SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 27 | 14.68 | 513 | 203 | 0.20 / 165.00 | 6 | 7 |
2 | 7 | 2002.96 | 40 | 14.26 | 2885 | 1646 | 1.85 / 166.65 | 7 | 10 |
3 | 13 | 1258.36 | 20 | 14.40 | 1996 | 575 | 2.42 / 167.22 | 6 | 16 |
4 | 13 | 678.40 | 20 | 14.55 | 1259 | 366 | 2.79 / 167.59 | 6 | 22 |
5 | 13 | 187.88 | 20 | 14.71 | 651 | 192 | 2.98 / 167.78 | 6 | 19 |
6 | 8 | 0.00 | 321 | 14.69 | 392 | 1848 | 4.83 / 169.63 | 6 | 140 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 27 | 14.68 | 505 | 200 | 0.20 / 160.26 | 6 | 6 |
2 | 7 | 2005.24 | 40 | 14.26 | 2874 | 1639 | 1.84 / 161.90 | 6 | 11 |
3 | 13 | 1177.68 | 20 | 14.43 | 1890 | 545 | 2.38 / 162.44 | 6 | 16 |
4 | 13 | 607.12 | 20 | 14.57 | 1168 | 340 | 2.73 / 162.78 | 6 | 19 |
5 | 13 | 151.68 | 20 | 14.73 | 598 | 176 | 2.90 / 162.96 | 6 | 19 |
6 | 8 | 0.04 | 321 | 14.69 | 391 | 1844 | 4.75 / 164.80 | 6 | 140 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 27 | 14.69 | 508 | 201 | 0.20 / 155.55 | 6 | 7 |
2 | 7 | 2002.12 | 40 | 14.26 | 2872 | 1638 | 1.84 / 157.18 | 7 | 11 |
3 | 13 | 1150.56 | 20 | 14.44 | 1846 | 533 | 2.37 / 157.72 | 6 | 16 |
4 | 13 | 603.24 | 20 | 14.58 | 1158 | 338 | 2.71 / 158.06 | 6 | 21 |
5 | 13 | 126.12 | 20 | 14.75 | 558 | 165 | 2.88 / 158.22 | 6 | 17 |
6 | 8 | 0.04 | 321 | 14.70 | 389 | 1836 | 4.71 / 160.06 | 6 | 153 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 27 | 14.72 | 495 | 197 | 0.20 / 150.83 | 6 | 7 |
2 | 7 | 2002.60 | 41 | 14.27 | 2866 | 1677 | 1.87 / 152.50 | 7 | 12 |
3 | 13 | 1255.04 | 20 | 14.42 | 1957 | 564 | 2.44 / 153.07 | 6 | 17 |
4 | 13 | 574.88 | 20 | 14.60 | 1119 | 327 | 2.76 / 153.39 | 6 | 21 |
5 | 13 | 123.84 | 20 | 14.75 | 551 | 163 | 2.93 / 153.56 | 6 | 16 |
6 | 8 | -0.04 | 319 | 14.71 | 381 | 1788 | 4.72 / 155.35 | 6 | 144 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 27 | 14.71 | 494 | 196 | 0.20 / 146.05 | 6 | 7 |
2 | 7 | 2005.56 | 40 | 14.27 | 2868 | 1637 | 1.83 / 147.69 | 7 | 13 |
3 | 13 | 1274.52 | 20 | 14.42 | 1989 | 574 | 2.41 / 148.27 | 6 | 14 |
4 | 13 | 673.56 | 20 | 14.57 | 1248 | 364 | 2.77 / 148.63 | 6 | 19 |
5 | 13 | 189.44 | 20 | 14.73 | 637 | 188 | 2.96 / 148.82 | 6 | 21 |
6 | 8 | 0.00 | 321 | 14.71 | 384 | 1813 | 4.77 / 150.63 | 6 | 145 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 27 | 14.73 | 494 | 196 | 0.20 / 141.39 | 6 | 6 |
2 | 7 | 2003.04 | 40 | 14.27 | 2857 | 1631 | 1.83 / 143.02 | 6 | 12 |
