SIO Argo Site:
Pump Diagnostics Page   



Serial= 7832 WMO= 3902257

Return

←PreviousNext→

Cycle 27 GMT 24/11/2024 9:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 35 14.83 442 229 0.23 / 120.58 5 5
2 3 1035.84 1 14.80 1699 25 0.25 / 120.61 5 7
3 7 2007.64 40 14.39 3009 1732 1.99 / 122.34 7 8
4 13 1356.44 20 14.49 2165 627 2.61 / 122.96 5 10
5 13 1016.40 20 14.54 1712 498 3.11 / 123.46 5 12
6 13 194.92 20 14.83 589 175 3.29 / 123.64 5 11
7 8 0.24 314 14.84 309 1440 4.73 / 125.08 5 179
Average= 4.47
(KJ/cycle)

Cycle 26 GMT 14/11/2024 3:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 35 14.83 436 226 0.23 / 115.90 5 5
2 7 2009.44 40 14.40 2993 1724 1.95 / 117.62 5 8
3 13 1438.96 20 14.47 2272 658 2.61 / 118.28 5 11
4 13 987.24 20 14.56 1674 487 3.10 / 118.77 5 14
5 13 184.96 20 14.84 568 169 3.26 / 118.94 5 10
6 8 0.24 314 14.85 303 1413 4.68 / 120.35 5 158
Average= 4.46
(KJ/cycle)

Cycle 25 GMT 3/11/2024 21:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 36 14.82 457 244 0.24 / 111.18 5 5
2 3 957.84 -1 15.26 0 0 0.00 / 111.18 5 5
3 7 2004.20 40 14.41 2983 1719 1.96 / 112.90 5 7
4 13 1441.20 20 14.49 2235 648 2.61 / 113.55 5 11
5 13 988.56 20 14.57 1675 488 3.10 / 114.04 5 13
6 13 283.64 20 14.81 717 212 3.31 / 114.25 5 12
7 8 0.12 314 14.85 305 1422 4.73 / 115.67 5 136
Average= 4.45
(KJ/cycle)

Cycle 24 GMT 24/10/2024 15: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 37 14.82 461 253 0.25 / 106.37 5 5
2 7 2006.32 40 14.40 3015 1737 1.99 / 108.11 5 8
3 13 1546.96 20 14.45 2431 703 2.69 / 108.81 5 9
4 13 967.64 20 14.58 1657 483 3.18 / 109.29 5 13
5 13 286.52 20 14.81 716 212 3.39 / 109.51 5 12
6 8 0.20 314 14.84 308 1435 4.82 / 110.94 5 148
Average= 4.44
(KJ/cycle)

Cycle 23 GMT 14/10/2024 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 37 14.82 459 252 0.25 / 101.64 5 5
2 7 2007.44 40 14.41 3008 1734 1.99 / 103.37 5 7
3 13 1444.36 20 14.48 2281 661 2.65 / 104.03 5 10
4 13 906.44 20 14.60 1576 460 3.11 / 104.49 5 13
5 13 217.68 20 14.83 622 184 3.29 / 104.68 5 11
6 8 0.04 314 14.85 309 1441 4.73 / 106.12 5 182
Average= 4.42
(KJ/cycle)

Cycle 22 GMT 4/10/2024 2:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 36 14.83 452 241 0.24 / 96.92 5 5
2 3 1025.84 1 14.84 1704 25 0.27 / 96.94 5 5
3 7 2003.76 40 14.41 3009 1734 2.00 / 98.68 5 7
4 13 1454.52 20 14.49 2262 656 2.66 / 99.33 5 9
5 13 816.56 20 14.64 1452 425 3.08 / 99.76 5 12
6 13 241.20 20 14.83 647 192 3.27 / 99.95 5 11
7 8 0.16 314 14.85 308 1436 4.71 / 101.39 5 168
Average= 4.41
(KJ/cycle)

Cycle 21 GMT 23/ 9/2024 19:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 36 14.83 475 254 0.25 / 92.24 5 5
2 7 2006.00 40 14.43 2954 1705 1.96 / 93.94 5 7
3 13 1449.32 20 14.50 2274 659 2.62 / 94.60 5 9
4 13 897.68 20 14.61 1560 456 3.07 / 95.06 5 12
5 13 212.20 20 14.85 614 182 3.26 / 95.24 5 10
6 8 0.20 314 14.86 308 1437 4.69 / 96.68 5 171
Average= 4.39
(KJ/cycle)

