SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 32 | 14.84 | 426 | 202 | 0.20 / 121.26 | 6 | 6 |
2 | 7 | 2005.64 | 40 | 14.35 | 2698 | 1549 | 1.75 / 122.81 | 6 | 12 |
3 | 13 | 1431.44 | 20 | 14.44 | 2041 | 589 | 2.34 / 123.39 | 6 | 16 |
4 | 13 | 854.36 | 20 | 14.59 | 1355 | 395 | 2.74 / 123.79 | 6 | 20 |
5 | 13 | 145.52 | 20 | 14.86 | 489 | 145 | 2.88 / 123.94 | 6 | 17 |
6 | 8 | 0.12 | 306 | 14.84 | 301 | 1367 | 4.25 / 125.30 | 6 | 139 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 31 | 14.86 | 415 | 191 | 0.19 / 117.01 | 6 | 6 |
2 | 7 | 2005.28 | 40 | 14.37 | 2687 | 1544 | 1.74 / 118.56 | 6 | 12 |
3 | 13 | 1429.24 | 20 | 14.45 | 2031 | 587 | 2.32 / 119.15 | 6 | 16 |
4 | 13 | 848.64 | 20 | 14.60 | 1348 | 394 | 2.72 / 119.54 | 6 | 18 |
5 | 13 | 146.80 | 20 | 14.86 | 490 | 146 | 2.86 / 119.69 | 6 | 16 |
6 | 13 | 13.64 | 20 | 14.91 | 321 | 96 | 2.96 / 119.78 | 6 | 15 |
7 | 8 | 0.08 | 287 | 14.84 | 299 | 1273 | 4.23 / 121.05 | 6 | 131 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 31 | 14.86 | 414 | 191 | 0.19 / 112.78 | 6 | 6 |
2 | 7 | 2008.48 | 40 | 14.36 | 2696 | 1549 | 1.74 / 114.32 | 6 | 12 |
3 | 13 | 1431.56 | 20 | 14.45 | 2040 | 590 | 2.33 / 114.91 | 6 | 16 |
4 | 13 | 857.28 | 20 | 14.59 | 1366 | 399 | 2.73 / 115.31 | 6 | 20 |
5 | 13 | 147.88 | 20 | 14.86 | 496 | 147 | 2.87 / 115.46 | 6 | 16 |
6 | 13 | 34.60 | 20 | 14.91 | 342 | 102 | 2.98 / 115.56 | 6 | 14 |
7 | 8 | 0.08 | 289 | 14.85 | 294 | 1262 | 4.24 / 116.82 | 6 | 149 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 32 | 14.85 | 425 | 202 | 0.20 / 108.58 | 6 | 6 |
2 | 7 | 2005.04 | 41 | 14.36 | 2703 | 1591 | 1.79 / 110.17 | 6 | 12 |
3 | 13 | 1328.80 | 20 | 14.47 | 1929 | 558 | 2.35 / 110.73 | 6 | 17 |
4 | 13 | 764.92 | 20 | 14.62 | 1260 | 368 | 2.72 / 111.10 | 6 | 20 |
5 | 13 | 110.28 | 20 | 14.89 | 442 | 132 | 2.85 / 111.23 | 6 | 15 |
6 | 13 | 26.08 | 20 | 14.92 | 333 | 99 | 2.95 / 111.33 | 6 | 14 |
7 | 8 | 0.04 | 287 | 14.86 | 295 | 1258 | 4.21 / 112.58 | 6 | 143 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 32 | 14.85 | 442 | 210 | 0.21 / 104.36 | 6 | 6 |
2 | 7 | 2003.92 | 40 | 14.36 | 2706 | 1554 | 1.76 / 105.92 | 6 | 12 |
3 | 13 | 1404.16 | 20 | 14.46 | 2016 | 583 | 2.35 / 106.50 | 6 | 16 |
4 | 13 | 733.24 | 20 | 14.64 | 1220 | 357 | 2.70 / 106.86 | 6 | 20 |
