SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 31 | 14.84 | 433 | 199 | 0.20 / 86.49 | 5 | 5 |
2 | 7 | 2008.60 | 40 | 14.43 | 3282 | 1894 | 2.09 / 88.38 | 5 | 6 |
3 | 13 | 1420.16 | 20 | 14.50 | 2434 | 706 | 2.80 / 89.09 | 5 | 7 |
4 | 13 | 839.76 | 20 | 14.64 | 1579 | 462 | 3.26 / 89.55 | 5 | 9 |
5 | 13 | 132.76 | 20 | 14.86 | 488 | 145 | 3.41 / 89.69 | 5 | 7 |
6 | 8 | 0.08 | 259 | 14.87 | 276 | 1063 | 4.47 / 90.76 | 5 | 188 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 31 | 14.85 | 434 | 200 | 0.20 / 82.05 | 5 | 5 |
2 | 7 | 2009.84 | 40 | 14.42 | 3270 | 1886 | 2.09 / 83.94 | 5 | 6 |
3 | 13 | 1326.92 | 20 | 14.52 | 2297 | 667 | 2.75 / 84.60 | 5 | 9 |
4 | 13 | 865.36 | 20 | 14.62 | 1615 | 472 | 3.23 / 85.07 | 5 | 9 |
5 | 13 | 146.00 | 20 | 14.86 | 507 | 151 | 3.38 / 85.23 | 5 | 7 |
6 | 8 | 0.04 | 257 | 14.87 | 278 | 1062 | 4.44 / 86.29 | 5 | 145 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 31 | 14.85 | 441 | 203 | 0.20 / 77.64 | 5 | 5 |
2 | 7 | 2010.80 | 40 | 14.43 | 3284 | 1896 | 2.10 / 79.54 | 5 | 6 |
3 | 13 | 1323.20 | 20 | 14.53 | 2290 | 665 | 2.76 / 80.20 | 5 | 8 |
4 | 13 | 869.08 | 20 | 14.63 | 1618 | 473 | 3.24 / 80.68 | 5 | 10 |
5 | 13 | 82.44 | 20 | 14.88 | 405 | 121 | 3.36 / 80.80 | 5 | 6 |
6 | 8 | 0.08 | 257 | 14.88 | 275 | 1052 | 4.41 / 81.85 | 5 | 136 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 31 | 14.86 | 432 | 199 | 0.20 / 73.21 | 5 | 5 |
2 | 7 | 2005.08 | 40 | 14.43 | 3272 | 1889 | 2.09 / 75.10 | 5 | 6 |
3 | 13 | 1447.04 | 20 | 14.50 | 2475 | 718 | 2.81 / 75.81 | 5 | 7 |
4 | 13 | 774.24 | 20 | 14.67 | 1476 | 433 | 3.24 / 76.25 | 5 | 8 |
5 | 13 | 98.56 | 20 | 14.88 | 431 | 128 | 3.37 / 76.38 | 5 | 6 |
6 | 8 | 0.08 | 259 | 14.88 | 276 | 1064 | 4.43 / 77.44 | 5 | 186 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 31 | 14.86 | 439 | 202 | 0.20 / 68.83 | 5 | 5 |
2 | 7 | 2003.84 | 40 | 14.44 | 3280 | 1895 | 2.10 / 70.72 | 5 | 7 |
3 | 13 | 1322.64 | 20 | 14.53 | 2301 | 669 | 2.77 / 71.39 | 5 | 8 |
4 | 13 | 775.76 | 20 | 14.67 | 1483 | 435 | 3.20 / 71.83 | 5 | 9 |
5 | 13 | 94.80 | 20 | 14.89 | 419 | 125 | 3.33 / 71.95 | 5 | 7 |
6 | 8 | 0.20 | 257 | 14.88 | 277 | 1059 | 4.38 / 73.01 | 5 | 154 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 31 | 14.86 | 427 | 197 | 0.20 / 64.34 | 5 | 5 |
2 | 7 | 2003.72 | 40 | 14.44 | 3279 | 1894 | 2.09 / 66.23 | 5 | 6 |
3 | 13 | 1421.04 | 20 | 14.52 | 2437 | 708 | 2.80 / 66.94 | 5 | 8 |
4 | 13 | 837.20 | 20 | 14.65 | 1575 | 461 | 3.26 / 67.40 | 5 | 10 |