Cycle 20 GMT 13/ 9/2024 13:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 36 14.83 462 247 0.25 / 87.50 5 5
2 7 2005.24 40 14.44 2969 1715 1.96 / 89.22 5 6
3 13 1443.32 20 14.50 2267 657 2.62 / 89.87 5 9
4 13 1000.56 20 14.59 1692 494 3.11 / 90.37 5 12
5 13 206.16 20 14.86 600 178 3.29 / 90.55 5 10
6 8 0.20 314 14.87 308 1438 4.73 / 91.98 5 156
Average= 4.38
(KJ/cycle)

Cycle 19 GMT 3/ 9/2024 7:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 36 14.84 463 247 0.25 / 82.78 5 5
2 7 2006.76 41 14.43 2972 1758 2.01 / 84.54 5 7
3 13 1442.12 20 14.50 2268 658 2.66 / 85.20 5 10
4 13 975.20 20 14.59 1672 488 3.15 / 85.69 5 12
5 13 170.84 20 14.87 543 161 3.31 / 85.85 5 9
6 8 0.20 315 14.87 300 1405 4.72 / 87.25 5 169
Average= 4.36
(KJ/cycle)

Cycle 18 GMT 24/ 8/2024 1: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 36 14.85 462 247 0.25 / 78.13 5 5
2 7 2005.96 40 14.44 2967 1714 1.96 / 79.84 5 6
3 13 1535.16 20 14.51 2329 676 2.64 / 80.52 5 9
4 13 876.00 20 14.64 1533 449 3.09 / 80.96 5 11
5 13 219.88 20 14.86 616 183 3.27 / 81.15 5 9
6 8 0.08 312 14.88 299 1388 4.66 / 82.54 5 141
Average= 4.34
(KJ/cycle)

Cycle 17 GMT 13/ 8/2024 18:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 37 14.85 460 253 0.25 / 73.45 5 5
2 7 2007.88 40 14.45 2961 1711 1.96 / 75.17 5 6
3 13 1452.32 20 14.52 2288 664 2.63 / 75.83 5 9
4 13 903.04 20 14.64 1558 456 3.08 / 76.29 5 11
5 13 218.12 20 14.87 608 181 3.27 / 76.47 5 9
6 8 0.16 312 14.89 304 1412 4.68 / 77.88 5 147
Average= 4.33
(KJ/cycle)

Cycle 16 GMT 3/ 8/2024 12:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 36 14.86 447 239 0.24 / 68.65 5 5
2 3 1042.16 1 14.86 1717 26 0.26 / 68.68 5 6
3 7 2005.52 41 14.45 2998 1776 2.04 / 70.45 6 6
4 13 1462.24 20 14.50 2318 672 2.71 / 71.13 5 9
5 13 907.88 20 14.63 1576 461 3.17 / 71.59 5 12
6 13 217.84 20 14.87 618 184 3.36 / 71.77 5 9
7 13 23.64 20 14.93 338 101 3.46 / 71.87 5 8
8 8 0.00 293 14.88 305 1330 4.79 / 73.20 5 149
Average= 4.31
(KJ/cycle)

Cycle 15 GMT 24/ 7/2024 5:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 36 14.85 469 251 0.25 / 63.82 5 5
2 7 2003.44 40 14.46 2984 1726 1.98 / 65.54 5 6
3 13 1652.00 20 14.48 2544 737 2.71 / 66.28 5 8
4 13 1041.88 20 14.59 1751 511 3.22 / 66.79 5 11
5 13 241.72 20 14.87 643 191 3.42 / 66.98 5 9
6 8 0.28 314 14.89 306 1431 4.85 / 68.41 5 139
Average= 4.28
(KJ/cycle)

Cycle 14 GMT 13/ 7/2024 23:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 36 14.86 454 243 0.24 / 59.01 5 5
2 7 2005.84 40 14.47 2970 1719 1.96 / 60.73 5 7
3 13 1552.56 20 14.51 2390 694 2.66 / 61.42 5 9
4 13 990.92 20 14.62 1659 485 3.14 / 61.91 5 11
5 13 315.60 20 14.83 755 224 3.36 / 62.13 5 10
6 8 0.04 314 14.88 307 1434 4.80 / 63.57 5 146
Average= 4.24
(KJ/cycle)

