SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 28 | 15.09 | 419 | 177 | 0.18 / 273.78 | 2 | 3 |
2 | 7 | 2011.28 | 38 | 14.65 | 2936 | 1634 | 1.81 / 275.42 | 2 | 3 |
3 | 13 | 1286.24 | 18 | 14.81 | 2030 | 541 | 2.35 / 275.96 | 2 | 4 |
4 | 13 | 694.08 | 18 | 14.94 | 1249 | 336 | 2.69 / 276.29 | 2 | 4 |
5 | 13 | 246.72 | 18 | 15.08 | 633 | 172 | 2.86 / 276.46 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.11 | 270 | 673 | 3.53 / 277.14 | 2 | 10 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 28 | 15.10 | 412 | 174 | 0.17 / 270.20 | 2 | 2 |
2 | 7 | 2003.96 | 39 | 14.67 | 2936 | 1680 | 1.85 / 271.88 | 2 | 5 |
3 | 13 | 1324.20 | 18 | 14.80 | 2064 | 550 | 2.40 / 272.43 | 2 | 3 |
4 | 13 | 660.60 | 18 | 14.97 | 1211 | 326 | 2.73 / 272.75 | 2 | 3 |
5 | 13 | 255.92 | 18 | 15.08 | 645 | 175 | 2.91 / 272.93 | 2 | 3 |
6 | 8 | 0.56 | 165 | 15.12 | 270 | 674 | 3.58 / 273.60 | 2 | 11 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 28 | 15.09 | 414 | 175 | 0.17 / 266.63 | 2 | 2 |
2 | 7 | 2005.48 | 38 | 14.67 | 2912 | 1623 | 1.80 / 268.25 | 2 | 4 |
3 | 13 | 1364.20 | 18 | 14.80 | 2111 | 562 | 2.36 / 268.82 | 2 | 7 |
4 | 13 | 674.84 | 18 | 14.96 | 1230 | 331 | 2.69 / 269.15 | 2 | 3 |
5 | 13 | 316.52 | 18 | 15.08 | 732 | 199 | 2.89 / 269.35 | 2 | 4 |
6 | 8 | 0.28 | 165 | 15.13 | 272 | 679 | 3.57 / 270.02 | 2 | 11 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.40 | 28 | 15.09 | 430 | 182 | 0.18 / 263.08 | 2 | 2 |
2 | 7 | 2004.04 | 38 | 14.68 | 2923 | 1631 | 1.81 / 264.71 | 2 | 5 |
3 | 13 | 1217.16 | 18 | 14.83 | 1934 | 516 | 2.33 / 265.23 | 2 | 4 |
4 | 13 | 836.76 | 18 | 14.90 | 1450 | 389 | 2.72 / 265.62 | 2 | 3 |
5 | 13 | 230.52 | 18 | 15.10 | 609 | 166 | 2.88 / 265.78 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.13 | 270 | 674 | 3.56 / 266.46 | 2 | 9 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 28 | 15.09 | 418 | 177 | 0.18 / 259.55 | 2 | 3 |
2 | 7 | 2010.88 | 38 | 14.67 | 2932 | 1634 | 1.81 / 261.19 | 2 | 3 |
3 | 13 | 1222.52 | 18 | 14.82 | 1951 | 520 | 2.33 / 261.71 | 2 | 3 |
4 | 13 | 703.68 | 18 | 14.95 | 1266 | 341 | 2.67 / 262.05 | 2 | 3 |
5 | 13 | 247.88 | 18 | 15.09 | 632 | 172 | 2.84 / 262.22 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.13 | 271 | 677 | 3.52 / 262.90 | 2 | 13 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 28 | 15.08 | 433 | 183 | 0.18 / 256.00 | 2 | 3 |
2 | 7 | 2004.04 | 38 | 14.66 | 2934 | 1634 | 1.82 / 257.64 | 2 | 3 |
3 | 13 | 1280.28 | 18 | 14.81 | 2016 | 537 | 2.35 / 258.18 | 2 | 4 |
4 | 13 | 697.04 | 18 | 14.96 | 1252 | 337 | 2.69 / 258.51 | 2 | 4 |
5 | 13 | 284.80 | 18 | 15.09 | 690 | 187 | 2.88 / 258.70 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.13 | 271 | 677 | 3.56 / 259.38 | 2 | 6 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 28 | 15.11 | 422 | 179 | 0.18 / 252.44 | 2 | 3 |
2 | 7 | 2003.92 | 38 | 14.68 | 2918 | 1628 | 1.81 / 254.07 | 2 | 4 |
3 | 13 | 1260.08 | 18 | 14.84 | 1979 | 529 | 2.33 / 254.60 | 2 | 5 |
4 | 13 | 770.36 | 18 | 14.95 | 1355 | 365 | 2.70 / 254.96 | 2 | 3 |
5 | 13 | 248.80 | 18 | 15.11 | 639 | 174 | 2.87 / 255.14 | 2 | 3 |
6 | 8 | 0.72 | 165 | 15.15 | 274 | 685 | 3.56 / 255.82 | 2 | 12 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 28 | 15.11 | 424 | 179 | 0.18 / 248.91 | 2 | 3 |
2 | 7 | 2013.48 | 38 | 14.68 | 2948 | 1645 | 1.82 / 250.56 | 2 | 3 |
3 | 13 | 1227.76 | 18 | 14.85 | 1952 | 522 | 2.35 / 251.08 | 2 | 4 |
4 | 13 | 734.28 | 18 | 14.96 | 1303 | 351 | 2.70 / 251.43 | 2 | 3 |
5 | 13 | 226.64 | 18 | 15.12 | 604 | 164 | 2.86 / 251.59 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.15 | 268 | 670 | 3.53 / 252.26 | 2 | 11 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 28 | 15.12 | 421 | 178 | 0.18 / 245.30 | 2 | 3 |
2 | 7 | 2006.92 | 38 | 14.68 | 2944 | 1642 | 1.82 / 246.94 | 2 | 4 |
3 | 13 | 1354.80 | 18 | 14.83 | 2110 | 563 | 2.38 / 247.50 | 2 | 3 |
4 | 13 | 749.12 | 18 | 14.97 | 1323 | 356 | 2.74 / 247.86 | 2 | 4 |
5 | 13 | 278.60 | 18 | 15.11 | 684 | 186 | 2.93 / 248.04 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.16 | 275 | 688 | 3.61 / 248.73 | 2 | 11 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 28 | 15.10 | 424 | 179 | 0.18 / 241.66 | 2 | 2 |
2 | 7 | 2008.96 | 39 | 14.67 | 2946 | 1685 | 1.86 / 243.34 | 2 | 3 |
3 | 13 | 1382.72 | 18 | 14.80 | 2147 | 572 | 2.44 / 243.92 | 2 | 5 |
