SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 37 | 14.95 | 499 | 276 | 0.28 / 737.50 | 5 | 9 |
2 | 7 | 2013.12 | 40 | 14.65 | 3551 | 2081 | 2.36 / 739.58 | 9 | 28 |
3 | 13 | 1934.00 | 20 | 14.62 | 3430 | 1003 | 3.36 / 740.58 | 4 | 31 |
4 | 13 | 1401.48 | 20 | 14.65 | 2638 | 773 | 4.13 / 741.36 | 4 | 39 |
5 | 13 | 962.92 | 20 | 14.73 | 1957 | 577 | 4.71 / 741.93 | 4 | 43 |
6 | 13 | 292.64 | 20 | 14.93 | 878 | 262 | 4.97 / 742.20 | 5 | 44 |
7 | 13 | 19.96 | 20 | 15.02 | 380 | 114 | 5.09 / 742.31 | 5 | 14 |
8 | 8 | -0.04 | 400 | 14.94 | 338 | 2020 | 7.11 / 744.33 | 5 | 36 |
Average= | 7.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 37 | 14.94 | 526 | 291 | 0.29 / 730.44 | 5 | 9 |
2 | 7 | 2009.36 | 40 | 14.65 | 3535 | 2072 | 2.36 / 732.51 | 9 | 29 |
3 | 13 | 1918.92 | 20 | 14.62 | 3416 | 999 | 3.36 / 733.51 | 4 | 32 |
4 | 13 | 1494.44 | 20 | 14.63 | 2779 | 813 | 4.17 / 734.32 | 4 | 38 |
5 | 13 | 817.04 | 20 | 14.78 | 1732 | 512 | 4.69 / 734.84 | 4 | 44 |
6 | 13 | 177.84 | 20 | 14.98 | 676 | 203 | 4.89 / 735.04 | 5 | 39 |
7 | 13 | 18.84 | 20 | 15.02 | 374 | 112 | 5.00 / 735.15 | 5 | 13 |
8 | 8 | -0.08 | 400 | 14.94 | 347 | 2074 | 7.07 / 737.22 | 5 | 38 |
Average= | 7.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 37 | 14.95 | 523 | 289 | 0.29 / 723.32 | 5 | 11 |
2 | 7 | 2005.16 | 40 | 14.66 | 3531 | 2071 | 2.36 / 725.39 | 11 | 29 |
3 | 13 | 1918.68 | 20 | 14.63 | 3413 | 999 | 3.36 / 726.39 | 4 | 32 |
4 | 13 | 1603.96 | 20 | 14.61 | 2948 | 861 | 4.22 / 727.25 | 4 | 37 |
5 | 13 | 948.40 | 20 | 14.74 | 1944 | 573 | 4.79 / 727.82 | 4 | 43 |
6 | 13 | 276.32 | 20 | 14.94 | 848 | 253 | 5.05 / 728.07 | 5 | 43 |
7 | 8 | -0.08 | 400 | 14.95 | 347 | 2075 | 7.12 / 730.15 | 5 | 36 |
Average= | 7.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 37 | 14.96 | 502 | 278 | 0.28 / 716.30 | 5 | 10 |
2 | 7 | 2004.56 | 40 | 14.66 | 3527 | 2068 | 2.35 / 718.37 | 10 | 29 |
3 | 13 | 1912.08 | 20 | 14.63 | 3399 | 995 | 3.34 / 719.36 | 4 | 32 |
4 | 13 | 1599.40 | 20 | 14.61 | 2933 | 857 | 4.20 / 720.22 | 4 | 37 |
5 | 13 | 730.56 | 20 | 14.81 | 1598 | 473 | 4.67 / 720.69 | 4 | 44 |
6 | 13 | 296.40 | 20 | 14.93 | 886 | 265 | 4.94 / 720.96 | 5 | 44 |
7 | 8 | -0.04 | 400 | 14.95 | 346 | 2069 | 7.00 / 723.03 | 5 | 37 |
Average= | 7.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 37 | 14.96 | 490 | 271 | 0.27 / 709.36 | 5 | 9 |
2 | 7 | 2006.20 | 40 | 14.66 | 3540 | 2076 | 2.35 / 711.44 | 9 | 28 |
3 | 13 | 1921.56 | 20 | 14.63 | 3408 | 997 | 3.34 / 712.44 | 4 | 32 |
4 | 13 | 1494.80 | 20 | 14.64 | 2778 | 813 | 4.16 / 713.25 | 4 | 38 |
5 | 13 | 844.32 | 20 | 14.77 | 1773 | 524 | 4.68 / 713.77 | 4 | 43 |
6 | 13 | 292.96 | 20 | 14.94 | 878 | 262 | 4.94 / 714.04 | 5 | 44 |
7 | 8 | -0.12 | 400 | 14.96 | 332 | 1987 | 6.93 / 716.02 | 5 | 39 |
Average= | 7.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 37 | 14.95 | 515 | 285 | 0.28 / 702.47 | 5 | 11 |
2 | 7 | 2004.52 | 40 | 14.67 | 3521 | 2066 | 2.35 / 704.54 | 11 | 28 |
3 | 13 | 1921.48 | 20 | 14.64 | 3408 | 998 | 3.35 / 705.54 | 4 | 32 |
4 | 13 | 1411.04 | 20 | 14.66 | 2653 | 778 | 4.13 / 706.31 | 5 | 38 |
5 | 13 | 778.16 | 20 | 14.80 | 1675 | 496 | 4.62 / 706.81 | 5 | 43 |
6 | 13 | 363.24 | 20 | 14.92 | 998 | 298 | 4.92 / 707.11 | 5 | 44 |
7 | 8 | -0.08 | 400 | 14.96 | 332 | 1987 | 6.91 / 709.09 | 5 | 40 |
Average= | 7.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 37 | 14.94 | 530 | 293 | 0.29 / 695.46 | 5 | 10 |
2 | 7 | 2003.64 | 40 | 14.66 | 3530 | 2070 | 2.36 / 697.53 | 10 | 29 |
3 | 13 | 1905.64 | 20 | 14.63 | 3391 | 992 | 3.36 / 698.52 | 4 | 32 |
4 | 13 | 1488.12 | 20 | 14.64 | 2779 | 814 | 4.17 / 699.34 | 4 | 38 |
5 | 13 | 926.84 | 20 | 14.75 | 1905 | 562 | 4.73 / 699.90 | 4 | 43 |
6 | 13 | 359.80 | 20 | 14.92 | 994 | 297 | 5.03 / 700.19 | 5 | 44 |
7 | 8 | 0.00 | 400 | 14.96 | 333 | 1993 | 7.02 / 702.19 | 5 | 39 |
Average= | 7.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 37 | 14.95 | 541 | 299 | 0.30 / 688.26 | 5 | 10 |
2 | 7 | 2009.12 | 40 | 14.66 | 3541 | 2076 | 2.38 / 690.33 | 10 | 29 |
3 | 13 | 1919.96 | 20 | 14.63 | 3402 | 995 | 3.37 / 691.33 | 4 | 32 |
4 | 13 | 1499.76 | 20 | 14.64 | 2780 | 814 | 4.19 / 692.14 | 4 | 37 |
5 | 13 | 1061.00 | 20 | 14.71 | 2118 | 623 | 4.81 / 692.77 | 4 | 43 |
6 | 13 | 287.68 | 20 | 14.95 | 865 | 259 | 5.07 / 693.03 | 5 | 43 |
7 | 8 | 0.00 | 400 | 14.95 | 358 | 2141 | 7.21 / 695.17 | 5 | 38 |
Average= | 7.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 37 | 14.95 | 547 | 303 | 0.30 / 681.20 | 5 | 9 |
2 | 7 | 2005.44 | 40 | 14.67 | 3531 | 2072 | 2.37 / 683.27 | 9 | 29 |
3 | 13 | 1909.08 | 20 | 14.65 | 3394 | 994 | 3.37 / 684.27 | 4 | 32 |
4 | 13 | 1592.64 | 20 | 14.62 | 2941 | 860 | 4.23 / 685.13 | 4 | 37 |
5 | 13 | 836.88 | 20 | 14.78 | 1768 | 523 | 4.75 / 685.65 | 4 | 44 |
6 | 13 | 290.72 | 20 | 14.94 | 877 | 262 | 5.01 / 685.91 | 5 | 43 |
7 | 8 | -0.08 | 400 | 14.96 | 342 | 2047 | 7.06 / 687.96 | 5 | 44 |
Average= | 7.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 37 | 14.95 | 535 | 296 | 0.30 / 674.14 | 5 | 11 |
2 | 7 | 2006.20 | 40 | 14.67 | 3530 | 2071 | 2.37 / 676.21 | 11 | 29 |
3 | 13 | 1919.88 | 20 | 14.63 | 3426 | 1002 | 3.37 / 677.21 | 4 | 32 |
4 | 13 | 1386.92 | 20 | 14.66 | 2621 | 768 | 4.14 / 677.98 | 4 | 39 |
5 | 13 | 839.88 | 20 | 14.78 | 1772 | 524 | 4.66 / 678.51 | 4 | 44 |
6 | 13 | 279.40 | 20 | 14.95 | 859 | 257 | 4.92 / 678.76 | 5 | 44 |
7 | 8 | -0.08 | 400 | 14.96 | 357 | 2136 | 7.06 / 680.90 | 5 | 43 |
Average= | 7.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 37 | 14.96 | 518 | 287 | 0.29 / 667.17 | 5 | 12 |
2 | 7 | 2010.48 | 40 | 14.66 | 3535 | 2073 | 2.36 / 669.24 | 12 | 29 |
3 | 13 | 1919.28 | 20 | 14.64 | 3408 | 998 | 3.36 / 670.24 | 4 | 32 |
4 | 13 | 1487.36 | 20 | 14.64 | 2769 | 811 | 4.17 / 671.05 | 4 | 39 |
5 | 13 | 736.00 | 20 | 14.82 | 1605 | 476 | 4.64 / 671.52 | 4 | 43 |
6 | 13 | 210.36 | 20 | 14.98 | 728 | 218 | 4.86 / 671.74 | 5 | 43 |
7 | 13 | 22.16 | 20 | 15.04 | 379 | 114 | 4.98 / 671.86 | 5 | 15 |
8 | 8 | -0.04 | 400 | 14.96 | 332 | 1987 | 6.96 / 673.84 | 5 | 43 |
Average= | 7.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 37 | 14.96 | 536 | 297 | 0.30 / 660.26 | 5 | 12 |
2 | 7 | 2004.60 | 40 | 14.67 | 3533 | 2073 | 2.37 / 662.34 | 12 | 28 |
3 | 13 | 1921.84 | 20 | 14.64 | 3413 | 999 | 3.37 / 663.34 | 4 | 32 |
4 | 13 | 1512.88 | 20 | 14.64 | 2803 | 821 | 4.19 / 664.16 | 4 | 38 |
5 | 13 | 773.76 | 20 | 14.81 | 1666 | 493 | 4.68 / 664.65 | 4 | 44 |
6 | 13 | 248.76 | 20 | 14.96 | 806 | 241 | 4.92 / 664.89 | 5 | 43 |
7 | 8 | 0.00 | 400 | 14.97 | 332 | 1988 | 6.91 / 666.88 | 5 | 40 |
Average= | 7.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 37 | 14.96 | 536 | 297 | 0.30 / 653.34 | 5 | 9 |
2 | 7 | 2011.72 | 40 | 14.67 | 3540 | 2077 | 2.37 / 655.42 | 9 | 29 |
3 | 13 | 1931.32 | 20 | 14.64 | 3413 | 999 | 3.37 / 656.42 | 4 | 31 |
4 | 13 | 1311.92 | 20 | 14.69 | 2507 | 737 | 4.11 / 657.16 | 4 | 40 |
5 | 13 | 803.52 | 20 | 14.80 | 1703 | 504 | 4.61 / 657.66 | 4 | 44 |
6 | 13 | 272.56 | 20 | 14.96 | 845 | 253 | 4.87 / 657.91 | 5 | 43 |
7 | 8 | 0.00 | 400 | 14.97 | 343 | 2054 | 6.92 / 659.97 | 5 | 39 |
Average= | 7.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 37 | 14.96 | 547 | 303 | 0.30 / 646.09 | 5 | 11 |