Cycle 13 GMT 3/ 7/2024 17:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 36 14.86 457 244 0.24 / 54.21 5 5
2 7 2005.60 40 14.46 2993 1731 1.98 / 55.94 5 6
3 13 1562.32 20 14.50 2446 709 2.68 / 56.65 5 8
4 13 978.28 20 14.62 1670 488 3.17 / 57.14 5 11
5 13 278.84 20 14.85 702 208 3.38 / 57.35 5 9
6 8 0.08 314 14.89 303 1417 4.80 / 58.77 5 169
Average= 4.20
(KJ/cycle)

Cycle 12 GMT 23/ 6/2024 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 36 14.85 472 252 0.25 / 49.44 5 5
2 7 2008.60 40 14.46 3006 1739 1.99 / 51.18 5 6
3 13 1532.28 20 14.52 2407 699 2.69 / 51.88 5 8
4 13 951.44 20 14.63 1622 475 3.16 / 52.35 5 11
5 13 249.96 20 14.86 663 197 3.36 / 52.55 5 10
6 8 0.20 312 14.89 306 1422 4.78 / 53.97 5 148
Average= 4.15
(KJ/cycle)

Cycle 11 GMT 13/ 6/2024 5:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 36 14.88 442 237 0.24 / 44.66 5 5
2 7 2003.92 40 14.46 3009 1740 1.98 / 46.40 5 6
3 13 1456.04 20 14.53 2284 664 2.64 / 47.06 5 9
4 13 988.56 20 14.61 1688 493 3.13 / 47.56 5 11
5 13 185.16 20 14.88 573 171 3.30 / 47.73 5 9
6 8 0.20 314 14.89 312 1459 4.76 / 49.19 5 182
Average= 4.10
(KJ/cycle)

Cycle 10 GMT 2/ 6/2024 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 36 14.89 447 240 0.24 / 40.34 5 5
2 7 1480.68 40 14.65 2317 1358 1.60 / 41.70 5 8
3 13 1387.88 20 14.63 2220 650 2.25 / 42.35 5 9
4 13 933.92 20 14.70 1603 471 2.72 / 42.82 5 11
5 13 211.92 20 14.91 608 181 2.90 / 43.00 5 9
6 8 0.36 310 14.92 307 1420 4.32 / 44.42 5 144
Average= 4.04
(KJ/cycle)

Cycle 9 GMT 23/ 5/2024 13:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 36 14.89 443 237 0.24 / 35.98 5 5
2 7 1602.80 40 14.61 2475 1446 1.68 / 37.43 5 8
3 13 1415.32 20 14.60 2234 652 2.34 / 38.08 5 9
4 13 854.80 20 14.71 1497 440 2.78 / 38.52 5 11
5 13 162.72 20 14.92 534 159 2.94 / 38.68 5 8
6 8 0.08 312 14.92 306 1424 4.36 / 40.10 5 206
Average= 4.01
(KJ/cycle)

Cycle 8 GMT 13/ 5/2024 4:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 36 14.88 462 247 0.25 / 31.47 5 5
2 7 1783.28 40 14.54 2703 1572 1.82 / 33.04 5 7
3 13 1465.12 20 14.55 2318 675 2.49 / 33.71 5 9
4 13 898.20 20 14.68 1555 457 2.95 / 34.17 5 12
5 13 207.08 20 14.90 593 177 3.13 / 34.35 5 9
6 8 0.32 312 14.91 300 1396 4.52 / 35.74 5 165
Average= 3.97
(KJ/cycle)

Cycle 7 GMT 2/ 5/2024 18:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 34 14.86 467 236 0.24 / 26.73 5 5
2 3 1058.40 1 14.85 1733 26 0.26 / 26.76 5 7
3 7 2004.76 40 14.48 2958 1713 1.97 / 28.47 7 6
4 13 1550.76 20 14.52 2414 701 2.68 / 29.17 5 8
5 13 953.92 20 14.64 1629 477 3.15 / 29.65 5 12
6 13 167.28 20 14.91 535 160 3.31 / 29.81 5 8
7 13 43.08 20 14.95 361 108 3.42 / 29.92 5 8
8 8 0.00 295 14.91 296 1302 4.72 / 31.22 5 142
Average= 3.90
(KJ/cycle)