4 | 13 | 721.12 | 18 | 14.98 | 1287 | 347 | 2.78 / 244.26 | 2 | 3 |
5 | 13 | 254.76 | 18 | 15.13 | 650 | 177 | 2.96 / 244.44 | 2 | 3 |
6 | 8 | -0.52 | 165 | 15.16 | 271 | 678 | 3.64 / 245.12 | 2 | 13 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 28 | 15.12 | 417 | 177 | 0.18 / 238.11 | 2 | 2 |
2 | 7 | 2008.48 | 38 | 14.67 | 2932 | 1634 | 1.81 / 239.74 | 2 | 4 |
3 | 13 | 1278.64 | 18 | 14.84 | 1990 | 532 | 2.34 / 240.27 | 2 | 4 |
4 | 13 | 729.56 | 18 | 14.97 | 1302 | 351 | 2.69 / 240.62 | 2 | 3 |
5 | 13 | 265.04 | 18 | 15.12 | 661 | 180 | 2.87 / 240.80 | 2 | 4 |
6 | 8 | 0.32 | 165 | 15.15 | 271 | 677 | 3.55 / 241.48 | 2 | 12 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.04 | 28 | 15.11 | 430 | 182 | 0.18 / 234.57 | 2 | 2 |
2 | 7 | 2011.88 | 38 | 14.68 | 2938 | 1639 | 1.82 / 236.21 | 2 | 4 |
3 | 13 | 1221.28 | 18 | 14.86 | 1929 | 516 | 2.34 / 236.73 | 2 | 4 |
4 | 13 | 694.08 | 18 | 14.99 | 1254 | 338 | 2.68 / 237.07 | 2 | 4 |
5 | 13 | 271.44 | 18 | 15.11 | 667 | 181 | 2.86 / 237.25 | 2 | 4 |
6 | 8 | 0.52 | 165 | 15.15 | 272 | 680 | 3.54 / 237.93 | 2 | 7 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.44 | 28 | 15.12 | 430 | 182 | 0.18 / 231.05 | 2 | 3 |
2 | 7 | 2003.48 | 38 | 14.69 | 2918 | 1629 | 1.81 / 232.68 | 2 | 4 |
3 | 13 | 1286.12 | 18 | 14.83 | 2024 | 540 | 2.35 / 233.22 | 2 | 4 |
4 | 13 | 662.32 | 18 | 15.00 | 1209 | 326 | 2.68 / 233.55 | 2 | 3 |
5 | 13 | 235.28 | 18 | 15.12 | 617 | 168 | 2.85 / 233.72 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.16 | 270 | 675 | 3.52 / 234.39 | 2 | 10 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 28 | 15.13 | 411 | 174 | 0.17 / 227.44 | 2 | 2 |
2 | 7 | 2011.76 | 39 | 14.69 | 2931 | 1679 | 1.85 / 229.12 | 2 | 3 |
3 | 13 | 1344.00 | 18 | 14.83 | 2101 | 561 | 2.41 / 229.68 | 2 | 4 |
4 | 13 | 697.60 | 18 | 14.99 | 1262 | 341 | 2.75 / 230.03 | 2 | 3 |
5 | 13 | 246.76 | 18 | 15.13 | 635 | 173 | 2.93 / 230.20 | 2 | 4 |
6 | 8 | -0.40 | 165 | 15.17 | 269 | 673 | 3.60 / 230.87 | 2 | 11 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 28 | 15.13 | 414 | 175 | 0.18 / 223.89 | 2 | 2 |
2 | 7 | 2002.36 | 38 | 14.69 | 2922 | 1631 | 1.81 / 225.52 | 2 | 4 |
3 | 13 | 1284.68 | 18 | 14.84 | 2011 | 537 | 2.34 / 226.06 | 2 | 4 |
4 | 13 | 740.96 | 18 | 14.97 | 1321 | 356 | 2.70 / 226.42 | 2 | 3 |
5 | 13 | 268.20 | 18 | 15.12 | 664 | 181 | 2.88 / 226.60 | 2 | 4 |
6 | 8 | 0.60 | 165 | 15.16 | 269 | 673 | 3.55 / 227.27 | 2 | 13 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 28 | 15.12 | 424 | 180 | 0.18 / 220.37 | 2 | 3 |
2 | 7 | 2004.64 | 38 | 14.69 | 2913 | 1626 | 1.81 / 222.00 | 2 | 4 |
3 | 13 | 1293.04 | 18 | 14.86 | 2032 | 544 | 2.35 / 222.54 | 2 | 4 |
4 | 13 | 703.08 | 18 | 15.00 | 1263 | 341 | 2.69 / 222.88 | 2 | 3 |
5 | 13 | 238.68 | 18 | 15.14 | 620 | 169 | 2.86 / 223.05 | 2 | 3 |
6 | 8 | 0.72 | 165 | 15.18 | 266 | 666 | 3.53 / 223.72 | 2 | 7 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 28 | 15.13 | 416 | 176 | 0.18 / 216.80 | 2 | 2 |
2 | 7 | 2004.12 | 38 | 14.70 | 2909 | 1625 | 1.80 / 218.43 | 2 | 3 |
3 | 13 | 1283.32 | 18 | 14.85 | 2023 | 541 | 2.34 / 218.97 | 2 | 3 |
4 | 13 | 737.80 | 18 | 14.99 | 1317 | 355 | 2.70 / 219.33 | 2 | 4 |
5 | 13 | 260.24 | 18 | 15.13 | 655 | 178 | 2.88 / 219.50 | 2 | 4 |
6 | 8 | 0.60 | 165 | 15.17 | 275 | 688 | 3.56 / 220.19 | 2 | 10 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 28 | 15.13 | 400 | 169 | 0.17 / 213.18 | 2 | 2 |
2 | 7 | 2004.32 | 38 | 14.70 | 2912 | 1627 | 1.80 / 214.80 | 2 | 3 |
3 | 13 | 1369.48 | 18 | 14.84 | 2133 | 570 | 2.37 / 215.37 | 2 | 4 |
4 | 13 | 858.28 | 18 | 14.94 | 1463 | 393 | 2.76 / 215.77 | 2 | 4 |
5 | 13 | 273.00 | 18 | 15.13 | 674 | 184 | 2.94 / 215.95 | 2 | 4 |
6 | 8 | -0.24 | 165 | 15.17 | 271 | 678 | 3.62 / 216.63 | 2 | 15 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.64 | 28 | 15.14 | 419 | 178 | 0.18 / 209.70 | 2 | 3 |
2 | 7 | 2006.68 | 38 | 14.69 | 2929 | 1635 | 1.81 / 211.33 | 2 | 4 |
3 | 13 | 1287.08 | 18 | 14.86 | 2013 | 538 | 2.35 / 211.87 | 2 | 4 |
4 | 13 | 620.80 | 18 | 15.03 | 1159 | 314 | 2.66 / 212.18 | 2 | 4 |
5 | 13 | 188.56 | 18 | 15.16 | 546 | 149 | 2.81 / 212.33 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.17 | 269 | 673 | 3.49 / 213.01 | 2 | 10 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.64 | 28 | 15.12 | 427 | 181 | 0.18 / 206.22 | 2 | 2 |
