SIO Argo Site:
Pump Diagnostics Page   



Serial= 3201 WMO= 3902297

Return

←PreviousNext→

Cycle 72 GMT 18/12/2024 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 30 15.11 461 209 0.21 / 315.05 2 4
2 7 2003.84 24 15.05 2845 1028 1.24 / 316.08 2 9
3 13 1904.56 25 14.91 2731 1018 2.25 / 317.09 2 15
4 13 1152.80 25 14.97 1819 681 2.94 / 317.77 2 17
5 13 440.96 25 15.13 919 348 3.28 / 318.12 2 16
6 13 25.20 25 15.22 371 141 3.42 / 318.26 2 16
7 8 -1.48 175 15.15 330 875 4.30 / 319.14 2 24
Average= 4.37
(KJ/cycle)

Cycle 71 GMT 8/12/2024 6: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 30 15.11 468 212 0.21 / 310.74 2 4
2 7 2008.24 24 15.05 2856 1032 1.24 / 311.78 2 7
3 13 1855.52 25 14.91 2669 995 2.24 / 312.77 2 12
4 13 1268.48 25 14.96 1959 733 2.97 / 313.50 2 14
5 13 420.72 25 15.14 870 329 3.30 / 313.83 2 17
6 13 29.84 25 15.22 374 142 3.44 / 313.97 2 17
7 8 -0.64 175 15.16 326 865 4.31 / 314.84 2 19
Average= 4.37
(KJ/cycle)

Cycle 70 GMT 28/11/2024 11: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 30 15.11 470 213 0.21 / 306.33 2 4
2 7 2011.72 25 15.03 2875 1080 1.29 / 307.41 2 7
3 13 1967.20 25 14.88 2793 1039 2.33 / 308.45 2 14
4 13 1209.52 25 14.97 1877 702 3.03 / 309.16 2 15
5 13 480.00 25 15.12 948 358 3.39 / 309.51 2 17
6 13 28.12 25 15.21 370 141 3.53 / 309.65 2 14
7 8 0.52 175 15.15 331 878 4.41 / 310.53 2 23
Average= 4.37
(KJ/cycle)

Cycle 69 GMT 18/11/2024 16:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 30 15.12 470 213 0.21 / 301.85 2 4
2 7 2009.16 25 15.05 2891 1088 1.30 / 302.94 2 8
3 13 1960.80 25 14.90 2795 1041 2.34 / 303.98 2 11
4 13 1405.88 25 14.93 2126 794 3.14 / 304.78 2 16
5 13 480.00 25 15.13 947 358 3.49 / 305.14 2 17
6 13 30.64 25 15.23 350 133 3.63 / 305.27 2 18
7 8 0.04 175 15.16 321 852 4.48 / 306.12 2 20
Average= 4.37
(KJ/cycle)

Cycle 68 GMT 8/11/2024 21:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 30 15.12 466 211 0.21 / 297.40 2 4
2 7 2005.92 24 15.05 2851 1030 1.24 / 298.43 2 7
3 13 1957.96 25 14.90 2787 1038 2.28 / 299.46 2 10
4 13 1353.04 25 14.94 2054 767 3.05 / 300.23 2 14
5 13 537.32 25 15.10 1045 394 3.44 / 300.63 2 17
6 13 18.48 25 15.22 352 134 3.57 / 300.76 2 15
7 8 1.04 175 15.17 332 881 4.46 / 301.64 2 21
Average= 4.37
(KJ/cycle)

Cycle 67 GMT 30/10/2024 3: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 30 15.12 461 209 0.21 / 292.97 2 3
2 7 2006.04 25 15.05 2860 1076 1.29 / 294.05 2 8
3 13 1904.96 25 14.90 2730 1017 2.30 / 295.06 2 12
4 13 1310.60 25 14.94 2024 756 3.06 / 295.82 2 15
5 13 449.52 25 15.13 935 354 3.41 / 296.17 2 17
6 13 22.96 25 15.22 359 137 3.55 / 296.31 2 17
7 8 -0.76 175 15.17 330 876 4.42 / 297.19 2 17
Average= 4.37
(KJ/cycle)

Cycle 66 GMT 20/10/2024 8: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 30 15.13 466 212 0.21 / 288.61 2 4
2 7 2004.40 24 15.05 2849 1029 1.24 / 289.64 2 7
3 13 1955.20 25 14.89 2785 1037 2.28 / 290.67 2 11
4 13 1192.24 25 14.98 1861 697 2.97 / 291.37 2 15
5 13 514.96 25 15.13 1000 378 3.35 / 291.75 2 17
6 13 21.20 25 15.24 351 134 3.49 / 291.88 2 17
7 8 -0.40 175 15.17 331 879 4.36 / 292.76 2 20
Average= 4.37
(KJ/cycle)

Cycle 65 GMT 10/10/2024 13:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 30 15.12 469 213 0.21 / 284.23 2 4
2 7 2002.84 25 15.04 2860 1075 1.29 / 285.30 2 6
3 13 1953.72 25 14.91 2783 1037 2.33 / 286.34 2 11
4 13 1247.48 25 14.98 1931 723 3.05 / 287.06 2 15
5 13 411.00 25 15.17 858 325 3.37 / 287.39 2 16
6 13 25.28 25 15.23 371 141 3.52 / 287.53 2 14
7 8 -0.24 175 15.18 326 866 4.38 / 288.40 2 20
Average= 4.37
(KJ/cycle)

Cycle 64 GMT 30/ 9/2024 18:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 30 15.14 479 218 0.22 / 279.81 2 3
2 7 2006.80 24 15.06 2856 1032 1.25 / 280.85 2 7
3 13 1957.96 25 14.90 2796 1042 2.29 / 281.89 2 10
4 13 1301.52 25 14.96 2011 752 3.04 / 282.64 2 15
5 13 449.24 25 15.16 935 354 3.40 / 282.99 2 16
6 13 32.16 25 15.23 379 144 3.54 / 283.14 2 14
7 8 0.80 175 15.18 330 877 4.42 / 284.01 2 19
Average= 4.37
(KJ/cycle)

