SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 38 | 14.85 | 500 | 282 | 0.28 / 1122.79 | 6 | 50 |
2 | 7 | 2015.72 | 40 | 14.46 | 3359 | 1943 | 2.22 / 1124.74 | 50 | 64 |
3 | 13 | 1929.44 | 20 | 14.45 | 3221 | 931 | 3.16 / 1125.67 | 5 | 67 |
4 | 13 | 1511.72 | 20 | 14.44 | 2645 | 764 | 3.92 / 1126.43 | 5 | 77 |
5 | 13 | 977.56 | 20 | 14.55 | 1850 | 538 | 4.46 / 1126.97 | 5 | 90 |
6 | 13 | 436.76 | 20 | 14.74 | 1016 | 300 | 4.76 / 1127.27 | 6 | 96 |
7 | 8 | -0.12 | 259 | 14.85 | 341 | 1312 | 6.07 / 1128.58 | 6 | 137 |
Average= | 12.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 38 | 14.84 | 507 | 286 | 0.29 / 1116.56 | 6 | 55 |
2 | 7 | 2006.40 | 41 | 14.47 | 3332 | 1977 | 2.26 / 1118.54 | 55 | 65 |
3 | 13 | 1921.68 | 20 | 14.45 | 3212 | 928 | 3.19 / 1119.46 | 5 | 68 |
4 | 13 | 1723.20 | 20 | 14.39 | 2945 | 848 | 4.04 / 1120.31 | 5 | 76 |
5 | 13 | 1055.96 | 20 | 14.54 | 1964 | 571 | 4.61 / 1120.88 | 5 | 89 |
6 | 13 | 392.88 | 20 | 14.76 | 943 | 278 | 4.89 / 1121.16 | 6 | 95 |
7 | 8 | 0.40 | 261 | 14.85 | 348 | 1349 | 6.24 / 1122.51 | 6 | 132 |
Average= | 12.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 38 | 14.83 | 509 | 287 | 0.29 / 1110.51 | 6 | 58 |
2 | 7 | 2015.88 | 40 | 14.46 | 3350 | 1938 | 2.22 / 1112.45 | 58 | 64 |
3 | 13 | 1933.60 | 20 | 14.44 | 3226 | 932 | 3.16 / 1113.38 | 5 | 67 |
4 | 13 | 1619.88 | 20 | 14.42 | 2804 | 809 | 3.96 / 1114.19 | 5 | 76 |
5 | 13 | 968.00 | 20 | 14.57 | 1822 | 531 | 4.50 / 1114.72 | 5 | 90 |
6 | 13 | 312.84 | 20 | 14.80 | 822 | 243 | 4.74 / 1114.96 | 6 | 93 |
7 | 8 | 0.12 | 259 | 14.85 | 341 | 1312 | 6.05 / 1116.27 | 6 | 129 |
Average= | 12.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 37 | 14.84 | 496 | 272 | 0.27 / 1104.39 | 6 | 58 |
2 | 3 | 1035.72 | 1 | 14.88 | 1973 | 29 | 0.30 / 1104.42 | 5 | 40 |
3 | 7 | 2005.12 | 40 | 14.47 | 3344 | 1936 | 2.24 / 1106.36 | 40 | 65 |
4 | 13 | 1921.84 | 20 | 14.45 | 3212 | 928 | 3.17 / 1107.29 | 5 | 71 |
5 | 13 | 1603.36 | 20 | 14.44 | 2776 | 802 | 3.97 / 1108.09 | 5 | 77 |
6 | 13 | 965.88 | 20 | 14.57 | 1822 | 531 | 4.50 / 1108.62 | 5 | 92 |
7 | 13 | 224.92 | 20 | 14.84 | 702 | 208 | 4.71 / 1108.83 | 6 | 92 |
8 | 8 | 0.24 | 267 | 14.85 | 352 | 1396 | 6.10 / 1110.22 | 6 | 135 |
Average= | 13.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 38 | 14.84 | 507 | 286 | 0.29 / 1098.36 | 6 | 59 |
2 | 7 | 2007.08 | 41 | 14.47 | 3333 | 1977 | 2.26 / 1100.34 | 59 | 67 |
3 | 13 | 1925.12 | 20 | 14.45 | 3231 | 934 | 3.20 / 1101.27 | 5 | 71 |
4 | 13 | 1617.64 | 20 | 14.43 | 2791 | 805 | 4.00 / 1102.08 | 5 | 78 |
5 | 13 | 972.28 | 20 | 14.57 | 1832 | 534 | 4.54 / 1102.61 | 5 | 93 |
6 | 13 | 121.24 | 20 | 14.88 | 547 | 163 | 4.70 / 1102.77 | 6 | 91 |
7 | 8 | 0.00 | 263 | 14.86 | 345 | 1348 | 6.05 / 1104.12 | 6 | 133 |
Average= | 13.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 38 | 14.83 | 514 | 290 | 0.29 / 1092.23 | 6 | 59 |
2 | 7 | 2007.00 | 41 | 14.46 | 3344 | 1983 | 2.27 / 1094.22 | 59 | 66 |
3 | 13 | 1925.24 | 20 | 14.46 | 3227 | 933 | 3.21 / 1095.15 | 5 | 70 |
4 | 13 | 1511.12 | 20 | 14.45 | 2641 | 763 | 3.97 / 1095.91 | 5 | 80 |
5 | 13 | 1081.44 | 20 | 14.52 | 1986 | 577 | 4.55 / 1096.49 | 5 | 90 |
6 | 13 | 420.20 | 20 | 14.76 | 985 | 291 | 4.84 / 1096.78 | 5 | 95 |
7 | 8 | 0.12 | 257 | 14.85 | 339 | 1294 | 6.13 / 1098.07 | 6 | 131 |
Average= | 13.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 38 | 14.83 | 514 | 290 | 0.29 / 1086.01 | 6 | 60 |
2 | 7 | 2016.64 | 40 | 14.47 | 3359 | 1944 | 2.23 / 1087.95 | 60 | 64 |
3 | 13 | 1928.20 | 20 | 14.45 | 3217 | 930 | 3.16 / 1088.88 | 5 | 67 |
4 | 13 | 1612.56 | 20 | 14.44 | 2781 | 803 | 3.97 / 1089.68 | 5 | 76 |
5 | 13 | 1053.44 | 20 | 14.54 | 1960 | 570 | 4.54 / 1090.25 | 5 | 87 |
6 | 13 | 396.20 | 20 | 14.76 | 960 | 283 | 4.82 / 1090.54 | 5 | 97 |
7 | 13 | 31.64 | 20 | 14.89 | 417 | 124 | 4.94 / 1090.66 | 6 | 89 |
8 | 8 | -0.12 | 244 | 14.84 | 354 | 1282 | 6.23 / 1091.94 | 6 | 135 |
Average= | 13.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 38 | 14.84 | 501 | 283 | 0.28 / 1079.92 | 6 | 60 |
2 | 7 | 2016.72 | 40 | 14.45 | 3358 | 1941 | 2.22 / 1081.86 | 6 | 64 |
3 | 13 | 1934.52 | 20 | 14.44 | 3256 | 940 | 3.16 / 1082.80 | 5 | 69 |
4 | 13 | 1528.68 | 20 | 14.45 | 2669 | 771 | 3.94 / 1083.58 | 5 | 78 |
5 | 13 | 887.20 | 20 | 14.60 | 1706 | 498 | 4.43 / 1084.07 | 5 | 90 |
6 | 13 | 341.48 | 20 | 14.79 | 870 | 257 | 4.69 / 1084.33 | 6 | 94 |
7 | 8 | 0.28 | 270 | 14.85 | 346 | 1387 | 6.08 / 1085.72 | 6 | 135 |
Average= | 13.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 38 | 14.84 | 493 | 278 | 0.28 / 1073.88 | 6 | 56 |
2 | 7 | 2015.64 | 40 | 14.47 | 3366 | 1948 | 2.23 / 1075.83 | 56 | 67 |
3 | 13 | 1934.08 | 20 | 14.44 | 3238 | 935 | 3.16 / 1076.77 | 5 | 70 |
4 | 13 | 1346.72 | 20 | 14.50 | 2394 | 694 | 3.86 / 1077.46 | 5 | 84 |
5 | 13 | 1039.20 | 20 | 14.54 | 1941 | 564 | 4.42 / 1078.03 | 5 | 90 |
6 | 13 | 277.00 | 20 | 14.81 | 776 | 230 | 4.65 / 1078.25 | 6 | 95 |
7 | 8 | 0.32 | 268 | 14.85 | 348 | 1385 | 6.03 / 1079.64 | 6 | 137 |
Average= | 13.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 38 | 14.83 | 500 | 282 | 0.28 / 1067.69 | 6 | 58 |
2 | 7 | 2010.40 | 41 | 14.47 | 3344 | 1984 | 2.27 / 1069.67 | 58 | 67 |
3 | 13 | 1931.52 | 20 | 14.45 | 3230 | 933 | 3.20 / 1070.61 | 5 | 72 |
4 | 13 | 1615.76 | 20 | 14.43 | 2796 | 807 | 4.01 / 1071.41 | 5 | 79 |
5 | 13 | 967.88 | 20 | 14.57 | 1824 | 532 | 4.54 / 1071.94 | 5 | 91 |
6 | 13 | 412.88 | 20 | 14.76 | 970 | 286 | 4.82 / 1072.23 | 5 | 95 |
7 | 8 | 0.64 | 267 | 14.84 | 347 | 1375 | 6.20 / 1073.60 | 6 | 132 |
Average= | 13.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 38 | 14.84 | 511 | 288 | 0.29 / 1061.50 | 6 | 58 |
2 | 7 | 2009.16 | 40 | 14.48 | 3346 | 1938 | 2.23 / 1063.44 | 58 | 64 |
3 | 13 | 1920.32 | 20 | 14.47 | 3218 | 931 | 3.16 / 1064.37 | 5 | 68 |
4 | 13 | 1505.56 | 20 | 14.46 | 2639 | 763 | 3.92 / 1065.14 | 5 | 80 |
5 | 13 | 993.32 | 20 | 14.56 | 1860 | 542 | 4.46 / 1065.68 | 5 | 88 |
6 | 13 | 565.92 | 20 | 14.70 | 1199 | 353 | 4.81 / 1066.03 | 5 | 96 |
7 | 13 | 37.36 | 20 | 14.89 | 411 | 122 | 4.94 / 1066.15 | 6 | 87 |
8 | 8 | 0.32 | 249 | 14.84 | 339 | 1253 | 6.19 / 1067.41 | 6 | 133 |
Average= | 13.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 38 | 14.84 | 508 | 286 | 0.29 / 1055.36 | 6 | 59 |
2 | 7 | 2014.68 | 40 | 14.48 | 3352 | 1941 | 2.23 / 1057.30 | 59 | 65 |
3 | 13 | 1929.32 | 20 | 14.45 | 3246 | 938 | 3.17 / 1058.24 | 5 | 70 |
4 | 13 | 1725.64 | 20 | 14.41 | 2950 | 850 | 4.02 / 1059.09 | 5 | 76 |
5 | 13 | 864.04 | 20 | 14.62 | 1666 | 487 | 4.50 / 1059.58 | 5 | 91 |
6 | 13 | 320.28 | 20 | 14.81 | 839 | 249 | 4.75 / 1059.82 | 6 | 95 |
7 | 8 | -0.04 | 267 | 14.85 | 351 | 1392 | 6.14 / 1061.22 | 6 | 137 |
Average= | 13.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 38 | 14.83 | 518 | 292 | 0.29 / 1049.27 | 6 | 59 |
2 | 7 | 2010.60 | 41 | 14.48 | 3342 | 1984 | 2.28 / 1051.25 | 59 | 66 |
3 | 13 | 1924.52 | 20 | 14.44 | 3239 | 935 | 3.21 / 1052.19 | 5 | 70 |
4 | 13 | 1612.60 | 20 | 14.43 | 2803 | 809 | 4.02 / 1053.00 | 5 | 77 |
5 | 13 | 956.40 | 20 | 14.58 | 1809 | 528 | 4.55 / 1053.52 | 5 | 90 |
6 | 13 | 208.92 | 20 | 14.85 | 676 | 201 | 4.75 / 1053.73 | 6 | 92 |
7 | 8 | 0.44 | 263 | 14.85 | 345 | 1347 | 6.10 / 1055.07 | 6 | 139 |
Average= | 13.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 38 | 14.84 | 496 | 280 | 0.28 / 1043.03 | 6 | 57 |
2 | 3 | 1022.40 | 1 | 14.89 | 1989 | 30 | 0.31 / 1043.06 | 5 | 23 |
3 | 7 | 2004.32 | 40 | 14.48 | 3343 | 1936 | 2.25 / 1045.00 | 23 | 63 |
4 | 13 | 1927.64 | 20 | 14.45 | 3254 | 940 | 3.19 / 1045.94 | 5 | 70 |
5 | 13 | 1516.76 | 20 | 14.46 | 2659 | 769 | 3.95 / 1046.71 | 5 | 78 |
6 | 13 | 1085.92 | 20 | 14.54 | 2002 | 582 | 4.54 / 1047.29 | 5 | 89 |
7 | 13 | 426.00 | 20 | 14.76 | 998 | 295 | 4.83 / 1047.59 | 5 | 96 |
8 | 8 | 0.08 | 266 | 14.85 | 352 | 1390 | 6.22 / 1048.98 | 6 | 135 |
Average= | 13.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 37 | 14.83 | 507 | 278 | 0.28 / 1037.01 | 6 | 56 |
2 | 7 | 2006.00 | 41 | 14.47 | 3337 | 1980 | 2.26 / 1038.99 | 56 | 64 |
3 | 13 | 1925.48 | 20 | 14.46 | 3237 | 936 | 3.19 / 1039.92 | 5 | 68 |
4 | 13 | 1516.72 | 20 | 14.46 | 2646 | 765 | 3.96 / 1040.69 | 5 | 78 |
5 | 13 | 886.60 | 20 | 14.60 | 1704 | 498 | 4.46 / 1041.19 | 5 | 93 |
6 | 13 | 253.96 | 20 | 14.82 | 741 | 220 | 4.68 / 1041.41 | 6 | 91 |
7 | 8 | 0.04 | 263 | 14.85 | 345 | 1347 | 6.02 / 1042.75 | 6 | 134 |
Average= | 14.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 37 | 14.83 | 521 | 286 | 0.29 / 1030.89 | 6 | 56 |
2 | 7 | 2015.16 | 41 | 14.47 | 3345 | 1984 | 2.27 / 1032.88 | 56 | 65 |
3 | 13 | 1928.28 | 20 | 14.45 | 3248 | 939 | 3.21 / 1033.81 | 5 | 71 |
4 | 13 | 1516.52 | 20 | 14.46 | 2657 | 768 | 3.98 / 1034.58 | 5 | 79 |
5 | 13 | 1086.08 | 20 | 14.53 | 2006 | 583 | 4.56 / 1035.17 | 5 | 89 |
6 | 13 | 314.20 | 20 | 14.80 | 832 | 246 | 4.81 / 1035.41 | 5 | 98 |
7 | 8 | 0.08 | 259 | 14.85 | 343 | 1319 | 6.13 / 1036.73 | 6 | 136 |
Average= | 14.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 37 | 14.84 | 512 | 281 | 0.28 / 1024.62 | 6 | 53 |
2 | 7 | 2006.44 | 40 | 14.48 | 3357 | 1944 | 2.23 / 1026.56 | 53 | 63 |
3 | 13 | 1928.36 | 20 | 14.46 | 3239 | 937 | 3.16 / 1027.50 | 5 | 68 |
4 | 13 | 1623.36 | 20 | 14.44 | 2815 | 813 | 3.98 / 1028.31 | 5 | 75 |
5 | 13 | 984.44 | 20 | 14.57 | 1870 | 545 | 4.52 / 1028.86 | 5 | 90 |
6 | 13 | 551.00 | 20 | 14.70 | 1205 | 354 | 4.87 / 1029.21 | 5 | 97 |
7 | 8 | 0.20 | 266 | 14.84 | 353 | 1393 | 6.27 / 1030.60 | 6 | 137 |
Average= | 14.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 37 | 14.85 | 495 | 272 | 0.27 / 1018.48 | 6 | 50 |
2 | 7 | 2013.20 | 40 | 14.48 | 3341 | 1935 | 2.21 / 1020.41 | 50 | 64 |
3 | 13 | 1927.28 | 20 | 14.47 | 3227 | 934 | 3.14 / 1021.35 | 5 | 68 |
4 | 13 | 1515.96 | 20 | 14.47 | 2645 | 765 | 3.91 / 1022.11 | 5 | 78 |
5 | 13 | 1090.24 | 20 | 14.53 | 2010 | 584 | 4.49 / 1022.70 | 5 | 88 |
6 | 13 | 446.40 | 20 | 14.75 | 1026 | 303 | 4.79 / 1023.00 | 5 | 96 |
7 | 13 | 20.36 | 20 | 14.91 | 390 | 116 | 4.91 / 1023.11 | 6 | 88 |
8 | 8 | 0.36 | 240 | 14.85 | 343 | 1222 | 6.13 / 1024.34 | 6 | 129 |
Average= | 14.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 37 | 14.84 | 513 | 282 | 0.28 / 1012.20 | 6 | 55 |
2 | 7 | 2016.28 | 40 | 14.49 | 3340 | 1936 | 2.22 / 1014.13 | 55 | 63 |
3 | 13 | 1935.24 | 20 | 14.47 | 3239 | 937 | 3.15 / 1015.07 | 5 | 68 |
4 | 13 | 1626.08 | 20 | 14.45 | 2816 | 814 | 3.97 / 1015.88 | 5 | 77 |
5 | 13 | 1092.60 | 20 | 14.54 | 2025 | 589 | 4.56 / 1016.47 | 5 | 88 |
6 | 13 | 658.28 | 20 | 14.67 | 1359 | 399 | 4.96 / 1016.87 | 5 | 96 |
7 | 13 | 16.44 | 20 | 14.91 | 381 | 114 | 5.07 / 1016.99 | 6 | 89 |
8 | 8 | -0.08 | 240 | 14.85 | 342 | 1219 | 6.29 / 1018.20 | 6 | 129 |
Average= | 14.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 37 | 14.85 | 506 | 278 | 0.28 / 1006.01 | 6 | 48 |
2 | 7 | 2006.16 | 40 | 14.49 | 3353 | 1943 | 2.22 / 1007.95 | 48 | 64 |
3 | 13 | 1920.56 | 20 | 14.46 | 3230 | 934 | 3.16 / 1008.89 | 5 | 69 |
4 | 13 | 1607.56 | 20 | 14.45 | 2785 | 805 | 3.96 / 1009.69 | 5 | 78 |
5 | 13 | 1072.04 | 20 | 14.54 | 1990 | 579 | 4.54 / 1010.27 | 5 | 89 |
6 | 13 | 413.48 | 20 | 14.76 | 977 | 288 | 4.83 / 1010.56 | 5 | 96 |
7 | 8 | 0.24 | 261 | 14.85 | 350 | 1357 | 6.18 / 1011.92 | 6 | 134 |
Average= | 14.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 36 | 14.84 | 508 | 271 | 0.27 / 999.72 | 6 | 51 |
2 | 3 | 1028.80 | 1 | 14.90 | 1941 | 29 | 0.30 / 999.75 | 5 | 38 |
3 | 7 | 2011.28 | 40 | 14.49 | 3350 | 1942 | 2.24 / 1001.69 | 38 | 64 |
4 | 13 | 1926.64 | 20 | 14.47 | 3238 | 937 | 3.18 / 1002.62 | 5 | 69 |
5 | 13 | 1620.72 | 20 | 14.45 | 2809 | 812 | 3.99 / 1003.44 | 5 | 76 |
6 | 13 | 1180.00 | 20 | 14.51 | 2162 | 627 | 4.62 / 1004.06 | 5 | 85 |
7 | 13 | 417.80 | 20 | 14.76 | 996 | 294 | 4.91 / 1004.36 | 6 | 95 |
8 | 8 | 0.00 | 263 | 14.85 | 352 | 1375 | 6.29 / 1005.73 | 6 | 135 |
Average= | 14.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 36 | 14.84 | 509 | 272 | 0.27 / 993.56 | 6 | 44 |
2 | 3 | 1022.76 | 1 | 14.91 | 1956 | 29 | 0.30 / 993.59 | 5 | 22 |
3 | 7 | 2004.08 | 40 | 14.48 | 3338 | 1933 | 2.23 / 995.53 | 22 | 66 |
4 | 13 | 1908.04 | 20 | 14.47 | 3209 | 929 | 3.16 / 996.46 | 5 | 71 |
5 | 13 | 1599.88 | 20 | 14.45 | 2765 | 799 | 3.96 / 997.26 | 5 | 76 |
6 | 13 | 945.08 | 20 | 14.59 | 1794 | 523 | 4.49 / 997.78 | 5 | 90 |
7 | 13 | 408.12 | 20 | 14.77 | 970 | 287 | 4.77 / 998.07 | 6 | 96 |
8 | 8 | 0.04 | 267 | 14.85 | 348 | 1380 | 6.15 / 999.44 | 6 | 136 |
Average= | 14.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 36 | 14.85 | 513 | 274 | 0.27 / 987.48 | 6 | 42 |
2 | 7 | 2016.48 | 40 | 14.50 | 3350 | 1943 | 2.22 / 989.42 | 42 | 65 |
3 | 13 | 1934.32 | 20 | 14.47 | 3237 | 937 | 3.15 / 990.36 | 5 | 68 |
4 | 13 | 1522.56 | 20 | 14.47 | 2660 | 770 | 3.92 / 991.13 | 5 | 79 |
5 | 13 | 997.48 | 20 | 14.57 | 1875 | 546 | 4.47 / 991.68 | 5 | 90 |
6 | 13 | 338.92 | 20 | 14.79 | 868 | 257 | 4.73 / 991.93 | 6 | 99 |