3 | 13 | 1080.04 | 20 | 14.48 | 1758 | 509 | 2.34 / 143.53 | 6 | 16 |
4 | 13 | 631.52 | 20 | 14.58 | 1189 | 347 | 2.68 / 143.88 | 6 | 19 |
5 | 13 | 155.76 | 20 | 14.74 | 598 | 176 | 2.86 / 144.05 | 6 | 21 |
6 | 8 | -0.04 | 319 | 14.71 | 385 | 1807 | 4.67 / 145.86 | 6 | 136 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 27 | 14.72 | 497 | 198 | 0.20 / 136.61 | 6 | 7 |
2 | 7 | 2002.44 | 40 | 14.28 | 2855 | 1631 | 1.83 / 138.24 | 7 | 11 |
3 | 13 | 1269.04 | 20 | 14.43 | 1981 | 572 | 2.40 / 138.81 | 6 | 16 |
4 | 13 | 685.52 | 20 | 14.57 | 1250 | 364 | 2.76 / 139.18 | 6 | 17 |
5 | 13 | 195.32 | 20 | 14.74 | 643 | 190 | 2.95 / 139.37 | 6 | 19 |
6 | 8 | -0.08 | 323 | 14.72 | 384 | 1826 | 4.78 / 141.19 | 6 | 145 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.68 | 27 | 14.72 | 512 | 203 | 0.20 / 131.93 | 6 | 8 |
2 | 7 | 2009.80 | 40 | 14.28 | 2872 | 1640 | 1.84 / 133.57 | 9 | 12 |
3 | 13 | 1173.16 | 20 | 14.45 | 1862 | 538 | 2.38 / 134.11 | 6 | 16 |
4 | 13 | 608.52 | 20 | 14.61 | 1157 | 338 | 2.72 / 134.45 | 6 | 19 |
5 | 13 | 142.60 | 20 | 14.76 | 575 | 170 | 2.89 / 134.62 | 6 | 19 |
6 | 8 | 0.00 | 321 | 14.73 | 380 | 1797 | 4.69 / 136.41 | 6 | 153 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 27 | 14.72 | 501 | 199 | 0.20 / 127.27 | 6 | 7 |
2 | 7 | 2001.80 | 40 | 14.29 | 2853 | 1631 | 1.83 / 128.90 | 7 | 12 |
3 | 13 | 1185.36 | 20 | 14.46 | 1872 | 541 | 2.37 / 129.44 | 6 | 16 |
4 | 13 | 623.40 | 20 | 14.60 | 1184 | 346 | 2.72 / 129.79 | 6 | 22 |
5 | 13 | 162.84 | 20 | 14.75 | 605 | 178 | 2.90 / 129.97 | 6 | 19 |
6 | 8 | 0.00 | 319 | 14.73 | 374 | 1757 | 4.65 / 131.73 | 6 | 135 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 27 | 14.72 | 501 | 199 | 0.20 / 122.62 | 6 | 7 |
2 | 7 | 2002.32 | 40 | 14.28 | 2867 | 1638 | 1.84 / 124.26 | 7 | 10 |
3 | 13 | 1159.76 | 20 | 14.47 | 1845 | 534 | 2.37 / 124.79 | 6 | 16 |
4 | 13 | 590.48 | 20 | 14.62 | 1130 | 330 | 2.70 / 125.12 | 6 | 16 |
5 | 13 | 135.20 | 20 | 14.77 | 564 | 167 | 2.87 / 125.29 | 6 | 23 |
6 | 8 | -0.08 | 319 | 14.74 | 380 | 1787 | 4.65 / 127.07 | 6 | 153 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 27 | 14.73 | 501 | 199 | 0.20 / 117.89 | 6 | 6 |
2 | 7 | 2001.60 | 40 | 14.29 | 2858 | 1634 | 1.83 / 119.53 | 6 | 10 |
3 | 13 | 1161.96 | 20 | 14.48 | 1843 | 534 | 2.37 / 120.06 | 6 | 15 |
4 | 13 | 699.32 | 20 | 14.58 | 1277 | 372 | 2.74 / 120.43 | 6 | 22 |