Cycle 63 GMT 20/ 9/2024 23:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 30 15.14 449 204 0.20 / 275.43 2 3
2 7 2007.76 25 15.06 2859 1076 1.28 / 276.51 2 6
3 13 1958.96 25 14.90 2781 1036 2.32 / 277.54 2 11
4 13 1234.00 25 14.99 1911 716 3.03 / 278.26 2 13
5 13 404.64 25 15.17 870 330 3.36 / 278.59 2 16
6 13 26.00 25 15.24 359 137 3.50 / 278.73 2 12
7 8 -0.28 175 15.18 327 869 4.37 / 279.60 2 23
Average= 4.37
(KJ/cycle)

Cycle 62 GMT 11/ 9/2024 5: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 30 15.15 462 210 0.21 / 271.02 2 3
2 7 2005.64 25 15.06 2861 1077 1.29 / 272.09 2 7
3 13 1957.08 25 14.90 2786 1038 2.32 / 273.13 2 11
4 13 1242.36 25 14.99 1924 721 3.05 / 273.85 2 14
5 13 472.04 25 15.15 957 362 3.41 / 274.22 2 16
6 13 34.52 25 15.25 378 144 3.55 / 274.36 2 20
7 8 0.28 175 15.18 327 869 4.42 / 275.23 2 20
Average= 4.37
(KJ/cycle)

Cycle 61 GMT 1/ 9/2024 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 30 15.15 472 215 0.21 / 266.55 2 3
2 7 2009.72 25 15.07 2865 1079 1.29 / 267.63 2 6
3 13 1962.88 25 14.91 2788 1039 2.33 / 268.66 2 11
4 13 1260.28 25 14.99 1948 730 3.06 / 269.39 2 13
5 13 580.68 25 15.13 1100 416 3.48 / 269.81 2 17
6 13 27.40 25 15.26 368 140 3.62 / 269.95 2 15
7 8 -0.44 175 15.19 322 856 4.48 / 270.81 2 19
Average= 4.37
(KJ/cycle)

Cycle 60 GMT 22/ 8/2024 15:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 30 15.14 472 214 0.21 / 262.10 2 3
2 7 2003.36 25 15.08 2858 1077 1.29 / 263.18 2 10
3 13 1957.64 25 14.92 2785 1039 2.33 / 264.21 2 10
4 13 1244.08 25 15.00 1944 729 3.06 / 264.94 2 14
5 13 457.36 25 15.17 952 361 3.42 / 265.30 2 17
6 13 24.76 25 15.26 368 140 3.56 / 265.45 2 16
7 8 -1.36 175 15.21 333 886 4.45 / 266.33 2 20
Average= 4.37
(KJ/cycle)

Cycle 59 GMT 12/ 8/2024 20:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 30 15.14 463 210 0.21 / 257.71 2 3
2 7 2007.12 24 15.07 2861 1035 1.25 / 258.75 2 7
3 13 1959.64 25 14.92 2784 1038 2.28 / 259.79 2 11
4 13 1298.60 25 14.99 1994 747 3.03 / 260.53 2 14
5 13 444.68 25 15.17 903 342 3.37 / 260.88 2 16
6 13 30.00 25 15.26 352 134 3.51 / 261.01 2 17
7 8 -0.32 175 15.19 329 875 4.38 / 261.88 2 18
Average= 4.36
(KJ/cycle)

Cycle 58 GMT 3/ 8/2024 1:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 30 15.13 463 210 0.21 / 253.18 2 3
2 7 2005.16 25 15.05 2856 1075 1.28 / 254.25 2 9
3 13 1956.32 25 14.91 2780 1036 2.32 / 255.29 2 14
4 13 1291.16 25 14.98 1978 741 3.06 / 256.03 2 13
5 13 445.52 25 15.18 898 341 3.40 / 256.37 2 16
6 13 40.20 25 15.26 354 135 3.54 / 256.50 2 16
7 13 16.84 25 15.23 341 130 3.67 / 256.63 2 16
8 8 0.84 175 15.18 327 869 4.54 / 257.50 2 22
Average= 4.36
(KJ/cycle)

Cycle 57 GMT 24/ 7/2024 6:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 30 15.13 454 206 0.21 / 248.67 2 3
2 7 2002.16 24 15.07 2861 1035 1.24 / 249.70 2 6
3 13 1901.88 25 14.94 2711 1013 2.25 / 250.72 2 11
4 13 1256.12 25 15.00 1962 736 2.99 / 251.45 2 15
5 13 411.40 25 15.19 888 337 3.33 / 251.79 2 17
6 13 50.88 25 15.25 407 155 3.48 / 251.94 2 16
7 13 20.00 25 15.24 362 138 3.62 / 252.08 2 16
8 8 -2.52 175 15.18 333 885 4.50 / 252.97 2 19
Average= 4.36
(KJ/cycle)

Cycle 56 GMT 14/ 7/2024 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 30 15.14 459 208 0.21 / 244.13 2 3
2 7 2003.80 24 15.08 2851 1032 1.24 / 245.16 2 8
3 13 1959.44 25 14.93 2785 1040 2.28 / 246.20 2 11
4 13 1303.00 25 15.00 1998 749 3.03 / 246.95 2 14
5 13 457.12 25 15.18 916 348 3.38 / 247.29 2 16
6 13 63.00 25 15.27 410 157 3.53 / 247.45 2 16
7 13 27.44 25 15.24 367 140 3.67 / 247.59 2 16
8 8 0.12 175 15.19 328 872 4.54 / 248.46 2 18
Average= 4.36
(KJ/cycle)

Cycle 55 GMT 4/ 7/2024 17:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 30 15.15 449 204 0.20 / 239.46 2 3
2 7 2010.60 25 15.09 2861 1079 1.28 / 240.54 2 6
3 13 1963.28 25 14.93 2816 1051 2.33 / 241.59 2 11
4 13 1268.20 25 15.01 1981 743 3.08 / 242.33 2 15
5 13 576.16 25 15.16 1104 418 3.50 / 242.75 2 16
6 13 57.24 25 15.26 408 156 3.65 / 242.91 2 16
7 13 23.56 25 15.25 362 138 3.79 / 243.04 2 16
8 8 0.60 175 15.20 328 872 4.66 / 243.92 2 22
Average= 4.36
(KJ/cycle)