7 | 8 | 0.20 | 267 | 14.85 | 343 | 1360 | 6.09 / 993.29 | 6 | 132 |
Average= | 15.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 36 | 14.84 | 509 | 272 | 0.27 / 981.35 | 6 | 44 |
2 | 7 | 2006.88 | 40 | 14.49 | 3353 | 1943 | 2.22 / 983.29 | 44 | 64 |
3 | 13 | 1924.48 | 20 | 14.47 | 3229 | 934 | 3.15 / 984.23 | 5 | 72 |
4 | 13 | 1622.84 | 20 | 14.45 | 2802 | 810 | 3.96 / 985.04 | 5 | 79 |
5 | 13 | 979.00 | 20 | 14.57 | 1846 | 538 | 4.50 / 985.58 | 5 | 92 |
6 | 13 | 352.48 | 20 | 14.79 | 891 | 264 | 4.76 / 985.84 | 6 | 96 |
7 | 13 | 23.40 | 20 | 14.90 | 403 | 120 | 4.88 / 985.96 | 6 | 93 |
8 | 8 | 0.16 | 244 | 14.85 | 344 | 1246 | 6.13 / 987.21 | 6 | 131 |
Average= | 15.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 36 | 14.84 | 493 | 263 | 0.26 / 975.32 | 6 | 46 |
2 | 7 | 2012.68 | 40 | 14.50 | 3337 | 1935 | 2.20 / 977.25 | 46 | 65 |
3 | 13 | 1928.60 | 20 | 14.48 | 3241 | 939 | 3.14 / 978.19 | 5 | 68 |
4 | 13 | 1423.72 | 20 | 14.49 | 2501 | 725 | 3.86 / 978.92 | 5 | 81 |
5 | 13 | 1012.32 | 20 | 14.57 | 1887 | 550 | 4.41 / 979.47 | 5 | 90 |
6 | 13 | 469.16 | 20 | 14.74 | 1052 | 310 | 4.72 / 979.78 | 5 | 94 |
7 | 8 | 0.12 | 257 | 14.85 | 341 | 1301 | 6.02 / 981.08 | 6 | 132 |
Average= | 15.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 37 | 14.85 | 486 | 267 | 0.27 / 969.21 | 6 | 48 |
2 | 3 | 967.12 | -1 | 15.27 | 3 | 0 | 0.00 / 969.21 | 6 | 48 |
3 | 7 | 2012.88 | 40 | 14.50 | 3337 | 1935 | 2.20 / 971.14 | 48 | 65 |
4 | 13 | 1916.28 | 20 | 14.48 | 3220 | 933 | 3.14 / 972.07 | 5 | 69 |
5 | 13 | 1502.08 | 20 | 14.49 | 2622 | 760 | 3.89 / 972.83 | 5 | 78 |
6 | 13 | 1169.64 | 20 | 14.51 | 2133 | 619 | 4.51 / 973.45 | 5 | 87 |
7 | 13 | 380.92 | 20 | 14.78 | 931 | 275 | 4.79 / 973.73 | 5 | 97 |
8 | 8 | 0.12 | 266 | 14.85 | 336 | 1327 | 6.12 / 975.05 | 6 | 130 |
Average= | 15.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 36 | 14.84 | 489 | 261 | 0.26 / 963.07 | 6 | 57 |
2 | 3 | 1030.12 | 1 | 14.89 | 1971 | 29 | 0.29 / 963.10 | 5 | 34 |
3 | 7 | 2008.00 | 40 | 14.51 | 3340 | 1939 | 2.23 / 965.04 | 34 | 69 |
4 | 13 | 1932.84 | 20 | 14.48 | 3230 | 935 | 3.16 / 965.97 | 5 | 72 |
5 | 13 | 1529.88 | 20 | 14.48 | 2662 | 771 | 3.94 / 966.74 | 5 | 82 |
6 | 13 | 897.28 | 20 | 14.61 | 1729 | 505 | 4.44 / 967.25 | 5 | 93 |
7 | 13 | 582.76 | 20 | 14.70 | 1237 | 364 | 4.80 / 967.61 | 5 | 97 |
8 | 8 | 0.24 | 261 | 14.85 | 342 | 1326 | 6.13 / 968.94 | 6 | 130 |
Average= | 15.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 36 | 14.83 | 505 | 270 | 0.27 / 957.06 | 6 | 53 |
2 | 7 | 2008.56 | 40 | 14.50 | 3347 | 1941 | 2.21 / 959.00 | 53 | 70 |
3 | 13 | 1919.76 | 20 | 14.48 | 3228 | 935 | 3.15 / 959.93 | 5 | 73 |
4 | 13 | 1409.68 | 20 | 14.49 | 2498 | 724 | 3.87 / 960.66 | 5 | 87 |
5 | 13 | 989.08 | 20 | 14.58 | 1864 | 544 | 4.41 / 961.20 | 5 | 93 |
6 | 13 | 320.92 | 20 | 14.80 | 840 | 249 | 4.66 / 961.45 | 5 | 100 |
7 | 8 | 0.12 | 265 | 14.84 | 346 | 1361 | 6.02 / 962.81 | 6 | 131 |
Average= | 15.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 37 | 14.83 | 507 | 278 | 0.28 / 951.03 | 6 | 51 |
2 | 7 | 2005.60 | 41 | 14.50 | 3351 | 1992 | 2.27 / 953.03 | 51 | 66 |
3 | 13 | 1920.40 | 20 | 14.48 | 3227 | 935 | 3.20 / 953.96 | 5 | 72 |
4 | 13 | 1494.84 | 20 | 14.48 | 2613 | 757 | 3.96 / 954.72 | 5 | 79 |
5 | 13 | 844.76 | 20 | 14.63 | 1642 | 480 | 4.44 / 955.20 | 5 | 94 |
6 | 13 | 405.72 | 20 | 14.77 | 966 | 285 | 4.73 / 955.48 | 5 | 100 |
7 | 13 | 13.92 | 20 | 14.90 | 394 | 117 | 4.84 / 955.60 | 6 | 95 |
8 | 8 | 0.04 | 227 | 14.84 | 352 | 1186 | 6.03 / 956.79 | 6 | 136 |
Average= | 15.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 37 | 14.82 | 525 | 288 | 0.29 / 944.94 | 6 | 54 |
2 | 7 | 2006.64 | 40 | 14.51 | 3344 | 1941 | 2.23 / 946.88 | 54 | 65 |
3 | 13 | 1930.28 | 20 | 14.49 | 3240 | 939 | 3.17 / 947.82 | 5 | 68 |
4 | 13 | 1510.32 | 20 | 14.48 | 2654 | 769 | 3.94 / 948.59 | 5 | 78 |
5 | 13 | 880.56 | 20 | 14.62 | 1694 | 495 | 4.43 / 949.08 | 5 | 93 |
6 | 13 | 346.92 | 20 | 14.79 | 883 | 261 | 4.69 / 949.34 | 5 | 100 |
7 | 8 | 0.24 | 268 | 14.84 | 355 | 1412 | 6.10 / 950.76 | 6 | 144 |
Average= | 16.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 37 | 14.83 | 505 | 277 | 0.28 / 938.83 | 6 | 51 |
2 | 7 | 2003.52 | 40 | 14.50 | 3326 | 1929 | 2.21 / 940.76 | 51 | 66 |
3 | 13 | 1912.64 | 20 | 14.48 | 3200 | 927 | 3.13 / 941.69 | 5 | 71 |
4 | 13 | 1498.60 | 20 | 14.49 | 2622 | 760 | 3.89 / 942.45 | 5 | 80 |
5 | 13 | 861.32 | 20 | 14.62 | 1666 | 487 | 4.38 / 942.93 | 5 | 95 |
6 | 13 | 422.12 | 20 | 14.76 | 1000 | 295 | 4.68 / 943.23 | 5 | 103 |
7 | 8 | 0.32 | 267 | 14.84 | 359 | 1422 | 6.10 / 944.65 | 6 | 138 |
Average= | 16.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 36 | 14.82 | 504 | 269 | 0.27 / 932.44 | 6 | 55 |
2 | 3 | 1039.92 | 1 | 14.87 | 1983 | 29 | 0.30 / 932.47 | 5 | 45 |
3 | 7 | 2013.80 | 40 | 14.50 | 3355 | 1946 | 2.24 / 934.42 | 45 | 67 |
4 | 13 | 1923.08 | 20 | 14.48 | 3236 | 937 | 3.18 / 935.36 | 5 | 71 |
5 | 13 | 1607.48 | 20 | 14.46 | 2792 | 807 | 3.99 / 936.16 | 5 | 78 |
6 | 13 | 1141.96 | 20 | 14.53 | 2107 | 612 | 4.60 / 936.78 | 5 | 89 |
7 | 13 | 579.20 | 20 | 14.70 | 1241 | 365 | 4.97 / 937.14 | 5 | 98 |
8 | 8 | 0.24 | 268 | 14.84 | 355 | 1412 | 6.38 / 938.55 | 6 | 135 |
Average= | 16.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 38 | 14.83 | 512 | 289 | 0.29 / 926.24 | 6 | 53 |
2 | 3 | 950.96 | -1 | 15.27 | 3 | 0 | 0.00 / 926.24 | 6 | 53 |
3 | 7 | 2004.92 | 40 | 14.50 | 3350 | 1943 | 2.23 / 928.18 | 53 | 67 |
4 | 13 | 1918.20 | 20 | 14.47 | 3246 | 939 | 3.17 / 929.12 | 5 | 72 |
5 | 13 | 1492.64 | 20 | 14.49 | 2620 | 759 | 3.93 / 929.88 | 5 | 81 |
6 | 13 | 1056.44 | 20 | 14.55 | 1975 | 575 | 4.50 / 930.45 | 5 | 92 |
7 | 13 | 383.08 | 20 | 14.77 | 942 | 278 | 4.78 / 930.73 | 5 | 100 |
8 | 8 | -0.04 | 272 | 14.83 | 358 | 1444 | 6.23 / 932.18 | 6 | 129 |
Average= | 16.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 38 | 14.83 | 506 | 285 | 0.29 / 920.04 | 6 | 56 |
2 | 7 | 2007.24 | 40 | 14.51 | 3349 | 1944 | 2.23 / 921.99 | 12 | 64 |
3 | 13 | 1932.56 | 20 | 14.48 | 3235 | 937 | 3.17 / 922.92 | 5 | 70 |
4 | 13 | 1527.20 | 20 | 14.48 | 2660 | 770 | 3.94 / 923.69 | 5 | 81 |
5 | 13 | 1107.32 | 20 | 14.54 | 2038 | 593 | 4.53 / 924.29 | 5 | 91 |
6 | 13 | 457.16 | 20 | 14.75 | 1046 | 309 | 4.84 / 924.59 | 5 | 100 |
7 | 8 | 0.08 | 265 | 14.85 | 344 | 1354 | 6.19 / 925.95 | 6 | 130 |
Average= | 16.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 38 | 14.83 | 507 | 286 | 0.29 / 913.78 | 6 | 58 |
2 | 7 | 2008.80 | 40 | 14.51 | 3352 | 1946 | 2.23 / 915.73 | 58 | 66 |
3 | 13 | 1932.48 | 20 | 14.50 | 3243 | 940 | 3.17 / 916.67 | 5 | 70 |
4 | 13 | 1737.12 | 20 | 14.44 | 2977 | 860 | 4.03 / 917.53 | 5 | 75 |
5 | 13 | 971.04 | 20 | 14.60 | 1835 | 536 | 4.57 / 918.06 | 5 | 92 |
6 | 13 | 431.76 | 20 | 14.77 | 1008 | 298 | 4.87 / 918.36 | 5 | 100 |
7 | 8 | 0.28 | 268 | 14.85 | 351 | 1397 | 6.26 / 919.76 | 6 | 131 |
Average= | 17.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 38 | 14.83 | 511 | 288 | 0.29 / 907.63 | 6 | 61 |
2 | 7 | 2003.64 | 40 | 14.51 | 3342 | 1940 | 2.23 / 909.57 | 61 | 67 |
3 | 13 | 1921.36 | 20 | 14.49 | 3221 | 933 | 3.16 / 910.51 | 5 | 71 |
4 | 13 | 1617.92 | 20 | 14.47 | 2786 | 806 | 3.97 / 911.31 | 5 | 79 |
5 | 13 | 877.24 | 20 | 14.62 | 1694 | 495 | 4.46 / 911.81 | 5 | 95 |
6 | 13 | 453.96 | 20 | 14.75 | 1047 | 309 | 4.77 / 912.12 | 5 | 103 |
7 | 8 | 0.36 | 261 | 14.84 | 356 | 1379 | 6.15 / 913.50 | 6 | 129 |
Average= | 17.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 38 | 14.82 | 521 | 293 | 0.29 / 901.60 | 6 | 62 |
2 | 7 | 2014.92 | 40 | 14.51 | 3351 | 1945 | 2.24 / 903.54 | 7 | 66 |
3 | 13 | 1925.84 | 20 | 14.48 | 3249 | 941 | 3.18 / 904.48 | 5 | 69 |
4 | 13 | 1498.68 | 20 | 14.49 | 2621 | 760 | 3.94 / 905.24 | 5 | 80 |
5 | 13 | 964.64 | 20 | 14.59 | 1835 | 535 | 4.47 / 905.78 | 5 | 91 |
6 | 13 | 207.40 | 20 | 14.85 | 673 | 200 | 4.67 / 905.98 | 5 | 93 |
7 | 8 | 0.08 | 263 | 14.85 | 350 | 1367 | 6.04 / 907.34 | 6 | 130 |
Average= | 17.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 38 | 14.82 | 518 | 292 | 0.29 / 895.51 | 6 | 62 |
2 | 7 | 2009.40 | 40 | 14.52 | 3342 | 1941 | 2.23 / 897.45 | 62 | 67 |
3 | 13 | 1921.36 | 20 | 14.51 | 3215 | 933 | 3.17 / 898.38 | 5 | 72 |
4 | 13 | 1413.96 | 20 | 14.52 | 2502 | 727 | 3.89 / 899.11 | 5 | 84 |
5 | 13 | 912.64 | 20 | 14.61 | 1740 | 508 | 4.40 / 899.62 | 5 | 93 |
6 | 13 | 371.36 | 20 | 14.79 | 913 | 270 | 4.67 / 899.89 | 5 | 98 |
7 | 8 | 0.08 | 263 | 14.84 | 363 | 1417 | 6.09 / 901.30 | 6 | 139 |
Average= | 17.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 38 | 14.83 | 493 | 278 | 0.28 / 889.33 | 6 | 67 |
2 | 7 | 2003.32 | 40 | 14.52 | 3328 | 1933 | 2.21 / 891.27 | 67 | 68 |
3 | 13 | 1919.96 | 20 | 14.50 | 3225 | 935 | 3.15 / 892.20 | 5 | 72 |
4 | 13 | 1510.08 | 20 | 14.50 | 2642 | 766 | 3.91 / 892.97 | 5 | 83 |
5 | 13 | 977.28 | 20 | 14.59 | 1838 | 536 | 4.45 / 893.50 | 5 | 94 |
6 | 13 | 436.56 | 20 | 14.76 | 1011 | 298 | 4.75 / 893.80 | 5 | 98 |
7 | 8 | 0.12 | 276 | 14.85 | 345 | 1414 | 6.16 / 895.22 | 6 | 133 |
Average= | 17.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 38 | 14.83 | 503 | 283 | 0.28 / 883.20 | 6 | 65 |
2 | 7 | 2010.88 | 40 | 14.52 | 3344 | 1942 | 2.23 / 885.14 | 65 | 69 |
3 | 13 | 1930.40 | 20 | 14.50 | 3228 | 936 | 3.16 / 886.07 | 5 | 73 |
4 | 13 | 1520.08 | 20 | 14.50 | 2660 | 771 | 3.93 / 886.85 | 5 | 81 |
5 | 13 | 998.20 | 20 | 14.58 | 1877 | 547 | 4.48 / 887.39 | 5 | 93 |
6 | 13 | 267.24 | 20 | 14.83 | 768 | 228 | 4.71 / 887.62 | 5 | 98 |
7 | 8 | 0.20 | 272 | 14.85 | 355 | 1434 | 6.14 / 889.05 | 6 | 136 |
Average= | 18.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 38 | 14.83 | 506 | 285 | 0.29 / 877.14 | 6 | 65 |
2 | 7 | 2016.88 | 40 | 14.52 | 3355 | 1949 | 2.23 / 879.09 | 65 | 67 |
3 | 13 | 1932.96 | 20 | 14.50 | 3233 | 938 | 3.17 / 880.03 | 5 | 72 |
4 | 13 | 1512.56 | 20 | 14.50 | 2624 | 761 | 3.93 / 880.79 | 5 | 80 |
5 | 13 | 885.80 | 20 | 14.62 | 1712 | 501 | 4.43 / 881.29 | 5 | 96 |
6 | 13 | 352.92 | 20 | 14.80 | 876 | 259 | 4.69 / 881.55 | 5 | 99 |
7 | 8 | -0.08 | 270 | 14.85 | 340 | 1363 | 6.06 / 882.91 | 6 | 138 |
Average= | 18.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 38 | 14.82 | 514 | 289 | 0.29 / 871.00 | 6 | 62 |
2 | 7 | 2005.92 | 40 | 14.52 | 3346 | 1943 | 2.23 / 872.95 | 62 | 66 |
3 | 13 | 1917.72 | 20 | 14.50 | 3222 | 934 | 3.17 / 873.88 | 5 | 74 |
4 | 13 | 1510.36 | 20 | 14.51 | 2632 | 764 | 3.93 / 874.65 | 5 | 80 |
5 | 13 | 974.08 | 20 | 14.60 | 1838 | 537 | 4.47 / 875.18 | 5 | 92 |
6 | 13 | 429.28 | 20 | 14.77 | 1013 | 299 | 4.77 / 875.48 | 5 | 99 |
7 | 8 | 0.44 | 267 | 14.85 | 347 | 1376 | 6.14 / 876.86 | 6 | 133 |
Average= | 18.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 38 | 14.82 | 505 | 284 | 0.28 / 864.80 | 6 | 60 |
2 | 7 | 2008.40 | 40 | 14.52 | 3343 | 1942 | 2.23 / 866.75 | 60 | 65 |
3 | 13 | 1925.08 | 20 | 14.50 | 3228 | 936 | 3.16 / 867.68 | 5 | 70 |
4 | 13 | 1516.28 | 20 | 14.50 | 2641 | 766 | 3.93 / 868.45 | 5 | 80 |
5 | 13 | 1080.36 | 20 | 14.56 | 1991 | 580 | 4.51 / 869.03 | 5 | 90 |
6 | 13 | 413.20 | 20 | 14.78 | 971 | 287 | 4.79 / 869.31 | 5 | 100 |
7 | 8 | 0.00 | 267 | 14.85 | 353 | 1400 | 6.19 / 870.71 | 6 | 134 |
Average= | 18.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 38 | 14.84 | 507 | 286 | 0.29 / 858.56 | 6 | 58 |
2 | 7 | 2005.84 | 40 | 14.52 | 3342 | 1941 | 2.23 / 860.50 | 58 | 69 |
3 | 13 | 1923.60 | 20 | 14.50 | 3237 | 939 | 3.17 / 861.44 | 5 | 72 |
4 | 13 | 1623.64 | 20 | 14.48 | 2816 | 816 | 3.98 / 862.25 | 5 | 78 |
5 | 13 | 1081.68 | 20 | 14.56 | 2009 | 585 | 4.57 / 862.84 | 5 | 91 |
6 | 13 | 427.44 | 20 | 14.77 | 1006 | 297 | 4.86 / 863.14 | 5 | 98 |
7 | 8 | 0.28 | 268 | 14.85 | 348 | 1385 | 6.25 / 864.52 | 6 | 133 |
Average= | 19.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 38 | 14.82 | 523 | 295 | 0.29 / 852.35 | 6 | 66 |
2 | 7 | 2009.60 | 40 | 14.52 | 3355 | 1949 | 2.24 / 854.29 | 66 | 67 |
3 | 13 | 1949.64 | 20 | 14.49 | 3275 | 949 | 3.19 / 855.24 | 5 | 73 |
4 | 13 | 1520.88 | 20 | 14.49 | 2675 | 775 | 3.97 / 856.02 | 5 | 81 |
5 | 13 | 1070.20 | 20 | 14.57 | 1985 | 578 | 4.55 / 856.60 | 5 | 91 |
6 | 13 | 423.72 | 20 | 14.78 | 986 | 291 | 4.84 / 856.89 | 5 | 99 |
7 | 8 | 0.40 | 267 | 14.85 | 349 | 1384 | 6.22 / 858.27 | 6 | 148 |
Average= | 19.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 38 | 14.82 | 514 | 289 | 0.29 / 846.06 | 6 | 67 |
2 | 3 | 1024.72 | 1 | 14.92 | 1959 | 29 | 0.32 / 846.09 | 5 | 29 |
3 | 7 | 2017.04 | 40 | 14.51 | 3360 | 1950 | 2.27 / 848.04 | 29 | 67 |
4 | 13 | 1939.88 | 20 | 14.49 | 3250 | 942 | 3.21 / 848.99 | 5 | 72 |
5 | 13 | 1532.12 | 20 | 14.49 | 2679 | 776 | 3.99 / 849.76 | 5 | 83 |
6 | 13 | 886.40 | 20 | 14.63 | 1715 | 502 | 4.49 / 850.26 | 5 | 96 |
7 | 13 | 522.60 | 20 | 14.73 | 1153 | 340 | 4.83 / 850.60 | 5 | 100 |
8 | 8 | 0.08 | 270 | 14.85 | 361 | 1447 | 6.28 / 852.05 | 6 | 134 |