2 | 7 | 2013.96 | 40 | 14.66 | 3555 | 2085 | 2.39 / 648.17 | 11 | 29 |
3 | 13 | 1930.80 | 20 | 14.63 | 3421 | 1001 | 3.39 / 649.17 | 4 | 32 |
4 | 13 | 1610.32 | 20 | 14.62 | 2942 | 860 | 4.25 / 650.03 | 4 | 37 |
5 | 13 | 1145.52 | 20 | 14.69 | 2248 | 660 | 4.91 / 650.69 | 4 | 42 |
6 | 13 | 321.12 | 20 | 14.94 | 928 | 277 | 5.19 / 650.97 | 5 | 45 |
7 | 8 | -0.08 | 400 | 14.97 | 347 | 2078 | 7.26 / 653.05 | 5 | 46 |
Average= | 7.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 37 | 14.97 | 538 | 298 | 0.30 / 638.98 | 5 | 10 |
2 | 7 | 2007.08 | 40 | 14.67 | 3535 | 2074 | 2.37 / 641.06 | 10 | 29 |
3 | 13 | 1923.44 | 20 | 14.64 | 3417 | 1000 | 3.37 / 642.06 | 4 | 32 |
4 | 13 | 1500.48 | 20 | 14.64 | 2786 | 816 | 4.19 / 642.87 | 4 | 38 |
5 | 13 | 849.48 | 20 | 14.79 | 1784 | 528 | 4.72 / 643.40 | 4 | 44 |
6 | 13 | 292.40 | 20 | 14.95 | 883 | 264 | 4.98 / 643.66 | 5 | 44 |
7 | 8 | 0.04 | 400 | 14.97 | 354 | 2120 | 7.10 / 645.78 | 5 | 34 |
Average= | 7.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 37 | 14.96 | 546 | 302 | 0.30 / 631.94 | 5 | 10 |
2 | 7 | 2012.16 | 40 | 14.68 | 3539 | 2078 | 2.38 / 634.02 | 10 | 28 |
3 | 13 | 1825.84 | 20 | 14.65 | 3264 | 956 | 3.34 / 634.98 | 4 | 33 |
4 | 13 | 1520.48 | 20 | 14.64 | 2820 | 826 | 4.16 / 635.80 | 4 | 38 |
5 | 13 | 968.92 | 20 | 14.75 | 1973 | 582 | 4.74 / 636.38 | 4 | 43 |
6 | 13 | 210.64 | 20 | 14.99 | 734 | 220 | 4.96 / 636.60 | 5 | 42 |
7 | 8 | 0.00 | 400 | 14.98 | 347 | 2079 | 7.04 / 638.68 | 5 | 45 |
Average= | 7.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 37 | 14.97 | 528 | 292 | 0.29 / 624.91 | 5 | 10 |
2 | 7 | 2008.16 | 40 | 14.67 | 3537 | 2076 | 2.37 / 626.99 | 10 | 29 |
3 | 13 | 1919.20 | 20 | 14.64 | 3409 | 998 | 3.37 / 627.99 | 4 | 32 |
4 | 13 | 1318.64 | 20 | 14.69 | 2515 | 739 | 4.11 / 628.72 | 4 | 39 |
5 | 13 | 892.80 | 20 | 14.77 | 1861 | 550 | 4.65 / 629.27 | 5 | 43 |
6 | 13 | 318.08 | 20 | 14.94 | 923 | 276 | 4.93 / 629.55 | 5 | 44 |
7 | 8 | 0.00 | 400 | 14.97 | 349 | 2090 | 7.02 / 631.64 | 5 | 37 |
Average= | 7.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 37 | 14.96 | 547 | 303 | 0.30 / 618.00 | 5 | 10 |
2 | 7 | 2009.16 | 40 | 14.67 | 3533 | 2073 | 2.38 / 620.08 | 10 | 28 |
3 | 13 | 1925.48 | 20 | 14.64 | 3421 | 1002 | 3.38 / 621.08 | 4 | 32 |
4 | 13 | 1421.64 | 20 | 14.67 | 2664 | 782 | 4.16 / 621.86 | 4 | 38 |
5 | 13 | 893.76 | 20 | 14.78 | 1848 | 546 | 4.71 / 622.41 | 5 | 43 |
6 | 13 | 241.04 | 20 | 14.98 | 788 | 236 | 4.94 / 622.64 | 5 | 43 |
7 | 8 | 0.00 | 400 | 14.98 | 330 | 1977 | 6.92 / 624.62 | 5 | 43 |
Average= | 7.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 37 | 14.97 | 524 | 290 | 0.29 / 610.87 | 5 | 10 |
2 | 7 | 2007.36 | 40 | 14.68 | 3534 | 2075 | 2.37 / 612.95 | 10 | 28 |
3 | 13 | 1920.28 | 20 | 14.65 | 3403 | 997 | 3.36 / 613.95 | 4 | 32 |
4 | 13 | 1485.96 | 20 | 14.66 | 2760 | 809 | 4.17 / 614.76 | 4 | 37 |
5 | 13 | 837.88 | 20 | 14.80 | 1765 | 522 | 4.69 / 615.28 | 4 | 43 |
6 | 13 | 290.48 | 20 | 14.96 | 871 | 261 | 4.95 / 615.54 | 5 | 44 |
7 | 8 | 0.00 | 400 | 14.97 | 361 | 2162 | 7.12 / 617.70 | 5 | 34 |
Average= | 7.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 37 | 14.97 | 541 | 300 | 0.30 / 603.93 | 5 | 10 |
2 | 7 | 2011.48 | 40 | 14.67 | 3540 | 2077 | 2.38 / 606.01 | 10 | 28 |
3 | 13 | 1922.80 | 20 | 14.65 | 3414 | 1000 | 3.38 / 607.01 | 4 | 32 |
4 | 13 | 1403.28 | 20 | 14.67 | 2637 | 774 | 4.15 / 607.78 | 4 | 38 |
5 | 13 | 760.04 | 20 | 14.82 | 1644 | 487 | 4.64 / 608.27 | 4 | 44 |
6 | 13 | 319.40 | 20 | 14.95 | 928 | 277 | 4.92 / 608.55 | 5 | 45 |
7 | 8 | 0.04 | 400 | 14.98 | 340 | 2037 | 6.95 / 610.58 | 5 | 34 |
Average= | 7.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 37 | 14.97 | 545 | 302 | 0.30 / 596.86 | 5 | 8 |
2 | 7 | 2004.36 | 40 | 14.68 | 3533 | 2075 | 2.38 / 598.93 | 8 | 29 |
3 | 13 | 1914.56 | 20 | 14.65 | 3386 | 992 | 3.37 / 599.93 | 4 | 32 |
4 | 13 | 1610.48 | 20 | 14.63 | 2954 | 864 | 4.23 / 600.79 | 4 | 37 |
5 | 13 | 857.08 | 20 | 14.80 | 1796 | 532 | 4.76 / 601.32 | 4 | 44 |
6 | 13 | 219.76 | 20 | 14.99 | 747 | 224 | 4.99 / 601.55 | 5 | 43 |
7 | 8 | -0.08 | 400 | 14.98 | 348 | 2085 | 7.07 / 603.63 | 5 | 43 |
Average= | 7.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 37 | 14.99 | 486 | 270 | 0.27 / 589.84 | 5 | 9 |
2 | 7 | 2009.04 | 40 | 14.67 | 3535 | 2074 | 2.34 / 591.92 | 9 | 29 |
3 | 13 | 1926.28 | 20 | 14.64 | 3407 | 998 | 3.34 / 592.92 | 4 | 32 |
4 | 13 | 1316.08 | 20 | 14.69 | 2502 | 735 | 4.08 / 593.65 | 4 | 39 |
5 | 13 | 998.88 | 20 | 14.74 | 2022 | 596 | 4.67 / 594.25 | 4 | 43 |
6 | 13 | 217.20 | 20 | 14.99 | 748 | 224 | 4.90 / 594.47 | 5 | 42 |
7 | 8 | -0.08 | 400 | 14.98 | 348 | 2085 | 6.98 / 596.56 | 5 | 46 |
Average= | 7.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 37 | 14.98 | 523 | 290 | 0.29 / 582.91 | 5 | 10 |
2 | 7 | 2003.28 | 40 | 14.68 | 3531 | 2073 | 2.36 / 584.98 | 10 | 28 |
3 | 13 | 1910.44 | 20 | 14.65 | 3378 | 990 | 3.35 / 585.97 | 4 | 32 |
4 | 13 | 1582.32 | 20 | 14.64 | 2905 | 851 | 4.20 / 586.82 | 4 | 37 |
5 | 13 | 918.44 | 20 | 14.78 | 1894 | 560 | 4.76 / 587.38 | 4 | 43 |
6 | 13 | 185.80 | 20 | 15.01 | 687 | 206 | 4.97 / 587.59 | 5 | 41 |
7 | 8 | -0.04 | 400 | 14.99 | 331 | 1985 | 6.95 / 589.57 | 5 | 38 |
Average= | 7.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 37 | 14.99 | 490 | 272 | 0.27 / 575.98 | 5 | 9 |
2 | 7 | 2006.48 | 40 | 14.68 | 3528 | 2072 | 2.34 / 578.05 | 9 | 29 |
3 | 13 | 1925.28 | 20 | 14.65 | 3402 | 997 | 3.34 / 579.04 | 4 | 32 |
4 | 13 | 1384.96 | 20 | 14.68 | 2612 | 767 | 4.11 / 579.81 | 4 | 38 |
5 | 13 | 844.24 | 20 | 14.80 | 1775 | 525 | 4.63 / 580.34 | 4 | 44 |
6 | 13 | 292.28 | 20 | 14.96 | 879 | 263 | 4.90 / 580.60 | 5 | 44 |
7 | 8 | 0.04 | 400 | 14.99 | 337 | 2021 | 6.92 / 582.62 | 5 | 39 |
Average= | 7.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 37 | 14.99 | 488 | 271 | 0.27 / 569.13 | 5 | 9 |
2 | 7 | 2003.44 | 40 | 14.68 | 3518 | 2066 | 2.34 / 571.20 | 9 | 28 |
3 | 13 | 1909.20 | 20 | 14.65 | 3380 | 990 | 3.33 / 572.19 | 4 | 32 |
4 | 13 | 1469.88 | 20 | 14.66 | 2748 | 806 | 4.13 / 573.00 | 4 | 38 |
5 | 13 | 709.72 | 20 | 14.85 | 1561 | 464 | 4.60 / 573.46 | 4 | 43 |
6 | 13 | 274.20 | 20 | 14.97 | 848 | 254 | 4.85 / 573.71 | 5 | 44 |
7 | 8 | -0.12 | 400 | 14.99 | 332 | 1991 | 6.84 / 575.70 | 5 | 40 |
Average= | 8.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 37 | 14.98 | 548 | 304 | 0.30 / 562.13 | 5 | 9 |
2 | 7 | 2003.72 | 40 | 14.68 | 3525 | 2070 | 2.37 / 564.20 | 9 | 29 |
3 | 13 | 1914.44 | 20 | 14.65 | 3396 | 995 | 3.37 / 565.20 | 4 | 32 |
4 | 13 | 1604.84 | 20 | 14.64 | 2937 | 860 | 4.23 / 566.06 | 4 | 37 |
5 | 13 | 944.40 | 20 | 14.78 | 1935 | 572 | 4.80 / 566.63 | 4 | 43 |
6 | 13 | 271.28 | 20 | 14.98 | 845 | 253 | 5.05 / 566.88 | 5 | 44 |
7 | 8 | 0.00 | 400 | 15.00 | 330 | 1980 | 7.03 / 568.86 | 5 | 45 |
Average= | 8.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 37 | 14.99 | 520 | 288 | 0.29 / 555.07 | 5 | 8 |
2 | 7 | 2004.80 | 40 | 14.68 | 3528 | 2072 | 2.36 / 557.14 | 8 | 29 |
3 | 13 | 1910.12 | 20 | 14.65 | 3398 | 996 | 3.36 / 558.13 | 4 | 32 |
4 | 13 | 1389.92 | 20 | 14.69 | 2616 | 769 | 4.12 / 558.90 | 4 | 39 |
5 | 13 | 862.12 | 20 | 14.80 | 1806 | 535 | 4.66 / 559.44 | 4 | 44 |
6 | 13 | 216.24 | 20 | 15.00 | 743 | 223 | 4.88 / 559.66 | 5 | 40 |