2 | 7 | 2004.44 | 38 | 14.70 | 2926 | 1634 | 1.82 / 207.86 | 2 | 6 |
3 | 13 | 1199.16 | 18 | 14.90 | 1901 | 510 | 2.33 / 208.37 | 2 | 5 |
4 | 13 | 667.80 | 18 | 15.03 | 1219 | 330 | 2.65 / 208.70 | 2 | 4 |
5 | 13 | 189.68 | 18 | 15.18 | 548 | 150 | 2.80 / 208.85 | 2 | 4 |
6 | 8 | 0.48 | 165 | 15.19 | 268 | 672 | 3.48 / 209.52 | 2 | 13 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 28 | 15.16 | 416 | 177 | 0.18 / 202.67 | 2 | 3 |
2 | 7 | 2008.88 | 38 | 14.69 | 2933 | 1637 | 1.81 / 204.31 | 2 | 4 |
3 | 13 | 1246.20 | 18 | 14.87 | 1984 | 531 | 2.34 / 204.84 | 2 | 4 |
4 | 13 | 753.36 | 18 | 14.99 | 1334 | 360 | 2.70 / 205.20 | 2 | 4 |
5 | 13 | 237.92 | 18 | 15.16 | 618 | 169 | 2.87 / 205.37 | 2 | 4 |
6 | 8 | -0.24 | 165 | 15.18 | 269 | 674 | 3.55 / 206.04 | 2 | 14 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 28 | 15.15 | 422 | 179 | 0.18 / 199.11 | 2 | 2 |
2 | 7 | 2010.68 | 38 | 14.70 | 2946 | 1646 | 1.82 / 200.76 | 2 | 4 |
3 | 13 | 1309.76 | 18 | 14.87 | 2046 | 548 | 2.37 / 201.31 | 2 | 6 |
4 | 13 | 753.20 | 18 | 15.00 | 1332 | 360 | 2.73 / 201.67 | 2 | 3 |
5 | 13 | 209.12 | 18 | 15.18 | 576 | 157 | 2.89 / 201.82 | 2 | 3 |
6 | 8 | -0.20 | 165 | 15.19 | 268 | 672 | 3.56 / 202.50 | 2 | 7 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 28 | 15.15 | 406 | 172 | 0.17 / 195.54 | 2 | 2 |
2 | 7 | 2006.52 | 39 | 14.70 | 2928 | 1679 | 1.85 / 197.22 | 2 | 3 |
3 | 13 | 1247.32 | 18 | 14.88 | 1966 | 527 | 2.38 / 197.75 | 2 | 3 |
4 | 13 | 704.60 | 18 | 15.02 | 1267 | 343 | 2.72 / 198.09 | 2 | 4 |
5 | 13 | 247.52 | 18 | 15.15 | 632 | 172 | 2.89 / 198.26 | 2 | 3 |
6 | 8 | 0.52 | 165 | 15.18 | 269 | 674 | 3.57 / 198.94 | 2 | 12 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.96 | 28 | 15.15 | 413 | 175 | 0.18 / 192.00 | 2 | 3 |
2 | 7 | 2003.80 | 38 | 14.69 | 2933 | 1637 | 1.81 / 193.64 | 2 | 3 |
3 | 13 | 1266.96 | 18 | 14.87 | 2000 | 535 | 2.35 / 194.17 | 2 | 4 |
4 | 13 | 692.32 | 18 | 15.02 | 1252 | 338 | 2.69 / 194.51 | 2 | 3 |
5 | 13 | 279.80 | 18 | 15.15 | 680 | 185 | 2.87 / 194.70 | 2 | 4 |
6 | 8 | 0.36 | 165 | 15.18 | 269 | 674 | 3.55 / 195.37 | 2 | 15 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 28 | 15.16 | 418 | 177 | 0.18 / 188.49 | 2 | 3 |
2 | 7 | 2003.04 | 38 | 14.71 | 2925 | 1635 | 1.81 / 190.12 | 2 | 3 |
3 | 13 | 1223.96 | 18 | 14.90 | 1950 | 523 | 2.34 / 190.64 | 2 | 4 |
4 | 13 | 678.88 | 18 | 15.03 | 1226 | 332 | 2.67 / 190.98 | 2 | 3 |
5 | 13 | 262.28 | 18 | 15.16 | 657 | 179 | 2.85 / 191.15 | 2 | 4 |
6 | 8 | -0.28 | 165 | 15.20 | 267 | 670 | 3.52 / 191.82 | 2 | 11 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.24 | 28 | 15.16 | 413 | 175 | 0.18 / 184.91 | 2 | 2 |
2 | 7 | 2006.08 | 38 | 14.72 | 2931 | 1639 | 1.81 / 186.55 | 2 | 3 |
3 | 13 | 1259.44 | 18 | 14.90 | 1985 | 532 | 2.35 / 187.08 | 2 | 6 |
4 | 13 | 774.40 | 18 | 15.01 | 1371 | 370 | 2.72 / 187.45 | 2 | 4 |
5 | 13 | 258.92 | 18 | 15.17 | 653 | 178 | 2.90 / 187.63 | 2 | 4 |
6 | 8 | -0.12 | 165 | 15.20 | 269 | 675 | 3.57 / 188.31 | 2 | 13 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 28 | 15.17 | 422 | 179 | 0.18 / 181.31 | 2 | 3 |
2 | 7 | 2005.52 | 38 | 14.72 | 2928 | 1638 | 1.82 / 182.95 | 2 | 4 |
3 | 13 | 1319.00 | 18 | 14.88 | 2076 | 556 | 2.37 / 183.51 | 2 | 5 |
4 | 13 | 758.44 | 18 | 15.03 | 1345 | 364 | 2.74 / 183.87 | 2 | 4 |
5 | 13 | 281.72 | 18 | 15.18 | 688 | 188 | 2.92 / 184.06 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.21 | 270 | 678 | 3.60 / 184.74 | 2 | 11 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 28 | 15.17 | 413 | 175 | 0.18 / 177.70 | 2 | 2 |
2 | 7 | 2003.72 | 39 | 14.71 | 2928 | 1680 | 1.86 / 179.38 | 2 | 4 |
3 | 13 | 1321.16 | 18 | 14.89 | 2078 | 557 | 2.41 / 179.94 | 2 | 3 |
4 | 13 | 683.52 | 18 | 15.04 | 1247 | 338 | 2.75 / 180.27 | 2 | 4 |
5 | 13 | 265.60 | 18 | 15.18 | 666 | 182 | 2.93 / 180.46 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.20 | 271 | 680 | 3.61 / 181.13 | 2 | 11 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 28 | 15.16 | 429 | 182 | 0.18 / 174.17 | 2 | 2 |
2 | 7 | 2010.88 | 38 | 14.72 | 2926 | 1637 | 1.82 / 175.81 | 2 | 4 |
3 | 13 | 1199.68 | 18 | 14.94 | 1929 | 519 | 2.34 / 176.33 | 2 | 4 |
4 | 13 | 663.24 | 18 | 15.07 | 1214 | 329 | 2.67 / 176.66 | 2 | 4 |
5 | 13 | 256.44 | 18 | 15.19 | 653 | 179 | 2.85 / 176.84 | 2 | 4 |
