | 14.14 | 405 | 206 | 1.93 / 1403.60 | 6 | 40 |
5 | 13 | 2.32 | 36 | 14.26 | 283 | 145 | 2.07 / 1403.74 | 6 | 47 |
6 | 8 | 0.04 | 450 | 14.26 | 271 | 1739 | 3.81 / 1405.48 | 6 | 55 |
Average= | 6.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 71 | 14.20 | 352 | 355 | 0.35 / 1395.67 | 6 | 15 |
2 | 3 | 1018.56 | 1 | 12.29 | 1016 | 12 | 0.37 / 1395.68 | 5 | 7 |
3 | 7 | 2001.20 | 106 | 6.23 | 1537 | 1015 | 1.38 / 1396.70 | 7 | 5 |
4 | 13 | 1972.76 | 36 | 12.30 | 1672 | 740 | 2.12 / 1397.44 | 5 | 37 |
5 | 13 | 1896.08 | 36 | 12.58 | 1631 | 739 | 2.86 / 1398.18 | 5 | 40 |
6 | 13 | 1695.60 | 36 | 13.02 | 1507 | 706 | 3.57 / 1398.88 | 5 | 46 |
7 | 13 | 1075.92 | 36 | 13.50 | 1084 | 527 | 4.09 / 1399.41 | 5 | 53 |
8 | 13 | 638.52 | 36 | 13.79 | 769 | 382 | 4.48 / 1399.79 | 5 | 53 |
9 | 13 | 47.84 | 36 | 14.24 | 312 | 160 | 4.64 / 1399.95 | 6 | 38 |
10 | 8 | 0.12 | 450 | 14.29 | 267 | 1717 | 6.35 / 1401.67 | 6 | 61 |
Average= | 6.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 71 | 14.23 | 347 | 351 | 0.35 / 1392.02 | 6 | 16 |
2 | 7 | 1008.60 | 105 | 9.27 | 973 | 947 | 1.30 / 1392.96 | 16 | 26 |
3 | 13 | 804.72 | 36 | 13.34 | 884 | 425 | 1.72 / 1393.39 | 5 | 46 |
4 | 13 | 161.24 | 36 | 14.11 | 400 | 203 | 1.93 / 1393.59 | 6 | 40 |
5 | 8 | 0.12 | 450 | 14.23 | 269 | 1723 | 3.65 / 1395.32 | 6 | 54 |
Average= | 6.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 71 | 14.23 | 341 | 345 | 0.34 / 1388.24 | 6 | 17 |
2 | 7 | 1011.88 | 105 | 9.26 | 974 | 947 | 1.29 / 1389.19 | 5 | 27 |
3 | 13 | 907.64 | 36 | 12.97 | 944 | 441 | 1.73 / 1389.63 | 5 | 43 |
4 | 13 | 465.40 | 36 | 13.81 | 630 | 313 | 2.05 / 1389.94 | 5 | 47 |
5 | 8 | 0.16 | 450 | 14.24 | 269 | 1724 | 3.77 / 1391.67 | 6 | 60 |
Average= | 6.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 70 | 14.28 | 339 | 339 | 0.34 / 1384.52 | 6 | 17 |
2 | 7 | 1010.88 | 105 | 9.75 | 973 | 996 | 1.33 / 1385.52 | 17 | 29 |
3 | 13 | 806.04 | 36 | 13.37 | 884 | 425 | 1.76 / 1385.94 | 5 | 46 |
4 | 13 | 264.24 | 36 | 14.03 | 478 | 241 | 2.00 / 1386.19 | 5 | 42 |
5 | 8 | 0.08 | 450 | 14.25 | 267 | 1712 | 3.71 / 1387.90 | 6 | 51 |
Average= | 6.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 71 | 14.23 | 343 | 347 | 0.35 / 1378.22 | 6 | 17 |
2 | 7 | 2010.60 | 105 | 7.09 | 1579 | 1175 | 1.52 / 1379.39 | 5 | 8 |
3 | 13 | 1970.12 | 36 | 12.55 | 1680 | 759 | 2.28 / 1380.15 | 5 | 39 |
4 | 13 | 1883.44 | 36 | 12.81 | 1624 | 749 | 3.03 / 1380.90 | 5 | 43 |
5 | 13 | 1475.16 | 36 | 13.29 | 1368 | 655 | 3.68 / 1381.55 | 5 | 50 |
6 | 13 | 1050.00 | 36 | 13.54 | 1073 | 523 | 4.21 / 1382.08 | 5 | 54 |
7 | 13 | 590.56 | 36 | 13.85 | 731 | 364 | 4.57 / 1382.44 | 5 | 53 |
8 | 8 | 0.04 | 450 | 14.28 | 271 | 1741 | 6.31 / 1384.18 | 6 | 63 |
Average= | 6.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 71 | 14.23 | 348 | 352 | 0.35 / 1374.49 | 6 | 18 |
2 | 7 | 1011.24 | 105 | 9.88 | 988 | 1025 | 1.38 / 1375.51 | 18 | 29 |
3 | 13 | 712.40 | 36 | 13.52 | 820 | 399 | 1.78 / 1375.91 | 5 | 47 |
4 | 13 | 274.60 | 36 | 14.00 | 486 | 245 | 2.02 / 1376.15 | 5 | 43 |
5 | 8 | 0.20 | 450 | 14.23 | 268 | 1716 | 3.74 / 1377.87 | 6 | 56 |
Average= | 6.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 70 | 14.21 | 344 | 342 | 0.34 / 1370.75 | 6 | 18 |
2 | 3 | 1010.44 | 1 | 12.48 | 1031 | 13 | 0.36 / 1370.76 | 5 | 5 |
3 | 7 | 1022.40 | 105 | 10.04 | 987 | 1040 | 1.40 / 1371.80 | 5 | 30 |
4 | 13 | 809.20 | 36 | 13.43 | 885 | 428 | 1.82 / 1372.23 | 5 | 46 |
5 | 13 | 82.56 | 36 | 14.22 | 334 | 171 | 1.99 / 1372.40 | 6 | 38 |
6 | 8 | 0.12 | 450 | 14.24 | 270 | 1730 | 3.72 / 1374.13 | 6 | 62 |
Average= | 6.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 70 | 14.24 | 340 | 339 | 0.34 / 1367.08 | 6 | 17 |
2 | 7 | 1009.76 | 105 | 10.58 | 970 | 1078 | 1.42 / 1368.16 | 5 | 31 |
3 | 13 | 696.48 | 36 | 13.67 | 808 | 398 | 1.81 / 1368.56 | 5 | 48 |
4 | 13 | 16.68 | 36 | 14.24 | 286 | 147 | 1.96 / 1368.71 | 6 | 37 |
5 | 8 | 0.12 | 450 | 14.23 | 266 | 1703 | 3.66 / 1370.41 | 6 | 69 |
Average= | 6.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 70 | 14.20 | 351 | 349 | 0.35 / 1360.95 | 6 | 17 |
2 | 3 | 1015.96 | 1 | 12.77 | 1021 | 13 | 0.36 / 1360.96 | 5 | 7 |
3 | 7 | 2011.76 | 106 | 9.74 | 1655 | 1709 | 2.07 / 1362.67 | 7 | 25 |
4 | 13 | 1925.64 | 36 | 12.86 | 1649 | 763 | 2.83 / 1363.43 | 5 | 43 |
5 | 13 | 1732.00 | 36 | 13.18 | 1534 | 728 | 3.56 / 1364.16 | 5 | 48 |
6 | 13 | 1075.00 | 36 | 13.54 | 1098 | 535 | 4.10 / 1364.70 | 5 | 54 |
7 | 13 | 438.44 | 36 | 13.95 | 612 | 307 | 4.40 / 1365.00 | 5 | 49 |
8 | 8 | 0.00 | 450 | 14.27 | 271 | 1740 | 6.14 / 1366.75 | 6 | 53 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 70 | 14.20 | 344 | 342 | 0.34 / 1357.26 | 6 | 18 |
2 | 7 | 1011.28 | 106 | 12.84 | 1000 | 1361 | 1.70 / 1358.62 | 18 | 43 |
3 | 13 | 253.20 | 36 | 14.08 | 474 | 240 | 1.94 / 1358.86 | 5 | 41 |
4 | 8 | 0.12 | 450 | 14.23 | 271 | 1735 | 3.68 / 1360.60 | 6 | 62 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 70 | 14.18 | 341 | 338 | 0.34 / 1353.62 | 6 | 18 |
2 | 7 | 1004.88 | 105 | 12.69 | 994 | 1324 | 1.66 / 1354.94 | 18 | 41 |
3 | 13 | 332.48 | 36 | 14.02 | 531 | 268 | 1.93 / 1355.21 | 5 | 43 |
4 | 8 | 0.12 | 450 | 14.24 | 267 | 1711 | 3.64 / 1356.92 | 6 | 61 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 70 | 14.21 | 350 | 348 | 0.35 / 1349.91 | 6 | 18 |
2 | 7 | 1022.68 | 105 | 12.93 | 1019 | 1383 | 1.73 / 1351.29 | 5 | 41 |
3 | 13 | 346.60 | 36 | 14.00 | 542 | 273 | 2.00 / 1351.56 | 5 | 44 |
4 | 8 | 0.12 | 450 | 14.24 | 268 | 1717 | 3.72 / 1353.28 | 6 | 57 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 67 | 14.19 | 352 | 335 | 0.33 / 1343.62 | 6 | 17 |
2 | 3 | 1067.48 | 3 | 12.99 | 1075 | 42 | 0.38 / 1343.66 | 5 | 29 |
3 | 7 | 2007.00 | 106 | 9.56 | 1641 | 1663 | 2.04 / 1345.32 | 29 | 25 |
4 | 13 | 1922.88 | 36 | 12.87 | 1654 | 766 | 2.81 / 1346.09 | 5 | 43 |
5 | 13 | 1722.32 | 36 | 13.11 | 1530 | 722 | 3.53 / 1346.81 | 5 | 47 |
6 | 13 | 1172.36 | 36 | 13.46 | 1156 | 560 | 4.09 / 1347.37 | 5 | 54 |
7 | 13 | 835.36 | 36 | 13.64 | 918 | 451 | 4.54 / 1347.82 | 5 | 55 |
8 | 8 | 0.08 | 450 | 14.27 | 270 | 1734 | 6.27 / 1349.56 | 6 | 59 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 70 | 14.20 | 342 | 340 | 0.34 / 1339.89 | 6 | 18 |
2 | 7 | 993.32 | 105 | 12.80 | 988 | 1328 | 1.67 / 1341.21 | 18 | 42 |
3 | 13 | 533.48 | 36 | 13.83 | 690 | 344 | 2.01 / 1341.56 | 5 | 47 |
4 | 8 | 0.16 | 450 | 14.22 | 270 | 1728 | 3.74 / 1343.29 | 6 | 59 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 70 | 14.19 | 341 | 339 | 0.34 / 1336.21 | 6 | 18 |
2 | 3 | 1015.28 | 1 | 12.56 | 1016 | 13 | 0.35 / 1336.22 | 5 | 6 |
3 | 7 | 999.40 | 105 | 12.58 | 1003 | 1325 | 1.68 / 1337.55 | 6 | 41 |
4 | 13 | 352.44 | 36 | 13.97 | 549 | 276 | 1.95 / 1337.82 | 5 | 44 |
5 | 8 | 0.12 | 450 | 14.22 | 269 | 1721 | 3.67 / 1339.55 | 6 | 55 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 70 | 14.17 | 345 | 342 | 0.34 / 1332.52 | 6 | 17 |
2 | 7 | 985.16 | 105 | 12.82 | 987 | 1329 | 1.67 / 1333.85 | 17 | 41 |
3 | 13 | 411.80 | 36 | 13.92 | 588 | 295 | 1.97 / 1334.14 | 5 | 46 |
4 | 8 | 0.08 | 450 | 14.22 | 270 | 1728 | 3.69 / 1335.87 | 6 | 60 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 70 | 14.23 | 352 | 351 | 0.35 / 1326.04 | 6 | 18 |
2 | 3 | 955.84 | -1 | 14.23 | 352 | 0 | 0.00 / 1326.04 | 6 | 18 |
3 | 7 | 2004.56 | 105 | 6.32 | 1581 | 1049 | 1.40 / 1327.09 | 18 | 5 |
4 | 13 | 1974.44 | 36 | 12.41 | 1679 | 750 | 2.15 / 1327.84 | 5 | 39 |
5 | 13 | 1899.60 | 36 | 12.69 | 1635 | 747 | 2.90 / 1328.58 | 5 | 42 |
6 | 13 | 1803.24 | 36 | 12.89 | 1574 | 730 | 3.63 / 1329.31 | 5 | 45 |
7 | 13 | 1251.56 | 36 | 13.34 | 1207 | 580 | 4.21 / 1329.89 | 5 | 53 |
8 | 13 | 607.96 | 36 | 13.74 | 748 | 370 | 4.58 / 1330.26 | 5 | 52 |
9 | 13 | 79.04 | 36 | 14.19 | 340 | 174 | 4.75 / 1330.44 | 6 | 40 |
10 | 8 | 0.08 | 450 | 14.24 | 272 | 1743 | 6.49 / 1332.18 | 6 | 55 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 70 | 14.17 | 348 | 345 | 0.35 / 1319.53 | 6 | 19 |
2 | 7 | 2002.96 | 106 | 6.28 | 1581 | 1052 | 1.40 / 1320.58 | 19 | 5 |
3 | 13 | 1977.08 | 36 | 12.40 | 1682 | 751 | 2.15 / 1321.33 | 5 | 40 |
4 | 13 | 1905.96 | 36 | 12.68 | 1640 | 749 | 2.90 / 1322.08 | 5 | 43 |
5 | 13 | 1808.08 | 36 | 12.88 | 1580 | 733 | 3.63 / 1322.81 | 5 | 45 |
6 | 13 | 1142.04 | 36 | 13.41 | 1134 | 547 | 4.18 / 1323.36 | 5 | 53 |
7 | 13 | 712.72 | 36 | 13.69 | 823 | 406 | 4.58 / 1323.76 | 5 | 55 |
8 | 13 | 72.40 | 36 | 14.18 | 336 | 172 | 4.75 / 1323.94 | 6 | 41 |
9 | 8 | 0.00 | 450 | 14.24 | 273 | 1749 | 6.50 / 1325.69 | 6 | 64 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 70 | 14.17 | 344 | 341 | 0.34 / 1312.93 | 6 | 18 |
2 | 7 | 2003.76 | 105 | 6.25 | 1578 | 1036 | 1.38 / 1313.97 | 18 | 5 |
3 | 13 | 1967.92 | 36 | 12.39 | 1679 | 749 | 2.13 / 1314.71 | 5 | 40 |
4 | 13 | 1891.20 | 36 | 12.67 | 1629 | 743 | 2.87 / 1315.46 | 5 | 42 |
5 | 13 | 1794.52 | 36 | 12.88 | 1570 | 728 | 3.60 / 1316.19 | 5 | 46 |
6 | 13 | 1236.88 | 36 | 13.35 | 1199 | 576 | 4.17 / 1316.76 | 5 | 54 |
7 | 13 | 909.44 | 36 | 13.55 | 966 | 471 | 4.64 / 1317.23 | 5 | 56 |
8 | 13 | 98.12 | 36 | 14.15 | 356 | 181 | 4.83 / 1317.41 | 6 | 42 |
9 | 8 | 0.12 | 450 | 14.23 | 276 | 1767 | 6.59 / 1319.18 | 6 | 58 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 70 | 14.16 | 344 | 341 | 0.34 / 1306.56 | 6 | 18 |
2 | 7 | 2010.00 | 105 | 6.31 | 1571 | 1041 | 1.38 / 1307.60 | 18 | 5 |
3 | 13 | 1966.76 | 36 | 12.40 | 1675 | 748 | 2.13 / 1308.35 | 5 | 39 |
4 | 13 | 1885.88 | 36 | 12.70 | 1623 | 742 | 2.87 / 1309.09 | 5 | 44 |
5 | 13 | 1591.04 | 36 | 13.11 | 1442 | 681 | 3.55 / 1309.77 | 5 | 49 |
6 | 13 | 1085.64 | 36 | 13.44 | 1094 | 529 | 4.08 / 1310.30 | 5 | 54 |
7 | 13 | 660.68 | 36 | 13.72 | 775 | 383 | 4.46 / 1310.68 | 5 | 55 |
8 | 13 | 96.52 | 36 | 14.16 | 350 | 178 | 4.64 / 1310.86 | 6 | 42 |
9 | 8 | 0.16 | 450 | 14.24 | 270 | 1730 | 6.37 / 1312.59 | 6 | 59 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 70 | 14.17 | 345 | 342 | 0.34 / 1300.06 | 6 | 18 |
2 | 7 | 2006.88 | 105 | 6.45 | 1579 | 1069 | 1.41 / 1301.13 | 18 | 5 |
3 | 13 | 1965.76 | 36 | 12.45 | 1669 | 748 | 2.16 / 1301.87 | 5 | 40 |
4 | 13 | 1888.20 | 36 | 12.73 | 1623 | 744 | 2.90 / 1302.62 | 5 | 43 |
5 | 13 | 1789.88 | 36 | 12.91 | 1565 | 727 | 3.63 / 1303.35 | 5 | 47 |
6 | 13 | 1223.32 | 36 | 13.35 | 1185 | 570 | 4.20 / 1303.92 | 5 | 54 |
7 | 13 | 664.76 | 36 | 13.69 | 784 | 386 | 4.59 / 1304.30 | 5 | 55 |
8 | 13 | 107.76 | 36 | 14.13 | 362 | 184 | 4.77 / 1304.49 | 5 | 43 |
9 | 8 | -0.08 | 450 | 14.24 | 270 | 1730 | 6.50 / 1306.22 | 6 | 62 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 69 | 14.17 | 342 | 334 | 0.33 / 1293.90 | 6 | 16 |
2 | 7 | 2007.96 | 105 | 6.56 | 1560 | 1075 | 1.41 / 1294.97 | 5 | 6 |
3 | 13 | 1978.40 | 36 | 12.47 | 1673 | 751 | 2.16 / 1295.72 | 5 | 40 |
4 | 13 | 1898.28 | 36 | 12.72 | 1633 | 748 | 2.91 / 1296.47 | 5 | 43 |
5 | 13 | 1495.92 | 36 | 13.19 | 1372 | 651 | 3.56 / 1297.12 | 5 | 50 |
6 | 13 | 1084.36 | 36 | 13.44 | 1085 | 525 | 4.08 / 1297.65 | 5 | 55 |
7 | 13 | 545.28 | 36 | 13.79 | 694 | 345 | 4.43 / 1297.99 | 5 | 53 |
8 | 8 | 0.16 | 450 | 14.25 | 269 | 1725 | 6.15 / 1299.72 | 6 | 59 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 69 | 14.16 | 344 | 336 | 0.34 / 1287.36 | 6 | 17 |
2 | 7 | 2003.08 | 105 | 6.59 | 1571 | 1087 | 1.42 / 1288.45 | 17 | 6 |
3 | 13 | 1967.44 | 36 | 12.46 | 1672 | 750 | 2.17 / 1289.20 | 5 | 40 |
4 | 13 | 1886.80 | 36 | 12.74 | 1624 | 745 | 2.92 / 1289.95 | 5 | 44 |
5 | 13 | 1582.24 | 36 | 13.10 | 1438 | 678 | 3.60 / 1290.62 | 5 | 50 |
6 | 13 | 1044.36 | 36 | 13.44 | 1073 | 519 | 4.12 / 1291.14 | 5 | 54 |
7 | 13 | 625.96 | 36 | 13.71 | 761 | 376 | 4.49 / 1291.52 | 5 | 53 |
8 | 13 | 82.60 | 36 | 14.15 | 341 | 174 | 4.66 / 1291.69 | 6 | 43 |
9 | 13 | 20.92 | 36 | 14.23 | 294 | 151 | 4.82 / 1291.84 | 6 | 43 |
10 | 8 | -0.08 | 450 | 14.25 | 268 | 1719 | 6.53 / 1293.56 | 6 | 66 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 69 | 14.15 | 351 | 343 | 0.34 / 1281.19 | 6 | 16 |
2 | 3 | 1012.56 | 1 | 12.49 | 1015 | 13 | 0.36 / 1281.21 | 5 | 5 |
3 | 7 | 2002.76 | 105 | 6.66 | 1580 | 1105 | 1.46 / 1282.31 | 5 | 6 |
4 | 13 | 1963.56 | 36 | 12.53 | 1674 | 755 | 2.22 / 1283.07 | 5 | 41 |
5 | 13 | 1885.12 | 36 | 12.78 | 1624 | 747 | 2.96 / 1283.81 | 5 | 43 |
6 | 13 | 1588.44 | 36 | 13.11 | 1442 | 681 | 3.64 / 1284.49 | 5 | 49 |
7 | 13 | 970.36 | 36 | 13.50 | 1009 | 490 | 4.13 / 1284.98 | 5 | 56 |
8 | 13 | 449.68 | 36 | 13.84 | 628 | 313 | 4.45 / 1285.30 | 5 | 50 |
9 | 8 | 0.20 | 450 | 14.25 | 270 | 1731 | 6.18 / 1287.03 | 6 | 52 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 67 | 14.14 | 349 | 331 | 0.33 / 1274.68 | 6 | 16 |
2 | 3 | 1038.32 | 2 | 12.70 | 1043 | 26 | 0.36 / 1274.71 | 5 | 19 |
3 | 7 | 2002.52 | 105 | 6.67 | 1584 | 1109 | 1.47 / 1275.82 | 19 | 7 |
4 | 13 | 1960.36 | 36 | 12.55 | 1674 | 756 | 2.22 / 1276.58 | 5 | 41 |
5 | 13 | 1882.56 | 36 | 12.79 | 1627 | 749 | 2.97 / 1277.32 | 5 | 44 |
6 | 13 | 1789.84 | 36 | 12.94 | 1571 | 732 | 3.70 / 1278.06 | 5 | 47 |
7 | 13 | 1227.36 | 36 | 13.33 | 1196 | 574 | 4.28 / 1278.63 | 5 | 55 |
8 | 13 | 545.36 | 36 | 13.78 | 701 | 348 | 4.63 / 1278.98 | 5 | 52 |
9 | 13 | 10.00 | 36 | 14.23 | 284 | 145 | 4.77 / 1279.12 | 6 | 38 |
10 | 8 | 0.16 | 450 | 14.26 | 269 | 1726 | 6.50 / 1280.85 | 6 | 57 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 70 | 14.16 | 335 | 332 | 0.33 / 1268.21 | 6 | 17 |
2 | 3 | 933.32 | -1 | 14.16 | 335 | 0 | 0.00 / 1268.21 | 6 | 17 |
3 | 7 | 2012.28 | 105 | 6.59 | 1594 | 1103 | 1.44 / 1269.32 | 17 | 6 |
4 | 13 | 1983.80 | 36 | 12.53 | 1686 | 761 | 2.20 / 1270.08 | 5 | 41 |
5 | 13 | 1909.48 | 36 | 12.77 | 1645 | 756 | 2.95 / 1270.83 | 5 | 44 |
6 | 13 | 1505.04 | 36 | 13.17 | 1383 | 656 | 3.61 / 1271.49 | 5 | 52 |
7 | 13 | 1297.92 | 36 | 13.30 | 1244 | 596 | 4.20 / 1272.09 | 5 | 54 |
8 | 13 | 613.16 | 36 | 13.72 | 751 | 371 | 4.57 / 1272.46 | 5 | 54 |
9 | 13 | 41.84 | 36 | 14.19 | 308 | 157 | 4.73 / 1272.61 | 6 | 40 |
10 | 8 | 0.04 | 450 | 14.26 | 271 | 1739 | 6.47 / 1274.35 | 6 | 64 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 70 | 14.18 | 345 | 342 | 0.34 / 1261.74 | 6 | 16 |
2 | 7 | 2002.52 | 105 | 6.69 | 1584 | 1113 | 1.46 / 1262.85 | 16 | 7 |
3 | 13 | 1948.60 | 36 | 12.53 | 1668 | 752 | 2.21 / 1263.61 | 5 | 42 |
4 | 13 | 1870.80 | 36 | 12.80 | 1619 | 746 | 2.95 / 1264.35 | 5 | 45 |
5 | 13 | 1784.44 | 36 | 12.94 | 1569 | 731 | 3.68 / 1265.08 | 5 | 47 |
6 | 13 | 1109.48 | 36 | 13.41 | 1116 | 539 | 4.22 / 1265.62 | 5 | 55 |
7 | 13 | 556.92 | 36 | 13.77 | 708 | 351 | 4.57 / 1265.97 | 5 | 54 |
8 | 13 | 58.80 | 36 | 14.17 | 323 | 165 | 4.74 / 1266.14 | 6 | 41 |
9 | 8 | 0.16 | 450 | 14.26 | 272 | 1745 | 6.48 / 1267.88 | 6 | 60 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 70 | 14.19 | 334 | 332 | 0.33 / 1255.28 | 6 | 15 |
2 | 7 | 2011.52 | 105 | 6.83 | 1593 | 1142 | 1.47 / 1256.42 | 15 | 8 |
3 | 13 | 1968.48 | 36 | 12.53 | 1679 | 757 | 2.23 / 1257.18 | 5 | 41 |
4 | 13 | 1886.96 | 36 | 12.79 | 1626 | 749 | 2.98 / 1257.93 | 5 | 44 |
5 | 13 | 1691.32 | 36 | 13.05 | 1504 | 707 | 3.69 / 1258.63 | 5 | 49 |
6 | 13 | 1039.04 | 36 | 13.45 | 1058 | 512 | 4.20 / 1259.14 | 5 | 55 |
7 | 13 | 608.36 | 36 | 13.73 | 739 | 365 | 4.56 / 1259.51 | 5 | 54 |
8 | 13 | 67.08 | 36 | 14.17 | 330 | 168 | 4.73 / 1259.68 | 6 | 42 |
9 | 8 | 0.08 | 450 | 14.26 | 268 | 1720 | 6.45 / 1261.40 | 6 | 65 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 70 | 14.19 | 334 | 332 | 0.33 / 1248.86 | 6 | 17 |
2 | 7 | 2009.32 | 105 | 6.80 | 1585 | 1132 | 1.46 / 1250.00 | 17 | 7 |
3 | 13 | 1958.88 | 36 | 12.56 | 1670 | 755 | 2.22 / 1250.75 | 5 | 42 |
4 | 13 | 1871.80 | 36 | 12.81 | 1613 | 744 | 2.96 / 1251.49 | 5 | 45 |
5 | 13 | 1675.48 | 36 | 13.04 | 1504 | 706 | 3.67 / 1252.20 | 5 | 50 |
6 | 13 | 1031.44 | 36 | 13.46 | 1060 | 514 | 4.18 / 1252.71 | 5 | 55 |
7 | 13 | 497.48 | 36 | 13.81 | 664 | 330 | 4.51 / 1253.04 | 5 | 52 |
8 | 13 | 77.88 | 36 | 14.16 | 343 | 175 | 4.69 / 1253.22 | 6 | 42 |
9 | 8 | 0.20 | 450 | 14.26 | 269 | 1726 | 6.41 / 1254.95 | 7 | 65 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 70 | 14.18 | 337 | 335 | 0.33 / 1242.32 | 6 | 15 |
2 | 7 | 2010.48 | 105 | 6.83 | 1588 | 1139 | 1.47 / 1243.46 | 15 | 7 |
3 | 13 | 1966.52 | 36 | 12.61 | 1672 | 759 | 2.23 / 1244.22 | 5 | 41 |
4 | 13 | 1885.60 | 36 | 12.81 | 1626 | 750 | 2.98 / 1244.97 | 5 | 45 |
5 | 13 | 1691.64 | 36 | 13.07 | 1499 | 705 | 3.69 / 1245.67 | 5 | 50 |
6 | 13 | 1242.48 | 36 | 13.34 | 1198 | 575 | 4.26 / 1246.25 | 5 | 55 |
7 | 13 | 693.44 | 36 | 13.67 | 816 | 402 | 4.66 / 1246.65 | 5 | 56 |
8 | 13 | 55.16 | 36 | 14.18 | 321 | 164 | 4.83 / 1246.81 | 6 | 42 |
9 | 8 | 0.16 | 450 | 14.27 | 268 | 1721 | 6.55 / 1248.53 | 6 | 61 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 70 | 14.21 | 335 | 333 | 0.33 / 1235.91 | 6 | 16 |
2 | 7 | 2012.32 | 105 | 7.02 | 1581 | 1165 | 1.50 / 1237.07 | 16 | 8 |