7 | 8 | 0.04 | 400 | 14.98 | 362 | 2169 | 7.05 / 561.83 | 5 | 40 |
Average= | 8.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 37 | 14.98 | 511 | 283 | 0.28 / 548.08 | 5 | 7 |
2 | 7 | 2017.16 | 40 | 14.68 | 3548 | 2083 | 2.37 / 550.16 | 7 | 29 |
3 | 13 | 1927.04 | 20 | 14.64 | 3419 | 1001 | 3.37 / 551.16 | 4 | 31 |
4 | 13 | 1507.08 | 20 | 14.66 | 2793 | 819 | 4.19 / 551.98 | 4 | 38 |
5 | 13 | 834.96 | 20 | 14.81 | 1757 | 520 | 4.71 / 552.50 | 4 | 44 |
6 | 13 | 284.20 | 20 | 14.98 | 862 | 258 | 4.97 / 552.76 | 5 | 43 |
7 | 8 | -0.12 | 400 | 15.00 | 337 | 2022 | 6.99 / 554.78 | 5 | 45 |
Average= | 8.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 37 | 14.99 | 534 | 296 | 0.30 / 541.05 | 5 | 8 |
2 | 7 | 2006.56 | 41 | 14.68 | 3527 | 2123 | 2.42 / 543.17 | 8 | 29 |
3 | 13 | 1918.76 | 20 | 14.64 | 3402 | 996 | 3.42 / 544.17 | 4 | 32 |
4 | 13 | 1388.64 | 20 | 14.69 | 2616 | 769 | 4.18 / 544.94 | 4 | 39 |
5 | 13 | 741.76 | 20 | 14.84 | 1616 | 480 | 4.66 / 545.42 | 5 | 44 |
6 | 13 | 214.52 | 20 | 15.00 | 734 | 220 | 4.88 / 545.64 | 5 | 40 |
7 | 13 | 28.12 | 20 | 15.06 | 386 | 116 | 5.00 / 545.75 | 5 | 21 |
8 | 8 | -0.04 | 400 | 14.99 | 340 | 2039 | 7.04 / 547.79 | 5 | 45 |
Average= | 8.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 37 | 14.99 | 514 | 285 | 0.29 / 534.03 | 5 | 8 |
2 | 7 | 2005.28 | 40 | 14.68 | 3537 | 2077 | 2.36 / 536.11 | 8 | 29 |
3 | 13 | 1921.32 | 20 | 14.65 | 3417 | 1001 | 3.36 / 537.11 | 4 | 32 |
4 | 13 | 1391.12 | 20 | 14.69 | 2618 | 769 | 4.13 / 537.88 | 4 | 39 |
5 | 13 | 1062.60 | 20 | 14.74 | 2120 | 625 | 4.76 / 538.51 | 4 | 43 |
6 | 13 | 264.92 | 20 | 14.99 | 834 | 250 | 5.01 / 538.76 | 5 | 43 |
7 | 8 | -0.24 | 400 | 15.00 | 333 | 1998 | 7.01 / 540.75 | 5 | 42 |
Average= | 8.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 37 | 14.98 | 517 | 287 | 0.29 / 527.01 | 5 | 8 |
2 | 7 | 2004.24 | 40 | 14.68 | 3525 | 2070 | 2.36 / 529.08 | 8 | 29 |
3 | 13 | 1907.32 | 20 | 14.65 | 3375 | 989 | 3.35 / 530.06 | 4 | 32 |
4 | 13 | 1489.44 | 20 | 14.66 | 2775 | 814 | 4.16 / 530.88 | 4 | 38 |
5 | 13 | 829.56 | 20 | 14.82 | 1750 | 519 | 4.68 / 531.40 | 4 | 44 |
6 | 13 | 286.24 | 20 | 14.98 | 862 | 258 | 4.94 / 531.66 | 5 | 43 |
7 | 13 | 20.28 | 20 | 15.07 | 374 | 113 | 5.05 / 531.77 | 5 | 17 |
8 | 8 | 0.00 | 400 | 15.00 | 330 | 1980 | 7.03 / 533.75 | 5 | 49 |
Average= | 8.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 37 | 14.99 | 513 | 285 | 0.28 / 519.82 | 5 | 8 |
2 | 7 | 2009.04 | 40 | 14.68 | 3528 | 2072 | 2.36 / 521.89 | 8 | 28 |
3 | 13 | 1925.28 | 20 | 14.65 | 3404 | 997 | 3.35 / 522.89 | 4 | 32 |
4 | 13 | 1490.92 | 20 | 14.66 | 2776 | 814 | 4.17 / 523.70 | 4 | 38 |
5 | 13 | 933.04 | 20 | 14.79 | 1914 | 566 | 4.73 / 524.27 | 4 | 43 |
6 | 13 | 270.32 | 20 | 14.99 | 836 | 251 | 4.98 / 524.52 | 5 | 43 |
7 | 13 | 37.64 | 20 | 15.06 | 408 | 123 | 5.11 / 524.64 | 5 | 26 |
8 | 8 | 0.04 | 400 | 14.99 | 347 | 2081 | 7.19 / 526.72 | 5 | 44 |
Average= | 8.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 37 | 14.99 | 530 | 294 | 0.29 / 512.98 | 5 | 8 |
2 | 7 | 2003.80 | 40 | 14.67 | 3522 | 2067 | 2.36 / 515.04 | 8 | 29 |
3 | 13 | 1913.00 | 20 | 14.65 | 3387 | 992 | 3.35 / 516.03 | 4 | 32 |
4 | 13 | 1401.84 | 20 | 14.68 | 2640 | 775 | 4.13 / 516.81 | 4 | 38 |
5 | 13 | 772.68 | 20 | 14.84 | 1665 | 494 | 4.62 / 517.30 | 4 | 44 |
6 | 13 | 239.80 | 20 | 15.00 | 785 | 235 | 4.86 / 517.54 | 5 | 43 |
7 | 8 | -0.04 | 400 | 15.00 | 332 | 1992 | 6.85 / 519.53 | 5 | 40 |
Average= | 8.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 37 | 14.99 | 504 | 280 | 0.28 / 505.90 | 5 | 7 |
2 | 7 | 2014.68 | 40 | 14.67 | 3534 | 2074 | 2.35 / 507.97 | 7 | 28 |
3 | 13 | 1920.12 | 20 | 14.64 | 3408 | 998 | 3.35 / 508.97 | 4 | 31 |
4 | 13 | 1494.32 | 20 | 14.66 | 2784 | 816 | 4.17 / 509.79 | 4 | 37 |
5 | 13 | 851.04 | 20 | 14.81 | 1784 | 528 | 4.70 / 510.32 | 4 | 43 |
6 | 13 | 397.36 | 20 | 14.94 | 1051 | 314 | 5.01 / 510.63 | 5 | 45 |
7 | 8 | -0.04 | 400 | 15.00 | 342 | 2052 | 7.06 / 512.68 | 5 | 47 |
Average= | 8.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 37 | 15.01 | 498 | 277 | 0.28 / 498.62 | 5 | 8 |
2 | 7 | 2005.32 | 40 | 14.67 | 3539 | 2077 | 2.35 / 500.70 | 8 | 29 |
3 | 13 | 1917.68 | 20 | 14.65 | 3397 | 995 | 3.35 / 501.69 | 4 | 32 |
4 | 13 | 1504.48 | 20 | 14.66 | 2791 | 818 | 4.17 / 502.51 | 4 | 38 |
5 | 13 | 957.16 | 20 | 14.78 | 1956 | 578 | 4.75 / 503.09 | 4 | 43 |
6 | 13 | 302.20 | 20 | 14.98 | 893 | 268 | 5.01 / 503.36 | 5 | 43 |
7 | 13 | 20.52 | 20 | 15.07 | 403 | 121 | 5.13 / 503.48 | 5 | 18 |
8 | 8 | -0.08 | 400 | 14.99 | 357 | 2141 | 7.27 / 505.62 | 5 | 57 |
Average= | 8.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 37 | 14.99 | 512 | 284 | 0.28 / 491.75 | 5 | 9 |
2 | 7 | 2007.92 | 40 | 14.67 | 3536 | 2075 | 2.36 / 493.82 | 9 | 30 |
3 | 13 | 1925.16 | 20 | 14.65 | 3397 | 995 | 3.35 / 494.82 | 4 | 34 |
4 | 13 | 1408.12 | 20 | 14.68 | 2646 | 777 | 4.13 / 495.59 | 4 | 40 |
5 | 13 | 862.76 | 20 | 14.81 | 1802 | 534 | 4.66 / 496.13 | 4 | 45 |
6 | 13 | 299.24 | 20 | 14.98 | 889 | 266 | 4.93 / 496.39 | 5 | 45 |
7 | 8 | 0.00 | 400 | 15.01 | 325 | 1951 | 6.88 / 498.35 | 5 | 45 |
Average= | 8.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 37 | 14.99 | 519 | 288 | 0.29 / 484.89 | 5 | 9 |
2 | 7 | 2007.00 | 41 | 14.67 | 3526 | 2121 | 2.41 / 487.01 | 9 | 31 |
3 | 13 | 1921.20 | 20 | 14.64 | 3405 | 997 | 3.41 / 488.00 | 4 | 34 |
4 | 13 | 1398.16 | 20 | 14.69 | 2625 | 771 | 4.18 / 488.77 | 4 | 40 |
5 | 13 | 774.12 | 20 | 14.84 | 1664 | 494 | 4.67 / 489.27 | 5 | 45 |
6 | 13 | 233.08 | 20 | 15.00 | 770 | 231 | 4.90 / 489.50 | 5 | 44 |
7 | 8 | 0.08 | 400 | 15.01 | 327 | 1963 | 6.87 / 491.46 | 5 | 53 |
Average= | 8.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 37 | 15.00 | 499 | 277 | 0.28 / 477.73 | 5 | 10 |
2 | 7 | 2004.60 | 40 | 14.68 | 3530 | 2073 | 2.35 / 479.81 | 10 | 30 |
3 | 13 | 1918.04 | 20 | 14.66 | 3402 | 997 | 3.35 / 480.80 | 4 | 34 |
4 | 13 | 1505.00 | 20 | 14.67 | 2793 | 819 | 4.17 / 481.62 | 4 | 39 |
5 | 13 | 1057.96 | 20 | 14.75 | 2105 | 621 | 4.79 / 482.24 | 4 | 44 |
6 | 13 | 466.64 | 20 | 14.92 | 1170 | 349 | 5.14 / 482.59 | 5 | 47 |
7 | 8 | -0.08 | 400 | 15.00 | 334 | 2004 | 7.14 / 484.60 | 5 | 42 |
Average= | 8.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 37 | 14.98 | 515 | 285 | 0.29 / 470.92 | 5 | 9 |
2 | 7 | 2004.64 | 40 | 14.67 | 3522 | 2067 | 2.35 / 472.99 | 9 | 28 |
3 | 13 | 1915.80 | 20 | 14.64 | 3400 | 996 | 3.35 / 473.98 | 4 | 31 |
4 | 13 | 1405.36 | 20 | 14.69 | 2644 | 777 | 4.12 / 474.76 | 4 | 38 |
5 | 13 | 786.40 | 20 | 14.84 | 1677 | 498 | 4.62 / 475.26 | 4 | 43 |
6 | 13 | 248.56 | 20 | 15.00 | 797 | 239 | 4.86 / 475.49 | 5 | 42 |
7 | 8 | 0.04 | 400 | 15.00 | 327 | 1962 | 6.82 / 477.46 | 5 | 42 |
Average= | 8.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 37 | 14.99 | 534 | 296 | 0.30 / 463.95 | 5 | 8 |
2 | 7 | 2003.52 | 40 | 14.68 | 3525 | 2070 | 2.37 / 466.02 | 8 | 28 |
3 | 13 | 1906.68 | 20 | 14.65 | 3379 | 990 | 3.36 / 467.01 | 4 | 32 |
4 | 13 | 1391.96 | 20 | 14.70 | 2622 | 771 | 4.13 / 467.78 | 4 | 38 |
5 | 13 | 955.16 | 20 | 14.78 | 1945 | 575 | 4.70 / 468.35 | 4 | 43 |
6 | 13 | 272.16 | 20 | 14.99 | 840 | 252 | 4.95 / 468.61 | 5 | 43 |
7 | 8 | 0.04 | 400 | 15.00 | 338 | 2028 | 6.98 / 470.63 | 5 | 43 |