Cycle 54 GMT 24/ 6/2024 22:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 30 15.17 476 217 0.22 / 234.93 2 3
2 7 2007.72 24 15.09 2864 1037 1.25 / 235.97 2 9
3 13 1907.60 25 14.94 2724 1017 2.27 / 236.99 2 11
4 13 1264.84 25 15.02 1980 743 3.01 / 237.73 2 15
5 13 427.60 25 15.20 908 345 3.36 / 238.08 2 16
6 13 54.16 25 15.28 409 156 3.52 / 238.23 2 15
7 13 19.00 25 15.26 360 137 3.65 / 238.37 2 14
8 8 -0.28 175 15.20 332 883 4.54 / 239.25 2 20
Average= 4.35
(KJ/cycle)

Cycle 53 GMT 15/ 6/2024 3:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 30 15.15 442 201 0.20 / 230.43 2 3
2 7 2003.72 24 15.08 2868 1038 1.24 / 231.46 2 6
3 13 1955.08 25 14.93 2784 1039 2.28 / 232.50 2 11
4 13 1228.92 25 15.02 1907 716 2.99 / 233.22 2 14
5 13 428.20 25 15.20 897 341 3.33 / 233.56 2 17
6 13 45.32 25 15.27 395 151 3.49 / 233.71 2 16
7 13 20.28 25 15.26 359 137 3.62 / 233.85 2 17
8 8 -1.04 175 15.21 327 870 4.49 / 234.72 2 19
Average= 4.35
(KJ/cycle)

Cycle 52 GMT 5/ 6/2024 8:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 30 15.18 440 200 0.20 / 225.84 2 3
2 7 2003.32 25 15.08 2860 1078 1.28 / 226.92 2 7
3 13 1954.76 25 14.94 2799 1045 2.32 / 227.96 2 11
4 13 1221.08 25 15.03 1920 721 3.05 / 228.68 2 14
5 13 485.04 25 15.18 987 375 3.42 / 229.06 2 17
6 13 43.88 25 15.28 402 154 3.57 / 229.21 2 14
7 13 20.96 25 15.26 368 140 3.71 / 229.35 2 16
8 8 -2.36 175 15.21 328 873 4.59 / 230.22 2 22
Average= 4.34
(KJ/cycle)

Cycle 51 GMT 26/ 5/2024 13:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 30 15.17 440 200 0.20 / 221.36 2 3
2 7 2006.96 25 15.09 2869 1082 1.28 / 222.44 2 6
3 13 1958.28 25 14.93 2793 1042 2.33 / 223.48 2 11
4 13 1245.68 25 15.04 1935 728 3.05 / 224.21 2 15
5 13 455.16 25 15.21 933 355 3.41 / 224.56 2 16
6 13 47.04 25 15.28 390 149 3.56 / 224.71 2 14
7 13 25.08 25 15.26 362 138 3.69 / 224.85 2 14
8 8 0.52 165 15.22 313 786 4.48 / 225.64 2 21
Average= 4.34
(KJ/cycle)

Cycle 50 GMT 16/ 5/2024 18:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 30 15.15 442 201 0.20 / 216.89 2 3
2 7 2011.60 24 15.09 2853 1033 1.23 / 217.93 2 7
3 13 1964.28 25 14.94 2808 1049 2.28 / 218.98 2 11
4 13 1251.28 25 15.03 1963 738 3.02 / 219.71 2 14
5 13 450.76 25 15.21 941 358 3.38 / 220.07 2 16
6 13 49.80 25 15.27 396 151 3.53 / 220.22 2 15
7 13 27.68 25 15.26 365 139 3.67 / 220.36 2 15
8 8 0.60 165 15.22 317 796 4.46 / 221.16 2 21
Average= 4.34
(KJ/cycle)

Cycle 49 GMT 6/ 5/2024 23:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 30 15.15 453 206 0.21 / 212.42 2 3
2 7 2009.28 24 15.08 2854 1033 1.24 / 213.45 2 7
3 13 1960.00 25 14.94 2784 1040 2.28 / 214.49 2 11
4 13 1254.40 25 15.02 1960 736 3.01 / 215.23 2 16
5 13 477.96 25 15.18 972 369 3.38 / 215.60 2 17
6 13 39.76 25 15.27 387 148 3.53 / 215.75 2 16
7 13 16.16 25 15.26 352 134 3.67 / 215.88 2 15
8 8 0.00 165 15.21 324 813 4.48 / 216.69 2 19
Average= 4.33
(KJ/cycle)

Cycle 48 GMT 27/ 4/2024 4:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 30 15.16 439 200 0.20 / 207.97 2 3
2 7 2010.56 25 15.07 2858 1077 1.28 / 209.05 2 7
3 13 1909.40 25 14.95 2726 1019 2.30 / 210.07 2 11
4 13 1204.44 25 15.02 1898 713 3.01 / 210.78 2 14
5 13 376.72 25 15.22 842 320 3.33 / 211.10 2 16
6 13 48.56 25 15.27 393 150 3.48 / 211.25 2 15
7 13 17.40 25 15.26 348 133 3.61 / 211.38 2 17
8 8 -0.12 165 15.20 331 830 4.44 / 212.21 2 17
Average= 4.33
(KJ/cycle)

Cycle 47 GMT 17/ 4/2024 9:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 30 15.18 443 202 0.20 / 203.38 2 3
2 7 2011.24 25 15.10 2857 1079 1.28 / 204.46 2 9
3 13 1964.16 25 14.95 2793 1044 2.32 / 205.51 2 11
4 13 1297.48 25 15.03 1990 748 3.07 / 206.25 2 14
5 13 561.64 25 15.18 1085 412 3.48 / 206.66 2 16
6 13 60.12 25 15.27 414 158 3.64 / 206.82 2 16
7 13 22.32 25 15.26 363 138 3.78 / 206.96 2 16
8 8 1.44 165 15.22 323 811 4.59 / 207.77 2 19
Average= 4.33
(KJ/cycle)

Cycle 46 GMT 7/ 4/2024 14:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 30 15.18 454 207 0.21 / 198.85 2 3
2 7 2013.56 25 15.09 2859 1079 1.29 / 199.92 2 6
3 13 1968.48 25 14.95 2810 1050 2.34 / 200.97 2 13
4 13 1188.28 25 15.05 1889 711 3.05 / 201.69 2 15
5 13 509.00 25 15.19 1025 389 3.44 / 202.07 2 16
6 13 53.32 25 15.29 406 155 3.59 / 202.23 2 16
7 13 21.36 25 15.27 361 138 3.73 / 202.37 2 16
8 8 0.40 165 15.22 324 814 4.54 / 203.18 2 16
Average= 4.32
(KJ/cycle)

