SIO Argo Site:
Pump Diagnostics Page   



Serial= 3246 WMO= 3902568

Return

←PreviousNext→

Cycle 38 GMT 29/12/2023 20:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 32 15.29 444 217 0.22 / 125.63 2 6
2 10 880.84 3 15.26 1511 69 0.29 / 125.70 2 8
3 7 1072.80 80 15.16 1691 2051 2.34 / 127.75 2 11
4 13 117.60 18 15.34 454 125 2.46 / 127.88 2 13
5 8 0.32 165 15.32 283 715 3.18 / 128.59 2 11
Average= 3.30
(KJ/cycle)

Cycle 37 GMT 20/12/2023 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 32 15.28 419 205 0.20 / 122.56 2 6
2 10 859.12 2 15.27 1472 45 0.25 / 122.61 2 8
3 7 1018.28 80 15.20 1621 1971 2.22 / 124.58 2 11
4 13 101.20 18 15.37 435 120 2.34 / 124.70 2 13
5 8 -0.04 165 15.34 284 719 3.06 / 125.42 2 10
Average= 3.30
(KJ/cycle)

Cycle 36 GMT 11/12/2023 0:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 32 15.29 418 205 0.20 / 119.35 2 6
2 10 870.56 3 15.26 1480 68 0.27 / 119.42 2 7
3 7 1101.24 80 15.15 1726 2092 2.36 / 121.51 2 11
4 13 127.36 18 15.34 465 128 2.49 / 121.64 2 14
5 8 0.20 165 15.32 283 715 3.21 / 122.36 2 16
Average= 3.31
(KJ/cycle)

Cycle 35 GMT 1/12/2023 14:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 32 15.32 420 206 0.21 / 116.10 2 6
2 10 859.72 3 15.28 1475 68 0.27 / 116.17 2 8
3 7 1060.04 81 15.19 1673 2058 2.33 / 118.23 2 11
4 13 109.20 18 15.37 441 122 2.45 / 118.35 2 14
5 13 24.04 18 15.37 320 89 2.54 / 118.44 2 12
6 8 0.08 165 15.34 281 711 3.25 / 119.15 2 14
Average= 3.31
(KJ/cycle)

Cycle 34 GMT 22/11/2023 4:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 32 15.21 443 216 0.22 / 113.14 2 5
2 10 878.00 3 15.22 1500 68 0.28 / 113.21 2 6
3 7 926.96 80 15.24 1500 1829 2.11 / 115.04 2 12
4 13 117.32 18 15.39 455 126 2.24 / 115.16 2 13
5 8 0.20 165 15.36 288 730 2.97 / 115.89 2 15
Average= 3.31
(KJ/cycle)

Cycle 33 GMT 12/11/2023 17:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 28 15.24 423 181 0.18 / 110.19 2 6
2 10 1029.76 2 15.22 1715 52 0.23 / 110.24 2 8
3 7 1032.68 81 15.03 1615 1966 2.20 / 112.21 2 11
4 8 0.16 165 15.25 284 715 2.91 / 112.93 2 13
Average= 3.32
(KJ/cycle)

Cycle 32 GMT 12/11/2023 12:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 28 15.28 421 180 0.18 / 107.33 2 5
2 10 1003.08 3 15.24 1673 76 0.26 / 107.41 2 6
3 7 997.12 80 15.07 1568 1890 2.15 / 109.30 2 11
4 8 0.20 165 15.27 283 713 2.86 / 110.01 2 9
Average= 3.33
(KJ/cycle)

Cycle 31 GMT 12/11/2023 7:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 28 15.29 442 189 0.19 / 104.18 2 5
2 10 1011.40 2 15.25 1692 52 0.24 / 104.23 2 6
3 7 1098.68 80 15.16 1714 2079 2.32 / 106.31 2 12
4 13 116.72 18 15.35 450 124 2.44 / 106.44 2 13
5 8 0.24 165 15.34 283 716 3.16 / 107.15 2 13
Average= 3.35
(KJ/cycle)

Cycle 30 GMT 6/11/2023 19:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 28 15.26 436 186 0.19 / 100.85 2 5
2 10 1009.56 3 15.22 1674 76 0.26 / 100.92 2 6
3 7 1189.56 81 15.12 1827 2238 2.50 / 103.16 2 12
4 13 91.44 18 15.37 418 116 2.62 / 103.28 2 14
5 8 0.08 165 15.34 282 714 3.33 / 103.99 2 11
Average= 3.35
(KJ/cycle)

