SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 30 | 15.06 | 469 | 212 | 0.21 / 793.15 | 2 | 3 |
2 | 7 | 2003.28 | 53 | 15.02 | 3102 | 2469 | 2.68 / 795.62 | 2 | 3 |
3 | 13 | 1025.96 | 16 | 14.96 | 1803 | 432 | 3.11 / 796.05 | 2 | 4 |
4 | 13 | 465.84 | 16 | 15.05 | 1021 | 246 | 3.36 / 796.30 | 2 | 4 |
5 | 13 | 82.56 | 16 | 15.14 | 451 | 109 | 3.47 / 796.40 | 2 | 6 |
6 | 8 | 0.00 | 165 | 15.11 | 305 | 760 | 4.23 / 797.16 | 2 | 3 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 30 | 15.06 | 496 | 224 | 0.22 / 788.89 | 2 | 3 |
2 | 7 | 2003.12 | 53 | 15.01 | 3112 | 2476 | 2.70 / 791.36 | 2 | 3 |
3 | 13 | 1032.80 | 16 | 14.96 | 1809 | 433 | 3.13 / 791.80 | 2 | 4 |
4 | 13 | 477.08 | 16 | 15.05 | 1039 | 250 | 3.38 / 792.05 | 2 | 4 |
5 | 13 | 87.32 | 16 | 15.13 | 460 | 111 | 3.49 / 792.16 | 2 | 5 |
6 | 8 | 0.12 | 165 | 15.11 | 312 | 778 | 4.27 / 792.94 | 2 | 7 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 30 | 15.06 | 490 | 221 | 0.22 / 784.64 | 2 | 2 |
2 | 7 | 2003.52 | 53 | 15.01 | 3109 | 2473 | 2.69 / 787.11 | 2 | 3 |
3 | 13 | 1018.84 | 16 | 14.96 | 1798 | 430 | 3.13 / 787.54 | 2 | 3 |
4 | 13 | 463.68 | 16 | 15.06 | 1020 | 246 | 3.37 / 787.79 | 2 | 4 |
5 | 13 | 82.80 | 16 | 15.13 | 450 | 109 | 3.48 / 787.90 | 2 | 5 |
6 | 8 | -0.32 | 165 | 15.11 | 307 | 765 | 4.25 / 788.66 | 2 | 11 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 30 | 15.05 | 472 | 213 | 0.21 / 780.35 | 2 | 2 |
2 | 7 | 2011.56 | 53 | 15.03 | 3142 | 2503 | 2.72 / 782.85 | 2 | 3 |
3 | 13 | 1022.48 | 16 | 14.97 | 1801 | 431 | 3.15 / 783.29 | 2 | 4 |
4 | 13 | 460.92 | 16 | 15.06 | 1013 | 244 | 3.39 / 783.53 | 2 | 4 |
5 | 13 | 77.52 | 16 | 15.15 | 447 | 108 | 3.50 / 783.64 | 2 | 3 |
6 | 8 | 0.32 | 165 | 15.12 | 313 | 781 | 4.28 / 784.42 | 2 | 6 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 30 | 15.07 | 494 | 223 | 0.22 / 775.76 | 2 | 3 |
2 | 7 | 2007.92 | 53 | 15.03 | 3125 | 2489 | 2.71 / 778.25 | 2 | 3 |
3 | 13 | 1028.64 | 16 | 14.97 | 1810 | 434 | 3.15 / 778.68 | 2 | 4 |
4 | 13 | 457.64 | 16 | 15.07 | 1006 | 243 | 3.39 / 778.92 | 2 | 4 |
5 | 13 | 72.76 | 16 | 15.16 | 434 | 105 | 3.49 / 779.03 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.13 | 307 | 766 | 4.26 / 779.79 | 2 | 3 |
7 | 14 | -0.04 | 75 | 15.09 | 304 | 344 | 4.60 / 780.14 | 4 | 10 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 30 | 15.07 | 500 | 226 | 0.23 / 771.55 | 2 | 2 |
2 | 7 | 2002.80 | 52 | 15.03 | 3107 | 2428 | 2.65 / 773.97 | 2 | 2 |
3 | 13 | 1024.48 | 16 | 14.97 | 1809 | 433 | 3.09 / 774.41 | 2 | 5 |
4 | 13 | 465.20 | 16 | 15.06 | 1021 | 246 | 3.33 / 774.65 | 2 | 4 |
5 | 13 | 74.56 | 16 | 15.15 | 440 | 107 | 3.44 / 774.76 | 2 | 5 |
6 | 8 | 0.16 | 165 | 15.13 | 310 | 774 | 4.21 / 775.53 | 2 | 9 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.84 | 30 | 15.05 | 501 | 226 | 0.23 / 767.25 | 2 | 3 |
2 | 7 | 2012.00 | 53 | 15.03 | 3145 | 2505 | 2.73 / 769.75 | 2 | 3 |
3 | 13 | 1015.16 | 16 | 14.99 | 1790 | 429 | 3.16 / 770.18 | 2 | 4 |
4 | 13 | 461.56 | 16 | 15.08 | 1012 | 244 | 3.40 / 770.43 | 2 | 4 |
5 | 13 | 78.72 | 16 | 15.15 | 445 | 108 | 3.51 / 770.54 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.13 | 314 | 784 | 4.30 / 771.32 | 2 | 5 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.20 | 30 | 15.08 | 508 | 230 | 0.23 / 762.64 | 2 | 2 |
2 | 7 | 2003.16 | 53 | 15.03 | 3102 | 2471 | 2.70 / 765.11 | 2 | 3 |
3 | 13 | 1020.76 | 16 | 14.97 | 1801 | 431 | 3.13 / 765.54 | 2 | 5 |
4 | 13 | 459.12 | 16 | 15.07 | 1012 | 244 | 3.38 / 765.79 | 2 | 4 |
5 | 13 | 73.28 | 16 | 15.15 | 438 | 106 | 3.48 / 765.89 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.12 | 313 | 781 | 4.26 / 766.67 | 2 | 5 |
7 | 14 | -0.08 | 75 | 15.09 | 309 | 350 | 4.61 / 767.02 | 2 | 11 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 31 | 15.07 | 498 | 233 | 0.23 / 758.40 | 2 | 3 |
2 | 7 | 2003.08 | 53 | 15.04 | 3110 | 2479 | 2.71 / 760.88 | 2 | 2 |
3 | 13 | 913.32 | 16 | 15.01 | 1652 | 397 | 3.11 / 761.28 | 2 | 4 |
4 | 13 | 502.76 | 16 | 15.06 | 1078 | 260 | 3.37 / 761.54 | 2 | 4 |
5 | 13 | 46.88 | 16 | 15.16 | 392 | 95 | 3.46 / 761.63 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.13 | 312 | 779 | 4.24 / 762.41 | 2 | 10 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 31 | 15.08 | 474 | 222 | 0.22 / 754.12 | 2 | 3 |
2 | 7 | 2007.36 | 53 | 15.03 | 3122 | 2487 | 2.71 / 756.60 | 2 | 3 |
3 | 13 | 1029.56 | 16 | 14.98 | 1811 | 434 | 3.14 / 757.04 | 2 | 4 |
4 | 13 | 471.52 | 16 | 15.07 | 1029 | 248 | 3.39 / 757.29 | 2 | 3 |
5 | 13 | 78.44 | 16 | 15.16 | 443 | 107 | 3.50 / 757.39 | 2 | 5 |
6 | 8 | 0.04 | 165 | 15.13 | 310 | 774 | 4.27 / 758.17 | 2 | 9 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.08 | 31 | 15.08 | 485 | 227 | 0.23 / 749.86 | 2 | 3 |
2 | 7 | 2013.44 | 53 | 15.02 | 3105 | 2472 | 2.70 / 752.33 | 2 | 3 |
3 | 13 | 1031.16 | 16 | 14.98 | 1812 | 434 | 3.13 / 752.77 | 2 | 4 |
4 | 13 | 473.92 | 16 | 15.07 | 1034 | 249 | 3.38 / 753.01 | 2 | 4 |
5 | 13 | 89.16 | 16 | 15.15 | 464 | 112 | 3.49 / 753.13 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.12 | 308 | 768 | 4.26 / 753.90 | 2 | 8 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 30 | 15.06 | 498 | 225 | 0.22 / 745.57 | 2 | 3 |
2 | 7 | 2003.12 | 53 | 15.04 | 3110 | 2479 | 2.70 / 748.05 | 2 | 3 |
3 | 13 | 1015.72 | 16 | 14.98 | 1790 | 429 | 3.13 / 748.48 | 2 | 4 |
4 | 13 | 576.60 | 16 | 15.05 | 1177 | 283 | 3.42 / 748.76 | 2 | 4 |
5 | 13 | 64.84 | 16 | 15.16 | 418 | 101 | 3.52 / 748.87 | 2 | 6 |
6 | 8 | 0.16 | 165 | 15.14 | 307 | 767 | 4.28 / 749.63 | 2 | 4 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 30 | 15.08 | 490 | 222 | 0.22 / 741.26 | 2 | 3 |
2 | 7 | 2010.32 | 53 | 15.03 | 3114 | 2481 | 2.70 / 743.74 | 2 | 3 |
3 | 13 | 1016.00 | 16 | 14.97 | 1789 | 429 | 3.13 / 744.17 | 2 | 3 |
4 | 13 | 576.48 | 16 | 15.02 | 1177 | 283 | 3.41 / 744.45 | 2 | 4 |
5 | 13 | 123.64 | 16 | 15.13 | 515 | 125 | 3.54 / 744.58 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.11 | 309 | 770 | 4.31 / 745.35 | 2 | 6 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.12 | 30 | 15.07 | 507 | 229 | 0.23 / 737.03 | 2 | 3 |
2 | 7 | 2002.64 | 53 | 15.03 | 3108 | 2476 | 2.71 / 739.50 | 2 | 3 |
3 | 13 | 1018.68 | 16 | 14.98 | 1786 | 428 | 3.13 / 739.93 | 2 | 4 |
4 | 13 | 456.44 | 16 | 15.07 | 1005 | 242 | 3.38 / 740.17 | 2 | 4 |
5 | 13 | 79.24 | 16 | 15.15 | 439 | 106 | 3.48 / 740.28 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.13 | 304 | 759 | 4.24 / 741.04 | 2 | 5 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.76 | 30 | 15.07 | 491 | 222 | 0.22 / 732.81 | 2 | 3 |
2 | 7 | 2010.00 | 52 | 15.02 | 3119 | 2436 | 2.66 / 735.24 | 2 | 3 |
3 | 13 | 1020.20 | 16 | 14.96 | 1801 | 431 | 3.09 / 735.67 | 2 | 4 |
4 | 13 | 468.76 | 16 | 15.06 | 1027 | 247 | 3.34 / 735.92 | 2 | 4 |
5 | 13 | 82.24 | 16 | 15.15 | 455 | 110 | 3.45 / 736.03 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.12 | 308 | 768 | 4.22 / 736.80 | 2 | 4 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 30 | 15.08 | 472 | 214 | 0.21 / 728.54 | 2 | 3 |
2 | 7 | 2011.88 | 53 | 15.02 | 3122 | 2485 | 2.70 / 731.03 | 2 | 3 |
3 | 13 | 1026.88 | 16 | 14.97 | 1806 | 433 | 3.13 / 731.46 | 2 | 3 |
4 | 13 | 467.80 | 16 | 15.06 | 1024 | 247 | 3.38 / 731.71 | 2 | 4 |
5 | 13 | 80.68 | 16 | 15.14 | 446 | 108 | 3.49 / 731.82 | 2 | 6 |
6 | 8 | -0.08 | 165 | 15.12 | 307 | 766 | 4.25 / 732.58 | 2 | 9 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 30 | 15.09 | 491 | 222 | 0.22 / 724.31 | 2 | 3 |
2 | 7 | 2010.52 | 53 | 15.03 | 3110 | 2477 | 2.70 / 726.78 | 2 | 2 |
3 | 13 | 1025.64 | 16 | 14.97 | 1800 | 431 | 3.13 / 727.21 | 2 | 4 |
4 | 13 | 466.52 | 16 | 15.07 | 1026 | 247 | 3.38 / 727.46 | 2 | 4 |
5 | 13 | 87.68 | 16 | 15.15 | 455 | 110 | 3.49 / 727.57 | 2 | 4 |
6 | 8 | 0.12 | 165 | 15.13 | 304 | 759 | 4.25 / 728.33 | 2 | 11 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.68 | 30 | 15.09 | 493 | 223 | 0.22 / 720.10 | 2 | 3 |
2 | 7 | 2003.60 | 52 | 15.04 | 3116 | 2437 | 2.66 / 722.54 | 2 | 3 |
3 | 13 | 1023.40 | 16 | 14.99 | 1801 | 432 | 3.09 / 722.97 | 2 | 4 |
4 | 13 | 461.40 | 16 | 15.07 | 1013 | 244 | 3.34 / 723.21 | 2 | 3 |
5 | 13 | 82.08 | 16 | 15.15 | 446 | 108 | 3.44 / 723.32 | 2 | 6 |
6 | 8 | 0.24 | 165 | 15.14 | 305 | 762 | 4.21 / 724.08 | 2 | 11 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 30 | 15.08 | 497 | 225 | 0.22 / 715.83 | 2 | 3 |
2 | 7 | 2002.56 | 53 | 15.04 | 3103 | 2473 | 2.70 / 718.30 | 2 | 3 |
3 | 13 | 1016.40 | 16 | 14.98 | 1797 | 431 | 3.13 / 718.73 | 2 | 3 |
4 | 13 | 575.36 | 16 | 15.05 | 1183 | 285 | 3.41 / 719.02 | 2 | 4 |
5 | 13 | 68.24 | 16 | 15.16 | 421 | 102 | 3.52 / 719.12 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.13 | 304 | 759 | 4.27 / 719.88 | 2 | 14 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 30 | 15.08 | 484 | 219 | 0.22 / 711.56 | 2 | 3 |
2 | 7 | 2012.56 | 53 | 15.03 | 3121 | 2486 | 2.71 / 714.05 | 2 | 3 |
3 | 13 | 1025.76 | 16 | 14.98 | 1808 | 433 | 3.14 / 714.48 | 2 | 3 |
4 | 13 | 463.20 | 16 | 15.08 | 1019 | 246 | 3.38 / 714.73 | 2 | 4 |
5 | 13 | 91.28 | 16 | 15.15 | 461 | 112 | 3.50 / 714.84 | 2 | 8 |
6 | 8 | 0.00 | 165 | 15.14 | 305 | 762 | 4.26 / 715.60 | 2 | 10 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 30 | 15.09 | 460 | 208 | 0.21 / 707.30 | 2 | 3 |
2 | 7 | 2011.24 | 53 | 15.03 | 3127 | 2491 | 2.70 / 709.80 | 2 | 3 |
3 | 13 | 1025.04 | 16 | 14.98 | 1812 | 434 | 3.13 / 710.23 | 2 | 4 |
4 | 13 | 457.28 | 16 | 15.07 | 1012 | 244 | 3.38 / 710.47 | 2 | 3 |
5 | 13 | 84.52 | 16 | 15.16 | 450 | 109 | 3.49 / 710.58 | 2 | 7 |
6 | 8 | 0.04 | 165 | 15.13 | 305 | 761 | 4.25 / 711.34 | 2 | 10 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 30 | 15.09 | 484 | 219 | 0.22 / 703.05 | 2 | 3 |
2 | 7 | 2011.44 | 53 | 15.03 | 3131 | 2494 | 2.71 / 705.54 | 2 | 3 |
3 | 13 | 1028.24 | 16 | 14.98 | 1811 | 434 | 3.15 / 705.97 | 2 | 5 |
4 | 13 | 466.72 | 16 | 15.08 | 1027 | 248 | 3.40 / 706.22 | 2 | 4 |
5 | 13 | 82.28 | 16 | 15.16 | 453 | 110 | 3.50 / 706.33 | 2 | 5 |
6 | 8 | 0.12 | 165 | 15.14 | 306 | 764 | 4.27 / 707.10 | 2 | 9 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 30 | 15.06 | 481 | 217 | 0.22 / 698.80 | 2 | 3 |
2 | 7 | 2009.20 | 53 | 15.04 | 3114 | 2482 | 2.70 / 701.28 | 2 | 3 |
3 | 13 | 1015.92 | 16 | 14.98 | 1796 | 430 | 3.13 / 701.71 | 2 | 4 |
4 | 13 | 456.44 | 16 | 15.08 | 1009 | 243 | 3.37 / 701.96 | 2 | 4 |
5 | 13 | 80.16 | 16 | 15.16 | 452 | 110 | 3.48 / 702.07 | 2 | 5 |
6 | 8 | 0.00 | 165 | 15.13 | 305 | 761 | 4.24 / 702.83 | 2 | 12 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 30 | 15.08 | 462 | 209 | 0.21 / 694.25 | 2 | 3 |
2 | 7 | 2003.88 | 52 | 15.02 | 3113 | 2431 | 2.64 / 696.68 | 2 | 3 |
3 | 13 | 1028.92 | 16 | 14.96 | 1806 | 432 | 3.07 / 697.12 | 2 | 3 |