Cycle 45 GMT 28/ 3/2024 19:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 30 15.17 483 220 0.22 / 194.30 2 3
2 7 2004.16 25 15.10 2853 1077 1.30 / 195.38 2 9
3 13 1954.52 25 14.94 2810 1050 2.35 / 196.43 2 12
4 13 1225.56 25 15.04 1934 727 3.07 / 197.16 2 13
5 13 454.72 25 15.20 947 360 3.43 / 197.52 2 16
6 13 41.80 25 15.29 396 151 3.58 / 197.67 2 15
7 13 13.72 25 15.28 355 136 3.72 / 197.80 2 15
8 8 -1.48 165 15.23 332 834 4.55 / 198.64 2 20
Average= 4.32
(KJ/cycle)

Cycle 44 GMT 19/ 3/2024 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 30 15.18 446 203 0.20 / 189.67 2 3
2 7 2009.24 25 15.11 2862 1081 1.28 / 190.75 2 10
3 13 1963.64 25 14.96 2823 1056 2.34 / 191.81 2 12
4 13 1312.08 25 15.02 2043 767 3.11 / 192.57 2 14
5 13 467.16 25 15.21 967 368 3.47 / 192.94 2 16
6 13 49.00 25 15.29 406 155 3.63 / 193.10 2 16
7 13 19.52 25 15.28 365 139 3.77 / 193.24 2 15
8 8 0.76 165 15.23 338 849 4.62 / 194.08 2 22
Average= 4.31
(KJ/cycle)

Cycle 43 GMT 9/ 3/2024 5:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 30 15.19 468 213 0.21 / 185.08 2 3
2 7 2011.12 25 15.11 2860 1080 1.29 / 186.16 2 6
3 13 1962.96 25 14.97 2792 1045 2.34 / 187.20 2 11
4 13 1303.28 25 15.05 2015 758 3.10 / 187.96 2 15
5 13 502.08 25 15.21 1012 385 3.48 / 188.34 2 16
6 13 36.68 25 15.31 388 149 3.63 / 188.49 2 14
7 13 12.20 25 15.30 354 135 3.77 / 188.63 2 14
8 8 -0.28 165 15.25 333 838 4.60 / 189.47 2 19
Average= 4.31
(KJ/cycle)

Cycle 42 GMT 28/ 2/2024 10:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 30 15.20 457 208 0.21 / 180.58 2 4
2 7 2007.20 25 15.12 2869 1084 1.29 / 181.67 2 6
3 13 1962.12 25 14.96 2801 1048 2.34 / 182.72 2 12
4 13 1312.80 25 15.03 2032 764 3.10 / 183.48 2 15
5 13 507.60 25 15.21 1019 387 3.49 / 183.87 2 17
6 13 41.60 25 15.28 400 153 3.64 / 184.02 2 16
7 8 -1.80 165 15.24 335 842 4.49 / 184.86 2 16
Average= 4.30
(KJ/cycle)

Cycle 41 GMT 18/ 2/2024 15:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 30 15.18 453 206 0.21 / 176.26 2 3
2 7 2006.20 24 15.11 2860 1037 1.24 / 177.30 2 7
3 13 1957.20 25 14.96 2792 1044 2.29 / 178.34 2 12
4 13 1235.68 25 15.05 1910 719 3.01 / 179.06 2 15
5 13 405.80 25 15.23 881 335 3.34 / 179.40 2 16
6 13 42.20 25 15.30 403 154 3.50 / 179.55 2 15
7 8 -1.72 165 15.26 328 826 4.32 / 180.38 2 19
Average= 4.29
(KJ/cycle)

Cycle 40 GMT 8/ 2/2024 20:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 30 15.18 452 206 0.21 / 171.68 2 3
2 7 2012.12 25 15.10 2871 1084 1.29 / 172.77 2 6
3 13 1962.68 25 14.96 2811 1051 2.34 / 173.82 2 11
4 13 1282.16 25 15.03 1999 751 3.09 / 174.57 2 14
5 13 440.96 25 15.22 926 352 3.44 / 174.92 2 16
6 13 55.44 25 15.29 409 156 3.60 / 175.08 2 13
7 13 17.04 25 15.29 359 137 3.74 / 175.21 2 21
8 8 0.40 165 15.24 334 840 4.58 / 176.05 2 22
Average= 4.29
(KJ/cycle)

Cycle 39 GMT 30/ 1/2024 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 30 15.19 443 202 0.20 / 167.20 2 3
2 7 2008.52 24 15.11 2859 1037 1.24 / 168.24 2 11
3 13 1963.56 25 14.95 2793 1044 2.28 / 169.28 2 12
4 13 1195.28 25 15.06 1891 712 2.99 / 170.00 2 15
5 13 424.44 25 15.22 905 344 3.34 / 170.34 2 16
6 13 55.08 25 15.29 414 158 3.50 / 170.50 2 15
7 13 21.12 25 15.28 367 140 3.64 / 170.64 2 16
8 8 -1.68 165 15.23 333 837 4.47 / 171.48 2 19
Average= 4.29
(KJ/cycle)

Cycle 38 GMT 20/ 1/2024 5: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 30 15.18 456 208 0.21 / 162.68 2 3
2 7 2004.60 24 15.11 2853 1035 1.24 / 163.72 2 8
3 13 1956.76 25 14.96 2789 1043 2.29 / 164.76 2 14
4 13 1289.16 25 15.04 1974 742 3.03 / 165.50 2 14
5 13 496.88 25 15.23 997 380 3.41 / 165.88 2 17
6 13 68.72 25 15.30 432 165 3.57 / 166.05 2 16
7 13 21.00 25 15.28 360 138 3.71 / 166.18 2 16
8 8 -0.28 165 15.24 325 817 4.53 / 167.00 2 20
Average= 4.28
(KJ/cycle)

Cycle 37 GMT 10/ 1/2024 9:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 30 15.19 466 212 0.21 / 158.12 2 4
2 7 2004.12 25 15.10 2850 1076 1.29 / 159.20 2 7
3 13 1957.16 25 14.95 2782 1040 2.33 / 160.24 2 10
4 13 1235.64 25 15.06 1922 724 3.05 / 160.96 2 15
5 13 493.48 25 15.21 990 376 3.43 / 161.34 2 16
6 13 59.12 25 15.30 417 160 3.59 / 161.50 2 15
7 13 18.80 25 15.29 361 138 3.73 / 161.64 2 17
8 8 0.64 165 15.23 333 837 4.56 / 162.47 2 22
Average= 4.28
(KJ/cycle)