5 | 13 | 102.12 | 20 | 14.89 | 438 | 130 | 3.39 / 67.53 | 5 | 7 |
6 | 13 | 23.04 | 20 | 14.91 | 322 | 96 | 3.49 / 67.63 | 5 | 7 |
7 | 8 | 0.00 | 238 | 14.88 | 281 | 995 | 4.48 / 68.62 | 5 | 180 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 31 | 14.87 | 431 | 199 | 0.20 / 59.84 | 5 | 5 |
2 | 7 | 2002.32 | 40 | 14.44 | 3285 | 1897 | 2.10 / 61.74 | 5 | 5 |
3 | 13 | 1433.44 | 20 | 14.52 | 2457 | 714 | 2.81 / 62.46 | 5 | 7 |
4 | 13 | 840.72 | 20 | 14.65 | 1582 | 464 | 3.27 / 62.92 | 5 | 9 |
5 | 13 | 114.72 | 20 | 14.89 | 458 | 136 | 3.41 / 63.06 | 5 | 7 |
6 | 13 | 25.20 | 20 | 14.91 | 325 | 97 | 3.51 / 63.15 | 5 | 8 |
7 | 8 | 0.00 | 238 | 14.88 | 280 | 992 | 4.50 / 64.14 | 5 | 158 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 31 | 14.86 | 432 | 199 | 0.20 / 55.41 | 5 | 5 |
2 | 7 | 2004.16 | 40 | 14.43 | 3285 | 1896 | 2.10 / 57.30 | 5 | 6 |
3 | 13 | 1309.36 | 20 | 14.55 | 2281 | 664 | 2.76 / 57.97 | 5 | 8 |
4 | 13 | 839.44 | 20 | 14.65 | 1580 | 463 | 3.22 / 58.43 | 5 | 10 |
5 | 13 | 111.72 | 20 | 14.89 | 458 | 136 | 3.36 / 58.57 | 5 | 7 |
6 | 8 | 0.12 | 257 | 14.89 | 282 | 1079 | 4.44 / 59.65 | 5 | 152 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 31 | 14.87 | 436 | 201 | 0.20 / 50.96 | 5 | 5 |
2 | 7 | 2002.52 | 40 | 14.44 | 3271 | 1889 | 2.09 / 52.85 | 5 | 5 |
3 | 13 | 1399.16 | 20 | 14.54 | 2409 | 701 | 2.79 / 53.55 | 5 | 7 |
4 | 13 | 808.76 | 20 | 14.67 | 1534 | 450 | 3.24 / 54.00 | 5 | 10 |
5 | 13 | 97.44 | 20 | 14.90 | 430 | 128 | 3.37 / 54.13 | 5 | 7 |
6 | 8 | 0.08 | 259 | 14.89 | 280 | 1080 | 4.45 / 55.21 | 5 | 167 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 31 | 14.89 | 424 | 196 | 0.20 / 46.46 | 5 | 5 |
2 | 7 | 2006.04 | 40 | 14.45 | 3283 | 1898 | 2.09 / 48.36 | 5 | 5 |
3 | 13 | 1418.64 | 20 | 14.54 | 2428 | 706 | 2.80 / 49.07 | 5 | 7 |
4 | 13 | 836.44 | 20 | 14.67 | 1573 | 462 | 3.26 / 49.53 | 5 | 8 |
5 | 13 | 128.04 | 20 | 14.89 | 476 | 142 | 3.40 / 49.67 | 5 | 7 |
6 | 13 | 10.52 | 20 | 14.93 | 299 | 89 | 3.49 / 49.76 | 5 | 7 |
7 | 8 | 0.00 | 240 | 14.89 | 280 | 1001 | 4.49 / 50.76 | 5 | 160 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 31 | 14.89 | 434 | 200 | 0.20 / 41.97 | 5 | 5 |
2 | 7 | 2006.00 | 40 | 14.46 | 3275 | 1894 | 2.09 / 43.87 | 5 | 5 |
3 | 13 | 1420.92 | 20 | 14.55 | 2434 | 708 | 2.80 / 44.58 | 5 | 7 |
4 | 13 | 856.24 | 20 | 14.67 | 1600 | 469 | 3.27 / 45.05 | 5 | 8 |
5 | 13 | 83.48 | 20 | 14.92 | 409 | 122 | 3.39 / 45.17 | 5 | 6 |
6 | 13 | 18.24 | 20 | 14.93 | 310 | 93 | 3.49 / 45.26 | 5 | 7 |