Cycle 29 GMT 1/11/2023 8:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 28 15.25 445 190 0.19 / 96.79 2 5
2 10 1014.60 3 15.24 1678 77 0.27 / 96.87 2 6
3 7 1625.36 80 14.96 2369 2835 3.10 / 99.70 2 11
4 13 207.40 18 15.30 571 157 3.26 / 99.86 2 14
5 13 18.76 18 15.33 314 87 3.35 / 99.95 2 12
6 8 0.16 165 15.29 283 714 4.06 / 100.66 2 14
Average= 3.36
(KJ/cycle)

Cycle 28 GMT 29/10/2023 20: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 28 15.26 437 187 0.19 / 92.61 2 6
2 10 1019.72 2 15.24 1688 51 0.24 / 92.66 2 8
3 7 1713.36 80 14.94 2470 2952 3.19 / 95.61 2 10
4 13 265.48 18 15.27 649 178 3.37 / 95.79 2 14
5 13 52.32 18 15.32 363 100 3.47 / 95.89 2 14
6 8 0.16 165 15.29 282 711 4.18 / 96.60 2 14
Average= 3.33
(KJ/cycle)

Cycle 27 GMT 27/10/2023 11:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 28 15.26 416 178 0.18 / 88.60 2 5
2 10 1015.04 2 15.23 1686 51 0.23 / 88.65 2 7
3 7 1614.12 80 14.98 2351 2817 3.05 / 91.47 2 10
4 13 202.48 18 15.29 564 155 3.20 / 91.63 2 13
5 13 22.24 18 15.33 320 88 3.29 / 91.72 2 12
6 8 0.12 165 15.29 280 706 4.00 / 92.42 2 11
Average= 3.30
(KJ/cycle)

Cycle 26 GMT 26/10/2023 3:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 28 15.16 441 187 0.19 / 84.60 2 6
2 10 1009.56 2 15.16 1692 51 0.24 / 84.65 2 7
3 7 1619.52 80 14.98 2358 2826 3.06 / 87.48 2 10
4 13 195.48 18 15.30 553 152 3.22 / 87.63 2 13
5 13 23.64 18 15.33 321 89 3.31 / 87.72 2 13
6 8 0.16 165 15.30 280 707 4.01 / 88.43 2 14
Average= 3.28
(KJ/cycle)

Cycle 25 GMT 24/10/2023 19:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 10 15.20 442 67 0.07 / 80.55 2 5
2 7 1742.96 80 14.75 2501 2951 3.02 / 83.51 2 10
3 13 77.32 18 15.22 399 109 3.13 / 83.62 2 14
4 13 16.76 18 15.23 314 86 3.21 / 83.70 2 12
5 8 0.08 165 15.19 284 712 3.93 / 84.41 2 13
Average= 3.25
(KJ/cycle)

Cycle 24 GMT 24/10/2023 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 10 15.18 438 66 0.07 / 76.71 2 5
2 10 1737.00 2 15.04 2653 80 0.15 / 76.79 2 7
3 7 1689.44 80 14.77 2438 2881 3.03 / 79.67 2 10
4 13 67.32 18 15.23 387 106 3.13 / 79.78 2 14
5 8 0.20 165 15.21 283 710 3.84 / 80.49 2 15
Average= 3.22
(KJ/cycle)

Cycle 23 GMT 24/10/2023 2:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 10 15.19 439 67 0.07 / 72.87 2 5
2 10 1733.88 2 15.03 2657 80 0.15 / 72.95 2 7
3 7 1699.44 80 14.77 2443 2887 3.03 / 75.83 2 10
4 13 67.96 18 15.23 383 105 3.14 / 75.94 2 14
5 8 0.08 165 15.20 282 707 3.85 / 76.64 2 10
Average= 3.19
(KJ/cycle)

Cycle 22 GMT 23/10/2023 18:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 10 15.18 443 67 0.07 / 68.92 2 3
2 7 1743.52 81 14.74 2497 2981 3.05 / 71.90 2 10
3 13 79.28 18 15.22 402 110 3.16 / 72.01 2 14
4 13 16.24 18 15.23 310 85 3.24 / 72.09 2 12
5 8 0.12 165 15.19 281 704 3.95 / 72.80 2 12
Average= 3.17
(KJ/cycle)