5 | 13 | 144.92 | 20 | 14.87 | 485 | 144 | 2.85 / 107.00 | 6 | 17 |
6 | 13 | 34.56 | 20 | 14.91 | 346 | 103 | 2.95 / 107.11 | 6 | 15 |
7 | 8 | 0.20 | 287 | 14.85 | 298 | 1270 | 4.22 / 108.38 | 6 | 142 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 32 | 14.86 | 434 | 206 | 0.21 / 100.07 | 6 | 6 |
2 | 7 | 2003.36 | 40 | 14.38 | 2685 | 1544 | 1.75 / 101.62 | 6 | 13 |
3 | 13 | 1340.00 | 20 | 14.49 | 1936 | 561 | 2.31 / 102.18 | 6 | 16 |
4 | 13 | 888.04 | 20 | 14.59 | 1407 | 411 | 2.72 / 102.59 | 6 | 19 |
5 | 13 | 164.00 | 20 | 14.87 | 511 | 152 | 2.87 / 102.74 | 6 | 17 |
6 | 13 | 43.08 | 20 | 14.91 | 363 | 108 | 2.98 / 102.85 | 6 | 15 |
7 | 8 | 0.12 | 289 | 14.85 | 304 | 1305 | 4.29 / 104.15 | 6 | 142 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 32 | 14.88 | 425 | 202 | 0.20 / 95.83 | 6 | 6 |
2 | 7 | 2003.52 | 40 | 14.38 | 2686 | 1545 | 1.75 / 97.38 | 6 | 12 |
3 | 13 | 1408.00 | 20 | 14.48 | 2005 | 581 | 2.33 / 97.96 | 6 | 16 |
4 | 13 | 825.48 | 20 | 14.62 | 1323 | 387 | 2.71 / 98.34 | 6 | 20 |
5 | 13 | 121.52 | 20 | 14.89 | 462 | 138 | 2.85 / 98.48 | 6 | 15 |
6 | 13 | 30.72 | 20 | 14.93 | 342 | 102 | 2.95 / 98.58 | 6 | 14 |
7 | 8 | 0.12 | 287 | 14.86 | 301 | 1284 | 4.24 / 99.87 | 6 | 133 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 32 | 14.87 | 433 | 206 | 0.21 / 91.57 | 6 | 6 |
2 | 7 | 2008.52 | 40 | 14.38 | 2705 | 1556 | 1.76 / 93.12 | 6 | 11 |
3 | 13 | 1312.44 | 20 | 14.51 | 1901 | 552 | 2.31 / 93.67 | 6 | 16 |
4 | 13 | 853.08 | 20 | 14.61 | 1351 | 395 | 2.71 / 94.07 | 6 | 19 |
5 | 13 | 141.04 | 20 | 14.88 | 490 | 146 | 2.85 / 94.21 | 6 | 16 |
6 | 13 | 31.52 | 20 | 14.92 | 352 | 105 | 2.96 / 94.32 | 6 | 15 |
7 | 8 | 0.04 | 289 | 14.86 | 305 | 1310 | 4.27 / 95.63 | 6 | 148 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 32 | 14.89 | 419 | 200 | 0.20 / 87.27 | 6 | 6 |
2 | 7 | 2002.76 | 40 | 14.38 | 2717 | 1563 | 1.76 / 88.83 | 6 | 12 |
3 | 13 | 1406.80 | 20 | 14.48 | 2015 | 584 | 2.35 / 89.41 | 6 | 16 |
4 | 13 | 919.52 | 20 | 14.59 | 1446 | 422 | 2.77 / 89.84 | 6 | 20 |
5 | 13 | 112.04 | 20 | 14.91 | 449 | 134 | 2.90 / 89.97 | 6 | 15 |
6 | 13 | 13.08 | 20 | 14.94 | 324 | 97 | 3.00 / 90.07 | 6 | 15 |
7 | 8 | -0.04 | 287 | 14.87 | 303 | 1293 | 4.29 / 91.36 | 6 | 144 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 32 | 14.89 | 421 | 201 | 0.20 / 83.08 | 6 | 6 |