4 | 13 | 466.76 | 16 | 15.07 | 1022 | 246 | 3.32 / 697.36 | 2 | 4 |
5 | 13 | 89.68 | 16 | 15.14 | 458 | 111 | 3.43 / 697.47 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.12 | 307 | 766 | 4.20 / 698.24 | 2 | 4 |
7 | 14 | 0.16 | 75 | 15.09 | 303 | 343 | 4.54 / 698.58 | 2 | 13 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 30 | 15.08 | 459 | 208 | 0.21 / 690.00 | 2 | 3 |
2 | 7 | 2010.96 | 53 | 15.04 | 3127 | 2493 | 2.70 / 692.50 | 2 | 3 |
3 | 13 | 1020.52 | 16 | 14.98 | 1803 | 432 | 3.13 / 692.93 | 2 | 4 |
4 | 13 | 460.08 | 16 | 15.08 | 1017 | 245 | 3.38 / 693.17 | 2 | 4 |
5 | 13 | 85.68 | 16 | 15.16 | 454 | 110 | 3.49 / 693.28 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.13 | 304 | 759 | 4.25 / 694.04 | 2 | 11 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.00 | 30 | 15.09 | 481 | 218 | 0.22 / 685.78 | 2 | 3 |
2 | 7 | 2011.72 | 53 | 15.05 | 3118 | 2487 | 2.70 / 688.27 | 2 | 2 |
3 | 13 | 910.52 | 16 | 15.00 | 1659 | 398 | 3.10 / 688.67 | 2 | 4 |
4 | 13 | 502.04 | 16 | 15.08 | 1070 | 258 | 3.36 / 688.93 | 2 | 3 |
5 | 13 | 101.96 | 16 | 15.15 | 477 | 116 | 3.48 / 689.04 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.14 | 302 | 754 | 4.23 / 689.80 | 2 | 9 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.20 | 30 | 15.08 | 482 | 218 | 0.22 / 681.53 | 2 | 3 |
2 | 7 | 2011.44 | 53 | 15.04 | 3124 | 2490 | 2.71 / 684.02 | 2 | 3 |
3 | 13 | 1025.00 | 16 | 15.00 | 1807 | 434 | 3.14 / 684.45 | 2 | 4 |
4 | 13 | 453.92 | 16 | 15.09 | 1010 | 244 | 3.39 / 684.69 | 2 | 4 |
5 | 13 | 80.12 | 16 | 15.16 | 446 | 108 | 3.49 / 684.80 | 2 | 3 |
6 | 8 | 0.32 | 165 | 15.15 | 305 | 762 | 4.26 / 685.57 | 2 | 11 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 30 | 15.07 | 457 | 207 | 0.21 / 677.24 | 2 | 3 |
2 | 7 | 2004.28 | 53 | 15.04 | 3122 | 2489 | 2.70 / 679.73 | 2 | 3 |
3 | 13 | 1020.48 | 16 | 14.99 | 1794 | 430 | 3.13 / 680.16 | 2 | 4 |
4 | 13 | 578.36 | 16 | 15.05 | 1186 | 286 | 3.41 / 680.45 | 2 | 4 |
5 | 13 | 71.80 | 16 | 15.17 | 427 | 104 | 3.51 / 680.55 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.14 | 303 | 757 | 4.27 / 681.31 | 2 | 8 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.08 | 30 | 15.08 | 492 | 223 | 0.22 / 673.02 | 2 | 3 |
2 | 7 | 2010.20 | 53 | 15.03 | 3116 | 2482 | 2.70 / 675.50 | 2 | 3 |
3 | 13 | 1021.96 | 16 | 14.97 | 1799 | 431 | 3.14 / 675.93 | 2 | 4 |
4 | 13 | 451.00 | 16 | 15.07 | 1000 | 241 | 3.38 / 676.17 | 2 | 4 |
5 | 13 | 81.40 | 16 | 15.15 | 443 | 107 | 3.48 / 676.28 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.13 | 304 | 759 | 4.24 / 677.04 | 2 | 7 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.44 | 30 | 15.09 | 481 | 218 | 0.22 / 668.76 | 2 | 3 |
2 | 7 | 2005.20 | 53 | 15.04 | 3112 | 2481 | 2.70 / 671.24 | 2 | 3 |
3 | 13 | 1021.24 | 16 | 14.99 | 1801 | 432 | 3.13 / 671.67 | 2 | 3 |
4 | 13 | 458.32 | 16 | 15.08 | 1008 | 243 | 3.37 / 671.92 | 2 | 4 |
5 | 13 | 86.44 | 16 | 15.16 | 454 | 110 | 3.48 / 672.03 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.13 | 308 | 769 | 4.25 / 672.79 | 2 | 6 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 30 | 15.09 | 457 | 207 | 0.21 / 664.55 | 2 | 3 |
2 | 7 | 2011.00 | 52 | 15.03 | 3117 | 2436 | 2.64 / 666.98 | 2 | 2 |
3 | 13 | 1028.44 | 16 | 14.97 | 1807 | 433 | 3.08 / 667.42 | 2 | 3 |
4 | 13 | 466.20 | 16 | 15.08 | 1019 | 246 | 3.32 / 667.66 | 2 | 4 |
5 | 13 | 86.52 | 16 | 15.15 | 461 | 112 | 3.43 / 667.78 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.13 | 307 | 766 | 4.20 / 668.54 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 30 | 15.09 | 448 | 203 | 0.20 / 660.31 | 2 | 3 |
2 | 7 | 2013.28 | 53 | 15.03 | 3117 | 2483 | 2.69 / 662.80 | 2 | 3 |
3 | 13 | 1012.60 | 16 | 14.99 | 1785 | 428 | 3.11 / 663.23 | 2 | 4 |
4 | 13 | 454.96 | 16 | 15.08 | 1003 | 242 | 3.36 / 663.47 | 2 | 4 |
5 | 13 | 81.32 | 16 | 15.15 | 445 | 108 | 3.46 / 663.58 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.14 | 307 | 767 | 4.23 / 664.34 | 2 | 6 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 30 | 15.08 | 458 | 207 | 0.21 / 656.08 | 2 | 3 |
2 | 7 | 2012.40 | 53 | 15.03 | 3112 | 2479 | 2.69 / 658.56 | 2 | 2 |
3 | 13 | 1028.04 | 16 | 14.98 | 1801 | 432 | 3.12 / 658.99 | 2 | 4 |
4 | 13 | 465.72 | 16 | 15.08 | 1026 | 248 | 3.37 / 659.24 | 2 | 4 |
5 | 13 | 83.00 | 16 | 15.16 | 452 | 110 | 3.48 / 659.35 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.14 | 304 | 759 | 4.23 / 660.11 | 2 | 4 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.92 | 30 | 15.09 | 483 | 219 | 0.22 / 651.85 | 2 | 3 |
2 | 7 | 2004.32 | 53 | 15.03 | 3110 | 2477 | 2.70 / 654.33 | 2 | 3 |
3 | 13 | 1015.84 | 16 | 14.98 | 1794 | 430 | 3.13 / 654.76 | 2 | 3 |
4 | 13 | 453.00 | 16 | 15.08 | 1000 | 241 | 3.37 / 655.00 | 2 | 4 |
5 | 13 | 82.56 | 16 | 15.16 | 446 | 108 | 3.48 / 655.11 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.13 | 308 | 769 | 4.24 / 655.88 | 2 | 13 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 30 | 15.10 | 481 | 218 | 0.22 / 647.59 | 2 | 3 |
2 | 7 | 2009.48 | 53 | 15.05 | 3115 | 2485 | 2.70 / 650.08 | 2 | 3 |
3 | 13 | 1027.88 | 16 | 14.99 | 1808 | 434 | 3.14 / 650.51 | 2 | 4 |
4 | 13 | 466.00 | 16 | 15.08 | 1020 | 246 | 3.38 / 650.76 | 2 | 4 |
5 | 13 | 84.24 | 16 | 15.17 | 452 | 110 | 3.49 / 650.86 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.15 | 307 | 767 | 4.26 / 651.63 | 2 | 10 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.44 | 30 | 15.09 | 491 | 222 | 0.22 / 643.35 | 2 | 3 |
2 | 7 | 2003.24 | 53 | 15.04 | 3113 | 2481 | 2.70 / 645.83 | 2 | 3 |
3 | 13 | 1011.52 | 16 | 15.00 | 1779 | 427 | 3.13 / 646.26 | 2 | 3 |
4 | 13 | 453.60 | 16 | 15.10 | 1003 | 242 | 3.37 / 646.50 | 2 | 4 |
5 | 13 | 74.60 | 16 | 15.18 | 432 | 105 | 3.48 / 646.61 | 2 | 4 |
6 | 8 | 0.12 | 165 | 15.15 | 307 | 767 | 4.25 / 647.37 | 2 | 5 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 30 | 15.10 | 483 | 219 | 0.22 / 639.04 | 2 | 3 |
2 | 7 | 2002.64 | 53 | 15.04 | 3106 | 2476 | 2.69 / 641.52 | 2 | 3 |
3 | 13 | 1024.64 | 16 | 14.99 | 1801 | 432 | 3.13 / 641.95 | 2 | 4 |
4 | 13 | 580.40 | 16 | 15.06 | 1191 | 287 | 3.41 / 642.24 | 2 | 4 |
5 | 13 | 126.20 | 16 | 15.16 | 516 | 125 | 3.54 / 642.36 | 2 | 5 |
6 | 8 | 0.20 | 165 | 15.15 | 306 | 765 | 4.30 / 643.13 | 2 | 7 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.72 | 30 | 15.09 | 495 | 224 | 0.22 / 634.82 | 2 | 3 |
2 | 7 | 2002.84 | 53 | 15.05 | 3111 | 2481 | 2.71 / 637.30 | 2 | 3 |
3 | 13 | 914.48 | 16 | 15.02 | 1647 | 396 | 3.10 / 637.70 | 2 | 4 |
4 | 13 | 502.52 | 16 | 15.09 | 1067 | 258 | 3.36 / 637.95 | 2 | 3 |
5 | 13 | 97.80 | 16 | 15.17 | 467 | 113 | 3.47 / 638.07 | 2 | 5 |
6 | 8 | -0.04 | 165 | 15.14 | 303 | 757 | 4.23 / 638.82 | 2 | 10 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.84 | 30 | 15.10 | 488 | 221 | 0.22 / 630.56 | 2 | 2 |
2 | 7 | 2012.04 | 52 | 15.05 | 3123 | 2444 | 2.67 / 633.01 | 2 | 3 |
3 | 13 | 1022.84 | 16 | 15.00 | 1798 | 432 | 3.10 / 633.44 | 2 | 3 |
4 | 13 | 588.56 | 16 | 15.06 | 1194 | 288 | 3.38 / 633.73 | 2 | 4 |
5 | 13 | 71.92 | 16 | 15.17 | 428 | 104 | 3.49 / 633.83 | 2 | 5 |
6 | 8 | 0.08 | 165 | 15.15 | 306 | 765 | 4.25 / 634.59 | 2 | 9 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 30 | 15.10 | 490 | 222 | 0.22 / 626.31 | 2 | 3 |
2 | 7 | 2003.36 | 52 | 15.05 | 3108 | 2432 | 2.65 / 628.74 | 2 | 2 |
3 | 13 | 1012.32 | 16 | 15.00 | 1782 | 428 | 3.08 / 629.17 | 2 | 3 |
4 | 13 | 574.12 | 16 | 15.07 | 1174 | 283 | 3.37 / 629.45 | 2 | 3 |
5 | 13 | 125.88 | 16 | 15.17 | 518 | 126 | 3.49 / 629.58 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.15 | 306 | 765 | 4.26 / 630.34 | 2 | 9 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.32 | 30 | 15.09 | 494 | 224 | 0.22 / 622.03 | 2 | 3 |
2 | 7 | 2010.72 | 53 | 15.04 | 3139 | 2502 | 2.73 / 624.53 | 2 | 3 |
3 | 13 | 1026.72 | 16 | 15.01 | 1805 | 433 | 3.16 / 624.96 | 2 | 3 |
4 | 13 | 467.24 | 16 | 15.10 | 1020 | 246 | 3.41 / 625.21 | 2 | 4 |
5 | 13 | 85.12 | 16 | 15.18 | 454 | 110 | 3.52 / 625.32 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.15 | 307 | 767 | 4.28 / 626.09 | 2 | 9 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.36 | 30 | 15.10 | 492 | 223 | 0.22 / 617.82 | 2 | 3 |
2 | 7 | 2009.44 | 52 | 15.04 | 3115 | 2436 | 2.66 / 620.26 | 2 | 3 |
3 | 13 | 1012.24 | 16 | 14.99 | 1782 | 427 | 3.09 / 620.69 | 2 | 3 |
4 | 13 | 448.04 | 16 | 15.08 | 996 | 240 | 3.33 / 620.93 | 2 | 4 |
5 | 13 | 77.80 | 16 | 15.18 | 437 | 106 | 3.43 / 621.04 | 2 | 6 |
6 | 8 | 0.08 | 165 | 15.15 | 307 | 767 | 4.20 / 621.80 | 2 | 8 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.48 | 30 | 15.09 | 493 | 223 | 0.22 / 613.58 | 2 | 3 |
2 | 7 | 2009.72 | 53 | 15.05 | 3113 | 2483 | 2.71 / 616.07 | 2 | 2 |
3 | 13 | 1017.48 | 16 | 15.00 | 1796 | 431 | 3.14 / 616.50 | 2 | 4 |
4 | 13 | 445.24 | 16 | 15.10 | 993 | 240 | 3.38 / 616.74 | 2 | 3 |
5 | 13 | 78.04 | 16 | 15.18 | 440 | 107 | 3.48 / 616.84 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.16 | 303 | 758 | 4.24 / 617.60 | 2 | 5 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.84 | 30 | 15.11 | 491 | 223 | 0.22 / 608.99 | 2 | 3 |
2 | 7 | 2003.72 | 52 | 15.04 | 3102 | 2426 | 2.65 / 611.41 | 2 | 3 |
3 | 13 | 1031.56 | 16 | 15.00 | 1811 | 435 | 3.08 / 611.85 | 2 | 3 |
4 | 13 | 581.20 | 16 | 15.07 | 1189 | 287 | 3.37 / 612.14 | 2 | 4 |
5 | 13 | 123.16 | 16 | 15.16 | 510 | 124 | 3.49 / 612.26 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.15 | 304 | 760 | 4.25 / 613.02 | 2 | 5 |
7 | 14 | 0.28 | 75 | 15.12 | 300 | 340 | 4.59 / 613.36 | 3 | 14 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.24 | 30 | 15.13 | 496 | 225 | 0.23 / 604.68 | 2 | 3 |
2 | 7 | 2008.44 | 53 | 15.06 | 3115 | 2486 | 2.71 / 607.17 | 2 | 3 |
3 | 13 | 1013.08 | 16 | 15.01 | 1789 | 430 | 3.14 / 607.60 | 2 | 4 |
4 | 13 | 570.80 | 16 | 15.08 | 1177 | 284 | 3.43 / 607.88 | 2 | 4 |
5 | 13 | 118.28 | 16 | 15.18 | 504 | 122 | 3.55 / 608.00 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.16 | 305 | 763 | 4.31 / 608.77 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.04 | 30 | 15.10 | 489 | 222 | 0.22 / 600.42 | 2 | 2 |
2 | 7 | 2003.36 | 53 | 15.07 | 3110 | 2484 | 2.71 / 602.91 | 2 | 3 |
3 | 13 | 1019.24 | 16 | 15.02 | 1802 | 433 | 3.14 / 603.34 | 2 | 5 |
4 | 13 | 457.00 | 16 | 15.10 | 1015 | 245 | 3.38 / 603.58 | 2 | 3 |
5 | 13 | 81.20 | 16 | 15.19 | 446 | 108 | 3.49 / 603.69 | 2 | 5 |
6 | 8 | 0.32 | 165 | 15.17 | 305 | 763 | 4.26 / 604.46 | 2 | 11 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 30 | 15.10 | 467 | 212 | 0.21 / 595.82 | 2 | 3 |
2 | 7 | 2007.76 | 53 | 15.05 | 3116 | 2485 | 2.70 / 598.30 | 2 | 3 |
3 | 13 | 1025.40 | 16 | 15.01 | 1804 | 433 | 3.13 / 598.74 | 2 | 3 |
4 | 13 | 458.32 | 16 | 15.10 | 1016 | 245 | 3.38 / 598.98 | 2 | 3 |
5 | 13 | 84.64 | 16 | 15.18 | 449 | 109 | 3.48 / 599.09 | 2 | 7 |