6 | 8 | -0.44 | 165 | 15.22 | 274 | 688 | 3.53 / 177.52 | 2 | 11 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 28 | 15.19 | 419 | 178 | 0.18 / 170.63 | 2 | 2 |
2 | 7 | 2009.88 | 38 | 14.71 | 2933 | 1639 | 1.82 / 172.26 | 2 | 3 |
3 | 13 | 1208.32 | 18 | 14.91 | 1930 | 518 | 2.34 / 172.78 | 2 | 4 |
4 | 13 | 729.84 | 18 | 15.03 | 1305 | 353 | 2.69 / 173.14 | 2 | 5 |
5 | 13 | 258.04 | 18 | 15.17 | 647 | 177 | 2.87 / 173.31 | 2 | 4 |
6 | 8 | 0.44 | 165 | 15.21 | 270 | 678 | 3.54 / 173.99 | 2 | 11 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.00 | 28 | 15.17 | 432 | 183 | 0.18 / 167.10 | 2 | 2 |
2 | 7 | 2010.08 | 39 | 14.73 | 2921 | 1678 | 1.86 / 168.77 | 2 | 3 |
3 | 13 | 1247.88 | 18 | 14.91 | 1962 | 527 | 2.39 / 169.30 | 2 | 5 |
4 | 13 | 634.88 | 18 | 15.08 | 1177 | 319 | 2.71 / 169.62 | 2 | 3 |
5 | 13 | 197.48 | 18 | 15.21 | 561 | 154 | 2.86 / 169.77 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.21 | 268 | 673 | 3.53 / 170.45 | 2 | 6 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 28 | 15.18 | 421 | 179 | 0.18 / 163.54 | 2 | 3 |
2 | 7 | 2004.36 | 38 | 14.72 | 2928 | 1638 | 1.82 / 165.17 | 2 | 4 |
3 | 13 | 1280.92 | 18 | 14.90 | 2023 | 543 | 2.36 / 165.72 | 2 | 4 |
4 | 13 | 720.28 | 18 | 15.05 | 1292 | 350 | 2.71 / 166.07 | 2 | 3 |
5 | 13 | 219.24 | 18 | 15.21 | 598 | 164 | 2.87 / 166.23 | 2 | 4 |
6 | 8 | -0.68 | 165 | 15.22 | 272 | 683 | 3.56 / 166.91 | 2 | 13 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 28 | 15.19 | 414 | 176 | 0.18 / 159.96 | 2 | 2 |
2 | 7 | 2004.68 | 38 | 14.72 | 2928 | 1638 | 1.81 / 161.60 | 2 | 4 |
3 | 13 | 1334.76 | 18 | 14.89 | 2095 | 562 | 2.38 / 162.16 | 2 | 5 |
4 | 13 | 730.16 | 18 | 15.04 | 1311 | 355 | 2.73 / 162.52 | 2 | 4 |
5 | 13 | 226.76 | 18 | 15.21 | 604 | 165 | 2.90 / 162.68 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.22 | 269 | 676 | 3.57 / 163.36 | 2 | 14 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 28 | 15.21 | 415 | 177 | 0.18 / 156.34 | 2 | 3 |
2 | 7 | 2003.88 | 39 | 14.72 | 2928 | 1681 | 1.86 / 158.02 | 2 | 5 |
3 | 13 | 1314.36 | 18 | 14.89 | 2066 | 554 | 2.41 / 158.57 | 2 | 5 |
4 | 13 | 720.64 | 18 | 15.05 | 1294 | 351 | 2.76 / 158.92 | 2 | 3 |
5 | 13 | 257.80 | 18 | 15.19 | 652 | 178 | 2.94 / 159.10 | 2 | 4 |
6 | 8 | -0.08 | 165 | 15.22 | 272 | 683 | 3.62 / 159.79 | 2 | 4 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 28 | 15.19 | 431 | 183 | 0.18 / 152.75 | 2 | 3 |
2 | 7 | 2009.24 | 39 | 14.74 | 2933 | 1686 | 1.87 / 154.44 | 2 | 3 |
3 | 13 | 1328.96 | 18 | 14.90 | 2083 | 559 | 2.43 / 155.00 | 2 | 4 |
4 | 13 | 693.12 | 18 | 15.06 | 1253 | 340 | 2.77 / 155.34 | 2 | 3 |
5 | 13 | 190.08 | 18 | 15.22 | 547 | 150 | 2.92 / 155.49 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.23 | 268 | 673 | 3.59 / 156.16 | 2 | 16 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 28 | 15.20 | 433 | 184 | 0.18 / 149.15 | 2 | 3 |
2 | 7 | 2002.84 | 38 | 14.74 | 2927 | 1639 | 1.82 / 150.79 | 2 | 3 |
3 | 13 | 1287.40 | 18 | 14.92 | 2032 | 546 | 2.37 / 151.34 | 2 | 3 |
4 | 13 | 752.48 | 18 | 15.05 | 1332 | 361 | 2.73 / 151.70 | 2 | 4 |
5 | 13 | 281.24 | 18 | 15.20 | 685 | 187 | 2.92 / 151.89 | 2 | 4 |
6 | 8 | -0.48 | 165 | 15.24 | 273 | 686 | 3.60 / 152.57 | 2 | 11 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 28 | 15.20 | 423 | 180 | 0.18 / 145.56 | 2 | 2 |
2 | 7 | 2009.80 | 39 | 14.73 | 2939 | 1688 | 1.87 / 147.25 | 2 | 4 |
3 | 13 | 1239.32 | 18 | 14.92 | 1974 | 530 | 2.40 / 147.78 | 2 | 3 |
4 | 13 | 706.92 | 18 | 15.07 | 1277 | 346 | 2.74 / 148.12 | 2 | 4 |
5 | 13 | 204.24 | 18 | 15.22 | 572 | 157 | 2.90 / 148.28 | 2 | 3 |
6 | 8 | -0.20 | 165 | 15.24 | 273 | 686 | 3.59 / 148.97 | 2 | 13 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 28 | 15.20 | 416 | 177 | 0.18 / 142.01 | 2 | 3 |
2 | 7 | 2005.52 | 38 | 14.73 | 2925 | 1637 | 1.81 / 143.64 | 2 | 5 |
3 | 13 | 1284.08 | 18 | 14.91 | 2031 | 545 | 2.36 / 144.19 | 2 | 4 |
4 | 13 | 693.00 | 18 | 15.07 | 1254 | 340 | 2.70 / 144.53 | 2 | 4 |
5 | 13 | 238.44 | 18 | 15.21 | 622 | 170 | 2.87 / 144.70 | 2 | 4 |
6 | 8 | -0.12 | 165 | 15.23 | 271 | 681 | 3.55 / 145.38 | 2 | 13 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.88 | 27 | 15.20 | 427 | 175 | 0.18 / 138.45 | 2 | 2 |
2 | 7 | 2005.96 | 39 | 14.74 | 2932 | 1685 | 1.86 / 140.13 | 2 | 5 |