Average= | 19.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 38 | 14.83 | 507 | 286 | 0.29 / 839.85 | 6 | 69 |
2 | 7 | 2006.40 | 40 | 14.53 | 3333 | 1937 | 2.22 / 841.79 | 69 | 69 |
3 | 13 | 1926.72 | 20 | 14.50 | 3223 | 935 | 3.16 / 842.72 | 5 | 75 |
4 | 13 | 1608.48 | 20 | 14.49 | 2782 | 806 | 3.96 / 843.53 | 5 | 81 |
5 | 13 | 954.60 | 20 | 14.62 | 1813 | 530 | 4.49 / 844.06 | 5 | 93 |
6 | 13 | 318.36 | 20 | 14.82 | 832 | 247 | 4.74 / 844.30 | 6 | 98 |
7 | 8 | 0.28 | 276 | 14.85 | 359 | 1471 | 6.21 / 845.77 | 6 | 133 |
Average= | 20.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 38 | 14.83 | 501 | 282 | 0.28 / 833.62 | 6 | 70 |
2 | 7 | 2013.92 | 40 | 14.53 | 3347 | 1945 | 2.23 / 835.57 | 70 | 70 |
3 | 13 | 1925.32 | 20 | 14.50 | 3233 | 938 | 3.17 / 836.50 | 5 | 74 |
4 | 13 | 1517.80 | 20 | 14.51 | 2642 | 767 | 3.93 / 837.27 | 5 | 82 |
5 | 13 | 972.28 | 20 | 14.61 | 1826 | 534 | 4.47 / 837.80 | 5 | 95 |
6 | 13 | 321.44 | 20 | 14.82 | 840 | 249 | 4.71 / 838.05 | 5 | 100 |
7 | 13 | 51.28 | 20 | 14.90 | 443 | 132 | 4.85 / 838.19 | 6 | 90 |
8 | 13 | 14.12 | 20 | 14.91 | 391 | 117 | 4.96 / 838.30 | 6 | 86 |
9 | 8 | 0.00 | 240 | 14.84 | 354 | 1261 | 6.22 / 839.56 | 6 | 133 |
Average= | 20.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 38 | 14.82 | 514 | 289 | 0.29 / 827.44 | 6 | 69 |
2 | 7 | 2004.60 | 40 | 14.52 | 3342 | 1941 | 2.23 / 829.38 | 13 | 71 |
3 | 13 | 1929.44 | 20 | 14.49 | 3247 | 941 | 3.17 / 830.32 | 5 | 73 |
4 | 13 | 1516.32 | 20 | 14.50 | 2667 | 773 | 3.94 / 831.09 | 5 | 81 |
5 | 13 | 974.36 | 20 | 14.59 | 1861 | 543 | 4.49 / 831.64 | 5 | 92 |
6 | 13 | 315.08 | 20 | 14.81 | 843 | 250 | 4.74 / 831.89 | 5 | 100 |
7 | 8 | 0.36 | 274 | 14.85 | 357 | 1453 | 6.19 / 833.34 | 6 | 129 |
Average= | 20.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 38 | 14.83 | 509 | 287 | 0.29 / 821.13 | 6 | 68 |
2 | 7 | 2017.20 | 40 | 14.53 | 3358 | 1952 | 2.24 / 823.08 | 68 | 66 |
3 | 13 | 1933.08 | 20 | 14.50 | 3237 | 939 | 3.18 / 824.02 | 5 | 71 |
4 | 13 | 1412.08 | 20 | 14.53 | 2512 | 730 | 3.91 / 824.75 | 5 | 85 |
5 | 13 | 1092.28 | 20 | 14.56 | 2023 | 589 | 4.50 / 825.34 | 5 | 89 |
6 | 13 | 624.80 | 20 | 14.70 | 1301 | 382 | 4.88 / 825.72 | 5 | 101 |
7 | 8 | 0.12 | 270 | 14.84 | 357 | 1430 | 6.31 / 827.15 | 6 | 131 |
Average= | 21.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 38 | 14.83 | 535 | 301 | 0.30 / 814.89 | 6 | 67 |
2 | 7 | 2008.60 | 40 | 14.52 | 3337 | 1938 | 2.24 / 816.83 | 67 | 70 |
3 | 13 | 1918.84 | 20 | 14.49 | 3214 | 931 | 3.17 / 817.76 | 5 | 72 |
4 | 13 | 1593.84 | 20 | 14.49 | 2753 | 798 | 3.97 / 818.56 | 5 | 79 |
5 | 13 | 926.60 | 20 | 14.62 | 1759 | 514 | 4.48 / 819.08 | 5 | 93 |
6 | 13 | 487.20 | 20 | 14.75 | 1088 | 321 | 4.80 / 819.40 | 5 | 100 |
7 | 8 | 0.08 | 276 | 14.85 | 352 | 1443 | 6.25 / 820.84 | 6 | 132 |
Average= | 21.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 38 | 14.84 | 502 | 283 | 0.28 / 808.93 | 6 | 66 |
2 | 7 | 2006.36 | 40 | 14.53 | 3344 | 1944 | 2.23 / 810.87 | 8 | 64 |
3 | 13 | 1921.12 | 20 | 14.51 | 3228 | 937 | 3.16 / 811.81 | 5 | 71 |
4 | 13 | 1420.40 | 20 | 14.53 | 2505 | 728 | 3.89 / 812.54 | 5 | 80 |
5 | 13 | 899.12 | 20 | 14.63 | 1718 | 503 | 4.39 / 813.04 | 5 | 93 |
6 | 13 | 156.56 | 20 | 14.88 | 594 | 177 | 4.57 / 813.22 | 6 | 92 |
7 | 8 | -0.20 | 261 | 14.86 | 355 | 1377 | 5.95 / 814.59 | 6 | 137 |
Average= | 22.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 38 | 14.84 | 496 | 280 | 0.28 / 802.82 | 6 | 63 |
2 | 7 | 2006.32 | 40 | 14.54 | 3332 | 1938 | 2.22 / 804.76 | 63 | 67 |
3 | 13 | 1923.00 | 20 | 14.51 | 3233 | 938 | 3.16 / 805.70 | 5 | 71 |
4 | 13 | 1512.76 | 20 | 14.51 | 2642 | 767 | 3.92 / 806.46 | 5 | 79 |
5 | 13 | 970.08 | 20 | 14.61 | 1830 | 535 | 4.46 / 807.00 | 5 | 92 |
6 | 13 | 227.72 | 20 | 14.85 | 712 | 211 | 4.67 / 807.21 | 6 | 100 |
7 | 8 | 0.60 | 270 | 14.86 | 358 | 1436 | 6.11 / 808.65 | 6 | 136 |
Average= | 22.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 38 | 14.84 | 505 | 285 | 0.28 / 796.67 | 6 | 62 |
2 | 7 | 2004.08 | 40 | 14.53 | 3334 | 1938 | 2.22 / 798.61 | 62 | 66 |
3 | 13 | 1917.36 | 20 | 14.51 | 3213 | 932 | 3.15 / 799.54 | 5 | 73 |
4 | 13 | 1491.40 | 20 | 14.52 | 2617 | 760 | 3.91 / 800.30 | 5 | 83 |
5 | 13 | 1062.04 | 20 | 14.58 | 1968 | 574 | 4.49 / 800.88 | 5 | 93 |
6 | 13 | 410.40 | 20 | 14.78 | 977 | 289 | 4.78 / 801.17 | 5 | 103 |
7 | 13 | 39.88 | 20 | 14.91 | 423 | 126 | 4.90 / 801.29 | 5 | 91 |
8 | 8 | -0.12 | 240 | 14.85 | 350 | 1247 | 6.15 / 802.54 | 6 | 129 |
Average= | 22.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 38 | 14.81 | 535 | 301 | 0.30 / 790.53 | 6 | 63 |
2 | 7 | 2004.00 | 40 | 14.53 | 3335 | 1938 | 2.24 / 792.47 | 7 | 65 |
3 | 13 | 1925.08 | 20 | 14.51 | 3243 | 941 | 3.18 / 793.41 | 5 | 71 |
4 | 13 | 1523.88 | 20 | 14.51 | 2669 | 775 | 3.96 / 794.19 | 5 | 80 |
5 | 13 | 1087.80 | 20 | 14.57 | 2014 | 587 | 4.54 / 794.77 | 5 | 90 |
6 | 13 | 314.32 | 20 | 14.82 | 834 | 247 | 4.79 / 795.02 | 5 | 98 |
7 | 8 | -0.12 | 267 | 14.86 | 345 | 1369 | 6.16 / 796.39 | 6 | 136 |
Average= | 23.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 37 | 14.84 | 508 | 279 | 0.28 / 784.26 | 6 | 58 |
2 | 3 | 1027.28 | 1 | 14.90 | 1990 | 30 | 0.31 / 784.29 | 5 | 32 |
3 | 7 | 2014.64 | 40 | 14.52 | 3369 | 1957 | 2.27 / 786.25 | 32 | 65 |
4 | 13 | 1936.72 | 20 | 14.49 | 3255 | 943 | 3.21 / 787.19 | 5 | 70 |
5 | 13 | 1432.08 | 20 | 14.52 | 2541 | 738 | 3.95 / 787.93 | 5 | 82 |
6 | 13 | 1008.80 | 20 | 14.59 | 1907 | 556 | 4.50 / 788.49 | 5 | 93 |
7 | 13 | 450.00 | 20 | 14.76 | 1047 | 309 | 4.81 / 788.80 | 5 | 98 |
8 | 8 | 0.16 | 270 | 14.85 | 358 | 1435 | 6.25 / 790.23 | 6 | 132 |
Average= | 23.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 37 | 14.85 | 512 | 281 | 0.28 / 778.10 | 6 | 57 |
2 | 7 | 2006.68 | 40 | 14.53 | 3340 | 1941 | 2.22 / 780.04 | 57 | 67 |
3 | 13 | 1920.72 | 20 | 14.50 | 3234 | 938 | 3.16 / 780.98 | 5 | 71 |
4 | 13 | 1723.72 | 20 | 14.46 | 2955 | 855 | 4.01 / 781.84 | 5 | 77 |
5 | 13 | 938.08 | 20 | 14.63 | 1790 | 524 | 4.54 / 782.36 | 5 | 95 |
6 | 13 | 308.96 | 20 | 14.83 | 819 | 243 | 4.78 / 782.60 | 5 | 97 |
7 | 8 | 0.28 | 270 | 14.86 | 344 | 1380 | 6.16 / 783.98 | 6 | 149 |
Average= | 24.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 37 | 14.84 | 518 | 284 | 0.28 / 771.88 | 6 | 55 |
2 | 3 | 1019.64 | 1 | 14.92 | 1968 | 29 | 0.31 / 771.91 | 5 | 16 |
3 | 7 | 2014.76 | 40 | 14.52 | 3360 | 1951 | 2.27 / 773.86 | 16 | 68 |
4 | 13 | 1923.84 | 20 | 14.51 | 3236 | 939 | 3.20 / 774.80 | 5 | 73 |
5 | 13 | 1597.12 | 20 | 14.49 | 2768 | 802 | 4.01 / 775.60 | 5 | 79 |
6 | 13 | 1129.00 | 20 | 14.56 | 2075 | 604 | 4.61 / 776.20 | 5 | 90 |
7 | 13 | 357.56 | 20 | 14.81 | 894 | 265 | 4.88 / 776.47 | 5 | 100 |
8 | 8 | 0.32 | 265 | 14.86 | 344 | 1355 | 6.23 / 777.82 | 6 | 131 |
Average= | 25.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 37 | 14.85 | 505 | 277 | 0.28 / 765.71 | 6 | 48 |
2 | 7 | 2015.68 | 40 | 14.51 | 3369 | 1955 | 2.23 / 767.67 | 48 | 66 |
3 | 13 | 1927.48 | 20 | 14.50 | 3256 | 944 | 3.18 / 768.61 | 5 | 68 |
4 | 13 | 1614.76 | 20 | 14.48 | 2803 | 812 | 3.99 / 769.43 | 5 | 77 |
5 | 13 | 865.04 | 20 | 14.65 | 1687 | 494 | 4.48 / 769.92 | 6 | 93 |
6 | 13 | 427.32 | 20 | 14.78 | 1006 | 297 | 4.78 / 770.22 | 6 | 97 |
7 | 8 | 0.04 | 259 | 14.86 | 357 | 1374 | 6.15 / 771.59 | 6 | 130 |
Average= | 25.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 35 | 14.85 | 511 | 266 | 0.27 / 759.48 | 6 | 55 |
2 | 3 | 1055.24 | 1 | 14.87 | 1985 | 30 | 0.30 / 759.50 | 5 | 59 |
3 | 7 | 2014.56 | 40 | 14.53 | 3375 | 1962 | 2.26 / 761.47 | 59 | 65 |
4 | 13 | 1934.00 | 20 | 14.50 | 3253 | 943 | 3.20 / 762.41 | 5 | 68 |
5 | 13 | 1515.12 | 20 | 14.50 | 2676 | 776 | 3.98 / 763.19 | 5 | 82 |
6 | 13 | 1069.48 | 20 | 14.58 | 1992 | 581 | 4.56 / 763.77 | 5 | 89 |
7 | 13 | 411.64 | 20 | 14.79 | 983 | 291 | 4.85 / 764.06 | 6 | 98 |
8 | 8 | 0.20 | 266 | 14.86 | 349 | 1380 | 6.23 / 765.44 | 6 | 131 |
Average= | 26.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 35 | 14.85 | 507 | 264 | 0.26 / 753.27 | 6 | 46 |
2 | 7 | 2013.28 | 40 | 14.53 | 3360 | 1953 | 2.22 / 755.22 | 46 | 65 |
3 | 13 | 1927.92 | 20 | 14.51 | 3228 | 937 | 3.15 / 756.16 | 5 | 70 |
4 | 13 | 1722.40 | 20 | 14.46 | 2966 | 858 | 4.01 / 757.02 | 5 | 75 |
5 | 13 | 944.04 | 20 | 14.62 | 1805 | 528 | 4.54 / 757.55 | 5 | 91 |
6 | 13 | 400.40 | 20 | 14.79 | 977 | 289 | 4.83 / 757.83 | 5 | 96 |
7 | 13 | 33.28 | 20 | 14.91 | 434 | 129 | 4.96 / 757.96 | 6 | 95 |
8 | 8 | 0.00 | 233 | 14.85 | 360 | 1246 | 6.20 / 759.21 | 6 | 130 |
Average= | 27.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 35 | 14.85 | 517 | 269 | 0.27 / 746.95 | 6 | 42 |
2 | 7 | 2010.92 | 41 | 14.52 | 3351 | 1995 | 2.26 / 748.95 | 42 | 64 |
3 | 13 | 1930.56 | 20 | 14.50 | 3258 | 945 | 3.21 / 749.89 | 5 | 71 |
4 | 13 | 1529.08 | 20 | 14.49 | 2677 | 776 | 3.98 / 750.67 | 5 | 79 |
5 | 13 | 1092.16 | 20 | 14.56 | 2019 | 588 | 4.57 / 751.26 | 5 | 91 |
6 | 13 | 441.52 | 20 | 14.77 | 1027 | 303 | 4.88 / 751.56 | 5 | 96 |
7 | 13 | 39.20 | 20 | 14.90 | 440 | 131 | 5.01 / 751.69 | 6 | 94 |
8 | 8 | 0.04 | 249 | 14.85 | 356 | 1316 | 6.32 / 753.01 | 6 | 135 |
Average= | 27.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 35 | 14.85 | 501 | 260 | 0.26 / 740.69 | 6 | 44 |
2 | 7 | 2014.60 | 40 | 14.52 | 3368 | 1956 | 2.22 / 742.65 | 11 | 65 |
3 | 13 | 1932.20 | 20 | 14.50 | 3252 | 943 | 3.16 / 743.59 | 5 | 69 |
4 | 13 | 1525.88 | 20 | 14.50 | 2672 | 775 | 3.93 / 744.36 | 5 | 79 |
5 | 13 | 1077.68 | 20 | 14.57 | 2001 | 583 | 4.52 / 744.95 | 5 | 89 |
6 | 13 | 513.92 | 20 | 14.74 | 1126 | 332 | 4.85 / 745.28 | 5 | 98 |
7 | 13 | 30.04 | 20 | 14.91 | 415 | 124 | 4.97 / 745.40 | 6 | 92 |
8 | 8 | 0.12 | 248 | 14.85 | 348 | 1282 | 6.25 / 746.68 | 6 | 132 |
Average= | 28.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 35 | 14.88 | 491 | 256 | 0.26 / 734.52 | 6 | 42 |
2 | 7 | 2005.44 | 40 | 14.53 | 3343 | 1943 | 2.20 / 736.46 | 42 | 65 |
3 | 13 | 1921.36 | 20 | 14.51 | 3225 | 936 | 3.13 / 737.40 | 5 | 69 |
4 | 13 | 1515.04 | 20 | 14.51 | 2645 | 768 | 3.90 / 738.16 | 5 | 80 |
5 | 13 | 1084.16 | 20 | 14.57 | 2006 | 585 | 4.49 / 738.75 | 5 | 89 |
6 | 13 | 339.12 | 20 | 14.81 | 871 | 258 | 4.74 / 739.01 | 5 | 97 |
7 | 13 | 25.12 | 20 | 14.91 | 411 | 123 | 4.87 / 739.13 | 6 | 95 |
8 | 8 | 0.12 | 246 | 14.85 | 356 | 1301 | 6.17 / 740.43 | 6 | 131 |
Average= | 29.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 35 | 14.86 | 501 | 261 | 0.26 / 728.36 | 6 | 35 |
2 | 7 | 2010.84 | 40 | 14.53 | 3348 | 1946 | 2.21 / 730.30 | 35 | 67 |
3 | 13 | 1924.56 | 20 | 14.52 | 3227 | 937 | 3.14 / 731.24 | 5 | 69 |
4 | 13 | 1719.92 | 20 | 14.47 | 2952 | 854 | 4.00 / 732.09 | 5 | 76 |
5 | 13 | 1057.16 | 20 | 14.58 | 1971 | 575 | 4.57 / 732.67 | 5 | 92 |
6 | 13 | 312.00 | 20 | 14.83 | 827 | 245 | 4.82 / 732.91 | 5 | 97 |
7 | 13 | 40.64 | 20 | 14.91 | 429 | 128 | 4.95 / 733.04 | 6 | 92 |
8 | 8 | 0.04 | 238 | 14.87 | 345 | 1221 | 6.17 / 734.26 | 6 | 141 |
Average= | 30.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 35 | 14.87 | 487 | 253 | 0.25 / 722.25 | 6 | 35 |
2 | 7 | 2006.32 | 40 | 14.53 | 3355 | 1950 | 2.20 / 724.20 | 35 | 65 |
3 | 13 | 1916.80 | 20 | 14.51 | 3218 | 934 | 3.14 / 725.13 | 5 | 70 |
4 | 13 | 1511.12 | 20 | 14.52 | 2639 | 766 | 3.90 / 725.90 | 5 | 79 |
5 | 13 | 1086.00 | 20 | 14.58 | 2001 | 583 | 4.49 / 726.48 | 5 | 87 |
6 | 13 | 416.68 | 20 | 14.78 | 985 | 291 | 4.78 / 726.78 | 5 | 95 |
7 | 13 | 18.32 | 20 | 14.92 | 380 | 113 | 4.89 / 726.89 | 6 | 95 |
8 | 8 | 0.08 | 242 | 14.87 | 335 | 1206 | 6.10 / 728.09 | 6 | 131 |
Average= | 31.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 35 | 14.89 | 498 | 260 | 0.26 / 716.24 | 6 | 37 |
2 | 7 | 2012.84 | 40 | 14.52 | 3345 | 1943 | 2.20 / 718.19 | 37 | 64 |
3 | 13 | 1925.60 | 20 | 14.51 | 3234 | 939 | 3.14 / 719.12 | 5 | 69 |
4 | 13 | 1615.68 | 20 | 14.49 | 2786 | 807 | 3.95 / 719.93 | 5 | 77 |
5 | 13 | 965.16 | 20 | 14.62 | 1813 | 530 | 4.48 / 720.46 | 5 | 91 |
6 | 13 | 314.12 | 20 | 14.82 | 833 | 247 | 4.73 / 720.71 | 6 | 96 |
7 | 13 | 21.48 | 20 | 14.92 | 380 | 113 | 4.84 / 720.82 | 6 | 91 |
8 | 8 | 0.12 | 238 | 14.87 | 332 | 1175 | 6.01 / 722.00 | 6 | 134 |
Average= | 32.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 35 | 14.87 | 502 | 261 | 0.26 / 710.27 | 6 | 39 |
2 | 7 | 2007.60 | 40 | 14.54 | 3338 | 1941 | 2.20 / 712.21 | 39 | 63 |
3 | 13 | 1916.92 | 20 | 14.52 | 3210 | 932 | 3.13 / 713.15 | 5 | 69 |
4 | 13 | 1603.36 | 20 | 14.49 | 2784 | 807 | 3.94 / 713.95 | 5 | 76 |
5 | 13 | 947.84 | 20 | 14.62 | 1799 | 526 | 4.47 / 714.48 | 5 | 91 |
6 | 13 | 307.08 | 20 | 14.83 | 822 | 244 | 4.71 / 714.72 | 6 | 96 |
7 | 8 | 0.16 | 253 | 14.88 | 335 | 1261 | 5.97 / 715.98 | 6 | 129 |
Average= | 34.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 35 | 14.87 | 520 | 271 | 0.27 / 704.29 | 6 | 40 |
2 | 7 | 2010.16 | 40 | 14.53 | 3353 | 1949 | 2.22 / 706.24 | 40 | 64 |
3 | 13 | 1925.76 | 20 | 14.52 | 3229 | 938 | 3.16 / 707.18 | 5 | 70 |