6 | 8 | 0.36 | 165 | 15.16 | 307 | 768 | 4.25 / 599.86 | 2 | 3 |
7 | 14 | 0.36 | 75 | 15.13 | 300 | 340 | 4.59 / 600.20 | 2 | 14 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 30 | 15.09 | 483 | 219 | 0.22 / 591.24 | 2 | 2 |
2 | 7 | 2004.64 | 53 | 15.06 | 3120 | 2490 | 2.71 / 593.73 | 2 | 3 |
3 | 13 | 1002.76 | 16 | 15.02 | 1775 | 427 | 3.14 / 594.16 | 2 | 4 |
4 | 13 | 439.12 | 16 | 15.12 | 985 | 238 | 3.37 / 594.40 | 2 | 4 |
5 | 13 | 81.24 | 16 | 15.19 | 444 | 108 | 3.48 / 594.51 | 2 | 4 |
6 | 8 | 0.12 | 165 | 15.17 | 303 | 758 | 4.24 / 595.27 | 2 | 7 |
7 | 14 | 0.12 | 75 | 15.14 | 301 | 342 | 4.58 / 595.61 | 2 | 13 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.20 | 30 | 15.12 | 494 | 224 | 0.22 / 586.69 | 2 | 3 |
2 | 7 | 2003.32 | 53 | 15.05 | 3107 | 2478 | 2.70 / 589.17 | 2 | 3 |
3 | 13 | 900.04 | 16 | 15.03 | 1635 | 393 | 3.10 / 589.56 | 2 | 4 |
4 | 13 | 476.52 | 16 | 15.10 | 1039 | 251 | 3.35 / 589.81 | 2 | 4 |
5 | 13 | 84.16 | 16 | 15.18 | 450 | 109 | 3.46 / 589.92 | 2 | 5 |
6 | 8 | -0.08 | 165 | 15.16 | 305 | 763 | 4.22 / 590.68 | 2 | 5 |
7 | 14 | -0.08 | 75 | 15.13 | 300 | 340 | 4.56 / 591.03 | 3 | 21 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 30 | 15.10 | 492 | 223 | 0.22 / 582.41 | 2 | 3 |
2 | 7 | 2012.12 | 53 | 15.05 | 3139 | 2504 | 2.73 / 584.92 | 2 | 3 |
3 | 13 | 1023.92 | 16 | 15.01 | 1806 | 434 | 3.16 / 585.35 | 2 | 4 |
4 | 13 | 456.08 | 16 | 15.11 | 1014 | 245 | 3.41 / 585.60 | 2 | 4 |
5 | 13 | 82.52 | 16 | 15.19 | 446 | 108 | 3.51 / 585.71 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.17 | 304 | 761 | 4.27 / 586.47 | 2 | 11 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 30 | 15.11 | 493 | 223 | 0.22 / 578.16 | 2 | 3 |
2 | 7 | 2004.08 | 53 | 15.05 | 3109 | 2480 | 2.70 / 580.64 | 2 | 3 |
3 | 13 | 1025.84 | 16 | 15.00 | 1807 | 434 | 3.14 / 581.07 | 2 | 4 |
4 | 13 | 465.48 | 16 | 15.10 | 1027 | 248 | 3.39 / 581.32 | 2 | 4 |
5 | 13 | 85.80 | 16 | 15.18 | 452 | 110 | 3.49 / 581.43 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.16 | 305 | 763 | 4.26 / 582.19 | 2 | 7 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 29 | 15.11 | 485 | 213 | 0.21 / 573.95 | 2 | 3 |
2 | 7 | 2010.72 | 52 | 15.04 | 3116 | 2437 | 2.65 / 576.39 | 2 | 3 |
3 | 13 | 1012.84 | 16 | 15.01 | 1788 | 429 | 3.08 / 576.82 | 2 | 4 |
4 | 13 | 451.16 | 16 | 15.10 | 1001 | 242 | 3.32 / 577.06 | 2 | 3 |
5 | 13 | 83.88 | 16 | 15.19 | 451 | 110 | 3.43 / 577.17 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.16 | 305 | 763 | 4.19 / 577.93 | 2 | 5 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 29 | 15.11 | 490 | 215 | 0.21 / 569.72 | 2 | 3 |
2 | 7 | 2004.96 | 53 | 15.05 | 3111 | 2481 | 2.70 / 572.20 | 2 | 3 |
3 | 13 | 1013.80 | 16 | 15.02 | 1792 | 431 | 3.13 / 572.63 | 2 | 4 |
4 | 13 | 454.44 | 16 | 15.11 | 1003 | 242 | 3.37 / 572.87 | 2 | 4 |
5 | 13 | 81.72 | 16 | 15.19 | 446 | 108 | 3.48 / 572.98 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.17 | 303 | 758 | 4.24 / 573.74 | 2 | 5 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 29 | 15.11 | 486 | 213 | 0.21 / 565.48 | 2 | 3 |
2 | 7 | 2013.44 | 53 | 15.05 | 3138 | 2503 | 2.72 / 567.98 | 2 | 3 |
3 | 13 | 899.00 | 16 | 15.03 | 1632 | 392 | 3.11 / 568.37 | 2 | 4 |
4 | 13 | 491.08 | 16 | 15.09 | 1054 | 254 | 3.36 / 568.63 | 2 | 4 |
5 | 13 | 96.44 | 16 | 15.18 | 476 | 116 | 3.48 / 568.74 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.16 | 304 | 760 | 4.24 / 569.50 | 2 | 9 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 29 | 15.12 | 466 | 204 | 0.20 / 561.22 | 2 | 3 |
2 | 7 | 2010.36 | 53 | 15.06 | 3123 | 2493 | 2.70 / 563.71 | 2 | 2 |
3 | 13 | 1016.96 | 16 | 15.01 | 1795 | 431 | 3.13 / 564.15 | 2 | 4 |
4 | 13 | 459.72 | 16 | 15.11 | 1012 | 245 | 3.37 / 564.39 | 2 | 4 |
5 | 13 | 83.64 | 16 | 15.18 | 450 | 109 | 3.48 / 564.50 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.16 | 306 | 765 | 4.25 / 565.26 | 2 | 4 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 29 | 15.12 | 459 | 201 | 0.20 / 557.00 | 2 | 3 |
2 | 7 | 2003.92 | 53 | 15.06 | 3115 | 2486 | 2.69 / 559.48 | 2 | 3 |
3 | 13 | 911.08 | 16 | 15.04 | 1654 | 398 | 3.09 / 559.88 | 2 | 3 |
4 | 13 | 488.52 | 16 | 15.11 | 1055 | 255 | 3.34 / 560.13 | 2 | 4 |
5 | 13 | 95.36 | 16 | 15.19 | 469 | 114 | 3.45 / 560.25 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.17 | 307 | 768 | 4.22 / 561.02 | 2 | 4 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 29 | 15.11 | 482 | 211 | 0.21 / 552.77 | 2 | 3 |
2 | 7 | 2011.36 | 53 | 15.05 | 3114 | 2484 | 2.70 / 555.26 | 2 | 3 |
3 | 13 | 1006.60 | 16 | 15.03 | 1780 | 428 | 3.12 / 555.68 | 2 | 4 |
4 | 13 | 452.96 | 16 | 15.11 | 1000 | 242 | 3.36 / 555.92 | 2 | 3 |
5 | 13 | 81.68 | 16 | 15.19 | 448 | 109 | 3.47 / 556.03 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.16 | 304 | 760 | 4.23 / 556.79 | 2 | 16 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 29 | 15.11 | 479 | 210 | 0.21 / 548.17 | 2 | 3 |
2 | 7 | 2006.60 | 53 | 15.06 | 3118 | 2489 | 2.70 / 550.66 | 2 | 3 |
3 | 13 | 1020.60 | 16 | 15.03 | 1806 | 434 | 3.13 / 551.09 | 2 | 3 |
4 | 13 | 454.24 | 16 | 15.12 | 1006 | 243 | 3.38 / 551.33 | 2 | 3 |
5 | 13 | 84.96 | 16 | 15.20 | 453 | 110 | 3.49 / 551.44 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.17 | 308 | 771 | 4.26 / 552.22 | 2 | 14 |
7 | 14 | 0.16 | 75 | 15.14 | 303 | 344 | 4.60 / 552.56 | 2 | 14 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 29 | 15.12 | 461 | 202 | 0.20 / 543.61 | 2 | 3 |
2 | 7 | 2002.84 | 53 | 15.07 | 3109 | 2483 | 2.69 / 546.10 | 2 | 3 |
3 | 13 | 896.04 | 16 | 15.04 | 1627 | 392 | 3.08 / 546.49 | 2 | 4 |
4 | 13 | 478.24 | 16 | 15.11 | 1042 | 252 | 3.33 / 546.74 | 2 | 3 |
5 | 13 | 85.52 | 16 | 15.20 | 454 | 110 | 3.44 / 546.85 | 2 | 6 |
6 | 8 | -0.12 | 165 | 15.17 | 305 | 763 | 4.20 / 547.61 | 2 | 7 |
7 | 14 | -0.12 | 75 | 15.13 | 303 | 344 | 4.55 / 547.96 | 3 | 8 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.40 | 29 | 15.12 | 487 | 214 | 0.21 / 539.37 | 2 | 3 |
2 | 7 | 2012.16 | 53 | 15.06 | 3125 | 2494 | 2.71 / 541.86 | 2 | 3 |
3 | 13 | 1014.72 | 16 | 15.03 | 1797 | 432 | 3.14 / 542.30 | 2 | 4 |
4 | 13 | 448.60 | 16 | 15.12 | 1000 | 242 | 3.38 / 542.54 | 2 | 4 |
5 | 13 | 78.88 | 16 | 15.20 | 444 | 108 | 3.49 / 542.65 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.17 | 306 | 766 | 4.26 / 543.41 | 2 | 13 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 29 | 15.13 | 459 | 201 | 0.20 / 535.11 | 2 | 3 |
2 | 7 | 2011.36 | 53 | 15.07 | 3129 | 2499 | 2.70 / 537.61 | 2 | 2 |
3 | 13 | 1007.88 | 16 | 15.03 | 1781 | 428 | 3.13 / 538.04 | 2 | 4 |
4 | 13 | 437.20 | 16 | 15.12 | 981 | 237 | 3.37 / 538.28 | 2 | 4 |
5 | 13 | 73.32 | 16 | 15.21 | 436 | 106 | 3.47 / 538.38 | 2 | 5 |
6 | 8 | 0.16 | 165 | 15.18 | 309 | 774 | 4.25 / 539.16 | 2 | 5 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.52 | 29 | 15.13 | 484 | 212 | 0.21 / 530.88 | 2 | 3 |
2 | 7 | 2011.80 | 53 | 15.05 | 3111 | 2481 | 2.69 / 533.37 | 2 | 2 |
3 | 13 | 1012.92 | 16 | 15.01 | 1783 | 428 | 3.12 / 533.79 | 2 | 4 |
4 | 13 | 455.56 | 16 | 15.12 | 1008 | 244 | 3.37 / 534.04 | 2 | 3 |
5 | 13 | 75.36 | 16 | 15.20 | 437 | 106 | 3.47 / 534.14 | 2 | 4 |
6 | 8 | 0.12 | 165 | 15.17 | 306 | 766 | 4.24 / 534.91 | 2 | 8 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 29 | 15.13 | 457 | 201 | 0.20 / 526.64 | 2 | 3 |
2 | 7 | 2010.68 | 53 | 15.06 | 3115 | 2486 | 2.69 / 529.13 | 2 | 3 |
3 | 13 | 1022.36 | 16 | 15.02 | 1796 | 432 | 3.12 / 529.56 | 2 | 4 |
4 | 13 | 449.92 | 16 | 15.12 | 998 | 241 | 3.36 / 529.80 | 2 | 4 |
5 | 13 | 68.60 | 16 | 15.20 | 423 | 103 | 3.46 / 529.91 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.17 | 306 | 766 | 4.23 / 530.67 | 2 | 8 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.64 | 29 | 15.13 | 487 | 214 | 0.21 / 522.46 | 2 | 3 |
2 | 7 | 2012.00 | 52 | 15.06 | 3126 | 2448 | 2.66 / 524.90 | 2 | 3 |
3 | 13 | 1011.60 | 16 | 15.03 | 1787 | 430 | 3.09 / 525.33 | 2 | 3 |
4 | 13 | 459.80 | 16 | 15.13 | 1012 | 245 | 3.34 / 525.58 | 2 | 4 |
5 | 13 | 75.20 | 16 | 15.21 | 435 | 106 | 3.44 / 525.68 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.17 | 303 | 758 | 4.20 / 526.44 | 2 | 3 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 29 | 15.12 | 481 | 211 | 0.21 / 518.28 | 2 | 3 |
2 | 7 | 2008.68 | 52 | 15.06 | 3117 | 2441 | 2.65 / 520.72 | 2 | 3 |
3 | 13 | 1008.32 | 16 | 15.03 | 1778 | 428 | 3.08 / 521.15 | 2 | 3 |
4 | 13 | 435.44 | 16 | 15.12 | 980 | 237 | 3.32 / 521.39 | 2 | 4 |
5 | 13 | 32.76 | 16 | 15.21 | 366 | 89 | 3.41 / 521.48 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.18 | 305 | 764 | 4.17 / 522.24 | 2 | 4 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.88 | 29 | 15.13 | 485 | 213 | 0.21 / 514.05 | 2 | 3 |
2 | 7 | 2007.88 | 53 | 15.07 | 3117 | 2490 | 2.70 / 516.54 | 2 | 3 |
3 | 13 | 1012.80 | 16 | 15.03 | 1787 | 430 | 3.13 / 516.97 | 2 | 4 |
4 | 13 | 451.68 | 16 | 15.12 | 997 | 241 | 3.37 / 517.21 | 2 | 4 |
5 | 13 | 38.76 | 16 | 15.22 | 376 | 92 | 3.46 / 517.30 | 2 | 4 |
6 | 8 | -0.12 | 165 | 15.18 | 307 | 769 | 4.23 / 518.07 | 2 | 6 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 29 | 15.12 | 481 | 211 | 0.21 / 509.85 | 2 | 3 |
2 | 7 | 2008.44 | 53 | 15.08 | 3113 | 2488 | 2.70 / 512.34 | 2 | 3 |
3 | 13 | 905.08 | 16 | 15.04 | 1637 | 394 | 3.09 / 512.73 | 2 | 3 |
4 | 13 | 482.24 | 16 | 15.12 | 1044 | 253 | 3.35 / 512.98 | 2 | 4 |
5 | 13 | 42.08 | 16 | 15.22 | 380 | 93 | 3.44 / 513.07 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.19 | 305 | 764 | 4.20 / 513.84 | 2 | 5 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.64 | 29 | 15.14 | 487 | 214 | 0.21 / 505.25 | 2 | 3 |
2 | 7 | 2006.92 | 53 | 15.07 | 3119 | 2491 | 2.70 / 507.74 | 2 | 3 |
3 | 13 | 1011.20 | 16 | 15.03 | 1784 | 429 | 3.13 / 508.17 | 2 | 3 |
4 | 13 | 432.44 | 16 | 15.14 | 974 | 236 | 3.37 / 508.41 | 2 | 4 |
5 | 13 | 61.16 | 16 | 15.22 | 421 | 103 | 3.47 / 508.51 | 2 | 3 |
6 | 8 | 0.36 | 165 | 15.19 | 311 | 779 | 4.25 / 509.29 | 2 | 5 |
7 | 14 | 0.36 | 75 | 15.15 | 307 | 349 | 4.60 / 509.64 | 3 | 8 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 29 | 15.12 | 481 | 211 | 0.21 / 501.05 | 2 | 3 |
2 | 7 | 2011.72 | 52 | 15.08 | 3120 | 2447 | 2.66 / 503.50 | 2 | 3 |
3 | 13 | 1013.52 | 16 | 15.04 | 1790 | 431 | 3.09 / 503.93 | 2 | 4 |
4 | 13 | 436.60 | 16 | 15.14 | 982 | 238 | 3.33 / 504.17 | 2 | 3 |
5 | 13 | 66.44 | 16 | 15.21 | 426 | 104 | 3.43 / 504.27 | 2 | 4 |
6 | 8 | 0.28 | 165 | 15.19 | 306 | 767 | 4.20 / 505.04 | 2 | 17 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.16 | 29 | 15.15 | 485 | 213 | 0.21 / 496.51 | 2 | 3 |
2 | 7 | 2010.76 | 53 | 15.07 | 3121 | 2493 | 2.71 / 499.00 | 2 | 2 |
3 | 13 | 897.52 | 16 | 15.06 | 1631 | 393 | 3.10 / 499.39 | 2 | 3 |