Average= | 8.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 37 | 14.98 | 520 | 288 | 0.29 / 457.08 | 5 | 9 |
2 | 7 | 2004.92 | 40 | 14.68 | 3522 | 2068 | 2.36 / 459.15 | 9 | 29 |
3 | 13 | 1914.40 | 20 | 14.65 | 3395 | 995 | 3.35 / 460.15 | 4 | 32 |
4 | 13 | 1490.04 | 20 | 14.67 | 2759 | 809 | 4.16 / 460.96 | 4 | 37 |
5 | 13 | 731.12 | 20 | 14.85 | 1595 | 474 | 4.63 / 461.43 | 4 | 43 |
6 | 13 | 298.24 | 20 | 14.97 | 885 | 265 | 4.90 / 461.70 | 5 | 44 |
7 | 8 | 0.08 | 400 | 15.00 | 326 | 1956 | 6.86 / 463.65 | 5 | 43 |
Average= | 8.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 37 | 14.97 | 532 | 295 | 0.29 / 450.05 | 5 | 9 |
2 | 7 | 2005.24 | 40 | 14.69 | 3531 | 2075 | 2.37 / 452.12 | 9 | 28 |
3 | 13 | 1919.44 | 20 | 14.66 | 3399 | 997 | 3.37 / 453.12 | 4 | 32 |
4 | 13 | 1491.96 | 20 | 14.67 | 2772 | 813 | 4.18 / 453.93 | 4 | 37 |
5 | 13 | 858.36 | 20 | 14.81 | 1795 | 532 | 4.71 / 454.46 | 4 | 43 |
6 | 13 | 305.52 | 20 | 14.97 | 903 | 270 | 4.98 / 454.73 | 5 | 43 |
7 | 8 | -0.16 | 400 | 14.99 | 344 | 2063 | 7.04 / 456.80 | 5 | 41 |
Average= | 8.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 37 | 14.96 | 552 | 306 | 0.31 / 443.13 | 5 | 9 |
2 | 7 | 2007.52 | 40 | 14.69 | 3534 | 2077 | 2.38 / 445.21 | 9 | 29 |
3 | 13 | 1920.20 | 20 | 14.66 | 3404 | 998 | 3.38 / 446.21 | 4 | 32 |
4 | 13 | 1395.52 | 20 | 14.69 | 2628 | 772 | 4.15 / 446.98 | 4 | 38 |
5 | 13 | 664.84 | 20 | 14.87 | 1493 | 444 | 4.60 / 447.42 | 4 | 44 |
6 | 13 | 245.08 | 20 | 14.99 | 796 | 239 | 4.83 / 447.66 | 5 | 43 |
7 | 8 | -0.08 | 400 | 14.99 | 349 | 2093 | 6.93 / 449.75 | 5 | 45 |
Average= | 8.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 37 | 14.97 | 518 | 287 | 0.29 / 435.96 | 5 | 9 |
2 | 7 | 2010.76 | 40 | 14.69 | 3540 | 2080 | 2.37 / 438.04 | 24 | 29 |
3 | 13 | 1820.76 | 20 | 14.68 | 3271 | 960 | 3.33 / 439.00 | 4 | 33 |
4 | 13 | 1416.80 | 20 | 14.69 | 2658 | 781 | 4.11 / 439.78 | 4 | 38 |
5 | 13 | 773.12 | 20 | 14.83 | 1669 | 495 | 4.60 / 440.28 | 4 | 44 |
6 | 13 | 338.04 | 20 | 14.96 | 965 | 289 | 4.89 / 440.57 | 5 | 44 |
7 | 8 | -0.12 | 400 | 14.97 | 377 | 2257 | 7.15 / 442.83 | 5 | 41 |
Average= | 8.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 37 | 14.98 | 534 | 296 | 0.30 / 428.99 | 5 | 8 |
2 | 7 | 2004.64 | 40 | 14.69 | 3529 | 2074 | 2.37 / 431.06 | 8 | 28 |
3 | 13 | 1916.56 | 20 | 14.67 | 3379 | 991 | 3.36 / 432.05 | 4 | 31 |
4 | 13 | 1313.24 | 20 | 14.71 | 2496 | 734 | 4.10 / 432.79 | 4 | 39 |
5 | 13 | 895.64 | 20 | 14.79 | 1856 | 549 | 4.64 / 433.34 | 4 | 43 |
6 | 13 | 236.64 | 20 | 15.00 | 784 | 235 | 4.88 / 433.57 | 5 | 43 |
7 | 8 | 0.00 | 400 | 14.99 | 351 | 2105 | 6.98 / 435.68 | 5 | 38 |
Average= | 8.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 37 | 14.98 | 536 | 297 | 0.30 / 422.03 | 5 | 9 |
2 | 7 | 2006.44 | 40 | 14.70 | 3524 | 2072 | 2.37 / 424.10 | 9 | 28 |
3 | 13 | 1916.64 | 20 | 14.67 | 3405 | 999 | 3.37 / 425.10 | 4 | 32 |
4 | 13 | 1480.72 | 20 | 14.67 | 2760 | 810 | 4.18 / 425.91 | 4 | 38 |
5 | 13 | 926.40 | 20 | 14.78 | 1905 | 563 | 4.74 / 426.48 | 4 | 43 |
6 | 13 | 252.80 | 20 | 14.99 | 808 | 242 | 4.98 / 426.72 | 5 | 43 |
7 | 8 | -0.08 | 400 | 15.00 | 329 | 1974 | 6.96 / 428.69 | 5 | 41 |
Average= | 8.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 37 | 14.98 | 535 | 297 | 0.30 / 414.98 | 5 | 9 |
2 | 7 | 2005.80 | 41 | 14.70 | 3535 | 2131 | 2.43 / 417.11 | 9 | 28 |
3 | 13 | 1919.72 | 20 | 14.68 | 3392 | 996 | 3.42 / 418.11 | 4 | 32 |
4 | 13 | 1479.68 | 20 | 14.68 | 2753 | 808 | 4.23 / 418.92 | 4 | 38 |
5 | 13 | 832.24 | 20 | 14.82 | 1751 | 519 | 4.75 / 419.44 | 4 | 43 |
6 | 13 | 285.44 | 20 | 14.98 | 863 | 259 | 5.01 / 419.69 | 5 | 43 |
7 | 8 | -0.04 | 400 | 15.00 | 340 | 2040 | 7.05 / 421.73 | 5 | 42 |
Average= | 8.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 37 | 14.97 | 535 | 296 | 0.30 / 408.02 | 5 | 9 |
2 | 7 | 2004.24 | 40 | 14.71 | 3518 | 2070 | 2.37 / 410.09 | 9 | 28 |
3 | 13 | 1920.28 | 20 | 14.69 | 3396 | 998 | 3.36 / 411.09 | 4 | 31 |
4 | 13 | 1411.40 | 20 | 14.70 | 2647 | 778 | 4.14 / 411.86 | 4 | 38 |
5 | 13 | 885.16 | 20 | 14.81 | 1837 | 544 | 4.69 / 412.41 | 4 | 43 |
6 | 13 | 243.84 | 20 | 15.00 | 791 | 237 | 4.92 / 412.65 | 5 | 43 |
7 | 8 | -0.04 | 400 | 15.00 | 340 | 2040 | 6.96 / 414.69 | 5 | 42 |
Average= | 8.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 37 | 15.00 | 533 | 296 | 0.30 / 400.79 | 5 | 9 |
2 | 7 | 2005.32 | 40 | 14.71 | 3530 | 2077 | 2.37 / 402.87 | 17 | 28 |
3 | 13 | 1914.12 | 20 | 14.68 | 3382 | 993 | 3.37 / 403.86 | 4 | 32 |
4 | 13 | 1485.80 | 20 | 14.68 | 2765 | 812 | 4.18 / 404.67 | 4 | 37 |
5 | 13 | 942.92 | 20 | 14.79 | 1928 | 570 | 4.75 / 405.24 | 4 | 43 |
6 | 13 | 371.80 | 20 | 14.96 | 1010 | 302 | 5.05 / 405.54 | 5 | 45 |
7 | 8 | 0.00 | 400 | 14.99 | 363 | 2177 | 7.23 / 407.72 | 5 | 53 |
Average= | 8.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 37 | 15.01 | 483 | 268 | 0.27 / 393.82 | 5 | 9 |
2 | 7 | 2014.12 | 40 | 14.71 | 3538 | 2082 | 2.35 / 395.90 | 9 | 28 |
3 | 13 | 1929.40 | 20 | 14.68 | 3428 | 1006 | 3.36 / 396.91 | 4 | 32 |
4 | 13 | 1512.84 | 20 | 14.69 | 2799 | 822 | 4.18 / 397.73 | 4 | 37 |
5 | 13 | 845.24 | 20 | 14.83 | 1772 | 526 | 4.70 / 398.25 | 4 | 43 |
6 | 13 | 213.08 | 20 | 15.02 | 742 | 223 | 4.93 / 398.48 | 5 | 42 |
7 | 8 | -0.04 | 400 | 15.01 | 336 | 2017 | 6.94 / 400.49 | 5 | 70 |
Average= | 8.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 37 | 14.98 | 540 | 299 | 0.30 / 386.91 | 5 | 9 |
2 | 7 | 2011.76 | 40 | 14.71 | 3544 | 2085 | 2.38 / 388.99 | 9 | 29 |
3 | 13 | 1929.60 | 20 | 14.69 | 3414 | 1003 | 3.39 / 390.00 | 4 | 32 |
4 | 13 | 1606.24 | 20 | 14.67 | 2943 | 863 | 4.25 / 390.86 | 4 | 37 |
5 | 13 | 833.96 | 20 | 14.84 | 1759 | 522 | 4.77 / 391.38 | 4 | 44 |
6 | 13 | 187.60 | 20 | 15.03 | 695 | 209 | 4.98 / 391.59 | 5 | 41 |
7 | 8 | 0.04 | 400 | 15.02 | 326 | 1959 | 6.94 / 393.55 | 5 | 44 |
Average= | 8.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 37 | 15.01 | 522 | 290 | 0.29 / 379.73 | 5 | 9 |
2 | 7 | 2013.00 | 41 | 14.72 | 3532 | 2132 | 2.42 / 381.86 | 9 | 28 |
3 | 13 | 1915.20 | 20 | 14.69 | 3400 | 999 | 3.42 / 382.86 | 4 | 32 |
4 | 13 | 1304.72 | 20 | 14.74 | 2487 | 733 | 4.15 / 383.59 | 4 | 39 |
5 | 13 | 789.52 | 20 | 14.85 | 1684 | 500 | 4.65 / 384.09 | 4 | 44 |
6 | 13 | 250.52 | 20 | 15.01 | 804 | 241 | 4.90 / 384.33 | 5 | 44 |
7 | 13 | 31.40 | 20 | 15.08 | 392 | 118 | 5.01 / 384.45 | 5 | 22 |
8 | 8 | -0.08 | 400 | 15.00 | 360 | 2160 | 7.17 / 386.61 | 5 | 45 |
Average= | 8.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 36 | 15.01 | 528 | 285 | 0.29 / 372.75 | 5 | 9 |
2 | 7 | 2015.36 | 40 | 14.72 | 3549 | 2090 | 2.37 / 374.84 | 9 | 28 |
3 | 13 | 1920.08 | 20 | 14.69 | 3431 | 1008 | 3.38 / 375.85 | 4 | 32 |
4 | 13 | 1601.40 | 20 | 14.68 | 2941 | 863 | 4.25 / 376.71 | 4 | 37 |
5 | 13 | 829.08 | 20 | 14.85 | 1755 | 521 | 4.77 / 377.24 | 4 | 44 |
6 | 13 | 181.32 | 20 | 15.05 | 681 | 205 | 4.97 / 377.44 | 5 | 41 |
7 | 8 | 0.00 | 400 | 15.03 | 332 | 1996 | 6.97 / 379.44 | 5 | 39 |
Average= | 8.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 36 | 15.01 | 513 | 277 | 0.28 / 365.86 | 5 | 9 |
2 | 7 | 2005.24 | 40 | 14.73 | 3522 | 2075 | 2.35 / 367.94 | 9 | 29 |
3 | 13 | 1917.88 | 20 | 14.70 | 3397 | 999 | 3.35 / 368.94 | 4 | 32 |
4 | 13 | 1389.36 | 20 | 14.73 | 2612 | 769 | 4.12 / 369.71 | 4 | 38 |