7 | 8 | -0.16 | 242 | 14.90 | 279 | 1006 | 4.49 / 46.27 | 5 | 164 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 31 | 14.88 | 423 | 195 | 0.20 / 37.51 | 5 | 5 |
2 | 7 | 2002.68 | 40 | 14.46 | 3265 | 1888 | 2.08 / 39.40 | 5 | 5 |
3 | 13 | 1403.04 | 20 | 14.54 | 2418 | 703 | 2.79 / 40.10 | 5 | 7 |
4 | 13 | 812.24 | 20 | 14.68 | 1537 | 451 | 3.24 / 40.56 | 5 | 8 |
5 | 13 | 103.36 | 20 | 14.91 | 445 | 133 | 3.37 / 40.69 | 5 | 6 |
6 | 8 | 0.12 | 261 | 14.91 | 279 | 1086 | 4.46 / 41.77 | 5 | 145 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 31 | 14.89 | 433 | 200 | 0.20 / 33.06 | 5 | 5 |
2 | 7 | 2005.28 | 40 | 14.46 | 3272 | 1893 | 2.09 / 34.95 | 5 | 5 |
3 | 13 | 1423.24 | 20 | 14.55 | 2423 | 705 | 2.80 / 35.65 | 5 | 7 |
4 | 13 | 840.60 | 20 | 14.68 | 1570 | 461 | 3.26 / 36.12 | 5 | 9 |
5 | 13 | 115.32 | 20 | 14.91 | 456 | 136 | 3.39 / 36.25 | 5 | 7 |
6 | 8 | -0.04 | 261 | 14.91 | 274 | 1066 | 4.46 / 37.32 | 5 | 143 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 31 | 14.90 | 425 | 196 | 0.20 / 28.61 | 5 | 5 |
2 | 7 | 2003.08 | 40 | 14.47 | 3273 | 1894 | 2.09 / 30.51 | 5 | 5 |
3 | 13 | 1324.24 | 20 | 14.58 | 2286 | 667 | 2.76 / 31.18 | 5 | 7 |
4 | 13 | 860.52 | 20 | 14.68 | 1598 | 469 | 3.23 / 31.65 | 5 | 9 |
5 | 13 | 125.92 | 20 | 14.91 | 473 | 141 | 3.37 / 31.79 | 5 | 7 |
6 | 8 | 0.00 | 263 | 14.91 | 273 | 1071 | 4.44 / 32.86 | 5 | 167 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 30 | 14.91 | 419 | 187 | 0.19 / 24.24 | 5 | 5 |
2 | 3 | 1021.32 | 1 | 14.88 | 1818 | 27 | 0.21 / 24.27 | 5 | 5 |
3 | 7 | 2003.28 | 40 | 14.47 | 3260 | 1887 | 2.10 / 26.16 | 5 | 5 |
4 | 13 | 1417.32 | 20 | 14.56 | 2414 | 703 | 2.80 / 26.86 | 5 | 7 |
5 | 13 | 743.32 | 20 | 14.72 | 1403 | 413 | 3.22 / 27.27 | 5 | 8 |
6 | 13 | 83.24 | 20 | 14.94 | 378 | 113 | 3.33 / 27.39 | 5 | 6 |
7 | 8 | 0.04 | 263 | 14.93 | 263 | 1033 | 4.36 / 28.42 | 5 | 165 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 29 | 14.91 | 412 | 178 | 0.18 / 19.79 | 5 | 5 |
2 | 3 | 1049.88 | 1 | 14.85 | 1889 | 28 | 0.21 / 19.82 | 5 | 5 |
3 | 7 | 2004.32 | 40 | 14.47 | 3275 | 1896 | 2.10 / 21.72 | 5 | 5 |
4 | 13 | 1432.24 | 20 | 14.56 | 2433 | 708 | 2.81 / 22.42 | 5 | 7 |
5 | 13 | 848.92 | 20 | 14.69 | 1569 | 461 | 3.27 / 22.89 | 5 | 8 |
6 | 13 | 126.80 | 20 | 14.93 | 459 | 137 | 3.41 / 23.02 | 5 | 6 |
7 | 8 | 0.12 | 265 | 14.93 | 261 | 1033 | 4.44 / 24.06 | 5 | 157 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 31 | 14.92 | 418 | 193 | 0.19 / 15.52 | 5 | 5 |
2 | 3 | 940.52 | -1 | 15.30 | 0 | 0 | 0.00 / 15.52 | 5 | 5 |