4 | 13 | 470.20 | 16 | 15.13 | 1029 | 249 | 3.35 / 499.64 | 2 | 4 |
5 | 13 | 40.92 | 16 | 15.23 | 378 | 92 | 3.44 / 499.73 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.19 | 305 | 764 | 4.20 / 500.50 | 2 | 5 |
7 | 14 | 0.04 | 75 | 15.15 | 299 | 340 | 4.54 / 500.84 | 3 | 5 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 29 | 15.13 | 480 | 211 | 0.21 / 492.27 | 2 | 3 |
2 | 7 | 2007.60 | 53 | 15.08 | 3118 | 2492 | 2.70 / 494.76 | 2 | 3 |
3 | 13 | 1019.68 | 16 | 15.04 | 1801 | 433 | 3.14 / 495.19 | 2 | 5 |
4 | 13 | 443.84 | 16 | 15.15 | 991 | 240 | 3.38 / 495.43 | 2 | 3 |
5 | 13 | 66.60 | 16 | 15.22 | 426 | 104 | 3.48 / 495.53 | 2 | 7 |
6 | 8 | -0.08 | 165 | 15.20 | 303 | 760 | 4.24 / 496.29 | 2 | 10 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 29 | 15.16 | 477 | 210 | 0.21 / 487.67 | 2 | 3 |
2 | 7 | 2005.48 | 53 | 15.08 | 3117 | 2491 | 2.70 / 490.16 | 2 | 3 |
3 | 13 | 1013.48 | 16 | 15.05 | 1795 | 432 | 3.13 / 490.59 | 2 | 3 |
4 | 13 | 438.44 | 16 | 15.15 | 984 | 239 | 3.37 / 490.83 | 2 | 4 |
5 | 13 | 62.40 | 16 | 15.23 | 415 | 101 | 3.47 / 490.93 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.21 | 308 | 773 | 4.25 / 491.71 | 2 | 10 |
7 | 14 | 0.16 | 75 | 15.17 | 306 | 348 | 4.59 / 492.05 | 3 | 6 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.96 | 29 | 15.13 | 477 | 209 | 0.21 / 483.42 | 2 | 3 |
2 | 7 | 2011.56 | 53 | 15.09 | 3134 | 2506 | 2.72 / 485.93 | 2 | 2 |
3 | 13 | 1010.80 | 16 | 15.05 | 1787 | 430 | 3.15 / 486.36 | 2 | 4 |
4 | 13 | 432.92 | 16 | 15.15 | 973 | 236 | 3.38 / 486.59 | 2 | 4 |
5 | 13 | 60.88 | 16 | 15.23 | 410 | 100 | 3.48 / 486.69 | 2 | 4 |
6 | 8 | 0.12 | 165 | 15.20 | 306 | 767 | 4.25 / 487.46 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.16 | 29 | 15.15 | 493 | 217 | 0.22 / 478.83 | 2 | 3 |
2 | 7 | 2011.16 | 53 | 15.07 | 3132 | 2502 | 2.72 / 481.34 | 2 | 3 |
3 | 13 | 1005.36 | 16 | 15.04 | 1777 | 428 | 3.15 / 481.76 | 2 | 4 |
4 | 13 | 441.92 | 16 | 15.14 | 985 | 239 | 3.38 / 482.00 | 2 | 4 |
5 | 13 | 63.76 | 16 | 15.22 | 416 | 101 | 3.49 / 482.10 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.19 | 306 | 767 | 4.25 / 482.87 | 2 | 8 |
7 | 14 | 0.08 | 75 | 15.15 | 300 | 341 | 4.59 / 483.21 | 4 | 12 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.68 | 29 | 15.14 | 490 | 215 | 0.22 / 474.62 | 2 | 3 |
2 | 7 | 2009.32 | 53 | 15.08 | 3122 | 2495 | 2.71 / 477.11 | 2 | 2 |
3 | 13 | 896.08 | 16 | 15.08 | 1624 | 392 | 3.10 / 477.51 | 2 | 3 |
4 | 13 | 473.52 | 16 | 15.15 | 1030 | 250 | 3.35 / 477.76 | 2 | 4 |
5 | 13 | 40.52 | 16 | 15.23 | 378 | 92 | 3.44 / 477.85 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.20 | 307 | 770 | 4.21 / 478.62 | 2 | 5 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 29 | 15.15 | 485 | 213 | 0.21 / 470.41 | 2 | 3 |
2 | 7 | 2006.80 | 52 | 15.07 | 3138 | 2459 | 2.67 / 472.87 | 2 | 3 |
3 | 13 | 1002.36 | 16 | 15.04 | 1777 | 428 | 3.10 / 473.30 | 2 | 3 |
4 | 13 | 431.24 | 16 | 15.14 | 976 | 236 | 3.34 / 473.54 | 2 | 3 |
5 | 13 | 62.32 | 16 | 15.22 | 419 | 102 | 3.44 / 473.64 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.19 | 306 | 767 | 4.21 / 474.40 | 2 | 4 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.76 | 29 | 15.15 | 497 | 218 | 0.22 / 466.16 | 2 | 3 |
2 | 7 | 2004.88 | 53 | 15.09 | 3137 | 2509 | 2.73 / 468.67 | 2 | 3 |
3 | 13 | 1001.28 | 16 | 15.05 | 1773 | 427 | 3.15 / 469.09 | 2 | 4 |
4 | 13 | 433.08 | 16 | 15.15 | 977 | 237 | 3.39 / 469.33 | 2 | 4 |
5 | 13 | 62.96 | 16 | 15.23 | 416 | 101 | 3.49 / 469.43 | 2 | 4 |
6 | 8 | 0.20 | 165 | 15.20 | 306 | 767 | 4.26 / 470.20 | 2 | 10 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.88 | 29 | 15.15 | 489 | 215 | 0.21 / 461.96 | 2 | 3 |
2 | 7 | 2004.00 | 52 | 15.07 | 3118 | 2443 | 2.66 / 464.40 | 2 | 3 |
3 | 13 | 1001.20 | 16 | 15.05 | 1774 | 427 | 3.09 / 464.83 | 2 | 4 |
4 | 13 | 431.68 | 16 | 15.16 | 980 | 238 | 3.32 / 465.06 | 2 | 3 |
5 | 13 | 63.12 | 16 | 15.22 | 419 | 102 | 3.43 / 465.17 | 2 | 6 |
6 | 8 | 0.12 | 165 | 15.20 | 308 | 772 | 4.20 / 465.94 | 2 | 14 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.48 | 29 | 15.14 | 491 | 216 | 0.22 / 457.70 | 2 | 3 |
2 | 7 | 2007.80 | 53 | 15.08 | 3122 | 2495 | 2.71 / 460.19 | 2 | 3 |
3 | 13 | 1017.60 | 16 | 15.04 | 1797 | 432 | 3.14 / 460.62 | 2 | 4 |
4 | 13 | 454.20 | 16 | 15.13 | 1003 | 243 | 3.39 / 460.87 | 2 | 4 |
5 | 13 | 72.76 | 16 | 15.21 | 432 | 105 | 3.49 / 460.97 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.19 | 307 | 769 | 4.26 / 461.74 | 2 | 4 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 29 | 15.14 | 478 | 210 | 0.21 / 453.37 | 2 | 3 |
2 | 7 | 2004.96 | 54 | 15.07 | 3119 | 2538 | 2.75 / 455.91 | 2 | 2 |
3 | 13 | 1004.68 | 16 | 15.04 | 1780 | 428 | 3.18 / 456.34 | 2 | 4 |
4 | 13 | 555.92 | 16 | 15.11 | 1152 | 279 | 3.45 / 456.62 | 2 | 3 |
5 | 13 | 56.48 | 16 | 15.22 | 405 | 99 | 3.55 / 456.71 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.19 | 306 | 767 | 4.32 / 457.48 | 2 | 11 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 29 | 15.14 | 489 | 215 | 0.21 / 449.17 | 2 | 3 |
2 | 7 | 2008.44 | 52 | 15.08 | 3120 | 2447 | 2.66 / 451.62 | 2 | 3 |
3 | 13 | 1021.44 | 16 | 15.04 | 1798 | 433 | 3.09 / 452.05 | 2 | 3 |
4 | 13 | 446.32 | 16 | 15.14 | 991 | 240 | 3.33 / 452.29 | 2 | 4 |
5 | 13 | 68.72 | 16 | 15.22 | 421 | 103 | 3.44 / 452.39 | 2 | 6 |
6 | 8 | 0.20 | 165 | 15.20 | 306 | 767 | 4.20 / 453.16 | 2 | 10 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 29 | 15.14 | 489 | 215 | 0.21 / 444.99 | 2 | 3 |
2 | 7 | 2008.28 | 52 | 15.08 | 3123 | 2449 | 2.66 / 447.44 | 2 | 3 |
3 | 13 | 902.36 | 16 | 15.06 | 1638 | 395 | 3.06 / 447.83 | 2 | 3 |
4 | 13 | 480.24 | 16 | 15.13 | 1042 | 252 | 3.31 / 448.09 | 2 | 4 |
5 | 13 | 77.32 | 16 | 15.21 | 437 | 106 | 3.42 / 448.19 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.19 | 305 | 764 | 4.18 / 448.96 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.32 | 29 | 15.14 | 499 | 219 | 0.22 / 440.71 | 2 | 3 |
2 | 7 | 2011.76 | 53 | 15.06 | 3114 | 2486 | 2.70 / 443.19 | 2 | 2 |
3 | 13 | 1002.72 | 16 | 15.04 | 1778 | 428 | 3.13 / 443.62 | 2 | 4 |
4 | 13 | 560.24 | 16 | 15.10 | 1158 | 280 | 3.41 / 443.90 | 2 | 4 |
5 | 13 | 57.76 | 16 | 15.21 | 408 | 99 | 3.51 / 444.00 | 2 | 4 |
6 | 8 | 0.24 | 165 | 15.19 | 309 | 774 | 4.29 / 444.78 | 2 | 5 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 29 | 15.17 | 493 | 217 | 0.22 / 436.45 | 2 | 3 |
2 | 7 | 2010.72 | 53 | 15.08 | 3122 | 2495 | 2.71 / 438.94 | 2 | 3 |
3 | 13 | 1019.04 | 16 | 15.04 | 1794 | 432 | 3.14 / 439.37 | 2 | 3 |
4 | 13 | 446.64 | 16 | 15.14 | 991 | 240 | 3.38 / 439.61 | 2 | 4 |
5 | 13 | 67.28 | 16 | 15.22 | 427 | 104 | 3.49 / 439.72 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.19 | 308 | 772 | 4.26 / 440.49 | 2 | 11 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.08 | 29 | 15.15 | 496 | 218 | 0.22 / 432.22 | 2 | 3 |
2 | 7 | 2009.52 | 53 | 15.10 | 3128 | 2503 | 2.72 / 434.72 | 2 | 3 |
3 | 13 | 902.00 | 16 | 15.07 | 1633 | 394 | 3.12 / 435.11 | 2 | 3 |
4 | 13 | 479.96 | 16 | 15.14 | 1044 | 253 | 3.37 / 435.37 | 2 | 3 |
5 | 13 | 40.84 | 16 | 15.23 | 380 | 93 | 3.46 / 435.46 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.21 | 307 | 770 | 4.23 / 436.23 | 2 | 9 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.40 | 29 | 15.15 | 498 | 219 | 0.22 / 427.96 | 2 | 3 |
2 | 7 | 2012.36 | 53 | 15.08 | 3131 | 2502 | 2.72 / 430.46 | 2 | 2 |
3 | 13 | 1018.36 | 16 | 15.04 | 1796 | 432 | 3.15 / 430.89 | 2 | 3 |
4 | 13 | 443.48 | 16 | 15.13 | 993 | 240 | 3.39 / 431.13 | 2 | 4 |
5 | 13 | 61.36 | 16 | 15.22 | 407 | 99 | 3.49 / 431.23 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.19 | 306 | 767 | 4.26 / 432.00 | 2 | 6 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.00 | 29 | 15.15 | 494 | 217 | 0.22 / 423.69 | 2 | 3 |
2 | 7 | 2008.48 | 53 | 15.08 | 3128 | 2500 | 2.72 / 426.19 | 2 | 3 |
3 | 13 | 1004.96 | 16 | 15.05 | 1777 | 428 | 3.14 / 426.62 | 2 | 3 |
4 | 13 | 442.88 | 16 | 15.15 | 989 | 240 | 3.38 / 426.86 | 2 | 4 |
5 | 13 | 63.12 | 16 | 15.23 | 415 | 101 | 3.49 / 426.96 | 2 | 5 |
6 | 8 | 0.08 | 165 | 15.21 | 309 | 775 | 4.26 / 427.74 | 2 | 6 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.44 | 29 | 15.15 | 492 | 216 | 0.22 / 419.50 | 2 | 2 |
2 | 7 | 2011.96 | 53 | 15.08 | 3135 | 2506 | 2.72 / 422.00 | 2 | 3 |
3 | 13 | 896.88 | 16 | 15.07 | 1632 | 394 | 3.12 / 422.40 | 2 | 3 |
4 | 13 | 361.08 | 16 | 15.17 | 872 | 212 | 3.33 / 422.61 | 2 | 4 |
5 | 13 | 50.40 | 16 | 15.23 | 399 | 97 | 3.42 / 422.70 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.20 | 308 | 772 | 4.20 / 423.48 | 2 | 11 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 29 | 15.14 | 497 | 218 | 0.22 / 415.22 | 2 | 3 |
2 | 7 | 2006.92 | 53 | 15.08 | 3147 | 2515 | 2.73 / 417.73 | 2 | 2 |
3 | 13 | 1006.52 | 16 | 15.05 | 1788 | 431 | 3.16 / 418.16 | 2 | 4 |
4 | 13 | 436.84 | 16 | 15.15 | 982 | 238 | 3.40 / 418.40 | 2 | 4 |
5 | 13 | 62.32 | 16 | 15.23 | 416 | 101 | 3.50 / 418.50 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.21 | 311 | 781 | 4.28 / 419.28 | 2 | 10 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.28 | 29 | 15.16 | 487 | 214 | 0.21 / 410.99 | 2 | 3 |
2 | 7 | 2008.64 | 53 | 15.09 | 3128 | 2502 | 2.72 / 413.49 | 2 | 3 |
3 | 13 | 898.56 | 16 | 15.07 | 1637 | 395 | 3.11 / 413.89 | 2 | 4 |
4 | 13 | 473.40 | 16 | 15.14 | 1039 | 252 | 3.36 / 414.14 | 2 | 4 |
5 | 13 | 40.80 | 16 | 15.24 | 379 | 92 | 3.45 / 414.23 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.20 | 305 | 765 | 4.22 / 415.00 | 2 | 12 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 29 | 15.16 | 494 | 217 | 0.22 / 406.78 | 2 | 3 |
2 | 7 | 2008.00 | 53 | 15.09 | 3132 | 2505 | 2.72 / 409.28 | 2 | 3 |
3 | 13 | 884.60 | 16 | 15.08 | 1617 | 390 | 3.11 / 409.67 | 2 | 4 |
4 | 13 | 460.56 | 16 | 15.15 | 1018 | 247 | 3.36 / 409.92 | 2 | 4 |
5 | 13 | 38.52 | 16 | 15.24 | 374 | 91 | 3.45 / 410.01 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.20 | 305 | 765 | 4.22 / 410.78 | 2 | 8 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 29 | 15.17 | 463 | 204 | 0.20 / 402.52 | 2 | 3 |
2 | 7 | 2008.92 | 53 | 15.08 | 3133 | 2504 | 2.71 / 405.02 | 2 | 3 |
3 | 13 | 1010.08 | 16 | 15.06 | 1789 | 431 | 3.14 / 405.45 | 2 | 4 |
4 | 13 | 431.88 | 16 | 15.16 | 976 | 237 | 3.38 / 405.69 | 2 | 3 |
5 | 13 | 62.56 | 16 | 15.24 | 419 | 102 | 3.48 / 405.79 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.21 | 308 | 773 | 4.25 / 406.56 | 2 | 11 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.92 | 29 | 15.16 | 500 | 220 | 0.22 / 398.30 | 2 | 3 |
2 | 7 | 2005.68 | 53 | 15.09 | 3131 | 2504 | 2.72 / 400.80 | 2 | 3 |
3 | 13 | 888.32 | 16 | 15.09 | 1619 | 391 | 3.11 / 401.19 | 2 | 4 |
4 | 13 | 467.68 | 16 | 15.16 | 1028 | 249 | 3.36 / 401.44 | 2 | 4 |