4 | 13 | 1522.44 | 20 | 14.51 | 2664 | 773 | 3.93 / 707.95 | 5 | 79 |
5 | 13 | 984.08 | 20 | 14.61 | 1846 | 539 | 4.47 / 708.49 | 5 | 91 |
6 | 13 | 238.96 | 20 | 14.86 | 710 | 211 | 4.68 / 708.70 | 5 | 92 |
7 | 8 | 0.20 | 263 | 14.88 | 335 | 1311 | 5.99 / 710.01 | 6 | 134 |
Average= | 35.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 35 | 14.86 | 505 | 263 | 0.26 / 698.21 | 6 | 42 |
2 | 7 | 2016.00 | 40 | 14.53 | 3359 | 1952 | 2.21 / 700.17 | 42 | 65 |
3 | 13 | 1932.52 | 20 | 14.51 | 3227 | 936 | 3.15 / 701.10 | 5 | 69 |
4 | 13 | 1526.20 | 20 | 14.51 | 2678 | 777 | 3.93 / 701.88 | 5 | 79 |
5 | 13 | 991.36 | 20 | 14.61 | 1872 | 547 | 4.48 / 702.43 | 5 | 89 |
6 | 13 | 342.76 | 20 | 14.82 | 878 | 260 | 4.74 / 702.69 | 5 | 98 |
7 | 8 | 0.00 | 259 | 14.88 | 346 | 1333 | 6.07 / 704.02 | 6 | 135 |
Average= | 37.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 35 | 14.87 | 509 | 265 | 0.26 / 692.18 | 6 | 44 |
2 | 7 | 2004.72 | 40 | 14.54 | 3339 | 1942 | 2.21 / 694.12 | 44 | 67 |
3 | 13 | 1911.24 | 20 | 14.51 | 3200 | 929 | 3.14 / 695.05 | 5 | 73 |
4 | 13 | 1490.60 | 20 | 14.52 | 2613 | 759 | 3.89 / 695.81 | 5 | 82 |
5 | 13 | 1052.04 | 20 | 14.59 | 1959 | 572 | 4.47 / 696.38 | 5 | 89 |
6 | 13 | 285.44 | 20 | 14.84 | 785 | 233 | 4.70 / 696.61 | 5 | 99 |
7 | 8 | 0.28 | 265 | 14.87 | 339 | 1336 | 6.03 / 697.95 | 6 | 135 |
Average= | 38.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 37 | 14.88 | 492 | 271 | 0.27 / 685.97 | 6 | 43 |
2 | 3 | 950.60 | -1 | 15.30 | 3 | 0 | 0.00 / 685.97 | 6 | 43 |
3 | 7 | 2004.76 | 41 | 14.54 | 3340 | 1991 | 2.26 / 687.96 | 43 | 64 |
4 | 13 | 1911.28 | 20 | 14.51 | 3223 | 935 | 3.20 / 688.90 | 5 | 68 |
5 | 13 | 1497.32 | 20 | 14.52 | 2626 | 763 | 3.96 / 689.66 | 5 | 80 |
6 | 13 | 1059.36 | 20 | 14.59 | 1974 | 576 | 4.54 / 690.24 | 5 | 87 |
7 | 13 | 410.12 | 20 | 14.80 | 985 | 292 | 4.83 / 690.53 | 6 | 96 |
8 | 13 | 30.72 | 20 | 14.92 | 410 | 122 | 4.95 / 690.65 | 6 | 92 |
9 | 8 | -0.12 | 248 | 14.87 | 343 | 1265 | 6.21 / 691.92 | 6 | 135 |
Average= | 40.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 37 | 14.86 | 515 | 283 | 0.28 / 679.95 | 6 | 49 |
2 | 7 | 2010.00 | 41 | 14.54 | 3348 | 1996 | 2.28 / 681.95 | 49 | 64 |
3 | 13 | 1922.64 | 20 | 14.52 | 3229 | 938 | 3.22 / 682.89 | 5 | 71 |
4 | 13 | 1415.88 | 20 | 14.54 | 2506 | 729 | 3.95 / 683.62 | 5 | 79 |
5 | 13 | 986.36 | 20 | 14.62 | 1853 | 542 | 4.49 / 684.16 | 5 | 91 |
6 | 13 | 246.92 | 20 | 14.86 | 722 | 215 | 4.70 / 684.37 | 6 | 94 |
7 | 8 | 0.16 | 261 | 14.88 | 342 | 1328 | 6.03 / 685.70 | 6 | 133 |
Average= | 42.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 37 | 14.86 | 516 | 284 | 0.28 / 673.71 | 6 | 45 |
2 | 7 | 2006.44 | 40 | 14.54 | 3361 | 1955 | 2.24 / 675.66 | 45 | 65 |
3 | 13 | 1927.12 | 20 | 14.52 | 3251 | 944 | 3.18 / 676.61 | 5 | 68 |
4 | 13 | 1508.48 | 20 | 14.52 | 2653 | 770 | 3.95 / 677.38 | 5 | 78 |
5 | 13 | 1053.72 | 20 | 14.59 | 1977 | 577 | 4.53 / 677.96 | 5 | 90 |
6 | 13 | 382.32 | 20 | 14.81 | 947 | 281 | 4.81 / 678.24 | 6 | 95 |
7 | 13 | 13.00 | 20 | 14.93 | 396 | 118 | 4.93 / 678.35 | 6 | 92 |
8 | 8 | 0.12 | 248 | 14.87 | 357 | 1317 | 6.25 / 679.67 | 6 | 133 |
Average= | 45.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 37 | 14.86 | 497 | 273 | 0.27 / 667.58 | 6 | 51 |
2 | 7 | 2012.44 | 40 | 14.54 | 3355 | 1951 | 2.22 / 669.53 | 51 | 64 |
3 | 13 | 1930.84 | 20 | 14.53 | 3219 | 935 | 3.16 / 670.47 | 5 | 68 |
4 | 13 | 1531.76 | 20 | 14.52 | 2678 | 778 | 3.94 / 671.24 | 5 | 80 |
5 | 13 | 896.28 | 20 | 14.66 | 1716 | 503 | 4.44 / 671.75 | 5 | 91 |
6 | 13 | 363.96 | 20 | 14.82 | 917 | 272 | 4.71 / 672.02 | 6 | 98 |
7 | 8 | 0.08 | 267 | 14.88 | 354 | 1406 | 6.12 / 673.43 | 6 | 131 |
Average= | 48.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 37 | 14.86 | 503 | 277 | 0.28 / 661.47 | 6 | 51 |
2 | 7 | 2007.40 | 40 | 14.54 | 3346 | 1946 | 2.22 / 663.41 | 51 | 65 |
3 | 13 | 1917.12 | 20 | 14.53 | 3221 | 936 | 3.16 / 664.35 | 5 | 69 |
4 | 13 | 1506.96 | 20 | 14.52 | 2640 | 767 | 3.93 / 665.11 | 5 | 80 |
5 | 13 | 967.36 | 20 | 14.63 | 1828 | 535 | 4.46 / 665.65 | 5 | 90 |
6 | 13 | 417.04 | 20 | 14.80 | 990 | 293 | 4.75 / 665.94 | 6 | 96 |
7 | 8 | -0.08 | 265 | 14.88 | 346 | 1364 | 6.12 / 667.31 | 6 | 131 |
Average= | 51.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 37 | 14.88 | 476 | 262 | 0.26 / 655.30 | 6 | 49 |
2 | 7 | 2014.80 | 41 | 14.53 | 3367 | 2006 | 2.27 / 657.31 | 49 | 66 |
3 | 13 | 1929.12 | 20 | 14.51 | 3238 | 940 | 3.21 / 658.25 | 5 | 69 |
4 | 13 | 1508.28 | 20 | 14.52 | 2650 | 770 | 3.98 / 659.02 | 5 | 79 |
5 | 13 | 1073.52 | 20 | 14.58 | 1993 | 581 | 4.56 / 659.60 | 5 | 88 |
6 | 13 | 302.44 | 20 | 14.84 | 810 | 240 | 4.80 / 659.84 | 5 | 95 |
7 | 8 | 0.28 | 264 | 14.88 | 343 | 1347 | 6.15 / 661.19 | 6 | 132 |
Average= | 55.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 37 | 14.86 | 518 | 285 | 0.28 / 649.37 | 6 | 52 |
2 | 7 | 2014.20 | 40 | 14.55 | 3349 | 1949 | 2.23 / 651.31 | 52 | 64 |
3 | 13 | 1928.12 | 20 | 14.52 | 3250 | 944 | 3.18 / 652.26 | 5 | 69 |
4 | 13 | 1512.48 | 20 | 14.53 | 2654 | 771 | 3.95 / 653.03 | 5 | 77 |
5 | 13 | 992.92 | 20 | 14.62 | 1869 | 546 | 4.50 / 653.58 | 5 | 90 |
6 | 13 | 351.24 | 20 | 14.82 | 897 | 266 | 4.76 / 653.84 | 5 | 95 |
7 | 8 | -0.04 | 240 | 14.89 | 336 | 1201 | 5.96 / 655.04 | 6 | 132 |
Average= | 59.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 36 | 14.87 | 501 | 268 | 0.27 / 643.16 | 6 | 52 |
2 | 3 | 1018.48 | 1 | 14.95 | 1981 | 30 | 0.30 / 643.19 | 5 | 18 |
3 | 7 | 2016.20 | 40 | 14.55 | 3344 | 1946 | 2.24 / 645.13 | 18 | 64 |
4 | 13 | 1933.00 | 20 | 14.53 | 3237 | 941 | 3.18 / 646.07 | 5 | 68 |
5 | 13 | 1510.72 | 20 | 14.54 | 2645 | 769 | 3.95 / 646.84 | 5 | 77 |
6 | 13 | 1083.12 | 20 | 14.58 | 2006 | 585 | 4.54 / 647.43 | 5 | 88 |
7 | 13 | 420.40 | 20 | 14.80 | 998 | 295 | 4.83 / 647.72 | 5 | 97 |
8 | 8 | 0.16 | 263 | 14.88 | 347 | 1358 | 6.19 / 649.08 | 6 | 132 |
Average= | 64.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 36 | 14.87 | 494 | 264 | 0.26 / 637.17 | 6 | 49 |
2 | 7 | 2007.04 | 40 | 14.54 | 3342 | 1944 | 2.21 / 639.11 | 7 | 65 |
3 | 13 | 1920.56 | 20 | 14.53 | 3232 | 939 | 3.15 / 640.05 | 5 | 69 |
4 | 13 | 1515.16 | 20 | 14.52 | 2642 | 767 | 3.91 / 640.82 | 5 | 78 |
5 | 13 | 984.44 | 20 | 14.62 | 1853 | 542 | 4.46 / 641.36 | 5 | 90 |
6 | 13 | 235.76 | 20 | 14.87 | 716 | 213 | 4.67 / 641.58 | 5 | 91 |
7 | 8 | 0.00 | 261 | 14.89 | 338 | 1314 | 5.98 / 642.89 | 6 | 135 |
Average= | 71.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 37 | 14.91 | 487 | 269 | 0.27 / 631.17 | 6 | 44 |
2 | 7 | 2007.96 | 40 | 14.54 | 3343 | 1944 | 2.21 / 633.11 | 44 | 62 |
3 | 13 | 1915.48 | 20 | 14.51 | 3223 | 935 | 3.15 / 634.05 | 5 | 70 |
4 | 13 | 1501.40 | 20 | 14.52 | 2630 | 764 | 3.91 / 634.81 | 5 | 78 |
5 | 13 | 1061.68 | 20 | 14.59 | 1965 | 573 | 4.49 / 635.39 | 5 | 89 |
6 | 13 | 302.60 | 20 | 14.84 | 801 | 238 | 4.72 / 635.62 | 6 | 94 |
7 | 8 | 0.12 | 257 | 14.88 | 335 | 1281 | 6.00 / 636.91 | 6 | 131 |
Average= | 79.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 36 | 14.88 | 509 | 273 | 0.27 / 625.33 | 6 | 53 |
2 | 7 | 2006.40 | 40 | 14.55 | 3337 | 1942 | 2.21 / 627.27 | 16 | 64 |
3 | 13 | 1926.28 | 20 | 14.54 | 3226 | 938 | 3.15 / 628.21 | 5 | 67 |
4 | 13 | 1502.08 | 20 | 14.53 | 2637 | 766 | 3.92 / 628.98 | 5 | 77 |
5 | 13 | 982.76 | 20 | 14.62 | 1845 | 539 | 4.46 / 629.52 | 5 | 90 |
6 | 13 | 239.36 | 20 | 14.89 | 716 | 213 | 4.67 / 629.73 | 6 | 86 |
7 | 8 | 0.00 | 242 | 14.91 | 325 | 1173 | 5.84 / 630.90 | 6 | 136 |
Average= | 90.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 36 | 14.88 | 503 | 269 | 0.27 / 619.22 | 6 | 49 |
2 | 7 | 2008.96 | 40 | 14.56 | 3342 | 1946 | 2.22 / 621.16 | 49 | 64 |
3 | 13 | 1921.72 | 20 | 14.54 | 3235 | 941 | 3.16 / 622.10 | 5 | 67 |
4 | 13 | 1511.00 | 20 | 14.53 | 2646 | 769 | 3.93 / 622.87 | 5 | 78 |
5 | 13 | 1201.96 | 20 | 14.56 | 2175 | 633 | 4.56 / 623.51 | 5 | 85 |
6 | 13 | 315.80 | 20 | 14.85 | 835 | 248 | 4.81 / 623.75 | 6 | 92 |
7 | 8 | 0.08 | 257 | 14.90 | 340 | 1302 | 6.11 / 625.06 | 6 | 139 |
Average= | 104.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 36 | 14.88 | 520 | 279 | 0.28 / 613.11 | 6 | 50 |
2 | 3 | 1032.64 | 1 | 14.95 | 1969 | 29 | 0.31 / 613.14 | 5 | 37 |
3 | 7 | 2021.96 | 41 | 14.54 | 3353 | 1999 | 2.31 / 615.14 | 37 | 64 |
4 | 13 | 1938.04 | 20 | 14.52 | 3239 | 941 | 3.25 / 616.08 | 5 | 67 |
5 | 13 | 1504.20 | 20 | 14.53 | 2615 | 760 | 4.01 / 616.84 | 5 | 78 |
6 | 13 | 951.84 | 20 | 14.64 | 1804 | 528 | 4.54 / 617.37 | 5 | 89 |
7 | 13 | 323.00 | 20 | 14.84 | 837 | 248 | 4.78 / 617.62 | 6 | 94 |
8 | 8 | 0.36 | 261 | 14.89 | 343 | 1333 | 6.12 / 618.95 | 6 | 136 |
Average= | 123.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 37 | 14.92 | 485 | 268 | 0.27 / 606.99 | 6 | 46 |
2 | 3 | 965.40 | -1 | 15.34 | 3 | 0 | 0.00 / 606.99 | 6 | 46 |
3 | 7 | 2012.68 | 40 | 14.54 | 3352 | 1950 | 2.22 / 608.94 | 46 | 64 |
4 | 13 | 1937.72 | 20 | 14.53 | 3240 | 942 | 3.16 / 609.89 | 5 | 68 |
5 | 13 | 1519.12 | 20 | 14.52 | 2651 | 770 | 3.93 / 610.66 | 5 | 77 |
6 | 13 | 1180.12 | 20 | 14.56 | 2151 | 626 | 4.56 / 611.28 | 5 | 85 |
7 | 13 | 390.96 | 20 | 14.82 | 943 | 280 | 4.83 / 611.56 | 6 | 96 |
8 | 8 | -0.32 | 250 | 14.89 | 341 | 1269 | 6.10 / 612.83 | 6 | 135 |
Average= | 153.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 37 | 14.90 | 509 | 281 | 0.28 / 601.06 | 6 | 50 |
2 | 7 | 2006.08 | 41 | 14.55 | 3341 | 1993 | 2.27 / 603.05 | 50 | 64 |
3 | 13 | 1917.08 | 20 | 14.54 | 3230 | 939 | 3.21 / 603.99 | 5 | 68 |
4 | 13 | 1602.88 | 20 | 14.52 | 2778 | 807 | 4.02 / 604.80 | 5 | 77 |
5 | 13 | 971.36 | 20 | 14.64 | 1828 | 535 | 4.55 / 605.33 | 5 | 89 |
6 | 13 | 225.52 | 20 | 14.90 | 696 | 207 | 4.76 / 605.54 | 6 | 86 |
7 | 8 | 0.24 | 242 | 14.92 | 329 | 1188 | 5.95 / 606.73 | 6 | 132 |
Average= | 202.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 37 | 14.88 | 504 | 277 | 0.28 / 594.92 | 6 | 58 |
2 | 7 | 2013.32 | 40 | 14.55 | 3359 | 1955 | 2.23 / 596.87 | 58 | 66 |
3 | 13 | 1935.08 | 20 | 14.54 | 3250 | 945 | 3.18 / 597.82 | 5 | 68 |
4 | 13 | 1625.00 | 20 | 14.51 | 2823 | 819 | 4.00 / 598.64 | 5 | 77 |
5 | 13 | 1055.40 | 20 | 14.62 | 1955 | 572 | 4.57 / 599.21 | 5 | 88 |
6 | 13 | 390.60 | 20 | 14.83 | 948 | 281 | 4.85 / 599.49 | 5 | 94 |
7 | 8 | 0.12 | 257 | 14.91 | 336 | 1288 | 6.14 / 600.78 | 6 | 133 |
Average= | 300.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 38 | 14.87 | 516 | 292 | 0.29 / 588.73 | 6 | 58 |
2 | 7 | 2010.76 | 40 | 14.56 | 3346 | 1949 | 2.24 / 590.68 | 58 | 65 |
3 | 13 | 1921.60 | 20 | 14.54 | 3214 | 935 | 3.17 / 591.61 | 5 | 70 |
4 | 13 | 1617.24 | 20 | 14.52 | 2812 | 817 | 3.99 / 592.43 | 5 | 76 |
5 | 13 | 964.40 | 20 | 14.65 | 1835 | 538 | 4.53 / 592.96 | 5 | 91 |
6 | 13 | 412.88 | 20 | 14.82 | 979 | 290 | 4.82 / 593.25 | 5 | 98 |
7 | 8 | 0.16 | 265 | 14.89 | 351 | 1385 | 6.20 / 594.64 | 6 | 131 |
Average= | 594.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 37 | 14.87 | 508 | 279 | 0.28 / 582.53 | 6 | 58 |
2 | 7 | 2007.20 | 40 | 14.56 | 3345 | 1948 | 2.23 / 584.47 | 58 | 69 |
3 | 13 | 1913.76 | 20 | 14.55 | 3211 | 934 | 3.16 / 585.41 | 5 | 74 |
4 | 13 | 1601.64 | 20 | 14.53 | 2781 | 808 | 3.97 / 586.22 | 5 | 81 |
5 | 13 | 948.96 | 20 | 14.66 | 1813 | 532 | 4.50 / 586.75 | 5 | 94 |
6 | 13 | 406.04 | 20 | 14.83 | 973 | 289 | 4.79 / 587.04 | 5 | 99 |
7 | 8 | -0.04 | 261 | 14.89 | 360 | 1399 | 6.19 / 588.44 | 6 | 129 |
Average= | 5.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 37 | 14.86 | 526 | 289 | 0.29 / 576.21 | 6 | 56 |
2 | 7 | 2016.00 | 40 | 14.54 | 3385 | 1969 | 2.26 / 578.18 | 56 | 65 |
3 | 13 | 1926.40 | 20 | 14.54 | 3245 | 944 | 3.20 / 579.12 | 5 | 70 |
4 | 13 | 1717.08 | 20 | 14.50 | 2942 | 853 | 4.05 / 579.98 | 5 | 78 |
5 | 13 | 1038.24 | 20 | 14.63 | 1934 | 566 | 4.62 / 580.54 | 5 | 91 |
6 | 13 | 483.08 | 20 | 14.80 | 1079 | 319 | 4.94 / 580.86 | 5 | 101 |
7 | 8 | 0.04 | 267 | 14.90 | 348 | 1384 | 6.32 / 582.25 | 6 | 137 |
Average= | 5.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 37 | 14.88 | 504 | 277 | 0.28 / 569.92 | 6 | 58 |
2 | 7 | 2004.68 | 40 | 14.56 | 3348 | 1950 | 2.23 / 571.87 | 7 | 67 |
3 | 13 | 1923.16 | 20 | 14.55 | 3239 | 943 | 3.17 / 572.81 | 5 | 73 |
4 | 13 | 1610.12 | 20 | 14.52 | 2804 | 814 | 3.98 / 573.63 | 5 | 80 |
5 | 13 | 1066.32 | 20 | 14.62 | 1981 | 579 | 4.56 / 574.21 | 5 | 93 |
6 | 13 | 404.36 | 20 | 14.83 | 969 | 287 | 4.85 / 574.50 | 6 | 99 |
7 | 8 | -0.04 | 266 | 14.89 | 360 | 1426 | 6.28 / 575.92 | 6 | 130 |
Average= | 5.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 37 | 14.88 | 497 | 274 | 0.27 / 563.84 | 6 | 60 |
2 | 7 | 2004.76 | 40 | 14.56 | 3342 | 1946 | 2.22 / 565.79 | 60 | 67 |
3 | 13 | 1919.96 | 20 | 14.54 | 3226 | 938 | 3.16 / 566.73 | 5 | 72 |
4 | 13 | 1492.08 | 20 | 14.55 | 2612 | 760 | 3.92 / 567.49 | 5 | 82 |
5 | 13 | 965.20 | 20 | 14.65 | 1833 | 537 | 4.46 / 568.02 | 5 | 93 |
6 | 13 | 320.00 | 20 | 14.85 | 852 | 253 | 4.71 / 568.28 | 5 | 99 |