3 | 13 | 1980.68 | 36 | 12.60 | 1681 | 763 | 2.26 / 1237.83 | 5 | 42 |
4 | 13 | 1906.36 | 36 | 12.82 | 1638 | 756 | 3.02 / 1238.59 | 5 | 44 |
5 | 13 | 1487.64 | 36 | 13.19 | 1374 | 652 | 3.67 / 1239.24 | 5 | 51 |
6 | 13 | 1063.64 | 36 | 13.42 | 1078 | 521 | 4.19 / 1239.76 | 5 | 55 |
7 | 13 | 518.80 | 36 | 13.78 | 677 | 336 | 4.53 / 1240.10 | 5 | 52 |
8 | 13 | 42.96 | 36 | 14.21 | 309 | 158 | 4.68 / 1240.26 | 6 | 41 |
9 | 8 | 0.08 | 450 | 14.26 | 269 | 1726 | 6.41 / 1241.98 | 6 | 62 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 70 | 14.22 | 339 | 337 | 0.34 / 1229.53 | 6 | 15 |
2 | 7 | 2008.32 | 105 | 7.09 | 1585 | 1180 | 1.52 / 1230.71 | 15 | 9 |
3 | 13 | 1962.16 | 36 | 12.62 | 1674 | 761 | 2.28 / 1231.47 | 5 | 43 |
4 | 13 | 1891.12 | 36 | 12.82 | 1634 | 754 | 3.03 / 1232.23 | 5 | 45 |
5 | 13 | 1366.48 | 36 | 13.25 | 1291 | 616 | 3.65 / 1232.84 | 5 | 52 |
6 | 13 | 1060.00 | 36 | 13.44 | 1078 | 522 | 4.17 / 1233.37 | 5 | 55 |
7 | 13 | 496.36 | 36 | 13.81 | 661 | 329 | 4.50 / 1233.69 | 5 | 52 |
8 | 13 | 38.08 | 36 | 14.21 | 308 | 158 | 4.66 / 1233.85 | 6 | 42 |
9 | 8 | 0.08 | 450 | 14.27 | 268 | 1721 | 6.38 / 1235.57 | 6 | 58 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 70 | 14.24 | 332 | 331 | 0.33 / 1223.09 | 6 | 16 |
2 | 7 | 2009.04 | 105 | 7.20 | 1591 | 1203 | 1.53 / 1224.29 | 5 | 10 |
3 | 13 | 1957.36 | 36 | 12.66 | 1666 | 759 | 2.29 / 1225.05 | 5 | 42 |
4 | 13 | 1866.72 | 36 | 12.87 | 1607 | 745 | 3.04 / 1225.80 | 5 | 46 |
5 | 13 | 1659.24 | 36 | 13.09 | 1483 | 699 | 3.74 / 1226.50 | 5 | 50 |
6 | 13 | 1012.56 | 36 | 13.46 | 1038 | 503 | 4.24 / 1227.00 | 5 | 55 |
7 | 13 | 459.92 | 36 | 13.83 | 628 | 313 | 4.55 / 1227.31 | 5 | 51 |
8 | 13 | 55.60 | 36 | 14.17 | 321 | 164 | 4.72 / 1227.48 | 6 | 42 |
9 | 8 | 0.04 | 450 | 14.27 | 268 | 1721 | 6.44 / 1229.20 | 6 | 65 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 70 | 14.25 | 337 | 336 | 0.34 / 1216.70 | 6 | 15 |
2 | 7 | 2012.12 | 105 | 7.22 | 1604 | 1216 | 1.55 / 1217.92 | 15 | 10 |
3 | 13 | 1960.04 | 36 | 12.65 | 1670 | 761 | 2.31 / 1218.68 | 5 | 42 |
4 | 13 | 1877.28 | 36 | 12.86 | 1618 | 749 | 3.06 / 1219.43 | 5 | 45 |
5 | 13 | 1453.36 | 36 | 13.19 | 1348 | 640 | 3.70 / 1220.07 | 5 | 52 |
6 | 13 | 1134.04 | 36 | 13.39 | 1133 | 546 | 4.25 / 1220.61 | 5 | 55 |
7 | 13 | 363.44 | 36 | 13.90 | 564 | 282 | 4.53 / 1220.90 | 5 | 48 |
8 | 13 | 34.72 | 36 | 14.21 | 301 | 154 | 4.68 / 1221.05 | 6 | 41 |
9 | 8 | 0.20 | 450 | 14.28 | 266 | 1709 | 6.39 / 1222.76 | 6 | 64 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 70 | 14.26 | 337 | 336 | 0.34 / 1210.41 | 6 | 15 |
2 | 7 | 2010.96 | 105 | 7.33 | 1602 | 1233 | 1.57 / 1211.64 | 15 | 11 |
3 | 13 | 1957.56 | 36 | 12.64 | 1671 | 760 | 2.33 / 1212.40 | 5 | 42 |
4 | 13 | 1876.04 | 36 | 12.87 | 1620 | 751 | 3.08 / 1213.15 | 5 | 46 |
5 | 13 | 1361.48 | 36 | 13.25 | 1287 | 614 | 3.69 / 1213.77 | 5 | 52 |
6 | 13 | 837.92 | 36 | 13.55 | 921 | 449 | 4.14 / 1214.22 | 5 | 55 |
7 | 13 | 317.56 | 36 | 13.95 | 526 | 264 | 4.41 / 1214.48 | 5 | 47 |
8 | 13 | 47.40 | 36 | 14.19 | 312 | 159 | 4.57 / 1214.64 | 6 | 41 |
9 | 8 | 0.04 | 450 | 14.27 | 269 | 1727 | 6.29 / 1216.37 | 6 | 63 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 70 | 14.21 | 337 | 335 | 0.34 / 1204.03 | 6 | 15 |
2 | 7 | 2012.64 | 106 | 7.38 | 1604 | 1255 | 1.59 / 1205.29 | 15 | 12 |
3 | 13 | 1958.92 | 36 | 12.67 | 1669 | 761 | 2.35 / 1206.05 | 5 | 43 |
4 | 13 | 1874.92 | 36 | 12.87 | 1621 | 751 | 3.10 / 1206.80 | 5 | 45 |
5 | 13 | 1454.80 | 36 | 13.20 | 1348 | 641 | 3.74 / 1207.44 | 5 | 53 |
6 | 13 | 932.24 | 36 | 13.50 | 985 | 479 | 4.22 / 1207.92 | 5 | 56 |
7 | 13 | 382.76 | 36 | 13.88 | 578 | 289 | 4.51 / 1208.21 | 5 | 49 |
8 | 13 | 36.72 | 36 | 14.21 | 305 | 156 | 4.67 / 1208.36 | 6 | 41 |
9 | 8 | 0.08 | 450 | 14.28 | 266 | 1709 | 6.38 / 1210.07 | 6 | 59 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 70 | 14.16 | 341 | 338 | 0.34 / 1197.61 | 6 | 15 |
2 | 7 | 2005.16 | 106 | 7.42 | 1608 | 1265 | 1.60 / 1198.87 | 15 | 13 |
3 | 13 | 1953.84 | 36 | 12.70 | 1673 | 765 | 2.37 / 1199.64 | 5 | 42 |
4 | 13 | 1866.36 | 36 | 12.90 | 1608 | 747 | 3.11 / 1200.38 | 5 | 46 |
5 | 13 | 1452.20 | 36 | 13.21 | 1350 | 642 | 3.76 / 1201.03 | 5 | 52 |
6 | 13 | 930.88 | 36 | 13.51 | 987 | 480 | 4.24 / 1201.51 | 5 | 56 |
7 | 13 | 405.36 | 36 | 13.88 | 595 | 297 | 4.53 / 1201.80 | 5 | 50 |
8 | 13 | 40.76 | 36 | 14.20 | 311 | 159 | 4.69 / 1201.96 | 6 | 42 |
9 | 8 | 0.08 | 450 | 14.27 | 270 | 1734 | 6.43 / 1203.70 | 6 | 60 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 70 | 14.22 | 332 | 330 | 0.33 / 1191.03 | 6 | 15 |
2 | 7 | 2011.80 | 105 | 7.62 | 1616 | 1293 | 1.62 / 1192.33 | 15 | 15 |
3 | 13 | 1966.88 | 36 | 12.70 | 1673 | 765 | 2.39 / 1193.09 | 5 | 44 |
4 | 13 | 1887.28 | 36 | 12.88 | 1624 | 753 | 3.14 / 1193.84 | 5 | 46 |
5 | 13 | 1345.80 | 36 | 13.25 | 1278 | 610 | 3.75 / 1194.45 | 5 | 54 |
6 | 13 | 1138.32 | 36 | 13.37 | 1136 | 547 | 4.30 / 1195.00 | 5 | 56 |
7 | 13 | 669.12 | 36 | 13.67 | 801 | 394 | 4.69 / 1195.39 | 5 | 56 |
8 | 13 | 42.48 | 36 | 14.21 | 313 | 160 | 4.85 / 1195.55 | 6 | 42 |
9 | 8 | 0.08 | 450 | 14.27 | 267 | 1715 | 6.57 / 1197.27 | 6 | 64 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 70 | 14.16 | 341 | 338 | 0.34 / 1184.82 | 6 | 14 |
2 | 7 | 2007.20 | 105 | 7.76 | 1603 | 1306 | 1.64 / 1186.13 | 14 | 16 |
3 | 13 | 1932.40 | 36 | 12.75 | 1651 | 758 | 2.40 / 1186.89 | 5 | 45 |
4 | 13 | 1746.64 | 36 | 13.01 | 1542 | 722 | 3.12 / 1187.61 | 5 | 49 |
5 | 13 | 1234.72 | 36 | 13.33 | 1194 | 573 | 3.70 / 1188.18 | 5 | 54 |
6 | 13 | 916.36 | 36 | 13.51 | 976 | 475 | 4.17 / 1188.66 | 5 | 56 |
7 | 13 | 86.60 | 36 | 14.18 | 343 | 175 | 4.35 / 1188.83 | 6 | 42 |
8 | 13 | 22.24 | 36 | 14.27 | 297 | 153 | 4.50 / 1188.99 | 6 | 41 |
9 | 8 | -0.04 | 450 | 14.29 | 267 | 1717 | 6.22 / 1190.70 | 6 | 66 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 69 | 14.20 | 335 | 328 | 0.33 / 1178.19 | 6 | 14 |
2 | 3 | 1017.60 | 1 | 12.85 | 1023 | 13 | 0.34 / 1178.20 | 5 | 7 |
3 | 7 | 2009.32 | 105 | 7.89 | 1605 | 1330 | 1.67 / 1179.53 | 7 | 16 |
4 | 13 | 1945.44 | 36 | 12.74 | 1657 | 760 | 2.43 / 1180.29 | 5 | 43 |
5 | 13 | 1856.80 | 36 | 12.89 | 1603 | 744 | 3.17 / 1181.03 | 5 | 45 |
6 | 13 | 1554.24 | 36 | 13.15 | 1414 | 669 | 3.84 / 1181.70 | 5 | 52 |
7 | 13 | 1101.28 | 36 | 13.41 | 1108 | 535 | 4.38 / 1182.24 | 5 | 55 |
8 | 13 | 312.24 | 36 | 13.96 | 521 | 262 | 4.64 / 1182.50 | 5 | 47 |
9 | 13 | 25.32 | 36 | 14.24 | 297 | 152 | 4.79 / 1182.65 | 6 | 40 |
10 | 13 | 12.60 | 36 | 14.26 | 282 | 145 | 4.94 / 1182.80 | 6 | 43 |
11 | 8 | 0.04 | 450 | 14.29 | 263 | 1691 | 6.63 / 1184.49 | 6 | 63 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 69 | 14.21 | 335 | 328 | 0.33 / 1171.78 | 6 | 15 |
2 | 7 | 2003.48 | 105 | 8.02 | 1608 | 1354 | 1.68 / 1173.14 | 15 | 18 |
3 | 13 | 1946.72 | 36 | 12.75 | 1658 | 761 | 2.44 / 1173.90 | 5 | 42 |
4 | 13 | 1853.28 | 36 | 12.91 | 1601 | 744 | 3.19 / 1174.64 | 5 | 46 |
5 | 13 | 1305.44 | 36 | 13.30 | 1239 | 593 | 3.78 / 1175.24 | 5 | 53 |
6 | 13 | 791.76 | 36 | 13.58 | 879 | 430 | 4.21 / 1175.67 | 5 | 54 |
7 | 13 | 154.44 | 36 | 14.11 | 394 | 200 | 4.41 / 1175.87 | 5 | 41 |
8 | 13 | 33.80 | 36 | 14.23 | 299 | 153 | 4.56 / 1176.02 | 6 | 41 |
9 | 13 | 18.56 | 36 | 14.26 | 286 | 147 | 4.71 / 1176.17 | 6 | 42 |
10 | 8 | 0.08 | 450 | 14.29 | 263 | 1691 | 6.40 / 1177.86 | 6 | 65 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 69 | 14.19 | 340 | 333 | 0.33 / 1165.34 | 6 | 15 |
2 | 7 | 2011.08 | 105 | 7.91 | 1616 | 1342 | 1.68 / 1166.68 | 5 | 17 |
3 | 13 | 1945.32 | 36 | 12.77 | 1659 | 763 | 2.44 / 1167.44 | 5 | 42 |
4 | 13 | 1847.88 | 36 | 12.94 | 1600 | 745 | 3.18 / 1168.19 | 5 | 46 |
5 | 13 | 1652.20 | 36 | 13.11 | 1476 | 697 | 3.88 / 1168.88 | 5 | 49 |
6 | 13 | 885.72 | 36 | 13.54 | 945 | 461 | 4.34 / 1169.34 | 5 | 54 |
7 | 13 | 335.92 | 36 | 13.94 | 538 | 270 | 4.61 / 1169.61 | 5 | 46 |
8 | 13 | 11.12 | 36 | 14.24 | 284 | 146 | 4.76 / 1169.76 | 6 | 39 |
9 | 8 | 0.04 | 450 | 14.28 | 264 | 1696 | 6.45 / 1171.46 | 6 | 58 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 69 | 14.20 | 332 | 325 | 0.33 / 1158.87 | 6 | 17 |
2 | 7 | 2013.08 | 105 | 8.05 | 1618 | 1368 | 1.69 / 1160.24 | 17 | 18 |
3 | 13 | 1950.88 | 36 | 12.76 | 1664 | 764 | 2.46 / 1161.00 | 5 | 43 |
4 | 13 | 1852.88 | 36 | 12.91 | 1596 | 742 | 3.20 / 1161.75 | 5 | 44 |
5 | 13 | 1313.52 | 36 | 13.28 | 1247 | 596 | 3.80 / 1162.34 | 5 | 52 |
6 | 13 | 887.56 | 36 | 13.53 | 960 | 468 | 4.26 / 1162.81 | 5 | 55 |
7 | 13 | 428.32 | 36 | 13.86 | 608 | 303 | 4.57 / 1163.11 | 5 | 49 |
8 | 13 | 18.96 | 36 | 14.23 | 295 | 151 | 4.72 / 1163.26 | 6 | 41 |
9 | 8 | 0.08 | 450 | 14.26 | 271 | 1739 | 6.46 / 1165.00 | 6 | 67 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 69 | 14.19 | 340 | 333 | 0.33 / 1152.49 | 6 | 16 |
2 | 7 | 2001.56 | 105 | 8.18 | 1618 | 1390 | 1.72 / 1153.88 | 5 | 20 |
3 | 13 | 1931.52 | 36 | 12.79 | 1654 | 762 | 2.48 / 1154.64 | 5 | 43 |
4 | 13 | 1844.88 | 36 | 12.93 | 1598 | 744 | 3.23 / 1155.38 | 5 | 45 |
5 | 13 | 1327.08 | 36 | 13.27 | 1264 | 604 | 3.83 / 1155.99 | 5 | 53 |
6 | 13 | 794.40 | 36 | 13.59 | 884 | 432 | 4.26 / 1156.42 | 5 | 54 |
7 | 13 | 256.08 | 36 | 14.02 | 476 | 240 | 4.50 / 1156.66 | 5 | 44 |
8 | 13 | 26.08 | 36 | 14.24 | 300 | 154 | 4.66 / 1156.81 | 6 | 41 |
9 | 8 | 0.12 | 450 | 14.26 | 270 | 1733 | 6.39 / 1158.55 | 6 | 58 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 69 | 14.17 | 345 | 337 | 0.34 / 1146.17 | 6 | 16 |
2 | 7 | 2014.04 | 105 | 8.30 | 1626 | 1417 | 1.75 / 1147.59 | 16 | 19 |
3 | 13 | 1944.20 | 36 | 12.78 | 1664 | 766 | 2.52 / 1148.35 | 5 | 42 |
4 | 13 | 1649.20 | 36 | 13.08 | 1478 | 696 | 3.22 / 1149.05 | 5 | 48 |
5 | 13 | 1556.28 | 36 | 13.14 | 1417 | 670 | 3.89 / 1149.72 | 5 | 50 |
6 | 13 | 994.48 | 36 | 13.47 | 1025 | 497 | 4.38 / 1150.22 | 5 | 55 |
7 | 13 | 215.08 | 36 | 14.06 | 443 | 224 | 4.61 / 1150.44 | 5 | 43 |
8 | 8 | 0.08 | 450 | 14.27 | 267 | 1715 | 6.32 / 1152.16 | 6 | 58 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 68 | 14.18 | 334 | 322 | 0.32 / 1139.74 | 6 | 16 |
2 | 3 | 1010.56 | 1 | 12.81 | 1017 | 13 | 0.34 / 1139.76 | 5 | 5 |
3 | 7 | 2002.76 | 105 | 8.44 | 1601 | 1419 | 1.75 / 1141.18 | 5 | 20 |
4 | 13 | 1940.16 | 36 | 12.77 | 1656 | 761 | 2.52 / 1141.94 | 5 | 42 |
5 | 13 | 1847.88 | 36 | 12.92 | 1595 | 742 | 3.26 / 1142.68 | 5 | 45 |
6 | 13 | 1317.44 | 36 | 13.27 | 1255 | 600 | 3.86 / 1143.28 | 5 | 52 |
7 | 13 | 785.60 | 36 | 13.57 | 882 | 431 | 4.29 / 1143.71 | 5 | 54 |
8 | 13 | 232.08 | 36 | 14.02 | 457 | 231 | 4.52 / 1143.94 | 5 | 45 |
9 | 13 | 21.76 | 36 | 14.24 | 297 | 152 | 4.67 / 1144.09 | 6 | 43 |
10 | 8 | 0.08 | 450 | 14.23 | 272 | 1742 | 6.41 / 1145.83 | 6 | 62 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 68 | 14.15 | 344 | 331 | 0.33 / 1133.34 | 6 | 17 |
2 | 3 | 1011.72 | 1 | 12.86 | 1022 | 13 | 0.34 / 1133.35 | 5 | 6 |
3 | 7 | 2002.12 | 105 | 8.48 | 1607 | 1431 | 1.78 / 1134.78 | 6 | 21 |
4 | 13 | 1930.80 | 36 | 12.80 | 1643 | 757 | 2.53 / 1135.54 | 5 | 43 |
5 | 13 | 1837.28 | 36 | 12.93 | 1588 | 739 | 3.27 / 1136.28 | 5 | 45 |
6 | 13 | 1300.88 | 36 | 13.28 | 1239 | 592 | 3.86 / 1136.87 | 5 | 53 |
7 | 13 | 676.84 | 36 | 13.65 | 796 | 391 | 4.25 / 1137.26 | 5 | 53 |
8 | 13 | 359.44 | 36 | 13.90 | 554 | 277 | 4.53 / 1137.54 | 5 | 48 |
9 | 13 | 21.04 | 36 | 14.23 | 289 | 148 | 4.68 / 1137.69 | 6 | 42 |
10 | 8 | 0.08 | 450 | 14.25 | 270 | 1731 | 6.41 / 1139.42 | 6 | 61 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 66 | 14.13 | 345 | 322 | 0.32 / 1127.05 | 6 | 18 |
2 | 3 | 1027.20 | 1 | 13.04 | 1018 | 13 | 0.34 / 1127.06 | 5 | 14 |
3 | 7 | 2002.72 | 105 | 8.51 | 1620 | 1448 | 1.78 / 1128.51 | 14 | 23 |
4 | 13 | 1938.16 | 36 | 12.78 | 1663 | 765 | 2.55 / 1129.27 | 5 | 45 |
5 | 13 | 1841.48 | 36 | 12.93 | 1596 | 743 | 3.29 / 1130.02 | 5 | 48 |
6 | 13 | 1316.64 | 36 | 13.27 | 1248 | 596 | 3.89 / 1130.61 | 5 | 55 |
7 | 13 | 773.32 | 36 | 13.59 | 874 | 428 | 4.31 / 1131.04 | 5 | 56 |
8 | 13 | 218.52 | 36 | 14.04 | 451 | 228 | 4.54 / 1131.27 | 5 | 45 |
9 | 8 | 0.12 | 450 | 14.24 | 272 | 1743 | 6.29 / 1133.01 | 6 | 63 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 69 | 14.16 | 337 | 329 | 0.33 / 1120.74 | 6 | 20 |
2 | 3 | 962.48 | -1 | 14.16 | 337 | 0 | 0.00 / 1120.74 | 6 | 20 |
3 | 7 | 2002.04 | 105 | 8.58 | 1623 | 1462 | 1.79 / 1122.20 | 20 | 23 |
4 | 13 | 1941.84 | 36 | 12.77 | 1663 | 765 | 2.56 / 1122.97 | 5 | 44 |
5 | 13 | 1845.32 | 36 | 12.93 | 1596 | 743 | 3.30 / 1123.71 | 5 | 46 |
6 | 13 | 1305.88 | 36 | 13.28 | 1244 | 595 | 3.89 / 1124.31 | 5 | 54 |
7 | 13 | 772.04 | 36 | 13.60 | 867 | 424 | 4.32 / 1124.73 | 5 | 55 |
8 | 13 | 324.44 | 36 | 13.95 | 527 | 265 | 4.58 / 1124.99 | 5 | 48 |
9 | 8 | 0.16 | 450 | 14.24 | 270 | 1730 | 6.31 / 1126.72 | 6 | 68 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 69 | 14.18 | 340 | 333 | 0.33 / 1114.41 | 6 | 19 |
2 | 7 | 2006.12 | 106 | 8.51 | 1623 | 1464 | 1.80 / 1115.87 | 19 | 22 |
3 | 13 | 1940.72 | 36 | 12.80 | 1654 | 762 | 2.56 / 1116.64 | 5 | 42 |
4 | 13 | 1860.72 | 36 | 12.93 | 1607 | 748 | 3.31 / 1117.38 | 5 | 46 |
5 | 13 | 1360.16 | 36 | 13.25 | 1277 | 609 | 3.92 / 1117.99 | 5 | 52 |
6 | 13 | 929.72 | 36 | 13.50 | 972 | 472 | 4.39 / 1118.47 | 5 | 54 |
7 | 13 | 157.84 | 36 | 14.12 | 400 | 203 | 4.59 / 1118.67 | 5 | 43 |
8 | 8 | 0.16 | 450 | 14.24 | 272 | 1743 | 6.33 / 1120.41 | 6 | 56 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 69 | 14.16 | 351 | 343 | 0.34 / 1108.12 | 6 | 20 |
2 | 7 | 2004.80 | 105 | 8.55 | 1621 | 1455 | 1.80 / 1109.57 | 20 | 20 |
3 | 13 | 1940.00 | 36 | 12.80 | 1655 | 763 | 2.56 / 1110.33 | 5 | 42 |
4 | 13 | 1848.44 | 36 | 12.94 | 1595 | 743 | 3.30 / 1111.08 | 5 | 45 |
5 | 13 | 1416.56 | 36 | 13.24 | 1318 | 628 | 3.93 / 1111.71 | 5 | 51 |
6 | 13 | 859.32 | 36 | 13.55 | 926 | 452 | 4.38 / 1112.16 | 5 | 54 |
7 | 13 | 116.64 | 36 | 14.17 | 366 | 187 | 4.57 / 1112.34 | 6 | 40 |
8 | 8 | 0.12 | 450 | 14.26 | 270 | 1733 | 6.30 / 1114.08 | 6 | 67 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 69 | 14.16 | 350 | 342 | 0.34 / 1101.80 | 6 | 19 |
2 | 7 | 2006.12 | 105 | 8.60 | 1621 | 1464 | 1.81 / 1103.27 | 5 | 21 |
3 | 13 | 1934.32 | 36 | 12.83 | 1646 | 760 | 2.57 / 1104.03 | 5 | 41 |
4 | 13 | 1840.16 | 36 | 12.94 | 1585 | 738 | 3.30 / 1104.77 | 5 | 44 |
5 | 13 | 1418.64 | 36 | 13.23 | 1316 | 627 | 3.93 / 1105.39 | 5 | 51 |
6 | 13 | 753.88 | 36 | 13.61 | 854 | 418 | 4.35 / 1105.81 | 5 | 53 |
7 | 13 | 198.52 | 36 | 14.08 | 432 | 219 | 4.57 / 1106.03 | 5 | 43 |
8 | 8 | 0.00 | 450 | 14.25 | 272 | 1744 | 6.31 / 1107.77 | 6 | 57 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 69 | 14.14 | 339 | 331 | 0.33 / 1095.59 | 6 | 19 |
2 | 7 | 2006.16 | 106 | 8.63 | 1619 | 1481 | 1.81 / 1097.07 | 19 | 22 |
3 | 13 | 1946.44 | 36 | 12.82 | 1656 | 764 | 2.58 / 1097.83 | 5 | 42 |
4 | 13 | 1851.72 | 36 | 12.95 | 1594 | 743 | 3.32 / 1098.58 | 5 | 45 |
5 | 13 | 1203.56 | 36 | 13.33 | 1166 | 560 | 3.88 / 1099.14 | 5 | 52 |
6 | 13 | 781.56 | 36 | 13.59 | 873 | 427 | 4.31 / 1099.56 | 5 | 53 |
7 | 13 | 134.04 | 36 | 14.17 | 373 | 190 | 4.50 / 1099.75 | 6 | 40 |
8 | 8 | 0.36 | 450 | 14.27 | 266 | 1708 | 6.20 / 1101.46 | 6 | 57 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 69 | 14.17 | 348 | 340 | 0.34 / 1089.40 | 6 | 20 |
2 | 7 | 2001.44 | 105 | 8.77 | 1618 | 1490 | 1.83 / 1090.89 | 20 | 22 |
3 | 13 | 1927.40 | 36 | 12.85 | 1635 | 756 | 2.59 / 1091.64 | 5 | 41 |
4 | 13 | 1834.72 | 36 | 12.96 | 1580 | 737 | 3.32 / 1092.38 | 5 | 45 |
5 | 13 | 1214.48 | 36 | 13.35 | 1174 | 564 | 3.89 / 1092.95 | 5 | 52 |
6 | 13 | 678.68 | 36 | 13.68 | 795 | 392 | 4.28 / 1093.34 | 5 | 52 |
7 | 13 | 140.04 | 36 | 14.14 | 384 | 195 | 4.47 / 1093.53 | 5 | 41 |
8 | 8 | -0.12 | 450 | 14.25 | 269 | 1725 | 6.20 / 1095.26 | 6 | 57 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 69 | 14.15 | 347 | 339 | 0.34 / 1083.02 | 6 | 19 |
2 | 7 | 2007.20 | 105 | 8.82 | 1627 | 1507 | 1.85 / 1084.53 | 5 | 23 |
3 | 13 | 1943.36 | 36 | 12.85 | 1654 | 765 | 2.61 / 1085.29 | 5 | 42 |
4 | 13 | 1852.00 | 36 | 12.96 | 1599 | 746 | 3.36 / 1086.04 | 5 | 45 |
5 | 13 | 1317.92 | 36 | 13.28 | 1247 | 596 | 3.95 / 1086.63 | 5 | 51 |
6 | 13 | 763.00 | 36 | 13.62 | 856 | 420 | 4.37 / 1087.05 | 5 | 53 |
7 | 13 | 316.36 | 36 | 13.97 | 521 | 262 | 4.63 / 1087.31 | 5 | 46 |
8 | 8 | 0.04 | 450 | 14.24 | 272 | 1743 | 6.38 / 1089.06 | 6 | 63 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 69 | 14.16 | 345 | 337 | 0.34 / 1076.64 | 6 | 20 |
2 | 7 | 2005.64 | 105 | 8.86 | 1619 | 1506 | 1.84 / 1078.15 | 20 | 23 |
3 | 13 | 1939.24 | 36 | 12.84 | 1653 | 764 | 2.61 / 1078.91 | 5 | 42 |
4 | 13 | 1554.48 | 36 | 13.15 | 1414 | 669 | 3.28 / 1079.58 | 5 | 48 |
5 | 13 | 1458.00 | 36 | 13.19 | 1344 | 638 | 3.91 / 1080.22 | 5 | 50 |
6 | 13 | 668.00 | 36 | 13.68 | 786 | 387 | 4.30 / 1080.61 | 5 | 53 |
7 | 13 | 138.68 | 36 | 14.16 | 384 | 196 | 4.50 / 1080.81 | 6 | 41 |