3 | 13 | 1203.52 | 18 | 14.95 | 1925 | 518 | 2.38 / 140.65 | 2 | 5 |
4 | 13 | 671.24 | 18 | 15.09 | 1223 | 332 | 2.71 / 140.98 | 2 | 4 |
5 | 13 | 223.92 | 18 | 15.22 | 603 | 165 | 2.88 / 141.15 | 2 | 4 |
6 | 8 | 0.32 | 165 | 15.24 | 271 | 681 | 3.56 / 141.83 | 2 | 13 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 27 | 15.22 | 425 | 175 | 0.17 / 134.87 | 2 | 3 |
2 | 7 | 2007.68 | 38 | 14.74 | 2935 | 1644 | 1.82 / 136.52 | 2 | 3 |
3 | 13 | 1229.68 | 18 | 14.94 | 1960 | 527 | 2.35 / 137.04 | 2 | 6 |
4 | 13 | 779.88 | 18 | 15.05 | 1376 | 373 | 2.72 / 137.42 | 2 | 4 |
5 | 13 | 251.32 | 18 | 15.22 | 640 | 175 | 2.89 / 137.59 | 2 | 4 |
6 | 8 | 0.48 | 165 | 15.24 | 270 | 679 | 3.57 / 138.27 | 2 | 6 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 27 | 15.19 | 423 | 173 | 0.17 / 131.27 | 2 | 2 |
2 | 7 | 2006.44 | 38 | 14.74 | 2925 | 1638 | 1.81 / 132.91 | 2 | 4 |
3 | 13 | 1311.52 | 18 | 14.92 | 2065 | 555 | 2.37 / 133.47 | 2 | 5 |
4 | 13 | 744.04 | 18 | 15.06 | 1329 | 360 | 2.73 / 133.83 | 2 | 4 |
5 | 13 | 264.76 | 18 | 15.22 | 666 | 182 | 2.91 / 134.01 | 2 | 4 |
6 | 8 | -0.36 | 165 | 15.25 | 274 | 689 | 3.60 / 134.70 | 2 | 9 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 27 | 15.21 | 425 | 175 | 0.17 / 127.71 | 2 | 3 |
2 | 7 | 2007.52 | 38 | 14.74 | 2932 | 1642 | 1.82 / 129.35 | 2 | 4 |
3 | 13 | 1218.60 | 18 | 14.95 | 1925 | 518 | 2.33 / 129.87 | 2 | 4 |
4 | 13 | 720.08 | 18 | 15.08 | 1293 | 351 | 2.69 / 130.22 | 2 | 4 |
5 | 13 | 251.40 | 18 | 15.22 | 650 | 178 | 2.86 / 130.40 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.23 | 279 | 701 | 3.56 / 131.10 | 2 | 15 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 27 | 15.22 | 430 | 177 | 0.18 / 124.13 | 2 | 2 |
2 | 7 | 2002.76 | 38 | 14.75 | 2925 | 1639 | 1.82 / 125.77 | 2 | 4 |
3 | 13 | 1273.56 | 18 | 14.93 | 2018 | 542 | 2.36 / 126.31 | 2 | 5 |
4 | 13 | 724.72 | 18 | 15.08 | 1296 | 352 | 2.71 / 126.66 | 2 | 3 |
5 | 13 | 264.28 | 18 | 15.21 | 667 | 183 | 2.89 / 126.84 | 2 | 4 |
6 | 8 | -0.24 | 165 | 15.25 | 275 | 692 | 3.58 / 127.53 | 2 | 13 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 27 | 15.21 | 426 | 175 | 0.17 / 120.51 | 2 | 2 |
2 | 7 | 2012.44 | 39 | 14.76 | 2947 | 1696 | 1.87 / 122.21 | 2 | 3 |
3 | 13 | 1292.76 | 18 | 14.94 | 2039 | 548 | 2.42 / 122.76 | 2 | 4 |
4 | 13 | 652.08 | 18 | 15.11 | 1200 | 326 | 2.75 / 123.08 | 2 | 4 |
5 | 13 | 248.00 | 18 | 15.23 | 644 | 177 | 2.92 / 123.26 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.25 | 274 | 689 | 3.61 / 123.95 | 2 | 11 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 27 | 15.21 | 430 | 177 | 0.18 / 116.96 | 2 | 3 |
2 | 7 | 2009.96 | 38 | 14.75 | 2934 | 1645 | 1.82 / 118.61 | 2 | 4 |
3 | 13 | 1238.20 | 18 | 14.95 | 1977 | 532 | 2.35 / 119.14 | 2 | 5 |
4 | 13 | 696.84 | 18 | 15.09 | 1260 | 342 | 2.70 / 119.48 | 2 | 3 |
5 | 13 | 235.84 | 18 | 15.23 | 620 | 170 | 2.87 / 119.65 | 2 | 3 |
6 | 8 | -0.24 | 165 | 15.25 | 272 | 684 | 3.55 / 120.34 | 2 | 6 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 27 | 15.23 | 418 | 172 | 0.17 / 113.38 | 2 | 3 |
2 | 7 | 2005.24 | 38 | 14.76 | 2934 | 1646 | 1.82 / 115.02 | 2 | 4 |
3 | 13 | 1265.64 | 18 | 14.95 | 2002 | 539 | 2.36 / 115.56 | 2 | 4 |
4 | 13 | 754.40 | 18 | 15.08 | 1345 | 365 | 2.72 / 115.93 | 2 | 5 |
5 | 13 | 235.88 | 18 | 15.24 | 625 | 171 | 2.89 / 116.10 | 2 | 4 |
6 | 8 | 0.12 | 165 | 15.26 | 274 | 690 | 3.58 / 116.79 | 2 | 14 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 27 | 15.23 | 421 | 173 | 0.17 / 109.74 | 2 | 3 |
2 | 7 | 2002.32 | 38 | 14.76 | 2929 | 1643 | 1.82 / 111.38 | 2 | 3 |
3 | 13 | 1359.60 | 18 | 14.92 | 2115 | 568 | 2.38 / 111.95 | 2 | 5 |
4 | 13 | 836.56 | 18 | 15.06 | 1453 | 394 | 2.78 / 112.34 | 2 | 4 |
5 | 13 | 252.48 | 18 | 15.23 | 647 | 177 | 2.96 / 112.52 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.26 | 272 | 685 | 3.64 / 113.21 | 2 | 15 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 27 | 15.23 | 421 | 173 | 0.17 / 106.15 | 2 | 2 |
2 | 7 | 2003.88 | 38 | 14.76 | 2933 | 1645 | 1.82 / 107.79 | 2 | 4 |
3 | 13 | 1277.96 | 18 | 14.95 | 2021 | 544 | 2.36 / 108.34 | 2 | 4 |
4 | 13 | 737.52 | 18 | 15.08 | 1322 | 359 | 2.72 / 108.70 | 2 | 3 |
5 | 13 | 262.84 | 18 | 15.23 | 660 | 181 | 2.90 / 108.88 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.25 | 273 | 687 | 3.59 / 109.57 | 2 | 10 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 27 | 15.23 | 422 | 174 | 0.17 / 102.57 | 2 | 2 |