7 | 8 | 0.12 | 261 | 14.90 | 352 | 1369 | 6.08 / 569.64 | 6 | 129 |
Average= | 5.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 37 | 14.88 | 512 | 282 | 0.28 / 557.68 | 6 | 58 |
2 | 7 | 2016.44 | 41 | 14.55 | 3368 | 2009 | 2.29 / 559.69 | 58 | 69 |
3 | 13 | 1929.20 | 20 | 14.53 | 3255 | 946 | 3.24 / 560.64 | 5 | 73 |
4 | 13 | 1508.96 | 20 | 14.54 | 2668 | 776 | 4.01 / 561.41 | 5 | 82 |
5 | 13 | 980.76 | 20 | 14.64 | 1863 | 545 | 4.56 / 561.96 | 5 | 93 |
6 | 13 | 323.20 | 20 | 14.85 | 849 | 252 | 4.81 / 562.21 | 5 | 99 |
7 | 8 | 0.24 | 259 | 14.90 | 352 | 1358 | 6.17 / 563.57 | 6 | 135 |
Average= | 5.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 37 | 14.88 | 510 | 281 | 0.28 / 551.64 | 6 | 57 |
2 | 7 | 2012.44 | 40 | 14.56 | 3366 | 1960 | 2.24 / 553.60 | 57 | 66 |
3 | 13 | 1927.84 | 20 | 14.55 | 3250 | 946 | 3.19 / 554.55 | 5 | 71 |
4 | 13 | 1424.04 | 20 | 14.56 | 2517 | 733 | 3.92 / 555.28 | 5 | 82 |
5 | 13 | 914.56 | 20 | 14.66 | 1770 | 519 | 4.44 / 555.80 | 5 | 95 |
6 | 13 | 273.56 | 20 | 14.87 | 782 | 233 | 4.67 / 556.03 | 5 | 99 |
7 | 8 | -0.04 | 261 | 14.90 | 352 | 1369 | 6.04 / 557.40 | 6 | 132 |
Average= | 5.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 37 | 14.87 | 515 | 283 | 0.28 / 545.47 | 6 | 57 |
2 | 7 | 2004.04 | 41 | 14.56 | 3346 | 1997 | 2.28 / 547.47 | 57 | 66 |
3 | 13 | 1918.80 | 20 | 14.54 | 3243 | 943 | 3.22 / 548.42 | 5 | 72 |
4 | 13 | 1498.76 | 20 | 14.55 | 2645 | 770 | 3.99 / 549.18 | 5 | 83 |
5 | 13 | 959.08 | 20 | 14.65 | 1818 | 533 | 4.53 / 549.72 | 5 | 93 |
6 | 13 | 413.96 | 20 | 14.83 | 975 | 289 | 4.82 / 550.01 | 6 | 99 |
7 | 8 | 0.12 | 263 | 14.90 | 345 | 1352 | 6.17 / 551.36 | 6 | 132 |
Average= | 5.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 37 | 14.87 | 501 | 276 | 0.28 / 539.31 | 6 | 59 |
2 | 7 | 2016.72 | 40 | 14.56 | 3376 | 1966 | 2.24 / 541.28 | 59 | 65 |
3 | 13 | 1940.12 | 20 | 14.54 | 3272 | 951 | 3.19 / 542.23 | 5 | 71 |
4 | 13 | 1514.72 | 20 | 14.55 | 2646 | 770 | 3.96 / 543.00 | 5 | 81 |
5 | 13 | 983.72 | 20 | 14.65 | 1857 | 544 | 4.51 / 543.54 | 5 | 93 |
6 | 13 | 334.48 | 20 | 14.85 | 869 | 258 | 4.77 / 543.80 | 5 | 99 |
7 | 8 | 0.16 | 261 | 14.90 | 357 | 1388 | 6.15 / 545.19 | 6 | 133 |
Average= | 5.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 37 | 14.87 | 507 | 279 | 0.28 / 533.16 | 6 | 56 |
2 | 7 | 2006.16 | 40 | 14.57 | 3347 | 1951 | 2.23 / 535.11 | 56 | 67 |
3 | 13 | 1916.44 | 20 | 14.56 | 3231 | 941 | 3.17 / 536.05 | 5 | 70 |
4 | 13 | 1494.84 | 20 | 14.56 | 2624 | 764 | 3.93 / 536.81 | 5 | 80 |
5 | 13 | 944.92 | 20 | 14.66 | 1797 | 527 | 4.46 / 537.34 | 5 | 93 |
6 | 13 | 405.88 | 20 | 14.83 | 974 | 289 | 4.75 / 537.63 | 5 | 100 |
7 | 13 | 36.84 | 20 | 14.95 | 426 | 127 | 4.88 / 537.75 | 6 | 94 |
8 | 8 | 0.04 | 244 | 14.89 | 353 | 1283 | 6.16 / 539.04 | 6 | 130 |
Average= | 5.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 38 | 14.87 | 515 | 291 | 0.29 / 527.10 | 6 | 60 |
2 | 7 | 2016.24 | 40 | 14.57 | 3367 | 1962 | 2.25 / 529.06 | 60 | 66 |
3 | 13 | 1934.56 | 20 | 14.54 | 3249 | 945 | 3.20 / 530.01 | 5 | 72 |
4 | 13 | 1520.84 | 20 | 14.55 | 2658 | 773 | 3.97 / 530.78 | 5 | 82 |
5 | 13 | 972.80 | 20 | 14.65 | 1837 | 538 | 4.51 / 531.32 | 5 | 93 |
6 | 13 | 214.56 | 20 | 14.90 | 683 | 204 | 4.71 / 531.52 | 6 | 97 |
7 | 8 | 0.08 | 261 | 14.90 | 348 | 1353 | 6.07 / 532.88 | 6 | 133 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 37 | 14.88 | 518 | 285 | 0.29 / 520.83 | 6 | 59 |
2 | 3 | 1021.16 | 1 | 14.95 | 1977 | 30 | 0.31 / 520.86 | 5 | 16 |
3 | 7 | 2010.56 | 40 | 14.57 | 3352 | 1954 | 2.27 / 522.82 | 16 | 67 |
4 | 13 | 1916.12 | 20 | 14.55 | 3228 | 939 | 3.21 / 523.76 | 5 | 72 |
5 | 13 | 1605.28 | 20 | 14.53 | 2804 | 815 | 4.02 / 524.57 | 5 | 79 |
6 | 13 | 1047.16 | 20 | 14.63 | 1947 | 570 | 4.59 / 525.14 | 5 | 92 |
7 | 13 | 386.48 | 20 | 14.84 | 934 | 277 | 4.87 / 525.42 | 5 | 100 |
8 | 8 | 0.36 | 267 | 14.90 | 350 | 1392 | 6.26 / 526.81 | 6 | 134 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 37 | 14.87 | 526 | 289 | 0.29 / 514.65 | 6 | 59 |
2 | 7 | 2010.68 | 40 | 14.57 | 3366 | 1962 | 2.25 / 516.61 | 10 | 66 |
3 | 13 | 1927.60 | 20 | 14.55 | 3239 | 943 | 3.19 / 517.56 | 5 | 72 |
4 | 13 | 1517.32 | 20 | 14.55 | 2668 | 776 | 3.97 / 518.33 | 5 | 81 |
5 | 13 | 1077.44 | 20 | 14.62 | 1995 | 583 | 4.55 / 518.92 | 5 | 91 |
6 | 13 | 308.96 | 20 | 14.87 | 815 | 242 | 4.80 / 519.16 | 5 | 99 |
7 | 8 | -0.08 | 263 | 14.90 | 355 | 1391 | 6.19 / 520.55 | 6 | 132 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 37 | 14.87 | 518 | 285 | 0.28 / 508.63 | 6 | 62 |
2 | 7 | 2004.08 | 40 | 14.57 | 3357 | 1956 | 2.24 / 510.59 | 62 | 67 |
3 | 13 | 1922.08 | 20 | 14.54 | 3232 | 940 | 3.18 / 511.53 | 5 | 71 |
4 | 13 | 1411.00 | 20 | 14.57 | 2519 | 734 | 3.92 / 512.26 | 5 | 85 |
5 | 13 | 895.88 | 20 | 14.68 | 1730 | 508 | 4.42 / 512.77 | 5 | 95 |
6 | 13 | 355.88 | 20 | 14.85 | 903 | 268 | 4.69 / 513.04 | 5 | 100 |
7 | 8 | 0.12 | 250 | 14.90 | 356 | 1326 | 6.02 / 514.36 | 6 | 139 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 36 | 14.88 | 515 | 276 | 0.28 / 502.39 | 6 | 55 |
2 | 3 | 1020.20 | 1 | 14.96 | 1989 | 30 | 0.31 / 502.42 | 5 | 20 |
3 | 7 | 2020.04 | 40 | 14.57 | 3387 | 1974 | 2.28 / 504.40 | 20 | 66 |
4 | 13 | 1954.52 | 20 | 14.55 | 3284 | 956 | 3.24 / 505.35 | 5 | 70 |
5 | 13 | 1553.76 | 20 | 14.53 | 2710 | 788 | 4.02 / 506.14 | 5 | 81 |
6 | 13 | 915.12 | 20 | 14.68 | 1754 | 515 | 4.54 / 506.65 | 5 | 93 |
7 | 13 | 571.20 | 20 | 14.77 | 1231 | 364 | 4.90 / 507.02 | 5 | 99 |
8 | 8 | 0.16 | 250 | 14.90 | 356 | 1326 | 6.23 / 508.34 | 6 | 134 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 36 | 14.88 | 520 | 279 | 0.28 / 496.08 | 6 | 55 |
2 | 7 | 2016.00 | 40 | 14.57 | 3371 | 1965 | 2.24 / 498.04 | 55 | 68 |
3 | 13 | 1930.80 | 20 | 14.55 | 3259 | 948 | 3.19 / 498.99 | 5 | 74 |
4 | 13 | 1620.16 | 20 | 14.54 | 2793 | 812 | 4.00 / 499.81 | 5 | 80 |
5 | 13 | 1177.36 | 20 | 14.59 | 2156 | 629 | 4.63 / 500.43 | 5 | 90 |
6 | 13 | 298.92 | 20 | 14.87 | 817 | 243 | 4.88 / 500.68 | 6 | 100 |
7 | 13 | 16.44 | 20 | 14.97 | 396 | 119 | 4.99 / 500.80 | 6 | 93 |
8 | 8 | 0.04 | 249 | 14.90 | 356 | 1321 | 6.32 / 502.12 | 6 | 136 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 36 | 14.89 | 504 | 270 | 0.27 / 489.93 | 6 | 54 |
2 | 7 | 2007.08 | 40 | 14.57 | 3358 | 1957 | 2.23 / 491.89 | 54 | 67 |
3 | 13 | 1927.64 | 20 | 14.55 | 3245 | 944 | 3.17 / 492.83 | 5 | 71 |
4 | 13 | 1627.76 | 20 | 14.53 | 2824 | 821 | 3.99 / 493.65 | 5 | 78 |
5 | 13 | 854.32 | 20 | 14.71 | 1661 | 489 | 4.48 / 494.14 | 5 | 96 |
6 | 13 | 331.92 | 20 | 14.86 | 865 | 257 | 4.74 / 494.40 | 5 | 100 |
7 | 8 | 0.24 | 265 | 14.90 | 355 | 1402 | 6.14 / 495.80 | 6 | 136 |
Average= | 5.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 36 | 14.89 | 503 | 270 | 0.27 / 483.78 | 6 | 55 |
2 | 7 | 2017.36 | 40 | 14.57 | 3371 | 1965 | 2.23 / 485.74 | 55 | 67 |
3 | 13 | 1934.04 | 20 | 14.54 | 3257 | 947 | 3.18 / 486.69 | 5 | 71 |
4 | 13 | 1516.92 | 20 | 14.56 | 2651 | 772 | 3.95 / 487.46 | 5 | 81 |
5 | 13 | 1089.08 | 20 | 14.62 | 2018 | 590 | 4.54 / 488.05 | 5 | 90 |
6 | 13 | 420.52 | 20 | 14.83 | 997 | 296 | 4.84 / 488.35 | 5 | 101 |
7 | 8 | 0.28 | 255 | 14.91 | 346 | 1316 | 6.15 / 489.66 | 6 | 132 |
Average= | 5.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 37 | 14.88 | 503 | 277 | 0.28 / 477.64 | 6 | 57 |
2 | 7 | 2004.48 | 40 | 14.57 | 3344 | 1949 | 2.23 / 479.59 | 57 | 68 |
3 | 13 | 1910.80 | 20 | 14.55 | 3222 | 938 | 3.16 / 480.53 | 5 | 72 |
4 | 13 | 1605.20 | 20 | 14.54 | 2791 | 812 | 3.98 / 481.34 | 5 | 78 |
5 | 13 | 1050.96 | 20 | 14.64 | 1976 | 579 | 4.55 / 481.92 | 5 | 92 |
6 | 13 | 287.52 | 20 | 14.88 | 789 | 235 | 4.79 / 482.15 | 5 | 100 |
7 | 8 | 0.00 | 263 | 14.91 | 346 | 1357 | 6.15 / 483.51 | 6 | 129 |
Average= | 5.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 37 | 14.89 | 503 | 277 | 0.28 / 471.43 | 6 | 56 |
2 | 7 | 2008.00 | 40 | 14.58 | 3349 | 1953 | 2.23 / 473.39 | 56 | 66 |
3 | 13 | 1920.92 | 20 | 14.56 | 3232 | 941 | 3.17 / 474.33 | 5 | 72 |
4 | 13 | 1506.96 | 20 | 14.56 | 2656 | 773 | 3.94 / 475.10 | 5 | 81 |
5 | 13 | 970.84 | 20 | 14.66 | 1847 | 542 | 4.49 / 475.64 | 5 | 93 |
6 | 13 | 524.04 | 20 | 14.79 | 1156 | 342 | 4.83 / 475.99 | 5 | 102 |
7 | 8 | 0.08 | 263 | 14.91 | 351 | 1376 | 6.20 / 477.36 | 6 | 131 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 37 | 14.88 | 503 | 277 | 0.28 / 465.28 | 6 | 57 |
2 | 7 | 2007.64 | 40 | 14.58 | 3345 | 1951 | 2.23 / 467.23 | 57 | 67 |
3 | 13 | 1916.92 | 20 | 14.55 | 3234 | 941 | 3.17 / 468.17 | 5 | 72 |
4 | 13 | 1601.84 | 20 | 14.55 | 2770 | 806 | 3.97 / 468.98 | 5 | 79 |
5 | 13 | 1050.48 | 20 | 14.64 | 1969 | 577 | 4.55 / 469.56 | 5 | 91 |
6 | 13 | 273.08 | 20 | 14.89 | 771 | 230 | 4.78 / 469.79 | 5 | 100 |
7 | 8 | 0.08 | 266 | 14.91 | 346 | 1372 | 6.15 / 471.16 | 6 | 130 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 37 | 14.88 | 517 | 285 | 0.28 / 459.05 | 6 | 59 |
2 | 7 | 2005.92 | 40 | 14.58 | 3351 | 1954 | 2.24 / 461.00 | 59 | 66 |
3 | 13 | 1921.88 | 20 | 14.56 | 3240 | 943 | 3.18 / 461.95 | 5 | 72 |
4 | 13 | 1513.28 | 20 | 14.55 | 2667 | 776 | 3.96 / 462.72 | 5 | 81 |
5 | 13 | 1076.52 | 20 | 14.63 | 2006 | 587 | 4.55 / 463.31 | 5 | 91 |
6 | 13 | 402.56 | 20 | 14.83 | 980 | 291 | 4.84 / 463.60 | 5 | 100 |
7 | 8 | 0.28 | 268 | 14.91 | 351 | 1403 | 6.24 / 465.00 | 6 | 132 |
Average= | 5.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 37 | 14.89 | 504 | 278 | 0.28 / 452.90 | 6 | 57 |
2 | 7 | 2012.76 | 40 | 14.57 | 3358 | 1957 | 2.23 / 454.85 | 57 | 67 |
3 | 13 | 1921.00 | 20 | 14.55 | 3261 | 949 | 3.18 / 455.80 | 5 | 72 |
4 | 13 | 1721.44 | 20 | 14.51 | 2976 | 864 | 4.05 / 456.67 | 5 | 77 |
5 | 13 | 941.76 | 20 | 14.68 | 1797 | 528 | 4.57 / 457.19 | 5 | 95 |
6 | 13 | 290.28 | 20 | 14.88 | 804 | 239 | 4.81 / 457.43 | 6 | 101 |
7 | 8 | -0.16 | 253 | 14.91 | 353 | 1332 | 6.15 / 458.77 | 6 | 134 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 37 | 14.89 | 503 | 277 | 0.28 / 446.79 | 6 | 59 |
2 | 7 | 2012.20 | 40 | 14.58 | 3346 | 1951 | 2.23 / 448.75 | 59 | 67 |
3 | 13 | 1926.08 | 20 | 14.57 | 3250 | 947 | 3.18 / 449.69 | 5 | 71 |
4 | 13 | 1512.08 | 20 | 14.57 | 2667 | 777 | 3.95 / 450.47 | 5 | 81 |
5 | 13 | 969.08 | 20 | 14.67 | 1848 | 542 | 4.49 / 451.01 | 5 | 93 |
6 | 13 | 214.32 | 20 | 14.91 | 683 | 204 | 4.70 / 451.22 | 5 | 99 |
7 | 8 | 0.24 | 266 | 14.91 | 354 | 1404 | 6.10 / 452.62 | 6 | 134 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 37 | 14.89 | 498 | 274 | 0.27 / 440.78 | 6 | 59 |
2 | 7 | 2009.76 | 40 | 14.58 | 3359 | 1959 | 2.23 / 442.74 | 59 | 68 |
3 | 13 | 1923.00 | 20 | 14.56 | 3254 | 948 | 3.18 / 443.69 | 5 | 73 |
4 | 13 | 1403.80 | 20 | 14.59 | 2491 | 727 | 3.91 / 444.42 | 5 | 84 |
5 | 13 | 885.04 | 20 | 14.69 | 1713 | 503 | 4.41 / 444.92 | 5 | 95 |
6 | 13 | 258.48 | 20 | 14.89 | 755 | 225 | 4.64 / 445.14 | 6 | 99 |
7 | 8 | 0.24 | 264 | 14.91 | 349 | 1374 | 6.01 / 446.52 | 6 | 136 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 37 | 14.89 | 501 | 276 | 0.28 / 434.60 | 6 | 59 |
2 | 7 | 2012.20 | 40 | 14.59 | 3364 | 1963 | 2.24 / 436.57 | 59 | 66 |
3 | 13 | 1920.08 | 20 | 14.57 | 3245 | 946 | 3.18 / 437.51 | 5 | 71 |
4 | 13 | 1603.60 | 20 | 14.55 | 2789 | 812 | 4.00 / 438.32 | 5 | 79 |
5 | 13 | 955.08 | 20 | 14.68 | 1815 | 533 | 4.53 / 438.86 | 5 | 94 |
6 | 13 | 313.64 | 20 | 14.88 | 829 | 247 | 4.78 / 439.10 | 5 | 100 |
7 | 8 | -0.24 | 272 | 14.92 | 346 | 1404 | 6.18 / 440.51 | 6 | 138 |
Average= | 5.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 37 | 14.88 | 509 | 280 | 0.28 / 428.54 | 6 | 64 |
2 | 7 | 2005.44 | 40 | 14.60 | 3331 | 1945 | 2.23 / 430.49 | 64 | 67 |
3 | 13 | 1916.68 | 20 | 14.59 | 3214 | 938 | 3.16 / 431.43 | 5 | 72 |
4 | 13 | 1511.88 | 20 | 14.58 | 2634 | 768 | 3.93 / 432.19 | 5 | 83 |
5 | 13 | 880.60 | 20 | 14.71 | 1696 | 499 | 4.43 / 432.69 | 5 | 95 |
6 | 13 | 340.16 | 20 | 14.87 | 878 | 261 | 4.69 / 432.95 | 5 | 100 |
7 | 8 | 0.08 | 263 | 14.91 | 350 | 1372 | 6.06 / 434.33 | 6 | 129 |
Average= | 5.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 37 | 14.89 | 504 | 278 | 0.28 / 422.40 | 6 | 61 |
2 | 7 | 2012.12 | 40 | 14.59 | 3352 | 1956 | 2.23 / 424.36 | 61 | 67 |
3 | 13 | 1926.92 | 20 | 14.57 | 3241 | 944 | 3.18 / 425.30 | 5 | 72 |
4 | 13 | 1497.36 | 20 | 14.58 | 2618 | 763 | 3.94 / 426.06 | 5 | 81 |
5 | 13 | 957.48 | 20 | 14.68 | 1808 | 531 | 4.47 / 426.59 | 5 | 94 |
6 | 13 | 406.68 | 20 | 14.85 | 965 | 287 | 4.76 / 426.88 | 5 | 101 |
7 | 8 | 0.00 | 267 | 14.92 | 347 | 1382 | 6.14 / 428.26 | 6 | 135 |
Average= | 5.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 38 | 14.89 | 507 | 287 | 0.29 / 416.33 | 6 | 64 |
2 | 7 | 2009.92 | 41 | 14.58 | 3360 | 2009 | 2.30 / 418.34 | 64 | 69 |
3 | 13 | 1919.44 | 20 | 14.57 | 3236 | 943 | 3.24 / 419.28 | 5 | 73 |
4 | 13 | 1406.32 | 20 | 14.60 | 2490 | 727 | 3.97 / 420.01 | 5 | 86 |
5 | 13 | 880.72 | 20 | 14.71 | 1695 | 499 | 4.46 / 420.51 | 5 | 97 |
6 | 13 | 239.24 | 20 | 14.91 | 733 | 219 | 4.68 / 420.73 | 5 | 101 |