5 | 13 | 205.96 | 20 | 14.74 | 660 | 195 | 2.93 / 120.63 | 6 | 21 |
6 | 8 | -0.04 | 321 | 14.74 | 379 | 1793 | 4.73 / 122.42 | 6 | 138 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 27 | 14.74 | 506 | 201 | 0.20 / 113.20 | 6 | 7 |
2 | 7 | 2002.04 | 40 | 14.30 | 2856 | 1634 | 1.84 / 114.84 | 7 | 14 |
3 | 13 | 1267.08 | 20 | 14.45 | 1980 | 572 | 2.41 / 115.41 | 6 | 17 |
4 | 13 | 581.56 | 20 | 14.63 | 1121 | 328 | 2.74 / 115.74 | 6 | 20 |
5 | 13 | 134.28 | 20 | 14.78 | 560 | 166 | 2.90 / 115.90 | 6 | 17 |
6 | 8 | 0.08 | 319 | 14.75 | 380 | 1788 | 4.69 / 117.69 | 6 | 140 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 27 | 14.75 | 494 | 197 | 0.20 / 108.50 | 6 | 7 |
2 | 7 | 2003.68 | 41 | 14.29 | 2857 | 1674 | 1.87 / 110.17 | 7 | 14 |
3 | 13 | 1166.24 | 20 | 14.48 | 1857 | 538 | 2.41 / 110.71 | 6 | 16 |
4 | 13 | 601.60 | 20 | 14.62 | 1144 | 335 | 2.74 / 111.05 | 6 | 25 |
5 | 13 | 143.24 | 20 | 14.78 | 575 | 170 | 2.91 / 111.22 | 6 | 21 |
6 | 8 | -0.08 | 319 | 14.75 | 380 | 1788 | 4.70 / 113.00 | 6 | 151 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 27 | 14.74 | 502 | 200 | 0.20 / 103.86 | 6 | 7 |
2 | 7 | 2002.64 | 40 | 14.31 | 2848 | 1630 | 1.83 / 105.49 | 7 | 10 |
3 | 13 | 1180.64 | 20 | 14.48 | 1872 | 542 | 2.37 / 106.03 | 6 | 18 |
4 | 13 | 617.52 | 20 | 14.63 | 1169 | 342 | 2.71 / 106.37 | 6 | 19 |
5 | 13 | 150.36 | 20 | 14.78 | 586 | 173 | 2.89 / 106.54 | 6 | 19 |
6 | 8 | 0.00 | 319 | 14.75 | 374 | 1760 | 4.65 / 108.30 | 6 | 130 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 27 | 14.75 | 499 | 199 | 0.20 / 99.15 | 6 | 7 |
2 | 7 | 2002.92 | 40 | 14.31 | 2848 | 1630 | 1.83 / 100.78 | 7 | 11 |
3 | 13 | 1264.68 | 20 | 14.46 | 1972 | 570 | 2.40 / 101.35 | 6 | 17 |
4 | 13 | 659.64 | 20 | 14.61 | 1219 | 356 | 2.76 / 101.71 | 6 | 18 |
5 | 13 | 185.04 | 20 | 14.77 | 634 | 187 | 2.94 / 101.89 | 6 | 21 |
6 | 8 | -0.04 | 319 | 14.76 | 374 | 1761 | 4.70 / 103.66 | 6 | 141 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 27 | 14.75 | 500 | 199 | 0.20 / 94.50 | 6 | 6 |
2 | 7 | 2001.20 | 40 | 14.31 | 2841 | 1626 | 1.83 / 96.13 | 6 | 10 |
3 | 13 | 1259.12 | 20 | 14.47 | 1955 | 566 | 2.39 / 96.69 | 6 | 15 |
4 | 13 | 568.60 | 20 | 14.65 | 1101 | 323 | 2.71 / 97.01 | 6 | 21 |
5 | 13 | 123.04 | 20 | 14.80 | 546 | 162 | 2.88 / 97.18 | 6 | 16 |
6 | 8 | 0.08 | 319 | 14.77 | 377 | 1776 | 4.65 / 98.95 | 6 | 132 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 27 | 14.76 | 490 | 195 | 0.20 / 89.88 | 6 | 7 |