8 | 13 | 13.08 | 36 | 14.28 | 288 | 148 | 4.65 / 1080.95 | 6 | 40 |
9 | 8 | 0.12 | 450 | 14.26 | 269 | 1726 | 6.37 / 1082.68 | 6 | 60 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 69 | 14.16 | 354 | 346 | 0.35 / 1070.37 | 6 | 19 |
2 | 7 | 2007.20 | 105 | 8.98 | 1627 | 1534 | 1.88 / 1071.90 | 19 | 23 |
3 | 13 | 1937.84 | 36 | 12.81 | 1653 | 762 | 2.64 / 1072.66 | 5 | 43 |
4 | 13 | 1851.04 | 36 | 12.96 | 1596 | 745 | 3.39 / 1073.41 | 5 | 46 |
5 | 13 | 1196.80 | 36 | 13.35 | 1169 | 562 | 3.95 / 1073.97 | 5 | 54 |
6 | 13 | 748.28 | 36 | 13.61 | 843 | 413 | 4.36 / 1074.38 | 5 | 55 |
7 | 13 | 102.16 | 36 | 14.20 | 354 | 181 | 4.54 / 1074.56 | 6 | 41 |
8 | 8 | 0.00 | 450 | 14.25 | 272 | 1744 | 6.29 / 1076.31 | 6 | 66 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 66 | 14.18 | 339 | 317 | 0.32 / 1063.98 | 6 | 19 |
2 | 3 | 1050.76 | 3 | 13.26 | 1022 | 41 | 0.36 / 1064.02 | 5 | 26 |
3 | 7 | 2002.92 | 106 | 9.07 | 1629 | 1566 | 1.92 / 1065.59 | 26 | 25 |
4 | 13 | 1926.88 | 36 | 12.83 | 1641 | 758 | 2.68 / 1066.35 | 5 | 43 |
5 | 13 | 1829.92 | 36 | 12.96 | 1576 | 735 | 3.42 / 1067.08 | 5 | 46 |
6 | 13 | 1301.92 | 36 | 13.29 | 1241 | 594 | 4.01 / 1067.68 | 5 | 53 |
7 | 13 | 738.64 | 36 | 13.60 | 837 | 410 | 4.42 / 1068.09 | 5 | 55 |
8 | 13 | 96.88 | 36 | 14.20 | 351 | 179 | 4.60 / 1068.26 | 6 | 41 |
9 | 8 | 0.28 | 450 | 14.24 | 274 | 1756 | 6.36 / 1070.02 | 6 | 58 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 69 | 14.18 | 337 | 330 | 0.33 / 1057.68 | 6 | 19 |
2 | 3 | 959.68 | -1 | 14.18 | 337 | 0 | 0.00 / 1057.68 | 6 | 19 |
3 | 7 | 2011.12 | 105 | 8.96 | 1629 | 1533 | 1.86 / 1059.21 | 19 | 24 |
4 | 13 | 1953.64 | 36 | 12.82 | 1663 | 768 | 2.63 / 1059.98 | 5 | 43 |
5 | 13 | 1859.40 | 36 | 12.94 | 1606 | 748 | 3.38 / 1060.73 | 5 | 45 |
6 | 13 | 1223.08 | 36 | 13.33 | 1184 | 568 | 3.95 / 1061.30 | 5 | 53 |
7 | 13 | 774.08 | 36 | 13.59 | 875 | 428 | 4.37 / 1061.72 | 5 | 55 |
8 | 13 | 230.16 | 36 | 14.07 | 448 | 227 | 4.60 / 1061.95 | 5 | 45 |
9 | 8 | 0.04 | 450 | 14.26 | 267 | 1713 | 6.31 / 1063.66 | 6 | 60 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 69 | 14.24 | 340 | 334 | 0.33 / 1051.41 | 6 | 19 |
2 | 7 | 2002.60 | 105 | 8.94 | 1615 | 1516 | 1.85 / 1052.93 | 19 | 24 |
3 | 13 | 1925.28 | 36 | 12.83 | 1648 | 761 | 2.61 / 1053.69 | 5 | 42 |
4 | 13 | 1831.80 | 36 | 12.96 | 1582 | 738 | 3.35 / 1054.43 | 5 | 45 |
5 | 13 | 1107.76 | 36 | 13.39 | 1098 | 529 | 3.88 / 1054.96 | 5 | 53 |
6 | 13 | 784.72 | 36 | 13.58 | 873 | 427 | 4.31 / 1055.38 | 5 | 54 |
7 | 13 | 318.72 | 36 | 13.98 | 519 | 261 | 4.57 / 1055.64 | 5 | 46 |
8 | 8 | 0.16 | 450 | 14.26 | 266 | 1707 | 6.27 / 1057.35 | 6 | 59 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 69 | 14.20 | 339 | 332 | 0.33 / 1045.14 | 6 | 18 |
2 | 7 | 2006.48 | 105 | 9.03 | 1628 | 1544 | 1.88 / 1046.68 | 18 | 24 |
3 | 13 | 1935.84 | 36 | 12.84 | 1653 | 764 | 2.64 / 1047.45 | 5 | 42 |
4 | 13 | 1845.80 | 36 | 12.96 | 1592 | 743 | 3.38 / 1048.19 | 5 | 45 |
5 | 13 | 1275.12 | 36 | 13.32 | 1214 | 582 | 3.96 / 1048.77 | 5 | 52 |
6 | 13 | 737.64 | 36 | 13.63 | 834 | 409 | 4.37 / 1049.18 | 5 | 53 |
7 | 13 | 47.08 | 36 | 14.28 | 309 | 159 | 4.53 / 1049.34 | 6 | 39 |
8 | 8 | -0.04 | 450 | 14.28 | 270 | 1735 | 6.27 / 1051.08 | 6 | 63 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 69 | 14.17 | 351 | 343 | 0.34 / 1038.84 | 6 | 17 |
2 | 7 | 2013.36 | 105 | 9.09 | 1635 | 1561 | 1.90 / 1040.41 | 5 | 24 |
3 | 13 | 1947.16 | 36 | 12.84 | 1662 | 768 | 2.67 / 1041.17 | 5 | 43 |
4 | 13 | 1853.36 | 36 | 12.95 | 1604 | 748 | 3.42 / 1041.92 | 5 | 45 |
5 | 13 | 1205.68 | 36 | 13.35 | 1174 | 564 | 3.98 / 1042.49 | 5 | 52 |
6 | 13 | 683.52 | 36 | 13.67 | 801 | 394 | 4.38 / 1042.88 | 5 | 53 |
7 | 13 | 139.84 | 36 | 14.16 | 383 | 195 | 4.57 / 1043.07 | 5 | 42 |
8 | 8 | 0.12 | 450 | 14.27 | 270 | 1734 | 6.31 / 1044.81 | 6 | 58 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 69 | 14.22 | 340 | 334 | 0.33 / 1032.50 | 6 | 17 |
2 | 7 | 2011.92 | 105 | 9.06 | 1635 | 1555 | 1.89 / 1034.05 | 17 | 24 |
3 | 13 | 1943.16 | 36 | 12.87 | 1658 | 768 | 2.66 / 1034.82 | 5 | 43 |
4 | 13 | 1852.48 | 36 | 12.99 | 1596 | 746 | 3.40 / 1035.57 | 5 | 45 |
5 | 13 | 1188.16 | 36 | 13.35 | 1168 | 561 | 3.96 / 1036.13 | 5 | 53 |
6 | 13 | 868.24 | 36 | 13.54 | 938 | 457 | 4.42 / 1036.58 | 5 | 54 |
7 | 13 | 91.20 | 36 | 14.22 | 348 | 178 | 4.60 / 1036.76 | 6 | 42 |
8 | 8 | 0.08 | 450 | 14.26 | 271 | 1739 | 6.34 / 1038.50 | 6 | 62 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 69 | 14.22 | 343 | 337 | 0.34 / 1026.08 | 6 | 16 |
2 | 7 | 2001.48 | 105 | 9.13 | 1626 | 1559 | 1.90 / 1027.64 | 5 | 25 |
3 | 13 | 1926.92 | 36 | 12.85 | 1646 | 761 | 2.66 / 1028.40 | 5 | 43 |
4 | 13 | 1838.76 | 36 | 12.95 | 1595 | 744 | 3.40 / 1029.14 | 5 | 45 |
5 | 13 | 1300.52 | 36 | 13.28 | 1241 | 593 | 3.99 / 1029.73 | 5 | 52 |
6 | 13 | 950.60 | 36 | 13.48 | 998 | 484 | 4.48 / 1030.22 | 5 | 55 |
7 | 13 | 157.12 | 36 | 14.14 | 401 | 204 | 4.68 / 1030.42 | 6 | 42 |
8 | 8 | 0.08 | 450 | 14.27 | 271 | 1740 | 6.42 / 1032.16 | 6 | 60 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 67 | 14.25 | 336 | 321 | 0.32 / 1019.84 | 6 | 16 |
2 | 3 | 1037.40 | 2 | 13.11 | 1031 | 27 | 0.35 / 1019.87 | 5 | 19 |
3 | 7 | 2005.76 | 105 | 9.22 | 1624 | 1572 | 1.92 / 1021.44 | 19 | 25 |
4 | 13 | 1922.00 | 36 | 12.87 | 1637 | 758 | 2.68 / 1022.20 | 5 | 42 |
5 | 13 | 1828.24 | 36 | 12.96 | 1586 | 740 | 3.42 / 1022.94 | 5 | 45 |
6 | 13 | 1087.40 | 36 | 13.40 | 1090 | 526 | 3.94 / 1023.47 | 5 | 52 |
7 | 13 | 672.88 | 36 | 13.69 | 788 | 388 | 4.33 / 1023.85 | 5 | 53 |
8 | 13 | 69.24 | 36 | 14.26 | 330 | 169 | 4.50 / 1024.02 | 6 | 39 |
9 | 8 | 0.12 | 450 | 14.28 | 267 | 1716 | 6.22 / 1025.74 | 6 | 59 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 70 | 14.26 | 334 | 333 | 0.33 / 1013.65 | 6 | 15 |
2 | 3 | 965.52 | -1 | 14.26 | 334 | 0 | 0.00 / 1013.65 | 6 | 15 |
3 | 7 | 2002.76 | 105 | 9.21 | 1623 | 1570 | 1.90 / 1015.22 | 15 | 25 |
4 | 13 | 1932.40 | 36 | 12.85 | 1650 | 763 | 2.67 / 1015.98 | 5 | 42 |
5 | 13 | 1838.80 | 36 | 12.98 | 1588 | 742 | 3.41 / 1016.72 | 5 | 45 |
6 | 13 | 1089.72 | 36 | 13.41 | 1083 | 523 | 3.93 / 1017.25 | 5 | 52 |
7 | 13 | 666.12 | 36 | 13.68 | 783 | 386 | 4.32 / 1017.63 | 5 | 52 |
8 | 13 | 120.24 | 36 | 14.21 | 364 | 186 | 4.50 / 1017.82 | 6 | 41 |
9 | 8 | 0.12 | 450 | 14.29 | 265 | 1704 | 6.21 / 1019.52 | 6 | 57 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 70 | 14.28 | 334 | 334 | 0.33 / 1007.40 | 6 | 15 |
2 | 7 | 2010.48 | 105 | 9.23 | 1629 | 1579 | 1.91 / 1008.98 | 15 | 25 |
3 | 13 | 1936.20 | 36 | 12.86 | 1650 | 764 | 2.68 / 1009.74 | 5 | 41 |
4 | 13 | 1841.00 | 36 | 12.96 | 1597 | 745 | 3.42 / 1010.49 | 5 | 45 |
5 | 13 | 1114.12 | 36 | 13.40 | 1106 | 534 | 3.96 / 1011.02 | 5 | 52 |
6 | 13 | 612.96 | 36 | 13.75 | 743 | 368 | 4.32 / 1011.39 | 5 | 50 |
7 | 13 | 162.36 | 36 | 14.16 | 401 | 204 | 4.53 / 1011.59 | 6 | 42 |
8 | 8 | 0.24 | 450 | 14.28 | 268 | 1722 | 6.25 / 1013.32 | 6 | 60 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 70 | 14.25 | 340 | 339 | 0.34 / 1001.02 | 6 | 14 |
2 | 7 | 2002.00 | 105 | 9.20 | 1629 | 1574 | 1.91 / 1002.59 | 14 | 24 |
3 | 13 | 1932.80 | 36 | 12.85 | 1651 | 764 | 2.68 / 1003.36 | 5 | 42 |
4 | 13 | 1839.28 | 36 | 12.97 | 1592 | 743 | 3.42 / 1004.10 | 5 | 45 |
5 | 13 | 1384.80 | 36 | 13.25 | 1291 | 616 | 4.04 / 1004.72 | 5 | 51 |
6 | 13 | 516.72 | 36 | 13.83 | 669 | 333 | 4.37 / 1005.05 | 5 | 49 |
7 | 13 | 60.16 | 36 | 14.28 | 318 | 163 | 4.53 / 1005.21 | 6 | 39 |
8 | 13 | 30.92 | 36 | 14.29 | 295 | 152 | 4.68 / 1005.37 | 6 | 40 |
9 | 8 | 0.20 | 450 | 14.31 | 264 | 1700 | 6.38 / 1007.07 | 6 | 58 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 70 | 14.26 | 342 | 341 | 0.34 / 994.71 | 6 | 14 |
2 | 7 | 2012.36 | 105 | 9.27 | 1625 | 1582 | 1.92 / 996.29 | 14 | 25 |
3 | 13 | 1941.24 | 36 | 12.87 | 1653 | 766 | 2.69 / 997.05 | 5 | 42 |
4 | 13 | 1848.28 | 36 | 12.97 | 1602 | 748 | 3.44 / 997.80 | 5 | 45 |
5 | 13 | 1208.92 | 36 | 13.35 | 1176 | 565 | 4.00 / 998.37 | 5 | 52 |
6 | 13 | 774.44 | 36 | 13.62 | 872 | 428 | 4.43 / 998.79 | 5 | 53 |
7 | 13 | 104.48 | 36 | 14.22 | 358 | 183 | 4.61 / 998.98 | 6 | 41 |
8 | 8 | 0.04 | 450 | 14.29 | 265 | 1704 | 6.32 / 1000.68 | 6 | 55 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 70 | 14.27 | 342 | 342 | 0.34 / 988.43 | 6 | 14 |
2 | 7 | 2002.92 | 105 | 9.41 | 1631 | 1612 | 1.95 / 990.04 | 14 | 26 |
3 | 13 | 1927.04 | 36 | 12.86 | 1644 | 761 | 2.71 / 990.81 | 5 | 42 |
4 | 13 | 1732.96 | 36 | 13.05 | 1523 | 716 | 3.43 / 991.52 | 5 | 46 |
5 | 13 | 1201.00 | 36 | 13.36 | 1163 | 559 | 3.99 / 992.08 | 5 | 52 |
6 | 13 | 664.36 | 36 | 13.71 | 779 | 384 | 4.37 / 992.47 | 5 | 53 |
7 | 13 | 105.16 | 36 | 14.22 | 357 | 183 | 4.56 / 992.65 | 6 | 41 |
8 | 8 | 0.08 | 450 | 14.29 | 267 | 1717 | 6.27 / 994.36 | 6 | 60 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 70 | 14.27 | 337 | 337 | 0.34 / 982.26 | 6 | 14 |
2 | 7 | 2007.64 | 105 | 9.37 | 1622 | 1596 | 1.93 / 983.86 | 5 | 26 |
3 | 13 | 1929.00 | 36 | 12.87 | 1648 | 764 | 2.70 / 984.62 | 5 | 42 |
4 | 13 | 1834.68 | 36 | 12.97 | 1588 | 741 | 3.44 / 985.36 | 5 | 45 |
5 | 13 | 1006.68 | 36 | 13.46 | 1030 | 499 | 3.94 / 985.86 | 5 | 52 |
6 | 13 | 587.40 | 36 | 13.75 | 719 | 356 | 4.29 / 986.22 | 5 | 51 |
7 | 13 | 82.52 | 36 | 14.25 | 338 | 173 | 4.47 / 986.39 | 6 | 41 |
8 | 8 | 0.08 | 450 | 14.30 | 264 | 1699 | 6.16 / 988.09 | 6 | 57 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 70 | 14.26 | 334 | 333 | 0.33 / 975.88 | 6 | 13 |
2 | 7 | 2003.84 | 105 | 9.43 | 1619 | 1603 | 1.94 / 977.48 | 5 | 26 |
3 | 13 | 1933.04 | 36 | 12.87 | 1648 | 764 | 2.70 / 978.25 | 5 | 42 |
4 | 13 | 1837.04 | 36 | 12.98 | 1590 | 743 | 3.44 / 978.99 | 5 | 45 |
5 | 13 | 1394.72 | 36 | 13.26 | 1296 | 619 | 4.06 / 979.61 | 5 | 51 |
6 | 13 | 717.92 | 36 | 13.66 | 817 | 402 | 4.46 / 980.01 | 5 | 53 |
7 | 13 | 169.60 | 36 | 14.16 | 404 | 206 | 4.67 / 980.22 | 6 | 42 |
8 | 8 | 0.04 | 450 | 14.29 | 266 | 1711 | 6.38 / 981.93 | 6 | 63 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 70 | 14.31 | 328 | 329 | 0.33 / 969.58 | 6 | 13 |
2 | 7 | 2004.16 | 106 | 9.39 | 1628 | 1620 | 1.95 / 971.20 | 13 | 25 |
3 | 13 | 1932.88 | 36 | 12.88 | 1648 | 764 | 2.71 / 971.96 | 5 | 41 |
4 | 13 | 1539.12 | 36 | 13.17 | 1401 | 664 | 3.38 / 972.63 | 5 | 48 |
5 | 13 | 1123.04 | 36 | 13.39 | 1118 | 539 | 3.92 / 973.17 | 5 | 52 |
6 | 13 | 591.80 | 36 | 13.76 | 727 | 360 | 4.28 / 973.53 | 5 | 50 |
7 | 13 | 72.04 | 36 | 14.27 | 326 | 167 | 4.44 / 973.70 | 6 | 40 |
8 | 13 | 15.04 | 36 | 14.33 | 286 | 148 | 4.59 / 973.84 | 6 | 41 |
9 | 8 | 0.04 | 450 | 14.29 | 265 | 1704 | 6.30 / 975.55 | 7 | 64 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 69 | 14.32 | 330 | 326 | 0.33 / 963.20 | 6 | 13 |
2 | 7 | 2006.92 | 106 | 9.50 | 1606 | 1617 | 1.94 / 964.81 | 5 | 26 |
3 | 13 | 1936.88 | 36 | 12.87 | 1640 | 760 | 2.70 / 965.57 | 5 | 42 |
4 | 13 | 1840.76 | 36 | 12.98 | 1578 | 737 | 3.44 / 966.31 | 5 | 45 |
5 | 13 | 1185.04 | 36 | 13.37 | 1155 | 556 | 4.00 / 966.87 | 5 | 52 |
6 | 13 | 625.96 | 36 | 13.75 | 750 | 371 | 4.37 / 967.24 | 5 | 50 |
7 | 13 | 94.40 | 36 | 14.25 | 346 | 177 | 4.55 / 967.42 | 6 | 40 |
8 | 13 | 20.24 | 36 | 14.33 | 291 | 150 | 4.70 / 967.57 | 6 | 41 |
9 | 8 | 0.08 | 450 | 14.30 | 262 | 1686 | 6.38 / 969.25 | 6 | 57 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 69 | 14.29 | 337 | 332 | 0.33 / 956.77 | 6 | 13 |
2 | 7 | 2007.12 | 106 | 9.48 | 1633 | 1641 | 1.97 / 958.41 | 13 | 26 |
3 | 13 | 1926.36 | 36 | 12.86 | 1644 | 761 | 2.73 / 959.18 | 5 | 42 |
4 | 13 | 1835.16 | 36 | 12.98 | 1585 | 741 | 3.47 / 959.92 | 5 | 44 |
5 | 13 | 1169.56 | 36 | 13.36 | 1151 | 554 | 4.03 / 960.47 | 5 | 52 |
6 | 13 | 650.56 | 36 | 13.72 | 773 | 382 | 4.41 / 960.85 | 5 | 51 |
7 | 13 | 50.84 | 36 | 14.29 | 315 | 162 | 4.57 / 961.01 | 6 | 40 |
8 | 13 | 11.52 | 36 | 14.33 | 284 | 147 | 4.72 / 961.16 | 6 | 41 |
9 | 8 | 0.04 | 450 | 14.29 | 266 | 1711 | 6.43 / 962.87 | 6 | 64 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 69 | 14.29 | 333 | 328 | 0.33 / 950.38 | 6 | 14 |
2 | 7 | 2002.04 | 105 | 9.54 | 1626 | 1629 | 1.96 / 952.01 | 14 | 26 |
3 | 13 | 1926.60 | 36 | 12.87 | 1645 | 762 | 2.72 / 952.77 | 5 | 42 |
4 | 13 | 1634.60 | 36 | 13.12 | 1461 | 690 | 3.41 / 953.46 | 5 | 47 |
5 | 13 | 1118.00 | 36 | 13.37 | 1114 | 536 | 3.95 / 953.99 | 5 | 53 |
6 | 13 | 785.88 | 36 | 13.61 | 870 | 426 | 4.37 / 954.42 | 5 | 53 |
7 | 13 | 54.48 | 36 | 14.29 | 317 | 163 | 4.53 / 954.58 | 6 | 41 |
8 | 13 | 13.20 | 36 | 14.33 | 285 | 147 | 4.68 / 954.73 | 6 | 41 |
9 | 8 | 0.08 | 450 | 14.29 | 266 | 1711 | 6.39 / 956.44 | 6 | 56 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 69 | 14.27 | 340 | 335 | 0.33 / 944.06 | 6 | 14 |
2 | 7 | 2001.56 | 105 | 9.63 | 1635 | 1653 | 1.99 / 945.71 | 14 | 27 |
3 | 13 | 1920.12 | 36 | 12.87 | 1637 | 758 | 2.75 / 946.47 | 5 | 43 |
4 | 13 | 1729.12 | 36 | 13.05 | 1526 | 717 | 3.46 / 947.19 | 5 | 47 |
5 | 13 | 979.36 | 36 | 13.46 | 1023 | 496 | 3.96 / 947.68 | 5 | 53 |
6 | 13 | 479.48 | 36 | 13.86 | 648 | 323 | 4.28 / 948.01 | 5 | 49 |
7 | 13 | 72.24 | 36 | 14.27 | 335 | 172 | 4.45 / 948.18 | 6 | 41 |
8 | 13 | 14.44 | 36 | 14.32 | 289 | 149 | 4.60 / 948.33 | 6 | 41 |
9 | 8 | 0.04 | 450 | 14.27 | 268 | 1721 | 6.32 / 950.05 | 6 | 65 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 69 | 14.26 | 340 | 335 | 0.33 / 937.88 | 6 | 15 |
2 | 7 | 2010.16 | 105 | 9.62 | 1635 | 1652 | 1.99 / 939.53 | 15 | 27 |
3 | 13 | 1929.96 | 36 | 12.87 | 1648 | 764 | 2.75 / 940.29 | 5 | 42 |
4 | 13 | 1529.52 | 36 | 13.17 | 1399 | 663 | 3.41 / 940.96 | 5 | 49 |
5 | 13 | 1113.36 | 36 | 13.40 | 1115 | 538 | 3.95 / 941.49 | 5 | 53 |
6 | 13 | 576.16 | 36 | 13.77 | 725 | 359 | 4.31 / 941.85 | 5 | 51 |
7 | 13 | 65.56 | 36 | 14.29 | 325 | 167 | 4.48 / 942.02 | 6 | 42 |
8 | 8 | 0.04 | 450 | 14.29 | 265 | 1704 | 6.18 / 943.72 | 6 | 59 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 69 | 14.27 | 352 | 347 | 0.35 / 931.52 | 6 | 16 |
2 | 7 | 2009.16 | 105 | 9.69 | 1647 | 1676 | 2.02 / 933.19 | 16 | 28 |
3 | 13 | 1930.64 | 36 | 12.85 | 1651 | 764 | 2.79 / 933.96 | 5 | 43 |
4 | 13 | 1729.44 | 36 | 13.04 | 1523 | 715 | 3.50 / 934.67 | 5 | 47 |
5 | 13 | 1196.16 | 36 | 13.34 | 1172 | 563 | 4.06 / 935.24 | 5 | 53 |
6 | 13 | 645.04 | 36 | 13.70 | 781 | 385 | 4.45 / 935.62 | 5 | 53 |
7 | 13 | 91.16 | 36 | 14.24 | 351 | 180 | 4.63 / 935.80 | 6 | 43 |
8 | 8 | 0.12 | 450 | 14.28 | 271 | 1741 | 6.37 / 937.54 | 6 | 62 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 69 | 14.24 | 344 | 338 | 0.34 / 925.17 | 6 | 16 |
2 | 7 | 2005.56 | 105 | 9.78 | 1638 | 1682 | 2.02 / 926.85 | 16 | 28 |
3 | 13 | 1934.32 | 36 | 12.85 | 1647 | 762 | 2.78 / 927.61 | 5 | 43 |
4 | 13 | 1839.20 | 36 | 12.95 | 1592 | 742 | 3.52 / 928.35 | 5 | 46 |
5 | 13 | 1167.16 | 36 | 13.38 | 1147 | 552 | 4.08 / 928.90 | 5 | 53 |
6 | 13 | 623.20 | 36 | 13.73 | 756 | 374 | 4.45 / 929.28 | 5 | 53 |
7 | 13 | 40.92 | 36 | 14.30 | 308 | 159 | 4.61 / 929.44 | 6 | 41 |
8 | 8 | 0.08 | 450 | 14.28 | 270 | 1735 | 6.34 / 931.17 | 6 | 58 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 69 | 14.28 | 335 | 330 | 0.33 / 919.02 | 6 | 16 |
2 | 7 | 2003.08 | 106 | 9.76 | 1643 | 1700 | 2.03 / 920.72 | 16 | 28 |
3 | 13 | 1921.20 | 36 | 12.86 | 1644 | 761 | 2.79 / 921.48 | 5 | 43 |
4 | 13 | 1408.32 | 36 | 13.22 | 1313 | 625 | 3.42 / 922.11 | 5 | 50 |
5 | 13 | 1098.00 | 36 | 13.41 | 1096 | 529 | 3.94 / 922.64 | 5 | 53 |
6 | 13 | 467.84 | 36 | 13.88 | 634 | 317 | 4.26 / 922.95 | 5 | 51 |
7 | 13 | 32.12 | 36 | 14.32 | 299 | 154 | 4.42 / 923.11 | 6 | 41 |
8 | 8 | 0.16 | 450 | 14.27 | 268 | 1721 | 6.14 / 924.83 | 6 | 58 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 69 | 14.24 | 341 | 335 | 0.34 / 912.68 | 6 | 16 |
2 | 7 | 2007.92 | 105 | 9.80 | 1636 | 1683 | 2.02 / 914.36 | 16 | 28 |
3 | 13 | 1920.36 | 36 | 12.85 | 1638 | 758 | 2.78 / 915.12 | 5 | 43 |
4 | 13 | 1724.96 | 36 | 13.05 | 1519 | 714 | 3.49 / 915.83 | 5 | 47 |
5 | 13 | 1278.68 | 36 | 13.29 | 1226 | 587 | 4.08 / 916.42 | 5 | 52 |
6 | 13 | 602.04 | 36 | 13.76 | 733 | 363 | 4.44 / 916.78 | 5 | 53 |
7 | 13 | 70.40 | 36 | 14.27 | 331 | 170 | 4.61 / 916.95 | 6 | 42 |
8 | 8 | 0.04 | 450 | 14.26 | 271 | 1739 | 6.35 / 918.69 | 6 | 55 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 69 | 14.25 | 339 | 333 | 0.33 / 906.43 | 6 | 17 |
2 | 7 | 2006.44 | 105 | 9.79 | 1636 | 1682 | 2.02 / 908.11 | 17 | 28 |
3 | 13 | 1935.68 | 36 | 12.83 | 1650 | 762 | 2.78 / 908.87 | 5 | 43 |
4 | 13 | 1839.36 | 36 | 12.94 | 1594 | 743 | 3.52 / 909.61 | 5 | 46 |
5 | 13 | 1066.88 | 36 | 13.43 | 1076 | 520 | 4.04 / 910.13 | 5 | 54 |
6 | 13 | 541.92 | 36 | 13.80 | 695 | 345 | 4.39 / 910.48 | 5 | 51 |
7 | 13 | 26.84 | 36 | 14.34 | 292 | 151 | 4.54 / 910.63 | 6 | 41 |
8 | 8 | 0.12 | 450 | 14.27 | 267 | 1715 | 6.25 / 912.34 | 6 | 66 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 69 | 14.26 | 342 | 337 | 0.34 / 900.18 | 6 | 17 |