7 | 8 | 0.28 | 265 | 14.92 | 353 | 1396 | 6.08 / 422.12 | 6 | 136 |
Average= | 5.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 37 | 14.89 | 497 | 274 | 0.27 / 410.21 | 6 | 63 |
2 | 7 | 2003.28 | 40 | 14.59 | 3332 | 1945 | 2.22 / 412.15 | 63 | 68 |
3 | 13 | 1914.16 | 20 | 14.57 | 3227 | 940 | 3.16 / 413.09 | 5 | 74 |
4 | 13 | 1597.20 | 20 | 14.56 | 2771 | 807 | 3.97 / 413.90 | 5 | 80 |
5 | 13 | 926.00 | 20 | 14.70 | 1762 | 518 | 4.48 / 414.42 | 5 | 96 |
6 | 13 | 291.80 | 20 | 14.90 | 799 | 238 | 4.72 / 414.66 | 5 | 100 |
7 | 8 | 0.08 | 267 | 14.92 | 348 | 1386 | 6.11 / 416.04 | 6 | 131 |
Average= | 5.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 37 | 14.89 | 511 | 282 | 0.28 / 404.14 | 6 | 64 |
2 | 7 | 2014.32 | 41 | 14.58 | 3379 | 2020 | 2.30 / 406.16 | 64 | 71 |
3 | 13 | 1924.40 | 20 | 14.56 | 3251 | 947 | 3.25 / 407.10 | 5 | 76 |
4 | 13 | 1477.48 | 20 | 14.58 | 2596 | 757 | 4.01 / 407.86 | 5 | 86 |
5 | 13 | 839.60 | 20 | 14.72 | 1648 | 485 | 4.49 / 408.34 | 5 | 98 |
6 | 13 | 201.04 | 20 | 14.93 | 659 | 197 | 4.69 / 408.54 | 6 | 96 |
7 | 8 | 0.16 | 267 | 14.92 | 350 | 1394 | 6.08 / 409.94 | 6 | 134 |
Average= | 5.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 37 | 14.89 | 502 | 277 | 0.28 / 398.13 | 6 | 65 |
2 | 7 | 2007.12 | 40 | 14.59 | 3349 | 1954 | 2.23 / 400.08 | 65 | 69 |
3 | 13 | 1921.08 | 20 | 14.57 | 3244 | 945 | 3.18 / 401.03 | 5 | 73 |
4 | 13 | 1401.24 | 20 | 14.60 | 2495 | 729 | 3.90 / 401.75 | 5 | 84 |
5 | 13 | 966.92 | 20 | 14.68 | 1842 | 541 | 4.45 / 402.30 | 5 | 95 |
6 | 13 | 199.04 | 20 | 14.93 | 665 | 199 | 4.64 / 402.49 | 6 | 95 |
7 | 8 | 0.12 | 259 | 14.92 | 352 | 1360 | 6.00 / 403.85 | 6 | 133 |
Average= | 5.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 37 | 14.89 | 508 | 280 | 0.28 / 392.04 | 6 | 64 |
2 | 7 | 2007.88 | 40 | 14.59 | 3354 | 1957 | 2.24 / 393.99 | 64 | 68 |
3 | 13 | 1921.28 | 20 | 14.56 | 3241 | 944 | 3.18 / 394.94 | 5 | 74 |
4 | 13 | 1505.04 | 20 | 14.58 | 2647 | 772 | 3.95 / 395.71 | 5 | 84 |
5 | 13 | 863.84 | 20 | 14.72 | 1678 | 494 | 4.45 / 396.20 | 5 | 96 |
6 | 13 | 320.76 | 20 | 14.89 | 849 | 253 | 4.70 / 396.46 | 5 | 101 |
7 | 8 | -0.12 | 266 | 14.93 | 351 | 1394 | 6.09 / 397.85 | 6 | 131 |
Average= | 5.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 37 | 14.91 | 506 | 279 | 0.28 / 386.00 | 6 | 61 |
2 | 7 | 2006.36 | 40 | 14.61 | 3344 | 1954 | 2.23 / 387.95 | 61 | 69 |
3 | 13 | 1921.44 | 20 | 14.59 | 3243 | 946 | 3.18 / 388.90 | 5 | 73 |
4 | 13 | 1502.36 | 20 | 14.59 | 2623 | 765 | 3.95 / 389.66 | 5 | 83 |
5 | 13 | 882.56 | 20 | 14.71 | 1713 | 504 | 4.45 / 390.17 | 5 | 95 |
6 | 13 | 233.60 | 20 | 14.93 | 715 | 213 | 4.66 / 390.38 | 6 | 100 |
7 | 8 | 0.28 | 263 | 14.93 | 350 | 1374 | 6.04 / 391.76 | 6 | 133 |
Average= | 5.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 37 | 14.90 | 503 | 277 | 0.28 / 379.92 | 6 | 61 |
2 | 7 | 2006.52 | 40 | 14.61 | 3347 | 1956 | 2.23 / 381.88 | 61 | 67 |
3 | 13 | 1923.04 | 20 | 14.58 | 3231 | 942 | 3.18 / 382.82 | 5 | 72 |
4 | 13 | 1415.20 | 20 | 14.61 | 2500 | 730 | 3.91 / 383.55 | 5 | 84 |
5 | 13 | 895.40 | 20 | 14.71 | 1724 | 507 | 4.41 / 384.06 | 5 | 96 |
6 | 13 | 363.80 | 20 | 14.88 | 906 | 270 | 4.68 / 384.33 | 5 | 100 |
7 | 8 | 0.16 | 264 | 14.93 | 353 | 1391 | 6.07 / 385.72 | 6 | 134 |
Average= | 5.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 37 | 14.91 | 509 | 281 | 0.28 / 373.83 | 6 | 60 |
2 | 7 | 2009.08 | 40 | 14.60 | 3350 | 1956 | 2.24 / 375.78 | 6 | 68 |
3 | 13 | 1922.44 | 20 | 14.58 | 3233 | 943 | 3.18 / 376.73 | 5 | 73 |
4 | 13 | 1509.72 | 20 | 14.59 | 2645 | 772 | 3.95 / 377.50 | 5 | 82 |
5 | 13 | 959.32 | 20 | 14.69 | 1808 | 531 | 4.48 / 378.03 | 5 | 95 |
6 | 13 | 303.36 | 20 | 14.90 | 811 | 242 | 4.72 / 378.27 | 5 | 102 |
7 | 8 | -0.04 | 265 | 14.94 | 347 | 1374 | 6.10 / 379.64 | 6 | 133 |
Average= | 5.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 37 | 14.91 | 506 | 279 | 0.28 / 367.73 | 6 | 60 |
2 | 7 | 2010.68 | 40 | 14.60 | 3364 | 1965 | 2.24 / 369.70 | 60 | 68 |
3 | 13 | 1916.00 | 20 | 14.58 | 3233 | 943 | 3.19 / 370.64 | 5 | 73 |
4 | 13 | 1597.16 | 20 | 14.58 | 2762 | 805 | 3.99 / 371.45 | 5 | 82 |
5 | 13 | 920.92 | 20 | 14.71 | 1754 | 516 | 4.51 / 371.96 | 5 | 96 |
6 | 13 | 264.92 | 20 | 14.92 | 761 | 227 | 4.73 / 372.19 | 6 | 101 |
7 | 8 | 0.24 | 265 | 14.94 | 343 | 1358 | 6.09 / 373.55 | 6 | 130 |
Average= | 5.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 37 | 14.93 | 515 | 284 | 0.28 / 361.59 | 6 | 60 |
2 | 7 | 2009.36 | 40 | 14.60 | 3348 | 1955 | 2.24 / 363.55 | 6 | 68 |
3 | 13 | 1929.20 | 20 | 14.59 | 3244 | 947 | 3.19 / 364.49 | 5 | 72 |
4 | 13 | 1499.52 | 20 | 14.60 | 2626 | 767 | 3.95 / 365.26 | 5 | 83 |
5 | 13 | 945.24 | 20 | 14.71 | 1800 | 530 | 4.48 / 365.79 | 5 | 95 |
6 | 13 | 381.68 | 20 | 14.88 | 938 | 279 | 4.76 / 366.07 | 5 | 100 |
7 | 8 | 0.16 | 263 | 14.94 | 352 | 1383 | 6.14 / 367.45 | 6 | 134 |
Average= | 5.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 37 | 14.93 | 487 | 269 | 0.27 / 355.60 | 6 | 58 |
2 | 7 | 2010.16 | 40 | 14.60 | 3350 | 1956 | 2.23 / 357.55 | 58 | 68 |
3 | 13 | 1920.44 | 20 | 14.59 | 3230 | 943 | 3.17 / 358.50 | 5 | 73 |
4 | 13 | 1483.72 | 20 | 14.60 | 2599 | 759 | 3.93 / 359.26 | 5 | 83 |
5 | 13 | 957.08 | 20 | 14.72 | 1818 | 535 | 4.46 / 359.79 | 5 | 95 |
6 | 13 | 212.00 | 20 | 14.96 | 666 | 199 | 4.66 / 359.99 | 6 | 94 |
7 | 8 | 0.28 | 259 | 14.97 | 340 | 1318 | 5.98 / 361.31 | 6 | 136 |
Average= | 5.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 37 | 14.93 | 511 | 282 | 0.28 / 349.54 | 6 | 59 |
2 | 7 | 2007.76 | 40 | 14.62 | 3340 | 1953 | 2.24 / 351.49 | 59 | 67 |
3 | 13 | 1924.48 | 20 | 14.59 | 3249 | 948 | 3.18 / 352.44 | 5 | 73 |
4 | 13 | 1506.76 | 20 | 14.60 | 2642 | 771 | 3.96 / 353.21 | 5 | 83 |
5 | 13 | 969.12 | 20 | 14.70 | 1828 | 537 | 4.49 / 353.75 | 5 | 95 |
6 | 13 | 310.64 | 20 | 14.91 | 829 | 247 | 4.74 / 354.00 | 5 | 100 |
7 | 13 | 17.48 | 20 | 15.01 | 380 | 114 | 4.85 / 354.11 | 6 | 92 |
8 | 8 | 0.24 | 240 | 14.95 | 339 | 1216 | 6.07 / 355.33 | 6 | 133 |
Average= | 5.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 37 | 14.92 | 508 | 280 | 0.28 / 343.59 | 6 | 58 |
2 | 7 | 2005.08 | 41 | 14.61 | 3344 | 2003 | 2.28 / 345.59 | 58 | 68 |
3 | 13 | 1917.08 | 20 | 14.60 | 3241 | 946 | 3.23 / 346.54 | 5 | 73 |
4 | 13 | 1398.96 | 20 | 14.63 | 2468 | 722 | 3.95 / 347.26 | 5 | 85 |
5 | 13 | 869.96 | 20 | 14.74 | 1673 | 493 | 4.45 / 347.76 | 5 | 96 |
6 | 13 | 131.56 | 20 | 14.98 | 560 | 168 | 4.61 / 347.92 | 6 | 96 |
7 | 8 | -0.16 | 261 | 14.96 | 342 | 1335 | 5.95 / 349.26 | 6 | 138 |
Average= | 5.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 36 | 14.94 | 493 | 265 | 0.27 / 337.40 | 6 | 56 |
2 | 7 | 2004.56 | 40 | 14.62 | 3345 | 1956 | 2.22 / 339.36 | 56 | 68 |
3 | 13 | 1923.32 | 20 | 14.59 | 3251 | 949 | 3.17 / 340.31 | 5 | 72 |
4 | 13 | 1502.48 | 20 | 14.61 | 2652 | 775 | 3.94 / 341.08 | 5 | 82 |
5 | 13 | 1072.36 | 20 | 14.67 | 1996 | 586 | 4.53 / 341.67 | 5 | 93 |
6 | 13 | 401.12 | 20 | 14.89 | 955 | 284 | 4.81 / 341.95 | 5 | 100 |
7 | 8 | -0.04 | 265 | 14.96 | 342 | 1356 | 6.17 / 343.31 | 6 | 132 |
Average= | 5.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 36 | 14.95 | 501 | 270 | 0.27 / 331.43 | 6 | 55 |
2 | 7 | 2004.52 | 40 | 14.62 | 3346 | 1957 | 2.23 / 333.38 | 6 | 68 |
3 | 13 | 1922.52 | 20 | 14.60 | 3229 | 943 | 3.17 / 334.33 | 5 | 73 |
4 | 13 | 1502.20 | 20 | 14.61 | 2640 | 771 | 3.94 / 335.10 | 5 | 83 |
5 | 13 | 958.60 | 20 | 14.71 | 1823 | 536 | 4.48 / 335.64 | 5 | 94 |
6 | 13 | 211.76 | 20 | 14.96 | 679 | 203 | 4.68 / 335.84 | 6 | 97 |
7 | 8 | 0.28 | 261 | 14.97 | 333 | 1301 | 5.98 / 337.14 | 6 | 132 |
Average= | 5.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 36 | 14.94 | 511 | 275 | 0.27 / 325.24 | 6 | 56 |
2 | 7 | 2015.76 | 40 | 14.62 | 3362 | 1966 | 2.24 / 327.20 | 12 | 67 |
3 | 13 | 1928.32 | 20 | 14.61 | 3242 | 947 | 3.19 / 328.15 | 5 | 73 |
4 | 13 | 1719.60 | 20 | 14.57 | 2963 | 863 | 4.05 / 329.01 | 5 | 78 |
5 | 13 | 1043.92 | 20 | 14.71 | 1949 | 573 | 4.63 / 329.59 | 5 | 93 |
6 | 13 | 298.72 | 20 | 14.94 | 808 | 241 | 4.87 / 329.83 | 5 | 98 |
7 | 13 | 18.12 | 20 | 15.03 | 382 | 115 | 4.98 / 329.94 | 6 | 93 |
8 | 8 | -0.08 | 240 | 14.98 | 338 | 1215 | 6.20 / 331.16 | 6 | 133 |
Average= | 5.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 36 | 14.95 | 505 | 272 | 0.27 / 319.07 | 6 | 53 |
2 | 7 | 2010.68 | 40 | 14.62 | 3350 | 1959 | 2.23 / 321.03 | 53 | 69 |
3 | 13 | 1919.52 | 20 | 14.60 | 3226 | 942 | 3.17 / 321.97 | 5 | 73 |
4 | 13 | 1716.16 | 20 | 14.57 | 2952 | 860 | 4.03 / 322.83 | 5 | 78 |
5 | 13 | 933.00 | 20 | 14.74 | 1780 | 525 | 4.56 / 323.36 | 5 | 95 |
6 | 13 | 284.80 | 20 | 14.94 | 790 | 236 | 4.79 / 323.59 | 6 | 101 |
7 | 8 | 0.16 | 265 | 14.97 | 345 | 1369 | 6.16 / 324.96 | 6 | 134 |
Average= | 5.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 35 | 14.96 | 504 | 264 | 0.26 / 312.98 | 6 | 50 |
2 | 7 | 2006.96 | 40 | 14.62 | 3335 | 1950 | 2.21 / 314.93 | 6 | 68 |
3 | 13 | 1912.04 | 20 | 14.60 | 3210 | 937 | 3.15 / 315.87 | 5 | 72 |
4 | 13 | 1703.64 | 20 | 14.58 | 2919 | 851 | 4.00 / 316.72 | 5 | 78 |
5 | 13 | 920.32 | 20 | 14.75 | 1758 | 519 | 4.52 / 317.24 | 5 | 95 |
6 | 13 | 281.44 | 20 | 14.95 | 787 | 235 | 4.76 / 317.47 | 5 | 100 |
7 | 8 | 0.08 | 259 | 14.98 | 342 | 1327 | 6.08 / 318.80 | 6 | 135 |
Average= | 5.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 35 | 14.98 | 498 | 261 | 0.26 / 306.97 | 6 | 51 |
2 | 7 | 2010.20 | 41 | 14.62 | 3338 | 2001 | 2.26 / 308.97 | 51 | 70 |
3 | 13 | 1919.96 | 20 | 14.60 | 3223 | 941 | 3.20 / 309.92 | 5 | 73 |
4 | 13 | 1502.76 | 20 | 14.62 | 2622 | 767 | 3.97 / 310.68 | 5 | 82 |
5 | 13 | 962.40 | 20 | 14.74 | 1802 | 531 | 4.50 / 311.21 | 5 | 95 |
6 | 13 | 306.76 | 20 | 14.94 | 814 | 243 | 4.74 / 311.46 | 5 | 97 |
7 | 8 | 0.20 | 257 | 14.99 | 327 | 1260 | 6.00 / 312.72 | 6 | 136 |
Average= | 5.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 36 | 14.99 | 497 | 268 | 0.27 / 300.96 | 6 | 50 |
2 | 7 | 2008.56 | 40 | 14.64 | 3344 | 1958 | 2.23 / 302.92 | 50 | 68 |
3 | 13 | 1922.80 | 20 | 14.62 | 3221 | 942 | 3.17 / 303.86 | 5 | 73 |
4 | 13 | 1524.00 | 20 | 14.63 | 2642 | 773 | 3.94 / 304.64 | 5 | 82 |
5 | 13 | 988.64 | 20 | 14.73 | 1855 | 546 | 4.49 / 305.18 | 5 | 93 |
6 | 13 | 328.00 | 20 | 14.95 | 841 | 251 | 4.74 / 305.43 | 6 | 96 |
7 | 8 | -0.08 | 257 | 14.99 | 332 | 1279 | 6.02 / 306.71 | 6 | 135 |
Average= | 5.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 35 | 14.97 | 518 | 271 | 0.27 / 295.11 | 6 | 50 |
2 | 3 | 1025.04 | 1 | 15.01 | 1980 | 30 | 0.30 / 295.14 | 5 | 22 |
3 | 7 | 2006.96 | 40 | 14.63 | 3337 | 1953 | 2.25 / 297.09 | 22 | 69 |
4 | 13 | 1912.84 | 20 | 14.62 | 3207 | 938 | 3.19 / 298.03 | 5 | 73 |
5 | 13 | 1596.52 | 20 | 14.61 | 2773 | 810 | 4.00 / 298.84 | 5 | 81 |
6 | 13 | 842.20 | 20 | 14.79 | 1640 | 485 | 4.49 / 299.32 | 5 | 96 |
7 | 13 | 200.68 | 20 | 15.00 | 651 | 195 | 4.68 / 299.52 | 6 | 94 |
8 | 8 | 0.04 | 235 | 15.01 | 333 | 1175 | 5.86 / 300.69 | 6 | 131 |
Average= | 5.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 35 | 14.99 | 499 | 262 | 0.26 / 288.98 | 6 | 45 |
2 | 7 | 2006.44 | 41 | 14.64 | 3339 | 2004 | 2.27 / 290.98 | 6 | 68 |
3 | 13 | 1912.72 | 20 | 14.61 | 3226 | 943 | 3.21 / 291.93 | 5 | 73 |
4 | 13 | 1484.20 | 20 | 14.63 | 2620 | 767 | 3.98 / 292.69 | 5 | 83 |
5 | 13 | 950.04 | 20 | 14.75 | 1800 | 531 | 4.51 / 293.22 | 5 | 94 |
6 | 13 | 394.60 | 20 | 14.92 | 951 | 284 | 4.79 / 293.51 | 6 | 100 |
7 | 8 | 0.24 | 261 | 14.99 | 340 | 1330 | 6.12 / 294.84 | 6 | 130 |
Average= | 5.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 35 | 14.99 | 488 | 256 | 0.26 / 283.00 | 6 | 46 |
2 | 7 | 2014.00 | 40 | 14.64 | 3345 | 1959 | 2.21 / 284.96 | 6 | 68 |
3 | 13 | 1937.44 | 20 | 14.63 | 3247 | 950 | 3.16 / 285.91 | 5 | 72 |
4 | 13 | 1514.44 | 20 | 14.64 | 2651 | 776 | 3.94 / 286.69 | 5 | 82 |
5 | 13 | 972.76 | 20 | 14.75 | 1842 | 543 | 4.48 / 287.23 | 5 | 93 |
6 | 13 | 213.48 | 20 | 15.00 | 684 | 205 | 4.69 / 287.44 | 6 | 95 |
7 | 8 | -0.04 | 253 | 15.01 | 337 | 1280 | 5.97 / 288.72 | 6 | 132 |
Average= | 5.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 35 | 14.98 | 513 | 269 | 0.27 / 276.99 | 6 | 46 |
2 | 7 | 2003.32 | 40 | 14.64 | 3336 | 1954 | 2.22 / 278.95 | 46 | 67 |
3 | 13 | 1913.84 | 20 | 14.63 | 3216 | 941 | 3.16 / 279.89 | 5 | 73 |
4 | 13 | 1597.24 | 20 | 14.63 | 2762 | 808 | 3.97 / 280.70 | 5 | 80 |
5 | 13 | 835.68 | 20 | 14.81 | 1631 | 483 | 4.45 / 281.18 | 5 | 96 |
6 | 13 | 393.92 | 20 | 14.94 | 949 | 284 | 4.74 / 281.46 | 5 | 100 |
7 | 8 | 0.32 | 259 | 15.01 | 330 | 1283 | 6.02 / 282.75 | 6 | 133 |
Average= | 5.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 35 | 15.00 | 490 | 257 | 0.26 / 270.91 | 6 | 47 |
2 | 7 | 2004.80 | 40 | 14.64 | 3341 | 1956 | 2.21 / 272.87 | 47 | 71 |
3 | 13 | 1918.20 | 20 | 14.63 | 3222 | 943 | 3.16 / 273.81 | 5 | 75 |
4 | 13 | 1504.68 | 20 | 14.66 | 2625 | 770 | 3.93 / 274.58 | 5 | 84 |