Cycle 36 GMT 31/12/2023 14:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 29 15.19 455 200 0.20 / 153.50 2 4
2 7 2008.44 25 15.11 2852 1077 1.28 / 154.58 2 7
3 13 1959.68 25 14.97 2794 1046 2.32 / 155.63 2 11
4 13 1297.88 25 15.05 1998 752 3.08 / 156.38 2 14
5 13 500.48 25 15.21 1015 386 3.46 / 156.76 2 17
6 13 63.32 25 15.30 417 160 3.62 / 156.92 2 17
7 13 19.80 25 15.28 365 139 3.76 / 157.06 2 17
8 8 0.96 165 15.24 338 850 4.61 / 157.91 2 19
Average= 4.27
(KJ/cycle)

Cycle 35 GMT 21/12/2023 19:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 29 15.19 470 207 0.21 / 149.03 2 4
2 7 2009.12 25 15.11 2871 1085 1.29 / 150.11 2 7
3 13 1962.64 25 14.97 2789 1044 2.34 / 151.16 2 11
4 13 1183.28 25 15.08 1854 699 3.03 / 151.86 2 16
5 13 358.64 25 15.25 809 308 3.34 / 152.16 2 15
6 13 73.44 25 15.31 433 166 3.51 / 152.33 2 13
7 13 41.48 25 15.29 387 148 3.66 / 152.48 2 20
8 8 -0.52 165 15.24 328 825 4.48 / 153.30 2 19
Average= 4.26
(KJ/cycle)

Cycle 34 GMT 12/12/2023 0:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 29 15.19 456 201 0.20 / 144.51 2 3
2 7 2008.68 24 15.11 2860 1037 1.24 / 145.55 2 7
3 13 1907.64 25 14.99 2725 1021 2.26 / 146.57 2 13
4 13 1195.04 25 15.07 1895 714 2.97 / 147.28 2 16
5 13 511.52 25 15.22 1028 391 3.36 / 147.67 2 16
6 13 74.60 25 15.31 439 168 3.53 / 147.84 2 16
7 13 42.60 25 15.30 391 150 3.68 / 147.99 2 16
8 8 -0.04 165 15.25 330 830 4.51 / 148.82 2 20
Average= 4.25
(KJ/cycle)

Cycle 33 GMT 2/12/2023 5:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 29 15.20 450 198 0.20 / 139.92 2 3
2 7 2004.96 25 15.12 2862 1082 1.28 / 141.00 2 6
3 13 1956.92 25 14.98 2789 1044 2.32 / 142.05 2 12
4 13 1228.24 25 15.08 1909 720 3.04 / 142.77 2 14
5 13 536.72 25 15.22 1060 403 3.45 / 143.17 2 17
6 13 79.00 25 15.30 441 169 3.62 / 143.34 2 16
7 13 44.96 25 15.30 396 151 3.77 / 143.49 2 16
8 8 -0.76 165 15.25 326 820 4.59 / 144.31 2 17
Average= 4.24
(KJ/cycle)

Cycle 32 GMT 22/11/2023 10:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 29 15.19 450 198 0.20 / 135.36 2 3
2 7 2002.96 25 15.13 2846 1076 1.27 / 136.44 2 8
3 13 1953.16 25 14.98 2783 1042 2.32 / 137.48 2 15
4 13 1244.20 25 15.07 1926 726 3.04 / 138.21 2 15
5 13 462.80 25 15.25 952 363 3.41 / 138.57 2 16
6 13 71.36 25 15.33 434 166 3.57 / 138.74 2 16
7 13 41.48 25 15.31 394 151 3.72 / 138.89 2 17
8 8 0.08 165 15.26 331 833 4.56 / 139.72 2 17
Average= 4.23
(KJ/cycle)

Cycle 31 GMT 12/11/2023 15:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 29 15.20 458 202 0.20 / 130.84 2 3
2 7 2009.48 25 15.14 2862 1083 1.29 / 131.92 2 6
3 13 1961.36 25 15.00 2790 1046 2.33 / 132.97 2 11
4 13 1199.24 25 15.08 1878 708 3.04 / 133.68 2 15
5 13 457.52 25 15.24 943 359 3.40 / 134.04 2 16
6 13 74.24 25 15.32 431 165 3.56 / 134.20 2 16
7 13 44.92 25 15.31 388 149 3.71 / 134.35 2 16
8 8 1.36 165 15.26 323 813 4.53 / 135.16 2 22
Average= 4.22
(KJ/cycle)

Cycle 30 GMT 2/11/2023 19:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 30 15.20 454 207 0.21 / 126.32 2 3
2 7 2004.00 24 15.14 2847 1034 1.24 / 127.35 2 10
3 13 1956.44 25 14.99 2778 1041 2.28 / 128.39 2 11
4 13 1193.96 25 15.09 1895 715 3.00 / 129.11 2 15
5 13 523.72 25 15.23 1044 398 3.39 / 129.51 2 17
6 13 44.68 25 15.32 395 151 3.55 / 129.66 2 15
7 13 22.44 25 15.31 366 140 3.69 / 129.80 2 15
8 8 0.40 165 15.26 334 841 4.53 / 130.64 2 22
Average= 4.21
(KJ/cycle)

Cycle 29 GMT 24/10/2023 0:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.24 30 15.23 466 213 0.21 / 121.85 2 3
2 7 2009.84 25 15.13 2858 1081 1.29 / 122.93 2 7
3 13 1961.60 25 14.98 2792 1046 2.34 / 123.98 2 12
4 13 1151.68 25 15.11 1815 686 3.03 / 124.66 2 15
5 13 372.28 25 15.26 835 319 3.34 / 124.98 2 16
6 13 50.28 25 15.31 411 157 3.50 / 125.14 2 17
7 13 23.08 25 15.30 372 142 3.64 / 125.28 2 15
8 8 -2.56 165 15.25 330 830 4.47 / 126.11 2 17
Average= 4.20
(KJ/cycle)