5 | 13 | 76.92 | 16 | 15.24 | 438 | 107 | 3.47 / 401.55 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.22 | 304 | 763 | 4.23 / 402.31 | 2 | 8 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 29 | 15.16 | 473 | 208 | 0.21 / 394.03 | 2 | 3 |
2 | 7 | 2007.44 | 53 | 15.09 | 3132 | 2505 | 2.71 / 396.54 | 2 | 3 |
3 | 13 | 1010.68 | 16 | 15.07 | 1798 | 434 | 3.15 / 396.97 | 2 | 4 |
4 | 13 | 433.76 | 16 | 15.16 | 989 | 240 | 3.39 / 397.21 | 2 | 4 |
5 | 13 | 70.52 | 16 | 15.24 | 431 | 105 | 3.49 / 397.31 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.21 | 304 | 763 | 4.25 / 398.08 | 2 | 10 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.76 | 29 | 15.16 | 491 | 216 | 0.22 / 389.78 | 2 | 3 |
2 | 7 | 2007.40 | 53 | 15.10 | 3134 | 2508 | 2.72 / 392.29 | 2 | 3 |
3 | 13 | 1004.20 | 16 | 15.06 | 1781 | 429 | 3.15 / 392.72 | 2 | 3 |
4 | 13 | 432.08 | 16 | 15.16 | 976 | 237 | 3.39 / 392.96 | 2 | 3 |
5 | 13 | 73.68 | 16 | 15.23 | 436 | 106 | 3.50 / 393.06 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.21 | 303 | 760 | 4.26 / 393.82 | 2 | 5 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.04 | 29 | 15.14 | 485 | 213 | 0.21 / 385.51 | 2 | 3 |
2 | 7 | 2007.76 | 54 | 15.10 | 3126 | 2549 | 2.76 / 388.06 | 2 | 3 |
3 | 13 | 882.24 | 16 | 15.08 | 1611 | 389 | 3.15 / 388.45 | 2 | 3 |
4 | 13 | 456.00 | 16 | 15.15 | 1008 | 244 | 3.39 / 388.69 | 2 | 4 |
5 | 13 | 76.16 | 16 | 15.24 | 435 | 106 | 3.50 / 388.80 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.21 | 306 | 768 | 4.27 / 389.57 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 29 | 15.16 | 463 | 204 | 0.20 / 381.28 | 2 | 3 |
2 | 7 | 2004.16 | 53 | 15.09 | 3114 | 2490 | 2.69 / 383.77 | 2 | 3 |
3 | 13 | 1008.00 | 16 | 15.05 | 1781 | 429 | 3.12 / 384.20 | 2 | 3 |
4 | 13 | 434.64 | 16 | 15.15 | 979 | 237 | 3.36 / 384.44 | 2 | 4 |
5 | 13 | 75.00 | 16 | 15.23 | 432 | 105 | 3.47 / 384.54 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.20 | 301 | 755 | 4.22 / 385.30 | 2 | 13 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.28 | 29 | 15.16 | 483 | 212 | 0.21 / 377.05 | 2 | 3 |
2 | 7 | 2012.24 | 53 | 15.09 | 3138 | 2510 | 2.72 / 379.56 | 2 | 3 |
3 | 13 | 896.32 | 16 | 15.08 | 1631 | 394 | 3.12 / 379.95 | 2 | 4 |
4 | 13 | 464.68 | 16 | 15.15 | 1018 | 247 | 3.36 / 380.20 | 2 | 3 |
5 | 13 | 77.80 | 16 | 15.23 | 441 | 107 | 3.47 / 380.31 | 2 | 2 |
6 | 8 | 0.24 | 165 | 15.20 | 307 | 770 | 4.24 / 381.08 | 2 | 3 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.04 | 29 | 15.16 | 487 | 214 | 0.21 / 372.81 | 2 | 3 |
2 | 7 | 2003.48 | 53 | 15.10 | 3128 | 2503 | 2.72 / 375.31 | 2 | 3 |
3 | 13 | 1001.12 | 16 | 15.07 | 1776 | 428 | 3.15 / 375.74 | 2 | 3 |
4 | 13 | 421.56 | 16 | 15.17 | 959 | 233 | 3.38 / 375.97 | 2 | 3 |
5 | 13 | 66.20 | 16 | 15.24 | 424 | 103 | 3.48 / 376.07 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.21 | 304 | 763 | 4.24 / 376.84 | 2 | 10 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 29 | 15.15 | 464 | 204 | 0.20 / 368.57 | 2 | 3 |
2 | 7 | 2004.52 | 53 | 15.10 | 3124 | 2500 | 2.70 / 371.07 | 2 | 3 |
3 | 13 | 996.56 | 16 | 15.05 | 1765 | 425 | 3.13 / 371.49 | 2 | 3 |
4 | 13 | 425.84 | 16 | 15.16 | 971 | 236 | 3.36 / 371.73 | 2 | 4 |
5 | 13 | 66.68 | 16 | 15.24 | 421 | 103 | 3.47 / 371.83 | 2 | 6 |
6 | 8 | 0.00 | 165 | 15.21 | 303 | 760 | 4.23 / 372.59 | 2 | 8 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.08 | 29 | 15.15 | 486 | 214 | 0.21 / 363.90 | 2 | 3 |
2 | 7 | 2004.28 | 53 | 15.10 | 3133 | 2507 | 2.72 / 366.41 | 2 | 3 |
3 | 13 | 895.20 | 16 | 15.09 | 1634 | 395 | 3.12 / 366.80 | 2 | 4 |
4 | 13 | 475.68 | 16 | 15.16 | 1039 | 252 | 3.37 / 367.06 | 2 | 4 |
5 | 13 | 105.64 | 16 | 15.23 | 483 | 118 | 3.49 / 367.17 | 2 | 3 |
6 | 13 | 32.16 | 16 | 15.24 | 362 | 88 | 3.57 / 367.26 | 2 | 3 |
7 | 8 | 0.40 | 165 | 15.21 | 304 | 763 | 4.34 / 368.02 | 2 | 14 |
8 | 14 | 0.40 | 75 | 15.18 | 299 | 340 | 4.68 / 368.36 | 3 | 23 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 29 | 15.15 | 474 | 208 | 0.21 / 359.62 | 2 | 3 |
2 | 7 | 2007.04 | 53 | 15.10 | 3124 | 2500 | 2.71 / 362.12 | 2 | 3 |
3 | 13 | 1005.92 | 16 | 15.06 | 1785 | 430 | 3.14 / 362.55 | 2 | 3 |
4 | 13 | 559.44 | 16 | 15.13 | 1160 | 281 | 3.42 / 362.83 | 2 | 4 |
5 | 13 | 61.76 | 16 | 15.24 | 410 | 100 | 3.52 / 362.93 | 2 | 4 |
6 | 8 | -0.04 | 165 | 15.21 | 302 | 758 | 4.28 / 363.69 | 2 | 5 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 29 | 15.17 | 455 | 200 | 0.20 / 354.96 | 2 | 3 |
2 | 7 | 2003.00 | 53 | 15.10 | 3122 | 2499 | 2.70 / 357.46 | 2 | 3 |
3 | 13 | 998.84 | 16 | 15.07 | 1778 | 429 | 3.13 / 357.89 | 2 | 3 |
4 | 13 | 434.08 | 16 | 15.16 | 977 | 237 | 3.36 / 358.12 | 2 | 3 |
5 | 13 | 59.32 | 16 | 15.24 | 407 | 99 | 3.46 / 358.22 | 2 | 3 |
6 | 13 | 14.40 | 16 | 15.24 | 336 | 82 | 3.55 / 358.30 | 2 | 4 |
7 | 8 | -0.04 | 165 | 15.20 | 304 | 762 | 4.31 / 359.07 | 2 | 9 |
8 | 14 | -0.04 | 75 | 15.16 | 303 | 345 | 4.65 / 359.41 | 3 | 14 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 29 | 15.17 | 470 | 207 | 0.21 / 350.77 | 2 | 3 |
2 | 7 | 2004.04 | 54 | 15.11 | 3119 | 2545 | 2.75 / 353.31 | 2 | 3 |
3 | 13 | 869.36 | 16 | 15.11 | 1598 | 386 | 3.14 / 353.70 | 2 | 4 |
4 | 13 | 326.52 | 16 | 15.20 | 819 | 199 | 3.34 / 353.90 | 2 | 4 |
5 | 13 | 41.64 | 16 | 15.25 | 381 | 93 | 3.43 / 353.99 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.22 | 306 | 768 | 4.20 / 354.76 | 2 | 8 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 29 | 15.17 | 458 | 201 | 0.20 / 346.53 | 2 | 3 |
2 | 7 | 2006.28 | 53 | 15.09 | 3125 | 2499 | 2.70 / 349.03 | 2 | 3 |
3 | 13 | 907.68 | 16 | 15.08 | 1650 | 398 | 3.10 / 349.43 | 2 | 3 |
4 | 13 | 482.40 | 16 | 15.15 | 1048 | 254 | 3.35 / 349.68 | 2 | 3 |
5 | 13 | 80.92 | 16 | 15.23 | 447 | 109 | 3.46 / 349.79 | 2 | 4 |
6 | 8 | 0.20 | 165 | 15.21 | 307 | 770 | 4.23 / 350.56 | 2 | 14 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 29 | 15.17 | 453 | 199 | 0.20 / 342.31 | 2 | 3 |
2 | 7 | 2003.52 | 53 | 15.10 | 3114 | 2492 | 2.69 / 344.81 | 2 | 3 |
3 | 13 | 885.20 | 16 | 15.09 | 1615 | 390 | 3.08 / 345.20 | 2 | 4 |
4 | 13 | 461.20 | 16 | 15.16 | 1017 | 247 | 3.33 / 345.44 | 2 | 3 |
5 | 13 | 73.68 | 16 | 15.25 | 434 | 106 | 3.43 / 345.55 | 2 | 6 |
6 | 8 | -0.04 | 165 | 15.22 | 310 | 779 | 4.21 / 346.33 | 2 | 4 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.12 | 29 | 15.17 | 489 | 215 | 0.22 / 338.12 | 2 | 3 |
2 | 7 | 2007.92 | 52 | 15.11 | 3130 | 2459 | 2.67 / 340.58 | 2 | 3 |
3 | 13 | 1005.96 | 16 | 15.07 | 1782 | 430 | 3.10 / 341.00 | 2 | 3 |
4 | 13 | 426.60 | 16 | 15.17 | 975 | 237 | 3.34 / 341.24 | 2 | 4 |
5 | 13 | 64.68 | 16 | 15.25 | 420 | 102 | 3.44 / 341.34 | 2 | 5 |
6 | 8 | 0.16 | 165 | 15.22 | 307 | 771 | 4.21 / 342.12 | 2 | 6 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.08 | 29 | 15.19 | 484 | 213 | 0.21 / 333.90 | 2 | 3 |
2 | 7 | 2005.00 | 53 | 15.10 | 3121 | 2498 | 2.71 / 336.40 | 2 | 3 |
3 | 13 | 877.92 | 16 | 15.09 | 1608 | 388 | 3.10 / 336.79 | 2 | 3 |
4 | 13 | 446.60 | 16 | 15.16 | 996 | 242 | 3.34 / 337.03 | 2 | 4 |
5 | 13 | 63.60 | 16 | 15.24 | 413 | 101 | 3.44 / 337.13 | 2 | 4 |
6 | 8 | 0.12 | 165 | 15.22 | 306 | 768 | 4.21 / 337.90 | 2 | 6 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.88 | 29 | 15.16 | 477 | 210 | 0.21 / 329.66 | 2 | 3 |
2 | 7 | 2003.72 | 53 | 15.11 | 3125 | 2503 | 2.71 / 332.17 | 2 | 3 |
3 | 13 | 997.16 | 16 | 15.08 | 1771 | 427 | 3.14 / 332.59 | 2 | 4 |
4 | 13 | 430.04 | 16 | 15.18 | 971 | 236 | 3.38 / 332.83 | 2 | 3 |
5 | 13 | 67.60 | 16 | 15.26 | 420 | 103 | 3.48 / 332.93 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.23 | 302 | 759 | 4.24 / 333.69 | 2 | 7 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 29 | 15.19 | 460 | 203 | 0.20 / 325.07 | 2 | 3 |
2 | 7 | 2012.28 | 53 | 15.09 | 3132 | 2505 | 2.71 / 327.58 | 2 | 3 |
3 | 13 | 1003.12 | 16 | 15.07 | 1784 | 430 | 3.14 / 328.01 | 2 | 4 |
4 | 13 | 430.12 | 16 | 15.17 | 974 | 236 | 3.37 / 328.24 | 2 | 4 |
5 | 13 | 62.68 | 16 | 15.26 | 417 | 102 | 3.48 / 328.34 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.23 | 305 | 766 | 4.24 / 329.11 | 2 | 5 |
7 | 14 | -0.08 | 75 | 15.19 | 301 | 343 | 4.59 / 329.45 | 3 | 16 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.00 | 29 | 15.20 | 492 | 217 | 0.22 / 320.85 | 2 | 3 |
2 | 7 | 2008.44 | 53 | 15.11 | 3128 | 2505 | 2.72 / 323.35 | 2 | 2 |
3 | 13 | 880.80 | 16 | 15.12 | 1614 | 390 | 3.11 / 323.74 | 2 | 3 |
4 | 13 | 458.84 | 16 | 15.19 | 1011 | 246 | 3.36 / 323.99 | 2 | 4 |
5 | 13 | 71.80 | 16 | 15.27 | 438 | 107 | 3.47 / 324.09 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.24 | 308 | 774 | 4.24 / 324.87 | 2 | 15 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.92 | 29 | 15.20 | 487 | 215 | 0.21 / 316.66 | 2 | 3 |
2 | 7 | 2005.84 | 52 | 15.12 | 3132 | 2463 | 2.68 / 319.12 | 2 | 3 |
3 | 13 | 882.48 | 16 | 15.12 | 1608 | 389 | 3.07 / 319.51 | 2 | 3 |
4 | 13 | 464.60 | 16 | 15.19 | 1016 | 247 | 3.31 / 319.76 | 2 | 3 |
5 | 13 | 71.44 | 16 | 15.27 | 426 | 104 | 3.42 / 319.86 | 2 | 4 |
6 | 8 | 0.12 | 165 | 15.25 | 305 | 767 | 4.18 / 320.63 | 2 | 10 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 29 | 15.20 | 489 | 216 | 0.22 / 312.46 | 2 | 3 |
2 | 7 | 2005.92 | 52 | 15.11 | 3123 | 2454 | 2.67 / 314.91 | 2 | 2 |
3 | 13 | 1003.16 | 16 | 15.09 | 1777 | 429 | 3.10 / 315.34 | 2 | 3 |
4 | 13 | 424.88 | 16 | 15.19 | 960 | 233 | 3.33 / 315.57 | 2 | 4 |
5 | 13 | 65.24 | 16 | 15.28 | 416 | 102 | 3.43 / 315.67 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.25 | 306 | 770 | 4.20 / 316.44 | 2 | 8 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.80 | 29 | 15.20 | 483 | 213 | 0.21 / 308.19 | 2 | 3 |
2 | 7 | 2011.04 | 53 | 15.12 | 3134 | 2511 | 2.72 / 310.70 | 2 | 3 |
3 | 13 | 1011.40 | 16 | 15.10 | 1787 | 432 | 3.16 / 311.13 | 2 | 3 |
4 | 13 | 442.64 | 16 | 15.20 | 987 | 240 | 3.40 / 311.37 | 2 | 4 |
5 | 13 | 72.16 | 16 | 15.28 | 427 | 104 | 3.50 / 311.48 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.25 | 304 | 765 | 4.27 / 312.24 | 2 | 9 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.00 | 29 | 15.21 | 492 | 217 | 0.22 / 303.93 | 2 | 3 |
2 | 7 | 2009.80 | 53 | 15.12 | 3123 | 2503 | 2.72 / 306.43 | 2 | 3 |
3 | 13 | 1010.40 | 16 | 15.10 | 1791 | 433 | 3.15 / 306.87 | 2 | 4 |
4 | 13 | 438.76 | 16 | 15.19 | 976 | 237 | 3.39 / 307.10 | 2 | 3 |
5 | 13 | 67.08 | 16 | 15.27 | 422 | 103 | 3.49 / 307.21 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.25 | 306 | 770 | 4.26 / 307.98 | 2 | 5 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 29 | 15.22 | 489 | 216 | 0.22 / 299.69 | 2 | 3 |
2 | 7 | 2011.00 | 53 | 15.12 | 3132 | 2510 | 2.73 / 302.20 | 2 | 3 |
3 | 13 | 891.04 | 16 | 15.12 | 1622 | 392 | 3.12 / 302.59 | 2 | 3 |
4 | 13 | 467.44 | 16 | 15.19 | 1022 | 248 | 3.37 / 302.84 | 2 | 4 |