2 | 7 | 2010.52 | 38 | 14.76 | 2948 | 1653 | 1.83 / 104.22 | 2 | 3 |
3 | 13 | 1202.88 | 18 | 14.98 | 1928 | 520 | 2.35 / 104.74 | 2 | 3 |
4 | 13 | 748.32 | 18 | 15.09 | 1334 | 362 | 2.71 / 105.10 | 2 | 5 |
5 | 13 | 270.08 | 18 | 15.23 | 675 | 185 | 2.89 / 105.29 | 2 | 4 |
6 | 8 | -0.16 | 165 | 15.27 | 274 | 690 | 3.58 / 105.98 | 2 | 11 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 27 | 15.23 | 424 | 174 | 0.17 / 99.02 | 2 | 3 |
2 | 7 | 2003.76 | 38 | 14.78 | 2934 | 1648 | 1.82 / 100.67 | 2 | 4 |
3 | 13 | 1273.52 | 18 | 14.96 | 2023 | 545 | 2.37 / 101.22 | 2 | 4 |
4 | 13 | 676.84 | 18 | 15.12 | 1233 | 336 | 2.70 / 101.55 | 2 | 4 |
5 | 13 | 201.12 | 18 | 15.26 | 569 | 156 | 2.86 / 101.71 | 2 | 3 |
6 | 8 | 0.68 | 165 | 15.28 | 271 | 683 | 3.54 / 102.39 | 2 | 12 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 27 | 15.25 | 421 | 173 | 0.17 / 95.45 | 2 | 2 |
2 | 7 | 2004.12 | 38 | 14.78 | 2937 | 1650 | 1.82 / 97.10 | 2 | 4 |
3 | 13 | 1209.76 | 18 | 14.99 | 1944 | 525 | 2.35 / 97.62 | 2 | 6 |
4 | 13 | 751.36 | 18 | 15.10 | 1336 | 363 | 2.71 / 97.98 | 2 | 4 |
5 | 13 | 243.48 | 18 | 15.25 | 631 | 173 | 2.88 / 98.16 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.28 | 275 | 693 | 3.58 / 98.85 | 2 | 13 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.20 | 27 | 15.23 | 426 | 175 | 0.18 / 91.86 | 2 | 2 |
2 | 7 | 2003.00 | 38 | 14.78 | 2934 | 1648 | 1.82 / 93.51 | 2 | 3 |
3 | 13 | 1328.96 | 18 | 14.95 | 2083 | 561 | 2.38 / 94.07 | 2 | 6 |
4 | 13 | 688.80 | 18 | 15.13 | 1255 | 342 | 2.73 / 94.41 | 2 | 4 |
5 | 13 | 240.64 | 18 | 15.25 | 629 | 173 | 2.90 / 94.58 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.28 | 273 | 688 | 3.59 / 95.27 | 2 | 11 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 27 | 15.23 | 426 | 175 | 0.18 / 88.31 | 2 | 2 |
2 | 7 | 2005.00 | 38 | 14.77 | 2932 | 1646 | 1.82 / 89.96 | 2 | 4 |
3 | 13 | 1213.36 | 18 | 14.99 | 1938 | 523 | 2.34 / 90.48 | 2 | 4 |
4 | 13 | 677.52 | 18 | 15.11 | 1239 | 337 | 2.68 / 90.82 | 2 | 4 |
5 | 13 | 266.48 | 18 | 15.24 | 666 | 183 | 2.86 / 91.00 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.28 | 273 | 688 | 3.55 / 91.69 | 2 | 7 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 27 | 15.24 | 419 | 172 | 0.17 / 84.75 | 2 | 3 |
2 | 7 | 2003.00 | 38 | 14.78 | 2920 | 1640 | 1.81 / 86.39 | 2 | 3 |
3 | 13 | 1236.92 | 18 | 14.99 | 1959 | 529 | 2.34 / 86.92 | 2 | 4 |
4 | 13 | 707.68 | 18 | 15.11 | 1281 | 348 | 2.69 / 87.27 | 2 | 4 |
5 | 13 | 251.84 | 18 | 15.24 | 646 | 177 | 2.87 / 87.44 | 2 | 4 |
6 | 8 | 0.28 | 165 | 15.28 | 274 | 691 | 3.56 / 88.13 | 2 | 11 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.96 | 27 | 15.25 | 433 | 178 | 0.18 / 81.15 | 2 | 2 |
2 | 7 | 2003.00 | 38 | 14.79 | 2943 | 1654 | 1.83 / 82.80 | 2 | 4 |
3 | 13 | 1284.56 | 18 | 14.98 | 2034 | 548 | 2.38 / 83.35 | 2 | 5 |
4 | 13 | 776.84 | 18 | 15.09 | 1372 | 373 | 2.75 / 83.72 | 2 | 3 |
5 | 13 | 215.92 | 18 | 15.26 | 593 | 163 | 2.92 / 83.89 | 2 | 4 |
6 | 8 | 0.44 | 165 | 15.29 | 274 | 691 | 3.61 / 84.58 | 2 | 15 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 27 | 15.25 | 415 | 171 | 0.17 / 77.60 | 2 | 2 |
2 | 7 | 2005.64 | 38 | 14.79 | 2937 | 1651 | 1.82 / 79.25 | 2 | 3 |
3 | 13 | 1239.56 | 18 | 14.99 | 1983 | 535 | 2.36 / 79.79 | 2 | 5 |
4 | 13 | 686.52 | 18 | 15.12 | 1254 | 341 | 2.70 / 80.13 | 2 | 4 |
5 | 13 | 195.52 | 18 | 15.28 | 556 | 153 | 2.85 / 80.28 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.30 | 273 | 689 | 3.54 / 80.97 | 2 | 7 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 27 | 15.26 | 417 | 172 | 0.17 / 74.04 | 2 | 2 |
2 | 7 | 2010.48 | 38 | 14.79 | 2935 | 1650 | 1.82 / 75.69 | 2 | 4 |
3 | 13 | 1234.84 | 18 | 14.99 | 1970 | 532 | 2.35 / 76.22 | 2 | 3 |
4 | 13 | 692.92 | 18 | 15.14 | 1261 | 344 | 2.70 / 76.57 | 2 | 4 |
5 | 13 | 236.08 | 18 | 15.26 | 618 | 170 | 2.87 / 76.74 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.29 | 275 | 694 | 3.56 / 77.43 | 2 | 7 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 27 | 15.26 | 417 | 172 | 0.17 / 70.49 | 2 | 2 |
2 | 7 | 2004.84 | 38 | 14.79 | 2930 | 1647 | 1.82 / 72.14 | 2 | 3 |
3 | 13 | 1234.48 | 18 | 14.99 | 1952 | 527 | 2.35 / 72.67 | 2 | 4 |
4 | 13 | 668.56 | 18 | 15.13 | 1227 | 334 | 2.68 / 73.00 | 2 | 3 |