2 | 7 | 2004.60 | 40 | 14.32 | 2846 | 1630 | 1.83 / 91.51 | 7 | 11 |
3 | 13 | 1177.24 | 20 | 14.50 | 1860 | 539 | 2.36 / 92.05 | 6 | 16 |
4 | 13 | 601.48 | 20 | 14.64 | 1144 | 335 | 2.70 / 92.38 | 6 | 18 |
5 | 13 | 133.64 | 20 | 14.80 | 558 | 165 | 2.86 / 92.55 | 6 | 17 |
6 | 8 | -0.04 | 319 | 14.77 | 372 | 1753 | 4.62 / 94.30 | 6 | 143 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 27 | 14.76 | 497 | 198 | 0.20 / 85.23 | 6 | 6 |
2 | 7 | 2000.52 | 40 | 14.32 | 2849 | 1632 | 1.83 / 86.86 | 6 | 10 |
3 | 13 | 1269.00 | 20 | 14.48 | 1966 | 569 | 2.40 / 87.43 | 6 | 15 |
4 | 13 | 587.24 | 20 | 14.66 | 1121 | 329 | 2.73 / 87.76 | 6 | 22 |
5 | 13 | 141.36 | 20 | 14.80 | 568 | 168 | 2.90 / 87.93 | 6 | 18 |
6 | 8 | -0.04 | 321 | 14.78 | 370 | 1755 | 4.65 / 89.68 | 6 | 137 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 27 | 14.77 | 494 | 197 | 0.20 / 80.58 | 6 | 7 |
2 | 7 | 2001.48 | 40 | 14.32 | 2828 | 1620 | 1.82 / 82.20 | 7 | 12 |
3 | 13 | 1280.12 | 20 | 14.48 | 1959 | 567 | 2.38 / 82.77 | 6 | 16 |
4 | 13 | 586.48 | 20 | 14.66 | 1094 | 321 | 2.70 / 83.09 | 6 | 24 |
5 | 13 | 135.48 | 20 | 14.81 | 559 | 166 | 2.87 / 83.26 | 6 | 16 |
6 | 8 | 0.08 | 323 | 14.78 | 372 | 1776 | 4.65 / 85.03 | 6 | 135 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 27 | 14.77 | 496 | 198 | 0.20 / 75.96 | 6 | 6 |
2 | 7 | 2002.28 | 40 | 14.32 | 2840 | 1627 | 1.82 / 77.58 | 6 | 12 |
3 | 13 | 1198.52 | 20 | 14.50 | 1894 | 549 | 2.37 / 78.13 | 6 | 17 |
4 | 13 | 614.56 | 20 | 14.65 | 1151 | 337 | 2.71 / 78.47 | 6 | 21 |
5 | 13 | 146.68 | 20 | 14.81 | 567 | 168 | 2.88 / 78.64 | 6 | 17 |
6 | 8 | -0.04 | 323 | 14.78 | 366 | 1747 | 4.63 / 80.38 | 6 | 139 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 27 | 14.78 | 485 | 194 | 0.19 / 71.37 | 6 | 7 |
2 | 7 | 2002.48 | 40 | 14.32 | 2844 | 1629 | 1.82 / 73.00 | 7 | 11 |
3 | 13 | 1169.80 | 20 | 14.51 | 1856 | 539 | 2.36 / 73.54 | 6 | 17 |
4 | 13 | 599.32 | 20 | 14.66 | 1143 | 335 | 2.70 / 73.88 | 6 | 17 |
5 | 13 | 136.40 | 20 | 14.82 | 554 | 164 | 2.86 / 74.04 | 6 | 19 |
6 | 8 | -0.04 | 321 | 14.79 | 362 | 1719 | 4.58 / 75.76 | 6 | 142 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 27 | 14.79 | 480 | 192 | 0.19 / 66.74 | 6 | 6 |
2 | 7 | 2002.04 | 40 | 14.34 | 2838 | 1628 | 1.82 / 68.37 | 6 | 15 |
3 | 13 | 1181.64 | 20 | 14.52 | 1855 | 539 | 2.36 / 68.91 | 6 | 16 |