5 | 13 | 754.52 | 20 | 14.87 | 1635 | 486 | 4.61 / 370.19 | 4 | 44 |
6 | 13 | 221.36 | 20 | 15.03 | 745 | 224 | 4.83 / 370.42 | 5 | 43 |
7 | 8 | 0.04 | 400 | 15.03 | 341 | 2050 | 6.88 / 372.47 | 5 | 41 |
Average= | 8.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 37 | 15.03 | 487 | 271 | 0.27 / 359.08 | 5 | 9 |
2 | 7 | 2008.20 | 40 | 14.73 | 3529 | 2079 | 2.35 / 361.16 | 9 | 29 |
3 | 13 | 1917.48 | 20 | 14.70 | 3393 | 998 | 3.35 / 362.15 | 4 | 32 |
4 | 13 | 1472.04 | 20 | 14.72 | 2735 | 805 | 4.15 / 362.96 | 4 | 38 |
5 | 13 | 708.56 | 20 | 14.90 | 1554 | 463 | 4.62 / 363.42 | 4 | 44 |
6 | 13 | 195.24 | 20 | 15.05 | 702 | 211 | 4.83 / 363.63 | 5 | 41 |
7 | 8 | -0.12 | 400 | 15.03 | 325 | 1954 | 6.78 / 365.59 | 5 | 39 |
Average= | 8.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 37 | 15.03 | 507 | 282 | 0.28 / 352.11 | 5 | 9 |
2 | 7 | 2014.64 | 41 | 14.73 | 3540 | 2138 | 2.42 / 354.25 | 9 | 28 |
3 | 13 | 1921.16 | 20 | 14.70 | 3405 | 1001 | 3.42 / 355.25 | 4 | 32 |
4 | 13 | 1496.72 | 20 | 14.71 | 2782 | 818 | 4.24 / 356.07 | 4 | 38 |
5 | 13 | 843.32 | 20 | 14.86 | 1774 | 527 | 4.77 / 356.59 | 4 | 43 |
6 | 13 | 282.52 | 20 | 15.02 | 855 | 257 | 5.02 / 356.85 | 5 | 43 |
7 | 8 | 0.00 | 400 | 15.04 | 325 | 1955 | 6.98 / 358.81 | 5 | 40 |
Average= | 8.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 37 | 15.04 | 481 | 268 | 0.27 / 345.22 | 5 | 8 |
2 | 7 | 2005.68 | 40 | 14.74 | 3528 | 2080 | 2.35 / 347.30 | 8 | 28 |
3 | 13 | 1914.44 | 20 | 14.71 | 3388 | 997 | 3.34 / 348.29 | 4 | 32 |
4 | 13 | 1494.36 | 20 | 14.72 | 2772 | 816 | 4.16 / 349.11 | 4 | 37 |
5 | 13 | 741.88 | 20 | 14.90 | 1616 | 482 | 4.64 / 349.59 | 4 | 43 |
6 | 13 | 306.12 | 20 | 15.02 | 899 | 270 | 4.91 / 349.86 | 5 | 43 |
7 | 8 | -0.08 | 400 | 15.04 | 327 | 1967 | 6.88 / 351.83 | 5 | 44 |
Average= | 8.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 36 | 15.04 | 530 | 287 | 0.29 / 338.24 | 5 | 8 |
2 | 7 | 2006.12 | 40 | 14.74 | 3530 | 2081 | 2.37 / 340.32 | 8 | 28 |
3 | 13 | 1918.48 | 20 | 14.71 | 3408 | 1003 | 3.37 / 341.32 | 4 | 32 |
4 | 13 | 1478.68 | 20 | 14.73 | 2759 | 813 | 4.18 / 342.13 | 4 | 37 |
5 | 13 | 930.24 | 20 | 14.84 | 1910 | 567 | 4.75 / 342.70 | 4 | 43 |
6 | 13 | 359.04 | 20 | 15.01 | 984 | 295 | 5.05 / 343.00 | 5 | 44 |
7 | 8 | 0.00 | 400 | 15.05 | 324 | 1950 | 7.00 / 344.95 | 5 | 41 |
Average= | 8.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 36 | 15.05 | 509 | 276 | 0.28 / 331.28 | 5 | 8 |
2 | 7 | 2010.40 | 40 | 14.74 | 3529 | 2081 | 2.36 / 333.36 | 8 | 28 |
3 | 13 | 1918.96 | 20 | 14.72 | 3393 | 999 | 3.36 / 334.36 | 4 | 32 |
4 | 13 | 1387.56 | 20 | 14.76 | 2611 | 771 | 4.13 / 335.13 | 4 | 38 |
5 | 13 | 859.08 | 20 | 14.87 | 1795 | 534 | 4.66 / 335.66 | 4 | 43 |
6 | 13 | 314.76 | 20 | 15.03 | 905 | 272 | 4.93 / 335.93 | 5 | 43 |
7 | 8 | 0.00 | 400 | 15.06 | 335 | 2018 | 6.95 / 337.95 | 5 | 47 |
Average= | 8.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 36 | 15.05 | 532 | 288 | 0.29 / 324.36 | 5 | 8 |
2 | 7 | 2010.76 | 40 | 14.75 | 3541 | 2089 | 2.38 / 326.45 | 8 | 29 |
3 | 13 | 1927.24 | 20 | 14.71 | 3416 | 1005 | 3.38 / 327.45 | 4 | 32 |
4 | 13 | 1499.64 | 20 | 14.74 | 2792 | 823 | 4.21 / 328.28 | 4 | 38 |
5 | 13 | 836.64 | 20 | 14.88 | 1763 | 525 | 4.73 / 328.80 | 4 | 44 |
6 | 13 | 216.16 | 20 | 15.07 | 738 | 222 | 4.95 / 329.02 | 5 | 41 |
7 | 8 | 0.20 | 400 | 15.07 | 328 | 1977 | 6.93 / 331.00 | 5 | 49 |
Average= | 8.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 36 | 15.06 | 523 | 284 | 0.28 / 317.29 | 5 | 8 |
2 | 7 | 2004.40 | 40 | 14.75 | 3523 | 2079 | 2.36 / 319.37 | 8 | 29 |
3 | 13 | 1908.04 | 20 | 14.72 | 3400 | 1001 | 3.36 / 320.37 | 4 | 32 |
4 | 13 | 1481.84 | 20 | 14.75 | 2743 | 809 | 4.17 / 321.18 | 4 | 38 |
5 | 13 | 918.72 | 20 | 14.87 | 1897 | 564 | 4.74 / 321.74 | 4 | 43 |
6 | 13 | 355.60 | 20 | 15.02 | 981 | 295 | 5.03 / 322.03 | 5 | 45 |
7 | 8 | -0.04 | 400 | 15.06 | 338 | 2036 | 7.07 / 324.07 | 5 | 46 |
Average= | 9.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 36 | 15.05 | 521 | 282 | 0.28 / 310.46 | 5 | 8 |
2 | 7 | 2009.28 | 40 | 14.75 | 3530 | 2083 | 2.36 / 312.54 | 8 | 29 |
3 | 13 | 1917.04 | 20 | 14.73 | 3385 | 997 | 3.36 / 313.54 | 4 | 32 |
4 | 13 | 1289.28 | 20 | 14.80 | 2468 | 731 | 4.09 / 314.27 | 4 | 40 |
5 | 13 | 768.00 | 20 | 14.91 | 1654 | 493 | 4.59 / 314.76 | 4 | 44 |
6 | 13 | 225.32 | 20 | 15.07 | 756 | 228 | 4.81 / 314.99 | 5 | 42 |
7 | 8 | 0.04 | 400 | 15.07 | 334 | 2013 | 6.83 / 317.00 | 5 | 51 |
Average= | 9.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 36 | 15.06 | 522 | 283 | 0.28 / 303.36 | 5 | 8 |
2 | 7 | 2006.24 | 40 | 14.76 | 3529 | 2084 | 2.37 / 305.44 | 8 | 29 |
3 | 13 | 1915.44 | 20 | 14.73 | 3395 | 1000 | 3.37 / 306.44 | 4 | 32 |
4 | 13 | 1488.92 | 20 | 14.76 | 2773 | 819 | 4.19 / 307.26 | 4 | 38 |
5 | 13 | 928.60 | 20 | 14.87 | 1906 | 567 | 4.75 / 307.83 | 4 | 44 |
6 | 13 | 344.04 | 20 | 15.04 | 969 | 291 | 5.04 / 308.12 | 5 | 45 |
7 | 8 | -0.04 | 400 | 15.07 | 341 | 2056 | 7.10 / 310.18 | 5 | 45 |
Average= | 9.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 36 | 15.07 | 527 | 286 | 0.29 / 296.43 | 5 | 8 |
2 | 7 | 2012.72 | 40 | 14.76 | 3538 | 2089 | 2.37 / 298.52 | 8 | 29 |
3 | 13 | 1918.00 | 20 | 14.73 | 3397 | 1001 | 3.38 / 299.52 | 4 | 32 |
4 | 13 | 1386.72 | 20 | 14.79 | 2619 | 775 | 4.15 / 300.30 | 4 | 39 |
5 | 13 | 841.88 | 20 | 14.91 | 1771 | 528 | 4.68 / 300.83 | 5 | 44 |
6 | 13 | 209.52 | 20 | 15.09 | 727 | 219 | 4.90 / 301.04 | 5 | 43 |
7 | 8 | 0.04 | 400 | 15.08 | 337 | 2033 | 6.93 / 303.08 | 5 | 48 |
Average= | 9.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 36 | 15.07 | 514 | 279 | 0.28 / 289.45 | 5 | 8 |
2 | 7 | 2014.24 | 40 | 14.76 | 3542 | 2091 | 2.37 / 291.54 | 8 | 29 |
3 | 13 | 1924.00 | 20 | 14.73 | 3422 | 1008 | 3.38 / 292.55 | 4 | 32 |
4 | 13 | 1405.80 | 20 | 14.78 | 2642 | 781 | 4.16 / 293.33 | 4 | 39 |
5 | 13 | 863.40 | 20 | 14.90 | 1811 | 540 | 4.70 / 293.87 | 4 | 44 |
6 | 13 | 306.36 | 20 | 15.06 | 905 | 273 | 4.97 / 294.14 | 5 | 45 |
7 | 8 | 0.00 | 400 | 15.08 | 332 | 2003 | 6.97 / 296.15 | 5 | 47 |
Average= | 9.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 36 | 15.09 | 501 | 272 | 0.27 / 282.39 | 5 | 7 |
2 | 7 | 2010.32 | 40 | 14.76 | 3534 | 2086 | 2.36 / 284.48 | 7 | 29 |
3 | 13 | 1812.32 | 20 | 14.75 | 3247 | 958 | 3.32 / 285.44 | 4 | 34 |
4 | 13 | 1610.08 | 20 | 14.74 | 2943 | 868 | 4.18 / 286.30 | 4 | 37 |
5 | 13 | 711.64 | 20 | 14.95 | 1573 | 470 | 4.65 / 286.77 | 4 | 45 |
6 | 13 | 183.04 | 20 | 15.11 | 683 | 206 | 4.86 / 286.98 | 5 | 42 |
7 | 13 | 40.76 | 20 | 15.15 | 408 | 124 | 4.98 / 287.10 | 5 | 25 |
8 | 8 | -0.04 | 400 | 15.08 | 343 | 2069 | 7.05 / 289.17 | 5 | 58 |
Average= | 9.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 36 | 15.09 | 495 | 269 | 0.27 / 275.57 | 5 | 7 |
2 | 7 | 2011.40 | 40 | 14.76 | 3543 | 2092 | 2.36 / 277.66 | 7 | 29 |
3 | 13 | 1824.96 | 20 | 14.75 | 3266 | 963 | 3.32 / 278.63 | 4 | 33 |
4 | 13 | 1409.36 | 20 | 14.79 | 2642 | 782 | 4.11 / 279.41 | 4 | 39 |
5 | 13 | 761.16 | 20 | 14.94 | 1645 | 492 | 4.60 / 279.90 | 4 | 45 |
6 | 13 | 222.96 | 20 | 15.10 | 754 | 228 | 4.82 / 280.13 | 5 | 43 |
7 | 8 | -0.04 | 400 | 15.09 | 330 | 1992 | 6.82 / 282.12 | 5 | 50 |
Average= | 9.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 36 | 15.09 | 504 | 274 | 0.27 / 268.59 | 5 | 7 |