5 | 13 | 256.76 | 18 | 15.24 | 652 | 179 | 2.86 / 73.18 | 2 | 4 |
6 | 8 | 0.40 | 165 | 15.28 | 273 | 688 | 3.55 / 73.87 | 2 | 14 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 27 | 15.25 | 399 | 164 | 0.16 / 66.90 | 2 | 2 |
2 | 7 | 2004.36 | 38 | 14.79 | 2935 | 1650 | 1.81 / 68.55 | 2 | 4 |
3 | 13 | 1323.76 | 18 | 14.98 | 2088 | 563 | 2.38 / 69.12 | 2 | 6 |
4 | 13 | 732.88 | 18 | 15.12 | 1317 | 358 | 2.74 / 69.48 | 2 | 4 |
5 | 13 | 222.40 | 18 | 15.28 | 598 | 164 | 2.90 / 69.64 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.28 | 271 | 683 | 3.58 / 70.32 | 2 | 15 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.60 | 27 | 15.26 | 429 | 177 | 0.18 / 63.37 | 2 | 3 |
2 | 7 | 2003.80 | 38 | 14.79 | 2925 | 1644 | 1.82 / 65.01 | 2 | 4 |
3 | 13 | 1203.24 | 18 | 15.00 | 1932 | 522 | 2.34 / 65.53 | 2 | 5 |
4 | 13 | 711.20 | 18 | 15.13 | 1284 | 350 | 2.69 / 65.88 | 2 | 4 |
5 | 13 | 248.04 | 18 | 15.27 | 639 | 176 | 2.87 / 66.06 | 2 | 4 |
6 | 8 | 0.28 | 165 | 15.29 | 271 | 684 | 3.55 / 66.74 | 2 | 17 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 27 | 15.25 | 420 | 173 | 0.17 / 59.81 | 2 | 3 |
2 | 7 | 2003.20 | 38 | 14.80 | 2925 | 1645 | 1.82 / 61.45 | 2 | 3 |
3 | 13 | 1280.96 | 18 | 14.99 | 2024 | 546 | 2.36 / 62.00 | 2 | 5 |
4 | 13 | 759.76 | 18 | 15.12 | 1345 | 366 | 2.73 / 62.36 | 2 | 5 |
5 | 13 | 151.16 | 18 | 15.29 | 493 | 136 | 2.87 / 62.50 | 2 | 3 |
6 | 8 | 0.32 | 165 | 15.30 | 273 | 689 | 3.55 / 63.19 | 2 | 16 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 27 | 15.25 | 425 | 175 | 0.17 / 56.27 | 2 | 6 |
2 | 7 | 2002.96 | 38 | 14.79 | 2918 | 1640 | 1.81 / 57.91 | 2 | 3 |
3 | 13 | 1185.56 | 18 | 15.01 | 1904 | 514 | 2.33 / 58.42 | 2 | 5 |
4 | 13 | 701.96 | 18 | 15.13 | 1273 | 347 | 2.68 / 58.77 | 2 | 4 |
5 | 13 | 240.36 | 18 | 15.27 | 629 | 173 | 2.85 / 58.94 | 2 | 4 |
6 | 8 | 0.44 | 165 | 15.29 | 275 | 694 | 3.54 / 59.63 | 2 | 19 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 27 | 15.26 | 408 | 168 | 0.17 / 52.72 | 2 | 3 |
2 | 7 | 2003.60 | 38 | 14.80 | 2939 | 1653 | 1.82 / 54.37 | 2 | 3 |
3 | 13 | 1218.56 | 18 | 15.00 | 1947 | 526 | 2.35 / 54.89 | 2 | 5 |
4 | 13 | 684.64 | 18 | 15.14 | 1245 | 339 | 2.69 / 55.23 | 2 | 4 |
5 | 13 | 230.32 | 18 | 15.27 | 613 | 168 | 2.85 / 55.40 | 2 | 4 |
6 | 8 | -0.20 | 165 | 15.29 | 273 | 689 | 3.54 / 56.09 | 2 | 11 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 27 | 15.27 | 424 | 175 | 0.17 / 49.12 | 2 | 2 |
2 | 7 | 2007.52 | 39 | 14.80 | 2936 | 1695 | 1.87 / 50.82 | 2 | 3 |
3 | 13 | 1227.24 | 18 | 15.02 | 1953 | 528 | 2.40 / 51.35 | 2 | 5 |
4 | 13 | 659.24 | 18 | 15.16 | 1209 | 330 | 2.73 / 51.68 | 2 | 4 |
5 | 13 | 256.36 | 18 | 15.28 | 651 | 179 | 2.91 / 51.86 | 2 | 3 |
6 | 8 | -0.24 | 165 | 15.31 | 274 | 692 | 3.60 / 52.55 | 2 | 12 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 27 | 15.27 | 423 | 174 | 0.17 / 45.51 | 2 | 2 |
2 | 7 | 2009.04 | 39 | 14.80 | 2931 | 1692 | 1.87 / 47.20 | 2 | 3 |
3 | 13 | 1246.80 | 18 | 15.00 | 1977 | 534 | 2.40 / 47.73 | 2 | 3 |
4 | 13 | 657.56 | 18 | 15.16 | 1212 | 331 | 2.73 / 48.07 | 2 | 4 |
5 | 13 | 295.92 | 18 | 15.26 | 710 | 195 | 2.93 / 48.26 | 2 | 4 |
6 | 8 | 0.68 | 165 | 15.30 | 273 | 689 | 3.61 / 48.95 | 2 | 8 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 27 | 15.25 | 421 | 173 | 0.17 / 41.84 | 2 | 2 |
2 | 7 | 2003.88 | 38 | 14.81 | 2930 | 1649 | 1.82 / 43.48 | 2 | 3 |
3 | 13 | 1238.64 | 18 | 15.02 | 1968 | 532 | 2.35 / 44.02 | 2 | 5 |
4 | 13 | 698.28 | 18 | 15.15 | 1266 | 345 | 2.70 / 44.36 | 2 | 4 |
5 | 13 | 286.96 | 18 | 15.27 | 697 | 192 | 2.89 / 44.55 | 2 | 4 |
6 | 13 | 15.92 | 18 | 15.34 | 304 | 84 | 2.98 / 44.64 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.30 | 276 | 697 | 3.67 / 45.33 | 2 | 14 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 27 | 15.28 | 421 | 174 | 0.17 / 38.29 | 2 | 2 |
2 | 7 | 2002.08 | 38 | 14.81 | 2928 | 1648 | 1.82 / 39.94 | 2 | 3 |
3 | 13 | 1213.28 | 18 | 15.01 | 1951 | 527 | 2.35 / 40.46 | 2 | 5 |
4 | 13 | 674.32 | 18 | 15.15 | 1238 | 338 | 2.69 / 40.80 | 2 | 5 |
5 | 13 | 223.04 | 18 | 15.27 | 602 | 165 | 2.85 / 40.97 | 2 | 3 |
6 | 8 | -0.16 | 165 | 15.31 | 275 | 695 | 3.55 / 41.66 | 2 | 11 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 27 | 15.28 | 416 | 172 | 0.17 / 34.69 | 2 | 2 |
2 | 7 | 2003.12 | 38 | 14.82 | 2934 | 1652 | 1.82 / 36.34 | 2 | 3 |