Cycle 28 GMT 14/10/2023 5:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 30 15.23 469 214 0.21 / 117.39 2 3
2 7 2004.80 24 15.14 2863 1040 1.25 / 118.43 2 7
3 13 1956.92 25 14.99 2790 1046 2.30 / 119.47 2 14
4 13 1238.56 25 15.10 1929 728 3.03 / 120.20 2 15
5 13 393.60 25 15.27 844 322 3.35 / 120.52 2 16
6 13 37.68 25 15.33 391 150 3.50 / 120.67 2 17
7 13 17.40 25 15.33 360 138 3.64 / 120.81 2 14
8 8 -2.64 165 15.28 328 827 4.47 / 121.64 2 22
Average= 4.19
(KJ/cycle)

Cycle 27 GMT 4/10/2023 10:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 29 15.22 450 199 0.20 / 112.88 2 3
2 7 2003.76 24 15.14 2852 1036 1.23 / 113.92 2 7
3 13 1954.04 25 15.00 2786 1045 2.28 / 114.96 2 12
4 13 1241.08 25 15.09 1924 726 3.01 / 115.69 2 14
5 13 463.80 25 15.25 961 366 3.37 / 116.05 2 17
6 13 46.24 25 15.34 402 154 3.53 / 116.21 2 15
7 13 23.68 25 15.31 369 141 3.67 / 116.35 2 17
8 8 0.20 165 15.26 327 823 4.49 / 117.17 2 23
Average= 4.18
(KJ/cycle)

Cycle 26 GMT 24/ 9/2023 15:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 29 15.24 454 201 0.20 / 108.39 2 3
2 7 2002.68 24 15.14 2856 1038 1.24 / 109.43 2 7
3 13 1953.76 25 14.99 2783 1043 2.28 / 110.47 2 10
4 13 1231.52 25 15.09 1918 724 3.00 / 111.19 2 14
5 13 497.12 25 15.24 992 378 3.38 / 111.57 2 17
6 13 38.52 25 15.33 393 151 3.53 / 111.72 2 16
7 13 19.80 25 15.32 367 141 3.67 / 111.86 2 17
8 8 -1.92 165 15.26 326 821 4.49 / 112.68 2 18
Average= 4.17
(KJ/cycle)

Cycle 25 GMT 14/ 9/2023 20:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 29 15.23 453 200 0.20 / 104.06 2 3
2 7 2007.32 24 15.16 2858 1040 1.24 / 105.10 2 7
3 13 1961.20 25 15.00 2788 1045 2.29 / 106.14 2 12
4 13 1204.68 25 15.12 1879 710 3.00 / 106.85 2 14
5 13 468.24 25 15.27 938 358 3.35 / 107.21 2 16
6 13 34.08 25 15.34 386 148 3.50 / 107.36 2 16
7 8 -0.12 165 15.28 329 829 4.33 / 108.19 2 17
Average= 4.16
(KJ/cycle)

Cycle 24 GMT 5/ 9/2023 2: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 29 15.22 491 217 0.22 / 99.61 2 4
2 7 2009.92 24 15.15 2866 1042 1.26 / 100.65 2 8
3 13 1962.88 25 15.00 2792 1047 2.31 / 101.70 2 13
4 13 1187.04 25 15.11 1861 703 3.01 / 102.40 2 15
5 13 345.52 25 15.29 794 304 3.31 / 102.70 2 16
6 13 37.40 25 15.33 399 153 3.47 / 102.85 2 16
7 13 11.28 25 15.32 364 139 3.60 / 102.99 2 18
8 8 -1.64 165 15.27 342 862 4.47 / 103.86 2 21
Average= 4.15
(KJ/cycle)

Cycle 23 GMT 26/ 8/2023 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 29 15.23 462 204 0.20 / 95.15 2 3
2 7 2009.48 25 15.14 2861 1083 1.29 / 96.23 2 9
3 13 1962.84 25 15.00 2804 1051 2.34 / 97.29 2 12
4 13 1228.20 25 15.08 1929 727 3.07 / 98.01 2 14
5 13 430.44 25 15.25 923 352 3.42 / 98.37 2 16
6 13 26.52 25 15.33 392 150 3.57 / 98.52 2 16
7 8 -2.32 165 15.27 347 874 4.44 / 99.39 2 21
Average= 4.14
(KJ/cycle)

Cycle 22 GMT 16/ 8/2023 11:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 29 15.22 457 202 0.20 / 90.84 2 3
2 7 2008.80 24 15.16 2866 1043 1.24 / 91.88 2 9
3 13 1909.20 25 15.03 2737 1028 2.27 / 92.91 2 12
4 13 1147.28 25 15.12 1817 687 2.96 / 93.59 2 16
5 13 429.36 25 15.26 923 352 3.31 / 93.95 2 16
6 13 34.56 25 15.33 394 151 3.46 / 94.10 2 16
7 8 -0.08 165 15.28 337 850 4.31 / 94.95 2 17
Average= 4.13
(KJ/cycle)

Cycle 21 GMT 6/ 8/2023 15:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 29 15.22 466 206 0.21 / 86.35 2 3
2 7 2006.20 24 15.16 2860 1041 1.25 / 87.39 2 8
3 13 1960.00 25 15.02 2782 1045 2.29 / 88.44 2 11
4 13 1189.12 25 15.10 1872 707 3.00 / 89.14 2 14
5 13 414.08 25 15.25 898 342 3.34 / 89.48 2 17
6 13 44.52 25 15.33 403 154 3.49 / 89.64 2 15
7 13 18.60 25 15.32 364 139 3.63 / 89.78 2 18
8 8 0.72 165 15.27 340 857 4.49 / 90.64 2 18
Average= 4.12
(KJ/cycle)

Cycle 20 GMT 27/ 7/2023 20:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 29 15.25 479 212 0.21 / 81.81 2 3
2 7 2004.24 25 15.17 2853 1082 1.29 / 82.89 2 7
3 13 1955.80 25 15.03 2785 1046 2.34 / 83.93 2 11
4 13 1184.16 25 15.14 1862 705 3.05 / 84.64 2 16
5 13 407.20 25 15.31 889 340 3.39 / 84.98 2 17
6 13 39.56 25 15.36 402 154 3.54 / 85.13 2 16
7 13 13.36 25 15.34 369 142 3.68 / 85.27 2 17
8 8 -0.84 165 15.28 345 870 4.55 / 86.14 2 21
Average= 4.10
(KJ/cycle)