2 | 7 | 2002.40 | 105 | 9.83 | 1637 | 1690 | 2.03 / 901.87 | 17 | 28 |
3 | 13 | 1912.56 | 36 | 12.83 | 1636 | 756 | 2.78 / 902.63 | 5 | 43 |
4 | 13 | 1705.76 | 36 | 13.05 | 1508 | 708 | 3.49 / 903.34 | 5 | 47 |
5 | 13 | 1062.92 | 36 | 13.42 | 1078 | 521 | 4.01 / 903.86 | 5 | 53 |
6 | 13 | 530.60 | 36 | 13.80 | 690 | 343 | 4.35 / 904.20 | 5 | 52 |
7 | 13 | 24.24 | 36 | 14.34 | 296 | 153 | 4.51 / 904.35 | 6 | 41 |
8 | 8 | 0.04 | 450 | 14.26 | 271 | 1739 | 6.25 / 906.09 | 6 | 62 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 69 | 14.25 | 347 | 341 | 0.34 / 893.89 | 6 | 18 |
2 | 7 | 2004.92 | 105 | 9.88 | 1636 | 1697 | 2.04 / 895.58 | 18 | 29 |
3 | 13 | 1911.88 | 36 | 12.83 | 1641 | 758 | 2.80 / 896.34 | 5 | 43 |
4 | 13 | 1605.32 | 36 | 13.09 | 1447 | 682 | 3.48 / 897.02 | 5 | 49 |
5 | 13 | 1178.92 | 36 | 13.34 | 1154 | 554 | 4.03 / 897.58 | 5 | 54 |
6 | 13 | 631.72 | 36 | 13.71 | 766 | 378 | 4.41 / 897.96 | 5 | 54 |
7 | 13 | 20.32 | 36 | 14.33 | 292 | 151 | 4.56 / 898.11 | 6 | 41 |
8 | 8 | 0.12 | 450 | 14.26 | 271 | 1739 | 6.30 / 899.85 | 6 | 62 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 69 | 14.23 | 344 | 338 | 0.34 / 887.59 | 6 | 18 |
2 | 7 | 2005.04 | 106 | 9.95 | 1635 | 1724 | 2.06 / 889.32 | 18 | 29 |
3 | 13 | 1929.00 | 36 | 12.83 | 1647 | 761 | 2.82 / 890.08 | 5 | 44 |
4 | 13 | 1838.40 | 36 | 12.94 | 1593 | 742 | 3.56 / 890.82 | 5 | 46 |
5 | 13 | 968.16 | 36 | 13.48 | 1012 | 491 | 4.06 / 891.31 | 5 | 54 |
6 | 13 | 544.96 | 36 | 13.82 | 692 | 344 | 4.40 / 891.66 | 5 | 52 |
7 | 13 | 18.76 | 36 | 14.34 | 292 | 151 | 4.55 / 891.81 | 6 | 41 |
8 | 8 | 0.16 | 450 | 14.26 | 271 | 1739 | 6.29 / 893.55 | 6 | 63 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 69 | 14.25 | 350 | 344 | 0.34 / 881.38 | 6 | 19 |
2 | 7 | 2001.44 | 105 | 9.98 | 1642 | 1721 | 2.06 / 883.11 | 19 | 29 |
3 | 13 | 1918.44 | 36 | 12.84 | 1640 | 758 | 2.82 / 883.86 | 5 | 43 |
4 | 13 | 1500.40 | 36 | 13.16 | 1375 | 651 | 3.47 / 884.52 | 5 | 50 |
5 | 13 | 1192.24 | 36 | 13.34 | 1166 | 560 | 4.03 / 885.08 | 5 | 53 |
6 | 13 | 441.48 | 36 | 13.90 | 617 | 309 | 4.34 / 885.38 | 5 | 50 |
7 | 13 | 24.84 | 36 | 14.33 | 296 | 153 | 4.50 / 885.54 | 6 | 41 |
8 | 8 | 0.12 | 450 | 14.26 | 268 | 1720 | 6.22 / 887.26 | 6 | 60 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 69 | 14.22 | 344 | 338 | 0.34 / 875.06 | 6 | 19 |
2 | 7 | 2014.40 | 105 | 9.95 | 1652 | 1726 | 2.06 / 876.79 | 19 | 29 |
3 | 13 | 1938.96 | 36 | 12.84 | 1658 | 766 | 2.83 / 877.56 | 5 | 43 |
4 | 13 | 1634.04 | 36 | 13.08 | 1462 | 688 | 3.52 / 878.24 | 5 | 48 |
5 | 13 | 1095.60 | 36 | 13.40 | 1103 | 532 | 4.05 / 878.78 | 5 | 53 |
6 | 13 | 561.00 | 36 | 13.80 | 707 | 351 | 4.40 / 879.13 | 5 | 52 |
7 | 13 | 50.48 | 36 | 14.30 | 317 | 163 | 4.56 / 879.29 | 6 | 42 |
8 | 8 | 0.24 | 450 | 14.25 | 273 | 1751 | 6.32 / 881.04 | 6 | 60 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 69 | 14.23 | 342 | 336 | 0.34 / 868.64 | 6 | 19 |
2 | 7 | 2011.44 | 105 | 9.95 | 1648 | 1722 | 2.06 / 870.36 | 19 | 29 |
3 | 13 | 1930.12 | 36 | 12.83 | 1646 | 760 | 2.82 / 871.12 | 5 | 43 |
4 | 13 | 1831.52 | 36 | 12.94 | 1590 | 741 | 3.56 / 871.86 | 5 | 45 |
5 | 13 | 1360.76 | 36 | 13.25 | 1275 | 608 | 4.17 / 872.47 | 5 | 52 |
6 | 13 | 575.24 | 36 | 13.79 | 721 | 358 | 4.52 / 872.83 | 5 | 52 |
7 | 13 | 64.84 | 36 | 14.29 | 326 | 168 | 4.69 / 872.99 | 6 | 42 |
8 | 8 | -0.04 | 450 | 14.25 | 270 | 1731 | 6.42 / 874.73 | 6 | 57 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 69 | 14.22 | 352 | 345 | 0.35 / 862.40 | 6 | 19 |
2 | 7 | 2005.88 | 105 | 10.01 | 1641 | 1725 | 2.07 / 864.13 | 19 | 29 |
3 | 13 | 1922.40 | 36 | 12.82 | 1641 | 757 | 2.83 / 864.88 | 5 | 43 |
4 | 13 | 1622.64 | 36 | 13.10 | 1452 | 685 | 3.51 / 865.57 | 5 | 47 |
5 | 13 | 1097.68 | 36 | 13.40 | 1100 | 531 | 4.04 / 866.10 | 5 | 52 |
6 | 13 | 456.48 | 36 | 13.91 | 622 | 311 | 4.35 / 866.41 | 5 | 49 |
7 | 13 | 11.88 | 36 | 14.36 | 288 | 149 | 4.50 / 866.56 | 6 | 41 |
8 | 8 | 0.04 | 450 | 14.24 | 272 | 1743 | 6.25 / 868.30 | 6 | 62 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 69 | 14.25 | 341 | 335 | 0.34 / 856.30 | 6 | 18 |
2 | 7 | 2001.20 | 105 | 10.13 | 1640 | 1744 | 2.08 / 858.04 | 18 | 29 |
3 | 13 | 1921.32 | 36 | 12.81 | 1641 | 757 | 2.84 / 858.80 | 5 | 42 |
4 | 13 | 1614.88 | 36 | 13.09 | 1448 | 682 | 3.52 / 859.48 | 5 | 48 |
5 | 13 | 971.36 | 36 | 13.47 | 1012 | 491 | 4.01 / 859.97 | 5 | 53 |
6 | 13 | 546.24 | 36 | 13.83 | 688 | 343 | 4.35 / 860.31 | 5 | 51 |
7 | 8 | 0.28 | 450 | 14.24 | 272 | 1743 | 6.10 / 862.06 | 6 | 51 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 68 | 14.23 | 346 | 335 | 0.33 / 850.01 | 6 | 18 |
2 | 3 | 1026.00 | 1 | 12.87 | 1044 | 13 | 0.35 / 850.03 | 5 | 11 |
3 | 7 | 2012.52 | 106 | 10.28 | 1650 | 1798 | 2.15 / 851.82 | 11 | 30 |
4 | 13 | 1916.24 | 36 | 12.81 | 1634 | 754 | 2.90 / 852.58 | 5 | 43 |
5 | 13 | 1594.48 | 36 | 13.09 | 1434 | 676 | 3.58 / 853.25 | 5 | 48 |
6 | 13 | 1049.12 | 36 | 13.41 | 1059 | 511 | 4.09 / 853.76 | 5 | 54 |
7 | 13 | 515.20 | 36 | 13.83 | 672 | 335 | 4.42 / 854.10 | 5 | 52 |
8 | 13 | 3.76 | 36 | 14.38 | 279 | 144 | 4.57 / 854.24 | 6 | 35 |
9 | 8 | 0.08 | 450 | 14.24 | 268 | 1717 | 6.28 / 855.96 | 6 | 60 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 67 | 14.23 | 347 | 331 | 0.33 / 843.91 | 6 | 18 |
2 | 3 | 1033.52 | 2 | 12.84 | 1039 | 27 | 0.36 / 843.94 | 5 | 16 |
3 | 7 | 2004.32 | 105 | 10.28 | 1642 | 1772 | 2.13 / 845.71 | 16 | 30 |
4 | 13 | 1923.48 | 36 | 12.80 | 1634 | 753 | 2.88 / 846.47 | 5 | 43 |
5 | 13 | 1410.24 | 36 | 13.19 | 1310 | 622 | 3.50 / 847.09 | 5 | 50 |
6 | 13 | 1004.96 | 36 | 13.44 | 1038 | 502 | 4.01 / 847.59 | 5 | 55 |
7 | 13 | 569.96 | 36 | 13.78 | 716 | 355 | 4.36 / 847.95 | 5 | 53 |
8 | 8 | 0.12 | 450 | 14.25 | 270 | 1731 | 6.09 / 849.68 | 6 | 60 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 70 | 14.24 | 340 | 339 | 0.34 / 837.63 | 6 | 17 |
2 | 3 | 964.96 | -1 | 14.24 | 340 | 0 | 0.00 / 837.63 | 6 | 17 |
3 | 7 | 2001.56 | 106 | 10.25 | 1659 | 1803 | 2.14 / 839.43 | 17 | 30 |
4 | 13 | 1918.08 | 36 | 12.79 | 1643 | 757 | 2.90 / 840.19 | 5 | 44 |
5 | 13 | 1520.88 | 36 | 13.12 | 1393 | 658 | 3.56 / 840.85 | 5 | 50 |
6 | 13 | 1089.00 | 36 | 13.38 | 1102 | 531 | 4.09 / 841.38 | 5 | 54 |
7 | 13 | 535.04 | 36 | 13.81 | 694 | 345 | 4.43 / 841.72 | 5 | 53 |
8 | 13 | 6.24 | 36 | 14.37 | 281 | 145 | 4.58 / 841.87 | 6 | 41 |
9 | 8 | 0.08 | 450 | 14.24 | 268 | 1717 | 6.29 / 843.58 | 6 | 61 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 70 | 14.25 | 337 | 336 | 0.34 / 831.45 | 6 | 18 |
2 | 7 | 2008.00 | 105 | 10.19 | 1651 | 1766 | 2.10 / 833.22 | 18 | 30 |
3 | 13 | 1934.08 | 36 | 12.79 | 1643 | 757 | 2.86 / 833.97 | 5 | 43 |
4 | 13 | 1519.60 | 36 | 13.13 | 1383 | 654 | 3.51 / 834.63 | 5 | 50 |
5 | 13 | 992.60 | 36 | 13.46 | 1032 | 500 | 4.01 / 835.13 | 5 | 55 |
6 | 13 | 459.72 | 36 | 13.89 | 628 | 314 | 4.33 / 835.44 | 5 | 50 |
7 | 13 | 8.88 | 36 | 14.38 | 278 | 144 | 4.47 / 835.58 | 6 | 41 |
8 | 8 | 0.16 | 450 | 14.25 | 266 | 1706 | 6.18 / 837.29 | 6 | 57 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 69 | 14.22 | 348 | 341 | 0.34 / 825.28 | 6 | 17 |
2 | 3 | 1010.56 | 1 | 12.19 | 1036 | 13 | 0.35 / 825.29 | 5 | 5 |
3 | 7 | 2002.68 | 106 | 10.28 | 1650 | 1798 | 2.15 / 827.09 | 5 | 30 |
4 | 13 | 1906.08 | 36 | 12.77 | 1636 | 752 | 2.90 / 827.84 | 5 | 44 |
5 | 13 | 1589.52 | 36 | 13.07 | 1432 | 674 | 3.58 / 828.52 | 5 | 49 |
6 | 13 | 955.24 | 36 | 13.47 | 1003 | 486 | 4.06 / 829.00 | 5 | 55 |
7 | 13 | 621.92 | 36 | 13.73 | 755 | 373 | 4.44 / 829.37 | 5 | 54 |
8 | 8 | 0.04 | 450 | 14.25 | 271 | 1738 | 6.18 / 831.11 | 6 | 61 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 69 | 14.28 | 337 | 332 | 0.33 / 819.23 | 6 | 17 |
2 | 7 | 2006.72 | 105 | 10.32 | 1649 | 1787 | 2.12 / 821.01 | 17 | 31 |
3 | 13 | 1912.08 | 36 | 12.79 | 1630 | 751 | 2.87 / 821.76 | 5 | 43 |
4 | 13 | 1496.60 | 36 | 13.12 | 1371 | 648 | 3.52 / 822.41 | 5 | 50 |
5 | 13 | 968.32 | 36 | 13.45 | 1004 | 486 | 4.00 / 822.90 | 5 | 55 |
6 | 13 | 426.56 | 36 | 13.93 | 605 | 303 | 4.31 / 823.20 | 5 | 48 |
7 | 8 | 0.24 | 450 | 14.25 | 271 | 1738 | 6.04 / 824.94 | 6 | 62 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 66 | 14.26 | 343 | 323 | 0.32 / 812.98 | 6 | 15 |
2 | 3 | 1061.92 | 3 | 12.87 | 1066 | 41 | 0.36 / 813.02 | 5 | 28 |
3 | 7 | 2009.76 | 106 | 10.43 | 1658 | 1833 | 2.20 / 814.85 | 28 | 31 |
4 | 13 | 1928.40 | 36 | 12.77 | 1642 | 755 | 2.95 / 815.61 | 5 | 43 |
5 | 13 | 1829.56 | 36 | 12.91 | 1585 | 737 | 3.69 / 816.35 | 5 | 46 |
6 | 13 | 917.28 | 36 | 13.50 | 977 | 475 | 4.16 / 816.82 | 5 | 55 |
7 | 13 | 597.88 | 36 | 13.77 | 727 | 360 | 4.52 / 817.18 | 5 | 53 |
8 | 8 | 0.16 | 450 | 14.25 | 267 | 1712 | 6.24 / 818.89 | 6 | 59 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 69 | 14.26 | 332 | 327 | 0.33 / 806.73 | 6 | 14 |
2 | 3 | 961.40 | -1 | 14.26 | 332 | 0 | 0.00 / 806.73 | 6 | 14 |
3 | 7 | 2007.48 | 105 | 10.38 | 1661 | 1810 | 2.14 / 808.54 | 14 | 31 |
4 | 13 | 1916.52 | 36 | 12.75 | 1642 | 754 | 2.89 / 809.29 | 5 | 43 |
5 | 13 | 1604.52 | 36 | 13.05 | 1447 | 680 | 3.57 / 809.97 | 5 | 49 |
6 | 13 | 958.08 | 36 | 13.47 | 1001 | 485 | 4.06 / 810.46 | 5 | 56 |
7 | 13 | 529.20 | 36 | 13.82 | 685 | 341 | 4.40 / 810.80 | 5 | 51 |
8 | 13 | 18.80 | 36 | 14.36 | 289 | 149 | 4.55 / 810.95 | 6 | 40 |
9 | 8 | 0.08 | 450 | 14.26 | 266 | 1707 | 6.25 / 812.66 | 6 | 59 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 69 | 14.30 | 336 | 332 | 0.33 / 800.27 | 6 | 16 |
2 | 7 | 2009.88 | 105 | 10.41 | 1660 | 1814 | 2.15 / 802.09 | 16 | 31 |
3 | 13 | 1924.00 | 36 | 12.74 | 1645 | 754 | 2.90 / 802.84 | 5 | 44 |
4 | 13 | 1622.52 | 36 | 13.04 | 1453 | 682 | 3.58 / 803.52 | 5 | 49 |
5 | 13 | 966.04 | 36 | 13.45 | 1013 | 490 | 4.07 / 804.01 | 5 | 55 |
6 | 13 | 541.48 | 36 | 13.81 | 696 | 346 | 4.42 / 804.36 | 5 | 51 |
7 | 13 | 93.36 | 36 | 14.26 | 351 | 180 | 4.60 / 804.54 | 6 | 42 |
8 | 13 | 22.08 | 36 | 14.35 | 294 | 152 | 4.75 / 804.69 | 6 | 42 |
9 | 8 | 0.08 | 450 | 14.26 | 267 | 1713 | 6.46 / 806.40 | 6 | 51 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 69 | 14.28 | 339 | 334 | 0.33 / 793.87 | 6 | 16 |
2 | 7 | 2013.36 | 105 | 10.47 | 1662 | 1827 | 2.16 / 795.70 | 5 | 31 |
3 | 13 | 1923.92 | 36 | 12.75 | 1640 | 753 | 2.91 / 796.45 | 5 | 44 |
4 | 13 | 1718.64 | 36 | 13.00 | 1515 | 709 | 3.62 / 797.16 | 5 | 48 |
5 | 13 | 1024.56 | 36 | 13.41 | 1045 | 504 | 4.13 / 797.66 | 5 | 55 |
6 | 13 | 693.24 | 36 | 13.67 | 809 | 398 | 4.53 / 798.06 | 5 | 55 |
7 | 13 | 45.52 | 36 | 14.33 | 309 | 159 | 4.68 / 798.22 | 6 | 41 |
8 | 8 | 0.12 | 450 | 14.24 | 268 | 1717 | 6.40 / 799.94 | 6 | 58 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 69 | 14.29 | 335 | 330 | 0.33 / 787.67 | 6 | 15 |
2 | 7 | 2011.52 | 105 | 10.54 | 1665 | 1843 | 2.17 / 789.52 | 15 | 32 |
3 | 13 | 1924.36 | 36 | 12.75 | 1644 | 755 | 2.93 / 790.27 | 5 | 44 |
4 | 13 | 1422.36 | 36 | 13.16 | 1318 | 624 | 3.55 / 790.90 | 5 | 51 |
5 | 13 | 1006.52 | 36 | 13.43 | 1033 | 499 | 4.05 / 791.40 | 5 | 56 |
6 | 13 | 360.44 | 36 | 13.99 | 553 | 279 | 4.33 / 791.67 | 5 | 47 |
7 | 13 | 61.80 | 36 | 14.31 | 319 | 164 | 4.49 / 791.84 | 6 | 41 |
8 | 8 | -0.04 | 450 | 14.25 | 265 | 1699 | 6.19 / 793.54 | 6 | 58 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 69 | 14.29 | 346 | 341 | 0.34 / 781.27 | 6 | 16 |
2 | 7 | 2004.68 | 106 | 10.60 | 1661 | 1866 | 2.21 / 783.13 | 16 | 32 |
3 | 13 | 1913.84 | 36 | 12.74 | 1639 | 752 | 2.96 / 783.88 | 5 | 44 |
4 | 13 | 1706.92 | 36 | 12.97 | 1510 | 705 | 3.66 / 784.59 | 5 | 49 |
5 | 13 | 924.72 | 36 | 13.45 | 984 | 476 | 4.14 / 785.06 | 5 | 56 |
6 | 13 | 701.56 | 36 | 13.65 | 817 | 401 | 4.54 / 785.47 | 5 | 56 |
7 | 13 | 51.44 | 36 | 14.30 | 316 | 163 | 4.70 / 785.63 | 6 | 42 |
8 | 8 | 0.20 | 450 | 14.22 | 268 | 1715 | 6.42 / 787.34 | 6 | 60 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 69 | 14.30 | 331 | 327 | 0.33 / 774.88 | 6 | 14 |
2 | 7 | 2009.12 | 105 | 10.60 | 1659 | 1846 | 2.17 / 776.72 | 14 | 32 |
3 | 13 | 1928.04 | 36 | 12.70 | 1641 | 750 | 2.92 / 777.47 | 5 | 44 |
4 | 13 | 1830.28 | 36 | 12.86 | 1590 | 736 | 3.66 / 778.21 | 5 | 47 |
5 | 13 | 1021.96 | 36 | 13.39 | 1056 | 509 | 4.17 / 778.72 | 5 | 56 |
6 | 13 | 474.84 | 36 | 13.86 | 645 | 322 | 4.49 / 779.04 | 5 | 51 |
7 | 13 | 58.88 | 36 | 14.30 | 324 | 167 | 4.66 / 779.21 | 6 | 42 |
8 | 8 | 0.16 | 450 | 14.23 | 268 | 1716 | 6.37 / 780.92 | 6 | 72 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 69 | 14.29 | 336 | 331 | 0.33 / 768.67 | 6 | 15 |
2 | 7 | 2001.28 | 105 | 10.65 | 1655 | 1851 | 2.18 / 770.52 | 15 | 32 |
3 | 13 | 1913.60 | 36 | 12.71 | 1637 | 749 | 2.93 / 771.27 | 5 | 44 |
4 | 13 | 1405.48 | 36 | 13.13 | 1316 | 622 | 3.55 / 771.89 | 5 | 51 |
5 | 13 | 999.80 | 36 | 13.41 | 1039 | 502 | 4.05 / 772.39 | 5 | 56 |
6 | 13 | 451.68 | 36 | 13.88 | 626 | 313 | 4.37 / 772.70 | 5 | 50 |
7 | 13 | 47.96 | 36 | 14.32 | 310 | 160 | 4.53 / 772.86 | 6 | 41 |
8 | 8 | 0.12 | 450 | 14.25 | 263 | 1686 | 6.21 / 774.55 | 6 | 67 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 69 | 14.31 | 344 | 340 | 0.34 / 762.47 | 6 | 14 |
2 | 7 | 2001.32 | 105 | 10.70 | 1652 | 1856 | 2.20 / 764.33 | 14 | 32 |
3 | 13 | 1913.04 | 36 | 12.73 | 1640 | 752 | 2.95 / 765.08 | 5 | 44 |
4 | 13 | 1387.76 | 36 | 13.14 | 1308 | 619 | 3.57 / 765.70 | 5 | 52 |
5 | 13 | 975.60 | 36 | 13.42 | 1021 | 493 | 4.06 / 766.19 | 5 | 55 |
6 | 13 | 429.64 | 36 | 13.91 | 613 | 307 | 4.37 / 766.50 | 5 | 49 |
7 | 13 | 39.80 | 36 | 14.33 | 306 | 158 | 4.52 / 766.66 | 6 | 41 |
8 | 8 | 0.12 | 450 | 14.25 | 262 | 1680 | 6.20 / 768.34 | 6 | 64 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 69 | 14.28 | 341 | 336 | 0.34 / 756.19 | 6 | 14 |
2 | 7 | 2001.32 | 105 | 10.73 | 1650 | 1859 | 2.19 / 758.05 | 14 | 32 |
3 | 13 | 1908.64 | 36 | 12.69 | 1635 | 747 | 2.94 / 758.79 | 5 | 44 |
4 | 13 | 1596.32 | 36 | 13.02 | 1441 | 675 | 3.62 / 759.47 | 5 | 49 |
5 | 13 | 1026.88 | 36 | 13.37 | 1057 | 509 | 4.13 / 759.98 | 5 | 56 |
6 | 13 | 374.72 | 36 | 13.98 | 567 | 285 | 4.41 / 760.26 | 5 | 47 |
7 | 13 | 40.08 | 36 | 14.33 | 308 | 159 | 4.57 / 760.42 | 6 | 40 |
8 | 8 | -0.04 | 450 | 14.25 | 267 | 1712 | 6.28 / 762.13 | 6 | 57 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 69 | 14.31 | 332 | 328 | 0.33 / 750.07 | 6 | 13 |
2 | 7 | 2002.20 | 106 | 10.76 | 1658 | 1891 | 2.22 / 751.97 | 13 | 32 |
3 | 13 | 1917.24 | 36 | 12.69 | 1646 | 752 | 2.97 / 752.72 | 5 | 44 |
4 | 13 | 1291.72 | 36 | 13.18 | 1239 | 588 | 3.56 / 753.31 | 5 | 52 |
5 | 13 | 787.68 | 36 | 13.55 | 892 | 435 | 3.99 / 753.74 | 5 | 55 |
6 | 13 | 267.64 | 36 | 14.08 | 484 | 245 | 4.24 / 753.99 | 5 | 44 |
7 | 13 | 32.92 | 36 | 14.33 | 305 | 157 | 4.40 / 754.14 | 6 | 41 |
8 | 8 | 0.08 | 450 | 14.21 | 267 | 1707 | 6.10 / 755.85 | 6 | 62 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 69 | 14.30 | 331 | 327 | 0.33 / 743.80 | 6 | 12 |
2 | 7 | 2011.20 | 105 | 10.77 | 1664 | 1882 | 2.21 / 745.68 | 12 | 32 |
3 | 13 | 1808.88 | 36 | 12.79 | 1576 | 726 | 2.93 / 746.41 | 5 | 45 |
4 | 13 | 1606.32 | 36 | 13.01 | 1447 | 678 | 3.61 / 747.08 | 5 | 50 |
5 | 13 | 1057.48 | 36 | 13.35 | 1074 | 516 | 4.13 / 747.60 | 5 | 56 |
6 | 13 | 393.00 | 36 | 13.93 | 578 | 290 | 4.42 / 747.89 | 5 | 49 |
7 | 13 | 43.16 | 36 | 14.31 | 309 | 159 | 4.58 / 748.05 | 6 | 41 |
8 | 8 | 0.20 | 450 | 14.24 | 265 | 1698 | 6.28 / 749.75 | 6 | 55 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 69 | 14.31 | 334 | 330 | 0.33 / 737.43 | 6 | 13 |
2 | 7 | 2004.16 | 105 | 10.84 | 1651 | 1879 | 2.21 / 739.31 | 13 | 33 |
3 | 13 | 1912.88 | 36 | 12.68 | 1639 | 748 | 2.96 / 740.06 | 5 | 44 |
4 | 13 | 1499.16 | 36 | 13.06 | 1386 | 652 | 3.61 / 740.71 | 5 | 51 |
5 | 13 | 961.68 | 36 | 13.41 | 1013 | 489 | 4.10 / 741.20 | 5 | 56 |
6 | 13 | 319.68 | 36 | 14.00 | 527 | 266 | 4.36 / 741.46 | 5 | 46 |
7 | 13 | 42.72 | 36 | 14.32 | 313 | 161 | 4.52 / 741.62 | 6 | 41 |
8 | 13 | 10.32 | 36 | 14.31 | 285 | 147 | 4.67 / 741.77 | 6 | 40 |
9 | 8 | 0.08 | 450 | 14.21 | 266 | 1701 | 6.37 / 743.47 | 6 | 59 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 69 | 14.33 | 333 | 329 | 0.33 / 731.13 | 6 | 12 |
2 | 7 | 2012.32 | 105 | 10.85 | 1668 | 1900 | 2.23 / 733.03 | 12 | 33 |
3 | 13 | 1913.00 | 36 | 12.65 | 1640 | 747 | 2.98 / 733.78 | 5 | 43 |
4 | 13 | 1596.36 | 36 | 12.99 | 1446 | 676 | 3.65 / 734.45 | 5 | 49 |
5 | 13 | 933.52 | 36 | 13.43 | 994 | 481 | 4.13 / 734.93 | 5 | 55 |
6 | 13 | 383.64 | 36 | 13.95 | 578 | 290 | 4.42 / 735.22 | 5 | 48 |
7 | 13 | 34.36 | 36 | 14.33 | 306 | 158 | 4.58 / 735.38 | 6 | 40 |
8 | 8 | 0.04 | 450 | 14.24 | 268 | 1717 | 6.30 / 737.10 | 6 | 56 |
Average= | 6.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 69 | 14.31 | 336 | 332 | 0.33 / 724.78 | 6 | 13 |
2 | 7 | 2010.28 | 105 | 10.88 | 1657 | 1893 | 2.22 / 726.67 | 13 | 33 |
3 | 13 | 1913.68 | 36 | 12.66 | 1640 | 747 | 2.97 / 727.42 | 5 | 43 |