4 | 13 | 709.80 | 20 | 14.63 | 1288 | 377 | 2.74 / 69.28 | 6 | 23 |
5 | 13 | 130.52 | 20 | 14.83 | 546 | 162 | 2.90 / 69.44 | 6 | 18 |
6 | 8 | 0.00 | 323 | 14.80 | 363 | 1735 | 4.63 / 71.18 | 6 | 133 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 27 | 14.79 | 486 | 194 | 0.19 / 62.06 | 6 | 6 |
2 | 7 | 2005.76 | 40 | 14.34 | 2829 | 1623 | 1.82 / 63.69 | 6 | 12 |
3 | 13 | 1183.76 | 20 | 14.52 | 1857 | 539 | 2.36 / 64.22 | 6 | 16 |
4 | 13 | 709.08 | 20 | 14.63 | 1272 | 372 | 2.73 / 64.60 | 6 | 18 |
5 | 13 | 203.20 | 20 | 14.79 | 644 | 190 | 2.92 / 64.79 | 6 | 22 |
6 | 8 | 0.08 | 323 | 14.80 | 368 | 1759 | 4.68 / 66.55 | 6 | 136 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 27 | 14.79 | 481 | 192 | 0.19 / 57.46 | 6 | 6 |
2 | 7 | 2001.12 | 40 | 14.34 | 2841 | 1630 | 1.82 / 59.09 | 6 | 12 |
3 | 13 | 1186.68 | 20 | 14.53 | 1854 | 539 | 2.36 / 59.63 | 6 | 15 |
4 | 13 | 624.40 | 20 | 14.67 | 1167 | 342 | 2.70 / 59.97 | 6 | 20 |
5 | 13 | 150.20 | 20 | 14.82 | 574 | 170 | 2.87 / 60.14 | 6 | 17 |
6 | 8 | -0.04 | 323 | 14.80 | 362 | 1731 | 4.60 / 61.87 | 6 | 139 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 27 | 14.81 | 470 | 188 | 0.19 / 52.84 | 6 | 6 |
2 | 7 | 2000.76 | 40 | 14.35 | 2836 | 1628 | 1.82 / 54.47 | 6 | 13 |
3 | 13 | 1248.92 | 20 | 14.51 | 1943 | 564 | 2.38 / 55.03 | 6 | 16 |
4 | 13 | 645.32 | 20 | 14.67 | 1181 | 347 | 2.73 / 55.38 | 6 | 18 |
5 | 13 | 162.64 | 20 | 14.83 | 582 | 173 | 2.90 / 55.55 | 6 | 18 |
6 | 8 | 0.04 | 323 | 14.81 | 358 | 1713 | 4.61 / 57.27 | 6 | 132 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 27 | 14.81 | 477 | 191 | 0.19 / 48.30 | 6 | 7 |
2 | 7 | 2000.28 | 41 | 14.35 | 2838 | 1670 | 1.86 / 49.97 | 7 | 13 |
3 | 13 | 1244.20 | 20 | 14.51 | 1926 | 559 | 2.42 / 50.53 | 6 | 16 |
4 | 13 | 543.68 | 20 | 14.71 | 1057 | 311 | 2.73 / 50.84 | 6 | 22 |
5 | 13 | 105.00 | 20 | 14.86 | 499 | 148 | 2.88 / 50.98 | 6 | 17 |
6 | 8 | -0.16 | 321 | 14.82 | 351 | 1670 | 4.55 / 52.65 | 6 | 131 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 27 | 14.80 | 470 | 188 | 0.19 / 43.77 | 6 | 6 |
2 | 7 | 2002.00 | 40 | 14.35 | 2826 | 1622 | 1.81 / 45.40 | 6 | 13 |
3 | 13 | 1164.16 | 20 | 14.55 | 1829 | 532 | 2.34 / 45.93 | 6 | 18 |
4 | 13 | 597.56 | 20 | 14.69 | 1122 | 330 | 2.67 / 46.26 | 6 | 18 |
5 | 13 | 130.60 | 20 | 14.85 | 533 | 158 | 2.83 / 46.42 | 6 | 18 |