Cycle 19 GMT 18/ 7/2023 2:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 29 15.24 490 217 0.22 / 77.51 2 3
2 7 2003.36 30 15.08 2839 1284 1.50 / 78.79 2 11
3 13 1745.48 21 15.05 2538 802 2.30 / 79.59 2 12
4 13 1177.68 21 15.12 1860 591 2.89 / 80.18 2 15
5 13 477.12 21 15.27 976 313 3.21 / 80.50 2 16
6 13 33.92 21 15.35 396 128 3.33 / 80.62 2 14
7 13 26.84 21 15.33 384 124 3.46 / 80.75 2 16
8 8 0.32 165 15.28 336 847 4.31 / 81.59 2 18
Average= 4.08
(KJ/cycle)

Cycle 18 GMT 8/ 7/2023 6:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 29 15.25 474 210 0.21 / 73.18 2 4
2 7 2004.44 30 15.08 2844 1287 1.50 / 74.47 2 10
3 13 1797.04 21 15.04 2599 821 2.32 / 75.29 2 12
4 13 1155.28 21 15.15 1815 577 2.89 / 75.87 2 15
5 13 454.12 21 15.28 927 297 3.19 / 76.16 2 16
6 13 34.92 21 15.35 383 123 3.32 / 76.29 2 16
7 13 22.80 21 15.35 379 122 3.44 / 76.41 2 15
8 8 2.24 165 15.30 348 879 4.32 / 77.29 2 19
Average= 4.07
(KJ/cycle)

Cycle 17 GMT 28/ 6/2023 12: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 29 15.24 492 217 0.22 / 68.95 2 3
2 7 2002.88 31 15.09 2845 1331 1.55 / 70.28 2 11
3 13 1732.92 21 15.07 2525 799 2.35 / 71.08 2 12
4 13 1161.64 21 15.15 1827 581 2.93 / 71.66 2 15
5 13 452.20 21 15.29 920 295 3.22 / 71.96 2 16
6 13 22.08 21 15.37 365 118 3.34 / 72.07 2 15
7 8 13.24 165 15.31 356 899 4.24 / 72.97 2 19
Average= 4.05
(KJ/cycle)

Cycle 16 GMT 18/ 6/2023 16:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 29 15.24 496 219 0.22 / 64.53 2 3
2 7 2005.64 30 15.08 2846 1288 1.51 / 65.82 2 11
3 13 1904.48 21 15.05 2726 862 2.37 / 66.68 2 12
4 13 1133.32 21 15.14 1792 570 2.94 / 67.25 2 15
5 13 596.16 21 15.25 1119 358 3.30 / 67.61 2 16
6 13 27.28 21 15.36 386 125 3.42 / 67.73 2 17
7 13 15.80 21 15.34 371 120 3.54 / 67.85 2 19
8 8 -2.20 165 15.29 348 878 4.42 / 68.73 2 18
Average= 4.04
(KJ/cycle)

Cycle 15 GMT 8/ 6/2023 21:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 29 15.25 472 209 0.21 / 60.22 2 3
2 7 2005.68 30 15.08 2844 1287 1.50 / 61.51 2 8
3 13 1745.44 21 15.08 2534 802 2.30 / 62.31 2 11
4 13 1069.24 21 15.16 1730 551 2.85 / 62.86 2 15
5 13 486.88 21 15.28 997 320 3.17 / 63.18 2 17
6 13 47.40 21 15.37 413 133 3.30 / 63.31 2 16
7 13 26.08 21 15.36 390 126 3.43 / 63.44 2 17
8 8 0.36 165 15.29 346 873 4.30 / 64.31 2 23
Average= 4.02
(KJ/cycle)

Cycle 14 GMT 30/ 5/2023 2:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 29 15.25 468 207 0.21 / 55.78 2 3
2 7 2006.64 30 15.11 2854 1294 1.50 / 57.08 2 10
3 13 1957.88 21 15.04 2787 880 2.38 / 57.96 2 12
4 13 1132.00 21 15.16 1781 567 2.95 / 58.52 2 16
5 13 587.32 21 15.27 1112 357 3.30 / 58.88 2 16
6 13 48.36 21 15.36 411 133 3.44 / 59.01 2 17
7 13 26.92 21 15.35 389 125 3.56 / 59.14 2 17
8 8 1.64 165 15.30 346 873 4.44 / 60.01 2 18
Average= 4.00
(KJ/cycle)

Cycle 13 GMT 20/ 5/2023 7:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 29 15.27 500 221 0.22 / 51.71 2 3
2 7 2004.40 30 15.11 2854 1294 1.52 / 53.00 2 11
3 13 1497.44 21 15.13 2246 714 2.23 / 53.71 2 13
4 13 896.80 21 15.20 1522 486 2.71 / 54.20 2 16
5 13 313.24 21 15.31 760 244 2.96 / 54.44 2 16
6 13 33.36 21 15.36 399 129 3.09 / 54.57 2 16
7 13 15.28 21 15.35 376 121 3.21 / 54.69 2 16
8 8 -2.72 165 15.29 350 883 4.09 / 55.58 2 23
Average= 3.97
(KJ/cycle)

Cycle 12 GMT 10/ 5/2023 11:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 29 15.27 476 211 0.21 / 47.70 2 3
2 7 2009.52 39 15.05 2845 1670 1.88 / 49.37 2 10
3 13 1258.52 18 15.17 1958 535 2.42 / 49.91 2 13
4 13 689.48 18 15.25 1257 345 2.76 / 50.25 2 16
5 13 120.88 18 15.37 499 138 2.90 / 50.39 2 14
6 13 33.92 18 15.38 395 109 3.01 / 50.50 2 14
7 13 20.84 18 15.37 379 105 3.11 / 50.61 2 15
8 8 1.84 165 15.31 348 879 3.99 / 51.48 2 18
Average= 3.96
(KJ/cycle)

Cycle 11 GMT 30/ 4/2023 15:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 29 15.27 455 201 0.20 / 43.89 2 3
2 7 2002.84 38 15.05 2824 1615 1.82 / 45.50 2 10
3 13 1257.08 18 15.17 1945 531 2.35 / 46.04 2 13
4 13 733.16 18 15.26 1286 353 2.70 / 46.39 2 15
5 13 74.44 18 15.38 404 112 2.81 / 46.50 2 12
6 13 24.48 18 15.38 366 101 2.91 / 46.60 2 11
7 8 12.00 165 15.33 352 890 3.80 / 47.49 2 16
Average= 3.96
(KJ/cycle)