3 | 7 | 2004.72 | 40 | 14.47 | 3266 | 1890 | 2.08 / 17.41 | 5 | 5 |
4 | 13 | 1309.76 | 20 | 14.59 | 2261 | 660 | 2.74 / 18.07 | 5 | 7 |
5 | 13 | 753.72 | 20 | 14.72 | 1435 | 422 | 3.17 / 18.49 | 5 | 8 |
6 | 13 | 77.40 | 20 | 14.95 | 385 | 115 | 3.28 / 18.61 | 5 | 7 |
7 | 8 | 0.04 | 263 | 14.93 | 257 | 1009 | 4.29 / 19.61 | 5 | 171 |
Average= | 3.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 29 | 14.92 | 432 | 187 | 0.19 / 11.67 | 5 | 5 |
2 | 3 | 1032.24 | 1 | 14.86 | 1865 | 28 | 0.21 / 11.70 | 5 | 5 |
3 | 7 | 1507.00 | 41 | 14.65 | 2532 | 1521 | 1.74 / 13.22 | 5 | 5 |
4 | 13 | 1204.52 | 20 | 14.68 | 2109 | 619 | 2.35 / 13.84 | 5 | 7 |
5 | 13 | 617.00 | 20 | 14.80 | 1230 | 364 | 2.72 / 14.20 | 5 | 8 |
6 | 13 | 22.88 | 20 | 14.99 | 306 | 92 | 2.81 / 14.29 | 5 | 7 |
7 | 8 | 0.12 | 259 | 14.95 | 266 | 1030 | 3.84 / 15.32 | 5 | 153 |
Average= | 3.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 29 | 14.91 | 416 | 180 | 0.18 / 7.88 | 5 | 5 |
2 | 7 | 1517.16 | 40 | 14.65 | 2557 | 1498 | 1.68 / 9.38 | 5 | 5 |
3 | 13 | 1210.20 | 20 | 14.68 | 2121 | 623 | 2.30 / 10.01 | 5 | 7 |
4 | 13 | 649.88 | 20 | 14.80 | 1272 | 377 | 2.68 / 10.38 | 5 | 7 |
5 | 13 | 32.52 | 20 | 14.98 | 316 | 95 | 2.77 / 10.48 | 5 | 6 |
6 | 8 | -0.12 | 261 | 14.96 | 258 | 1007 | 3.78 / 11.48 | 5 | 159 |
Average= | 2.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 31 | 14.93 | 410 | 190 | 0.19 / 4.10 | 5 | 5 |
2 | 3 | 938.56 | -1 | 15.30 | 0 | 0 | 0.00 / 4.10 | 5 | 5 |
3 | 7 | 1523.68 | 40 | 14.65 | 2568 | 1505 | 1.69 / 5.60 | 5 | 5 |
4 | 13 | 1225.96 | 20 | 14.67 | 2142 | 628 | 2.32 / 6.23 | 5 | 6 |
5 | 13 | 641.12 | 20 | 14.79 | 1265 | 374 | 2.70 / 6.60 | 5 | 7 |
6 | 13 | 32.88 | 20 | 14.98 | 323 | 97 | 2.79 / 6.70 | 5 | 6 |
7 | 8 | 0.04 | 261 | 14.95 | 257 | 1003 | 3.80 / 7.70 | 5 | 153 |
Average= | 2.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 31 | 15.09 | 397 | 186 | 0.19 / 1.67 | 5 | 5 |
2 | 3 | 960.64 | -1 | 15.30 | 0 | 0 | 0.00 / 1.67 | 5 | 5 |
3 | 7 | 985.72 | 40 | 14.78 | 1760 | 1041 | 1.23 / 2.71 | 5 | 5 |
4 | 13 | 44.16 | 20 | 15.01 | 331 | 99 | 1.33 / 2.81 | 5 | 5 |
5 | 8 | 0.04 | 291 | 14.98 | 251 | 1094 | 2.42 / 3.91 | 5 | 147 |
Average= | 1.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.36 | 30 | 15.22 | 428 | 195 | 0.20 / 0.20 | 5 | 5 |
2 | 7 | 132.88 | 41 | 15.19 | 438 | 273 | 0.47 / 0.47 | 5 | 5 |
3 | 13 | 13.92 | 20 | 15.20 | 259 | 79 | 0.55 / 0.55 | 5 | 5 |
4 | 8 | 0.08 | 263 | 15.16 | 236 | 941 | 1.49 / 1.49 | 5 | 169 |
Average= | 1.49 (KJ/cycle) |