2 | 7 | 2005.68 | 40 | 14.38 | 2717 | 1563 | 1.76 / 84.64 | 6 | 11 |
3 | 13 | 1331.28 | 20 | 14.50 | 1937 | 562 | 2.33 / 85.20 | 6 | 17 |
4 | 13 | 782.40 | 20 | 14.64 | 1281 | 375 | 2.70 / 85.58 | 6 | 21 |
5 | 13 | 103.68 | 20 | 14.91 | 430 | 128 | 2.83 / 85.71 | 6 | 15 |
6 | 13 | 31.40 | 20 | 14.94 | 340 | 102 | 2.93 / 85.81 | 6 | 14 |
7 | 8 | 0.08 | 287 | 14.88 | 295 | 1260 | 4.19 / 87.07 | 6 | 152 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 32 | 14.88 | 437 | 208 | 0.21 / 78.83 | 6 | 6 |
2 | 7 | 2005.12 | 40 | 14.39 | 2705 | 1557 | 1.77 / 80.39 | 6 | 11 |
3 | 13 | 1323.04 | 20 | 14.51 | 1920 | 557 | 2.32 / 80.95 | 6 | 16 |
4 | 13 | 869.44 | 20 | 14.62 | 1381 | 404 | 2.73 / 81.35 | 6 | 20 |
5 | 13 | 150.44 | 20 | 14.89 | 494 | 147 | 2.87 / 81.50 | 6 | 16 |
6 | 13 | 44.28 | 20 | 14.93 | 359 | 107 | 2.98 / 81.60 | 6 | 14 |
7 | 8 | 0.08 | 287 | 14.88 | 298 | 1273 | 4.25 / 82.88 | 6 | 143 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 32 | 14.90 | 418 | 199 | 0.20 / 74.56 | 6 | 6 |
2 | 7 | 2006.28 | 40 | 14.40 | 2699 | 1555 | 1.75 / 76.11 | 6 | 11 |
3 | 13 | 1427.28 | 20 | 14.50 | 2029 | 588 | 2.34 / 76.70 | 6 | 16 |
4 | 13 | 848.12 | 20 | 14.64 | 1349 | 395 | 2.74 / 77.10 | 6 | 20 |
5 | 13 | 147.24 | 20 | 14.90 | 494 | 147 | 2.88 / 77.24 | 6 | 16 |
6 | 13 | 42.36 | 20 | 14.94 | 354 | 106 | 2.99 / 77.35 | 6 | 14 |
7 | 8 | 0.12 | 289 | 14.89 | 296 | 1274 | 4.26 / 78.62 | 6 | 152 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.64 | 32 | 14.89 | 428 | 204 | 0.20 / 70.32 | 6 | 6 |
2 | 7 | 2003.32 | 40 | 14.40 | 2690 | 1549 | 1.75 / 71.87 | 6 | 11 |
3 | 13 | 1399.64 | 20 | 14.50 | 2010 | 583 | 2.34 / 72.46 | 6 | 16 |
4 | 13 | 827.44 | 20 | 14.64 | 1337 | 391 | 2.73 / 72.85 | 6 | 20 |
5 | 13 | 128.52 | 20 | 14.91 | 474 | 141 | 2.87 / 72.99 | 6 | 16 |
6 | 13 | 46.12 | 20 | 14.94 | 368 | 110 | 2.98 / 73.10 | 6 | 14 |
7 | 8 | 0.12 | 287 | 14.89 | 295 | 1261 | 4.24 / 74.36 | 6 | 143 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 32 | 14.89 | 435 | 207 | 0.21 / 65.99 | 6 | 6 |
2 | 7 | 2004.36 | 41 | 14.40 | 2708 | 1599 | 1.81 / 67.59 | 6 | 11 |
3 | 13 | 1410.00 | 20 | 14.50 | 2031 | 589 | 2.40 / 68.18 | 6 | 16 |
4 | 13 | 927.36 | 20 | 14.61 | 1452 | 424 | 2.82 / 68.61 | 6 | 20 |
5 | 13 | 116.36 | 20 | 14.92 | 451 | 135 | 2.95 / 68.74 | 6 | 15 |