2 | 7 | 2004.88 | 40 | 14.77 | 3518 | 2078 | 2.35 / 270.67 | 7 | 29 |
3 | 13 | 1914.00 | 20 | 14.74 | 3407 | 1004 | 3.36 / 271.67 | 4 | 32 |
4 | 13 | 1491.36 | 20 | 14.78 | 2762 | 816 | 4.17 / 272.49 | 4 | 38 |
5 | 13 | 841.68 | 20 | 14.92 | 1775 | 530 | 4.70 / 273.02 | 4 | 44 |
6 | 13 | 189.64 | 20 | 15.12 | 694 | 210 | 4.91 / 273.23 | 5 | 41 |
7 | 13 | 18.36 | 20 | 15.17 | 367 | 111 | 5.02 / 273.34 | 5 | 18 |
8 | 8 | -0.08 | 400 | 15.10 | 325 | 1963 | 6.99 / 275.30 | 5 | 81 |
Average= | 9.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 36 | 15.07 | 512 | 278 | 0.28 / 261.63 | 5 | 7 |
2 | 7 | 2007.32 | 40 | 14.77 | 3536 | 2089 | 2.37 / 263.72 | 7 | 28 |
3 | 13 | 1920.40 | 20 | 14.76 | 3396 | 1002 | 3.37 / 264.72 | 4 | 32 |
4 | 13 | 1498.40 | 20 | 14.78 | 2779 | 821 | 4.19 / 265.55 | 4 | 38 |
5 | 13 | 842.52 | 20 | 14.93 | 1784 | 533 | 4.72 / 266.08 | 4 | 44 |
6 | 13 | 299.32 | 20 | 15.08 | 885 | 267 | 4.99 / 266.35 | 5 | 44 |
7 | 8 | 0.00 | 400 | 15.11 | 326 | 1970 | 6.96 / 268.32 | 5 | 55 |
Average= | 9.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 36 | 15.10 | 508 | 276 | 0.28 / 254.38 | 5 | 7 |
2 | 7 | 2005.88 | 40 | 14.77 | 3541 | 2092 | 2.37 / 256.47 | 7 | 29 |
3 | 13 | 1911.36 | 20 | 14.76 | 3388 | 1000 | 3.37 / 257.47 | 4 | 32 |
4 | 13 | 1375.20 | 20 | 14.82 | 2599 | 770 | 4.14 / 258.25 | 4 | 39 |
5 | 13 | 933.20 | 20 | 14.90 | 1923 | 573 | 4.71 / 258.82 | 4 | 44 |
6 | 13 | 249.00 | 20 | 15.10 | 801 | 242 | 4.95 / 259.06 | 5 | 43 |
7 | 13 | 13.40 | 20 | 15.17 | 362 | 110 | 5.06 / 259.17 | 5 | 14 |
8 | 8 | -0.08 | 400 | 15.09 | 362 | 2185 | 7.25 / 261.36 | 5 | 62 |
Average= | 9.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 36 | 15.09 | 524 | 285 | 0.28 / 247.37 | 5 | 7 |
2 | 7 | 2006.40 | 40 | 14.78 | 3524 | 2083 | 2.37 / 249.45 | 7 | 29 |
3 | 13 | 1919.36 | 20 | 14.76 | 3414 | 1008 | 3.38 / 250.46 | 4 | 32 |
4 | 13 | 1512.16 | 20 | 14.79 | 2810 | 831 | 4.21 / 251.29 | 4 | 38 |
5 | 13 | 746.00 | 20 | 14.97 | 1622 | 486 | 4.69 / 251.77 | 4 | 44 |
6 | 13 | 315.04 | 20 | 15.08 | 919 | 277 | 4.97 / 252.05 | 5 | 44 |
7 | 8 | -0.04 | 400 | 15.11 | 340 | 2055 | 7.02 / 254.11 | 5 | 52 |
Average= | 9.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 36 | 15.11 | 532 | 289 | 0.29 / 240.07 | 5 | 8 |
2 | 7 | 2006.68 | 40 | 14.78 | 3527 | 2085 | 2.37 / 242.16 | 8 | 29 |
3 | 13 | 1925.04 | 20 | 14.76 | 3426 | 1011 | 3.39 / 243.17 | 4 | 32 |
4 | 13 | 1507.68 | 20 | 14.80 | 2792 | 826 | 4.21 / 244.00 | 4 | 38 |
5 | 13 | 1042.84 | 20 | 14.88 | 2084 | 620 | 4.83 / 244.62 | 4 | 43 |
6 | 13 | 243.48 | 20 | 15.11 | 790 | 239 | 5.07 / 244.86 | 5 | 43 |
7 | 13 | 31.32 | 20 | 15.18 | 386 | 117 | 5.19 / 244.97 | 5 | 20 |
8 | 8 | 0.00 | 400 | 15.10 | 349 | 2108 | 7.30 / 247.08 | 5 | 68 |
Average= | 9.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 36 | 15.12 | 533 | 290 | 0.29 / 233.04 | 5 | 7 |
2 | 7 | 2006.32 | 40 | 14.79 | 3547 | 2098 | 2.39 / 235.13 | 7 | 29 |
3 | 13 | 1920.96 | 20 | 14.77 | 3413 | 1008 | 3.40 / 236.14 | 4 | 32 |
4 | 13 | 1483.12 | 20 | 14.81 | 2764 | 819 | 4.22 / 236.96 | 4 | 38 |
5 | 13 | 921.56 | 20 | 14.93 | 1900 | 567 | 4.78 / 237.53 | 4 | 44 |
6 | 13 | 240.36 | 20 | 15.12 | 784 | 237 | 5.02 / 237.77 | 5 | 43 |
7 | 8 | -0.08 | 400 | 15.12 | 334 | 2020 | 7.04 / 239.79 | 5 | 55 |
Average= | 9.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 36 | 15.12 | 536 | 292 | 0.29 / 226.00 | 5 | 8 |
2 | 7 | 2006.04 | 40 | 14.79 | 3539 | 2094 | 2.39 / 228.10 | 8 | 29 |
3 | 13 | 1923.52 | 20 | 14.77 | 3407 | 1006 | 3.39 / 229.10 | 4 | 33 |
4 | 13 | 1506.04 | 20 | 14.80 | 2813 | 833 | 4.22 / 229.94 | 4 | 38 |
5 | 13 | 845.28 | 20 | 14.95 | 1785 | 534 | 4.76 / 230.47 | 4 | 45 |
6 | 13 | 293.32 | 20 | 15.11 | 879 | 266 | 5.02 / 230.74 | 5 | 44 |
7 | 8 | -0.12 | 400 | 15.13 | 332 | 2009 | 7.03 / 232.75 | 5 | 61 |
Average= | 10.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 36 | 15.12 | 513 | 279 | 0.28 / 218.99 | 5 | 8 |
2 | 7 | 2003.56 | 40 | 14.79 | 3541 | 2095 | 2.37 / 221.09 | 8 | 30 |
3 | 13 | 1911.24 | 20 | 14.77 | 3395 | 1003 | 3.38 / 222.09 | 4 | 33 |
4 | 13 | 1485.80 | 20 | 14.81 | 2764 | 819 | 4.20 / 222.91 | 4 | 40 |
5 | 13 | 725.84 | 20 | 14.99 | 1594 | 478 | 4.67 / 223.39 | 5 | 45 |
6 | 13 | 290.24 | 20 | 15.11 | 872 | 264 | 4.94 / 223.65 | 5 | 44 |
7 | 8 | -0.08 | 400 | 15.13 | 341 | 2064 | 7.00 / 225.71 | 5 | 55 |
Average= | 10.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 36 | 15.11 | 536 | 292 | 0.29 / 212.13 | 5 | 8 |
2 | 7 | 2004.16 | 40 | 14.80 | 3523 | 2086 | 2.38 / 214.21 | 8 | 30 |
3 | 13 | 1911.56 | 20 | 14.78 | 3404 | 1006 | 3.38 / 215.22 | 4 | 34 |
4 | 13 | 1390.40 | 20 | 14.85 | 2627 | 780 | 4.16 / 216.00 | 4 | 41 |
5 | 13 | 670.20 | 20 | 15.02 | 1499 | 450 | 4.61 / 216.45 | 4 | 46 |
6 | 13 | 236.68 | 20 | 15.13 | 777 | 235 | 4.85 / 216.68 | 5 | 44 |
7 | 8 | 0.00 | 400 | 15.13 | 335 | 2027 | 6.88 / 218.71 | 5 | 52 |
Average= | 10.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 36 | 15.12 | 519 | 283 | 0.28 / 205.11 | 5 | 8 |
2 | 7 | 2009.68 | 41 | 14.79 | 3541 | 2147 | 2.43 / 207.26 | 8 | 31 |
3 | 13 | 1811.44 | 20 | 14.80 | 3245 | 961 | 3.39 / 208.22 | 4 | 36 |
4 | 13 | 1410.88 | 20 | 14.84 | 2647 | 786 | 4.18 / 209.01 | 4 | 41 |
5 | 13 | 857.04 | 20 | 14.96 | 1799 | 538 | 4.71 / 209.55 | 4 | 46 |
6 | 13 | 286.80 | 20 | 15.12 | 866 | 262 | 4.98 / 209.81 | 5 | 46 |
7 | 8 | -0.08 | 400 | 15.13 | 335 | 2027 | 7.00 / 211.84 | 5 | 49 |
Average= | 10.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 36 | 15.13 | 516 | 281 | 0.28 / 198.09 | 5 | 9 |
2 | 7 | 2011.12 | 40 | 14.81 | 3534 | 2094 | 2.37 / 200.18 | 9 | 31 |
3 | 13 | 1916.24 | 20 | 14.79 | 3399 | 1005 | 3.38 / 201.19 | 4 | 35 |
4 | 13 | 1403.48 | 20 | 14.85 | 2646 | 786 | 4.17 / 201.97 | 4 | 41 |
5 | 13 | 864.52 | 20 | 14.96 | 1811 | 542 | 4.71 / 202.51 | 4 | 46 |
6 | 13 | 211.24 | 20 | 15.15 | 735 | 223 | 4.93 / 202.74 | 5 | 43 |
7 | 8 | 0.04 | 400 | 15.14 | 346 | 2095 | 7.03 / 204.83 | 5 | 62 |
Average= | 10.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 36 | 15.13 | 525 | 286 | 0.29 / 191.15 | 5 | 9 |
2 | 7 | 2003.60 | 40 | 14.81 | 3541 | 2098 | 2.38 / 193.25 | 9 | 31 |
3 | 13 | 1911.60 | 20 | 14.79 | 3407 | 1008 | 3.39 / 194.25 | 4 | 34 |
4 | 13 | 1289.64 | 20 | 14.88 | 2477 | 737 | 4.13 / 194.99 | 4 | 42 |
5 | 13 | 756.68 | 20 | 15.00 | 1646 | 494 | 4.62 / 195.48 | 5 | 46 |
6 | 13 | 219.44 | 20 | 15.15 | 746 | 226 | 4.85 / 195.71 | 5 | 43 |
7 | 8 | -0.04 | 400 | 15.14 | 346 | 2095 | 6.94 / 197.81 | 5 | 60 |
Average= | 10.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 36 | 15.14 | 485 | 264 | 0.26 / 184.15 | 5 | 10 |
2 | 7 | 2003.76 | 40 | 14.81 | 3544 | 2099 | 2.36 / 186.25 | 10 | 31 |
3 | 13 | 1910.68 | 20 | 14.80 | 3403 | 1007 | 3.37 / 187.26 | 4 | 34 |
4 | 13 | 1378.88 | 20 | 14.86 | 2610 | 776 | 4.15 / 188.03 | 4 | 42 |
5 | 13 | 935.28 | 20 | 14.95 | 1923 | 575 | 4.72 / 188.61 | 4 | 46 |
6 | 13 | 258.56 | 20 | 15.14 | 817 | 247 | 4.97 / 188.86 | 5 | 45 |
7 | 8 | -0.04 | 400 | 15.15 | 331 | 2006 | 6.98 / 190.86 | 5 | 55 |
Average= | 11.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 36 | 15.14 | 484 | 264 | 0.26 / 177.26 | 5 | 10 |
2 | 7 | 2003.64 | 40 | 14.81 | 3531 | 2092 | 2.36 / 179.35 | 10 | 31 |