Cycle 21 GMT 23/10/2023 10:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 10 15.17 444 67 0.07 / 65.07 2 3
2 7 1745.04 80 14.76 2503 2956 3.02 / 68.03 2 10
3 13 77.96 18 15.22 399 109 3.13 / 68.14 2 14
4 8 0.12 165 15.20 284 712 3.84 / 68.85 2 12
Average= 3.13
(KJ/cycle)

Cycle 20 GMT 23/10/2023 1:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 10 15.19 438 67 0.07 / 61.23 2 3
2 10 1700.76 3 15.01 2617 118 0.18 / 61.34 2 4
3 7 1673.28 80 14.77 2416 2855 3.04 / 64.20 2 10
4 13 55.68 18 15.23 370 101 3.14 / 64.30 2 14
5 8 0.12 165 15.20 282 707 3.85 / 65.01 2 15
Average= 3.10
(KJ/cycle)

Cycle 19 GMT 22/10/2023 17:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 10 15.18 441 67 0.07 / 57.38 2 5
2 7 1753.12 80 14.75 2512 2964 3.03 / 60.34 2 10
3 13 92.24 18 15.22 417 114 3.15 / 60.45 2 14
4 8 0.16 165 15.20 281 705 3.85 / 61.16 2 11
Average= 3.06
(KJ/cycle)

Cycle 18 GMT 22/10/2023 9:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 10 15.19 439 67 0.07 / 53.54 2 5
2 7 1740.20 80 14.76 2498 2950 3.02 / 56.49 2 10
3 13 91.08 18 15.22 419 115 3.13 / 56.60 2 14
4 8 0.16 165 15.20 282 707 3.84 / 57.31 2 14
Average= 3.02
(KJ/cycle)

Cycle 17 GMT 22/10/2023 1: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 10 15.19 442 67 0.07 / 49.70 2 5
2 7 1750.76 80 14.75 2506 2957 3.02 / 52.65 2 10
3 13 80.96 18 15.23 401 110 3.13 / 52.76 2 14
4 8 0.16 165 15.20 282 707 3.84 / 53.47 2 15
Average= 2.97
(KJ/cycle)

Cycle 16 GMT 21/10/2023 16:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 10 15.20 417 63 0.06 / 45.87 2 5
2 10 1704.28 2 15.03 2615 79 0.14 / 45.95 2 6
3 7 1683.64 80 14.78 2425 2867 3.01 / 48.82 2 10
4 13 60.88 18 15.23 374 103 3.11 / 48.92 2 14
5 8 0.20 165 15.20 282 707 3.82 / 49.63 2 16
Average= 2.92
(KJ/cycle)

Cycle 15 GMT 21/10/2023 8:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 10 15.20 420 64 0.06 / 42.05 2 3
2 10 1704.16 2 15.03 2595 78 0.14 / 42.13 2 4
3 7 1678.08 80 14.79 2420 2863 3.01 / 45.00 2 10
4 13 63.56 18 15.25 378 104 3.11 / 45.10 2 14
5 8 0.20 165 15.22 283 711 3.82 / 45.81 2 15
Average= 2.86
(KJ/cycle)

Cycle 14 GMT 21/10/2023 0:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.40 10 15.20 446 68 0.07 / 38.10 2 2
2 7 1740.24 81 14.78 2495 2987 3.05 / 41.08 2 10
3 13 71.12 18 15.25 391 107 3.16 / 41.19 2 14
4 13 17.88 18 15.25 316 87 3.25 / 41.28 2 11
5 8 0.08 165 15.21 284 713 3.96 / 41.99 2 14
Average= 2.80
(KJ/cycle)

Cycle 13 GMT 20/10/2023 16: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 10 15.22 434 66 0.07 / 34.26 2 3
2 10 1711.48 2 15.07 2638 80 0.15 / 34.34 2 4
3 7 1688.84 80 14.80 2432 2879 3.03 / 37.22 2 10
4 13 63.32 18 15.25 379 104 3.13 / 37.32 2 14
5 8 0.16 165 15.22 282 708 3.84 / 38.03 2 13
Average= 2.72
(KJ/cycle)

Cycle 12 GMT 20/10/2023 7:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 10 15.25 422 64 0.06 / 30.31 2 3
2 7 1748.64 80 14.80 2505 2966 3.03 / 33.28 2 10
3 13 77.28 18 15.26 403 111 3.14 / 33.39 2 14
4 13 17.44 18 15.26 316 87 3.23 / 33.47 2 12
5 8 0.08 165 15.23 285 716 3.94 / 34.19 2 13
Average= 2.63
(KJ/cycle)