4 | 13 | 1604.88 | 36 | 12.99 | 1448 | 677 | 3.65 / 728.10 | 5 | 49 |
5 | 13 | 861.00 | 36 | 13.49 | 937 | 455 | 4.10 / 728.55 | 5 | 55 |
6 | 13 | 336.52 | 36 | 14.01 | 536 | 270 | 4.37 / 728.82 | 5 | 45 |
7 | 13 | 23.88 | 36 | 14.35 | 294 | 152 | 4.53 / 728.97 | 6 | 40 |
8 | 13 | 11.36 | 36 | 14.26 | 284 | 146 | 4.67 / 729.12 | 6 | 41 |
9 | 8 | 0.04 | 450 | 14.21 | 263 | 1682 | 6.35 / 730.80 | 6 | 62 |
Average= | 6.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 69 | 14.27 | 338 | 333 | 0.33 / 718.41 | 6 | 14 |
2 | 7 | 2005.36 | 105 | 10.92 | 1658 | 1901 | 2.23 / 720.31 | 14 | 33 |
3 | 13 | 1921.96 | 36 | 12.64 | 1640 | 746 | 2.98 / 721.06 | 5 | 42 |
4 | 13 | 1600.04 | 36 | 12.98 | 1443 | 674 | 3.65 / 721.73 | 5 | 48 |
5 | 13 | 936.04 | 36 | 13.43 | 990 | 479 | 4.13 / 722.21 | 5 | 55 |
6 | 13 | 199.84 | 36 | 14.17 | 432 | 220 | 4.35 / 722.43 | 5 | 40 |
7 | 13 | 23.56 | 36 | 14.35 | 298 | 154 | 4.51 / 722.59 | 6 | 38 |
8 | 13 | 10.84 | 36 | 14.28 | 285 | 147 | 4.65 / 722.73 | 6 | 40 |
9 | 8 | 0.04 | 450 | 14.20 | 268 | 1713 | 6.37 / 724.45 | 6 | 62 |
Average= | 6.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 69 | 14.30 | 339 | 334 | 0.33 / 711.99 | 6 | 14 |
2 | 7 | 2003.72 | 105 | 10.96 | 1663 | 1914 | 2.25 / 713.91 | 5 | 32 |
3 | 13 | 1915.92 | 36 | 12.62 | 1638 | 744 | 2.99 / 714.65 | 5 | 43 |
4 | 13 | 1600.72 | 36 | 12.97 | 1448 | 676 | 3.67 / 715.33 | 5 | 48 |
5 | 13 | 950.08 | 36 | 13.39 | 1004 | 484 | 4.15 / 715.81 | 5 | 55 |
6 | 13 | 314.84 | 36 | 14.03 | 521 | 263 | 4.42 / 716.08 | 5 | 43 |
7 | 13 | 19.72 | 36 | 14.36 | 295 | 153 | 4.57 / 716.23 | 6 | 40 |
8 | 13 | 7.44 | 36 | 14.26 | 286 | 147 | 4.71 / 716.37 | 6 | 39 |
9 | 8 | 0.00 | 450 | 14.19 | 267 | 1705 | 6.42 / 718.08 | 6 | 62 |
Average= | 6.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 69 | 14.34 | 336 | 332 | 0.33 / 705.58 | 6 | 15 |
2 | 7 | 2002.24 | 105 | 10.98 | 1663 | 1917 | 2.25 / 707.50 | 5 | 33 |
3 | 13 | 1912.88 | 36 | 12.61 | 1642 | 745 | 3.00 / 708.25 | 5 | 43 |
4 | 13 | 1403.36 | 36 | 13.08 | 1317 | 620 | 3.62 / 708.87 | 5 | 51 |
5 | 13 | 971.96 | 36 | 13.39 | 1018 | 491 | 4.11 / 709.36 | 5 | 55 |
6 | 13 | 314.76 | 36 | 14.03 | 521 | 263 | 4.37 / 709.62 | 5 | 44 |
7 | 13 | 22.96 | 36 | 14.33 | 301 | 155 | 4.52 / 709.78 | 6 | 40 |
8 | 13 | 11.36 | 36 | 14.25 | 290 | 149 | 4.67 / 709.93 | 6 | 41 |
9 | 8 | 0.04 | 450 | 14.17 | 272 | 1734 | 6.41 / 711.66 | 6 | 60 |
Average= | 6.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 68 | 14.31 | 341 | 332 | 0.33 / 699.33 | 6 | 15 |
2 | 3 | 1014.80 | 1 | 11.82 | 1019 | 12 | 0.34 / 699.34 | 5 | 6 |
3 | 7 | 2001.12 | 105 | 11.04 | 1663 | 1928 | 2.27 / 701.27 | 6 | 33 |
4 | 13 | 1909.76 | 36 | 12.62 | 1639 | 745 | 3.02 / 702.01 | 5 | 43 |
5 | 13 | 1499.76 | 36 | 13.01 | 1379 | 646 | 3.66 / 702.66 | 5 | 50 |
6 | 13 | 943.88 | 36 | 13.41 | 999 | 482 | 4.14 / 703.14 | 5 | 54 |
7 | 13 | 307.00 | 36 | 14.05 | 510 | 258 | 4.40 / 703.40 | 5 | 42 |
8 | 13 | 22.80 | 36 | 14.35 | 295 | 152 | 4.55 / 703.55 | 6 | 39 |
9 | 8 | 0.12 | 450 | 14.21 | 266 | 1701 | 6.26 / 705.25 | 6 | 57 |
Average= | 6.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 68 | 14.29 | 341 | 331 | 0.33 / 693.07 | 6 | 16 |
2 | 7 | 2006.16 | 105 | 11.06 | 1671 | 1941 | 2.27 / 695.01 | 16 | 34 |
3 | 13 | 1916.76 | 36 | 12.62 | 1640 | 745 | 3.02 / 695.75 | 5 | 43 |
4 | 13 | 1416.08 | 36 | 13.08 | 1318 | 621 | 3.64 / 696.37 | 5 | 51 |
5 | 13 | 889.28 | 36 | 13.45 | 960 | 465 | 4.10 / 696.84 | 5 | 54 |
6 | 13 | 366.44 | 36 | 13.98 | 557 | 280 | 4.38 / 697.12 | 5 | 45 |
7 | 13 | 15.52 | 36 | 14.35 | 292 | 151 | 4.53 / 697.27 | 6 | 39 |
8 | 8 | 0.00 | 450 | 14.17 | 271 | 1728 | 6.26 / 699.00 | 6 | 64 |
Average= | 6.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 68 | 14.28 | 345 | 335 | 0.34 / 686.74 | 6 | 16 |
2 | 3 | 1011.84 | 1 | 11.71 | 1029 | 12 | 0.35 / 686.75 | 5 | 5 |
3 | 7 | 2007.08 | 105 | 11.16 | 1673 | 1960 | 2.31 / 688.71 | 5 | 34 |
4 | 13 | 1907.32 | 36 | 12.65 | 1630 | 742 | 3.05 / 689.45 | 5 | 43 |
5 | 13 | 1387.00 | 36 | 13.08 | 1304 | 614 | 3.66 / 690.07 | 5 | 51 |
6 | 13 | 954.00 | 36 | 13.39 | 1013 | 488 | 4.15 / 690.56 | 5 | 56 |
7 | 13 | 399.32 | 36 | 13.91 | 585 | 293 | 4.45 / 690.85 | 5 | 48 |
8 | 13 | 31.72 | 36 | 14.32 | 302 | 156 | 4.60 / 691.01 | 6 | 41 |
9 | 8 | 0.08 | 450 | 14.18 | 271 | 1729 | 6.33 / 692.74 | 6 | 63 |
Average= | 6.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 68 | 14.25 | 341 | 330 | 0.33 / 680.52 | 6 | 20 |
2 | 7 | 2002.72 | 106 | 11.16 | 1669 | 1974 | 2.30 / 682.49 | 20 | 35 |
3 | 13 | 1910.12 | 36 | 12.62 | 1636 | 743 | 3.05 / 683.24 | 5 | 44 |
4 | 13 | 1476.68 | 36 | 13.02 | 1370 | 642 | 3.69 / 683.88 | 5 | 51 |
5 | 13 | 830.88 | 36 | 13.47 | 921 | 447 | 4.14 / 684.32 | 5 | 56 |
6 | 13 | 182.72 | 36 | 14.15 | 418 | 213 | 4.35 / 684.54 | 5 | 42 |
7 | 13 | 1.48 | 36 | 14.37 | 283 | 146 | 4.50 / 684.68 | 6 | 41 |
8 | 8 | 0.08 | 450 | 14.17 | 270 | 1722 | 6.22 / 686.41 | 6 | 58 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 67 | 14.26 | 347 | 332 | 0.33 / 674.46 | 6 | 20 |
2 | 7 | 2001.84 | 105 | 11.20 | 1665 | 1958 | 2.29 / 676.42 | 5 | 35 |
3 | 13 | 1907.76 | 36 | 12.62 | 1634 | 742 | 3.03 / 677.16 | 5 | 45 |
4 | 13 | 1390.64 | 36 | 13.07 | 1313 | 618 | 3.65 / 677.78 | 5 | 52 |
5 | 13 | 866.40 | 36 | 13.45 | 943 | 457 | 4.11 / 678.24 | 5 | 56 |
6 | 13 | 225.04 | 36 | 14.12 | 447 | 227 | 4.33 / 678.46 | 5 | 43 |
7 | 8 | 0.08 | 450 | 14.18 | 270 | 1723 | 6.06 / 680.19 | 6 | 61 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 67 | 14.26 | 344 | 329 | 0.33 / 668.25 | 6 | 18 |
2 | 7 | 2012.20 | 105 | 11.16 | 1677 | 1965 | 2.29 / 670.22 | 18 | 34 |
3 | 13 | 1917.40 | 36 | 12.61 | 1643 | 746 | 3.04 / 670.96 | 5 | 44 |
4 | 13 | 1393.12 | 36 | 13.07 | 1309 | 616 | 3.66 / 671.58 | 5 | 51 |
5 | 13 | 1068.52 | 36 | 13.29 | 1093 | 523 | 4.18 / 672.10 | 5 | 55 |
6 | 13 | 395.60 | 36 | 13.90 | 588 | 294 | 4.47 / 672.40 | 5 | 49 |
7 | 8 | 0.20 | 450 | 14.17 | 272 | 1734 | 6.21 / 674.13 | 6 | 61 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 67 | 14.28 | 341 | 326 | 0.33 / 662.01 | 6 | 18 |
2 | 7 | 2010.40 | 105 | 11.26 | 1666 | 1970 | 2.30 / 663.98 | 5 | 35 |
3 | 13 | 1816.20 | 36 | 12.72 | 1579 | 723 | 3.02 / 664.71 | 5 | 45 |
4 | 13 | 1398.88 | 36 | 13.07 | 1312 | 617 | 3.64 / 665.32 | 5 | 52 |
5 | 13 | 968.32 | 36 | 13.36 | 1018 | 490 | 4.13 / 665.81 | 5 | 56 |
6 | 13 | 219.80 | 36 | 14.12 | 448 | 228 | 4.35 / 666.04 | 5 | 42 |
7 | 13 | 19.48 | 36 | 14.33 | 296 | 153 | 4.51 / 666.19 | 6 | 42 |
8 | 8 | 0.04 | 450 | 14.14 | 272 | 1731 | 6.24 / 667.92 | 6 | 57 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 65 | 14.23 | 355 | 328 | 0.33 / 655.78 | 6 | 20 |
2 | 3 | 1038.28 | 2 | 12.76 | 1044 | 27 | 0.36 / 655.80 | 5 | 19 |
3 | 7 | 2009.92 | 105 | 11.30 | 1674 | 1986 | 2.34 / 657.79 | 19 | 35 |
4 | 13 | 1918.84 | 36 | 12.62 | 1639 | 745 | 3.09 / 658.54 | 5 | 43 |
5 | 13 | 1486.68 | 36 | 13.02 | 1371 | 643 | 3.73 / 659.18 | 5 | 50 |
6 | 13 | 954.68 | 36 | 13.38 | 1012 | 487 | 4.22 / 659.67 | 5 | 56 |
7 | 13 | 400.76 | 36 | 13.90 | 589 | 295 | 4.51 / 659.96 | 5 | 49 |
8 | 8 | 0.00 | 450 | 14.16 | 271 | 1727 | 6.24 / 661.69 | 6 | 61 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 68 | 14.29 | 344 | 334 | 0.33 / 649.54 | 6 | 20 |
2 | 3 | 964.12 | -1 | 14.29 | 344 | 0 | 0.00 / 649.54 | 6 | 20 |
3 | 7 | 2008.08 | 105 | 11.26 | 1676 | 1982 | 2.32 / 651.52 | 20 | 35 |
4 | 13 | 1912.32 | 36 | 12.61 | 1636 | 743 | 3.06 / 652.26 | 5 | 43 |
5 | 13 | 1393.56 | 36 | 13.07 | 1311 | 617 | 3.68 / 652.88 | 5 | 52 |
6 | 13 | 967.92 | 36 | 13.37 | 1019 | 490 | 4.17 / 653.37 | 5 | 55 |
7 | 13 | 525.68 | 36 | 13.77 | 688 | 341 | 4.51 / 653.71 | 5 | 53 |
8 | 8 | 0.24 | 450 | 14.16 | 273 | 1740 | 6.25 / 655.45 | 6 | 62 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 68 | 14.26 | 355 | 344 | 0.34 / 643.30 | 6 | 22 |
2 | 7 | 2006.72 | 105 | 11.33 | 1673 | 1990 | 2.33 / 645.29 | 22 | 35 |
3 | 13 | 1924.32 | 36 | 12.62 | 1648 | 749 | 3.08 / 646.04 | 5 | 44 |
4 | 13 | 1392.64 | 36 | 13.06 | 1312 | 617 | 3.70 / 646.65 | 5 | 52 |
5 | 13 | 845.20 | 36 | 13.47 | 931 | 451 | 4.15 / 647.11 | 5 | 56 |
6 | 13 | 210.52 | 36 | 14.15 | 437 | 223 | 4.37 / 647.33 | 5 | 42 |
7 | 13 | 2.88 | 36 | 14.37 | 286 | 148 | 4.52 / 647.48 | 5 | 41 |
8 | 8 | 0.08 | 450 | 14.16 | 271 | 1727 | 6.25 / 649.20 | 6 | 57 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 67 | 14.26 | 356 | 340 | 0.34 / 636.97 | 6 | 20 |
2 | 3 | 1031.76 | 2 | 12.74 | 1031 | 26 | 0.37 / 637.00 | 5 | 16 |
3 | 7 | 2011.48 | 106 | 11.29 | 1683 | 2014 | 2.38 / 639.01 | 16 | 36 |
4 | 13 | 1914.44 | 36 | 12.64 | 1645 | 749 | 3.13 / 639.76 | 5 | 43 |
5 | 13 | 1486.48 | 36 | 13.02 | 1374 | 644 | 3.77 / 640.40 | 5 | 51 |
6 | 13 | 1053.00 | 36 | 13.32 | 1083 | 519 | 4.29 / 640.92 | 5 | 56 |
7 | 13 | 376.64 | 36 | 13.94 | 572 | 287 | 4.58 / 641.21 | 5 | 49 |
8 | 8 | 0.08 | 450 | 14.15 | 274 | 1745 | 6.32 / 642.95 | 6 | 55 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 66 | 14.25 | 348 | 327 | 0.33 / 630.86 | 6 | 21 |
2 | 7 | 2002.64 | 105 | 11.40 | 1671 | 2000 | 2.33 / 632.86 | 5 | 35 |
3 | 13 | 1909.68 | 36 | 12.65 | 1637 | 745 | 3.07 / 633.61 | 5 | 43 |
4 | 13 | 1283.32 | 36 | 13.16 | 1235 | 585 | 3.66 / 634.19 | 5 | 52 |
5 | 13 | 872.24 | 36 | 13.47 | 948 | 460 | 4.12 / 634.65 | 5 | 54 |
6 | 13 | 232.80 | 36 | 14.13 | 460 | 234 | 4.35 / 634.89 | 5 | 41 |
7 | 8 | 0.12 | 450 | 14.19 | 273 | 1743 | 6.10 / 636.63 | 6 | 57 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 65 | 14.27 | 358 | 332 | 0.33 / 624.62 | 6 | 22 |
2 | 3 | 1030.52 | 2 | 12.88 | 1030 | 27 | 0.36 / 624.64 | 5 | 17 |
3 | 7 | 2010.32 | 105 | 11.43 | 1669 | 2003 | 2.36 / 626.65 | 17 | 36 |
4 | 13 | 1914.20 | 36 | 12.64 | 1636 | 744 | 3.11 / 627.39 | 5 | 43 |
5 | 13 | 1492.76 | 36 | 13.02 | 1378 | 646 | 3.75 / 628.04 | 5 | 50 |
6 | 13 | 922.00 | 36 | 13.43 | 985 | 476 | 4.23 / 628.51 | 5 | 56 |
7 | 13 | 378.96 | 36 | 13.94 | 574 | 288 | 4.52 / 628.80 | 5 | 48 |
8 | 8 | 0.08 | 450 | 14.16 | 272 | 1733 | 6.25 / 630.53 | 6 | 64 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 68 | 14.23 | 359 | 347 | 0.35 / 618.47 | 6 | 21 |
2 | 3 | 962.00 | -1 | 14.23 | 359 | 0 | 0.00 / 618.47 | 6 | 21 |
3 | 7 | 2003.04 | 105 | 11.37 | 1684 | 2010 | 2.36 / 620.48 | 21 | 35 |
4 | 13 | 1905.20 | 36 | 12.63 | 1635 | 743 | 3.10 / 621.23 | 5 | 43 |
5 | 13 | 1366.80 | 36 | 13.09 | 1297 | 611 | 3.71 / 621.84 | 5 | 51 |
6 | 13 | 852.76 | 36 | 13.47 | 942 | 457 | 4.17 / 622.29 | 5 | 55 |
7 | 13 | 223.28 | 36 | 14.13 | 457 | 232 | 4.40 / 622.53 | 5 | 43 |
8 | 8 | 0.16 | 450 | 14.16 | 276 | 1759 | 6.16 / 624.29 | 6 | 62 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 68 | 14.25 | 358 | 347 | 0.35 / 611.89 | 6 | 21 |
2 | 7 | 2009.04 | 105 | 11.35 | 1680 | 2002 | 2.35 / 613.89 | 21 | 35 |
3 | 13 | 1914.04 | 36 | 12.63 | 1642 | 747 | 3.10 / 614.64 | 5 | 42 |
4 | 13 | 1398.80 | 36 | 13.07 | 1319 | 621 | 3.72 / 615.26 | 5 | 51 |
5 | 13 | 971.28 | 36 | 13.39 | 1027 | 495 | 4.21 / 615.75 | 5 | 55 |
6 | 13 | 412.56 | 36 | 13.92 | 602 | 302 | 4.51 / 616.06 | 5 | 48 |
7 | 13 | 12.20 | 36 | 14.36 | 298 | 154 | 4.67 / 616.21 | 6 | 40 |
8 | 13 | 2.32 | 36 | 14.25 | 291 | 149 | 4.82 / 616.36 | 6 | 44 |
9 | 8 | 0.00 | 450 | 14.12 | 278 | 1766 | 6.58 / 618.12 | 6 | 76 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 68 | 14.28 | 353 | 343 | 0.34 / 605.66 | 6 | 21 |
2 | 7 | 2004.36 | 105 | 11.40 | 1681 | 2012 | 2.35 / 607.67 | 5 | 36 |
3 | 13 | 1909.12 | 36 | 12.63 | 1648 | 749 | 3.10 / 608.42 | 5 | 43 |
4 | 13 | 1495.12 | 36 | 13.03 | 1384 | 649 | 3.75 / 609.07 | 5 | 50 |
5 | 13 | 840.12 | 36 | 13.50 | 931 | 452 | 4.21 / 609.52 | 5 | 54 |
6 | 13 | 316.32 | 36 | 14.05 | 521 | 264 | 4.47 / 609.78 | 5 | 45 |
7 | 8 | 0.12 | 450 | 14.17 | 276 | 1760 | 6.23 / 611.54 | 6 | 56 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 66 | 14.28 | 358 | 337 | 0.34 / 599.53 | 6 | 20 |
2 | 3 | 1033.48 | 2 | 12.84 | 1035 | 27 | 0.36 / 599.55 | 5 | 20 |
3 | 7 | 2002.40 | 106 | 11.44 | 1676 | 2032 | 2.40 / 601.59 | 20 | 35 |
4 | 13 | 1808.56 | 36 | 12.75 | 1581 | 726 | 3.12 / 602.31 | 5 | 44 |
5 | 13 | 1273.76 | 36 | 13.18 | 1234 | 586 | 3.71 / 602.90 | 5 | 51 |
6 | 13 | 858.68 | 36 | 13.50 | 944 | 459 | 4.17 / 603.36 | 5 | 54 |
7 | 13 | 124.76 | 36 | 14.26 | 380 | 195 | 4.36 / 603.55 | 5 | 40 |
8 | 8 | 0.12 | 450 | 14.19 | 276 | 1762 | 6.12 / 605.31 | 6 | 57 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 66 | 14.27 | 352 | 332 | 0.33 / 593.24 | 6 | 20 |
2 | 7 | 2003.52 | 105 | 11.49 | 1683 | 2030 | 2.36 / 595.27 | 5 | 35 |
3 | 13 | 1912.40 | 36 | 12.67 | 1645 | 750 | 3.11 / 596.02 | 5 | 42 |
4 | 13 | 1392.12 | 36 | 13.11 | 1315 | 621 | 3.73 / 596.64 | 5 | 50 |
5 | 13 | 955.64 | 36 | 13.43 | 1015 | 491 | 4.22 / 597.13 | 5 | 54 |
6 | 13 | 404.20 | 36 | 13.95 | 593 | 298 | 4.52 / 597.43 | 5 | 47 |
7 | 8 | 0.08 | 450 | 14.17 | 276 | 1760 | 6.28 / 599.19 | 6 | 64 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 66 | 14.29 | 355 | 335 | 0.33 / 587.01 | 6 | 19 |
2 | 7 | 2002.36 | 105 | 11.56 | 1680 | 2039 | 2.37 / 589.05 | 19 | 36 |
3 | 13 | 1904.36 | 36 | 12.69 | 1642 | 750 | 3.12 / 589.80 | 5 | 43 |
4 | 13 | 1370.40 | 36 | 13.12 | 1306 | 617 | 3.74 / 590.42 | 5 | 51 |
5 | 13 | 743.16 | 36 | 13.60 | 864 | 423 | 4.16 / 590.84 | 5 | 54 |
6 | 13 | 420.28 | 36 | 13.92 | 609 | 305 | 4.47 / 591.15 | 5 | 49 |
7 | 8 | 0.20 | 450 | 14.17 | 276 | 1760 | 6.23 / 592.91 | 6 | 55 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 69 | 14.29 | 343 | 338 | 0.34 / 580.63 | 6 | 20 |
2 | 3 | 931.04 | -1 | 14.29 | 343 | 0 | 0.00 / 580.63 | 6 | 20 |
3 | 7 | 2008.20 | 105 | 11.55 | 1684 | 2042 | 2.38 / 582.67 | 20 | 37 |
4 | 13 | 1815.92 | 36 | 12.79 | 1588 | 731 | 3.11 / 583.40 | 5 | 45 |
5 | 13 | 1613.04 | 36 | 12.95 | 1468 | 684 | 3.80 / 584.08 | 5 | 50 |
6 | 13 | 926.72 | 36 | 13.42 | 1004 | 485 | 4.28 / 584.57 | 5 | 56 |
7 | 13 | 382.64 | 36 | 13.92 | 596 | 299 | 4.58 / 584.87 | 5 | 51 |
8 | 8 | 0.20 | 450 | 14.12 | 285 | 1811 | 6.39 / 586.68 | 6 | 61 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 67 | 14.32 | 345 | 331 | 0.33 / 574.35 | 6 | 18 |
2 | 10 | 1005.72 | 6 | 13.51 | 1052 | 85 | 0.42 / 574.44 | 5 | 38 |
3 | 3 | 915.28 | -1 | 13.51 | 1052 | 0 | 0.09 / 574.44 | 5 | 38 |
4 | 7 | 2007.52 | 105 | 11.55 | 1672 | 2028 | 2.44 / 576.46 | 38 | 38 |
5 | 13 | 1911.36 | 36 | 12.68 | 1638 | 748 | 3.19 / 577.21 | 5 | 45 |
6 | 13 | 1375.52 | 36 | 13.12 | 1304 | 616 | 3.81 / 577.83 | 5 | 53 |
7 | 13 | 744.36 | 36 | 13.59 | 869 | 425 | 4.23 / 578.25 | 5 | 57 |
8 | 13 | 309.84 | 36 | 14.01 | 530 | 267 | 4.50 / 578.52 | 5 | 51 |
9 | 8 | 0.12 | 450 | 14.13 | 278 | 1768 | 6.27 / 580.29 | 6 | 65 |
Average= | 6.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 66 | 14.33 | 352 | 333 | 0.33 / 567.81 | 6 | 18 |
2 | 3 | 1017.68 | 1 | 12.56 | 1039 | 13 | 0.35 / 567.82 | 5 | 9 |
3 | 7 | 2003.04 | 105 | 11.58 | 1674 | 2035 | 2.38 / 569.85 | 9 | 37 |
4 | 13 | 1906.24 | 36 | 12.66 | 1640 | 747 | 3.13 / 570.60 | 5 | 44 |
5 | 13 | 1581.80 | 36 | 12.96 | 1445 | 674 | 3.80 / 571.28 | 5 | 50 |
6 | 13 | 1015.44 | 36 | 13.36 | 1066 | 513 | 4.32 / 571.79 | 5 | 57 |
7 | 13 | 357.28 | 36 | 13.94 | 570 | 286 | 4.60 / 572.07 | 5 | 52 |
8 | 13 | 61.12 | 36 | 14.29 | 333 | 171 | 4.77 / 572.25 | 6 | 46 |
9 | 8 | 0.12 | 450 | 14.13 | 279 | 1774 | 6.55 / 574.02 | 6 | 67 |
Average= | 6.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 69 | 14.36 | 342 | 339 | 0.34 / 561.57 | 6 | 17 |
2 | 3 | 960.68 | -1 | 14.36 | 342 | 0 | 0.00 / 561.57 | 6 | 17 |
3 | 7 | 2001.60 | 105 | 11.50 | 1681 | 2030 | 2.37 / 563.60 | 17 | 37 |
4 | 13 | 1912.40 | 36 | 12.61 | 1653 | 750 | 3.12 / 564.35 | 5 | 44 |
5 | 13 | 1470.76 | 36 | 13.02 | 1374 | 644 | 3.76 / 564.99 | 5 | 51 |
6 | 13 | 809.24 | 36 | 13.51 | 919 | 447 | 4.21 / 565.44 | 5 | 57 |
7 | 13 | 280.56 | 36 | 14.05 | 507 | 256 | 4.47 / 565.70 | 5 | 49 |
8 | 8 | 0.12 | 450 | 14.14 | 279 | 1775 | 6.24 / 567.47 | 6 | 65 |
Average= | 6.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 69 | 14.35 | 349 | 346 | 0.35 / 555.27 | 6 | 16 |
2 | 7 | 2003.16 | 105 | 11.38 | 1683 | 2011 | 2.36 / 557.28 | 16 | 36 |
3 | 13 | 1903.72 | 36 | 12.62 | 1645 | 747 | 3.10 / 558.02 | 5 | 43 |
4 | 13 | 1371.52 | 36 | 13.09 | 1310 | 617 | 3.72 / 558.64 | 5 | 52 |
5 | 13 | 835.72 | 36 | 13.51 | 938 | 456 | 4.18 / 559.10 | 5 | 56 |
6 | 13 | 102.00 | 36 | 14.27 | 371 | 191 | 4.37 / 559.29 | 5 | 43 |
7 | 13 | 52.04 | 36 | 14.29 | 329 | 169 | 4.54 / 559.46 | 6 | 43 |
8 | 8 | 0.08 | 450 | 14.18 | 278 | 1774 | 6.31 / 561.23 | 6 | 60 |
Average= | 6.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 69 | 14.36 | 350 | 347 | 0.35 / 548.90 | 6 | 16 |
2 | 7 | 2003.56 | 105 | 11.44 | 1674 | 2011 | 2.36 / 550.91 | 16 | 35 |
3 | 13 | 1795.24 | 36 | 12.76 | 1579 | 725 | 3.08 / 551.64 | 5 | 44 |
4 | 13 | 1371.52 | 36 | 13.12 | 1307 | 617 | 3.70 / 552.25 | 5 | 51 |