6 | 8 | 0.04 | 323 | 14.82 | 353 | 1690 | 4.52 / 48.11 | 6 | 138 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 27 | 14.81 | 469 | 188 | 0.19 / 39.17 | 6 | 6 |
2 | 7 | 2000.52 | 40 | 14.38 | 2815 | 1619 | 1.81 / 40.79 | 6 | 12 |
3 | 13 | 1261.64 | 20 | 14.53 | 1949 | 566 | 2.37 / 41.36 | 6 | 16 |
4 | 13 | 672.68 | 20 | 14.67 | 1215 | 356 | 2.73 / 41.72 | 6 | 19 |
5 | 13 | 182.20 | 20 | 14.83 | 601 | 178 | 2.91 / 41.90 | 6 | 20 |
6 | 8 | -0.20 | 325 | 14.82 | 351 | 1691 | 4.60 / 43.59 | 6 | 144 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 26 | 14.81 | 468 | 180 | 0.18 / 34.57 | 6 | 6 |
2 | 7 | 1996.12 | 41 | 14.36 | 2818 | 1659 | 1.84 / 36.23 | 6 | 11 |
3 | 13 | 1245.80 | 20 | 14.54 | 1918 | 558 | 2.40 / 36.78 | 6 | 16 |
4 | 13 | 659.48 | 20 | 14.68 | 1196 | 351 | 2.75 / 37.14 | 6 | 20 |
5 | 13 | 160.72 | 20 | 14.84 | 572 | 170 | 2.92 / 37.31 | 6 | 18 |
6 | 8 | 0.00 | 325 | 14.83 | 349 | 1682 | 4.60 / 38.99 | 6 | 143 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 26 | 14.81 | 478 | 184 | 0.18 / 30.07 | 6 | 6 |
2 | 7 | 1995.56 | 40 | 14.37 | 2817 | 1619 | 1.80 / 31.69 | 6 | 11 |
3 | 13 | 1247.88 | 20 | 14.53 | 1935 | 562 | 2.37 / 32.25 | 6 | 16 |
4 | 13 | 552.96 | 20 | 14.72 | 1063 | 313 | 2.68 / 32.56 | 6 | 19 |
5 | 13 | 106.92 | 20 | 14.87 | 503 | 150 | 2.83 / 32.71 | 6 | 16 |
6 | 8 | -0.08 | 323 | 14.83 | 350 | 1677 | 4.50 / 34.39 | 6 | 139 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 26 | 14.82 | 456 | 176 | 0.18 / 25.49 | 6 | 6 |
2 | 7 | 1991.96 | 40 | 14.38 | 2813 | 1618 | 1.79 / 27.11 | 6 | 11 |
3 | 13 | 1248.08 | 20 | 14.54 | 1922 | 559 | 2.35 / 27.67 | 6 | 16 |
4 | 13 | 661.76 | 20 | 14.68 | 1196 | 351 | 2.70 / 28.02 | 6 | 20 |
5 | 13 | 175.32 | 20 | 14.84 | 589 | 175 | 2.88 / 28.19 | 6 | 20 |
6 | 8 | -0.08 | 327 | 14.83 | 348 | 1688 | 4.57 / 29.88 | 6 | 141 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 26 | 14.83 | 455 | 175 | 0.18 / 20.97 | 6 | 6 |
2 | 3 | 1024.04 | 1 | 14.81 | 1608 | 24 | 0.20 / 20.99 | 6 | 11 |
3 | 7 | 1988.52 | 40 | 14.39 | 2782 | 1601 | 1.80 / 22.60 | 11 | 11 |
4 | 13 | 1162.44 | 20 | 14.57 | 1797 | 524 | 2.32 / 23.12 | 6 | 16 |
5 | 13 | 688.92 | 20 | 14.68 | 1207 | 354 | 2.68 / 23.47 | 6 | 18 |
6 | 13 | 190.80 | 20 | 14.84 | 605 | 180 | 2.86 / 23.65 | 6 | 18 |
7 | 8 | -0.08 | 325 | 14.83 | 345 | 1663 | 4.52 / 25.32 | 6 | 140 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 31 | 14.83 | 444 | 204 | 0.20 / 16.60 | 6 | 6 |