Cycle 11 GMT 19/10/2023 23:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 15 15.25 438 100 0.10 / 26.74 2 6
2 7 1544.28 80 14.90 2259 2693 2.79 / 29.43 2 11
3 13 44.00 18 15.30 357 98 2.89 / 29.53 2 14
4 8 0.16 165 15.27 284 716 3.61 / 30.25 2 17
Average= 2.52
(KJ/cycle)

Cycle 10 GMT 19/10/2023 14: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 15 15.27 437 100 0.10 / 23.11 2 5
2 7 1538.84 81 14.92 2249 2718 2.82 / 25.83 2 11
3 13 40.08 18 15.31 348 96 2.91 / 25.93 2 15
4 8 0.16 165 15.27 283 713 3.63 / 26.64 2 17
Average= 2.42
(KJ/cycle)

Cycle 9 GMT 19/10/2023 5: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 15 15.34 420 97 0.10 / 19.55 2 6
2 7 1522.60 80 14.94 2222 2656 2.75 / 22.20 2 11
3 13 45.44 18 15.32 354 98 2.85 / 22.30 2 15
4 8 0.16 165 15.29 283 714 3.56 / 23.01 2 13
Average= 2.30
(KJ/cycle)

Cycle 8 GMT 18/10/2023 19:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 28 15.28 434 186 0.19 / 16.75 2 7
2 7 1028.16 81 15.20 1605 1976 2.16 / 18.73 2 13
3 8 0.12 165 15.37 285 723 2.88 / 19.45 2 13
Average= 2.16
(KJ/cycle)

Cycle 7 GMT 18/10/2023 3:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.24 28 15.31 436 187 0.19 / 13.93 2 6
2 7 1019.44 80 15.13 1590 1925 2.11 / 15.86 2 12
3 8 -0.08 165 15.33 280 708 2.82 / 16.56 2 16
Average= 2.07
(KJ/cycle)

Cycle 6 GMT 17/10/2023 19:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 42 15.32 431 277 0.28 / 11.83 2 6
2 7 562.76 80 15.29 997 1220 1.50 / 13.05 2 12
3 8 0.12 165 15.36 276 699 2.20 / 13.75 2 17
Average= 1.96
(KJ/cycle)

Cycle 5 GMT 17/10/2023 14:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 42 15.32 414 266 0.27 / 9.65 2 6
2 7 548.96 80 15.31 979 1199 1.47 / 10.85 2 11
3 8 0.16 165 15.37 276 700 2.17 / 11.55 2 12
Average= 1.92
(KJ/cycle)

Cycle 4 GMT 17/10/2023 9:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 42 15.35 434 280 0.28 / 7.46 2 5
2 7 562.92 80 15.32 997 1222 1.50 / 8.68 2 11
3 8 -0.08 165 15.38 278 705 2.21 / 9.38 2 15
Average= 1.88
(KJ/cycle)

Cycle 3 GMT 17/10/2023 4:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 51 15.35 420 329 0.33 / 5.71 2 5
2 7 283.72 80 15.39 631 777 1.11 / 6.48 2 10
3 8 0.04 165 15.40 273 694 1.80 / 7.18 2 16
Average= 1.79
(KJ/cycle)

Cycle 2 GMT 17/10/2023 1:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 51 15.36 425 333 0.33 / 3.91 2 5
2 7 284.96 80 15.39 634 781 1.11 / 4.69 2 10
3 8 0.08 165 15.40 270 686 1.80 / 5.38 2 17
Average= 1.79
(KJ/cycle)

Cycle 1 GMT 16/10/2023 22:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 51 15.44 403 317 0.32 / 2.13 2 4
2 7 274.72 80 15.43 616 760 1.08 / 2.89 2 8
3 8 -0.04 165 15.43 269 685 1.76 / 3.58 2 16
Average= 1.79
(KJ/cycle)

Cycle 0 GMT 16/10/2023 19:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 135.36 51 15.59 436 347 0.35 / 0.35 2 4
2 7 152.08 80 15.55 438 545 0.89 / 0.89 2 6
3 8 0.20 240 15.51 248 923 1.81 / 1.81 2 24
Average= 1.81
(KJ/cycle)