3 | 13 | 1910.20 | 20 | 14.80 | 3398 | 1006 | 3.36 / 180.36 | 4 | 35 |
4 | 13 | 1368.20 | 20 | 14.87 | 2596 | 772 | 4.13 / 181.13 | 4 | 42 |
5 | 13 | 921.08 | 20 | 14.96 | 1902 | 569 | 4.70 / 181.70 | 4 | 46 |
6 | 13 | 239.36 | 20 | 15.15 | 781 | 237 | 4.94 / 181.93 | 5 | 45 |
7 | 8 | 0.00 | 400 | 15.16 | 322 | 1953 | 6.89 / 183.89 | 5 | 53 |
Average= | 11.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 36 | 15.13 | 549 | 299 | 0.30 / 170.14 | 5 | 12 |
2 | 7 | 2011.08 | 40 | 14.82 | 3532 | 2094 | 2.39 / 172.23 | 26 | 31 |
3 | 13 | 1914.08 | 20 | 14.81 | 3389 | 1004 | 3.40 / 173.24 | 4 | 35 |
4 | 13 | 1492.96 | 20 | 14.84 | 2789 | 828 | 4.22 / 174.06 | 4 | 41 |
5 | 13 | 825.36 | 20 | 14.99 | 1750 | 525 | 4.75 / 174.59 | 4 | 47 |
6 | 13 | 604.92 | 20 | 15.03 | 1395 | 419 | 5.17 / 175.01 | 5 | 48 |
7 | 8 | -0.04 | 400 | 15.15 | 328 | 1988 | 7.16 / 177.00 | 5 | 42 |
Average= | 11.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 36 | 15.14 | 543 | 296 | 0.30 / 163.22 | 5 | 11 |
2 | 7 | 2010.52 | 40 | 14.82 | 3541 | 2099 | 2.40 / 165.32 | 11 | 31 |
3 | 13 | 1915.48 | 20 | 14.81 | 3395 | 1006 | 3.40 / 166.32 | 4 | 35 |
4 | 13 | 1402.52 | 20 | 14.87 | 2643 | 786 | 4.19 / 167.11 | 4 | 42 |
5 | 13 | 659.72 | 20 | 15.04 | 1487 | 447 | 4.63 / 167.56 | 5 | 47 |
6 | 13 | 231.28 | 20 | 15.16 | 773 | 234 | 4.87 / 167.79 | 5 | 46 |
7 | 8 | 0.04 | 400 | 15.16 | 338 | 2050 | 6.92 / 169.84 | 5 | 44 |
Average= | 12.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 36 | 15.15 | 491 | 268 | 0.27 / 156.20 | 5 | 11 |
2 | 7 | 2004.64 | 41 | 14.83 | 3519 | 2140 | 2.41 / 158.34 | 11 | 32 |
3 | 13 | 1915.08 | 20 | 14.81 | 3420 | 1013 | 3.42 / 159.36 | 4 | 35 |
4 | 13 | 1268.24 | 20 | 14.90 | 2443 | 728 | 4.15 / 160.08 | 4 | 43 |
5 | 13 | 847.20 | 20 | 14.99 | 1789 | 536 | 4.68 / 160.62 | 4 | 47 |
6 | 13 | 185.88 | 20 | 15.18 | 687 | 209 | 4.89 / 160.83 | 5 | 44 |
7 | 8 | 0.00 | 400 | 15.16 | 345 | 2092 | 6.99 / 162.92 | 5 | 46 |
Average= | 12.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 36 | 15.14 | 537 | 293 | 0.29 / 149.22 | 5 | 12 |
2 | 7 | 2011.84 | 40 | 14.83 | 3550 | 2106 | 2.40 / 151.32 | 12 | 32 |
3 | 13 | 1917.40 | 20 | 14.82 | 3396 | 1007 | 3.41 / 152.33 | 4 | 35 |
4 | 13 | 1479.16 | 20 | 14.86 | 2761 | 821 | 4.23 / 153.15 | 4 | 41 |
5 | 13 | 819.96 | 20 | 15.00 | 1744 | 523 | 4.75 / 153.67 | 4 | 47 |
6 | 13 | 273.64 | 20 | 15.15 | 845 | 256 | 5.00 / 153.93 | 5 | 46 |
7 | 8 | -0.08 | 400 | 15.16 | 331 | 2007 | 7.01 / 155.94 | 5 | 43 |
Average= | 12.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 36 | 15.15 | 531 | 290 | 0.29 / 142.28 | 5 | 12 |
2 | 7 | 2003.40 | 41 | 14.83 | 3537 | 2151 | 2.44 / 144.43 | 12 | 32 |
3 | 13 | 1910.16 | 20 | 14.83 | 3395 | 1007 | 3.45 / 145.43 | 4 | 35 |
4 | 13 | 1280.64 | 20 | 14.91 | 2467 | 736 | 4.18 / 146.17 | 4 | 43 |
5 | 13 | 742.44 | 20 | 15.02 | 1627 | 489 | 4.67 / 146.66 | 4 | 47 |
6 | 13 | 203.36 | 20 | 15.18 | 724 | 220 | 4.89 / 146.88 | 5 | 45 |
7 | 8 | -0.04 | 400 | 15.17 | 337 | 2045 | 6.94 / 148.92 | 5 | 45 |
Average= | 13.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 36 | 15.15 | 540 | 295 | 0.29 / 135.31 | 5 | 13 |
2 | 7 | 2012.36 | 41 | 14.83 | 3543 | 2154 | 2.45 / 137.46 | 13 | 32 |
3 | 13 | 1923.24 | 20 | 14.83 | 3412 | 1012 | 3.46 / 138.47 | 4 | 35 |
4 | 13 | 1396.00 | 20 | 14.89 | 2635 | 785 | 4.25 / 139.26 | 4 | 42 |
5 | 13 | 670.04 | 20 | 15.05 | 1501 | 452 | 4.70 / 139.71 | 4 | 47 |
6 | 13 | 231.96 | 20 | 15.17 | 767 | 233 | 4.93 / 139.94 | 5 | 45 |
7 | 8 | -0.04 | 400 | 15.17 | 337 | 2045 | 6.97 / 141.99 | 5 | 48 |
Average= | 14.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 36 | 15.15 | 555 | 303 | 0.30 / 128.39 | 5 | 12 |
2 | 7 | 2011.16 | 40 | 14.83 | 3554 | 2108 | 2.41 / 130.50 | 12 | 32 |
3 | 13 | 1928.04 | 20 | 14.83 | 3425 | 1016 | 3.43 / 131.51 | 4 | 35 |
4 | 13 | 1311.84 | 20 | 14.91 | 2509 | 748 | 4.17 / 132.26 | 4 | 43 |
5 | 13 | 886.64 | 20 | 14.99 | 1859 | 557 | 4.73 / 132.82 | 4 | 47 |
6 | 13 | 107.68 | 20 | 15.22 | 547 | 167 | 4.90 / 132.99 | 5 | 42 |
7 | 8 | -0.04 | 400 | 15.17 | 334 | 2027 | 6.93 / 135.01 | 5 | 47 |
Average= | 15.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 35 | 15.15 | 530 | 281 | 0.28 / 121.10 | 5 | 11 |
2 | 7 | 2008.44 | 40 | 14.85 | 3534 | 2099 | 2.38 / 123.20 | 11 | 32 |
3 | 13 | 1922.16 | 20 | 14.84 | 3410 | 1012 | 3.39 / 124.21 | 4 | 35 |
4 | 13 | 1477.28 | 20 | 14.88 | 2760 | 821 | 4.21 / 125.04 | 4 | 42 |
5 | 13 | 912.16 | 20 | 14.99 | 1895 | 568 | 4.78 / 125.60 | 4 | 47 |
6 | 13 | 551.08 | 20 | 15.07 | 1312 | 395 | 5.18 / 126.00 | 4 | 49 |
7 | 8 | 0.12 | 400 | 15.17 | 344 | 2087 | 7.26 / 128.09 | 5 | 61 |
Average= | 16.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 35 | 15.16 | 547 | 290 | 0.29 / 114.06 | 5 | 11 |
2 | 7 | 2008.72 | 40 | 14.85 | 3540 | 2103 | 2.39 / 116.16 | 11 | 32 |
3 | 13 | 1927.44 | 20 | 14.85 | 3414 | 1014 | 3.41 / 117.17 | 4 | 35 |
4 | 13 | 1489.16 | 20 | 14.88 | 2764 | 823 | 4.23 / 118.00 | 4 | 41 |
5 | 13 | 831.20 | 20 | 15.02 | 1761 | 529 | 4.76 / 118.52 | 4 | 47 |
6 | 13 | 264.48 | 20 | 15.17 | 828 | 251 | 5.01 / 118.78 | 5 | 46 |
7 | 8 | -0.12 | 400 | 15.18 | 337 | 2046 | 7.06 / 120.82 | 5 | 42 |
Average= | 17.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 35 | 15.18 | 510 | 271 | 0.27 / 107.13 | 5 | 12 |
2 | 7 | 2010.04 | 40 | 14.85 | 3540 | 2103 | 2.37 / 109.23 | 12 | 32 |
3 | 13 | 1822.80 | 20 | 14.87 | 3283 | 976 | 3.35 / 110.21 | 4 | 36 |
4 | 13 | 1305.60 | 20 | 14.93 | 2506 | 748 | 4.10 / 110.96 | 4 | 43 |
5 | 13 | 854.24 | 20 | 15.01 | 1800 | 540 | 4.64 / 111.50 | 4 | 47 |
6 | 13 | 279.40 | 20 | 15.17 | 859 | 261 | 4.90 / 111.76 | 5 | 47 |
7 | 8 | -0.20 | 400 | 15.18 | 331 | 2010 | 6.91 / 113.77 | 5 | 45 |
Average= | 18.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 35 | 15.18 | 511 | 271 | 0.27 / 100.29 | 5 | 12 |
2 | 7 | 2005.20 | 40 | 14.86 | 3527 | 2096 | 2.37 / 102.38 | 12 | 32 |
3 | 13 | 1907.84 | 20 | 14.86 | 3392 | 1008 | 3.38 / 103.39 | 4 | 35 |
4 | 13 | 1464.76 | 20 | 14.89 | 2745 | 817 | 4.19 / 104.21 | 4 | 41 |
5 | 13 | 676.00 | 20 | 15.07 | 1521 | 458 | 4.65 / 104.67 | 4 | 47 |
6 | 13 | 162.00 | 20 | 15.22 | 643 | 196 | 4.85 / 104.86 | 5 | 43 |
7 | 8 | 0.08 | 400 | 15.19 | 328 | 1993 | 6.84 / 106.86 | 5 | 46 |
Average= | 21.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 35 | 15.17 | 564 | 299 | 0.30 / 93.33 | 5 | 11 |
2 | 7 | 2008.72 | 40 | 14.87 | 3530 | 2100 | 2.40 / 95.43 | 11 | 32 |
3 | 13 | 1922.32 | 20 | 14.86 | 3416 | 1015 | 3.41 / 96.45 | 4 | 35 |
4 | 13 | 1593.24 | 20 | 14.87 | 2935 | 873 | 4.29 / 97.32 | 4 | 40 |
5 | 13 | 750.92 | 20 | 15.05 | 1639 | 493 | 4.78 / 97.81 | 4 | 47 |
6 | 13 | 211.44 | 20 | 15.20 | 736 | 224 | 5.00 / 98.04 | 5 | 45 |
7 | 8 | 0.00 | 400 | 15.19 | 326 | 1981 | 6.99 / 100.02 | 5 | 49 |
Average= | 25.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 35 | 15.17 | 570 | 303 | 0.30 / 86.21 | 5 | 11 |
2 | 7 | 2008.92 | 40 | 14.87 | 3535 | 2103 | 2.41 / 88.31 | 11 | 32 |
3 | 13 | 1928.16 | 20 | 14.87 | 3416 | 1016 | 3.42 / 89.33 | 4 | 35 |
4 | 13 | 1411.28 | 20 | 14.92 | 2655 | 792 | 4.21 / 90.12 | 4 | 42 |
5 | 13 | 864.68 | 20 | 15.02 | 1816 | 546 | 4.76 / 90.66 | 4 | 47 |
6 | 13 | 198.60 | 20 | 15.21 | 712 | 217 | 4.98 / 90.88 | 5 | 45 |
7 | 8 | 0.04 | 400 | 15.19 | 354 | 2151 | 7.13 / 93.03 | 5 | 52 |