2 | 3 | 823.36 | -3 | 15.28 | 12 | 0 | 0.00 / 16.60 | 6 | 6 |
3 | 7 | 1987.12 | 40 | 14.40 | 2761 | 1590 | 1.79 / 18.19 | 6 | 13 |
4 | 13 | 1142.56 | 20 | 14.58 | 1775 | 518 | 2.31 / 18.71 | 6 | 15 |
5 | 13 | 571.80 | 20 | 14.73 | 1074 | 316 | 2.63 / 19.03 | 6 | 20 |
6 | 13 | 103.32 | 20 | 14.88 | 486 | 145 | 2.77 / 19.17 | 6 | 15 |
7 | 8 | -0.04 | 326 | 14.85 | 335 | 1622 | 4.39 / 20.80 | 6 | 158 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 26 | 14.84 | 459 | 177 | 0.18 / 12.70 | 6 | 6 |
2 | 7 | 1518.28 | 40 | 14.57 | 2230 | 1300 | 1.48 / 14.00 | 6 | 14 |
3 | 13 | 985.76 | 20 | 14.67 | 1583 | 464 | 1.94 / 14.47 | 6 | 18 |
4 | 13 | 428.68 | 20 | 14.80 | 893 | 264 | 2.21 / 14.73 | 6 | 22 |
5 | 8 | 0.00 | 338 | 14.87 | 332 | 1669 | 3.87 / 16.40 | 6 | 129 |
Average= | 3.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 25 | 14.84 | 450 | 167 | 0.17 / 8.75 | 6 | 7 |
2 | 7 | 1517.64 | 40 | 14.58 | 2215 | 1292 | 1.46 / 10.04 | 7 | 12 |
3 | 13 | 1079.00 | 20 | 14.65 | 1696 | 497 | 1.96 / 10.54 | 6 | 17 |
4 | 13 | 509.24 | 20 | 14.78 | 990 | 293 | 2.25 / 10.83 | 6 | 16 |
5 | 13 | 71.72 | 20 | 14.92 | 436 | 130 | 2.38 / 10.96 | 6 | 19 |
6 | 8 | -0.08 | 319 | 14.87 | 330 | 1565 | 3.94 / 12.53 | 6 | 135 |
Average= | 3.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.76 | 31 | 14.87 | 457 | 211 | 0.21 / 4.85 | 6 | 6 |
2 | 3 | 806.84 | -3 | 15.30 | 12 | 0 | 0.00 / 4.85 | 6 | 6 |
3 | 7 | 1513.84 | 40 | 14.59 | 2208 | 1289 | 1.50 / 6.14 | 6 | 13 |
4 | 13 | 1084.36 | 20 | 14.65 | 1707 | 500 | 2.00 / 6.64 | 6 | 16 |
5 | 13 | 394.84 | 20 | 14.81 | 847 | 251 | 2.25 / 6.89 | 6 | 18 |
6 | 13 | 37.96 | 20 | 14.93 | 385 | 115 | 2.37 / 7.01 | 6 | 19 |
7 | 8 | 0.04 | 321 | 14.87 | 330 | 1575 | 3.94 / 8.58 | 6 | 134 |
Average= | 2.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 31 | 15.01 | 415 | 193 | 0.19 / 2.02 | 6 | 6 |
2 | 3 | 802.76 | -3 | 15.31 | 12 | 0 | 0.00 / 2.02 | 6 | 6 |
3 | 7 | 926.00 | 41 | 14.76 | 1498 | 907 | 1.10 / 2.93 | 6 | 14 |
4 | 13 | 137.96 | 20 | 14.96 | 510 | 153 | 1.25 / 3.08 | 6 | 14 |
5 | 8 | 0.00 | 325 | 14.93 | 322 | 1562 | 2.81 / 4.64 | 6 | 133 |
Average= | 2.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 79.00 | 30 | 15.23 | 384 | 175 | 0.18 / 0.18 | 6 | 7 |
2 | 7 | 92.84 | 40 | 15.21 | 394 | 240 | 0.42 / 0.42 | 7 | 7 |
3 | 8 | 0.36 | 344 | 15.15 | 271 | 1412 | 1.83 / 1.83 | 6 | 140 |
Average= | 1.83 (KJ/cycle) |