6 | 13 | 65.60 | 20 | 14.93 | 385 | 115 | 3.07 / 68.86 | 6 | 14 |
7 | 8 | 0.12 | 287 | 14.89 | 296 | 1265 | 4.33 / 70.12 | 6 | 135 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 31 | 14.91 | 425 | 196 | 0.20 / 61.79 | 6 | 6 |
2 | 7 | 2006.88 | 40 | 14.41 | 2705 | 1559 | 1.76 / 63.35 | 6 | 12 |
3 | 13 | 1321.80 | 20 | 14.53 | 1922 | 559 | 2.31 / 63.90 | 6 | 16 |
4 | 13 | 783.12 | 20 | 14.66 | 1281 | 376 | 2.69 / 64.28 | 6 | 20 |
5 | 13 | 118.28 | 20 | 14.92 | 451 | 135 | 2.82 / 64.41 | 6 | 15 |
6 | 13 | 64.76 | 20 | 14.94 | 383 | 114 | 2.94 / 64.53 | 6 | 15 |
7 | 13 | 15.48 | 20 | 14.94 | 328 | 98 | 3.04 / 64.63 | 6 | 16 |
8 | 8 | 0.12 | 265 | 14.89 | 294 | 1160 | 4.20 / 65.79 | 6 | 132 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.96 | 31 | 14.90 | 425 | 196 | 0.20 / 57.56 | 6 | 6 |
2 | 7 | 2003.04 | 40 | 14.41 | 2707 | 1560 | 1.76 / 59.12 | 6 | 11 |
3 | 13 | 1311.96 | 20 | 14.53 | 1904 | 553 | 2.31 / 59.67 | 6 | 16 |
4 | 13 | 855.28 | 20 | 14.64 | 1371 | 401 | 2.71 / 60.07 | 6 | 20 |
5 | 13 | 140.24 | 20 | 14.91 | 476 | 142 | 2.85 / 60.22 | 6 | 17 |
6 | 13 | 47.44 | 20 | 14.94 | 362 | 108 | 2.96 / 60.32 | 6 | 15 |
7 | 8 | 0.12 | 287 | 14.90 | 296 | 1266 | 4.23 / 61.59 | 6 | 148 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 31 | 14.90 | 432 | 200 | 0.20 / 53.33 | 6 | 6 |
2 | 7 | 2010.00 | 40 | 14.41 | 2708 | 1561 | 1.76 / 54.89 | 6 | 12 |
3 | 13 | 1314.64 | 20 | 14.54 | 1918 | 558 | 2.32 / 55.45 | 6 | 17 |
4 | 13 | 853.52 | 20 | 14.64 | 1368 | 401 | 2.72 / 55.85 | 6 | 20 |
5 | 13 | 135.96 | 20 | 14.91 | 481 | 143 | 2.86 / 55.99 | 6 | 17 |
6 | 13 | 45.40 | 20 | 14.95 | 361 | 108 | 2.97 / 56.10 | 6 | 15 |
7 | 8 | 0.12 | 285 | 14.90 | 297 | 1261 | 4.23 / 57.36 | 6 | 133 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 31 | 14.91 | 422 | 195 | 0.20 / 49.11 | 6 | 6 |
2 | 7 | 2004.36 | 41 | 14.42 | 2685 | 1587 | 1.78 / 50.69 | 6 | 12 |
3 | 13 | 1325.68 | 20 | 14.54 | 1917 | 557 | 2.34 / 51.25 | 6 | 17 |
4 | 13 | 775.76 | 20 | 14.67 | 1268 | 372 | 2.71 / 51.62 | 6 | 20 |
5 | 13 | 108.96 | 20 | 14.93 | 445 | 133 | 2.84 / 51.76 | 6 | 16 |
6 | 13 | 38.96 | 20 | 14.95 | 356 | 106 | 2.95 / 51.86 | 6 | 15 |
7 | 8 | 0.08 | 285 | 14.90 | 299 | 1270 | 4.22 / 53.13 | 6 | 134 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.64 | 31 | 14.91 | 442 | 204 | 0.20 / 44.94 | 6 | 6 |