3 | 13 | 1323.04 | 18 | 14.99 | 2086 | 563 | 2.39 / 36.90 | 2 | 5 |
4 | 13 | 768.68 | 18 | 15.12 | 1366 | 372 | 2.76 / 37.27 | 2 | 4 |
5 | 13 | 219.80 | 18 | 15.28 | 591 | 163 | 2.92 / 37.44 | 2 | 3 |
6 | 8 | -0.44 | 165 | 15.30 | 269 | 679 | 3.60 / 38.12 | 2 | 12 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.12 | 27 | 15.26 | 426 | 176 | 0.18 / 31.09 | 2 | 2 |
2 | 7 | 2006.12 | 38 | 14.81 | 2936 | 1652 | 1.83 / 32.74 | 2 | 4 |
3 | 13 | 1274.72 | 18 | 15.00 | 2037 | 550 | 2.38 / 33.29 | 2 | 6 |
4 | 13 | 661.60 | 18 | 15.16 | 1221 | 333 | 2.71 / 33.63 | 2 | 4 |
5 | 13 | 294.60 | 18 | 15.25 | 710 | 195 | 2.91 / 33.82 | 2 | 3 |
6 | 8 | -0.48 | 165 | 15.30 | 275 | 694 | 3.60 / 34.52 | 2 | 8 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 27 | 15.29 | 418 | 173 | 0.17 / 27.52 | 2 | 3 |
2 | 7 | 2002.64 | 38 | 14.82 | 2917 | 1643 | 1.82 / 29.16 | 2 | 4 |
3 | 13 | 1265.56 | 18 | 15.02 | 1996 | 540 | 2.35 / 29.70 | 2 | 3 |
4 | 13 | 672.16 | 18 | 15.16 | 1228 | 335 | 2.69 / 30.04 | 2 | 4 |
5 | 13 | 260.20 | 18 | 15.28 | 661 | 182 | 2.87 / 30.22 | 2 | 4 |
6 | 8 | 0.52 | 165 | 15.31 | 275 | 695 | 3.57 / 30.92 | 2 | 12 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.64 | 26 | 15.29 | 423 | 168 | 0.17 / 23.97 | 2 | 3 |
2 | 7 | 2007.60 | 38 | 14.83 | 2937 | 1655 | 1.82 / 25.62 | 2 | 4 |
3 | 13 | 1224.72 | 18 | 15.02 | 1951 | 527 | 2.35 / 26.15 | 2 | 5 |
4 | 13 | 683.68 | 18 | 15.15 | 1242 | 339 | 2.69 / 26.49 | 2 | 4 |
5 | 13 | 230.84 | 18 | 15.30 | 615 | 169 | 2.86 / 26.66 | 2 | 3 |
6 | 8 | -0.32 | 165 | 15.32 | 274 | 693 | 3.55 / 27.35 | 2 | 10 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 25 | 15.29 | 421 | 161 | 0.16 / 19.57 | 2 | 2 |
2 | 10 | 1026.84 | 2 | 15.24 | 1735 | 53 | 0.21 / 19.62 | 2 | 3 |
3 | 7 | 2007.76 | 74 | 14.71 | 2927 | 3186 | 3.40 / 22.81 | 2 | 3 |
4 | 13 | 341.36 | 18 | 15.27 | 775 | 213 | 3.61 / 23.02 | 2 | 3 |
5 | 13 | 19.68 | 18 | 15.35 | 307 | 85 | 3.70 / 23.11 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.31 | 274 | 692 | 4.39 / 23.80 | 2 | 15 |
Average= | 3.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 29 | 15.29 | 433 | 192 | 0.19 / 15.23 | 2 | 2 |
2 | 3 | 890.76 | -2 | 15.62 | 0 | 0 | 0.00 / 15.23 | 2 | 2 |
3 | 3 | 944.00 | -1 | 15.66 | 0 | 0 | 0.00 / 15.23 | 2 | 2 |
4 | 7 | 2005.08 | 74 | 14.72 | 2925 | 3186 | 3.38 / 18.41 | 2 | 4 |
5 | 13 | 330.16 | 18 | 15.27 | 759 | 209 | 3.59 / 18.62 | 2 | 3 |
6 | 13 | 16.52 | 18 | 15.34 | 305 | 84 | 3.67 / 18.71 | 2 | 3 |
7 | 8 | -0.40 | 165 | 15.32 | 277 | 700 | 4.37 / 19.41 | 2 | 12 |
Average= | 3.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 26 | 15.29 | 427 | 170 | 0.17 / 11.59 | 2 | 2 |
2 | 7 | 1524.96 | 74 | 14.92 | 2320 | 2561 | 2.73 / 14.15 | 2 | 4 |
3 | 13 | 253.48 | 18 | 15.30 | 645 | 178 | 2.91 / 14.33 | 2 | 3 |
4 | 8 | -0.44 | 165 | 15.33 | 280 | 708 | 3.62 / 15.04 | 2 | 10 |
Average= | 3.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 25 | 15.29 | 427 | 163 | 0.16 / 7.96 | 2 | 2 |
2 | 3 | 1045.92 | 1 | 15.25 | 1809 | 28 | 0.19 / 7.99 | 2 | 3 |
3 | 7 | 1523.28 | 74 | 14.92 | 2319 | 2560 | 2.75 / 10.55 | 2 | 5 |
4 | 13 | 249.52 | 18 | 15.30 | 638 | 176 | 2.93 / 10.72 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.33 | 276 | 698 | 3.63 / 11.42 | 2 | 6 |
Average= | 2.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 31 | 15.31 | 428 | 203 | 0.20 / 4.39 | 2 | 2 |
2 | 3 | 791.36 | -4 | 15.65 | 0 | 0 | 0.00 / 4.39 | 2 | 2 |
3 | 3 | 927.44 | -1 | 15.66 | 0 | 0 | 0.00 / 4.39 | 2 | 2 |
4 | 7 | 1513.24 | 74 | 14.93 | 2295 | 2536 | 2.74 / 6.92 | 2 | 4 |
5 | 13 | 232.52 | 18 | 15.32 | 613 | 169 | 2.91 / 7.09 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.33 | 277 | 701 | 3.61 / 7.79 | 2 | 10 |
Average= | 2.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 26 | 15.51 | 386 | 156 | 0.16 / 1.66 | 3 | 3 |
2 | 3 | 942.92 | -1 | 15.65 | 0 | 0 | 0.00 / 1.66 | 3 | 3 |
3 | 7 | 984.92 | 74 | 15.12 | 1610 | 1801 | 1.96 / 3.46 | 2 | 4 |
4 | 8 | 0.04 | 165 | 15.36 | 287 | 727 | 2.68 / 4.19 | 2 | 15 |
Average= | 2.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.96 | 26 | 15.62 | 409 | 166 | 0.17 / 0.17 | 3 | 3 |
2 | 7 | 130.04 | 74 | 15.60 | 413 | 477 | 0.64 / 0.64 | 3 | 4 |
3 | 8 | 0.20 | 240 | 15.56 | 230 | 859 | 1.50 / 1.50 | 3 | 15 |
Average= | 1.50 (KJ/cycle) |