5 | 13 | 78.72 | 16 | 15.28 | 438 | 107 | 3.47 / 302.95 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.26 | 304 | 765 | 4.24 / 303.71 | 2 | 5 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.36 | 29 | 15.21 | 499 | 220 | 0.22 / 295.44 | 2 | 3 |
2 | 7 | 2004.76 | 53 | 15.12 | 3115 | 2496 | 2.72 / 297.93 | 2 | 3 |
3 | 13 | 1000.24 | 16 | 15.10 | 1775 | 429 | 3.15 / 298.36 | 2 | 3 |
4 | 13 | 426.52 | 16 | 15.21 | 966 | 235 | 3.38 / 298.60 | 2 | 3 |
5 | 13 | 66.40 | 16 | 15.28 | 423 | 103 | 3.48 / 298.70 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.26 | 307 | 773 | 4.26 / 299.47 | 2 | 11 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 29 | 15.22 | 473 | 209 | 0.21 / 291.20 | 2 | 3 |
2 | 7 | 2004.80 | 54 | 15.12 | 3116 | 2544 | 2.75 / 293.74 | 2 | 3 |
3 | 13 | 879.64 | 16 | 15.12 | 1601 | 387 | 3.14 / 294.13 | 2 | 3 |
4 | 13 | 331.00 | 16 | 15.22 | 823 | 200 | 3.34 / 294.33 | 2 | 4 |
5 | 13 | 87.40 | 16 | 15.28 | 459 | 112 | 3.45 / 294.44 | 2 | 5 |
6 | 8 | -0.04 | 165 | 15.26 | 308 | 776 | 4.23 / 295.22 | 2 | 6 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.92 | 29 | 15.22 | 490 | 216 | 0.22 / 286.99 | 2 | 2 |
2 | 7 | 2008.68 | 52 | 15.12 | 3124 | 2456 | 2.67 / 289.44 | 2 | 3 |
3 | 13 | 1003.28 | 16 | 15.11 | 1774 | 429 | 3.10 / 289.87 | 2 | 3 |
4 | 13 | 434.00 | 16 | 15.22 | 975 | 237 | 3.34 / 290.11 | 2 | 4 |
5 | 13 | 64.32 | 16 | 15.30 | 414 | 101 | 3.44 / 290.21 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.27 | 309 | 779 | 4.22 / 290.99 | 2 | 9 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 29 | 15.23 | 495 | 219 | 0.22 / 282.77 | 2 | 3 |
2 | 7 | 2002.80 | 52 | 15.13 | 3126 | 2459 | 2.68 / 285.23 | 2 | 3 |
3 | 13 | 994.96 | 16 | 15.12 | 1763 | 427 | 3.10 / 285.65 | 2 | 3 |
4 | 13 | 422.40 | 16 | 15.23 | 956 | 233 | 3.34 / 285.89 | 2 | 3 |
5 | 13 | 66.44 | 16 | 15.29 | 423 | 103 | 3.44 / 285.99 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.27 | 310 | 781 | 4.22 / 286.77 | 2 | 8 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.44 | 29 | 15.24 | 495 | 219 | 0.22 / 278.51 | 2 | 3 |
2 | 7 | 2010.76 | 53 | 15.13 | 3115 | 2498 | 2.72 / 281.00 | 2 | 3 |
3 | 13 | 1002.84 | 16 | 15.12 | 1772 | 429 | 3.15 / 281.43 | 2 | 4 |
4 | 13 | 426.24 | 16 | 15.23 | 964 | 235 | 3.38 / 281.67 | 2 | 3 |
5 | 13 | 62.56 | 16 | 15.31 | 417 | 102 | 3.48 / 281.77 | 2 | 5 |
6 | 8 | 0.20 | 165 | 15.28 | 309 | 779 | 4.26 / 282.55 | 2 | 4 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.08 | 29 | 15.24 | 496 | 219 | 0.22 / 274.32 | 2 | 3 |
2 | 7 | 2002.96 | 52 | 15.13 | 3121 | 2455 | 2.67 / 276.77 | 2 | 3 |
3 | 13 | 879.36 | 16 | 15.16 | 1601 | 388 | 3.06 / 277.16 | 2 | 4 |
4 | 13 | 457.88 | 16 | 15.23 | 1012 | 247 | 3.31 / 277.41 | 2 | 3 |
5 | 13 | 71.44 | 16 | 15.32 | 432 | 106 | 3.42 / 277.51 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.29 | 307 | 775 | 4.19 / 278.29 | 2 | 6 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.36 | 28 | 15.24 | 495 | 211 | 0.21 / 270.07 | 2 | 2 |
2 | 7 | 2011.56 | 53 | 15.13 | 3128 | 2508 | 2.72 / 272.58 | 2 | 2 |
3 | 13 | 887.08 | 16 | 15.16 | 1613 | 391 | 3.11 / 272.97 | 2 | 3 |
4 | 13 | 456.04 | 16 | 15.23 | 1003 | 244 | 3.36 / 273.22 | 2 | 4 |
5 | 13 | 70.04 | 16 | 15.32 | 431 | 106 | 3.46 / 273.32 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.30 | 306 | 772 | 4.23 / 274.10 | 2 | 8 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 28 | 15.25 | 470 | 201 | 0.20 / 265.79 | 2 | 3 |
2 | 7 | 2008.00 | 53 | 15.14 | 3132 | 2513 | 2.71 / 268.31 | 2 | 3 |
3 | 13 | 1000.12 | 16 | 15.12 | 1772 | 429 | 3.14 / 268.74 | 2 | 4 |
4 | 13 | 438.48 | 16 | 15.23 | 983 | 240 | 3.38 / 268.98 | 2 | 3 |
5 | 13 | 65.36 | 16 | 15.31 | 423 | 104 | 3.49 / 269.08 | 2 | 5 |
6 | 8 | 0.16 | 165 | 15.29 | 311 | 785 | 4.27 / 269.86 | 2 | 7 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 28 | 15.25 | 486 | 208 | 0.21 / 261.55 | 2 | 3 |
2 | 7 | 2004.20 | 53 | 15.14 | 3119 | 2503 | 2.71 / 264.05 | 2 | 3 |
3 | 13 | 995.84 | 16 | 15.13 | 1766 | 428 | 3.14 / 264.48 | 2 | 4 |
4 | 13 | 426.04 | 16 | 15.25 | 965 | 235 | 3.37 / 264.71 | 2 | 4 |
5 | 13 | 60.76 | 16 | 15.33 | 415 | 102 | 3.48 / 264.82 | 2 | 3 |
6 | 8 | -0.16 | 165 | 15.30 | 308 | 778 | 4.25 / 265.59 | 2 | 7 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.44 | 28 | 15.27 | 489 | 209 | 0.21 / 256.88 | 2 | 3 |
2 | 7 | 2006.16 | 54 | 15.15 | 3128 | 2559 | 2.77 / 259.44 | 2 | 3 |
3 | 13 | 1002.12 | 16 | 15.14 | 1775 | 430 | 3.20 / 259.87 | 2 | 4 |
4 | 13 | 410.52 | 16 | 15.26 | 942 | 230 | 3.43 / 260.10 | 2 | 3 |
5 | 13 | 55.24 | 16 | 15.34 | 406 | 100 | 3.53 / 260.20 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.31 | 312 | 788 | 4.32 / 260.98 | 2 | 7 |
7 | 14 | 0.16 | 75 | 15.27 | 311 | 356 | 4.67 / 261.34 | 3 | 13 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 28 | 15.26 | 496 | 212 | 0.21 / 252.64 | 2 | 3 |
2 | 7 | 2002.92 | 53 | 15.14 | 3117 | 2501 | 2.71 / 255.14 | 2 | 3 |
3 | 13 | 987.44 | 16 | 15.15 | 1752 | 425 | 3.14 / 255.57 | 2 | 4 |
4 | 13 | 421.84 | 16 | 15.27 | 961 | 235 | 3.37 / 255.80 | 2 | 4 |
5 | 13 | 31.16 | 16 | 15.36 | 366 | 90 | 3.46 / 255.89 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.32 | 307 | 776 | 4.24 / 256.67 | 2 | 10 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 28 | 15.26 | 493 | 211 | 0.21 / 248.41 | 2 | 3 |
2 | 7 | 2008.08 | 53 | 15.15 | 3127 | 2511 | 2.72 / 250.92 | 2 | 3 |
3 | 13 | 891.60 | 16 | 15.17 | 1623 | 394 | 3.12 / 251.31 | 2 | 4 |
4 | 13 | 462.80 | 16 | 15.24 | 1013 | 247 | 3.36 / 251.56 | 2 | 3 |
5 | 13 | 35.28 | 16 | 15.34 | 372 | 91 | 3.45 / 251.65 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.31 | 309 | 781 | 4.23 / 252.43 | 2 | 5 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 28 | 15.27 | 488 | 209 | 0.21 / 244.23 | 2 | 3 |
2 | 7 | 2005.88 | 52 | 15.15 | 3110 | 2450 | 2.66 / 246.68 | 2 | 2 |
3 | 13 | 883.00 | 16 | 15.19 | 1619 | 393 | 3.05 / 247.07 | 2 | 4 |
4 | 13 | 457.40 | 16 | 15.26 | 1010 | 247 | 3.30 / 247.32 | 2 | 4 |
5 | 13 | 37.24 | 16 | 15.36 | 380 | 93 | 3.39 / 247.41 | 2 | 5 |
6 | 8 | 0.16 | 165 | 15.32 | 310 | 784 | 4.18 / 248.20 | 2 | 14 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 28 | 15.28 | 495 | 212 | 0.21 / 239.98 | 2 | 3 |
2 | 7 | 2005.00 | 53 | 15.16 | 3118 | 2505 | 2.72 / 242.49 | 2 | 3 |
3 | 13 | 888.88 | 16 | 15.18 | 1621 | 394 | 3.11 / 242.88 | 2 | 3 |
4 | 13 | 458.04 | 16 | 15.27 | 1015 | 248 | 3.36 / 243.13 | 2 | 3 |
5 | 13 | 65.24 | 16 | 15.34 | 425 | 104 | 3.46 / 243.24 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.33 | 310 | 784 | 4.25 / 244.02 | 2 | 10 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 28 | 15.27 | 487 | 208 | 0.21 / 235.74 | 2 | 3 |
2 | 7 | 2002.88 | 53 | 15.17 | 3122 | 2510 | 2.72 / 238.25 | 2 | 3 |
3 | 13 | 875.40 | 16 | 15.21 | 1601 | 390 | 3.11 / 238.64 | 2 | 3 |
4 | 13 | 451.52 | 16 | 15.29 | 1003 | 245 | 3.35 / 238.89 | 2 | 3 |
5 | 13 | 66.72 | 16 | 15.36 | 423 | 104 | 3.46 / 238.99 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.34 | 309 | 782 | 4.24 / 239.77 | 2 | 4 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.04 | 28 | 15.28 | 489 | 209 | 0.21 / 231.49 | 2 | 3 |
2 | 7 | 2002.96 | 53 | 15.16 | 3122 | 2508 | 2.72 / 234.00 | 2 | 3 |
3 | 13 | 994.84 | 16 | 15.17 | 1760 | 427 | 3.14 / 234.43 | 2 | 4 |
4 | 13 | 434.60 | 16 | 15.28 | 978 | 239 | 3.38 / 234.67 | 2 | 4 |
5 | 13 | 64.28 | 16 | 15.36 | 414 | 102 | 3.49 / 234.77 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.33 | 303 | 766 | 4.25 / 235.53 | 2 | 11 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 28 | 15.29 | 465 | 199 | 0.20 / 227.26 | 2 | 3 |
2 | 7 | 2003.12 | 53 | 15.17 | 3113 | 2503 | 2.70 / 229.77 | 2 | 3 |
3 | 13 | 889.36 | 16 | 15.20 | 1622 | 394 | 3.10 / 230.16 | 2 | 4 |
4 | 13 | 461.56 | 16 | 15.28 | 1015 | 248 | 3.34 / 230.41 | 2 | 4 |
5 | 13 | 41.60 | 16 | 15.36 | 380 | 93 | 3.44 / 230.50 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.34 | 308 | 780 | 4.22 / 231.28 | 2 | 9 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 28 | 15.30 | 464 | 199 | 0.20 / 223.05 | 2 | 3 |
2 | 7 | 2003.40 | 53 | 15.17 | 3111 | 2501 | 2.70 / 225.55 | 2 | 2 |
3 | 13 | 877.48 | 16 | 15.19 | 1601 | 389 | 3.09 / 225.94 | 2 | 4 |
4 | 13 | 445.96 | 16 | 15.28 | 993 | 243 | 3.33 / 226.18 | 2 | 4 |
5 | 13 | 68.48 | 16 | 15.37 | 424 | 104 | 3.44 / 226.28 | 2 | 5 |
6 | 8 | 0.04 | 165 | 15.33 | 308 | 779 | 4.22 / 227.06 | 2 | 11 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 28 | 15.28 | 452 | 193 | 0.19 / 218.80 | 2 | 3 |
2 | 7 | 2003.00 | 53 | 15.18 | 3118 | 2509 | 2.70 / 221.30 | 2 | 3 |
3 | 13 | 991.32 | 16 | 15.19 | 1757 | 427 | 3.13 / 221.73 | 2 | 3 |
4 | 13 | 410.04 | 16 | 15.31 | 939 | 230 | 3.36 / 221.96 | 2 | 4 |
5 | 13 | 64.08 | 16 | 15.37 | 417 | 103 | 3.46 / 222.06 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.34 | 310 | 785 | 4.25 / 222.85 | 2 | 10 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.84 | 28 | 15.29 | 483 | 207 | 0.21 / 214.57 | 2 | 3 |
2 | 7 | 2010.84 | 53 | 15.16 | 3117 | 2504 | 2.71 / 217.08 | 2 | 2 |
3 | 13 | 891.68 | 16 | 15.20 | 1620 | 394 | 3.11 / 217.47 | 2 | 3 |
4 | 13 | 460.76 | 16 | 15.28 | 1013 | 248 | 3.35 / 217.72 | 2 | 4 |
5 | 13 | 76.96 | 16 | 15.36 | 442 | 109 | 3.46 / 217.83 | 2 | 5 |
6 | 8 | 0.12 | 165 | 15.34 | 306 | 775 | 4.24 / 218.60 | 2 | 4 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.52 | 28 | 15.28 | 481 | 206 | 0.21 / 210.38 | 2 | 3 |
2 | 7 | 2003.16 | 52 | 15.17 | 3105 | 2449 | 2.66 / 212.83 | 2 | 3 |
3 | 13 | 991.28 | 16 | 15.18 | 1759 | 427 | 3.08 / 213.26 | 2 | 3 |
4 | 13 | 416.80 | 16 | 15.29 | 950 | 232 | 3.31 / 213.49 | 2 | 3 |
5 | 13 | 64.84 | 16 | 15.37 | 418 | 103 | 3.42 / 213.59 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.34 | 305 | 772 | 4.19 / 214.37 | 2 | 5 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 28 | 15.30 | 449 | 192 | 0.19 / 205.79 | 2 | 3 |
2 | 7 | 2011.84 | 53 | 15.17 | 3120 | 2509 | 2.70 / 208.30 | 2 | 3 |
3 | 13 | 996.08 | 16 | 15.19 | 1767 | 429 | 3.13 / 208.73 | 2 | 4 |
4 | 13 | 420.76 | 16 | 15.30 | 955 | 234 | 3.36 / 208.96 | 2 | 4 |
5 | 13 | 62.52 | 16 | 15.38 | 412 | 101 | 3.47 / 209.07 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.35 | 302 | 765 | 4.23 / 209.83 | 2 | 10 |
7 | 14 | 0.16 | 75 | 15.32 | 301 | 346 | 4.58 / 210.18 | 3 | 8 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.88 | 28 | 15.30 | 474 | 203 | 0.20 / 201.56 | 2 | 3 |
2 | 7 | 2005.80 | 53 | 15.17 | 3119 | 2508 | 2.71 / 204.07 | 2 | 3 |
3 | 13 | 999.08 | 16 | 15.19 | 1766 | 429 | 3.14 / 204.50 | 2 | 4 |
4 | 13 | 423.96 | 16 | 15.31 | 959 | 235 | 3.37 / 204.73 | 2 | 3 |
5 | 13 | 60.72 | 16 | 15.39 | 409 | 101 | 3.48 / 204.83 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.35 | 303 | 767 | 4.24 / 205.60 | 2 | 4 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 28 | 15.30 | 449 | 192 | 0.19 / 197.44 | 2 | 3 |