2 | 7 | 2003.60 | 40 | 14.43 | 2689 | 1552 | 1.76 / 46.49 | 6 | 12 |
3 | 13 | 1310.40 | 20 | 14.55 | 1901 | 553 | 2.31 / 47.05 | 6 | 17 |
4 | 13 | 760.00 | 20 | 14.69 | 1252 | 368 | 2.68 / 47.41 | 6 | 20 |
5 | 13 | 102.68 | 20 | 14.94 | 432 | 129 | 2.81 / 47.54 | 6 | 16 |
6 | 13 | 36.56 | 20 | 14.96 | 350 | 105 | 2.91 / 47.65 | 6 | 15 |
7 | 8 | 0.12 | 285 | 14.91 | 297 | 1262 | 4.17 / 48.91 | 6 | 137 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.84 | 31 | 14.92 | 432 | 200 | 0.20 / 40.67 | 6 | 6 |
2 | 7 | 2002.88 | 40 | 14.43 | 2698 | 1557 | 1.76 / 42.23 | 6 | 12 |
3 | 13 | 1328.68 | 20 | 14.55 | 1920 | 559 | 2.32 / 42.79 | 6 | 17 |
4 | 13 | 862.64 | 20 | 14.65 | 1375 | 403 | 2.72 / 43.19 | 6 | 20 |
5 | 13 | 160.00 | 20 | 14.91 | 513 | 153 | 2.87 / 43.35 | 6 | 18 |
6 | 13 | 44.84 | 20 | 14.96 | 365 | 109 | 2.98 / 43.46 | 6 | 16 |
7 | 13 | 12.80 | 20 | 14.96 | 325 | 97 | 3.08 / 43.55 | 6 | 17 |
8 | 8 | 0.08 | 265 | 14.90 | 300 | 1185 | 4.26 / 44.74 | 6 | 131 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.28 | 31 | 14.92 | 445 | 206 | 0.21 / 36.40 | 6 | 6 |
2 | 7 | 2003.68 | 40 | 14.44 | 2704 | 1562 | 1.77 / 37.96 | 8 | 11 |
3 | 13 | 1314.64 | 20 | 14.55 | 1915 | 557 | 2.32 / 38.52 | 6 | 17 |
4 | 13 | 856.36 | 20 | 14.65 | 1374 | 403 | 2.73 / 38.92 | 6 | 20 |
5 | 13 | 151.88 | 20 | 14.92 | 508 | 152 | 2.88 / 39.07 | 6 | 18 |
6 | 13 | 41.12 | 20 | 14.96 | 358 | 107 | 2.99 / 39.18 | 6 | 16 |
7 | 13 | 16.24 | 20 | 14.96 | 336 | 101 | 3.09 / 39.28 | 6 | 16 |
8 | 8 | 0.12 | 265 | 14.90 | 302 | 1192 | 4.28 / 40.47 | 6 | 136 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 31 | 14.92 | 424 | 196 | 0.20 / 32.07 | 6 | 7 |
2 | 7 | 2003.48 | 41 | 14.43 | 2701 | 1598 | 1.79 / 33.67 | 7 | 11 |
3 | 13 | 1312.88 | 20 | 14.55 | 1921 | 559 | 2.35 / 34.23 | 6 | 17 |
4 | 13 | 857.92 | 20 | 14.66 | 1383 | 405 | 2.76 / 34.64 | 6 | 20 |
5 | 13 | 145.64 | 20 | 14.93 | 494 | 148 | 2.91 / 34.78 | 6 | 17 |
6 | 13 | 46.04 | 20 | 14.97 | 365 | 109 | 3.02 / 34.89 | 6 | 14 |
7 | 13 | 26.12 | 20 | 14.97 | 336 | 101 | 3.12 / 34.99 | 6 | 15 |
8 | 8 | 0.04 | 268 | 14.91 | 301 | 1203 | 4.32 / 36.20 | 6 | 152 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 31 | 14.92 | 421 | 195 | 0.19 / 27.81 | 6 | 6 |
2 | 7 | 2008.92 | 40 | 14.44 | 2728 | 1576 | 1.77 / 29.38 | 6 | 11 |