Cycle 6 GMT 22/ 4/2024 12:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 33 14.87 436 214 0.21 / 21.96 5 5
2 3 1052.84 1 14.83 1763 26 0.24 / 21.99 5 7
3 7 2009.76 40 14.48 2998 1736 1.98 / 23.73 7 7
4 13 1445.64 20 14.54 2274 661 2.64 / 24.39 5 9
5 13 984.52 20 14.62 1681 492 3.13 / 24.88 5 12
6 13 260.24 20 14.86 674 200 3.33 / 25.08 5 11
7 13 24.20 20 14.94 337 101 3.43 / 25.18 5 11
8 8 0.12 293 14.89 302 1318 4.75 / 26.50 5 215
Average= 3.79
(KJ/cycle)

Cycle 5 GMT 12/ 4/2024 6: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 31 14.89 438 202 0.20 / 17.36 5 5
2 10 1032.20 2 14.82 1702 50 0.25 / 17.41 5 5
3 7 2005.00 40 14.48 2986 1729 1.98 / 19.14 5 7
4 13 1418.60 20 14.54 2236 650 2.63 / 19.79 5 9
5 13 856.04 20 14.66 1493 438 3.07 / 20.23 5 13
6 13 93.72 20 14.92 436 130 3.20 / 20.36 5 9
7 13 18.32 20 14.94 331 99 3.30 / 20.46 5 10
8 8 0.20 291 14.89 298 1291 4.59 / 21.75 5 135
Average= 3.62
(KJ/cycle)

Cycle 4 GMT 1/ 4/2024 23:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 33 14.87 447 219 0.22 / 13.26 5 5
2 7 1506.68 40 14.66 2360 1384 1.60 / 14.64 5 7
3 13 1315.52 20 14.64 2100 615 2.22 / 15.26 5 8
4 13 847.60 20 14.70 1491 438 2.66 / 15.69 5 11
5 13 113.08 20 14.94 459 137 2.79 / 15.83 5 9
6 8 0.16 308 14.92 289 1328 4.12 / 17.16 5 137
Average= 3.43
(KJ/cycle)

Cycle 3 GMT 31/ 3/2024 14:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 33 14.88 436 214 0.21 / 9.06 5 5
2 7 1508.88 40 14.65 2368 1388 1.60 / 10.44 5 7
3 13 1411.40 20 14.62 2245 656 2.26 / 11.10 5 8
4 13 805.44 20 14.72 1433 422 2.68 / 11.52 5 11
5 13 98.36 20 14.94 444 133 2.81 / 11.66 5 9
6 8 0.20 312 14.92 297 1383 4.20 / 13.04 5 161
Average= 3.26
(KJ/cycle)

Cycle 2 GMT 30/ 3/2024 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 31 14.90 449 207 0.21 / 4.89 5 5
2 10 1003.92 3 14.83 1693 75 0.28 / 4.97 5 5
3 7 1510.20 40 14.65 2370 1389 1.67 / 6.35 5 7
4 13 1232.16 20 14.65 1999 586 2.26 / 6.94 5 8
5 13 781.40 20 14.72 1401 412 2.67 / 7.35 5 11
6 13 96.48 20 14.94 439 131 2.80 / 7.48 5 9
7 8 0.16 310 14.91 294 1359 4.16 / 8.84 5 158
Average= 2.95
(KJ/cycle)

Cycle 1 GMT 28/ 3/2024 19: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 31 15.02 429 200 0.20 / 2.11 5 5
2 3 1050.80 1 14.84 1728 26 0.23 / 2.13 5 6
3 7 1007.68 40 14.75 1701 1004 1.23 / 3.14 6 9
4 13 133.80 20 14.97 499 149 1.38 / 3.29 5 9
5 8 0.24 312 14.95 299 1395 2.77 / 4.68 5 161
Average= 2.34
(KJ/cycle)

Cycle 0 GMT 28/ 3/2024 8:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.76 30 15.20 511 233 0.23 / 0.23 5 5
2 7 173.24 40 15.18 514 312 0.55 / 0.55 5 5
3 13 87.84 20 15.17 395 120 0.66 / 0.66 5 5
4 8 0.36 306 15.12 269 1245 1.91 / 1.91 5 159
Average= 1.91
(KJ/cycle)