2 | 7 | 2006.80 | 52 | 15.18 | 3117 | 2460 | 2.65 / 199.91 | 2 | 3 |
3 | 13 | 877.60 | 16 | 15.21 | 1599 | 389 | 3.04 / 200.29 | 2 | 3 |
4 | 13 | 337.84 | 16 | 15.32 | 832 | 204 | 3.25 / 200.50 | 2 | 3 |
5 | 13 | 51.64 | 16 | 15.38 | 393 | 97 | 3.34 / 200.59 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.35 | 301 | 762 | 4.10 / 201.36 | 2 | 4 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.44 | 28 | 15.31 | 476 | 204 | 0.20 / 193.24 | 2 | 3 |
2 | 7 | 2006.48 | 53 | 15.16 | 3115 | 2503 | 2.71 / 195.74 | 2 | 3 |
3 | 13 | 880.44 | 16 | 15.21 | 1602 | 390 | 3.10 / 196.13 | 2 | 3 |
4 | 13 | 460.84 | 16 | 15.30 | 1007 | 247 | 3.34 / 196.38 | 2 | 3 |
5 | 13 | 75.28 | 16 | 15.38 | 433 | 107 | 3.45 / 196.49 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.35 | 302 | 765 | 4.21 / 197.25 | 2 | 9 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.28 | 28 | 15.30 | 479 | 205 | 0.21 / 189.00 | 2 | 3 |
2 | 7 | 2010.12 | 53 | 15.18 | 3115 | 2506 | 2.71 / 191.50 | 2 | 2 |
3 | 13 | 1007.40 | 16 | 15.19 | 1767 | 429 | 3.14 / 191.93 | 2 | 3 |
4 | 13 | 426.36 | 16 | 15.32 | 959 | 235 | 3.38 / 192.17 | 2 | 3 |
5 | 13 | 63.92 | 16 | 15.39 | 413 | 102 | 3.48 / 192.27 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.36 | 303 | 768 | 4.25 / 193.04 | 2 | 11 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.28 | 28 | 15.32 | 469 | 201 | 0.20 / 184.78 | 2 | 3 |
2 | 7 | 2006.44 | 53 | 15.17 | 3114 | 2504 | 2.70 / 187.28 | 2 | 2 |
3 | 13 | 886.48 | 16 | 15.22 | 1612 | 393 | 3.10 / 187.67 | 2 | 3 |
4 | 13 | 463.44 | 16 | 15.29 | 1014 | 248 | 3.35 / 187.92 | 2 | 3 |
5 | 13 | 76.24 | 16 | 15.38 | 435 | 107 | 3.45 / 188.03 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.35 | 301 | 762 | 4.21 / 188.79 | 2 | 4 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.60 | 28 | 15.31 | 487 | 209 | 0.21 / 180.57 | 2 | 3 |
2 | 7 | 2003.72 | 53 | 15.19 | 3099 | 2495 | 2.70 / 183.06 | 2 | 2 |
3 | 13 | 989.60 | 16 | 15.20 | 1753 | 426 | 3.13 / 183.49 | 2 | 4 |
4 | 13 | 417.84 | 16 | 15.32 | 944 | 231 | 3.36 / 183.72 | 2 | 3 |
5 | 13 | 62.32 | 16 | 15.38 | 408 | 100 | 3.46 / 183.82 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.36 | 299 | 758 | 4.22 / 184.58 | 2 | 3 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.72 | 28 | 15.32 | 487 | 209 | 0.21 / 176.27 | 2 | 3 |
2 | 7 | 2002.08 | 53 | 15.18 | 3108 | 2501 | 2.71 / 178.77 | 2 | 2 |
3 | 13 | 1000.84 | 16 | 15.20 | 1773 | 431 | 3.14 / 179.20 | 2 | 3 |
4 | 13 | 554.04 | 16 | 15.28 | 1141 | 279 | 3.42 / 179.48 | 2 | 4 |
5 | 13 | 57.00 | 16 | 15.39 | 402 | 99 | 3.52 / 179.58 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.36 | 306 | 776 | 4.29 / 180.36 | 2 | 7 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 28 | 15.33 | 478 | 205 | 0.21 / 172.16 | 2 | 3 |
2 | 7 | 2003.16 | 52 | 15.19 | 3105 | 2453 | 2.66 / 174.61 | 2 | 2 |
3 | 13 | 885.24 | 16 | 15.23 | 1607 | 392 | 3.05 / 175.00 | 2 | 3 |
4 | 13 | 340.20 | 16 | 15.35 | 836 | 205 | 3.25 / 175.21 | 2 | 4 |
5 | 13 | 48.80 | 16 | 15.41 | 390 | 96 | 3.35 / 175.30 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.37 | 300 | 761 | 4.11 / 176.06 | 2 | 12 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.36 | 28 | 15.32 | 485 | 208 | 0.21 / 167.93 | 2 | 3 |
2 | 7 | 2006.24 | 53 | 15.18 | 3119 | 2509 | 2.72 / 170.44 | 2 | 3 |
3 | 13 | 878.24 | 16 | 15.23 | 1597 | 389 | 3.11 / 170.83 | 2 | 4 |
4 | 13 | 452.40 | 16 | 15.31 | 994 | 243 | 3.35 / 171.07 | 2 | 4 |
5 | 13 | 69.12 | 16 | 15.39 | 422 | 104 | 3.45 / 171.18 | 2 | 4 |
6 | 8 | 0.20 | 165 | 15.36 | 306 | 776 | 4.23 / 171.95 | 2 | 9 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.44 | 28 | 15.33 | 481 | 206 | 0.21 / 163.68 | 2 | 3 |
2 | 7 | 2002.44 | 53 | 15.20 | 3111 | 2506 | 2.71 / 166.19 | 2 | 2 |
3 | 13 | 988.96 | 16 | 15.22 | 1748 | 426 | 3.14 / 166.61 | 2 | 4 |
4 | 13 | 407.60 | 16 | 15.33 | 939 | 230 | 3.37 / 166.85 | 2 | 4 |
5 | 13 | 59.68 | 16 | 15.41 | 411 | 101 | 3.47 / 166.95 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.37 | 306 | 776 | 4.25 / 167.72 | 2 | 6 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.20 | 28 | 15.32 | 488 | 209 | 0.21 / 159.50 | 2 | 3 |
2 | 7 | 2002.64 | 53 | 15.19 | 3114 | 2507 | 2.72 / 162.00 | 2 | 3 |
3 | 13 | 878.40 | 16 | 15.23 | 1595 | 389 | 3.10 / 162.39 | 2 | 3 |
4 | 13 | 333.52 | 16 | 15.35 | 830 | 204 | 3.31 / 162.59 | 2 | 3 |
5 | 13 | 89.56 | 16 | 15.39 | 461 | 114 | 3.42 / 162.71 | 2 | 6 |
6 | 8 | -0.12 | 165 | 15.37 | 303 | 768 | 4.19 / 163.48 | 2 | 6 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.28 | 28 | 15.34 | 487 | 209 | 0.21 / 155.25 | 2 | 3 |
2 | 7 | 2004.04 | 53 | 15.19 | 3113 | 2506 | 2.72 / 157.75 | 2 | 3 |
3 | 13 | 986.04 | 16 | 15.22 | 1745 | 425 | 3.14 / 158.18 | 2 | 4 |
4 | 13 | 413.80 | 16 | 15.33 | 940 | 231 | 3.37 / 158.41 | 2 | 3 |
5 | 13 | 58.88 | 16 | 15.40 | 404 | 100 | 3.47 / 158.51 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.37 | 306 | 776 | 4.25 / 159.29 | 2 | 12 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.28 | 28 | 15.34 | 495 | 213 | 0.21 / 151.06 | 2 | 3 |
2 | 7 | 2009.12 | 53 | 15.19 | 3126 | 2517 | 2.73 / 153.58 | 2 | 3 |
3 | 13 | 873.12 | 16 | 15.25 | 1595 | 389 | 3.12 / 153.97 | 2 | 3 |
4 | 13 | 333.04 | 16 | 15.36 | 828 | 203 | 3.32 / 154.17 | 2 | 4 |
5 | 13 | 45.08 | 16 | 15.41 | 384 | 95 | 3.42 / 154.27 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.38 | 304 | 771 | 4.19 / 155.04 | 2 | 9 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.04 | 28 | 15.33 | 490 | 210 | 0.21 / 146.86 | 2 | 3 |
2 | 7 | 2003.24 | 52 | 15.20 | 3105 | 2454 | 2.66 / 149.31 | 2 | 2 |
3 | 13 | 986.44 | 16 | 15.22 | 1749 | 426 | 3.09 / 149.74 | 2 | 3 |
4 | 13 | 418.44 | 16 | 15.35 | 945 | 232 | 3.32 / 149.97 | 2 | 4 |
5 | 13 | 62.64 | 16 | 15.42 | 413 | 102 | 3.42 / 150.07 | 2 | 6 |
6 | 8 | 0.08 | 165 | 15.39 | 307 | 780 | 4.20 / 150.85 | 2 | 3 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.64 | 28 | 15.34 | 484 | 208 | 0.21 / 142.67 | 2 | 3 |
2 | 7 | 2003.88 | 53 | 15.20 | 3093 | 2492 | 2.70 / 145.16 | 2 | 2 |
3 | 13 | 859.80 | 16 | 15.24 | 1572 | 383 | 3.08 / 145.54 | 2 | 3 |
4 | 13 | 431.00 | 16 | 15.33 | 963 | 236 | 3.32 / 145.78 | 2 | 3 |
5 | 13 | 58.32 | 16 | 15.41 | 403 | 99 | 3.42 / 145.88 | 2 | 4 |
6 | 8 | 0.12 | 165 | 15.38 | 303 | 769 | 4.19 / 146.65 | 2 | 11 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.64 | 28 | 15.33 | 493 | 212 | 0.21 / 138.49 | 2 | 2 |
2 | 7 | 2004.16 | 52 | 15.21 | 3113 | 2462 | 2.67 / 140.95 | 2 | 2 |
3 | 13 | 880.00 | 16 | 15.25 | 1597 | 390 | 3.06 / 141.34 | 2 | 3 |
4 | 13 | 456.92 | 16 | 15.32 | 1000 | 245 | 3.31 / 141.58 | 2 | 4 |
5 | 13 | 72.60 | 16 | 15.40 | 433 | 107 | 3.42 / 141.69 | 2 | 5 |
6 | 8 | 0.12 | 165 | 15.39 | 303 | 769 | 4.18 / 142.46 | 2 | 6 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 28 | 15.34 | 486 | 209 | 0.21 / 134.24 | 2 | 3 |
2 | 7 | 2009.56 | 53 | 15.20 | 3118 | 2512 | 2.72 / 136.76 | 2 | 2 |
3 | 13 | 874.44 | 16 | 15.25 | 1592 | 388 | 3.11 / 137.15 | 2 | 3 |
4 | 13 | 457.44 | 16 | 15.33 | 1003 | 246 | 3.36 / 137.39 | 2 | 4 |
5 | 13 | 70.72 | 16 | 15.41 | 425 | 105 | 3.46 / 137.50 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.38 | 307 | 779 | 4.24 / 138.28 | 2 | 8 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.08 | 28 | 15.34 | 496 | 213 | 0.21 / 130.10 | 2 | 3 |
2 | 7 | 2003.76 | 52 | 15.20 | 3093 | 2445 | 2.66 / 132.54 | 2 | 3 |
3 | 13 | 875.80 | 16 | 15.24 | 1591 | 388 | 3.05 / 132.93 | 2 | 3 |
4 | 13 | 453.08 | 16 | 15.32 | 1001 | 245 | 3.29 / 133.17 | 2 | 3 |
5 | 13 | 33.84 | 16 | 15.42 | 366 | 90 | 3.38 / 133.26 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.38 | 304 | 771 | 4.15 / 134.04 | 2 | 4 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 28 | 15.35 | 484 | 208 | 0.21 / 125.87 | 2 | 3 |
2 | 7 | 2005.08 | 53 | 15.21 | 3112 | 2509 | 2.72 / 128.38 | 2 | 3 |
3 | 13 | 870.16 | 16 | 15.26 | 1591 | 388 | 3.11 / 128.76 | 2 | 3 |
4 | 13 | 442.32 | 16 | 15.34 | 979 | 240 | 3.35 / 129.00 | 2 | 3 |
5 | 13 | 65.52 | 16 | 15.41 | 415 | 102 | 3.45 / 129.11 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.39 | 306 | 777 | 4.22 / 129.88 | 2 | 11 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.88 | 28 | 15.35 | 482 | 207 | 0.21 / 121.69 | 2 | 3 |
2 | 7 | 2011.12 | 53 | 15.20 | 3121 | 2514 | 2.72 / 124.20 | 2 | 3 |
3 | 13 | 885.48 | 16 | 15.25 | 1608 | 392 | 3.11 / 124.59 | 2 | 4 |
4 | 13 | 346.60 | 16 | 15.35 | 840 | 206 | 3.32 / 124.80 | 2 | 4 |
5 | 13 | 50.60 | 16 | 15.41 | 386 | 95 | 3.42 / 124.89 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.39 | 301 | 764 | 4.18 / 125.66 | 2 | 13 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.80 | 28 | 15.34 | 486 | 209 | 0.21 / 117.59 | 2 | 3 |
2 | 7 | 2005.88 | 52 | 15.22 | 3119 | 2469 | 2.68 / 120.06 | 2 | 3 |
3 | 13 | 986.00 | 16 | 15.24 | 1738 | 424 | 3.10 / 120.48 | 2 | 3 |
4 | 13 | 413.08 | 16 | 15.35 | 941 | 231 | 3.33 / 120.71 | 2 | 4 |
5 | 8 | 0.32 | 165 | 15.40 | 302 | 767 | 4.10 / 121.48 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 28 | 15.36 | 465 | 200 | 0.20 / 113.39 | 2 | 3 |
2 | 7 | 2004.32 | 53 | 15.21 | 3106 | 2504 | 2.70 / 115.90 | 2 | 3 |
3 | 13 | 863.88 | 16 | 15.25 | 1567 | 382 | 3.09 / 116.28 | 2 | 4 |
4 | 13 | 435.56 | 16 | 15.34 | 970 | 238 | 3.32 / 116.52 | 2 | 4 |
5 | 13 | 62.16 | 16 | 15.42 | 411 | 101 | 3.43 / 116.62 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.40 | 300 | 762 | 4.19 / 117.38 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 28 | 15.36 | 486 | 209 | 0.21 / 109.16 | 2 | 3 |
2 | 7 | 2002.28 | 53 | 15.23 | 3098 | 2501 | 2.71 / 111.66 | 2 | 2 |
3 | 13 | 987.68 | 16 | 15.25 | 1746 | 426 | 3.14 / 112.09 | 2 | 3 |
4 | 13 | 417.96 | 16 | 15.37 | 952 | 234 | 3.37 / 112.32 | 2 | 3 |
5 | 13 | 64.56 | 16 | 15.42 | 413 | 102 | 3.47 / 112.42 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.40 | 302 | 767 | 4.24 / 113.19 | 2 | 11 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 28 | 15.36 | 487 | 209 | 0.21 / 104.93 | 2 | 3 |
2 | 7 | 2009.60 | 53 | 15.23 | 3116 | 2515 | 2.72 / 107.45 | 2 | 3 |
3 | 13 | 885.12 | 16 | 15.27 | 1605 | 392 | 3.12 / 107.84 | 2 | 3 |
4 | 13 | 457.08 | 16 | 15.35 | 997 | 245 | 3.36 / 108.09 | 2 | 4 |
5 | 13 | 76.00 | 16 | 15.43 | 426 | 105 | 3.47 / 108.19 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.41 | 299 | 760 | 4.23 / 108.95 | 2 | 6 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 28 | 15.38 | 480 | 207 | 0.21 / 100.71 | 2 | 3 |
2 | 7 | 2003.96 | 53 | 15.23 | 3112 | 2512 | 2.72 / 103.22 | 2 | 3 |
3 | 13 | 871.28 | 16 | 15.29 | 1583 | 387 | 3.11 / 103.61 | 2 | 3 |
4 | 13 | 448.80 | 16 | 15.36 | 992 | 244 | 3.35 / 103.85 | 2 | 3 |