Average= | 31.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 35 | 15.19 | 487 | 259 | 0.26 / 79.24 | 5 | 10 |
2 | 7 | 2007.08 | 40 | 14.88 | 3530 | 2101 | 2.36 / 81.34 | 10 | 32 |
3 | 13 | 1920.76 | 20 | 14.87 | 3405 | 1013 | 3.37 / 82.35 | 4 | 35 |
4 | 13 | 1498.72 | 20 | 14.90 | 2784 | 830 | 4.20 / 83.18 | 4 | 41 |
5 | 13 | 734.40 | 20 | 15.06 | 1613 | 486 | 4.69 / 83.67 | 4 | 47 |
6 | 13 | 200.32 | 20 | 15.21 | 719 | 219 | 4.91 / 83.89 | 5 | 45 |
7 | 8 | -0.04 | 400 | 15.20 | 332 | 2019 | 6.93 / 85.91 | 5 | 45 |
Average= | 42.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 35 | 15.19 | 512 | 272 | 0.27 / 72.33 | 5 | 11 |
2 | 7 | 2003.96 | 41 | 14.88 | 3537 | 2158 | 2.43 / 74.49 | 11 | 32 |
3 | 13 | 1913.16 | 20 | 14.88 | 3397 | 1011 | 3.44 / 75.50 | 4 | 36 |
4 | 13 | 1373.88 | 20 | 14.93 | 2593 | 774 | 4.22 / 76.28 | 4 | 43 |
5 | 13 | 821.72 | 20 | 15.04 | 1754 | 528 | 4.74 / 76.80 | 4 | 47 |
6 | 13 | 160.24 | 20 | 15.23 | 640 | 195 | 4.94 / 77.00 | 5 | 43 |
7 | 8 | -0.08 | 400 | 15.20 | 326 | 1982 | 6.92 / 78.98 | 5 | 53 |
Average= | 78.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 35 | 15.19 | 528 | 281 | 0.28 / 65.41 | 5 | 9 |
2 | 7 | 2003.52 | 40 | 14.89 | 3531 | 2103 | 2.38 / 67.51 | 9 | 32 |
3 | 13 | 1914.04 | 20 | 14.88 | 3401 | 1012 | 3.40 / 68.52 | 4 | 36 |
4 | 13 | 1404.52 | 20 | 14.93 | 2650 | 791 | 4.19 / 69.31 | 4 | 42 |
5 | 13 | 850.28 | 20 | 15.04 | 1799 | 541 | 4.73 / 69.85 | 4 | 47 |
6 | 13 | 193.96 | 20 | 15.22 | 710 | 216 | 4.94 / 70.07 | 5 | 44 |
7 | 8 | 0.00 | 400 | 15.21 | 327 | 1989 | 6.93 / 72.06 | 5 | 52 |
Average= | 6.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 35 | 15.20 | 489 | 260 | 0.26 / 58.59 | 5 | 10 |
2 | 7 | 2008.28 | 40 | 14.90 | 3535 | 2107 | 2.37 / 60.70 | 10 | 32 |
3 | 13 | 1814.24 | 20 | 14.91 | 3264 | 973 | 3.34 / 61.67 | 4 | 36 |
4 | 13 | 1292.28 | 20 | 14.96 | 2478 | 741 | 4.08 / 62.42 | 4 | 43 |
5 | 13 | 648.72 | 20 | 15.10 | 1474 | 445 | 4.53 / 62.86 | 4 | 47 |
6 | 13 | 218.32 | 20 | 15.22 | 746 | 227 | 4.75 / 63.09 | 5 | 46 |
7 | 8 | -0.04 | 400 | 15.21 | 335 | 2038 | 6.79 / 65.13 | 5 | 57 |
Average= | 5.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 35 | 15.20 | 479 | 255 | 0.25 / 51.82 | 5 | 9 |
2 | 7 | 2003.32 | 40 | 14.91 | 3525 | 2102 | 2.36 / 53.92 | 9 | 32 |
3 | 13 | 1806.04 | 20 | 14.91 | 3240 | 966 | 3.32 / 54.88 | 4 | 37 |
4 | 13 | 1294.52 | 20 | 14.96 | 2479 | 742 | 4.07 / 55.63 | 4 | 43 |
5 | 13 | 845.60 | 20 | 15.04 | 1781 | 536 | 4.60 / 56.16 | 4 | 47 |
6 | 13 | 171.24 | 20 | 15.23 | 658 | 200 | 4.80 / 56.36 | 5 | 43 |
7 | 8 | -0.04 | 400 | 15.21 | 324 | 1971 | 6.77 / 58.33 | 5 | 60 |
Average= | 5.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 35 | 15.18 | 523 | 278 | 0.28 / 45.04 | 5 | 9 |
2 | 7 | 2003.20 | 40 | 14.91 | 3536 | 2109 | 2.39 / 47.15 | 20 | 32 |
3 | 13 | 1906.08 | 20 | 14.91 | 3394 | 1012 | 3.40 / 48.16 | 4 | 35 |
4 | 13 | 1268.88 | 20 | 14.97 | 2451 | 734 | 4.13 / 48.90 | 4 | 43 |
5 | 13 | 732.24 | 20 | 15.08 | 1611 | 486 | 4.62 / 49.38 | 4 | 47 |
6 | 13 | 192.24 | 20 | 15.23 | 701 | 214 | 4.83 / 49.59 | 5 | 44 |
7 | 8 | -0.16 | 400 | 15.22 | 323 | 1966 | 6.80 / 51.56 | 5 | 68 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 35 | 15.19 | 533 | 283 | 0.28 / 38.01 | 5 | 9 |
2 | 7 | 2011.72 | 40 | 14.92 | 3526 | 2104 | 2.39 / 40.11 | 21 | 32 |
3 | 13 | 1915.36 | 20 | 14.90 | 3398 | 1013 | 3.40 / 41.12 | 4 | 35 |
4 | 13 | 1484.48 | 20 | 14.93 | 2760 | 824 | 4.22 / 41.95 | 4 | 41 |
5 | 13 | 819.28 | 20 | 15.06 | 1742 | 525 | 4.75 / 42.47 | 4 | 46 |
6 | 13 | 164.36 | 20 | 15.24 | 648 | 198 | 4.95 / 42.67 | 5 | 42 |
7 | 8 | -0.08 | 400 | 15.21 | 344 | 2093 | 7.04 / 44.76 | 5 | 73 |
Average= | 5.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 34 | 15.18 | 509 | 263 | 0.26 / 31.02 | 5 | 9 |
2 | 3 | 1033.52 | 1 | 15.25 | 2094 | 32 | 0.29 / 31.05 | 5 | 32 |
3 | 7 | 2006.08 | 40 | 14.92 | 3525 | 2104 | 2.40 / 33.15 | 32 | 31 |
4 | 13 | 1917.68 | 20 | 14.91 | 3384 | 1009 | 3.41 / 34.16 | 4 | 35 |
5 | 13 | 1347.92 | 20 | 14.96 | 2557 | 765 | 4.17 / 34.93 | 4 | 42 |
6 | 13 | 692.36 | 20 | 15.10 | 1531 | 462 | 4.63 / 35.39 | 5 | 46 |
7 | 13 | 244.52 | 20 | 15.21 | 787 | 239 | 4.87 / 35.63 | 5 | 45 |
8 | 8 | 0.04 | 400 | 15.21 | 344 | 2093 | 6.97 / 37.72 | 5 | 61 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 31 | 15.17 | 524 | 246 | 0.25 / 24.08 | 5 | 7 |
2 | 10 | 1004.48 | 3 | 15.19 | 2040 | 93 | 0.34 / 24.18 | 5 | 23 |
3 | 7 | 2005.04 | 40 | 14.92 | 3522 | 2102 | 2.44 / 26.28 | 23 | 32 |
4 | 13 | 1906.16 | 20 | 14.91 | 3375 | 1006 | 3.45 / 27.28 | 4 | 35 |
5 | 13 | 1368.68 | 20 | 14.95 | 2591 | 775 | 4.22 / 28.06 | 4 | 42 |
6 | 13 | 708.28 | 20 | 15.09 | 1553 | 469 | 4.69 / 28.53 | 4 | 46 |
7 | 13 | 154.68 | 20 | 15.24 | 623 | 190 | 4.88 / 28.72 | 5 | 43 |
8 | 8 | 0.04 | 400 | 15.21 | 335 | 2038 | 6.92 / 30.76 | 5 | 56 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 34 | 15.18 | 517 | 267 | 0.27 / 18.03 | 5 | 7 |
2 | 7 | 1509.76 | 40 | 15.08 | 2777 | 1675 | 1.94 / 19.70 | 7 | 30 |
3 | 13 | 1441.76 | 20 | 15.06 | 2670 | 804 | 2.75 / 20.51 | 4 | 33 |
4 | 13 | 1131.12 | 20 | 15.07 | 2197 | 662 | 3.41 / 21.17 | 4 | 38 |
5 | 13 | 511.24 | 20 | 15.17 | 1230 | 373 | 3.78 / 21.54 | 5 | 41 |
6 | 13 | 81.60 | 20 | 15.28 | 486 | 149 | 3.93 / 21.69 | 5 | 37 |
7 | 8 | 0.16 | 400 | 15.21 | 353 | 2148 | 6.08 / 23.84 | 5 | 62 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 33 | 15.17 | 504 | 252 | 0.25 / 11.99 | 5 | 8 |
2 | 7 | 1515.64 | 40 | 15.08 | 2778 | 1676 | 1.93 / 13.67 | 12 | 29 |
3 | 13 | 1433.60 | 20 | 15.06 | 2656 | 800 | 2.73 / 14.47 | 4 | 32 |
4 | 13 | 1337.24 | 20 | 15.02 | 2511 | 754 | 3.48 / 15.22 | 4 | 35 |
5 | 13 | 551.20 | 20 | 15.16 | 1296 | 393 | 3.88 / 15.62 | 5 | 41 |
6 | 13 | 57.68 | 20 | 15.28 | 435 | 133 | 4.01 / 15.75 | 5 | 31 |
7 | 8 | 0.04 | 400 | 15.22 | 330 | 2009 | 6.02 / 17.76 | 5 | 92 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 31 | 15.19 | 507 | 239 | 0.24 / 5.95 | 5 | 8 |
2 | 10 | 1022.76 | 3 | 15.20 | 2033 | 93 | 0.33 / 6.04 | 5 | 26 |
3 | 7 | 1512.96 | 40 | 15.07 | 2782 | 1677 | 2.01 / 7.72 | 25 | 34 |
4 | 13 | 1437.00 | 20 | 15.05 | 2666 | 802 | 2.81 / 8.52 | 4 | 36 |
5 | 13 | 1244.56 | 20 | 15.03 | 2368 | 712 | 3.52 / 9.23 | 4 | 39 |
6 | 13 | 565.80 | 20 | 15.14 | 1318 | 399 | 3.92 / 9.63 | 4 | 44 |
7 | 13 | 61.28 | 20 | 15.27 | 446 | 136 | 4.06 / 9.76 | 5 | 36 |
8 | 8 | -0.04 | 400 | 15.21 | 325 | 1977 | 6.04 / 11.74 | 5 | 75 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 31 | 15.38 | 445 | 212 | 0.21 / 2.00 | 5 | 7 |
2 | 3 | 1085.40 | 2 | 15.25 | 2113 | 64 | 0.28 / 2.06 | 5 | 31 |
3 | 7 | 1023.56 | 40 | 15.16 | 2020 | 1225 | 1.50 / 3.29 | 31 | 38 |
4 | 13 | 498.56 | 20 | 15.23 | 1202 | 366 | 1.87 / 3.66 | 5 | 44 |
5 | 13 | 46.20 | 20 | 15.31 | 410 | 126 | 1.99 / 3.78 | 5 | 31 |
6 | 8 | 0.00 | 383 | 15.24 | 330 | 1926 | 3.92 / 5.71 | 5 | 137 |
Average= | 2.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 122.56 | 30 | 15.54 | 480 | 224 | 0.22 / 0.22 | 5 | 8 |
2 | 7 | 133.96 | 40 | 15.52 | 490 | 304 | 0.53 / 0.53 | 8 | 10 |
3 | 13 | 92.64 | 20 | 15.50 | 420 | 130 | 0.66 / 0.66 | 5 | 10 |
4 | 13 | 24.68 | 20 | 15.49 | 318 | 99 | 0.76 / 0.76 | 5 | 14 |
5 | 8 | 0.16 | 248 | 15.45 | 269 | 1031 | 1.79 / 1.79 | 5 | 134 |
Average= | 1.79 (KJ/cycle) |