3 | 13 | 1316.80 | 20 | 14.56 | 1915 | 558 | 2.33 / 29.94 | 6 | 16 |
4 | 13 | 757.76 | 20 | 14.70 | 1257 | 370 | 2.70 / 30.31 | 6 | 20 |
5 | 13 | 164.32 | 20 | 14.92 | 521 | 155 | 2.85 / 30.47 | 6 | 17 |
6 | 13 | 49.00 | 20 | 14.97 | 368 | 110 | 2.96 / 30.58 | 6 | 14 |
7 | 13 | 32.16 | 20 | 14.97 | 344 | 103 | 3.07 / 30.68 | 6 | 14 |
8 | 13 | 17.12 | 20 | 14.97 | 327 | 98 | 3.16 / 30.78 | 6 | 14 |
9 | 8 | 0.16 | 246 | 14.91 | 300 | 1100 | 4.26 / 31.88 | 6 | 130 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 31 | 14.93 | 409 | 189 | 0.19 / 23.53 | 6 | 6 |
2 | 3 | 1020.92 | 1 | 14.98 | 1579 | 24 | 0.21 / 23.55 | 6 | 7 |
3 | 7 | 2008.24 | 41 | 14.45 | 2698 | 1598 | 1.81 / 25.15 | 7 | 11 |
4 | 13 | 1327.48 | 20 | 14.56 | 1923 | 560 | 2.37 / 25.71 | 6 | 16 |
5 | 13 | 764.44 | 20 | 14.70 | 1253 | 368 | 2.74 / 26.08 | 6 | 20 |
6 | 13 | 114.36 | 20 | 14.96 | 449 | 134 | 2.87 / 26.21 | 6 | 15 |
7 | 13 | 62.44 | 20 | 14.97 | 385 | 115 | 2.99 / 26.33 | 6 | 14 |
8 | 13 | 26.16 | 20 | 14.98 | 341 | 102 | 3.09 / 26.43 | 6 | 14 |
9 | 8 | 0.08 | 267 | 14.92 | 297 | 1183 | 4.27 / 27.61 | 6 | 141 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.00 | 31 | 14.94 | 425 | 197 | 0.20 / 19.26 | 6 | 6 |
2 | 7 | 2002.48 | 41 | 14.45 | 2702 | 1601 | 1.80 / 20.86 | 6 | 12 |
3 | 13 | 1293.04 | 20 | 14.57 | 1885 | 549 | 2.35 / 21.41 | 6 | 17 |
4 | 13 | 829.84 | 20 | 14.67 | 1352 | 397 | 2.74 / 21.81 | 6 | 20 |
5 | 13 | 121.48 | 20 | 14.95 | 463 | 138 | 2.88 / 21.95 | 6 | 16 |
6 | 13 | 42.04 | 20 | 14.98 | 360 | 108 | 2.99 / 22.05 | 6 | 14 |
7 | 13 | 24.24 | 20 | 14.98 | 335 | 100 | 3.09 / 22.15 | 6 | 14 |
8 | 8 | -0.04 | 267 | 14.92 | 297 | 1183 | 4.27 / 23.34 | 6 | 141 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.12 | 33 | 14.94 | 426 | 210 | 0.21 / 15.44 | 6 | 6 |
2 | 3 | 928.20 | -1 | 15.40 | 17 | 0 | 0.00 / 15.44 | 6 | 6 |
3 | 7 | 1524.88 | 40 | 14.66 | 2166 | 1270 | 1.48 / 16.71 | 6 | 12 |
4 | 13 | 1136.36 | 20 | 14.67 | 1710 | 502 | 1.98 / 17.22 | 6 | 15 |
5 | 13 | 687.12 | 20 | 14.76 | 1172 | 346 | 2.33 / 17.56 | 6 | 19 |
6 | 13 | 100.32 | 20 | 14.97 | 432 | 129 | 2.46 / 17.69 | 6 | 15 |
7 | 13 | 29.72 | 20 | 14.99 | 349 | 105 | 2.56 / 17.80 | 6 | 14 |
8 | 8 | 0.12 | 285 | 14.94 | 298 | 1269 | 3.83 / 19.06 | 6 | 142 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 41 | 14.92 | 444 | 272 | 0.27 / 11.59 | 6 | 6 |