5 | 13 | 68.40 | 16 | 15.44 | 417 | 103 | 3.45 / 103.96 | 2 | 4 |
6 | 8 | 0.12 | 165 | 15.41 | 302 | 768 | 4.22 / 104.73 | 2 | 10 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 28 | 15.36 | 450 | 194 | 0.19 / 96.58 | 2 | 3 |
2 | 7 | 2003.20 | 52 | 15.23 | 3111 | 2464 | 2.66 / 99.04 | 2 | 3 |
3 | 13 | 862.80 | 16 | 15.29 | 1577 | 386 | 3.04 / 99.43 | 2 | 3 |
4 | 13 | 319.80 | 16 | 15.40 | 801 | 197 | 3.24 / 99.62 | 2 | 4 |
5 | 13 | 85.00 | 16 | 15.44 | 449 | 111 | 3.35 / 99.73 | 2 | 4 |
6 | 8 | -0.04 | 165 | 15.42 | 303 | 771 | 4.12 / 100.50 | 2 | 7 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 28 | 15.38 | 472 | 203 | 0.20 / 92.03 | 2 | 3 |
2 | 7 | 2004.44 | 53 | 15.23 | 3103 | 2505 | 2.71 / 94.54 | 2 | 3 |
3 | 13 | 975.56 | 16 | 15.27 | 1717 | 419 | 3.13 / 94.96 | 2 | 3 |
4 | 13 | 386.36 | 16 | 15.38 | 896 | 220 | 3.35 / 95.18 | 2 | 3 |
5 | 13 | 56.16 | 16 | 15.44 | 398 | 98 | 3.45 / 95.28 | 2 | 4 |
6 | 8 | -0.08 | 165 | 15.42 | 301 | 766 | 4.21 / 96.04 | 2 | 8 |
7 | 14 | -0.08 | 75 | 15.38 | 296 | 341 | 4.55 / 96.38 | 3 | 11 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.64 | 28 | 15.37 | 483 | 208 | 0.21 / 87.83 | 2 | 2 |
2 | 7 | 2005.96 | 53 | 15.26 | 3121 | 2524 | 2.73 / 90.36 | 2 | 2 |
3 | 13 | 858.64 | 16 | 15.30 | 1573 | 385 | 3.12 / 90.74 | 2 | 3 |
4 | 13 | 425.40 | 16 | 15.37 | 949 | 233 | 3.35 / 90.97 | 2 | 3 |
5 | 13 | 63.40 | 16 | 15.45 | 408 | 101 | 3.45 / 91.08 | 2 | 3 |
6 | 8 | 0.32 | 165 | 15.43 | 296 | 754 | 4.20 / 91.83 | 2 | 5 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 28 | 15.38 | 452 | 195 | 0.19 / 83.64 | 2 | 3 |
2 | 7 | 2006.04 | 52 | 15.25 | 3104 | 2461 | 2.66 / 86.10 | 2 | 2 |
3 | 13 | 990.72 | 16 | 15.27 | 1747 | 427 | 3.08 / 86.53 | 2 | 3 |
4 | 13 | 407.36 | 16 | 15.38 | 932 | 229 | 3.31 / 86.76 | 2 | 3 |
5 | 13 | 61.28 | 16 | 15.45 | 408 | 101 | 3.41 / 86.86 | 2 | 3 |
6 | 8 | -0.20 | 165 | 15.41 | 302 | 768 | 4.18 / 87.62 | 2 | 8 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.84 | 28 | 15.38 | 482 | 208 | 0.21 / 79.51 | 2 | 3 |
2 | 7 | 2004.52 | 53 | 15.25 | 3105 | 2510 | 2.72 / 82.02 | 2 | 2 |
3 | 13 | 870.08 | 16 | 15.30 | 1579 | 387 | 3.10 / 82.40 | 2 | 3 |
4 | 13 | 326.20 | 16 | 15.40 | 809 | 199 | 3.30 / 82.60 | 2 | 3 |
5 | 13 | 50.80 | 16 | 15.46 | 386 | 95 | 3.40 / 82.70 | 2 | 4 |
6 | 8 | 0.20 | 165 | 15.43 | 293 | 746 | 4.14 / 83.44 | 2 | 7 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.32 | 28 | 15.38 | 473 | 204 | 0.20 / 75.28 | 2 | 3 |
2 | 7 | 2006.80 | 53 | 15.25 | 3111 | 2514 | 2.72 / 77.79 | 2 | 2 |
3 | 13 | 979.12 | 16 | 15.28 | 1732 | 423 | 3.14 / 78.22 | 2 | 3 |
4 | 13 | 394.36 | 16 | 15.39 | 904 | 223 | 3.36 / 78.44 | 2 | 3 |
5 | 13 | 58.48 | 16 | 15.47 | 397 | 98 | 3.46 / 78.54 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.44 | 298 | 759 | 4.22 / 79.30 | 2 | 6 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.24 | 28 | 15.38 | 476 | 205 | 0.20 / 71.03 | 2 | 3 |
2 | 7 | 2004.40 | 54 | 15.24 | 3112 | 2561 | 2.77 / 73.59 | 2 | 2 |
3 | 13 | 974.76 | 16 | 15.28 | 1726 | 422 | 3.19 / 74.01 | 2 | 2 |
4 | 13 | 384.00 | 16 | 15.38 | 896 | 220 | 3.41 / 74.23 | 2 | 3 |
5 | 13 | 57.52 | 16 | 15.45 | 398 | 98 | 3.51 / 74.33 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.43 | 294 | 749 | 4.26 / 75.08 | 2 | 4 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.40 | 28 | 15.39 | 470 | 203 | 0.20 / 66.81 | 2 | 3 |
2 | 7 | 2008.72 | 53 | 15.26 | 3117 | 2521 | 2.72 / 69.33 | 2 | 2 |
3 | 13 | 865.00 | 16 | 15.30 | 1580 | 387 | 3.11 / 69.72 | 2 | 3 |
4 | 13 | 431.12 | 16 | 15.37 | 967 | 238 | 3.35 / 69.96 | 2 | 3 |
5 | 13 | 62.04 | 16 | 15.45 | 407 | 101 | 3.45 / 70.06 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.43 | 299 | 761 | 4.21 / 70.82 | 2 | 5 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 28 | 15.39 | 456 | 196 | 0.20 / 62.60 | 2 | 3 |
2 | 7 | 2009.04 | 53 | 15.25 | 3118 | 2520 | 2.72 / 65.12 | 2 | 2 |
3 | 13 | 859.76 | 18 | 15.29 | 1560 | 429 | 3.15 / 65.55 | 2 | 3 |
4 | 13 | 278.48 | 18 | 15.41 | 737 | 204 | 3.35 / 65.75 | 2 | 3 |
5 | 13 | 30.40 | 18 | 15.46 | 356 | 99 | 3.45 / 65.85 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.43 | 298 | 759 | 4.21 / 66.61 | 2 | 6 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 28 | 15.39 | 454 | 196 | 0.20 / 58.40 | 2 | 3 |
2 | 7 | 2005.72 | 53 | 15.26 | 3115 | 2519 | 2.71 / 60.92 | 2 | 2 |
3 | 13 | 849.08 | 18 | 15.31 | 1549 | 427 | 3.14 / 61.35 | 2 | 2 |
4 | 13 | 274.24 | 18 | 15.42 | 731 | 203 | 3.34 / 61.55 | 2 | 3 |
5 | 13 | 30.96 | 18 | 15.47 | 356 | 99 | 3.44 / 61.65 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.44 | 296 | 754 | 4.20 / 62.40 | 2 | 6 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.04 | 28 | 15.40 | 472 | 204 | 0.20 / 54.16 | 2 | 3 |
2 | 7 | 2004.60 | 53 | 15.25 | 3099 | 2505 | 2.71 / 56.67 | 2 | 2 |
3 | 13 | 974.60 | 18 | 15.28 | 1721 | 473 | 3.18 / 57.14 | 2 | 3 |
4 | 13 | 249.72 | 18 | 15.42 | 691 | 192 | 3.37 / 57.33 | 2 | 3 |
5 | 13 | 51.84 | 18 | 15.46 | 388 | 108 | 3.48 / 57.44 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.43 | 300 | 764 | 4.25 / 58.21 | 2 | 9 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.16 | 28 | 15.41 | 467 | 202 | 0.20 / 49.94 | 2 | 3 |
2 | 7 | 2007.64 | 53 | 15.26 | 3115 | 2519 | 2.72 / 52.46 | 2 | 2 |
3 | 13 | 861.60 | 18 | 15.32 | 1570 | 433 | 3.15 / 52.90 | 2 | 3 |
4 | 13 | 286.40 | 18 | 15.42 | 753 | 209 | 3.36 / 53.11 | 2 | 3 |
5 | 13 | 34.04 | 18 | 15.47 | 362 | 101 | 3.46 / 53.21 | 2 | 3 |
6 | 8 | -0.12 | 165 | 15.44 | 296 | 754 | 4.22 / 53.96 | 2 | 9 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.92 | 27 | 15.39 | 468 | 194 | 0.19 / 45.71 | 2 | 3 |
2 | 7 | 2007.08 | 53 | 15.27 | 3113 | 2519 | 2.71 / 48.23 | 2 | 2 |
3 | 13 | 978.44 | 18 | 15.30 | 1728 | 476 | 3.19 / 48.70 | 2 | 2 |
4 | 13 | 247.96 | 18 | 15.45 | 688 | 191 | 3.38 / 48.90 | 2 | 3 |
5 | 13 | 29.76 | 18 | 15.48 | 348 | 97 | 3.48 / 48.99 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.45 | 294 | 749 | 4.23 / 49.74 | 2 | 5 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 27 | 15.41 | 446 | 186 | 0.19 / 41.52 | 2 | 3 |
2 | 7 | 2003.64 | 53 | 15.28 | 3109 | 2518 | 2.70 / 44.03 | 2 | 2 |
3 | 13 | 856.16 | 18 | 15.32 | 1559 | 430 | 3.13 / 44.46 | 2 | 3 |
4 | 13 | 280.96 | 18 | 15.44 | 738 | 205 | 3.34 / 44.67 | 2 | 3 |
5 | 13 | 30.44 | 18 | 15.48 | 351 | 98 | 3.44 / 44.77 | 2 | 3 |
6 | 8 | -0.12 | 165 | 15.44 | 294 | 749 | 4.19 / 45.51 | 2 | 6 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 27 | 15.40 | 472 | 196 | 0.20 / 37.33 | 2 | 3 |
2 | 7 | 2006.16 | 53 | 15.28 | 3109 | 2518 | 2.71 / 39.85 | 2 | 2 |
3 | 13 | 852.68 | 18 | 15.32 | 1554 | 429 | 3.14 / 40.28 | 2 | 3 |
4 | 13 | 279.92 | 18 | 15.44 | 736 | 205 | 3.35 / 40.48 | 2 | 3 |
5 | 13 | 33.44 | 18 | 15.48 | 357 | 99 | 3.45 / 40.58 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.45 | 293 | 747 | 4.19 / 41.33 | 2 | 10 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.64 | 27 | 15.41 | 474 | 197 | 0.20 / 33.12 | 2 | 3 |
2 | 7 | 2003.84 | 53 | 15.28 | 3108 | 2517 | 2.71 / 35.64 | 2 | 2 |
3 | 13 | 855.52 | 18 | 15.33 | 1553 | 429 | 3.14 / 36.07 | 2 | 3 |
4 | 13 | 283.68 | 18 | 15.44 | 739 | 205 | 3.35 / 36.27 | 2 | 3 |
5 | 13 | 32.48 | 18 | 15.48 | 359 | 100 | 3.45 / 36.37 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.45 | 299 | 762 | 4.21 / 37.14 | 2 | 7 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.92 | 27 | 15.40 | 477 | 198 | 0.20 / 28.94 | 2 | 3 |
2 | 7 | 2007.20 | 53 | 15.28 | 3112 | 2520 | 2.72 / 31.46 | 2 | 2 |
3 | 13 | 848.52 | 18 | 15.33 | 1545 | 426 | 3.14 / 31.88 | 2 | 3 |
4 | 13 | 271.84 | 18 | 15.44 | 721 | 200 | 3.35 / 32.08 | 2 | 3 |
5 | 13 | 29.28 | 18 | 15.48 | 347 | 97 | 3.44 / 32.18 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.45 | 293 | 747 | 4.19 / 32.93 | 2 | 9 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 27 | 15.41 | 467 | 194 | 0.19 / 24.75 | 2 | 3 |
2 | 7 | 2003.40 | 53 | 15.28 | 3102 | 2512 | 2.71 / 27.26 | 2 | 2 |
3 | 13 | 852.36 | 18 | 15.33 | 1550 | 428 | 3.13 / 27.69 | 2 | 3 |
4 | 13 | 274.56 | 18 | 15.43 | 726 | 202 | 3.34 / 27.89 | 2 | 3 |
5 | 13 | 26.24 | 18 | 15.48 | 344 | 96 | 3.43 / 27.99 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.44 | 294 | 749 | 4.18 / 28.74 | 2 | 8 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.44 | 26 | 15.40 | 471 | 189 | 0.19 / 20.54 | 2 | 3 |
2 | 3 | 1050.36 | 1 | 15.44 | 1907 | 29 | 0.22 / 20.57 | 2 | 2 |
3 | 7 | 2006.12 | 53 | 15.30 | 3100 | 2514 | 2.73 / 23.09 | 2 | 2 |
4 | 13 | 859.56 | 18 | 15.33 | 1550 | 428 | 3.16 / 23.51 | 2 | 3 |
5 | 13 | 269.36 | 18 | 15.45 | 716 | 199 | 3.36 / 23.71 | 2 | 3 |
6 | 13 | 25.84 | 18 | 15.48 | 340 | 95 | 3.45 / 23.81 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.46 | 293 | 747 | 4.20 / 24.56 | 2 | 12 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.08 | 25 | 15.42 | 470 | 181 | 0.18 / 15.80 | 2 | 3 |
2 | 10 | 1024.00 | 2 | 15.39 | 1836 | 57 | 0.24 / 15.86 | 2 | 2 |
3 | 7 | 2003.80 | 75 | 15.04 | 3055 | 3446 | 3.68 / 19.30 | 2 | 2 |
4 | 13 | 309.24 | 18 | 15.42 | 772 | 214 | 3.90 / 19.52 | 2 | 3 |
5 | 13 | 18.12 | 18 | 15.49 | 327 | 91 | 3.99 / 19.61 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.45 | 293 | 747 | 4.74 / 20.36 | 2 | 9 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.92 | 26 | 15.42 | 465 | 186 | 0.19 / 12.05 | 2 | 3 |
2 | 7 | 1507.52 | 74 | 15.18 | 2394 | 2689 | 2.88 / 14.74 | 2 | 3 |
3 | 13 | 118.40 | 18 | 15.47 | 489 | 136 | 3.01 / 14.87 | 2 | 3 |
4 | 8 | 0.16 | 165 | 15.46 | 293 | 747 | 3.76 / 15.62 | 2 | 6 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 25 | 15.45 | 466 | 180 | 0.18 / 8.27 | 2 | 3 |
2 | 7 | 1519.64 | 74 | 15.18 | 2408 | 2705 | 2.88 / 10.98 | 2 | 3 |
3 | 13 | 126.12 | 18 | 15.48 | 499 | 139 | 3.02 / 11.11 | 2 | 3 |
4 | 8 | 0.16 | 165 | 15.47 | 292 | 745 | 3.77 / 11.86 | 2 | 8 |
Average= | 2.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.92 | 26 | 15.47 | 474 | 191 | 0.19 / 4.75 | 2 | 3 |
2 | 7 | 1369.20 | 74 | 15.25 | 2211 | 2495 | 2.69 / 7.25 | 2 | 3 |
3 | 13 | 25.16 | 18 | 15.53 | 338 | 94 | 2.78 / 7.34 | 2 | 3 |
4 | 8 | 0.04 | 165 | 15.50 | 292 | 747 | 3.53 / 8.09 | 2 | 6 |
Average= | 2.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 23 | 15.60 | 427 | 153 | 0.15 / 1.78 | 3 | 3 |
2 | 10 | 1026.20 | 3 | 15.47 | 1837 | 85 | 0.24 / 1.86 | 2 | 2 |
3 | 7 | 1006.88 | 74 | 15.33 | 1721 | 1952 | 2.19 / 3.81 | 2 | 3 |
4 | 8 | 0.00 | 165 | 15.52 | 293 | 750 | 2.94 / 4.56 | 2 | 7 |
Average= | 2.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 140.12 | 22 | 15.72 | 463 | 160 | 0.16 / 0.16 | 3 | 3 |
2 | 7 | 154.48 | 75 | 15.69 | 473 | 557 | 0.72 / 0.72 | 3 | 3 |
3 | 8 | 0.24 | 240 | 15.66 | 241 | 906 | 1.62 / 1.62 | 3 | 13 |
Average= | 1.62 (KJ/cycle) |