Cycle 10 GMT 20/ 4/2023 18:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 29 15.26 469 208 0.21 / 39.23 2 3
2 7 2004.96 74 14.95 2831 3132 3.34 / 42.36 2 11
3 13 443.24 18 15.32 933 257 3.60 / 42.62 2 15
4 13 47.00 18 15.38 408 113 3.71 / 42.73 2 13
5 13 20.52 18 15.37 377 104 3.81 / 42.84 2 14
6 8 -1.08 165 15.32 337 852 4.67 / 43.69 2 18
Average= 3.97
(KJ/cycle)

Cycle 9 GMT 10/ 4/2023 21: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 28 15.26 487 208 0.21 / 34.44 2 2
2 7 2005.00 74 14.93 2848 3147 3.35 / 37.58 2 11
3 13 370.36 18 15.33 839 232 3.59 / 37.81 2 14
4 13 49.96 18 15.39 420 116 3.70 / 37.93 2 13
5 13 37.40 18 15.37 406 112 3.81 / 38.04 2 14
6 13 10.92 18 15.35 367 101 3.92 / 38.14 2 14
7 8 -1.04 165 15.30 348 879 4.79 / 39.02 2 20
Average= 3.90
(KJ/cycle)

Cycle 8 GMT 31/ 3/2023 23: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 29 15.26 488 216 0.22 / 29.62 2 3
2 7 2007.64 74 14.95 2828 3129 3.34 / 32.75 2 11
3 13 508.56 18 15.30 1015 280 3.62 / 33.03 2 15
4 13 45.64 18 15.39 414 115 3.74 / 33.15 2 13
5 13 25.40 18 15.38 392 109 3.85 / 33.26 2 14
6 13 10.96 18 15.37 365 101 3.95 / 33.36 2 14
7 8 -0.16 165 15.31 345 872 4.82 / 34.23 2 19
Average= 3.80
(KJ/cycle)

Cycle 7 GMT 22/ 3/2023 1:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 28 15.26 499 213 0.21 / 25.24 2 3
2 7 1729.12 75 15.02 2520 2839 3.05 / 28.08 2 10
3 13 329.20 18 15.33 790 218 3.27 / 28.30 2 13
4 13 43.72 18 15.38 415 115 3.38 / 28.41 2 14
5 13 18.44 18 15.37 383 106 3.49 / 28.52 2 14
6 8 0.36 165 15.32 351 887 4.38 / 29.41 2 19
Average= 3.68
(KJ/cycle)

Cycle 6 GMT 21/ 3/2023 0:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 28 15.27 479 205 0.20 / 20.87 2 3
2 7 1736.80 74 15.02 2538 2821 3.03 / 23.69 2 10
3 13 368.68 18 15.33 836 231 3.26 / 23.92 2 13
4 13 39.28 18 15.38 407 113 3.37 / 24.04 2 13
5 13 25.04 18 15.37 391 108 3.48 / 24.15 2 14
6 8 -0.84 165 15.31 350 884 4.36 / 25.03 2 21
Average= 3.58
(KJ/cycle)

Cycle 5 GMT 20/ 3/2023 0: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 28 15.27 470 201 0.20 / 16.56 2 3
2 7 1705.80 74 15.04 2498 2780 2.98 / 19.34 2 10
3 13 365.76 18 15.33 839 232 3.21 / 19.57 2 13
4 13 40.60 18 15.38 409 113 3.33 / 19.68 2 13
5 13 22.40 18 15.37 386 107 3.43 / 19.79 2 14
6 8 0.72 165 15.32 348 880 4.31 / 20.67 2 19
Average= 3.44
(KJ/cycle)

Cycle 4 GMT 18/ 3/2023 23:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 28 15.28 482 206 0.21 / 12.55 2 3
2 7 1509.24 74 15.09 2262 2526 2.73 / 15.07 2 11
3 13 253.04 18 15.36 679 188 2.92 / 15.26 2 13
4 13 41.24 18 15.39 404 112 3.03 / 15.37 2 14
5 13 21.96 18 15.37 383 106 3.14 / 15.48 2 14
6 8 0.56 165 15.32 347 877 4.01 / 16.36 2 19
Average= 3.27
(KJ/cycle)

Cycle 3 GMT 17/ 3/2023 23:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 26 15.26 490 194 0.19 / 8.76 2 3
2 10 1020.72 2 15.31 1715 53 0.25 / 8.81 2 6
3 7 1448.16 74 15.10 2180 2436 2.68 / 11.24 2 11
4 13 47.20 18 15.40 410 114 2.80 / 11.36 2 12
5 13 35.12 18 15.39 395 109 2.91 / 11.47 2 14
6 8 -1.88 165 15.34 345 873 3.78 / 12.34 2 19
Average= 3.09
(KJ/cycle)

Cycle 2 GMT 16/ 3/2023 23:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 31 15.27 465 220 0.22 / 4.96 2 3
2 3 861.64 -3 15.66 0 0 0.00 / 4.96 2 3
3 3 961.56 -1 15.67 0 0 0.00 / 4.96 2 3
4 7 1509.40 74 15.08 2254 2515 2.74 / 7.48 2 11
5 13 85.04 18 15.38 456 126 2.86 / 7.60 2 13
6 13 32.52 18 15.39 388 107 2.97 / 7.71 2 14
7 8 0.04 165 15.33 337 852 3.82 / 8.56 2 18
Average= 2.85
(KJ/cycle)

Cycle 1 GMT 15/ 3/2023 23:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 26 15.47 448 180 0.18 / 1.91 2 3
2 3 1035.28 1 15.38 1766 27 0.21 / 1.93 2 7
3 7 1002.60 74 15.22 1620 1825 2.03 / 3.76 2 12
4 13 32.32 18 15.41 391 108 2.14 / 3.87 2 15
5 8 -0.40 165 15.35 345 874 3.01 / 4.74 2 21
Average= 2.37
(KJ/cycle)

Cycle 0 GMT 15/ 3/2023 13: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.92 26 15.66 388 158 0.16 / 0.16 2 4
2 7 77.72 74 15.62 407 470 0.63 / 0.63 2 5
3 8 0.16 240 15.56 294 1098 1.73 / 1.73 2 14
Average= 1.73
(KJ/cycle)