2 | 3 | 739.00 | -4 | 15.41 | 17 | 0 | 0.00 / 11.59 | 6 | 6 |
3 | 7 | 1524.20 | 40 | 14.66 | 2169 | 1272 | 1.54 / 12.86 | 6 | 12 |
4 | 13 | 1218.48 | 20 | 14.66 | 1812 | 531 | 2.07 / 13.39 | 6 | 15 |
5 | 13 | 753.08 | 20 | 14.74 | 1258 | 371 | 2.45 / 13.76 | 6 | 19 |
6 | 13 | 91.60 | 20 | 14.99 | 406 | 122 | 2.57 / 13.89 | 6 | 14 |
7 | 13 | 29.48 | 20 | 15.00 | 339 | 102 | 2.67 / 13.99 | 6 | 12 |
8 | 13 | 11.32 | 20 | 15.00 | 313 | 94 | 2.76 / 14.08 | 6 | 13 |
9 | 8 | 0.08 | 263 | 14.94 | 293 | 1151 | 3.91 / 15.23 | 6 | 134 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.20 | 31 | 14.84 | 420 | 193 | 0.19 / 7.42 | 6 | 6 |
2 | 10 | 1078.32 | 7 | 14.83 | 1633 | 170 | 0.36 / 7.59 | 6 | 7 |
3 | 10 | 1111.68 | 3 | 14.83 | 1670 | 74 | 0.44 / 7.66 | 6 | 7 |
4 | 3 | 1086.08 | 2 | 14.89 | 1644 | 49 | 0.49 / 7.71 | 6 | 11 |
5 | 7 | 1522.68 | 40 | 14.66 | 2155 | 1264 | 1.75 / 8.97 | 11 | 11 |
6 | 13 | 1207.76 | 20 | 14.66 | 1789 | 525 | 2.27 / 9.50 | 6 | 15 |
7 | 13 | 631.00 | 20 | 14.78 | 1107 | 327 | 2.60 / 9.83 | 6 | 19 |
8 | 13 | 90.44 | 20 | 14.98 | 424 | 127 | 2.73 / 9.95 | 6 | 13 |
9 | 13 | 26.32 | 20 | 14.99 | 343 | 103 | 2.83 / 10.06 | 6 | 13 |
10 | 8 | 0.24 | 282 | 14.93 | 300 | 1263 | 4.09 / 11.32 | 6 | 137 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.00 | 31 | 15.04 | 394 | 184 | 0.18 / 1.86 | 7 | 7 |
2 | 10 | 1023.76 | 5 | 14.90 | 1535 | 114 | 0.30 / 1.97 | 6 | 7 |
3 | 10 | 1063.68 | 4 | 14.88 | 1604 | 95 | 0.39 / 2.07 | 6 | 7 |
4 | 3 | 1086.32 | 2 | 14.91 | 1639 | 49 | 0.44 / 2.11 | 6 | 10 |
5 | 7 | 1535.28 | 40 | 14.61 | 2180 | 1274 | 1.72 / 3.39 | 10 | 11 |
6 | 13 | 1348.76 | 20 | 14.60 | 1962 | 573 | 2.29 / 3.96 | 6 | 12 |
7 | 13 | 1034.32 | 20 | 14.64 | 1584 | 464 | 2.75 / 4.43 | 6 | 15 |
8 | 13 | 587.44 | 20 | 14.77 | 1048 | 310 | 3.06 / 4.74 | 6 | 18 |
9 | 8 | 200.56 | 344 | 14.77 | 490 | 2490 | 5.55 / 7.22 | 6 | 138 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 97.76 | 30 | 15.31 | 372 | 171 | 0.17 / 0.17 | 7 | 7 |
2 | 7 | 111.84 | 40 | 15.28 | 377 | 230 | 0.40 / 0.40 | 7 | 7 |
3 | 13 | 74.20 | 20 | 15.26 | 335 | 102 | 0.50 / 0.50 | 6 | 7 |
4 | 13 | 18.52 | 20 | 15.25 | 267 | 81 | 0.58 / 0.58 | 6 | 7 |
5 | 8 | 0.28 | 295 | 15.17 | 243 | 1087 | 1.67 / 1.67 | 7 | 156 |
Average= | 1.67 (KJ/cycle) |