5 | 13 | 848.00 | 36 | 13.52 | 944 | 459 | 4.16 / 552.71 | 5 | 55 |
6 | 13 | 314.96 | 36 | 14.08 | 527 | 267 | 4.43 / 552.98 | 5 | 46 |
7 | 13 | 4.76 | 36 | 14.41 | 286 | 148 | 4.58 / 553.13 | 6 | 44 |
8 | 8 | 0.08 | 450 | 14.16 | 281 | 1791 | 6.37 / 554.92 | 6 | 60 |
Average= | 6.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 69 | 14.36 | 347 | 344 | 0.34 / 542.54 | 6 | 16 |
2 | 7 | 2013.04 | 105 | 11.45 | 1677 | 2016 | 2.36 / 544.56 | 16 | 35 |
3 | 13 | 1921.96 | 36 | 12.62 | 1651 | 750 | 3.11 / 545.31 | 5 | 43 |
4 | 13 | 1392.04 | 36 | 13.13 | 1313 | 621 | 3.73 / 545.93 | 5 | 50 |
5 | 13 | 955.76 | 36 | 13.45 | 1016 | 492 | 4.22 / 546.42 | 5 | 55 |
6 | 13 | 210.32 | 36 | 14.21 | 446 | 228 | 4.45 / 546.65 | 5 | 42 |
7 | 13 | 21.76 | 36 | 14.39 | 300 | 155 | 4.61 / 546.80 | 6 | 40 |
8 | 8 | 0.16 | 450 | 14.19 | 274 | 1750 | 6.36 / 548.55 | 6 | 58 |
Average= | 6.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 69 | 14.38 | 341 | 338 | 0.34 / 536.18 | 6 | 16 |
2 | 7 | 2008.40 | 105 | 11.53 | 1678 | 2031 | 2.37 / 538.21 | 16 | 35 |
3 | 13 | 1812.20 | 36 | 12.78 | 1583 | 728 | 3.10 / 538.94 | 5 | 44 |
4 | 13 | 1196.28 | 36 | 13.26 | 1184 | 565 | 3.66 / 539.51 | 5 | 52 |
5 | 13 | 787.44 | 36 | 13.60 | 897 | 439 | 4.10 / 539.95 | 5 | 55 |
6 | 13 | 460.72 | 36 | 13.92 | 639 | 320 | 4.42 / 540.27 | 5 | 50 |
7 | 13 | 5.20 | 36 | 14.39 | 289 | 150 | 4.57 / 540.42 | 6 | 41 |
8 | 8 | 0.12 | 450 | 14.15 | 280 | 1783 | 6.36 / 542.20 | 6 | 59 |
Average= | 6.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 69 | 14.38 | 346 | 343 | 0.34 / 530.00 | 6 | 15 |
2 | 7 | 2009.08 | 105 | 11.48 | 1682 | 2027 | 2.37 / 532.02 | 15 | 35 |
3 | 13 | 1916.72 | 36 | 12.68 | 1648 | 752 | 3.12 / 532.78 | 5 | 43 |
4 | 13 | 1288.24 | 36 | 13.20 | 1249 | 594 | 3.72 / 533.37 | 5 | 52 |
5 | 13 | 775.16 | 36 | 13.61 | 886 | 434 | 4.15 / 533.80 | 5 | 55 |
6 | 13 | 345.96 | 36 | 14.06 | 549 | 278 | 4.43 / 534.08 | 5 | 47 |
7 | 8 | 0.24 | 450 | 14.19 | 276 | 1762 | 6.19 / 535.84 | 6 | 57 |
Average= | 6.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 69 | 14.45 | 347 | 346 | 0.35 / 523.58 | 6 | 14 |
2 | 7 | 2013.52 | 106 | 11.46 | 1674 | 2034 | 2.38 / 525.62 | 14 | 35 |
3 | 13 | 1922.56 | 36 | 12.63 | 1653 | 752 | 3.13 / 526.37 | 5 | 43 |
4 | 13 | 1399.24 | 36 | 13.14 | 1322 | 625 | 3.76 / 526.99 | 5 | 50 |
5 | 13 | 749.04 | 36 | 13.64 | 867 | 426 | 4.18 / 527.42 | 5 | 55 |
6 | 13 | 429.76 | 36 | 13.96 | 617 | 310 | 4.49 / 527.73 | 5 | 50 |
7 | 13 | 42.44 | 36 | 14.37 | 314 | 162 | 4.65 / 527.89 | 6 | 41 |
8 | 8 | 0.24 | 450 | 14.18 | 276 | 1761 | 6.42 / 529.65 | 6 | 56 |
Average= | 6.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 69 | 14.40 | 349 | 347 | 0.35 / 517.22 | 6 | 13 |
2 | 7 | 2009.16 | 105 | 11.54 | 1680 | 2036 | 2.38 / 519.26 | 13 | 35 |
3 | 13 | 1909.12 | 36 | 12.70 | 1641 | 750 | 3.13 / 520.01 | 5 | 43 |
4 | 13 | 1363.52 | 36 | 13.18 | 1302 | 618 | 3.75 / 520.63 | 5 | 51 |
5 | 13 | 833.60 | 36 | 13.58 | 932 | 456 | 4.21 / 521.08 | 5 | 55 |
6 | 13 | 304.36 | 36 | 14.12 | 523 | 266 | 4.47 / 521.35 | 5 | 46 |
7 | 13 | 22.20 | 36 | 14.41 | 297 | 154 | 4.63 / 521.50 | 6 | 40 |
8 | 8 | 0.08 | 450 | 14.21 | 271 | 1733 | 6.36 / 523.24 | 6 | 56 |
Average= | 6.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 69 | 14.43 | 346 | 345 | 0.34 / 510.88 | 6 | 14 |
2 | 7 | 2003.28 | 105 | 11.49 | 1676 | 2022 | 2.37 / 512.90 | 14 | 35 |
3 | 13 | 1911.20 | 36 | 12.70 | 1645 | 752 | 3.12 / 513.65 | 5 | 43 |
4 | 13 | 1280.52 | 36 | 13.25 | 1241 | 592 | 3.71 / 514.24 | 5 | 51 |
5 | 13 | 959.40 | 36 | 13.51 | 1023 | 498 | 4.21 / 514.74 | 5 | 55 |
6 | 13 | 210.76 | 36 | 14.23 | 446 | 228 | 4.44 / 514.97 | 5 | 43 |
7 | 13 | 26.60 | 36 | 14.41 | 304 | 158 | 4.59 / 515.13 | 6 | 41 |
8 | 8 | -0.04 | 450 | 14.19 | 274 | 1750 | 6.34 / 516.88 | 6 | 61 |
Average= | 6.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 69 | 14.43 | 344 | 343 | 0.34 / 504.39 | 6 | 14 |
2 | 7 | 2012.40 | 105 | 11.57 | 1674 | 2034 | 2.38 / 506.43 | 5 | 35 |
3 | 13 | 1815.64 | 36 | 12.84 | 1582 | 731 | 3.11 / 507.16 | 5 | 44 |
4 | 13 | 1609.72 | 36 | 13.06 | 1464 | 688 | 3.80 / 507.85 | 5 | 48 |
5 | 13 | 938.60 | 36 | 13.52 | 1005 | 489 | 4.28 / 508.33 | 5 | 55 |
6 | 13 | 290.08 | 36 | 14.15 | 513 | 261 | 4.55 / 508.60 | 5 | 45 |
7 | 13 | 37.88 | 36 | 14.41 | 313 | 162 | 4.71 / 508.76 | 6 | 40 |
8 | 8 | -0.04 | 450 | 14.19 | 278 | 1775 | 6.48 / 510.53 | 6 | 56 |
Average= | 6.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 69 | 14.43 | 343 | 342 | 0.34 / 497.96 | 6 | 14 |
2 | 7 | 2012.40 | 106 | 11.55 | 1685 | 2063 | 2.40 / 500.02 | 14 | 35 |
3 | 13 | 1918.68 | 36 | 12.76 | 1645 | 756 | 3.16 / 500.77 | 5 | 43 |
4 | 13 | 1280.72 | 36 | 13.29 | 1248 | 597 | 3.76 / 501.37 | 5 | 52 |
5 | 13 | 767.60 | 36 | 13.69 | 884 | 436 | 4.19 / 501.81 | 5 | 55 |
6 | 13 | 439.80 | 36 | 14.00 | 625 | 315 | 4.51 / 502.12 | 5 | 49 |
7 | 13 | 37.84 | 36 | 14.41 | 313 | 162 | 4.67 / 502.28 | 6 | 41 |
8 | 8 | 0.16 | 450 | 14.21 | 276 | 1765 | 6.44 / 504.05 | 6 | 60 |
Average= | 6.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 68 | 14.42 | 343 | 336 | 0.34 / 491.59 | 6 | 14 |
2 | 7 | 2002.16 | 105 | 11.58 | 1668 | 2028 | 2.36 / 493.62 | 5 | 35 |
3 | 13 | 1914.48 | 36 | 12.73 | 1644 | 753 | 3.12 / 494.37 | 5 | 43 |
4 | 13 | 1394.64 | 36 | 13.22 | 1321 | 629 | 3.75 / 495.00 | 5 | 51 |
5 | 13 | 867.68 | 36 | 13.60 | 956 | 468 | 4.21 / 495.47 | 5 | 55 |
6 | 13 | 234.36 | 36 | 14.23 | 463 | 237 | 4.45 / 495.71 | 5 | 43 |
7 | 13 | 17.52 | 36 | 14.43 | 297 | 154 | 4.61 / 495.86 | 6 | 40 |
8 | 8 | 0.12 | 450 | 14.21 | 274 | 1752 | 6.36 / 497.61 | 6 | 55 |
Average= | 6.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 68 | 14.42 | 350 | 343 | 0.34 / 485.06 | 6 | 15 |
2 | 7 | 2003.96 | 105 | 11.61 | 1675 | 2042 | 2.39 / 487.10 | 5 | 36 |
3 | 13 | 1909.56 | 36 | 12.77 | 1640 | 754 | 3.14 / 487.86 | 5 | 43 |
4 | 13 | 1495.16 | 36 | 13.16 | 1387 | 657 | 3.80 / 488.51 | 5 | 50 |
5 | 13 | 947.28 | 36 | 13.54 | 1017 | 496 | 4.29 / 489.01 | 5 | 56 |
6 | 13 | 494.44 | 36 | 13.95 | 667 | 335 | 4.63 / 489.34 | 5 | 51 |
7 | 13 | 28.56 | 36 | 14.41 | 304 | 158 | 4.78 / 489.50 | 6 | 42 |
8 | 8 | -0.20 | 450 | 14.18 | 275 | 1755 | 6.54 / 491.26 | 7 | 56 |
Average= | 6.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 67 | 14.40 | 350 | 338 | 0.34 / 478.70 | 6 | 15 |
2 | 7 | 2003.08 | 105 | 11.59 | 1668 | 2030 | 2.37 / 480.73 | 5 | 35 |
3 | 13 | 1906.32 | 36 | 12.77 | 1640 | 754 | 3.12 / 481.48 | 5 | 43 |
4 | 13 | 1354.08 | 36 | 13.26 | 1293 | 617 | 3.74 / 482.10 | 5 | 52 |
5 | 13 | 817.36 | 36 | 13.66 | 915 | 450 | 4.19 / 482.55 | 5 | 56 |
6 | 13 | 278.52 | 36 | 14.19 | 498 | 254 | 4.44 / 482.80 | 5 | 45 |
7 | 13 | 34.24 | 36 | 14.41 | 308 | 160 | 4.60 / 482.96 | 6 | 41 |
8 | 8 | 0.00 | 450 | 14.19 | 275 | 1756 | 6.36 / 484.72 | 6 | 60 |
Average= | 6.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 67 | 14.41 | 352 | 340 | 0.34 / 472.25 | 6 | 15 |
2 | 7 | 2001.44 | 105 | 11.59 | 1666 | 2027 | 2.37 / 474.28 | 5 | 36 |
3 | 13 | 1901.92 | 36 | 12.81 | 1632 | 753 | 3.12 / 475.03 | 5 | 44 |
4 | 13 | 1592.64 | 36 | 13.14 | 1446 | 684 | 3.80 / 475.71 | 5 | 50 |
5 | 13 | 821.72 | 36 | 13.65 | 928 | 456 | 4.26 / 476.17 | 5 | 56 |
6 | 13 | 277.44 | 36 | 14.18 | 498 | 254 | 4.51 / 476.42 | 5 | 45 |
7 | 13 | 31.80 | 36 | 14.40 | 312 | 162 | 4.68 / 476.58 | 6 | 42 |
8 | 8 | 0.12 | 450 | 14.18 | 278 | 1774 | 6.45 / 478.36 | 6 | 62 |
Average= | 6.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 67 | 14.40 | 350 | 338 | 0.34 / 465.86 | 6 | 15 |
2 | 7 | 2005.44 | 105 | 11.71 | 1669 | 2052 | 2.39 / 467.91 | 5 | 37 |
3 | 13 | 1811.80 | 36 | 12.95 | 1587 | 740 | 3.13 / 468.65 | 5 | 46 |
4 | 13 | 1505.08 | 36 | 13.22 | 1391 | 662 | 3.79 / 469.31 | 5 | 51 |
5 | 13 | 723.56 | 36 | 13.75 | 853 | 422 | 4.21 / 469.73 | 5 | 56 |
6 | 13 | 189.64 | 36 | 14.27 | 433 | 222 | 4.44 / 469.96 | 5 | 43 |
7 | 13 | 16.36 | 36 | 14.42 | 305 | 158 | 4.59 / 470.12 | 6 | 41 |
8 | 8 | 0.16 | 450 | 14.18 | 281 | 1793 | 6.39 / 471.91 | 6 | 62 |
Average= | 6.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 67 | 14.40 | 352 | 340 | 0.34 / 459.34 | 6 | 17 |
2 | 7 | 2010.20 | 106 | 11.69 | 1681 | 2083 | 2.42 / 461.42 | 17 | 37 |
3 | 13 | 1909.96 | 36 | 12.83 | 1643 | 759 | 3.18 / 462.18 | 5 | 44 |
4 | 13 | 1480.08 | 36 | 13.22 | 1380 | 657 | 3.84 / 462.84 | 5 | 51 |
5 | 13 | 841.48 | 36 | 13.65 | 947 | 465 | 4.30 / 463.31 | 5 | 56 |
6 | 13 | 300.72 | 36 | 14.17 | 523 | 267 | 4.57 / 463.57 | 5 | 47 |
7 | 13 | 18.44 | 36 | 14.41 | 302 | 157 | 4.73 / 463.73 | 6 | 42 |
8 | 8 | 0.04 | 450 | 14.17 | 281 | 1792 | 6.52 / 465.52 | 6 | 61 |
Average= | 6.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 67 | 14.40 | 350 | 338 | 0.34 / 452.87 | 6 | 19 |
2 | 7 | 2001.04 | 105 | 11.77 | 1669 | 2063 | 2.40 / 454.93 | 19 | 37 |
3 | 13 | 1901.32 | 36 | 12.84 | 1642 | 759 | 3.16 / 455.69 | 5 | 45 |
4 | 13 | 1371.04 | 36 | 13.29 | 1305 | 624 | 3.78 / 456.32 | 5 | 53 |
5 | 13 | 820.80 | 36 | 13.67 | 930 | 458 | 4.24 / 456.78 | 5 | 58 |
6 | 13 | 282.60 | 36 | 14.15 | 513 | 261 | 4.50 / 457.04 | 5 | 49 |
7 | 13 | 1.72 | 36 | 14.42 | 295 | 153 | 4.66 / 457.19 | 6 | 44 |
8 | 8 | 0.00 | 450 | 14.13 | 285 | 1812 | 6.47 / 459.00 | 6 | 62 |
Average= | 6.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 67 | 14.40 | 357 | 344 | 0.34 / 446.53 | 6 | 18 |
2 | 7 | 2002.36 | 105 | 11.72 | 1672 | 2058 | 2.40 / 448.58 | 18 | 37 |
3 | 13 | 1904.76 | 36 | 12.85 | 1645 | 761 | 3.16 / 449.34 | 5 | 44 |
4 | 13 | 1342.48 | 36 | 13.31 | 1290 | 618 | 3.78 / 449.96 | 5 | 53 |
5 | 13 | 796.00 | 36 | 13.69 | 917 | 452 | 4.23 / 450.41 | 5 | 58 |
6 | 13 | 452.68 | 36 | 13.97 | 647 | 325 | 4.56 / 450.74 | 5 | 56 |
7 | 8 | 0.08 | 450 | 14.14 | 282 | 1794 | 6.35 / 452.53 | 6 | 64 |
Average= | 6.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 67 | 14.39 | 351 | 338 | 0.34 / 440.08 | 6 | 19 |
2 | 7 | 2004.12 | 106 | 11.73 | 1667 | 2073 | 2.41 / 442.15 | 19 | 38 |
3 | 13 | 1806.72 | 36 | 12.99 | 1590 | 744 | 3.15 / 442.90 | 5 | 46 |
4 | 13 | 1600.56 | 36 | 13.17 | 1460 | 692 | 3.85 / 443.59 | 5 | 51 |
5 | 13 | 910.72 | 36 | 13.61 | 996 | 488 | 4.33 / 444.08 | 5 | 58 |
6 | 13 | 236.16 | 36 | 14.18 | 485 | 248 | 4.58 / 444.33 | 5 | 51 |
7 | 8 | 0.08 | 450 | 14.12 | 292 | 1855 | 6.44 / 446.18 | 6 | 64 |
Average= | 6.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 67 | 14.36 | 355 | 342 | 0.34 / 433.73 | 6 | 20 |
2 | 7 | 2002.80 | 105 | 11.75 | 1682 | 2075 | 2.42 / 435.81 | 20 | 37 |
3 | 13 | 1912.36 | 36 | 12.85 | 1657 | 767 | 3.18 / 436.57 | 5 | 45 |
4 | 13 | 1367.36 | 36 | 13.31 | 1312 | 629 | 3.81 / 437.20 | 5 | 53 |
5 | 13 | 828.48 | 36 | 13.68 | 939 | 462 | 4.27 / 437.66 | 5 | 58 |
6 | 13 | 169.16 | 36 | 14.23 | 438 | 224 | 4.50 / 437.89 | 5 | 50 |
7 | 8 | 0.08 | 450 | 14.11 | 292 | 1854 | 6.35 / 439.74 | 6 | 67 |
Average= | 6.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 67 | 14.33 | 363 | 349 | 0.35 / 427.26 | 6 | 21 |
2 | 7 | 2002.44 | 105 | 11.77 | 1687 | 2085 | 2.43 / 429.34 | 21 | 38 |
3 | 13 | 1908.52 | 36 | 12.89 | 1649 | 765 | 3.20 / 430.11 | 5 | 45 |
4 | 13 | 1366.80 | 36 | 13.33 | 1309 | 628 | 3.83 / 430.74 | 5 | 54 |
5 | 13 | 815.04 | 36 | 13.69 | 932 | 459 | 4.29 / 431.20 | 5 | 59 |
6 | 13 | 479.96 | 36 | 13.95 | 679 | 341 | 4.63 / 431.54 | 5 | 57 |
7 | 8 | 0.12 | 450 | 14.10 | 292 | 1853 | 6.48 / 433.39 | 6 | 65 |
Average= | 6.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 66 | 14.33 | 365 | 345 | 0.35 / 420.87 | 6 | 21 |
2 | 3 | 1023.80 | 1 | 13.24 | 1057 | 14 | 0.36 / 420.88 | 5 | 24 |
3 | 7 | 2008.24 | 105 | 11.81 | 1678 | 2081 | 2.44 / 422.96 | 24 | 38 |
4 | 13 | 1907.48 | 36 | 12.89 | 1650 | 766 | 3.21 / 423.73 | 5 | 45 |
5 | 13 | 1484.24 | 36 | 13.28 | 1384 | 662 | 3.87 / 424.39 | 5 | 52 |
6 | 13 | 820.76 | 36 | 13.70 | 934 | 461 | 4.33 / 424.85 | 5 | 58 |
7 | 13 | 176.12 | 36 | 14.25 | 434 | 223 | 4.55 / 425.07 | 5 | 48 |
8 | 8 | 0.16 | 450 | 14.13 | 289 | 1838 | 6.39 / 426.91 | 5 | 64 |
Average= | 6.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 63 | 14.37 | 357 | 323 | 0.32 / 414.45 | 6 | 22 |
2 | 3 | 1051.20 | 3 | 13.53 | 1086 | 44 | 0.37 / 414.49 | 5 | 41 |
3 | 7 | 2001.64 | 105 | 11.82 | 1681 | 2086 | 2.45 / 416.58 | 41 | 38 |
4 | 13 | 1902.64 | 36 | 12.93 | 1645 | 766 | 3.22 / 417.34 | 5 | 45 |
5 | 13 | 1474.40 | 36 | 13.33 | 1375 | 660 | 3.88 / 418.00 | 5 | 52 |
6 | 13 | 714.72 | 36 | 13.79 | 855 | 424 | 4.30 / 418.43 | 5 | 58 |
7 | 13 | 289.12 | 36 | 14.15 | 525 | 267 | 4.57 / 418.70 | 5 | 51 |
8 | 8 | 0.08 | 450 | 14.14 | 287 | 1826 | 6.40 / 420.52 | 6 | 64 |
Average= | 6.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 67 | 14.34 | 360 | 346 | 0.35 / 408.16 | 6 | 23 |
2 | 3 | 953.88 | -1 | 14.34 | 360 | 0 | 0.00 / 408.16 | 6 | 23 |
3 | 7 | 2010.04 | 105 | 11.87 | 1687 | 2103 | 2.45 / 410.26 | 23 | 38 |
4 | 13 | 1810.20 | 36 | 13.09 | 1593 | 751 | 3.20 / 411.01 | 5 | 47 |
5 | 13 | 1289.32 | 36 | 13.45 | 1259 | 610 | 3.81 / 411.62 | 5 | 54 |
6 | 13 | 854.08 | 36 | 13.72 | 958 | 473 | 4.28 / 412.09 | 5 | 59 |
7 | 13 | 90.52 | 36 | 14.34 | 365 | 188 | 4.47 / 412.28 | 5 | 46 |
8 | 8 | 0.16 | 450 | 14.13 | 290 | 1844 | 6.31 / 414.13 | 6 | 62 |
Average= | 6.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 65 | 14.36 | 371 | 346 | 0.35 / 401.73 | 6 | 23 |
2 | 3 | 1023.40 | 1 | 13.32 | 1043 | 14 | 0.36 / 401.75 | 5 | 23 |
3 | 7 | 2006.80 | 106 | 11.94 | 1692 | 2141 | 2.50 / 403.89 | 23 | 38 |
4 | 13 | 1915.12 | 36 | 12.99 | 1658 | 775 | 3.28 / 404.67 | 5 | 45 |
5 | 13 | 1287.60 | 36 | 13.49 | 1251 | 608 | 3.88 / 405.27 | 5 | 54 |
6 | 13 | 857.40 | 36 | 13.74 | 961 | 475 | 4.36 / 405.75 | 5 | 57 |
7 | 13 | 188.68 | 36 | 14.30 | 440 | 227 | 4.59 / 405.97 | 5 | 45 |
8 | 8 | 0.52 | 450 | 14.17 | 288 | 1836 | 6.42 / 407.81 | 7 | 69 |
Average= | 6.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 65 | 14.36 | 362 | 338 | 0.34 / 395.42 | 6 | 24 |
2 | 7 | 2005.80 | 106 | 12.02 | 1680 | 2141 | 2.48 / 397.56 | 24 | 38 |
3 | 13 | 1911.44 | 36 | 13.04 | 1646 | 773 | 3.25 / 398.33 | 5 | 44 |
4 | 13 | 1058.60 | 36 | 13.61 | 1097 | 537 | 3.79 / 398.87 | 5 | 55 |
5 | 13 | 754.08 | 36 | 13.82 | 879 | 437 | 4.23 / 399.30 | 5 | 57 |
6 | 13 | 207.08 | 36 | 14.30 | 454 | 234 | 4.46 / 399.54 | 5 | 45 |
7 | 8 | 0.08 | 450 | 14.18 | 290 | 1850 | 6.31 / 401.39 | 6 | 63 |
Average= | 6.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 65 | 14.41 | 362 | 339 | 0.34 / 388.97 | 6 | 22 |
2 | 3 | 1016.32 | 1 | 13.20 | 1042 | 14 | 0.35 / 388.98 | 5 | 18 |
3 | 7 | 2010.00 | 106 | 12.09 | 1690 | 2166 | 2.52 / 391.15 | 18 | 39 |
4 | 13 | 1917.16 | 36 | 13.05 | 1661 | 780 | 3.30 / 391.93 | 5 | 45 |
5 | 13 | 1170.52 | 36 | 13.58 | 1174 | 574 | 3.87 / 392.50 | 5 | 54 |
6 | 13 | 850.64 | 36 | 13.77 | 952 | 472 | 4.34 / 392.97 | 5 | 57 |
7 | 13 | 281.20 | 36 | 14.24 | 510 | 261 | 4.61 / 393.23 | 5 | 46 |
8 | 8 | 0.16 | 450 | 14.18 | 289 | 1844 | 6.45 / 395.08 | 6 | 68 |
Average= | 6.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 68 | 14.39 | 356 | 348 | 0.35 / 382.58 | 6 | 22 |
2 | 3 | 959.28 | -1 | 14.39 | 356 | 0 | 0.00 / 382.58 | 6 | 22 |
3 | 7 | 2004.68 | 105 | 12.16 | 1685 | 2151 | 2.50 / 384.73 | 22 | 39 |
4 | 13 | 1910.04 | 36 | 13.08 | 1645 | 775 | 3.27 / 385.50 | 5 | 45 |
5 | 13 | 1363.64 | 36 | 13.49 | 1302 | 632 | 3.91 / 386.14 | 5 | 53 |
6 | 13 | 821.56 | 36 | 13.81 | 927 | 461 | 4.37 / 386.60 | 5 | 56 |
7 | 13 | 162.28 | 36 | 14.36 | 414 | 214 | 4.58 / 386.81 | 5 | 43 |
8 | 8 | -0.04 | 450 | 14.21 | 284 | 1816 | 6.40 / 388.63 | 6 | 69 |
Average= | 6.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 68 | 14.43 | 355 | 348 | 0.35 / 376.31 | 6 | 22 |
2 | 7 | 2006.08 | 105 | 12.27 | 1686 | 2172 | 2.52 / 378.48 | 22 | 38 |
3 | 13 | 1804.52 | 36 | 13.23 | 1584 | 754 | 3.27 / 379.23 | 5 | 46 |
4 | 13 | 1184.76 | 36 | 13.62 | 1176 | 577 | 3.85 / 379.81 | 5 | 53 |
5 | 13 | 752.72 | 36 | 13.89 | 869 | 435 | 4.29 / 380.24 | 5 | 54 |
6 | 13 | 54.24 | 36 | 14.46 | 326 | 170 | 4.46 / 380.41 | 6 | 40 |
7 | 8 | 0.04 | 450 | 14.22 | 284 | 1817 | 6.27 / 382.23 | 6 | 62 |
Average= | 6.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 68 | 14.41 | 355 | 348 | 0.35 / 369.92 | 6 | 21 |
2 | 7 | 2007.28 | 105 | 12.35 | 1689 | 2190 | 2.54 / 372.11 | 21 | 38 |
3 | 13 | 1805.16 | 36 | 13.26 | 1586 | 757 | 3.30 / 372.86 | 5 | 46 |
4 | 13 | 1373.84 | 36 | 13.52 | 1313 | 639 | 3.93 / 373.50 | 5 | 52 |
5 | 13 | 718.08 | 36 | 13.91 | 842 | 422 | 4.36 / 373.92 | 5 | 54 |
6 | 13 | 166.40 | 36 | 14.38 | 416 | 215 | 4.57 / 374.14 | 5 | 42 |
7 | 8 | 0.28 | 450 | 14.22 | 284 | 1817 | 6.39 / 375.96 | 6 | 53 |
Average= | 6.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 68 | 14.43 | 363 | 356 | 0.36 / 363.63 | 6 | 21 |
2 | 7 | 2003.40 | 105 | 12.44 | 1688 | 2205 | 2.56 / 365.83 | 21 | 39 |
3 | 13 | 1914.44 | 36 | 13.17 | 1649 | 782 | 3.34 / 366.62 | 5 | 44 |
4 | 13 | 1183.76 | 36 | 13.64 | 1181 | 580 | 3.92 / 367.20 | 5 | 53 |