5 | 13 | 964.36 | 20 | 14.77 | 1821 | 538 | 4.46 / 275.12 | 5 | 96 |
6 | 13 | 301.72 | 20 | 14.97 | 806 | 241 | 4.71 / 275.36 | 5 | 101 |
7 | 8 | 0.12 | 263 | 15.00 | 346 | 1365 | 6.07 / 276.73 | 6 | 133 |
Average= | 5.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 35 | 15.00 | 496 | 260 | 0.26 / 265.06 | 6 | 46 |
2 | 7 | 2009.40 | 40 | 14.64 | 3343 | 1958 | 2.22 / 267.02 | 46 | 69 |
3 | 13 | 1917.52 | 20 | 14.63 | 3218 | 942 | 3.16 / 267.96 | 5 | 73 |
4 | 13 | 1502.00 | 20 | 14.66 | 2631 | 771 | 3.93 / 268.73 | 5 | 83 |
5 | 13 | 760.72 | 20 | 14.84 | 1503 | 446 | 4.38 / 269.18 | 5 | 97 |
6 | 13 | 135.20 | 20 | 15.04 | 565 | 170 | 4.55 / 269.35 | 6 | 96 |
7 | 8 | 0.08 | 261 | 15.02 | 334 | 1309 | 5.86 / 270.66 | 6 | 137 |
Average= | 5.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 35 | 15.01 | 498 | 262 | 0.26 / 258.91 | 6 | 44 |
2 | 7 | 2005.80 | 40 | 14.65 | 3346 | 1961 | 2.22 / 260.88 | 44 | 68 |
3 | 13 | 1913.88 | 20 | 14.64 | 3224 | 944 | 3.17 / 261.82 | 5 | 73 |
4 | 13 | 1606.44 | 20 | 14.63 | 2793 | 817 | 3.98 / 262.64 | 5 | 81 |
5 | 13 | 954.56 | 20 | 14.78 | 1812 | 536 | 4.52 / 263.17 | 5 | 95 |
6 | 13 | 406.04 | 20 | 14.94 | 970 | 290 | 4.81 / 263.46 | 5 | 100 |
7 | 8 | 0.24 | 261 | 15.02 | 341 | 1337 | 6.15 / 264.80 | 6 | 131 |
Average= | 5.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 34 | 15.01 | 488 | 249 | 0.25 / 253.00 | 6 | 49 |
2 | 3 | 1019.16 | 1 | 15.03 | 1988 | 30 | 0.28 / 253.03 | 5 | 16 |
3 | 7 | 2015.28 | 40 | 14.65 | 3352 | 1964 | 2.24 / 255.00 | 16 | 69 |
4 | 13 | 1927.04 | 20 | 14.64 | 3244 | 950 | 3.19 / 255.95 | 5 | 73 |
5 | 13 | 1399.52 | 20 | 14.69 | 2461 | 723 | 3.92 / 256.67 | 5 | 86 |
6 | 13 | 959.32 | 20 | 14.78 | 1815 | 537 | 4.45 / 257.21 | 5 | 96 |
7 | 13 | 96.00 | 20 | 15.06 | 510 | 154 | 4.61 / 257.36 | 6 | 94 |
8 | 8 | 0.08 | 253 | 15.03 | 340 | 1293 | 5.90 / 258.65 | 6 | 129 |
Average= | 5.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 36 | 15.02 | 494 | 267 | 0.27 / 246.96 | 6 | 46 |
2 | 3 | 955.80 | -1 | 15.40 | 3 | 0 | 0.00 / 246.96 | 6 | 46 |
3 | 7 | 2005.68 | 40 | 14.66 | 3328 | 1952 | 2.22 / 248.91 | 46 | 69 |
4 | 13 | 1916.60 | 20 | 14.64 | 3221 | 943 | 3.16 / 249.86 | 5 | 74 |
5 | 13 | 1488.48 | 20 | 14.68 | 2596 | 762 | 3.92 / 250.62 | 5 | 84 |
6 | 13 | 1066.60 | 20 | 14.75 | 1970 | 581 | 4.51 / 251.20 | 5 | 94 |
7 | 13 | 208.04 | 20 | 15.02 | 659 | 198 | 4.70 / 251.40 | 6 | 98 |
8 | 13 | 19.72 | 20 | 15.07 | 388 | 117 | 4.82 / 251.51 | 6 | 96 |
9 | 8 | -0.20 | 242 | 15.02 | 341 | 1239 | 6.06 / 252.75 | 6 | 135 |
Average= | 5.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 35 | 15.00 | 506 | 266 | 0.27 / 241.01 | 6 | 54 |
2 | 3 | 1018.64 | 1 | 15.05 | 1965 | 30 | 0.30 / 241.04 | 5 | 15 |
3 | 7 | 2012.16 | 41 | 14.65 | 3341 | 2007 | 2.30 / 243.05 | 15 | 70 |
4 | 13 | 1935.28 | 20 | 14.64 | 3230 | 946 | 3.25 / 243.99 | 5 | 74 |
5 | 13 | 1522.52 | 20 | 14.66 | 2659 | 780 | 4.03 / 244.77 | 5 | 84 |
6 | 13 | 879.48 | 20 | 14.82 | 1690 | 501 | 4.53 / 245.27 | 5 | 96 |
7 | 13 | 227.88 | 20 | 15.03 | 692 | 208 | 4.74 / 245.48 | 6 | 97 |
8 | 8 | -0.04 | 246 | 15.04 | 328 | 1214 | 5.95 / 246.69 | 6 | 131 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 35 | 15.04 | 496 | 261 | 0.26 / 234.99 | 6 | 43 |
2 | 7 | 2009.28 | 40 | 14.65 | 3337 | 1955 | 2.22 / 236.94 | 43 | 71 |
3 | 13 | 1916.64 | 20 | 14.65 | 3209 | 940 | 3.16 / 237.88 | 5 | 75 |
4 | 13 | 1481.96 | 20 | 14.67 | 2593 | 761 | 3.92 / 238.65 | 5 | 85 |
5 | 13 | 936.16 | 20 | 14.79 | 1775 | 525 | 4.44 / 239.17 | 5 | 97 |
6 | 13 | 262.72 | 20 | 15.01 | 750 | 225 | 4.67 / 239.40 | 6 | 100 |
7 | 8 | 0.04 | 265 | 15.02 | 339 | 1349 | 6.02 / 240.74 | 6 | 130 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 35 | 15.04 | 498 | 262 | 0.26 / 229.10 | 6 | 44 |
2 | 7 | 2007.48 | 40 | 14.67 | 3327 | 1952 | 2.21 / 231.05 | 44 | 71 |
3 | 13 | 1921.44 | 20 | 14.64 | 3235 | 947 | 3.16 / 232.00 | 6 | 74 |
4 | 13 | 1510.36 | 20 | 14.67 | 2639 | 774 | 3.94 / 232.77 | 5 | 84 |
5 | 13 | 973.80 | 20 | 14.79 | 1822 | 539 | 4.47 / 233.31 | 5 | 96 |
6 | 13 | 323.04 | 20 | 15.00 | 841 | 252 | 4.73 / 233.56 | 6 | 98 |
7 | 8 | 0.04 | 240 | 15.05 | 322 | 1163 | 5.89 / 234.73 | 6 | 132 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 35 | 15.05 | 489 | 258 | 0.26 / 223.05 | 6 | 41 |
2 | 7 | 2013.40 | 40 | 14.66 | 3333 | 1954 | 2.21 / 225.01 | 41 | 69 |
3 | 13 | 1923.32 | 20 | 14.65 | 3206 | 939 | 3.15 / 225.95 | 5 | 72 |
4 | 13 | 1611.00 | 20 | 14.65 | 2779 | 814 | 3.97 / 226.76 | 5 | 81 |
5 | 13 | 1163.84 | 20 | 14.73 | 2115 | 623 | 4.59 / 227.38 | 5 | 90 |
6 | 13 | 267.12 | 20 | 15.03 | 746 | 224 | 4.81 / 227.61 | 6 | 89 |
7 | 8 | 0.12 | 249 | 15.06 | 328 | 1230 | 6.04 / 228.84 | 6 | 133 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 35 | 15.06 | 480 | 253 | 0.25 / 217.21 | 6 | 45 |
2 | 7 | 2017.08 | 40 | 14.66 | 3347 | 1963 | 2.22 / 219.18 | 45 | 70 |
3 | 13 | 1932.72 | 20 | 14.63 | 3235 | 947 | 3.16 / 220.12 | 5 | 74 |
4 | 13 | 1503.20 | 20 | 14.67 | 2622 | 769 | 3.93 / 220.89 | 5 | 85 |
5 | 13 | 1064.08 | 20 | 14.76 | 1963 | 579 | 4.51 / 221.47 | 5 | 93 |
6 | 13 | 100.00 | 20 | 15.09 | 500 | 151 | 4.66 / 221.62 | 6 | 83 |
7 | 8 | 0.00 | 238 | 15.07 | 327 | 1173 | 5.83 / 222.79 | 6 | 132 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 34 | 15.07 | 488 | 250 | 0.25 / 211.51 | 6 | 41 |
2 | 3 | 1031.80 | 1 | 15.10 | 1990 | 30 | 0.28 / 211.54 | 6 | 29 |
3 | 7 | 2005.36 | 40 | 14.67 | 3326 | 1952 | 2.23 / 213.49 | 29 | 68 |
4 | 13 | 1922.04 | 20 | 14.65 | 3216 | 942 | 3.17 / 214.43 | 5 | 74 |
5 | 13 | 1512.68 | 20 | 14.68 | 2623 | 770 | 3.94 / 215.20 | 5 | 83 |
6 | 13 | 778.92 | 20 | 14.87 | 1537 | 457 | 4.40 / 215.66 | 5 | 94 |
7 | 13 | 78.48 | 20 | 15.11 | 452 | 137 | 4.54 / 215.80 | 6 | 82 |
8 | 8 | 0.12 | 240 | 15.07 | 321 | 1161 | 5.70 / 216.96 | 6 | 132 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 37 | 15.09 | 467 | 261 | 0.26 / 205.85 | 6 | 42 |
2 | 3 | 897.12 | -2 | 15.45 | 3 | 0 | 0.00 / 205.85 | 6 | 42 |
3 | 7 | 2008.16 | 40 | 14.68 | 3306 | 1941 | 2.20 / 207.79 | 42 | 70 |
4 | 13 | 1913.24 | 20 | 14.67 | 3162 | 928 | 3.13 / 208.71 | 5 | 74 |
5 | 13 | 1408.72 | 20 | 14.71 | 2477 | 729 | 3.86 / 209.44 | 5 | 84 |
6 | 13 | 978.64 | 20 | 14.81 | 1820 | 539 | 4.40 / 209.98 | 6 | 94 |
7 | 13 | 101.36 | 20 | 15.11 | 497 | 150 | 4.55 / 210.13 | 6 | 78 |
8 | 8 | 0.04 | 233 | 15.08 | 321 | 1128 | 5.68 / 211.26 | 6 | 131 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 35 | 15.03 | 521 | 274 | 0.27 / 200.13 | 6 | 65 |
2 | 3 | 1082.92 | 2 | 15.01 | 2016 | 61 | 0.33 / 200.19 | 5 | 69 |
3 | 7 | 2012.84 | 40 | 14.70 | 3337 | 1962 | 2.30 / 202.15 | 69 | 67 |
4 | 13 | 1926.28 | 20 | 14.68 | 3201 | 940 | 3.24 / 203.09 | 5 | 71 |
5 | 13 | 1516.44 | 20 | 14.72 | 2621 | 772 | 4.01 / 203.86 | 5 | 81 |
6 | 13 | 870.64 | 20 | 14.87 | 1660 | 494 | 4.50 / 204.35 | 5 | 94 |
7 | 13 | 57.64 | 20 | 15.15 | 413 | 125 | 4.63 / 204.48 | 6 | 79 |
8 | 8 | 0.04 | 236 | 15.11 | 310 | 1105 | 5.73 / 205.59 | 6 | 134 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 35 | 15.07 | 494 | 261 | 0.26 / 194.18 | 6 | 45 |
2 | 7 | 2012.72 | 40 | 14.68 | 3346 | 1965 | 2.23 / 196.15 | 6 | 69 |
3 | 13 | 1826.88 | 20 | 14.68 | 3086 | 906 | 3.13 / 197.05 | 5 | 77 |
4 | 13 | 1522.72 | 20 | 14.70 | 2630 | 773 | 3.90 / 197.83 | 5 | 83 |
5 | 13 | 863.84 | 20 | 14.86 | 1665 | 495 | 4.40 / 198.32 | 5 | 97 |
6 | 13 | 112.48 | 20 | 15.10 | 531 | 160 | 4.56 / 198.48 | 6 | 97 |
7 | 8 | 0.24 | 266 | 15.06 | 342 | 1370 | 5.93 / 199.85 | 6 | 134 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 34 | 15.09 | 491 | 252 | 0.25 / 188.18 | 6 | 52 |
2 | 7 | 2011.92 | 40 | 14.69 | 3334 | 1959 | 2.21 / 190.14 | 52 | 71 |
3 | 13 | 1921.84 | 20 | 14.68 | 3224 | 947 | 3.16 / 191.09 | 5 | 73 |
4 | 13 | 1602.80 | 20 | 14.69 | 2762 | 811 | 3.97 / 191.90 | 6 | 81 |
5 | 13 | 1047.84 | 20 | 14.81 | 1936 | 573 | 4.54 / 192.47 | 5 | 93 |
6 | 13 | 282.40 | 20 | 15.05 | 777 | 234 | 4.78 / 192.70 | 6 | 95 |
7 | 8 | 0.24 | 244 | 15.09 | 331 | 1219 | 6.00 / 193.92 | 6 | 132 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 34 | 15.08 | 490 | 251 | 0.25 / 182.44 | 6 | 48 |
2 | 7 | 2005.56 | 40 | 14.69 | 3323 | 1953 | 2.20 / 184.40 | 48 | 69 |
3 | 13 | 1916.60 | 20 | 14.69 | 3205 | 942 | 3.15 / 185.34 | 5 | 73 |
4 | 13 | 1507.56 | 20 | 14.71 | 2609 | 768 | 3.91 / 186.10 | 5 | 84 |
5 | 13 | 872.12 | 20 | 14.87 | 1663 | 495 | 4.41 / 186.60 | 6 | 95 |
6 | 13 | 29.32 | 20 | 15.15 | 388 | 118 | 4.53 / 186.72 | 6 | 81 |
7 | 8 | -0.36 | 246 | 15.10 | 326 | 1211 | 5.74 / 187.93 | 6 | 134 |
Average= | 5.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 34 | 15.09 | 477 | 245 | 0.24 / 176.65 | 6 | 44 |
2 | 7 | 2006.20 | 40 | 14.71 | 3307 | 1946 | 2.19 / 178.60 | 44 | 69 |
3 | 13 | 1911.92 | 20 | 14.70 | 3172 | 933 | 3.12 / 179.53 | 5 | 73 |
4 | 13 | 1476.64 | 20 | 14.74 | 2565 | 756 | 3.88 / 180.29 | 5 | 84 |
5 | 13 | 1032.72 | 20 | 14.82 | 1903 | 564 | 4.44 / 180.85 | 5 | 93 |
6 | 13 | 145.60 | 20 | 15.12 | 558 | 169 | 4.61 / 181.02 | 6 | 89 |
7 | 8 | 0.28 | 240 | 15.10 | 323 | 1171 | 5.78 / 182.19 | 6 | 129 |
Average= | 5.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 35 | 15.10 | 491 | 259 | 0.26 / 170.85 | 6 | 42 |
2 | 7 | 2011.32 | 41 | 14.70 | 3336 | 2011 | 2.27 / 172.86 | 42 | 70 |
3 | 13 | 1919.80 | 20 | 14.69 | 3199 | 940 | 3.21 / 173.80 | 6 | 74 |
4 | 13 | 1492.72 | 20 | 14.74 | 2594 | 765 | 3.97 / 174.57 | 6 | 85 |
5 | 13 | 850.56 | 20 | 14.89 | 1632 | 486 | 4.46 / 175.05 | 6 | 96 |
6 | 13 | 200.28 | 20 | 15.10 | 642 | 194 | 4.65 / 175.25 | 6 | 89 |
7 | 8 | -0.08 | 242 | 15.11 | 318 | 1163 | 5.82 / 176.41 | 6 | 134 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 34 | 15.11 | 492 | 253 | 0.25 / 165.15 | 6 | 47 |
2 | 3 | 1021.40 | 1 | 15.12 | 1973 | 30 | 0.28 / 165.18 | 6 | 13 |
3 | 7 | 2010.16 | 40 | 14.71 | 3322 | 1955 | 2.24 / 167.13 | 13 | 71 |
4 | 13 | 1923.80 | 20 | 14.70 | 3208 | 943 | 3.18 / 168.08 | 5 | 74 |
5 | 13 | 1393.72 | 20 | 14.77 | 2449 | 723 | 3.90 / 168.80 | 5 | 84 |
6 | 13 | 856.36 | 20 | 14.89 | 1647 | 490 | 4.39 / 169.29 | 6 | 96 |
7 | 13 | 48.32 | 20 | 15.16 | 414 | 126 | 4.52 / 169.42 | 6 | 80 |
8 | 8 | 0.12 | 240 | 15.12 | 324 | 1176 | 5.70 / 170.59 | 6 | 132 |
Average= | 5.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 34 | 15.10 | 486 | 250 | 0.25 / 159.44 | 6 | 47 |
2 | 7 | 2008.12 | 40 | 14.73 | 3302 | 1946 | 2.20 / 161.38 | 47 | 70 |
3 | 13 | 1917.80 | 20 | 14.71 | 3176 | 934 | 3.13 / 162.32 | 5 | 74 |
4 | 13 | 1495.28 | 20 | 14.75 | 2586 | 763 | 3.89 / 163.08 | 5 | 83 |
5 | 13 | 850.64 | 20 | 14.90 | 1643 | 490 | 4.38 / 163.57 | 5 | 95 |
6 | 13 | 107.28 | 20 | 15.15 | 504 | 153 | 4.53 / 163.72 | 6 | 84 |
7 | 8 | 0.16 | 238 | 15.13 | 326 | 1174 | 5.71 / 164.90 | 6 | 135 |
Average= | 5.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 34 | 15.11 | 493 | 253 | 0.25 / 153.75 | 6 | 44 |
2 | 7 | 2004.76 | 41 | 14.72 | 3296 | 1989 | 2.24 / 155.74 | 44 | 69 |
3 | 13 | 1913.28 | 20 | 14.71 | 3194 | 940 | 3.18 / 156.68 | 5 | 74 |
4 | 13 | 1383.40 | 20 | 14.79 | 2414 | 714 | 3.90 / 157.40 | 5 | 85 |
5 | 13 | 838.96 | 20 | 14.91 | 1614 | 481 | 4.38 / 157.88 | 6 | 96 |
6 | 13 | 42.96 | 20 | 15.16 | 413 | 125 | 4.50 / 158.00 | 6 | 85 |
7 | 8 | 0.28 | 238 | 15.12 | 329 | 1184 | 5.69 / 159.19 | 6 | 132 |
Average= | 5.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 34 | 15.13 | 467 | 240 | 0.24 / 148.01 | 6 | 38 |
2 | 7 | 2005.52 | 40 | 14.73 | 3301 | 1945 | 2.19 / 149.95 | 38 | 70 |
3 | 13 | 1914.24 | 20 | 14.74 | 3171 | 935 | 3.12 / 150.89 | 5 | 73 |
4 | 13 | 1479.56 | 20 | 14.77 | 2565 | 758 | 3.88 / 151.64 | 5 | 84 |
5 | 13 | 937.04 | 20 | 14.88 | 1751 | 521 | 4.40 / 152.16 | 5 | 93 |
6 | 13 | 163.64 | 20 | 15.13 | 598 | 181 | 4.58 / 152.34 | 6 | 89 |
7 | 8 | -0.04 | 238 | 15.13 | 321 | 1156 | 5.74 / 153.50 | 6 | 129 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 34 | 15.14 | 477 | 246 | 0.25 / 142.38 | 6 | 34 |
2 | 7 | 2005.16 | 40 | 14.72 | 3291 | 1938 | 2.18 / 144.32 | 34 | 69 |
3 | 13 | 1914.56 | 20 | 14.72 | 3153 | 928 | 3.11 / 145.24 | 5 | 72 |
4 | 13 | 1482.56 | 20 | 14.77 | 2564 | 757 | 3.87 / 146.00 | 5 | 83 |
5 | 13 | 827.48 | 20 | 14.92 | 1588 | 474 | 4.34 / 146.48 | 5 | 96 |
6 | 13 | 169.24 | 20 | 15.14 | 594 | 180 | 4.52 / 146.66 | 6 | 84 |
7 | 8 | -0.16 | 235 | 15.14 | 312 | 1110 | 5.63 / 147.77 | 6 | 137 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 34 | 15.14 | 467 | 240 | 0.24 / 136.78 | 6 | 36 |
2 | 7 | 2004.68 | 40 | 14.74 | 3297 | 1944 | 2.18 / 138.73 | 36 | 69 |
3 | 13 | 1912.52 | 20 | 14.74 | 3171 | 935 | 3.12 / 139.66 | 5 | 72 |
4 | 13 | 1388.96 | 20 | 14.80 | 2442 | 723 | 3.84 / 140.38 | 5 | 85 |
5 | 13 | 951.60 | 20 | 14.89 | 1785 | 532 | 4.37 / 140.92 | 5 | 93 |
6 | 13 | 102.16 | 20 | 15.17 | 483 | 147 | 4.52 / 141.06 | 6 | 79 |
7 | 8 | 0.12 | 227 | 15.15 | 311 | 1070 | 5.59 / 142.13 | 6 | 132 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 34 | 15.14 | 482 | 248 | 0.25 / 131.13 | 6 | 38 |