5 | 13 | 559.64 | 36 | 14.07 | 721 | 365 | 4.29 / 367.56 | 5 | 49 |
6 | 13 | 128.68 | 36 | 14.42 | 386 | 200 | 4.49 / 367.76 | 6 | 41 |
7 | 8 | 0.28 | 450 | 14.24 | 282 | 1807 | 6.30 / 369.57 | 6 | 60 |
Average= | 6.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 68 | 14.43 | 360 | 353 | 0.35 / 357.21 | 6 | 21 |
2 | 7 | 2003.60 | 105 | 12.51 | 1687 | 2216 | 2.57 / 359.42 | 5 | 39 |
3 | 13 | 1908.76 | 36 | 13.22 | 1649 | 785 | 3.35 / 360.21 | 5 | 44 |
4 | 13 | 1363.20 | 36 | 13.56 | 1308 | 639 | 3.99 / 360.85 | 5 | 52 |
5 | 13 | 711.04 | 36 | 13.95 | 834 | 419 | 4.41 / 361.26 | 5 | 53 |
6 | 13 | 165.76 | 36 | 14.40 | 411 | 213 | 4.62 / 361.48 | 5 | 41 |
7 | 8 | 0.12 | 450 | 14.25 | 280 | 1795 | 6.42 / 363.27 | 6 | 54 |
Average= | 6.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 67 | 14.42 | 355 | 343 | 0.34 / 350.83 | 6 | 20 |
2 | 3 | 1009.80 | 1 | 13.14 | 1025 | 13 | 0.36 / 350.85 | 5 | 10 |
3 | 7 | 2013.32 | 105 | 12.56 | 1694 | 2234 | 2.59 / 353.08 | 10 | 39 |
4 | 13 | 1914.20 | 36 | 13.23 | 1647 | 784 | 3.37 / 353.87 | 5 | 45 |
5 | 13 | 1171.24 | 36 | 13.67 | 1166 | 574 | 3.95 / 354.44 | 5 | 54 |
6 | 13 | 755.84 | 36 | 13.93 | 869 | 436 | 4.38 / 354.87 | 5 | 53 |
7 | 13 | 107.72 | 36 | 14.45 | 366 | 190 | 4.57 / 355.07 | 6 | 40 |
8 | 8 | 0.36 | 450 | 14.24 | 279 | 1788 | 6.36 / 356.85 | 6 | 57 |
Average= | 6.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 67 | 14.46 | 362 | 351 | 0.35 / 344.49 | 6 | 20 |
2 | 7 | 2010.76 | 105 | 12.61 | 1692 | 2240 | 2.59 / 346.73 | 5 | 39 |
3 | 13 | 1706.32 | 36 | 13.41 | 1526 | 737 | 3.33 / 347.47 | 5 | 47 |
4 | 13 | 1189.68 | 36 | 13.66 | 1186 | 583 | 3.91 / 348.05 | 5 | 54 |
5 | 13 | 751.92 | 36 | 13.92 | 869 | 435 | 4.35 / 348.48 | 5 | 54 |
6 | 13 | 88.84 | 36 | 14.46 | 360 | 187 | 4.53 / 348.67 | 6 | 41 |
7 | 8 | -0.04 | 450 | 14.23 | 284 | 1819 | 6.35 / 350.49 | 7 | 61 |
Average= | 6.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 66 | 14.47 | 354 | 338 | 0.34 / 338.20 | 6 | 21 |
2 | 3 | 1017.56 | 1 | 13.49 | 1030 | 14 | 0.35 / 338.21 | 5 | 20 |
3 | 7 | 2011.72 | 105 | 12.66 | 1685 | 2240 | 2.59 / 340.45 | 20 | 39 |
4 | 13 | 1713.36 | 36 | 13.43 | 1527 | 738 | 3.33 / 341.19 | 5 | 47 |
5 | 13 | 1171.36 | 36 | 13.69 | 1170 | 577 | 3.91 / 341.77 | 5 | 54 |
6 | 13 | 636.20 | 36 | 14.02 | 777 | 392 | 4.30 / 342.16 | 5 | 52 |
7 | 13 | 100.80 | 36 | 14.46 | 361 | 188 | 4.49 / 342.35 | 6 | 41 |
8 | 8 | 0.04 | 450 | 14.26 | 279 | 1790 | 6.28 / 344.14 | 6 | 63 |
Average= | 6.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 66 | 14.43 | 356 | 339 | 0.34 / 331.77 | 6 | 19 |
2 | 7 | 2005.36 | 105 | 12.69 | 1688 | 2249 | 2.59 / 334.02 | 19 | 39 |
3 | 13 | 1905.40 | 36 | 13.30 | 1639 | 785 | 3.37 / 334.80 | 5 | 44 |
4 | 13 | 1247.76 | 36 | 13.67 | 1223 | 602 | 3.97 / 335.40 | 5 | 52 |
5 | 13 | 811.76 | 36 | 13.92 | 913 | 458 | 4.43 / 335.86 | 5 | 54 |
6 | 13 | 70.28 | 36 | 14.48 | 348 | 181 | 4.61 / 336.04 | 6 | 41 |
7 | 8 | 0.20 | 450 | 14.24 | 284 | 1820 | 6.43 / 337.86 | 6 | 62 |
Average= | 6.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 66 | 14.48 | 353 | 337 | 0.34 / 325.23 | 6 | 18 |
2 | 7 | 2007.12 | 105 | 12.70 | 1697 | 2263 | 2.60 / 327.49 | 5 | 40 |
3 | 13 | 1914.44 | 36 | 13.28 | 1659 | 793 | 3.39 / 328.28 | 5 | 45 |
4 | 13 | 1473.56 | 36 | 13.57 | 1379 | 674 | 4.07 / 328.96 | 5 | 51 |
5 | 13 | 795.32 | 36 | 13.91 | 903 | 452 | 4.52 / 329.41 | 5 | 55 |
6 | 13 | 121.60 | 36 | 14.44 | 384 | 200 | 4.72 / 329.61 | 5 | 43 |
7 | 8 | 0.00 | 450 | 14.24 | 284 | 1820 | 6.54 / 331.43 | 6 | 61 |
Average= | 6.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 66 | 14.45 | 359 | 342 | 0.34 / 318.77 | 6 | 18 |
2 | 7 | 2007.92 | 105 | 12.69 | 1698 | 2263 | 2.60 / 321.03 | 18 | 40 |
3 | 13 | 1908.44 | 36 | 13.28 | 1651 | 789 | 3.39 / 321.82 | 5 | 45 |
4 | 13 | 1267.96 | 36 | 13.65 | 1236 | 607 | 4.00 / 322.43 | 5 | 53 |
5 | 13 | 622.24 | 36 | 14.01 | 783 | 395 | 4.40 / 322.82 | 5 | 54 |
6 | 13 | 187.12 | 36 | 14.35 | 443 | 229 | 4.63 / 323.05 | 5 | 46 |
7 | 8 | 0.12 | 450 | 14.21 | 287 | 1835 | 6.46 / 324.89 | 6 | 55 |
Average= | 6.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 66 | 14.52 | 349 | 334 | 0.33 / 312.25 | 6 | 17 |
2 | 7 | 2004.32 | 105 | 12.68 | 1694 | 2255 | 2.59 / 314.50 | 17 | 39 |
3 | 13 | 1795.84 | 36 | 13.40 | 1582 | 763 | 3.35 / 315.27 | 5 | 47 |
4 | 13 | 1225.88 | 36 | 13.66 | 1217 | 598 | 3.95 / 315.87 | 5 | 54 |
5 | 13 | 582.40 | 36 | 14.03 | 752 | 380 | 4.33 / 316.25 | 5 | 55 |
6 | 13 | 162.76 | 36 | 14.37 | 418 | 216 | 4.55 / 316.46 | 5 | 46 |
7 | 13 | 14.20 | 36 | 14.47 | 304 | 158 | 4.71 / 316.62 | 6 | 44 |
8 | 8 | 0.16 | 450 | 14.19 | 283 | 1807 | 6.51 / 318.43 | 6 | 59 |
Average= | 6.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 66 | 14.52 | 344 | 330 | 0.33 / 305.55 | 6 | 16 |
2 | 7 | 2011.44 | 105 | 12.70 | 1696 | 2262 | 2.59 / 307.81 | 16 | 40 |
3 | 13 | 1705.20 | 36 | 13.45 | 1528 | 740 | 3.33 / 308.55 | 5 | 48 |
4 | 13 | 1206.96 | 36 | 13.68 | 1196 | 589 | 3.92 / 309.14 | 5 | 54 |
5 | 13 | 864.60 | 36 | 13.85 | 969 | 483 | 4.40 / 309.62 | 5 | 57 |
6 | 13 | 50.96 | 36 | 14.45 | 336 | 175 | 4.58 / 309.79 | 5 | 46 |
7 | 13 | 18.64 | 36 | 14.39 | 310 | 161 | 4.74 / 309.95 | 6 | 45 |
8 | 13 | 10.24 | 36 | 14.34 | 299 | 154 | 4.89 / 310.11 | 6 | 46 |
9 | 8 | -0.08 | 450 | 14.18 | 283 | 1806 | 6.70 / 311.91 | 6 | 74 |
Average= | 6.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 66 | 14.55 | 340 | 327 | 0.33 / 298.95 | 6 | 16 |
2 | 7 | 2002.64 | 105 | 12.68 | 1696 | 2258 | 2.58 / 301.21 | 16 | 40 |
3 | 13 | 1684.36 | 36 | 13.44 | 1521 | 736 | 3.32 / 301.94 | 5 | 49 |
4 | 13 | 1493.20 | 36 | 13.54 | 1394 | 679 | 4.00 / 302.62 | 5 | 52 |
5 | 13 | 674.64 | 36 | 13.96 | 825 | 415 | 4.41 / 303.04 | 5 | 57 |
6 | 13 | 69.84 | 36 | 14.44 | 354 | 184 | 4.60 / 303.22 | 5 | 46 |
7 | 13 | 39.64 | 36 | 14.36 | 328 | 170 | 4.77 / 303.39 | 5 | 46 |
8 | 8 | 0.08 | 450 | 14.19 | 286 | 1826 | 6.59 / 305.22 | 6 | 71 |
Average= | 5.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 66 | 14.56 | 336 | 323 | 0.32 / 292.66 | 6 | 14 |
2 | 7 | 2011.60 | 105 | 12.64 | 1695 | 2250 | 2.57 / 294.91 | 14 | 39 |
3 | 13 | 1707.84 | 36 | 13.43 | 1524 | 737 | 3.31 / 295.65 | 5 | 47 |
4 | 13 | 1172.16 | 36 | 13.68 | 1172 | 577 | 3.89 / 296.22 | 5 | 54 |
5 | 13 | 647.92 | 36 | 14.00 | 797 | 402 | 4.29 / 296.63 | 5 | 56 |
6 | 13 | 97.44 | 36 | 14.44 | 371 | 193 | 4.48 / 296.82 | 5 | 45 |
7 | 8 | 0.12 | 450 | 14.26 | 281 | 1803 | 6.28 / 298.62 | 6 | 56 |
Average= | 5.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 66 | 14.55 | 344 | 330 | 0.33 / 286.12 | 6 | 14 |
2 | 7 | 2009.12 | 106 | 12.61 | 1699 | 2271 | 2.60 / 288.39 | 14 | 39 |
3 | 13 | 1705.00 | 36 | 13.41 | 1525 | 736 | 3.34 / 289.13 | 5 | 48 |
4 | 13 | 1278.76 | 36 | 13.64 | 1242 | 610 | 3.95 / 289.74 | 5 | 53 |
5 | 13 | 726.20 | 36 | 13.94 | 859 | 431 | 4.38 / 290.17 | 5 | 55 |
6 | 13 | 172.68 | 36 | 14.38 | 426 | 221 | 4.60 / 290.39 | 5 | 46 |
7 | 13 | 20.28 | 36 | 14.50 | 308 | 161 | 4.76 / 290.55 | 6 | 43 |
8 | 8 | 0.12 | 450 | 14.24 | 279 | 1788 | 6.55 / 292.34 | 6 | 65 |
Average= | 5.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 66 | 14.56 | 338 | 325 | 0.32 / 279.74 | 6 | 14 |
2 | 7 | 2006.24 | 105 | 12.60 | 1688 | 2233 | 2.56 / 281.97 | 5 | 39 |
3 | 13 | 1804.16 | 36 | 13.34 | 1586 | 762 | 3.32 / 282.73 | 5 | 47 |
4 | 13 | 1278.48 | 36 | 13.61 | 1246 | 610 | 3.93 / 283.34 | 5 | 54 |
5 | 13 | 851.24 | 36 | 13.87 | 946 | 472 | 4.40 / 283.81 | 5 | 56 |
6 | 13 | 89.04 | 36 | 14.46 | 363 | 189 | 4.59 / 284.00 | 5 | 43 |
7 | 8 | 0.08 | 450 | 14.29 | 278 | 1788 | 6.38 / 285.79 | 6 | 57 |
Average= | 5.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 66 | 14.56 | 337 | 324 | 0.32 / 273.24 | 6 | 13 |
2 | 7 | 2013.04 | 106 | 12.60 | 1697 | 2267 | 2.59 / 275.50 | 13 | 38 |
3 | 13 | 1812.52 | 36 | 13.34 | 1594 | 766 | 3.36 / 276.27 | 5 | 46 |
4 | 13 | 1265.72 | 36 | 13.63 | 1234 | 605 | 3.96 / 276.87 | 5 | 52 |
5 | 13 | 710.92 | 36 | 13.98 | 836 | 421 | 4.38 / 277.29 | 5 | 54 |
6 | 13 | 77.56 | 36 | 14.49 | 345 | 180 | 4.56 / 277.47 | 6 | 42 |
7 | 13 | 20.40 | 36 | 14.49 | 303 | 158 | 4.72 / 277.63 | 6 | 42 |
8 | 8 | 0.04 | 450 | 14.26 | 277 | 1778 | 6.50 / 279.41 | 6 | 64 |
Average= | 5.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 66 | 14.57 | 335 | 322 | 0.32 / 266.87 | 6 | 13 |
2 | 7 | 2008.20 | 105 | 12.60 | 1689 | 2235 | 2.56 / 269.10 | 13 | 38 |
3 | 13 | 1705.72 | 36 | 13.39 | 1525 | 735 | 3.29 / 269.84 | 5 | 47 |
4 | 13 | 1089.64 | 36 | 13.73 | 1110 | 549 | 3.84 / 270.39 | 5 | 53 |
5 | 13 | 680.84 | 36 | 14.00 | 816 | 411 | 4.25 / 270.80 | 5 | 53 |
6 | 13 | 59.04 | 36 | 14.52 | 334 | 175 | 4.43 / 270.97 | 6 | 42 |
7 | 13 | 29.76 | 36 | 14.42 | 313 | 162 | 4.59 / 271.14 | 6 | 43 |
8 | 8 | 0.08 | 450 | 14.25 | 277 | 1776 | 6.37 / 272.91 | 7 | 64 |
Average= | 5.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 66 | 14.59 | 336 | 324 | 0.32 / 260.49 | 6 | 13 |
2 | 7 | 2002.20 | 105 | 12.62 | 1687 | 2235 | 2.56 / 262.73 | 13 | 38 |
3 | 13 | 1707.04 | 36 | 13.40 | 1525 | 736 | 3.29 / 263.46 | 5 | 47 |
4 | 13 | 1083.52 | 36 | 13.72 | 1114 | 550 | 3.84 / 264.01 | 5 | 53 |
5 | 13 | 665.00 | 36 | 14.00 | 809 | 408 | 4.25 / 264.42 | 5 | 54 |
6 | 13 | 112.36 | 36 | 14.46 | 374 | 195 | 4.45 / 264.62 | 5 | 44 |
7 | 13 | 26.56 | 36 | 14.50 | 307 | 160 | 4.61 / 264.78 | 6 | 44 |
8 | 8 | 0.00 | 450 | 14.26 | 276 | 1771 | 6.38 / 266.55 | 6 | 61 |
Average= | 5.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 66 | 14.58 | 340 | 327 | 0.33 / 253.92 | 6 | 14 |
2 | 7 | 2011.04 | 105 | 12.63 | 1692 | 2244 | 2.57 / 256.16 | 14 | 38 |
3 | 13 | 1714.52 | 36 | 13.41 | 1527 | 737 | 3.31 / 256.90 | 5 | 47 |
4 | 13 | 1090.04 | 36 | 13.73 | 1116 | 552 | 3.86 / 257.45 | 5 | 53 |
5 | 13 | 770.04 | 36 | 13.95 | 889 | 446 | 4.31 / 257.90 | 5 | 54 |
6 | 13 | 51.92 | 36 | 14.52 | 331 | 173 | 4.48 / 258.07 | 6 | 42 |
7 | 13 | 26.32 | 36 | 14.43 | 311 | 162 | 4.64 / 258.23 | 6 | 43 |
8 | 13 | 13.88 | 36 | 14.41 | 299 | 155 | 4.80 / 258.39 | 6 | 44 |
9 | 8 | 0.04 | 450 | 14.25 | 278 | 1783 | 6.58 / 260.17 | 6 | 66 |
Average= | 5.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 65 | 14.60 | 336 | 319 | 0.32 / 247.65 | 6 | 15 |
2 | 7 | 2011.08 | 105 | 12.65 | 1691 | 2246 | 2.56 / 249.90 | 5 | 39 |
3 | 13 | 1710.08 | 36 | 13.42 | 1530 | 739 | 3.30 / 250.64 | 5 | 47 |
4 | 13 | 1192.20 | 36 | 13.70 | 1185 | 584 | 3.89 / 251.22 | 5 | 53 |
5 | 13 | 659.72 | 36 | 14.04 | 801 | 405 | 4.29 / 251.63 | 5 | 54 |
6 | 13 | 54.68 | 36 | 14.54 | 329 | 172 | 4.47 / 251.80 | 6 | 42 |
7 | 8 | 0.08 | 450 | 14.30 | 278 | 1789 | 6.25 / 253.59 | 6 | 58 |
Average= | 5.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 65 | 14.59 | 332 | 315 | 0.31 / 241.38 | 6 | 14 |
2 | 7 | 2008.00 | 106 | 12.66 | 1690 | 2268 | 2.58 / 243.64 | 14 | 39 |
3 | 13 | 1604.04 | 36 | 13.50 | 1460 | 710 | 3.29 / 244.35 | 5 | 49 |
4 | 13 | 1174.80 | 36 | 13.72 | 1174 | 580 | 3.87 / 244.93 | 5 | 54 |
5 | 13 | 725.04 | 36 | 14.00 | 860 | 433 | 4.31 / 245.37 | 5 | 55 |
6 | 13 | 40.64 | 36 | 14.56 | 318 | 167 | 4.47 / 245.53 | 6 | 41 |
7 | 8 | -0.04 | 450 | 14.31 | 280 | 1803 | 6.28 / 247.34 | 6 | 57 |
Average= | 5.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 65 | 14.61 | 341 | 324 | 0.32 / 235.07 | 6 | 13 |
2 | 7 | 2011.68 | 105 | 12.69 | 1690 | 2252 | 2.58 / 237.32 | 5 | 40 |
3 | 13 | 1699.56 | 36 | 13.46 | 1522 | 738 | 3.31 / 238.06 | 5 | 49 |
4 | 13 | 1066.60 | 36 | 13.79 | 1096 | 544 | 3.86 / 238.61 | 5 | 56 |
5 | 13 | 635.04 | 36 | 14.07 | 785 | 398 | 4.25 / 239.00 | 5 | 55 |
6 | 13 | 24.72 | 36 | 14.59 | 296 | 155 | 4.41 / 239.16 | 6 | 43 |
7 | 13 | 13.76 | 36 | 14.51 | 291 | 152 | 4.56 / 239.31 | 6 | 44 |
8 | 8 | 0.04 | 450 | 14.29 | 272 | 1749 | 6.31 / 241.06 | 6 | 60 |
Average= | 5.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 65 | 14.57 | 342 | 324 | 0.32 / 228.62 | 6 | 17 |
2 | 7 | 2010.68 | 105 | 12.74 | 1685 | 2254 | 2.58 / 230.87 | 5 | 40 |
3 | 13 | 1809.72 | 36 | 13.45 | 1584 | 767 | 3.34 / 231.64 | 5 | 47 |
4 | 13 | 1259.52 | 36 | 13.72 | 1227 | 606 | 3.95 / 232.24 | 5 | 54 |
5 | 13 | 611.04 | 36 | 14.11 | 767 | 390 | 4.34 / 232.63 | 5 | 54 |
6 | 13 | 40.52 | 36 | 14.58 | 320 | 168 | 4.51 / 232.80 | 6 | 43 |
7 | 13 | 6.60 | 36 | 14.52 | 293 | 153 | 4.66 / 232.95 | 6 | 45 |
8 | 8 | 0.12 | 450 | 14.29 | 279 | 1794 | 6.46 / 234.75 | 6 | 61 |
Average= | 5.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 65 | 14.57 | 353 | 334 | 0.33 / 222.27 | 6 | 16 |
2 | 7 | 2010.08 | 106 | 12.78 | 1690 | 2289 | 2.62 / 224.55 | 5 | 40 |
3 | 13 | 1704.28 | 36 | 13.52 | 1528 | 744 | 3.37 / 225.30 | 5 | 48 |
4 | 13 | 1075.64 | 36 | 13.83 | 1104 | 550 | 3.92 / 225.85 | 5 | 54 |
5 | 13 | 751.44 | 36 | 14.03 | 878 | 443 | 4.36 / 226.29 | 5 | 56 |
6 | 13 | 43.32 | 36 | 14.58 | 327 | 172 | 4.53 / 226.46 | 5 | 43 |
7 | 8 | 0.08 | 450 | 14.32 | 284 | 1830 | 6.36 / 228.29 | 6 | 63 |
Average= | 5.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 63 | 14.60 | 349 | 321 | 0.32 / 215.91 | 6 | 17 |
2 | 3 | 1028.40 | 1 | 14.17 | 1045 | 15 | 0.34 / 215.92 | 5 | 32 |
3 | 7 | 2009.04 | 106 | 12.83 | 1696 | 2307 | 2.64 / 218.23 | 32 | 40 |
4 | 13 | 1594.20 | 36 | 13.61 | 1456 | 713 | 3.36 / 218.94 | 5 | 49 |
5 | 13 | 1174.12 | 36 | 13.81 | 1174 | 584 | 3.94 / 219.53 | 5 | 55 |
6 | 13 | 630.92 | 36 | 14.12 | 785 | 399 | 4.34 / 219.93 | 5 | 55 |
7 | 13 | 23.72 | 36 | 14.62 | 305 | 161 | 4.50 / 220.09 | 6 | 41 |
8 | 8 | 0.04 | 450 | 14.32 | 286 | 1843 | 6.34 / 221.93 | 6 | 60 |
Average= | 5.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 62 | 14.58 | 364 | 329 | 0.33 / 209.52 | 6 | 19 |
2 | 3 | 1037.84 | 2 | 14.32 | 1067 | 31 | 0.36 / 209.55 | 5 | 36 |
3 | 7 | 2012.92 | 105 | 12.89 | 1689 | 2286 | 2.65 / 211.84 | 36 | 40 |
4 | 13 | 1812.04 | 36 | 13.54 | 1586 | 773 | 3.42 / 212.61 | 5 | 47 |
5 | 13 | 1139.44 | 36 | 13.85 | 1143 | 570 | 3.99 / 213.18 | 5 | 55 |
6 | 13 | 599.48 | 36 | 14.16 | 763 | 389 | 4.38 / 213.57 | 5 | 54 |
7 | 13 | 78.08 | 36 | 14.59 | 346 | 182 | 4.56 / 213.75 | 5 | 43 |
8 | 8 | 0.08 | 450 | 14.33 | 285 | 1838 | 6.40 / 215.59 | 6 | 57 |
Average= | 5.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 65 | 14.56 | 358 | 339 | 0.34 / 203.31 | 6 | 21 |
2 | 3 | 957.72 | -1 | 14.56 | 358 | 0 | 0.00 / 203.31 | 6 | 21 |
3 | 7 | 2006.20 | 105 | 12.91 | 1696 | 2299 | 2.64 / 205.61 | 21 | 41 |
4 | 13 | 1802.24 | 36 | 13.56 | 1593 | 778 | 3.42 / 206.39 | 5 | 48 |
5 | 13 | 1149.04 | 36 | 13.84 | 1159 | 577 | 3.99 / 206.96 | 5 | 55 |
6 | 13 | 609.16 | 36 | 14.16 | 771 | 393 | 4.39 / 207.36 | 5 | 55 |
7 | 8 | 0.24 | 450 | 14.36 | 284 | 1835 | 6.22 / 209.19 | 6 | 58 |
Average= | 5.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 62 | 14.60 | 353 | 320 | 0.32 / 196.84 | 6 | 21 |
2 | 3 | 1046.60 | 2 | 14.41 | 1096 | 32 | 0.35 / 196.88 | 5 | 40 |
3 | 7 | 2006.28 | 106 | 12.94 | 1692 | 2321 | 2.67 / 199.20 | 40 | 41 |
4 | 13 | 1908.16 | 36 | 13.47 | 1651 | 801 | 3.47 / 200.00 | 5 | 46 |
5 | 13 | 1142.16 | 36 | 13.86 | 1157 | 577 | 4.05 / 200.57 | 5 | 56 |
6 | 13 | 703.72 | 36 | 14.11 | 841 | 427 | 4.48 / 201.00 | 5 | 57 |
7 | 13 | 33.32 | 36 | 14.62 | 314 | 165 | 4.64 / 201.17 | 5 | 43 |
8 | 8 | 0.08 | 450 | 14.32 | 280 | 1804 | 6.45 / 202.97 | 6 | 59 |
Average= | 5.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 65 | 14.59 | 348 | 330 | 0.33 / 190.77 | 6 | 21 |
2 | 3 | 962.32 | -1 | 14.59 | 348 | 0 | 0.00 / 190.77 | 6 | 21 |
3 | 7 | 2008.92 | 105 | 12.96 | 1701 | 2315 | 2.64 / 193.08 | 21 | 41 |
4 | 13 | 1705.60 | 36 | 13.64 | 1527 | 750 | 3.39 / 193.83 | 5 | 49 |
5 | 13 | 974.56 | 36 | 13.96 | 1035 | 520 | 3.91 / 194.35 | 5 | 56 |
6 | 13 | 466.64 | 36 | 14.31 | 654 | 337 | 4.25 / 194.69 | 5 | 51 |
7 | 8 | 0.20 | 450 | 14.36 | 284 | 1835 | 6.09 / 196.52 | 6 | 54 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 60 | 14.59 | 373 | 327 | 0.33 / 184.30 | 6 | 21 |
2 | 10 | 1020.52 | 5 | 14.59 | 1067 | 78 | 0.40 / 184.38 | 5 | 37 |
3 | 7 | 2008.80 | 105 | 13.00 | 1700 | 2320 | 2.72 / 186.70 | 5 | 41 |
4 | 13 | 1910.16 | 36 | 13.51 | 1660 | 807 | 3.53 / 187.50 | 5 | 46 |
5 | 13 | 1145.92 | 36 | 13.89 | 1163 | 582 | 4.11 / 188.09 | 5 | 55 |
6 | 13 | 591.08 | 36 | 14.22 | 760 | 389 | 4.50 / 188.47 | 5 | 54 |
7 | 13 | 17.16 | 36 | 14.67 | 306 | 162 | 4.66 / 188.64 | 6 | 41 |
8 | 8 | 0.00 | 450 | 14.35 | 279 | 1802 | 6.47 / 190.44 | 6 | 60 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 63 | 14.66 | 314 | 290 | 0.29 / 178.01 | 6 | 21 |
2 | 3 | 962.00 | -1 | 14.66 | 314 | 0 | 0.00 / 178.01 | 6 | 21 |
3 | 7 | 2003.24 | 105 | 13.03 | 1661 | 2272 | 2.56 / 180.28 | 21 | 41 |
4 | 13 | 1707.08 | 36 | 13.68 | 1498 | 738 | 3.30 / 181.02 | 5 | 49 |
5 | 13 | 1256.76 | 36 | 13.86 | 1204 | 601 | 3.90 / 181.62 | 5 | 55 |
6 | 13 | 695.48 | 36 | 14.18 | 802 | 409 | 4.31 / 182.03 | 5 | 56 |
7 | 13 | 58.28 | 36 | 14.66 | 306 | 161 | 4.47 / 182.19 | 6 | 42 |
8 | 8 | 0.08 | 450 | 14.36 | 276 | 1784 | 6.26 / 183.97 | 6 | 62 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 62 | 14.66 | 330 | 300 | 0.30 / 172.00 | 6 | 22 |
2 | 3 | 1023.80 | 1 | 14.47 | 1044 | 15 | 0.32 / 172.01 | 5 | 30 |
3 | 7 | 2005.72 | 105 | 13.06 | 1663 | 2280 | 2.60 / 174.29 | 30 | 41 |
4 | 13 | 1806.28 | 36 | 13.65 | 1555 | 764 | 3.36 / 175.06 | 5 | 48 |
5 | 13 | 1241.40 | 36 | 13.88 | 1192 | 596 | 3.96 / 175.65 | 5 | 55 |
6 | 13 | 479.88 | 36 | 14.35 | 625 | 323 | 4.28 / 175.98 | 5 | 51 |
7 | 13 | 90.12 | 36 | 14.67 | 317 | 167 | 4.45 / 176.14 | 6 | 41 |
8 | 8 | 0.16 | 450 | 14.44 | 242 | 1573 | 6.02 / 177.72 | 10 | 61 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 61 | 14.66 | 331 | 296 | 0.30 / 166.14 | 6 | 22 |
2 | 3 | 1030.24 | 2 | 14.53 | 1055 | 31 | 0.33 / 166.17 | 5 | 33 |
3 | 7 | 2009.68 | 106 | 13.08 | 1667 | 2311 | 2.64 / 168.48 | 33 | 41 |
4 | 13 | 1681.88 | 36 | 13.70 | 1489 | 734 | 3.37 / 169.22 | 5 | 49 |
5 | 13 | 1049.72 | 36 | 13.99 | 1056 | 532 | 3.90 / 169.75 | 5 | 55 |
6 | 13 | 511.68 | 36 | 14.33 | 653 | 337 | 4.24 / 170.09 | 5 | 53 |
7 | 8 | 0.04 | 450 | 14.44 | 248 | 1612 | 5.85 / 171.70 | 6 | 63 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 64 | 14.66 | 316 | 296 | 0.30 / 160.29 | 6 | 22 |
2 | 3 | 954.32 | -1 | 14.66 | 316 | 0 | 0.00 / 160.29 | 6 | 22 |
3 | 7 | 2003.40 | 106 | 13.10 | 1663 | 2309 | 2.61 / 162.60 | 22 | 41 |
4 | 13 | 1801.56 | 36 | 13.67 | 1556 | 766 | 3.37 / 163.37 | 5 | 47 |
5 | 13 | 1040.32 | 36 | 14.00 | 1053 | 531 | 3.90 / 163.90 | 5 | 55 |
6 | 13 | 516.56 | 36 | 14.35 | 656 | 339 | 4.24 / 164.24 | 5 | 52 |
7 | 8 | 0.32 | 450 | 14.45 | 247 | 1606 | 5.85 / 165.85 | 6 | 63 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 64 | 14.68 | 312 | 293 | 0.29 / 154.28 | 6 | 22 |
2 | 7 | 2008.28 | 105 | 13.14 | 1666 | 2299 | 2.59 / 156.58 | 22 | 40 |
3 | 13 | 1692.36 | 36 | 13.73 | 1484 | 734 | 3.33 / 157.32 | 5 | 48 |
4 | 13 | 1056.08 | 36 | 14.00 | 1062 | 535 | 3.86 / 157.85 | 5 | 55 |
5 | 13 | 612.08 | 36 | 14.28 | 735 | 378 | 4.24 / 158.23 | 5 | 54 |
6 | 13 | 76.28 | 36 | 14.67 | 313 | 165 | 4.40 / 158.40 | 6 | 42 |
7 | 8 | 0.04 | 450 | 14.42 | 247 | 1603 | 6.01 / 160.00 | 6 | 62 |
Average= | 5.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 64 | 14.64 | 336 | 315 | 0.31 / 148.38 | 6 | 21 |
2 | 7 | 2009.40 | 106 | 13.16 | 1664 | 2321 | 2.64 / 150.70 | 5 | 40 |
3 | 13 | 1582.52 | 36 | 13.78 | 1416 | 702 | 3.34 / 151.40 | 5 | 49 |
4 | 13 | 1163.28 | 36 | 13.95 | 1138 | 572 | 3.91 / 151.97 | 5 | 54 |
5 | 13 | 709.64 | 36 | 14.22 | 808 | 414 | 4.32 / 152.39 | 5 | 54 |
6 | 8 | 0.32 | 450 | 14.45 | 247 | 1606 | 5.93 / 153.99 | 6 | 64 |
Average= | 5.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 64 | 14.64 | 331 | 310 | 0.31 / 142.18 | 6 | 22 |
2 | 7 | 2003.60 | 105 | 13.19 | 1666 | 2307 | 2.62 / 144.49 | 22 | 40 |
3 | 13 | 1801.44 | 36 | 13.69 | 1558 | 768 | 3.39 / 145.26 | 5 | 47 |
4 | 13 | 1244.40 | 36 | 13.93 | 1193 | 598 | 3.98 / 145.86 | 5 | 53 |
5 | 13 | 476.60 | 36 | 14.40 | 620 | 321 | 4.30 / 146.18 | 5 | 49 |
6 | 13 | 72.32 | 36 | 14.70 | 307 | 162 | 4.47 / 146.34 | 6 | 40 |
7 | 13 | 10.64 | 36 | 14.69 | 259 | 137 | 4.60 / 146.48 | 6 | 39 |
8 | 8 | -0.08 | 450 | 14.43 | 244 | 1584 | 6.19 / 148.06 | 6 | 66 |
Average= | 5.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 64 | 14.67 | 323 | 303 | 0.30 / 136.44 | 6 | 21 |
2 | 7 | 2001.80 | 105 | 13.17 | 1663 | 2300 | 2.60 / 138.74 | 21 | 41 |
3 | 13 | 1673.80 | 36 | 13.74 | 1476 | 730 | 3.33 / 139.47 | 5 | 49 |
4 | 13 | 950.96 | 36 | 14.06 | 988 | 500 | 3.83 / 139.97 | 5 | 55 |
5 | 13 | 338.40 | 36 | 14.48 | 527 | 275 | 4.11 / 140.24 | 5 | 48 |
6 | 8 | 0.36 | 450 | 14.43 | 251 | 1630 | 5.74 / 141.87 | 6 | 58 |
Average= | 5.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 64 | 14.63 | 330 | 309 | 0.31 / 130.31 | 6 | 21 |
2 | 7 | 2013.12 | 105 | 13.18 | 1673 | 2315 | 2.62 / 132.63 | 21 | 41 |
3 | 13 | 1916.68 | 36 | 13.57 | 1626 | 794 | 3.42 / 133.42 | 5 | 46 |
4 | 13 | 1231.64 | 36 | 13.93 | 1184 | 594 | 4.01 / 134.02 | 5 | 54 |
5 | 13 | 561.88 | 36 | 14.31 | 701 | 361 | 4.37 / 134.38 | 5 | 54 |
6 | 13 | 15.72 | 36 | 14.72 | 272 | 144 | 4.52 / 134.52 | 6 | 43 |
7 | 8 | -0.04 | 450 | 14.41 | 249 | 1615 | 6.13 / 136.14 | 6 | 61 |
Average= | 5.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 64 | 14.61 | 330 | 309 | 0.31 / 124.39 | 6 | 21 |
2 | 7 | 2002.00 | 105 | 13.19 | 1661 | 2300 | 2.61 / 126.69 | 21 | 41 |
3 | 13 | 1788.96 | 36 | 13.67 | 1554 | 765 | 3.37 / 127.45 | 5 | 47 |
4 | 13 | 1043.76 | 36 | 14.01 | 1051 | 530 | 3.90 / 127.98 | 5 | 55 |
5 | 13 | 605.76 | 36 | 14.27 | 739 | 380 | 4.28 / 128.36 | 5 | 55 |
6 | 8 | 0.04 | 450 | 14.40 | 253 | 1639 | 5.92 / 130.00 | 6 | 63 |
Average= | 5.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 64 | 14.64 | 334 | 313 | 0.31 / 118.25 | 6 | 20 |
2 | 7 | 2003.32 | 105 | 13.19 | 1668 | 2310 | 2.62 / 120.56 | 20 | 41 |
3 | 13 | 1904.00 | 36 | 13.58 | 1616 | 790 | 3.41 / 121.35 | 5 | 46 |
4 | 13 | 1095.84 | 36 | 13.99 | 1094 | 551 | 3.96 / 121.90 | 5 | 55 |
5 | 13 | 653.60 | 36 | 14.24 | 774 | 397 | 4.36 / 122.30 | 5 | 56 |
6 | 13 | 50.92 | 36 | 14.69 | 300 | 159 | 4.52 / 122.45 | 5 | 46 |
7 | 8 | 0.16 | 450 | 14.40 | 251 | 1626 | 6.15 / 124.08 | 6 | 70 |
Average= | 5.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 64 | 14.67 | 314 | 295 | 0.29 / 112.18 | 6 | 19 |
2 | 7 | 2005.80 | 105 | 13.21 | 1669 | 2315 | 2.61 / 114.49 | 19 | 42 |
3 | 13 | 1796.04 | 36 | 13.68 | 1557 | 767 | 3.38 / 115.26 | 5 | 48 |
4 | 13 | 1046.52 | 36 | 14.01 | 1057 | 533 | 3.91 / 115.79 | 5 | 55 |
5 | 13 | 501.68 | 36 | 14.35 | 662 | 342 | 4.25 / 116.14 | 5 | 54 |
6 | 13 | 82.40 | 36 | 14.65 | 329 | 174 | 4.43 / 116.31 | 5 | 47 |
7 | 8 | -0.04 | 450 | 14.39 | 251 | 1625 | 6.05 / 117.93 | 6 | 61 |
Average= | 5.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 63 | 14.66 | 323 | 298 | 0.30 / 106.14 | 6 | 19 |
2 | 3 | 1012.24 | 1 | 14.56 | 1048 | 15 | 0.31 / 106.15 | 5 | 23 |
3 | 7 | 2006.44 | 105 | 13.22 | 1670 | 2318 | 2.63 / 108.47 | 23 | 42 |
4 | 13 | 1706.72 | 36 | 13.73 | 1499 | 741 | 3.37 / 109.21 | 5 | 49 |
5 | 13 | 972.52 | 36 | 14.07 | 1005 | 509 | 3.88 / 109.72 | 5 | 55 |
6 | 13 | 658.92 | 36 | 14.26 | 777 | 399 | 4.28 / 110.12 | 5 | 55 |
7 | 13 | 5.88 | 36 | 14.73 | 264 | 140 | 4.42 / 110.26 | 5 | 48 |
8 | 8 | 0.40 | 450 | 14.40 | 251 | 1626 | 6.05 / 111.88 | 8 | 65 |
Average= | 5.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 63 | 14.67 | 310 | 287 | 0.29 / 100.09 | 6 | 17 |
2 | 7 | 2005.96 | 106 | 13.24 | 1667 | 2340 | 2.63 / 102.43 | 17 | 42 |
3 | 13 | 1490.92 | 36 | 13.84 | 1362 | 679 | 3.30 / 103.11 | 5 | 51 |
4 | 13 | 1185.96 | 36 | 13.98 | 1148 | 578 | 3.88 / 103.68 | 5 | 54 |
5 | 13 | 611.80 | 36 | 14.29 | 740 | 381 | 4.26 / 104.07 | 5 | 55 |
6 | 13 | 59.72 | 36 | 14.70 | 306 | 162 | 4.43 / 104.23 | 5 | 46 |
7 | 8 | -0.08 | 450 | 14.42 | 248 | 1609 | 6.03 / 105.84 | 6 | 59 |
Average= | 5.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 63 | 14.70 | 312 | 289 | 0.29 / 94.09 | 6 | 17 |
2 | 7 | 2003.04 | 106 | 13.25 | 1669 | 2344 | 2.63 / 96.44 | 5 | 41 |
3 | 13 | 1909.32 | 36 | 13.62 | 1612 | 790 | 3.42 / 97.23 | 5 | 46 |
4 | 13 | 984.32 | 36 | 14.07 | 1014 | 514 | 3.94 / 97.74 | 5 | 55 |
5 | 13 | 451.76 | 36 | 14.39 | 619 | 321 | 4.26 / 98.06 | 5 | 53 |
6 | 13 | 24.16 | 36 | 14.73 | 274 | 145 | 4.40 / 98.21 | 5 | 46 |
7 | 8 | 0.08 | 450 | 14.42 | 246 | 1596 | 6.00 / 99.80 | 9 | 61 |
Average= | 5.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 63 | 14.71 | 309 | 286 | 0.29 / 88.15 | 6 | 15 |
2 | 7 | 2003.88 | 105 | 13.27 | 1670 | 2327 | 2.61 / 90.47 | 15 | 42 |
3 | 13 | 1448.72 | 36 | 13.86 | 1328 | 663 | 3.28 / 91.14 | 5 | 51 |
4 | 13 | 1237.84 | 36 | 13.95 | 1185 | 595 | 3.87 / 91.73 | 5 | 54 |
5 | 13 | 465.12 | 36 | 14.39 | 629 | 326 | 4.20 / 92.06 | 5 | 53 |
6 | 13 | 25.56 | 36 | 14.73 | 278 | 147 | 4.34 / 92.21 | 5 | 45 |
7 | 8 | 0.08 | 450 | 14.43 | 246 | 1597 | 5.94 / 93.80 | 6 | 63 |
Average= | 5.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 63 | 14.69 | 314 | 291 | 0.29 / 82.24 | 6 | 16 |
2 | 7 | 2005.04 | 105 | 13.29 | 1673 | 2335 | 2.63 / 84.58 | 5 | 42 |
3 | 13 | 1496.76 | 36 | 13.84 | 1368 | 682 | 3.31 / 85.26 | 5 | 51 |
4 | 13 | 982.20 | 36 | 14.08 | 1018 | 516 | 3.82 / 85.78 | 5 | 55 |
5 | 13 | 459.84 | 36 | 14.40 | 626 | 325 | 4.15 / 86.10 | 5 | 53 |
6 | 13 | 58.56 | 36 | 14.71 | 304 | 161 | 4.31 / 86.26 | 5 | 45 |
7 | 8 | 0.04 | 450 | 14.45 | 246 | 1600 | 5.91 / 87.86 | 6 | 62 |
Average= | 5.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 63 | 14.72 | 305 | 283 | 0.28 / 76.14 | 6 | 16 |
2 | 7 | 2001.28 | 105 | 13.30 | 1666 | 2327 | 2.61 / 78.47 | 16 | 43 |
3 | 13 | 1685.88 | 36 | 13.77 | 1484 | 736 | 3.35 / 79.20 | 5 | 49 |
4 | 13 | 1247.72 | 36 | 13.96 | 1200 | 603 | 3.95 / 79.81 | 5 | 55 |
5 | 13 | 560.16 | 36 | 14.32 | 709 | 366 | 4.31 / 80.17 | 5 | 56 |
6 | 13 | 43.96 | 36 | 14.73 | 296 | 157 | 4.47 / 80.33 | 5 | 46 |
7 | 8 | 0.08 | 450 | 14.44 | 250 | 1624 | 6.10 / 81.95 | 6 | 65 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 63 | 14.73 | 311 | 289 | 0.29 / 70.05 | 6 | 15 |
2 | 7 | 2006.84 | 105 | 13.30 | 1674 | 2338 | 2.63 / 72.39 | 15 | 43 |
3 | 13 | 1799.00 | 36 | 13.72 | 1562 | 772 | 3.40 / 73.16 | 5 | 48 |
4 | 13 | 1099.88 | 36 | 14.02 | 1104 | 557 | 3.96 / 73.72 | 5 | 56 |
5 | 13 | 556.40 | 36 | 14.31 | 706 | 364 | 4.32 / 74.08 | 5 | 57 |
6 | 13 | 50.04 | 36 | 14.71 | 303 | 160 | 4.48 / 74.24 | 5 | 47 |
7 | 8 | 0.08 | 450 | 14.43 | 249 | 1617 | 6.10 / 75.86 | 6 | 58 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 63 | 14.75 | 312 | 290 | 0.29 / 63.91 | 6 | 13 |
2 | 7 | 2008.96 | 105 | 13.31 | 1675 | 2341 | 2.63 / 66.25 | 13 | 43 |
3 | 13 | 1909.00 | 36 | 13.64 | 1626 | 798 | 3.43 / 67.05 | 5 | 47 |
4 | 13 | 1120.64 | 36 | 14.00 | 1120 | 564 | 3.99 / 67.62 | 5 | 56 |
5 | 13 | 569.00 | 36 | 14.31 | 715 | 368 | 4.36 / 67.98 | 5 | 56 |
6 | 13 | 99.92 | 36 | 14.69 | 338 | 179 | 4.54 / 68.16 | 5 | 46 |
7 | 8 | 0.44 | 450 | 14.45 | 246 | 1600 | 6.14 / 69.76 | 6 | 66 |
Average= | 5.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 63 | 14.77 | 304 | 283 | 0.28 / 57.85 | 6 | 13 |
2 | 7 | 2006.48 | 105 | 13.32 | 1676 | 2344 | 2.63 / 60.19 | 13 | 42 |
3 | 13 | 1797.88 | 36 | 13.75 | 1557 | 771 | 3.40 / 60.96 | 5 | 48 |
4 | 13 | 1102.88 | 36 | 14.03 | 1103 | 557 | 3.95 / 61.52 | 5 | 55 |
5 | 13 | 557.52 | 36 | 14.34 | 701 | 362 | 4.32 / 61.88 | 5 | 55 |
6 | 13 | 53.16 | 36 | 14.75 | 299 | 159 | 4.48 / 62.04 | 5 | 44 |
7 | 8 | 0.12 | 450 | 14.47 | 243 | 1582 | 6.06 / 63.62 | 6 | 62 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 61 | 14.79 | 305 | 275 | 0.28 / 51.78 | 6 | 13 |
2 | 3 | 1042.12 | 2 | 14.77 | 1075 | 32 | 0.31 / 51.81 | 5 | 44 |
3 | 7 | 2004.56 | 105 | 13.34 | 1674 | 2345 | 2.65 / 54.16 | 44 | 42 |
4 | 13 | 1476.88 | 36 | 13.87 | 1359 | 679 | 3.33 / 54.84 | 5 | 51 |
5 | 13 | 1159.16 | 36 | 14.00 | 1142 | 576 | 3.91 / 55.41 | 5 | 55 |
6 | 13 | 685.72 | 36 | 14.27 | 797 | 409 | 4.32 / 55.82 | 5 | 56 |
7 | 13 | 51.96 | 36 | 14.78 | 295 | 157 | 4.47 / 55.98 | 5 | 42 |
8 | 8 | 0.04 | 450 | 14.49 | 243 | 1584 | 6.06 / 57.56 | 6 | 64 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 61 | 14.82 | 299 | 270 | 0.27 / 45.69 | 6 | 11 |
2 | 7 | 2003.24 | 105 | 13.33 | 1676 | 2346 | 2.62 / 48.04 | 5 | 43 |
3 | 13 | 1902.96 | 36 | 13.68 | 1624 | 800 | 3.42 / 48.83 | 5 | 46 |
4 | 13 | 994.16 | 36 | 14.08 | 1027 | 521 | 3.94 / 49.36 | 5 | 56 |
5 | 13 | 657.04 | 36 | 14.27 | 777 | 399 | 4.34 / 49.75 | 5 | 56 |
6 | 13 | 36.28 | 36 | 14.79 | 286 | 152 | 4.49 / 49.91 | 5 | 43 |
7 | 8 | 0.16 | 450 | 14.46 | 246 | 1601 | 6.09 / 51.51 | 6 | 61 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 60 | 14.80 | 303 | 269 | 0.27 / 39.84 | 6 | 11 |
2 | 3 | 1012.68 | 1 | 14.64 | 1080 | 16 | 0.28 / 39.86 | 5 | 28 |
3 | 7 | 2004.12 | 105 | 13.35 | 1678 | 2352 | 2.64 / 42.21 | 28 | 43 |
4 | 13 | 1479.76 | 36 | 13.87 | 1362 | 680 | 3.32 / 42.89 | 5 | 51 |
5 | 13 | 939.04 | 36 | 14.11 | 984 | 500 | 3.82 / 43.39 | 5 | 56 |
6 | 13 | 396.76 | 36 | 14.47 | 569 | 296 | 4.11 / 43.69 | 5 | 49 |
7 | 13 | 35.52 | 36 | 14.80 | 281 | 150 | 4.26 / 43.84 | 6 | 42 |
8 | 8 | 0.12 | 450 | 14.47 | 243 | 1582 | 5.85 / 45.42 | 6 | 65 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 59 | 14.78 | 312 | 272 | 0.27 / 33.94 | 6 | 11 |
2 | 3 | 1017.64 | 1 | 14.68 | 1068 | 16 | 0.29 / 33.95 | 5 | 32 |
3 | 7 | 2001.12 | 106 | 13.34 | 1675 | 2369 | 2.66 / 36.32 | 32 | 43 |
4 | 13 | 1560.76 | 36 | 13.83 | 1416 | 705 | 3.36 / 37.03 | 5 | 51 |
5 | 13 | 822.48 | 36 | 14.16 | 906 | 462 | 3.82 / 37.49 | 5 | 56 |
6 | 13 | 506.96 | 36 | 14.38 | 654 | 339 | 4.16 / 37.83 | 5 | 53 |
7 | 13 | 63.72 | 36 | 14.76 | 306 | 163 | 4.32 / 37.99 | 5 | 43 |
8 | 8 | -0.04 | 450 | 14.48 | 243 | 1583 | 5.91 / 39.57 | 6 | 62 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 59 | 14.78 | 318 | 277 | 0.28 / 28.06 | 6 | 11 |
2 | 7 | 2001.28 | 105 | 13.35 | 1679 | 2354 | 2.63 / 30.42 | 5 | 43 |
3 | 13 | 1379.56 | 36 | 13.90 | 1296 | 649 | 3.28 / 31.07 | 5 | 51 |
4 | 13 | 1053.80 | 36 | 14.03 | 1078 | 544 | 3.82 / 31.61 | 5 | 56 |
5 | 13 | 270.16 | 36 | 14.56 | 480 | 252 | 4.08 / 31.86 | 5 | 47 |
6 | 13 | 34.20 | 36 | 14.78 | 290 | 154 | 4.23 / 32.02 | 5 | 42 |
7 | 8 | 0.08 | 450 | 14.44 | 254 | 1650 | 5.88 / 33.67 | 6 | 56 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 38 | 14.90 | 312 | 177 | 0.18 / 21.85 | 6 | 8 |
2 | 10 | 1009.80 | 10 | 14.72 | 1022 | 150 | 0.33 / 22.00 | 5 | 28 |
3 | 10 | 1047.60 | 7 | 14.66 | 1050 | 108 | 0.43 / 22.11 | 5 | 31 |
4 | 3 | 1071.20 | 4 | 14.74 | 1097 | 65 | 0.50 / 22.18 | 5 | 45 |
5 | 7 | 2001.08 | 105 | 13.35 | 1676 | 2349 | 2.85 / 24.53 | 45 | 42 |
6 | 13 | 1465.24 | 36 | 13.85 | 1345 | 671 | 3.52 / 25.20 | 5 | 51 |
7 | 13 | 848.48 | 36 | 14.13 | 928 | 472 | 3.99 / 25.67 | 5 | 56 |
8 | 13 | 415.92 | 36 | 14.43 | 596 | 310 | 4.30 / 25.98 | 5 | 50 |
9 | 13 | 43.28 | 36 | 14.78 | 295 | 157 | 4.46 / 26.14 | 5 | 42 |
10 | 8 | 0.08 | 450 | 14.44 | 254 | 1650 | 6.11 / 27.79 | 6 | 60 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 56 | 14.78 | 313 | 259 | 0.26 / 16.89 | 6 | 12 |
2 | 3 | 1030.00 | 1 | 14.72 | 1080 | 16 | 0.27 / 16.91 | 5 | 40 |
3 | 7 | 1504.88 | 106 | 13.64 | 1355 | 1959 | 2.23 / 18.86 | 40 | 43 |
4 | 13 | 1201.84 | 36 | 14.00 | 1163 | 586 | 2.82 / 19.45 | 5 | 50 |
5 | 13 | 772.84 | 36 | 14.18 | 869 | 444 | 3.26 / 19.89 | 5 | 53 |
6 | 13 | 121.96 | 36 | 14.73 | 354 | 188 | 3.45 / 20.08 | 5 | 42 |
7 | 8 | 0.08 | 450 | 14.47 | 245 | 1595 | 5.05 / 21.68 | 6 | 60 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 59 | 14.76 | 307 | 267 | 0.27 / 11.66 | 6 | 11 |
2 | 3 | 945.60 | -1 | 14.76 | 307 | 0 | 0.00 / 11.66 | 6 | 11 |
3 | 7 | 1507.88 | 106 | 13.61 | 1348 | 1945 | 2.21 / 13.60 | 11 | 44 |
4 | 13 | 1417.88 | 36 | 13.86 | 1297 | 647 | 2.86 / 14.25 | 5 | 47 |
5 | 13 | 829.44 | 36 | 14.13 | 904 | 460 | 3.32 / 14.71 | 5 | 54 |
6 | 13 | 153.20 | 36 | 14.68 | 376 | 199 | 3.52 / 14.91 | 5 | 44 |
7 | 13 | 11.40 | 36 | 14.80 | 260 | 139 | 3.66 / 15.05 | 5 | 42 |
8 | 8 | 0.08 | 450 | 14.42 | 244 | 1583 | 5.24 / 16.63 | 6 | 61 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 38 | 14.79 | 319 | 179 | 0.18 / 6.17 | 6 | 7 |
2 | 10 | 1008.84 | 12 | 14.59 | 1018 | 178 | 0.36 / 6.35 | 5 | 27 |
3 | 10 | 1043.80 | 6 | 14.55 | 1050 | 92 | 0.45 / 6.44 | 5 | 31 |
4 | 3 | 1046.08 | 2 | 14.69 | 1079 | 32 | 0.48 / 6.48 | 5 | 45 |
5 | 7 | 1501.84 | 106 | 13.55 | 1348 | 1936 | 2.42 / 8.41 | 45 | 44 |
6 | 13 | 1300.16 | 36 | 13.89 | 1229 | 615 | 3.03 / 9.03 | 5 | 50 |
7 | 13 | 864.76 | 36 | 14.08 | 931 | 472 | 3.50 / 9.50 | 5 | 55 |
8 | 13 | 93.92 | 36 | 14.71 | 329 | 174 | 3.68 / 9.67 | 5 | 42 |
9 | 13 | 20.32 | 36 | 14.74 | 267 | 142 | 3.82 / 9.81 | 5 | 42 |
10 | 8 | 0.08 | 450 | 14.42 | 243 | 1577 | 5.40 / 11.39 | 6 | 61 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 38 | 14.76 | 288 | 162 | 0.16 / 2.35 | 6 | 7 |
2 | 10 | 1016.24 | 11 | 14.37 | 1005 | 159 | 0.32 / 2.51 | 5 | 27 |
3 | 10 | 1047.56 | 6 | 14.41 | 1036 | 90 | 0.41 / 2.60 | 5 | 31 |
4 | 3 | 1091.12 | 4 | 14.47 | 1101 | 64 | 0.47 / 2.67 | 5 | 44 |
5 | 7 | 1023.52 | 105 | 13.69 | 1016 | 1460 | 1.93 / 4.13 | 44 | 49 |
6 | 13 | 104.36 | 36 | 14.63 | 324 | 171 | 2.10 / 4.30 | 5 | 42 |
7 | 13 | 24.20 | 36 | 14.68 | 259 | 137 | 2.24 / 4.43 | 5 | 42 |
8 | 8 | 0.12 | 450 | 14.39 | 241 | 1561 | 3.80 / 5.99 | 6 | 64 |
Average= | 3.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 89.08 | 38 | 14.43 | 284 | 156 | 0.16 / 0.16 | 6 | 18 |
2 | 7 | 97.24 | 106 | 14.33 | 284 | 431 | 0.59 / 0.59 | 18 | 22 |
3 | 13 | 57.72 | 36 | 14.63 | 257 | 135 | 0.72 / 0.72 | 6 | 24 |
4 | 13 | 15.76 | 36 | 14.69 | 227 | 120 | 0.84 / 0.84 | 6 | 26 |
5 | 8 | 0.32 | 450 | 14.49 | 207 | 1350 | 2.19 / 2.19 | 6 | 52 |
Average= | 2.19 (KJ/cycle) |