2 | 7 | 2003.52 | 40 | 14.74 | 3291 | 1940 | 2.19 / 133.07 | 38 | 71 |
3 | 13 | 1911.36 | 20 | 14.74 | 3164 | 933 | 3.12 / 134.00 | 5 | 74 |
4 | 13 | 1392.60 | 20 | 14.79 | 2445 | 723 | 3.84 / 134.73 | 5 | 85 |
5 | 13 | 859.52 | 20 | 14.91 | 1651 | 492 | 4.34 / 135.22 | 5 | 96 |
6 | 13 | 188.56 | 20 | 15.14 | 628 | 190 | 4.53 / 135.41 | 6 | 88 |
7 | 8 | -0.04 | 238 | 15.14 | 315 | 1135 | 5.66 / 136.54 | 6 | 132 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 34 | 15.15 | 482 | 248 | 0.25 / 125.46 | 6 | 38 |
2 | 7 | 2005.52 | 40 | 14.73 | 3328 | 1961 | 2.21 / 127.42 | 38 | 71 |
3 | 13 | 1915.16 | 20 | 14.72 | 3197 | 941 | 3.15 / 128.36 | 5 | 75 |
4 | 13 | 1384.64 | 20 | 14.81 | 2428 | 719 | 3.87 / 129.08 | 5 | 87 |
5 | 13 | 950.24 | 20 | 14.89 | 1788 | 532 | 4.40 / 129.61 | 5 | 96 |
6 | 13 | 90.76 | 20 | 15.18 | 483 | 147 | 4.55 / 129.76 | 6 | 82 |
7 | 8 | 0.20 | 233 | 15.15 | 318 | 1123 | 5.67 / 130.88 | 6 | 134 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 34 | 15.16 | 466 | 240 | 0.24 / 119.81 | 6 | 34 |
2 | 7 | 2008.84 | 40 | 14.75 | 3312 | 1954 | 2.19 / 121.76 | 34 | 70 |
3 | 13 | 1914.84 | 20 | 14.75 | 3160 | 932 | 3.13 / 122.69 | 6 | 74 |
4 | 13 | 1481.84 | 20 | 14.79 | 2568 | 760 | 3.89 / 123.45 | 5 | 84 |
5 | 13 | 943.48 | 20 | 14.90 | 1773 | 528 | 4.41 / 123.98 | 6 | 95 |
6 | 13 | 80.48 | 20 | 15.19 | 454 | 138 | 4.55 / 124.12 | 6 | 81 |
7 | 8 | 0.00 | 229 | 15.16 | 314 | 1090 | 5.64 / 125.21 | 6 | 132 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 34 | 15.16 | 461 | 238 | 0.24 / 114.26 | 6 | 33 |
2 | 7 | 2003.68 | 40 | 14.75 | 3296 | 1945 | 2.18 / 116.20 | 33 | 71 |
3 | 13 | 1907.88 | 20 | 14.75 | 3160 | 932 | 3.11 / 117.14 | 5 | 76 |
4 | 13 | 1383.88 | 20 | 14.81 | 2431 | 720 | 3.83 / 117.86 | 5 | 87 |
5 | 13 | 853.92 | 20 | 14.93 | 1636 | 489 | 4.32 / 118.34 | 5 | 97 |
6 | 13 | 95.52 | 20 | 15.19 | 481 | 146 | 4.47 / 118.49 | 6 | 82 |
7 | 8 | -0.08 | 227 | 15.16 | 313 | 1077 | 5.55 / 119.57 | 6 | 129 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 35 | 15.15 | 462 | 245 | 0.24 / 108.60 | 6 | 37 |
2 | 7 | 2003.36 | 40 | 14.75 | 3309 | 1952 | 2.20 / 110.55 | 37 | 72 |
3 | 13 | 1911.44 | 20 | 14.75 | 3180 | 938 | 3.14 / 111.49 | 5 | 76 |
4 | 13 | 1489.84 | 20 | 14.79 | 2576 | 762 | 3.90 / 112.25 | 5 | 85 |
5 | 13 | 936.20 | 20 | 14.91 | 1756 | 524 | 4.42 / 112.78 | 5 | 96 |
6 | 13 | 75.68 | 20 | 15.20 | 453 | 138 | 4.56 / 112.91 | 6 | 81 |
7 | 8 | 0.16 | 231 | 15.17 | 316 | 1107 | 5.67 / 114.02 | 6 | 132 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 34 | 15.17 | 460 | 237 | 0.24 / 102.90 | 6 | 31 |
2 | 7 | 2005.60 | 40 | 14.75 | 3309 | 1952 | 2.19 / 104.86 | 8 | 71 |
3 | 13 | 1916.80 | 20 | 14.75 | 3165 | 934 | 3.12 / 105.79 | 5 | 75 |
4 | 13 | 1482.24 | 20 | 14.80 | 2558 | 757 | 3.88 / 106.55 | 5 | 85 |
5 | 13 | 829.44 | 20 | 14.95 | 1599 | 478 | 4.36 / 107.03 | 5 | 95 |
6 | 13 | 174.00 | 20 | 15.17 | 601 | 182 | 4.54 / 107.21 | 6 | 84 |
7 | 8 | 0.20 | 240 | 15.17 | 315 | 1147 | 5.69 / 108.35 | 6 | 159 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 34 | 15.18 | 461 | 238 | 0.24 / 97.26 | 6 | 31 |
2 | 7 | 2003.40 | 40 | 14.77 | 3306 | 1953 | 2.19 / 99.22 | 31 | 71 |
3 | 13 | 1907.76 | 20 | 14.77 | 3157 | 933 | 3.12 / 100.15 | 5 | 74 |
4 | 13 | 1394.64 | 20 | 14.83 | 2445 | 725 | 3.85 / 100.87 | 5 | 86 |
5 | 13 | 961.08 | 20 | 14.91 | 1799 | 536 | 4.39 / 101.41 | 5 | 94 |
6 | 13 | 175.44 | 20 | 15.18 | 607 | 184 | 4.57 / 101.59 | 6 | 81 |
7 | 8 | 0.08 | 234 | 15.19 | 302 | 1073 | 5.64 / 102.67 | 6 | 142 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 34 | 15.18 | 469 | 242 | 0.24 / 91.64 | 6 | 33 |
2 | 7 | 2005.24 | 40 | 14.77 | 3310 | 1956 | 2.20 / 93.60 | 33 | 72 |
3 | 13 | 1911.04 | 20 | 14.76 | 3179 | 938 | 3.14 / 94.54 | 5 | 76 |
4 | 13 | 1481.88 | 20 | 14.81 | 2563 | 759 | 3.90 / 95.30 | 5 | 85 |
5 | 13 | 829.96 | 20 | 14.97 | 1595 | 478 | 4.37 / 95.77 | 5 | 96 |
6 | 13 | 80.64 | 20 | 15.21 | 456 | 139 | 4.51 / 95.91 | 6 | 80 |
7 | 8 | 0.24 | 234 | 15.18 | 313 | 1112 | 5.62 / 97.02 | 6 | 148 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 34 | 15.18 | 472 | 244 | 0.24 / 86.03 | 6 | 29 |
2 | 7 | 2004.20 | 40 | 14.78 | 3298 | 1950 | 2.19 / 87.98 | 29 | 69 |
3 | 13 | 1914.36 | 20 | 14.78 | 3167 | 936 | 3.13 / 88.92 | 5 | 74 |
4 | 13 | 1393.12 | 20 | 14.84 | 2433 | 722 | 3.85 / 89.64 | 5 | 86 |
5 | 13 | 955.52 | 20 | 14.93 | 1784 | 533 | 4.38 / 90.18 | 5 | 95 |
6 | 13 | 87.92 | 20 | 15.21 | 467 | 142 | 4.53 / 90.32 | 6 | 80 |
7 | 8 | 0.32 | 225 | 15.19 | 317 | 1083 | 5.61 / 91.40 | 6 | 133 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 34 | 15.18 | 471 | 243 | 0.24 / 80.42 | 6 | 31 |
2 | 7 | 2006.76 | 40 | 14.79 | 3303 | 1954 | 2.20 / 82.38 | 31 | 72 |
3 | 13 | 1915.60 | 20 | 14.78 | 3200 | 946 | 3.14 / 83.32 | 5 | 76 |
4 | 13 | 1482.56 | 20 | 14.83 | 2551 | 757 | 3.90 / 84.08 | 5 | 85 |
5 | 13 | 840.76 | 20 | 14.97 | 1607 | 481 | 4.38 / 84.56 | 5 | 96 |
6 | 13 | 169.60 | 20 | 15.19 | 590 | 179 | 4.56 / 84.74 | 6 | 85 |
7 | 8 | 0.00 | 225 | 15.19 | 308 | 1053 | 5.61 / 85.79 | 6 | 131 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 34 | 15.19 | 473 | 244 | 0.24 / 74.79 | 6 | 33 |
2 | 7 | 2005.88 | 40 | 14.78 | 3294 | 1947 | 2.19 / 76.74 | 33 | 73 |
3 | 13 | 1913.24 | 20 | 14.79 | 3174 | 939 | 3.13 / 77.68 | 5 | 77 |
4 | 13 | 1383.76 | 20 | 14.85 | 2423 | 720 | 3.85 / 78.40 | 5 | 89 |
5 | 13 | 945.08 | 20 | 14.93 | 1786 | 533 | 4.38 / 78.93 | 5 | 97 |
6 | 13 | 79.04 | 20 | 15.22 | 452 | 138 | 4.52 / 79.07 | 6 | 83 |
7 | 8 | 0.16 | 233 | 15.19 | 313 | 1108 | 5.63 / 80.18 | 6 | 133 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 34 | 15.19 | 452 | 233 | 0.23 / 69.19 | 6 | 31 |
2 | 7 | 2006.36 | 40 | 14.79 | 3303 | 1954 | 2.19 / 71.15 | 31 | 73 |
3 | 13 | 1915.56 | 20 | 14.79 | 3165 | 936 | 3.12 / 72.08 | 5 | 77 |
4 | 13 | 1489.72 | 20 | 14.83 | 2564 | 760 | 3.88 / 72.84 | 5 | 86 |
5 | 13 | 817.56 | 20 | 14.98 | 1574 | 472 | 4.36 / 73.32 | 5 | 97 |
6 | 13 | 67.92 | 20 | 15.23 | 432 | 132 | 4.49 / 73.45 | 6 | 82 |
7 | 8 | -0.04 | 233 | 15.20 | 311 | 1101 | 5.59 / 74.55 | 6 | 136 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 34 | 15.19 | 482 | 249 | 0.25 / 63.67 | 6 | 32 |
2 | 7 | 2004.48 | 40 | 14.80 | 3280 | 1942 | 2.19 / 65.61 | 32 | 72 |
3 | 13 | 1908.28 | 20 | 14.80 | 3162 | 936 | 3.13 / 66.55 | 5 | 76 |
4 | 13 | 1375.44 | 20 | 14.86 | 2409 | 716 | 3.84 / 67.26 | 5 | 88 |
5 | 13 | 829.12 | 20 | 14.99 | 1586 | 475 | 4.32 / 67.74 | 5 | 97 |
6 | 13 | 42.36 | 20 | 15.24 | 392 | 119 | 4.44 / 67.86 | 6 | 83 |
7 | 8 | 0.04 | 231 | 15.20 | 314 | 1103 | 5.54 / 68.96 | 6 | 138 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 34 | 15.20 | 476 | 246 | 0.25 / 58.04 | 6 | 36 |
2 | 7 | 2013.16 | 40 | 14.80 | 3311 | 1960 | 2.21 / 60.00 | 36 | 73 |
3 | 13 | 1917.00 | 20 | 14.79 | 3183 | 942 | 3.15 / 60.95 | 5 | 77 |
4 | 13 | 1377.56 | 20 | 14.87 | 2422 | 720 | 3.87 / 61.67 | 5 | 89 |
5 | 13 | 839.72 | 20 | 14.98 | 1603 | 480 | 4.35 / 62.15 | 5 | 97 |
6 | 13 | 77.72 | 20 | 15.23 | 458 | 140 | 4.49 / 62.29 | 6 | 82 |
7 | 8 | -0.04 | 231 | 15.20 | 323 | 1134 | 5.62 / 63.42 | 6 | 131 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 34 | 15.20 | 482 | 249 | 0.25 / 52.52 | 6 | 35 |
2 | 7 | 2004.36 | 40 | 14.81 | 3293 | 1951 | 2.20 / 54.47 | 35 | 73 |
3 | 13 | 1908.32 | 20 | 14.82 | 3151 | 934 | 3.13 / 55.41 | 6 | 76 |
4 | 13 | 1375.92 | 20 | 14.87 | 2424 | 721 | 3.85 / 56.13 | 5 | 88 |
5 | 13 | 746.76 | 20 | 15.03 | 1458 | 438 | 4.29 / 56.57 | 5 | 97 |
6 | 13 | 88.24 | 20 | 15.24 | 465 | 142 | 4.43 / 56.71 | 6 | 81 |
7 | 8 | 0.16 | 231 | 15.21 | 310 | 1089 | 5.52 / 57.80 | 6 | 139 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 34 | 15.21 | 477 | 247 | 0.25 / 46.96 | 6 | 29 |
2 | 7 | 2004.64 | 40 | 14.83 | 3274 | 1942 | 2.19 / 48.90 | 10 | 72 |
3 | 13 | 1906.36 | 20 | 14.82 | 3155 | 935 | 3.12 / 49.83 | 6 | 76 |
4 | 13 | 1374.76 | 20 | 14.88 | 2408 | 717 | 3.84 / 50.55 | 5 | 88 |
5 | 13 | 829.84 | 20 | 15.00 | 1592 | 478 | 4.32 / 51.03 | 6 | 97 |
6 | 13 | 70.88 | 20 | 15.25 | 441 | 135 | 4.45 / 51.16 | 6 | 81 |
7 | 8 | 0.12 | 229 | 15.21 | 319 | 1111 | 5.56 / 52.27 | 6 | 131 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 34 | 15.22 | 477 | 247 | 0.25 / 41.36 | 6 | 34 |
2 | 7 | 2003.80 | 41 | 14.82 | 3280 | 1993 | 2.24 / 43.35 | 34 | 72 |
3 | 13 | 1906.24 | 20 | 14.83 | 3155 | 936 | 3.18 / 44.29 | 5 | 77 |
4 | 13 | 1369.36 | 20 | 14.88 | 2395 | 713 | 3.89 / 45.00 | 5 | 89 |
5 | 13 | 838.16 | 20 | 15.00 | 1609 | 483 | 4.37 / 45.48 | 5 | 97 |
6 | 13 | 78.20 | 20 | 15.25 | 452 | 138 | 4.51 / 45.62 | 6 | 83 |
7 | 8 | 0.20 | 227 | 15.22 | 315 | 1088 | 5.60 / 46.71 | 6 | 135 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 34 | 15.21 | 483 | 250 | 0.25 / 35.73 | 6 | 36 |
2 | 7 | 2004.64 | 40 | 14.83 | 3295 | 1955 | 2.20 / 37.69 | 36 | 72 |
3 | 13 | 1913.68 | 20 | 14.83 | 3173 | 941 | 3.15 / 38.63 | 5 | 76 |
4 | 13 | 1473.00 | 20 | 14.87 | 2545 | 757 | 3.90 / 39.39 | 5 | 87 |
5 | 13 | 826.96 | 20 | 15.01 | 1585 | 476 | 4.38 / 39.86 | 6 | 97 |
6 | 13 | 81.20 | 20 | 15.25 | 459 | 140 | 4.52 / 40.00 | 6 | 81 |
7 | 8 | 0.00 | 229 | 15.22 | 319 | 1112 | 5.63 / 41.11 | 6 | 135 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 33 | 15.22 | 506 | 254 | 0.25 / 30.07 | 6 | 42 |
2 | 7 | 2004.24 | 40 | 14.82 | 3312 | 1963 | 2.22 / 32.04 | 16 | 74 |
3 | 13 | 1909.88 | 20 | 14.82 | 3191 | 946 | 3.16 / 32.98 | 6 | 78 |
4 | 13 | 1472.84 | 20 | 14.87 | 2557 | 760 | 3.92 / 33.74 | 6 | 88 |
5 | 13 | 821.92 | 20 | 15.02 | 1597 | 480 | 4.40 / 34.22 | 6 | 98 |
6 | 13 | 33.56 | 20 | 15.27 | 399 | 122 | 4.53 / 34.34 | 6 | 82 |
7 | 8 | 0.00 | 229 | 15.23 | 327 | 1140 | 5.67 / 35.48 | 6 | 137 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 33 | 15.22 | 485 | 244 | 0.24 / 24.33 | 6 | 39 |
2 | 3 | 1020.72 | 1 | 15.22 | 1949 | 30 | 0.27 / 24.36 | 6 | 35 |
3 | 7 | 2004.24 | 41 | 14.82 | 3313 | 2013 | 2.29 / 26.37 | 35 | 74 |
4 | 13 | 1910.68 | 20 | 14.83 | 3185 | 945 | 3.23 / 27.32 | 6 | 79 |
5 | 13 | 1479.92 | 20 | 14.86 | 2559 | 761 | 3.99 / 28.08 | 5 | 89 |
6 | 13 | 809.56 | 20 | 15.03 | 1567 | 471 | 4.46 / 28.55 | 6 | 98 |
7 | 13 | 29.88 | 20 | 15.27 | 393 | 120 | 4.58 / 28.67 | 6 | 80 |
8 | 8 | 0.08 | 229 | 15.23 | 329 | 1147 | 5.73 / 29.82 | 6 | 137 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 31 | 15.24 | 492 | 232 | 0.23 / 18.67 | 6 | 41 |
2 | 3 | 1078.08 | 2 | 15.18 | 2010 | 61 | 0.29 / 18.73 | 6 | 76 |
3 | 7 | 2005.24 | 40 | 14.83 | 3310 | 1963 | 2.26 / 20.69 | 76 | 74 |
4 | 13 | 1909.48 | 20 | 14.84 | 3181 | 944 | 3.20 / 21.63 | 5 | 78 |
5 | 13 | 1372.60 | 20 | 14.89 | 2414 | 719 | 3.92 / 22.35 | 5 | 91 |
6 | 13 | 835.32 | 20 | 15.02 | 1601 | 481 | 4.40 / 22.83 | 5 | 98 |
7 | 13 | 36.48 | 20 | 15.28 | 395 | 121 | 4.52 / 22.95 | 6 | 83 |
8 | 8 | -0.08 | 229 | 15.23 | 325 | 1133 | 5.66 / 24.09 | 6 | 135 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 32 | 15.24 | 475 | 232 | 0.23 / 13.86 | 6 | 41 |
2 | 7 | 1513.08 | 40 | 15.01 | 2589 | 1554 | 1.79 / 15.41 | 20 | 79 |
3 | 13 | 1441.52 | 20 | 15.00 | 2498 | 749 | 2.54 / 16.16 | 5 | 84 |
4 | 13 | 1246.52 | 20 | 14.99 | 2216 | 664 | 3.20 / 16.83 | 5 | 88 |
5 | 13 | 682.56 | 20 | 15.11 | 1378 | 416 | 3.62 / 17.25 | 6 | 95 |
6 | 8 | 0.16 | 244 | 15.26 | 319 | 1188 | 4.80 / 18.43 | 6 | 138 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 32 | 15.24 | 473 | 231 | 0.23 / 9.17 | 6 | 40 |
2 | 7 | 1521.08 | 40 | 15.00 | 2597 | 1558 | 1.79 / 10.73 | 40 | 81 |
3 | 13 | 1453.88 | 20 | 14.99 | 2522 | 756 | 2.54 / 11.48 | 5 | 85 |
4 | 13 | 1158.64 | 20 | 15.01 | 2083 | 625 | 3.17 / 12.11 | 5 | 92 |
5 | 13 | 618.72 | 20 | 15.13 | 1279 | 387 | 3.56 / 12.50 | 6 | 97 |
6 | 8 | 0.12 | 242 | 15.26 | 307 | 1134 | 4.69 / 13.63 | 6 | 131 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 31 | 15.27 | 478 | 226 | 0.23 / 4.45 | 6 | 40 |
2 | 3 | 1051.92 | 1 | 15.23 | 1974 | 30 | 0.26 / 4.48 | 6 | 79 |
3 | 7 | 1507.64 | 40 | 15.00 | 2582 | 1549 | 1.81 / 6.03 | 79 | 81 |
4 | 13 | 1434.96 | 20 | 14.99 | 2493 | 747 | 2.55 / 6.78 | 5 | 86 |
5 | 13 | 1238.24 | 20 | 14.98 | 2205 | 661 | 3.21 / 7.44 | 5 | 91 |
6 | 13 | 576.52 | 20 | 15.14 | 1218 | 369 | 3.58 / 7.81 | 6 | 96 |
7 | 8 | 0.16 | 242 | 15.26 | 306 | 1130 | 4.71 / 8.94 | 6 | 130 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 31 | 15.43 | 454 | 217 | 0.22 / 1.78 | 6 | 37 |
2 | 3 | 1034.20 | 1 | 15.24 | 1952 | 30 | 0.25 / 1.81 | 6 | 80 |
3 | 7 | 1013.40 | 40 | 15.12 | 1851 | 1119 | 1.37 / 2.93 | 80 | 89 |
4 | 13 | 170.16 | 20 | 15.33 | 585 | 179 | 1.55 / 3.11 | 6 | 82 |
5 | 8 | 0.12 | 240 | 15.32 | 304 | 1118 | 2.66 / 4.23 | 6 | 142 |
Average= | 2.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 92.84 | 30 | 15.57 | 447 | 209 | 0.21 / 0.21 | 6 | 51 |
2 | 7 | 102.92 | 40 | 15.55 | 461 | 287 | 0.50 / 0.50 | 51 | 58 |
3 | 13 | 26.16 | 20 | 15.55 | 337 | 105 | 0.60 / 0.60 | 6 | 58 |
4 | 8 | 0.04 | 216 | 15.51 | 287 | 961 | 1.56 / 1.56 | 6 | 141 |
Average= | 1.56 (KJ/cycle) |